tyton® fittings

advertisement
2 0 0 9
E d i t i o n
Tyton fittings
®
14"-24"
NSF
®
Certified to
ANSI/NSF 61
For Water & Wastewater, Fire Protection & Industrial Applications
866.DIP.PIPE
TYTON Fittings
®
NSF
2009
®
Certified to
ANSI/NSF 61
Edition
P2
Table of Contents
TYTON Fittings
3
Assembly of TYTON Fittings
4
Bell Dimensions
6
Thickness and Dimensions
90° Bends
45° Bends
22-1/2° Bends
30° Bends
11-1/4° Bends
5-5/8° Bends
Tees and Crosses
Flanged Outlet Tees
Bell x Bell Concentric Reducers, 14"-24"
Large End Bell and Small End Bell
Concentric Reducers, 14"-24"
TYTON Plugs
Products for Water, Waste Water,
and Fire Protection
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
7
8
9
9
10
11
12
14
16
17
19
20
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
2009
®
Certified to
ANSI/NSF 61
Edition
P3
TYTON Fittings
TYTON JOINT® Pipe (push-on) has become so popular since its introduction in 1956 that it now
constitutes more than 95% of the pipe shipped by U.S. Pipe. In 1965, U.S. Pipe introduced
4"–12"* TYTON® Fittings. Later, U.S. Pipe introduced 14"–24". TYTON Fittings are also produced
in metric diameters for the international market. (See U.S. Pipe’s International Catalog.)
Fittings shall be push-on joint Ductile Iron fittings with a pressure rating of 350 psi for 14"–24"
fittings. Fittings shall be in accordance with all applicable requirements of ANSI/AWWA C110/
A21.10 or ANSI/AWWA C153/A21.53 with the exception of the manufacturer’s proprietary design
dimensions. Joint components shall be in accordance with the requirements for push-on joints in
ANSI/AWWA C111/A21.11.
*4"–12" sizes are now furnished as TRIM TYTON Fittings. A separate brochure is available
upon request.
®
Note: If specifiers and users believe that corrosive soils will be encountered where our
products are to be installed, please refer to ANSI/AWWA C105/A21.5, Polyethylene Encasement
for Ductile Iron Piping Systems, for proper external protection procedures.
PERMAFUSE ®, TRIM TYTON ®, TYTON ®, TYTON JOINT ®, TR FLEX ® and FIELD LOK 350 ® are
registered trademarks of U.S. Pipe and Foundry Company.
ANSI /AWWA Standards
ANSI/AWWA C110/A21.10, Ductile Iron and
Gray Iron Fittings 3"–48" (75 mm–1200 mm),
for Water.
ANSI/AWWA C153/A21.53, American National
Standard for Ductile Iron Compact Fittings for
Water Service.
ANSI/AWWA C111/A21.11, Rubber Gasket Joints
for Ductile Iron Pressure Pipe and Fittings.
Rubber gasketed push-on joint fittings conform to
and meet all the requirements for push-on joints
in ANSI/AWWA C111/A21.11.Gaskets are normally
furnished with TYTON Fittings.
ASTM A536 "Standard Specification for
Ductile Iron Castings."
Restrained Joints
Instant joint restraint can be obtained for TYTON Fittings and TYTON JOINT® Pipe, sizes 14"–24",
with the use of FIELD LOK 350® Gaskets for 14"–24". With insertion of a FIELD LOK 350 Gasket
joint restraint is provided for maximum working pressure of 350 psi for 14"–24". The FIELD LOK
Gasket systems provide a fast and unique means of joint restraint without the need for thrust
or “kicker” blocks, bolts, grooves, rods, clamps or retainer glands, thus resulting in a savings of
labor, material and time.
CAUTION: U.S. Pipe does not recommend FIELD LOK 350 ® Gaskets for use above ground. The
long-term effect of cyclical movements can be gradual joint separation to the point that the
seal on the gasket bulb is compromised. Sources of cyclical movements include vibration as
may be found on bridge crossings, pressure surges from pumping operations, and thermal
expansion and contraction resulting from atmospheric temperature changes. These conditions
are not experienced with buried pipelines.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
®
Certified to
ANSI/NSF 61
2009
Edition
P4
Assembly of TYTON Fittings
Inspect gasket, socket and spigot for cleanliness. Remove any foreign matter and excessive
coating. When pipe is cut in the field, the cut end can be readily conditioned with a bevel so that
it may be used to make up the joint. The outside of the cut end should be tapered back about
1/4-inch at an angle of about 30 degrees with the center line of the pipe. This can be done quite
easily with a portable grinder. Remove any sharp, rough edges which might injure the gasket.
