P R PORDOUDCUT C G T UGI U D IED E Lighting Lighting Control Control andand Integrated Integrated Home Home Systems Systems Contents Occupancy Sensors Introduction Wall Switch Occupancy Sensors Ceiling Mounted Occupancy Sensors Wall Mounted Occupancy Sensors Power Pack & Auxiliary Relays High Bay HID Technical Section 1-24 1 3 11 15 18 19 20 C-BusTM Lighting Control Introduction Keypads Touch Screens System Units Input Units Sensors Output Units C-Bus Area Lighting Panels Introduction C-Bus Enclosures C-Bus Technical Section Wiser Home Control Introduction Wiser Home Controller Technical Section 25-59 25 27 33 36 43 46 52 61-83 62 63 70 85-88 86 87 88 C-Bus Multi-room Audio, Remote Controls and IR Accessories Introduction Matrix Switcher Multi-room Amplifiers Distribution Unit Speakers Universal Remote 4 & 8 Button Remotes IR Accessories Technical Section C-Bus HVAC Controls Introduction Basic and Programmable Thermostats Technical Section C-Bus RF Wireless Controls 89-100 90 91 92 93 94 95 96 97 98 Introduction 600W Dimmer 1000W Dimmer Switch and Scene Controllers Plug Adaptor Wireless RF Remote Wireless Gateway Technical Section 105-114 106 107 108 109 110 111 112 113 C-Bus Software 115-118 101-104 102 103 104 Design Guide 119-134 One Line Diagrams 135-136 Occupancy Sensors 1 Introduction to Occupancy Sensors Occupancy sensors help building owners achieve energy savings and energy code compliance with sensors that are easy to select, install and commission. Employing passive infrared (PIR), ultrasonic and dual technology to accurately detect occupancy and control lighting loads, occupancy sensors automatically shut-off lighting in unoccupied areas – eliminating waste, reducing energy costs and meeting code requirements. Schneider Electric innovations help building owners not only comply with energy codes, but they also maximize energy savings. t"EBQUJWF5FDIOPMPHZ1BUFOUQFOEJOH technology employs advanced algorithms to achieve convenient energy savings and reduced lamp and ballast maintenance. t *OUFHSBMMJHIUMFWFMTFOTPSTNBYJNJ[F energy savings in day-lit areas by holding off artificial lighting when adequate natural light is available. t 8BMLUISPVHINPEFEFUFDUTCSJFGQFSJPET of occupancy in private offices, allowing the sensor to shut-off lighting with less time delay. t -BNQTBWFSNPEFBMUFSOBUFTUIF"BOE B-loads in rooms using 50/50 bi-level lighting control to maximize lamp life and reduce maintenance. t *TPMBUFESFMBZTNBZCFVTFEUPDPNNVOJDBUF with other control systems, such as building automation and energy management systems that control other building systems, MJLF)7"$BOEMJHIUJOHUPGVSUIFSNBYJNJ[F energy savings. 4DIOFJEFS&MFDUSJDNBLFTMJHIUJOHDPOUSPM easy with a full line of versatile occupancy sensors. For most applications, the sensors may be installed right out of the box with no BEKVTUNFOU8IFOOFFEFEBEKVTUNFOUTBSF simple to understand and easy to access, NBLJOHDPNNJTTJPOJOHBCSFF[F Schneider Electric occupancy sensors were EFTJHOFEUPJOUFSGBDFXJUI$#VT5. lighting control systems, using normally open and OPSNBMMZDMPTFEDPOUBDUT"TMJHIUJOHDPOUSPM needs change and more sophisticated lighting control is desired, Schnieder Electric occupancy sensors interface with other systems to maximize energy savings and enhance occupant satisfaction. 2 OCCUPANCY SENSORS + WALL SWITCH OCCUPANCY SENSORS Wall Switch Occupancy Sensor w/Auto-On, Auto-Off 4DIOFJEFS&MFDUSJD8BMM4XJUDI0DDVQBODZ4FOTPSTFNQMPZUIFMBUFTUQBTTJWFJOGSBSFE (PIR) technology to automatically control lighting in offices, private restrooms and FNQMPZFFCSFBLSPPNT &BDI4FOTPSFNQMPZTBTQFDJBM¡NVMUJTFHNFOUFEMFOTBOE1*3NPUJPOEFUFDUPS DJSDVJUUPEFUFDUNPUJPO5IJTVOJUXJMMBVUPNBUJDBMMZTXJUDIUIFMJHIUTPGGBGUFSBQSFTFU delay if no motion is detected. 4DIOFJEFS&MFDUSJD8BMM4XJUDI0DDVQBODZ4FOTPSýUTJOQMBDFPGFYJTUJOHXBMMTXJUDIFT connecting to existing active line and ground wiring similar to a typical wall switch. No neutral or minimum load is required. 5PBTTVSFMPOHSFMBZMJGF4DIOFJEFS&MFDUSJDIBTEFWFMPQFEBMPXFOFSHZTXJUDIDJSDVJU UPBTTVSFNBYJNVNDPOUBDUMJGF5IFTFTFOTPSTBSFDPNQBUJCMFXJUIFMFDUSPOJDBOE magnetic ballast loads, and require no minimum load. 8BMM4XJUDI Occupancy Sensor Technical Information Product Features *OQVU 0VUQVU PS7BD)[ 7BD 8NBYJODBOEFTDFOUMPBE 7"NBYCBMMBTUMPBE ¼ hp max. motor load 0QFSBUJOH5FNQFSBUVSF 7"NBYCBMMBTUMPBE ¡'¡$ )VNJEJUZ NBYSFMBUJWFIVNJEJUZOPODPOEFOTJOH 4UBOEBSE 6-BOED6--JTUFE'$$1BSU )PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 19 Catalog Number 3 7BD Description 4-4184"* 8BMM4XJUDI0DDVQBODZ4FOTPSJWPSZ 4-4184"8 8BMM4XJUDI0DDVQBODZ4FOTPSXIJUF t"WBJMBCMFJOXIJUFBOEJWPSZXJUI matching decorator wall plate cover t"VUP0O"VUP0GG t.BOVBMCZQBTT tPS7BDJOQVUOPOFVUSBM required) t/PQPXFSQBDLSFRVJSFE t/PNJOJNVNMPBE t¡ýFMEPGWJFX6QUP sq. ft.) t6TFSBEKVTUBCMFUJNFEFMBZGSPN TFDNJOVUFT t3FE-&%NPUJPOJOEJDBUPSCMJOLT to indicate motion detection t4VJUBCMFGPSVTFPOBMMFMFDUSPOJD and magnetic ballasts t'VSOJTIFEXJUI YJODI external wires (pig tails) t6-BOED6--JTUFE t'JWFZFBSXBSSBOUZ OCCUPANCY SENSORS + WALL SWITCH OCCUPANCY SENSORS Wall Switch Occupancy Sensor w/Manual On 4DIOFJEFS&MFDUSJD8BMM4XJUDI0DDVQBODZ4FOTPSXJUI.BOVBM0OFNQMPZTUIFMBUFTU passive infrared (PIR) technology to automatically control lighting in offices, employee CSFBLSPPNTBOEVUJMJUZSPPNT 'PSNBYJNVNFOFSHZTBWJOHTUIF4DIOFJEFS&MFDUSJD8BMM4XJUDI0DDVQBODZ4FOTPS XJUI.BOVBM0OSFRVJSFTUIFVTFSUPTXJUDIPOMJHIUJOHNBOVBMMZCZQSFTTJOHUIFCVUUPO POUIFGSPOU&NQMPZJOHBTQFDJBM¡NVMUJTFHNFOUFEMFOTBOE1*3NPUJPOTFOTPSUIF TFOTPSSFMJBCMZEFUFDUTPDDVQBODZUPLFFQMJHIUTPOXIJMFUIFSPPNJTPDDVQJFE5IJTVOJU will automatically switch the lights off after a pre-set delay if no motion is detected. 4DIOFJEFS&MFDUSJD8BMM4XJUDI0DDVQBODZ4FOTPSJTFBTZUPJOTUBMM$POOFDUJOHUP FYJTUJOHBDUJWFMJOFBOEHSPVOEXJSJOHTJNJMBSUPBUZQJDBMXBMMTXJUDIUIF8BMM4XJUDI Occupancy Sensor is the simplest way to achieve energy-saving lighting control with minimal installation time. 5PBTTVSFMPOHSFMBZMJGF4DIOFJEFS&MFDUSJDIBTEFWFMPQFEBMPXFOFSHZTXJUDIDJSDVJU UPBTTVSFNBYJNVNDPOUBDUMJGF5IFTFTFOTPSTBSFDPNQBUJCMFXJUIFMFDUSPOJDBOE magnetic ballast loads, and require no minimum load. Technical Information Product Features *OQVU 0VUQVU PS7BD)[ 7BD 8NBYJODBOEFTDFOUMPBE 7"NBYCBMMBTUMPBE ¼ hp max. motor load 0QFSBUJOH5FNQFSBUVSF 7BD 7"NBYCBMMBTUMPBE ¡'¡$ )VNJEJUZ NBYSFMBUJWFIVNJEJUZOPODPOEFOTJOH 4UBOEBSE 6-BOED6--JTUFE'$$1BSU )PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 19 Catalog Number 8BMM4XJUDI 0DDVQBODZ4FOTPS8.BOVBM0O t"WBJMBCMFJOXIJUFBOEJWPSZXJUI matching decorator wall plate cover t"VUP0O"VUP0GG t.BOVBMCZQBTT tPS7BDJOQVUOPOFVUSBM required) t/PQPXFSQBDLSFRVJSFE t/PNJOJNVNMPBE t¡ýFMEPGWJFX6QUP sq.ft.) t6TFSBEKVTUBCMFUJNFEFMBZGSPN TFDNJOVUFT t3FE-&%NPUJPOJOEJDBUPSCMJOLT to indicate motion detection t4VJUBCMFGPSVTFPOBMMFMFDUSPOJD and magnetic ballasts t'VSOJTIFEXJUI YJODI external wires (pig tails) t6-BOED6--JTUFE t'JWFZFBSXBSSBOUZ Description 4-4184.8 8BMM4XJUDI0DDVQBODZ4FOTPS8JUI.BOVBM0OXIJUF 4-4184.* 8BMM4XJUDI0DDVQBODZ4FOTPS8JUI.BOVBM0OJWPSZ 4 OCCUPANCY SENSORS + WALL SWITCH OCCUPANCY SENSORS Commercial Grade Occupancy Sensor PIR Single Circuit Wall Switch 4DIOFJEFS&MFDUSJD4JOHMF$JSDVJU1*38BMM4XJUDI0DDVQBODZ4FOTPSXJUI-JHIU-FWFMGFBUVSFT passive infrared (PIR) technology to conveniently control lighting in offices, private bathrooms, VUJMJUZSPPNTBOEFNQMPZFFCSFBLSPPNT-PXQSPýMFTFOTPSBWBJMBCMFJOXIJUFJWPSZHSBZMJHIU BMNPOEBOECMBDLXJUIDPMPSNBUDIFETFHNFOUFEMFOTUPNFFUBOZEÏDPSOFFE Adaptive Technology: New patent pending technology employs advanced algorithms to achieve convenient energy savings and reduced lamp and ballast maintenance Walk-Through Mode: 5PNBYJNJ[FFOFSHZTBWJOHTUIFTFOTPSEFUFDUTXIFOBSFBTBSFCSJFþZ PDDVQJFEBTBSFTVMUPGBQFSTPOXBMLJOHUISPVHIBOEUVSOTPGGMJHIUJOHCBTFEPOBTIPSUFSUJNFEFMBZ Light Level Sensor Mode: Each sensor includes an adjustable light level sensor to hold off artificial MJHIUJOHXIFOBEFRVBUFOBUVSBMMJHIUJTQSFTFOU8IFOOBUVSBMMJHIUMFWFMTESPQCFMPXUIFUISFTIPMEUIF sensor will turn on artificial lighting in occupied spaces. 5IFTFOTPSEPFTOPUSFRVJSFBOFVUSBMDPOOFDUJPOPSNJOJNVNMPBENBLJOHJUHSFBUGPSSFUSPýUT Easily replaces an existing wall switch using existing wiring – no wiring modifications required. .BUDIJOHXBMMTXJUDIDPWFSQMBUFNBLFTSFUSPýUTDMFBOBOETJNQMF 4JOHMF$JSDVJU8BMM4XJUDI Occupancy Sensor Technical Information Product Features *OQVU 0VUQVU 7BD 8NBYUVOHTUFO incandescent load IQNBYNPUPSMPBE7BD 7"NBYCBMMBTUMPBE 7BD)[ 0QFSBUJOH5FNQFSBUVSF )VNJEJUZ 5JNF%FMBZ"EKVTUNFOU /PSNBM 8BML5ISPVHI.PEF 5FTU.PEF 7"NBYCBMMBTUMPBE 3)/PODPOEFOTJOH NJOVUFT NJOVUFTJGOPBDUJWJUZJTEFUFDUFEBGUFSTFDPOET TFDPOET '$ %FUFDUJPO ¡QBTTJWFJOGSBSFE1*3 "VEJCMF"MFSU 4FMFDUBCMF 4FSWJDF4XJUDI 0''"VUP0/ .BOVBM0QFSBUJPO 1VTICVUUPO0/0'' -FOT *NQBDU3FTJTUBOU 3FMBZ4XJUDIJOH ¡V4 4UBOEBSET 6-BOED6--JTUFE'$$1BSU )PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 19 5 7BD ¡'¡$ -JHIU-FWFMBEKVTUNFOU Catalog Number Description 4-418468 8IJUF 4-41846* *WPSZ 4-41846( (SBZ 4-41846- -JHIU"MNPOE 4-41846# #MBDL t"WBJMBCMFJOXIJUFJWPSZHSBZMJHIU BMNPOEBOECMBDLXJUINBUDIJOH wall switch cover plate t$PMPSNBUDIJOHNVMUJTFHNFOUFE lens t4FMFDUBCMFBVUPPOBOENBOVBM on modes t7BD)[JOQVU t¡ýFMEPGWJFX tTRGUNBKPSNPUJPOBOE TRGUNJOPSNPUJPO coverage area t-JHIUMFWFMTFOTPS t8BMLUISPVHINPEF t"EKVTUBCMFMJHIUMFWFMUJNFEFMBZ and sensitivity t3FE-&%NPUJPOJOEJDBUPS t'PSVTFXJUIFMFDUSPOJDBOE magnetic ballasts t/POFVUSBMDPOOFDUJPONJOJNVN MPBEPSQPXFSQBDLSFRVJSFE t6-BOED6--JTUFEGPS6OJUFE 4UBUFTBOE$BOBEB t5FTUNPEFTFDPOEUJNFEFMBZ t'JWFZFBSXBSSBOUZ + OCCUPANCY SENSORS WALL SWITCH OCCUPANCY SENSORS Commercial Grade Occupancy Sensor PIR Dual Circuit Wall Switch %VBM$JSDVJU8BMM4XJUDI0DDVQBODZ4FOTPSTJOEFQFOEFOUMZDPOUSPMUXPMJHIUJOHDJSDVJUTXJUICJMFWFM TXJUDIJOHUPSFEVDFMJHIUJOHCZXIJDINBZCFSFRVJSFECZFOFSHZDPEFT5IFEVBMDJSDVJUXBMM TXJUDIPDDVQBODZTFOTPSFNQMPZTQBTTJWFJOGSBSFE1*3 UFDIOPMPHZBOEBEFHSFFTFHNFOUFEMFOT UPBDIJFWFNJOPSNPUJPODPWFSBHFVQUPTRVBSFGFFUTRNFUFST UPSFMJBCMZDPOUSPMMJHIUJOHJO PGýDFTDPOGFSFODFSPPNTBOEFNQMPZFFCSFBLSPPNT Adaptive Technology: New patent pending technology employs advanced algorithms to achieve convenient energy savings and reduced lamp and ballast maintenance. Lamp Saver Mode:8IFOUIFMBNQTBWFSGFBUVSFJTFOBCMFEUIFTFOTPSBVUPNBUJDBMMZBMUFSOBUFTXIJDI DJSDVJUSFTQPOETUPNPUJPO5IFSFTVMUJTNPSFQSFEJDUBCMFMBNQMJGFBOESFEVDFENBJOUFOBODF Walk-Through Mode:5PNBYJNJ[FFOFSHZTBWJOHTUIFTFOTPSEFUFDUTXIFOBSFBTBSFCSJFþZ PDDVQJFEBTBSFTVMUPGBQFSTPOXBMLJOHUISPVHIBOEUVSOTPGGMJHIUJOHCBTFEPOBTIPSUFSUJNFEFMBZ Light Level Sensor Mode: Each sensor includes an adjustable light level sensor to hold off artificial MJHIUJOHXIFOBEFRVBUFOBUVSBMMJHIUJTQSFTFOU8IFOOBUVSBMMJHIUMFWFMTESPQCFMPXUIFUISFTIPMEUIF sensor will turn on artificial lighting in occupied spaces. 5IFTFOTPSFBTJMZSFQMBDFTUXPXBMMTXJUDIFTVTJOHFYJTUJOHXJSJOHXJUIOPXJSJOHNPEJýDBUJPOTSFRVJSFE Optional 2-gang wall switch cover plates available in matching colors. %VBM$JSDVJU8BMM4XJUDI Occupancy Sensor Technical Information Product Features *OQVU 0VUQVU 7BD 8NBYUVOHTUFO incandescent load IQNBYNPUPSMPBE7BD 7"NBYCBMMBTUMPBE 7BD)[ 0QFSBUJOH5FNQFSBUVSF )VNJEJUZ 5JNF%FMBZ"EKVTUNFOU /PSNBM 8BML5ISPVHI.PEF 5FTU.PEF t"WBJMBCMFJOXIJUFJWPSZHSBZMJHIU BMNPOEBOECMBDLXJUINBUDIJOH wall switch cover plate t$PMPSNBUDIJOHNVMUJTFHNFOUFE lens t4FMFDUBCMFBVUPPOBOENBOVBM on modes t7BD)[JOQVU t¡ýFMEPGWJFX tTRGUNBKPSNPUJPOBOE TRGUNJOPSNPUJPODPWFSBHF area t-JHIUMFWFMTFOTPS t8BMLUISPVHINPEF t"EKVTUBCMFMJHIUMFWFMUJNFEFMBZ and sensitivity t3FE-&%NPUJPOJOEJDBUPS t'PSVTFXJUIFMFDUSPOJDBOE magnetic ballasts t/POFVUSBMDPOOFDUJPONJOJNVN MPBEPSQPXFSQBDLSFRVJSFE t6-BOED6--JTUFEGPS6OJUFE 4UBUFTBOE$BOBEB t5FTUNPEFTFDPOEUJNFEFMBZ t'JWFZFBSXBSSBOUZ 7BD 7"NBYCBMMBTUMPBE ¡'¡$ 3)/PODPOEFOTJOH NJOVUFT NJOVUFTJGOPBDUJWJUZJTEFUFDUFEBGUFSTFDPOET TFDPOET -JHIU-FWFMBEKVTUNFOU '$ %FUFDUJPO ¡QBTTJWFJOGSBSFE1*3 "VEJCMF"MFSU 4FMFDUBCMF 4FSWJDF4XJUDI 0''"VUP0/ .BOVBM0QFSBUJPO 1VTICVUUPO0/0'' -FOT *NQBDU3FTJTUBOU 3FMBZ4XJUDIJOH ¡V4 4UBOEBSET 6-BOED6--JTUFE'$$1BSU )PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 19 Catalog Number Description Blank Catalog Number 4-418%68 8IJUF 4-4181%#8 4-4181%58 4-418%6* *WPSZ 4-4181%#* 4-4181%5* *WPSZ 4-418%6( (SBZ 4-4181%#( 4-4181%5( (SBZ 4-418%6- -JHIU"MNPOE 4-418%6# #MBDL 4-4181%#- 4-4181%## Toggle Catalog Number 8IJUF 4-4181%5- 4-4181%5# Description -JHIU"MNPOE #MBDL 6 OCCUPANCY SENSORS + WALL SWITCH OCCUPANCY SENSORS Commercial Grade Occupancy Sensor Ultrasonic Single Circuit Wall Switch 4DIOFJEFS&MFDUSJD4JOHMF$JSDVJU1*38BMM4XJUDI0DDVQBODZ4FOTPSXJUI-JHIU-FWFMGFBUVSFT passive infrared (PIR) technology to conveniently control lighting in offices, private bathrooms, VUJMJUZSPPNTBOEFNQMPZFFCSFBLSPPNT-PXQSPýMFTFOTPSBWBJMBCMFJOXIJUFJWPSZHSBZMJHIU BMNPOEBOECMBDLXJUIDPMPSNBUDIFETFHNFOUFEMFOTUPNFFUBOZEÏDPSOFFE Adaptive Technology: New patent pending technology employs advanced algorithms to achieve convenient energy savings and reduced lamp and ballast maintenance Walk-Through Mode: 5PNBYJNJ[FFOFSHZTBWJOHTBOESFEVDFXBTUFUIFTFOTPSEFUFDUTXIFO BSFBTBSFCSJFþZPDDVQJFEBTBSFTVMUPGBOPDDVQBOUXBMLJOHUISPVHIBOEUVSOTPGGMJHIUJOH based on a shorter time delay. Light Level Sensor Mode: Each sensor includes an adjustable light level sensor to hold off BSUJýDJBMMJHIUJOHXIFOBEFRVBUFOBUVSBMMJHIUJTQSFTFOU8IFOOBUVSBMMJHIUMFWFMTESPQCFMPXUIF threshold, the sensor will turn on artificial lighting in occupied spaces. 5IFTFOTPSEPFTOPUSFRVJSFBOFVUSBMDPOOFDUJPOPSNJOJNVNMPBENBLJOHJUHSFBUGPSSFUSPýUT Easily replaces an existing wall switch using existing wiring – no wiring modifications required. .BUDIJOHXBMMTXJUDIDPWFSQMBUFNBLFTSFUSPýUTDMFBOBOETJNQMF 4JOHMF$JSDVJU8BMM4XJUDI Occupancy Sensor Technical Information Product Features Input 0VUQVU 7BD)[ 7BD 8NBYUVOHTUFO incandescent load IQNBYNPUPSMPBE7BD 7"NBYCBMMBTUMPBE 0QFSBUJOH5FNQFSBUVSF )VNJEJUZ 3)/PODPOEFOTJOH NJOVUFT NJOVUFTJGOPBDUJWJUZJTEFUFDUFEBGUFSTFDPOET TFDPOET -JHIU-FWFMBEKVTUNFOU '$ ¡QBTTJWFJOGSBSFE1*3 "VEJCMF"MFSU 4FMFDUBCMF 4FSWJDF4XJUDI 0''"VUP0/ .BOVBM0QFSBUJPO 1VTICVUUPO0/0'' -FOT *NQBDU3FTJTUBOU 3FMBZ4XJUDIJOH ¡V4 4UBOEBSET 6-BOED6--JTUFE'$$1BSU )PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 19 Catalog Number 7 7"NBYCBMMBTUMPBE ¡'¡$ 5JNF%FMBZ"EKVTUNFOU /PSNBM 8BML5ISPVHI.PEF 5FTU.PEF %FUFDUJPO 7BD Description 4-46846* *WPSZ 4-468468 8IJUF 4-46846- -JHIU"MNPOE 4-46846( (SBZ 4-46846# #MBDL t"WBJMBCMFJOXIJUFJWPSZHSBZMJHIU BMNPOEBOECMBDLXJUINBUDIJOH wall switch cover plate t$PMPSNBUDIJOHNVMUJTFHNFOUFE lens t4FMFDUBCMFBVUPPOBOENBOVBM on modes t7BD)[JOQVU t¡ýFMEPGWJFX tTRGUNBKPSNPUJPOBOE TRGUNJOPSNPUJPODPWFSBHF area t-JHIUMFWFMTFOTPS t8BMLUISPVHINPEF t"EKVTUBCMFMJHIUMFWFMUJNFEFMBZ and sensitivity t3FE-&%NPUJPOJOEJDBUPS t'PSVTFXJUIFMFDUSPOJDBOE magnetic ballasts t/POFVUSBMDPOOFDUJPONJOJNVN MPBEPSQPXFSQBDLSFRVJSFE t6-BOED6--JTUFEGPS6OJUFE 4UBUFTBOE$BOBEB t5FTUNPEFTFDPOEUJNFEFMBZ t'JWFZFBSXBSSBOUZ OCCUPANCY SENSORS + WALL SWITCH OCCUPANCY SENSORS Commercial Grade Occupancy Sensor Ultrasonic Dual Circuit Wall Switch %VBM$JSDVJU8BMM4XJUDI0DDVQBODZ4FOTPSTJOEFQFOEFOUMZDPOUSPMUXPMJHIUJOHDJSDVJUTXJUI CJMFWFMTXJUDIJOHUPSFEVDFMJHIUJOHCZXIJDINBZCFSFRVJSFECZFOFSHZDPEFT5IF dual circuit wall switch occupancy sensor employs passive infrared (PIR) technology and a EFHSFFTFHNFOUFEMFOTUPBDIJFWFNJOPSNPUJPODPWFSBHFVQUPTRVBSFGFFU TRNFUFST UPSFMJBCMZDPOUSPMMJHIUJOHJOPGýDFTDPOGFSFODFSPPNTBOEFNQMPZFFCSFBL rooms. Adaptive Technology: New patent pending technology employs advanced algorithms to achieve convenient energy savings and reduced lamp and ballast maintenance. Lamp Saver Mode:8IFOUIFMBNQTBWFSGFBUVSFJTFOBCMFEUIFTFOTPSBVUPNBUJDBMMZ BMUFSOBUFTXIJDIDJSDVJUSFTQPOETUPNPUJPO5IFSFTVMUJTNPSFQSFEJDUBCMFMBNQMJGFBOE reduced maintenance. Walk-Through Mode:5PNBYJNJ[FFOFSHZTBWJOHTUIFTFOTPSEFUFDUTXIFOBSFBTBSF CSJFþZPDDVQJFEBTBSFTVMUPGBQFSTPOXBMLJOHUISPVHIBOEUVSOTPGGMJHIUJOHCBTFEPOB shorter time delay. Light Level Sensor Mode: Each sensor includes an adjustable light level sensor to hold off BSUJýDJBMMJHIUJOHXIFOBEFRVBUFOBUVSBMMJHIUJTQSFTFOU8IFOOBUVSBMMJHIUMFWFMTESPQCFMPX the threshold, the sensor will turn on artificial lighting in occupied spaces. %VBM$JSDVJU8BMM4XJUDI Occupancy Sensor 5IFTFOTPSFBTJMZSFQMBDFTUXPXBMMTXJUDIFTVTJOHFYJTUJOHXJSJOHXJUIOPXJSJOH modifications required. Optional 2-gang wall switch cover plates available in matching colors. Technical Information Input 7BD 8NBYUVOHTUFO incandescent load IQNBYNPUPSMPBE7BD 7"NBYCBMMBTUMPBE 0QFSBUJOH5FNQFSBUVSF )VNJEJUZ 7BD 7"NBYCBMMBTUMPBE ¡'¡$ 3)/PODPOEFOTJOH 5JNF%FMBZ"EKVTUNFOU /PSNBM 8BML5ISPVHI.PEF 5FTU.PEF NJOVUFT NJOVUFTJGOPBDUJWJUZJTEFUFDUFEBGUFSTFDPOET TFDPOET -JHIU-FWFMBEKVTUNFOU %FUFDUJPO t"WBJMBCMFJOXIJUFJWPSZHSBZMJHIU BMNPOEBOECMBDLXJUINBUDIJOH wall switch cover plate t$PMPSNBUDIJOHNVMUJTFHNFOUFE lens t4FMFDUBCMFBVUPPOBOENBOVBM on modes t7BD)[JOQVU t¡ýFMEPGWJFX tTRGUNBKPSNPUJPOBOE TRGUNJOPS motion coverage area t-JHIUMFWFMTFOTPS t8BMLUISPVHINPEF t"EKVTUBCMFMJHIUMFWFMUJNFEFMBZ and sensitivity t3FE-&%NPUJPOJOEJDBUPS t'PSVTFXJUIFMFDUSPOJDBOE magnetic ballasts t/POFVUSBMDPOOFDUJPONJOJNVN MPBEPSQPXFSQBDLSFRVJSFE t6-BOED6--JTUFEGPS6OJUFE 4UBUFTBOE$BOBEB t5FTUNPEFTFDPOEUJNFEFMBZ t'JWFZFBSXBSSBOUZ 7BD)[ 0VUQVU Product Features '$ ¡QBTTJWFJOGSBSFE1*3 "VEJCMF"MFSU 4FMFDUBCMF 4FSWJDF4XJUDI 0''"VUP0/ .BOVBM0QFSBUJPO 1VTICVUUPO0/0'' -FOT *NQBDU3FTJTUBOU 3FMBZ4XJUDIJOH ¡V4 4UBOEBSET 6-BOED6--JTUFE'$$1BSU )PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 19 Catalog Number Description 4-468%6* *WPSZ 4-4181%#8 4-4181%58 4-468%68 8IJUF 4-4181%#* 4-4181%5* *WPSZ 4-468%6- -JHIU"MNPOE 4-4181%#( 4-4181%5( (SBZ Blank Catalog Number Toggle Catalog Number Description 8IJUF 4-468%6( (SBZ 4-4181%#- 4-4181%5- -JHIU"MNPOE 4-468%6# #MBDL 4-4181%## 4-4181%5# #MBDL 8 OCCUPANCY SENSORS + WALL SWITCH OCCUPANCY SENSORS Commercial Grade Occupancy Sensor Dual Technology Single Circuit Wall Switch 4DIOFJEFS&MFDUSJD4JOHMF$JSDVJU1*38BMM4XJUDI0DDVQBODZ4FOTPSXJUI-JHIU-FWFMGFBUVSFT passive infrared (PIR) technology to conveniently control lighting in offices, private bathrooms, VUJMJUZSPPNTBOEFNQMPZFFCSFBLSPPNT-PXQSPýMFTFOTPSBWBJMBCMFJOXIJUFJWPSZHSBZMJHIU BMNPOEBOECMBDLXJUIDPMPSNBUDIFETFHNFOUFEMFOTUPNFFUBOZEÏDPSOFFE Adaptive Technology: New patent pending technology employs advanced algorithms to achieve convenient energy savings and reduced lamp and ballast maintenance Walk-Through Mode: 5PNBYJNJ[FFOFSHZTBWJOHTUIFTFOTPSEFUFDUTXIFOBSFBTBSFCSJFþZ PDDVQJFEBTBSFTVMUPGBQFSTPOXBMLJOHUISPVHIBOEUVSOTPGGMJHIUJOHCBTFEPOBTIPSUFSUJNF delay. Light Level Sensor Mode: Each sensor includes an adjustable light level sensor to hold off BSUJýDJBMMJHIUJOHXIFOBEFRVBUFOBUVSBMMJHIUJTQSFTFOU8IFOOBUVSBMMJHIUMFWFMTESPQCFMPXUIF threshold, the sensor will turn on artificial lighting in occupied spaces. 