Technical Manual - REBELLE Architectural Lighting

Sightlines
R10.1
TECHNICAL MANUAL
Recessed Ceiling
Recessed Downlight/Vandal Resistant
CONCEPT
VANDAL RESISTANT RECESSED DowNLIGHT
The Sightlines 8000 Recessed Downlight Series is a premium quality,
vandal resistant recessed downlight designed for exterior canopies
and soffits. The luminaire design matches indoor open reflector
downlights in appearance to provide visual uniformity between
the building exterior and interior. Available in two constructions - a
specific concrete pour design and a standard non insulated ceiling
version for inverted T-bar, drywall, wet ceiling and metal ceiling
constructions. All units are “wet location” labeled with an ingress
protection level equivalent to IP 55. The Sightlines 8000 Series
provide the maximum vandal resistance to protect recessed lighting
installations in exposed public areas.
S I GH T L I NES
RECESSED CEILING
-2-
The SighTlineS Family
R ecessed c eiling
The Sightlines 8000 Recessed Downlight Series comes
in two constructions - a specific concrete pour design
and a standard non insulated ceiling version for inverted
T-bar, drywall, wet ceiling and metal ceiling constructions.
The optical system is designed to accommodate horizontal compact fluorescent and metal halide, medium base
lamps. The specular reflector is formed from high purity
aluminum sheet that is polished, buffed and anodized to
provide a low iridescent finish.
Hollow Ceiling
CF
8000
8000CG
Hollow Ceiling
Concrete Pour
Concrete Pour
HID
8000
8000CG
Concrete Pour
Hollow Ceiling
SI G HT L I N E S
RECESSED CEILING
-3-
DimenSionS
T-Bar / PlaSTer / Drywall / meTal SoFFiT ConSTruCTion
7.4"
2"
CLEARANCE
RECESSED
DEPTH
7.1"
LIGHT OPENING
9.0"
CEILING CUT OUT
9.8"
OVERALL TRIM
2.09"
11"
5.25"
2.88"
2.09"
1.8"
14.5"
S I GH T L I NES
RECESSED CEILING
-4-
ConCreTe Pour ConSTruCTion
7.4"
2"
7.1"
LIGHT OPENING
9.8"
OVERALL TRIM
4.5"
11"
3.25"
HOUSING WIDTH
1.8"
J-BOX
14.5"
HOUSING LENGTH
SI G HT L I N E S
RECESSED CEILING
-5-
ConSTruCTion (hiD)
T-Bar / PlaSTer / Drywall / meTal SoFFiT ConSTruCTion
THRU WIRE J-BOX, SPRING LOCKED COVER
4 x 12GA AWG WIRES PLUS GROUNDS ALLOWED
IN & OUT OF J-BOX.
UNIVERSAL MOUNTING BRACKET
4" Max.
1.5" Min.
HOUSING ASSEMBLY
LAMP (BY OTHERS)
LAMPHOLDER
ELECTRICAL TRAY ASSEMBLY
BALLAST AND THERMAL PROTECTOR
ANODIZED REFLECTOR LOW IRIDESCENCE
GASKET
TRIM ASSEMBLY
VANDAL RESISTANT LENS
SPRING NUT, THREADED
GASKET
'O' RING LENS SEAL
STAINLESS STEEL CAP SCREWS (3)
DIE CAST TRIM
TRIM DETAIL
S I GH T L I NES
RECESSED CEILING
-6-
ConCreTe Pour ConSTruCTion (hiD)
CAST JUNCTION BOX, 1/2 NPT PLUGS (3)
4 x 12GA AWG PLUS GROUND ALLOWED
IN & OUT OF J-BOX.