Insert the TYTON® Gasket into the bell socket, large or bulb end of the gasket entering first. A
small loop or V-shaped fold in the gasket will facilitate its entry. For sizes 14"-24", it may be
helpful to loop the gasket two or more times. Check that the heel of the gasket is uniformly
seated and does not protrude above the bell throat into the pipe way. A thin film of TYTON JOINT®
Lubricant should be applied to the inside surface of the gasket which will come in contact with
the beveled end of the pipe. In warm, dry weather conditions, the lubricant can dry out, especially
when applied to warm or hot pipe, it will be necessary to add a small amount of water to hydrate
the lubricant. Only TYTON JOINT Lubricant should be used.
CAUTION: The use of spray-on lubricant is not recommended. Experience has determined
that spray-on lubricant may not have sufficient lubricity to allow joint assembly without
gasket displacement.
The plain end of the pipe must be cleaned of all foreign matter on the outside from the end to
the stripes. Frozen materials may cling to the pipe in cold weather and must be removed. Apply
a thin film of lubricant to the outside of the plain end for about 3 inches back from the end. Do
not allow the plain end to touch the ground or trench side after lubricating since foreign matter
may adhere to the lubricant and cause a leak. Lubricant other than that furnished with the pipe
should not be used.
The fitting and the pipe must be aligned and the spigot entered into the socket until it just
makes contact with the gasket. This is the starting position for the assembly of the joint.
Joint assembly should then be continued by forcing the spigot of the entering pipe past the
gasket (which is thereby compressed) until the first painted stripe has disappeared into the
socket and the front edge of the second stripe is approx­imately flush with the bell face. If the
assembly is not accomplished with the application of reasonable force, the plain end of the
pipe should be removed to check for the proper positioning of the gasket. Keep the joint in
alignment during assembly.
A feeler gage may be inserted between the bell and the plain end of the assembled joint to verify
the position of the gasket. When the gage encounters the gasket, increased resistance will be
felt. Note the depth of insertion of the gage. Continue probing around the periphery of the joint,
noting the depth to resistance each time. If the depth of insertion is uniform, the gasket has
remained in place. If, at any point, the depth of insertion increases significantly, this indicates a
dislodged gasket. The joint should be disassembled, thoroughly cleaned with water, and examined
for any condition that might have caused the gasket to become dislodged before attempting to
reassemble the joint.
NOTE: Care must be taken not to damage
products furnished with special coatings or
polyethylene encasement.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
®
Certified to
ANSI/NSF 61
2009
P5
Edition
Assembly of TYTON Fittings (cont.)
Tools needed for assembly of 14"-24" TYTON Fittings:
The photograph to the right shows assembly tools if the installer prefers to use come-alongs to
assemble 14"–24" fittings.
Two (2) 1-1/2 ton chain hoists with 25 feet of chain, two (2) bell choker slings of the size
indicated in the table to the right.
Some installers may prefer assembling TYTON Fittings with a backhoe. If this is done, care should
be taken not to damage the gasket, pipe or fitting. A timber between the backhoe bucket and the
fitting will help to prevent such damage. Caution: Avoid “slamming” the fitting home to prevent
damage to lining material inside the bell at the back of the socket.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
SIZE
Bell Choker Sling
Inches
Inches
14 –20
3/8 Dia x 84 long
24
3/8 Dia x 120 long
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
2009
®
Certified to
ANSI/NSF 61
Edition
P6
Bell Dimensions
B
Sizes 14"–24"
Size
Inches
Dimensions
Inches
Size
A
B
1418.12 5.00
1620.32 5.00
1822.52 5.00
2024.74 5.00
2430.14 5.00
NOTE: For Bell Dimensions of TYTON JOINT ® Pipe, reference U.S. Pipe’s TYTON JOINT Pipe Brochure.
Actual bell configuration may vary from illustration shown.
For 12" and smaller fittings of this configuration, please reference U.S. Pipe’s TRIM TYTON ® Fittings brochure.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
®
Certified to
ANSI/NSF 61
2009
Edition
P7
Thicknesses and Dimensions — 90° Bends
14"–24"
Size
Inches
DimensionsWeight
Pressure
InchesPounds
Rating
psi T A RBxB
14
350 0.66 14.0011.50 330
16
350 0.70 15.0012.50 420
18
350 0.75 16.5014.00 520
20
350 0.80 14.0012.38 560
24
350 0.89 17.0014.38 828
NOTE: For 12" and smaller fittings of this configuration, please reference U.S. Pipe’s TRIM TYTON ® Fittings brochure.