5IFTFOTPSEPFTOPUSFRVJSFBOFVUSBMDPOOFDUJPOPSNJOJNVNMPBENBLJOHJUHSFBUGPSSFUSPýUT Easily replaces an existing wall switch using existing wiring – no wiring modifications required. .BUDIJOHXBMMTXJUDIDPWFSQMBUFNBLFTSFUSPýUTDMFBOBOETJNQMF 4JOHMF$JSDVJU8BMM4XJUDI Occupancy Sensor Technical Information Product Features Input 0VUQVU 7BD)[ 7BD 8NBYUVOHTUFO incandescent load IQNBYNPUPSMPBE7BD 7"NBYCBMMBTUMPBE 7BD 7"NBYCBMMBTUMPBE 0QFSBUJOH5FNQFSBUVSF ¡'¡$ )VNJEJUZ 3)/PODPOEFOTJOH 5JNF%FMBZ"EKVTUNFOU /PSNBM 8BML5ISPVHI.PEF 5FTU.PEF NJOVUFT NJOVUFTJGOPBDUJWJUZJTEFUFDUFEBGUFSTFDPOET TFDPOET -JHIU-FWFMBEKVTUNFOU '$ %FUFDUJPO ¡QBTTJWFJOGSBSFE1*3 "VEJCMF"MFSU 4FMFDUBCMF 4FSWJDF4XJUDI 0''"VUP0/ .BOVBM0QFSBUJPO 1VTICVUUPO0/0'' -FOT *NQBDU3FTJTUBOU 3FMBZ4XJUDIJOH ¡V4 4UBOEBSET 6-BOED6--JTUFE'$$1BSU )PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 20 Catalog Number 9 Description 4-4%846* *WPSZ 4-4%8468 8IJUF 4-4%846- -JHIU"MNPOE 4-4%846( (SBZ 4-4%846# #MBDL t"WBJMBCMFJOXIJUFJWPSZHSBZMJHIU BMNPOEBOECMBDLXJUINBUDIJOH wall switch cover plate t$PMPSNBUDIJOHNVMUJTFHNFOUFE lens t4FMFDUBCMFBVUPPOBOENBOVBM on modes t7BD)[JOQVU t¡ýFMEPGWJFX tTRGUNBKPSNPUJPOBOE TRGUNJOPSNPUJPODPWFSBHF area t-JHIUMFWFMTFOTPS t8BMLUISPVHINPEF t"EKVTUBCMFMJHIUMFWFMUJNFEFMBZ and sensitivity t3FE-&%NPUJPOJOEJDBUPS t'PSVTFXJUIFMFDUSPOJDBOE magnetic ballasts t/POFVUSBMDPOOFDUJPONJOJNVN MPBEPSQPXFSQBDLSFRVJSFE t6-BOED6--JTUFEGPS6OJUFE 4UBUFTBOE$BOBEB t5FTUNPEFTFDPOEUJNFEFMBZ t'JWFZFBSXBSSBOUZ OCCUPANCY SENSORS + WALL SWITCH OCCUPANCY SENSORS Commercial Grade Occupancy Sensor Dual Technology Dual Circuit Wall Switch %VBM$JSDVJU8BMM4XJUDI0DDVQBODZ4FOTPSTJOEFQFOEFOUMZDPOUSPMUXPMJHIUJOHDJSDVJUTXJUICJMFWFM TXJUDIJOHUPSFEVDFMJHIUJOHCZXIJDINBZCFSFRVJSFECZFOFSHZDPEFT5IFEVBMDJSDVJUXBMMTXJUDI PDDVQBODZTFOTPSFNQMPZTQBTTJWFJOGSBSFE1*3 UFDIOPMPHZBOEBEFHSFFTFHNFOUFEMFOTUP BDIJFWFNJOPSNPUJPODPWFSBHFVQUPTRVBSFGFFUTRNFUFST UPSFMJBCMZDPOUSPMMJHIUJOHJO PGýDFTDPOGFSFODFSPPNTBOEFNQMPZFFCSFBLSPPNT Adaptive Technology: New patent pending technology employs advanced algorithms to achieve convenient energy savings and reduced lamp and ballast maintenance. Lamp Saver Mode: 8IFOUIFMBNQTBWFSGFBUVSFJTFOBCMFEUIFTFOTPSBVUPNBUJDBMMZBMUFSOBUFTXIJDI DJSDVJUSFTQPOETUPNPUJPO5IFSFTVMUJTNPSFQSFEJDUBCMFMBNQMJGFBOESFEVDFENBJOUFOBODF Walk-Through Mode:5PNBYJNJ[FFOFSHZTBWJOHTUIFTFOTPSEFUFDUTXIFOBSFBTBSFCSJFþZ PDDVQJFEBTBSFTVMUPGBQFSTPOXBMLJOHUISPVHIBOEUVSOTPGGMJHIUJOHCBTFEPOBTIPSUFSUJNFEFMBZ Light Level Sensor Mode: Each sensor includes an adjustable light level sensor to hold off artificial MJHIUJOHXIFOBEFRVBUFOBUVSBMMJHIUJTQSFTFOU8IFOOBUVSBMMJHIUMFWFMTESPQCFMPXUIFUISFTIPMEUIF sensor will turn on artificial lighting in occupied spaces. 5IFTFOTPSFBTJMZSFQMBDFTUXPXBMMTXJUDIFTVTJOHFYJTUJOHXJSJOHXJUIOPXJSJOHNPEJýDBUJPOTSFRVJSFE Optional 2-gang wall switch cover plates available in matching colors. Technical Information Product Features Input 0VUQVU t"WBJMBCMFJOXIJUFJWPSZHSBZMJHIU BMNPOEBOECMBDLXJUINBUDIJOH wall switch cover plate t$PMPSNBUDIJOHNVMUJTFHNFOUFE lens t4FMFDUBCMFBVUPPOBOENBOVBM on modes t7BD)[JOQVU t¡ýFMEPGWJFX tTRGUNBKPSNPUJPOBOE TRGUNJOPSNPUJPODPWFSBHF area t-JHIUMFWFMTFOTPS t8BMLUISPVHINPEF t"EKVTUBCMFMJHIUMFWFMUJNFEFMBZ and sensitivity t3FE-&%NPUJPOJOEJDBUPS t'PSVTFXJUIFMFDUSPOJDBOE magnetic ballasts t/POFVUSBMDPOOFDUJPONJOJNVN MPBEPSQPXFSQBDLSFRVJSFE t6-BOED6--JTUFEGPS6OJUFE 4UBUFTBOE$BOBEB t5FTUNPEFTFDPOEUJNFEFMBZ t'JWFZFBSXBSSBOUZ 7BD)[ 7BD 8NBYUVOHTUFO incandescent load IQNBYNPUPSMPBE7BD 7"NBYCBMMBTUMPBE 7BD 7"NBYCBMMBTUMPBE 0QFSBUJOH5FNQFSBUVSF ¡'¡$ )VNJEJUZ 3)/PODPOEFOTJOH 5JNF%FMBZ"EKVTUNFOU /PSNBM 8BML5ISPVHI.PEF 5FTU.PEF NJOVUFT NJOVUFTJGOPBDUJWJUZJTEFUFDUFEBGUFSTFDPOET TFDPOET -JHIU-FWFMBEKVTUNFOU '$ %FUFDUJPO ¡QBTTJWFJOGSBSFE1*3 "VEJCMF"MFSU 4FMFDUBCMF 4FSWJDF4XJUDI 0''"VUP0/ .BOVBM0QFSBUJPO 1VTICVUUPO0/0'' -FOT *NQBDU3FTJTUBOU 3FMBZ4XJUDIJOH ¡V4 4UBOEBSET 6-BOED6--JTUFE'$$1BSU )PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE %VBM$JSDVJU8BMM4XJUDI Occupancy Sensor *For Diagram see technical section page 20 Catalog Number Description 4-4%8%6* *WPSZ 4-4181%#8 4-4181%58 4-4%8%68 8IJUF 4-4181%#* 4-4181%5* *WPSZ 4-4%8%6- -JHIU"MNPOE 4-4181%#( 4-4181%5( (SBZ Blank Catalog Number Toggle Catalog Number Description 8IJUF 4-4%8%6( (SBZ 4-4181%#- 4-4181%5- -JHIU"MNPOE 4-4%8%6# #MBDL 4-4181%## 4-4181%5# #MBDL 10 OCCUPANCY SENSORS + CEILING MOUNTED OCCUPANCY SENSORS Ceiling Mounted Occupancy Sensor PIR $FJMJOH.PVOUFE1BTTJWF*OGSBSFE1*3 0DDVQBODZ4FOTPSBDDVSBUFMZEFUFDUT PDDVQBODZBOEBVUPNBUJDBMMZTXJUDIFTMJHIUJOHPOBOEPGGBTOFFEFE5IJTMPXQSPýMF sensor is ceiling mounted for superior motion detection. 8JUIBEFHSFFýFMEPGWJFXBOEVQUPTRVBSFGFFUTRNFUFST PG DPWFSBHFBSFBUIF4DIOFJEFS&MFDUSJD$FJMJOH.PVOUFE1*30DDVQBODZ4FOTPSJTJEFBM GPSPGýDFTCSFBLSPPNTBOEDPQJFSSPPNT $FJMJOHNPVOUTFOTPSTBMTPJODPSQPSBUFBOJOUFHSBMMJHIUMFWFMTFOTPSUPQSFWFOUMJHIUJOH from switching On when sufficient ambient light is present, such as is commonly found in windowed areas. *OTUBMMBUJPOBOEDPOýHVSBUJPOJTTJNQMF5IFTFOTPSSFBEJMZNPVOUTUPESPQDFJMJOHTBOE features front located adjustments for setting sensitivity and time delay. Features an JTPMBUFESFMBZGPSVTFXJUICVJMEJOHBVUPNBUJPOTFDVSJUZBOE)7"$TZTUFNT Technical Information Product Features $VSSFOU$POTVNQUJPO!7ED N"/PNJOBM 4VQQMZ7PMUBHF 7ED *TPMBUFE3FMBZ"!7ED 3FTJTUJWF 0QFSBUJOH5FNQFSBUVSF ¡'¡$ .BY)VNJEJUZ 3)/PODPOEFOTJOH 4UBOEBSET 6-BOED6--JTUFE'$$1BSU )PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 20 Catalog Number 11 $FJMJOH.PVOUFE0DDVQBODZ Sensor PIR Description 4-4$14 $FJMJOH.PVOUFE1*30DDVQBODZ4FOTPS 4-411 1PXFS1BDLSFRVJSFE 4-441 "VYJMJBSZ3FMBZ tTRGUTRNFUFST coverage area t7BDGPSVTFXJUI#"4TZTUFNT tEFHSFFýFMEPGWJFX t-JHIU-FWFM4FOTJOHGSPNUP 250 foot-candles) t1BUFOUQFOEJOHBEBQUJWF technology employs advanced algorithms to achieve convenient energy savings and reduce lamp and ballast maintenance. t"EKVTUBCMF5JNF%FMBZQSFTFU time delays from 15 seconds UFTU UPNJOVUFT t"EKVTUBCMF4FOTJUJWJUZGSPN UP t*TPMBUFE3FMBZ"BU7ED/0 BOE/$'PSN$3FMBZ t3FE-&%.PUJPO*OEJDBUPS t"EKVTUNFOUDPNQBSUNFOUDPWFS equipped with retention clip t6-D6--JTUFE t.BOVBM#ZQBTT t'JWFZFBSXBSSBOUZ OCCUPANCY SENSORS + CEILING MOUNTED OCCUPANCY SENSORS Ceiling Mounted Occupancy Sensor Ultrasonic 5IF$FJMJOH.PVOUFE6MUSBTPOJD0DDVQBODZ4FOTPSBDDVSBUFMZEFUFDUTPDDVQBODZBOE BVUPNBUJDBMMZTXJUDIFTMJHIUJOH0OBOE0GGBTOFFEFE5IJTMPXQSPýMFTFOTPSJTDFJMJOH mounted for superior motion detection over partitions and other common obstructions. 8JUIBEFHSFFýFMEPGWJFXBOEVQUPTRVBSFGFFUTRNFUFST PG DPWFSBHFBSFBUIF4DIOFJEFS&MFDUSJD$FJMJOH.PVOUFE6MUSBTPOJD0DDVQBODZ4FOTPSJT ideal for storage rooms, multi-stalled bathrooms and open office areas. $FJMJOHNPVOUTFOTPSTBMTPJODPSQPSBUFBOJOUFHSBMMJHIUMFWFMTFOTPSUPQSFWFOUMJHIUJOH from switching On when sufficient ambient light is present, such as is commonly found in windowed areas. *OTUBMMBUJPOBOEDPOýHVSBUJPOJTTJNQMF5IFTFOTPSSFBEJMZNPVOUTUPESPQDFJMJOHTBOE features front located adjustments for setting sensitivity and time delay. Features an JTPMBUFESFMBZGPSVTFXJUICVJMEJOHBVUPNBUJPOTFDVSJUZBOE)7"$TZTUFNT Technical Information Product Features $VSSFOU$POTVNQUJPO!7ED N"/PNJOBMN"NBYJNVN 1 4VQQMZ7PMUBHF 7ED *TPMBUFE3FMBZ"!7ED 3FTJTUJWF 0QFSBUJOH5FNQFSBUVSF ¡'¡$ .BY)VNJEJUZ 3)/PODPOEFOTJOH 4UBOEBSET 6-BOED6--JTUFE'$$1BSU )PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 20 Catalog Number $FJMJOH.PVOUFE0DDVQBODZ Sensor Ultrasonic tTRGUTRNFUFST coverage area tEFHSFFýFMEPGWJFX t7BDJOQVUGPSVTFXJUICVJMEJOH automation systems t-JHIU-FWFM4FOTJOHGSPNUP 250 foot-candles) t"EKVTUBCMF5JNF%FMBZQSFTFU time delays from 15 seconds UFTU UPNJOVUFT t1BUFOUQFOEJOHBEBQUJWF technology employs advanced algorithms to achieve convenient energy savings and reduce lamp and ballast maintenance. t"EKVTUBCMF4FOTJUJWJUZGSPNUP t*TPMBUFE3FMBZ"BU7ED/0 BOE/$'PSN$3FMBZ t3FE-&%.PUJPO*OEJDBUPS t"EKVTUNFOUDPNQBSUNFOUDPWFS equipped with retention clip t6-D6--JTUFE t.BOVBM#ZQBTT t'JWFZFBSXBSSBOUZ Description 4-4$64 $FJMJOH.PVOUFE6MUSBTPOJD0DDVQBODZ4FOTPS 4-411 1PXFS1BDLSFRVJSFE 4-441 "VYJMJBSZ3FMBZ 12 OCCUPANCY SENSORS + CEILING MOUNTED OCCUPANCY SENSORS Ceiling Mounted Occupancy Sensor Dual Technology 5IF.PVOUFE%VBM5FDIOPMPHZ0DDVQBODZ4FOTPSFNQMPZTCPUIQBTTJWFJOGSBSFE1*3 BOE ultrasonic technology to accurately detect occupancy and automatically turn on lighting. 5PSFEVDFUIFPDDVSSFODFPGGBMTFPOFWFOUTUIJTTFOTPSFNQMPZT1*3UFDIOPMPHZUP detect major motion. Once lighting has been turned on, it employs highly sensitive PIR and VMUSBTPOJDUFDIOPMPHZUPEFUFDUNJOPSNPUJPOBOELFFQMJHIUJOHPOXIJMFUIFBSFBSFNBJOT PDDVQJFE8IFOUIFSPPNPSBSFBJTOPMPOHFSPDDVQJFEUIFTFOTPSUVSOTPGGMJHIUJOHBGUFSB pre-set time delay. 5IFMPXQSPýMFTFOTPSJTDFJMJOHNPVOUFEGPSHSFBUFTUTFOTJUJWJUZUPEFUFDUNPUJPOJOMBSHF BSFBTXJUIPCTUSVDUJPOT8JUIBEFHSFFýFMEPGWJFXBOEVQUPTRVBSFGFFU TRNFUFST PGDPWFSBHFBSFBUIF$FJMJOH.PVOUFE%VBM5FDIOPMPHZ0DDVQBODZ4FOTPSJT ideal for conference rooms, classrooms and large meeting rooms. 5IFTFDFJMJOHNPVOUTFOTPSTBMTPJODPSQPSBUFBOJOUFHSBMMJHIUMFWFMTFOTPSUPQSFWFOUMJHIUJOH from switching On when sufficient ambient light is present, such as is commonly found in windowed areas. %VBM$JSDVJU8BMM4XJUDI Occupancy Sensor *OTUBMMBUJPOBOEDPOýHVSBUJPOJTTJNQMF5IFTFOTPSSFBEJMZNPVOUTUPESPQDFJMJOHTBOE GFBUVSFTGSPOUMPDBUFEBEKVTUNFOUTGPSTFUUJOHTFOTJUJWJUZBOEUJNFEFMBZ5IFTFOTPSBMTP GFBUVSFTBOJTPMBUFESFMBZGPSVTFXJUICVJMEJOHBVUPNBUJPOBOE)7"$TZTUFNT Technical Information Product Features $VSSFOU$POTVNQUJPO N"/PNJOBM 4VQQMZ7PMUBHF 7ED *TPMBUFE3FMBZ "!7ED3FTJTUJWF 0QFSBUJOH5FNQFSBUVSF ¡'¡$ .BY)VNJEJUZ 3)/PODPOEFOTJOH 4UBOEBSET 6-BOED6--JTUFE'$$1BSU )PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 21 Catalog Number 13 Description 4-4$%4 $FJMJOH.PVOUFE%VBM5FDIOPMPHZ0DDVQBODZ4FOTPS 4-411 1PXFS1BDLSFRVJSFE 4-441 "VYJMJBSZ3FMBZ t"WBJMBCMFJOXIJUFJWPSZHSBZMJHIU BMNPOEBOECMBDLXJUINBUDIJOH wall switch cover plate t$PMPSNBUDIJOHNVMUJTFHNFOUFE lens t4FMFDUBCMFBVUPPOBOENBOVBM on modes t1BUFOUQFOEJOHBEBQUJWF technology employs advanced algorithms to achieve convenient energy savings and reduce lamp and ballast maintenance t7BD)[JOQVU t¡ýFMEPGWJFX tTRGUNBKPSNPUJPOBOE TRGUNJOPSNPUJPODPWFSBHF area t-JHIUMFWFMTFOTPS t8BMLUISPVHINPEF t"EKVTUBCMFMJHIUMFWFMUJNFEFMBZ and sensitivity t3FE-&%NPUJPOJOEJDBUPS t'PSVTFXJUIFMFDUSPOJDBOE magnetic ballasts t/POFVUSBMDPOOFDUJPONJOJNVN MPBEPSQPXFSQBDLSFRVJSFE t6-BOED6--JTUFEGPS6OJUFE 4UBUFTBOE$BOBEB t5FTUNPEFTFDPOEUJNFEFMBZ t'JWFZFBSXBSSBOUZ OCCUPANCY SENSORS + CEILING MOUNTED OCCUPANCY SENSORS 180° Ceiling Mounted Occupancy Sensor Ultrasonic and Dual Technology 5IF%FHSFF$FJMJOH.PVOUFE0DDVQBODZ4FOTPSTBSFJEFBMGPSVTFJOCVTJOFTTBOE PGýDFTFUUJOHTUPBDDVSBUFMZEFUFDUPDDVQBODZBOEBVUPNBUJDBMMZDPOUSPMMJHIUJOH5IF ceiling-mount design of these low-profile sensors allows the greatest possible motion TFOTJUJWJUZ"OBEKVTUNFOUQBOFMJTDPOWFOJFOUMZMPDBUFEPOUIFGSPOUPGUIFTFOTPS QSPWJEJOHSFBEZBDDFTTUPTFUUJOHDPOUSPMTBGUFSUIFTFOTPSJTJOTUBMMFE5IFTFPDDVQBODZ TFOTPSTBSFBWBJMBCMFJOUIFVMUSBTPOJDBOEEVBMUFDIOPMPHZNPEFMT5IFEVBMUFDIOPMPHZ model employs passive infrared (PIR) and ultrasonic technology. %FHSFF%VBM5FDIOPMPHZ Occupancey Sensor Technical Information Product Features $VSSFOU$POTVNQUJPO "DUJWFN" *TPMBUFE3FMBZ $POUBDUSBUJOH"!7ED3FTJTUJWF 0QFSBUJOH5FNQFSBUVSF UP¡'UP¡$ .BY)VNJEJUZ UP3)OPODPOEFOTJOH 4UBOEBSET 6-BOED6--JTUFE '$$1BSU)PNFBOE0GýDF6TF$MBTT# $BMJGPSOJB5JUMF$FSUJýFE *For Diagram see technical section page 21 Catalog Number Description 4-4$64 %FHSFF6MUSBTPOJDTFOTPS 4-4$%4 %FHSFF%VBM5FDIOPMPHZ4FOTPS1*3BOE6MUSBTPOJD4FOTPSTDPNCJOFE 4-411 1PXFS1BDLSFRVJSFE 4-441 "VYJMJBSZ3FMBZ[ tTRGUDPWFSBHFBSFB t¡ýFMEPGWJFX t1IUBUFOUQFOEJOHBEBQUJWF technology employs advanced algorithms to achieve convenient energy savings and reduce lamp and ballast maintenance. t"NCJFOUMJHIUMFWFMTFOTJOHGSPN 0.5 to 250 foot-candles t"EKVTUBCMFUJNFEFMBZGSPN TFDUPNJO t"EKVTUBCMFTFOTJUJWJUZGSPN UPTRGUPG maximum coverage) t*TPMBUFESFMBZ'PSN$DPOUBDUT GPS$MBTTTJHOBMMJOH t-&%NPUJPOJOEJDBUPSTVMUSBTPOJD = 1 red, dual technology = 1 red, 1 green) 14 C-BUSTM OCCUPANCY SENSORS + WALL MOUNTED OCCUPANCY SENSORS Wall Mounted Occupancy Sensor PIR 4DIOFJEFS&MFDUSJD8BMM.PVOUFE1BTTJWF*OGSBSFE1*3 0DDVQBODZ4FOTPSBDDVSBUFMZ EFUFDUTPDDVQBODZBOEBVUPNBUJDBMMZTXJUDIFTMJHIUJOHPOBOEPGGBTOFFEFE5IJT sensor is wall or ceiling mounted for superior motion detection. 5IF1*30DDVQBODZ4FOTPSJODMVEFTJOUFSDIBOHFBCMFMFOTFTGPSDVTUPNDPWFSBHF QBUUFSOT5IF8JEF"OHMFMFOTIBTBTRVBSFGPPUDPWFSBHFBSFBXIFOUIFTFOTPSJT NPVOUFEGFFUIJHIUIF-POH3BOHFMFOTIBTBMJOFBSGPPUDPWFSBHFBSFB!GU IJHIBOEUIF)JHI#BZMFOTIBTBMJOFBSGPPUDPWFSBHFBSFB!GUIJHI8JUIB EFHSFFýFMEPGWJFXUIF4DIOFJEFS&MFDUSJD8BMM.PVOUFE1*30DDVQBODZ4FOTPSJTJEFBM for warehouse, business and office settings. 8BMMNPVOUTFOTPSTBMTPJODPSQPSBUFBOJOUFHSBMMJHIUMFWFMTFOTPSUPQSFWFOUMJHIUJOHGSPN switching On when sufficient ambient light is present, such as is commonly found in windowed areas. *OTUBMMBUJPOBOEDPOýHVSBUJPOJTTJNQMF5IFTFOTPSSFBEJMZNPVOUTUPXBMMTBTXFMMBT drop ceilings and features front located adjustments for setting sensitivity and time delay. 'FBUVSFTBOJTPMBUFESFMBZGPSVTFXJUICVJMEJOHBVUPNBUJPOTFDVSJUZBOE)7"$TZTUFNT Technical Information Product Features $VSSFOU$POTVNQUJPO!7ED N"/PNJOBMN"NBYJNVN 1 4VQQMZ7PMUBHF 7ED *TPMBUFE3FMBZ"!7ED 3FTJTUJWF 0QFSBUJOH5FNQFSBUVSF ¡'¡$ .BY)VNJEJUZ 3)/PODPOEFOTJOH 4UBOEBSET 6-BOED6--JTUFE'$$1BSU )PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 21 Wiring Color Table 8JSF$PMPS Functions #MBDL 7ED 7ED Red (SFFO *TPMBUFE$POUBDU/$ Yellow *TPMBUFE$POUBDU$PNNPO Orange *TPMBUFE$POUBDU/0 $POUSPM0VUQVU Blue *For Diagram see technical section page 21 *Control power must be provided by Schneider Electric Power Pack SLSPP1277 or approved equivalent. Confirm the sensor is connected to the Class 2 side of the Power Pack. Refer to the Schneider Electric Power Pack SLSPP1277 Instruction Bulletin for additional information Catalog Number 4-4814 15 8BMM.PVOUFE0DDVQBODZ Sensor PIR Description 8IJUF 4-411 1PXFS1BDLSFRVJSFE 4-441 "VYJMJBSZ3FMBZ t*OUFSDIBOHFBCMFMFOTFTGPS custom coverage pattern t8JEF"OHMFTRGU!GU mounting height t-POH3BOHFMJOFBSGU! ft. mounting height t)JHI#BZMJOFBSGU!GU mounting height t1BUFOUQFOEJOHBEBQUJWF technology employs advanced algorithms to achieve convenient energy savings and reduce lamp and ballast maintenance. tEFHSFFýFMEPGWJFX t-JHIU-FWFM4FOTJOHGSPNUP 250 foot-candles) t"EKVTUBCMF5JNF%FMBZ (pre-set time delays from 15 TFDPOETUPNJOVUFT t"EKVTUBCMF4FOTJUJWJUZGSPNUP t*TPMBUFE3FMBZ t3FE-&%.PUJPO*OEJDBUPS t'SPOUMPDBUFEBEKVTUNFOUBDDFTT cover t6-®D6--JTUFE OCCUPANCY SENSORS + CEILING MOUNTED OCCUPANCY SENSORS Wall Mounted Occupancy Sensor Ultrasonic Schneider Electric®8BMM.PVOUFE6MUSBTPOJD0DDVQBODZ4FOTPSBDDVSBUFMZEFUFDUT PDDVQBODZBOEBVUPNBUJDBMMZTXJUDIFTMJHIUJOHPOBOEPGGBTOFFEFE5IJTMPXQSPýMF sensor is wall or ceiling mounted for superior motion detection over partitions and other common obstructions. 8JUITRVBSFGFFUPGDPWFSBHFBSFBUIF4DIOFJEFS&MFDUSJD® 8BMM.PVOUFE Ultrasonic Occupancy Sensor is ideal for storage rooms, hallways, bathrooms, conference rooms, classrooms and open office areas. 8BMMNPVOUTFOTPSTBMTPJODPSQPSBUFBOJOUFHSBMMJHIUMFWFMTFOTPSUPQSFWFOUMJHIUJOH from switching on when sufficient ambient light is present, such as is commonly found in windowed areas. *OTUBMMBUJPOBOEDPOýHVSBUJPOJTTJNQMF5IFTFOTPSSFBEJMZNPVOUTUPXBMMTPSESPQ ceilings and features front located adjustments for setting sensitivity and time delay. 'FBUVSFTBOJTPMBUFESFMBZGPSVTFXJUICVJMEJOHBVUPNBUJPOTFDVSJUZBOE)7"$TZTUFNT Product Features Technical Information $VSSFOU$POTVNQUJPO N"/PNJOBM 4VQQMZ7PMUBHF 7ED *TPMBUFE3FMBZ "!7ED3FTJTUJWF 0QFSBUJOH5FNQFSBUVSF ¡'¡$ .BY)VNJEJUZ 3)/PODPOEFOTJOH 4UBOEBSET 8BMM.PVOUFE0DDVQBODZ Sensor Ultrasonic 6-BOED6--JTUFE'$$1BSU '$$1BSU)PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 21 Wiring Color Table 8JSF$PMPS Functions #MBDL tTRGUDPWFSBHFBSFB t-JHIU-FWFM4FOTJOHGSPNUP 250 foot-candles) t"EKVTUBCMF5JNF%FMBZ (pre-set time delays from 15 TFDPOETUPNJOVUFT t1BUFOUQFOEJOHBEBQUJWF technology employs advanced algorithms to achieve convenient energy savings and reduce lamp and ballast maintenance. t"EKVTUBCMF4FOTJUJWJUZGSPN UP t*TPMBUFE3FMBZ t3FE-&%.PUJPO*OEJDBUPS t.BOVBM#ZQBTT t'SPOUMPDBUFEBEKVTUNFOUBDDFTT cover t6-®D6--JTUFE 7ED 7ED Red (SFFO *TPMBUFE$POUBDU/$ Yellow *TPMBUFE$POUBDU$PNNPO Orange *TPMBUFE$POUBDU/0 $POUSPM0VUQVU Blue *For Diagram see technical section page 21 *Control power must be provided by Schneider Electric Power Pack SLSPP1277 or approved equivalent. Confirm the sensor is connected to the Class 2 side of the Power Pack. Refer to the Schneider Electric Power Pack SLSPP1277 Instruction Bulletin for additional information Catalog Number 4-4864 Description 8BMM.PVOUFE0DDVQBODZ4FOTPS Ultrasonic 4-411 1PXFS1BDLSFRVJSFE 4-441 "VYJMJBSZ3FMBZ 16 C-BUSTM OCCUPANCY SENSORS + WALL MOUNTED OCCUPANCY SENSORS Wall Mounted Occupancy Sensor Dual Technology Schneider Electric®8BMM.PVOUFE%VBM5FDIOPMPHZ0DDVQBODZ4FOTPSFNQMPZTCPUI passive infrared (PIR) and ultrasonic technology to accurately detect occupancy and automatically turn on lighting. 5PSFEVDFUIFPDDVSSFODFPGGBMTFPOFWFOUTUIJTTFOTPSFNQMPZT1*3UFDIOPMPHZUP detect major motion. Once lighting has been turned on, it employs highly sensitive PIR BOEVMUSBTPOJDUFDIOPMPHZUPEFUFDUNJOPSNPUJPOBOELFFQMJHIUJOHPOXIJMFBSFBTSFNBJO PDDVQJFE8IFOUIFSPPNPSBSFBJTOPMPOHFSPDDVQJFEUIFTFOTPSUVSOTPGGMJHIUJOHBGUFSB pre-set time delay. 5IFMPXQSPýMFTFOTPSJTXBMMNPVOUFEGPSHSFBUFTUTFOTJUJWJUZUPNPUJPOJOMBSHFBSFBTXJUI PCTUSVDUJPOT8JUIBEFHSFFýFMEPGWJFXBOEVQUPTRVBSFGFFUPGDPWFSBHFBSFB XIFONPVOUFEBUGUPGGUIFHSPVOEUIF8BMM.PVOUFE%VBM5FDIOPMPHZ0DDVQBODZ4FOTPS is ideal for conference rooms, classrooms, bathrooms, and large office areas. 5IFTFXBMMNPVOUTFOTPSTBMTPJODPSQPSBUFBOJOUFHSBMMJHIUMFWFMTFOTPSUPQSFWFOUMJHIUJOH from switching On when sufficient ambient light is present, such as is commonly found in windowed areas. 