4400 Install Guide 4000 SERIES: 4000 WOOD TILES STYLE: 4400 TORSION SPRING TILE Attention Prior to installation, ambient temperatures and humidity must be maintained at the levels intended for the project when occupied. Please refer to the 9Wood “Wood Ceiling Acclimatization for Professionals” handbook, the “A Not-So-Dry Look at Wood Acclimatization” DVD, and AWI standards. Wood Ceiling Acclim atization for Professionals 999 South A Street | Spring field OR 97477 USA | 888.76 7.9990 | www.9 wood.c om Ceiling Accessories Supplied by 9Wood Supplied by Others Wood Tiles with Torsion Spring Brackets 9Wood Torsion Springs 9Wood Butterfly Brackets (Double and/or Single) Black scrim backing (when specified) Stiffening bars (when required) Matching edge tape and/or lacquer finish (for touch-up; when required) Shop drawings (when applicable) Supplemental stain/clear finish/FR treatment. T-bar mainrunners (15/16” heavy duty) T-bar crosstees Hanger wire Wall angle Fasteners and hardware Tools for installation and/or field cutting Cleaning supplies (dust cloth, polish, etc.) 9Wood, Inc. Install Guide 4400 Torsion Spring Tiles — 2 rev. 09/04/2013 Suspension Step 1 – Reference Grid Establish reference point for the suspension grid (i.e. point A wall, point B center point or other fixed point; see Fig. 1). Index the suspension grid off of the reference point. Note: Shop Drawings or Cut Sheets may offer a recommended reference point. Step 2 – Install Grid 4’ x 4’ (nominal) wood tiles require 15/16” heavy duty t-bar mainrunners and cross tees to be installed at 4’-0” on center (see Fig. 2). Hanger wires are to be installed according to local codes and seismic requirements. Figure 1 Figure 2 Installation Step 3 – Wood Tile Details The 9Wood Wood Tile uses 9Wood Torsion Springs and Torsion Spring Brackets for attachment to the heavy duty T-bar Grid suspension system. (see Fig. 3 and 4). Figure 3 999 South A Street Springfield, OR 97477 Figure 4 tel 888.767.9990 fax 888.767.9998 sales@9wood.com www.9wood.com 9Wood, Inc. Install Guide 4400 Torsion Spring Tiles — 3 rev. 09/04/2013 Step 4 – Butterfly Bracket The 9Wood Torsion Spring Wood Tile ceiling system uses 9Wood Butterfly Brackets for attaching the wood tiles to the heavy duty T-bar Grid suspension system. Place the Butterfly Brackets over the t-bar mainrunner where they will align with the torsion springs on the wood tiles (may require initial attachment and adjustment). Use a #8 fastener to attach the Brackets to the t-bar mainrunner (see Fig. 5). Figure 5 Step 5 – Location: Bring the Wood Tile up to the face of the grid system in its proper location (refer to Shop Drawings for locations). Locate the slots in the 9Wood Butterfly Bracket that align with the Torsion Springs on the Wood Tile. (see Fig. 6). Figure 6 Step 6 – Compress Torsion Spring Next, pinch the Torsion Springs together to allow them to pass thru the slot in the Butterfly Bracket (see Fig 7). It is recommended to start at one end of the Tile and work toward the opposite end. Figure 7 999 South A Street Springfield, OR 97477 tel 888.767.9990 fax 888.767.9998 sales@9wood.com www.9wood.com 9Wood, Inc. Install Guide 4400 Torsion Spring Tiles — 4 rev. 09/04/2013 Step 7 – Attachment Next, slide the Torsion Springs thru the slot in the Butterfly Bracket (see Fig 8) and release the tension on the springs. This will allow the “hook” on the Torsion Springs to rest on the bracket and hang freely just below the suspension system. Figure 8 Step 8 – Wood Tile Alignment Once all of the Torsion Springs have been attached to the Butterfly Brackets above, push the panel up into place. The tension from the Torsion Springs will hold the Wood Tile in place (see Fig 9). Adjustments may be required to obtain desired reveals. Figure 9 Step 9 – Continuing Installation Continue to install the Torsion Spring Wood Tiles toward the perimeter on the opposite side of the ceiling field. Adjustments may be required to obtain desired reveals (see Fig. 10). Figure 10 999 South A Street Springfield, OR 97477 tel 888.767.9990 fax 888.767.9998 sales@9wood.com www.9wood.com 9Wood, Inc. Install Guide 4400 Torsion Spring Tiles — 5 rev. 09/04/2013 Step 10 – Perimeters Some perimeters will require field cutting of the Wood Tiles. It may be required to relocate the Butterfly Brackets after field cutting (see Fig. 11). The field cuts will need to be field finished (see Finishing Field Conditions below) or concealed by shadow molding (not shown; supplied by others). Figure 11 Finishing Field Conditions Veneer Products Applying matching edgebanding, stain and or clear satin lacquer finish to field cut/field ripped edges may be required. Final Dust / Clean Prior to installation or after installation wood members should be dusted. Use a dry dust cloth to clean members. Do not use cleaning chemicals or wet cloths. Aerosol furniture polishes that will not affect the sheen can be used with appropriate caution to remove greasy finger prints if “white gloves” were not used during handling. Do not spray directly on the wood surface. Apply small amounts on a soft cloth and rub gently. Minor surface scuffing or scratches can be removed by lightly rubbing the affect area with a dry, clean steel wool (#0000). Do not over apply. 999 South A Street Springfield, OR 97477 tel 888.767.9990 fax 888.767.9998 sales@9wood.com www.9wood.com