*For higher pressure ratings, consult your U.S. Pipe Sales Representative.
Actual bell configuration may vary from illustration shown.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
®
Certified to
ANSI/NSF 61
2009
Edition
P8
Thicknesses and Dimensions — 45° Bends
14"–24"
Size
Inches
Dimensions Weight
Pressure
InchesPounds
Rating
psi T A RBxB
14
350 0.66 7.50 12.06265
16
350 0.70 8.00 13.25330
18
350 0.75 8.50 14.50400
20
350 0.80 9.50 16.88505
24
350 0.89 6.00 14.00536
NOTE: For 12" and smaller fittings of this configuration, please reference U.S. Pipe’s TRIM TYTON ® Fittings brochure.
*For higher pressure ratings, consult your U.S. Pipe Sales Representative.
Actual bell configuration may vary from illustration shown.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
2009
®
Certified to
ANSI/NSF 61
Edition
P9
Thicknesses and Dimensions — 22-1/2° Bends
14"– 24"
Size
Inches
DimensionsWeight
Pressure
InchesPounds
Rating
psi T AR BxB
14
350 0.66 7.5025.12 265
16
350 0.70 8.0027.62 335
18
350 0.75 8.5030.19 405
20
350 0.80 9.5035.19 510
24
350 0.89 4.5014.45 493
NOTE: For 12" and smaller fittings of this configuration, please reference U.S. Pipe’s TRIM TYTON ® Fittings brochure.
*For higher pressure ratings, consult your U.S. Pipe Sales Representative.
Actual bell configuration may vary from illustration shown.
Thicknesses and Dimensions — 30° Bends
Size
Inches
DimensionsWeight
Pressure
InchesPounds
Rating
T
A RBxB
psi
24 350
0.89 8.0021.01 613
*For higher pressure ratings, consult your U.S. Pipe Sales Representative.
Actual bell configuration may vary from illustration shown.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
®
Certified to
ANSI/NSF 61
2009
Edition
P 10
Thicknesses and Dimensions — 11-1/4° Bends
14"– 24"
Size
Inches
DimensionsWeight
Pressure
InchesPounds
Rating
psi T A RBxB
14
350 0.667.50 50.75270
16
350 0.708.00 55.81340
18
350 0.758.50 60.94405
20
350 0.809.50 71.06515
24
350 0.893.00 13.96440
NOTE: For 12" and smaller fittings of this configuration, please reference U.S. Pipe’s TRIM TYTON ® Fittings brochure.
*For higher pressure ratings, consult your U.S. Pipe Sales Representative.
Actual bell configuration may vary from illustration shown.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
®
Certified to
ANSI/NSF 61
2009
Edition
P 11
Thicknesses and Dimensions — 5-5/8° Bends
16" - 24"
Size
Inches
DimensionsWeight
Pressure
InchesPounds
Rating
psi T A RBxB
16 350 0.70 6.0060.00 280
20 350 0.80 5.0057.59 395
24 350 0.89 6.0073.87 547
*For higher pressure ratings, consult your U.S. Pipe Sales Representative.
Actual bell configuration may vary from illustration shown.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
2009
®
Certified to
ANSI/NSF 61
P 12
Edition
Thicknesses and Dimensions — Tees and Crosses
Pressure
Size
Rating
Dimensions
Inches
psi
Inches
Run BranchTT H
1
J S
WEIGHT
Pounds
TeesCrosses
RBxBxBBxBxBxB
146
350 0.66 0.55 14.00 14.0022.00 4.0 405 440
148
350 0.66 0.60 14.00 14.0022.00 4.0 420 470
1410 350 0.66 0.68 14.00 14.0022.00 4.0 435 500
1412 350 0.66 0.75 14.00 14.0022.00 4.0 460 550
14
14 350 0.66 0.66 14.00 14.0022.00 4.0 470 570
166
350 0.70 0.55 15.00 15.0023.00 4.0 505 540
168
350 0.70 0.60 15.00 15.0023.00 4.0 520 570
1610 350 0.70 0.68 15.00 15.0023.00 4.0 535 600
1612 350 0.70 0.75 15.00 15.0023.00 4.0 555 640
1614 350 0.70 0.66 15.00 15.0023.00 4.0 575 680
16
16 350 0.70 0.70 15.00 15.0023.00 4.0 590 710
186
350 0.75 0.55 13.00 15.5021.00 4.0 540 575
188
350 0.75 0.60 13.00 15.5021.00 4.0 555 605
18
10 350 0.75 0.68 13.00 15.5021.00 4.0 570 635
1812 350 0.75 0.75 13.00 15.5021.00 4.0 590 675
1814 350 0.75 0.66 16.50 16.5024.50 4.0 695 805
1816 350 0.75 0.70 16.50 16.5024.50 4.0 715 845
1818 350 0.75 0.75 16.50 16.5024.50 4.0 725 865
NOTE: Flanged outlets can be furnished on a variety of TYTON® Tees. Contact your U.S. Pipe Sales Representative for availability.
