Submittal Package Riley Construction Company, Inc. 5301 99th Avenue Kenosha, Wisconsin 53144 Project: 61672-900 - Gateway Mortgage Corporation 6441 Green Bay Road Kenosha, Wisconsin 53144 34 - Electrical Control Devices SPEC SECTION: 26 00 00 - Electrical LINK TO PROCORE: View CREATED DATE: 06/27/2016 CREATED BY: Kelly Hoffman (Riley Construction Company, Inc.) DESCRIPTION: ATTACHMENTS: ISSUE DATE: 7/1/2016 RCCI REVIEWER: Chad Parker RECEIVED FROM: Jennifer Levin (Valiant Electric, Inc.) RETURN DATE: BALL IN COURT: Mark Molinaro (Partners In Design Architects, Inc. - Kenosha) COPIES TO: Kelly Hoffman (Riley Construction Company, Inc.) File Copy (Riley Construction Co, Inc. - Milwaukee) Chad Parker (Riley Construction Company, Inc.) Garrick Palay (Riley Construction Company, Inc.) Vinnie Chambers (Riley Construction Company, Inc.) SUBMITTALS Title 26 00 00-1.0: PD: Electrical Control Devices Spec Section 26 00 00 - Electrical Type Status Due Date Product Data Pending Approval 07/08/2016 Riley Construction Company, Inc. Page 1 of 2 Printed On: 07/01/2016 09:58 AM EXHIBIT A SUBMITTAL COVER SHEET – SHOP DRAWINGS, PRODUCT DATA, SAMPLES Date of Submittal: Project Name: Contractor’s Name: Subcontractor’s Name: Supplier’s Name: Specification Sections: Submittal No/Rev No: Description: 07/01/2016 Gateway Mortgage Riley Construction Company Inc. Valient Electric, Inc. Submittal Packets/Drawings Procore Architect’s Project No: 61672-900 Contractor’s Project No: Subcontractor’s Project No: Supplier’s Project No: 26 00 00 34/0 Electrical Control Devices Subcontractor/Supplier Review Stamp (Optional) Contractor’s Review Stamp (Mandatory) Reviewed Incorporate Any Correction Noted Revise and Resubmit Checking is only for conformance with the design concept of the Project and compliance with the information given in the Contract Document. Submitting contractor is responsible for confirming dimensions and correlation at the job site, for information that pertains solely to the fabrication processes or to techniques of construction, and for coordination of the work of all trades. RILEY CONSTRUCTION COMPANY, INC. By_____________________________________ Consulting Engineer’s Review Stamp □ Submittal Review Sheet Attached Contractor & Consultant Submittal Procedures 122702 Architect’s Review Stamp Lutron Proposal Submitted To: Project Name: Location: CED Interstate Kenosha Gateway Mortgage Kenosha, WI Manufacturer: PO# Submitted By: Date: Lutron 3654-JES941190D Engineered Representation Inc. 06-21-2016 A/E: Please confirm colors off attached color chart. Submittal Specification Sheets Gateway Mortgage Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 1 04.16.15 Maestro® 0 – 10 V Dimmer Sensor Lutron® Maestro® 0 – 10 V Dimmer Sensors are lighting controls with passive infrared sensors that automatically control the lights in an area. These sensors detect heat from occupants moving within an area to determine when the space is occupied. The Maestro® 0 – 10 V Dimmer Sensor combines a Maestro® 0 – 10 V Dimmer with an occupancy or vacancy Sensor. Features • Controls 0 – 10 V- electronic fluorescent ballasts or LED driver load types* • Passive infrared motion detection with exclusive Lutron® XCTTM Technology for fine motion detection • 180° sensor field-of-view • Up to 30 ft × 30 ft (9 m × 9 m) [900 ft2 (81 m2)] major motion coverage and 20 ft × 20 ft (6 m × 6 m) [400 ft2 (36 m2)] minor motion coverage • Occupancy version can be set to auto-on/auto-off or manual-on/auto-off • Vacancy version available to meet CA Title 24 requirements • Adjustable timeout (1, 5, 15, or 30 minutes) • Adjustable settings for auto-on light level (occupied level): 100%, 50%, last light level, or locked preset light level • Adjustable sensitivity level: High, Med, Low, Min • Off warning fades lights to off over a period of 10 seconds • Advanced Maestro® dimmer features available (locked preset, fade-to-on, and fade-to-off, etc.) • Adaptive switching algorithm for extended relay life • Smart ambient light detection (ALD) • All models have single pole and 3-way capability • Works with a single standard mechanical 3-way switch or up to 9 companion switches (MA-AS or MSC-AS)* • High-end trim and low-end trim to adjust maximum and minimum light levels • Selectable dimming curve—linear or square law • Miswire and incompatible load alert * When using with standard mechanical 3-way switch, some rewiring is required. Not compatible with MA-R. Models Available Model Number1 Description MS-Z101-XX Occupancy/vacancy Single-pole/multi-location MS-Z101-V-XX Vacancy Single-pole/ multi-location 1 2 Sensor Operation Auto-on/auto-off or manual-on/auto-off Manual-on/auto-off ONLY Maximum Capacity 8 A electronic fluorescent ballasts or LED driver2 8 A electronic fluorescent ballasts or LED driver2 XX in model number represents color/finish code. Works with all ballasts and drivers that provide a current source compliant to IEC 60629 Annex E.2. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 1 Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 2 04.16.15 Specifications Regulatory Approvals • UL Listed to U.S. and Canadian safety requirements • Title 20/24 certified lighting control device – Complies with Title 20 and Title 24 Section 110.9 Power • Operating voltage: 120 – 277 V~ 50/60 Hz Loads • 8 A 0 –10 V- electronic fluorescent ballasts or LED drivers • Works with all ballasts and drivers that provide a current source compliant to IEC 60629 Annex E.2, and whose inrush current does not exceed NEMA410 standards for electronic ballast/driver loads of 8 A steady state current. • 50 mA max sink current • Controls up to 25 ballasts or drivers (IEC 60929 Annex E.2 requires the ballast /driver to limit the current draw to 2.0 mA maximum) Environment • Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% – 90% humidity, non-condensing; indoor use only Warranty • 5 Year Limited Warranty For additional Warranty information, please visit: www.lutron.com/TechnicalDocumentLibrary/Sensor_ Warranty.pdf Additional Information on Sensors • For single-circuit PIR Maestro® occupancy sensor switch models, refer to Lutron® P/N 369666 • For Maestro® occupancy sensor C•L® dimmer models, refer to Lutron® P/N 369748 • For dual-circuit PIR Maestro® occupancy sensor switch, refer to Lutron® P/N 369758 • For dual technology occupancy sensor switch models, refer to Lutron® P/N 369773 • For more information, please see www.lutron.com/occvacsensors • Lutron Technical Hotline: 1.800.523.9466. Select Design Feature Details • Selectable dimming curve—linear or square law. Drivers exist with linear response and some exist with square law response. By providing a selectable dimming curve from the 0 –10 V Dimmer Sensor, the user is able to choose his/her preferred response for optimized dimming performance. • Miswire and incompatible load alert. The user will receive a visual alert when the product’s 0 –10 Vcontrol wires are incorrectly connected or an incompatible load is detected. In these conditions, the product will still function as a switch. Refer to Application Note 048536 for more details. • Fade-to-On and Fade-to-Off. Key Design Features • • • • • Dimmer On a single-tap, lights fade ON or OFF On a double-tap, lights go to full ON Light levels can be fine-tuned by pressing and holding the dimming rocker until the desired light level is reached High-end trim (adjust maximum light level that can be achieved, for energy savings) Low-end trim (adjust minimum light level that can be dimmed down, to prevent flickering lights) S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 2 Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 3 04.16.15 Load Type and Capacity with Multi-Location Neutral Vacancy 0 –10 V- Voltage/Load Type/Maximum Load Minimum 3-Way Mechanical with Accessory 1,2 3 Connection Only Current (Anywhere in gang) Load Switch Switch 50 mA 120 – 277 V~ Electronic fluorescent MS-Z101Optional — 0A P P max sink ballast or LED drivers, 8 A 50mA MS-Z101-V Optional 0A P max sink 120 V~ Fan 4.4 A (1/6 HP)4 P P Control 1 The 0 –10 V- control wires are not to exceed 250 ft (76.2 m) in length, and must have a size of no less than 20 AWG (0.75 mm2). The 0 –10 V- wires must be installed as Class One per NEC® or local jurisdiction. 3 Dimmer Sensor load type: Designed for use with permanently installed electronic fluorescent ballast or LED driver lighting loads. Do not install dimmers to control receptacles or motor-operated appliances. 4 When controlling light and fan loads simultaneously on a single circuit, maximum load capacity per circuit is 4.4 A at 120 V~. 2 Notes: • Ground or neutral is required for product to function. If neither is present, consult a licensed electrician. • When power is applied, the Dimmer Sensor can be manually turned on or off after the first 10 seconds and will automatically control the load after 2 minutes. • Works with all ballasts and drivers that provide a current source compliant to IEC 60929 Annex E.2. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 3 Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 4 04.16.15 Custom Settings (default settings shown in • • • • : Timeout 30 min 15 min 5 min 1 min • • • • Mode: Sensor Modes Lights automatically turn off in all sensor modes Occ: Occupancy mode (No ALD) Lrn: Occupancy with learning ALD mode Fixd: Occupancy with fixed ALD mode Vac: Vacancy mode (No ALD) bold ) PIR: Passive Infrared Sensitivity • Hi •Med •Low •Min • • • • Fade On Rate 15 sec 5 sec 2.5 sec 0.75 sec • • • • Fade Off Rate 15 sec 5 sec 2.5 sec 0.75 sec • • • • • Additional Settings Fixed ALD Light Level •Hi •Med • Low * •Min * Low is the default setting for any sensor that is set by the user to “Occupancy with fixed ALD mode” Manual Off-While-Occupied • Enabled •Disabled Walk-Thru Mode •Enabled • Disabled Occupied Level A programmable setting that determines the light level the Dimmer Sensor will turn on to, once occupancy has been detected • 100% •50% • Preset Level – When the Occupied Level is set to Preset Level, the Dimmer Sensor will automatically and manually turn on to the selected Preset Level. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Preset Level** Locked (High range) Locked (Med range) Locked (Low range) Locked (Min range) Unlocked – When the Preset Level is set to a locked level, the Dimmer Sensor will turn ON to the predetermined “locked” level with a single tap of the Tap button. – When the Preset Level is set to unlocked, a single tap of the Tap button will turn the Dimmer Sensor ON to the light level to which it was adjusted the last time the light was on. • • • • Low-End Trim** High range Med range Low range Min range • • • • High-End Trim** High range Med range Low range Min range ** Setting is fully variable within each range. Page 4 Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 5 04.16.15 Custom Settings: Details (default settings shown in bold ) Ambient Light Detection (ALD) mode Lights turn on only when natural light in the room is below the set threshold. • Enabled – Learning: The ambient light threshold adjusts to the user’s preference via manual interaction with the Dimmer Sensor. – Fixed: Choose a fixed ALD light level from 4 pre‑set options: High, Medium, Low, Minimum. • Disabled Fade-On Rate The time required for the lights to reach the preset light level when the tap button is pressed. Manual Off-While-Occupied Options • Enabled – When the Dimmer Sensor is manually turned off, the sensor switch will not turn the lights back on automatically while the room is occupied. – Once the room is vacated, the Auto-On feature returns to normal operation after the timeout period has expired. – This may be the preference in conference rooms or classrooms while viewing presentations. This feature requires motions to keep the lights off. • Disabled – When the Dimmer Sensor is manually turned off, the Auto-On feature will return to normal operation after 25 seconds. – This may be the preference in a restroom if the user always wants the lights to turn on upon entering and the lights to turn off when the room is vacant. High-End trim Highest achievable light level to which the Dimmer Sensor can be adjusted. Fade-Off Rate The time required for the lights to turn off (from the ON state) when the tap button is pressed. Low-End Trim Lowest achievable light level to which the Dimmer Sensor can be adjusted. Walk-Thru Mode • Enabled* – If motion is not detected within 3 minutes after initial occupancy, the lights will turn off after 3 minutes, instead of the current timeout. – This setting may be the preference in commercial applications where personnel may briefly trigger sensors during non-working hours. • Disabled – When motion is detected, the lights will ALWAYS remain on for the entire timeout duration regardless of the duration of occupancy detection. * 1 minute timeout would be overridden if walk-thru mode is also Enabled S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 5 Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 6 04.16.15 Maestro® 0 – 10 V Dimmer Sensor Placement and Operation • The ability of the Dimmer Sensor to detect motion requires line-of-sight of room occupants. The Dimmer Sensor must have an unobstructed view of the room. • Hot objects and moving air currents can affect the performance of the Dimmer Sensor. For best performance, the Dimmer Sensor should be mounted at least 4 ft (1.2 m) away from HVAC vents and light bulbs. • The performance of the Dimmer Sensor depends on a temperature differential between the ambient room temperature and that of room occupants. Warmer rooms may reduce the ability of the Dimmer Sensor to detect occupants. NEMA WD7 Test Grid Coverage (High Sensitivity Setting) Horizontal Beam Diagram (For Reference Only) Major motion coverage: 900 ft2 (81 m2) Minor motion coverage: 400 ft2 (36 m2) 15 ft (4.5 m) 15 ft (4.5 m) 10 ft (3 m) 10 ft (3 m) 5 ft (1.5 m) 5 ft (1.5 m) 0 0 5 ft (1.5 m) 5 ft (1.5 m) 10 ft (3 m) 10 ft (3 m) 15 ft (4.5 m) 15 ft (4.5 m) 0 5 ft (1.5 m) 10 ft (3 m) 15 ft (4.5 m) 20 ft (6 m) 25 ft (7.5 m) 30 ft (9m) Vertical Beam Diagram (For Reference Only) 4 ft (1.2 m) 0 10 ft (3 m) 20 ft (6 m) S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: 30 ft (9m) Page 6 Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 7 04.16.15 Dimensions Operation Measurements shown as: in (mm) Coopersburg, PA 800.523.9466 lutron.com Side View Front View TURN OFF POWER ARRETEZ LE COURANT DESCONECT LA CORRIENTE Up Tap button (tap on/off) Programming LEDs Raise Timeout button Sensor Mode button 411⁄16 (119) Sensor LED (behind lens) pulses during Test mode Alt 30 m 15 5 1 Alt button Lower PIR Mode Hi Med Low Min Occ Lrn Fixd Vac PIR sensitivity button PIR sensitivity lens 120 – 277 V~ 50 / 60 Hz 8A 215⁄16 (75) 5/16 (3) 11 ⁄8 (30) 1/8 (3) Mounting Wallbox Recommended dimensions: 3.5 in (89 mm) D × 3 in (76 mm) H × 2 in (51 mm) W Dimmer Sensor Wallplate Adapter/ Wallplate (sold separately) 30 15 5 1 Mounting screws e Mod Occ Lr n d Fix Vac S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Adapter mounting screws Page 7 Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 8 04.16.15 Wiring Installations with the Maestro® 0 – 10 V Dimmer Sensor In order to function, the 0 –10 V Dimmer Sensor must either have the green/yellow wire connected to ground, or, with the white sleeve covering the green/yellow wire, connect to neutral. Before installing wallplate, program all desired settings. Coopersburg, PA 800.523.9466 lutron.com TURN OFF POWER ARRETEZ LE COURANT DESCONECT LA CORRIENTE Up Alt 30 m 15 5 1 Mode Occ Lrn Fixd Vac PIR Hi Med Low Min Green/Yellow wire connects to ground Green/Yellow wire covered by white sleeve connects to neutral 120 – 277 V~ 50 / 60 Hz 8A Wiring: Single-Pole Installation Without Neutral Coopersburg, PA Line/Hot Black 120 – 277 V~ 50/60 Hz TURN OFF POWER ARRETEZ LE COURANT DESCONECT LA CORRIENTE 800.523.9466 lutron.com Black Up Alt 30 m 15 5 1 PIR Mode Hi Med Low Min Occ Lrn Fixd Vac Blue1 Gray (–) Purple (+) Gray (–) Purple (+) Gray (–) Purple (+) White Black White Black Gray (–) Purple (+) Gray (–) Purple (+) White Black White Black 120 – 277 V~ 50 / 60 Hz 8A Green Green/Yellow Ground Neutral With Neutral Coopersburg, PA Line/Hot Black 120 – 277 V~ 50/60 Hz TURN OFF POWER ARRETEZ LE COURANT DESCONECT LA CORRIENTE 800.523.9466 lutron.com Black Up Alt 30 m 15 5 1 Mode Occ Lrn Fixd Vac PIR Hi Med Low Min Blue1 Gray (–) Purple (+) 120 – 277 V~ 50 / 60 Hz 8A Green Ground Neutral 1 2 White2 When using controls in single location installations, cap the blue wire. Do not connect the blue wire to any other wiring or to ground. Green/Yellow wire covered by white sleeve connects to neutral. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 8 Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 9 04.16.15 Wiring: 3-Way Installation* with Standard Mechanical Switch** Without Neutral Blue1 Coopersburg, PA Line/Hot Black 120 – 277 V~ 50/60 Hz TURN OFF POWER ARRETEZ LE COURANT DESCONECT LA CORRIENTE 800.523.9466 lutron.com Up Black Alt 30 m 15 5 1 PIR Mode Hi Med Low Min Occ Lrn Fixd Vac Gray (–) Blue Gray (–) Purple (+) Purple (+) Gray (–) Purple (+) White Black White Black Gray (–) Purple (+) Gray (–) Purple (+) White Black White Black 120 – 277 V~ 50 / 60 Hz 8A Green Green/Yellow Ground Ground Neutral With Neutral Blue1 Coopersburg, PA Black Line/Hot 120 – 277 V~ 50/60 Hz TURN OFF POWER ARRETEZ LE COURANT DESCONECT LA CORRIENTE 800.523.9466 lutron.com Up Black Alt 30 m 15 5 1 Mode Occ Lrn Fixd Vac PIR Hi Med Low Min Blue Gray (–) Purple (+) 120 – 277 V~ 50 / 60 Hz 8A Green Ground Ground Neutral * ** 1 2 White2 One Dimmer Sensor can be installed in any location. Important: Some rewiring of 3-way mechanical switch is required. See page 10 for instructions. The length of the Blue wire (3-way wire) must not exceed 150 ft (45.72 m). Green/Yellow wire covered by white sleeve connects to neutral. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 9 Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 10 04.16.15 3-Way Retrofit Installation For retrofit 3-way installations, the mechanical switch needs to be rewired as shown in the diagram below after wiring the Dimmer Sensor. Otherwise, the 3-way installation will not work as expected. Single-pole mechanical switches may also be used in a 3-way installation with MS-Z101 and MS-Z101-V models. 1.Connect Ground: Ensure that the bare copper or green ground wire from the wallbox is connected to the green ground screw of the mechanical switch. 2.Tag circuit Common: Your 3-way mechanical switch should have three screw terminals, two of the same color, and one of a different color. Tag the wire that is connected to the screw terminal of a different color. 3.Identify the wire that matches the color of the wire you connected to the blue wire of the Maestro® Dimmer Sensor. Connect this wire to one of the two terminals of the same color. 4.Combine the tagged wire, the remaining wire, and the yellow jumper wire (included) using a wire connector. Connect the other end of jumper wire to the different color screw. Note: If the 0 –10 V Dimmer Sensor is first installed with a traditional 3-way mechanical switch and the mechanical switch is later replaced with a Maestro® Accessory Switch, the 0 –10 V Dimmer Sensor will need to be returned to factory default settings in order to function correctly. Traditional 3-Way Mechanical Switch Wiring Traveler Rewired to 3-Way Mechanical Switch Wiring with Dimmer Sensor Traveler Traveler (to Blue wire) Yellow Jumper wire (included) Common Different color screw Tagged wire (Common) Different color screw Traveler (to Black wire) Ground S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Ground Page 10 Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 11 04.16.15 Wiring: 120 V~ Multi-Location Installation* with Maestro® Accessory Switches Note: If the 0 –10 V Dimmer Sensor is first installed with a traditional 3-way mechanical switch and the mechanical switch is later replaced with a Maestro® Accessory Switch, the 0 –10 V Dimmer Sensor will need to be returned to factory default settings in order to function correctly. Without Neutral Blue1 Blue Blue Coopersburg, PA Line/Hot Black Brass Black Brass Black 120 V~ 50/60 Hz TURN OFF POWER ARRETEZ LE COURANT DESCONECT LA CORRIENTE 800.523.9466 lutron.com Up Black Gray (–) Alt 30 m 15 5 1 PIR Mode Hi Med Low Min Occ Lrn Fixd Vac MA-AS or MSC-AS MA-AS or MSC-AS Green Purple (+) Gray (–) Purple (+) 120 – 277 V~ 50 / 60 Hz 8A Green Ground Gray (–) Purple (+) White Black White Black Green Ground Green/Yellow Ground Neutral With Neutral Blue1 Blue Blue Coopersburg, PA Line/Hot Black Brass Black Brass 120 V~ 50/60 Hz Black TURN OFF POWER ARRETEZ LE COURANT DESCONECT LA CORRIENTE 800.523.9466 lutron.com Up Black Gray (–) Alt 30 m 15 5 1 Mode Occ Lrn Fixd Vac MA-AS or MSC-AS MA-AS or MSC-AS Green Ground PIR Hi Med Low Min Gray (–) Purple (+) Purple (+) Gray (–) Purple (+) White Black White Black 120 – 277 V~ 50 / 60 Hz 8A Green Ground Green White2 Ground Neutral * One Dimmer Sensor can be installed in any location. 1 The length of the Blue wire (3-way wire) must not exceed 150 ft (45.72 m). 