CCD7_Flyer 2/7/07 9:32 AM Page 1 4509 Springfield Street Dayton, OH 45431 Phone: 937.253.2000 www.lauparts.com A Perfect Solution to a Variety of Applications The CCD7 Advantage Lau's CCD7 is the most versatile ceiling damper in the industry. With multiple ways to install the CCD7, there's almost no way to install it wrong Use your own boot or plenum, or order with a factory-installed boot or plenum, for maximum convenience The damper may be installed before or after the gypsum board is installed Refer to Lau's UL approved installation instructions for more information Important Note: The applications shown below are UL555C listed installations; other manufacturers refer to ARL (Applied Research Laboratories) or Warnock Hersey labeled products for different installations and applications. Save time and money with Lau’s CCD7 Damper! (Accessories shown below are also available to help meet any requirement.) Installation Instructions Lau CCD7 Pottorff CFD-521 Nailor Type 0755 Lloyds CRD50-BT Crown CRD50 Return Air Plenum (ductless) N/A N/A N/A N/A 90º Boot N/A N/A N/A N/A Straight Boot N/A N/A N/A N/A End Boot N/A N/A N/A N/A Through Ceiling Membrane Penetration N/A N/A N/A N/A Steel Plenum Box N/A Ductboard Plenum Box N/A Steel Insulated Plenum Box N/A The versatility of Lau’s CCD7 dampers will allow you to save both time and money! CCD7_Flyer 2/7/07 9:32 AM Page 2 4509 Springfield Street Dayton, OH 45431 Phone: 937.253.2000 www.lauparts.com A Perfect Solution to a Variety of Applications Ceiling Radiation Dampers Ceiling Components Floor/Ceiling and Roof/Ceiling Comparison Chart ANSI/UL 263 L528 Lau CCD7 L586 Pottorff CFD-521 L521 Nailor Type 0755 L550 Lloyds CRD50-BT L563 Crown CRD50 L563 Fire Resistence Rating (Hours) 1 Hr. 1 Hr. 1 Hr. 1 Hr. 1 Hr. 1 Hr. Trusses No Penetrations Allowed* Similar to L528 Similar to L528 Similar to L528 Similar to L528 Similar to L528 Gypsum Board One Layer Required Similar to L528 Similar to L528 Similar to L528 Similar to L528 Similar to L528 Similar to L528 Similar to L528 Similar to L528 Similar to L528 Similar to L528 Damper only; Plenum box not required Damper in steel; Plenum box required Damper in insulated; Steel plenum box required Damper in insulated; Steel plenum box required Damper in insulated; Steel plenum box required Multiple Layers Optional Steel Framing Furring channels, or Members resilient channels, or (Furring Channels) steel framing (Resilient Channels) members Ceiling Radiation Damper No damper allowed Air Duct None Not required Class 0 or 1 Class 0 or 1 Class 0 or 1 Class 0 or 1 Grill None Not required Steel grill Steel grill Steel grill Steel grill Membrane Penetration No Yes No No No No Save time and money with Lau’s CCD7 Damper! (Accessories shown below are also available to help meet any requirement.) * Parallel cord truss, spaced a mx. 24 inches; C-C fabricated from nom 2 by 4 inch lumber- with lumber orientated vertcally or horizontally; Min truss depth is 18 inches UL Wood Joist Assemblies Comparison Chart Construction ANSI/UL 263 L501 Lau CCD7 L501* Pottorff CFD-521 Nailor Type 0755 Lloyds CRD50-BT Crown CRD50 Hour Rating 1 Hr. 1 Hr. N/A N/A N/A N/A Damper Details See design Damper with insulated box N/A N/A N/A N/A Wood Joist Wood joist Min. 2” x 10” spaced on 16” C-C. Brdiging or blocking required. Same as L501 N/A N/A N/A N/A Gypsum Board One layer required 5/8” thick Type C Gypsum; Multiple layers optional Same as L501 N/A N/A N/A N/A Air Duct See design Class 0 or 1 N/A N/A N/A N/A Grill See design Steel grill N/A N/A N/A N/A * Lau’s CCD7 is also UL listed for wood joist ceiling designs L502, L503, L506, L507, L508, L512, L513, L514, L515, L516, L517, L518, L519, L522, L523, L533, L535, L537 and L545. ** Lau’s CCD7 is the only ceiling radiation damper that is UL listed for steel joint assemblies (design L524.) The versatility of Lau’s CCD7 dampers will allow you to save both time and money! LAD1778-0107