*For higher pressure ratings, consult your U.S. Pipe Sales Representative.
Actual bell configuration may vary from illustration shown.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
2009
®
Certified to
ANSI/NSF 61
P 13
Edition
Thicknesses and Dimensions — Tees and Crosses (cont.)
Size
Inches
Pressure
Rating
Dimensions
psi
Inches
Run BranchTT H
1
WEIGHT
Pounds
TeesCrosses
J
S
RBxBxBBxBxBxB
206 350 0.800.5511.016.019.003.5 585 615
208 350 0.800.6011.016.019.003.5 595 635
2010 350 0.800.6811.016.019.003.5 610 665
2012 350 0.800.7511.016.019.003.5 630 705
2014 350 0.800.6614.017.022.004.0 735 835
2016 350 0.800.70 15.015.0 — 2.5 765 870
2018 350 0.800.7518.018.026.004.0 8901040
2020 350 0.800.80 15.015.0 — 2.5 790 920
246 350 0.890.5515.019.023.002.5 900 880
24
8 350 0.890.6015.019.023.002.5 865 910
2410 350 0.890.6815.019.023.002.5 880 940
24
12 350 0.890.7515.019.023.002.5 944 970
2414 350 0.890.6615.019.023.002.5 9151010
2416 350 0.890.7015.019.023.002.5 9351050
2418 350 0.890.7517.021.025.002.510451200
2420 350 0.890.8017.021.025.002.510751260
2424 350 0.890.8917.021.025.002.511991280
NOTE: Flanged outlets can be furnished on a variety of TYTON ® Tees. Contact your U.S. Pipe Sales Representative for availability.
*For higher pressure ratings, consult your U.S. Pipe Sales Representative.
Actual bell configuration may vary from illustration shown.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
2009
®
Certified to
ANSI/NSF 61
Edition
P 14
Thicknesses and Dimensions — Flanged Outlet Tees
Size DimensiONS
Inches
Inches Run BranchH
J
WEIGHT
Pounds
R
146
14.0014.00 4.0 400
148 14.0014.00 4.0 413
1410 14.0014.00 4.0 427
1412
14.0014.00 4.0 457
14
14 14.0014.00 4.0 461
16
6
168
15.00
15.004.0 500
15.00
15.004.0 513
15.004.0 527
1610
15.00
1612
15.0015.00 4.0 552
16
14
15.0015.00 4.0 566
16
16
15.0015.00 4.0 582
186
13.00
15.504.0 535
188
13.00
15.504.0 548
1810
13.00
15.504.0 562
1812
13.0015.50 4.0 587
18
14
16.00
16.504.0 686
18
16
16.00
16.504.0 707
1818
16.00
16.504.0 707
NOTE: Flanged outlets can be furnished on a variety of TYTON ® Tees.
Contact your U.S. Pipe Sales Representative for availability.
*For higher pressure ratings, consult your U.S. Pipe Sales Representative.
Actual bell configuration may vary from illustration shown.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
2009
®
Certified to
ANSI/NSF 61
P 15
Edition
Thicknesses and Dimensions — Flanged Outlet Tees (cont.)
Size DimensiONS
Inches
Inches Run BranchH
206
J
WEIGHT
Pounds
R
11.00
17.003.5 580
208
11.00
17.003.5 588
2010
11.00
17.003.5 602
20
12
11.00­—
20
14
14.00
17.004.0 726
3.5
627
2016
15.00
18.002.5 757
2018
18.00
18.004.0 872
2020
15.00
18.002.5 778
246
15.00
19.002.5 894
248
15.00
19.002.5 858
2410
15.00
19.002.5 872
2412
15.00
19.002.5 940
24
14
15.00
19.002.5 906
24
16
15.00
19.002.5 927
2418
17.00
22.002.5 1027
2420
17.00
22.002.5 1063
24224
17.00
22.002.5 1167
NOTE: Flanged outlets can be furnished on a variety of TYTON ® Tees.
