Section J Index

advertisement
Section J Index
PIN & SLEEVE
IEC Configurations, Ratings,
and Catalog Numbering System ......................................................................J1
Product Features
Watertight Devices ........................................................................................J2, J3
Splashproof Devices ...........................................................................................J9
Switched Mechanical Interlocks ........................................................................J14
Watertight Devices - North American Ratings
20A, 125V AC – 3ØY 277/480, 3W, 4W, 5W ......................................................J4
30A, 125V AC – 3ØY 277/480, 3W, 4W, 5W ......................................................J4
60A, 125V AC – 3ØY 347/600, 3W, 4W, 5W ......................................................J4
100A, 250V AC – 3ØY 277/480, 3W, 4W, 5W ....................................................J5
Watertight Devices - International Ratings
16A, 100-130 – 200/346, 240/415, 3W, 4W, 5W.................................................J5
32A, 100-130 – 200/346, 240/415, 3W, 4W, 5W.................................................J5
63A, 200-250 – 200/346, 240/415, 3W, 4W, 5W.................................................J5
125A, 380-415 – 200/346, 240/415, 4W, 5W ......................................................J5
Splashproof Devices - International Ratings
16A, 100-130 – 200/346, 240/415, 3W, 4W, 5W...............................................J10
32A, 100-130 – 200-250, 3W ............................................................................J10
Back Boxes, Closure Caps, Accessories..............................................J12, J13
Switched Mechanical Interlocks
20A, 240V AC 3Ø – 600V AC 3Ø, 4W ..............................................................J15
30A, 120V AC – 277/480V AC 3ØY, 3W, 4W, 5W............................................J15
32A, 380V AC 3Ø 50 Hz, 440V AC 3Ø, 60 Hz, 4W...........................................J15
60A, 120V AC – 347/600V AC 3ØY, 3W, 4W, 5W...........................................J15
100A, 240V AC – 120/208V AC 3ØY, 3W, 4W, 5W.........................................J15
Dimensional Data
Watertight Devices ........................................................................................J6, J7
Splashproof Devices ........................................................................................J10
Back Boxes, Accessories ..........................................................................J12, J13
Switched Mechanical Interlocks ........................................................................J16
Specifications/Materials
Watertight Devices ..............................................................................................J8
Splashproof Devices ........................................................................................J11
Switched Mechanical Interlocks ........................................................................J16
IEC Configurations
Catalog Numbering System
IEC CONFIGURATIONS MAKE
SAFE CONNECTIONS AS EASY
AS CLOCKWORK
Bryant’s Pin & Sleeve line safeguards against
mismating devices of different amperage and
voltage ratings. Conformance with IEC 309-1 and
IEC 309-2 international standards results in a
singly-rated, non-interchangeable configuration for
each amperage/voltage type.
4-POLE 5-WIRE
A housing size has been specified for each
amperage rating. The voltage rating can be
identified by the clock position of the female
grounding contact relative to the housing keyway.
With the keyway always positioned at 6 o’clock, the
female grounding contact is located at a specific
clock position for each voltage rating. For example,
the female grounding contact for a 125V device is
located at the 4 o’clock position. The location of the
corresponding male pin is a mirror image of the
female device and is located at the 8 o’clock
position. In addition, device housings are
color-coded by voltage rating for easy identification
(see clock chart at right).
2-POLE 3-WIRE
3-POLE 4-WIRE
125/250
V AC
11 12 1
10
3ØY
3Ø 250V
120/208V
4
8
7
480
V AC
3ØY 277/
480V
COLOR
5
6
250
V AC
380V 50Hz
440V 60Hz
250
V DC
3
9
3Ø480
V AC
RATED VOLTAGE
2
125
V AC
277
V AC
380/415
V AC
3Ø 600
V AC
3Ø 347/600V
200/346V AC
240/415V AC
100V-130V
200V-250V
380V-480V
277V
125V/250V
500V and above
The housing keyway is always located at the 6 o’clock position
and is clearly visible to the user.
Catalog Numbering System: Receptacles, Plugs, Connectors, and Inlets
4
30
P
7
W
WIRES
AMPERAGE RATING
NORTH
AMERICAN
DEVICE TYPE
CLOCK POSITION
ENVIRONMENTAL
CLASSIFICATION
3
4
5
20
30
60
100
P - Plug
C - Connector
R - Receptacle
B - Inlet
Clock
Position of
Female
Grounding
Contact
W - Watertight
S - Splashproof
INTERNATIONAL
16
32
63
125
Product specifications appearing in the following section are subject to change without notice.
J
1
Product Features
Watertight Pin & Sleeve Plug
Devices conform to IEC 309-1 and 309-2 International Standards for singly-rated,
non-interchangeable configurations for each amperage/ voltage type. Prevents
mismating of devices with different voltages.
IP67
Catalog numbers and ratings are
included on each device.
Gland nut and body have opposing
thread profiles to prevent pull-out
and reduce wear (available
in most ratings).
No exposed metal screws or clamps
on hand-held side promotes safe
handling and prevents snagging.
Neoprene sealing glands
provide watertight seal at cord entry.
Accommodates varying cord diameters
Cord clamp screws fasten
into threaded, plated steel
nuts to prevent strip-out.
Insulated, impact-resistant, toughened
nylon housing protects against
cracking, warping, corrosion, and
chemical abrasion.
Terminals are clearly
marked for easy
identification.
Internal "swing-away" strain
relief clamp assembly simplifies cord/terminal
wiring. Cord clamp is not exposed to abuse or
impact.
460P7W
External housing key on male devices
mates with keyway on female devices
to provide proper alignment and
simplify the connection of devices. The
keyway is always located at the 6
o’clock position and is clearly visible to
the user, helping to prevent the
mismating of devices with different
ratings.
J
2
WATERTIGHT
RECEPTACLE
Specifications are subject to change without notice.
HOUSING KEYWAY
Pins are fabricated from solid
brass for longevity, contact
reliability, and superior
conductivity. Shrouded housing
helps protect pins from
contaminants and abuse.
Product Features
Watertight Pin & Sleeve Connector
Spring-loaded gasketed cover
keeps connectors and receptacles
protected from moisture and
contaminants when disconnected.
Self-adjusting contacts provide accurate
pin insertion. Contact produces
self-cleaning effect as pin is inserted and
withdrawn from sleeve. Clean connection
protects against overheating and burnout.
Contact carrier resists arcing and
heat-buildup under high
temperatures.
Radial rib exterior provides secure
hand grip.
Phase contacts are recessed
in deep insulated chambers
to minimize arcing.
Ground contact in forward position ensures first make,
last break. Neutral contact connects next, then phase
contacts.
Terminal screws are backed
out for easy assembly.
