2 0 0 9 E d i t i o n Tyton fittings ® 14"-24" NSF ® Certified to ANSI/NSF 61 For Water & Wastewater, Fire Protection & Industrial Applications 866.DIP.PIPE TYTON Fittings ® NSF 2009 ® Certified to ANSI/NSF 61 Edition P2 Table of Contents TYTON Fittings 3 Assembly of TYTON Fittings 4 Bell Dimensions 6 Thickness and Dimensions 90° Bends 45° Bends 22-1/2° Bends 30° Bends 11-1/4° Bends 5-5/8° Bends Tees and Crosses Flanged Outlet Tees Bell x Bell Concentric Reducers, 14"-24" Large End Bell and Small End Bell Concentric Reducers, 14"-24" TYTON Plugs Products for Water, Waste Water, and Fire Protection U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 7 8 9 9 10 11 12 14 16 17 19 20 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF 2009 ® Certified to ANSI/NSF 61 Edition P3 TYTON Fittings TYTON JOINT® Pipe (push-on) has become so popular since its introduction in 1956 that it now constitutes more than 95% of the pipe shipped by U.S. Pipe. In 1965, U.S. Pipe introduced 4"–12"* TYTON® Fittings. Later, U.S. Pipe introduced 14"–24". TYTON Fittings are also produced in metric diameters for the international market. (See U.S. Pipe’s International Catalog.) Fittings shall be push-on joint Ductile Iron fittings with a pressure rating of 350 psi for 14"–24" fittings. Fittings shall be in accordance with all applicable requirements of ANSI/AWWA C110/ A21.10 or ANSI/AWWA C153/A21.53 with the exception of the manufacturer’s proprietary design dimensions. Joint components shall be in accordance with the requirements for push-on joints in ANSI/AWWA C111/A21.11. *4"–12" sizes are now furnished as TRIM TYTON Fittings. A separate brochure is available upon request. ® Note: If specifiers and users believe that corrosive soils will be encountered where our products are to be installed, please refer to ANSI/AWWA C105/A21.5, Polyethylene Encasement for Ductile Iron Piping Systems, for proper external protection procedures. PERMAFUSE ®, TRIM TYTON ®, TYTON ®, TYTON JOINT ®, TR FLEX ® and FIELD LOK 350 ® are registered trademarks of U.S. Pipe and Foundry Company. ANSI /AWWA Standards ANSI/AWWA C110/A21.10, Ductile Iron and Gray Iron Fittings 3"–48" (75 mm–1200 mm), for Water. ANSI/AWWA C153/A21.53, American National Standard for Ductile Iron Compact Fittings for Water Service. ANSI/AWWA C111/A21.11, Rubber Gasket Joints for Ductile Iron Pressure Pipe and Fittings. Rubber gasketed push-on joint fittings conform to and meet all the requirements for push-on joints in ANSI/AWWA C111/A21.11.Gaskets are normally furnished with TYTON Fittings. ASTM A536 "Standard Specification for Ductile Iron Castings." Restrained Joints Instant joint restraint can be obtained for TYTON Fittings and TYTON JOINT® Pipe, sizes 14"–24", with the use of FIELD LOK 350® Gaskets for 14"–24". With insertion of a FIELD LOK 350 Gasket joint restraint is provided for maximum working pressure of 350 psi for 14"–24". The FIELD LOK Gasket systems provide a fast and unique means of joint restraint without the need for thrust or “kicker” blocks, bolts, grooves, rods, clamps or retainer glands, thus resulting in a savings of labor, material and time. CAUTION: U.S. Pipe does not recommend FIELD LOK 350 ® Gaskets for use above ground. The long-term effect of cyclical movements can be gradual joint separation to the point that the seal on the gasket bulb is compromised. Sources of cyclical movements include vibration as may be found on bridge crossings, pressure surges from pumping operations, and thermal expansion and contraction resulting from atmospheric temperature changes. These conditions are not experienced with buried pipelines. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF ® Certified to ANSI/NSF 61 2009 Edition P4 Assembly of TYTON Fittings Inspect gasket, socket and spigot for cleanliness. Remove any foreign matter and excessive coating. When pipe is cut in the field, the cut end can be readily conditioned with a bevel so that it may be used to make up the joint. The outside of the cut end should be tapered back about 1/4-inch at an angle of about 30 degrees with the center line of the pipe. This can be done quite easily with a portable grinder. Remove any sharp, rough edges which might injure the gasket. Insert the TYTON® Gasket into the bell socket, large or bulb end of the gasket entering first. A small loop or V-shaped fold in the gasket will facilitate its entry. For sizes 14"-24", it may be helpful to loop the gasket two or more times. Check that the heel of the gasket is uniformly seated and does not protrude above the bell throat into the pipe way. A thin film of TYTON JOINT® Lubricant should be applied to the inside surface of the gasket which will come in contact with the beveled end of the pipe. In warm, dry weather conditions, the lubricant can dry out, especially when applied to warm or hot pipe, it will be necessary to add a small amount of water to hydrate the lubricant. Only TYTON JOINT Lubricant should be used. CAUTION: The use of spray-on lubricant is not recommended. Experience has determined that spray-on lubricant may not have sufficient lubricity to allow joint assembly without gasket displacement. The plain end of the pipe must be cleaned of all foreign matter on the outside from the end to the stripes. Frozen materials may cling to the pipe in cold weather and must be removed. Apply a thin film of lubricant to the outside of the plain end for about 3 inches back from the end. Do not allow the plain end to touch the ground or trench side after lubricating since foreign matter may adhere to the lubricant and cause a leak. Lubricant other than that furnished with the pipe should not be used. The fitting and the pipe must be aligned and the spigot entered into the socket until it just makes contact with the gasket. This is the starting position for the assembly of the joint. Joint assembly should then be continued by forcing the spigot of the entering pipe past the gasket (which is thereby compressed) until the first painted stripe has disappeared into the socket and the front edge of the second stripe is approx­imately flush with the bell face. If the assembly is not accomplished with the application of reasonable force, the plain end of the pipe should be removed to check for the proper positioning of the gasket. Keep the joint in alignment during assembly. A feeler gage may be inserted between the bell and the plain end of the assembled joint to verify the position of the gasket. When the gage encounters the gasket, increased resistance will be felt. Note the depth of insertion of the gage. Continue probing around the periphery of the joint, noting the depth to resistance each time. If the depth of insertion is uniform, the gasket has remained in place. If, at any point, the depth of insertion increases significantly, this indicates a dislodged gasket. The joint should be disassembled, thoroughly cleaned with water, and examined for any condition that might have caused the gasket to become dislodged before attempting to reassemble the joint. NOTE: Care must be taken not to damage products furnished with special coatings or polyethylene encasement. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF ® Certified to ANSI/NSF 61 2009 P5 Edition Assembly of TYTON Fittings (cont.) Tools needed for assembly of 14"-24" TYTON Fittings: The photograph to the right shows assembly tools if the installer prefers to use come-alongs to assemble 14"–24" fittings. Two (2) 1-1/2 ton chain hoists with 25 feet of chain, two (2) bell choker slings of the size indicated in the table to the right. Some installers may prefer assembling TYTON Fittings with a backhoe. If this is done, care should be taken not to damage the gasket, pipe or fitting. A timber between the backhoe bucket and the fitting will help to prevent such damage. Caution: Avoid “slamming” the fitting home to prevent damage to lining material inside the bell at the back of the socket. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 SIZE Bell Choker Sling Inches Inches 14 –20 3/8 Dia x 84 long 24 3/8 Dia x 120 long REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF 2009 ® Certified to ANSI/NSF 61 Edition P6 Bell Dimensions B Sizes 14"–24" Size Inches Dimensions Inches Size A B 1418.12 5.00 1620.32 5.00 1822.52 5.00 2024.74 5.00 2430.14 5.00 NOTE: For Bell Dimensions of TYTON JOINT ® Pipe, reference U.S. Pipe’s TYTON JOINT Pipe Brochure. Actual bell configuration may vary from illustration shown. For 12" and smaller fittings of this configuration, please reference U.S. Pipe’s TRIM TYTON ® Fittings brochure. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF ® Certified to ANSI/NSF 61 2009 Edition P7 Thicknesses and Dimensions — 90° Bends 14"–24" Size Inches DimensionsWeight Pressure InchesPounds Rating psi T A RBxB 14 350 0.66 14.0011.50 330 16 350 0.70 15.0012.50 420 18 350 0.75 16.5014.00 520 20 350 0.80 14.0012.38 560 24 350 0.89 17.0014.38 828 NOTE: For 12" and smaller fittings of this configuration, please reference U.S. Pipe’s TRIM TYTON ® Fittings brochure. *For higher pressure ratings, consult your U.S. Pipe Sales Representative. Actual bell configuration may vary from illustration shown. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF ® Certified to ANSI/NSF 61 2009 Edition P8 Thicknesses and Dimensions — 45° Bends 14"–24" Size Inches Dimensions Weight Pressure InchesPounds Rating psi T A RBxB 14 350 0.66 7.50 12.06265 16 350 0.70 8.00 13.25330 18 350 0.75 8.50 14.50400 20 350 0.80 9.50 16.88505 24 350 0.89 6.00 14.00536 NOTE: For 12" and smaller fittings of this configuration, please reference U.S. Pipe’s TRIM TYTON ® Fittings brochure. *For higher pressure ratings, consult your U.S. Pipe Sales Representative. Actual bell configuration may vary from illustration shown. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF 2009 ® Certified to ANSI/NSF 61 Edition P9 Thicknesses and Dimensions — 22-1/2° Bends 14"– 24" Size Inches DimensionsWeight Pressure InchesPounds Rating psi T AR BxB 14 350 0.66 7.5025.12 265 16 350 0.70 8.0027.62 335 18 350 0.75 8.5030.19 405 20 350 0.80 9.5035.19 510 24 350 0.89 4.5014.45 493 NOTE: For 12" and smaller fittings of this configuration, please reference U.S. Pipe’s TRIM TYTON ® Fittings brochure. *For higher pressure ratings, consult your U.S. Pipe Sales Representative. Actual bell configuration may vary from illustration shown. Thicknesses and Dimensions — 30° Bends Size Inches DimensionsWeight Pressure InchesPounds Rating T A RBxB psi 24 350 0.89 8.0021.01 613 *For higher pressure ratings, consult your U.S. Pipe Sales Representative. Actual bell configuration may vary from illustration shown. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF ® Certified to ANSI/NSF 61 2009 Edition P 10 Thicknesses and Dimensions — 11-1/4° Bends 14"– 24" Size Inches DimensionsWeight Pressure InchesPounds Rating psi T A RBxB 14 350 0.667.50 50.75270 16 350 0.708.00 55.81340 18 350 0.758.50 60.94405 20 350 0.809.50 71.06515 24 350 0.893.00 13.96440 NOTE: For 12" and smaller fittings of this configuration, please reference U.S. Pipe’s TRIM TYTON ® Fittings brochure. *For higher pressure ratings, consult your U.S. Pipe Sales Representative. Actual bell configuration may vary from illustration shown. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF ® Certified to ANSI/NSF 61 2009 Edition P 11 Thicknesses and Dimensions — 5-5/8° Bends 16" - 24" Size Inches DimensionsWeight Pressure InchesPounds Rating psi T A RBxB 16 350 0.70 6.0060.00 280 20 350 0.80 5.0057.59 395 24 350 0.89 6.0073.87 547 *For higher pressure ratings, consult your U.S. Pipe Sales Representative. Actual bell configuration may vary from illustration shown. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF 2009 ® Certified to ANSI/NSF 61 P 12 Edition Thicknesses and Dimensions — Tees and Crosses Pressure Size Rating Dimensions Inches psi Inches Run BranchTT H 1 J S WEIGHT Pounds TeesCrosses RBxBxBBxBxBxB 146 350 0.66 0.55 14.00 14.0022.00 4.0 405 440 148 350 0.66 0.60 14.00 14.0022.00 4.0 420 470 1410 350 0.66 0.68 14.00 14.0022.00 4.0 435 500 1412 350 0.66 0.75 14.00 14.0022.00 4.0 460 550 14 14 350 0.66 0.66 14.00 14.0022.00 4.0 470 570 166 350 0.70 0.55 15.00 15.0023.00 4.0 505 540 168 350 0.70 0.60 15.00 15.0023.00 4.0 520 570 1610 350 0.70 0.68 15.00 15.0023.00 4.0 535 600 1612 350 0.70 0.75 15.00 15.0023.00 4.0 555 640 1614 350 0.70 0.66 15.00 15.0023.00 4.0 575 680 16 16 350 0.70 0.70 15.00 15.0023.00 4.0 590 710 186 350 0.75 0.55 13.00 15.5021.00 4.0 540 575 188 350 0.75 0.60 13.00 15.5021.00 4.0 555 605 18 10 350 0.75 0.68 13.00 15.5021.00 4.0 570 635 1812 350 0.75 0.75 13.00 15.5021.00 4.0 590 675 1814 350 0.75 0.66 16.50 16.5024.50 4.0 695 805 1816 350 0.75 0.70 16.50 16.5024.50 4.0 715 845 1818 350 0.75 0.75 16.50 16.5024.50 4.0 725 865 NOTE: Flanged outlets can be furnished on a variety of TYTON® Tees. Contact your U.S. Pipe Sales Representative for availability. *For higher pressure ratings, consult your U.S. Pipe Sales Representative. Actual bell configuration may vary from illustration shown. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF 2009 ® Certified to ANSI/NSF 61 P 13 Edition Thicknesses and Dimensions — Tees and Crosses (cont.) Size Inches Pressure Rating Dimensions psi Inches Run BranchTT H 1 WEIGHT Pounds TeesCrosses J S RBxBxBBxBxBxB 206 350 0.800.5511.016.019.003.5 585 615 208 350 0.800.6011.016.019.003.5 595 635 2010 350 0.800.6811.016.019.003.5 610 665 2012 350 0.800.7511.016.019.003.5 630 705 2014 350 0.800.6614.017.022.004.0 735 835 2016 350 0.800.70 15.015.0 — 2.5 765 870 2018 350 0.800.7518.018.026.004.0 8901040 2020 350 0.800.80 15.015.0 — 2.5 790 920 246 350 0.890.5515.019.023.002.5 900 880 24 8 350 0.890.6015.019.023.002.5 865 910 2410 350 0.890.6815.019.023.002.5 880 940 24 12 350 0.890.7515.019.023.002.5 944 970 2414 350 0.890.6615.019.023.002.5 9151010 2416 350 0.890.7015.019.023.002.5 9351050 2418 350 0.890.7517.021.025.002.510451200 2420 350 0.890.8017.021.025.002.510751260 2424 350 0.890.8917.021.025.002.511991280 NOTE: Flanged outlets can be furnished on a variety of TYTON ® Tees. Contact your U.S. Pipe Sales Representative for availability. *For higher pressure ratings, consult your U.S. Pipe Sales Representative. Actual bell configuration may vary from illustration shown. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF 2009 ® Certified to ANSI/NSF 61 Edition P 14 Thicknesses and Dimensions — Flanged Outlet Tees Size DimensiONS Inches Inches Run BranchH J WEIGHT Pounds R 146 14.0014.00 4.0 400 148 14.0014.00 4.0 413 1410 14.0014.00 4.0 427 1412 14.0014.00 4.0 457 14 14 14.0014.00 4.0 461 16 6 168 15.00 15.004.0 500 15.00 15.004.0 513 15.004.0 527 1610 15.00 1612 15.0015.00 4.0 552 16 14 15.0015.00 4.0 566 16 16 15.0015.00 4.0 582 186 13.00 15.504.0 535 188 13.00 15.504.0 548 1810 13.00 15.504.0 562 1812 13.0015.50 4.0 587 18 14 16.00 16.504.0 686 18 16 16.00 16.504.0 707 1818 16.00 16.504.0 707 NOTE: Flanged outlets can be furnished on a variety of TYTON ® Tees. Contact your U.S. Pipe Sales Representative for availability. *For higher pressure ratings, consult your U.S. Pipe Sales Representative. Actual bell configuration may vary from illustration shown. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF 2009 ® Certified to ANSI/NSF 61 P 15 Edition Thicknesses and Dimensions — Flanged Outlet Tees (cont.) Size DimensiONS Inches Inches Run BranchH 206 J WEIGHT Pounds R 11.00 17.003.5 580 208 11.00 17.003.5 588 2010 11.00 17.003.5 602 20 12 11.00­— 20 14 14.00 17.004.0 726 3.5 627 2016 15.00 18.002.5 757 2018 18.00 18.004.0 872 2020 15.00 18.002.5 778 246 15.00 19.002.5 894 248 15.00 19.002.5 858 2410 15.00 19.002.5 872 2412 15.00 19.002.5 940 24 14 15.00 19.002.5 906 24 16 15.00 19.002.5 927 2418 17.00 22.002.5 1027 2420 17.00 22.002.5 1063 24224 17.00 22.002.5 1167 NOTE: Flanged outlets can be furnished on a variety of TYTON ® Tees. Contact your U.S. Pipe Sales Representative for availability. *For higher pressure ratings, consult your U.S. Pipe Sales Representative. Actual bell configuration may vary from illustration shown. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF ® Certified to ANSI/NSF 61 2009 Edition P 16 Thicknesses and Dimensions Bell x Bell Concentric Reducers, 14"–24" Pressure Weight Size Rating Dimensions Pounds Inches Inches psi Large End Small EndTT1L 146 350 0.660.55 16 180 148 350 0.660.60 16 200 1410 350 0.660.68 16 225 1412 350 0.660.75 16 250 166 350 0.700.55 18 225 168 350 0.700.60 18 245 1610 350 0.700.68 18 270 1612 350 0.700.75 18 300 1614 350 0.700.66 18 325 188 350 0.750.60 19 285 18 10 350 0.750.68 19 310 1812 350 0.750.75 19 340 18 14 350 0.750.66 19 365 1816 350 0.750.70 19 395 2010 350 0.800.68 20 360 2012 350 0.800.75 20 390 2014 350 0.800.66 20 415 2016 350 0.800.70 20 450 2018 350 0.800.75 20 485 2412 350 0.890.75 24 500 2414 350 0.890.66 24 525 2416 350 0.890.70 24 565 24 18 350 0.890.75 24 600 2420 350 0.890.80 24 645 NOTE: * For higher pressure ratings, consult your U.S. Pipe Sales Representative. Actual bell configuration may vary from illustration shown. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF ® Certified to ANSI/NSF 61 2009 Edition P 17 Thicknesses and Dimensions – Large End Bell and Small End Bell Concentric Reducers, 14"–24" LEBxSES SEBxLES Pressure Size Rating Dimensions Inches psi Inches Large End LEBxSESSEBxLES WeightWeight Pounds Pounds Small EndTT1L 14 6 350 0.660.55 24 185 165 148 350 0.660.60 24 205 190 1410 350 0.660.68 24 230 210 1412 350 0.660.75 24 260 230 166 350 0.700.55 26 225 205 168 350 0.700.60 26 250 230 1610 350 0.700.68 26 280 250 16 12 350 0.700.75 26 310 280 1614 350 0.700.66 26 310 305 188 350 0.750.60 27 285 270 1810 350 0.750.68 27 315 295 18 12 350 0.750.75 27 350 320 1814 350 0.750.66 27 350 345 1816 350 0.750.70 27 380 380 2010 350 0.800.68 28 370 340 20 12 350 0.800.75 28 400 370 2014 350 0.800.66 28 405 395 2016 350 0.800.70 28 430 430 20 U.S. PIPE AND FOUNDRY CO. 18 350 0.800.75 28 465 460 TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF 2009 ® Certified to ANSI/NSF 61 Edition P 18 Thicknesses and Dimensions – Large End Bell and Small End Bell Concentric Reducers, 14"–24" (cont.) Pressure Size Rating Dimensions Inches psi Inches Large End Small End 24 LEBxSESSEBxLES WeightWeight Pounds Pounds psiTT1L 12 350 0.890.75 32 510 500 2414 350 0.890.66 32 510 525 2416 350 0.890.70 32 545 560 24 18 350 0.890.75 32 580 595 2420 350 0.890.80 32 625 645 †Actual weights of fittings may exceed those shown. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF 2009 ® Certified to ANSI/NSF 61 P 19 Edition TYTON® Plugs Assembly of the TYTON Plugs can be made as follows: 1. Before the plug is installed adjust all of the set-screws so that screw tips are flush with the outside diameter of the plug. 2. After the plug is assembled into the socket, tighten each set-screw approximately three (3) complete turns. This applies to all sizes 4"–24". Excessive tightening of the set-screws should be avoided. 