General Installation Instructions LED • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions and other hazards, please read all warnings and instructions included with and on the luminaire box and all luminaire labels. • Before installing, servicing or performing routine maintenance upon this equipment, follow these general precautions. • Installation and service of luminaires should be performed by a qualified licensed electrician. • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular luminaire maintenance programs are recommended. • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, nonabrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/ lens and clean in above manner, replacing damaged gaskets as necessary. • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced. • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov. • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc., a parent company of Peerless Lighting. WARNING RISK OF ELECTRIC SHOCK 4Disconnect or turn off power before installation or servicing. 4Verify that supply voltage is correct by comparing it with the luminaire label information. 4Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements. 4All wiring connections should be capped with UL approved recognized wire connectors. 4To prevent luminaire row from over-­current: By adding the input current of each luminaire section marked on the luminaire, the total current per power feed must not exceed the maximum line wire amperage marked on the luminaire and the power feed cord/wire amperage rating whichever the least. WARNING RISK OF BURN 4Allow lamp/luminaire to cool before handling. Do not touch enclosure or light source. 4Do not exceed maximum wattage marked on luminaire label. 4Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling. Part Number: PIN004102 Description: “INSTR, IMPORTANT SAFETY LED” Revision: C Effective Date: 07/2012 ECO3665 page 1 of 2 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com © 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx General Installation Instructions LED A General Installation Instructions LED CAUTION RISK OF INJURY CAUTION RISK OF FIRE 4Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance. 4Avoid direct eye exposure to the light source while it is on. 4Keep combustible and other materials that can burn away from lamp/lens. 4Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying. CAUTION RISK OF PRODUCT DAMAGE 4Never connect components under load. 4Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation. 4Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED luminaires must be powered directly off a switched circuit. 4Unless individual product specifications deem otherwise: Do not restrict luminaire ventilation. Allow for some volume of airspace around luminaire. Avoid covering LED luminaires with insulation, foam or other material that will prevent convection or conduction cooling. 4Unless individual product specifications deem otherwise: Do not exceed luminaire’s maximum ambient temperature. 4Only use luminaire in its intended location. 4LED products are polarity sensitive. Ensure proper polarity before installation. 4Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit. 4Do not touch individual electrical components as this can cause ESD, shorten lamp life or alter performance. 4Some components inside the luminaire may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact a Peerless Lighting representative for assistance. 4Always read the fixtures complete installation instructions prior to installation for any additional luminaire specific warnings. SAVE THESE INSTALLATION INSTRUCTIONS Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements. Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit PeerlessLighting.com. Peerless Lighting, an Acuity Brands Company, assumes no responsibility for claims arising out of improper or careless installation or handling of its products. Part Number: PIN004102 Description: “INSTR, IMPORTANT SAFETY LED” Revision: C Effective Date: 07/2012 ECO3665 page 2 of 2 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com © 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx General Installation Instructions LED B General Installation Instructions WARNING To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions, falling parts and other hazards: • Service of the equipment must be performed by qualified service personnel. • Installation and maintenance must be performed by a person familiar with the construction and operation of this product and any hazards involved. All applicable codes and ordinances must be followed. • Read this document before installing, servicing or maintaining this equipment or installing a lamp. These instructions do not cover all installation, service and maintenance situations. If your situation is not covered, or, if you do not understand these instructions or additional information is required, contact Peerless Lighting or your local Peerless Lighting distributor. • Read and follow all warnings and instructions provided by the lamp manufacturer. WARNING Before installing, servicing or maintaining this equipment, follow these general precautions. To reduce the risk of electrocution: • Make sure the equipment is properly grounded. • Always de-energize the circuit and/or equipment before connecting to, disconnecting from or servicing the equipment. To prevent luminaire row from over-current: • By adding the input current of each luminaire section marked on the luminaire, the total current per power feed must not exceed the maximum line wire amperage marked on the luminaire and the power feed cord/wire amperage rating whichever is the