Bryant’s exclusive Kontex-Plus 60A and
100A contact design features a
well-defined contact area and a stainless
steel clip to provide more consistent
contact pressure. This unique design
allows for the use of higher conductivity
material.
Box terminal design with pressure
plate (60 and 100A) permits greater
clamping pressure without damaging
conductors. Two clamping screws
provide secure terminations.
460C7W
Retaining Strap
SWING-AWAY CORD CLAMP
Wiring is simplified with swing-away cord
clamp. Strain relief clamp assembly swings
out for greater access when terminating
individual conductors and securing cord
clamp. Retaining strap maintains position of
upper strain relief during assembly. Includes
additional inserts to accommodate cords of
varying diameters.
WATERTIGHT
INLET
Specifications are subject to change without notice.
J
3
Ordering Data
Watertight Pin & Sleeve Devices
NOM
IP67
WATERTIGHT
20 AMP/30 AMP
60 AMP
North American Ratings
AMPS
20
30
60
J
4
POLES
AND
WIRES
CONFIGURATION
Recep./
Plug/
Conn.
Inlet
VOLTAGE
WATERTIGHT DEVICES
RECEPTACLE
PLUG
CONNECTOR
INLET
2P 3W
125V AC
320R4W
320P4W
320C4W
320B4W
2P 3W
250V AC
320R6W
320P6W
320C6W
320B6W
2P 3W
480V AC
320R7W
320P7W
320C7W
320B7W
3P 4W
125/250V AC
420R12W
420P12W
420C12W
420B12W
3P 4W
3Ø250
420R9W
420P9W
420C9W
420B9W
3P 4W
3Ø480
420R7W
420P7W
420C7W
420B7W
3P 4W
3Ø600
420R5W
420P5W
420C5W
420B5W
4P 5W
3ØY120/208
520R9W
520P9W
520C9W
520B9W
4P 5W
3ØY277/480
520R7W
520P7W
520C7W
520B7W
2P 3W
125V AC
330R4W
330P4W
330C4W
330B4W
2P 3W
250V AC
330R6W
330P6W
330C6W
330B6W
2P 3W
480V AC
330R7W
330P7W
330C7W
330B7W
3P 4W
125/250V AC
430R12W
430P12W
430C12W
430B12W
3P 4W
3Ø250
430R9W
430P9W
430C9W
430B9W
3P 4W
3Ø480
430R7W
430P7W
430C7W
430B7W
3P 4W
3Ø600
430R5W
430P5W
430C5W
430B5W
4P 5W
3ØY120/208
530R9W
530P9W
530C9W
530B9W
4P 5W
3ØY277/480
530R7W
530P7W
530C7W
530B7W
2P 3W
125V AC
360R4W
360P4W
360C4W
360B4W
2P 3W
250V AC
360R6W
360P6W
360C6W
360B6W
2P 3W
480V AC
360R7W
360P7W
360C7W
360B7W
3P 4W
125/250V AC
460R12W
460P12W
460C12W
460B12W
3P 4W
3Ø250
460R9W
460P9W
460C9W
460B9W
3P 4W
3Ø480
460R7W
460P7W
460C7W
460B7W
3P 4W
3Ø600
460R5W
460P5W
460C5W
460B5W
4P 5W
3ØY120/208
560R9W
560P9W
560C9W
560B9W
4P 5W
3ØY277/480
560R7W
560P7W
560C7W
560B7W
4P 5W
3ØY347/600
560R5W
560P5W
560C5W
560B5W
Requires AP2030 adapter plate - order separately. Also see Direct Mounting Back
Box (DM20301) page J-13.
Requires AP60 adapter plate - order separately. Also see Direct Mounting Back Box (DM602)
page J-13.
BACK BOX
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB601WA
BB602WA
BB601WA
BB602WA
BB601WA
BB602WA
BB601WA
BB602WA
BB601WA
BB602WA
BB601WA
BB602WA
BB601WA
BB602WA
BB601WA
BB602WA
BB601WA
BB602WA
BB601WA
BB602WA
For use with plugs and inlets. Provides watertight protection.
Specifications are subject to change without notice.
CLOSURE CAP
CC320A
CC320A
CC320A
CC420A
CC420A
CC420A
CC420A
CC520
CC520
CC330
CC330
CC330
CC330
CC330
CC330
CC330
CC530
CC530
CC560
CC560
CC560
CC560
CC560
CC560
CC560
CC560
CC560
CC560
Ordering Data
Watertight Pin & Sleeve Devices
NOM
IP67
WATERTIGHT
100 AMP
North American Ratings
AMPS
100
POLES
AND
WIRES
CONFIGURATION
Recep./
Plug/
Conn.
Inlet
VOLTAGE
WATERTIGHT DEVICES
RECEPTACLE
PLUG
CONNECTOR
INLET
2P 3W
250V AC
3100R6W
3100P6W
3100C6W
3100B6W
2P 3W
480V AC
3100R7W
3100P7W
3100C7W
3100B7W
3P 4W
125/250V AC
4100R12W
4100P12W
4100C12W
4100B12W
3P 4W
3Ø250
4100R9W
4100P9W
4100C9W
4100B9W
3P 4W
3Ø480
4100R7W
4100P7W
4100C7W
4100B7W
3P 4W
3Ø600
4100R5W
4100P5W
4100C5W
4100B5W
4P 5W
3ØY120/208
5100R9W
5100P9W
5100C9W
5100B9W
4P 5W
3ØY277/480
5100R7W
5100P7W
5100C7W
5100B7W
PLUG
CONNECTOR
V
D E
NOM
BACK BOX
BB1001WA
BB1002WA
BB1001WA
BB1002WA
BB1001WA
BB1002WA
BB1001WA
BB1002WA
BB1001WA
BB1002WA
BB1001WA
BB1002WA
BB1001WA
BB1002WA
BB1001WA
BB1002WA
CLOSURE CAP
CC510
CC510
CC510
CC510
CC510
CC510
CC510
CC510
IP67
WATERTIGHT
16 AMP/32 AMP/63 AMP/125 AMP
International Ratings
AMPS
16
32
63
125
POLES
AND
WIRES
CONFIGURATION
Recep./
Plug/
Conn.
