Sightlines R10.1 TECHNICAL MANUAL Recessed Ceiling Recessed Downlight/Vandal Resistant CONCEPT VANDAL RESISTANT RECESSED DowNLIGHT The Sightlines 8000 Recessed Downlight Series is a premium quality, vandal resistant recessed downlight designed for exterior canopies and soffits. The luminaire design matches indoor open reflector downlights in appearance to provide visual uniformity between the building exterior and interior. Available in two constructions - a specific concrete pour design and a standard non insulated ceiling version for inverted T-bar, drywall, wet ceiling and metal ceiling constructions. All units are “wet location” labeled with an ingress protection level equivalent to IP 55. The Sightlines 8000 Series provide the maximum vandal resistance to protect recessed lighting installations in exposed public areas. S I GH T L I NES RECESSED CEILING -2- The SighTlineS Family R ecessed c eiling The Sightlines 8000 Recessed Downlight Series comes in two constructions - a specific concrete pour design and a standard non insulated ceiling version for inverted T-bar, drywall, wet ceiling and metal ceiling constructions. The optical system is designed to accommodate horizontal compact fluorescent and metal halide, medium base lamps. The specular reflector is formed from high purity aluminum sheet that is polished, buffed and anodized to provide a low iridescent finish. Hollow Ceiling CF 8000 8000CG Hollow Ceiling Concrete Pour Concrete Pour HID 8000 8000CG Concrete Pour Hollow Ceiling SI G HT L I N E S RECESSED CEILING -3- DimenSionS T-Bar / PlaSTer / Drywall / meTal SoFFiT ConSTruCTion 7.4" 2" CLEARANCE RECESSED DEPTH 7.1" LIGHT OPENING 9.0" CEILING CUT OUT 9.8" OVERALL TRIM 2.09" 11" 5.25" 2.88" 2.09" 1.8" 14.5" S I GH T L I NES RECESSED CEILING -4- ConCreTe Pour ConSTruCTion 7.4" 2" 7.1" LIGHT OPENING 9.8" OVERALL TRIM 4.5" 11" 3.25" HOUSING WIDTH 1.8" J-BOX 14.5" HOUSING LENGTH SI G HT L I N E S RECESSED CEILING -5- ConSTruCTion (hiD) T-Bar / PlaSTer / Drywall / meTal SoFFiT ConSTruCTion THRU WIRE J-BOX, SPRING LOCKED COVER 4 x 12GA AWG WIRES PLUS GROUNDS ALLOWED IN & OUT OF J-BOX. UNIVERSAL MOUNTING BRACKET 4" Max. 1.5" Min. HOUSING ASSEMBLY LAMP (BY OTHERS) LAMPHOLDER ELECTRICAL TRAY ASSEMBLY BALLAST AND THERMAL PROTECTOR ANODIZED REFLECTOR LOW IRIDESCENCE GASKET TRIM ASSEMBLY VANDAL RESISTANT LENS SPRING NUT, THREADED GASKET 'O' RING LENS SEAL STAINLESS STEEL CAP SCREWS (3) DIE CAST TRIM TRIM DETAIL S I GH T L I NES RECESSED CEILING -6- ConCreTe Pour ConSTruCTion (hiD) CAST JUNCTION BOX, 1/2 NPT PLUGS (3) 4 x 12GA AWG PLUS GROUND ALLOWED IN & OUT OF J-BOX. HOUSING ASSEMBLY LAMP (BY OTHERS) LAMPHOLDER ELECTRICAL TRAY ASSEMBLY BALLAST ANODIZED REFLECTOR LOW IRIDESCENCE GASKET TRIM ASSEMBLY VANDAL RESISTANT LENS SPRING NUT, THREADED GASKET 'O' RING LENS SEAL STAINLESS STEEL CAP SCREWS (3) DIE CAST TRIM TRIM DETAIL SI G HT L I N E S RECESSED CEILING -7- ConSTruCTion (hollow Ceiling) mounTing BraCkeT DeTail 1/2" X 1-1/2" CHANNEL FURRING STRIP CHANNEL 1/2" DIA. EMT (X2) LOCK FOR 