guideline specifications

advertisement
REDUCED-PROFILE, QUICK-DISCONNECT
FLUORESCENT BATTERY PACKS
®
GUIDELINE SPECIFICATIONS
General
The
battery pack shall be of the Power Sentry® family. The battery pack shall be capable of operating one
T8-T12 lamps, one 2’-4’
HO or VHO long compact
lamp (PS600QD
or two 2’-4’
and PS1400QD), one 6’-8’ T8-T12 lamp (PS600QD and PS1400QD), one 2’-4’ T5 lamp (PS600QD and PS1400QD),
one 2’-4’ T5HO lamp (PS600QD and PS1400QD), one or two 13-32W four-pin compact
lamps (PS1400QD), or
lamp (PS1400QD) for 90 minutes. The unit shall be constructed to conform to the
one 42W four-pin compact
the standards of the National Electrical Code, OSHA, and the current Life Safety Code (NFPA 101). The product shall be
UL-listed.
Maintenance
The battery pack shall be equipped with a Quick-Disconnect wire harness. This plug-and-play connector system will allow
without cutting or rewiring.
the battery pack to be quickly replaced in the
Construction
The battery pack case shall be a reduced-pr
injection-molded housing which meets UL94V-0
rating requirements.
Dimensions shall not exceed 9.4 inches L x 2.19 inches W x 1.18 inches H (PS300QD, PSQ500QD, PS600QD), 13.3 inches L x
2.19 inches W x 1.18 inches H (PS1400QD).
Battery
Batteries shall be maintenance-free, high-temperature/high-capacity C-cell nickel cadmium type.
Mounting
Integral test switch/pilot light should be provided for ease of installation. The battery pack shall be either concealed in the
ballast channel or external to the
A remote test switch shall be available as an option.
Operation
During normal operation, the AC power applied to the battery pack is regulated and controlled by the electronic circuitry to
provide proper automatic charging of the battery. Upon loss of the normal utility power, the electronic circuitry will automatically
lamps up to the initial lumen output
(ranges from 300-1400 lumens). The battery pack
operate one or two
shall evenly divide the light output between two lamps where two-lamp operation is available (PS600 and PS1400). The battery
pack shall permit one or two lamp optimization with the use of a
selector switch. The
battery pack shall deliver
spacing up to 59’ on center while meeting the Life Safety Code requirements of one foot-candle average, 0.1 foot-candle minimum,
and a max-to-min ratio of 40:1.
Electronics
The electronics shall consist of a constant current-type battery charger designed to provide increased reliability and maximize
battery life. The charging circuitry shall be capable of automatically recharging the battery. Dual-input voltage (120/277 VAC,
60HZ) capability shall be standard.
Self-diagnostics Module
The self-diagnostics module shall be contained in a separate housing with Quick-Disconnect capability for easy maintenance. An
integral multi-chromatic test switch/pilot light indicator will be provided to display two-state charging, test activation and threestate diagnostic status. Test switch also provides manual activation of 30-second diagnostic testing for on-demand visual
inspection. The self-diagnostic testing will occur for
minutes every 30 days and 30 minutes every six months for diagnostic
evaluation of lamps, AC to DC transfer, charging and battery condition. The self-diagnostic platform will continuously monitor AC
installation.
functionality. The self-diagnostics module shall be available for factory or
Additional Options
Damp/Wet Location: This option provides a UL-approved
xtures at temperatures of 0-50° Celsius.
Warranty
A five-year total customer satisfaction warranty shall be provided for all
products with the exception of those with 500 lumen output or less.
Products with 500 lumen output or less shall have a three-year total
customer satisfaction warranty.
battery pack for use in wet and damp location listed