Inlet
VOLTAGE
WATERTIGHT DEVICES
RECEPTACLE
INLET
2P 3W
100-130
316R4W
316P4W
316C4W
316B4W
2P 3W
200-250
316R6W
316P6W
316C6W
316B6W
3P 4W
380-415
416R6W
416P6W
416C6W
416B6W
4P 5W
200/346
240/415
516R6W
516P6W
516C6W
516B6W
2P 3W
100-130
332R4W
332P4W
332C4W
332B4W
2P 3W
200-250
332R6W
332P6W
332C6W
332B6W
3P 4W
380-415
432R6W
432P6W
432C6W
432B6W
3P 4W
380V 50Hz
440V 60Hz
432R3W
432P3W
432C3W
432B3W
4P 5W
200/346
240/415
532R6W
532P6W
532C6W
532B6W
2P 3W
200-250
363R6W
363P6W
363C6W
363B6W
3P 4W
380-415
463R6W
463P6W
463C6W
463B6W
4P 5W
200/346
240/415
563R6W
563P6W
563C6W
563B6W
3P 4W
380-415
4125R6W
4125P6W
4125C6W
4125B6W
4P 5W
200/346
240/415
5125R6W
5125P6W
5125C6W
5125B6W
Requires AP2030 adapter plate - order separately. Also see Direct Mounting Back Box (DM20301)
page J-13.
Requires AP60 adapter plate - order separately. Also see Direct Mounting Back Box (DM602) page J13.
BACK BOX
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB201WA
BB301WA
BB601WA
BB602WA
BB601WA
BB602WA
BB601WA
BB602WA
BB1001WA
BB1002WA
BB1001WA
BB1002WA
Requires AP100 adapter plate - order separately.
For use with plugs and inlets. Provides watertight protection.
Specifications are subject to change without notice.
CLOSURE CAP
CC320A
CC320A
CC420A
CC520
CC330
CC330
CC330
CC330
CC530
CC560
CC560
CC560
CC510
CC510
J
5
Dimensional Data
Watertight Pin & Sleeve Devices
A
C
B
20 AMP/30 AMP
60 AMP/100 AMP
WATERTIGHT PLUG
WATERTIGHT PLUG
KEY
A
B
C
3-WIRE
IN.
MM
2.75
4.37
5.42
20 AMP
4-WIRE
IN.
MM
5-WIRE
IN.
MM
70.5 3.04 78 3.37
112 4.37 112 4.60
139 5.42 139 5.66
CABLE GRIP .365" - .625"
86.5
118
145
3-WIRE
IN.
MM
3.67
5.62
6.67
30 AMP
4-WIRE
IN.
MM
5-WIRE
IN.
MM
60 AMP
4-WIRE
IN.
MM
3-WIRE
IN.
MM
5-WIRE
IN.
MM
3-WIRE
100 AMP
4-WIRE
IN.
IN.
MM
5-WIRE
MM
IN.
MM
94 3.67 94 3.96 101.5 4.43 113.5 4.43 113.5 4.43 113.5 4.88 125 4.88 125 4.88 125
144 5.62 144 5.62 144 8.81 226 8.81 226 8.81 226 9.87 253 9.87 253 9.87 253
171 6.67 171 6.67 171 9.91 254 9.91 254 9.91 254 11.15 286 11.15 286 11.15 286
CABLE GRIP .565"-.95"
CABLE GRIP .78"- 1.40"
CABLE GRIP .92"-1.72"
C
C
A
A
B
B
20 AMP/30 AMP
60 AMP/100 AMP
WATERTIGHT CONNECTOR
WATERTIGHT CONNECTOR
KEY
A
B
C
3-WIRE
IN.
MM
2.75
5.97
3.00
20 AMP
4-WIRE
IN.
MM
5-WIRE
IN.
MM
70.5 3.04 78 3.37
153 5.97 153 6.20
77 3.24 83 3.63
CABLE GRIP .365" - .625"
86.5
159
93
3-WIRE
IN.
MM
3.67
7.33
3.86
30 AMP
4-WIRE
IN.
MM
5-WIRE
IN.
MM
60 AMP
4-WIRE
IN.
MM
3-WIRE
IN.
MM
5-WIRE
IN.
MM
3-WIRE
IN.
MM
100 AMP
4-WIRE
IN.
MM
94 3.67 94 3.96 101.5 4.29 110 4.29 110 4.29 110 4.91 126 4.91 126 4.91 126
188 7.33 188 7.33 188 10.61 272 10.61 272 10.61 272 12.01 308 12.01 308 12.01 308
99 3.86 99 4.17 107 4.43 113.5 4.43 113.5 4.43 113.5 4.99 128 4.99 128 4.99 128
CABLE GRIP .565"-.95"
CABLE GRIP .78"- 1.40"
CABLE GRIP .92"-1.72"
E
K
A
I
C
J
20 AMP/30 AMP
J
6
F
D
B
WATERTIGHT RECEPTACLE
20 AMP
4-WIRE
3-WIRE
5-WIRE
IN.
MM
G
5-WIRE
H
30 AMP
4-WIRE
3-WIRE
5-WIRE
KEY
IN.
MM
IN.
MM
IN.
MM
IN.
MM
IN.
MM
IN.
MM
A
B
C
D
E
F
G
H
I
J
K
2.93
2.93
2.34
2.34
.22
.27
.66
2.22
2.96
1.76
.14
75
75
60
60
5.5
7
17
57
76
45
3.5
2.93
2.93
2.34
2.34
.22
.27
1.01
2.26
3.24
1.76
.27
75
75
60
60
5.5
7
26
58
83
45
7
2.93
2.93
2.34
2.34
.22
.27
.66
2.22
3.63
2.15
.45
75
75
60
60
5.5
7
17
57
93
55
11.5
2.93
2.93
2.34
2.34
.22
.31
1.40
2.54
3.9
2.34
.47
75
75
60
60
5.5
8
36
65
100
60
12
2.93
2.93
2.34
2.34
.22
.31
1.40
2.54
3.9
2.34
.47
75
75
60
60
5.5
8
36
65
100
60
12
2.93
2.93
2.34
2.34
.22
.31
.74
2.54
3.9
2.34
.66
75
75
60
60
5.5
8
19
65
100
60
17
Specifications are subject to change without notice.
Dimensional Data
Watertight Pin & Sleeve Devices
E
K
A
I
J
C
60 AMP/100 AMP
WATERTIGHT RECEPTACLE
F
D
B
60 AMP
4-WIRE
3-WIRE
G
5-WIRE
H
100 AMP
4-WIRE
3-WIRE
5-WIRE
KEY
IN.
MM
IN.
MM
IN.
MM
IN.
MM
IN.
MM
IN.
