Blood Glucose Management Software User manual Name: DiaLife Mini REV 04 07/16/2015 A9-1 of 23 User Manual I. INTRODUCTION ............................................................................................................... 3 II. SOFTWARE INSTALLATION ................................................................................................ 6 III. START TO USE .................................................................................................................. 17 IV. TROUBLE SHOOTING....................................................................................................... 22 REV 04 07/16/2015 A9-2 of 23 I. Introduction Intended Use: This product is designed for use with DELBio Blood Glucose Monitoring System to help users transmit data from meter to their computer at home. The DiaLife Mini system includes USB Cable and DiaLife Mini application. The USB cable needs cable driver to install your personal computer to connect the computer side and meter side, and the DiaLife Mini can help people to download the data stored in glucose meter to export file to computer hard disk. Manufacturer: DELBio Inc. 3F, No. 252, Shangying Road Guishan Industrial Zone Taoyuan County 33341, Taiwan, R.O.C. If you have any questions regarding this product, please contact: 1-855-9DELBIO or 1-855-933-5246, 9 AM to 5 PM, M-F EST. The users should contact their healthcare professionals at other times. www.delbio.com.tw Warning: Please read this manual carefully before use. Warning: The installation manual includes USB cable driver and DiaLife Mini installation; please follow the process of this manual. Warning: Please download the following two drivers software in your PC from DELBio website: http://www.delbio.com.tw/download/ DiaLife Mini setup file includes: * DiaLife Mini application installer * Cable Driver installer Warning: Do not test blood glucose when the glucose meter links to PC. Warning: Please install cable driver and DiaLife Mini before connecting cable REV 04 07/16/2015 A9-3 of 23 for transmission. Warning: The DiaLife Mini shall only be as a personal use. Warning: Do not modify the exported data, the test records should only be used as a reference. DiaLife mini Main Features: Download test records from blood glucose meter via cable. Export download data to CSV format file and save to PC disk. REV 04 07/16/2015 A9-4 of 23 DiaLife Mini Overview: The system includes A) Blood glucose meter, B) USB cable and C) DiaLife Mini setup tool. A. Blood glucose meter B. USB cable (DE03) C. DiaLife Mini A. Blood glucose meter : Please refer to the meter user manual. It supports meter models includes DA01, DA170 (DA210), DA160, DA161, DA140, DA051, and DA125. B. USB cable: The cable (DE03) is designed for DELBio blood glucose meters and can’t use to another brand. The type is 3.5 mm ear jack to USB cable C. DiaLife Mini system: The system is designed for downloading measurement data from blood glucose meter. When you start the DiaLife Mini, the main program window will show as below. Display the connection status. Display connection message. REV 04 07/16/2015 A9-5 of 23 II. Software installation Operation System: Desk-top or notebook computer installed with Microsoft Windows Vista, Windows2000, and WindowsXP or Windows7 operating systems. Hardware requirements: PC or NB with Intel (or Compatible) Pentium II 300 MHz processor or higher 32 Megabytes greater of available RAM 32 MB of free hard disk space minimum 800 x 600 or higher resolution monitor Blood glucose USB to Stereo 2.5 mm Cable (BG cable) Blood glucose meter There are two steps to setup the system: A. Install cable driver. B. Install DiaLife Mini. Manual install cable driver: If you want to just install cable driver, follow this part of instruction. When you download the DiaLife Mini setup file (.zip), decompress the file (unzip) first. The folder will include folder called drivers and DiaLifeMini_setup.exe. If you want to install the driver manually, go into the folder <drivers>. Otherwise just use DiaLifeMini setup program to install both cable driver and DiaLifeMini automatically. Please refer to “Install cable driver and DiaLife Mini by setup program”. And the folder includes CP210x_VP_Windows folder and CP210x_VCP_Win2K.exe file. REV 04 07/16/2015 A9-6 of 23 There are two cable drivers to support Microsoft Windows Operation System. Driver a. CP210x_VCP_Windows (6.6.1) Driver b. CP210x_VCP_Win2K.exe (6.3a) The Driver a can support the windows OS (Windows XP, Vista, Win7 and Win8) except Win2K. Select the driver depends on the destination Windows OS. If you use driver a, the folder includes two version for x64 is 64 bit OS and x86 is for general 32 bit OS version. Install cable driver and DiaLife Mini by setup program: A. Install DiaLife Mini Setup and it will check the