Reference guide Small projects products For panelboards, surge protection, transformers and switches Table of Contents Enclosures Inside Cover Branch Breakers Breaker Mountings Kits Accessories/Lugs Miscellaneous Parts Retrofit Kit Surge Protection Transformers General Duty Safety Switches Heavy Duty Safety Switches Safety Switch Accessories Type P1 Unassembled Panelboards Enclosures 1 Type 1 Height Inches Trim Surface Flush Boxes Type 3R/12 32 38 44 50 62 68 S32B S38B S44B S50B S62B S68B F32B F38B F44B F50B F62B F68B B32 B38 B44 B50 B62 B68 WP32 WP38 WP44 WP50 WP62 WP68 74 S74B F74B B74 WP74 2, 3 18 Circuit 400A panels are not available with Revised P1. 54 Circuit Panels are available for both 250A and 400A. 66 circuit panels are available as Factory assembled only if needed 2 3R/12 enclosures are complete and do not require a trim. 3 Enclosure height is directly related to the P1 panel maximum amperage and branch circuits (poles). P1 250 amp maximum can heights are 32”, 38”, 44” and 50” respectfully. P1 400 amp maximum panels heights are 62”, 68” and 74” for 30, 42 and 54 circuit panels respectfully. 1 Type P1 Unassembled Panelboards Interiors only – Less branch breakers 1 Phase, 3 Wire Ampere Rating Max. No. Mains of Poles 18 30 250 42 54 30 400 42 54 18 30 250 42 54 30 400 42 54 3 Phase, 4 Wire 18 30 250 42 54 30 400 42 54 18 30 250 42 54 30 400 42 54 3 Phase, 4 Wire 18 30 250 42 54 30 400 42 54 18 30 250 42 54 30 400 42 54 120/240V Interiors P1A18MC250AT P1A30MC250AT P1A42MC250AT P1A54MC250AT P1A30MC400AT P1A42MC400AT P1A54MC400AT P1A18MC250CT P1A30MC250CT P1A42MC250CT P1A54MC250CT P1A30MC400CT P1A42MC400CT P1A54MC400CT Material Aluminum Aluminum Copper Copper 208Y/120V P1X18MC250AT P1X30MC250AT P1X42MC250AT P1X54MC250AT P1X30MC400AT P1X42MC400AT P1X54MC400AT P1X18MC250CT P1X30MC250CT P1X42MC250CT P1X54MC250CT P1X30MC400CT P1X42MC400CT P1X54MC400CT Aluminum Aluminum Copper Copper 480Y/277V P1E18MC250AT P1E30MC250AT P1E42MC250AT P1E54MC250AT P1E30MC400AT P1E42MC400AT P1E54MC400AT P1E18MC250CT P1E30MC250CT P1E42MC250CT P1E54MC250CT P1E30MC400CT P1E42MC400CT P1E54MC400CT Aluminum Aluminum Copper Copper Type P1 Unassembled Panelboards Interiors only, for xGB Breakers – Less Branch Breakers Ampere Rating Mains 250 250 400 400 Max. No. of Poles 18 30 42 54 18 30 42 54 30 42 54 30 42 54 Interiors P1718MC250AT P1730MC250AT P1742MC250AT P1754MC250AT P1718MC250CT P1730MC250CT P1742MC250CT P1754MC250CT P1730MC400AT P1742MC400AT P1754MC400AT P1730MC400CT P1742MC400CT P1754MC400CT Material Aluminum Copper Aluminum Copper Branch Breakers Selection for P1 BL Branch Breakers – 10,000A IR Amp Rating 15 20 25 30 35 40 45 50 55 60 70 80 90 100 1-Pole 120/240V B115 B120 B125 B130 B135 B140 B145 B150 B155 B160 B170 — — — 2-Pole 120/240V B215 B220 B225 B230 B235 B240 B245 B250 — B260 B270 B280 B290 B2100 2-Pole 240V B215R B220R B225R B230R B235R B240R B245R B250R — — — — — — 3-Pole 240V B315 B320 B325 B330 B335 B340 B345 B350 — B360 B370 B380 B390 B3100 BLH Branch Breakers – 22,000A IR Amp Rating 15 20 25 30 40 50 55 60 70 80 90 100 1-Pole 120/240V B115H B120H B125H B130H B140H B150H B155H B160H B170H — — — 2-Pole 120/240V B215H B220H B225H B230H B240H B250H — B260H B270H B280H B290H B2100H 3-Pole 240V B315H B320H B325H B330H B340H B350H — B360H B370H B380H B390H B3100H HBL Branch Breakers – 65,000A IR 15 20 30 40 50 60 70 80 90 100 B115HH B120HH B130HH B140HH B150HH — — — — — B215HH B220HH B230HH B240HH B250HH B260HH B270HH B280HH B290HH B2100HH B315HH B320HH B330HH B340HH B350HH B360HH B370HH B380HH B390HH B3100HH BQD Branch Breakers 14,000A IR Max. @ 480/277V AC / 65,000A IR max. @ 240V AC Amp 1-Pole 2-Pole 3-Pole Rating 277V 480/277V 480Y/277V BQD115 BQD215 BQD315 15 BQD120 BQD220 BQD320 20 BQD125 BQD225 BQD325 25 BQD130 BQD230 BQD330 30 BQD135 BQD235 BQD335 35 BQD140 BQD240 BQD340 40 BQD145 BQD245 BQD345 45 BQD150 BQD250 BQD350 50 BQD160 BQD260 BQD360 60 BQD170 BQD270 BQD370 70 BQD180 BQD280 BQD380 80 BQD190 BQD290 BQD390 90 BQD1100 BQD2100 BQD3100 100 GB Family Branch Breakers NGB – 25,000A IR Max. @ 480/277V AC /100,000A IR max. @ 240V A HGB – 35,000 A IR Max. @ 480/277V AC / 100,000 A IR @ 240V AC LGB – 65,000 A IR Max. @ 480/277V AC / 100,000 A IR @ 240V AC Amp Rating 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 1-Pole 277V xGB1B015B xGB1B020B xGB1B025B xGB1B030B xGB1B035B xGB1B040B xGB1B045B xGB1B050B xGB1B060B xGB1B070B xGB1B080B xGB1B090B xGB1B100B xGB1B110B xGB1B125B 2-Pole 480/277V xGB2B015B xGB2B020B xGB2B025B xGB2B030B xGB2B035B xGB2B040B xGB2B045B xGB2B050B xGB2B060B xGB2B070B xGB2B080B xGB2B090B xGB2B100B xGB2B110B xGB2B125B 3-Pole 480Y/277V xGB3B015B xGB3B020B xGB3B025B xGB3B030B xGB3B035B xGB3B040B xGB3B045B xGB3B050B xGB3B060B xGB3B070B xGB3B080B xGB3B090B xGB3B100B xGB3B110B xGB3B125B Replace x with N, H or L depending on desired type of breaker Note: 2-pole and 3-pole xGB Frame Breakers are also rated at 14,000 A IR max. for 600Y/347V AC systems. UPB interiors are only rated to 480V max. – see factory assembled section for proper interiors. GFCI Personnel Protection (5MA) Breaker Type BLF 1-Pole BLF 2-Pole BLHF 1-Pole BLHF 2-Pole Ampere Rating 15 20 25 30 15 20 30 40 50 60 15 20 30 15 20 30 40 50 60 Catalog Number BF115 BF120 BF125 n BF130 BF215 BF220 BF230 BF240 n BF250 n BF260 n BF115H BF120H BF130H n BF215H n BF220H n BF230H n BF240H n BF250H n BF260H n Interrupting Ratings (kA) (RMS Symmetrical Amperes) Volts AC 120 120/240 240 — — 10 — — 10 — — 10 — — 10 — 10 — — 10 — — 10 — — 10 — — 10 — — 10 — — — 22 — — 22 — — 22 — 22 — — 22 — — 22 — — 22 — — 22 — — 22 — EQF Equipment Protection (30MA) Breaker Type BLE Ampere Rating 15 1-Pole 20 120V AC 30 BLE 15 2-Pole 20 120/240V AC 30 40 50 60 BLEH 15 1-Pole 20 30 BLEH 15 2-Pole 20 30 40 50 60 Catalog Number BE115 n BE120 BE130 BE215 n BE220 BE230 BE240 n BE250 n BE260 n BE115H n BE120H n BE130H n BE215H n BE220H n BE230H n BE240H n BE250H n BE260H n n Built to order. Allow 2-3 weeks for delivery. Interrupting Ratings (kA) (RMS Symmetrical Amperes) Volts AC 120 120/240 240 — — 10 — — 10 — — 10 — 10 — — 10 — — 10 — — 10 — — 10 — — 10 — — — 22 — — 22 — — 22 — 22 — — 22 — — 22 — — 22 — — 22 — — 22 — AFCI – Combination Type Arc Fault Circuit Interrupter Breaker Type BAF2 1-pole BAFH2 1-pole HBAF2 1-pole BAF 2-pole BAFH 2-pole Ampere Rating 15 20 15 20 15 20 15 20 15 20 Catalog Number B115AFC B120AFC B115AFCH B120AFCH BA115AFCHH BA120AFCHH B215AFC B220AFC B215AFCH B220AFCH Interrupting Ratings (kA) (RMS Symmetrical Amperes) Volts AC 120 10 10 22 22 65 65 10 10 22 22 120/240 — — — — — — — — — — 240 — — — — — — — — — — AFCI – Branch Feeder Type Arc Fault Circuit Interrupter Breaker Type BAF2 1-pole BAF2H 1-pole HBAF2 1-pole Ampere Rating 15 20 15 20 15 20 Catalog Number BA115AF BA120AF BA115AFH BA120AFH BA115AFHH BA120AFHH Interrupting Ratings (kA) (RMS Symmetrical Amperes) Volts AC 120 10 10 22 22 65 65 120/240 240 — — — — — — — — — — — — Switching Neutrals Breaker Type BG Ampere Rating 15 20 30 BG 15 20 30 2-Wire Common Trip 3-Wire Common Trip Catalog Number BG215 n BG220 n BG230 n BG315 n BG320 n BG330 n Maximum Interrupting Ratings (kA) Volts AC 120 120/240 240 10 — — 10 — — 10 — — — — — 10 10 10 — — — n Built to order. Dual Function AFCI/GFCI Circuit Breaker Interrupting Ratings (kA) RMS Symmetrical Amperes Breaker Type BFGA2 1-pole BFGAH2 1-pole HBFGA2 1-pole Ampere Rating 15 20 15 20 15 20 Catalog Number BA115DF BA120DF BA115DFH BA120DFH BA115DFHH BA120DFHH Volts AC 120 120/240 240 10 — — 10 — — 22 — — 22 — — 65 — — 65 — — Catalog Numbering System Unassembled Panelboards P 1 X 1 8 MC 2 5 0 A T 1 2 3,4 5,6 7,8,9 10 11 1. P1 2. Voltage and System X = 208Y/120, 3 Phase, 4 Wire A = 120/240V, 1 Phase, 3 Wire E = 480Y/277V, 3 Phase, 4 Wire 7 = xGB interior, 480Y/277V, 3-Phase 4-Wire 3, 4. Circuit – 18, 30, 42 , 54* (* Revised P1 only) 5, 6. Mains MC = Convertible mains Select Main Lug Kit or Breaker Mounting Kit Select Main Breaker Kit 7, 8, 9. Amperage – 400A Max 10. Main Bus Material A = Tin-plated aluminum C = Copper Temp. Rated 11. SubFeed Space Indicator “T” indicates that a subfeed space is available – Feed-Thru configuration. Factory assembled panels may have an “N” indicating a NFT or Non-Feed-Thru configuration. Type P1 unassembled panelboards are completely convertible from main lug to main breaker and vice-versa. Additionally, feed-thru lugs, or a subfeed circuit breaker up to 400 amperes can be added without increasing the box height. Follow these easy steps to select and price the proper P1 panel from stock: 1. Compute total number of poles to determine interior catalog number. 2. List catalog number and price of interior, box and front. 3. Select main lug kit or main breaker kit from appropriate tables. Note: Main/Subfeed Breaker mounting kits may be ordered with or without breakers included. 4. List required branch circuit breakers and filler plates to cover any unused portions. 