Contact your U.S. Pipe Sales Representative for availability.
*For higher pressure ratings, consult your U.S. Pipe Sales Representative.
Actual bell configuration may vary from illustration shown.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
®
Certified to
ANSI/NSF 61
2009
Edition
P 16
Thicknesses and Dimensions
Bell x Bell Concentric Reducers, 14"–24"
Pressure
Weight
Size
Rating
Dimensions
Pounds
Inches
Inches
psi
Large End
Small EndTT1L
146 350 0.660.55 16 180
148 350 0.660.60 16 200
1410 350 0.660.68 16 225
1412 350 0.660.75 16 250
166 350 0.700.55 18 225
168 350 0.700.60 18 245
1610 350 0.700.68 18 270
1612 350 0.700.75 18 300
1614 350 0.700.66 18 325
188 350 0.750.60 19 285
18
10 350 0.750.68 19 310
1812 350 0.750.75 19 340
18
14 350 0.750.66 19 365
1816 350 0.750.70 19 395
2010 350 0.800.68 20 360
2012 350 0.800.75 20 390
2014 350 0.800.66 20 415
2016 350 0.800.70 20 450
2018 350 0.800.75 20 485
2412 350 0.890.75 24 500
2414 350 0.890.66 24 525
2416 350 0.890.70 24 565
24
18 350 0.890.75 24 600
2420 350 0.890.80 24 645
NOTE: * For higher pressure ratings, consult your U.S. Pipe Sales Representative.
Actual bell configuration may vary from illustration shown.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
®
Certified to
ANSI/NSF 61
2009
Edition
P 17
Thicknesses and Dimensions – Large End Bell
and Small End Bell Concentric Reducers, 14"–24"
LEBxSES
SEBxLES
Pressure
Size
Rating
Dimensions
Inches
psi
Inches
Large End
LEBxSESSEBxLES
WeightWeight
Pounds
Pounds
Small EndTT1L
14
6 350 0.660.55 24 185 165
148 350 0.660.60 24 205 190
1410 350 0.660.68 24 230 210
1412 350 0.660.75 24 260 230
166 350 0.700.55 26 225 205
168 350 0.700.60 26 250 230
1610 350 0.700.68 26 280 250
16
12 350 0.700.75 26 310 280
1614 350 0.700.66 26 310 305
188 350 0.750.60 27 285 270
1810 350 0.750.68 27 315 295
18
12 350 0.750.75 27 350 320
1814 350 0.750.66 27 350 345
1816 350 0.750.70 27 380 380
2010 350 0.800.68 28 370 340
20
12 350 0.800.75 28 400 370
2014 350 0.800.66 28 405 395
2016 350 0.800.70 28 430 430
20
U.S. PIPE AND FOUNDRY CO.
18 350 0.800.75 28 465 460
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
2009
®
Certified to
ANSI/NSF 61
Edition
P 18
Thicknesses and Dimensions – Large End Bell
and Small End Bell Concentric Reducers, 14"–24" (cont.)
Pressure
Size
Rating
Dimensions
Inches
psi
Inches
Large End
Small End
24
LEBxSESSEBxLES
WeightWeight
Pounds
Pounds
psiTT1L
12 350 0.890.75 32 510 500
2414 350 0.890.66 32 510 525
2416 350 0.890.70 32 545 560
24
18 350 0.890.75 32 580 595
2420 350 0.890.80 32 625 645
†Actual weights of fittings may exceed those shown.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
2009
®
Certified to
ANSI/NSF 61
P 19
Edition
TYTON® Plugs
Assembly of the TYTON Plugs can be made as follows:
1. Before the plug is installed adjust all of the set-screws so that screw tips are flush with the
outside diameter of the plug.
2. After the plug is assembled into the socket, tighten each set-screw approximately three (3)
complete turns. This applies to all sizes 4"–24". Excessive tightening of the set-screws should
be avoided.
3. It is important that the plug be installed completely into the socket of TYTON JOINT® Pipe
so that the set-screws are positioned behind the socket throat before the set-screws
are tightened.
It should be noted that the set-screws will make an indentation in the heel of the
TYTON® Gasket, however, this will not harm the function of the gasket in sealing the joint. If the
plug is removed and the line extended at a later date, a new gasket should be used.
Use of a FIELD LOK 350® Gasket with a TYTON® Plug is not supported by U.S. Pipe & Foundry
Company. Diassembly is impossible.