2 Green/Yellow wire covered by white sleeve connects to neutral. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 11 Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 12 04.16.15 Wiring: 220–277 V~ Multi-Location Installation with Maestro® Accessory Switches Note: If the 0 –10 V Dimmer Sensor is first installed with a traditional 3-way mechanical switch and the mechanical switch is later replaced with a Maestro® Accessory Switch, the 0 –10 V Dimmer Sensor will need to be returned to factory default settings in order to function correctly. Without Neutral Blue1 Blue Blue Coopersburg, PA Line/Hot Black Red Black Red Black 220 – 277 V~ 50/60 Hz TURN OFF POWER ARRETEZ LE COURANT DESCONECT LA CORRIENTE 800.523.9466 lutron.com Up Black Gray (–) Alt 30 m 15 5 1 PIR Mode Hi Med Low Min Occ Lrn Fixd Vac MA-AS-277 or MSC-AS-277 MA-AS-277 or MSC-AS-277 Green Purple (+) Gray (–) Purple (+) Purple (+) 120 – 277 V~ 50 / 60 Hz 8A Green Ground Gray (–) White Black White Black Green Ground Green/Yellow Ground Neutral With Neutral Blue1 Blue Blue Coopersburg, PA Line/Hot Black Red Black Red 220 – 277 V~ 50/60 Hz Black TURN OFF POWER ARRETEZ LE COURANT DESCONECT LA CORRIENTE 800.523.9466 lutron.com Up Black Gray (–) Alt 30 m 15 5 1 Mode Occ Lrn Fixd Vac MA-AS-277 or MSC-AS-277 MA-AS-277 or MSC-AS-277 Green Ground PIR Hi Med Low Min Gray (–) Purple (+) Gray (–) Purple (+) Purple (+) White Black White Black 120 – 277 V~ 50 / 60 Hz 8A Green Ground Green White2 Ground Neutral * One Dimmer Sensor can be installed in any location. 1 The length of the Blue wire (3-way wire) must not exceed 150 ft (45.72 m). 2 Green/Yellow wire covered by white sleeve connects to neutral. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 12 Maestro® Maestro® 0–10 V Dimmer Sensor Sensor 369833b 13 04.16.15 Colors and Finishes Gloss Finishes A/E: Please confirm color. Satin Finishes White WH Ivory IV Hot HT Merlot MR Plum PL Turquoise TQ Almond AL Light Almond LA Taupe TP Eggshell ES Biscuit BI Snow SW Gray GR Brown BR Palladium PD Midnight MN Sienna SI Terracotta TC Greenbriar GB Bluestone BG Mocha Stone MS Goldstone GS Desert Stone DS Stone ST Limestone LS Sea Glass SG Black BL • Due to printing limitations, colors and finishes shown cannot be guaranteed to perfectly match actual product colors. • Color chip keychains are available for more precise color matching: – Gloss Finishes: DG-CK-1 – Satin Finishes: SC-CK-1 S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 13 Sensors LOS-CDT Series Occupancy Sensors 369653c 1 02.07.13 Dual Technology Ceiling Mount Sensor The LOS-CDT Series dual technology ceiling-mount sensors can integrate into LutronR systems or function as stand-alone controls using a LutronR power pack. The technology eliminates manual sensitivity and timer adjustments during installation and over the life of the product. Features • Intelligent, continually adapting sensor • Ultrasonic (US) combined with Passive Infrared (PIR) sensing provide high sensitivity, high noise immunity, and excellent false tripping immunity • Suited for complex environments that are difficult to control with single-technology sensors • Snap-locks to ceiling-mounted cover plate • Non-Volatile Memory: settings saved in protected memory are not lost during power outages • 500 ft( to 2000 ft( (46 m( to 186 m() coverage when mounted on an 8 ft to 12 ft (2.4 m to 3.7 m) ceiling • Affords choice of turning lights off or dimming to a preset level in the unoccupied state when integrated with a LutronR system. A/E: Please confirm correct color. Models Available Model Color Coverage Field of View 500 ft( (46 m() 180° 500 ft( (46 m() 180° 1000 ft( (93 m() 180° 1000 ft( (93 m() 180° 2000 ft( (186 m() 360° 2000 ft( (186 m() 360° LOS-CDT-500-WH LOS-CDT-500R-WH LOS-CDT-1000-WH LOS-CDT-1000R-WH LOS-CDT-2000-WH LOS-CDT-2000R-WH White White White White White White Self-Adaptive Feature The LOS-CDT Series sensors combine both Ultrasonic (US) motion detection for maximum sensitivity and Passive Infrared (PIR) motion detection for false triggering immunity. The self-adapting internal microprocessor analyzes the composite sum of both signals to eliminate time-consuming adjustments and callbacks found in non-intelligent sensors. S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 1 Sensors LOS-CDT Series Occupancy Sensors 369653c 2 02.07.13 Specifications Housing Regulatory Approvals •Rugged, high-impact, injection-molded plastic •Color-coded leads 6 in (15 cm) •ULR and cULR listed Power •Operating voltage: 20 – 24 V-, IEC PELV/NECR Class 2 •Operating current: 33 mA nominal •Control output: 20 – 24 V- active high logic control signal with short-circuit protection, open collector when unoccupied Environment •Temperature: 32 °F to 104 °F (0 °C to 40 °C) •Relative humidity: less than 95%, non-condensing • For indoor use only Timer Adjustment •Automatic mode: Continually adapting sensor automatically adjusts settings to the space •Manual mode: 8 to 30 minutes •Test mode: 8 seconds Adaptive Functions •Installation: 60 minutes •Learning: 4 weeks for response to error conditions, air current adaptation, and timer optimization •Post-learning occupancy periods —24 hour circadian occupancy periods learned —Weekly occupancy periods learned •Adjustments in post-learning period —Generally occupied periods (threshold = high-sensitivity mode) —Generally unoccupied periods (threshold = miser mode) Contact Rating (R Models only) •SPDT 500 mA rated at 24 V- isolated relay Photo Cell (R Models only) •Prevents light from turning on when there is sufficient natural light •Sensitivity: 0 lx to 1000 lx adjustable LED Lamp •Red: infrared motion detected •Green: ultrasonic motion detected Dimensions 1.4 in (38 mm) 4.5 in (114 mm) Front View Side View S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 2 Sensors LOS-CDT Series Occupancy Sensors 369653c 3 02.07.13 Wiring: System Control Power packs may be required when interfaced to LutronR lighting control systems. If more than 1 occupancy sensor is connected to the same input, a power pack is required. A maximum of 3 occupancy sensors can be connected to the same input. If more than 3 sensors are required per input, use one of the following models: LOS-CDT-500R-WH, LOS-CDT-1000R-WH, or LOS-CDT-2000R-WH. Power Supply Options LutronR Lighting Control System Power Pack Required? Digital microWATTT EcoSystemR Energi Savr NodeT GRAFIK 5000T/6000R/7000T No No No* No, when used with seeTouchR wallstations with occupancy sensor connections. Yes No* Yes No* No, when used with seeTouchR wallstations with occupancy sensor connections. No No* Yes Yes No, when used with seeTouchR wallstations with occupancy sensor connections. GRAFIK EyeR 3000/4000 GRAFIK EyeR QS HomeWorksR HomeWorksR QS LCP128T microWATTR QuantumR RadioRAR RadioRAR 2 Softswitch128R *S ome system components do not supply external power for occupancy sensors. Refer to individual product specifications for more information. S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 3 Sensors LOS-CDT Series Occupancy Sensors 369653c 4 02.07.13 Wiring: Stand-Alone Control 1 to 3 Sensors with Power Pack Line 120 / 277 / 347 V~ 60 Hz; 230 V~ 50 / 60 Hz Neutral Red (+20 – 24 V-) Blue* (signal) Power Pack Black (common) Black White Red Red Lighting Load NOTE: Maximum 3 occupancy sensors. Switching Multiple Loads with Auxiliary Power Packs Line 120 / 277 / 347 V~ 60 Hz 230 V~ 50 / 60 Hz Neutral Lighting Load Red Red Auxiliary Power Pack Red (+20 – 24 V-) Blue* (signal) Black (common) Power Pack Black White Red Red Lighting Load NOTE: Maximum of 3 devices total (occupancy sensors and auxiliary power packs) can be connected to a power pack. *Use gray wire for LOS-CDT-500R-WH, LOS-CDT-1000R-WH, and LOS-CDT-2000R-WH. S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 4 Sensors LOS-CDT Series Occupancy Sensors 369653c 5 02.07.13 Wiring Relay Model Option LOS-CDT-500R-WH, LOS-CDT-1000R-WH, and LOS-CDT-2000R-WH only Red (+20 – 24 V-) Lighting Control system* Gray (control: occupancy and photo cell signal) Blue: Cap off Black (common) Gray wire logic with photo cell active: Room First Occupied Light level During Occupancy Lights Light level Lights Below set value Turn on Falls below set value Turn on Above set value Remain off Moves above set value Remain on *May require power pack Yellow/White (NO) Black/White (NC) Blue/White (Relay, Common) Choose wire based on functionality): • Yellow/White: NO (normally open) Open: Unoccupied Closed: Occupied • Black/White: NC (normally closed) Open: Occupied Closed: Unoccupied Cap off unused wire. S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 5 Sensors LOS-CDT Series Occupancy Sensors 369653c 6 02.07.13 Installation Sensor Setup •Sensor setup is available as a service by Lutron. For more information see the Sensor Layout and Tuning service document (LutronR P/N 3601235). Sensor Placement •Mount the sensor so the grilles face the open portion of the room and are not facing a nearby wall, window, or other obstructing object. •Do not place sensor within 6 ft (1.8 m) of air vents, air handlers, windows, fans, etc., as this may cause false triggering. •If installing a 180° occupancy sensor (500 and 1000 models), place the sensor on the same wall as the doorway so that traffic in a hallway will not affect the sensor; otherwise, place in center of room. •Closely follow the diagrams shown concerning major and minor motion coverage. The sensor can detect major motion (e.g. person taking a half-step) at a greater distance than it can detect minor motion (e.g. writing at a desk or reading a book). •Decrease total coverage area by 15% for “soft” rooms (e.g. heavy draperies or thick carpeting). Range Diagrams 32 ft (9.8 m) 23 ft (7 m) 23 ft (7 m) 16 ft (4.9 m) 23 ft 32 ft (7 m) (9.8 m) 16 ft 23 ft (4.9 m) (7 m) 12 ft (3.7 m) 22 ft (6.7 m) 12 ft (3.7 m) 22 ft (6.7 m) LOS-CDT-500 LOS-CDT-1000 64 ft (19.5 m) 45 ft (13.7 m) Major motion detection (Ultrasonic) Minor motion detection (Ultrasonic) 23 ft 32 ft (7 m) (9.8 m) Major motion detection (Passive Infrared) Minor motion detection (Passive Infrared) LOS-CDT-2000 12 ft (3.7 m) 22 ft (6.7 m) S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 6 Sensors LOS-CDT Series Occupancy Sensors 369653c 7 02.07.13 Mounting Normal Mounting Mounting to Non-Standard Ceiling or Fixture Twist and lock threaded mounting post onto cover plate. Drill through ceiling tile with assembly, using cutter end of the threaded mounting post. Secure with washer and nut. Mount twist-lock cover plate using mounting screws, nuts, and washers (included). Drill/punch wire routing hole through ceiling tile at center of cover plate. 