MM
A
B
C
D
E
F
G
H
I
J
K
4.17
3.9
3.32
3.00
.25
.47
2.20
2.96
4.41
3.43
.27
107
100
85
77
6.5
12
56.5
76
113
88
7
4.17
3.9
3.32
3.00
.25
.47
2.20
2.96
4.41
3.43
.27
107
100
85
77
6.5
12
56.5
76
113
88
7
4.17
3.9
3.32
3.00
.25
.47
2.20
2.96
4.41
3.43
.27
107
100
85
77
6.5
12
56.5
76
113
88
7
4.68
4.68
3.9
3.9
.25
.82
1.95
4.56
5.03
3.62
.23
120
120
100
100
6.5
21
50
117
129
92
6
4.68
4.68
3.9
3.9
.25
.82
1.95
4.56
5.03
3.62
.23
120
120
100
100
6.5
21
50
117
129
92
6
4.68
4.68
3.9
3.9
.25
.82
1.95
4.56
5.03
3.62
.23
120
120
100
100
6.5
21
50
117
129
92
6
B
E
A
D
F
C
10°
H
20 AMP/30 AMP/60AMP
WATERTIGHT INLET
KEY
A
B
C
D
E
F
G
H
I
3-WIRE
IN.
MM
3.32
3.32
2.73
2.73
.25
.43
4.06
3.24
2.75
85
85
70
70
6.3
11
104
83
70.5
I
DIA.
20 AMP
4-WIRE
IN.
MM
3.32
3.32
2.73
2.73
.25
.43
4.29
3.51
3.10
5-WIRE
IN.
MM
85
85
70
70
6.3
11
110
90
79.5
3.32
3.32
2.73
2.73
.25
.43
4.53
3.59
3.37
85
85
70
70
6.3
11
116
92
86.5
3-WIRE
IN.
MM
3.32
3.32
2.73
2.73
.25
.43
4.72
3.78
3.71
85
85
70
70
6.3
11
121
97
95
30 AMP
4-WIRE
IN.
MM
3.32
3.32
2.73
2.73
.25
.43
4.72
3.78
3.71
85
85
70
70
6.3
11
121
97
95
5-WIRE
IN.
MM
3.32
3.32
2.73
2.73
.25
.43
4.95
3.94
3.96
85
85
70
70
6.3
11
127
101
101.5
100 AMP
WATERTIGHT INLET
E
A
KEY
B
D
H
C
I
DIA.
Specifications are subject to change without notice.
F
J
G
K
A
B
C
D
E
F
G
H
I
J
K
G
3-WIRE
IN.
MM
4.17
3.9
3.32
3.00
.25
.47
6.05
4.60
4.43
107
100
85
77
6.5
12
155
118
113.5
3-WIRE
IN.
MM
5.07
4.68
4.21
3.9
.25
.51
5.07
5.27
4.91
.90
4.06
130
120
108
100
6.5
13
130
135
126
23
104
60 AMP
4-WIRE
IN.
MM
4.17
3.9
3.32
3.00
.25
.47
6.05
4.60
4.43
107
100
85
77
6.5
12
155
118
113.5
100 AMP
4-WIRE
IN.
MM
5.07
4.68
4.21
3.9
.25
.51
5.07
5.27
4.91
.90
4.06
130
120
108
100
6.5
13
130
135
126
23
104
5-WIRE
IN.
MM
4.17
3.9
3.32
3.00
.25
.47
6.05
4.60
4.43
IN.
107
100
85
77
6.5
12
155
118
113.5
5-WIRE
MM
5.07
4.68
4.21
3.9
.25
.51
5.07
5.27
4.91
.90
4.06
130
120
108
100
6.5
13
130
135
126
23
104
J
7
Specifications
Watertight Pin & Sleeve Devices
WATERTIGHT
MATERIALS
Receptacle
Housing/Mounting Flange — Toughened Nylon
Cover Arm — Toughened Nylon
Cover Ring — Polycarbonate
Cover Spring — Stainless Steel
Seals/Gaskets — Neoprene, EPDM, TPE
Contact Carrier — Glass-Reinforced Nylon
Terminal Cover — Toughened Nylon
Phase/Ground Sleeves — Brass
Sleeve Spring — Nickel-Plated Spring Steel
Hinge Pins — Brass
Mounting Screws — Stainless Steel
Terminal Screws — Plated Steel
Plug
Housing — Toughened Nylon
Cord Clamp Assembly — Toughened Nylon
Gland Nut — Toughened Nylon
Cord Gland — Neoprene
Locking Ring — Polycarbonate
Seals/Gaskets — Neoprene, EPDM, TPE
Contact Carrier — Glass-Reinforced Nylon
Terminal Cover — Toughened Nylon
Phase/Ground Pins — Brass
Gland Friction Washer — Plated Carbon Steel
(30, 60, 100A), Nylon (20A)
Assembly Screws — Stainless Steel (60/100A),
Plated Steel (20/30A)
Terminal Screws — Plated Steel
Connector
Housing — Toughened Nylon
Cord Clamp Assembly — Toughened Nylon
Gland Nut — Toughened Nylon
Cord Gland — Neoprene
Cover Ring — Polycarbonate
Cover Spring — Stainless Steel
Seals/Gaskets — Neoprene, EPDM, TPE
Contact Carrier — Glass-Reinforced Nylon
Terminal Cover — Toughened Nylon
Phase/Ground Sleeves — Brass
Sleeve Spring — Nickel-Plated Spring Steel
Hinge Pins — Brass
Gland Friction Washer — Plated Carbon Steel
(30, 60, 100A), Nylon (20A)
Assembly Screws — Stainless Steel (60/100A),
Plated Steel (20/30A)
Terminal Screws — Plated Steel
Inlet
Housing — Toughened Nylon
Mounting Flange — Toughened Nylon
Locking Ring — Polycarbonate
Seals/Gaskets — Neoprene, EPDM, TPE
Contact Carrier — Glass-Reinforced Nylon
Terminal Cover — Toughened Nylon
Phase/Ground Pins — Brass
Assembly Screws — Stainless Steel (60/100A),
Plated Steel (20/30A)
Terminal Screws — Plated Steel
Mounting Screws — Stainless Steel
J
8
LISTINGS
UL Listed Standard 1682 (plugs, receptacles, and cable connectors, of
the pin & sleeve type).
Conforms to UL1686 (pin & sleeve configuration).
CSA Certified C22.2 NO. 182.1 - 1988
Complies with IEC 309-1 and 309-2 International Standards
for singly-rated non-interchangeable configurations
Meet 1997 UL 1682 and 1686 requirements
NOM
CE
PERFORMANCE
Electrical:
Dielectric Voltage Withstand — 3,000 Volts-Receptacle; 2,200 Volts-Plug
& Connector
Max. Working Voltage — 600 Volts AC
Spacings — 1/4" minimum creepage and clearance per UL 1682
Current Interrupting — Certified for current interrupting at full rated current
where applicable per UL 1682
Temperature Rise — Less than 30°C temperature rise at full rated current
after 50 cycles of overload tested at 150% of rated current at .75 pf.