8BMM.PVOUFE0DDVQBODZ4FOTPS %VBM5FDIOPMPHZ *OTUBMMBUJPOBOEDPOýHVSBUJPOJTTJNQMF5IFTFOTPSSFBEJMZNPVOUTUPXBMMTBOEESPQDFJMJOHT BOEGFBUVSFTGSPOUMPDBUFEBEKVTUNFOUTGPSTFUUJOHTFOTJUJWJUZBOEUJNFEFMBZ5IFTFOTPSBMTP GFBUVSFTBOJTPMBUFESFMBZGPSVTFXJUICVJMEJOHBVUPNBUJPOBOE)7"$TZTUFNT Technical Information Product Features $VSSFOU$POTVNQUJPO N"/PNJOBM 4VQQMZ7PMUBHF 7ED *TPMBUFE3FMBZ "!7ED3FTJTUJWF 0QFSBUJOH5FNQFSBUVSF ¡'¡$ .BY)VNJEJUZ 3)/PODPOEFOTJOH 4UBOEBSET 6-BOED6--JTUFE'$$1BSU '$$1BSU)PNFBOE0GýDF6TF$MBTT# 5JUMF$FSUJýFE *For Diagram see technical section page 22 Wiring Color Table 8JSF$PMPS Functions #MBDL 7ED 7ED Red (SFFO *TPMBUFE$POUBDU/$ Yellow *TPMBUFE$POUBDU$PNNPO Orange *TPMBUFE$POUBDU$PNNPO $POUSPM0VUQVU Blue *For Diagram see technical section page 22 *Control power must be provided by Schneider Electric Power Pack SLSPP1277 or approved equivalent. Confirm the sensor is connected to the Class 2 side of the Power Pack. Refer to the Schneider Electric Power Pack SLSPP1277 Instruction Bulletin for additional information Catalog Number 4-48%4 17 Description 8BMM.PVOUFE0DDVQBODZ4FOTPS %VBM5FDIOPMPHZ 4-411 1PXFS1BDLSFRVJSFE 4-441 "VYJMJBSZ3FMBZ tTRGUDPWFSBHFBSFB!GU tEFHSFFýFMEPGWJFX t-JHIU-FWFM4FOTJOHGSPNUP 250 foot-candles) t"EKVTUBCMF5JNF%FMBZ (pre-set time delays from 15 TFDPOETUPNJOVUFT t1BUFOUQFOEJOHBEBQUJWF technology employs advanced algorithms to achieve convenient energy savings and reduce lamp and ballast maintenance. t"EKVTUBCMF4FOTJUJWJUZGSPN UP t*TPMBUFE3FMBZ t3FEBOEHSFFO-&%NPUJPO indicators t.BOVBM#ZQBTT t'SPOUMPDBUFEBEKVTUNFOUBDDFTT cover t6-®D6--JTUFE OCCUPANCY SENSORS + POWER PACK AND AUXILIARY RELAY Power Pack and Auxiliary Relay 5IF1PXFS1BDLTVQQMJFTMPXWPMUBHFQPXFSUP4DIOFJEFS&MFDUSJDDFJMJOHBOEXBMM NPVOUFEPDDVQBODZTFOTPSTBOEFNQMPZTBIFBWZEVUZ"SFMBZUPTXJUDIMJHIUJOHBOE )7"$MPBETCBTFEPOBDPOUSPMTJHOBMSFDFJWFEGSPNUIFPDDVQBODZTFOTPS5IFQPXFS QBDLBDDFQUTCPUI7BOE7JOQVUBOETVQQMJFTVQUPN"BU7ED 5IFQPXFSQBDLFNQMPZTBNJDSPDPOUSPMMFSUIBUTXJUDIFTMPBETBUNJOJNVNWPMUBHF protecting relay contacts from high in-rush current common when switching electronic CBMMBTUT5IJTTXJUDIJOHNFUIPESFEVDFTUIFTUSFTTBDSPTTUIFSFMBZDPOUBDUTQSFWFOUJOH arc-over and assuring long reliable contact life. 4JNJMBSUPUIFQPXFSQBDLUIFBVYJMJBSZSFMBZEPFTOPUTVQQMZQPXFSCVUTXJUDIFT MJHIUJOHBOE)7"$MPBETCBTFEPOBDPOUSPMTJHOBMGSPNUIFPDDVQBODZTFOTPS #PUIUIFQPXFSQBDLBOEBVYJMJBSZSFMBZBSFIPVTFEJOBSVHHFEQMFOVNSBUFEFODMPTVSF 'MFYJCMFNPVOUJOHTDIFNFBMMPXTGPSJOTUBMMBUJPOJOTJEFPSPVUTJEFBTUBOEBSEYJODI junction box. 1PXFS+BDL Technical Information Product Features 1PXFS1BDL Item "VYJMJBSZ3FMBZ 4UPSBHF5FNQ -20¡F to 150¡'$UP$ ¡F to 150¡'$UP$ 0QFSBUJOH5FNQFSBUVSF ¡'UP¡'$UP$ ¡'UP¡'$UP$ .BY)VNJEJUZ *OQVU 3)/PODPOEFOTJOH3)/PODPOEFOTJOH PS7BD)[ 0VUQVU .BY-PBE3BUJOHT 7EDN" 7EDN"/PNJOBM/P1PXFS4VQQMZ 7BD)[7BD)[7BD)[7BD)[ 5VOHTUFO "8"8"8"8 #BMMBTU """" "$.PUPS %JNFOTJPOT t77*OQVU t1MFOVN3BUFE t'MFYJCMF.PVOUJOH0QUJPOT t6-BOED6--JTUFE t'$$1BSU$MBTT# t)FBWZEVUZSFMBZSBUFEUPTXJUDI electronic ballast loads t&YUFSOBMDPMPSDPEFEMFBETGPS RVJDLJOTUBMMBUJPO t.PVOUTUPBTUBOEBSEJO NN YJONN KVODUJPO box using a ½ in. (12.7 mm) UISFBEFE&.5OJQQMF )1BU7BD/P)1SBUJOHBU7BD JONN UBMMYJONN XJEFYJONN EFFQ *For Diagram see technical section page 22 Catalog Number Description 4-411 0DDVQBODZ4FOTPS1PXFS1BDL 4-441 0DDVQBODZ4FOTPS"VYJMJBSZ3FMBZ 18 OCCUPANCY SENSORS + HIGH BAY OCCUPANCY SENSORS High Bay Occupancy Sensor HID 4DIOFJEFS&MFDUSJD)JHI#BZ)*%#BTJD4JOHMFBOE%VBM0VUQVU0DDVQBODZ4FOTPST XPSLXJUIBTJOHMF)*%IJHIJOUFOTJUZEJTDIBSHF MVNJOBJSFUPSFEVDFUIFMBNQXBUUBHF CZBQQSPYJNBUFMZBOEUIFOSFUVSOUIFMBNQXBUUBHFUPXIFOPDDVQBODZJT EFUFDUFEJOBOBJTMFPSSPPN.PUJPOJTEFUFDUFEVTJOHQBTTJWFJOGSBSFE1*3 UFDIOPMPHZ #BTJD)*%4FOTPSTBSFVTFEJOTFOTPSQFSýYUVSFDPOýHVSBUJPOXIJMFTJOHMFPVUQVU sensors include a connector to send and receive fiber optic signals. Single output TFOTPSTBSFDPNNPOMZVTFEJOEBJTZDIBJODPOýHVSBUJPOT%VBMPVUQVUTFOTPSTIBWFUXP connectors that send fiber optic signals, and are commonly used in configurations that JOUFSMFBWFTXJUDIQBDLTBOETFOTPST"MM4FOTPSTBSFDPNQBUJCMFXJUITJOHMFNBHOFUJD )*%MVNJOBJSFT )JHI#BZ0DDVQBODZ4FOTPS Sensor and optional counterweight mounted on luminaire Technical Information 'JYUVSF$PNQBUJCJMJUZ Product Features )*%XJUIDPOTUBOUXBUUBHFBVUPUSBOTGPSNFSCBMMBTU %JNNJOH.FUIPE 3FMBZTXJUDIFEEVBMTFDUJPODBQBDJUPS 4XJUDIJOH$POýHVSBUJPOT 1BSBMMFMQSFGFSSFE PSTFSJFTDBQBDJUPST 3FMBZ$VSSFOU3BUJOH BNQFSFT3.4NBYJNVN .BYJNVN'JYUVSF8BUUBHF XBUUTQBSBMMFMNPEFXBUUTTFSJFTNPEF "$-JOF7PMUBHF 7"$ 1PXFS$POTVNQUJPO XBUUTNBYJNVN .BYJNVN'JCFS4QBDJOH Between Nodes GU "NCJFOU5FNQFSBUVSF3BOHF 0UP0'0UP0$ OPODPOEFOTJOH 0CTFSWFE.PUJPO0/5JNF UPNJOVUFTVTFSBEKVTUBCMF -BNQ8BSN6Q*OUFSWBM NJOVUFT 8JSF)BSOFTT DPOEVDUPS"8(TUSBOEFEDPQQFSXJSF 8JSF)BSOFTT-FOHUI JODIFTDN %JNFOTJPOT JODMVEJOHNPVOUJOHOJQQMF JO- YJO8 YJO) <NN- YNN8 YNN) > 4UBOEBSET 6-¥-JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOUD6--JTUFE *For Diagram see technical section page 22 19 Catalog Number Description 4-41*1 #BTJD0DDVQBODZ4FOTPS 4-41*1 4JOHMF0VUQVU0DDVQBODZ4FOTPS 4-41*1 %VBM0VUQVU0DDVQBODZ4FOTPS 4-41$8 0QUJPOBM$PVOUFSXFJHIU t$PNQBUJCMFXJUI)*%MVNJOBJSFTSBUFE CFUXFFOBOE7"$)[ without adding taps or jumpers t6QUPNPVOUJOHIFJHIU t6TFSBEKVTUBCMFUPNJOVUFBDUJWJUZ timer t6TFSBEKVTUBCMFSBOHFEJBMUP customize PIR sensitivity t"WBJMBCMFXJUIJOUFSDIBOHFBCMFBJTMF and area lenses t-BNQBMXBZTTUBSUTPOIJHIUPQSPWJEF GVMMSBUFE)*%MBNQMJGFFWFOBGUFS"$ power bumps or loss of fiber optic signals t*ODMVEFTBNBOVBMUFTUTXJUDIGPSTFMG diagnostics that assist with installation BOEEFCVHHJOHOFUXPSLT OCCUPANCY SENSORS + TECHNICAL SECTION Wall Switch Occupancy Sensor 35 ft. (10.7 m) 4 ft. (31.2 m) Auto 35 ft. (10.7 m) 10 ft. (3.1 m) 15 ft. (4.6 m) 25 ft. (7.6 m) Sensor field of view Sensor features Commercial Grade Occupancy Sensors PIR Wall Switch 35 ft. (10.7 m) 6 ft. (1.83 m) 9 ft. (2.74 m) 4FOTPS8JSJOH%VBM$JSDVJU 4FOTPS8JSJOH#JMFWFM 21 ft. (6.4 m) 4 ft. (1.2 m) 35 ft. (10.7 m) Side view of sensor field of view 27ft. (8.23m) 20ft. (6.1m) Commercial Grade Occupancy Sensors Ultrasonic Wall Switch 20ft. (6.1m) 27ft. (8.23m) 4FOTPS8JSJOH 4FOTPS8JSJOH#JMFWFM 4FOTPS8JSJOH%VBM$JSDVJU 6MUSBTPOJD4FOTPS'JFMEPG7JFX5PQ 20 OCCUPANCY SENSORS + TECHNICAL SECTION Commercial Grade Occupancy Sensors Dual Technology Wall Switch 4 ft. 35 ft. 27 ft. 35 ft. (10.67 m) %VBM5FDIOPMPHZ4FOTPS'JFMEPG7JFX4JEF (8.23 m) (6.1 m) 20 ft. 10 ft. (3.05 m) (10.67m) (1.22 m) 6 ft. (1.83 m) 13.5 ft. 9 ft. (4.11 m) (2.74 m) 21 ft. (6.4 m) 4FOTPS8JSJOH#JMFWFM 4JOHMFBOE%VBM5FDIOPMPHZ4FOTPS'JFMEPG7JFX5PQ 4FOTPS8JSJOH%VBM$JSDVJU Ceiling Mounted Occupancy Sensor PIR 4.5 in. (115 mm) 9 ft. (2.74 m) 1.75 in. (44 mm) 25 ft. (7.62 m) (7.62 m) 32 ft. (9.75 m) (9.75 m) 25 ft. (7.62 m) (7.62 m) Side view of sensor field of view m) 32 ft. (9.75 (9.75 m) 180˚Ceiling Mounted Occupancy Sensor PIR Class 1 21 5PQWJFXPGTFOTPSýFMEPGWJFX Red Blue Black Blue Black Red Green (N.C.) Yellow (Common) Load 5PQWJFXPGTFOTPSýFMEPGWJFX Red Black White Power Pack SLSPP1277 Red Orange (N.O.) Hot Neutral Blue Black Class 2 Additional Sensor(s) (optional) Contact rating: 1A @ 24 Vdc Resistive OCCUPANCY SENSORS + TECHNICAL SECTION Ceiling Mounted Occupancy Sensor Ultrasonic IW 0DMRU0RWLRQ IW Side view of ceiling mounted sensor 0LQRU0RWLRQ IW IW 1.25 in. (31 mm) $UHDRI'HWHFWLRQ Ceiling Mounted Occupancy Sensor Dual Technology 48 ft. IW 30 ft. IW 4.5 in. (115 mm) 24 ft. 42 ft. IW IW 8OWUDVRQLF0DMRU0RWLRQ 6MUSBTPOJD.BKPS.PUJPO 8OWUDVRQLF0LQRU0RWLRQ 6MUSBTPOJD.BKPS.PUJPO 3,50DMRU0RWLRQ 1*3.BKPS.PUJPO 3,50LQRU0RWLRQ 1*3.BKPS.PUJPO 1.75 in. (44 mm) 25 ft. IW 32 ft. IW Wall Mounted Occupancy Sensor PIR 48 25 16 11 0 18ft 18ft (5.49m) (5.49m) 11 16 25 30ft 30ft (9.14m) (9.14m) 10ft (3.1m) 48 0 0 3ft (0.9m) 42ft (12.8m) 102ft (31.1m) 22 OCCUPANCY SENSORS + TECHNICAL SECTION Wall Mounted Occupancy Sensor Ultrasonic 16 11.5 0 11.5 16 23 0 32 Wall Mounted Occupancy Sensor Dual Technology 48 25 16 11 0 11 16 25 48 8 0 0 3 15 23 32 48 72 Power Pack and Auxiliary Relay 3 in. (76 mm) 3 in. (76 mm) 2.25 in. (57 mm) 'MFYJCMF.PVOUJOH 23 'SPOU7JFX%JNFOTJPOT 4ZTUFN%JBHSBN OCCUPANCY SENSORS + TECHNICAL SECTION High Bay Occupancy Sensors HID 0 Coverage pattern for area / aisle lenses (side view) $PWFSBHFQBUUFSOGPSBSFBMFOTUPQWJFX $PWFSBHFQBUUFSOGPSBJTMFMFOTUPQWJFX 24 TM C-Bus Lighting Control 25 Introduction to C-BusTM Lighting Control 5IFBWBJMBCJMJUZPGMPXDPTUQPXFSGVM microprocessors for building and home control and management systems has created unprecedented customer expectations for increased control, connectivity and integration of electrical and low-voltage systems. Simple cabling/any topology Sophisticated styling $#VT5. brings a distinctly sophisticated MPPLUPMJHIUJOHBQQMJDBUJPOT$MFBOMJOFT 4MFFLHMBTT&WFSZEFUBJMBOETVSGBDFPGUIFTF LFZQBETBOEUPVDITDSFFOTBSFEFTJHOFEUP complement contemporary commercial and residential environments. System simplicity 8JUIJUTVOJRVFEJTUSJCVUFEDPOUSPMTZTUFN JOTUBMMBUJPODPVMEOUCFFBTJFS:PVDBOQMBDF relays and dimmers in various locations BOEDPOOFDUUIFNEJSFDUMZUPUIFOFUXPSLo FMJNJOBUJOHUIFOFFEUPSVODBCMFCBDLUPB separate enclosure near centrally located processors. Keeping the design simple also adds up to greater system reliability. C-Bus keypads 5IFTFBFTUIFUJDBMMZQMFBTJOHGBDFQMBUFT MFOEBTPQIJTUJDBUFEMPPLUPWJSUVBMMZBOZ TQBDF5IFZSFBTFMFHBOUBTUIFZBSF well-engineered. 4JODFUIF$#VTTZTUFNVTFTTUBOEBSE $BUDBCMJOHVTJOHBOZUPQPMPHZUIFSFTOP TQFDJBMDBCMFUPPSEFSPSLFFQJOTVQQMZ 4PJUTNVDIFBTJFSUPBEESFTTMBTUNJOVUF change orders or to complete a job without wondering if you have the right materials on hand. Fully-scalable solution 8IFUIFSZPVSFDSFBUJOHBMJHIUJOHDPOUSPM system for a single room or a whole facility, Schnieder Electric lighting control offers scalable systems to fit your exact needs. 0VS$#VTTPMVUJPOTBSFEFTJHOFEBSPVOE the size and requirements of your BQQMJDBUJPO"MMUIJTXJUIBDPNNPOQMBUGPSN BOEFBTZJOTUBMMBUJPOQSBDUJDFT5BMLBCPVU þFYJCJMJUZ C-Bus touch screens Our unified wall-mounted panels allow you to control lighting systems and accessories XJUIUIFUPVDIPGBýOHFS%FTJHOFEXJUI WFSTBUJMJUZJONJOEUIFTFTMFFLUPVDITDSFFOT are easy to install, customize and use. 5IFZSFDPNQBDUZFUQPXFSGVM4JNQMFUP PQFSBUFZFUIJHIMZþFYJCMF"EFTLUPQNPEFM is available when wall space is limited or for added convenience. 26 C-BUSTM LIGHTING CONTROL + KEYPADS Neo™ Keypads 5IF$#VT5. Neo™ Keypads offer localized finger-tip control of lighting and other FMFDUSJDBMEFWJDFT8JUIPWFSDVTUPNDPMPSDPNCJOBUJPOTBWBJMBCMFUIFTFFMFHBOU LFZQBETBSFTVJUBCMFGPSWJSUVBMMZBOZEFDPS 0OFDPNQBDU/FPLFZQBEDBOUBLFUIFQMBDFPGNBOZTJOHMFTXJUDIFT0/0''UPHHMFT EJNNFSTBOEUJNFST"WBJMBCMFJOZPVSDIPJDFPGBUXPGPVSPSFJHIUCVUUPOLFZQBE /FPTNPEFSOTUZMFJTDPNQMFNFOUFECZPSBOHFBOECMVF-&%TUIBUJOTUBOUMZTIPXUIF status of controlled devices. /FP4UZMF#VUUPO,FZQBE Technical Information 7PMUBHF3FRVJSFNFOUT Product Features o7ED!N"SFRVJSFEGPSOPSNBMPQFSBUJPO ESBXOGSPNUIF$#VTOFUXPSL /VNCFSPG6OJUTPOB/FUXPSL$BMDVMBUFEXJUIUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZVTFEUP FWBMVBUFUIFUPUBMOFUXPSLDVSSFOUMPBE &MFDUSJDBM*TPMBUJPO L73.4GSPN$#VTUPQPXFSQSPWJEFEFYUFSOBMMZ $POUSPM'VODUJPOT -PBETXJUDIJOHEJNNJOHUJNJOHTDFOFDPOUSPM 4UBUVT*OEJDBUPST 5XPDPMPSPSBOHFBOECMVF VTFSDPOýHVSBCMF-&%T -PDBUPS0QUJPO 6TFSDPOýHVSBCMFBEKVTUBCMFCMVF-&%JMMVNJOBUJPOGPSMPDBUJOH UIFVOJUJOEBSLOFTTXJUIiJHOPSFýSTUCVUUPOQSFTTwPQUJPO 4DFOF$POUSPM 5SJHHFSVQUPFJHIUTDFOFTQFSLFZQBE 5JNFST TFDoISTFDJOUFSWBMT 3FTQPOTF5JNF $#VT$POOFDUJPO NTFDPSMFTT 0OFUFSNJOBMCMPDLUPBDDPNNPEBUFo"8(oNN $"5651DBCMFSFRVJSFE %JNFOTJPOT JO- YJO8 YJO% <NN - YNN8 YNN% > .PVOUJOH $FOUFSTJONN &ODMPTVSF/PU1SPWJEFE 1MBTUFSNVESJOH3BDPPSFRVBM X minimum internal width 2.05 in. (52 mm) (not provided) 4JOHMFHBOHCPY$BSMPO"%$"3PSFRVBM XNJOJNVN internal width 2.05 in. (52 mm) (not provided) 8FJHIU P[H 0QFSBUJOH&OWJSPONFOU 5FNQ¡'UP¡'¡$UP¡$ t3)OPODPOEFOTJOH 4UPSBHF&OWJSPONFOU 5FNQ¡'UP¡'o¡$UP¡$ t3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% $PMPS0QUJPOT 4MBUFXIJUFDSFBNHPMECMBDLCSPXO soft gray, desert sand and brushed aluminum ** For additional ordering information see technical section page 95 0SEFSOVNCFSTGPSUIF/FP,FZQBEBTTFNCMJFTJOEJDBUFUIFOVNCFSPGCVUUPOTEFTJSFEPOUIFLFZQBEBOEUIFDPMPSPGFBDIDVTUPNJ[BCMF DPNQPOFOUJOOFSTVSSPVOEPVUFSTVSSPVOEBOECVUUPODPWFS $PMPSOVNCFSTBSFUBLFOGSPNUIFi/FP$PMPSTwUBCMFQBHF BOENVTU CFHJWFOJOUIFGPMMPXJOHPSEFSPVUFSTVSSPVOEJOOFSTVSSPVOEBOECVUUPODPWFST Functional Aesthetics t$MFBOMJOFEMPXQSPýMFLFZQBETBSFXBMM mounted without external fittings t0QUJPOBMCVUUPODPWFSTIBWF*%XJOEPXT FOBCMJOHRVJDLJEFOUJýDBUJPOPGMJHIUJOH scenes or controlled devices (Sold Separately) t%JTUJODUJWFMZEFTJHOFENVMUJMBZFSDPWFS plate consists of button covers, an outer surround, and an inner surround t$PMPSTDIFNFTBSFFBTJMZDVTUPNJ[FEBOE modified to suit personal taste or the decor Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t$POýHVSFECZVTJOH-FBSO.PEFPSB personal computer connected to the OFUXPSL Catalog Number Description 4-$/- /VNCFSPG#VUUPOT /FP,FZQBE"TTFNCMZ#VUUPO$PWFST4-$/31 CVUUPOLFZQBETQBDL #VUUPO$PWFST4-$/3* XJUI*%8JOEPXT 4-$/- /VNCFSPG#VUUPOT 4-$/- /VNCFSPG#VUUPOT 27 t#VUUPODPOýHVSBUJPOTJODMVEFNVMUJQPJOU switching and dimming, master ON/OFF switching, and scene settings t#VJMUJOTDFOFTUPSBHFGPSVQUP controllable addresses with remote scene triggering capabilities t*OEFQFOEFOUUJNFSTBWBJMBCMFGPSFBDI button t4UBOEBSECVJMUJOJOGSBSFESFDFJWFSQFSNJUT LFZQBEDPOUSPMBUBEJTUBODFXJUIBO optional infrared handheld remote (Sold Separately) t%VBMDPMPS-&%XJOEPXTPOFBDI button can glow in cool blue, orange, or combinations of both, indicating when a controlled device is ON or OFF t"VUPiGBMMCBDLwDBOEJNCVUUPO-&%TBUB TFUUJNFBGUFSUIFMBTULFZQSFTT t-PDBUPS-&%TDBOJMMVNJOBUFUIFUPQBOE bottom of the button area in cool blue, IFMQJOHBVTFSýOEUIFLFZQBEJOEJNMJHIU PSCVUUPOT #VUUPO$PWFST4-$/31 CVUUPOLFZQBETQBDL *OOFS4VSSPVOE4-$*4 QBDLPG #VUUPO$PWFST4-$/31 CVUUPOLFZQBETQBDL 0VUFS4VSSPVOE4-$04 QBDLPG C-BUSTM LIGHTING CONTROL + KEYPADS SaturnTM Keypads 5IF$#VT5. Saturn5. Keypads offer localized finger-tip control of lighting and electrical TFSWJDFT5IFTFFMFHBOULFZQBETJODPSQPSBUFBVOJRVFHMBTTDPWFSQMBUFUIBUJTFBTZUP install, customize, and use. #ZWJSUVFPGUIFWBSJFUZPGCVUUPODPOýHVSBUJPOTBWBJMBCMFPOFDPNQBDU4BUVSOLFZQBE DBOUBLFUIFQMBDFPGNBOZTJOHMFPQFSBUJPOTXJUDIFT0/0''UPHHMFTEJNNFSTBOE timers. "WBJMBCMFJOBUXPGPVSPSTJYCVUUPOLFZQBE4BUVSOTNPEFSOTUZMFJTDPNQMFNFOUFE CZPSBOHFBOECMVF-&%TUIBUDBOJOTUBOUMZTIPXUIFTUBUVTPGDPOUSPMMFEEFWJDFT 4BUVSO4UZMF#VUUPO,FZQBE Technical Information 7PMUBHF3FRVJSFNFOUT Product Features o7ED!N"SFRVJSFEGPSOPSNBMPQFSBUJPO ESBXOGSPNUIF$#VTOFUXPSL /VNCFSPG6OJUT POB/FUXPSL %FUFSNJOFEXJUIUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZ VTFEUPFWBMVBUFUIFUPUBMOFUXPSLDVSSFOUMPBE &MFDUSJDBM*TPMBUJPO L73.4GSPN$#VTUPQPXFSQSPWJEFEFYUFSOBMMZ $POUSPM'VODUJPOT -PBETXJUDIJOHEJNNJOHUJNJOHTDFOFDPOUSPM 4UBUVT*OEJDBUPST 5XPDPMPSPSBOHFBOECMVF VTFSDPOýHVSBCMF-&%T -PDBUPS 0QUJPO 6TFSDPOýHVSBCMFBEKVTUBCMF-&%UPIFMQMPDBUFUIFVOJUJO EBSLOFTTIBTiJHOPSFýSTUCVUUPOQSFTTwPQUJPO 4DFOF$POUSPM 5SJHHFSVQUPTJYTDFOFTQFSLFZQBE 5JNFST TFDoISTFDJOUFSWBMT 3FTQPOTF5JNF NTFDPSMFTT $#VT$POOFDUJPO %JNFOTJPOT 0OFUFSNJOBMCMPDLUPBDDPNNPEBUF"8( oNN $"5651DBCMFSFRVJSFE JO- YJO8 YJO% <NN- YNN8 YNN% > .PVOUJOH 1MBTUFSNVESJOH3BDPPSFRVBM X minimum internal width 2.05 in. (52 mm) (not provided) 4JOHMFHBOHCPY$BSMPO"%$"3PSFRVBM XNJOJNVN internal width 2.05 in. (52 mm) (not provided) 8FJHIU P[H 0QFSBUJOH&OWJSPONFOU 4UBOEBSET 5FNQ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 6--JTUFE&OFSHZ.BOBHFNFOU$4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF&/*NNVOJUZUP&4% $PMPS0QUJPOT 8IJUF#MBDL.PDIB$SFBN *For Diagram see technical section page 95 t#VUUPODPOýHVSBUJPOTJODMVEFNVMUJQPJOU switching and dimming, master ON/OFF switching, and scene settings t#VJMUJOTDFOFTUPSBHFGPSVQUP controllable addresses with remote scene triggering capabilities t*OEFQFOEFOUUJNFSTBWBJMBCMFGPSFBDICVUUPO t%VBMDPMPS-&%XJOEPXTPOFBDI button can glow in cool blue, orange, or combinations of both, indicating when a controlled device is ON or OFF t"VUPiGBMMCBDLwDBOEJNCVUUPO-&%TBUB set time after the last button press t-PDBUPS-&%DBOJMMVNJOBUFUIFLFZQBE helping a user find it in dim light Functional Aesthetics t%JTUJODUJWFMZEFTJHOFEUSBOTQBSFOUJNQBDU resistant glass cover plate with silver buttons that can glow blue or orange t$MFBOMJOFELFZQBETBSFXBMMNPVOUFE without external fittings t-PXQSPýMFLFZQBEFYUFOETPOMZJOPVU from the wall t$PMPSTBSFFBTJMZNPEJýFEUPTVJUQFSTPOBM UBTUFPSUIFEÏDPS t0QUJPOBMCVUUPODPWFSTXJUIMBCFMTFOBCMJOH RVJDLJEFOUJýDBUJPOPGMJHIUJOHTDFOFTPS controlled devices Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t$POýHVSFECZVTJOH-FBSO.PEFPSB personal computer connected to the OFUXPSL 0SEFSOVNCFSTGPSUIF4BUVSOLFZQBEBTTFNCMJFTJOEJDBUFUIFOVNCFSPGCVUUPOTEFTJSFEPOUIFLFZQBEBOEUIFDPMPSPG UIFDPWFSQMBUF8IJUF8& #MBDLBK .PDIB#3 $SFBN$. 'PSFYBNQMF4-$/-#,SFQSFTFOUTBOPSEFSGPSB4BUVSOLFZQBEXJUITJYCVUUPOTBOEBCMBDLDPWFSQMBUF5IFPSEFS OVNCFSGPSBUXPCVUUPOLFZQBEJONPDIBXPVMECF4-$/-#3 Catalog Number Description 4-$/- /VNCFSPG#VUUPOT 4BUVSO,FZQBE"TTFNCMZ4-$-$ 4-$/- /VNCFSPG#VUUPOT PSCVUUPOT 1SFMBCFMFECVUUPODBQTFBPGGSFRVFOUMZVTFEMBCFMTTVDIBT-PVOHF.FFUJOH4DFOFFUD 4-$/- /VNCFSPG#VUUPOT 28 C-BUSTM LIGHTING CONTROL + KEYPADS Neo™ Keypads with Dynamic Labeling Technology™ 5IF$#VT5./FP,FZQBETXJUI%ZOBNJD-BCFMJOH5FDIOPMPHZ%-5 DPNCJOFB /FPTUZMFDPWFSQMBUFQSPHSBNNBCMFLFZQBECVUUPOTBOEFBTJMZDVTUPNJ[FEMBCFMTPOB CBDLMJU-$%TDSFFOUIBUFMJNJOBUFTUIFOFFEGPSDVTUPNMBCFMT 5IFTFLFZQBETBSFEFTJHOFEUPCFFBTZUPJOTUBMMDVTUPNJ[FBOEVTF#ZWJSUVFPGUIF WBSJFUZPGCVUUPODPOýHVSBUJPOTBWBJMBCMFPOFDPNQBDU%-5LFZQBEDBOUBLFUIFQMBDFPG many single operation switches, ON/OFF toggles, dimmers, and timers. $PPMCMVF-&%TMJHIUUIFýWFLFZQBECVUUPOTDPNQMFNFOUJOHUIFLFZQBETTMFFLMJOFT and instantly showing the status of controlled devices. /FP4UZMF%-5,FZQBE Technical Information 7PMUBHF 3FRVJSFNFOUT Product Features o7ED!N"SFRVJSFEGPSOPSNBMPQFSBUJPO ESBXOGSPNUIF$#VTOFUXPSL /VNCFSPG6OJUT POB/FUXPSL 6TFUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZUPEFUFSNJOF UIFUPUBMOFUXPSLDVSSFOUMPBE &MFDUSJDBM*TPMBUJPO L73.4GSPN$#VTUPQPXFSQSPWJEFEFYUFSOBMMZ $POUSPM'VODUJPOT -PBETXJUDIJOHEJNNJOHUJNJOHTDFOFDPOUSPM 4UBUVT*OEJDBUPST #MVFPOFEJNNBCMF-&%QFSCVUUPO #BDLMJHIU -PDBUPS 0QUJPO 8IJUFEJNNBCMFVTFSDPOýHVSBCMF 6TFSDPOýHVSBCMFBEKVTUBCMFCMVF-&%GPSMPDBUJOHUIFVOJUJOEBSLOFTT XJUIiJHOPSFýSTUCVUUPOQSFTTwPQUJPO 4DFOF$POUSPM 5SJHHFSVQUPFJHIUTDFOFTQFSLFZQBE 5JNFST TFDoISTFDPOEJOUFSWBMT 4DSFFO YQJYFMT-$% 3FTQPOTF5JNF $#VT$POOFDUJPO %JNFOTJPOT .PVOUJOH NTFDPSMFTT 0OFUFSNJOBMCMPDLUPBDDPNNPEBUFo"8(oNN $"5651DBCMFSFRVJSFE JO- YJO8 YJO% <NN- YNN8 YNN% > 4UBOEBSEQMBTUFSNVE SJOHPSXBMMCPYOPUQSPWJEFE NJOJNVNJOUFSOBM XJEUIJONN $FOUFSTJONN 8FJHIU 0QFSBUJOH&OWJSPONFOU P[H 5FNQ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 95 0SEFSOVNCFSTGPSUIF/FP%-5LFZQBEBTTFNCMJFTJOEJDBUFUIFDPMPSPGUIFDPWFSQMBUF8IJUF8& #SVTIFE"MVNJOVN BOE4MBUF(# 4PGU(SFZ4( $SFBN$. %FTFSU4BOE%4 &YBNQMF0SEFSOVNCFS4-$%-8& SFQSFTFOUTB/FP%-5LFZQBEJOXIJUF 29 t#VUUPODPOýHVSBUJPOTJODMVEFNVMUJQPJOU switching and dimming, master ON/OFF switching, and scene settings t,FZQBETIBWFýWFQIZTJDBMCVUUPOToGPVS control buttons and one scroll/page button– combined with two screens of labels, for a total of eight control buttons and two scroll/ page buttons t#VJMUJOTDFOFTUPSBHFGPSVQUP controllable addresses with remote scene triggering capabilities t*OEFQFOEFOUUJNFSTBWBJMBCMFGPSFBDICVUUPO t#VUUPO-&%TDBOCFVTFEBTMPDBUPSMJHIUTJO UIFEBSL t5JNFDMPDLDBOCFEJTQMBZFEBUUIFCPUUPN of the screen t%JTQMBZTVQUPMBOHVBHFTGSPNBTFUPG NPSFUIBO Catalog Number Description 4-$%- /FP%-5,FZQBE Functional Aesthetics tYQJYFM-$%TDSFFOXJUIBXIJUF CBDLMJHIU t&EJUBCMF-$%MBCFMTBWBJMBCMFGPSFBDI button or control group, can display text, symbols, and graphics t%ZOBNJDHSBQIJDEJTQMBZTTVDIBTCBS graphs, can be enabled or disabled t#JUNBQTDBOCFEPXOMPBEFEGPSFBDIHSPVQ address or scene t$MFBOMJOFEMPXQSPýMFLFZQBETBSFXBMM mounted without external fittings t%JTUJODUJWFUXPMBZFSDPWFSQMBUFDPOTJTUTPG an outer surround and an inner surround Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFECZVTJOH-FBSO.PEF or a personal computer connected to the OFUXPSL C-BUSTM LIGHTING CONTROL + KEYPADS Saturn™ Keypads with Dynamic Labeling Technology™ 5IF$#VT5.4BUVSO%ZOBNJD-BCFMJOH5FDIOPMPHZ%-5 ,FZQBETDPNCJOFB4BUVSO TUZMFHMBTTDPWFSQMBUFQSPHSBNNBCMFLFZQBECVUUPOTBOEFBTJMZDVTUPNJ[FEMBCFMTPOB CBDLMJU-$%TDSFFOUIBUFMJNJOBUFTUIFOFFEGPSDVTUPNMBCFMT 5IFTFLFZQBETBSFEFTJHOFEUPCFFBTZUPJOTUBMMDVTUPNJ[FBOEVTF#ZWJSUVFPGUIF WBSJFUZPGCVUUPODPOýHVSBUJPOTBWBJMBCMFPOFDPNQBDU4BUVSO,FZQBEXJUI%-5DBOUBLF UIFQMBDFPGNBOZTJOHMFPQFSBUJPOTXJUDIFT0/0''UPHHMFTEJNNFSTBOEUJNFST5IF ýWFLFZQBECVUUPOTBSFMJUXJUIDPPMCMVF-&%TUIBUDPNQMFNFOUUIFLFZQBETTMFFLMJOFT and show the status of controlled devices. 4BUVSO4UZMF%-5,FZQBE Technical Information 7PMUBHF3FRVJSFNFOUT Product Features o7ED!N"SFRVJSFEGPSOPSNBMPQFSBUJPOESBXOGSPNUIF$#VTOFUXPSL /VNCFSPG6OJUT POB/FUXPSL 6TFUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZUPEFUFSNJOF UIFUPUBMOFUXPSLDVSSFOUMPBE &MFDUSJDBM*TPMBUJPO L73.4GSPN$#VTUPQPXFSQSPWJEFEFYUFSOBMMZ $POUSPM'VODUJPOT -PBETXJUDIJOHEJNNJOHUJNJOHTDFOFDPOUSPM 4UBUVT*OEJDBUPST #MVFPOFEJNNBCMF-&%QFSCVUUPO #BDLMJHIU -PDBUPS 0QUJPO 8IJUFEJNNBCMFVTFSDPOýHVSBCMF 6TFSDPOýHVSBCMFBEKVTUBCMFCMVF-&%JMMVNJOBUJPOGPSMPDBUJOHUIFVOJU JOEBSLOFTTXJUIiJHOPSFýSTUCVUUPOQSFTTwPQUJPO 4DFOF$POUSPM 5SJHHFSVQUPFJHIUTDFOFTQFSLFZQBE 5JNFST TFDoISTFDPOEJOUFSWBMT 4DSFFO YQJYFMT-$% 3FTQPOTF5JNF $#VT NTFDPSMFTT 0OFUFSNJOBMCMPDLUPBDDPNNPEBUFo"8(oNN2), $POOFDUJPO $"5651DBCMFSFRVJSFE %JNFOTJPOT JO- YJO8 YJO% <NN- YNN8 YNN% > .PVOUJOH 4UBOEBSEQMBTUFSNVE SJOHPSXBMMCPYOPUQSPWJEFE NJOJNVNJOUFSOBM XJEUIJONN $FOUFSTJONN 8FJHIU P[H 0QFSBUJOH&OWJSPONFOU 4UBOEBSET t#VUUPODPOýHVSBUJPOTJODMVEFNVMUJQPJOU switching and dimming, master ON/OFF switching, and scene settings t,FZQBETIBWFýWFQIZTJDBMCVUUPOTGPVS control buttons and one scroll/page buttoncombined with two screens of labels, for a total of eight control buttons and two scroll/ page buttons t#VJMUJOTDFOFTUPSBHFGPSVQUPDPOUSPMMBCMF addresses with remote scene triggering capabilities t*OEFQFOEFOUUJNFSTBWBJMBCMFGPSFBDICVUUPO t#VUUPO-&%TDBOCFVTFEBTMPDBUPSMJHIUTJO UIFEBSL t5JNFDMPDLDBOCFEJTQMBZFEBUUIFCPUUPNPG the screen t%JTQMBZTVQUPMBOHVBHFTGSPNBTFUPG NPSFUIBO 5FNQ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF&/*NNVOJUZUP&4% $PWFS1MBUF$PMPST 8IJUFDSFBNCMBDLNPDIB *For Diagram see technical section page 96 0SEFSOVNCFSTGPSUIF4BUVSO%-5LFZQBETJODMVEFUIFTUPDLOVNCFS4-$%- BOEUIFDPEFGPSUIFDPMPSPGUIFDPWFS QMBUF#MBDL#, .PDIB#3 8IJUF8& BOE$SFBN$. 