3. It is important that the plug be installed completely into the socket of TYTON JOINT® Pipe so that the set-screws are positioned behind the socket throat before the set-screws are tightened. It should be noted that the set-screws will make an indentation in the heel of the TYTON® Gasket, however, this will not harm the function of the gasket in sealing the joint. If the plug is removed and the line extended at a later date, a new gasket should be used. Use of a FIELD LOK 350® Gasket with a TYTON® Plug is not supported by U.S. Pipe & Foundry Company. Diassembly is impossible. Size Inches Pressure Rating (Set-Screws Provide Restraint) psi Dimensions Inches A B C NOTE: Actual bell configuration may vary from illustration shown. Set-Screws DimenSIONS Inches Weight Pounds D Length SizeNumber 14 250 15.307-13/163-5/8 1-1/4 2-1/4 7/8 10 130 16 250 17.40 7-1/16 3-5/8 1-5/162-1/4 7/8 10 165 18 250 19.507-1/803-5/8 1-3/82-1/4 7/8 12 205 20 250 21.60 7-3/16 3-5/8 1-7/162-1/4 7/8 14 245 24 250 25.80 7-5/16 3-5/8 1-9/162-1/4 7/8 16 345 NOTE: For 12" and smaller of this configuration, please see U.S. Pipe’s TRIM TYTON ® Fittings Catalog. †Actual weights of fittings may exceed those shown. CAPS: Caps are not available for TYTON JOINT ® Pipe. TR FLEX ® Caps can be used with TYTON JOINT Pipe when required. Reference U.S.Pipe’s TR FLEX ® Restrained Joint Ductile Iron Pipe and Fittings. brochure. The function of the set-screw on sizes 14"–24" in locking the plug in a socket of TYTON JOINT Pipe is not dependent on how tightly the screws are applied, but rather on how far the screws are advanced in order that they will lock behind the socket throat. U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 REVISED 03.09 866.DIP.PIPE TYTON Fittings ® NSF 2009 ® Certified to ANSI/NSF 61 Edition P 20 Products for Water, Wastewater and Fire Protection ductile iron Pipe siZE ranGE TYTON JOINT® Pipe 4"-64" Ductile Iron Mechanical Joint Pipe 4"-12" Ductile Iron TR FLEX® Pipe 4"-36" Ductile Iron HP LOK Pipe 30"-64" Ductile Iron Flanged Pipe 3"-64" Ductile Iron ® Grooved Pipe 4”-36” Ductile Iron USIFLEX® Boltless Ball Joint Pipe For Subaqueous Installations 4"-48" Ductile Iron restrained Joints TR FLEX® Restrained Joint 4"-36" Ductile Iron HP LOK® Restrained Joint 30"-64" Ductile Iron MJ FIELD LOK Gaskets 4"-24" FIELD LOK 350® Gaskets 4"-24" FIELD LOK® Gasket 30" & 36" TR FLEX GRIPPER® Rings 4"-36" Ductile Iron TR TELE FLEX Assemblies 4"-24" Ductile Iron ® ® fittings TYTON® Fittings 14"-24" Ductile Iron TRIM TYTON Fittings 4”-12” Ductile Iron ® TR FLEX Fittings and TR FLEX Telescoping Sleeves 4"-36" Ductile Iron HP LOK® Fittings and HP LOK® Telescoping Sleeves 30”-64” Ductile Iron Mechanical Joint Fittings 30"-48" Ductile Iron Flanged Fittings 30"-64" Ductile Iron XTRA FLEX Couplings 4"-24" Ductile Iron ® ® ® Miscellaneous Products PROTECTO 401™ Lined Ductile Iron Pipe for Domestic Sewage and Industrial Wastes 4"-64" Ductile Iron GLASS Lined Ductile Iron Pipe for Wastewater Treatment Plants 4”-30” Ductile Iron RING FLANGE-TYTE® Gaskets 4"-36" FULL FACE FLANGE-TYTE® Gaskets 4"-64" MJ Harness-Lok 4”-48” Ductile Iron Saddle Outlets Various Ductile Iron Welded Outlets Various Ductile Iron Polyethylene Encasement 4"-64" U.S. PIPE AND FOUNDRY CO. TYTON® Fittings BRO-004 Our products are manufactured in conformance with National Standards so that our customers may be assured of getting the performance and longevity they expect. Use of accessories or other appurtenances that do not comply with recognized standards may jeopardize the performance and longevity of the project. REVISED 03.09 All U.S. Pipe brochures and/or products are subject to change without further notice. P.o. BoX 10406 BIRMINGhAM, AL 35202 866.DIP.PIPE (866.347.7473) FAX: 205.254.7165 EMAIL: INFo@USPIPE.CoM WWW.USPIPE.CoM