COMPACT FLUORESCENT DOWN LIGHT Project CEILING FIXTURE LEGEND: KEYNOTES: D COMPACT FLUORESCENT DOWN LIGHT DIMMABLE COMPACT FLUORESCENT WALL WASHER W COMPACT FLUORESCENT DOWN LIGHT WET LOCATION SUPPLY AIR REGISTER RETURN AIR GRILLE EF EXHAUST FAN -BROAN 688 SPRINKLER HEAD CEILING HEIGHT 11. REFER TO FINISH LEGEND DROPPED GYPSUM BOARD CEILING/SOFFIT- 3 5/8" MTL STUD FRAMING AT 16" O.C. WITH 5/8" GYP. BD. HEIGHT AS INDICATED AND WIDTH PER PLAN. PROVIDE WATER RESISTANT GYP BOARD AT POOL, BATHROOMS, TOILET ROMS AND OTHER DAMP LOCATIONS 2X2 OR 2X4 LAY IN CEILING GRID- SEE FINISH PLAN. GRID TO BE CENTERED WITHIN ROOM OR SPACE U.O.N. 2. 3. 4. 5. 6. COORDINATE CEILING HEIGHTS, SOFFIT HEIGHTS AND STOREFRONT GLAZING TO ALLOW MINIMUM CEILING HEIGHT AT BREAKFAST AREA PER BRAND STANDARDS CEILING COVE AT BREAKFAST AREA BY DESIGNER OF RECORD (INN AND SUITES ONLY) EXTERIOR GRADE SMOOTH FINISH CEILING AT EXTERIOR VESTIBULE MEETING ROOM LIGHTING TO BE CENTRALLY DIMMER CONTROLLED CEILING RECESS FOR SLIDING DOOR VERTICALLY MOUNTED SUPPLY AIR IN BULKHEAD Hotel Project ref #-08-465 1250 South River Rd. Lot # 5,6, & 10 Block #6 Township of Cranbury, NJ BATTERY BACKED UP EXIT SIGN-PROVIDE COMBINATION EMERGENCY LIGHT/EXIT UNIT AT EXIT DOORS INDICATED WITH EMERGENCY LIGHT FIXTURE Architect EXTERIOR BUILDING MOUNTED DUAL HEAD EMERGENCY LIGHT WITH REMOTE BATTERY BACK UP- MISTRY DESIGN EXTERIOR WALL SCONCE EXTERIOR WALL SCONCE Cranbury Project Location LARGE DECORATIVE HANGING PENDANT SMALL DECORATIVE HANGING PENDANT Hampton Inn 17 Main Street, Suite 100 Netcong, NJ 07857 Tel: 973.347.2727 Fax: 973.347.2261 BATTERY BACKED UP EXIT SIGN EXTERIOR DOWNLIGHT EXTERIOR UP LIGHTING-@ GROUND EXTERIOR UP LIGHTING-@ ROOF PARAPET AND ROOF INTERIOR WALL SCONCE - POOL- WET LOCATION NJ Cert. of Authorization No: 21AC00079600 1X4 FLUORESCENT LIGHT FIXTURE 2X2 FLUORESCENT LIGHT FIXTURE THIS DRAWING ONLY FOR GENERAL CEILING & POWER LAYOUT ONLY- SEE ELECTRICAL DRAWINGS FOR MORE DETAILED INFORMATION 2X4 FLUORESCENT LIGHT FIXTURE GENERAL NOTES: AUDIO EQUIPMENT LEGEND: A W W W W W W W W W W W W W W W W W W W DMX SM 105; TAPPED @ 7.5WATTS, SURFACE SPEAKER - MOUNTED TO EXTERIOR WALL @12' A.F.F.,18AWG 2-CONDUCTOR SPEAKER WIRE DMX, Inc. grouphilton@dmx.com 1-(800) 687-0652 W W W WALL MOUNTED FLUORESCENT LIGHT FIXTURE 1. REFER TO GUEST ROOM CEILING PLANS FOR ADDITIONAL LIGHTING INFORMATION 2. ANY PORTION OF A WALL SCONCE OR OTHER OBJECT THAT PROTRUDES INTO A CIRCULATION PATH ABOVE 27" AND BELOW 80" IS LIMITED TO A 4" MAXIMUM PROJECTION. WALL MOUNTED DECORATIVE SCONCE COMPACT FLUORESCENT DOWN LIGHT VOLUME CONTROL, 1-GANG - MOUNTING HEIGHT @ 48" A.F.F., 18AWG 2-CONDUCTOR SPEAKER WIRE MIC WALL PLATE, 1-GANG - MOUNTING HEIGHT @ 48" A.F.F., 18AWG 2-CON, w/SHIELD WIRE W W FLUORESCENT LIGHT FIXTURE SURFACE MTD W DB REFER TO ENLARGED GUESTROOM CLG. PLANS FOR CLG. INFO. THIS AREA W AUDIO HEADEND,LOWELL FS1820 SHELF IN MANAGER'S OFFICE DMX 6201T; TAPPED @ 7.5 WATTS, FLUSH CEILING SPEAKER, 18AWG 2-CONDUCTOR SPEAKER WIRE DMX, Inc. grouphilton@dmx.com 1-(800) 687-0652 1020 SF W W REFER TO ENLARGED GUESTROOM CLG. PLANS FOR CLG. INFO. THIS AREA Issues and Revisions Issues and Revisions No. Date 1. 07.15.13 FOR 50% HILTON REVIEW 2. 09.13.13 FOR 100% HILTON REVIEW 3. 01.08.14 HILTON REVIEW COMMENTS By Check YM YM YM Registration and Signature Yogesh Mistry NJ License No: AI 14564 Drawing Description: Project Number: Computer File: FIRST FLOOR REFLECTED CEILING PLAN 1164-1 A3.01 Scale Ref.North 1 FIRST FLOOR REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0" A3.01 All drawings and written material appearing herein constitute original and unpublished work of the architect and may not be duplicated, used or disclosed without written consent of the architect. c 2011 MistryDesign LLC. All Rights Reserved