HOUSING ASSEMBLY
LAMP (BY OTHERS)
LAMPHOLDER
ELECTRICAL TRAY ASSEMBLY
BALLAST
ANODIZED REFLECTOR LOW IRIDESCENCE
GASKET
TRIM ASSEMBLY
VANDAL RESISTANT LENS
SPRING NUT, THREADED
GASKET
'O' RING LENS SEAL
STAINLESS STEEL CAP SCREWS (3)
DIE CAST TRIM
TRIM DETAIL
SI G HT L I N E S
RECESSED CEILING
-7-
ConSTruCTion (hollow Ceiling)
mounTing BraCkeT DeTail
1/2" X 1-1/2"
CHANNEL
FURRING STRIP
CHANNEL
1/2" DIA. EMT (X2)
LOCK FOR 3/4"
BAR HANGERS
2-3/32"
POSITION 5/8" - 3/4"
BAR HANGERS
2 POSITIONS FOR
1/2" BAR HANGERS
ACCEPTS #10 CARRIAGE BOLT
TO SECURE BRACKET
LOCK FOR 1/2" BAR
HANGERS
3"
6-1/4"
2-3/32"
S I GH T L I NES
RECESSED CEILING
-8-
inSTallaTion: non-iC - hollow CeilingS (hiD)
Housing
Mounting bars
(optional item)
Lamp
(by others)
J-Box
Electrical
tray
Adjustable
brackets
Reflector
Faceplate
Housing
Ceiling surface
Ceiling
thickness
2.0" max
IMPORTANT
Disconnect power before installing fixtures. Read instructions before
starting work. This product must be installed in accordance with the
applicable installation code by a person familiar with the construction
and operation of the product and the hazards involved.
Sightlines 8000 Series
HOUSING INSTALLATION - NON IC
ELECTRICAL TRAY AND FACEPLATE INSTALLATION
1 Remove housing assembly from shipping container.
1 Remove electrical tray from shipping carton.
2 There must be a 9.0" round opening to accept housing
2 Select required voltage and cap off unused taps.
trim.
3 Position housing in ceiling opening making sure housing trim is flush with ceiling surface. Secure housing to
ceiling joists with mounting bars and adjust mounting
brackets.
4 when installing in suspended t-bar ceiling, secure
mounting bars to main supports and wire to ceiling
members as required.
5 Install supply wiring as per applicable code requirements.
Notes:
These units are listed/certified as non-ic recessed units.
They are meant to be installed with 1/2" space around
the recessed housing, except at point of mounting contact. Insulation must be kept away from housing by a
minimum of 3". The ballasts are thermally protected to
guard against misuse.
3 Install electrical tray to housing assembly with (3) screws provided. Route sleeved wires to j-box. Secure wire to housing
with cable ties (supplied).
4 Connect fixture leads to supply leads and push all through
splices into j-box and attach cover plate.
5 Install reflector with hex nuts.
6 Lamp as required.
7 Remove faceplate assembly with (3) screws (provided). Ceiling surface must be flat to ensure water tight seal.
8 Energize and test as required.
SI G HT L I N E S
REV. 12/09/09
www.rebellelighting.com
© 2010 REBELLE All rights reserved.
REBELLE ARCHITECTURAL LIGHTING 11475 - 201A Street, Maple Ridge, B.C. Canada V2X 0Y3
P 604.465.5739 F 604.465.9801 E info@rebellelighting.com W rebellelighting.com
RECESSED CEILING
-9-
inSTallaTion: ConCreTe Pour (hiD)
Spacing to
center line
Spacing to
center line
Housing
Lamp
(by others)
J-Box
Reflector
Figure 1
Electrical
tray
Faceplate
Housing
J-Box
Concrete form
(by others)
Studs and
wing nuts
IMPORTANT
Figure 2
Disconnect power before installing fixtures. Read instructions before
starting work. This product must be installed in accordance with the
applicable installation code by a person familiar with the construction
and operation of the product and the hazards involved.
Sightlines 8000 Series
HOUSING INSTALLATION - CONCRETE POUR
1 Remove housing from shipping carton. Lay out center
line of luminaire positions on concrete. Form (fig.1)
2 Position template (provided) over marked center line
luminaire spacings (make sure template is level) drill
3/16” holes through form. (Fig.1)
3 Install housing on concrete side of form using 3” long
studs and wing nuts (see fig.2)
4 If other surface treatment is used the housing position
must be adjusted to suit prior to pouring.
5 Install 1/2” NPT conduit as required and pull supply circuit wires per applicable electrical codes.
6 Remove wing nuts and studs after concrete is cured
before the forms are stripped.
S I GH T L I NES
RECESSED CEILING
www.rebellelighting.com
© 2010 REBELLE All rights reserved.
ELECTRICAL TRAY AND FACEPLATE INSTALLATION
1 Remove electrical tray from shipping carton.
2 Select required voltage and cap off unused leads.
3 Install electrical tray to housing assembly with (3) screws provided. Route sleeved wires to j-box. Secure wire to housing
with cable ties (supplied).