Size
Inches
Pressure Rating
(Set-Screws Provide Restraint)
psi
Dimensions
Inches
A
B
C
NOTE: Actual bell configuration may
vary from illustration shown.
Set-Screws DimenSIONS
Inches
Weight
Pounds
D Length SizeNumber
14
250
15.307-13/163-5/8 1-1/4 2-1/4
7/8
10
130
16
250
17.40 7-1/16 3-5/8 1-5/162-1/4
7/8
10
165
18
250
19.507-1/803-5/8 1-3/82-1/4 7/8
12 205
20
250
21.60 7-3/16 3-5/8 1-7/162-1/4
7/8
14
245
24
250
25.80 7-5/16 3-5/8 1-9/162-1/4
7/8
16
345
NOTE: For 12" and smaller of this configuration, please see U.S. Pipe’s TRIM TYTON ® Fittings Catalog.
†Actual weights of fittings may exceed those shown.
CAPS: Caps are not available for TYTON JOINT ® Pipe. TR FLEX ® Caps can be used with TYTON JOINT Pipe when required. Reference U.S.Pipe’s TR FLEX ®
Restrained Joint Ductile Iron Pipe and Fittings. brochure.
The function of the set-screw on sizes 14"–24" in locking the plug in a socket of TYTON JOINT Pipe is not dependent on how tightly the screws are applied, but
rather on how far the screws are advanced in order that they will lock behind the socket throat.
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
REVISED 03.09
866.DIP.PIPE
TYTON Fittings
®
NSF
2009
®
Certified to
ANSI/NSF 61
Edition
P 20
Products for Water, Wastewater and Fire Protection
ductile iron Pipe
siZE ranGE
TYTON JOINT® Pipe
4"-64" Ductile Iron
Mechanical Joint Pipe
4"-12" Ductile Iron
TR FLEX® Pipe
4"-36" Ductile Iron
HP LOK Pipe
30"-64" Ductile Iron
Flanged Pipe
3"-64" Ductile Iron
®
Grooved Pipe
4”-36” Ductile Iron
USIFLEX® Boltless Ball Joint Pipe
For Subaqueous Installations
4"-48" Ductile Iron
restrained Joints
TR FLEX® Restrained Joint
4"-36" Ductile Iron
HP LOK® Restrained Joint
30"-64" Ductile Iron
MJ FIELD LOK Gaskets
4"-24"
FIELD LOK 350® Gaskets
4"-24"
FIELD LOK® Gasket
30" & 36"
TR FLEX GRIPPER® Rings
4"-36" Ductile Iron
TR TELE FLEX Assemblies
4"-24" Ductile Iron
®
®
fittings
TYTON® Fittings
14"-24" Ductile Iron
TRIM TYTON Fittings
4”-12” Ductile Iron
®
TR FLEX Fittings and TR FLEX Telescoping Sleeves
4"-36" Ductile Iron
HP LOK® Fittings and HP LOK® Telescoping Sleeves
30”-64” Ductile Iron
Mechanical Joint Fittings
30"-48" Ductile Iron
Flanged Fittings
30"-64" Ductile Iron
XTRA FLEX Couplings
4"-24" Ductile Iron
®
®
®
Miscellaneous Products
PROTECTO 401™ Lined Ductile Iron Pipe for
Domestic Sewage and Industrial Wastes
4"-64" Ductile Iron
GLASS Lined Ductile Iron Pipe for Wastewater
Treatment Plants
4”-30” Ductile Iron
RING FLANGE-TYTE® Gaskets
4"-36"
FULL FACE FLANGE-TYTE® Gaskets
4"-64"
MJ Harness-Lok
4”-48” Ductile Iron
Saddle Outlets
Various Ductile Iron
Welded Outlets
Various Ductile Iron
Polyethylene Encasement
4"-64"
U.S. PIPE AND FOUNDRY CO.
TYTON® Fittings BRO-004
Our products are manufactured in conformance
with National Standards so that our customers
may be assured of getting the performance and
longevity they expect. Use of accessories or
other appurtenances that do not comply with
recognized standards may jeopardize the
performance and longevity of the project.
REVISED 03.09
All U.S. Pipe brochures and/or products are
subject to change without further notice.
P.o. BoX 10406
BIRMINGhAM, AL 35202
866.DIP.PIPE (866.347.7473)
FAX: 205.254.7165
EMAIL: INFo@USPIPE.CoM
WWW.USPIPE.CoM
Download