'PSFYBNQMF4-$%-#3SFQSFTFOUTBDPNQMFUFDBUBMPHOVNCFSGPSB4BUVSO%-5LFZQBEXJUIBNPDIBDPWFSQMBUF Catalog Number Description 4-$%- 4BUVSO,FZQBEXJUI%-5JOXIJUF8& DSFBN$. CMBDL#, PSNPDIB#3 Functional Aesthetics tYQJYFM-$%TDSFFOXJUIBXIJUF CBDLMJHIU t&EJUBCMF-$%MBCFMTBWBJMBCMFGPSFBDICVUUPO or control group, can display text, symbols, and graphics. t%ZOBNJDHSBQIJDEJTQMBZTTVDIBTCBS graphs, can be enabled or disabled t#JUNBQTDBOCFEPXOMPBEFEGPSFBDIHSPVQ address or scene t$MFBOMJOFEMPXQSPýMFLFZQBETBSFXBMM mounted without external fittings Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFECZVTJOH-FBSO.PEFPSB QFSTPOBMDPNQVUFSDPOOFDUFEUPUIFOFUXPSL 30 C-BUSTM LIGHTING CONTROL + KEYPADS Neo™ Decorator Style Keypads 4DIOFJEFS&MFDUSJD$#VT5.%FDPSBUPS4UZMF/FP5. Keypads offer localized finger-tip DPOUSPMPGMJHIUJOHBOEFMFDUSJDBMTFSWJDFT5IFTFFMFHBOULFZQBETJODPSQPSBUFBVOJRVF DPWFSQMBUFPSEFSFETFQBSBUFMZ UIBUJTFBTZUPJOTUBMMDVTUPNJ[FBOEVTF5IFTF %FDPSBUPSTUZMFLFZQBETBSFPSEFSFEXJUIPVUBGBDFQMBUFBOEDBOýUJOBOZFYJTUJOH %FDPSBUPSTUZMFLFZQBEGBDFQMBUF.BUDIJOHGBDFQMBUFTBSFBMTPBWBJMBCMFJOBWBSJFUZPG colors. #ZWJSUVFPGUIFWBSJFUZPGCVUUPODPOýHVSBUJPOTBWBJMBCMFPOFDPNQBDU/FP%FDPSBUPS TUZMFLFZQBEDBOUBLFUIFQMBDFPGNBOZTJOHMFPQFSBUJPOTXJUDIFT0/0''UPHHMFT dimmers, and timers. "WBJMBCMFJOBPOFUXPUISFFPSGPVSCVUUPOLFZQBE/FPTNPEFSOTUZMFJT DPNQMFNFOUFECZPSBOHFBOECMVF-&%TUIBUDBOJOTUBOUMZTIPXUIFTUBUVTPGDPOUSPMMFE devices. /FP#VUUPO%FDPSBUPS4UZMF,FZQBE Technical Information 7PMUBHF o7ED!N"SFRVJSFEGPSOPSNBMPQFSBUJPO 3FRVJSFNFOUT ESBXOGSPNUIF$#VTOFUXPSL /VNCFSPG6OJUT POB/FUXPSL %FUFSNJOFEXJUIUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZ VTFEUPFWBMVBUFUIFUPUBMOFUXPSLDVSSFOUMPBE &MFDUSJDBM*TPMBUJPO L73.4GSPN$#VTUPQPXFSQSPWJEFEFYUFSOBMMZ $POUSPM'VODUJPOT -PDBUPS -PBETXJUDIJOHEJNNJOHUJNJOHTDFOFDPOUSPM 6TFSDPOýHVSBCMFBEKVTUBCMF-&%UPIFMQMPDBUFUIFVOJUJOEBSLOFTT 0QUJPO IBTiJHOPSFýSTUCVUUPOQSFTTwPQUJPO 4DFOF$POUSPM 5SJHHFSVQUPGPVSTDFOFTQFSLFZQBE 5JNFST TFDoISTFDPOEJOUFSWBMT 3FTQPOTF5JNF $#VT$POOFDUJPO %JNFOTJPOT NTFDPSMFTT 0OFUFSNJOBMCMPDLUPBDDPNNPEBUFo"8(oNN $"5651DBCMFSFRVJSFE JO- YJO8 YJO% <NN- YNN8 YNN% > 8FJHIU 0QFSBUJOH&OWJSPONFOU P[H 5FNQ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM '$$1BSU$MBTT#%JHJUBM%FWJDF $PMPS0QUJPOT 4MBUF8IJUF$SFBN#SPXO#MBDL4PGU(SFZ%FTFSU4BOE *For Diagram see technical section page 96 0SEFSOVNCFSTGPSUIF/FP%FDPSBUPSLFZQBETJODMVEFUIFTUPDLOVNCFSUIFOVNCFSPGCVUUPOTUISV BOEUIFDPEFGPS UIFCVUUPODPMPS#MBDL#, #SPXO#3 8IJUF8& $SFBN$. 4MBUF(# 4PGU(SFZ4( BOE%FTFSU4BOE%4 'PSFYBNQMF4-$ /-.8& SFQSFTFOUTB/FP%FDPSBUPSTUZMFLFZQBEXJUICVUUPOTJOXIJUF * Note: Wallplate Sold Separately. Refer to individual product manual for order information. 31 Catalog Number Description 4-$ /-. /FP%FDPSBUPS4UZMF,FZQBE Multi-Functional Capabilities t#VUUPODPOýHVSBUJPOTJODMVEFNVMUJQPJOU switching and dimming, master ON/OFF switching, and scene settings t#VJMUJOTDFOFTUPSBHFGPSVQUP controllable addresses with remote scene triggering capabilities t*OEFQFOEFOUUJNFSTBWBJMBCMFGPSFBDI button t-&%XJOEPXTPOFBDICVUUPODBOHMPX in cool blue or orange, indicating when a controlled device is ON or OFF t"VUPiGBMMCBDLwDBOEJNCVUUPO-&%TBUBTFU time after the last button press t-PDBUPS-&%DBOJMMVNJOBUFUIFLFZQBE helping a user find it in dim light t)BTJOGSBSFESFNPUFDBQBCJMJUJFTXJUI 4DIOFJEFS&MFDUSJD$#VTSFNPUFT Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t$POýHVSFECZVTJOH-FBSO.PEFPS $#VTTPGUXBSF C-BUSTM LIGHTING CONTROL + KEYPADS Saturn™ Decorator Style Keypads 4DIOFJEFS&MFDUSJD$#VT5.%FDPSBUPS4UZMF4BUVSO5. Keypads offer localized finger-tip DPOUSPMPGMJHIUJOHBOEFMFDUSJDBMTFSWJDFT5IFTFFMFHBOULFZQBETJODPSQPSBUFBVOJRVF glass face plate that is aesthetically pleasing with silver buttons that glow blue or amber. "MTPUIFTF%FDPSBUPSTUZMFLFZQBETDBOCFPSEFSFETFQBSBUFMZXJUIPVUBGBDFQMBUFUPýU JOBOZFYJTUJOH%FDPSBUPSTUZMFLFZQBEDPWFSQMBUF #ZWJSUVFPGUIFWBSJFUZPGCVUUPODPOýHVSBUJPOTBWBJMBCMFPOFDPNQBDU4BUVSO%FDPSBUPS TUZMFLFZQBEDBOUBLFUIFQMBDFPGNBOZTJOHMFPQFSBUJPOTXJUDIFT0/0''UPHHMFT dimmers, and timers. "WBJMBCMFJOBPOFUXPUISFFPSGPVSCVUUPOLFZQBE4BUVSOTNPEFSOTUZMFJT DPNQMFNFOUFECZPSBOHFBOECMVF-&%TUIBUDBOJOTUBOUMZTIPXUIFTUBUVTPGDPOUSPMMFE devices. 4BUVSO#VUUPO%FDPSBUPS4UZMF,FZQBE Technical Information Multi-Functional Capabilities 7PMUBHF t#VUUPODPOýHVSBUJPOTJODMVEFNVMUJQPJOU switching and dimming, master ON/OFF switching, and scene settings t#VJMUJOTDFOFTUPSBHFGPSVQUP controllable addresses with remote scene triggering capabilities t*OEFQFOEFOUUJNFSTBWBJMBCMFGPSFBDICVUUPO t4UBOEBSECVJMUJOJOGSBSFESFDFJWFSQFSNJUT LFZQBEDPOUSPMBUBEJTUBODFXJUIBOPQUJPOBM infrared handheld universal remote t%VBMDPMPS-&%XJOEPXTPOFBDICVUUPODBO glow in cool blue, amber, or combinations of both, indicating when a controlled device is ON or OFF t"VUPiGBMMCBDLwDBOEJNCVUUPO-&%TBUBTFU time after the last button press t-PDBUPS-&%DBOJMMVNJOBUFUIFLFZQBE helping a user find it in dim light o7ED!N"SFRVJSFEGPSOPSNBMPQFSBUJPO 3FRVJSFNFOUT ESBXOGSPNUIF$#VTOFUXPSL %FUFSNJOFEXJUIUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZ used to evaluateUIFUPUBMOFUXPSLDVSSFOUMPBE Number of Units POB/FUXPSL &MFDUSJDBM*TPMBUJPO L73.4GSPN$#VTUPQPXFSQSPWJEFEFYUFSOBMMZ $POUSPM'VODUJPOT -PBETXJUDIJOHEJNNJOHUJNJOHTDFOFDPOUSPM 4UBUVT*OEJDBUPST 5XPDPMPSPSBOHFBOECMVF VTFSDPOýHVSBCMF-&%T -PDBUPS 6TFSDPOýHVSBCMFBEKVTUBCMF-&%UPIFMQMPDBUFUIFVOJUJOEBSLOFTT 0QUJPO IBTiJHOPSFýSTUCVUUPOQSFTTwPQUJPO 4DFOF$POUSPM 5SJHHFSVQUPGPVSTDFOFTQFSLFZQBE 5JNFST TFDoISTFDPOEJOUFSWBMT 3FTQPOTF5JNF $#VT$POOFDUJPO %JNFOTJPOT NTFDPSMFTT 0OFUFSNJOBMCMPDLUPBDDPNNPEBUFo"8(oNN $"5651DBCMFSFRVJSFE JO- YJO8 YJO% <NN- YNN8 YNN% > 8FJHIU 0QFSBUJOH&OWJSPONFOU P[H 5FNQ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% $PMPS0QUJPOT Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VT devices t$POýHVSFECZVTJOH-FBSO.PEFPS $#VTTPGUXBSF 8IJUF$SFBN.PDIBBOE#MBDL *For Diagram see technical section page 96 0SEFSOVNCFSTGPSUIF4BUVSO%FDPSBUPSLFZQBETJODMVEFUIFTUPDLOVNCFSUIFOVNCFSPGCVUUPOTUISV BOEUIFDPEF GPSUIFCVUUPODPMPS#MBDL#, .PDIB#3 8IJUF8& BOE$SFBN$. 'PSFYBNQMF4-$ /-.8& SFQSFTFOUTB4BUVSO%FDPSBUPSTUZMFLFZQBEXJUICVUUPOTJOXIJUF * Note: Wallplate Sold Separately. Refer to individual product manual for order information. Catalog Number Description 4-$ /-. 4BUVSO%FDPSBUPS4UZMF,FZQBE 32 C-BUSTM LIGHTING CONTROL + TOUCH SCREENS Mark II Touch Screen 5IF.BSL**5PVDI4DSFFOJTBVOJýFEXBMMNPVOUFEQBOFMGPSDPOUSPMMJOHMJHIUJOHTZTUFNT and accessories with the touch of a finger. %FTJHOFEXJUIWFSTBUJMJUZJONJOEUIFTFTMFFLUPVDITDSFFOTBSFFBTZUPJOTUBMM DVTUPNJ[FBOEVTF$PNQBDUZFUQPXFSGVMUIFUPVDITDSFFOIBTOVNFSPVT DPOýHVSBUJPOTBWBJMBCMFNBLJOHJUBOBUUSBDUJWFBMUFSOBUJWFUPNVMUJQMFTJOHMFPQFSBUJPO switches, ON/OFF toggles, dimmers, and timers which can clutter up even the nicest wall. 4DIOFJEFS&MFDUSJD$#VT5..BSL**UPVDITDSFFOTBSFBWBJMBCMFJOTUBJOMFTTTUFFMBT well as the Saturn™ and Neo™ style cover plates with a wide assortment of colors to choose from. .BSL**5PVDI4DSFFO Technical Information Product Features t. VMUJQMFDPOUSPMTDSFFOTDBOJODMVEFNVMUJ point switching and dimming, master ON/OFF switching, schedules, and scenes from a menu driven interface t" TUSPOPNJDBMDMPDLXJUIGVMMTDIFEVMJOHBOE holidays t' VMMGFBUVSFMPHJDFOHJOFQSPWJEFTBCJMJUZUPDSFBUF DVTUPNDPOUSPMTBOEJOUFHSBUFSEQBSUZEFWJDFT t PDBUPSPQUJPOUPIFMQVTFSTýOEUIFTDSFFOJO dim light t# VJMUJOJOGSBSFESFDFJWFSXSFNPUFDPOUSPM t3 4QPSUGPSUIJSEQBSUZEFWJDFJOUFHSBUJPO t6 4#QSPHSBNNJOHQPSUBDDFTTJCMFGSPNUIFGSPOU of the unit Screen 5ZQF -$%BDUJWFNBUSJY 4J[F JONN EJBHPOBM 3FTPMVUJPO 7("YQJYFMT 7JFXJOH"SFB -FGUSJHIU¡VQ¡EPXO¡ -VNJOBODF DEN 8FJHIU P[H FYDMVEJOHDPWFS 7PMUBHF 3FRVJSFNFOUT o7ED!N"SFRVJSFEGPSOPSNBM PQFSBUJPOESBXOGSPNUIF$#VTOFUXPSL /VNCFSPG6OJUT QFS/FUXPSL %FUFSNJOFEXJUIUIF$#VT$BMDVMBUPS BTPGUXBSFVUJMJUZGPSFWBMVBUJOHUIFUPUBMOFUXPSLDVSSFOUMPBE 34$POOFDUPS $#VT$POOFDUJPO 0WFSBMM%JNFOTJPOT YNNQMVH -PPQJOMPPQPVUSFNPWBCMFUFSNJOBMCMPDLUPBDDPNNPEBUF "8(NN2 $"5651DBCMFSFRVJSFE /FP4UZMF'BDFQMBUFJO8 YJO) YJO% <NN8 YNN) YNN% > 4BUVSO4UZMF'BDFQMBUFJO8 YJO) YJO% <NN8 YNN) YNN% > 4UBJOMFTT'BDFQMBUFJO8 YJO) YJO% <NN8 YNN) YNN% > 8FJHIU P[H FYDMVEJOHDPWFS 0QFSBUJOH&OWJSPONFOU 5FNQ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET Functional Aesthetics t$ MFBOMJOFEMPXQSPýMFUPVDITDSFFODBOCFXBMM mounted without external fittings t% JTQMBZBOEDPOUSPMTDBOCFDPOýHVSFEXJUI TZNCPMTJNBHFTDMPDLTBOEUJNFBOEUFYUJO multiple languages t" SFBQMBOTBOEPUIFSTDFOFTDBOCFHSBQIJDBMMZ depicted Distributed Intelligence t$ PNQBUJCMFXJUIBMM$#VTEFWJDFT t& BTJMZDPOýHVSFECZVTJOHUIF$#VT1*$&% software program 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 97 33 Catalog Number Description Accessories 4-$$5-8& .BSL**X/FP4UZMF8IJUF$PWFS1MBUF 4-$$58#.BSL**UPVDITDSFFOXBMMCPY 4-$$5-(# .BSL**X/FP4UZMF#SVTIFE"MVNBOE4MBUF$PWFS1MBUF 4-$$534.BSL**NPOP34DBCMFNNUP%#GFNBMFDPOOFDUJPO 4-$$5-#, .BSL**X/FP4UZMF#MBDL$PWFS1MBUF 4-$$5-8& .BSL**X4BUVSO4UZMF8IJUF$PWFS1MBUF 4-$$5-$. .BSL**X4BUVSO4UZMF$SFBN$PWFS1MBUF 4-$$5-#3 .BSL**X4BUVSO4UZMF.PDIB$PWFS1MBUF 4-$$5-#, .BSL**X4BUVSO4UZMF#MBDL$PWFS1MBUF 4-$$5-44 .BSL**X4UBJOMFTT4UFFM$PWFS1MBUF C-BUSTM LIGHTING CONTROL + TOUCH SCREENS Mark II Desktop Touch Screen 5IF.BSL**%FTLUPQ5PVDI4DSFFOJTBVOJýFEQBOFMGPSDPOUSPMMJOHMJHIUJOHTZTUFNTBOE accessories with the touch of a finger. %FTJHOFEXJUIWFSTBUJMJUZJONJOEUIFTFTMFFLUPVDITDSFFOTBSFFBTZUPJOTUBMM DVTUPNJ[FBOEVTF$PNQBDUZFUQPXFSGVMUIFUPVDITDSFFOIBTOVNFSPVT DPOýHVSBUJPOTBWBJMBCMFNBLJOHJUBOBUUSBDUJWFBMUFSOBUJWFUPNVMUJQMFTJOHMFPQFSBUJPO switches, ON/OFF toggles, dimmers, and timers which can clutter up even the nicest wall. 4DIOFJEFS&MFDUSJD$#VT5..BSL**%FTLUPQ5PVDI4DSFFOTBSFBWBJMBCMFJOCPUICMBDL and white. .BSL**%FTLUPQ5PVDI4DSFFO Technical Information Product Features Screen "$JOQVUJNQFEBODF ,PINT!L)[ %JTQMBZUZQF JODINN BDUJWFCMBDLBOEXIJUF-$%M 3FTPMVUJPO YQJYFMT 7JFXJOH"SFB -FGUSJHIUñVQñEPXOñ -VNJOBODF DENõ #BDLMJHIUUZQF 8IJUF-&% 5PVDITVSGBDFEVSBCJMJUZ 1 million presses (typical) .BYJNVNOVNCFS of controlled loads HSPVQBEESFTTFTPOFBDI of the 10 applications Programming port USB type 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% t. VMUJQMFDPOUSPMTDSFFOTDBOJODMVEFNVMUJ point switching and dimming, master ON/OFF switching, schedules, and scenes from a menu driven interface t" TUSPOPNJDBMDMPDLXJUIGVMMTDIFEVMJOHBOE holidays t PDBUPSPQUJPOUPIFMQVTFSTýOEUIFTDSFFOJO dim light t# VJMUJOJOGSBSFESFDFJWFSXSFNPUFDPOUSPM t6 4#QSPHSBNNJOHQPSUBDDFTTJCMFGSPNUIFGSPOU of the unit Functional Aesthetics t% JTQMBZBOEDPOUSPMTDBOCFDPOýHVSFEXJUI TZNCPMTJNBHFTDMPDLTBOEUJNFBOEUFYUJO multiple languages t" SFBQMBOTBOEPUIFSTDFOFTDBOCFHSBQIJDBMMZ depicted *For Diagram see technical section page 97 Distributed Intelligence t$ PNQBUJCMFXJUIBMM$#VTEFWJDFT t& BTJMZDPOýHVSFECZVTJOHUIF$#VT1*$&% software program Catalog Number Description 4-$$5%#, .BSL**%FTLUPQ5PVDI4DSFFOJO#MBDL 4-$$5%8& .BSL**%FTLUPQ5PVDI4DSFFOJO8IJUF 34 C-BUSTM LIGHTING CONTROL + TOUCH SCREENS Color Touch Screen 5IF$#VT5.$PMPS5PVDI4DSFFOJTBVOJýFEQBOFMGPSDPOUSPMMJOHMJHIUJOHTZTUFNTBOE accessories with the touch of a finger. 5IFUPVDITDSFFOhTTPQIJTUJDBUFEBQQFBSBODFSFþFDUTUIFVOEFSMZJOHDSBGUTNBOTIJQPGJUT EFTJHO"NPOHJUTNBOZDBQBCJMJUJFTUIJTQPXFSGVM1$CBTFETZTUFNTVQQPSUTHSBQIJDBM EFQJDUJPOPGBSFBQMBOTNPOJUPSJOHPGWBSJPVT$#VTEFWJDFTTDIFEVMJOHPGMJHIUJOHBOE other loads, finger-tip control of preset scenes, and operation from the touch screen or by remote controller. Technical Information Screen 5ZQF -$%BDUJWFNBUSJY 4J[F JOEJBHPOBM 3FTPMVUJPO 7("YQJYFMT 1JYFM1JUDI JO) YJO7 <NN) YNN7 > 7JFXJOH"SFB JO) YJO7 <NN) YNN7 > 5PVDI0WFSMBZ5ZQF $PMPS5PVDI4DSFFO Product Features 3FTJTUJWFNFNCSBOF 7JFXJOH"OHMF 5ZQJDBMIPSJ[POUBM¡MFGUBOESJHIU5ZQJDBMWFSUJDBM¡VQ¡EPXO -VNJOBODF DEN #BDLMJHIU $PMEDBUIPEFXJUIMJHIUTFOTPSGPSBVUPNBUJDCBDLMJHIUMFWFMDPOUSPM .FNPSZ .#DPNQBDU'MBTINFNPSZQSFQSPHSBNNFEXJUIQBOFMýSNXBSF #BDLVQ-JUIJVNCBUUFSZSFUBJOTDVSSFOUEBUFBOEUJNFGPSZFBST Components and Connectors 'SPOU &UIFSOFU3+UFSNJOBMIJEEFO 4QFBLFSIJEEFO *OGSBSFESFDFJWFS 3FBS $#VT3+UFSNJOBMT t&UIFSOFU3+UFSNJOBM $PNQPTJUFWJEFPPVUQVUWJB3$"UFSNJOBMPIN t34WJB%#UFSNJOBM 64#UZQF"UFSNJOBMT GPSGVUVSFTPGUXBSFTVQQPSU 3FNPUFJOGSBSFE*3 UFSNJOBMIBSEXJSFEWJBBNNNJOJKBDL &YUFSOBMTQFBLFSIFBEQIPOFUFSNJOBMNNNJOJKBDL 0WFSBMM%JNFOTJPOT JO8 YJO) YJO% <NN8 YNN) YNN% > 8FJHIU MCTH FYDMVEJOHDPWFSQMBUF 0QFSBUJOH&OWJSPONFOU 5FNQ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDFt&/*NNVOJUZUP&4% Required Accessories JO- YJO8 YJO) %JNFOTJPOT NN- YNN8 YNN) "EBQUPS#PY JO- YJO8 YJO) %JNFOTJPOT Functional Aesthetics t5PVDITFOTJUJWFJODIY DPMPS-$% panel t JHIUTFOTPSGPSBVUPNBUJDCBDLMJHIUDPOUSPM t'MVTIXBMMNPVOUEFTJHO t$PWFSQMBUFTBWBJMBCMFJO/FP5. and Saturn5. styles t'JWFDPMPSTDIFNFTBWBJMBCMFDPNQMFNFOUJOHBOZ EÏDPS Distributed Intelligence t$ PNQBUJCMFXJUIBMM$#VTDPNQPOFOUTJODMVEJOH LFZQBETTFOTPSTBOEEJNNFST t& BTJMZDPOýHVSFECZVTJOHUIF$#VT1*$&% Software Power Supply (Sold Separately) 1PXFS4VQQMZ t" CJMJUZUPDPOýHVSFDPOUSPMTJODMVEJOHTDFOFT schedules, state changes and graphic animation t" CJMJUZUPDVTUPNJ[FCVUUPOTTMJEFSTQIPUPTBOE drawings t" VEJPUPPMTTVQQPSUVTFPGDVTUPN8"7ýMFTGPS BVEJCMFGFFECBDLBOEWPJDFQSPNQUT t*OUFSOBMBNQMJýFETQFBLFSIBTWPMVNFDPOUSPMBOE FYUFSOBMTQFBLFSUFSNJOBM t# VJMUJO3+&UIFSOFUBOE$#VTOFUXPSL34 BOE64#UFSNJOBMT t*OGSBSFESFDFJWFSGPSSFNPUFDPOUSPMBOEJOGSBSFE input for accessories t$ POUSPMTDBOCFQBTTXPSEQSPUFDUFEBUNVMUJQMF levels t" TUSPOPNJDBMBOESFBMUJNFDMPDLT NN- YNN8 YNN) 8FJHIU MCLH 4UBOEBSET 6--JTUFE*OGPSNBUJPO5FDIOPMPHZ&RVJQNFOU4BGFUZ (FOFSBM3FRVJSFNFOUTt$4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDFt&/*NNVOJUZUP&4% 0VUQVU$BCMF GUN %$1MVH QJO%*/NBMF *For Diagram see technical section page 97 0SEFSOVNCFSTGPSUIF/FPBOE4BUVSOTUZMFUPVDITDSFFOTJODMVEFUIFTUPDLOVNCFSBOEUIFDPEFGPSUIFDPWFSDPMPS4BUVSO $PMPST#MBDL#, .PDIB#3 8IJUF8& BOE$SFBN$. /FP$PMPST#SVTIFE"MVNJOVNBOE4MBUF(# 8IJUF8& BOE #MBDL#, 'PSFYBNQMF4-$$5$8& SFQSFTFOUTB/FP4UZMF5PVDI4DSFFOJOXIJUF Catalog Number 35 Description 5. Power supply for color touch screen (sold separately) Accessories Description 4-$$5$ /FP 4UZMF5PVDI4DSFFO 4-$$5$ 4BUVSO4UZMF5PVDI4DSFFO 4-$$5$8# 4-$$5$/" $PMPS5PVDI4DSFFO8BMM/BJM#SBDLFU 4-$$5$3. $PMPS5PVDI4DSFFO8BMM1MBTUFS#PBSE#SBDLFU * Note: Required for every color touch screen installation. ** Note: Color touch screen must be mounted with one of these options 4-$$5$14$PMPS5PVDI4DSFFO1PXFS4VQQMZ $PMPS5PVDI4DSFFO8BMM#PY C-BUSTM LIGHTING CONTROL + SYSTEM UNITS C-BusTM Ethernet Network Interface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echnical Information &UIFSOFU/FUXPSL*OUFSGBDF $#VT7PMUBHF3FRVJSFNFOUT o7ED 4VQQMZ$VSSFOU 7"$PS%$!N" $#VT*OQVU7PMUBHF %PFTOPUESBXDVSSFOUGSPN UIF$#VT/FUXPSL UP7%$ &YUFSOBM1PXFS4VQQMZQSPWJEFE 7ED!N" &MFDUSJDBM*TPMBUJPO 4UBUVT*OEJDBUPST Product Features t1SPHSBNNJOH$#VT6OJUT t*TTVJOHDPNNBOETUPB$#VT/FUXPSLJODMVEJOH scheduled activities t.POJUPSJOHBOE%BUB-PHHJOHPGBDUJWJUJFTPOB $#VT/FUXPSL t4PGUXBSFTFMFDUBCMF$#VT4ZTUFN$MPDL 73.4DPOUJOVPVT$#VT34 &UIFSOFU-&%$PNNT-&% $#VT4ZTUFN$MPDL Software selectable $#VT/FUXPSL#VSEFO Software selectable &UIFSOFU$POOFDUJPO Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFECZVTJOHUIF$#VT5PPMLJU software 3+TPDLFUGPSDPOOFDUJPOUP&UIFSOFU %JNFOTJPOT JO) YJO8 YJO% <NN) YNN8 YNN% > 8FJHIU P[H 0QFSBUJOH 5FNQ¡'UP¡'¡$UP¡$ &OWJSPONFOU 3)OPODPOEFOTJOH 4UPSBHF&OWJSPONFOU 5FNQ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% Standards *For Diagram see technical section page 98 Catalog Number Description 4-$$/ Ethernet /FUXPSL*OUFSGBDF 36 C-BUSTM LIGHTING CONTROL + SYSTEM UNITS C-BusTM PC Interface 5IF$#VT5.1$*OUFSGBDF1$* FYQBOETPQUJPOTGPSDPOýHVSJOHDPOUSPMMJOHBOE NPOJUPSJOH$#VTOFUXPSLTCZQSPWJEJOHBOJOUFSGBDFCFUXFFOUIFOFUXPSLBOEB QFSTPOBMDPNQVUFS1$ PSPUIFSFYUFSOBMEFWJDF 5IF$#VT1$*NPEVMFFBTJMZNPVOUTUPB%*/SBJMBOEDPOOFDUTUPFYUFSOBMEFWJDFT UISPVHIJUTCVJMUJODPOOFDUPSQPSUT1PXFSUPUIFVOJUJTQSPWJEFEUISPVHIUIF$#VT OFUXPSL 1$*OUFSGBDF Technical Information 7PMUBHF 3FRVJSFNFOUT Product Features o7ED!N"SFRVJSFEGPSOPSNBMPQFSBUJPO ESBXOGSPNUIF$#VTOFUXPSL 73.4DPOUJOVPVT$#VT34 Electrical Isolation 4UBUVT 6OJU$PNNT6OJUQPXFSBOEEBUBUSBOTNJTTJPO *OEJDBUPST $#VT1PXFSMFWFMTBOEQSFTFODFPG$#VTDMPDL QJO34%UZQFTFSJBMDPOOFDUPS Serial 1PSU 343+DPOOFDUPST $BCMF GUN XJUI%#DPOOFDUPST $#VT$POOFDUJPO 3+TPDLFUTGPSDPOOFDUJPOUPB$#VTOFUXPSL %JNFOTJPOT JO) YJO8 YJO% <NN) YNN8 YNN% > .PVOUJOH %*/SBJM.XJEF 4FSJBM5FSNJOBUJPO 4UPSBHF&OWJSPONFOU 5FNQ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 5FNQ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% Standards *For Diagram see technical section page 98 Catalog Number 4-$1$ 37 t6OJU$PNNT-&%TIPXTUIFTUBUVTPGUIF VOJUTQPXFSBOEPGBOZEBUBUSBOTNJTTJPOT t$#VT-&%TIPXTUIFTUBUVTPGUIFOFUXPSL BUUIFVOJUJODMVEJOHUIFMFWFMPGOFUXPSL QPXFSBOEUIFQSFTFODFPGUIF$#VTDMPDL t4ZTUFNOFUXPSLDMPDLGPSTZODISPOJ[JOH communications data t5ISFF34TFSJBMDPOOFDUPSTGPSDPOOFDUJOHUPB1$PSUPFYUFSOBMEFWJDFT QJO%UZQFTFSJBMDPOOFDUPSGFNBMF BOE QJO3+DPOOFDUPST t5XP$#VTOFUXPSLDPOOFDUPSQPSUT3+ TPDLFUT t%BUBDBCMFGPSDPOOFDUJOH1$*BOEQFSTPOBM DPNQVUFSJODMVEJOH%#DPOOFDUPST Description 1$*OUFSGBDF Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT C-BUSTM LIGHTING CONTROL + SYSTEM UNITS C-BusTM PC Interface USB 5IF$#VT5.1$*OUFSGBDF1$* FYQBOETPQUJPOTGPSDPOýHVSJOHDPOUSPMMJOHBOE NPOJUPSJOH$#VTOFUXPSLTCZQSPWJEJOHBOJOUFSGBDFCFUXFFOUIFOFUXPSLBOEB QFSTPOBMDPNQVUFS1$ PSPUIFSFYUFSOBMEFWJDF 5IF$#VT1$*NPEVMFFBTJMZNPVOUTUPB%*/SBJMBOEDPOOFDUTUPFYUFSOBMEFWJDFT UISPVHIJUTCVJMUJODPOOFDUPSQPSUT1PXFSUPUIFVOJUJTQSPWJEFEUISPVHIUIF$#VT OFUXPSL 1$*OUFSGBDF64# Technical Information Product Features $CVTJOQVUWPMUBHF 7E $VSSFOUESBXO N" &MFDUSJDBMJTPMBUJPOSBUJOH 7SNTDPOUJOVPVT$#VT34 $PNNVOJDBUJPOT 64#5ZQF"UP# 0QFSBUJOHUFNQFSBUVSF ¡'¡$ 0QFSBUJOHIVNJEJUZSBOHF 3)OPODPOEFOTJOH 5FSNJOBMT $#VT3+DPOOFDUPST 64#UP1$ %JNFOTJPOT JO- YJO8 YJO% <NN- YNN8 YNN% > 8FJHIU MCTH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% t6OJU$PNNT-&%TIPXTUIFTUBUVTPGUIF VOJUTQPXFSBOEPGBOZEBUBUSBOTNJTTJPOT t$#VT-&%TIPXTUIFTUBUVTPGUIFOFUXPSL BUUIFVOJUJODMVEJOHUIFMFWFMPGOFUXPSL QPXFSBOEUIFQSFTFODFPGUIF$#VTDMPDL t4ZTUFNOFUXPSLDMPDLGPSTZODISPOJ[JOH communications data t64##5ZQF $POOFDUPS t5XP$#VTOFUXPSLDPOOFDUPSQPSUT3+ TPDLFUT t5IF%BUBDBCMFGPSDPOOFDUJOH1$*BOE personal computer does not include %#DPOOFDUPST Distributed Intelligence t$PNQBUJCMFXJUIBMM$CVTEFWJDFT *For Diagram see technical section page 98 Catalog Number Description 4-$1$6 1$*OUFSGBDF64#.PEFM 38 C-BUSTM LIGHTING CONTROL + SYSTEM UNITS C-BusTM Network Bridge 5IF$#VT5./FUXPSL#SJEHFQSPWJEFTBDPNNVOJDBUJPODIBOOFMCFUXFFO$-Bus units POTFQBSBUFOFUXPSLTFYQBOEJOHUIFUPUBMOVNCFSPGVOJUTUIBUDBOCFDPOýHVSFE controlled, and monitored. /FUXPSL#SJEHF Technical Information 7PMUBHF 3FRVJSFNFOUT Product Features o7ED!N"SFRVJSFEGPSOPSNBMPQFSBUJPO ESBXOGSPNFBDIDPOOFDUFE$#VTOFUXPSL &MFDUSJDBM*TPMBUJPO L73.4GPSNJOCFUXFFOOFUXPSLT 4UBUVT /FUXPSL"/FUXPSL# *OEJDBUPST 1SPQBHBUJPO%FMBZ 1PXFS0/$PNNVOJDBUJPOTJOQSPHSFTT Power OFF - Not connected/insufficient power NTEFMBZGPSNFTTBHFUSBOTGFSCFUXFFOUXPBEKBDFOU$#VT/FUXPSLT *OUFSDPOOFDU *OQBSBMMFMOFUXPSLTOFUXPSLCSJEHFT $BQBDJUZ *OTFSJFTOFUXPSLTOFUXPSLCSJEHFT $#VT4ZTUFN$MPDL 4PGUXBSFTFMFDUBCMF $#VT/FUXPSL#VSEFO 4PGUXBSFTFMFDUBCMF $#VT$POOFDUJPO %JNFOTJPOT QBJSPG3+TPDLFUTGPSDPOOFDUJPO UP$#VTOFUXPSLT JO) YJO8 YJO% <NN) YNN8 YNN% > 8FJHIU 0QFSBUJOH&OWJSPONFOU P[H 5FNQ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 99 Catalog Number 4-$/# 39 Description /FUXPSL#SJEHF t*ODSFBTFTUSBOTNJTTJPOEJTUBODFTCZBDUJOHBT a repeater station for data transmission t&YQBOETUIFUPUBMOVNCFSPG$#VT devices that can operate on the system by isolating EFWJDFTUPJOEJWJEVBMOFUXPSLT<*OQBSBMMFM OFUXPSLTOFUXPSLCSJEHFT *OTFSJFT OFUXPSLTOFUXPSLCSJEHFT > t*OEJDBUFTFBDIOFUXPSLTTUBUVTMFWFM t4UPSFTPQFSBUJOHTUBUVTJOOPOWPMBUJMFNFNPSZ for recovery from a power outage t6TFTCVJMUJODPOOFDUPSTUPDPOOFDUUPB $#VT OFUXPSL Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFECZVTJOHUIF$#VT5PPM,JU software C-BUSTM LIGHTING CONTROL + SYSTEM UNITS C-BusTM Power Supply 5IF$#VT5.1PXFS4VQQMZJTTQFDJýDBMMZEFTJHOFEUPPQFSBUFXJUIUIF$#VTOFUXPSL BTBQPXFSTPVSDFGPSQBTTJWF$#VTEFWJDFT 5IFQPXFSTVQQMZNPVOUTUPB%*/SBJMBOEDPOOFDUTUPUIF$#VTOFUXPSLUISPVHI CVJMUJO3+DPOOFDUPST 5IFTFEFWJDFTBSF6-MJTUFEBT$MBTTQPXFSTVQQMJFTBOEBSFTVJUBCMFGPSQBSBMMFM PQFSBUJPO6QUPýWFQPXFSTVQQMJFTDBOCFDPOOFDUFEUPBTJOHMF$#VTOFUXPSL Power Supply Technical Information /PNJOBM-JOF7PMUBHF Product Features 0QFSBUFTBUPS7BDXJUIBGSFRVFODZSBOHFGSPNo)[ &MFDUSJDBM*TPMBUJPO L73.4GSPN$#VTUPUIFMJOF $VSSFOU0VUQVU N"UPUIF$#VTOFUXPSL 4UBUVT*OEJDBUPST 6OJU6OJUQPXFS $#VT/FUXPSLWPMUBHFMFWFMBOE QSFTFODFPGTZTUFNDMPDL 1PXFS4VQQMJFTQFS/FUXPSL 6QUPýWFQPXFSTVQQMJFTPOBTJOHMF$#VTOFUXPSL $#VT$POOFDUJPO 3+TPDLFUTGPSDPOOFDUJPOUPUIF$#VTOFUXPSL $BCMF JONN QBUDIMFBEJODMVEFE %JNFOTJPOT JO) YJO8 YJO% <NN) YNN8 YNN% > .PVOUJOH %*/SBJM.XJEF 8FJHIU P[H 0QFSBUJOH &OWJSPONFOU 5FNQ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UPSBHF &OWJSPONFOU 5FNQ¡'UP¡'o¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET t"WBJMBCMFJOBOE7BDNPEFMT t3FHVMBUJOHQPXFSTVQQMZDPNQFOTBUFTGPS line voltage and frequency variations, so there is constant output t4PVSDFTVQUPN"UPUIF$#VTOFUXPSL t6-MJTUFEUPPQFSBUFJOQBSBMMFMXJUIPUIFS $#VTQPXFSTVQQMJFTVQUPýWFPOBTJOHMF $#VTOFUXPSL t*ODPSQPSBUFTTIPSUDJSDVJUBOESFWFSTFQPMBSJUZ protection t*OEJDBUFTUIFMJOFWPMUBHFTUBUVTXJUIB6OJU -&% t*OEJDBUFTUIFOFUXPSLTUBUVTJODMVEJOHUIF OFUXPSLQPXFSBOEUIFQSFTFODFPGUIF $#VTDMPDLXJUIB$#VT-&% t4UBOEBSECVJMUJO$#VTOFUXPSLDPOOFDUPST 3+ Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 99 Catalog Number Description 4-$514 7BD1PXFS4VQQMZ 4-$)14 7BD1PXFS4VQQMZ 40 C-BUSTM LIGHTING CONTROL + SYSTEM UNITS C-BusTM Pascal Automation Controller 5IF$#VT5.1BTDBM"VUPNBUJPO$POUSPMMFS1"$ QSPWJEFTFYUFOEFEDPOEJUJPOBM BOESFBMUJNFFWFOUQSPHSBNNJOHUP$#VTTZTUFNT5IF1"$TVQQPSUTBGVMMSBOHF PGQSPHSBNNJOHDPNNBOETJODMVEJOHDPOEJUJPOBMMPHJDþPXDPOUSPMWBSJBCMFTBOE scheduling. Systems integrators will appreciate the built-in scheduling tools, scene tools, and wizards for creating basic logic programs. Full programming capabilities can be achieved VUJMJ[JOHUIFGSFFGPSNTDSJQUFEJUPSCBTFEPGGUIF1"4$"-QSPHSBNNJOHMBOHVBHF 5IF1"$EJSFDUMZDPOOFDUTUPBXJSFE$#VTTZTUFN1SPHSBNTBSFEPXOMPBEFEGSPNB personal computer through a USB connection. 