PN Series Floodlights – Zone 2, 21 and 22 Metal Halide, Sodium and Mercury Listed for simultaneous exposure to gas, combustible dusts and flammable gases or vapors. Zone 2, 21 and 22 II 2 D II 3 GD ATEX / IECEx IP66 - IK07/08 Applications • Powerful, efficient floodlights for large areas such as industrial complexes and ship loading areas. • Rated for use in hazardous areas. Features • Highly efficient, integrally ballasted floodlight. Has compact, lightweight, yet rugged die cast aluminum construction. • Simple installation and maintenance. • Integral ballast; 230/240 V, 50 Hz. • One-piece lens cover. • Heavy duty, high temperature silicone rubber gasket, firmly seated. • Socket: E40 (E27 for 70 W HPS version). • Reflectors: double segment compound parabolic with finish for maximum efficiency. • Mounting: yoke mount. Standard Materials • Ballast housing and lens door: copperfree (4/10 of 1% max.) aluminum • Gasket: silicone rubber • Socket: heavy duty porcelain with heavy gauge brass shell • Reflector: finished aluminum • Yoke mount: zinc plated steel • Bolts: stainless steel Standard Finishes • Ballast housing, lens cover, yoke and pole mount: architectural bronze polyester • Socket: nickel-plated • Size M — Certification Type PJn — Gas: Zone 2 Conforming to ATEX 94/9/CE: CE 3G ATEX/IEC Protection: Ex nR II T Rating: T2 to T4 Ambient Temperature: 104 °F to 131 °F/40 °C to 55 °C — Dust: Zone 22 Conforming to ATEX 94/9/CE: CE II 3 D ATEX/IEC Protection: Ex tD A22 Surface Temperature: T243 °F/T117 °C to 442 °F/T228 °C — Gas, Zone 2 and Dust, Zone 22 Ambient Temperature: 104 °F to 131 °F / 40 °C to 55 °C ATEX Certificate: LCIE 08 ATEX 6035X IEC Certificate: IECEx LCI 04.0015 Other Certifications: GOST Impact Resistance (shock): IK07 — Dust: Zone 21 Conforming to ATEX 94/9/CE: CE I2D ATEX/IEC Protection: Ex tD A21 Surface Temperature: T149 °F to T277 °F/T65 °C to T136 °C Ambient Temperature: -4 °F to 104 °F/-20 °C to 40 °C ATEX Certificate: LCIE 02 ATEX 6246X Impact Resistance (shock): IK07 with glass diffuser, IK08 with polycarbonate diffuser — CE Declaration of Conformity: 50251 — Index of Protection (solid and liquid): IP66 Lighting LIGHTING: ENCLOSED AND GASKETED — FLOODLIGHT Certifications and Compliances • Size G — Certification Type PJn — Gas: Zone 2 Conforming to ATEX 94/9/CE: CE 3G ATEX/IEC Protection: Ex nR II T Rating: T3 — Dust: Zone 22 Conforming to ATEX 94/9/CE: CE II 3 D ATEX/IEC Protection: Ex tD A22 Surface Temperature: T369 °F to T378 °F/T187 °C to T192 °C — Gas, Zone 2 and Dust, Zone 22 Ambient Temperature: 104 °F to 131 °F/40 °C to 55 °C CE Declaration of Conformity: 50215 ATEX Certificate: LCIE 08 ATEX 6035X IEC Certificate: IECEx LCI 04.0015 Other Certifications: GOST Impact Resistance (shock): IK07 — Dust: Zone 21 II 2 D Conforming to ATEX 94/9/CE: CE 008 ATEX/IEC Protection: Ex tD A21 Surface Temperature: T250°F to T360°F / T121°C to T182°C Ambient Temperature: -4°F to 104°F / -20°C to 40°C CE Declaration of Conformity: 50274 ATEX Certificate: LCIE 02 ATEX 6246X Impact Resistance (shock): IK07 with glass diffuser, IK08 with polycarbonate diffuser — Index of Protection (solid and liquid): IP66 • Ex Standards: EN/IEC 60079-0, 60079-15, 61241-0, 61241-1 • Product Standards: EN/IEC 60598-1 • EMC Standards: EN/IEC 55015, 61547 • Other Standards: EN/IEC 60529 (IP) 1166 Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © January 2011 PN Series Floodlights – Zone 2, 21 and 22 Metal Halide, Sodium and Mercury Listed for simultaneous