4 Connect fixture leads to to supply leads and push all spices
into j-box and attach cover plate.
5 Install reflector with hex nuts.
6 Lamp as required.
7 Remove faceplate assembly from shipping carton.
8 Secure to housing assembly with (3) screws (provided). Ceiling surface must be flat to insure water tight seal.
9 Energize and test as required.
REV. 12/09/09
REBELLE ARCHITECTURAL LIGHTING 11475 - 201A Street, Maple Ridge, B.C. Canada V2X 0Y3
P 604.465.5739 F 604.465.9801 E info@rebellelighting.com W rebellelighting.com
-10-
PhoTomeTriC aPPliCaTion DaTa
70 waTT meTal haliDe
IES INDOOR REPORT
PHOTOMETRIC FILENAME : 8000HID-1.IES
POLAR GRAPH
3197
2398
[TEST] R80001
[TESTLAB] REBELLE
[ISSUEDATE] 05/31/06
[MANUFAC] REBELLE ARCHITECTURAL LIGHTING
[MORE] MAPLE RIDGE, B.C. CANADA
[LUMCAT] 8000-70H
[LUMINAIRE] RECESSED DOWNLIGHT WITH CAST TRIM, CLEAR
[MORE] TEMPERED GLASS AND SPECULAR ALZAK REFLECTOR
1599
2
790
[MORE] LUMEN RATING = 5700 LMS
Total Rated Lamp Lumens
Total Luminaire Efficiency
CIE Type
Spacing Criteria (0-180)
Spacing Criteria (90-270)
Spacing Criteria (Diagonal)
Basic Luminous Shape
Luminous Length (0-180)
Luminous Width (90-270)
Luminous Height
1
Maximum Candela = 3197 Located At Horizontal Angle = 0, Vertical Angle = 5
# 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.)
# 2 - Horizontal Cone Through Vertical Angle (5) (Through Max. Cd.)
5700
70.4 %
Direct
0.98
1.40
1.14
Circular
0.00 ft
0.60 ft (Diameter)
0.00 ft
SI G HT L I N E S
RECESSED CEILING
- 11 -
iSo FooTCanDle PloT
70 waTT meTal haliDe
S I GH T L I NES
RECESSED CEILING
-12-
PhoTomeTriC aPPliCaTion DaTa
2 X 42 waTT ComPaCT FluoreSCenT
IES INDOOR REPORT
PHOTOMETRIC FILENAME : 8000-3.IES
POLAR GRAPH
IES INDOOR REPORT
PHOTOMETRIC FILENAME : 8000-3.IES
2040
DESCRIPTION INFORMATION (From Photometric File)
1530
IESNA:LM-63-1995
[TEST] R80003
[TESTLAB] REBELLE
[ISSUEDATE] 05/31/06
[MANUFAC] REBELLE ARCHITECTURAL LIGHTING
[MORE] MAPLE RIDGE B.C. CANADA
[LUMCAT] 8000-242T
[LUMINAIRE] RECESSED DOWNLIGHT WITH CAST TRIM, CLEAR
[MORE] TEMPERED GLASS AND SPECULAR ALZAK REFLECTOR
[LAMP] TWO 42W TRIPLE TUBE LAMPS
[MORE] LUMEN RATING = 6400 LMS
1020
2
510
CHARACTERISTICS
Total Rated Lamp Lumens
Total Luminaire Efficiency
CIE Type
Spacing Criteria (0-180)
Spacing Criteria (90-270)
Spacing Criteria (Diagonal)
Basic Luminous Shape
Luminous Length (0-180)
Luminous Width (90-270)
Luminous Height
6400 (2 lamps)
55.6 %
Direct
1.52
1.64
1.48
Circular
0.00 ft
0.60 ft (Diameter)
0.00 ft
1
Maximum Candela = 2039.88 Located At Horizontal Angle = 90, Vertical Angle = 17.5