1BTDBM"VUPNBUJPO$POUSPMMFS Technical Information Product Features $#VT5.4VQQMZ7PMUBHF 7ED!N"%SBXOGSPNUIF$#VTOFUXPSL 344VQQMZ7PMUBHF 7BD!N"QPXFSTPVSDFOPUQSPWJEFE #BUUFSZ#BDLVQ4VQQMZ7PMUBHF 7ED!N"QPXFSTPVSDFOPUQSPWJEFE $POOFDUJPOT $#VT3+TPDLFUTJOQBSBMMFM 343+TPDLFUT 64#UZQF#TPDLFU TDSFXUFSNJOBMTGPS7EDCBUUFSZBOE7BDQPXFS $#VT4ZTUFN$MPDL 4PGUXBSFTFMFDUBCMF /FUXPSL#VSEFO 4PGUXBSFTFMFDUBCMF 4UBUVT*OEJDBUPST 6OJU$PNNT$#VT4UBUVTBOE6TFS %JNFOTJPOT YYJODIFTYYNN 8FJHIU P[H .PVOUJOH %*/.XJEF 0QFSBUJOH&OWJSPONFOU ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 100 41 Catalog Number Description 4-$1"$" 1BTDBM"VUPNBUJPO$POUSPMMFS t$POEJUJPOBMBOESFBMUJNFFWFOUTQSPHSBNNJOH GPS$#VT t$POOFDUTEJSFDUMZUP$#VTOFUXPSL t1PXFSFEGSPNUIF$#VTOFUXPSL t64#QPSUGPSDPOOFDUJPOUPQFSTPOBMDPNQVUFS t 34QPSUTGPSUIJSEQBSUZEFWJDFDPOUSPM t3FBMUJNFBTUSPOPNJDBMBOE$#VTTZTUFN DMPDLJODMVEFEXJUIIPVSJOUFSOBMDBQBDJUPS CBDLVQBOEFYUFSOBM7EDCBUUFSZUFSNJOBMT Programming capabilities including: t$POEJUJPOBMMPHJDJGUIFOBOEPSOPUFUD t'MPX$POUSPMGPSSFQFBUXIJMF t7BSJBCMFTJOUFHFSSFBM#PPMFBODIBSBDUFS string) t$POUSPMBOENPOJUPSJOHPGHSPVQBEESFTTFT t$POUSPMBOENPOJUPSJOHPGTDFOFT Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFEXJUIUIF$#VT1*$&% Software C-BUSTM LIGHTING CONTROL + SYSTEM UNITS C-BusTM Telephone Interface Unit 5IF$#VT5FMFQIPOF*OUFSGBDFPGGFSTBEJBMJOBOEEJBMPVUGVODUJPOBMJUZQFSNJUUJOH DPOUSPMBOETUBUVTNPOJUPSJOHGPSB$#VTTZTUFN*UBMTPJODMVEFTBOBVEJPPVUQVUTP UIBU$#VTFWFOUTDBOCFBVEJCMZBOOPVODFE 5IF5FMFQIPOF*OUFSGBDFJTQSPHSBNNFEVTJOHBDPOOFDUJPOUPB1$SVOOJOHTQFDJBM DPOýHVSBUJPOTPGUXBSF5IFJOUFSGBDFDBOBMTPBDUBTB$#VT1$*OUFSGBDF*OUIJTXBZ $#VTDBOCFQSPHSBNNFEBOEDPOýHVSFEFJUIFSMPDBMMZPSGSPNBSFNPUFTJUFVTJOHB data modem. 5IF5FMFQIPOF*OUFSGBDFJTTVJUBCMFGPSDPOOFDUJPOUPUIFUFMFQIPOFOFUXPSLVTJOHB 3+9DPOOFDUJPOJOQBSBMMFMPSCZJOTFSUJPOJOUPBMPDBMDJSDVJU 5FMFQIPOF*OUFSGBDF6OJU Technical Information Product Features $#VT4VQQMZ7PMUBHF 7ED!N"/PNJOBM %$1MVH1BDL 7ED!N"NNQMVHXJUI$FOUFSQJO7& "VEJP0VUQVU -JOFPVUQVU7QQOPNJOBM JOUP,0INT $POUSPM'VODUJPOT %JBMJOBOE%JBMPVUGVODUJPOBMJUZDPOUSPMBOETUBUVTNPOJUPSJOHGPSB $#VTTZTUFN"VEJPPVUQVU4UBOEBSE$#VT1$*BMMPXJOHSFNPUFEJBMJO BOEPQFSBUJPOBTB1$*XJUINPEFNDPOOFDUJPOGPSSFNPUF operation of installation software 4UBUVT*OEJDBUPST (SFFO-&%1PXFS 0SBOHF-&%34$PNNT-JOF(SBC 6OJU$PNNTBOE$#VT 4UBSU6Q5JNF t"VEJP065 t-PDBMPSSFNPUFTJUFBDDFTTUP$#VTTZTUFN t7EDQPXFSQBDL t34DPOOFDUJPO t3+QBUDIMFBE t2 RJ12 patch leads tSoftware available via website download TFDPOETOPNJOBMBGUFS1PXFS6Q 4UPSBHF5FNQFSBUVSF ¡UP¡'¡UP¡$ 0QFSBUJOH5FNQFSBUVSF3BOHF ¡UP¡'¡UP¡$ 0QFSBUJOH)VNJEJUZ3BOHF ¡UP3)OPODPOEFOTJOH $#VT*OQVU5FSNJOBMT 3+TPDLFUT $PMPS 8IJUFXJUI#MBDLMFUUFSJOHBOENBSLJOHT %JNFOTJPOT YYJOYYNN 8FJHIU MCTH .PVOUJOH$FOUFST JONN 4UBOEBSET 6-&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM '$$1BSU$POOFDUJPOTPG5FSNJOBM&RVJQNFOU UPUIF5FMFQIPOF/FUXPSL *For Diagram see technical section page 100 Catalog Number 4-$564 Description 5FMFQIPOF*OUFSGBDF6OJU 42 C-BUSTM LIGHTING CONTROL + INPUT UNITS C-BusTM General Input Unit 5IF$#VT5.'PVS$IBOOFM(FOFSBM*OQVU6OJUTBSF%*/SBJMNPVOUFEEFWJDFTUIBU NFBTVSF55-EJHJUBMBOESFBMXPSMEBOBMPHRVBOUJUJFTBOEHFOFSBUFNFTTBHFTBCPVUUIF NFBTVSFNFOUTUPUIF$#VTOFUXPSL#ZBDUJOHBTBOJOUFSGBDFXJUIWBSJPVTFYUFSOBM TFOTPSTUIFHFOFSBMJOQVUVOJUFOBCMFTJOUFHSBUJPOPGUIF$#VTOFUXPSLXJUIBWBSJFUZPG TZTUFNUZQFTTVDIBTUIPTFGPS)7"$BOEGPSQPXFSNPOJUPSJOH $POýHVSBUJPOPQUJPOTJODMVEFTFMFDUBCMFJOQVUUZQFTFJHIUBEKVTUBCMFEFDJTJPOUISFTIPMET per channel, definable actions, selectable filtering, broadcast rates, and a separate hysteresis value per channel. (FOFSBM*OQVU6OJU Technical Information /PNJOBM7PMUBHF3FRVJSFNFOUT Product Features WPMUT!N"GSPNUIF$#VTOFUXPSL /PNJOBM 7BD /PNJOBM4VQQMZ7PMUBHF 7"$%$)[ provided by an external power supply (included) "$*OQVU*NQFEBODF L0IN!L)[ &YUFSOBM1PXFS4VQQMZ 7BD!N" &MFDUSJDBM*TPMBUJPO 73.4QFSJOQVU /PNJOBM7ED0VUQVU7PMUBHF 7ED!N"(FOFSBM*OQVU %JHJUBM4FOTPS*OQVU 55-7GSPNFYUFSOBMTPVSDF "OBMPH4FOTPS*OQVUT 7PMUBHF3BOHFT *OQVU$VSSFOU3BOHFT 3FTJTUBODF3BOHFT oooo7ED oN"%$oN"%$ oPINoPINoPINoPIN .BYJNVN*OQVU7PMUBHFT 7UP7ED *OQVU7PMUBHF3BOHF*NQFEBODF "UMFBTUL0IN 3FTJTUBODF3BOHF*OKFDUJPO$VSSFOU ç" #BTJD"DDVSBDZBGUFS$BMJCSBUJPO PGGVMMTDBMF $VSSFOU4FOTF*NQFEBODF PIN .BYJNVN*OQVU'SFRVFODZ )[ #SPBEDBTU3BUFT oTFD /VNCFSPG6OJUTQFS/FUXPSL $#VT$POOFDUJPOT 3+DPOOFDUPST$"5651DBCMFSFRVJSFE $BCMF JONN QBUDIMFBEJODMVEFE 5FSNJOBMT "DDPNNPEBUFo"8(DBCMFYNN2PSYNN2) 4UBUVT*OEJDBUPST 6OJU$PNNT6OJUQPXFSBOEEBUBUSBOTNJTTJPO $#VT1PXFSMFWFMTBOEQSFTFODFPG$#VTDMPDL %JNFOTJPOT JO- YJO8 YJO) <NN- YNN8 YNN) > 8FJHIU P[H .PVOUJOH %*/SBJM.XJEF 0QFSBUJOH&OWJSPONFOU ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM &/*NNVOJUZUP&4% 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU *For Diagram see technical section page 100 Catalog Number 4-$&5(* 43 t.FBTVSFT55-EJHJUBMRVBOUJUJFTJODMVEJOH voltage, current, or resistance from external sensors such as light level, pressure, and temperature t'PVSDIBOOFMTPGJOQVUFBDIXJUIBO adjustable hysteresis value, eight decision thresholds, and a software-selectable input WBMVFUSBOTGPSNBUJPOJOUIFGPSNZBYC t*OQVUDIBOOFMTBSFDPNQBUJCMFXJUIBSBOHFPG third-party sensors t-PPLVQUBCMFXJUIJOUFSQPMBUJPO t$BQBCMFPGUISFTIPMETXJUDIJOHPS CSPBEDBTUJOHWBMVFTPOUPUIFOFUXPSL t$POUSPMGVODUJPOTJODMVEFMPBETXJUDIJOH dimming, trigger applications, enable control applications, and measurement applications t.FBTVSFTJOQVUTJHOBMTVQUP)[BOEIBT an adjustable input-signal filter to reduce susceptibility to impulse and noise t4VQQMJFTN"UPFYUFSOBMTFOTPST t-&%TJOEJDBUFUIFTUBUVTPGUIFOFUXPSL BUUIFVOJUBOEUIFVOJUTQPXFSBOEEBUB transmissions t4PGUXBSFTFMFDUBCMFOFUXPSLCVSEFOBOE $#VTTZTUFNDMPDL t4UBOEBSECVJMUJO$#VTOFUXPSLDPOOFDUPST 3+ tNon-volatile memory stores operating status for recovery from a power outage t*ODMVEFT77"$QPXFSQBDL Description $IBOOFM(FOFSBM*OQVU6OJU Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFEXJUIUIF$#VT5PPMLJU Software C-BUSTM LIGHTING CONTROL + INPUT UNITS C-BusTM Bus Coupler 5IF$#VT5.#VT$PVQMFSTBSFOPOJTPMBUFEJOQVUEFWJDFTUIBUQSPWJEFBOJOUFSGBDF CFUXFFOESZDPOUBDUNFDIBOJDBMTXJUDIFTBOEB$#VTOFUXPSL5IFCVTDPVQMFS JODSFBTFTUIFWFSTBUJMJUZPGUIF$#VTOFUXPSLCZGBDJMJUBUJOHSFNPUFBDDFTTXJUIBOZESZ contact switch mechanism offered by Schneider Electric and other manufacturers. "TZTUFNTþFYJCJMJUZDBOCFGVSUIFSFOIBODFECZVTJOHUIFCVTDPVQMFSXJUIWBSJPVTPUIFS switch types, including reed, pressure, or micro switches. "WBJMBCMFJOUXPBOEGPVSDIBOOFMNPEFMTUIFCVTDPVQMFSJTTNBMMFOPVHIUPCFVTFEJO SFTUSJDUFETQBDFT$POýHVSBUJPOPQUJPOTJODMVEFTUBOEBSEDPOUSPMGVODUJPOTTVDIBT0/ OFF, toggle, dimmers, and timers. 'PVS$IBOOFM#VT$PVQMFS Technical Information /PNJOBM7PMUBHF Product Features 7ED!N"ESBXOGSPNUIF 3FRVJSFNFOUT $#VTOFUXPSL Electrical Isolation None 7PMUBHF"DSPTT*OQVU &YUFSOBM4XJUDI0QFOT7ED &YUFSOBM4XJUDI$MPTFT7ED $VSSFOUo4XJUDI$MPTFE -FTTUIBOç" %JTUBODF#FUXFFO $IBOOFM$PVQMFS6QUPGUN FBDI 4XJUDIBOE#VT$PVQMFS $IBOOFM$PVQMFS6QUPGUN FBDI -&%%SJWF0VUQVU $IBOOFM$PVQMFSPOMZN"!7 .BYJNVN*OQVU7PMUBHFT UP7ED /VNCFSPG6OJUT 6TFUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZUPEFUFSNJOF QFS/FUXPSL UIFUPUBMOFUXPSLDVSSFOUMPBE $#VT$POOFDUJPOT 5XPXBZSFNPWBCMFTDSFXUZQFUFSNJOBMTBDDPNNPEBUJOH o"8(DBCMFoNN2) $IBOOFM*OQVU 4QSJOHMPBEFEUFSNJOBMCMPDLBDDPNNPEBUJOH $POOFDUJPOT o"8(DBCMFoNN2) 4UBUVT*OEJDBUPST $IBOOFMPS 5JNFST %JNFOTJPOT t1SPWJEFTUXPPSGPVSOPOJTPMBUFEJOQVUTGPS external voltage-free mechanical switches. 5XPDIBOOFMVOJUTGFBUVSFJOEFQFOEFOUSFNPUF -&%PVUQVUT t$POUSPMPQUJPOTJODMVEF0/0''UPHHMF dimmer, or timer t0SBOHF-&%GPSFBDIDIBOOFMUPJOEJDBUF operational status t#VJMUJOTDFOFTUPSBHFGPSVQUPDPOUSPMMBCMF addresses with remote scene triggering capabilities t5XPXBZSFNPWBCMFUFSNJOBMCMPDLGPSUIF $#VTDPOOFDUJPO t5FSNJOBMCMPDLBMMPXTDPOOFDUJPOPGVQUPGPVS external switches (four-channel coupler) or two FYUFSOBMTXJUDIFTBOEUXPFYUFSOBM-&%TUXP channel coupler) t4NBMMTJ[FGPSBEBQUBUJPOUPSFTUSJDUFETQBDFT t/POWPMBUJMFNFNPSZTUPSFTPQFSBUJOHTUBUVT for recovery from a power outage t3FDFJWFTEBUBBOEQPXFSPWFSBOFUXPSLTP JUEPFTOPUSFRVJSFQPXFSQBDLTPSMJOFWPMUBHF connections TFDoISTFDJOUFSWBMT JO- YJO8 YJO) <NN- YNN8 YNN) > 8FJHIU P[H 0QFSBUJOH&OWJSPONFOU ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFECZVTJOH-FBSO.PEFPSUIF $#VT5PPMLJU4PGUXBSF 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM &/*NNVOJUZUP&4% *For Diagram see technical section page 100 Catalog Number Description 4-$#$-&%- 5XP$IBOOFM#VT$PVQMFS 4-$#$- 'PVS$IBOOFM#VT$PVQMFS 44 C-BUSTM LIGHTING CONTROL + INPUT UNITS C-BusTM Four-Channel Auxiliary Input 5IF$#VT5.'PVS$IBOOFM"VYJMJBSZ*OQVUTBSFJTPMBUFEGPVSDIBOOFMJOQVUVOJUTUIBU QSPWJEFBOJOUFSGBDFCFUXFFOWPMUBHFGSFFNFDIBOJDBMTXJUDIFTBOEB$#VTOFUXPSL "OBVYJMJBSZVOJUJODSFBTFTUIFWFSTBUJMJUZPGUIF$#VTOFUXPSLCZGBDJMJUBUJOHSFNPUF access with any dry-contact switch mechanism offered by Schneider Electric or other manufacturers. %*/SBJMNPVOUFEGPSRVJDLJOTUBMMBUJPOUIFBVYJMJBSZVOJUDBOCFDPOýHVSFEXJUITUBOEBSE $#VTDPOUSPMGVODUJPOTTVDIBTSFNPUFTDFOFUSJHHFSJOH0/0''UPHHMFEJNNFSPS timer. 'PVS$IBOOFM "VYJMJBSZ*OQVU6OJU Product Features Technical Information /PNJOBM7PMUBHF3FRVJSFNFOUT7ED!N"ESBXOGSPNUIF$#VTOFUXPSL &MFDUSJDBM*TPMBUJPO $#VT3FNPUF*OQVU73.4 3FNPUF*OQVU73.4 7PMUBHF"DSPTT*OQVU &YUFSOBM4XJUDI0QFOT7ED&YUFSOBM4XJUDI$MPTFT7ED $VSSFOUo4XJUDI$MPTFE N" 4XJUDI3FTJTUBODF 6QUPPINJODMVEJOHDBCMFSFTJTUBODFPINTQFSLN SFTJTUBODFGPSDPQQFSXJSFDPBUFE%$DVSSFOUSFTJTUBODF /VNCFSPG6OJUT QFS/FUXPSL 6TFUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZ UPEFUFSNJOFUIFUPUBMOFUXPSLDVSSFOUMPBE $#VT$POOFDUJPOT 3+DPOOFDUPST$"5651DBCMFSFRVJSFE $BCMF JONN QBUDIMFBEJODMVEFE 5FSNJOBMT 4UBUVT*OEJDBUPST "DDPNNPEBUFPOFPSUXP"8(DBCMFT YNN PSYNN > $IBOOFM PSBOHF-&%TUPJOEJDBUFUIFMPBETUBUVTGPSFBDIDIBOOFM 5JNFST %JNFOTJPOT TFDoISTFDJOUFSWBMT JO- YJO8 YJO) <NN- YNN8 YNN) > 8FJHIU P[H .PVOUJOH %*/SBJM.XJEF 0QFSBUJOH&OWJSPONFOU ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 101 45 Catalog Number Description SLCLE5504AUX 4 Channel Auxiliary Input Unit t1SPWJEFTGPVSJTPMBUFEJOQVUTGPSFYUFSOBM voltage-free mechanical switches t$POUSPMPQUJPOTJODMVEFSFNPUFTDFOF triggering, ON/OFF, toggle, dimmer, or timer operations t0SBOHF-&%TJOEJDBUFPQFSBUJPOBMTUBUVTPOF for each channel t4UBOEBSECVJMUJO$#VTOFUXPSLDPOOFDUPST 3+ t/POWPMBUJMFNFNPSZTUPSFTPQFSBUJOHTUBUVT for recovery from a power outage Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFECZVTJOH-FBSO.PEFPSUIF $#VT5PPMLJU4PGUXBSF C-BUSTM LIGHTING CONTROL + SENSORS C-BusTM 90° Indoor PIR Occupancy Sensor 5IF$#VT5. Indoor PIR Occupancy Sensor provides reliable thermal-radiation-based DPOUSPMPGMJHIUJOHBOEPUIFS$#VTPVUQVUEFWJDFT Suitable for wall or ceiling mounting, this sensor offers a continuous detection field of TRVBSFGFFUBOEB¡ýFMEPGWJFX5IFFOUJSFEFUFDUJPOýFMEIBTVOJGPSNTFOTJUJWJUZ BOEOPEFBE[POFTNBLJOHJUBOJEFBMMJHIUJOHDPOUSPMTPMVUJPOGPSPGýDFTDPSSJEPSTBOE conference rooms. $POýHVSBUJPOPQUJPOTJODMVEFBOBEKVTUBCMFMJHIUMFWFMTFOTPSUIBUDBOCFTFUUP automatically turn off lights when ambient light levels are sufficient or turn on lights when ambient light levels are insufficient. Indoor PIR Occupancy Sensor Product Features Technical Information /PNJOBM7PMUBHF3FRVJSFNFOUT7ED!N"ESBXOGSPNUIF$#VTOFUXPSL 'JFMEPG7JFX ¡ 1*3%FUFDUJPO'JFME 5ZQJDBMMZTRGUTRN -JHIU-FWFMJOIJCJU5ISFTIPME GPPUDBOEMFMVY UPGVMMTVOMJHIU 5JNFS%FMBZ3BOHF TFDISTFDJOUFSWBM /VNCFSPG6OJUT QFS/FUXPSL 6TFUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZUP EFUFSNJOFUIFUPUBMOFUXPSLDVSSFOUMPBE $#VT$POOFDUJPO 4DSFXUZQFUFSNJOBMTJOQVUUFSNJOBMTBDDPNNPEBUF "8(DBCMFNN2) 4UBUVT*OEJDBUPST -&%DBOCFDPOýHVSFEUPUVSOPOXIFONPWFNFOUJTEFUFDUFE %JNFOTJPOT JO8 YJO) <NN8 YNN) > 8FJHIU P[H .PVOUJOH 4VSGBDF$FJMJOHPSXBMM )UGUN BCPWFþPPS 0QFSBUJOH&OWJSPONFOU *OEPPS¡'UP¡'¡$UP¡$ 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% t*OEPPSVTFXBMMPSDFJMJOHNPVOUFEVOJUXJUI B¡ýFMEPGWJFXBOEBEFUFDUJPOBSFBPG square feet t-&%DBOCFDPOýHVSFEUPJOEJDBUFNPUJPO detection t-JHIUMFWFMTFOTPSIBT4VOSJTF4VOTFUTFUUJOHT DMPDLPWFSSJEFTBOEBEKVTUBCMFTFOTJUJWJUZ ranging from 0.1 foot candle to full sunlight t"EWBODFEDJSDVJUSZUPIFMQQSFWFOUGBMTF triggering, including electrostatic and electromagnetic shields, dual element detectors, pyroelectric ceramic sensors, and an optical band pass filter t$POUSPMTVQUPGPVS$#VTHSPVQBEESFTTFT that can be individually scheduled t/POWPMBUJMFNFNPSZTUPSFTPQFSBUJOHTUBUVT for recovery from a power outage t3FDFJWFTEBUBBOEQPXFSPWFSBOFUXPSLTP UIFTFOTPSEPFTOPUSFRVJSFQPXFSQBDLTPS line voltage connections Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFECZVTJOH-FBSO.PEFPSUIF $#VT5PPMLJU4PGUXBSF *For Diagram see technical section page 101 Catalog Number Description 4-$- ¡*OEPPS1*30DDVQBODZ4FOTPS 46 C-BUSTM LIGHTING CONTROL + SENSORS C-BusTM 360° PIR Occupancy Sensor 5IF$#VT5.¡*OEPPS1*30DDVQBODZ4FOTPSDPNCJOFTBQBTTJWFJOGSBSFESFDFJWFS 1*3 GPSPDDVQBODZTFOTJOHBOEBMJHIUMFWFMTFOTPSJOUPBTNBMMIJHIMZWFSTBUJMFVOJU5IF NVMUJTFOTPSTJODIGBDFEJBNFUFSNBLFTJUVOPCUSVTJWFBOEJEFBMMZTVJUFEGPSþVTI mounting on the ceiling. 5IJTTFOTPSIBTBEFHSFFýFMEPGWJFXXJUIBOFGGFDUJWFDPWFSBHFQBUUFSOPGNPSF UIBOGFFUTPJUJTJEFBMMZTVJUFEGPSPGýDFTDPQJFSSPPNTDMPTFUTBOESFTUSPPNT .VMUJQMFTFOTPSTDBOCFDPOOFDUFEUPUIFTBNF$#VTOFUXPSLUPQSPWJEFMBSHFS coverage patterns. $POýHVSBUJPOPQUJPOTJODMVEFBEKVTUBCMFUJNFEFMBZTGPSBVUPNBUJDTIVUPGGGPMMPXJOHB preset time period without detected motion and an adjustable light-level sensor that can be set to automatically turn off lights when ambient light levels are sufficient or turn on lights when ambient light levels are insufficient. ¡1*30DDVQBODZ4FOTPS Technical Information Product Features /PNJOBM7PMUBHF3FRVJSFNFOUT7ED!N"ESBXOGSPNUIF$#VTOFUXPSL 'JFMEPG7JFX ¡ 1*33BUFE 5ZQJDBMMZTRGUTRN XIFOTFOTPSJT %FUFDUJPO'JFME NPVOUFEGUN BCPWFþPPS -JHIU-FWFMJOIJCJU5ISFTIPME GPPUDBOEMFMVY UPGVMMTVOMJHIU 5JNFS%FMBZ TFDUPIS /VNCFSPG6OJUT QFS/FUXPSL 6TFUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZUP EFUFSNJOFUIFUPUBMOFUXPSLDVSSFOUMPBE $#VT$POOFDUJPO 4UBUVT*OEJDBUPST 5XPSFNPWBCMFUFSNJOBMCMPDLTSFRVJSFT$"5EBUBDBCMF -&%DBOCFDPOýHVSFEUPUVSOPOXIFONPWFNFOUJTEFUFDUFE %JNFOTJPOT JO- YJO8 <NN- YNN8 > 8FJHIU P[H .PVOUJOH 4VSGBDF$FJMJOH )UGUN BCPWFþPPS .BY)UGUN BCPWFþPPS .JO$FJMJOH5IJDLOFTTJONN Operating Indoor only &OWJSPONFOU ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 101 47 Catalog Number Description 4-$- ¡1*30DDVQBODZ4FOTPS t¡EFUFDUJPOQBUUFSOJOEPPSVTF t&GGFDUJWFDPWFSBHFBSFBJTNPSFUIBOTRVBSF GFFUXIFOVOJUJTNPVOUFEGFFUBCPWFUIFþPPS t%VBMFMFNFOUEFUFDUPSTNJOJNJ[FGBMTFUSJHHFSJOH t-&%TJOEJDBUFNPWFNFOUEFUFDUJPO t$BODPOUSPMVQUPGPVSTDFOFTPSHSPVQ addresses that can be individually scheduled t"EKVTUBCMFMJHIUMFWFMTFOTPSXJUI4VOSJTF 4VOTFUBOEDMPDLPWFSSJEFT t"UUSBDUJWFMPXQSPýMFVOJUDBOCFþVTINPVOUFE on ceiling or suspended from wall tiles where it JTVOPCUSVTJWFXJUIBGBDFEJBNFUFSPGPOMZ inches t/POWPMBUJMFNFNPSZTUPSFTPQFSBUJOHTUBUVTGPS recovery from a power outage t3FDFJWFTEBUBBOEQPXFSPWFSBOFUXPSL /PQPXFSQBDLTPSMJOFWPMUBHFDPOOFDUJPOT required Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFECZVTJOH-FBSO.PEFPSUIF $#VT5PPMLJU4PGUXBSF C-BUSTM LIGHTING CONTROL + SENSORS C-BusTM 360° PIR Multi-Sensor 5IF$#VT5.¡1*3.VMUJ4FOTPSDPNCJOFTBQBTTJWFJOGSBSFESFDFJWFS1*3 GPS occupancy sensing, a light-level sensor, and an infrared remote receiver into a small, IJHIMZWFSTBUJMFVOJU5IFTFOTPSTJODIGBDFEJBNFUFSNBLFTJUVOPCUSVTJWFBOEJEFBMMZ TVJUFEGPSþVTINPVOUJOHPOUIFDFJMJOH $POýHVSBUJPOPQUJPOTGPSUIFPDDVQBODZTFOTPSJODMVEFBEKVTUBCMFUJNFEFMBZTGPS automatic shut-off following a preset time period without detected motion and an adjustable light-level sensor to turn on lights automatically when ambient light levels BSFMPXPSUVSOPGGMJHIUTXIFOBNCJFOUMJHIUMFWFMTBSFTVGýDJFOU5IFCVJMUJO*3SFDFJWFS BDDFQUTDPNNBOETGSPNBOPQUJPOBMIBOEIFMESFNPUFDPOUSPMMFSNBLJOHUIFTFOTPS ideal for classrooms and conference room areas. ¡1*3.VMUJ4FOTPS Product Features Technical Information /PNJOBM7PMUBHF3FRVJSFNFOUT7ED!N"ESBXOGSPNUIF$#VTOFUXPSL 'JFMEPG7JFX ¡ 1*33BUFE 5ZQJDBMMZTRGUTRN XIFOTFOTPSJT %FUFDUJPO'JFME NPVOUFEGUN BCPWFþPPS *33FDFJWFS3BUFE 5ZQJDBMMZTRGUTRN XIFOTFOTPSJT %FUFDUJPO'JFME NPVOUFEGUN BCPWFþPPS -JHIU-FWFMJOIJCJU5ISFTIPME GPPUDBOEMFMVY UPGVMMTVOMJHIU 5JNFS%FMBZ TFDUPIS /VNCFSPG6OJUT QFS/FUXPSL 6TFUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZUP EFUFSNJOFUIFUPUBMOFUXPSLDVSSFOUMPBE $#VT$POOFDUJPO 5XPSFNPWBCMFUFSNJOBMCMPDLTSFRVJSFT$"5EBUBDBCMF Status Indicators PIR Sensor or IR Receiver (activity) PIR Sensor (enabled/disabled) -JHIU-FWFM.BJOUFOBCMFEEJTBCMFE %JNFOTJPOT JO- YJO8 <NN- YNN8 > 8FJHIU P[H .PVOUJOH 4VSGBDF$FJMJOH )UGUN BCPWFþPPS .BY)UGUN BCPWFþPPS .JO$FJMJOH5IJDLOFTTJONN Operating Indoor only &OWJSPONFOU ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% t¡EFUFDUJPOQBUUFSOJOEPPSVTF t&GGFDUJWFEFUFDUJPOBSFBPGPDDVQBODZTFOTPS JTNPSFUIBOTRVBSFGFFUXIFOVOJUJT NPVOUFEGFFUBCPWFUIFþPPS&GGFDUJWF*3 DPWFSBHFJTTRVBSFGFFU t%VBMFMFNFOUEFUFDUPSTNJOJNJ[FGBMTF triggering t-&%TJOEJDBUFNPWFNFOUEFUFDUJPOBOETUBUVT of the IR receiver, the occupancy sensor, and the light-level sensor t$BODPOUSPMVQUPFJHIU$#VTTDFOFTPS EJSFDUMZDPOUSPMVQUPFJHIU$#VTHSPVQ addresses that can be individually scheduled t"EKVTUBCMFMJHIUMFWFMTFOTPSIBT4VOSJTF 4VOTFUBOEDMPDLPWFSSJEFT t"UUSBDUJWFMPXQSPýMFVOJUDBOCFþVTI mounted on ceiling or suspended from wall tiles where it is unobtrusive, with a face EJBNFUFSPGPOMZJODIFT t0QUJPOBMIBOEIFMESFNPUFDPOUSPMMFS 4-$594-$59 t/POWPMBUJMFNFNPSZTUPSFTPQFSBUJOHTUBUVT for recovery from a power outage t3FDFJWFTEBUBBOEQPXFSPWFSBOFUXPSLTP UIFTFOTPSEPFTOPUSFRVJSFQPXFSQBDLTPS line voltage connections Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFECZVTJOH-FBSO.PEFPSUIF $#VT5PPMLJU4PGUXBSF *For Diagram see technical section page 102 Catalog Number Description Accessories 4-$1&*3- ¡1*3.VMUJ4FOTPS 4-$59*3#VUUPO3FNPUF$POUSPMMFSPSEFSFETFQBSBUFMZ 4-$59*3#VUUPO3FNPUF$POUSPMMFSPSEFSFETFQBSBUFMZ 48 C-BUSTM LIGHTING CONTROL + SENSORS C-BusTM Outdoor Motion Sensor 5IF$#VT5.0VUEPPS1*3.PUJPO4FOTPSDPNCJOFTSFMJBCMFUIFSNBMSBEJBUJPOCBTFE DPOUSPMPGMJHIUJOHXJUISVHHFEDPOTUSVDUJPOTVJUBCMFGPSPVUEPPSSFRVJSFNFOUT5IFVOJUT BEWBODFEDJSDVJUTBOEþBUNVMUJTFHNFOUFEMFOTQSPWJEFDPWFSBHFPGVQUPTRVBSF GFFUJOB¡ýFMEPGWJFX 5IFEFUFDUJPOBSFBJODPSQPSBUFTBNVMUJGBDFUFEMFOTXIJDIFOTVSFTGBTUSFTQPOTFUP motion and few dead zones. Electrostatic and electromagnetic shields, dual element detectors, an optical bandpass filter, and pyroelectric ceramic sensors are used to reduce the incidence of false triggering. $POýHVSBUJPOPQUJPOTJODMVEFBOBEKVTUBCMFMJHIUMFWFMTFOTPSUIBUDBOCFTFUUP automatically turn off lights when ambient light levels are sufficient or turn on lights when ambient light levels are insufficient. 