Prop-Box HYDAC Fluidtechnik GmbH 1 1. Area of application The Prop-Box is a simple tool for the commissioning of proportional valves and continuously adjustable valves with onboard-electronics and central connector according to DIN 43563 (6 pole + PE). In the course of development, we placed particular emphasis on simple operability and comprehensive protective circuits to prevent damages to the valves to be tested the Prop-Box. The Prop-Box supports service technicians specifically with the following functions: • Supply voltage control (reverse polarity and voltage level) • Optional 4..20mA, 0..10V, +/-10V setpoint selection (optional enable signal on Pin C) • Setpoint selection via potentiometer or connected control • Convenient digital display of setpoint and actual value • Inbuilt protective function in case of erroneous connection 2. Note This instruction manual and other information issued by HYDAC Fluidtechnik GmbH and its contract partners provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance endurance, maintenance, safety and warning requirements of the application are met. The user must thoroughly analyse all aspects of the application, follow applicable industry standards, and follow the information concerning the product provided by HYDAC Fluidtechnik GmbH. Insofar HYDAC Fluidtechnik GmbH or its authorized dealers deliver components or system options based on technical data or specifications that were provided by the user, the user is responsible for ensuring the suitability and sufficiency of these technical data and specifications for all applications and reasonably foreseeable usages of the components or systems. No liability is assumed for damages that were caused by misuse. HYDAC Fluidtechnik GmbH Justus-v.-Liebig Str., 66280 Sulzbach/Saar Tel +49 (0)6897 509 01 www.hydac.com info@hydac.com Subject to technical changes and typographical errors. © 2016 HYDAC Fluidtechnik GmbH 2 3. Technical data Prop-Box Supply voltage: Power input: Input fuse: Required main supply fuse: Protection class: Setpoint signals: Actual value signals: Shunt in the current loop: Load resistor can be activated at actual current loop: Option enable signal: Display: Display tolerance Ambient conditions: Weight: Dimensions: 24V DC (18 – 30V DC) 40W (max. 60W) 2.5A PTC max. 16A IP40 0-10V; -10..+10V; 4..20mA 0-10V; -10..+10V; 4..20mA 10Ω 220Ω (LOPP RES 220Ω) 24V DC internal resistor 2kΩ 3½ Display digits, 1digit corresponds to 0.01V / 0.1mA ± 3% from measurement range end value 0…40°C 0.35kg 150 x 90 x 60mm without cable Required impedance/load resistor at the proportional valve or control valve with internal setpoint selection: > 2kΩ Setpoint selection 0..10V, -10..+10V Setpoint selection 4..20mA 100 - 500Ω Electric impedance/load resistor Prop-Box for measurement feedback signal, with internal setpoint selection: Actual value 0..10V, -10..+10V 300kΩ Actual value 4..20mA 220Ω (connectable) + 10Ω (Shunt) Electric impedance/load resistor of the Prop-Box with external setpoint selection: 300kΩ parallel to the valve Setpoint selection 0..10V, -10..+10V Setpoint selection 4...20mA 10Ω (shunt) in series to the valve Electric impedance/load resistor of the Prop-Box for measurement feedback signal, with external setpoint selection: Actual value 0..10V, -10..+10V 300kΩ parallel to the valve Actual value 4..20mA 10Ω (shunt) in series to the source or 220 Ω (connected) + 10Ω (shunt) HYDAC Fluidtechnik GmbH 3 4. Front view Prop-Box HYDAC Fluidtechnik GmbH 4 4.1. Description of the operating elements 1 „Input plug 1“ housing bulkhead mounting male connector with flange 6+PE Hirschmann CM02E14S-61P / Art. No.: 932455-100 2 „Output plug 2“ Connecting line for continuously adjustable valves 2 m cable with socket 6+PE Hirschmann CM06EA14S-61S / Art. No.: 932460-100 3 LED GREEN LED RED Supply voltage polarity OK Supply voltage not OK FAULT 4 LED GRÜN Supply voltage valve >24V DC ±5% 5 0..10V -10..+10V EXTERN 4..20mA 6 SET 7 Display SET 8 FEEDBACK 9 Display FEEDBACK 10 OPERATING MODE SELECTION SWITCH Setpoint setting via potentiometer 0..10V Setpoint setting via potentiometer -10..+10V Setpoint setting EXTERNAL via input plug 1 Setpoint setting via potentiometer 4..20mA V mA Setpoint display voltage in V Setpoint display current in mA Digital setpoint display 3½-digit (V or mA) ± 3% (from the upper range value) V mA Actual value display voltage in V Actual value display current in mA Digital actual value display 3½-digit (V or mA) ) ±3% (from the upper range value) Connection load resistor Prop-Box for measurement feedback-signal, with internal setpoint setting (pressure switch, latching) Not pressed: no load resistor in the actual value signal Pressed: 220 Ω load resistor in the actual value signal In valves with current signal on the actual value the value cannot be read without connecting a load resistor. A load in the Prop-Box can be connected via the pressure switch „LOOP RES 220Ω“. This automatically disconnects the actual value signal from the input plug 1. 