driver version in your system if not found 6.5 for WindowsXP, Vista or Win7; or 6.3a for Windows 2000. The setup process will ask if you want to install the driver. REV 04 07/16/2015 A9-7 of 23 If you click <Yes> to install the newest driver, the driver install process will show. Or the old driver found, It will show as below. Click the next button. REV 04 07/16/2015 A9-8 of 23 Click the <Next> button. Click <I accept the terms of the license agreement>. REV 04 07/16/2015 A9-9 of 23 Click <Next> to use the default folder. Click <Install> to start install drivers. REV 04 07/16/2015 A9-10 of 23 After installation, click <finish>. REV 04 07/16/2015 A9-11 of 23 Install bridge driver. Just click <Install> button. After show the window as below, the install is finished. REV 04 07/16/2015 A9-12 of 23 B. Install blood glucose management software: 1. Click ‘DiaLifeMini_setup.exe’to install DiaLife Mini. 2. Start to install process and follow the instructions. 3. Read the license and click <I accept the agreement> then click next button. REV 04 07/16/2015 A9-13 of 23 4. Select the destination location or just click next button. 5. Select menu folder. Just click next button. REV 04 07/16/2015 A9-14 of 23 6. Select if create shortcut on desktop and just click the checkbox. 7. Click install button to start installation process. REV 04 07/16/2015 A9-15 of 23 8. Installing and copy files. 9. Install completely. After installing DiaLife Mini, the application will be found the application in menu. Desktop icon: REV 04 07/16/2015 A9-16 of 23 III. Start to use Before you use <DiaLife Mini>, please confirm the cable is plug-in meter and USB side well. After plug-in cable, the meter will turn on and show “PC”. Warning: The cable one side is ear jack and has four pins. The cable should be plug-in the meter connector as deep as possible and should not appear metal part after plug-in the meter connector. Otherwise the cable connector may short to in-correct pins, then transmission will fail. Warning: The cable can only be used with meter. Don’t use with other device. REV 04 07/16/2015 A9-17 of 23 1. Click the application of shortcut on desktop or in the program of menu. 2. Then the main windows will show in the middle of window. 3. Then software will try to connect meter and start to download data. REV 04 07/16/2015 A9-18 of 23 4. The software will find the total number and start to transfer data one by one. This may take several minutes depending on how many of your measurement data stored in your meter. The process information will show as Index [Current index] / [Total number]. And the software will start to export download data to csv file. REV 04 07/16/2015 A9-19 of 23 And ask user where to save the file. After saving the file, the file will automatically be opened by software if the system has installed Microsoft Office 2000 or later version. If you do not install Microsoft Office Excel, just use other text view such as notepad to open it. The content file will display the five columns: DATE, TIME, VALUE (mg/dL) ,VALUE (mmol/L)and MEMO. And the MEMO column will has “AC” or “PC” based on meter setting the flag before measurement. AC means “Before the meal”. PC means “After the meal”. REV 04 07/16/2015 A9-20 of 23 5. After exporting CSV file, the software will show “download finish”. Note: The data stored in meter won’t be cleared after download process. Or If meter have no data stored in memory, the message will show no “test results”. REV 04 07/16/2015 A9-21 of 23 IV. Trouble Shooting The system has been designed to work accurately under normal conditions. On rare occasions, the meter will display an error as below. When you are presented with an error, check for common problems within this chapter. Problem Possible Cause How To Fix It Connection fail Not plug in the cable at USB side Plug in the cable to PC USB port. Not found cable due to not install cable driver well. Reinstall cable driver again or re-install DiaLife Mini Not plug the cable at meter side well. Make sure the cable is plugged in the meter side well. Remove the cable when transmitting data Don’t remove the cable of meter side or USB side when transmitting data. DiaLife Mini waits to long for meter’s response. Try again if it still occurs the error; the cable may be broken, please contact to the DELBio. Time out Do download process when Don’t test strip when test mode. (Plug in strip) executing DaiLife Mini. Try again. REV 04 07/16/2015 A9-22 of 23 Manufacturer: DELBio Inc. 3F, No. 252, Shangying Road Guishan Industrial Zone Taoyuan County 33341, Taiwan, R.O.C. If you have any questions regarding this product, please contact: 1-855-9DELBIO or 1-855-933-5246, 9 AM to 5 PM, M-F EST. The users should contact their healthcare professionals at other times. www.delbio.com.tw REV 04 07/16/2015 A9-23 of 23