Datablad Appleton ATX PN Serie

advertisement
PN Series Floodlights – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for simultaneous exposure to gas, combustible dusts and flammable gases or vapors.
Zone 2, 21 and 22
II 2 D II 3 GD
ATEX / IECEx
IP66 - IK07/08
Applications
• Powerful, efficient floodlights for large areas such as industrial
complexes and ship loading areas.
• Rated for use in hazardous areas.
Features
• Highly efficient, integrally ballasted floodlight. Has compact,
lightweight, yet rugged die cast aluminum construction.
• Simple installation and maintenance.
• Integral ballast; 230/240 V, 50 Hz.
• One-piece lens cover.
• Heavy duty, high temperature silicone rubber gasket, firmly
seated.
• Socket: E40 (E27 for 70 W HPS version).
• Reflectors: double segment compound parabolic with finish for
maximum efficiency.
• Mounting: yoke mount.
Standard Materials
• Ballast housing and lens door: copperfree (4/10 of 1% max.)
aluminum
• Gasket: silicone rubber
• Socket: heavy duty porcelain with heavy gauge brass shell
• Reflector: finished aluminum
• Yoke mount: zinc plated steel
• Bolts: stainless steel
Standard Finishes
• Ballast housing, lens cover, yoke and pole mount: architectural
bronze polyester
• Socket: nickel-plated
• Size M — Certification Type PJn
— Gas: Zone 2
 Conforming to ATEX 94/9/CE: CE
3G
 ATEX/IEC Protection: Ex nR II
 T Rating: T2 to T4
 Ambient Temperature: 104 °F to 131 °F/40 °C to 55 °C
— Dust: Zone 22
 Conforming to ATEX 94/9/CE: CE
II 3 D
 ATEX/IEC Protection: Ex tD A22
 Surface Temperature: T243 °F/T117 °C to 442 °F/T228 °C
— Gas, Zone 2 and Dust, Zone 22
 Ambient Temperature: 104 °F to 131 °F / 40 °C to 55 °C
 ATEX Certificate: LCIE 08 ATEX 6035X
 IEC Certificate: IECEx LCI 04.0015
 Other Certifications: GOST
 Impact Resistance (shock): IK07
— Dust: Zone 21
 Conforming to ATEX 94/9/CE: CE
I2D
 ATEX/IEC Protection: Ex tD A21
 Surface Temperature: T149 °F to T277 °F/T65 °C to
T136 °C
 Ambient Temperature: -4 °F to 104 °F/-20 °C to 40 °C
 ATEX Certificate: LCIE 02 ATEX 6246X
 Impact Resistance (shock): IK07 with glass diffuser, IK08
with polycarbonate diffuser
— CE Declaration of Conformity: 50251
— Index of Protection (solid and liquid): IP66
Lighting
LIGHTING: ENCLOSED AND GASKETED — FLOODLIGHT
Certifications and Compliances
• Size G — Certification Type PJn
— Gas: Zone 2
 Conforming to ATEX 94/9/CE: CE
3G
 ATEX/IEC Protection: Ex nR II
 T Rating: T3
— Dust: Zone 22
 Conforming to ATEX 94/9/CE: CE
II 3 D
 ATEX/IEC Protection: Ex tD A22
 Surface Temperature: T369 °F to T378 °F/T187 °C
to T192 °C
— Gas, Zone 2 and Dust, Zone 22
 Ambient Temperature: 104 °F to 131 °F/40 °C to 55 °C
 CE Declaration of Conformity: 50215
 ATEX Certificate: LCIE 08 ATEX 6035X
 IEC Certificate: IECEx LCI 04.0015
 Other Certifications: GOST
 Impact Resistance (shock): IK07
— Dust: Zone 21
II 2 D
 Conforming to ATEX 94/9/CE: CE 008
 ATEX/IEC Protection: Ex tD A21
 Surface Temperature: T250°F to T360°F / T121°C
to T182°C
 Ambient Temperature: -4°F to 104°F / -20°C to 40°C
 CE Declaration of Conformity: 50274
 ATEX Certificate: LCIE 02 ATEX 6246X
 Impact Resistance (shock): IK07 with glass diffuser, IK08
with polycarbonate diffuser
— Index of Protection (solid and liquid): IP66
• Ex Standards: EN/IEC 60079-0, 60079-15, 61241-0, 61241-1
• Product Standards: EN/IEC 60598-1
• EMC Standards: EN/IEC 55015, 61547
• Other Standards: EN/IEC 60529 (IP)
1166
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© January 2011
PN Series Floodlights – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for simultaneous exposure to gas, combustible dusts and flammable gases or vapors.