3/4" BAR HANGERS 2-3/32" POSITION 5/8" - 3/4" BAR HANGERS 2 POSITIONS FOR 1/2" BAR HANGERS ACCEPTS #10 CARRIAGE BOLT TO SECURE BRACKET LOCK FOR 1/2" BAR HANGERS 3" 6-1/4" 2-3/32" S I GH T L I NES RECESSED CEILING -8- inSTallaTion: non-iC - hollow CeilingS (hiD) Housing Mounting bars (optional item) Lamp (by others) J-Box Electrical tray Adjustable brackets Reflector Faceplate Housing Ceiling surface Ceiling thickness 2.0" max IMPORTANT Disconnect power before installing fixtures. Read instructions before starting work. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Sightlines 8000 Series HOUSING INSTALLATION - NON IC ELECTRICAL TRAY AND FACEPLATE INSTALLATION 1 Remove housing assembly from shipping container. 1 Remove electrical tray from shipping carton. 2 There must be a 9.0" round opening to accept housing 2 Select required voltage and cap off unused taps. trim. 3 Position housing in ceiling opening making sure housing trim is flush with ceiling surface. Secure housing to ceiling joists with mounting bars and adjust mounting brackets. 4 when installing in suspended t-bar ceiling, secure mounting bars to main supports and wire to ceiling members as required. 5 Install supply wiring as per applicable code requirements. Notes: These units are listed/certified as non-ic recessed units. They are meant to be installed with 1/2" space around the recessed housing, except at point of mounting contact. Insulation must be kept away from housing by a minimum of 3". The ballasts are thermally protected to guard against misuse. 3 Install electrical tray to housing assembly with (3) screws provided. Route sleeved wires to j-box. Secure wire to housing with cable ties (supplied). 4 Connect fixture leads to supply leads and push all through splices into j-box and attach cover plate. 5 Install reflector with hex nuts. 6 Lamp as required. 7 Remove faceplate assembly with (3) screws (provided). Ceiling surface must be flat to ensure water tight seal. 8 Energize and test as required. SI G HT L I N E S REV. 12/09/09 www.rebellelighting.com © 2010 REBELLE All rights reserved. REBELLE ARCHITECTURAL LIGHTING 11475 - 201A Street, Maple Ridge, B.C. Canada V2X 0Y3 P 604.465.5739 F 604.465.9801 E info@rebellelighting.com W rebellelighting.com RECESSED CEILING -9- inSTallaTion: ConCreTe Pour (hiD) Spacing to center line Spacing to center line Housing Lamp (by others) J-Box Reflector Figure 1 Electrical tray Faceplate Housing J-Box Concrete form (by others) Studs and wing nuts IMPORTANT Figure 2 Disconnect power before installing fixtures. Read instructions before starting work. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Sightlines 8000 Series HOUSING INSTALLATION - CONCRETE POUR 1 Remove housing from shipping carton. Lay out center line of luminaire positions on concrete. Form (fig.1) 2 Position template (provided) over marked center line luminaire spacings (make sure template is level) drill 3/16” holes through form. (Fig.1) 3 Install housing on concrete side of form using 3” long studs and wing nuts (see fig.2) 4 If other surface treatment is used the housing position must be adjusted to suit prior to pouring. 