InCarrier Fact Sheet

advertisement
InCarrier™8 Loader / Unloader
High parallel test for singulated packages >>
the Facts >
Solution for
> loader and unloader in one machine
> simultaneous operation with up to 8 k uph on
both systems
> flexible setup with up to 2 loading and 6
unloading modules
> standard SEMI mapping interface G84 or
E142
> integrated loading quality and carrier damage
control
> leaded and leadless devices
> all SO, QFN and BGA packages with
a device pitch down to 0.35 mm
ASIA
Singapore, Tel.: +65-6408-8408
customer.relations@Xcerra.com
EUROPE
Germany, Tel.: +49(0)8031-406-0
customer.relations@Xcerra.com
Applications >
>
>
>
>
>
>
consumer
automotive and power devices
RF and communication
logic, analog and microcontrollers
flash memory
MEMS test and calibration
NORTH AMERICA
USA (Milpitas, CA), Tel.: +1-408-635-4300
customer.relations@Xcerra.com
InCarrier™8 Loader / Unloader
High parallel test for singulated packages >>
1
Base System
5
Unloader
1.1
•
•
•
2 in 1:
InCarrier Loader and InCarrier Unloader integrated in one system
Loader & Unloader can be operated in parallel @ full performance
User Interface: 2 Displays with 17” Touch Screens
5.1
•
Max. number of Unloading modules in the system
Depending on kind of modules
1.2
•
Base system Options:
Dampener to reduce vibrations into a raised testfloor
1.3
•
Host interface:
SECS GEM G84 or File-based Map Handling
5.2
•
•
•
•
•
Available Unloading modules
Auto Tray Unloader (max. capacity: 30 Jedec trays)
Manual Tray Unloader (1 Tray)
Bulk Unloader
Metal Magazine Unloader (2 Magazines / Module)
Manual Tube Unloader (4 Tubes)
1.4
•
•
Options:
Internal vacuum pumpe
InSite connection
5.3
•
•
Carrier Inspections:
Pocket full inspection (incoming carrier)
Spring damage inspection (outgoing carrier)
2
Carriers / Packages
5.4
•
Cassette capacity:
Single Slotted Cassette Loader for cassettes with 235mm max height
2.1
•
•
Carrier size:
Min: 215 x 63mm
Max: 300 x 100mm
5.5
•
Carrier Traceability:
Data Matrixcode (ECC 200) on Carrier
2.2
•
•
Device types:
QFN, MLF, WLP, SO, BGA, SOT, …
Pitch down to 0,35mm
5.6
•
Options:
+/- 90° rotation of devices
6
Performance
3
Conversion
3.1
•
•
Package Style Conversion:
conversion time dependent on I/O-Modules (1 – 6 hrs / Module)
only 1 person necessary
6.1
•
•
•
Throughput Loader:
8000 uph. @ carriers with 144 devices or more
4000 uph @ carriers with 60 devices
Throughput might be limited by input medium (e.g. Manual Tube
Operation)
3.2
•
Adjustment/ Calibration after Conversion:
the system provides semi-automatic adjustment
4
Loader
6.2
•
•
•
4.1
•
Max. number of Loading modules in the system
Two: 1 x Tray and 1 x Bowl or Tube
Throughput Unloader:
8000 uph. @ carriers with 144 devices or more
4000 uph. @ carriers with 60 devices
Throughput might be limited by output medium (e.g. Manual Tube
Operation)
4.2
•
•
•
Available Loading modules
Auto Tray Loader (max. capacity: 30 Jedec trays)
Bowl Feeder (max device size: 7x7 mm)
Manual Tube Loader (4 Tubes)
6.3
•
Jam Rate:
1/3000 devices
7
Facility requirements
4.3
•
•
•
Carrier Inspections:
Pocket empty inspection (incoming carrier)
Spring damage inspection (incoming carrier)
Clamping inspection of devices (outgoing carrier)
7.1
•
Voltage:
3 x 208 – 480V, 50-60Hz
4.4
•
Cassette capacity:
Single Slotted Cassette Loader for cassettes with 235mm max
height
4.5
•
Carrier Traceability:
Data Matrix Code (ECC 200) on Carrier
4.6
•
Options:
+/- 90° rotation of devices
7.2 Compressed air:
•
5 – 10 bar
7.4
•
System dimension:
2,0m x 2,2m x 1,9m (WxDxH) (w/o signal tower)
7.5
•
System weight:
1600 kg
8
Compliance and Standards
8.1
•
Compliant to:
CE
8.2
•
Strip Mapping Interface:
SEMI standard SECS/GEM G84 or E142
8.3
•
Clean Room Requirements
class 8 semiconductor testing area
All performance figures such as MTBF, MTBA, Uptime, Yield , Jam Rate, Life Span, Cleaning Cycles etc. can vary with specific package type, test program and / or specific application environment. They assume that only original Multitest
spare and consumable parts are used, recommended maintenance intervals and procedures are respected, operators/maintenance technicians have successfully participated in formal equipment training by Multitest to the appropriate level,
and only Multitest approved software is used on the systems. Multitest assumes no warranty or liability if any of these requirements is not met. All listed data are for information only. For binding specification please contact your sales person
ASIA
Singapore, Tel.: +65-6408-8408
customer.relations@Xcerra.com
EUROPE
Germany, Tel.: +49(0)8031-406-0
customer.relations@Xcerra.com
NORTH AMERICA
USA (Milpitas, CA), Tel.: +1-408-635-4300
customer.relations@Xcerra.com
FSInCarrier_02_2016
7.3 Vacuum:
•
External vacuum or internal vacuum pump (option)
Download