13/16 in (21 mm) Cutter end Wire Lengths Mounting Plate Dimensions 0.52 in (13.3 mm) 2.5 in (63 mm) 4.2 in (106.6 mm) Number of Sensors 1 2 3 1 2 1 Number of Auxiliary Power Packs 0 0 0 1 1 2 22 AWG 750 ft 375 ft 0.5 mm( 365 m 180 m 120 m 90 m 120 m 120 m 20 AWG 1200 ft 600 ft 400 ft 600 ft 400 ft 400 ft 0.75 mm( 730 m 240 m 365 m 240 m 365 m 18 AWG 2400 ft 1200 ft 800 ft 1200 ft 800 ft 800 ft Using the Infrared Mask Center Ceiling Mount (Mask blocks sensor seeing out doorway into hall) Job Number: 375 ft 250 ft 250 ft Typical Mask Patterns Corner Ceiling Mount (No mask needed) S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® 365 m 250 ft Conference Room Mask 180° Mask Rectangular Areas Over the Door Full Mask Specific Areas You Wish to Mask Page 7 Sensors LOS-CDT Series Occupancy Sensors 369653c 8 02.07.13 Sensor Adjustments Override Settings Auto/Manual Threshold LED Motion Indicator Reset Learned Settings A Off (Default) On 1 2 3 4 Manual on / off (Override) Automatic (Normal) Auto Threshold Adjustment High Sensitivity (Low turn-on threshold) Lights indicate motion Disable LED Indicator Retain Settings (Normal) Erase all learned settings; Restart Learning (Toggle On) OFF ON Strong Airflow Compensation Over Doorway Installation Timer Adjust Auto Sensitivity OFF (Default) B OffON 1 2 3 4 On Disable Compensation (Normal) Enable Compensation No (Normal) Yes (Use increased turn-on threshold) Adjust Timer Automatically Use Manual Setting (No adjustment) Adjust Sensitivity Automatically Adjust Sensitivity Manually OFF ON OFF ON Timer Test Mode Factory Settings 1. Remove the retainer cover. otate the black timer adjustment knob to about 2. R midway (12 o’clock). 3. Return setting to minimum setting (full CCW). Factory Settings 12 o’clock Full CCW NOTE: The timer will remain in the 8 second test mode for 1 hour, then automatically reset to 8 minutes. Red: Infrared sensitivity 75% default Black: Timer 8 min A B ON ON 1 2 3 4 1 2 3 4 Green: Ultrasonic range 50% default Blue: Photo cell (R models only) 100% default 4. T o manually take the timer out of the 8 second test mode, turn the timer adjustment approximately 1/16 in (1.5 mm) clockwise to make the setting slightly above minimum (just above the 8 minute setting). Continued on next page... S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 8 Sensors LOS-CDT Series Occupancy Sensors 369653c 9 02.07.13 Sensor Adjustments (continued) Adjusting the “Lights Not On” Level Control Settings (Blue Knob) LOS-CDT-500R-WH, LOS-CDT-1000R-WH, and LOS-CDT-2000R-WH only LOS-CDT-500R-WH, LOS-CDT-1000R-WH, and LOS-CDT-2000R-WH only 1. Place timer in Test Mode (see page 8). 2. Set photo cell to maximum. Turn the blue knob full clockwise (lights on no matter how bright the natural light is), then about 30° counterclockwise. 3. Check for Lights-Out. Move from underneath the sensor, and remain still until the lights turn off. Move around normally to turn the light on. 4. Adjust to desired level. If lights remain off, adjust the blue knob another 30° counterclockwise and repeat step 3 until the lights turn on. Minimum (low): Lights will never come on, even though room is occupied. 0 1000 Maximum (high): Photo cell has no effect on operation (factory setting). 0 1000 NOTE: Set blue knob to 100% to disable photo cell functionality and leave secondary dry contact closure output functionality intact. Normal: 200 lx to 600 lx is normal range. 0 S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: 1000 Page 9 PP and UPP Series -DV, -DV-M, -347H, -SH Power Packs 369544f 1 03.13.15 PP and UPP Series Power Packs PP and UPP* Series Power Packs provide both the 24 V- power supply to operate LutronR wired occupancy sensors, as well as the 16 A line-voltage relay to control the load, in one compact housing. The unit can be mounted inside a ballast enclosure or inside / outside a junction box. The manual-ON Power Pack (-DV-M) is used to provide a vacancy solution when paired with LutronR wired occupancy sensors. A low-voltage momentary switch should be used to manually turn ON the load while the sensor automatically shuts the load OFF when unoccupied. Pressing the momentary switch can also turn the load OFF. (-DV) (-DV-M) (-347H) The auxiliary Power Pack (-SH) must be used in conjunction with at least one line-voltage Power Pack and one Lutron wired occupancy sensor to switch additional loads. Features •High-impact UL94 flammability-rated plastic case construction •Relay: Class B 266 °F (130 °C) insulating material; silver alloy contacts •Complies with requirements for use in a compartment handling environmental air (plenum) per NEC® 2011 300.22(C)(3) •Power Pack units (PP-DV / UPP-DV, PP-347H, PP-DV-M / UPP-DV-M) power up to 3 total devices. PP-SH / UPP-SH counts as 1 device, each occupancy sensor counts as 1 device. •For indoor use only, 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing (-SH) Model Power Input Relay Contact Rating PP-DV UPP-DV PP-DV-M UPP-DV-M PP-347H 120-277 V~ 50/60 Hz 6.5 W •1 20-277 V~ 16 A; All lighting loads** • 120-277 V~ 1 HP Motor Load 347 V~ 60 Hz 6.5 W 24 V(At least one line-voltage Power Pack must be used) • 347 V~ 15 A Ballast 24 V- 5 mA •1 20-277 V~ 16 A; All lighting loads** • 120-277 V~ 1 HP Motor Load • 347 V~ 15 A Ballast 24 V- 5 mA PP-SH UPP-SH Control Input IEC PELV/ NEC® Class 2 Output 24 V- 5 mA 24 V- 150 mA up to 3 Devices *** 24 V- 100 mA up to 3 Devices *** N/A * “U” denotes BAA compliance ** Lighting loads include (but are not limited to): Incandescent, MLV, ELV, Resistive, Inductive *** PP-SH / UPP-SH counts as 1 device and each occupancy sensor counts as 1 device S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 1 PP and UPP Series -DV, -DV-M, -347H, -SH Power Packs 369544f 2 03.13.15 Specifications Regulatory Approvals Wiring •UL® and cUL® Listed •Complies with requirements for use in a compartment handling conditioned air (plenum) Power / Performance •PP-DV, UPP-DV, PP-DV-M, UPP-DV-M: 120-277 V~ 50/60 Hz •PP-347H: 347 V~ 60 Hz only •7 in (178 mm) wire leads, 18 AWG (0.75 mm2) input; 7 in (178 mm) leads, 16 AWG (1.5 mm2) contacts. Mounting •Fits inside standard 4 in x 4 in (102 mm x 102 mm) junction box or standard fluorescent fixture ballast cavity •Mount with 6/32 in (5 mm) x 11⁄4 in (32 mm) pan head screws •Mounts inside junction box through knockout, with 1/2 in (13 mm) Electrical Metallic Tubing (EMT) threaded nipple. Recommended volume is 30 in3 (762 mm3). Dimensions 2.33 in (59 mm) 1.36 in (35 mm) 3.69 in (94 mm) S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 2 PP and UPP Series -DV, -DV-M, -347H, -SH Power Packs 369544f 3 03.13.15 Wiring 3 Sensors with Power Pack (PP-DV, UPP-DV or PP-347H) 1 Line / Hot 120-277 V~ 50/60 Hz (PP-DV / UPP-DV) 347 V~ 60 Hz (PP-347H) Neutral White Black Red (24 V-) Blue (control) Power Pack (-DV or-347H) Black (common) Red Manual switch OFF 2 (optional – sold separately) Occupancy Sensors 1 Lighting Load Red Ground Maximum 3 occupancy sensors can be used with PP-DV / UPP-DV or PP-347H. When lights are manually turned off, switch must be returned back to the on position for occupancy sensors to function as set. 2 3 Sensors with Power Pack - Vacancy Solution (PP-DV-M, UPP-DV-M) 1 Line / Hot 120-277 V~ 50/60 Hz Neutral Lighting Load White Black Red Red Ground Power Pack (-DV-M) Red (24 V-) Blue (control) Black (common) Orange (manual override) Low-Voltage Momentary Switch 2 Occupancy Sensors 1 Maximum 3 devices (excluding low-voltage momentary switches) can be used with PP-DV-M / UPP-DV-M. Each PP-SH / UPP-SH counts as one device, each occupancy sensor counts as one device. 2 NTRCS-1 (Nova T*® momentary switch) or any low voltage momentary switch rated for at least 24 V-, 100 mA. continued on next page... S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 3 PP and UPP Series -DV, -DV-M, -347H, -SH Power Packs 369544f 4 03.13.15 Wiring (continued) Switching Multiple Loads with 1 Power Pack and 1 Auxiliary Power Pack 1 Line / Hot 120-277 V~ 50/60 Hz (PP-DV / UPP-DV); 347 V~ 60 Hz (PP-347H) Neutral Lighting Load Red Red Red (24 V-) Blue (control) Auxiliary Power Pack (-SH) Black (common) Power Pack (-DV or-347H) White Black Red Red Ground Lighting Load Ground Occupancy Sensors 1 Maximum of 3 devices can be used with PP-DV, UPP-DV, or PP-347H. Each PP-SH / UPP-SH counts as one device, each occupancy sensor counts as one device. Switching Multiple Loads with 2 Power Packs (PP-DV / UPP-DV) 120-277 V~ 50/60 Hz (PP-DV / UPP-DV); 347 V~ 60 Hz (PP-347H) Line / Hot 120-277 V~ 50/60 Hz (PP-DV / UPP-DV); 347 V~ 60 Hz (PP-347H) Neutral Neutral Red 1 White Black Red Red Lighting Load Power Pack (-DV or -347H) Red (24 V-) Blue (control) Black (common) White Power Pack (-DV or -347H) Ground Black Red Red Lighting Load Ground Occupancy Sensors 1 Only 1 Power Pack (PP-DV / UPP-DV) should power the occupancy senors. This 24 V- output is left disconnected. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 4 Diva® 0–10 V Control Wallbox Controls 369147b 1 09.08.14 Diva® 0–10 V Controls Controls for 0–10 V LED Drivers and Fluorescent Ballasts. Features • Large paddle switch with a captive linear-slide control for a standard designer-opening wallplate • 0–10 V control link controls third party fixtures • DVSTV- wires as single pole or 3-way, 120–277 V~ switch • DVTV- wires as a 24 V- switch. A Power Pack is required to switch 120–277 V~ and 347 V~ • Patented switching technology extends product lifetime • Coordinating Claro® and Satin Colors® wallplates (available separately) • High-end and low-end trim user adjustable for optimal performance Select light level with slider Switch on (to selected light level)/off Diva® 0–10 V Control A/E: Please confirm color, page 13. Model Numbers Model Number Operating Voltage 1 DVSTV-XX 120 –277 V~ 2 DVSCSTV-YY 1 DVTV-XX 24 V2 DVSCTV-YY 1 2 3 4 Load Switching Wiring Capacity 3 Single pole / 3-way 8 A Single pole only 0 A4 0–10 V Sink Capacity 50 mA 30 mA “XX” in the model number represents gloss finish color code. See Standard Colors and Finishes on Page 3. “YY” in the model number represents satin finish color code. See Standard Colors and Finishes on Page 3. For 3-way switching, use Claro ® switches or other mechanical switches. A Lutron® Power Pack (PP-DV or PP-347H) is required for switching ballasts and drivers. For Lutron ® Power Pack Specification please see Lutron ® P/N 369544. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage Job Number: Page 1 Diva® 0–10 V Control Wallbox Controls 369147b 2 09.08.14 Specifications DVSTV- Models Regulatory Approvals • UL® Listed to US and Canadian safety requirements UL244A Power Operating Voltage 120–277 V~ 50/60 Hz Output Ratings • Switch rating of 8 A • 0–10 V control link for 50 mA maximum output, sink ONLY 0–10 V Control Link • 0–10 V control link is Class 1 • Controls up to 25 ballasts or drivers (IEC 60929 Annex E.2 requires the ballast / driver to limit the current draw to 2.0 mA maximum) Environment • For Indoor Use Only. • Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity. Application Requirements • No derating required if ganged. • Night light not available. • Always consult local wiring codes. Warranty • 1 Year Limited Warranty. For additional Warranty information, please visit www.lutron.com/TechnicalDocumentLibrary/ 369-119_Wallbox_Warranty.pdf Performance • Power Pack cannot be used with DVSTV- models. • Works with all ballasts and drivers that provide a current source compliant to IEC 60629 Annex E.2, and whose inrush current does not exceed NEMA410 standards for electronic ballast/driver loads of 8 A steady state current. • Adjustable high-end and low-end trim for optimal dimming performance. • Power failure memory: should power be interrupted, the control will return to its previously set level prior to the interruption when power is restored. • Captive linear slider. • Precise color matching. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage Job Number: Page 2 Diva® 0–10 V Control Wallbox Controls 369147b 3 09.08.14 Specifications (continued) DVTV- Models Power Operating Voltage 24 V- 100 mA Output Ratings • Power Pack required for load switching. Power Pack is rated for 16 A • 30 mA maximum output, sink ONLY. 0–10 V Control Link • 0–10 V control is Class 2 • Controls up to 15 ballasts or drivers (IEC 60929 Annex E.2 requires the ballast / driver to limit the current draw to 2.0 mA maximum) Performance Environment • For Indoor Use Only. • Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity. Application Requirements • No derating required if ganged. • Night light not available. • Always consult local wiring codes. Warranty • 1 Year Limited Warranty. For additional Warranty information, please visit www.lutron.com/TechnicalDocumentLibrary/ 369-119_Wallbox_Warranty.pdf • For 120-277 V~ installations switching more than 8 A, use DVTV- with Lutron® Power Pack (model PP-DV; see Lutron® P/N 369544). • For 347 V~ installations, use DVTV- with Lutron® Power Pack (model PP-347H; see Lutron® P/N 369544). • Works with all ballasts and drivers that provide a current source compliant to IEC 60629 Annex E.2. • Adjustable high-end and low-end trim for optimal dimming performance. • Power failure memory: should power be interrupted, the 0–10 V- signal will return to its previously set level prior to the interruption when power is restored. • Captive linear slider. • Precise color matching. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage Job Number: Page 3 Diva® 0–10 V Control Wallbox Controls 369147b 4 09.08.14 Dimensions 2.75 in (70 mm) 4.69 in (119 mm) 2.94 in (75 mm) 0.30 in (7.6 mm) 1.31 in (33 mm) Standard Colors and Finishes Gloss Finishes Satin Colors® Add color suffix to model # Example: DVSTV-WH / DVTV-WH Add color suffix to model # Example: DVSCSTV-SW / DVSCTV-SW WH IV AL LA GR BR BL HT MR PL TQ SG TP ES BI SW PD White Ivory Almond Light Almond Gray Brown Black S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage Job Number: Hot Merlot Plum Turquoise Sea Glass Taupe Eggshell Biscuit Snow Palladium MN TC SI GB BG MS GS DS ST LS Midnight Terracotta Sienna Green Briar Bluestone Mocha Stone Goldstone Desert Stone Stone Limestone Page 4 Diva® 0–10 V Control Wallbox Controls 369147b 5 09.08.14 High-End and Low-End Adjustments DVSTV- Models All Models Front View Bottom View Maximum Light Level (High-End) Trim Minimum Light Level (Low-End) Trim DVTV- Models Side View Maximum Light Level (High-End) Trim S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage Job Number: Page 5 Diva® 0–10 V Control Wallbox Controls 369147b 6 09.08.14 Wiring Diagrams DVSTV- and DVSCSTVSingle Pole Wiring Line/Hot Switched Hot Red Black Red / White Violet (+) Gray (-) Violet (+) Gray (-) 0-10 V- Ballast/Driver Neutral 120–277 V~ 50/60 Hz Ground Switched Hot Violet (+) Gray (-) Neutral 0-10 V- Ballast/Driver Neutral 3-Way Wiring Line/Hot ** * Red Black Switched Hot * Red / White Violet (+) Gray (-) Violet (+) Gray (-) 3-Way Switch † 0-10 V- Ballast/Driver Neutral 120–277 V~ 50/60 Hz *** Ground Ground Switched Hot Violet (+) Gray (-) Neutral 0-10 V- Ballast/Driver Neutral * Copper / Black screw terminal ** Brass / Gold screw terminal *** Green screw terminal † Please refer to installation instructions for 3-Way switch for proper wiring. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage Job Number: Page 6 Diva® 0–10 V Control Wallbox Controls 369147b 7 09.08.14 Wiring Diagrams DVSTV- and DVSCSTV- (continued) 4-Way Wiring Line/Hot * ** 4-Way Switch † 3-Way Switch † * 120–277 V~ 50/60 Hz ** Red * ** Red / White * *** *** Ground Ground Black Switched Hot Violet (+) Gray (-) Violet (+) Gray (-) 0-10 V- Ballast/Driver Neutral Ground Switched Hot Violet (+) Gray (-) Neutral 0-10 V- Ballast/Driver Neutral Note: For 4-way wiring, control must be installed line side or load side. It cannot be installed in the 4-way location. * Copper / Black screw terminal ** Brass / Gold screw terminal *** Green screw terminal † Please refer to installation instructions for 3-Way /4-Way switch for proper wiring. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage Job Number: Page 7 Diva® 0–10 V Control Wallbox Controls 369147b 8 09.08.14 Wiring Diagrams DVTV- and DVSCTVDimming With ON/OFF Control Wiring Diagram Using a Power Pack Class 2 Only Neutral Violet (+) 0-10 V- Ballast/Driver Gray (-) Red / White Switched Hot Neutral Violet (+) Violet (+) Gray (-) Gray (-) 0-10 V- Ballast/Driver Switched Hot Red Blue Red Red PP-DV / PP-347H Black White Black Neutral 120–277 / 347 V~ 50 / 60 Hz Line / Hot Dimming With ON / OFF Control For Drivers Which Support Dim To OFF Capability Power Wiring Not Shown—See Lighting Device For Wiring Red/White Violet (+) Violet (+) Gray (-) Gray (-) 0-10 V- Ballast/Driver Red Blue Violet (+) 0-10 V- Ballast/Driver Gray (-) S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage Job Number: Page 8 Maestro® Occupancy/Vacancy Sensor with C•L Dimmer Sensor 369748b 1 03.13.13 MaestroR Occupancy Sensor C•LR Dimmer LutronR MaestroR occupancy sensor C•LR dimmers A/E: Does this meet design intent? are lighting controls with passive infrared sensors that automatically control the lights in an area. These sensors detect heat from occupants moving within an area to determine when the space is occupied. The MaestroR occupancy sensor C•LR dimmer combines a MaestroR C•LR dimmer with an occupancy or vacancy sensor. Features •C ontrols CFL, LED, incandescent, and halogen load types * •P assive infrared motion detection with exclusive LutronR XCTT Technology for fine motion detection • 180˚ sensor field-of-view •U p to 30 ft x 30 ft (9 m x 9 m) [900 ft2 (81 m²)] major motion coverage and 20 ft x 20 ft (6 m x 6 m) [400 ft2 (36 m²)] minor motion coverage • Occupancy version can be set to auto-on/auto-off or manual-on/auto-off • Vacancy version available to meet CA Title 24 requirements • Adjustable timeout (1, 3, 5, 15, or 30 minutes) and high/low sensitivity adjustment djustable settings for auto-on light level (occupied •A level): 100%, 50%, last light level, or locked preset light level • Off warning fades lights to off over a period of 10 seconds • Advanced MaestroR dimmer features available (locked preset, fade-to-on, and fade-to-off, etc.) • All models have single pole and multi-location capability • Works with a single standard mechanical 3-way switch or up to 9 companion dimmers/switches (MA-R or MSC-AD) ** Models Available Model Number *** Description Sensor Operation Maximum Capacity MSCL-OP153M-XX Occupancy/vacancy single-pole/ multi-location Auto-on/auto-off or manual-on/auto-off 600 W incandescent/halogen 150 W CFL/LED * MSCL-VP153M-XX Vacancy single-pole/multi-location Manual-on/auto-off 600 W incandescent/halogen 150 W CFL/LED * * For a complete list of compatible DIMMABLE CFLs and LEDs please visit www.lutron.com/dimcflled ** If using with standard mechanical 3-way switch, some rewiring and dimmer programming is required *** XX in model number represents color/finish code S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 1 Maestro® Occupancy/Vacancy Sensor with C•L Dimmer Sensor 369748b 2 03.13.13 Specifications Regulatory Approvals • UL Listed to U.S. and Canadian safety requirements • Title 20/24 certified lighting control device – Complies with Title 20 and Title 24 Section 119 (Until Jan 1st, 2014) • Title 20/24 certified lighting control device – Complies with Title 20 and Title 24 Section 110.9 (After Jan 1st, 2014) Power • Operating voltage: 120 V~ 60 Hz Environment • Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0%-90% humidity, non-condensing; indoor use only Warranty • 5 Year Limited Warranty For additional Warranty information, please visit: www.lutron.com/TechnicalDocumentLibrary/Sensor_ Warranty.pdf Key Design Features Dimmer •On a single-tap, lights fade ON or OFF •On a double-tap, lights go to full ON •When ON, press and hold to engage a long fade to OFF •Light levels can be fine-tuned by pressing and holding the dimming rocker until the desired light level is reached Custom Sensor Settings • • • • • • Timeout Options 1 Minute 3 Minute 5 Minutes (default) 15 Minutes 30 Minutes Test Mode – Short (less than 15-second) timeout for testing sensor coverage. After entering, device will exit test mode automatically after 5 minutes, or when any button is pressed. S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Sensitivity Options • High sensitivity (default) • Low sensitivity Auto-ON Options • Occupancy (default): Auto-ON / Auto-OFF – Occupancy Mode is also called “Auto-On: Enabled” • Vacancy *: Manual-ON / Auto-OFF – Vacancy Mode is also called “Auto-On: Disabled” *T here is a 15-second grace period that begins when the lights are automatically turned off, during which the lights will automatically turn back on in response to motion. This grace period is provided as a safety and convenience feature in the event that the lights turn off while the room is still occupied, so that the user does not need to manually turn the lights back on. After 15 seconds, the grace period expires and the lights must be manually