5 Install 1/2” NPT conduit as required and pull supply circuit wires per applicable electrical codes. 6 Remove wing nuts and studs after concrete is cured before the forms are stripped. S I GH T L I NES RECESSED CEILING www.rebellelighting.com © 2010 REBELLE All rights reserved. ELECTRICAL TRAY AND FACEPLATE INSTALLATION 1 Remove electrical tray from shipping carton. 2 Select required voltage and cap off unused leads. 3 Install electrical tray to housing assembly with (3) screws provided. Route sleeved wires to j-box. Secure wire to housing with cable ties (supplied). 4 Connect fixture leads to to supply leads and push all spices into j-box and attach cover plate. 5 Install reflector with hex nuts. 6 Lamp as required. 7 Remove faceplate assembly from shipping carton. 8 Secure to housing assembly with (3) screws (provided). Ceiling surface must be flat to insure water tight seal. 9 Energize and test as required. REV. 12/09/09 REBELLE ARCHITECTURAL LIGHTING 11475 - 201A Street, Maple Ridge, B.C. Canada V2X 0Y3 P 604.465.5739 F 604.465.9801 E info@rebellelighting.com W rebellelighting.com -10- PhoTomeTriC aPPliCaTion DaTa 70 waTT meTal haliDe IES INDOOR REPORT PHOTOMETRIC FILENAME : 8000HID-1.IES POLAR GRAPH 3197 2398 [TEST] R80001 [TESTLAB] REBELLE [ISSUEDATE] 05/31/06 [MANUFAC] REBELLE ARCHITECTURAL LIGHTING [MORE] MAPLE RIDGE, B.C. CANADA [LUMCAT] 8000-70H [LUMINAIRE] RECESSED DOWNLIGHT WITH CAST TRIM, CLEAR [MORE] TEMPERED GLASS AND SPECULAR ALZAK REFLECTOR 1599 2 790 [MORE] LUMEN RATING = 5700 LMS Total Rated Lamp Lumens Total Luminaire Efficiency CIE Type Spacing Criteria (0-180) Spacing Criteria (90-270) Spacing Criteria (Diagonal) Basic Luminous Shape Luminous Length (0-180) Luminous Width (90-270) Luminous Height 1 Maximum Candela = 3197 Located At Horizontal Angle = 0, Vertical Angle = 5 # 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (5) (Through Max. Cd.) 5700 70.4 % Direct 0.98 1.40 1.14 Circular 0.00 ft 0.60 ft (Diameter) 0.00 ft SI G HT L I N E S RECESSED CEILING - 11 - iSo FooTCanDle PloT 70 waTT meTal haliDe S I GH T L I NES RECESSED CEILING -12- PhoTomeTriC aPPliCaTion DaTa 2 X 42 waTT ComPaCT FluoreSCenT IES INDOOR REPORT PHOTOMETRIC FILENAME : 8000-3.IES POLAR GRAPH IES INDOOR REPORT PHOTOMETRIC FILENAME : 8000-3.IES 2040 DESCRIPTION INFORMATION (From Photometric File) 1530 IESNA:LM-63-1995 [TEST] R80003 [TESTLAB] REBELLE [ISSUEDATE] 05/31/06 [MANUFAC] REBELLE ARCHITECTURAL LIGHTING [MORE] MAPLE RIDGE B.C. CANADA [LUMCAT] 8000-242T [LUMINAIRE] RECESSED DOWNLIGHT WITH CAST TRIM, CLEAR [MORE] TEMPERED GLASS AND SPECULAR ALZAK REFLECTOR [LAMP] TWO 42W TRIPLE TUBE LAMPS [MORE] LUMEN RATING = 6400 LMS 1020 2 510 CHARACTERISTICS Total Rated Lamp Lumens Total Luminaire Efficiency CIE Type Spacing Criteria (0-180) Spacing Criteria (90-270) Spacing Criteria (Diagonal) Basic Luminous Shape Luminous Length (0-180) Luminous Width (90-270) Luminous