5. Select any modifications or accessories. The Original P1 series interiors can be identified as "not having" either a "T" or an "N" at the end of the Panel number. The Revised P1 panels were introduced in January 2015. Revised P1 Panels DO NOT use the same accessories as the Original P1. Breaker Mounting Kits 250A Max. – Main or Subfeed without Breaker Amp rating Breaker type Service 100 BQD 3 Phase 1 Phase 100 BL, BLH, HBL 3 Phase 125 1 Phase NGB, HGB, LGB 3 Phase 1 Phase 125 ED4, ED6, HED4, HED6 3 Phase 1 Phase 225 QJ2, QJH2, QJ2-H 3 Phase 1 Phase 250 FXD6, FD6, HFD6, HFXD6 3 Phase JXD2, JD6, JXD6, 1 Phase 400 1 HJD6, HJXD6 3 Phase 1 2 Catalog number MBKBFA2 MBKBFA2 MBKBFA2 MBKBFA2 MBKBFA2 MBKED1A MBKED3A MBKQJ1A MBKQJ3A MBKFD1A MBKFD3A MBKJD1A MBKJD3A 400 amp kit is for main only – not allowed for subfeed breaker. Back-fed main occupies branch space. Breaker Mounting Kits With Breakers for P1 Panels (250A and lower can be used as subfeed kits also) Rating Catalog Number MBKED3100A MBKED3125A MBKQJ1125A MBKQJ1150A MBKQJ1175A MBKQJ1200A MBKQJ1225A MBKQJ3125A MBKQJ3150A MBKQJ3175A MBKQJ3200A MBKQJ3225A MBKQJ1125HA MBKQJ1150HA MBKQJ1175HA MBKQJ1200HA MBKQJ1225HA MBKQJ3125HA MBKQJ3150HA MBKQJ3175HA MBKQJ3200HA MBKQJ3225HA MBKFD3150A MBKFD3175A MBKFD3200A MBKFD3225A MBKFD3250A MBKJD1300A1 MBKJD3300A1 MBKJD1400A1 MBKJD3400A1 MBKJD12300A1 MBKJD32300A1 MBKJD12400A1 Description Kit w/3 pole ED4 100A breaker Kit w/3 pole ED4 125A breaker Kit w/2 pole QJ2 125A breaker Kit w/2 pole QJ2 150A breaker Kit w/2 pole QJ2 175A breaker Kit w/2 pole QJ2 200A breaker Kit w/2 pole QJ2 225A breaker Kit w/3 pole QJ2 125A breaker Kit w/3 pole QJ2 150A breaker Kit w/3 pole QJ2 175A breaker Kit w/3 pole QJ2 200A breaker Kit w/3 pole QJ2 225A breaker Kit w/2 pole QJ2H 125A breaker Kit w/2 pole QJ2H 150A breaker Kit w/2 pole QJ2H 175A breaker Kit w/2 pole QJ2H 200A breaker Kit w/2 pole QJ2H 225A breaker Kit w/3 pole QJ2H 125A breaker Kit w/3 pole QJ2H 150A breaker Kit w/3 pole QJ2H 175A breaker Kit w/3 pole QJ2H 200A breaker Kit w/3 pole QJ2H 225A breaker Kit w/3 pole FXD6 150A breaker Kit w/3 pole FXD6 175A breaker Kit w/3 pole FXD6 200A breaker Kit w/3 pole FXD6 225A breaker Kit w/3 pole FXD6 250A breaker Kit w/2 pole JXD6 300A breaker Kit w/3 pole JXD6 300A breaker Kit w/2 pole JXD6 400A breaker Kit w/3 pole JXD6 400A breaker Kit w/2 pole JXD6 300A breaker Kit w/3 pole JXD6 300A breaker Kit w/2 pole JXD6 400A breaker 240V 65kA 65kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 42kA 42kA 42kA 42kA 42kA 42kA 42kA 42kA 42kA 42kA 65kA 65kA 65kA 65kA 65kA 65kA 65kA 65kA 65kA 65kA 65kA 65kA 480V 18kA 18kA — — — — — — — — — — — — — — — — — — — — 35kA 35kA 35kA 35kA 35kA 35kA 35kA 35kA 35kA — — — MBKJD32400A1 Kit w/3 pole JXD6 400A breaker 65kA — 1 Kits can be used for either top feed or bottom feed. Lug Kits — Main or Feed Thru Amp Rating 250 400 400 Matl. AL CU AL CU AL Wire Range (includes Neutral) (1) #6 AWG350 kcmil (CU or AL) (1) #6 AWG350 kcmil (CU or AL) (2) 1/0 - 250 kcmil or (1) #2 AWG-600 kcmil (2) 1/0 - 4/0 or (1) 1/0 - 600 kcmil AL 1/0-750 kcmil (max. 600 kcmil CU wire) Service 1 Phase 3 Phase 1 Phase 3 Phase 1 Phase 3 Phase 1 Phase 3 Phase 1 Phase 3 Phase Copper Neutral Lug Kits — 250A Number of Circuits Description 18 30 42 54, 66 2 or 4 Branch Neutral Strips, 1 Main Neutral Lug, Hardware 2/0 Neutral Lug Kits — 250A and 400A 18 30 42 54, 66 2 or 4 Branch Neutral Strips, Hardware 200% Neutral Lug Kits/250A 18 30 42 54, 66 2 or 4 Branch Neutral Strips, 1 Main Neutral Lug, Hardware 200% Neutral Lug Kits/400A 18 30 42 54, 66 2 or 4 Branch Neutral Strips, 1 Main 600MCM Neutral Lug, Hardware Catalog Number MLKA1A MLKA3A MLKC1A MLKC3A 4MLKA1A 4MLKA3A 4MLKC1A 4MLKC3A 4MLKA1B 4MLKA3B Revised P1 Catalog Number Use 30 ckt kit CNKL30A CNKL42A CNLK54A Use 30 ckt kit LNLK30A LNLK42A LNLK54A Use 30 ckt kit 2NK30A 2NK42A 2NK54A Use 30 ckt kit 42NLK30A 42NLK42A 42NLK54A Type P1, P2, P3, SE and S3 Panelboards Miscellaneous Parts and Accessories Catalog # BK1 BK1A BK2 BK3 P2BK1 P2BK2 P2BK3 P3BK1 IMK1 11-1824-01 12-1110-01 11-1056-01 Description Bonding Kit for 400A max. Original P1 panels Bonding Kit for 400A max. Revised P1 Panels Bonding Kit for S1/S2 400 and 600 Bonding kit for S3 Bonding Kit for P2 250A Max. Bonding Kit for P2 400A Max. Bonding Kit for P2 600A Max. Bonding kit for P3 Interior Adjusting Kit Directory Card Holder Directory Card NEMA Instruction Book Number Strips 1–42 , Stick-on type: NBK03 Use w/P1 series Panels Number Strips 43–84, Stick-on type: NBK04 Use w/P1 series Panels Number Strips 85–126, Stick-on type: NBK05 Use w/P1 series Panels Number Strips 127–168, Stick-on type: NBK06 Use w/P1 series Panels EGK AL Ground Bus 44 Connections ECGK CU Ground Bus 44 Connections IGK Insulated AL Ground Bus ICGK Insulated CU Ground Bus EWK1 End Wall Kit with Knockouts (20" W x 5.75" DP) EWK2 End Wall Kit with Knockouts (24" W x 7.75" DP) EBF1 NEB/HEB Filler Plate P1SCRWS Package of 42 breaker mounting screws for P1 1" Branch circuit filler plate (suitable for replacing DFFP1 QF3 in P1 thru P5 Panelboards and Switchboards) 1 Connector kit – 6 pcs. B-phase Copper P1CONBPHCU 1 kit – 6 pcs. B-phase Aluminum 1P1CONBPHAL Replacement parts Connector only. P1CONACPHCU 1 Connector kit – 6 pcs. A or C-phase Copper P1CONACPHAL 1 Connector kit – 6 pcs. A or C-phase Aluminum 1 Replacement Parts Only. 400/600A S1/S2 and All SE Panels Amp Breaker Type Rating 125 ED2, ED4, ED6, HED4, HED6, HHED6 225 ED2, ED4, ED6, HED4, HED6, HHED6 QJ2, HQJ2, HQJ2H 225 QJ2, HQJ2, HQJ2H FXD6, FD6, HFXD6, HFD6 250 FXD6, FD6, HFXD6, HFD6 JD6, JXD6, HJD6, HJXD6 400 JD6, JXD6, HJD6, HJXD6 LD6, LXD6, HLD6, HLXD6 600 LD6, LXD6, HLD6, HLXD6 Service 1 Phase 3 Phase 1 Phase 3 Phase 1 Phase 3 Phase 1 Phase 3 Phase 1 Phase 3 Phase Catalog Number SMBKED1 SMBKED3 SMBKQJ1 SMBKQJ3 SMBKFD1 SMBKFD3 SMBKJD1 SMBKJD3 SMBKLD1 SMBKLD3 SPP/FPP/S4/S5/P4/P5/F1/F2 Kits Category 1 10” Deep S4/P4/SPP FPP/P1 SBL SE6 SCE SQJ SF6 SCF SJ1 — SSJ1 SCJ SSCJ SL6 SSL6 SCL SSCL SLM1 Category 2 12.75” Deep S5/P5/F2 SPP/FPP SBLBD SE6D SCED SQJD SF6D SCFD SJ1D SJ2D SSJ1D SCJD SSCJD SL6D SSL6D SCLD SSCLD SLM1D Breaker Type BL/BQD ED CED6 QJ FD6 CFD6 JXD2, JXD6 JXD2, JXD6 SJD6 CJD6 SCJD6 LD6 SLD6 CLD6 SCLD6 LMD6, HLMD6 MD6, HMD6, CMD6 SMD6, SHMD6 ND6, HND6 SND6, SHND6 SCND6 Mounting Twin Twin Single Twin Twin Single Single Twin Single Single Single Single Single Single Single Single Unit Height Inches 3.75 3.75 3.75 5.00 5.00 5.00 8.75 8.75 8.75 8.75 8.75 8.75 8.75 8.75 8.75 8.75 Single 10 — SMND Single Single 10 10 — — SSMND SMND Single 10 — SSMND MG1D Single 10 — NG1D Single 10 — NM, HM, LM, SNM, SHM NN, HN, LN, SNN, SHN P2/P3 Kits and Accessories Kit Number BBKB32 BBKED32 BBKNB32 BBKQ1 BBKQ2 DKF1 DFFP3 DFFP6 BNK2 P2BK1 P2BK2 P2BK3 P3BK1 Description BL/BQD 6-pole 3” branch breaker kit ED 6-pole 3” branch breaker kit xGB branch mounting kit (NGB, HGB & LGB) QJ branch breaker kit for 2 and 3-pole single mount Branch breaker kit for 2 and 3-pole QJ twin mount (P3) BL, BQD, ED deadfront kit for 1” pole breakers Deadfront filler 3” Deadfront filler 6” Branch Neutral (P2) P2 250A max. bonding kit P2 400A max. bonding kit P2 600A max. bonding kit P3 bonding kit Internal TPS All internal TPS standard monitoring includes LED Indicators TPS3 01, L1, 05, L5, 06, L6 standard monitoring includes: - LED indicators - Audible Alarm with Silence and Test Buttons - Dry Contacts TPS3 02 is for new Revised P1 only – not for use in Original P1. TPS3 01 Surge Protection Device (SPD) for Original P1, P2 Lighting Panelboards and P3 Power Distribution Panelboards, Motor Control Centers and Busway Systems Mounts internal to: - P1, P2 and P3 panels - tiastar motor control centers – standard 6” bucket - STP series busplug on SX series busway Ordering Information – When an option is not selected, put a zero (0) in the field. T P S 3 0 1 1 2 3X 3W 3BorM 3. Options 1. Voltage Code 2. Surge X = Surge A = 120/240V, 1Ø, 3W Current (kA) counter B = 120/240V, 3Ø, 4W 10 = 100kA per phase C = 120/208V, 3Ø, 4W 15 = 150kA per phase W = Terminal lug D = 240V, 3Ø, 3W 20 = 200kA per phase B = Busway application E = 277/480V, 3Ø, 4W 25 = 250kA per phase F = 480V, 3Ø, 3W 30 = 300kA per phase M = MCC application G = 600V, 3Ø, 3W K = 380/220V, 3Ø, 4W L = 600/347V, 3Ø, 4W S = 400/230V, 3Ø, 4W Available accessories ordered separately. RMSIE – remote monitor. Example: TPS3C0120X00 = SPD for a 208/120V panelboard with a surge capacity of 200kA per phase and a surge counter option. TPS3 L2 is for new Revised P1 only – not for use in Original P1. TPS3 L1 True 10 Mode Protection, Surge Protection Device (SPD) for Original P1, P2 Lighting and P3 Power Distribution Panelboards, Motor Control Centers and Busway Systems Mounts internal to: • P1, P2 and P3 panels • tiastar motor control centers – standard 6” bucket • STP series busplug on SX series busway Ordering Information – When an option is not selected, put a zero (0) in the field T P S 3 L 1 1 2 3X 3W 3BorM 1. Voltage Code 2. Surge 3. Options A = 120/240V, 1Ø, 3W Current (kA) X = Surge counter B = 120/240V, 3Ø, 4W 15 = 150kA per phase W = Terminal lug C = 120/208V, 3Ø, 4W 30 = 300kA per phase B = Busway E = 277/480V, 3Ø, 4W application K = 380/220V, 3Ø, 4W M = MCC S = 400/230V, 3Ø, 4W application Available accessories ordered separately. RMSIE – remote monitor. Example: TPS3CL130X00 = 10 Mode SPD for a 208/120V panelboard with a surge current capacity of 300kA per phase and a surge counter option. TPS3 05 Surge Protection Device (SPD) for P4 and P5 Panelboards and Distribution Switchboards Mounts internal to: - P4 and P5 panelboards and distribution switchboards Ordering