0VUEPPS1*3.PUJPO4FOTPS Technical Information Product Features /PNJOBM7PMUBHF3FRVJSFNFOUT7ED!N"ESBXOGSPNUIF$#VTOFUXPSL 'JFMEPG7JFX ¡ 1*3%FUFDUJPO'JFME 5ZQJDBMMZTRGUTRN -JHIU-FWFMJOIJCJU5ISFTIPME GPPUDBOEMFMVY UPGVMMTVOMJHIU /VNCFSPG%FUFDUJPO;POFT -POH3BOHF*OUFSNFEJBUF3BOHF4IPSU3BOHFVMUSB4IPSU 5JNFS%FMBZ3BOHF TFDUPIS /VNCFSPG6OJUT QFS/FUXPSL 6TFUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZUP EFUFSNJOFUIFUPUBMOFUXPSLDVSSFOUMPBE $#VT$POOFDUJPO 4UBUVT*OEJDBUPST %JNFOTJPOT 0OFUFSNJOBMCMPDL -&%DBOCFDPOýHVSFEUPUVSOPOXIFONPWFNFOUJTEFUFDUFE JO- YJO8 YJO% <NN- YNN8 YNN% > 8FJHIU P[H .PVOUJOH 4UBOEBSEQMBUFCPYXJUIJONN NPVOUJOHDFOUFST 4VSGBDF$FJMJOHPSXBMM )UGUN BCPWFþPPS Operating Outdoor only &OWJSPONFOU ¡'UP¡'¡$UP¡$ 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 102 49 Catalog Number Description 4-$81- ¡0VUEPPS1*3.PUJPO4FOTPS t0VUEPPSVTFXBMMPSDFJMJOHNPVOUFEVOJUXJUI B¡ýFMEPGWJFXBOEBEFUFDUJPOBSFBVQUP TRVBSFGFFUJOEJBNFUFS t-FOTIBTPWFSMBQQJOH[POFTPOFBDIPG levels, forming a continuous detection field t3VHHFEDPOTUSVDUJPOBOEQSFXJSFEþFYJCMF cord t-&%JOEJDBUFTNPUJPOEFUFDUJPO t-JHIUMFWFMTFOTPSIBT4VOSJTF4VOTFU TFUUJOHTDMPDLPWFSSJEFTBOEBEKVTUBCMF sensitivity ranging from 0.1 footcandle to full sunlight t$POUSPMTVQUPGPVS$#VTHSPVQBEESFTTFT that can be individually scheduled t/POWPMBUJMFNFNPSZTUPSFTPQFSBUJOHTUBUVT for recovery from a power outage t3FDFJWFTEBUBBOEQPXFSPWFSBOFUXPSLTP UIFTFOTPSEPFTOPUSFRVJSFQPXFSQBDLTPS line voltage connections Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFECZVTJOH-FBSO.PEFPSUIF $#VT5PPMLJU4PGUXBSF C-BUSTM LIGHTING CONTROL + SENSORS C-BusTM Light-Level Sensor 5IF$#VT5.-JHIU-FWFM4FOTPSNFBTVSFTBNCJFOUMJHIUMFWFMTBOEBVUPNBUJDBMMZJTTVFT 0/0''PSSBNQDPNNBOETPWFSB$#VTOFUXPSL5IFMJHIUMFWFMTFOTPSDBODPOUSPM SFMBZTEJNNFSTPSSFNPUFMZPQFSBUFEDJSDVJUCSFBLFSTDIBOHJOHUIFJSTUBUVTBDDPSEJOH to pre-set ambient lighting levels. 5IF$#VTMJHIUMFWFMTFOTPSIBTBEZOBNJDSBOHFCFUXFFOGPPUDBOEMFTBOE DPNQFOTBUFTGPSOPJTFBOESBQJEMJHIUJOUFOTJUZþVDUVBUJPOTCZVTJOHýMUFSJOHBOE hysteresis. 5IFMJHIUMFWFMTFOTPSDBODPOUSPMVQUPUXP$#VTHSPVQBEESFTTFTPOFBEESFTT controls the switching ON/OFF of a lamp circuit according to the amount of ambient light, while the other is used to continuously regulate the light-level output of any number of lamps. -JHIU-FWFM4FOTPS Technical Information Product Features /PNJOBM7PMUBHF3FRVJSFNFOUT7ED!N"ESBXOGSPNUIF$#VTOFUXPSL -JHIU-FWFM 3FBETGPPUDBOEMFTMVY $POUSPMTGPPUDBOEMFTMVY 'JFMEPG7JFX ¡ $#VT$POOFDUJPO "DDPNNPEBUFTY"8(DBCMFYNN2) 4UBUVT*OEJDBUPST $BOCFDPOýHVSFEUPSFQPSUTUBUFPGBOZPOF PGUISFFHSPVQBEESFTTFT&OBCMFE0/0''PS3BNQ %JNFOTJPOT JO- YJO8 YJO% <NN- YNN8 YNN% > 8FJHIU P[H Operating Indoor only &OWJSPONFOU ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 102 Catalog Number 4-$1& t$ BONBJOUBJODPOTUBOUJMMVNJOBUJPOMFWFMTPG 5-150 footcandles t$ POUSPMTVQUPUXP$#VTHSPVQBEESFTTFT one set for ON/OFF operations and one set for ramping operations t¡ýFMEPGWJFX t$ BOCFFOBCMFEPSEJTBCMFEPWFSUIF$#VT OFUXPSL t4 UPSFTPQFSBUJOHTUBUVTJOOPOWPMBUJMF memory for recovery from a power outage t3 FDFJWFTEBUBBOEQPXFSPWFSBTJOHMF$#VT twisted pair cable t7 FSJýFTTUBUVTPGJOQVUBOEPVUQVUEFWJDFTPO TBNF$#VTBQQMJDBUJPOBEESFTTVQEBUJOH input status if necessary t &%DBOCFDPOýHVSFEUPJOEJDBUFDVSSFOU TUBUVTPGBOZ$#VTHSPVQBEESFTT t" UUSBDUJWFXBMMNPVOUFEMPXQSPýMFVOJU Distributed Intelligence t$ PNQBUJCMFXJUIBMM$#VTEFWJDFT t& BTJMZDPOýHVSFECZVTJOHUIF$#VT5PPMLJU Software and a personal computer connected UPUIF$#VTOFUXPSL Description -JHIU-FWFM4FOTPS 50 C-BUSTM LIGHTING CONTROL + SENSORS C-BusTM Outdoor Light-Level Sensor 5IF$#VT5. light-level sensor measures ambient light levels and automatically issues 0/0''PSSBNQDPNNBOETPWFSB$#VTOFUXPSLUPNBJOUBJOPVUEPPSMJHIUJOHMFWFMT Primarily designed for outdoor use, this light-level sensor is also suitable for indoor settings in which a water resistant casing is desirable. 0VUEPPS-JHIU-FWFM4FOTPS Technical Information Product Features /PNJOBM7PMUBHF3FRVJSFNFOUTo7ED!N"ESBXOGSPNUIF$#VTOFUXPSL 'JFMEPG7JFX ¡ -JHIU-FWFM3BOHF 3FBETGPPUDBOEMFTMVY $POUSPMTGPPUDBOEMFTMVY $#VT$POOFDUJPO 4DSFXUZQFJOQVUUFSNJOBMTBDDPNNPEBUFY"8(DBCMFYNN¤ $POOFDUJPOSFRVJSFT$"5EBUBDBCMF .BY6OJUT/FUXPSL #BTFEPOUIFUPUBMOFUXPSLDVSSFOUMPBEBOEBWBJMBCMFQPXFS $POEVJU0QFOJOHT %JNFOTJPOT 4J[FEGPSNNBOENNDPOEVJUýUUJOHT JO- YJO8 YJO% <NN- YNN8 YNN% > 8FJHIU P[H .PVOUJOH *OEPPSPSPVUEPPSXBMMPSDFJMJOH *OEPPS)FJHIU"UMFBTUGUN BCPWFþPPS 0QFSBUJOH&OWJSPONFOU 0VUEPPSPSJOEPPSo¡'UP¡'o¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET '$$1BSU$MBTT#%JHJUBM%FWJDF *For Diagram see technical section page 102 Catalog Number 4-$1&81 51 t0 VUEPPSVTFXBMMBOEDFJMJOHNPVOUFE low-profile unit t$ BONBJOUBJOBDPOTUBOUJMMVNJOBUJPOMFWFM of 5-150 footcandles t$ POUSPMPGVQUPUXP$#VTHSPVQBEESFTTFT t4 FOTPSTSFDFJWFEBUBBOEQPXFSPWFSBTJOHMF $#VTUXJTUFEQBJSDBCMFTPUIFZEP OPUSFRVJSFQPXFSQBDLTPSMJOFWPMUBHF connections t ¡ýFMEPGWJFX Description 0VUEPPS-JHIU-FWFM4FOTPS Distributed Intelligence C-BUSTM LIGHTING CONTROL + OUTPUT UNITS C-BusTM Professional Series Dimmer 5IF$#VT5.1SPGFTTJPOBM%JNNFSTBSFEFTJHOFEUPDPOUSPMJODBOEFTDFOUBOE DPNQBUJCMFMPXWPMUBHFMJHIUJOH5IFTFEJNNFSTBSFJEFBMGPSUJHIUTQBDFBQQMJDBUJPOT XIFSFUSBEJUJPOBMSBDLNPVOUFEBTTFNCMJFTBSFOPUQSBDUJDBM 1SPGFTTJPOBMEJNNFSVOJUTBSFBWBJMBCMFJO"DIBOOFMT "UXPDIBOOFMT BOE "POFDIBOOFM NPEFMT&BDIDIBOOFMQSPWJEFTJOEFQFOEFOUEJNNJOHBOEJODPSQPSBUFT UIFSNBMPWFSMPBEBOEPWFSDVSSFOUQSPUFDUJPO5IFTFEJNNFSVOJUTBVUPNBUJDBMMZ DPNQFOTBUFGPSWPMUBHFBOEGSFRVFODZþVDUVBUJPOTBOEFNQMPZBEWBODFEQIBTFDPOUSPM UFDIOJRVFTUPSFEVDFþJDLFSBOEJODSFBTFMBNQMJGF 5IFBMVNJOVNFODMPTVSFBDUTBTBIFBUTJOLBOEJTEFTJHOFEGPSFBTZXBMMNPVOUJOH JODMVEJOHLFZIPMFNPVOUTBOESFNPWBCMFUFSNJOBMTGPSUIF$#VTBOEPWFSSJEF DPOOFDUJPOT"OPQUJPOBMUFSNJOBMCPYJTBWBJMBCMFGPSDPOEVJUDPOOFDUJPOT $POýHVSBUJPOPQUJPOTJODMVEFOFUXPSLNPOJUPSJOHPGUIFDIBOOFMMPBEBOEOFUXPSL voltages, adjustable delays for dimming levels, and master override. "$IBOOFM1SPGFTTJPOBM%JNNFS6OJU Product Features Technical Information /PNJOBM7PMUBHF3FRVJSFNFOUT $#VTWPMUBHFo7ED /PNJOBM-JOF4VQQMZ 7PMUBHFBOE'SFRVFODZ o7BD)[ 6TFBCMF0VUQVU$VSSFOU N" 'SFRVFODZ%SJGU )[QFSNJOVUFNBYJNVN 'SFRVFODZ4UFQ$IBOHF )[NBYJNVN .JOJNVN-PBE 8QFSDIBOOFM $VSSFOU4FOTJOH oPGGVMMSBUFEMPBEBDDVSBDZ &GýDJFODZ /VNCFSPG6OJUTQFS/FUXPSL $#VT$POOFDUJPOT 6TFUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZ UPEFUFSNJOFUIFUPUBMOFUXPSLDVSSFOUMPBE 'PVSXBZSFNPWBCMFTDSFXUFSNJOBMT$"5651DBCMFSFRVJSFE -PBE5FSNJOBMT "DDPNNPEBUFTPOFPSVQUPUXP"8(DBCMF <NN2NN2 > "VYJMJBSZ$POUBDUT "!7BDOPSNBMMZPQFOWPMUBHFGSFFSFTJTUJWF 4UBUVT*OEJDBUPST %JNFOTJPOT $IBOOFM6OJUBOE$#VT JO- YJO8 YJO) <NN- YNN8 YNN) > 8FJHIU t4VJUBCMFGPSVTFXJUISFTJTUJWFBOEJOEVDUJWF loads and low-voltage lamps utilizing iron core or electronic transformers t2VJDLNPVOUJOHEFTJHOJODMVEJOHLFZIPMF mounts, front and rear cable access, and SFNPWBCMFUFSNJOBMTGPS$#VTDPOOFDUJPOT t4QFDJBMJ[FEEJNNJOHNPEFToTPGUUVSOPOPGG and linearized brightness control t#VJMUJOQPXFSTVQQMZTPVSDFTN"UPUIF $#VTOFUXPSL t$PNQFOTBUFTGPSþVDUVBUJPOTJOGSFRVFODZ and voltage of power source t.POJUPSTMPBEDVSSFOUCZDIBOOFM t*OUFHSBMUIFSNBMPWFSMPBEQSPUFDUJPOPOFBDI channel t*OEJWJEVBMDIBOOFMTDBOCFUVSOFE0O0GGBU UIFVOJUPSWJB$#VTDPNNBOET t-&%TJOEJDBUFUIFTUBUVTPGUIFOFUXPSLBU UIFVOJUBOEUIFTUBUVTPGUIFVOJUTMPBEBOE power t0QUJPOBMUFSNJOBMCPYGPSDPOOFDUJOHDPOEVJU t/POWPMBUJMFNFNPSZTUPSFTPQFSBUJOHTUBUVT for recovery from a power outage MCLH 0QFSBUJOH&OWJSPONFOU Distributed Intelligence ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6-*OEVTUSJBM$POUSPM&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFEXJUIUIF$#VT5PPMLJU Software *For Diagram see technical section page 103 Catalog Number Description 4-$5% 1SPGFTTJPOBM%JNNFS"$IBOOFM7BD 4-$5% 1SPGFTTJPOBM%JNNFS"$IBOOFM7BD 4-$5% 1SPGFTTJPOBM%JNNFS"$IBOOFM7BD Accessories 4-$65# Description 5FSNJOBM#PY 52 C-BUSTM LIGHTING CONTROL + OUTPUT UNITS C-BusTM Phase Angle Dimmers 5IF$#VT5.1IBTF"OHMF%JNNFSTBSF$#VTDPOUSPMMFEPVUQVUVOJUTTVJUBCMFGPS JODBOEFTDFOUBOEDPNQBUJCMFMPXWPMUBHFMJHIUJOH5IFTFVOJUTBSFEFTJHOFEUPCFSBDL NPVOUFEJOTVJUBCMF%*/TUZMFFODMPTVSFT &BDIPGUIFVOJUTDIBOOFMTDBOJOEFQFOEFOUMZDPOUSPMMPBETUPDSFBUFEZOBNJDMJHIUJOH TDFOFT5IFTFEJNNFSVOJUTBVUPNBUJDBMMZDPNQFOTBUFGPSWPMUBHFBOEGSFRVFODZ þVDUVBUJPOTBOEFNQMPZBEWBODFEQIBTFDPOUSPMUFDIOJRVFTUPSFEVDFþJDLFSBOE increase lamp life. 1IBTF"OHMF%JNNFS6OJUXJUI1PXFS4VQQMZ Technical Information Product Features /PNJOBM7PMUBHF3FRVJSFNFOUTo7ED!N"GSPNUIF$#VTOFUXPSL when there is no external power source /PNJOBM-JOF4VQQMZ7PMUBHF and Frequency 7BDo)[ $#VT4PVSDF$VSSFOU N".PEFMT4-$5%"4-$5%" -PBE3BUJOHQFS$IBOOFM "4-$5%" "4-$5%" .JOJNVN-PBE 8QFSDIBOOFM &GýDJFODZ /VNCFSPG6OJUTQFS/FUXPSL 6TFUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZ UPEFUFSNJOFUIFUPUBMOFUXPSLDVSSFOUMPBE $#VT$POOFDUJPOT 3+DPOOFDUPST$"5651DBCMFSFRVJSFE $BCMF JONN QBUDIMFBEJODMVEFE 3FNPUF0WFSSJEF$POOFDUJPO 3+DPOOFDUPS 1PXFS5FSNJOBMT "DDPNNPEBUFo"8(DBCMF -PBE5FSNJOBMT YHBVHFPSYHBVHF 4UBUVT*OEJDBUPST %JNFOTJPOT $IBOOFM QFSDIBOOFM 6OJU 6OJUQPXFS $#VT 1PXFSMFWFMTBOEQSFTFODFPG$#VTDMPDL JO- YJO8 YJO) <NN- YNN8 YNN) > 8FJHIU P[H .PVOUJOH %*/SBJM.XJEF 0QFSBUJOH&OWJSPONFOU ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6-*OEVTUSJBM$POUSPM&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 103 Catalog Number 53 Description 4-$5%" 'PVS$IBOOFM"%JNNFSXJUIQPXFSTVQQMZ 4-$5%"1 'PVS$IBOOFM"%JNNFSXJUIPVUQPXFSTVQQMZ 4-$5%" &JHIU$IBOOFM"%JNNFSXJUIQPXFSTVQQMZ 4-$5%"1 &JHIU$IBOOFM"%JNNFSXJUIPVUQPXFSTVQQMZ t4VJUBCMFGPSVTFXJUIJODBOEFTDFOUMBNQT and low-voltage lamps utilizing iron core or electronic transformers tSpecialized dimming modes - soft turn On/Off and linearized brightness control. t$BOTVQQMZVQUPN"UPUIF$#VT OFUXPSLNPEFMT4-$5%"BOE 4-$5%"XJUICVJMUJOQPXFSTVQQMZ t*OUFHSBMUIFSNBMPWFSMPBEQSPUFDUJPOPOFBDI channel t*OEJWJEVBMDIBOOFMTDBOCFUVSOFE0/0''BU VOJUPSWJB$#VTDPNNBOET t-&%TJOEJDBUFUIFTUBUVTPGUIFOFUXPSLBU UIFVOJUUIFTUBUVTPGUIFVOJUTMPBEBOE power, and the status of each channel t/POWPMBUJMFNFNPSZTUPSFTPQFSBUJOHTUBUVT for recovery from a power outage Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFEXJUIUIF$#VT5PPMLJU Software C-BUSTM LIGHTING CONTROL + OUTPUT UNITS C-BusTM 2 Channel DALI Gateway 5IF$#VT5.%JHJUBM"EESFTTBCMF-JHIUJOH*OUFSGBDF%"-* (BUFXBZQSPWJEFTBOJTPMBUFE UXPXBZDPNNVOJDBUJPOTQBUICFUXFFOB$#VTOFUXPSLBOEUXP%"-*OFUXPSLT NBLJOHJUQPTTJCMFUPVTFUIF$#VTOFUXPSLUPDPOUSPMBOENPOJUPS%"-*CBMMBTUT 5IF%"-*HBUFXBZDPOTUBOUMZNPOJUPSTCPUI%"-*OFUXPSLTBOEDBOEFUFDUBOESFQPSU GBVMUZMBNQTJOþVPSFTDFOUCBMMBTUTPSOPOGVODUJPOBM%"-*CBMMBTUT %"-*(BUFXBZ Technical Information Product Features /PNJOBM7PMUBHF3FRVJSFNFOUT7ED!N"ESBXOGSPNUIF$#VTOFUXPSL &MFDUSJDBM*TPMBUJPO L73.4GSPNJOUFSGBDFUP$#VTOFUXPSL /VNCFSPG6OJUT QFS/FUXPSL $#VT$POOFDUJPOT %"-*$POOFDUJPOT 6TFUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZ UPEFUFSNJOFUIFUPUBMOFUXPSLDVSSFOUMPBE #VJMUJO3+TPDLFUT GPSDPOOFDUJPOUPUIF$#VTOFUXPSL 5XPTDSFXUZQFUFSNJOBMCMPDLTBDDPNNPEBUJOHo"8(DBCMF YNN2 or 1 x 2.5 mm2) $BCMF JONN QBUDIMFBEJODMVEFE 4UBUVT*OEJDBUPST %JNFOTJPOT 6OJU$PNNT6OJUQPXFSBOEEBUBUSBOTNJTTJPO $#VT1PXFSMFWFMTBOEQSFTFODFPG$#VTDMPDL JO- YJO8 YJO) <NN- YNN8 YNN) > 8FJHIU P[H .PVOUJOH %*/SBJM.XJEF 0QFSBUJOH&OWJSPONFOU ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 103 Catalog Number Description 4-$%"- 5XP$IBOOFM%"-*(BUFXBZ t1 SPWJEFTUXPXBZDPNNVOJDBUJPOTCFUXFFO $#VTBOE%"-*OFUXPSLTSPVUJOHTFMFDUFE messages from one to the other t6 OJUJTUSBOTQBSFOUBOEJOWJTJCMFUP%"-* ballasts t1 SFQSPHSBNNFE$#VTUP%"-*BOE%"-*UP $#VTBEESFTTJOHTUSVDUVSF t6 OJU$PNNTBOE$#VT-&%TTIPXUIF TUBUVTPGEBUBUSBOTNJTTJPOTUIFVOJUTQPXFS UIF$#VTOFUXPSLTQPXFSBOEUIFQSFTFODF PGUIF$#VTDMPDL t4 PGUXBSFTFMFDUBCMFOFUXPSLCVSEFOBOE OFUXPSLDMPDL t4 UBOEBSECVJMUJO$#VTOFUXPSLDPOOFDUPST 3+ t/ POWPMBUJMFNFNPSZUPTUPSFPQFSBUJOHTUBUVT for recovery from a power outage t3 FDFJWFTEBUBBOEQPXFSPWFSUIFOFUXPSL TPUIFVOJUEPFTOPUSFRVJSFQPXFSQBDLTPS line-voltage connections Distributed Intelligence t$ PNQBUJCMFXJUIBMM$#VTEFWJDFT t$ #VTTJEFPGJOUFSGBDFJTFBTJMZDPOýHVSFE XJUIUIF$#VT5PPMLJU4PGUXBSF 54 C-BUSTM LIGHTING CONTROL + OUTPUT UNITS C-BusTM 4 Channel 0-10V Fluorescent Ballast Dimmer 5IF$#VT5.$IBOOFM7'MVPSFTDFOU#BMMBTU%JNNFSQSPWJEFTGPVSDIBOOFMTPG BOBMPH7EDUIBUDBOCFVTFEBTUIFDPOUSPMTJHOBMTGPSWBSJPVTQFSJQIFSBMEFWJDFT JODMVEJOHFMFDUSPOJDBMMZEJNNBCMFþVPSFTDFOUMJHIUJOHCBMMBTUT 5IJTBOBMPHPVUQVUVOJUDBOTJOLPSTPVSDFDVSSFOUBTBQQSPQSJBUFGPSUIFDPOOFDUFEMPBE BOEQSPEVDFT7JOSFTQPOTFUPDPNNBOETGSPNUIF$#VTOFUXPSL &BDIDIBOOFMDBOCFJOEJWJEVBMMZBEKVTUFEGSPNUPBUUIFVOJUCZ$#VT commands or remotely, and each can drive multiple loads. DIBOOFM7'MVPSFTDFOU#BMMBTU%JNNFS Product Features Technical Information 1PXFS3FRVJSFNFOUT $#VTo7ED!N"SFRVJSFEGPSOPSNBMPQFSBUJPO 1PXFS7PS7BDDPOOFDUJPO8 /VNCFSPG6OJUT QFS/FUXPSL 6TFUIF$#VT$BMDVMBUPSBTPGUXBSFVUJMJUZUP EFUFSNJOFUIFUPUBMOFUXPSLDVSSFOUMPBE &MFDUSJDBM*TPMBUJPO L73.4GSPN$#VTUPUIFMJOF 0VUQVU7PMUBHF3BOHF 7ED 0VUQVU3BUJOH 4UBUVT*OEJDBUPST 4PVSDJOHN"NJOJNVNPGLPIN 4JOLJOHN"BU7out7 N"BU7out7 <JF*Y7out N"> 6OJU6OJUQPXFS $#VT/FUXPSLWPMUBHFMFWFMBOEQSFTFODFPGTZTUFNDMPDL $#VT$POOFDUJPO $BCMF 0VUQVU5FSNJOBMT 3+UFSNJOBMT JONN $"5QBUDIMFBEXJUIQSFUFSNJOBUFE3+DPOOFDUPST "DDPNNPEBUFT9"8(PS9"8(DBCMFYNN2PSYNN2) .PVOUJOH %JNFOTJPOT %*/SBJM.XJEF JO- YJO8 YJO% <NN- YNN8 YNN% > 8FJHIU P[H 0QFSBUJOH&OWJSPONFOU ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE&OFSHZ.BOBHFNFOU&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 104 Catalog Number 55 Description 4-$-&5".1 "OBMPH0VUQVU6OJU77 4-$-&)".1 "OBMPH0VUQVU6OJU77 t1SPEVDFTGPVSJOEFQFOEFOUMZDPOUSPMMBCMF DIBOOFMTPG7EDGPSDPOUSPMMJOHEJNNBCMF lighting ballasts or other loads t&BDIDIBOOFMDBOTJOLPSTPVSDFDVSSFOUBOE drive multiple loads t5XP3+DPOOFDUPSTGBDJMJUBUFRVJDL DPOOFDUJPOTUPUIF$#VTOFUXPSLBOE between similar units t6OJUBOE$#VT-&%TTIPXUIFTUBUVTPGUIF VOJUBOEUIFOFUXPSL t/POWPMBUJMFNFNPSZTUPSFTPQFSBUJOHTUBUVT for recovery from a power outage tPS7BDNPEFMTBWBJMBCMF Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFECZVTJOH-FBSO.PEFPSUIF $#VT5PPMLJU4PGUXBSF C-BUSTM LIGHTING CONTROL + OUTPUT UNITS C-BusTM 10 Amp Relay Unit 5IF$#VT5.3FMBZTBSF%*/SBJMNPVOUFEVOJUTXJUIGPVSPSUXFMWFJOEFQFOEFOUWPMUBHF GSFFSFMBZDPOUBDUTGPSHFOFSBMTXJUDIJOHBQQMJDBUJPOT5IFZBSFTVJUBCMFGPSVTFXJUI SFTJTUJWFJOEVDUJWFJODBOEFTDFOUBOEþVPSFTDFOUMPBET Each channel is independently configurable and features a zero crossing magnetically MBUDIJOHSFMBZEFTJHOFEGPSTXJUDIJOHUIFIBSTIFMFDUSJDBMMPBETBTTPDJBUFEXJUIUPEBZT IJHIFGýDJFODZMJHIUJOHTZTUFNT-PDBMUPHHMFCVUUPOTBSFQSPWJEFEPOFBDIVOJUUPBMMPX JOEJWJEVBMDIBOOFMTUPCFUPHHMFEBUFBDIVOJUPSWJB$#VTOFUXPSLDPNNBOET3FNPUF ON and OFF facilities are available, permitting all channels to be turned ON or OFF XJUIPVU$#VT/FUXPSLDPNNVOJDBUJPOT $IBOOFM"NQ3FMBZ Technical Information Product Features /PNJOBM4VQQMZ7PMUBHF74-$537'4-$537'14-$537'BOE4-$537'1 74-$)37'4-$)37'14-$)37'BOE4-$)37'1 'SFRVFODZ3BOHFT )[ $#VT$#VT 4VQQMZ7PMUBHF o7ED!N"SFRVJSFEGPSQSPHSBNNJOH XIFOFMFDUSJDBMQPXFSTPVSDFJTOPUDPOOFDUFE 4PVSDFTN"UPUIF$#VT/FUXPSL with electrical power source connected (non-power supply versions) o7ED!N"JTSFRVJSFEGPSQSPHSBNNJOH when electrical power source is connected &MFDUSJDBMJTPMBUJPO L73.4GSPN$#VTUPQPXFSTPVSDF $POUBDU5ZQF 7PMUBHF'SFFNBHOFUJDBMMZMBUDIFE $#VT$POOFDUJPOT 3+DPOOFDUPST$"5651DBCMFSFR &MFDUSJDBM5FSNJOBMT "DDPNNPEBUFT PSVQUP "8(NN2 YNN2) 4UBUVT*OEJDBUPST $#VT*OEJDBUPS Unit Status Indicator -PBE*OEJDBUPS %JNFOTJPOT 8FJHIU t'PVSPSUXFMWFJOEFQFOEFOUMZPQFSBUJOH voltage free relay contacts t5XPDPOWFOJFOUCVJMUJO$#VTOFUXPSL DPOOFDUPST3+ t6OJUTBWBJMBCMFCPUIXJUIBOEXJUIPVUB N"QPXFSTVQQMZ t/POWPMBUJMFNFNPSZTUPSFTPQFSBUJOHTUBUVT for recovery from power outage t-&%*OEJDBUPSTTIPXUIFTUBUVTPGUIF OFUXPSLBOEUIFVOJU t-PBE3BUJOHBOEDIBOOFM"NQSBUFE relay) 3FTJTUJWF" *OEVDUJWF" 'MVPSFTDFOU" .PUPS" Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFEXJUIUIF$#VT5PPMLJU Software $IBOOFMYYJODIFTYYNN $IBOOFMYYJODIFTYYNN $IBOOFMP[H XP1PXFS4VQQMZ P[H X1PXFS4VQQMZ $IBOOFMP[H XP1PXFS4VQQMZ P[H X1PXFS4VQQMZ .PVOUJOH %*/SBJM$IBOOFM.XJEF$IBOOFM.XJEF 0QFSBUJOH&OWJSPONFOU ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE*OEVTUSJBM$POUSPM&RVJQNFOU $4"/P*OEVTUSJBM$POUSPM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/*NNVOJUZUP&4% *For Diagram see technical section page 104 Catalog Number Description 4-$537' $IBOOFM7"XQPXFSTVQQMZ 4-$537'1 $IBOOFM7"XPQPXFSTVQQMZ 4-$)37' $IBOOFM7"XQPXFSTVQQMZ 4-$)37'1 $IBOOFM7"XPQPXFSTVQQMZ 4-$537' $IBOOFM7"XQPXFSTVQQMZ 4-$537'1 $IBOOFM7"XPQPXFSTVQQMZ 4-$)37' $IBOOFM7"XQPXFSTVQQMZ 4-$)37'1 $IBOOFM7"XPQPXFSTVQQMZ 56 C-BUSTM LIGHTING CONTROL + OUTPUT UNITS C-BusTM 20 Amp Relay Units 5IF$#VT5."NQ3FMBZTBSF%*/SBJMNPVOUFEVOJUTXJUIGPVSJOEFQFOEFOUWPMUBHF GSFFSFMBZDPOUBDUT5IFZBSFTVJUBCMFGPSVTFXJUISFTJTUJWFJOEVDUJWFJODBOEFTDFOUBOE þVPSFTDFOUMPBET Each channel is independently configurable and features a zero crossing magnetically MBUDIJOHSFMBZEFTJHOFEGPSTXJUDIJOHUIFIBSTIFMFDUSJDBMMPBETBTTPDJBUFEXJUIUPEBZT IJHIFGýDJFODZMJHIUJOHTZTUFNT-PDBMUPHHMFCVUUPOTBSFQSPWJEFEPOFBDIVOJUUPBMMPX JOEJWJEVBMDIBOOFMTUPCFUPHHMFEBUFBDIVOJUPSWJB$#VTOFUXPSLDPNNBOET3FNPUF ON and OFF facilities are available, permitting all channels to be turned ON or OFF XJUIPVU$#VT/FUXPSLDPNNVOJDBUJPOT $IBOOFM"3FMBZ Technical Information /PNJOBM4VQQMZ7PMUBHF Product Features 74-$537'BOE4-$537'1 74-$)37'BOE4-$)37'1 'SFRVFODZ3BOHFT )[ $#VT4VQQMZ7PMUBHF o7ED!N"SFRVJSFEGPSQSPHSBNNJOH when electrical power source is not connected. 4PVSDFTN"UPUIF$#VT/FUXPSLXJUI electrical power source connected. &MFDUSJDBMJTPMBUJPO L73.4GSPN$#VTUPQPXFSTPVSDF $POUBDU5ZQF 7PMUBHF'SFFNBHOFUJDBMMZMBUDIFE $#VT$POOFDUJPOT 3+DPOOFDUPST$"5651DBCMFSFR &MFDUSJDBM5FSNJOBMT "DDPNNPEBUFT PSVQUP "8( YNN2PSYNN2) 4UBUVT*OEJDBUPST $#VT*OEJDBUPS Unit Status Indicator -PBE*OEJDBUPS %JNFOTJPOT YYJODIFTYYNN 8FJHIU P[H .PVOUJOH %*/SBJM.XJEF ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH Operating EnviSPONFOU 4UBOEBSET 6-*OEVTUSJBM$POUSPM&RVJQNFOU $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF &/-PX'SFRVFODZ&NJTTJPOT *For Diagram see technical section page 104 57 Catalog Number Description 4-$537' $IBOOFM7"XJUIQPXFSTVQQMZ 4-$537'1 $IBOOFM7"XJUIPVUQPXFSTVQQMZ 4-$)37' $IBOOFM7"XJUIQPXFSTVQQMZ 4-$)37'1 $IBOOFM7"XJUIPVUQPXFSTVQQMZ t'PVSJOEFQFOEFOUMZPQFSBUJOHWPMUBHFGSFF relay contacts t5XPDPOWFOJFOUCVJMUJO$#VTOFUXPSL DPOOFDUPST3+ t6OJUTBWBJMBCMFCPUIXJUIBOEXJUIPVUB N"QPXFSTVQQMZ t/POWPMBUJMFNFNPSZTUPSFTPQFSBUJOHTUBUVT for recovery from power outage t-&%*OEJDBUPSTTIPXUIFTUBUVTPGUIF OFUXPSLBOEUIFVOJU t3FNPUF0/0''PWFSSJEFDBQBCJMJUJFT t-PBE3BUJOHDIBOOFM"NQSBUFESFMBZ 3FTJTUJWF" *OEVDUJWF" 'MVPSFTDFOU" .PUPS" Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFEXJUIUIF$#VT5PPMLJU Software C-BUSTM LIGHTING CONTROL + OUTPUT UNITS C-BusTM Changeover Relay Units 5IF$#VT5.