Endurance — Up to 5,000 connect and disconnect cycles at full-rated current and voltage per UL 1682
Mechanical:
Impact Resistance — After 6 hours at -25°C, 8 drops from
21/2' with 71/2' length cord
Mechanical Crush Test — 250 lbs. force for 1 minute after 6 hours at 25°C
Terminal Identification — Terminals identified in accordance with North
American Codes
Product Identification — Catalog number and rating
indicated on device
Environmental:
Moisture Resistance — Submerged 24 hours at 2" below water surface
Flammability (Enclosure) — V2 minimum per UL 94
Operating Temperatures — Maximum continuous 95°C with impact, minimum continuous -40°C without impact
Moisture Protection — IP67
Polarization Integrity — Mating devices will not energize ground if polarization feature is removed and 40 lbs. force
is applied
The following international electrical regulatory agencies
recognize IEC 309 standard Pin & Sleeve devices.
OVE
CEBEC
Austria
Belgium
Czech Republic
V
D E
Finland
Germany
Denmark
I
Great Britain
Hungary
Norway
Sweden
EUR
K EMA
Except 60A (Nylon)
Except 100A (Glass-reinforced Nylon)
Specifications are subject to change without notice.
Italy
Netherlands
Product Features
Splashproof Pin & Sleeve Devices
Singly-rated, non-interchangeable configurations in
accordance with IEC 309-1 and 309-2 standards.
Prevents mismating of devices with different
voltage ratings. Color coded for easy identification.
Neoprene sealing glands seal
out moisture and contaminants at cord entry
and can accommodate a variety of cord
diameters.
IP44
Ground contact in
forward position to ensure first
make, last break. Neutral
contact connects next, then
phase contacts.
Gland nut and ring compress
sealing gland around cord to
seal out contaminants.
Provides supplemental strain
relief.
Combination straight/Phillips head cord grip,
terminal and assembly screws, and single side
terminals simplify wiring.
Self-adjusting, slotted contact sleeve and
nickel-plated spring steel contact pressure
spring ease insertion of pins and provide
consistent contact pressure.
Insulated nylon housing
resists impact, corrosion,
and chemical attack.
Cord clamp screws fasten into threaded, plated
steel nuts to prevent strip-out.
Pins are recessed in shrouded
housing for protection from abuse.
Pins and sleeves are fabricated from solid
brass for longevity, contact reliability, and
superior conductivity.
Not every application requires heavy-duty watertight protection. For those situations where devices
are exposed to limited splashing of water or other
liquids, Bryant offers splashproof devices in six of
the most popular international voltage and amperage ratings.These devices are ideally suited for
OEM manufacturers who build equipment for
export overseas. These situations require devices
which can withstand impact from handling and fluctuations in heat and cold without interruption of
Specifications are subject to change without notice.
performance. The Splashproof series lives up to the
challenge. Available in 16 and 32A, our splashproof devices meet IEC 309-1 and IEC 309-2 standards, resulting in singly rated, non-interchangeable configurations. They comply with VDE and CE
requirements and have a moisture resistance
rating of IP44. Like their watertight counterparts,
these devices simply cannot be mismated.
Designed for value and performance, these
devices integrate the key features that make
Bryant Pin & Sleeve devices the standard of the
industry. Reliable. Durable. Built to last. Bryant
splashproof receptacles, plugs and connectors
offer
a full measure of splash protection for dependable
connections.
J
9
ORDERING DATA
NOM IP44
V
D E
SPLASHPROOF
16 AMP/32 AMP
International Ratings
POLES
AND
WIRES
AMPS
16
32
CONFIGURATION
Recep./
Plug/
Conn.
Inlet
SPLASHPROOF DEVICES
VOLTAGE
RECEPTACLE
PLUG
CONNECTOR
2P 3W
100-130
316R4S
316P4S
316C4S
2P 3W
200-250
316R6S
316P6S
316C6S
3P 4W
380/415
416R6S
416P6S
416C6S
4P 5W
200/346
240/415
516R6S
516P6S
516C6S
2P 3W
100-130
332R4S
332P4S
332C4S
2P 3W
200-250
332R6S
332P6S
332C6S
BACK BOX
BB201W
BB301W
BB201W
BB301W
BB201W
BB301W
BB201W
BB301W
BB201W
BB301W
BB201W
BB301W
DIMENSIONAL DATA
SPLASHPROOF PLUG
16A 3-WIRE
KEY
16A 4-WIRE
MM
IN.
16A 5-WIRE
MM
IN.
A
51
1.99
58
2.26
64
2.50
66
2.57
B
138
5.38
138
5.38
143
5.58
175
6.83
C
102
3.99
102
3.98
107
4.17
130
5.07
D
17
0.66
17
0.66
17
0.66
24.5
0.96
SPLASHPROOF CONNECTOR
16A 3-WIRE
16A 4-WIRE
16A 5-WIRE
D
A
B
B
32A 3-WIRE
MM
IN.
MM
IN.
MM
IN.
MM
IN.
A
51
1.99
58
2.26
64
2.50
66
2.57
B
150
5.85
151
5.89
155
6.05
188
7.33
C
17
0.66
17
0.66
17
0.66
24.5
0.96
D
71
2.77
79
3.08
85
3.32
93
3.63
KEY
MM
IN.
MM
IN.
MM
IN.
MM
IN.
A
75
2.93
75
2.93
75
2.93
75
2.93
B
75
2.93
75
2.93
75
2.93
75
2.93
C
47
2.34
60
2.34
60
2.34
60
2.34
D
47
2.34
60
2.34
60
2.34
60
2.34
E
5.5
0.22
5.5
0.22
5.5
0.21
5.5
0.21
F
7
0.27
7
0.27
7
0.27
8
0.31
G
17
0.66
26
1.01
17
0.66
36
1.40
16A 4-WIRE
A
IN.
KEY
16A 3-WIRE
10
MM
C
SPLASHPROOF RECEPTACLE
J
IN.
32A 3-WIRE
MM
16A 5-WIRE
51
1.99
53
2.07
53
2.07
62
2.42
I
70
2.73
80
3.12
85
3.32
90
3.51
J
45
1.76
45
1.76
55
2.15
60
2.34
K
3.5
0.4
7
0.27
11.5
1.45
12
.47
CONNECTOR
PLUG
32A 3-WIRE
H
C
D
E
K
I
A C
Requires AP2030 adapter plate - order separately. Also see Direct Mounting Back Box (DM20301) page J-13.
Specifications are subject to change without notice.