Information – When an option is not selected, put a zero (0) in the field. T P S 3 0 5 1 1. Voltage Code A = 120/240V, 1Ø, 3W B = 240/120V, 3Ø, 4W C = 120/208V, 3Ø, 4W D = 240V, 3Ø, 3W E = 277/480V, 3Ø, 4W F = 480V, 3Ø, 3W G = 600V, 3Ø, 3W 1 K = 380/220V, 3Ø, 4W L = 600/347V, 3Ø, 4W S = 400/230V, 3Ø, 4W 1 Available 2 2. Surge Current (kA) 10 = 100kA per phase 15 = 150kA per phase 20 = 200kA per phase 25 = 250kA per phase 30 = 300kA per phase 3 3. Options X = Surge counter in 100 and 150 kA only. Available accessories ordered separately. RMSIE – remote monitor. Example: TPS3C0530X = SPD for a 208/120V power panel with a surge current capacity of 300kA per phase and a surge counter option. TPS3 L5 True 10 Mode Protection Surge Protection Device (SPD) for P4 and P5 Panelboards and Distribution Switchboards Mounts internal to: • P4 and P5 panelboards and distribution switchboards Ordering Information – When an option is not selected, put a zero (0) in the field. T P S 3 L 5 1 1. Voltage Code A = 120/240V, 1Ø, 3W B = 120/240V, 3Ø, 4W C = 120/208V, 3Ø, 4W E = 277/480V, 3Ø, 4W K = 380/220V, 3Ø, 4W S = 400/230V, 3Ø, 4W 2 2. Surge Current (kA) 15 = 150kA per phase 30 = 300kA per phase 3 3. Options X = Surge counter Available accessories ordered separately. RMSIE Available accessories ordered separately. RMSIE – remote monitor. Example: TPS3CL530X = 10 mode SPD for a 208/120V power panel with a surge current capacity of 300kA per phase and a surge counter option. TPS3 06 Surge Protection Device (SPD) for Service Entrance Applications – SB1, SB2, SB3, Type RCS Switchboards, Type WL Low Voltage Switchgear, Motor Control Centers and Busway Systems Mounts internal to: - SB1, SB2, SB3 and Type RCS switchboards - Type WL low voltage switchgear - tiastar motor control centers - standard 12” bucket - STP series busplug on SX series busway Ordering Information – When an option is not selected, put a zero (0) in the field. T P S 3 0 6 1 1. Voltage Code A = 120/240V, 1Ø, 3W B = 120/240V, 3Ø, 4W C = 120/208V, 3Ø, 4W D = 240V, 3Ø, 3W 1 E = 277/480V, 3Ø, 4W F = 480V, 3Ø, 3W 1 G = 600V, 3Ø, 3W 2 K = 380/220V, 3Ø, 4W L = 600/347V, 3Ø, 4W S = 400/230V, 3Ø, 4W 2 3X 2. Surge Current (kA) 10 = 100kA per phase 15 = 150kA per phase 20 = 200kA per phase 25 = 250kA per phase 30 = 300kA per phase 40 = 400kA per phase 50 = 500kA per phase 3W 3BorM 3. Options X = Surge counter B = Busway application 3 M = MCC application 3 1 Not available in 500 kA. 2 Available in 150, 200, 250 kA only 3 G voltage code only available in 200 and 250 kA. Available accessories ordered separately. RMSIE – remote monitor. Example: TPS3C0640X0 = SPD for a 208/120V switchboard with a surge current capacity of 400kA per phase and a surge counter option. TPS3 L6 True 10 Mode Protection Surge Protection Device (SPD) for Service Entrance Applications – SB1, SB2, SB3, Type RCS Switchboards, Type WL Low Voltage Switchgear, Motor Control Centers and Busway Systems Mounts internal to: SB1, SB2, SB3 and Type RCS switchboards - Type WL low voltage switchgear - tiastar motor control centers - standard 12” bucket - STP series busplug on SX series busway Ordering Information – When an option is not selected, put a zero (0) in the field. T P S 3 L 6 1 2 1. Voltage Code 2. Surge Current (kA) A = 120/240V, 1Ø, 3W 15 = 150kA per phase B = 120/240V, 3Ø, 4W 30 = 300kA per phase C = 120/208V, 3Ø, 4W E = 277/480V, 3Ø, 4W K = 380/220V, 3Ø, 4W S = 400/230V, 3Ø, 4W 3X 3W 3BorM 3. Options X = Surge counter B = Busway application M = MCC application Available accessories ordered separately. RMSIE – remote monitor. Example: TPS3CL645X0 = 10 mode SPD for a 208/120V switchboard with a surge current capacity of 450kA per phase and a surge counter option. External or Wall Mount TPS All external TPS standard monitoring includes LED indicators TPS3 03, 09 and 11 standard monitoring include: - LED Indicators TPS3 12, and L12 standard monitoring include: - LED Indicators - Audible Alarm with Silence and Test Buttons - Dry Contacts TPS3 15, and L15 standard monitoring include: - LED Indicators - Audible Alarm with Silence and Test Buttons - Dry Contacts - Disconnect Switch TPS3 03 Type 1 Surge Protective Device (SPD) TPS3 03 Mounts external to electrical distribution equipment - Recommended for line side or load side applications Ordering Information – When an option is not selected, put a zero (0) in the field. T P S 3 0 3 1 1. Voltage Code A = 120/240V, 1Ø, 3W B == 120/240V, 3Ø, 4W C == 120/208V, 3Ø, 4W D = 240V, 3Ø, 3W E == 277/480V, 3Ø, 4W F == 480V, 3Ø, 3W G = 600V, 3Ø, 3W K == 380/220V, 3Ø, 4W L == 600/347V, 3Ø, 4W 2. Surge Current (kA) 05 = 50kA per phase 2 3 3. Options D = Dry contact and audible alarm Available accessories ordered separately. RMSIE – remote monitor. Example: TPS3C0305D = Type 1 SPD for a 208/120V application with a surge current capacity of 50kA per phase, in a standard NEMA 4X enclosure with dry contacts and audible alarm option. TPS3 09 Type 1 Surge Protective Device (SPD) Internal to P1, P2 Lighting Panelboards, P3 Power Panelboards and Busway Systems Mounts external to electrical distribution equipment - Weatherproof hub included - Recommended for line side or load side applications Mounts internal to P1 panelboards and busway - P1 – Field retrofit or factory install - P2 and P3 – Factory install only *Consult factory for field retrofit Ordering Information – When an option is not selected, put a zero (0) in the field. T P S 3 0 9 1 1. Voltage Code A = 120/240V, 1Ø,3W B = 120/240V, 3Ø, 4W C = 120/208V, 3Ø, 4W D = 240V, 3Ø, 3W E = 277/480V, 3Ø, 4W F = 480V, 3Ø, 3W G= 600V, 3Ø, 3W K = 380/220V, 3Ø, 4W L = 600/347V, 3Ø, 4W S = 400/230V, 3Ø, 4W 2 2. Surge Current (kA) 10 = 100kA per phase 3D 3I 3E 3. Options D = Dry contact and audible alarm I = Internal mounting in P1, P2 panels 1 E = Extended indicator light Available accessories ordered separately. RMSIE – remote monitor. FMKITC – Flush mount kit TPS9IKITP1 – Mounting bracket for installation in P1 panels 1 Requires TPS9IKITP1 mounting bracket accessory. Example: TPS3C0910D00 = Type 1 SPD for a 208/120V panelboard with a surge current capacity of 100kA per phase with standard NEMA 4X enclosure, dry contacts and audible alarm option. TPS3 11 – Type 1 Surge Protection Device (SPD) Mounts external to electrical distribution equipment - Recommended for line side or load side applications Ordering Information – When an option is not selected, put a zero (0) in the field. T P S 3 1 1 1 2 3 2. Surge Current (kA) 3. Options 1. Voltage Code D = Dry contact 10 = 100kA per phase A== 120/240V, 1Ø, 3W and audible 15 = 150kA per phase B== 120/240V, 3Ø, 4W alarm 20 = 200kA per phase C == 120/208V, 3Ø, 4W D== 240V, 3Ø, 3W E == 277/480V, 3Ø, 4W F == 480V, 3Ø, 3W G = 600V, 3Ø, 3W 1 K == 380/220V, 3Ø, 4W L == 600/347V, 3Ø, 4W S == 400/230V, 3Ø, 4W Available accessories ordered separately. RMSIE – Remote monitor KITFMXF – Flush mount kit 1 Available in 100kA per phase only. Example: TPS3C1110D = Type 1 SPD for a 208/120V application with a surge current capacity of 100kA per phase, in a standard NEMA 4X enclosure with dry contacts and audible alarm option. TPS3 12 Type 1 Surge Protective Device (SPD) Mounts external to electrical distribution equipment - Recommended for line side or load side applications Ordering Information – When an option is not selected, put a zero (0) in the field. T P S 3 1 2 1 1. Voltage Code A = 120/240V, 1Ø, 3W B = 120/240V, 3Ø, 4W C = 120/208V, 3Ø, 4W D = 240V, 3Ø, 3W 1 E = 277/480V, 3Ø, 4W F = 480V, 3Ø, 3W 1 G = 600V, 3Ø, 3W 2 K = 380/220V, 3Ø, 4W L = 600/347V, 3Ø, 4W S = 400/230V, 3Ø, 4W 2 3 4X 4DorT 2. Surge 3. Enclosure 4. Options X = Surge Current (kA) 0 = Standard counter 10 = 100kA NEMA D = Internal per phase 1/12/3R/4 rotary 15 = 150kA steel per phase V = NEMA 4X disconnect 20 = 200kA non-metallic T = Thru-door per phase S = NEMA 4X disconnect 25 = 250kA stainless steel per phase F = NEMA 1 flush 30 = 300kA mount per phase P = NEMA 1 40 = 400kA screwcover per phase pullbox with 50 = 500kA extended display per phase on 6 ft cable for line side mounting in SWBD/SWGR Available accessories ordered separately. RMSIE – Remote monitor 1 2 Not available in 500kA. Available in 100, 150, 200, 250 kA only. Example: TPS3C12100XD = Type 1 SPD for a 208/120V application with a surge current capacity of 100kA per phase, in a standard NEMA 1/12/3R/4 enclosure with a surge counter and internal rotary disconnect option. TPS3 L12 True 10 Mode Protection Type 1 Surge Protective Device (SPD) Mounts external to electrical distribution equipment - Recommended for line side or load side applications Ordering Information – When an option is not selected, put a zero (0) in the field. T P S 3 L 1 1. Voltage Code A = 120/240V, 1Ø, 3W B = 120/240V, 3Ø, 4W C = 120/208V, 3Ø, 4W E = 277/480V, 3Ø, 4W K = 380/220V, 3Ø, 4W S = 400/230V, 3Ø, 4W 1 2 2 3 4X 4DorT 2. Surge 3. Enclosure 4. Options X = Surge Current (kA) 0 = Standard counter 15 = 150kA NEMA D = Internal per phase 1/12/3R/4 rotary 30 = 300kA steel per phase V = NEMA 4X disconnect 45 = 450kA non-metallic T = Thru-door per phase S = NEMA 4X disconnect stainless steel F = NEMA 1 flush mount P = NEMA 1 screwcover pullbox with extended display on 6 ft cable for line side mounting in SWBD/SWGR Available accessories ordered separately. RMSIE – Remote monitor Example: TPS3CL12150XD = 10 Mode, Type 1 SPD for a 208/120V application with a surge current capacity of 150kA per phase, in a standard NEMA 1/12/3R/4 enclosure with a surge counter and internal rotary disconnect option. TPS3 15 Type 1 Surge Protective Device (SPD) Mounts external to electrical distribution equipment - Recommended for line side or load side applications Ordering Information – When an option is not selected, put a zero (0) in the field. T P S 3 1 5 1 1. Voltage Code A = 120/240V, 1Ø, 3W B = 120/240V, 3Ø, 4W C = 120/208V, 3Ø, 4W D = 240V, 3Ø, 3W 1 E = 277/480V, 3Ø, 4W F = 480V, 3Ø, 3W 1 G = 600V, 3Ø, 3 W 2 K = 380/220V, 3Ø, 4W L = 600/347V, 3Ø, 4W S = 400/230V, 3Ø, 4W 2 3 4X 4T 2. Surge 3. Enclosure 4. Options X = Surge Current (kA) 0 = Standard counter 40 = 400kA NEMA per phase 3 1/12/3R/4 T = Thru-door disconnect 50 = 500kA steel per phase 3 V = NEMA 4X 60 = 600kA non-metallic per phase S = NEMA 4X 80 = 800kA stainless steel per phase F = NEMA 1 flush 1K = 1000kA mount per phase P = NEMA 1 screwcover pullbox with extended display on 6 ft cable for line side mounting in SWBD/SWGR Available accessories ordered separately. RMSIE – Remote monitor Note: Internal disconnect switch is standard. 