exposure to gas, combustible dusts and flammable gases or vapors. Zone 2, 21 and 22 II 2 D II 3 GD ATEX / IECEx IP66 - IK07/08 Order using catalog numbering guide below or select catalog number from tables on following pages. Catalog Numbering Guide For PN Series Luminaires PN P Series: PN - PN Series Zone 2, 21 & 22 ATEX / IEC Certified Body Size: P - Small M - Medium L - Large 1 H Mounting: 1 - Yoke 5 - Pole Slip-fit 70 Wattage: 70 - 70 W 15 - 150 W 25 - 250 W 40 - 400 W ① 99 - 1000 W ① Lamp Type: H - Metal Halide L - Sodium M - Mercury A G MT Diffuser: G - Glass P - Polycarbonate ② Entry Size: A - M20 F Options: S - Stainless Steel Housing Options: XA - 220 Vac 50 Hz (Magnetic Ballast) XJ - 230/240 Vac 50 Hz (Magnetic Ballast) LIGHTING: ENCLOSED AND GASKETED — FLOODLIGHT Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © January 2011 Lighting ① 400 W Zones 21-22 and 1000 W Zones 2-22 only with large body (suffix -G). ② Zone 2-22 doesn’t exist with polycarbonate diffuser. 1167 PN Series Floodlight T Ratings – Zone 2, 21 and 22 Metal Halide, Sodium and Mercury Listed for simultaneous exposure to gas, combustible dusts and flammable gases or vapors. Zone 2, 21 and 22 II 2 D II 3 GD ATEX / IECEx IP66 - IK07/08 Zone 21 (Dust) Dust Surface Temperatures for Ta = 104 °F/40 °C Operating Position Body Size: M Body Size: L Lamp and Power 70 W Sodium 150 W Sodium 250 W Sodium 250 W Metal Halide 250 W Mercury 400 W Sodium 1000 W Sodium 1000 W Metal Halide Glass Diffuser 167 °F/75 °C 213.8 °F/101 °C 260.6 °F/127 °C 253.4 °F/123 °C 276.8 °F/136 °C 25.8 °F/126 °C 350.6 °F/177 °C 359.6 °F/182 °C Polycarbonate Diffuser 149 °F/65 °C 195.8 °F/91 °C 242.6 °F/117 °C 235.4 °F/113 °C 267.8 °F/131 °C 249.8 °F/121 °C – – Time Before Opening in Inches/Millimeters 1.97/50 0.99/25 0.59/15 0.59/15 0.59/15 1.18/30 1.18/30 1.18/30 Lamp and Power 70 W Sodium 150 W Sodium 150 W Metal Halide 250 W Sodium 250 W Metal Halide 250 W Mercury 400 W Sodium 400 W Metal Halide 400 W Mercury 1000 W Sodium 1000 W Metal Halide T Rating for Ta = 104 °F/40 °C T4 T4 T4 T3 T3 T3 T3 T2 T2 T3 T3 T Rating for Ta = 122 °F/50 °C T4 T4 T4 T3 T3 T3 T3 (Cable T ° = 188.6 °F/87 °C) T2 (Cable T ° = 183.2 °F/84 °C) T2 (Cable T ° = 183.2 °F/84 °C) T3 T3 T Rating for Ta = 131 °F/55 °C T4 T4 T4 T3 (Cable T ° = 179.6 °F/82 °C) T3 T3 (Cable T ° = 177.8 °F/81 °C) T2 (Cable T ° = 197.6 °F/92 °C) T2 (Cable T ° = 192.2 °F/89 °C) T2 (Cable T ° = 192.2 °F/89 °C) – – Lamp and Power 70 W Sodium 150 W Sodium 150 W Lodure 250 W Sodium 250 W Lodure 250 W Mercury 400 W Sodium 400 W Lodure 400 W Mercury T Rating for Ta = 104 °F/40 °C 242.6 °F/117 °C 2.66 °F/130 °C 262.4 °F/128 °C 320 °F/160 °C 47 °F/175 °C 357.8 °F/181 °C 388.4 °F/198 °C 442.4 °F/228 °C 440.6 °F/227 °C 368.6 °F/187 °C (for Ta = 122 °F/50 °C) 377.6 °F/192 °C (for Ta = 122 °F/50 °C) T Rating for Ta = 122 °F/50 °C – – – – – – T3 (Cable T ° = 188.6 °F/87 °C) T2 (Cable T ° = 183.2 °F/84 °C) T2 (Cable T ° = 183.2 °F/84 °C) T Rating for Ta = 131 °F/55 °C – – – T3 (Cable T ° = 179.6 °F/82 °C) – T3 (Cable T ° = 177.8 °F/81 °C) T2 (Cable T ° = 197.6 °F/92 °C) T2 (Cable T ° = 192.2 °F/89 °C) T2 (Cable T ° = 192.2 °F/89 °C) Cable T ° = 194 °F/90 °C – Cable T ° = 194 °F/90 °C – Zone 2 (Gas) Body Size: M LIGHTING: ENCLOSED AND GASKETED — FLOODLIGHT Body Size: L Zone 22 (Dust) Body Size: M 1000 W Sodium Body Size: L Lighting 1000 W Lodure 1168 Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © January 2011 PN Series Floodlights – Zone 2, 21 and 22 Metal Halide, Sodium and