D
B
G
F
H
RECEPTACLE
J
Specifications
Splashproof Pin & Sleeve Devices
SPLASHPROOF
MATERIALS
Receptacle
Housing/Mounting Flange — Toughened Nylon
Cover/Arm — Toughened Nylon
Cover Spring — Stainless Steel
Seals/Gaskets — Neoprene, EPDM, TPE
Hinge Pins — Brass
Contact Carrier — Glass-Reinforced Nylon
Terminal Cover — Toughened Nylon
Phase/Ground Sleeves — Brass
Sleeve Spring — Nickel-Plated Spring Steel
Mounting Screws — Stainless Steel
Terminal Screws — Plated Steel
Plug
Housing — Toughened Nylon
Cord Clamp Assembly — Toughened Nylon
Gland Nut — Toughened Nylon
Cord Gland — Neoprene
Seals/Gaskets — Neoprene, EPDM, TPE
Contact Carrier — Glass-Reinforced Nylon
Terminal Cover — Toughened Nylon
Phase/Ground Pins — Brass
Gland Friction Washer — Plated Carbon Steel
32A; Nylon 16A
Assembly Screws — Plated Steel
Terminal Screws — Plated Steel
Connector
Housing — Toughened Nylon
Cord Clamp Assembly — Toughened Nylon
Gland Nut — Toughened Nylon
Cord Gland — Neoprene
Cover Spring — Stainless Steel
Seals/Gaskets — Neoprene, EPDM, TPE
Contact Carrier — Glass-Reinforced Nylon
Terminal Cover — Toughened Nylon
Phase/Ground Sleeves — Brass
Sleeve Spring — Nickel-Plated Spring Steel
Hinge Pins — Brass
Gland Friction Washer — Plated Carbon Steel
32A; Nylon 16A
Assembly Screws — Plated Steel
Terminal Screws — Plated Steel
LISTINGS
Complies with IEC 309-1 and 309-2 international standards
for singly-rated non-interchangeable configurations
CE
VDE
NOM
PERFORMANCE
Electrical:
Dielectric Voltage Withstand — 3,000 Volts-Receptacle; 2,200 Volts — Plug &
Connector
Max. Working Voltage — 500 Volts AC
Spacings — 1/4" minimum creepage and clearance
Current Interrupting — Certified for current interrupting at full rated current
Endurance — Up to 5,000 connect and disconnect cycles at full-rated current and
voltage
Mechanical:
Impact Resistance — After 6 hours at -25°C, 8 drops from 2 1/2” with 7 1/2”' length
cord
Mechanical Crush Test — 250 lbs. force for 1 minute after
6 hours at -25°C
Terminal Identification — Terminals identified in accordance with IEC 309
Product Identification — Catalog number and rating
indicated on device
Environmental:
Flammability (Enclosure) — V2 minimum per UL 94
Operating Temperatures — Maximum continuous 95°C with impact, minimum
continuous -40°C without impact
Moisture Protection — IP44
Polarization Integrity — Mating devices will not energize ground if polarization
feature is removed and 40 lbs. force
is applied
The following international electrical regulatory agencies
recognize IEC 309 standard Pin & Sleeve devices.
OVE
CEBEC
Austria
Belgium
Czech Republic
V
D E
Finland
Germany
Denmark
I
Great Britain
Hungary
Norway
Sweden
EUR
K EMA
Italy
Specifications are subject to change without notice.
Netherlands
J
11
Accessories
Pin & Sleeve Devices
To complete your installation, Bryant offers a full line of back boxes, adapter plates and
closure caps. Pin & Sleeve accessories feature the heavy-duty construction and durability
you require for reliable performance in harsh environments.
BACK BOXES
Bryant offers a complete line of angled and feed-thru back boxes for mounting receptacles
and inlets. Each back box features heavy-duty cast aluminum construction with a durable
enamel finish. Adapter plate required to mount receptacles and inlets to back boxes - order
separately. See ordering information below.
B
E
D
B
D
E
E
F
A
A
C
B
C
CATALOG
NUMBER
DESCRIPTION
FOUR-WAY BOX
HUB
SIZE
IN. MM
FEED-THRU BOX
DIMENSIONS
A
IN.
B
C
D
E
CAPACITY
F
MM
IN.
MM
IN.
MM
IN.
MM
IN.
MM
IN.
MM
CU.IN.
CM3
BB201WA
15° angle - 20/30A devices
.75
19.2 5.12
131.3
4.0
102.6
4.19
107.4
3.75
96.2
3.0
76.9
4.0
102.6
30
492
BB301WA
15° angle - 20/30A devices
1.0
25.6 5.12
131.3
4.0
102.6
4.19
107.4
3.75
96.2
3.0
76.9
4.0
102.6
30
492
BB601WA
15° angle - 60A devices
1.25 32.1 7.25
185.9
5.25
134.6
6.0
153.9
4.50
115.4
3.75
96.2
6.19
158.7
80
1312
BB602WA
15° angle - 60A devices
1.50 38.5 7.25
185.9
5.25
134.6
6.0
153.9
4.50
115.4
3.75
96.2
6.19
158.7
80
1312
BB1001WA
15° angle - 100A devices
1.50 38.5 8.12
208.2
6.75
173.1
6.88
176.4
5.50
141
4.75
121.8
6.31
161.8
130
2132
BB1002WA
15° angle - 100A devices
2.0
51.3 8.12
208.2
6.75
173.1
6.88
176.4
5.50
141
4.75
121.8
6.31
161.8
130
2132
FT202WA
Feed-thru - 20/30A devices
.75
19.2 8.25
211.5
3.06
78.5
7.14
183.1
4.50
115.4
3.75
96.2
–
–
48
787
FT302WA
Feed-thru - 20/30A devices
1.0
25.6 8.25
211.5
3.06
78.5
7.14
183.1
4.50
115.4
3.75
96.2
–
–
48
787
FW60100A
Four-way - 60/100A devices
1.50 38.5 8.75
224.4
9.75
250
7.75
198.7
6.75
173.1
6.0
153.9
–
–
210
3444
.22 dia. thru
(5.6)
.18 dia.
(4.6)
ADAPTER PLATES
Nylon adapter plates permit
receptacles and inlets to be
mounted to back boxes.
Mounting hardware and
gasket included.
CAT. NO.
AP2030
AP60
12
C
D
ANGLE BOX
J
A
AP100
.22 dia. thru
(5.6)
DESCRIPTION
Required to mount 20 & 30A
receptacles and inlets to BB201W, BB301W,
FT202W, FT302W
back boxes
Required to mount 60A receptacles and inlets
to BB601W, BB602W and FW60100 back
boxes
Required to mount 100A receptacles and
inlets to BB1001W and BB1002W back boxes
Requires AP2030 adapter plate - order separately.
Requires AP60 adapter plate - order separately.
Requires AP100 adapter plate - order separately.
.18 dia.
(4.6)
20/30A
60A
D
C
B
A
E
.22 dia. thru
(5.6)
100A
F
A
E
G
B
A
AP60
AP100
B
AP2030
.18 dia.
(4.6)
CATALOG NUMBER
KEY
AP2030
IN.