11 ENABLE 24V ON C Optional enable signal (24 V) on Pin C. Reference potential for the feedback-signal is the potential of Pin B or E. The enable signal is limited to 12mA (2kΩ resistance). 12 0V/12mA POT Fixed setpoint setting of the valve to 0V or 12mA Setpoint setting valve via potentiometer 13 POT SET Potentiometer for analogous setpoint setting HYDAC Fluidtechnik GmbH 5 PTC-semiconductor fuse: If the fuse is triggered (= displays failed), separate voltage supply from the power, eliminate cause and reactivate after approximately 30 seconds. Remarks: • If the ACTUAL voltage value follows the SETPOINT value in one divider, check whether the „LOOP RES 220Ω“ pressure switch is pressed/active. • If the value 0 is indicated on the FEEDBACK display during current measurement, check whether the current loops run via the load resistor is closed. • Supply voltages >30V DC may lead to destruction of the protective circuit „interference suppression diode“ (short circuit). 4.2. Functional description 1. Select OPERATION MODE for set point (EXTERN for external set point via input connector 1, -10..+10V, 0..+10V, 4..20mA via POTentiometer) 2. Select poper mode for SET point display (V or mA) 3. Using a valve with feedback, select proper mode for FEEDBACK display (V or mA) 4. When using the Prop-Box without an external loop resistance for mA FEEDBACK connected via input connector 1 in FEEDBACK mode mA, active internal loop resistor by pushing the button LOOP RES 220Ω. Else check it is not pressed. Note: Activating the internal LOOP RESistance 220Ω disconnects the feedback signal from the input connector 1 5. Disable switch 24V ON C (turn OFF) 6. Set POTentiometer SETting to 5V/0V/12mA (safe value) 7. Connect input connector 1 to Prop-Box 8. Check POLARITY OK and voltage >24V DC 9. Connect valve via output connector 2 to Prop-Box 10. Test valve with EXTERNal setpoint in operation mode EXTERN or test valve with internal setpoint V or mA via POTentiometer when setting the switch to POT (If the valve requires a 24 V DC enable signal on pin C, activate switch 24V ON C) HYDAC Fluidtechnik GmbH 6 4.3. Interface description, symbol diagram A……24V DC (18-30V DC) B……GND C……FEEDBACK REF/ENABLE 24V DC D……SET E……SET REF F……FEEDBACK PE….EARTH Attention: When testing valves with an enable signal on PIN C (switch „24V ON C“) please consider that a LOW signal (<3V DC) is connected to PIN C on the supply side of the Prop-Box. The LOW signal on the supply side of the Prop-Box is required for correct switching OFF the valve with the enable signal. Nonobservance may cause an unintentional enable signal on PIN C independent of the position from the switch “24V ON C”. This may also cause unexpected and dangerous movements on your machine. In case of testing valves with a required signal on PIN C (switch “24V ON C”) the load resistance “LOOP RES 220 Ω“ has to be switched off. A non-observance may cause an unintentional enable signal on PIN C, depending on the actual valve signal level (signal on PIN F). This may also cause unexpected and dangerous movements on your machine. HYDAC Fluidtechnik GmbH 7 5. Accessories 5.1. Prop-Box-Supply For control of the continuously adjustable solenoid valve via the internal setpoint setting, the supply for the continuously adjustable solenoid valve can be realized via the plug-in power supply „Prop-Box-Supply“. 5.1.1 Technical data Input voltage: Output voltage: Output current: Ripple and interference voltage: Required main supply fuse: Cable: Ambient conditions: Efficiency: Weight: Dimensions: 90 – 264V; 47 – 63Hz 24V DC 2.5A 240mV pk-pk max. 16A 1.5 m with line socket 6+PE according to DIN 43563 0…40°C 87 - 92% 0.3kg 103 x 66 x 40mm without cable AC Input Clips (sold separately) RPA…US RPB…Brazil RPE…China RPE…Europe RPH…Korea RPI…India RPK…UK RPN…Argentina RPS…Australia RPX…IEC320 C8 HYDAC Fluidtechnik GmbH 8 5.2. Prop-Box Adapter HYDAC Fluidtechnik GmbH 9 5.2.1. Description of Prop-Box-Adapter operating elements 1 „Input plug 1“ housing bulkhead mounting male connector with flange 6+PE Hirschmann CM02E14S-61P / Art. No.: 932455-100 2 „Output plug 2“ Connecting line for continuously adjustable valves 2 m cable with socket 6+PE Hirschmann CM06EA14S-61S / Art. No.: 932460-100 3 24V DC Power supply 24V DC (0 – 30V DC) 4 GND Power supply GND 5 FEEDBACK REF / ENABLE 24V DC Actual value reference (GND) / Enable signal 24V DC 6 SET Setpoint 7 SET REF Setpoint reference (GND) 8 FEEDBACK Actual value 9 PE Potential ground All signals can be picked up by means of the Prop-Box-Adapter via 4mm-sockets. 5.2.2. Technical data Supply voltage: Required main supply fuse: Connection: Protection class: Ambient conditions: Weight: Dimensions: HYDAC Fluidtechnik GmbH 0 – 30V DC 6A housing bulkhead mounting male connector according to DIN 43563 IP40 0…40°C 0.35kg 150 x 90 x 60mm (without cable) 10