turned on. • Ambient Light Detection (ALD): Lights turn on only if natural light in room is low – Smart—Ambient light threshold adjusts to the user’s preference ** ** If sensor turns on when there is enough natural light, or if sensor does not turn on when there is not enough natural light, press the large button within 5 seconds of entering the room. Over time, this interaction will “teach” the sensor your preferred setting. • Off While Occupied (OWO) – When the sensor dimmer is manually turned off, the sensor dimmer will not turn the lights back on automatically while the room is occupied. – Once the room is vacated, the Auto-ON feature returns to normal operation after the timeout period has expired. – This may be the preference in conference rooms or classrooms while viewing presentations. This feature requires motion to keep the lights off. Occupied Level Options Occupied Level is the light level that the sensor dimmer will turn ON to when motion is detected. • 100% (default) •50% •Preset – While in preset mode, lights will automatically turn to the last level or to the “Locked Preset” level if a “Locked Preset” has been selected in Advanced Programming. Page 2 Maestro® Occupancy/Vacancy Sensor with C•L Dimmer Sensor 369748b 3 03.13.13 Load Type and Capacity Control Voltage MSCL-OP153M MSCL-VP153M 1 2 3 120 V~ Load Type 1 Incandescent, halogen, CFL, LED 2 Minimum Load 1 bulb, or as noted on approved bulb list 3 Maximum Load Neutral Connection Required Not Ganged End of Gang Middle of Gang 600 W incan/ halogen or 150 W CFL/ LED 400 W incan/ halogen or NO 150 W CFL/ LED 500 W incan/ halogen or 150 W CFL/ LED Dimmer Load Type: designed for use with permanently installed lighting fixtures only. Do not install dimmers to control receptacles or motor-operated appliances. For mixed load types, see Mixed Load Type and Capacity section. For a complete list of approved Dimmable CFLs and LEDs, please visit www.lutron.com/dimcflled. For questions call: 1.800.523.9466. Mixed Load Type and Capacity Determine allowable wattage (W) of dimmer by following the steps below. If multiple dimmers are to be installed adjacently in the same wallbox, derating is required. 1. 2. 3. 4. Derating Chart Determine total wattage of CFL/LED bulbs installed for dimmer control. D etermine total wattage of Incandescent/ Halogen bulbs to be controlled by the dimmer. U se the Derating Chart to determine if your total wattages are within the allowable range of your configuration. Derating Procedure (if necessary) If multiple dimmers are installed adjacently in the same wallbox, heat fins MUST be removed between adjacent dimmers. This will permanently derate the dimmer, reducing its total allowable Incandescent/Halogen wattage. Derating Chart Placing dimmers adjacent to mechanical switches does not require derating. A CFL CFL LFCA LFCA AFC AFC LED LED DEL DEL B B C B Incandescent / Halogen : Total Wattage INC / HAL Total W CFL/LED 0W 1 W – 25 W 26 W – 50 W 51 W – 75 W 76 W – 100 W 101 W – 125 W 126 W – 150 W B + A 10 W – 600 W 0 W – 500 W 0 W – 400 W 0 W – 300 W 0 W – 200 W 0 W – 100 W 0W B B 10 W – 500 W 0 W – 400 W 0 W – 300 W 0 W – 200 W 0 W – 100 W 0 W – 50 W 0W C C 10 W – 400 W 0 W – 300 W 0 W – 200 W 0 W – 100 W 0 W – 50 W 0W 0W Heat Fins Example If heat fins from one side of dimmer are removed (see B in chart) and you have two 24 W CFL bulbs installed (Total CFL Wattage = 48 W), you may add up to 300 W of Incandescent/Halogen lighting. Additional Information • For MaestroR Occupancy sensing switch models, please see LutronR P/N 369666 at www.lutron.com. •Lutron Technical Hotline: 1.800.523.9466. S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 3 Maestro® Occupancy/Vacancy Sensor with C•L Dimmer Sensor 369748b 4 03.13.13 MaestroR Occupancy Sensor C•LR Dimmer Placement and Operation • The ability of the sensor dimmer to detect motion requires line-of-sight of room occupants. The sensor dimmer must have an unobstructed view of the room. Hot objects and moving air currents can affect the performance of the sensor dimmer. For best performance, the • sensor dimmer should be mounted at least 4 ft (1.2 m) away from HVAC vents and light bulbs. • The performance of the sensor dimmer depends on a temperature differential between the ambient room temperature and that of room occupants. Warmer rooms may reduce the ability of the sensor dimmer to detect occupants. NEMA WD7 Test Grid Coverage (High Sensitivity Setting) Horizontal Beam Diagram 30 ft (9 m) Major motion coverage: 900 ft( (81 m() 25 ft (7.5 m) Minor motion coverage: 400 ft( (36 m() 20 ft (6 m) 15 ft (4.5 m) 15 ft (4.5 m) 10 ft (3 m) 10 ft (3 m) 5 ft (1.5 m) 0 5 ft (1.5 m) 5 ft (1.5 m) 10 ft (3 m) 15 ft (4.5 m) 0 20 ft (6 m) 25 ft (7.5 m) 5 ft (1.5 m) 30 ft (9 m) 10 ft (3 m) Vertical Beam Diagram 4 ft (1.2 m) 15 ft (4.5 m) 0 5 ft (1.5 m) 10 ft (3 m) 15 ft (4.5 m) 20 ft (6 m) S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: 25 ft (7.5 m) 30 ft (9 m) 0 5 ft 10 ft 15 ft 20 ft 25 ft 30 ft 35 ft (1.5 m) (3 m) (4.5 m) (6 m) (7.5 m) (9 m) (10.7 m) Page 4 Maestro® Occupancy/Vacancy Sensor with C•L Dimmer Sensor 369748b 5 03.13.13 Operation NOTE: Status LEDs Indicate light level; glow softly as night light when light is off * LED only pulses to acknowledge motion when there is motion AND the load is ON. Dimming Rocker Press to brighten Press to dim Tapswitch Tap on / off; Double-tap - lights go to full on Sensor Lens Sensor LED * FASST Front Accessible Service Switch Important notice: FASST – Front Accessible Service Switch – to service load, remove power by pulling the FASST switch out completely on either the sensor dimmer or companion dimmer. After servicing load, push the FASST switch back in fully to restore power to the control. Once power has been restored, the sensing dimmer can be manually turned on or off but will not automatically control the load for the first 2 minutes. Mounting Mounting Screws Adapter Mounting Screws Wallplate Wallbox MaestroR Occupancy Sensor C•LR Dimmer Wallplate / Adapter purchased separately. Wallplate Adapter S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 5 Maestro® Occupancy/Vacancy Sensor with C•L Dimmer Sensor 369748b 6 03.13.13 Dimensions Measurements shown as: in (mm) Side View Front View 411⁄16 (119) 215⁄16 (75) 11⁄8 (30) 1/8 (3) 5/16 (8) Note: MSCL-OP153M and MSCL-VP153M have screw terminals. S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 6 Maestro® Occupancy/Vacancy Sensor with C•L Dimmer Sensor 369748b 7 03.13.13 Wiring Diagrams Wiring Diagram 1 Single Location Installation 1 MSCL-OP153M and MSCL-VP153M Sensor Dimmer Blue 1 Brass Line/Hot Black Green Wire 120 V~ 60 Hz Load Ground Neutral Wiring Diagram 2 Multi-Location Installation 2, 3, 4 MSCL-OP153M and MSCL-VP153M with MA-R or MSC-AD Sensor Dimmer Brass Blue Companion Dimmer Brass Blue Companion Dimmer Brass Blue Line/Hot Black Black Green Wire 120 V~ 60 Hz Black Green Wire Ground Green Wire Ground Load Ground Neutral When using controls in single location installations, tighten the blue terminal. Do not connect the blue terminal to any other wiring or to ground. Up to 9 companion dimmers may be connected to a sensor dimmer. Total blue terminal wire length may be up to 150 ft (46 m). 3 Only one sensor dimmer can be used per multi-location circuit. 4 Sensor dimmer can be installed in any location in the circuit. 1 2 S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 7 Maestro® Occupancy/Vacancy Sensor with C•L Dimmer Sensor 369748b 8 03.13.13 Wiring Diagrams (continued) Wiring Diagram 3 3-way Installation with Standard Mechanical Switch (120 V~) 1, 2 MSCL-OP153M and MSCL-VP153M Standard mechanical switch 3 Sensor Dimmer Brass Line/Hot Jumper wire Blue Different color screw (Common) Green screw 120 V~ 60 Hz Black Green Wire Ground Load Ground Neutral OR Sensor Dimmer Brass Line/Hot Standard mechanical switch 3 Black Blue Green screw Green Wire 120 V~ 60 Hz Ground Different color screw (Common) Ground Jumper wire Load Neutral 1 2 3 Only one sensor dimmer can be used per multi-location circuit. single standard mechanical 3-way switch or up to 9 companion dimmers may be connected to a sensor dimmer. Standard mechanical 3-way switch A cannot be combined with companion dimmer. Total blue terminal wire length may be up to 150 ft (46 m). Diagram 3 shows a typical retrofit scenario, where one mechanical 3-way switch is being replaced with a sensor dimmer. The remaining mechanical 3-way switch needs to be modified to effectively convert it to a single pole switch. For new construction, a standard mechanical single pole switch can be used here. S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 8 Maestro® Occupancy/Vacancy Sensor with C•L Dimmer Sensor 369748b 9 03.13.13 Colors and Finishes A/E: Please confirm color. Gloss Finishes Satin Finishes White WH Ivory IV Hot HT Merlot MR Plum PL Turquoise TQ Almond AL Light Almond LA Taupe TP Eggshell ES Biscuit BI Snow SW Gray GR Brown BR Palladium PD Midnight MN Sienna SI Terracotta TC Greenbriar GB Bluestone BG Mocha Stone MS Goldstone GS Desert Stone DS Stone ST Limestone LS Sea Glass SG Black BL Due to printing limitations, colors and finishes shown cannot be guaranteed to perfectly match actual product colors. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 9 Radio Powr SavrTM LRFX-DCRB Wireless Daylight Sensor 369262i 1 03.24.16 Radio Powr SavrT Wireless Daylight Sensor A/E: Please confirm color. The LutronR wireless daylight sensor is a battery-powered sensor that automatically controls lights via RF communication to compatible dimming or switching devices. This sensor mounts to the ceiling and measures light in the space. The sensor then transmits the light level to the associated dimming or switching devices that automatically control the lights to balance light level in the space. The sensor combines both convenience and exceptional energy savings potential along with ease of installation. Features •Wireless daylight sensor has simple calibration. •Daylight compensation through LutronR reliable open loop control. •Designed to give a linear response to changes in viewed light level. •Light range 0 to 1600 lx (0 to 150 fc). •Uses Clear ConnectR technology. •Works with Radio Powr SavrTM occupancy / vacancy sensors and Pico® wireless controls. •Intuitive test mode provides instant system verification. •Multiple ceiling-mount methods available for different ceiling materials. •Front accessible test buttons make setup easy. •10-year battery life. •RoHS compliant. Model Number LRFX-DCRB-WH Color Code Frequency / Channel Code Frequency / Channel Codes 2 = 431.0 – 437.0 MHz (U.S.A., Canada, Mexico, Brazil) 3 = 868.125 – 869.850 MHz (Europe, U.A.E.) 4 = 868.125 – 868.475 MHz (China, Singapore) 5 = 865.5 – 866.5 MHz (India) 6 = 312.3 – 314.8 MHz (Japan) 7 = 433.05 – 434.79 MHz (Hong Kong, Macau) Color Code WH = White Compatible RF Devices •For use with Lutron® products only. •Communicates to various wireless Lutron® systems*. *Contact LutronR Customer Service at www.lutron.com for frequency/channel code compatibility with your particular geographic region, and for integrating with other LutronR lighting and shading products. S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 1 Radio Powr SavrTM LRFX-DCRB Wireless Daylight Sensor 369262i 2 03.24.16 Specifications Regulatory Lutron® Quality Systems Registered to ISO 9001:2008 Standards LRF2•FCC certified •IC certified •COFETEL •ANATEL •ASEP •CRC •SUBTEL •SUPERTEL •SUTEL •Meets CA (U.S.A.) Energy Commission Title 24 requirements •cULus Listed LRF3•CE Marked (European Union) •TRA Type Approved (United Arab Emirates) •CITC (Kingdom of Saudi Arabia) LRF4•SRRC Type Approved (Mainland China) •iDA Registered (Singapore) LRF5•WPC Type Approved (India) Power / Performance •Operating voltage: 3 V•Operating current: 7 µA •Requires one CR 2450 lithium battery •10-year battery life •Non-volatile memory (settings are stored during power loss) Enviroment •Temperature: 32 ºF to 104 ºF (0 ºC to 40 ºC) •For indoor use only •Relative humidity: < 90% non-condensing Range •LRF2-, LRF3-, LRF4-, LRF5-, LRF7Local load controls must be located within 60 ft (18 m) line of sight, or 30 ft (9 m) through walls, of a sensor. •LRF6Local load controls must be located within 23 ft (7 m) through walls of a sensor. Dimensions 0.7 in (17 mm) LRF6• 007YUUL0688 LRF7•FCC certified 1.6 in (41 mm) S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 2 Radio Powr SavrTM LRFX-DCRB Wireless Daylight Sensor 369262i 3 03.24.16 Mounting Installation Overview Location for average size areas Determine the Daylight Sensor mounting location using the diagrams at left: Arrow points towards the area viewed by the sensor (towards windows). Bottom of sensor 1-2 H H 3 ft (1 m) H = Effective Window Height Location for narrow areas (corridors, private offices) Arrow points towards the area viewed by the sensor (away from window) Bottom of sensor S P E C I F I C AT I O N S U B M I T TA L Job Name: Model Numbers: Gateway Mortgage ® Job Number: •The arrow on the daylight sensor points toward the area viewed by the sensor. •Place the daylight sensor so the arrow is pointed at the nearest window at a distance from the window of one to two times the effective window height (H). •The effective window height (H) starts at the window sill or 3 ft (1 m) up from the floor, whichever is higher, and ends at the top of the window. •Ensure that the view of the daylight sensor is not obstructed (e.g. ceiling fans or pendant fixtures). •Do not position the daylight sensor above an electric light that shines up at the ceiling or at the sensor. •Do not position the daylight sensor in the well of a skylight or above indirect lighting fixtures. •For narrow areas where the daylight sensor cannot be placed 1-2 (H) from windows, place sensor near windows facing into the space. • Mount sensor(s) away from large metal surfaces (e.g. light fixtures or metal-backed ceiling tiles). Metal objects will affect the RF performance of the sensor. • For detailed and application specific mounting information, please see "Daylight Sensor Design and Application Guide" (P/N 3683587) at www.lutron.com/TechnicalDocumentLibrary/3683587_ Daylight_Sensor_Design_and_App_Guide_sg.pdf Page 3 Radio Powr SavrTM Ceiling Wireless Occupancy/Vacancy Sensor 369480h 1 02.16.16 Radio Powr SavrTM Wireless Occupancy / Vacancy Ceiling Sensor A/E: Please confirm color. Lutron® Radio Powr SavrTM occupancy/vacancy sensors are wireless, battery-powered, passive infrared (PIR) sensors that automatically control lights via RF communication to compatible dimming and switching devices. These sensors detect the heat (IR radiation of 9.5 μm) from people moving within an area to determine when the space is occupied. The sensors then wirelessly transmit the appropriate commands to the associated dimming and switching devices to turn the lights on or off automatically. They combine both convenience and exceptional energy savings potential along with ease of installation. Features • Wireless occupancy sensor has 3 settings available: Auto‑On/Auto-Off, Auto-On Low-Light/Auto-Off, and Manual-On/Auto-Off • Auto-On Low-Light feature will turn lights on automatically only if there is less than approximately 10 Lux (1 fc) of ambient light • Vacancy-only model available to meet California (U.S.A.) Title 24 requirements • Uses Clear Connect® technology • Passive infrared motion detection with exclusive Lutron® XCTTM Technology for fine motion detection • 360˚ coverage ranges from 324 ft2 (30.2 m2) to 676 ft2 (62.4 m2), depending on mounting height • Simple and intuitive adjustments available for Timeout, Auto-On, and Activity settings • Supports advanced occupancy features, such as dependent occupancy groups and customizable occupied/unoccupied presets in some systems • Multiple sensors can be added for extended coverage. Refer to product specification submittal of receiving device to determine system limits • Lens illuminates during test mode to verify ideal locations • Multiple ceiling-mount methods available for different ceiling materials • Front accessible test buttons make programming easy • 10-year battery life design • RoHS compliant S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Models Available • LRF -OCR2B-P-WH • LRF2-VCR2B-P-WH Color Code Occupancy and Vacancy Frequency/Channel Code Vacancy Only Available for Channel Code 2 Only Frequency/Channel Codes Available 2 = 431.0 – 437.0 MHz (U.S.A., Canada, Mexico, Brazil) 3 = 868.125 – 869.850 MHz (Europe, U.A.E.) 4 = 868.125 – 868.4755 MHz (China, Singapore) 5 = 865.5 – 866.5 MHz (India) 6 = 312.3 – 314.8 MHz (Japan) 7 = 433.05 – 434.79 MHz (Hong Kong, Macau) Color Code WH = White Compatible RF Devices • For use with Lutron® products only • Communicates to various wireless Lutron® systems* * Contact Lutron® Customer Service at www.lutron.com for frequency/ channel code compatibility with your particular geographic region, and for integrating with other Lutron® lighting and shading products. Page 1 Radio Powr SavrTM Ceiling Wireless Occupancy/Vacancy Sensor 369480h 2 02.16.16 Specifications Range Regulatory • Lutron® Quality Systems Registered to ISO 9001:2008 LRF2-, LRF3-, LRF4-, LRF5-, LRF7Local load controls must be located within 60 ft (18 m) line-of-sight, or 30 ft (9 m) through walls, of a sensor. Standards Approved LRF2- (USA and Canada) cULus Listed FCC certified IC certified Meets CA (U.S.A.) Energy Commission Title 24 requirements • COFETEL • ANATEL • SUTEL LRF6Local load controls must be located within 40 ft (12.2 m) line-of-sight, or 23 ft (7 m) through walls, of a sensor. • • • • LRF3• CE marked (European Union) • TRA type approval (United Arab Emirates) • CITC type approval (Saudi Arabia) LRF4• SRRC type approval (Mainland China) • iDA registered (Singapore) LRF5• WPC Type (India) LRF6007YUUL0689 • LRF7• FCC Power/Performance • • • • • Operating voltage: 3 VOperating current: 14 μA nominal Requires one CR 123 lithium battery 10-year battery life Non-volatile memory (saved changes are stored during power loss) Environment • Temperature: 32 ˚F to 104 ˚F (0 ˚C to 40 ˚C) • For indoor use only Warranty • 5 -Year Limited Warranty. For additional Warranty information, please visit www.lutron.com/ TechnicalDocumentLibrary/Sensor_Warranty.pdf S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Sensor Coverage Test • Front accessible test button • Lens illuminates orange in response to motion during test mode and is visible from 60 ft (18 m) Wireless Communication Test • Front accessible test button • Turn associated loads on and off Timeout Options • • • • 1 minute* 5 minutes 15 minutes (default setting) 30 minutes Auto-On Options (Occupancy Versions Only) • Enabled: Sensor turns lights ON and OFF automatically (default setting). • Low Light: Sensor turns lights ON automatically only in low ambient light conditions; sensor turns lights OFF automatically. • Disabled**: Lights must be turned ON manually from dimming or switching device; sensor turns lights OFF automatically. Activity Options • Low Activity: (default setting) • Medium Activity: • High Activity: * Intended for use in high-activity, briefly occupied areas only. ** During the 15-second grace period that begins when the lights are automatically turned off, the lights will automatically turn back on in response to motion. This grace period is provided as a safety and convenience feature in the event the lights turn off while the room is still occupied, so that the user does not need to manually turn the lights back on. After 15 seconds, the grace period expires and the lights must be manually turned on. Page 2 Radio Powr SavrTM Ceiling Wireless Occupancy/Vacancy Sensor 369480h 3 02.16.16 Installation Overview Mounting Sensor Setup Temporary mounting is optional to test sensor coverage and wireless communication before permanently installing the sensor. • Sensor setup is available as a service by Lutron. For more information see the Sensor Layout and Tuning service document (Lutron® P/N 3601235). Sensor Placement • To detect motion, the sensor requires line-of-sight of room occupants. The sensor must have an unobstructed view of the room. DO NOT mount behind or near tall cabinets, shelves, hanging fixtures, ceiling fans, etc. The sensor cannot see through glass objects such as patio- or shower doors. • Hot objects and moving air currents can affect the performance of the sensor. To ensure proper operation, the sensor should be mounted at least 4 ft (1.2 m) away from HVAC vents and light bulbs that are below the ceiling line. • The performance of the sensor depends on a temperature differential between the ambient room temperature and that of room occupants. Warmer rooms may reduce the ability of the sensor to detect occupants. • Devices emitting Radio Frequency (RF) energy can affect the performance of sensors. To ensure proper operation, sensors should be mounted at least 4 ft (1.2 m) away from devices that emit radio waves (e.g., microwave ovens, wireless routers or other wireless devices). • For additional information on placing sensors, please see the Occupancy/Vacancy Sensor Design and Application