# 1 - Vertical Plane Through Horizontal Angles (90 - 270) (Through Max. Cd.)
# 2 - Horizontal Cone Through Vertical Angle (17.5) (Through Max. Cd.)
IES INDOOR REPORT
PHOTOMETRIC FILENAME : 8000-3.IES
IES INDOOR REPORT
PHOTOMETRIC FILENAME : 8000-3.IES
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
Effective Floor Cavity Reflectance 0.20
ZONAL LUMEN SUMMARY
Zone
Lumens
%Lamp
%Fixt
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
1491.56
2497.93
3552.44
3560.12
0
0
0
0
3560.12
23.3
39
55.5
55.6
0
0
0
0
55.6
41.9
70.2
99.8
100
0
0
0
0
100
Total Luminaire Efficiency = 55.6%
RC
RW
80
70 50 30 10
70
70 50 30 10
50
50 30 10
30
50 30 10
10
50 30 10
0
0
0
1
2
3
4
5
6
7
8
9
10
66
62
59
55
51
48
44
41
39
36
34
65
61
57
53
50
46
43
41
38
36
33
62
57
52
48
44
40
37
34
31
29
27
59
55
51
47
43
39
36
33
31
28
26
57
53
49
45
42
38
35
32
30
28
26
56
51
46
41
37
33
29
27
24
22
20
66
61
55
50
46
42
38
35
32
30
28
66
59
53
47
42
38
34
31
28
26
24
66
58
50
44
39
35
31
28
25
23
21
65
59
54
49
45
41
38
35
32
29
27
65
58
52
46
42
38
34
31
28
26
24
65
57
50
44
39
35
31
28
25
23
21
62
56
50
45
41
37
33
30
28
25
23
62
55
49
43
38
34
31
28
25
23
21
59
54
49
44
40
36
33
30
27
25
23
59
53
48
42
38
34
31
28
25
23
21
57
52
48
43
39
36
33
30
27
25
23
57
52
47
42
37
34
30
28
25
23
21
SI G HT L I N E S
RECESSED CEILING
-13-
iSo FooTCanDle PloT
2 X 42 waTT ComPaCT FluoreSCenT
.5
2
1
.2
.1
10
5
REBELLE ARCHITECTURAL LIGHTING
MAPLE RIDGE B.C. CANADA
8000-242T
RECESSED DOWNLIGHT WITH CAST TRIM, CLEAR
TEMPERED GLASS AND SPECULAR ALZAK
REFLECTOR
TWO 42W TRIPLE TUBE LAMPS
LUMEN RATING = 6400 LMS
Horizontal Footcandles
Scale: 1 Inch = 10 Ft.
Light Loss Factor = 1.00
Total Lumens Per Luminaire = 6400 (2) Lamps
Mounting Height = 10.00 Ft
Maximum Calculated Value = 17.20 Fc
Arrangement: Single
S I GH T L I NES
RECESSED CEILING
-14-
PhoTomeTriC aPPliCaTion DaTa
1 X 42 waTT ComPaCT FluoreSCenT
IES INDOOR REPORT
PHOTOMETRIC FILENAME : 8000-6.IES
POLAR GRAPH
IES INDOOR REPORT
PHOTOMETRIC FILENAME : 8000-6.IES
1257
DESCRIPTION INFORMATION (From Photometric File)
943
IESNA:LM-63-1995
[TEST] R80005
[TESTLAB] REBELLE
[ISSUEDATE] 05/31/06
[MANUFAC] REBELLE ARCHITECTURAL LIGHTING
[MORE] MAPLE RIDGE B.C. CANADA
[LUMCAT] 8000-142T
[LUMINAIRE] RECESSED DOWNLIGHT WITH CAST TRIM, CLEAR
[MORE] TEMPERED GLASS AND SPECULAR ALZAK REFLECTOR
[LAMP] ONE 42W TRIPLE TUBE LAMP
[MORE] LUMEN RATING = 3200 LMS
628
2
314
CHARACTERISTICS
Total Rated Lamp Lumens
Total Luminaire Efficiency
CIE Type
Spacing Criteria (0-180)
Spacing Criteria (90-270)
Spacing Criteria (Diagonal)
Basic Luminous Shape
Luminous Length (0-180)
Luminous Width (90-270)
Luminous Height
3200
68.2 %
Direct
1.60
1.74
1.54
Circular
0.00 ft
0.60 ft (Diameter)
0.00 ft
1
Maximum Candela = 1256.68 Located At Horizontal Angle = 90, Vertical Angle = 17.5