A
B
C
D
E
F
G
3.76 SQ.
3.13 SQ.
2.76 SQ.
2.36 SQ.
–
–
–
AP60
MM
96.4 SQ.
80.3 SQ.
70.8 SQ.
60.5 SQ.
–
–
–
AP100
IN.
MM
4.51 SQ.
3.88 SQ.
–
–
3.03
3.35
–
115.6 SQ.
99.5 SQ.
–
–
77.7
85.9
–
IN.
5.52 SQ.
4.87 SQ.
–
–
3.94 SQ.
–
4.25
Requires AP60 adapter plate to mount 60A receptacle or inlet. 100A receptacle
mounts directly to box. 100A inlet does not mount to this box.
Specifications are subject to change without notice.
MM
141.5 SQ.
124.9 SQ.
–
–
101 SQ.
–
109
Accessories
Pin & Sleeve Devices
DIRECT MOUNTING
BACK BOXES
15° angle cast aluminum back boxes permit
20, 30 and 60A receptacles to be mounted
directly to box
without adapter plate.
A
C
D
B
CATALOG
NUMBER
DIMENSIONS
HUB
SIZE
DESCRIPTION
A
B
C
CAPACITY
D
IN.
MM
IN.
MM
IN.
MM
IN.
MM
IN.
MM
CU.IN.
CM3
DM20301
15° angle - 20/30A devices
.75
19.2
5.07
130
3.38
78
4.13
106
3.62
93
20
328
DM602
15° angle - 60A devices
1.25
32.1
5.81
149
4.28
110
4.56
117
4.58
117
40
656
CLOSURE CAPS
Closure caps provide a watertight
seal for male plugs and flanged
inlets when not mated. Thick wall,
heavy-duty thermoplastic construction protects male pins from contaminants and abuse. Ideal for applications in wash down areas or
when equipment is being transported.
CATALOG NUMBER
FOR USE WITH
CC320A
16/20A - 3-Wire devices
CC420A
16/20A - 4-Wire devices
CC520
16/20A - 5-Wire devices
CC330
30/32A - 3-Wire, 4-Wire devices
CC530
30/32A - 5-Wire devices
CC560
60/63A - 3, 4, 5-Wire devices
CC510
100/125A - 3, 4, 5-Wire devices
GUIDE TO WATERTIGHT APPLICATIONS
INDUSTRY
APPLICATION
Agriculture
For farming applications including outdoor fans, HVAC pumps, heaters and related equipment
Chemical Processing
Areas where equipment is exposed to water or corrosive chemicals
Computer Processing
To maintain critical continuous connection in enclosed floors or other spaces where moisture may be present
Construction
Outdoor environments where exposed to moisture, severe weather/temperature, and rugged handling
Entertainment
For outdoor sound and lighting applications subject to weather and temperature changes
Food Processing
For use in areas exposed to wash downs, chemicals, and rough handling
Food Service
Indoor use where subject to water, chemical, and cleaning agents
Light Manufacturing
Industrial areas where exposed to water, cleaners, solvents, and chemicals
Manufacturing
Industrial locations subject to water, chemicals, contaminants, impact, crushing, and rough use
Military
Outdoor environments subject to water, severe weather/temperature changes, and rough handling
Wastewater Treatment
For safe connection in outdoor areas prone to moisture and chemical exposure
Specifications are subject to change without notice.
J
13
Product Features
Unfused Pin & Sleeve
Mechanical Interlocks
Heavy-Duty Construction for Demanding Applications
Bryant’s rugged new mechanical interlocks combine the safety of a disconnect switch and IEC 309 pin and sleeve receptacle in one compact nonmetallic
enclosure. Designed to meet the National Electrical Code requirements for a
separate disconnect means within sight of all motor loads, the enclosures
provide ON/OFF switched control of a plug connected load. The interlocking
feature prevents the plug from being disconnected while the receptacle is energized. The switch cannot be turned ON until the plug is properly inserted. The
plug can not be removed until the switch is turned OFF. Durable, watertight and
30 and 60 amp units provide
top or bottom feed option
Heavy-duty deep
slotted non-metallic cover
screws resist corrosion
Color-coded receptacle cover insert
provides voltage
rating identification
Interlocks are compatible with
IEC 309-2 plugs
J
14
Bryant Electric, Inc. is approved for Quality Management Systems in accordance with ISO 9002.
Heavy-duty disconnect switches
are horse-power rated for motor
load applications
Watertight conduit hub and
grounding plate included for
use with metallic conduit
NEMA 4x and 12 enclosures provide watertight
and dust tight protection
Impact corrosion resistant
thermoplastic enclosure
Watertight receptacle cover
“top-hinge” mounted,
reduces potential for accumulation and infiltration of
contaminants.
corrosion-resistant, these interlocks are IP67 rated and may be locked out as a
method of compliance with OSHA Lockout/Tagout regulations. Bryant mechanical interlocks are available in 20, 30, 60 and 100 amp ratings and 3, 4 or 5 wire
configurations.
Specifications are subject to change without notice.
Handle can be
padlocked
to comply
with OSHA lockout/tagout requirements
Switches are DIN rail
mounted for easy installations
Prewired IEC Pin & Sleeve
receptacle
Neutral and ground terminal
blocks are conveniently
located for easy accessibility
and wiring
Pin & Sleeve Mechanical Interlocks
20, 30, 60, 100 Amp
Features - Specifications
NEMA 4x and 12 enclosures provide watertight and dust tight protection
Impact, corrosion-resistant thermoplastic
enclosure
Handle can be padlocked to comply with
OSHA lockout/tagout requirements
Watertight conduit hub and grounding plate
included for use with metallic conduit
Heavy-duty disconnect switches are horsepower rated for motor load
applications
AMPS
20
30
460SMI7W
32
60
APPLICATIONS
Mechanical Interlocks combine the
safety of a disconnect switch and
IEC pin and sleeve receptacle in
one compact nonmetallic enclosure
and provide ON/OFF switched
control of a plug connected load.
Interlocking feature prevents the
plug from being disconnected while
the receptacle is energized. The
switch cannot be turned ON until
plug is properly inserted. Plug can
not be removed until the switch is
turned OFF.
100
POLES
AND
WIRES
CONFIGURATION
Recep./
Plug/
Conn.
Inlet
30 and 60 amp units provide top or bottom
feed option.
