6 © Siemens AG 2011 SITOP 1-phase and 2-phase 24 V DC, 6 A 6/2 6/2 6/4 SITOP PSA100E 6 A PSU100D 6.2 A Ordering data and additional information Export regulations AL and ECCN see page 17/9 Siemens KT 10.1 · 2012 © Siemens AG 2011 SITOP 1-phase and 2-phase 24 V DC Output current 6 A ■ Overview NEW Product Special design PSA100E Special design PSU100D Power supply, type 6A 6.2 A Order No. 6EP1 233-1AA00 6EP1 333-1LD00 The power supply is optimally designed for standard requirements in the industrial environment; rugged metal enclosure; flexible mounting either on standard rails or directly on a wall; removable terminals. The low-cost power supply in flat aluminum housing can be screwed directly on a wall in various mounting positions; with wide-range input for global use. Special design PSA100E Special design PSU100D Rated voltage value Vin rated 1-phase AC 230 V AC Voltage range 187 ... 264 V 1-phase AC 100-240 V AC Wide-range input 85 ... 264 V Overvoltage resistance Mains buffering at Iout rated Rated line frequency value; range – > 10 ms 50/60 Hz; 47 ... 63 Hz > 15 ms at Vin = 115/230 V 50/60 Hz; 47 ... 63 Hz Rated current Iin rated Switch-on current limit (+25 °C) I2t 1.4 A < 35 A < 1.2 A2s 3.1-2.0 A < 75 A < 6.5 A2s Built-in incoming fuse Recommended miniature circuit breaker (IEC 898) in the mains power input Internal 10 A or higher, characteristic C Internal 10 A or higher, characteristic C or 16 A, characteristic B Rated voltage Vout rated Controlled, isolated DC voltage 24 V DC Controlled, isolated DC voltage 24 V DC Total tolerance • Static line compensation • Static load compensation ±3 % Approx. 0.1 % Approx. 0.5 % ±2 % Approx. 0.5 % Approx. 1 % Residual ripple Spikes (bandwidth: 20 MHz) < 150 mVpp < 250 mVpp < 100 mVpp < 100 mVpp Adjustment range Status display On/off behavior 23 ... 26 V Green LED for 24 V OK Overshoot of Vout < 5 % 22.0 ... 28.0 V Green LED for 24 V OK Overshoot of Vout < 2 % Startup delay / voltage rise Rated current value Iout rated < 0.3 s/< 500 ms < 1 s/< 30 ms 6A 6.2 A Current range • Up to + 60 °C • Derating 0 ... 6 A (up to +45 °C) 0 ... 3 A (up to +70 °C) 0 ... 6.2 A (up to +50 °C) 0 ... 3.1 A (up to +70 °C) Yes, 2 units Yes, 2 units The product families are highlighted in the same color. For an explanation of the product families, see chapter 1, pages 1/8 through 1/12. 6 ■ Technical specifications Product Input Output Dynamic overcurrent on • Power-up on short circuit • Short circuit during operation Parallel switching for enhanced performance 6/2 Siemens KT 10.1 · 2012 © Siemens AG 2011 SITOP 1-phase and 2-phase 24 V DC Output current 6 A ■ Technical specifications (continued) Product Power supply, type Order No. Efficiency Efficiency at Vout rated, Iout rated Power loss at Vout rated, Iout rated Closed-loop control Dyn. mains compensation (Vin rated ± 15 %) Dynamic load smoothing (Iout: 50/100/50 %) Load step settling time • 50 at 100 % • 100 at 50 % Protection and monitoring Output overvoltage protection Current limitation Special design PSA100E 6A 6EP1 233-1AA00 Special design PSU100D 6.2 A 6EP1 333-1LD00 Approx. 87 % Approx. 22 W Approx. 86 % Approx. 24 W <0.3 % Vout Typ. ± 0.5 % Vout Typ. ± 2.0 % Vout Typ. ± 5.0 % Vout (0 to 100 %) Typ. 0.1 ms Typ. 0.1 ms < 35 V Typ. 6.6 A Short-circuit protection Electronic shutdown, automatic restart Sustained short-circuit current rms < 3.6 A value Overload/short-circuit indicator – Safety Primary/secondary isolation Yes, SELV output voltage Vout according to EN 60950-1 and EN 50178 Protection class Class I Leakage current < 3.5 mA (typ. 0.8 mA) Safety test Yes; CB Scheme CE mark Yes UL/cUL (CSA) approval cULus-Listed (UL 508, CSA C22.2 No.107.1), File E197259 Explosion protection FM approval Marine approval Degree of protection (EN 60529) EMC Emitted interference Supply harmonics limitation Noise immunity Operating data Ambient temperature range Transport/storage temperature range Humidity class Mechanics Connections • Supply input L, N, PE • Output + • Output – Dimensions (W x H x D) in mm Weight, approx. Installation 6 < 35 V 7.4 A Electronic shutdown, automatic restart 16 A – – – – IP20 Yes, safety extra low output voltage Vout according to EN 60950-1 Class I < 3.5 mA (typ. 1 mA) Yes; CB Scheme in preparation Yes cULus-Listed (UL 508, CSA C22.2 No.107.1) in preparation; cURus (UL 60950-1, CSA C22.2 No. 60950-1) in preparation – – – IP20 EN 55022 Class B – EN 61000-6-2 EN 55022 Class B – EN 61000-6-2 -10 ... +70 °C with natural convection -10 ... +70 °C with natural convection -40 ... +85 °C -25 ... +85 °C Climate class 3K3 according to EN 60721, no condensation Removable screw terminal for 1 × 0.5 ... 2.5 mm2 each Removable screw terminal for 1 × 0.5 ... 2.5 mm2 Removable screw terminal for 1 × 0.5 ... 2.5 mm2 52 × 170 × 110 0.9 kg Snaps onto DIN rail EN 60715 35x7.5/15. Wall mounting One screw-type terminal each for 0.3 ... 1.3 mm2 solid/finely stranded 2 screw terminals for 0.3 ... 1.3 mm2 2 screw terminals for 0.3 ... 1.3 mm2 97 x 178 x 38 0.55 kg Wall mounting – – Accessories Siemens KT 10.1 · 2012 6/3 © Siemens AG 2011 SITOP 1-phase and 2-phase 24 V DC Output current 6 A ■ Selection and ordering data Product Input Output Voltage Vin rated Voltage Vout rated Current Iout rated Order No. 230 V AC 24 V DC 6A 6EP1 233-1AA00 100-240 V AC 24 V DC 6.2 A 6EP1 333-1LD00 Special design, PSA100E Special design, PSU100D (Planned delivery date: December 2011) NEW 6 ■ Further information Additional information is available in the Internet under: • 2D dimensional drawings, 3D CAD data, circuit diagram macros: www.siemens.com/sitop-cax • Operating instructions: www.siemens.de/sitop-manuals • Find the right product with the SITOP Selection Tool: www.siemens.com/sitop-selection-tool 6/4 Siemens KT 10.1 · 2012 Price