Height 6400 (2 lamps) 55.6 % Direct 1.52 1.64 1.48 Circular 0.00 ft 0.60 ft (Diameter) 0.00 ft 1 Maximum Candela = 2039.88 Located At Horizontal Angle = 90, Vertical Angle = 17.5 # 1 - Vertical Plane Through Horizontal Angles (90 - 270) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (17.5) (Through Max. Cd.) IES INDOOR REPORT PHOTOMETRIC FILENAME : 8000-3.IES IES INDOOR REPORT PHOTOMETRIC FILENAME : 8000-3.IES COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180 1491.56 2497.93 3552.44 3560.12 0 0 0 0 3560.12 23.3 39 55.5 55.6 0 0 0 0 55.6 41.9 70.2 99.8 100 0 0 0 0 100 Total Luminaire Efficiency = 55.6% RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 0 1 2 3 4 5 6 7 8 9 10 66 62 59 55 51 48 44 41 39 36 34 65 61 57 53 50 46 43 41 38 36 33 62 57 52 48 44 40 37 34 31 29 27 59 55 51 47 43 39 36 33 31 28 26 57 53 49 45 42 38 35 32 30 28 26 56 51 46 41 37 33 29 27 24 22 20 66 61 55 50 46 42 38 35 32 30 28 66 59 53 47 42 38 34 31 28 26 24 66 58 50 44 39 35 31 28 25 23 21 65 59 54 49 45 41 38 35 32 29 27 65 58 52 46 42 38 34 31 28 26 24 65 57 50 44 39 35 31 28 25 23 21 62 56 50 45 41 37 33 30 28 25 23 62 55 49 43 38 34 31 28 25 23 21 59 54 49 44 40 36 33 30 27 25 23 59 53 48 42 38 34 31 28 25 23 21 57 52 48 43 39 36 33 30 27 25 23 57 52 47 42 37 34 30 28 25 23 21 SI G HT L I N E S RECESSED CEILING -13- iSo FooTCanDle PloT 2 X 42 waTT ComPaCT FluoreSCenT .5 2 1 .2 .1 10 5 REBELLE ARCHITECTURAL LIGHTING MAPLE RIDGE B.C. CANADA 8000-242T RECESSED DOWNLIGHT WITH CAST TRIM, CLEAR TEMPERED GLASS AND SPECULAR ALZAK REFLECTOR TWO 42W TRIPLE TUBE LAMPS LUMEN RATING = 6400 LMS Horizontal Footcandles Scale: 1 Inch = 10 Ft. Light Loss Factor = 1.00 Total Lumens Per Luminaire = 6400 (2) Lamps Mounting Height = 10.00 Ft Maximum Calculated Value = 17.20 Fc Arrangement: Single S I GH T L I NES RECESSED CEILING -14- PhoTomeTriC aPPliCaTion DaTa 1 X 42 waTT ComPaCT FluoreSCenT IES INDOOR REPORT PHOTOMETRIC FILENAME : 8000-6.IES POLAR GRAPH IES INDOOR REPORT PHOTOMETRIC FILENAME : 8000-6.IES 1257 DESCRIPTION INFORMATION (From Photometric File) 943 IESNA:LM-63-1995 [TEST] R80005 [TESTLAB] REBELLE [ISSUEDATE] 05/31/06 [MANUFAC] REBELLE ARCHITECTURAL LIGHTING [MORE] MAPLE RIDGE B.C. CANADA [LUMCAT] 8000-142T [LUMINAIRE] RECESSED DOWNLIGHT WITH CAST TRIM, CLEAR [MORE] TEMPERED GLASS AND SPECULAR ALZAK REFLECTOR [LAMP] ONE 42W TRIPLE TUBE LAMP [MORE] LUMEN RATING = 3200 LMS 628 2 314 CHARACTERISTICS Total Rated Lamp Lumens Total Luminaire Efficiency CIE Type Spacing Criteria (0-180) Spacing Criteria (90-270) Spacing Criteria (Diagonal) Basic Luminous Shape Luminous Length (0-180) Luminous Width (90-270) Luminous Height 3200 68.2 % Direct 1.60 1.74 1.54 Circular 0.00 ft 0.60 ft (Diameter) 0.00 ft 1 Maximum Candela = 1256.68 Located At Horizontal Angle = 90, Vertical Angle = 17.5 # 1 - Vertical Plane Through Horizontal Angles (90 - 270) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (17.5) (Through Max. Cd.) IES INDOOR REPORT PHOTOMETRIC FILENAME : 8000-6.IES IES INDOOR REPORT PHOTOMETRIC