$IBOHFPWFS3FMBZTBSF%*/SBJMNPVOUFEEFWJDFTXJUIGPVSJOEFQFOEFOU voltage free, changeover relay contacts. 4DIOFJEFS&MFDUSJD$#VT$IBOHFPWFS3FMBZTBSFEFTJHOFEUPPQFSBUFUISFFTQFFE motors and two-way motor control devices. Some of their most common applications JODMVEFPQFSBUJOHNPUPSJ[FECMJOETTIVUUFSTDVSUBJOTBOETLZMJHIUTPQFODMPTFE XIFSF UIFZQSPWJEFBNVDITJNQMFSBMUFSOBUJWFUPUSBEJUJPOBMBOEPCUSVTJWFSFMBZJOUFSMPDLJOH systems. $IBOHFPWFS3FMBZ6OJU Product Features Technical Information /PNJOBM4VQQMZ7PMUBHF 74-$537'$BOE4-$537'$1 74-$)37'$BOE4-$)37'$1 'SFRVFODZ3BOHFT )[ $#VT4VQQMZ7PMUBHF o7ED!N"SFRVJSFEGPSQSPHSBNNJOH when electrical power source is not connected. 4PVSDFTN"UPUIF$#VT/FUXPSL with electrical power source connected. &MFDUSJDBMJTPMBUJPO L73.4GSPN$#VTUPQPXFSTPVSDF $POUBDU5ZQF $IBOHFPWFS/POMBUDIJOH $#VT$POOFDUJPOT 3+DPOOFDUPST$"5651DBCMFSFR &MFDUSJDBM5FSNJOBMT "DDPNNPEBUFT PSVQUP "8( YNN2PSYNN2) 4UBUVT*OEJDBUPST $#VT*OEJDBUPS Unit Status Indicator -PBE*OEJDBUPS %JNFOTJPOT t'PVS JTPMBUFEJOEFQFOEFOUMZPQFSBUJOH relay channels t5XP DPOWFOJFOUCVJMUJO$#VTOFUXPSL DPOOFDUPST3+ t/POWPMBUJMFNFNPSZTUPSFTPQFSBUJOHTUBUVT for recovery from power outage t-&%*OEJDBUPSTTIPXUIFTUBUVTPGUIF OFUXPSLBOEUIFVOJU t$IBOHFPWFS3FMBZTSBUJOHT7"$.BY t"&YIBVTUGBOTTIBEFEQPMFJOEVDUJPO motors) t"$FJMJOHGBOTTQMJUQIBTFJOEVDUJPONPUPST Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFEXJUIUIF$#VT5PPMLJU Software YYJODIFTYYNN 8FJHIU P[H 8JUI1PXFS4VQQMZ P[H 8JUIPVU1PXFS4VQQMZ .PVOUJOH %*/SBJM.XJEF 0QFSBUJOH&OWJSPONFOU ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH 4UBOEBSET 6--JTUFE*OEVTUSJBM$POUSPM&RVJQNFOU $4"/P*OEVTUSJBM$POUSPM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDF *For Diagram see technical section page 105 Catalog Number Description 4-$537'$ $IBOOFMDIBOHFPWFSSFMBZVOJU7BDXJUIQPXFSTVQQMZ 4-$537'$1 $IBOOFMDIBOHFPWFSSFMBZVOJU7BDXJUIPVUQPXFSTVQQMZ 4-$)37'$ $IBOOFMDIBOHFPWFSSFMBZVOJU7BDXJUIQPXFSTVQQMZ 4-$)37'$1 $IBOOFMDIBOHFPWFSSFMBZVOJU7BDXJUIPVUQPXFSTVQQMZ 58 C-BUSTM LIGHTING CONTROL + OUTPUT UNITS C-BusTM Low Voltage Relay 5IF$#VT5.$IBOOFM-PX7PMUBHF3FMBZJTVTFEGPSTXJUDIJOHMPBETTVDIBTJSSJHBUJPO TPMFOPJETBOE-7BJSDPOEJUJPOJOHEBNQFST5IF3FMBZNBZBMTPCFVTFEGPSTXJUDIJOH-7 pulse signal control loads into third party products. 5IF$#VT$IBOOFM-PX7PMUBHF3FMBZJTB$#VTPVUQVUEFWJDFUIBUDPOUSPMTFJHIU MPXWPMUBHFSFMBZDIBOOFMT5IFVOJUJTQPXFSFEGSPNUIF$#VTOFUXPSLBOESFRVJSFT OPPUIFSQPXFSTPVSDF5IFVOJUDBOCFEBJTZDIBJOFEPSQMBDFEBUUIFFOEPGB$#VT OFUXPSL -PX7PMUBHF3FMBZ Product Features Technical Information $#VTOFUXPSLTVQQMZWPMUBHF UP7ED!N"SFRVJSFEGPSQSPHSBNNJOHBOEPQFSBUJPO .BYJNVNVOJUTQFS$#VTOFUXPSL $#VTDPOOFDUJPOT XJSFUXJTUFEQBJS 8BSNVQUJNF TFDPOET -PBESBUJOHQFSSFMBZDIBOOFM "BU7EDNBYJNVNPS 7BD3.4TVJUBCMFGPSSFTJTUJWFBOEJOEVDUJWFMPBET $POUBDUUZQF 3FMBZUFSNJOBMDPOOFDUJPOT $DPNNPO/0OPSNBMMZPQFO/$OPSNBMMZDMPTFE 7PMUBHFGSFF41%5DIBOHFPWFS 5ZQFTPGFMFDUSJDBMDPOOFDUJPO'JYFEMPBEUFSNJOBMGPSYNN¤XJSFQFSUVOOFM"8( 'JYFEBVY$#VT DPOOFDUPSTGPS %JNFOTJPOT8Y)Y% 8FJHIU P[H .PVOUJOHNPEF 4VSGBDFNPVOUJOHTDSFXIPMFTBOELFZIPMFNPVOU &.$FOWJSPONFOU &OWJSPONFOU" 0QFSBUJOHBNCJFOUUFNQFSBUVSF UP¡'UP¡$ 4UPSBHFUFNQFSBUVSF 0QFSBUJOHIVNJEJUZ YNN¤ YYJOYYNN UP¡'UP¡$ UPOPODPOEFOTJOH 4UBOEBSET $4"$/P4JHOBM&RVJQNFOU 6-&OFSHZ.BOBHFNFOU&RVJQNFOU'$$1BSU $MBTT#%JHJUBM%FWJDFGPS)PNFPS0GýDF6TF *For Diagram see technical section page 105 Catalog Number 4-$3&-71øøøøø 59 Description $#VT$IBOOFM-PX7PMUBHF3FMBZ t4PGUXBSFTFMFDUBCMF$#VTTZTUFNDMPDL t4ZODISPOJ[FEBUBDPNNVOJDBUJPOPOUIF $#VTOFUXPSL t4XJUDI-PX7PMUBHF-PBET t$POUSPMSEQBSUZQSPEVDUT t4UBUVT*OEJDBUPS-JHIUT 60 TM C-Bus Enclosures and Area Lighting Panels 61 Introduction to C-BusTM Enclosures and Area Lighting Panels "SFBMJHIUJOHQBOFMTGSPN4DIOFJEFS&MFDUSJD are a simple, convenient way to area dimming and multi-scene controls, as well as daylight harvesting schemes in an individual conference room or suite within a commercial CVJMEJOH5IFZBSFJEFBMMZTVJUFEUPNFFU energy code requirements related to reduction in lighting loads by dimming, or integrating natural light with artificial light. "SFBMJHIUJOHQBOFMTPGGFSUIFþFYJCJMJUZPGCFJOH set up as a stand-alone system or connected BTBQBSUPGBMBSHFS$#VT5.OFUXPSL" TJNQMF$BUDBCMFDPOOFDUJPOHJWFTUIF pre-engineered enclosed panels the ability to integrate light-level detection, occupancy EFUFDUJPOLFZQBETBOETXJUDIJOH"MPOHXJUI FBTFPGOFUXPSLDPOOFDUJWJUZBOETJNQMJýFE programming, area lighting panels also provide easy installation and reduced field-wiring costs. Outfitting a conference room or suite with a $#VTMJHIUMFWFMTFOTPSBMMPXTBOBSFBMJHIUJOH panel to automatically dim lights to capitalize POBWBJMBCMFOBUVSBMMJHIU8IFOVTJOH$#VT occupancy sensors, the panel automatically turns lights off after everyone leaves. "EEJUJPOBMMZWBSJPVTQSFQSPHSBNNFEMJHIUJOH scenes can be automatically executed by the QBOFMCZQSFTTJOHBCVUUPOPOB$#VTMJHIUJOH DPOUSPMLFZQBE "SFBMJHIUJOHQBOFMTQSPWJEFVOQBSBMMFMFE JOTUBMMBUJPOþFYJCJMJUZGPSFMFDUSJDBMDPOUSBDUPST 5IFZQSPWJEFUIFBCJMJUZUPJOUFHSBUF$#VT LFZQBETBOEMJHIUMFWFMTFOTPSTBOE occupancy sensors without the complexity of MJOFWPMUBHFXJSJOHDPOOFDUJPOT"TJOHMF$BU cable is all that is required in most applications to connect the inputs to a panel, which may be mounted in either an electrical closet or ceiling space. Power is distributed to the panel from a single home-run connection UPUIFQPXFSTPVSDF$POTVMUBOUTXJMMýOE that designing rooms in a commercial building with a focus on energy savings and tasteful lighting scenes is easier, because there is less wiring complexity. 62 C-BUSTM LIGHTING CONTROL + AREA LIGHTING PANEL C-BusTM Area Lighting Panels 5IF$#VT5."SFB-JHIUJOH1BOFMTBSFJEFBMMZTVJUFEUPNFFUMJHIUJOHDPOUSPMFOFSHZDPEF SFRVJSFNFOUTJODMBTTSPPNTPGýDFTBOEPUIFSTNBMMTQBDFT5IFTFEFWJDFTQSPWJEFUIF BCJMJUZUPJOUFHSBUFLFZQBETPDDVQBODZTFOTJOHMJHIUMFWFMEFUFDUJPOBOETXJUDIJOH XJUIPVUUIFNFTTPGDPNQMFYDPOUSPMXJSJOH"TJNQMF$"5DBCMFJTBMMUIBUJTSFRVJSFEUP DPOOFDUTFOTPSTBOELFZQBET "SFB-JHIUJOH1BOFMTDBOPQFSBUFBTJOEFQFOEFOUTUBOEBMPOFJTMBOETPSBTQBSUPGBO entire facility wide lighting control system. Enclosures can easily be mounted in electrical DMPTFUTPSJODFJMJOHTQBDFT5IFZJODMVEFBMMOFDFTTBSZDPOOFDUJPOTBOEBSF6- -JTUFE "SFB-JHIUJOH1BOFMTDBOCFVTFEGPSPOPGGTXJUDIJOHTUFQQFEEJNNJOHPSDPOUJOVPVT EJNNJOHBQQMJDBUJPOT"MMSFMBZTGFBUVSFSVHHFE"SBUFEDPOUBDUTGPSTXJUDIJOH FMFDUSPOJDCBMMBTUMPBET.PEFMTXJUIDPOUJOVPVTEJNNJOHDBQBCJMJUJFTBSFSBUFEGPSFJUIFS /&$$MBTTPS$MBTTXJSJOH Product Features Technical Information 3BUFE7PMUBHF 77)[ /VNCFSPG6OJUT QFS/FUXPSL 6TFUIF$#VTDBMDVMBUPSBTPGUXBSFVUJMJUZUP EFUFSNJOFUPUBMOFUXPSLDVSSFOUMPBEPS5PPMLJUTPGUXBSF &MFDUSJDBMJTPMBUJPO L73.4GSPN$#VTUPUIFMJOF 3FMBZT " 4IPSU$JSDVJU$VSSFOU3BUJOH L"7 L"7 $#VT$POOFDUJPOT 3+ Dimensions .&ODMPTVSF JOYJOYJO .&ODMPTVSF JOYJOYJO 4UBOEBSET DIBOOFM"3FMBZ"SFB-JHIUJOH1BOFM 6--JTUFE"'$$QBSU$MBTT#%FWJDF &/*NNVOJUZUP&4% *For Enclosure Diagram see technical section page 106 Catalog Number Enclosure t3FMBZNPEFMT'PVSPSFJHIUSFMBZPVUQVUT SBUFE" t7PVUQVUTGPSDPOUSPMPG7EJNNBCMF þVPSFTDFOUCBMMBTUTVJUBCMFGPSVTFXJUI."3, 7®4ZMWBOJB2VJDLUSPOJD®, and Universal 4VQFS%JN®) t*OUFHSBMOFVUSBMBOEHSPVOECBSUFSNJOBMTUSJQT t1MFOVNSBUFEGPSDFJMJOHBQQMJDBUJPOT t#ZQBTTNPEFUPGBDJMJUBUFRVJDLTUBSUVQ t.FFUT/&$"SUJDMF t6--JTUFE"4$$3DVSSFOUSBUJOHTL" 7 L"7 t4VSGBDF.PVOU/&."&ODMPTVSF Distributed Intelligence t$PNQBUJCMFXJUIBMM$#VTEFWJDFT t&BTJMZDPOýHVSFEXJUI-FBSO.PEFPSXJUI $#VT5PPMLJUTPGUXBSF Description $IBOOFM"3FMBZ.PEFMT 4-$;5 . $IBOOFM"3FMBZ!7XJUIQPXFSTVQQMZ 4-$;) . $IBOOFM"3FMBZ!7XJUIQPXFSTVQQMZ 4-$;51 . $IBOOFM"3FMBZ!7XJUIPVUQPXFSTVQQMZ 4-$;)1 . $IBOOFM"3FMBZ!7XJUIPVUQPXFSTVQQMZ $IBOOFM"3FMBZ.PEFMT 4-$;5 . $IBOOFM"3FMBZ!7XJUIQPXFSTVQQMZ 4-$;) . $IBOOFM"3FMBZ!7XJUIQPXFSTVQQMZ 4-$;51 . $IBOOFM"3FMBZ!7XJUIPVUQPXFSTVQQMZ 4-$;)1 . $IBOOFM"3FMBZ!7XJUIPVUQPXFSTVQQMZ $IBOOFM"3FMBZ!7XJUIQPXFSTVQQMZBOE$IBOOFM70VUQVU6OJU $IBOOFM"3FMBZ.PEFMTXJUI70VUQVU6OJUT 4-$;"5 . 4-$;") . $IBOOFM"3FMBZ!7XJUIQPXFSTVQQMZBOE$IBOOFM70VUQVU6OJU 4-$;"51 . $IBOOFM"3FMBZ!7XJUIPVUQPXFSTVQQMZBOE$IBOOFM70VUQVU6OJU 4-$;")1 . $IBOOFM"3FMBZ!7XJUIPVUQPXFSTVQQMZBOE$IBOOFM70VUQVU6OJU $IBOOFM1IBTF"OHMF%JNNFS.PEFMT 4-$;%5 . $IBOOFM1IBTF"OHMF%JNNFS!7XJUIQPXFSTVQQMZ 4-$;%51 . $IBOOFM1IBTF"OHMF%JNNFS!7XJUIPVUQPXFSTVQQMZ . $IBOOFM"3FMBZ!7XJUIQPXFSTVQQMZBOEDIBOOFMQIBTFBOHMFEJNNFSVOJU . $IBOOFM"3FMBZ!7XJUIPVUQPXFSTVQQMZBOEDIBOOFMQIBTFBOHMFEJNNFSVOJU $IBOOFM"3FMBZ.PEFMTXJUI1IBTF"OHMF%JNNFS6OJUT 4-$;%5 4-$;%51 * For stand-alone applications order unit with power supply 63 C-BUSTM LIGHTING CONTROL + ENCLOSURES C-BusTM 8M Enclosure 5IF$#VT5.&ODMPTVSFTQSPWJEFBIPVTJOHGPSWBSJPVT$#VT%*/NPVOUFEEFWJDFT5IF .FODMPTVSFJTTQFDJýDBMMZEFTJHOFEGPSEJTUSJCVUFEBQQMJDBUJPOTUIBUSFRVJSFQIZTJDBM QSPYJNJUZCFUXFFO%*/VOJUTBOELFZQBETTFOTPSTPSDPOUSPMMFEMPBET 4VJUBCMFGPSTVSGBDFNPVOUJOHUIF.FODMPTVSFDPOTJTUTPGBCPYXJUIBDPWFSBOEB %*/SBJMGPSNPVOUJOHPOF.PSUXP.VOJUT5IFFODMPTVSFBMTPIBTQSPWJTJPOTGPS mounting neutral and ground bars. .&ODMPTVSF Product Features Technical Information .&ODMPTVSF 5ZQF /&." %*/.PEVMF$BQBDJUZ 0OF.PSUXP.$#VTVOJUT %JNFOTJPOT JO- YJO8 YJO% <NN- YNN8 YNN% > .PVOUJOH %*/SBJM 8FJHIU MCLH t4VSGBDFNPVOU/&."FODMPTVSF t8FMEFETIFFUTUFFMXJUILOPDLPVUT t(SBZCBLFEFOBNFMFMFDUSPEFQPTJUFEPWFS cleaned, phosphatized steel t5SJQMFMFBEDPWFSTDSFXTGPSGBTUJOTUBMMBUJPOPG cover t%*/SBJMTVJUBCMFGPSNPVOUJOHPOF.PSUXP .$#VT%*/NPEVMFT t6--JTUFE *For Diagram see technical section page 105 Catalog Number Description Accessories 4-$. .%*/&ODMPTVSF 1,(5"(SPVOE/FVUSBM#BS† 1,(5"#/FVUSBM*OTVMBUPS,JU† 4-$$4' 'JMMFS1MBUF. *ODMVEFTPOFHSPVOECBSPOFýMMFSQMBUFDBCMFUJFTBOENPVOUTGPSXJSFNBOBHFNFOU p"EEJUJPOBMUFSNJOBMCBSBOEJOTVMBUPSGPSEFWJDFTUIBUSFRVJSFOFVUSBMDPOOFDUJPOQPJOUTGPSMPBETTVDIBTBSFMBZVOJU /PUF5IF$#VT.&ODMPTVSFXJMMBDDFQUPOFBEEJUJPOBMUFSNJOBUPSCBS1,(5" JOUFOEFEGPSMPBEOFVUSBMDPOOFDUJPOT 5IJTJTUPCFVTFEXIFOUIF$#VTVOJUNPVOUFEJOTJEFSFRVJSFTOFVUSBMDPOOFDUJPOQPJOUTGPSMPBETJFBSFMBZVOJU6TFJODPOKVODUJPOXJUIB/FVUSBM*OTVMBUPS,JU1,(5"# 64 C-BUSTM LIGHTING CONTROL + ENCLOSURES C-BusTM 12M Enclosure 5IF$#VT5.&ODMPTVSFTQSPWJEFBIPVTJOHGPSWBSJPVT$#VT%*/NPVOUFEEFWJDFT 5IF.FODMPTVSFJTTQFDJýDBMMZEFTJHOFEGPSEJTUSJCVUFEBQQMJDBUJPOTUIBUSFRVJSF QIZTJDBMQSPYJNJUZCFUXFFO%*/VOJUTBOELFZQBETTFOTPSTPSDPOUSPMMFEMPBET 4VJUBCMFGPSTVSGBDFNPVOUJOHUIF.FODMPTVSFDPOTJTUTPGBCPYXJUIBDPWFSBOE B%*/SBJMGPSNPVOUJOHUISFF.$#VTVOJUTPOF.VOJUQMVTPOF.VOJUPSPOF .VOJU5IFFODMPTVSFBMTPIBTGBDUPSZNPVOUFEOFVUSBMBOEHSPVOECBST .&ODMPTVSF Product Features Technical Information 12M Enclosure 5ZQF /&." %*/.PEVMF$BQBDJUZ %JNFOTJPOT 0OF.POF.POF.PSUISFF.$#VTVOJUT JO8 YJO- YJO% <NN8 YNN- YNN% > 4UBOEBSE 6-4UBOEBSE&ODMPTVSFTGPSFMFDUSJDBMFRVJQNFOU .PVOUJOH %*/SBJM 8FJHIU MCLH t4VSGBDFNPVOU/&."FODMPTVSF t8FMEFETIFFUTUFFMXJUILOPDLPVUT t(SBZCBLFEFOBNFMFMFDUSPEFQPTJUFEPWFS cleaned, phosphatized steel t5SJQMFMFBEDPWFSTDSFXTGPSGBTUJOTUBMMBUJPO of cover t%*/SBJMTVJUBCMFGPSNPVOUJOHPOF.PS UISFF.PSPOF.BOEPOF.$#VT%*/ module t6--JTUFE *For Diagram see technical section page 106 Catalog Number Description Accessories 4-$.4( .%*/&ODMPTVSF 1,(5"(SPVOE/FVUSBM#BS 1,(5"#/FVUSBM*OTVMBUPS,JU *ODMVEFTPOF%*/SBJMPOFHSPVOECBSBOEPOFJOTVMBUFEOFVUSBMUFSNJOBMCBSQSFJOTUBMMFEPOUIFNPVOUJOHQBO"MTPJODMVEFEBSFGUPGþFYJCMF$MBTTCBSSJFSGPVSQBONPVOUJOH TDSFXTGPVSDPWFSNPVOUJOHTDSFXTBOEUXP%*/SBJMTUPQT 65 C-BUSTM LIGHTING CONTROL + ENCLOSURES C-BusTM 24M Enclosure 5IF$#VT5.&ODMPTVSFTQSPWJEFBIPVTJOHGPSWBSJPVT$#VT%*/NPVOUFEEFWJDFT5IF .FODMPTVSFJTTQFDJýDBMMZEFTJHOFEGPSEJTUSJCVUFEBQQMJDBUJPOTUIBUSFRVJSFQIZTJDBM QSPYJNJUZCFUXFFO%*/VOJUTBOELFZQBETTFOTPSTPSDPOUSPMMFEMPBET 4VJUBCMFGPSTVSGBDFNPVOUJOHUIF.FODMPTVSFDPOTJTUTPGBCPYXJUIBIJOHFEEPPSBOE UXPSPXTGPSNPVOUJOH$#VT%*/NPVOUFEVOJUT&BDISPXDBOIPMEPOF.VOJUPOF .VOJUQMVTPOF.VOJUPSUISFF.VOJUT5IFFODMPTVSFBMTPIBTQSPWJTJPOTGPSBEEJUJPOBM neutral and ground bars. .&ODMPTVSF Product Features Technical Information 24M Enclosure 5ZQF /&." %*/.PEVMF$BQBDJUZ 5XPSPXTGPSNPVOUJOH$#VT%*/NPVOUFEVOJUT&BDISPXDBO %JNFOTJPOT IPMEPOF.VOJUPOF.VOJUQMVTPOF.VOJUPSUISFF.VOJUT JO8 YJO- YJO% <NN8 YNN- YNN% > .PVOUJOH %*/SBJM 4UBOEBSE 6-4UBOEBSE&ODMPTVSFTGPSFMFDUSJDBMFRVJQNFOU 8FJHIU MCLH t4VSGBDFNPVOU/&."FODMPTVSF t8FMEFETIFFUTUFFMXJUILOPDLPVUT t(SBZCBLFEFOBNFMFMFDUSPEFQPTJUFEPWFS cleaned, phosphatized steel t5SJQMFMFBEDPWFSTDSFXTGPSGBTUJOTUBMMBUJPO of cover t)JOHFEUSJNGPSFBTZBDDFTT t%*/SBJMTVJUBCMFGPSNPVOUJOH$#VT%*/ NPVOUFE$#VTVOJUT&BDISPXDBOIPMEPOF .VOJUPOF.VOJUQMVTPOF.VOJUPS UISFF.VOJUT t6--JTUFE *For Diagram see technical section page 106 Catalog Number Description Accessories 4-$.4( .%*/&ODMPTVSF 1,(5"(SPVOE/FVUSBM#BS† 1,(5"# /FVUSBM*OTVMBUPS,JUp 5IFFODMPTVSFDPNFTXJUIUXP%*/SBJMTUXPHSPVOECBSTBOEUXPJOTVMBUFEOFVUSBMUFSNJOBMCBSTQSFJOTUBMMFEPOUIFNPVOUJOHQBO"MTPJODMVEFEBSFGUPGþFYJCMF$MBTTCBSSJFS GPVSQBONPVOUJOHTDSFXTBOEGPVSEPPSNPVOUJOHTDSFXTBOEGPVS%*/SBJMTUPQT p"EEJUJPOBMUFSNJOBMCBSBOEJOTVMBUPSGPSEFWJDFTUIBUSFRVJSFOFVUSBMDPOOFDUJPOQPJOUTGPSMPBETTVDIBTBSFMBZVOJU /PUF5IF$#VT.&ODMPTVSFXJMMBDDFQUPOFBEEJUJPOBMUFSNJOBUPSCBS1,(5" JOUFOEFEGPSMPBEOFVUSBMDPOOFDUJPOT5IJTJTUPCFVTFEXIFOUIF$#VTVOJU NPVOUFEJOTJEFSFRVJSFTOFVUSBMDPOOFDUJPOQPJOUTGPSMPBETJFBSFMBZVOJU6TFJODPOKVODUJPOXJUIB/FVUSBM*OTVMBUPS,JU1,(5"# 66 C-BUSTM LIGHTING CONTROL + ENCLOSURES C-BusTM 36M Enclosures 5IF$#VT5.&ODMPTVSFTQSPWJEFBNVMUJQVSQPTFNFBOTGPSIPVTJOHWBSJPVT$#VT %*/NPVOUFEEFWJDFT4VJUBCMFGPSþVTIPSTVSGBDFNPVOUJOHUIFFODMPTVSFDPOTJTUTPG BDBCJOFUBNPVOUJOHQBOBTTFNCMZBOEBDPWFSBTTFNCMZ5IFDBCJOFUDBOCFPSEFSFE TFQBSBUFMZBMMPXJOHGPSJUTJOTUBMMBUJPOXJUIUIFSPVHIJOPGýFMEXJSJOH5IFNPVOUJOH QBODPNFTXJUIPOF-CBSSJFSGPVSIPSJ[POUBMCBSSJFSTBOEUISFF%*/SBJMTQSFJOTUBMMFE Optional accessories are available to meet the needs of particular installations. 5IF.FODMPTVSFQSPWJEFTUISFFSPXTGPSNPVOUJOH%*/NPVOUFE$#VTVOJUT&BDI SPXIBTUIFDBQBDJUZUPIPMEPOF.VOJUPOF.VOJUXJUIPOF.VOJUPSUISFF. units. 4DIOFJEFS&MFDUSJD.&ODMPTVSFTBSFTQFDJýDBMMZEFTJHOFEGPSDPOWFOUJPOBMJOTUBMMBUJPO OFBSUIFNBJOCSFBLFSQBOFM5IFZQSPWJEFBTJNQMFNFBOTPGJOTUBMMJOH$#VT %*/NPVOUFEVOJUTXJUIBMMPGUIFOFDFTTBSZXJSJOHOFVUSBMCBSCBSSJFSTBOEPUIFS components included. Once installed, the enclosure system allows for easy system maintenance with the units accessible. "EEJUJPOBMCBSSJFSTQSPWJEFHSFBUFSþFYJCJMJUZUPNFFUSFRVJSFNFOUTPG/&$"SUJDMFGPS separation of class 2 circuits. .&ODMPTVSF Technical Information Product Features t/&."®FODMPTVSFTVJUBCMFGPSþVTIPS surface mounting t8FMEFETIFFUTUFFMXJUILOPDLPVUT t8IJUFPSHSBZCBLFEFOBNFMQBJOU electrodeposited over cleaned, phosphatized steel t5SJQMFMFBEDPWFSTDSFXTGPSGBTU installation of cover t5ISFF%*/SBJMTFBDITVJUBCMFGPSNPVOUJOH $#VT%*/VOJUTJOPOFPGUIFGPMMPXJOH DPOýHVSBUJPOT 0OF.VOJU 0OF.NPEVMFXJUIPOF .VOJU 5ISFF.VOJUT t6--JTUFE 36M Enclosure 5ZQF /&." %*/.PEVMF$BQBDJUZ 5ISFF%*/SBJMTFBDIXJUIUIFDBQBDJUZGPSPOF. POF.XJUIPOF.PSUISFF.$#VT%*/VOJUT %JNFOTJPOTXJUI$PWFS JO- YJO8 YJO% <NN- YNN8 YNN% > 4UBOEBSE 6-4UBOEBSE&ODMPTVSFTGPSFMFDUSJDBMFRVJQNFOU .PEVMF.PVOUJOH %*/SBJM 5PUBM8FJHIU MCLH *For Diagram see technical section page 106 Catalog Number Accessories 4-$$ &ODMPTVSF$BCJOFUJO 1,(5" /FVUSBMCBSUFSNJOBM 4-$.'( .PVOUJOHQBOXJUIHSBZþVTINPVOUDPWFS 1,(5"# /FVUSBMJOTVMBUPSLJU 4-$.4( .PVOUJOHQBOXJUIHSBZTVSGBDFNPVOUDPWFS 1,(5" (SPVOECBSUFSNJOBM 4-$.'8 .PVOUJOHQBOXJUIXIJUFþ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escription C-BUSTM LIGHTING CONTROL + ENCLOSURES C-BusTM 36MS Enclosures 5IF$#VT5.&ODMPTVSFTQSPWJEFBNVMUJQVSQPTFNFBOTGPSIPVTJOHWBSJPVT$#VT %*/NPVOUFEEFWJDFT4VJUBCMFGPSþVTIPSTVSGBDFNPVOUJOHUIFFODMPTVSFDPOTJTUTPGB NPVOUJOHQBOBTTFNCMZBOEBDPWFSBTTFNCMZ5IFDBCJOFUDBOCFPSEFSFETFQBSBUFMZ allowing for its installation with the rough-in of field wiring. Optional accessories are available to meet the needs of particular installations. 5IF.4FODMPTVSFQSPWJEFTUISFFSPXTGPSNPVOUJOH%*/NPVOUFE$#VTVOJUT&BDI SPXIBTUIFDBQBDJUZUPIPMEPOF.VOJUPOF.VOJUXJUIPOF.VOJUPSUISFF. units. .4&ODMPTVSFTBSFTQFDJýDBMMZEFTJHOFEGPSDPOWFOUJPOBMJOTUBMMBUJPOOFBSUIFNBJO CSFBLFSQBOFM5IFZQSPWJEFBTJNQMFNFBOTPGJOTUBMMJOH%*/NPVOUFEVOJUTXJUIBMMPG the necessary wiring, neutral bars, ground bars and other components included. Once JOTUBMMFEUIFFODMPTVSFTZTUFNBMMPXTGPSFBTZTZTUFNNBJOUFOBODFXJUIUIF$#VTVOJUT accessible. .4&ODMPTVSF Technical Information Product Features t/&."®FODMPTVSFTVJUBCMFGPSþVTIPS surface mounting t8FMEFETIFFUTUFFMXJUILOPDLPVUT t8IJUFPSHSBZCBLFEFOBNFMQBJOU electrodeposited over cleaned, phosphatized steel t5SJQMFMFBEDPWFSTDSFXTGPSGBTUJOTUBMMBUJPO of cover t5ISFF %*/SBJMTFBDITVJUBCMFGPSNPVOUJOH $#VT%*/VOJUTJOPOFPGUIFGPMMPXJOH DPOýHVSBUJPOT 0OF .VOJU 0OF .NPEVMFXJUIPOF .VOJU 5ISFF .VOJUT 36M Enclosure 5ZQF /&." %*/.PEVMF$BQBDJUZ 5ISFF%*/SBJMTFBDIXJUIUIFDBQBDJUZGPSPOF. POF.XJUIPOF.PSUISFF.$#VT%*/VOJUT %JNFOTJPOTXJUI$PWFS JO- YJO8 YJO% <NN- YNN8 YNN% > 4UBOEBSE 6-4UBOEBSE&ODMPTVSFTGPSFMFDUSJDBMFRVJQNFOU .PEVMF.PVOUJOH %*/SBJM 5PUBM8FJHIU MCLH *For Diagram see technical section page 107 Catalog Number Description Accessories 4-$4$ &ODMPTVSF$BCJOFU 1,(5" 4-$.4'( 'MVTI.PVOU(SBZ 1,(5"# Neutral Isolator Kit 4-$.44( 4VSGBDF.PVOU(SBZ 4-$$4' Filler Plate 4-$.4'8 'MVTI.PVOU8IJUF 4-$3&$ %VBM3FDFQUBDMF#SBDLFU (SOE/FVUSBM 68 C-BUSTM LIGHTING CONTROL + ENCLOSURES C-BusTM 60M Enclosures 5IF$#VT5.&ODMPTVSFTQSPWJEFBNVMUJQVSQPTFNFBOTGPSIPVTJOHWBSJPVT$#VT %*/NPVOUFEEFWJDFT4VJUBCMFGPSþVTIPSTVSGBDFNPVOUJOHUIFFODMPTVSFDPOTJTUTPGB DBCJOFUBNPVOUJOHQBOBTTFNCMZBOEBDPWFSBTTFNCMZ5IFDBCJOFUDBOCFPSEFSFE separately, allowing for its installation with the rough-in of field wiring. Options are available to meet the needs of particular installations. 5IF.FODMPTVSFQSPWJEFTýWFSPXTGPSNPVOUJOH%*/NPVOUFE$#VTVOJUT&BDISPX IBTUIFDBQBDJUZUPIPMEPOF.VOJUPOF.VOJUXJUIPOF.VOJUPSUISFF.VOJUT 4DIOFJEFS&MFDUSJD.&ODMPTVSFTBSFTQFDJýDBMMZEFTJHOFEGPSDPOWFOUJPOBMJOTUBMMBUJPO OFBSUIFNBJOCSFBLFSQBOFM5IFZQSPWJEFBTJNQMFNFBOTPGJOTUBMMJOH%*/NPVOUFEVOJUT with all of the necessary wiring, neutral bar, barriers and other components included. 0ODFJOTUBMMFEUIFFODMPTVSFTZTUFNBMMPXTGPSFBTZTZTUFNNBJOUFOBODFXJUIUIF$#VT units accessible. .&ODMPTVSF Product Features Technical Information t/&."5ZQFFODMPTVSFTVJUBCMFGPSþVTIPS surface mounting t8FMEFETIFFUTUFFMXJUILOPDLPVUT t"/4*(SBZCBLFEFOBNFMQBJOU electrodeposited over cleaned, phosphatized steel t5SJQMFMFBEDPWFSTDSFXTGPSGBTUJOTUBMMBUJPO of cover t6-MJTUFE7SBUFE$MBTTCBSSJFS included t QSFJOTUBMMFEQPTJUJPOHSPVOECBSTBOE (5) 12 position isolated neutral assemblies included t'JWF%*/SBJMTFBDITVJUBCMFGPSNPVOUJOH $#VT%*/VOJUTJOPOFPGUIFGPMMPXJOH DPOýHVSBUJPOT 0OF.VOJU 0OF.VOJUXJUIPOF .VOJU 5ISFF.VOJUT t6--JTUFE 60M Enclosure 5ZQF %*/.PEVMF$BQBDJUZ /&."5ZQF 'JWF%*/SBJMTFBDIXJUIUIFDBQBDJUZGPS POF.POF.XJUIPOF.PSUISFF.$#VT%*/VOJUT %JNFOTJPOTXJUI JO- YJO8 YJO% $PWFSþVTINPVOU <NN- YNN8 YNN% > %JNFOTJPOTXJUI JO- YJO8 YJO% $PWFSTVSGBDFNPVOU <NN- YNN8 YNN% > %JNFOTJPOTPG JO- YJO8 YJO% &ODMPTVSF$BCJOFU <NN- YNN8 YNN% > 4UBOEBSE 6-4UBOEBSE&ODMPTVSFTGPSFMFDUSJDBMFRVJQNFOU .PEVMF.PVOUJOH %*/SBJM 5PUBM8FJHIU MCLH *For Diagram see technical section page 107 Catalog Number 69 Description Accessories Description 4-$$ &ODMPTVSF$BCJOFUJO 4%."$ 5XPEVQMFYQPXFSSFDFQUBDMFT 4-$.'( .PVOUJOHQBOXJUIHSBZþVTINPVOUDPWFS 1,'- %PPSMBUDIMPDLJOH 4-$.4( .PVOUJOHQBOXJUIHSBZTVSGBDFNPVOUDPWFS 4-$$4''JMMFSQMBUF. 