20 and 100 amp are top feed
Complies with UL50, UL746C and IEC 309
IP67 Suitability
Watertight receptacle cover opens from front
of receptacle. Reduces potential for
accumulation of dust and moisture inside
cover
Color-coded receptacle cover insert
provides voltage rating identification
UL 508–Industrial Control Equipment
Manual Motor Controller
CSA C22.2 No. 14
VOLTAGE
INTERLOCK
MATING PLUG
3P 4W
240V AC 3Ø
420SMI9W
420P9W
3P 4W
480V AC 3Ø
420SMI7W
420P7W
3P 4W
600V AC 3Ø
420SMI5W
420P5W
2P 3W
120V AC
330SMI4W
330P4W
2P 3W
240V AC
330SMI6W
330P6W
2P 3W
480V AC
330SMI7W
330P7W
3P 4W
240V AC 3Ø
430SMI9W
430P9W
3P 4W
480V AC 3Ø
430SMI7W
430P7W
3P 4W
600V AC 3Ø
430SMI5W
430P5W
4P 5W
120/208V AC 3ØY
530SMI9W
530P9W
4P 5W
277/480V AC 3ØY
530SMI7W
530P7W
3P 4W
380V AC 3Ø 50Hz
440V AC 3Ø 60Hz
432SMI3W
432P3W
2P 3W
120V AC
360SMI4W
360P4W
2P 3W
240V AC
360SMI6W
360P6W
2P 3W
480V AC
360SMI7W
360P7W
3P 4W
240V AC 3Ø
460SMI9W
460P9W
3P 4W
480V AC 3Ø
460SMI7W
460P7W
3P 4W
600V AC 3Ø
460SMI5W
460P5W
4P 5W
120/208V AC 3ØY
560SMI9W
560P9W
4P 5W
277/480V AC 3ØY
560SMI7W
560P7W
4P 5W
347/600V AC 3ØY
560SMI5W
560P5W
2P 3W
240V AC
3100SMI6W
3100P6W
3P 4W
240V AC 3Ø
4100SMI9W
4100P9W
3P 4W
480V AC 3Ø
4100SMI7W
4100P7W
3P 4W
600V AC 3Ø
4100SMI5W
4100P5W
4P 5W
120/208V AC 3ØY
5100SMI9W
5100P9W
Mating plug sold separately.
Specifications are subject to change without notice.
J
15
Specifications
Pin & Sleeve Mechanical Interlock
Environmental:
MECHANICAL INTERLOCK
Moisture Resistance — Outdoor - 4x (Watertight, Washdown) IP67, Indoor — 12
(Dust tight, Falling Dirt and Noncorrosive Liquids)
Flammability — UL94-5V and VO Classification
Operating Temperature — Max. Continuous +60ÞC;
Min. Continuous -40ÞC
UV Resistance — All exposed materials are UV stabilized
MATERIALS
Enclosure Base — Valox ®
Enclosure Cover — Valox
Handle — Valox
Enclosure Gasket — Neoprene
Enclosure Screws — Valox
Hinge Pins — Stainless Steel
Hinge Spring — Stainless Steel
Conduit Hub — Zinc
Ground Plate — Galvanized Steel
Cover Gasket — Neoprene
HORSEPOWER RATINGS
CAT. NO.
LISTINGS
UL 508 - Industrial Control Equipment,
Manual Motor Controller
CSA Certified C22.2 No. 14
Complies with UL 50, UL 746C and IEC 309
Configuration meets UL 1686
IP67 Suitability
PERFORMANCE
Electrical:
Dielectric Voltage Withstand — 3,000 Volts min.
Max. Working Voltage — 600 Volts RMS
Current Interrupting — Certified for current interrupting at full rated current and
voltage
Short Circuit Withstand Rating — Suitable for use on a circuit capable of delivering not more that 10,000 RMS symmetrical amperes at the voltage rating of the
receptacle (30, 60, 100A)
Operations — Mechanical - 10,000 Cycles, Electrical 6,000 Cycles
Mechanical:
Impact Resistance — In accordance with UL 746C
Terminal Identification — In accordance with UL, CSA
and international conventions
Product Identification — Identification and ratings are part of the external label
AMPS
RATING
HORSEPOWER
420SMI9W
420SMI7W
420SMI5W
20
20
20
240V AC 3Ø
480V AC 3Ø
600V AC 3Ø
5
10
15
330SMI4W
330SMI6W
330SMI7W
430SMI9W
430SMI7W
430SMI5W
530SMI9W
530SMI7W
30
30
30
30
30
30
30
30
120V AC
240V AC
480V AC
240V AC 3Ø
480V AC 3Ø
600V AC 3Ø
120/208V AC 3ØY
277/480V AC 3ØY
2
3
7.5
7.5
15
20
5
15
432SMI3W
32
380V AC 3Ø 50 Hz
440V AC 3Ø 60Hz
15 (440V AC3Ø 60 Hz)
360SMI4W
360SMI6W
360SMI7W
460SMI9W
460SMI7W
460SMI5W
560SMI9W
560SMI7W
560SMI5W
60
60
60
60
60
60
60
60
60
120V AC
240V AC
480V AC
240V AC 3Ø
480V AC 3Ø
600V AC 3Ø
120/208V AC 3ØY
277/480V AC 3ØY
347/600V AC 3ØY
3
7.5
20
15
30
40
15
30
40
3100SMI6W
4100SMI9W
4100SMI7W
4100SMI5W
5100SMI9W
100
100
100
100
100
240V AC
240V AC 3Ø
480V AC 3Ø
600V AC 3Ø
120/208V AC 3ØY
15
25
40
50
20
PRODUCT DIMENSIONS
A
C
I CONDUIT
DIA. G
HUB SIZE
H
A
I CONDUIT
C
DIA. G
A
A
C
C
I CONDUIT
DIA. G
HUB SIZE
I CONDUIT
DIA. G
HUB SIZE
HUB SIZE
D B
H
H
F
H
D B
D B
D B
E
KEY
A
B
C
D
E
F
G DIA.
H
I
J
16
20 AMP
INCHES
4.65
8.86
3.98
8.19
5.00
9.65
.26
.31
3/4" NPT
F
F
F
E
E
MM
118
225
101
208
127
245
6.5
8
Valox® is a registered trademark of GE Company.
Specifications are subject to change without notice.
KEY
A
B
C
D
E
F
G DIA.
H
I
30 AND 32 AMP
INCHES
MM
6.30
160
10.24
260
5.51
140
9.45
240
6.78
172
11.68
297
.32
8.1
.39
10
1" NPT
E
KEY
A
B
C
D
E
F
G DIA.
H
I
60 AMP
INCHES
6.30
10.24
5.51
9.45
7.68
11.97
.32
.39
1-1/4"NPT
MM
160
260
140
240
195
304
8.1
10
KEY
A
B
C
D
E
F
G DIA.
H
I
100 AMP
INCHES
7.09
18.11
6.30
17.32
8.19
20.08
.33
.26
1-1/4"NPT
MM
180
460
160
440
208
510
8.3
6.5
Download