Zone 2, 21 and 22
II 2 D II 3 GD
ATEX / IECEx
IP66 - IK07/08
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide For PN Series Luminaires
PN
P
Series:
PN - PN Series
Zone 2, 21 & 22
ATEX / IEC Certified
Body Size:
P - Small
M - Medium
L - Large
1
H
Mounting:
1 - Yoke
5 - Pole Slip-fit
70
Wattage:
70 - 70 W
15 - 150 W
25 - 250 W
40 - 400 W ①
99 - 1000 W ①
Lamp Type:
H - Metal Halide
L - Sodium
M - Mercury
A
G
MT
Diffuser:
G - Glass
P - Polycarbonate ②
Entry Size:
A - M20
F
Options:
S - Stainless Steel
Housing
Options:
XA - 220 Vac 50 Hz
(Magnetic Ballast)
XJ - 230/240 Vac 50 Hz
(Magnetic Ballast)
LIGHTING: ENCLOSED AND GASKETED — FLOODLIGHT
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© January 2011
Lighting
① 400 W Zones 21-22 and 1000 W Zones 2-22 only with large body (suffix -G).
② Zone 2-22 doesn’t exist with polycarbonate diffuser.
1167
PN Series Floodlight T Ratings – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for simultaneous exposure to gas, combustible dusts and flammable gases or vapors.
Zone 2, 21 and 22
II 2 D II 3 GD
ATEX / IECEx
IP66 - IK07/08
Zone 21 (Dust)
Dust Surface Temperatures for Ta = 104 °F/40 °C
Operating Position
Body Size: M
Body Size: L
Lamp and Power
70 W Sodium
150 W Sodium
250 W Sodium
250 W Metal Halide
250 W Mercury
400 W Sodium
1000 W Sodium
1000 W Metal Halide
Glass Diffuser
167 °F/75 °C
213.8 °F/101 °C
260.6 °F/127 °C
253.4 °F/123 °C
276.8 °F/136 °C
25.8 °F/126 °C
350.6 °F/177 °C
359.6 °F/182 °C
Polycarbonate Diffuser
149 °F/65 °C
195.8 °F/91 °C
242.6 °F/117 °C
235.4 °F/113 °C
267.8 °F/131 °C
249.8 °F/121 °C
–
–
Time Before Opening
in Inches/Millimeters
1.97/50
0.99/25
0.59/15
0.59/15
0.59/15
1.18/30
1.18/30
1.18/30
Lamp and Power
70 W Sodium
150 W Sodium
150 W Metal Halide
250 W Sodium
250 W Metal Halide
250 W Mercury
400 W Sodium
400 W Metal Halide
400 W Mercury
1000 W Sodium
1000 W Metal Halide
T Rating for Ta = 104 °F/40 °C
T4
T4
T4
T3
T3
T3
T3
T2
T2
T3
T3
T Rating for Ta = 122 °F/50 °C
T4
T4
T4
T3
T3
T3
T3 (Cable T ° = 188.6 °F/87 °C)
T2 (Cable T ° = 183.2 °F/84 °C)
T2 (Cable T ° = 183.2 °F/84 °C)
T3
T3
T Rating for Ta = 131 °F/55 °C
T4
T4
T4
T3 (Cable T ° = 179.6 °F/82 °C)
T3
T3 (Cable T ° = 177.8 °F/81 °C)
T2 (Cable T ° = 197.6 °F/92 °C)
T2 (Cable T ° = 192.2 °F/89 °C)
T2 (Cable T ° = 192.2 °F/89 °C)
–
–
Lamp and Power
70 W Sodium
150 W Sodium
150 W Lodure
250 W Sodium
250 W Lodure
250 W Mercury
400 W Sodium
400 W Lodure
400 W Mercury
T Rating for Ta = 104 °F/40 °C
242.6 °F/117 °C
2.66 °F/130 °C
262.4 °F/128 °C
320 °F/160 °C
47 °F/175 °C
357.8 °F/181 °C
388.4 °F/198 °C
442.4 °F/228 °C
440.6 °F/227 °C
368.6 °F/187 °C
(for Ta = 122 °F/50 °C)
377.6 °F/192 °C
(for Ta = 122 °F/50 °C)
T Rating for Ta = 122 °F/50 °C
–
–
–
–
–
–
T3 (Cable T ° = 188.6 °F/87 °C)
T2 (Cable T ° = 183.2 °F/84 °C)
T2 (Cable T ° = 183.2 °F/84 °C)
T Rating for Ta = 131 °F/55 °C
–
–
–
T3 (Cable T ° = 179.6 °F/82 °C)
–
T3 (Cable T ° = 177.8 °F/81 °C)
T2 (Cable T ° = 197.6 °F/92 °C)
T2 (Cable T ° = 192.2 °F/89 °C)
T2 (Cable T ° = 192.2 °F/89 °C)
Cable T ° = 194 °F/90 °C
–
Cable T ° = 194 °F/90 °C
–
Zone 2 (Gas)
Body Size: M
LIGHTING: ENCLOSED AND GASKETED — FLOODLIGHT
Body Size: L
Zone 22 (Dust)
Body Size: M
1000 W Sodium
Body Size: L
Lighting
1000 W Lodure
1168
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© January 2011
PN Series Floodlights – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Zone 2, 21 and 22
II 2 D II 3 GD