Guide (P/N 368-3197) located at www.lutron.com. S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Drop Ceiling (Compressed Fiber Ceiling Tile) The mounting wire is provided for both temporary and permanent mounting of the sensor to ceiling tiles. It is designed to allow temporary mounting, testing, and repositioning (if necessary) of the sensor without damaging a ceiling tile. Once the final position of the sensor has been chosen, the mounting wire should be twisted together to permanently secure the sensor in place. Solid Ceiling (Drywall, Plaster, Concrete, or Wood) • Temporary mounting: Ten (10) temporary mounting strips can be purchased in the kit, L-CMDPIRKIT, for temporarily mounting and testing the sensor. • Permanent mounting: Screws and anchors (for drywall or plaster) provided to mount the sensor. Recess-Mount • Do not recess-mount sensor in a metal surface. • Recess-mounting ring requires an opening of 3 in (76 mm) in diameter. • Recess-mounting ring secures internally to ceiling. Sensor twists into the recess mounting ring and sits flush with ceiling (see image below). • Recess-mounting ring purchased as a separate kit: L-CRMK-WH. Page 3 Radio Powr SavrTM Ceiling Wireless Occupancy/Vacancy Sensor 369480h 4 02.16.16 Dimensions 3.57 in (90.7 mm) 2.85 in (72.4 mm) 0.88 in (22.5 mm) 1.13 in (28.7 mm) S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 4 Radio Powr SavrTM Ceiling Wireless Occupancy/Vacancy Sensor 369480h 5 02.16.16 Range Diagrams Ceiling 8 ft (2.4 m) Floor 15 ft 12 ft 9 ft 6 ft 3 ft (4.6 m) (3.7 m) (2.7 m) (1.8 m) (0.9 m) 0 3 ft 6 ft 9 ft 12 ft 15 ft (0.9 m) (1.8 m) (2.7 m) (3.7 m) (4.6 m) 18 ft × 18 ft (5.5 m × 5.5 m) maximum square coverage area whenmounted on an 8 ft (2.4 m) ceiling Sensor 13 ft (4.0 m) radius of coverage at floor when mounted on an 8 ft (2.4 m) ceiling Occupant Sensor Coverage Chart (for sensor mounted in center of room) Ceiling Height 8 ft (2.4 m) 9 ft (2.7 m) 10 ft (3.0 m) 12 ft (3.7 m) Maximum Square Coverage Area* 18 ft × 18 ft (5.5 m × 5.5 m) 324 ft2 (30.2 m2) 20 ft × 20 ft (6.1 m × 6.1 m) 400 ft2 (37.2 m2) 22 ft × 22 ft (6.7 m × 6.7 m) 484 ft2 (44.9 m2) 26 ft × 26 ft (7.9 m × 7.9 m) 676 ft2 (62.4 m2) * 12 ft (3.7 m) is the recommended maximum mounting height S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 5 Radio Powr SavrTM Ceiling Wireless Occupancy/Vacancy Sensor 369480h 6 02.16.16 Lens Masking Whenever possible, the sensor should be installed in a location where it cannot view areas outside the intended space, such as hallways or adjacent rooms. If this situation cannot be avoided, portions of the lens may be masked to block the view of the sensor into undesired areas. Ten (10) PIR Lens Masks may be purchased in the kit, L-CMDPIRKIT. Lens sections shown in gray are not masked Lens sections shown in white are masked with labels PIR Lens Mask sold separately (L-CMDPIRKIT) Hallway falls within Sensor’s coverage area. S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 6 PowPak™ Relay Module with SoftSwitch® Energi TriPak™ Series Wireless Lighting Control 369-428d 1 10.11.11 PowPak™ Relay Module with SoftSwitch® The PowPak™ Relay Module with SoftSwitch® is a radio frequency (RF) device that uses Lutron patented SoftSwitch® technology to control up to 16 A of general-purpose load based on input from Pico® controls and Radio Powr Savr™ occupancy and daylight sensors. An optional, low-voltage dry contact closure output is available to communicate occupancy status to 3rd-party systems such as HVAC controllers. Communication with RF input devices, such as Pico® controls and Radio Powr Savr™ sensors, is accomplished using Lutron Clear Connect™ RF Technology. Features •SoftSwitch®: Lutron patented technology prevents arcing of relay contacts, extending product lifetime •Various operating voltages available—refer to model number chart below for details on voltage requirements •Capable of switching 16 A of general-purpose loads •Optional low-voltage dry contact closure output provides integration to building management systems, HVAC, VAV, etc. •Receives wireless inputs from up to nine Pico® controls, six Radio Powr Savr™ occupancy/vacancy sensors, and one Radio Powr Savr™ daylight sensor •Utilizes Lutron Clear Connect™ RF Technology – refer to model number chart below for frequency band data •Mounts to a junction box through a standard half-inch (NPT trade size) knockout •Complies with requirements for use in a compartment handling environmental air (plenum) per NEC® 2011 300.22(C)(3) Description Model Number PowPak™ Relay Module with SoftSwitch® PowPak™ Relay Module with SoftSwitch® and Occupancy-Status CCO Frequency Band Region RMJ-16R-DV-B Operating Voltage 120 / 277 V~ 431.0 – 437.0 MHz RMQ-16R-DV-B RMJ-16RCCO1-DV-B 220-240 V~ 120 / 277 V~ 433.05 – 434.79 MHz 431.0 – 437.0 MHz RMQ-16RCCO1-DV-B 220-240 V~ 433.05 – 434.79 MHz U.S.A., Canada, Mexico Hong Kong U.S.A., Canada, Mexico Hong Kong Note: Contact Lutron for frequency band compatibility for your geographic region if it is not indicated above. S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 1 PowPak™ Relay Module with SoftSwitch® Energi TriPak™ Series Wireless Lighting Control 369-428d 2 10.11.11 Specifications Regulatory Approvals RMJ- models only •UL Listed •UL 2043 Plenum Rated •FCC approved. Complies with the limits for a Class B device, pursuant to Part 15 of the FCC rules. •CSA and IC •COFETEL •NOM (expected Q1 2012) Power •Operating voltage: RMJ- models 120/277 V~ 50 / 60 Hz RMQ- models 220-240 V~ 50 / 60 Hz System Communication •Operates using Clear Connect™ RF Technology for reliable wireless communication; refer to model number chart on page 1 for band frequency details •RF range is 30 ft (10 m) Environment •Ambient operating temperature: 32 °F to 131 °F (0 °C to 55 °C) •0% to 90% humidity, non-condensing •For indoor use only SoftSwitch® •Patented SoftSwitch® circuit eliminates relay arcing at mechanical contacts •Extends relay life to an average of 1 million cycles •Output is non-latching Load •Maximum load: 16 A general purpose. No minimum load requirements. •Load types include (but are not limited to): Incandescent, MLV, ELV, Resistive, Inductive, Magnetic fluorescent, Electronic fluorescent •Motor rating: RMJ- models 0.5 HP (120 V~), 1.5 HP (277 V~) RMQ- models 1.5 HP (220-240 V~) S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Key Design Features •LED status indicator shows current load status and provides programming feedback •Power failure memory: If power is interrupted, connected loads will return to the previous level prior to interruption •Daylighting can be overridden by pressing the ON button on any associated Pico® – Daylighting will be re-enabled after 2 hours or after the area becomes unoccupied Contact Closure Output (CCO version only) •Provides occupancy status to 3rd-party equipment such as building management systems, HVAC, and VAV controllers •Provides both normally open (NO) and normally closed (NC) dry contacts •Maintained output type •CCO terminals accept 20 to 16 AWG (0.5 to 1.5 mm2) solid or stranded wire •Output is latching •Not for voltages greater than 24 V Switching Voltage 0-24 V0-24 V~ Resistive Load 1.0 A 0.5 A R •The CCO is not rated to control unclamped, inductive loads. Inductive loads include, but are not Switching Resistive Flyback limited to, relays, solenoids, and motors. To control Voltage Load Diode Inductivea flyback diode must be these types of equipment, (required for 0-24 V1.0 A Load inductive used (DC voltages only). See diagram below. For 0-24 V~ 0.5 A moreloads) information, please see+ Application Note # 434 NO (p/n 048434). NC R CCO Output Flyback Diode (required for inductive loads) NO CCO Output COM 24 Vmax. Inductive Load NC COM + 24 Vmax. Page 2 PowPak™ Relay Module with SoftSwitch® Energi TriPak™ Series Wireless Lighting Control 369-428d 3 10.11.11 System Diagram To power source and load Pico® Control (up to 9) Test Radio Powr Savr™ Occupancy Sensor (up to 6) To 3rd-Party Equipment Radio Powr Savr™ Daylight Sensor (up to 1) Wiring Diagram Junction Box HOT White NEUTRAL SWITCHED HOT Black LOAD Red Occupancy-Status CCO (RM__-16RCCO1-DV-B only) NC NO COM To 3rd-Party Equipment S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 3 PowPak™ Relay Module with SoftSwitch® Energi TriPak™ Series Wireless Lighting Control 369-428d 4 10.11.11 Wiring Diagram Input Voltage White (Neutral) To Load Red Black (Switched Hot) (Hot) Conduit Nut COM To 3rd Party Equipment (Common) NO NC (Normally Open) (Normally Closed) Note: When wiring CCO to 3rd-party systems, use 20 to 16 AWG (0.5 to 1.5 mm2) solid or stranded wire. CCO operation affected only by associated occupancy or vacancy sensors. Room Occupied: NO = Close NC = Open Room Unoccupied: NO = Open NC = Close BOX A In some applications, a PowPak™ module can be installed inside a 4 in x 4 in (102 mm x 102 mm) junction box. For information about how to perform this installation, please see Application Note #423 (p/n 048423). BOX B Antenna PowPak™ Installation Inside Junction Box (Dimming Module RMJ-ECO32-DV-B shown) S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 4 PowPak™ Relay Module with SoftSwitch® Energi TriPak™ Series Wireless Lighting Control 369-428d 5 10.11.11 Dimensions Dimensions are shown as: in (mm) Half-inch NPT Trade Size 3.94 (100.1) 3.42 (86.9) 2.82 (71.6) 1.25 (31.8) Range Diagram PowPak™ Relay Module Radio Powr Savr™ Occupancy Sensor 30 ft (10 m) Maximum Pico® Wireless Transmitter 30 ft (10 m) Install in center of room to maximize RF coverage. 40 ft (12 m) All Wireless Transmitters must be installed within 30 ft (10 m) of the PowPakTM Relay Module. •Contact Lutron first for applications using foil-backed or metallic ceiling tiles. S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 5 PowPak™ Relay Module with SoftSwitch® Energi TriPak™ Series Wireless Lighting Control 369-428d 6 10.11.11 Default Operation Transmitting Device Pico® Radio Powr Savr™ Occupancy Sensor Radio Powr Savr™ Vacancy Sensor Radio Powr Savr™ Daylight Sensor Transmitted Command On Off Raise Lower Preset Occupied Unoccupied Occupied Unoccupied Ambient Light Below Target Level Ambient Light Above Target Level SoftSwitch® Relay Default Action Close Open No Action No Action Close Close Open No Action Open Close CCO Default Action No Action No Action No Action No Action No Action NO = Close, NC = Open NO = Open, NC = Close NO = Close, NC = Open NO = Open, NC = Close No Action Open No Action S p e c i f i c at i o n S u b m i t ta l Job Name: Model Numbers: Gateway Mortgage ® Job Number: Page 6