# 1 - Vertical Plane Through Horizontal Angles (90 - 270) (Through Max. Cd.)
# 2 - Horizontal Cone Through Vertical Angle (17.5) (Through Max. Cd.)
IES INDOOR REPORT
PHOTOMETRIC FILENAME : 8000-6.IES
IES INDOOR REPORT
PHOTOMETRIC FILENAME : 8000-6.IES
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
Effective Floor Cavity Reflectance 0.20
ZONAL LUMEN SUMMARY
Zone
Lumens
%Lamp
%Fixt
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
870.19
1492.42
2161.02
2182.88
0
0
0
0
2182.88
27.2
46.6
67.5
68.2
0
0
0
0
68.2
39.9
68.4
99
100
0
0
0
0
100
Total Luminaire Efficiency = 68.2%
RC
RW
80
70 50 30 10
70
70 50 30 10
50
50 30 10
30
50 30 10
10
50 30 10
0
0
0
1
2
3
4
5
6
7
8
9
10
81
76
71
67
62
58
54
50
47
44
41
79
75
70
65
61
57
53
49
46
43
40
76
70
64
58
53
49
45
41
38
35
32
73
67
62
57
52
47
43
40
37
34
32
70
65
60
55
50
46
42
39
36
33
31
68
62
55
49
44
39
35
32
29
26
24
81
74
67
61
56
51
46
42
39
36
33
81
72
64
57
51
46
41
37
34
31
28
81
70
61
54
47
42
38
34
30
28
25
79
73
66
60
55
50
46
42
38
36
33
79
71
63
56
50
45
41
37
34
31
28
79
69
60
53
47
42
37
34
30
28
25
76
68
61
55
49
45
40
37
33
30
28
76
67
59
52
46
41
37
33
30
27
25
73
66
60
54
48
44
40
36
33
30
28
73
65
58
51
46
41
37
33
30
27
25
70
64
58
53
48
43
39
36
33
30
27
70
63
57
51
45
41
37
33
30
27
25
SI G HT L I N E S
RECESSED CEILING
-15-
iSo FooTCanDle PloT
1 X 42 waTT ComPaCT FluoreSCenT
.5
10
1
.2
.1
2
5
REBELLE ARCHITECTURAL LIGHTING
MAPLE RIDGE B.C. CANADA
8000-142T
RECESSED DOWNLIGHT WITH CAST TRIM, CLEAR
TEMPERED GLASS AND SPECULAR ALZAK
REFLECTOR
ONE 42W TRIPLE TUBE LAMP
LUMEN RATING = 3200 LMS
Horizontal Footcandles
Scale: 1 Inch = 10 Ft.
Light Loss Factor = 1.00
Total Lumens Per Luminaire = 3200
Mounting Height = 10.00 Ft
Maximum Calculated Value = 10.53 Fc
Arrangement: Single
S I GH T L I NES
RECESSED CEILING
-16-
PainT FiniSheS
Powder Coat Paint
Eight Standard Colors
The colors shown below are available for all Rebelle
products and are suitable for interior and exterior use.
other colors are available to match RAL standards, or
to match a specific color sample. Both RAL and color
match are premium priced color options.
WS
WT
AN
SM
GM
BT
BM
BZ
satin white
textured
white
natural
aluminium
metallic
silver
gunmetal
textured
black
black matte
textured
bronze
Surface Preparation and Application Process
Rebelle’s powder painting process utilizes only polyester powders
welded assemblies are shot blasted to near white specifications prior
to ensure durability and permanence in outdoor applications. The
to the five stage pre-treatment process. Following pre-treatment, all
process follows a documented quality assurance procedure to ensure
parts are coated using an electrostatic process to allow for a consistent,
the longevity of the finish in the most rigorous climates. All of Rebelle’s
even coating on parts. After coating, parts are then transferred to cure
luminaires go through a five-stage chemical pre-treatment prior to
in a high temperature oven. Paint production samples are continually
paint application in order to remove all surface impurities. To allow
checked to ensure they adhere to strictly controlled quality standards.
for a consistent, even coating on parts, all heavy cast aluminum and
SI G HT L I N E S
RECESSED CEILING
-17-
REBELLE ARCHITECTURAL LIGHTING
11475 - 201A Street, Maple Ridge, B.C, Canada V2X 0Y3
P 604.465.5739 F 604.465.9801
E info@rebellelighting.com W rebellelighting.com