ATEX / IECEx
IP66 - IK07/08
Type
Weight (lbs/kg)
Volume (in3/dm3)
Permissible lamps (not
supplied)
Body Size
Catalog Number
Standard with Lamp Glass Sealed on Frame
70 W HP Sodium
26.7/12.1
3814/62.5
Ovoid/Tubular
Medium
PNM1L70AGXJ
150 W HP Sodium
28.4/12.9
3814/62.5
Ovoid/Tubular
Medium
PNM1L15AGXJ
250 W HP Sodium
31.5/14.3
3814/62.5
Ovoid/Tubular
Medium
PNM1L25AGXJ
400 W HP Sodium
35.3/16.0
3814/62.5
Ovoid/Tubular
Medium
PNM1L40AGXJ
400 W HP Sodium
–
–
Ovoid/Tubular
Large
PNL1L40AGXJ
150 W Metal Halide
28.4/12.9
3814/62.5
Ovoid/Tubular
Medium
PNM1H15AGXJ
250 W Metal Halide
31.5/14.3
3814/62.5
Ovoid/Tubular
Medium
PNM1H25AGXJ
400 W Metal Halide
35.3/16.0
3814/62.5
Tubular
Medium
PNM1H40AGXJ
–
–
Ovoid/Tubular
Large
PNL1H40AGXJ
250 W Mercury Vapor
28.4/12.9
3814/62.5
Ovoid
Medium
PNM1M25AGXJ
400 W Mercury Vapor
30.4/13.8
3814/62.5
Ovoid/Tubular
Medium
PNM1M40AGXJ
400 W Metal Halide
With External Polycarbonate Weatherproof Protection
70 W HP Sodium
29.1/13.2
3814/62.5
Ovoid/Tubular
Medium
PNM1L70APXJ
150 W HP Sodium
30.9/14.0
3814/62.5
Ovoid/Tubular
Medium
PNM1L15APXJ
250 W HP Sodium
34.0/15.4
3814/62.5
Ovoid/Tubular
Medium
PNM1L25APXJ
400 W HP Sodium
–
–
Ovoid/Tubular
Large
PNL1L40APXJ
150 W Metal Halide
30.9/14.0
3814/62.5
Ovoid/Tubular
Medium
PNM1H15APXJ
250 W Metal Halide
34.0/15.4
3814/62.5
Ovoid/Tubular
Medium
PNM1H25APXJ
400 W Metal Halide
–
–
Ovoid/Tubular
Large
PNL1H40APXJ
30.9/14.0
3814/62.5
Ovoid
Medium
PNM1M25APXJ
250 W Mercury Vapor
Description
Catalog Number
Fall Prevention Kit
(3.94"/1.2 m stainless steel chain) for M20 cable entry
FESCM20
Slipfitter Adapter — fits medium body.
Slip-fits 1-1/2” or 2” pipe size poletop tenons. Includes floodlight yoke bolts,
3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate
sealed, with cast aluminum cap. Assembly has architectural bronze polyester
finish.
GSF20
Slipfitter Adapter — fits large body.
Slip-fits 2” or 2-1/2” poletop tenons. Includes floodlight yoke bolts, 3 locking
bolts, and cord grip. Malleable iron, zinc plated, chromate sealed, with
architectural bronze polyester finish.
GAM8SF
LIGHTING: ENCLOSED AND GASKETED — FLOODLIGHT
Accessories
Lighting
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© November 2011
1169
PN Series Floodlight Dimensions and Photometric Data – Zone 2, 21 and 22
Metal Halide, Sodium and Mercury
Listed for simultaneous exposure to combustible dusts and flammable gases or vapors.
Dimensions
Size M
Size L
7.76”/197 mm
7.36”/
197 mm
22.17”/563.0 mm
5.12”/
130.0 mm
5.12”/
130.0 mm
2.17”/
55.0 mm
3.50”/
89 mm
60
(3) Mounting Holes
0.55”/14.0 mm
3.50”/
89.0 mm
90
2.78”/
70.5 mm
2.01”/
51.0 mm
(3) Mounting Holes
0.54”/13.8 mm
3.62”/
92.0 mm
90
3.50”/
89.0 mm
5.55”/
141.0 mm
60
5.55”/
141.0 mm
16.14”/410.0 mm
2.01”/
51.0 mm
11.22”/
285.0 mm
13.50”/
343.0 mm
19.68”/500.0 mm
22.17”/563.0 mm
16.92”/460.0 mm
30
0
30
3.62”/
92.0 mm
Photometric Data
Lamps: 70 W High Pressure Sodium
Polar curves for a 1000 lm flux, according to NF C 71-120
Luminaire symbol according to NF C 71-121
(0-180)
(90-270)
0
487
487
5
439
461
10
416
387
15
372
324
20
208
290
25
129
294
30
116
319
35
111
318
40
101
289
45
86
193
50
70
150
55
84
141
60
62
132
65
22
88
70
9
15
Total Luminaire Efficiency = 74.6%
Longitudinal
Transverse
Lighting
LIGHTING: ENCLOSED AND GASKETED — FLOODLIGHT
Candelas
Degrees
1170
Visit our website at www.appletonelec.com or contact us at (800) 621-1506.
© January 2011
Download