least. To reduce the risk of fire: • Keep material away that can burn from hot lamp. • Make sure lamps are correctly installed. • Use supply conductors with a minimum installation temperature rating as specified on equipment. To reduce the risk of personal injury from cuts, abrasions or falling parts: • Wear gloves to prevent cuts or abrasions from sharp edges when removing from carton, handling and maintaining this equipment. • Do not use abrasive materials, glass cleaners or other solvents on reflector or lens. These substances may damage equipment and cause parts to eventually break and fall. • Do not install a damaged fixture. CAUTION Observe lamp manufacturer’s recommendations and restrictions on lamp operation including but not limited to ballast type, burning position, replacement and cycling. Use only lamps that comply with applicable ANSI standards. NOTICE: If lamp is marked it contains mercury. Follow disposal laws. See www.lamprecycle.org Peerless Lighting, a division of Acuity Brands Lighting, Inc., assumes no responsibility for claims arising out of improper or careless installation or handling of this product. SAVE THESE INSTALLATION INSTRUCTIONS Part Number: PIN004100 Revision: E Effective Date: 07/2012 ECO3665 Staple Wall — LED and Fluorescent INSTALLATION INSTRUCTIONS PIN005901 REV. C 03/14 ECO3722 SPW9L/SPW9/SPW4 These installation instructions are used for installing the following luminaires and kits: Luminaires Support Location Mounting Kit SPW9L Normal Power Feed SPWFK SPW9 Non-Power Feed SPWSK SPW4 Luminaire End Cap Kit Dust Cover SPW9L SPW9EP or SPW9FEP SPW9LDU SPW9 SPW9EP or SPW9FEP SPW9DU SPW4 SPW4EP or SPW4FEP SPW4DU WARNING: Please read the “important safety instructions” prior to installation of this product. The mounting instructions can be found inside the mounting kits or downloaded from PeerlessLighting.com. A) Identification of SPW9L, SPW9 and SPW4 Luminaires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1 B) WALL-Mounted Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2-3 C) OPTIONAL Dust Cover (DU) Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3 A) Identification of SPW9L, SPW9 and SPW4 Luminaires SPW9L & SPW9 SPW4 Rounded (EP) ROUND End CapEND C AP WIRE WAY & MOUNTING CHANNEL POWER “PIGTAIL” WIRE CONNECTORS Squared (FEP) End Cap DIMENSIONS OF STANDARD SECTION 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com © 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Llimited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx Staple Wall — LED and Fluorescent installation instructions 1 Staple Wall – LED and Fluorescent PIN005901 REV. C 03/14 ECO3722 SPW9L/SPW9/SPW4 B) Wall-Mounted Installation 1 Using a laser or snap line, mark wall for center line. Using support spacing diagram determine locations of power feed and supports. Cut wall material and install 2”x4” J-box (by others) at feed location. Pull building wires as shown. 4 For individual luminaire (IND option). Raise the luminaire into position. Connect to building power using appropriate wire nuts (by others). Level and secure the luminaire to wall mounting brackets. Install wireway covers to complete the installation. Note: For modular luminaires, skip to Steps 5-10. 7 To join luminaires together, raise the connecting luminaire into position. Plug in the wire connectors. 2 Sandwich J-box cover plate between J-box and bracket as shown. Install mounting bracket to wall using (2) 1/4-20 bolts (by others). 5 Connect power feed wire harness as shown. Insert connection back into luminaire. Fold or break the aligner tab at joiner, install and secure end-cap. Raise the luminaire into position. Connect to building power using appropriate wire nuts (by others). Secure the luminaire to wall mounting brackets. 8 Connect the luminaire at the joiner location and secure to wall. Repeat Steps 6-8 until last section is hung. For modular fluorescent luminaires (left). Bolt luminaires together with (2) ¼-20 screws using a Philips screwdriver. For modular LED luminaires (right). Bolt luminaires together with (2) ¼-20 socket head screws using a 3/16 socket allen wrench. 3 Install non-power feed wall brackets to wall along laser/snap line using (2) 1/4-20 bolts per bracket. Use (2) wall brackets for 4’ and 8’ luminaire sections, (3) wall brackets for 12’ luminaire sections. 6 At non-power feed location for next luminaire in run, gently pull female wire harness from cavity (or cap-off) as shown. Disconnect and discard power feed (pigtail). 9 For the last luminaire, fold or break the aligner tab at joiner, install and secure endcap. Raise the luminaire into position. Plug in the wire connectors. Connect the luminaire at the joiner location and secure to wall as in Steps 7 and 8. 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com © 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx Staple Wall – LED and Fluorescent 2 Staple Suspended – LED and Fluorescent PIN005900 REV. D 03/14 ECO3722 SPM9L/SPM9/SPM4 10 Level the whole row at each hanger location as necessary. Tighten screws on all hangers. Install wireway covers on both ends to complete the installation. C) OPTIONAL Dust Cover (DU) Installation 1 For SPW9L (LED), simply remove the dust cover for cleaning during maintenance and then restore the part by overlaying it atop the luminaire as shown. 2 For SPW9 AND SPW4 (Fluorescent), simply remove the dust cover to re-lamp during maintenance and then replace the dust cover centering it over the lamp(s) as shown. 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: techsupport@peerlesslighting.com • PeerlessLighting.com © 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx Staple Suspended – LED and Fluorescent 2