1 Available in 600 and 800 kA only. 2 Available in 400 and 500 kA only. 3 Available in G voltage code only. Example: TPS3C1560SX0 = Type 1 SPD for a 208/120V application with a surge current capacity of 600kA per phase, in a NEMA 4X stainless steel enclosure with a surge counter option and standard disconnect switch. TPS3 L15 True 10 Mode Protection Type 1 Surge Protective Device (SPD) Mounts external to electrical distribution equipment - Recommended for line side or load side applications Ordering Information – When an option is not selected, put a zero (0) in the field. T P S 3 L 1 5 1 2 3 4X 4T 1. Voltage Code 2. Surge 3. Enclosure 4. Options X = Surge A = 120/240V, Current (kA) 0 = Standard counter 1Ø, 3W 60 = 600kA NEMA T = Thru-door B = 120/240V, per phase 1/12/3R/4 disconnect 3Ø, 4W 90 = 900kA steel C = 208Y/120V per phase V = NEMA 4X 3Ø, 4W non-metallic E = 277/480V, S = NEMA 4X 3Ø, 4W stainless steel K = 380V/220V, F = NEMA 1 flush 3Ø, 4W mount S = 400Y/230V, P = NEMA 1 4W screwcover pullbox with extended display on 6 ft cable for line side mounting in SWBD/SWGR Note: Internal disconnect switch is standard. Example: TPS3CL15600X0 = 10 Mode, Type 1 SPD for a 208/120V application with a surge current capacity of 600kA per phase, in a standard NEMA 1/12/3R/4 enclosure with a surge counter option and standard disconnect switch. General Purpose Transformers Standard Units 1P 480 x 240V Primary, 120/240V Secondary KVA Catalog Number 1D1N205 .25 1D1N505 .50 1D1N705 .75 1D1N001 1.0 1D1N105 1.5 1D1N002 2.0 1D1N003 3.0 1D1N005 5.0 1D1N007 7.5 1D1N010 10 1D1N015 15 1D1Y015TP1 15 1D1Y025TP1 25 1D1Y037TP1 37.5 1D1Y050TP1 50 1D1Y075TP1 75 1D1Y100TP1 100 1D1Y167TP1 167 3P 480 Primary, 208/120V Secondary KVA Catalog Number 3FR003 3 3FR006 6 3FR009 9 3F3Y015TP1 15 3F3Y030TP1 30 3F3Y045TP1 45 3F3Y075TP1 75 3F3Y112TP1 112.5 3F3Y150TP1 150 3F3Y225TP1 225 3F3Y300TP1 300 3F3Y500TP1 500 3P 480 Primary, 240V Secondary with 120V TAP on B Phase KVA 15 30 45 75 112.5 150 225 300 500 Catalog Number 3F1Y015TP1 3F1Y030TP1 3F1Y045TP1 3F1Y075TP1 3F1Y112TP1 3F1Y150TP1 3F1Y225TP1 3F1Y300TP1 3F1Y500TP1 Modified Units 3P 480V Primary, 208Y/120V Secondary Low Temperature 115C Rise KVA 15 30 45 75 112.5 150 225 Catalog Number 3F3Y015FTP1 3F3Y030FTP1 3F3Y045FTP1 3F3Y075FTP1 3F3Y112FTP1 3F3Y150FTP1 3F3Y225FTP1 3P 480V Primary, 208Y/120V Secondary Low Temperature 80C Rise KVA 15 30 45 75 112.5 150 225 Catalog Number 3F3Y015BTP1 3F3Y030BTP1 3F3Y045BTP1 3F3Y075BTP1 3F3Y112BTP1 3F3Y150BTP1 3F3Y225BTP1 3P 480V Primary, 208Y/120V Secondary Noise Attenuation w/ Electrostatic Shield KVA 15 30 45 75 112.5 150 Catalog Number 3F3Y015ESTP1 3F3Y030ESTP1 3F3Y045ESTP1 3F3Y075ESTP1 3F3Y112ESTP1 3F3Y150ESTP1 3P 480V Primary, 208Y/120V Secondary K13 (100% Non-Linear Load) KVA 15 30 45 75 112.5 150 Catalog Number 3F3Y015K13TP1 3F3Y030K13TP1 3F3Y045K13TP1 3F3Y075K13TP1 3F3Y112K13TP1 3F3Y150K13TP1 Catalog Number Coding System for Transformers 3 F 3 Y 150 K13 F ES C LN3 Z4 TE TEE TP1 LZ HM1 NP 30 TS7 TV TB SS SSN4X 13 CC W VG DS BA 1234 5 6 7 8 9 10 11 12 13 14 15 16 Basic Rating Information 1. Phase 2. Primary Voltage 3. Secondary Voltage 4. Taps 5. kVA Optional Modifications 6. K-Factor (K4, K13, K20, K30) 7. Low Temperature Rise: 130C = (G), 115C = (F) 80C = (B) 8. Electrostatic Shield 1 (ES)(ES2=dual) ES3=120dB attenuation on HM1& 2 9. Copper Wound (C) 10. Low Noise X (where X = dB below NEMA, ex LN3 - 3dB below) 11. Seismic Zone 4 Rated (Z4) 12. Totally Enclosed NEMA 3R OR 4 (TE) 13. Totally Enclosed Encapsulated NEMA 3R or 4 (TEE) 14. Energy Efficient (NEMA - TP1) 15. Frequency 50/60Hz 16. Harmonic Mitigation (HM1=1 secondary/single output, HM2=2 secondaries/double output) 17. Super Energy Efficient - Surpasses NEMA-TP1 (available on TP1, HM1, HM2, “TP1NP,” “HM1NP,” “HM2NP 17 18 19 20 21 22 23 24 25 26 27 28 29 18. Phase shift for HM1 select > (00) or (30) degree. Phase shift for HM2 select > (03) for 0 & 30 for 15 & 45 degree lagging, or (PN15) for 15 pos & 15 neg 19. Thermal Switches (TS7=170C,TS8= 180C or TS0=200C) (TS72=2 switches, TS76=6 switches @170C, etc.) 20. TVSS - Filter Capacitors Secondary Side with Surge Suppression 21. Terminal Block 22. Stainless Steel Enclosure N-3R w/DS 23. Enclosure Types NEMA 4X (SSN4X), NEMA 12 (N12), NEMA 4 (N4) 24. Special Impedance – 14 = 4% max, 13 = 3% max etc. 25. Core and Coil Assembly with nameplate displayed on frame bracket (may be shipped in std. enclosure) 26. Wall Mounting Brackets (W) 27. Vent Guard 28. Drip Shields (weathershields) to provide NEMA-3R (DS) 29. Buy America Note 1: If the catalog number will not completely describe the product, it will be identified as SPC- _ _ _KVA-XFMR. Note 2: “JST” suffix on catalog numbers defines units available in some of our distributor stock locations, may be available for immediate shipment – check for availability. Note 3: TP1 alone has K1 load rating. K4 or higher K-Factor options with TP1 indicates associated load profile. Electrostatic Shield and 200% neutral are standard with K4 and above options. Suffix K13TP1 will indicate K-Factor rating and TP1 rating at K1 loading. Note 4: Most transformers come standard with seismic rating. Contact factory for additional information. Note 5: Primary and secondary terminal lugs are included on certain ventilated transformers. (15KVA - 75KVA 3PH & 15KVA - 50KVA 1PH) Optional Product Offerings 1. For non-standard or non-cataloged voltages or non-cataloged primary taps refer to sales office. 2. Non-standard application, 50/60 Hz, special impedance, voltage, etc. – consult sales office. 3. Wall mounting brackets and weathershields – available at no charge on all indicated units when requested at time of initial project order. Contact sales office for feasibility of wall brackets on units with special temperature rise, low noise, or copper windings. 4. Special temperature rise: - 115° C rise, can tolerate 15% continuous overload. (Suffix Code F) 1 - 80° C rise, can tolerate 30% continuous overload. (Suffix Code B)1 5. Copper windings – Available on most designs. (Suffix Code C). 6. Low Noise Suffix code LN3 (3dB below std.) available as indicated. For LN5, etc. contact sales office with required sound level. 7. Totally Enclosed Non-Ventilated (TE) 8. Auto transformers (A) 9. Non-standard paint color – contact sales office. 10. Electrostatic shield (full width copper foil) for added noise attenuation and reduction of high frequency disturbances. (Suffix Code ES) 2 11. Super Energy Efficient (NEMA Premium ) – Exceeds NEMA TP1 efficiencies by 30%. 12. Harmonic mitigating transformers 13. Transformer and panel combinations 1 With continuous overloads these units will be operating as 150°C rise designs. 2 ”XES” Suffix coding for shielded isolation with filters and surge suppression. Optional Product Offerings Phase Primary 240x120 208 240 480x240 277 480 600 190/200/208/220/x380 400/416/440 190/208/220/240x380 416/440/480 1-Phase 1 3-Phase 3 TAP Designations Description None 2-5% FCBN 2–5% (1 FCAN, 1 FCBN) 2–2.5% FCBN 6–2.5% (2 FCAN, 4 FCBN) A B C D E F G Export Range H Export Range X Secondary 120/240 240 1 208Y/120 120/208 1 480Y/277 380Y/219 230Y/133 110/220 1 2 3 3 5 6 7 8 Designation N R S U Y KVA KVA 0.25 0.50 0.75 1 1.5 2 3 Catalog Code 205 505 705 001 105 002 003 KVA 5 6 7.5 9 10 15 25 Catalog Code 005 006 007 009 010 015 025 KVA 30 37.5 45 50 75 100 112.5 1 Available in 3-phase 3 to 15 KVA only. 2 Applies to HMT designs. 3 Taps are determined by transformer design Catalog Code 030 037 045 050 075 100 112 KVA 150 167 225 300 500 750 1000 Catalog Code 150 167 225 300 500 750 1000 and are not selectable on standard catalog units. Terminal Lug Kits For Ventilated Transformers Catalog Number TLK34Q TLK14Q Single Phase KVA Sizes — 100 Three Phase KVA Sizes 112.5 — Terminal Lug 1 Qty . 