Mercury Listed for simultaneous exposure to combustible dusts and flammable gases or vapors. Zone 2, 21 and 22 II 2 D II 3 GD ATEX / IECEx IP66 - IK07/08 Type Weight (lbs/kg) Volume (in3/dm3) Permissible lamps (not supplied) Body Size Catalog Number Standard with Lamp Glass Sealed on Frame 70 W HP Sodium 26.7/12.1 3814/62.5 Ovoid/Tubular Medium PNM1L70AGXJ 150 W HP Sodium 28.4/12.9 3814/62.5 Ovoid/Tubular Medium PNM1L15AGXJ 250 W HP Sodium 31.5/14.3 3814/62.5 Ovoid/Tubular Medium PNM1L25AGXJ 400 W HP Sodium 35.3/16.0 3814/62.5 Ovoid/Tubular Medium PNM1L40AGXJ 400 W HP Sodium – – Ovoid/Tubular Large PNL1L40AGXJ 150 W Metal Halide 28.4/12.9 3814/62.5 Ovoid/Tubular Medium PNM1H15AGXJ 250 W Metal Halide 31.5/14.3 3814/62.5 Ovoid/Tubular Medium PNM1H25AGXJ 400 W Metal Halide 35.3/16.0 3814/62.5 Tubular Medium PNM1H40AGXJ – – Ovoid/Tubular Large PNL1H40AGXJ 250 W Mercury Vapor 28.4/12.9 3814/62.5 Ovoid Medium PNM1M25AGXJ 400 W Mercury Vapor 30.4/13.8 3814/62.5 Ovoid/Tubular Medium PNM1M40AGXJ 400 W Metal Halide With External Polycarbonate Weatherproof Protection 70 W HP Sodium 29.1/13.2 3814/62.5 Ovoid/Tubular Medium PNM1L70APXJ 150 W HP Sodium 30.9/14.0 3814/62.5 Ovoid/Tubular Medium PNM1L15APXJ 250 W HP Sodium 34.0/15.4 3814/62.5 Ovoid/Tubular Medium PNM1L25APXJ 400 W HP Sodium – – Ovoid/Tubular Large PNL1L40APXJ 150 W Metal Halide 30.9/14.0 3814/62.5 Ovoid/Tubular Medium PNM1H15APXJ 250 W Metal Halide 34.0/15.4 3814/62.5 Ovoid/Tubular Medium PNM1H25APXJ 400 W Metal Halide – – Ovoid/Tubular Large PNL1H40APXJ 30.9/14.0 3814/62.5 Ovoid Medium PNM1M25APXJ 250 W Mercury Vapor Description Catalog Number Fall Prevention Kit (3.94"/1.2 m stainless steel chain) for M20 cable entry FESCM20 Slipfitter Adapter — fits medium body. Slip-fits 1-1/2” or 2” pipe size poletop tenons. Includes floodlight yoke bolts, 3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate sealed, with cast aluminum cap. Assembly has architectural bronze polyester finish. GSF20 Slipfitter Adapter — fits large body. Slip-fits 2” or 2-1/2” poletop tenons. Includes floodlight yoke bolts, 3 locking bolts, and cord grip. Malleable iron, zinc plated, chromate sealed, with architectural bronze polyester finish. GAM8SF LIGHTING: ENCLOSED AND GASKETED — FLOODLIGHT Accessories Lighting Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © November 2011 1169 PN Series Floodlight Dimensions and Photometric Data – Zone 2, 21 and 22 Metal Halide, Sodium and Mercury Listed for simultaneous exposure to combustible dusts and flammable gases or vapors. Dimensions Size M Size L 7.76”/197 mm 7.36”/ 197 mm 22.17”/563.0 mm 5.12”/ 130.0 mm 5.12”/ 130.0 mm 2.17”/ 55.0 mm 3.50”/ 89 mm 60 (3) Mounting Holes 0.55”/14.0 mm 3.50”/ 89.0 mm 90 2.78”/ 70.5 mm 2.01”/ 51.0 mm (3) Mounting Holes 0.54”/13.8 mm 3.62”/ 92.0 mm 90 3.50”/ 89.0 mm 5.55”/ 141.0 mm 60 5.55”/ 141.0 mm 16.14”/410.0 mm 2.01”/ 51.0 mm 11.22”/ 285.0 mm 13.50”/ 343.0 mm 19.68”/500.0 mm 22.17”/563.0 mm 16.92”/460.0 mm 30 0 30 3.62”/ 92.0 mm Photometric Data Lamps: 70 W High Pressure Sodium Polar curves for a 1000 lm flux, according to NF C 71-120 Luminaire symbol according to NF C 71-121 (0-180) (90-270) 0 487 487 5 439 461 10 416 387 15 372 324 20 208 290 25 129 294 30 116 319 35 111 318 40 101 289 45 86 193 50 70 150 55 84 141 60 62 132 65 22 88 70 9 15 Total Luminaire Efficiency = 74.6% Longitudinal Transverse Lighting LIGHTING: ENCLOSED AND GASKETED — FLOODLIGHT Candelas Degrees 1170 Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © January 2011