FILENAME : 8000-6.IES COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180 870.19 1492.42 2161.02 2182.88 0 0 0 0 2182.88 27.2 46.6 67.5 68.2 0 0 0 0 68.2 39.9 68.4 99 100 0 0 0 0 100 Total Luminaire Efficiency = 68.2% RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 0 1 2 3 4 5 6 7 8 9 10 81 76 71 67 62 58 54 50 47 44 41 79 75 70 65 61 57 53 49 46 43 40 76 70 64 58 53 49 45 41 38 35 32 73 67 62 57 52 47 43 40 37 34 32 70 65 60 55 50 46 42 39 36 33 31 68 62 55 49 44 39 35 32 29 26 24 81 74 67 61 56 51 46 42 39 36 33 81 72 64 57 51 46 41 37 34 31 28 81 70 61 54 47 42 38 34 30 28 25 79 73 66 60 55 50 46 42 38 36 33 79 71 63 56 50 45 41 37 34 31 28 79 69 60 53 47 42 37 34 30 28 25 76 68 61 55 49 45 40 37 33 30 28 76 67 59 52 46 41 37 33 30 27 25 73 66 60 54 48 44 40 36 33 30 28 73 65 58 51 46 41 37 33 30 27 25 70 64 58 53 48 43 39 36 33 30 27 70 63 57 51 45 41 37 33 30 27 25 SI G HT L I N E S RECESSED CEILING -15- iSo FooTCanDle PloT 1 X 42 waTT ComPaCT FluoreSCenT .5 10 1 .2 .1 2 5 REBELLE ARCHITECTURAL LIGHTING MAPLE RIDGE B.C. CANADA 8000-142T RECESSED DOWNLIGHT WITH CAST TRIM, CLEAR TEMPERED GLASS AND SPECULAR ALZAK REFLECTOR ONE 42W TRIPLE TUBE LAMP LUMEN RATING = 3200 LMS Horizontal Footcandles Scale: 1 Inch = 10 Ft. Light Loss Factor = 1.00 Total Lumens Per Luminaire = 3200 Mounting Height = 10.00 Ft Maximum Calculated Value = 10.53 Fc Arrangement: Single S I GH T L I NES RECESSED CEILING -16- PainT FiniSheS Powder Coat Paint Eight Standard Colors The colors shown below are available for all Rebelle products and are suitable for interior and exterior use. other colors are available to match RAL standards, or to match a specific color sample. Both RAL and color match are premium priced color options. WS WT AN SM GM BT BM BZ satin white textured white natural aluminium metallic silver gunmetal textured black black matte textured bronze Surface Preparation and Application Process Rebelle’s powder painting process utilizes only polyester powders welded assemblies are shot blasted to near white specifications prior to ensure durability and permanence in outdoor applications. The to the five stage pre-treatment process. Following pre-treatment, all process follows a documented quality assurance procedure to ensure parts are coated using an electrostatic process to allow for a consistent, the longevity of the finish in the most rigorous climates. All of Rebelle’s even coating on parts. After coating, parts are then transferred to cure luminaires go through a five-stage chemical pre-treatment prior to in a high temperature oven. Paint production samples are continually paint application in order to remove all surface impurities. To allow checked to ensure they adhere to strictly controlled quality standards. for a consistent, even coating on parts, all heavy cast aluminum and SI G HT L I N E S RECESSED CEILING -17- REBELLE ARCHITECTURAL LIGHTING 11475 - 201A Street, Maple Ridge, B.C, Canada V2X 0Y3 P 604.465.5739 F 604.465.9801 E info@rebellelighting.com W rebellelighting.com