11 12 Cable Lug No. Range AB-350S 6awg-350mcm AB-350S 6awg-350mcm Terminal Lug Kits For Ventilated Transformers (cont’d) Catalog Number TLK34Q TLK14Q 1 Terminal Terminal Lug 1 Qty. Lug No. n/a n/a — — Cable Range — — Hardware Included Qty. Bolt Size 11 12 3/8” x 1 1/2” 3/8” x 1 1/2” lugs are screw type, lug connectors suitable for both copper and aluminum cable. Each barrel is suitable for cable range shown. Lugs are rated 90ºC. General Duty Enclosed Switches Features: n Compact size n Horsepower rated n Indoor and Outdoor Enclosure n Quick Make, Quick Break Mechanism n Visible “ON” and “OFF” indications n Padlock-Off Handle Feature n Door Padlock Provision n Bondable Interior (where indicated) n Lugs Suitable for Copper and Aluminum Wires n UL Listed n Provisions for T, R, S, H and K Class Fuses (T&J 100-600A) NEW-SPP Pocket Refer Guide :PBBR-REFGD-0510 7/26/10 4:57 PM Page 40 NEW-SPP NEW-SPP Pocket Pocket Refer Refer Guide Guide :PBBR-REFGD-0510 :PBBR-REFGD-0510 7/26/10 7/26/10 4:57 4:57 PM PM Page Page 40 40 General Duty Enclosed Switches General Duty Safety Switches 240V FusibleGeneral General Duty Duty Safety Safety Switches Switches 2P, 2F, and Neutral 1 2 3 240V AC / 250V DC 240V Fusible 240V Fusible 1 2 3 240V AC / 250V DC 2P, 2F, and Neutral Indoor Outdoor 240V Fusible 240V AC / 250V DC 2P, 2F, and Neutral 11 22 33 Type 1 Indoor 240V Type AC3R / 250V DC 2P, 2F, and Neutral Outdoor Ampere Catalog Catalog Indoor Outdoor Type 1 Type 3R Indoor Outdoor System RatingAmpereNumber Number Type 1 Type 3R Catalog Catalog Type 1 Type 3R Catalog Catalog 30 Ampere System Rating GF221N Number GF221NR Number Ampere Catalog Catalog System Rating Number Number 30 GF221N GF221NR System Number Number 60 Rating GF222N GF222NR 30 GF221N GF221NR 60 GF222N GF222NR GF221N GF221NR 100 30 GF223N GF223NR 60 GF222N GF222NR 100 GF223N GF223NR 60 GF222N GF222NR 200 100 GF224NR GF223N GF223NR 200 GF224N GF224N GF224NR 100 GF223N GF223NR GF224N GF224NR 4 4 4 4 GF225NRH 400 200 400 GF225NH GF225NH GF225NRH 200 GF224N GF224NR 4 4 GF225NH GF225NRH 400 GF225N 4 GF225NR GF225NR 4 400 400 GF225N 400 GF225NH GF225NRH 400 GF225N GF225NR 4 4 600 GF226NH GF226NRH 400 GF225N GF225NR 4 4 600 600 GF226NH 4 GF226NRH 4 GF226NH GF226NRH 600 GF226N 4 GF226NR 4 600 GF226NH GF226NRH 600 600 GF226N GF226NR GF226N GF226NR 600 GF226N GF226NR 3 3P, 3F and Neutral 240V AC / 250V DC 3 240V AC / 250V DC 3P, 3F, and Neutral 240V AC / 250V DC 3P, 3F, and Neutral 33 Indoor Outdoor 240VOutdoor AC / 250V DC 3P, 3F, and Neutral Type 1 Indoor Type 3R Indoor Outdoor Type 1 Type 3R Indoor Outdoor Ampere Catalog Catalog Type 1 Type 3R Catalog Catalog Type 1 Type 3R System RatingAmpereNumber Number Ampere Catalog Catalog Number Number System Rating Ampere Catalog Catalog 30 Rating GF321N GF321NR Number Number System 30 GF321N GF321NR Number Number System Rating 30 GF321N GF321NR 60 GF322 GF321N GF322NR 60 GF322N GF322NR 30 GF321NR 60 GF322N GF322NR GF323N GF323NR 60 GF322N GF322NR 100 100 GF323N GF323NR 100 GF323N GF323NR 200 GF324N GF324NR GF323N GF323NR 200 100 GF324N GF324NR 200 GF324N 400 GF325NH 4 GF324NR GF325NRH 4 200 GF324N GF324NR 4 4 4 GF325NH GF325NRH 400 400 GF325NH 4 GF325NRH 400 GF325N GF325NR4 4 400 GF325NH GF325NRH 400 GF325N GF325NR 600 GF326NH 4 GF325NR GF326NRH 4 400 400 GF325N GF325N GF325NR 4 4 600 GF326NH GF326NRH 4 600 GF326N GF326NR 4 600 GF326NH GF326NRH 4 GF326NRH 600 600 GF326NH GF326N GF326NR 4 600 GF326N GF326NR 600 GF326N GF326NR 240V Non-Fusible 240V Non-Fusible 240V Non-Fusible 2P or 3P 240V AC / 250V DC 240V Non-Fusible or 3P 240VACAC / 250V 2P2P or 3P 240V / 250V DCDC 2P or 3P 240VOutdoor AC / 250V DC Indoor IndoorIndoor Outdoor Outdoor Type 1 Type 3R Outdoor Type 1 Indoor Type 3R3R 1 Type AmpereCatalogType Catalog Catalog Type 1 Type 3R Ampere Catalog Ampere Catalog Catalog System Rating Number Number Number Ampere Catalog Catalog System Rating System Rating Number Number Number 30 GNF321 GNF321R System Rating Number Number 30 GNF321GNF321 GFN321R 30 GNF321R 60 GNF322 GNF322R 30 GNF321 GNF321R 60 GNF322 GNF322R 60 GNF322GNF322 100 GNF323 GNF322R GNF323R 60 GNF322R 100 GNF323R 200 GNF323GNF323 GNF324 GNF323R GNF324R GNF323 GNF323R 100 100 200 GNF324 GNF324R 400 GNF325 HNF365R GNF324 GNF324R 200 200 GNF324 GNF324R 400 GNF325 HNF365R Use 600V Switch 400 GNF325 HNF365R Use 600V Switch HNF365R HNF366R Use 600V Switch 400 600 GNF325GNF326 useHNF366R 600V Switch 600 GNF326 Use 600V Switch 600 GNF326 HNF366R Use 600V Switch HNF366R Use 600V Switch 600 GNF326 use 600V Switch 1 These switches are UL listed for application on grounded B-phase systems. 1 2These switches are listed for application grounded B-phase systems. Suitable for use onUL 3-phase motor loads. on 1 These switches are UL listed for application on grounded B-phase systems. 2 3Suitable use onare 3-phase motor loads. entrance rated. 1Service Thesefor switches UL listed for application on grounded B-phase systems. 2 Suitable for use on 3-phase motor loads. 3 4Service entrance rated. 2Height reduced (45.25" rather than 56" in height) for use with 500MCM or Suitable for useswitches on 3-phase motor loads. 3 Service entrance rated. 4 Height 3smaller reduced switches Service entrance rated.(45.25" rather than 56" in height) for use with 500MCM or conductors. 4 Height reduced switches (45.25" rather than 56"56” in in height) forfor useuse with 500MCM oror 4 Height reduced switches (45.25” rather than height) with 500MCM smaller conductors. smaller conductors. smaller conductors. Heavy Duty Safety Switches Features: n Quick-make, quick-break operating mechanism that ensures positive operation. n Visible blade, double-break switching action. n Arc chutes dissipate head and prolong switch life. n Highly visible red handle grip. Designed for hook stick operation. n Defeatable dual cover interlock. n Center punch provided for field drilling to allow ON padlocking. n Handle can be padlocked in the OFF position with up to (3) padlocks with 5/16” hasps. n Generous top, bottom and side gutters that meet or exceed NEC wire-bending space requirements. n Informative door labeling which includes replacement parts list. n Tangential knockouts through 600A for easy conduit lineup. n Side-hinged door that opens past 180 degrees for easier wiring. n Unique enclosure design increases rigidity and prevents cuts and scrapes to conductors and installer’s hands. n Spring reinforced fuse clips that assure reliable contact for cool operation. n Door latch securely holds door closed and allows cover padlocking. n Front removable mechanical lugs that are suitable for CU/AI 60 or 75º C conductors. n Lugs are field convertible to copper body and to a wide variety of compression connectors. n Hinged clear line terminal shield with probe holes for inspecting or testing line side terminals. n Embossed aluminum nameplate on Heavy Duty Switches provides highly visible ON/OFF indication. n Drawn cover for increased rigidity and resistance to abuse. n Top key hole and bottom mounting holes provide easy 2 to 3 point mounting. NEW-SPP Pocket Refer Guide :PBBR-REFGD-0510 7/26/10 4:57 PM Page 40 NEW-SPP Pocket Refer Guide :PBBR-REFGD-0510 7/26/10 4:57 PM Page 40 Heavy Duty Safety Switches General Duty Safety Switches 3 240V Fusible General Duty Safety Switches 1 240V Fusible 2P, 2F, and Neutral 2P, 2F, and Neutral 1 2 3 240V Fusible 2P, 2F, and Neutral 1 2 3 240V AC / 250V DC 240V AC / 250V DC Indoor Outdoor 240V AC 3R / 250V DC Outdoor Type 1Indoor Type Type 1 Type 3R Ampere Catalog Catalog Indoor Outdoor Ampere Catalog Catalog System Rating Number Number Type 1 Type 3R System Rating Number Number AmpereHF221N Catalog Catalog 30 30 HF221NR GF221N GF221NR System Rating Number Number 60 60 HF222N HF222NR GF222N GF222NR 30 GF221N GF221NR GF223N GF223NR 100 100 HF223N HF223NR 60 GF222N GF222NR GF224N GF224NR 200 200 HF224N HF224NR 100 GF223N 4 GF223NR 400 GF225NH GF225NRH 42 2 GF224N GF224NR 400 200 HF225NH HF225NRH 400 GF225N 4 GF225NR 4 400 GF225NH GF225NRH 400 600 HF225N GF226NH 4 HF225NR GF226NRH 4 400 GF225N GF225NR 2 600 600 HF226NH HF226NRH GF226N GF226NR 24 600 GF226NH 4 GF226NRH 600 600 HF226N HF226NR GF226N GF226NR HF227N 3P, 3F, and Neutral 3 800 240VHF227NR AC / 250V DC HF228N n HF228NR nDC 240V AC / 250V 3P, 3F, and Neutral 3 1200 Indoor Outdoor 3P, 3F, and Neutral System System 30 60 100 200 400 400 600 600 800 Type 1 Type AC 3R / 250V DC 240V Indoor Outdoor Ampere Catalog Catalog HF321N HF321NR Type 1 Type 3R Number Number Rating Ampere HF322N Catalog Catalog HF322NR 30 GF321N GF321NR Number Number Rating HF323N HF323NR 60 GF322N GF322NR 30 GF321N GF321NR HF324N HF324NR 100 GF323N GF323NR 60 GF322N GF322NR 200 GF324N GF324NR 2 HF325NH HF325NRH 100 GF323N GF323NR 2 400 GF325NH 4 GF325NRH 4 HF325N HF325NR 200 GF324N GF324NR 400 GF325N 4 GF325NR 4 400 GF325NH GF325NRH 2 2 HF326NH HF326NRH 600 GF326NH 4 GF326NRH 4 400 GF325N GF325NR HF326N 600 GF326N 4 HF326NR GF326NR 4 600 GF326NH GF326NRH HF327N HF327NR 600 GF326N GF326NR 1200 HF328N HF328NR 240V Non-Fusible 2P or 3P 240V AC / 250V DC 240V Non-Fusible n Built to order. Allow 3-5 weeks for delivery. 2P or 3P 240V AC / 250V DC Indoor Outdoor 1 These switches are UL-listed for application Type on grounded B-phase systems and 1 Type 3R Indoor Outdoor are suitable for 3-phase motor applications.Catalog Ampere Catalog 1 in height) Type 3R 2 Height reduced switch (45.25 rather than 56Type inches for use with System Rating Number Number Ampere Catalog Catalog 500MCM or smaller conductors. 30 GNF321 GNF321R 3 System Rating equipment. Number Number Suitable for use as service entrance 60 GNF322 GNF322R 30 GNF321 GNF321R 100 GNF323 GNF323R 60 GNF322 GNF322R 200 GNF324 GNF324R 100 GNF323 GNF323R 400 GNF325 HNF365R 200 GNF324 GNF324R Use 600V Switch 400 GNF325 HNF365R 600 GNF326 HNF366R 600 GNF326 Use 600V Switch Use 600V Switch HNF366R Use 600V Switch 1 These switches are UL listed for application on grounded B-phase systems. 2 Suitable for use on 3-phase motor loads. These switches UL listed for application on grounded B-phase systems. 3 1Service entrance are rated. Suitable for useswitches on 3-phase motor loads. 4 2Height reduced (45.25" rather than 56" in height) for use with 500MCM or 3 Service entrance rated. smaller conductors. 4 Height reduced switches (45.25" rather than 56" in height) for use with 500MCM or smaller conductors. NEW-SPP Pocket Refer Guide Duty :PBBR-REFGD-0510 7/26/10 4:57 PM Page 40 General Safety Switches 240V Fusible 2P, 2F, and Neutral 1 2 3 Heavy Duty Safety SwitchesIndoor 240V AC / 250V DC General Duty Safety Switches Outdoor Type 1 Type 3R Catalog Catalog 240V ACDC/ 250V DC Number 240V Number AC / 250V 30 GF221N GF221NR Type 4/4X Type Indoor Outdoor 60 GF222N GF222NR 12 Type 1 4 TypeIndustrial 3R 3 Stainless 100 GF223N GF223NR Ampere Catalog Catalog Catalog Ampere Catalog 200 GF224N GF224NR Rating Number 4 Number 4 400 GF225NH GF225NRH Rating Number Number 30 GF221N GF221NR 400 GF225N GF225NR 60 GF222N 4 GF222NR 30 600 HF221S HF221J 4 GF226NH GF226NRH 100 GF223N GF223NR GF226N GF226NR 60 600 HF222S HF222J 200 GF224N GF224NR 4 100 400 HF223S HF223J GF225NH 4 GF225NRH AC / 250V DC GF225N 240V GF225NR 200 400 HF224S HF224J 600 GF226NH 4 GF226NRH 4 Indoor Outdoor 600 used for GF226N GF226NR (Also 2-Pole, 2-Wire Type 1 Type 3R Applications in 240V Fusible 1 Ampere 240V 2Fusible 2P,System 2F2F, and Neutral 1 2 3 Rating 2P, System System 3P, 3F, and Neutral 3 3P, 3F 2 240V AC / 250V Ampere 400-800A Catalogratings) Catalog Number Number Rating 240V AC /HF321J 250V DC HF321S 30 GF321N GF321NR Indoor Outdoor 60 60 HF322S HF322J GF322N GF322NR Type 1 Type 3R GF323N GF323NR 100 100 HF323J Ampere HF323S Catalog Catalog 200 GF324N GF324NR Number Number System Rating 4 4 200 400 HF324S HF324J GF325NH GF325NRH 30 GF321N GF321NR GF325N GF325NR 400 40060 HF325S HF325J n GF322N 4 GF322NR 4 600 GF326NH GF326NRH 100 GF323N GF323NR GF326N GF326NR 600 600 HF326S HF326J n 200 GF324N GF324NR 4 GF325NH 800 400 HF327S n 4 GF325NRH HF327J n 240V Non-Fusible 400 GF325N GF325NR 4 4 or 3P AC / 250V DC 600 for delivery. GF326NH240V GF326NRH n2P Built to order. Allow 3-5 weeks 600 GF326N GF326NR Indoor Outdoor System 3P, 3F, and Neutral 3 30 1 Suitable for use as service entrance equipment. Type 1 Type 3R 2 When a neutral is required use a field installed neutral kit. Ampere Catalog Catalog 240V Non-Fusible 3 Also rated Type 3S/3R. System Rating Number Number 2P or 3P 240V AC / 250V DC 4 304 grade stainless steel. 30 GNF321 GNF321R Indoor Outdoor 60 GNF322 GNF322R Type 1 Type 3R 100 GNF323 GNF323R Ampere Catalog Catalog 200 GNF324 GNF324R System Rating Number Number 400 GNF325 HNF365R 30 GNF321 GNF321R Use 600V Switch 60 GNF322 GNF322R 600 GNF326 HNF366R 100 GNF323 GNF323R Use 600V Switch 200 GNF324 GNF324R 400 GNF325 HNF365R 1 These switches are UL listed for application on grounded B-phase systems. 2 3 4 Use 600V Switch Suitable for use on 3-phase motor loads. Service entrance rated. 600 GNF326 HNF366R Height reduced switches (45.25" rather than 56" in height) for use withUse 500MCM or 600V Switch smaller conductors. 1 2 3 4 These switches are UL listed for application on grounded B-phase systems. Suitable for use on 3-phase motor loads. Service entrance rated. Height reduced switches (45.25" rather than 56" in height) for use with 500MCM or smaller conductors. DC NEW-SPP Pocket Refer Guide :PBBR-REFGD-0510 7/26/10 4:57 PM Page 40 NEW-SPP Pocket Refer Guide :PBBR-REFGD-0510 7/26/10 4:57 PM Page 40 Heavy DutyGeneral SafetyDuty Switches Safety Switches General Duty Safety Switches 4 600V 240V Fusible Fusible 2P, 2F 480V ACAC/ /600V AC / 600V DC 240V Fusible 240V 250V DC 2P, 2F, 3and Neutral 1 2 3 2P, 2F, and Neutral 1 2 3 240V AC / 250V DC Outdoor Outdoor Outdoor Type 3R Type 3R Type 3R Catalog Catalog Catalog System Number System Number System Number GF221NR 30 GF221N GF221NR 60 GF222N GF222NR 30 HF261 HF261R NEW-SPP Pocket Refer Guide :PBBR-REFGD-0510 4:57 PM Page 40 60 GF222N 7/26/10 GF222NR 100 GF223N GF223NR 60 200 HF262 HF262R 100 GF223N GF223NR GF224N GF224NR 4 4 200 GF224N GF224NR GF225NH GF225NRH 100 400 HF263 HF263R 400 GF225NH 4 GF225NR GF225NRH 4 400 GF225N 400 600 HF265 n 4 GF226NRH HF265R n 4 400 GF225N GF225NR GF226NH General Duty Switches 600 Safety GF226N GF226NH 4 GF226NR GF226NRH 4 600 600 HF266 n HF266R n 600 GF226N GF226NR 240V Fusible 3P, 3F 480V AC / 600V AC / 250V DC 1 240V AC AC//250V 250VDC DC 2P,3P, 2F,3F, and Neutral and Neutral1 32 3 3 HF361 240V AC HF361R / 250V DC 3P, 3F, and Neutral 30 Indoor Outdoor Indoor Outdoor 5 30 HF361L HF361RL Indoor Outdoor Type Type 3R Type 115 Type 3R Type 1 Type 3R Ampere HF362 Catalog Catalog Catalog Catalog 60 Ampere HF362R Ampere Catalog Catalog Number Number System Rating System Rating Number Number Number Number System Rating — GF321N 60 3030 HF362RL 5 GF321NR GF221N GF221NR 30 GF321N GF321NR 60 GF322N GF322NR GF222N GF222NR 100 6060 HF363 HF363R GF322N GF322NR 100 GF323N GF323NR GF223N GF223NR 200100 HF364 HF364R 100 GF323N GF323NR 200 GF324N GF324NR 200 GF224N GF224NR 4 200 GF324N GF324NR 2 44 2 400 GF325NH GF325NRH 4 400400 HF365H HF365RH GF225NH GF225NRH 400 GF325NH 4 GF325NR GF325NRH 4 400 GF325N GF225N GF225NR 400400 HF365 HF365R 400 GF325N 4 GF325NR 4 600 GF326NH GF326NRH 4 4 GF226NH GF226NRH 4 4 2 2 600 GF326NH GF326NRH 600 GF326N GF326NR 600600 HF366H HF366RH 600 GF226N GF226NR 600 GF326N GF326NR Indoor Indoor Indoor Type Type 11 Type 1 Ampere Catalog Ampere Catalog Ampere Catalog Rating Number Rating Number Rating Number 30 GF221N 600 800 1200 3P, 3F and Solid Neutral 240V Non-Fusible 3P,2P 3F, Neutral 3 240V Non-Fusible orand 3P 2P or 3P System System System HF366 HF367 HF368 HF366R HF367R 240V AC AC//250V 250VDC DC 240V 240V AC HF368R / 250V DC Indoor Outdoor Indoor Outdoor 480V ACType / 600V Type 1 Type 3R AC / 250V DC 1 Indoor Outdoor Type 3R Type 1 Type 3R Ampere Catalog Catalog Ampere Catalog Catalog 30 Rating HF361N HF361NR Ampere Catalog Catalog Number Number Rating Number Number Number Number 60 30Rating HF362N HF362NR 30 GNF321 GNF321R GF321N GF321NR 30 GNF321 GNF321R GNF322 GNF322R GF322N GF322NR 100 606060 HF363N HF363NR GNF322 GNF322R 100 GNF323 GNF323R 100 GF323N GF323NR 200200 HF364N HF364NR 100 GNF323 GNF323R 200 GNF324 GNF324R GF324N GF324NR 200 GNF324 4 GNF324R 4 400 GNF325 HNF365R GF325NH GF325NRH 400400 HF365N HF365NR 400 GNF325 HNF365R Use 600V Switch GF325N GF325NR 600400 HF366N HF366NR Use 600V Switch 600 GNF326 HNF366R 4 4 600 GF326NH GF326NRH GNF326 HNF366R Use 600V Switch 800600600 HF367N HF367NR GF326N GF326NR Use 600V Switch 1200 HF368N HF368NR 1 These switches are UL listed for application on grounded B-phase systems. 21 Suitable for use on motor loads. These switches are3-phase UL listed for application on grounded B-phase systems. 240V Non-Fusible n3Built toentrance order. Allow 3-5motor weeks for delivery. 2Service Suitable for use rated. on 3-phase loads. 2P4or 3P reduced 240V / 250V 3Height switches with AC 500MCM or DC Service entrance rated. (45.25" rather than 56" in height) for use 4smaller 1 60-200A Heightconductors. reduced (45.25" 56" 600V in height) for use with 500MCM or 3-Poleswitches switches arerather alsothan rated IndoorDC. Outdoor smaller conductors. 2 Height reduced switch (45.25 rather than 56 inches in height) for use with Type 1 Type 3R 500MCM or smaller conductors. Ampere Catalog Catalog 3 Use 3-Pole switch for 200A applications. System Rating Number Number 4 Suitable for use as service entrance equipment except on1200 Amp solidly 30 GNF321 GNF321R grounded wye systems per NEC 230.95. 60 GNF322 GNF322R 5 Indicates oversized enclosure (30A switch with 60A lugs in a 60A enclosure or 100 GNF323 GNF323R 60A switch with 100A lugs in a 100A enclosure). 200 GNF324 GNF324R 400 GNF325 HNF365R Use 600V Switch 600 GNF326 HNF366R Use 600V Switch 1 2 3 4 These switches are UL listed for application on grounded B-phase systems. Suitable for use on 3-phase motor loads. Service entrance rated. Height reduced switches (45.25" rather than 56" in height) for use with 500MCM or smaller conductors. NEW-SPP Pocket Refer GuideDuty :PBBR-REFGD-0510 General Safety Switches7/26/10 4:57 PM Page 40 240V Fusible General Duty Safety Switches 1 2 3 2P, 2F, and NeutralSafety Heavy Duty Switches 240V AC / 250V DC General Duty SafetyIndoor Switches Outdoor 240V Fusible 2 3 Type 240V 1 AC /Type 250V3R DC 2P, 600V 2F, and Fusible Neutral 1 1 Ampere Catalog Catalog 2P,240V 2F 2Fusible 480V AC / 600V AC / 600V DC Indoor Outdoor 240V AC / 250V DC 2P, 2F, and Neutral 1 2 3 Rating System Number Number Type 1 4X Type 3R Type 12 3 Type 30 GF221N GF221NR Indoor Catalog Outdoor Ampere Catalog Stainless Industrial 60 GF222N GF222NR Type 1 Number Type 3R System Rating Number NEW-SPP Pocket Refer GuideAmpere :PBBR-REFGD-0510 7/26/10GF223NR 4:57 PM Page 40 Catalog Catalog 100 GF223N Ampere Catalog Catalog 30 GF221N GF221NR 200 GF224N GF224NR System Rating Number Number System NumberGF222NR Number 60 Rating GF222N 4 4 400 GF225NH GF225NRH 30 GF221NGF223NR GF221NR 100 GF223N 30 HF261S HF261J n GF225N GF225NR GF222NGF224NR GF222NR 200 40060 GF224N 4 4 600 GF226NH GF226NRH HF262S 4 4 HF262J n 100 GF223N GF223NR 400 GF225NH GF225NRH General60 Duty Safety Switches 600 GF226N GF226NR GF224NGF225NR GF224NR 400 200 GF225N 100 HF263S n HF263J n 4 4 4 4 GF225NH GF225NRH 600 400 GF226NH GF226NRH 240V Fusible 1 2 3 600 400 GF225N HF265S n240V HF265J AC AC /GF225NR 250V DC DC n 2P, 3P, 2F, 3F, andand Neutral GF226N GF226NR 240V / 250V Neutral 3 400 600 GF226NH 4 GF226NRH 4 600 600 HF266S n HF266J n Indoor Indoor Outdoor GF226N Outdoor GF226NR Type 1 480V Type 3R Type 1 3R 240V AC /Type 250V DC AC / 250V DC 3P, 3P, 3F, and 3F Neutral 3 AC / 600V Ampere Catalog Catalog Ampere Catalog Catalog Indoor Outdoor HF361S System Number 240V ACHF361J / 250V DC 3P, 3F, and Neutral 330Rating Number Number Number System Rating Type 1 Type 3R 30 30 GF221N GF221NR GF321N GF321NR 60 HF362S HF362J Indoor Catalog Outdoor Ampere Catalog 60 GF222N GF222NR GF322N GF322NR Type 1 Number TypeHF363J 3R Number System Rating60 100 HF363S 100100 GF223N GF223NR GF323N GF323NR Ampere GF321N Catalog GF321NR Catalog 30 200 GF224N GF224NR 200 GF324N GF324NR 200 HF364S HF364J NumberGF322NR Number System Rating GF322N 60 4 4 GF225NRH 4 4 400400 GF225NH GF325NH GF325NRH 30 GF321NGF323NR GF321NR 100 GF323N 400 HF355S HF365J 400400 GF225N GF225NR GF325N GF325NR 60 GF322N GF322NR 200 GF324N 4 GF324NR 4 4 600600 GF226NH 4 GF226NRH 600 HF366S HF366J GF326NH GF326NRH 4 4 100 GF323N GF323NR 400 GF325NH GF325NRH 600600 GF226N GF226NR GF326N GF326NR GF324NGF325NR GF324NR 800 HF367S HF367J n 400 200 GF325N 4 4 4 4 GF325NH GF325NRH 600 400 GF326NH GF326NRH 1200 HF368S n240V HF368J n GF325N AC /GF325NR 250V DC 3P, 240V 3F, and Neutral 3 600 400 GF326N GF326NR Non-Fusible 4 4 600 GF326NH240V AC GF326NRH 2P or 3P / 250V DC Indoor 600 GF326N Outdoor GF326NR 600V Non-Fusible 1 Type 1 Type 3R Indoor Outdoor 240V Non-Fusible 2 Ampere Catalog Catalog 2P,3P2F 480V AC / 600V Type 1 3R 2P or 240V AC /Type 250V DC AC / 600V DC Number Number System Rating 240V Non-Fusible Ampere Type Catalog Catalog 4X Type 12 3 Indoor Outdoor 2P or 3P 240V AC / 250V DC 30Rating GF321N System Number GF321NR Number Type 1 Type 3R Industrial Stainless 60 30 GF322N GF322NR GNF321 GNF321R Indoor Outdoor Ampere Catalog Catalog Ampere Catalog Catalog 100 GF323N GF323NR GNF322 GNF322R Type 1 Number Type 3R System Rating 60 Number System Rating Number Number 200100 GF324N GF324NR GNF323 GNF323R Catalog GNF321R Catalog 30 Ampere GNF321 4 4 400200 GF325NH GF325NRH GNF324 GNF324R System NumberGNF322R Number 30 HNF261S HNF261J 60 Rating GNF322 40040030 GF325N GF325NR GNF325 HNF365R GNF321 GNF321R 100 GNF323 GNF323R 4 4 60600 60 HNF262S HNF262J GF326NH GF326NRH Use 600V Switch GNF322GNF324R GNF322R 200 GNF324 600 100 GF326N GF326NR GNF326 HNF366R 100 GNF323 GNF323R nHNF365R HNF263J n HNF263S 400 600 GNF325 Use 600V Switch 200 GNF324 GNF324R Switch 400 400 HNF265S nUse 600VHNF365R HNF265J n 600 GNF326GNF325HNF366R 240V Non-Fusible 1 These switches are UL listed for application on grounded B-phase systems. 600V Switch n 600 HNF266S 240V nUse 600V HNF266J 2P or 3P AC /Use 250V DC Switch 2 Suitable for use on 3-phase motor loads. 600 GNF326 HNF366R 3 Service entrance rated. Indoor 480VOutdoor 3P, 3F are UL switches AC500MCM / 600V AC / 250V DC 1 These 600V Switch 4 switches listed for (45.25" application on than grounded Height reduced rather 56" inB-phase height)systems. for use withUse or Type 1 Type 3R 2 Suitable for useconductors. on 3-phase motor loads. smaller 30 HNF361S HNF361J Ampere Catalog Catalog 3 Service1 entrance rated. are UL listed These switches for application on grounded B-phase systems. System Rating Number Numberor 4 Height (45.25" rather than 56" in height) for use with 2reduced Suitableswitches for use on 3-phase motor loads. 4 500MCM 60 HNF362SH HNF362JH 4 smaller3 conductors. Service entrance rated. 30 GNF321 GNF321R 4 Height reduced switches 60 HNF362S HNF363J (45.25" rather than 56" in height) for use with 500MCM or 60 GNF322 GNF322R smaller conductors. 100 GNF323 GNF323RHNF363J 100 HNF363S 200 GNF324 GNF324R 200 HNF364S 400 GNF325 HNF365RHNF364J 400 HNF355S Use 600V Switch HNF365J 600 GNF326 HNF366R 600 HNF366S HNF366J Use 600V Switch 800 HNF367S HNF367J n 1 These switches are UL listed for application on grounded B-phase systems. 1200 HNF368S n HNF368J n 2 Suitable for use on 3-phase motor loads. 3 4 Service entrance rated. Height reduced switches (45.25" than for 56" in height) for use with 500MCM or n Built to order. Allow 3-5rather weeks delivery. smaller conductors. 1 Suitable for use as service entrance equipment except on1200 Amp solidly grounded wye systems per NEC 230.95. 2 Use 3-Pole switch for 200A applications. 3 Also rated Type 3S/3R. 4 Compact switch (11.1”H, 6.6”W box less cover and handle). Short circuit withstand rating – 100,000 RMS Sym. amps. Heavy Duty Safety Switches Type 4/4X & 12 with Viewing Window Description 30–600A, 3-pole 600V max. in fusible and non-fusible versions in Type 4/4X stainless steel and Type 12 enclosures. All allow viewing of visible blade position. 30–200A also allow viewing of indicating type fuses. Features: n Rugged installer-friendly enclosure design features a gasket flange with continuously welded seams n Tool-free cover latches n Two, three and four point mounting n Metal handle with large insulating grip features a positive stop in both ON and OFF position n Ground lugs provided as standard n Type 12 enclosures are fabricated from galvanized steel and are also rated for 3R/3S outdoor applications n The widest range of accessories available including 200% neutrals, gold plated PLC auxiliary contacts and isolated ground kits 100 GF223N GF223NR Indoor Indoor Outdoor Outdoor 200 GF224N GF224NR Type 1 3RType 3R 4 400 GF225NH GF225NRH Type 1 4 Type Ampere Catalog Catalog 400 GF225N GF225NR Ampere Catalog Catalog General Duty Safety NumberSwitches Number System Rating 4 4 600 GF226NH GF226NRH System Rating NumberGF321NR Number 30600 GF321N GF226N GF226NR 240V Fusible GF221N GF322NR GF221NR 6030 GF322N 1 2 3 240V AC / 250V DC 2P, 2F, and Neutral 10060 GF323N GF222N GF323NR GF222NR 240V AC / 250V DC 3P, 3F, and Neutral 3 200 GF324N GF324NR 100 GF223N GF223NR Indoor 4 4 400 GF325NH GF325NRHOutdoor 200 GF224N GF224NR Indoor Outdoor Type 1GF325NR Type 3R 400 GF325N Ampere Catalog 4TypeGF225NRH 4 Type 14 3R 4 400 GF225NH Ampere GF326NH Catalog Catalog 600 GF326NRH Ampere Catalog Catalog System Rating Number 400 GF225N GF225NR 600Rating GF326NR System Rating GF326N Number Number Number Number System Heavy Duty Safety Switches Type 4/4X & 12 with Viewing Window 4 4 600Type GF226NH GF226NRH 600V AC / 250V DC 1 3-Pole, 3-Wire Fusible, 3R 3GF321N GF221N GF321NR GF221NR 3030 600 60 GF226N GF322N GF226NR GF322NR 60 GF222N GF222NR 240V Non-Fusible NEW-SPP Pocket Refer Guide 7/26/10 4:57 PM Page 40 100 GF323N240V AC GF323NR 2P or 3P / 250V DC HF361RW 30:PBBR-REFGD-0510 100 200 200 3P, 3F, and Neutral 3 400 400 400 60Ampere 400 600 System Rating 600 600 General 30 Duty GF223N GF223NR GF324N GF324NR GF224NR Indoor GF224N Outdoor 240V AC / 250V DC 4 4 GF325NH GF325NRH 43R GF225NRH 4 Type 1 GF225NH Type GF325N GF325NR HF362RW Catalog Catalog Indoor Outdoor GF225N GF225NR 4 4 GF326NH GF326NRH Number Type 1 Number 3R 4 Type 4 GF226NH GF226NRH GF326N GF326NR Safety Switches 3 GNF321R GNF321 1 600V4:57 AC PM / 250V DC40 3-Pole, 3-Wire Type Catalog 3R Ampere Catalog NEW-SPP Pocket ReferNon-Fusible, Guide60 :PBBR-REFGD-0510 7/26/10 Page 600 GF226NR GNF322GF226N GNF322R Number Number System Rating 240V240V Fusible 100 GNF323 GNF323R Non-Fusible HNF361RW GF321N GNF324R GF321NR 1 2 330 20030 GNF324 240V AC / 250V 2P, 2F, and 2P or 3P Neutral 3 240V AC / 250V DC DC 240V AC / 250V DC 3P, 3F, and Neutral GF322N HNF365R GF322NR 40060 GNF325 Indoor Outdoor Indoor Outdoor Use 600VGF323NR Switch GF323N 60 100 HNF362RW Indoor Type 1 1 HNF366R TypeType 3ROutdoor Type 3R 600 GNF326 General Duty Safety Switches 200 GF324N GF324NR Type 1UseCatalog Type 3R Ampere Catalog 600VCatalog Switch Ampere Catalog 4 400 GF325NH GF325NRH 2, 3 Catalog 4Number 1 System3-Wire Fusible, Rating Number 600V 3-Pole, Type 12 Ampere Catalog System Rating Number Number AC / 250V DC 240V Fusible 400 GF325N GF325NR 30 GNF321 1System Number Number Rating These switches are UL listed for application on grounded B-phase systems.GNF321R 1 2 3 30 GF221N 4GNF322R GF221NR HF361JW 30 loads. 4 DC 240V AC / 250V 2P, 2F, and Neutral 2 Suitable for use on 3-phase motor 6030 GNF322 600 GF326NH GF326NRH GF321N GF321NR 3 Service entrance rated. 60 GF222N GF222NR 100 GNF323 GNF323R 600 GF326N GF326NR 4 Height reduced switches (45.25" Indoor HF362JW 60rather 60 GF322N GF322NR than 56" in height) for use with 500MCM Outdoor or 200 GNF324 GNF324R 100 GF223N GF223NR smaller conductors. Type 1 Type 3R 100 GF323N GF323NR 400 GNF325 GF224N HNF365R GF224NR HF363JW 100200 Ampere Catalog Catalog 200 GF324N4Use 600V GF324NR Switch 4 240V Non-Fusible 400 GF225NH GF225NRH 4 4 System Rating Number Number 600 GNF326 400 GF325NHHNF366R GF325NRH HF364JW 200400 2P or 3P AC / 250V DC GF225N 240VGF225NR Use 600V Switch 30 GF221N GF221NR 400 GF325N4 GF325NR4 600 GF226NH GF226NRH HF365JW 400 600 Indoor 60 GF222N 4 Outdoor GF222NR 4 GF326NH GF326NRH 1 These switches are UL listed for 600 GF226N application on grounded B-phase Type 1 systems. GF226NR Type 3R 100 GF223N GF223NR GF326N GF326NR 2 Suitable for use on 3-phase motor 600 loads. HF366JW 600 Ampere Catalog Catalog 3 Service entrance rated. 200 GF224N GF224NR System Number Number 4 Height 3-Wire 2, 3 1 reduced switches (45.25"Rating rather thanType 56" in height) for use with4500MCM or 600V 3-Pole, Non-Fusible, 12 3 400 GF225NH240V AC GF225NRH / 250VAC DC4/ 250V DC 3P, 3F,smaller and conductors. Neutral 240V Non-Fusible 30 GNF321 GNF321R 400 GF225N GF225NR HNF361JW 30 Indoor Outdoor 2P or 3P AC / 250V DC 60 GNF322 GNF322R 4 600 GF226NH 4240V GF226NRH Type 1 Type 3R GNF323 GNF323R HNF362JW 60 100 600 GF226N GF226NR Indoor Outdoor Ampere Catalog Catalog 200 GNF324 GNF324R Type 1 Type 3R HNF363JW 100Rating Number Number System 400 GNF325 HNF365R Ampere Catalog Catalog GF321N GF321NR AC / 250V 3P, 3F, and Neutral 3 200 30 Use 600V SwitchDC System Rating HNF364JW Number 240V Number 60 GF322N GF322NR 600 GNF326 HNF366R 30 GNF321 GNF321R Indoor Outdoor HNF365JW 400100 GF323N GF323NR Use 600V3R Switch Type 1 Type 60 GNF322 GNF322R 200 GF324NR Ampere Catalog Catalog 3-Pole, 3-Wire Fusible, Type 4X GF324N 100 GNF3234 GNF323R4 1 These switches are UL listed for application 400 GF325NH GF325NRH on grounded B-phase systems. Number Number System Rating 3, 4 200 GNF324 GNF324R Steel 600V AC / 250V DC 1 2 Stainless Suitable for use on 3-phase motor loads. 400 GF325N GF325NR 30 GF321N GF321NR 400 GNF325 HNF365R 3 Service entrance rated. GF326NH 4 GF326NRH 4 HF361SW 30 60060 than 56" 4 Height reduced switches (45.25" rather GF322N Use 600V Switch in height) for use with GF322NR 500MCM or 600 GF326N GF326NR smaller conductors. GF323N GF323NR 600 GNF326 HNF366R HF362SW 60 100 200 GF324N GF324NR Use 600V Switch HF363SW 100 400 GF325NH 4 GF325NRH 4 240V Non-Fusible 1 These switches are UL listed for application on grounded B-phase systems. GF325N 240V AC GF325NR 2P or 3P / 250V DC HF364SW 200 400 2 Suitable for use on 3-phase motor loads. 600 GF326NH 4 GF326NRH 4 3 Service entrance rated. Indoor Outdoor HF365SW 400 600 GF326N GF326NR 4 Height reduced switches (45.25" rather than 56" Type in height) or 1 for use with Type500MCM 3R smaller conductors. 3-Pole, 3-Wire Non-Fusible, 4X Ampere Type Catalog Catalog 3, 4 System Rating Number Number Stainless Steel 600V AC / 250V DC 1 240V Non-Fusible GNF321 GNF321R 2P or 3P 240V AC / 250V DC HNF361SW 30 30 60 GNF322 GNF322R Indoor Outdoor HNF362SW GNF323 GNF323R 60 100 Type 1 Type 3R 200 GNF324 GNF324R Ampere Catalog Catalog HNF363SW 100400 GNF325 HNF365R System Rating Number Number 200 30 600 400 60 HNF364SW GNF321 Use 600V Switch GNF321R HNF366R GNF322R 100 GNF323 GNF323R 1 200A switches are also rated200 600V DC. GNF324 GNF324R 1 These switches are UL listed for application on grounded B-phase systems. 2 Also rated Type 3S/3R. 400 GNF325 HNF365R 2 Suitable for use on 3-phase motor loads. GNF326 GNF322 HNF365SW Use 600V Switch 3 All switches are suitable for use as service entrance equipment. Use outside poles of 3 Service entrance rated. Use 600V Switch 3-pole switch for 2-pole application. 4 Height reduced switches (45.25" rather for use with HNF366R 500MCM or 600 than 56" in height) GNF326 4 304 grade stainless steel. For switches with enclosures constructed from 316 grade Use 600V Switch stainless steel. smaller conductors. 1 2 3 4 These switches are UL listed for application on grounded B-phase systems. Suitable for use on 3-phase motor loads. Service entrance rated. Height reduced switches (45.25" rather than 56" in height) for use with 500MCM or smaller conductors. Accessories Auxiliary Contacts with 1 NO and 1 NC Isolated Contacts Maximum Aux. Kit Ampere Rating Switch Switch Maximum Kit Horsepower Rating Amp Rating 30-200 400-1200 125 V AC 1/2 1/2 250 V AC 3/4 3/4 28 V DC — — — — Catalog Number HA161234 HA165678 125 V AC 10 10 250 V AC 10 10 28 V DC — — with 2 NO and 2 NC Isolated Contacts 30-200 HA261234 10 10 7 1/2 3/4 400-1200 HA265678 10 10 7 1/2 3/4 Low Current PLC Type with 1 NO and 1 NC Gold Plated Contacts 30-200 400-1200 HA361234 10 HA365678 10 10 10 — — 1/2 1/2 3/4 3/4 — — Equipment Ground Kits Switch Amp Rating 30 GD 60-200 GD 30-200 HD 400 & 600 800-1200 Catalog Number GSGK60 HG61234 HG61234 HG656 HG678 Number of Terminals 2 2 2 4 8 Wire Range Per Terminal (Cu/Al) #14-8 AWG #14-4 AWG #14-4 AWG #14-2/0 #6 AWG-250 kcmil Isolated Ground Kits Switch Amp Rating 30-200 400-600 Catalog Number HG261234 HG2656 Number of Terminals Isolated 2 4 Grounded 2 4 Wire Range Per Terminal (Cu/Al) #14-4 AWG #14-2/0 Hubs – Type 3R 1 Conduit Size Inches Cover 3/4 1 1 1/4 Cover 3/4 1 1 1/4 1 1/2 2 2 1/2 2 1/2 3 3 1/2 4 1 Suitable for 3R switches. Catalog Number ECHA000 ECHA075 ECHA100 ECHA125 ECHS000 ECHS075 ECHS100 ECHS125 ECHS150 ECHS200 ECHS250 ECHV250 ECHV300 ECHV350 ECHV400 Used On 30A GD Only 60-200A GD 30-200A HD 400-1200A Accessories Class R Fuse Clip Kits All General Duty and Heavy Duty Switches are field convertible to accept Class R Fuse Clip Kits. The kits prevent the installation of Class H and K fuses (one kit required per 3-pole switch). Class R Fuse Clip Kits Catalog Number Description GSRK321 HR21 HR612 HR62 HR63 HR64 HR656 30A, 240V Kit (GD only) 30A, 240V Kit (HD only) 30A, 600V Kit/60A, 240 Kit 60A, 600V Kit 100A Kit 200A Kit 400A / 600A Kit Class J Fusing All 30-600A, 600V and 100-600A,240V fusible Heavy Duty Switches are field convertible to accept Class J fuses by moving the load base to a pre-drilled J fuse position. All 100-600A, 240V fusible General Duty switches can also be field converted to accept Class J fuses. Class T Fuse Adapter Kits All 100-600A, General Duty and 100- 200Amp and 1200Amp Heavy Duty Switches are field convertible to accept Class T fuses. 400-800A switches are field convertible to accept Class T fuses by moving the load base to a pre-drilled T fuse position. Class T Fuse Adapter Kits 1 Catalog Number Description HT23 HT63 HT24 HT64 n TFAK82 100A, 240V Kit 100A, 600V Kit 200A 240V Kit 200A 600V Kit 1200A, 240V Kit Neutral Kits Standard Neutral Kits can be field installed in General and Heavy Duty Switches. Neutral Kits Switch Ampere Rating Kit Catalog Number 30 GD 30 HD, 60 GD 60, 100 HD, 100 GD 200 400 & 600 800 & 1200 W410190 HN612 HN623 HN64 HN656 HN678 n Built to order. Allow 6-8 weeks for delivery. 1 One kit per 3 pole switch required. Accessories 200% Neutral Kits 1 UL listed 200% Neutrals are available for 100-600A Heavy Duty Switches. They are typically used with non-linear transformers or where increased neutral ampacity/lug capacity is required. 200% Neutral Kits 1 Switch Ampere Rating Kit Catalog Number Wire Range Line & Load Lugs (Cu/Al) 100 200 HN263 HN264 400 HN656 600 HN678 (2) #14-1/0 AWG (2) #6 AWG - 300 Kcmil (2) 1/0 AWG - 750 Kcmil or (4) 1/0 AWG - 250 Kcmil (4) 1/0 AWG - 750 Kcmil Internal Shield Kits (for fusible switches) Kits provide a clear plastic inner door to prevent accidental contact with live parts. Test probe holes are provided and fuses can be replaced without removal of kit. Internal Shield Kits 2 Switch ampere rating Kit Catalog Number 30A HD 60A HD 100A HD 200A HD HSK61SSW HSK62SSW HSK63SSW HSK64SSW Fuse Puller Kits Fuse puller kits are field installable in 30-100A Type VBII Heavy Duty Switches (one kit required 3-pole switch). Fuse Puller Kits Switch ampere rating Kit Catalog Number 30 60 100 HP61 HP62 n HP63 n n Built to order. Allow 6-8 weeks for delivery. 1 One kit per 3 pole switch required. 2 Not designed for use in Non-metallic 4X safety switches. Not designed for use with Auxiliary Contacts. Accessories Quick Connects They provide two point control power take-off capability and are normally used on two poles on the line side when it is required to have control power available when the switch is in the OFF position. They provide a mounting provision for standard ¼” quick connect terminal. Installed in the line or load side. 30A VBII switches have lugs UL listed to accept (2) wires per pole as standard so a 30A kit is not required. Quick Connects Catalog Number Description HCQ62 HCQ63 HCQ64 60A 2 wire quick connect kit 100A 2 wire quick connect kit 200A 2 wire quick connect kit Copper Lug Kits Heavy duty switches are UL approved to accept field installed copper lug kits. Copper Lug Kits Switch Ampere Rating 30-60 100 200 Catalog Number HLC612 HLC63 n HLC64 n Description (9) Lugs/Kit #14-4 AWG Cu (9) Lugs/Kit #14-1/0 AWG Cu (9) Lugs/Kit #6 AWG-300 Kcmil Cu 400-1200 HLC65678 (1) Lugs/Kit #1/0 AWG-600 Kcmil Cu n Built to order. Allow 6-8 weeks for delivery. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. Subject to change without prior notice. Order No: PBBR-REFGD-0215 All rights reserved. Printed in USA © 2015 Siemens Industry, Inc. Siemens Industry, Inc. 5400 Triangle Parkway Norcross, GA 30092 1-800 -241- 4453 info.us@siemens.com www.usa.siemens.com/powerdistribution