4-$.'8 .PVOUJOHQBOXJUIXIJUFþVTINPVOUDPWFS C-BUSTM LIGHTING CONTROL + TECHNICAL SECTION NeoTM Keypad - Specifying Colors When Ordering Keypad Assemblies Order numbers for the Neo Keypad assemblies indicate the number of buttons EFTJSFEPOUIFLFZQBEBOEUIFDPMPSPGFBDIDVTUPNJ[BCMFDPNQPOFOUJOOFS surround, outer surround, and button cover). $PMPSOVNCFSTBSFUBLFOGSPNUIFi/FP$PMPSTwUBCMFBOENVTUCFHJWFOJOUIF GPMMPXJOHPSEFSPVUFSTVSSPVOEJOOFSTVSSPVOEBOECVUUPODPWFST 'PSFYBNQMFJOUIFEJBHSBNCFMPX4-$/-SFQSFTFOUTBOPSEFSGPSB/FP ,FZQBEXJUIFJHIUCVUUPOTBXIJUF PVUFSTVSSPVOEBCSVTIFEBMVNJOVN inner surround, and white (#2) button covers. Keypad Assemblies Standard 'PSFBTZPSEFSJOHUIFSFBSFTUBOEBSELFZQBEDPMPSTBWBJMBCMF 8IJUF4-$ /-8& $SFBN4-$ /-$. #SVTIFE"MVNJOVNX4MBUF4-$ /-(# ( ) - designates space for button configuration *MMVTUSBUJPOTIPXT*OOFS4VSSPVOE" 0VUFS4VSSPVOE# BOE#VUUPO$PWFST$ 4-$ /-8& Name 4-$ /-$. Color Number Slate 1 White 2 Cream 3 Soft Gray 4 Desert Sand 5 Black 6 Brown 7 Brushed Aluminum* 8 Gold* 9 4-$ /-(# Color *Only the inner surround is available in Brushed Aluminum and Gold 70 C-BUSTM LIGHTING CONTROL + TECHNICAL SECTION Neo™ Keypads 3.0 in. 76 mm .63 in. 16 mm .24 in. 6 mm 4.57 in. 116 mm 2.64 in. 67 mm 2.05 in. 52 mm 'SPOUWJFXPGLFZQBEJODMVEJOHFYUFSOBMIFJHIU 4JEFWJFXPGLFZQBEJODMVEJOHIFJHIUBOE #PUUPNWJFXPGLFZQBEJODMVEJOHNFBTVSFNFOUT and width measurements of case depth requirements for insertion into wall for width of unit and depth case extends from wall SaturnTM Keypads 3.0 in. 76 mm 0.51 in. 13 mm 2.6 in. 66 mm 4.57 in. 116 mm 2.05 in. 52 mm 2.7 in. 69 mm 0.6 in. 15 mm 'SPOUWJFXPGLFZQBEJODMVEJOHFYUFSOBM 4JEFWJFXPGLFZQBEJODMVEJOHIFJHIUBOEEFQUI height and width measurements of case requirements for insertion into wall 5PQWJFXPGLFZQBETIPXJOHXJEUI Neo™ Keypads with Dynamic Labeling Technology™ 3.0 in. 76 mm 4.57 in. 116 mm 71 0.51 in. 13 mm 0.71 in. 18 mm 'SPOUWJFXPGLFZQBEJODMVEJOHFYUFSOBM 5PQTJEFWJFXPGUIF/FP%-5LFZQBEJMMVTUSBUFTUIF height and width measurements of case depth the case extends into and out of a wall C-BUSTM LIGHTING CONTROL + TECHNICAL SECTION Saturn™ Keypads with Dynamic Labelling Technology™ 3.0 in. 76 mm 4.57 in. 116 mm .43 in. 10.8 mm 1.13 in. 28.8 mm 'SPOUBOEUPQTJEFWJFXTPGUIF4BUVSO%-5LFZQBEJMMVTUSBUF its length and width and the depth the case extends into and out of a wall Neo™ Style Decorator Keypads 0.63 in. 16 mm 3.0 in. 76 mm 1.69 in. 43 mm 2.76 in. 70 mm 4.57 in. 116 mm 0.28 in. 7 mm 'SPOUWJFXPGLFZQBEJODMVEJOHFYUFSOBMIFJHIU 4JEFWJFXPGLFZQBEJODMVEJOHIFJHIUBOE 5PQWJFXPGLFZQBEJODMVEJOH and width measurements of Faceplate depth requirements for insertion into wall depth of face plate Saturn™ Style Decorator Keypads .35 in. 9 mm 2.99 in. 2.99 in. 0.35 in. 9 mm 76 76 mm mm 2.76 in. 2.76 in. 70 70 mm mm 4.57 in. 4.57 in. 116 mm 116 mm 1.65 in. 1.65 in. 42 mm 42 mm 2.87 in. 2.87 in. 73 mm 73 mm 0.71 in. 18 mm .71 in. 'SPOUWJFXPGLFZQBEJODMVEJOHFYUFSOBMIFJHIU 18 mm 4JEFWJFXPGLFZQBEJODMVEJOHIFJHIUBOEEFQUI and width measurements of face plate requirements for insertion into wall 5PQWJFXPGLFZQBETIPXJOHXJEUI 72 C-BUSTM LIGHTING CONTROL + TECHNICAL SECTION Mark II Touch Screen 0.75 in. 19 mm 4.53 in. 115 mm 0.75 in. 19 mm 5.98 in. 152 mm 'SPOUWJFXPG.BSL**5PVDI4DSFFO 4JEFWJFXPG.BSL**5PVDI Screen Mark II Desktop Touch Screen 3.75 in. 95 mm 7.5 in. 191 mm Color Touch Screen 0.9 in. (23.5 mm) 2.2 in. (54 mm) LQPP 6.9 in. 173 mm 9.8 in. 246 mm 2.9 in. (72.5 mm) LQPP 'SPOUWJFXPG$PMPS5PVDI4DSFFO 73 4JEFWJFXPG$PMPS5PVDI4DSFFO C-BUSTM LIGHTING CONTROL + TECHNICAL SECTION Ethernet Network Interface 2.83 in. 72 mm 2.56 in. 65 mm 3.35 in. 85 mm 7JFXPGUIF&UIFSOFU/FUXPSL*OUFSGBDFTIPXJOHXJEUI 7JFXPGUIF&UIFSOFU/FUXPSL*OUFSGBDFTIPXJOHIFJHIUBOEEFQUI PC Interface 2.84 in. 72 mm 2.56 in. 65 mm 3.35 in. 85 mm 'SPOUWJFXPGUIF1$*OUFSGBDFTIPXJOHXJEUI 4JEFWJFXPGUIF1$*OUFSGBDFTIPXJOHIFJHIUBOEEFQUI USB Interface 2.84 in. 72 mm 2.60 in. 66 mm 3.35 in. 85 mm 'SPOUWJFXPGUIF1$*OUFSGBDFTIPXJOHXJEUI 4JEFWJFXPGUIF1$*OUFSGBDFTIPXJOHIFJHIUBOEEFQUI 74 C-BUSTM LIGHTING CONTROL + TECHNICAL SECTION Network Bridge 2.83 in. 72 mm 2.56 in. 65 mm 3.35 in. 85 mm 4JEFWJFXPG/FUXPSL#SJEHFTIPXJOHIFJHIUBOEEFQUI 'SPOUWJFXPGUIF/FUXPSL#SJEHFTIPXJOHXJEUI Power Supply 2.83 in. 72 mm 2.56 in. 65 mm 3.35 in. 85 mm Front view of a Power Supply showing width Side view of a Power Supply showing depth and height Pascal Automation Controller 2.83 in. 72 mm 2.48 in. 63 mm 3.62 in. 92 mm 'SPOUWJFXPGUIF1BTDBM"VUPNBUJPO$POUSPMMFS 75 4JEFWJFXPGUIF1BTDBM"VUPNBUJPO$POUSPMMFS C-BUSTM LIGHTING CONTROL + TECHNICAL SECTION Telephone Interface Unit 1.18 in. 30 mm 5.77 in. 146.5 mm 5.71 in. 145 mm TELEPHONE INTERFACE 'SPOUWJFXPG5FMFQIPOF*OUFSGBDF6OJU 4JEFWJFXPG5FMFQIPOF*OUFSGBDF6OJU Bus Coupler General Input Unit 0.71 in. LQ 18 mm PP 5.7 in. 144 mm General Input 5PQWJFXPG(FOFSBM*OQVU6OJU 2.6 in. 65 mm 4JEFWJFXPGUIF'PVS$IBOOFM#VT$PVQMFS 2.2 in. 2.2 in. 55 mm 55 mm 3.4 in. 85 mm 1.9 in. 1.9 in. 49 mm mm 49 4JEFWJFXPG(FOFSBM*OQVU6OJU 5104BCL Bus Coupler 1 2 3 4 1C 2C 3 C 4 C 5PQWJFXPG'PVS$IBOOFM#VT$PVQMFS 76 C-BUSTM LIGHTING CONTROL + TECHNICAL SECTION Four-Channel Auxiliary Input Unit 2.8 in. 72 mm 2.6 in. 65 mm 3.4 in. 85 mm 4JEFWJFXPG'PVS$IBOOFM"VYJMJBSZ*OQVU6OJU 5PQWJFXPG'PVS$IBOOFM"VYJMJBSZ*OQVU6OJU Indoor PIR Occupancy Sensor 8 ft 2.4 m 20 ft 6m 3.9 in. 100 mm 28 ft 8.5 m 20 ft 6m 2.2 in. 57 mm 28 ft 8.5 m ft 28 ft 8.5 m 8.5 m Field of view from top of indoor occupancy sensor Field of view from side of indoor occupancy sensor Front view of indoor occupancy sensor 360° PIR Occupancy and Multi-Sensor 2.83 in. 72 mm 26 ft 8m .59 in. 15 mm 3.46 in. 88 mm 1.85 in. 47 mm 8 ft 2.4 m 1.97 in. 50 mm 13 ft 4m 77 7 ft 2m 0 7 ft 2m 13 ft 4m 'JFMEPGWJFXGSPNUPQBOETJEFGPS1*30DDVQBODZ 4FOTPSNPVOUFEGUBCPWFþPPS 'SPOUWJFXPG$#VT¡ PIR Occupancy Sensor 4JEFWJFXPG$#VT¡ PIR Occupancy Sensor C-BUSTM LIGHTING CONTROL Outdoor Motion Sensor + TECHNICAL SECTION 5.5 in. 140 mm 8 ft 2.4 m 5° 4.5 in. 114 mm 30° 2.9 in. 74 mm 'JFMEPGWJFXGSPNUPQPG0VUEPPS.PUJPO4FOTPS 'JFMEPGWJFXGSPNTJEFPG0VUEPPS.PUJPO4FOTPS 4JEFWJFXPG0VUEPPS.PUJPO4FOTPS Light-Level Sensor 0.52 in. 13 mm 2.99 in. 76 mm 0.49 in. 12.5 mm 4.57 in. 116 mm 2.83 in. 72 mm 'SPOUWJFXPG-JHIU-FWFM4FOTPS 1.93 in. 49 mm 4JEFWJFXPG-JHIU-FWFM4FOTPS 5PQWJFXPGMJHIUMFWFMTFOTPS Outdoor Light-Level Sensor 4 in. 102 mm 4 in. 102 mm 2.5 in. 65 mm 7JFXJODMVEJOHIFJHIUXJEUIBOEEFQUIEJNFOTJPOT 78 C-BUSTM LIGHTING CONTROL + TECHNICAL SECTION Professional Series Dimmer 7.5 in. 190 mm 8 in. 202 mm 9 in. 230 mm 7.7 in. 195 mm 3 in. 75 mm 32:(5 1(7:25. 0.4 in. 10 mm Front view including mounting centers 5PQWJFX Side view Phase Angle Dimmer Unit 2.6 in. 65 mm 8.5 in. 215 mm 3.4 in. 85 mm 'SPOUWJFXPGUIF1IBTF"OHMF%JNNFS6OJU 4JEFWJFXPGUIF1IBTF"OHMF%JNNFS6OJU 2 Channel DALI Gateway 2.83 2.83 in. in. 72 72 mmmm 2.6 in. LQ 65 mm PP DALI 1 DALI 2 Unit/ Comms 3.4 in. LQ 85 mm PP C-Bus DALI Gateway C-Bus CONNECTIONS 'SPOUWJFXPG%"-*(BUFXBZ 79 4JEFWJFXPG%"-*(BUFXBZ C-BUSTM LIGHTING CONTROL + TECHNICAL SECTION 4 Channel 0-10V Fluorescent Ballast Dimmer 2.83 in. 72 mm 2.56 in. 65 mm 3.35 in. 85 mm 'SPOUWJFXPGUIF7'MVPSFTDFOU#BMMBTU%JNNFS 4JEFWJFXPGUIF7'MVPSFTDFOU#BMMBTU%JNNFS 10 Amp Relay Unit 5.67 in. 144 mm 2.56 in. 65 mm 3.35 in. 85 mm 'SPOUWJFXPGB$#VT$IBOOFM"NQ Relay without power supply 4JEFWJFXPGB$#VT$IBOOFM"NQ3FMBZ 20 Amp Relay Units 2.56 in. 65 mm 8.46 in. 215 mm 3.35 in. 85 mm 'SPOUWJFXPGB$#VT$IBOOFM"NQ3FMBZXJUI1PXFS4VQQMZ 4JEFWJFXPGB$#VT$IBOOFM"NQ3FMBZ 80 + C-BUSTM LIGHTING CONTROL TECHNICAL SECTION Changeover Relay Units 5.67 in. 144 mm N L C 2 3 NO NC 1 USE COPPER WIRE ONLY 1 2.60 in. 66 mm C NO NC 2 4 Unit 3.35 in. 85 mm C-Bus Changeover Relay 3 C-Bus CONNECTIONS NC NO 4 C NC NO C 'SPOUWJFXPGB$#VT$IBOHFPWFS3FMBZ 4JEFWJFXPGB$#VT$IBOHFPWFS3FMBZ Low Voltage Relay 8 Channel 3.15 in. (80 mm) 8.66 in. (220 mm) 1.50 in. (38 mm) 8M Enclosure 8.9 in. LQ PP 226 mm 3.8 in. LQ 97 mm PP LQ 12.57 in. PP 319 mm 'SPOUWJFXPG.&ODMPTVSFCPYTIPXJOHIFJHIUBOEXJEUI 81 4JEFWJFXPG.&ODMPTVSFCPYTIPXJOHEFQUI C-BUSTM LIGHTING CONTROL 12M Enclosure + TECHNICAL SECTION 4.0 in. 102 mm 12.78 in. 325 mm 9.09 in. 231 mm 4JEFWJFXPG.&ODMPTVSFCPYTIPXJOHEFQUI 'SPOUWJFXPG.&ODMPTVSFCPYTIPXJOHIFJHIUBOEXJEUI 24M Enclosure 4.0 in. 102 mm 14.50 in. 368 mm 14.94 in. 379 mm 4JEFWJFXPG.&ODMPTVSFCPYTIPXJOHEFQUI 'SPOUWJFXPG.&ODMPTVSFCPYTIPXJOHIFJHIUBOEXJEUI 36M Enclosure 15.4 in. 392 mm 3.9 in. 99 mm B,C,D,E B,C,D,E C,D,E,F,G D,E,F,G A A,B C,D,E,F D,E,F,G .,OPDLPVUT 4ZNCPM$POEVJU4J[F4ZNCPM$POEVJU4J[F " ½ E B ¾ F $ 1 ( 1½ B,C A,B % 2 2½ 1¼ A 40.6 in. 1031 mm A,B,C,D B,C,D,E C,D,E,F 'SPOUBOETJEFWJFXþVTINPVOU ,OPDLPVUT 82 C-BUSTM LIGHTING CONTROL + TECHNICAL SECTION 36MS Enclosure 3.81 in. (97 mm) 15.44 in. (392 mm) 14.24 in. (362 mm) 22.12 in. (562 mm) 20.93 in. (532mm) .4,OPDLPVUT 4ZNCPM$POEVJU4J[F4ZNCPM$POEVJU4J[F %JNFOTJPOTGPSUIF.4 &ODMPTVSF4VSGBDF.PVOUFE %JNFOTJPOTGPSUIF.4 &ODMPTVSF'MVTI.PVOUFE " ½ E B ¾ F $ 1 ( % 1 ¼ ) 1½ 2 2½ 60M Enclosure 15.4 in. 392 mm 3.9 in. 99 mm B,C,D,E B,C,D,E C,D,E,F,G D,E,F,G A A,B C,D,E,F D,E,F,G .,OPDLPVUT Symbol B,C A,B A A,B,C,D B,C,D,E C,D,E,F 'SPOUBOETJEFWJFXþVTINPVOU 83 ,OPDLPVUT Symbol Conduit Size ½ E B ¾ F $ 1 ( % 40.6 in. 1031 mm Conduit Size " 1¼ 1½ 2 2½ 84 Wiser Home Control 85 Wiser by name, wiser by nature Your household appliances, your lights, your computers, your mobile phones all used to XPSLJOEFQFOEFOUMZBOEXFSFDPOUSPMMFE independently. 8JTFSIPNFDPOUSPMGSPN4DIOFJEFS&MFDUSJD NBLFTUFDIOPMPHZJOZPVSIPNFFBTZCZ providing seamless control of music, home DJOFNBBJSDPOEJUJPOJOHMJHIUJOHTQSJOLMFS systems, curtains and shutters, security systems... you name it. :PVHFUUIFTBNFMPPLBOEGFFMGPSFWFSZUIJOH BOZUJNFBOZXIFSFGSPNBMJHIUTXJUDIB touch screen, a home computer, or even from ZPVSþBUTDSFFO57BTZPVSFBCPVUUPXBUDI a movie. You can turn on your air-conditioner from your mobile phone on the way home, or DIFDLUIBUFWFSZUIJOHJTUVSOFEPGGPWFSUIF *OUFSOFUXIFOZPVHFUUPXPSL 4PUBLFDPOUSPMBOEFOKPZFWFSZNJOVUFPGZPVS MJGFCZTJNQMZCFDPNJOH8JTFS 86 + WISER HOME CONTROL WISER HOME CONTROLLERS Wiser Home Controller™ 5IF8JTFS)PNF$POUSPMMFSQSPWJEFTBOFBTZUPVTFHSBQIJDBMVTFSJOUFSGBDF(6* UP BDDFTTBIPNF$#VTOFUXPSLBOEBMMPGZPVSFMFDUSJDBMNVMUJNFEJBBOE UFMFDPNNVOJDBUJPOOFFET5IJTTBNF(6*DBOCFJOTUBMMFEBDSPTTNVMUJQMFDPOUSPM EFWJDFTTVDIBTNPCJMFQIPOFT57TXJUI.JDSPTPGU¥8JOEPXT®.FEJB$FOUFS QFSTPOBMDPNQVUFSTBOEXFCUBCMFUTJOBEEJUJPOUPUIF$#VTSBOHFPGUPVDITDSFFOT BOELFZQBET/PNBUUFSXIFSFZPVBSFUIF8JTFS)PNF$POUSPMMFSMFUTZPVNPOJUPSBOE control your home environment locally or remotely over the Internet. 8JTFS)PNF$POUSPMMFS Technical Information 1PXFS4PVSDF )PNF$POUSPMMFSTSPVUFS"$QPXFSQBDL *OMJOF$#VT/FUXPSL*OUFSGBDF o"$QPXFSQBDLUISPVHICVTCBSGPS&UIFSOFU o$#VTTJEFJTQPXFSFECZUIF$#VTOFUXPSL .PVOUJOH-PDBUJPO Product Features 8BMMNPVOUFEXJUIUXPLFZIPMFPQFOJOHT .VTUCFJOTUBMMFEJOEPPST .JOJNVN%JTUBODF5P0QFSBUPS ¡'UP¡'¡$UP¡$ 3)OPODPOEFOTJOH .PVOUJOH4DSFX4QBDJOH JONN CFUXFFODFOUSFT 0QFSBUJOH"NCJFOU5FNQFSBUVSF o¡'¡$ 0QFSBUJOH3FMBUJWF)VNJEJUZ UPOPODPOEFOTJOH 5ZQFT0G&MFDUSJDBM$POOFDUJPO 4VJUBCMFGPSDPQQFSPSBMVNJOJVN DPOEVDUPST %JTDPOOFDUBCMF%$QPXFSTVQQMZKBDLPOUIFCVTCBS YJOYNN DFOUFSQPTJUJWF %JTDPOOFDUBCMF8"/DPOOFDUPSPOCVTCBSY3+QMVH %JTDPOOFDUBCMF-"/DPOOFDUPSTPOSPVUFSY3+QMVH 'JYFEBVY$#VT UFSNJOBMGPSYNNGPSUXJTUFEQBJST with strain relief post &UIFSOFU8"/1SPUPDPM 5$1*1 .JDSPTPGU® Internet Explorer®.P[JMMB® Firefox® 3FDPNNFOEFE*OUFSOFU#SPXTFST $4"4QFD4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDFGPS)PNFPS0GýDF6TF 6-&OFSHZ.BOBHFNFOU&RVJQNFOU Standards *For Diagram see technical section page 88 87 Catalog Number Description 8)$ 8JTFS)PNF$POUSPMMFS t&UIFSOFUBOE8J'JCBTFEDPOUSPMMFSGPSZPVS $#VTTZTUFN t#VJMUJO&UIFSOFUSPVUFS t#VJMUJO8J'JBDDFTTQPJOU t4VQQPSUGPSMJHIUJOHBJSDPOEJUJPOJOH multi-room audio, alarms, cameras, and other equipment t&BTZUPVOEFSTUBOE8J[BSE t#VJMUJOTDFOFTDIFEVMJOHBOEMPHJD programming modules t&BTJMZQSPHSBNNBCMFGSPNPVUTJEFUIFIPNF building by installers t$PNNPOJOUVJUJWFJOUFSGBDFGPSBMMZPVS devices t3FDPHOJ[FBOEVUJMJ[F$#VT5"( EFTDSJQUJPOT-PDBUJPOTBOE'VODUJPO (SPVQT t$POýHVSFBOEDPNNJTTJPOBTQFDUTPG lighting, security, and environmental FRVJQNFOUVTJOH$#VT5PPMLJUBOE1*$&% software. t$POUSPMWJBZPVSNPCJMFQIPOFPSPUIFSXFC enabled devices t$POUSPMWJBFNBJMNFTTBHFT t%JTQMBZTVQUPUIFNJOVUFOFXTXFBUIFS and more WISER HOME CONTROL + TECHNICAL SECTION Wiser Home Controller™ 2.75 in. 2.75 in. 70 mm 70 mm 2.9 in. 2.9 in. 74 74mm mm 3.75 in. 3.75 in. 95.5 mm 95.5 mm 0.9 in. 0.9 in. 23 mm 23 mm 6.25 in. 6.25 in. 159 mm 159 mm 3.3 in.in. 3.3 85 mm 85 mm 0.2 0.2 in. in. 66 mm mm 0.9 in. 0.9 in. 25 mm 25 mm 2.4 2.4 in. in. 1.4 1.4 in.in. 35 35mm mm 60 mm mm 60 3.75 in. 3.75 in. 95.5 mm 95.5 mm 'SPOUWJFXPG8JTFS)PNF$POUSPMMFS 88 C-BusTM Multi-Room Audio, Remote Controls and IR Accessories 89 Introduction to C-BusTM Multi-Room Audio, Remote Controls and IR Accessories &YUFOEUIFDBQBCJMJUJFTPGB$#VTTZTUFNCZ JODPSQPSBUJOHBXBSEXJOOJOH$#VTNVMUJSPPN BVEJP.VMUJSPPNBVEJPBVHNFOUTB$#VT lighting control system, providing high quality sound throughout a home or business. $#VTNVMUJSPPNBVEJPSFBEJMZJOUFHSBUFTXJUI PUIFS$#VTDPOUSPMTQSPWJEJOHBTJOHMFTPVSDF GPSBVEJPBOEMJHIUJOHGSPNBTJOHMFLFZQBEPS touch screen. Sound is distributed throughout the home through the matrix switcher and routed to local amplifiers. "UZQJDBM$#VT.VMUJSPPN"VEJPTZTUFN distributes up to four analog audio inputs, five if an audio distribution unit is used, and POFPQUJDBMJOQVU5IFTFJOQVUTBSFEJTUSJCVUFE up to eight zones, each consisting of one or more amplifier. "EEJUJPOBMMZFBDIBNQMJýFSJTDBQBCMFPG accepting a local analog audio input, providing up to seven stereo audio sources for each amplifier. 90 C-BUSTM AUDIO + MULTI-ROOM AUDIO C-BusTM Matrix Switcher 5IF$#VT5."VEJP.BUSJY4XJUDIFSQSPWJEFTBSFWPMVUJPOBSZNFBOTGPSEJTUSJCVUJOHBVEJP UISPVHIPVUBIPNF5IJT.BUSJY4XJUDIFSQSPWJEFTVQUPFJHIU[POFTPGBVEJPPVUQVU GSPNGPVSTPVSDFJOQVUT5IF$#VT .BUSJY4XJUDIFSBMMPXTZPVUPTFOETUSFBNJOHBVEJP QSPHSBNTUPUIFBVEJP[POFTGSPNBWBSJFUZPGTPVSDFTJODMVEJOHBMPDBMBSFBOFUXPSL -"/ PSB64#NFNPSZTUJDL.PEFM4-$& *OBEEJUJPOJUXJMMBMTPBMMPX DPOOFDUJPOPGBQPSUBCMFNVTJDQMBZFSEJSFDUMZUPUIF.BUSJY4XJUDIFSTGSPOUBVEJPQBOFM "VEJPTPVSDFTDBOCFTFMFDUFEGSPNUIFGSPOUQBOFMPSCZBOZ$#VT5. input device such BTUPVDITDSFFOTPSLFZQBET5IFNBUSJYTXJUDIFSJTJEFBMMZTVJUFEGPSNVMUJSPPNBVEJP BOETUSVDUVSFEXJSJOHTZTUFNT,FZQBETBOEPUIFS$#VT5. devices connect to the NBUSJYTXJUDIFSWJB$"5NPEVMBSKBDLT0VUQVUTUPSFNPUFBOEEFTLUPQBNQMJýFSTBSF made with low voltage wiring. In addition to the six source inputs, two mono broadcast annunciation inputs are provided for connection to intercoms or other systems. Broadcast annunciation input can be given priority over other source inputs and feature fully adjustment volume and over-stepping mute features Product Features Technical Information 4VQQMZ7PMUBHF 7"$ .BJOT'SFRVFODZ3BOHF UP)[BOEUP)[ $#VT"$*OQVU*NQFEBODF LPIN!L)[ 1PXFS$POTVNQUJPO 8NBYJNVN $#VT/FUXPSL7PMUBHF $#VT4JOL$VSSFOU UP7ED N"UIFNBUSJYTXJUDIFSEPFTOPUTVQQMZDVSSFOUUPUIFOFUXPSL /FUXPSL$MPDL#VSEFO Software selectable Source input signal level 7QQNBYJNVNLPIN "%$POWFSTJPO #JU1$. 0QFSBUJOH5FNQFSBUVSF UP¡$UP¡' 0QFSBUJOH)VNJEJUZ3BOHF UP3)OPODPOEFOTJOH 4UBOEBSET 6-"VEJP7JEFPBOE4JNJMBS&MFDUSPOJD"QQBSBUVT Safety Requirements System Audio Performance 'SFRVFODZ3FTQPOTF 5PUBM)BSNPOJD%JTUPSUJPO )[UPL)[E#E# L)[83.4JOUPLPIN L)[83.4JOUPPINT ECQFBLVOXFJHIUFE Signal to Noise Ratio "VEJP.BUSJY4XJUDIFS t4VJUBCMFGPS3BDL.PVOUXJUISBDL mount ears provided. t&BDINBUSJYTXJUDIFSDBOEJTUSJCVUFEJHJUBM BVEJPUPVQUP.3"BNQMJýFST:PVDBO JOTUBMMVQUPNBUSJYTXJUDIFSTPOB$#VT OFUXPSL t5IFNBUSJYTXJUDIFSDBOQSPWJEFQPXFSGPS UIFBUUBDIFEBNQMJýFSTWJBUIF%JHJUBM"VEJP cables. You can connect an external power supply to an amplifier to increase its audio power output. t5IFDIPJDFPGUIFBVEJPQSPHSBNGPSBOBNplifier can be made at the matrix switcher PSJOUIFBVEJP[POF:PVDBOVTF$#VT input devices to choose the source and to adjust volume, tone and muting. t5IF%VBM".'.UVOFSTJOTJEFUIFNBUSJY switcher can distribute preset station choices to any of the audio zones. t%JTUSJCVUFTTUSFBNJOHBVEJPGSPNTFWFSBM TPVSDFTVTJOHUIF$#VT3JQQMFTPGUXBSF BQQMJDBUJPOSVOOJOHPOBOFUXPSLFE1$ *For Diagram see technical section page 98 t:PVDBODPOOFDUVQUPTUFSFPBOBMPHVF line-level inputs to the matrix switcher. If you need to add another source input, you DBOJOTUBMMBO.3"%JTUSJCVUJPO6OJUBOE power supply. Distributed Intelligence t$PNQBUJCMFXJUI$#VTEFWJDFT 91 Catalog Number Description 4-$ .BUSJY4XJUDIFSXTUFSFPBOBMPHJOQVUTJOUFSOBM".'.UVOFST*3JOQVUBOEUBSHFUDPOOFDUJPOT6QUP.3";POFT 4-$& . BUSJY4XJUDIFSXTUFSFPBOBMPHJOQVUTJOUFSOBM".'.UVOFST*3JOQVUBOEUBSHFUDPOOFDUJPOT "VEJPTUSFBNJOHVTJOHB-"/PS64#TPVSDF6QUP.3";POFT C-BUSTM AUDIO + MULTI-ROOM AUDIO C-BusTM Multi-Room Amplifiers 5IF$#VT5..VMUJ3PPN"NQMJýFSTQSPWJEFFGýDJFOUIJHIýEFMJUZBVEJPUPJOEJWJEVBMSPPNT "WBJMBCMFJOFJUIFSEFTLUPQPSSFNPUFNPVOUWFSTJPOTUIFTFBNQMJýFSTBSFTQFDJýDBMMZ EFTJHOFEUPPQFSBUFPOUIF$#VTOFUXPSLBTBOFYUFOTJPOPGUIFMJHIUJOHDPOUSPMTZTUFN XJUIPVUUIJSEQBSUZHBUFXBZTPSDVTUPNJOUFHSBUJPO5IJTNFBOTUIFBCJMJUZUPDPOUSPM BNQMJýFSTXJUIUIFTBNFLFZQBEPSUPVDITDSFFOVTFEUPDPOUSPMMJHIUJOHMFWFMT %FTLUPQ"VEJP"NQMJýFS 8IFODPNCJOFEXJUIUIF$#VT.BUSJY4XJUDIFSUIFTFBNQMJýFSTEFMJWFSFYDFMMFOUTUFSFP TPVOEBU8BUUTXJUIPVUBTFQBSBUFQPXFSTVQQMZ8IFOGVSOJTIFEXJUIPQUJPOBMQPXFS TVQQMZUIFTFBNQMJýFSTQSPWJEF8BUUT$POOFDUJPOTBSFQSPWJEFEGPSVQUPUXPTFUTPG PINTQFBLFST #PUIEFTLUPQBOESFNPUFBNQMJýFSTQSPWJEFBMPDBMJOQVUDPOOFDUJPOGPSBUUBDIJOHUP$% PSNQQMBZFSTFUD*OBEEJUJPOUIFEFTLUPQBNQMJýFSXJMMBDDFQUSFNPUFDPNNBOETWJBJUT infrared receiver. Infrared remote included. Product Features Technical Information 4VQQMZ7PMUBHF RFNPUF.PVOUFE"VEJP"NQMJýFS 7EDQPXFSFECZ.BUSJY4XJUDIFSWJBEJHJUBMBVEJPDPOOFDUJPO BOEPS 7ED!"WJBFYUFSOBMTXJUDINPEFQPXFSTVQQMZ PS7BD!"WJBFYUFSOBMMJOFBSQPXFSTVQQMZ $#VT4VQQMZ7PMUBHF UP7ED!N" 1PXFS$POTVNQUJPO 8NBYJNVN /FUXPSL$MPDLBOE#VSEFO Software selectable "OBMPH*OQVU4JHOBM-FWFM (source inputs) 7QQNBYJNVNLû %"$POWFSTJPO #JU1$. .BYJNVN1PXFS0VUQVU 83.4JOUPû5)% )[UPL)[ 1 dB) Frequency Response 5PUBM)BSNPOJD%JTUPSUJPO VTJOHBOBMPHJOQVU L)[83.4JOUPPINT E#QFBLVOXFJHIUFE Signal to Noise Ratio 0QFSBUJOH %FTLUPQ"NQ¡'UP¡$ 5FNQFSBUVSF 3FNPUF"NQ¡'UP¡$ 0QFSBUJOH)VNJEJUZ3BOHF t8BUUEJHJUBMFGýDJFOUTUFSFPBNQMJýFS 8BUUTXIFODPOOFDUFEUPMPDBMQPXFSTVQQMZ (optional) t4VQFSRVJFUEFTJHO t0OCPBSEPINMPVETQFBLFSDPOOFDUJPOT t-PDBMTPVSDFJOQVU3$"KBDL t$#VTDPOOFDUJPODPOOFDUTXJUI$"5 cable) t7PMVNFDPOUSPMEFTLUPQNPEFM t0OCPBSE*3SFDFJWFSEFTLUPQNPEFM t4UFSFPIFBEQIPOFDPOOFDUJPOEFTLUPQ model) t*OGSBSFESFNPUFJODMVEFEEFTLUPQNPEFM only) Distributed Intelligence t$PNQBUJCMFXJUI$#VTEFWJDFT 3)OPODPOEFOTJOH 4UBOEBSET 6-"VEJP7JEFPBOE4JNJMBS&MFDUSPOJD"QQBSBUVT Safety Requirements System Audio Performance 1BSBNFUFS .BUSJY4XJUDIFS"NQMJýFS 'SFRVFODZ )[UPL)[ )[UPL)[ 3FTQPOTF E# E# 5PUBM)BSNPOJD%JTUPSUJPO 4JHOBMUP/PJTF3BUJP %JTUSJCVUJPO6OJU"NQMJýFS L)[83.4JOUPPINT E#QFBLVOXFJHIUFE *For Diagram see technical section page 115 Catalog Number Description 4-$% %FTLUPQ"NQMJýFS 4-$3 3FNPUF"NQMJýFS 4-$15 "VEJP"NQMJýFS1PXFS4VQQMZ 4-$.# 3FNPUF"NQMJýFS.PVOUJOH#SBDLFU 92 C-BUSTM AUDIO + MULTI-ROOM AUDIO C-BusTM Audio Distribution Unit 5IF$#VT5."VEJP%JTUSJCVUJPO6OJUJTBOPQUJPOBMEFWJDFUIBUDBOCFVTFEJO DPOKVODUJPOXJUIUIF$#VT.VMUJ3PPN"VEJP4ZTUFNUPGVSUIFSFOIBODF$#VTFOBCMFE audio product family. 5IF$#VT"VEJP%JTUSJCVUJPO6OJUEJTUSJCVUFTBTJOHMFEJHJUJ[FETUFSFPBVEJPJOQVUTPVSDF UPNVMUJQMFMPDBUJPOTWJBBNQMJýFSTXJSFEJOBQBSBMMFMGPSNBU'VODUJPOTTVDIBT7PMVNF #BTT5SFCMFBOE#BMBODFDBOCFBEKVTUFEGSPNB$#VTJOQVUEFWJDFBUBOZPGUIFBVEJP output locations. "VEJP%JTUSJCVUJPO6OJU 5IF$#VT"VEJP%JTUSJCVUJPO6OJUDPOWFSUTBTJOHMFBOBMPHTUFSFPBVEJPJOQVUUPBEJHJUBM BVEJPPVUQVU5IBUPVUQVUDBOUIFOCFDPOOFDUFEUPUIF.BUSJY4XJUDIFSBTBOBEEJUJPOBM JOQVUPSUPUIF$#VT%FTLUPQPS3FNPUF"NQMJýFSBTBTUBOEBMPOFDPOýHVSBUJPO Product Features Technical Information 4VQQMZ7PMUBHF 7EDQPXFSFECZ"NQMJýFSWJBEJHJUBMBVEJPDPOOFDUJPO PS 7ED!N"WJBFYUFSOBMQPXFSQBDL "OBMPH*OQVU 4JHOBM-FWFMBVEJPJOQVUT 7QQNBYJNVNLû )BSNPOJD%JTUPSUJPO õ 'SFRVFODZ3FTQPOTF )[UPL)[ %JNFOTJPOT8Y)Y% JOYJOYJONNYNNYNN IR Port Yes "%$POWFSTJPO t%JTUSJCVUFTBTJOHMFTUFSFPBVEJPTPVSDFUP $#VT"VEJP"NQMJýFSTWJBBEJHJUJ[FETJHOBM PWFS$BUDBCMF t%PFTOPUSFRVJSFBOZ$#VTQSPHSBNNJOH (hardware only) t0OFTUFSFPBOBMPHBVEJPTPVSDFJOQVU 93$" t0OFEJHJUBMBVEJPPVUQVU t0VUQVUDBOCFMPPQFECFUXFFO$#VT "VEJP"NQMJýFST t*3FNJUUFSQPSU CJU1$. 0QFSBUJOH5FNQFSBUVSF O'O$ 0QFSBUJOH)VNJEJUZ 3)OPODPOEFOTJOH 4UBOEBSE 6--JTUFE"VEJP7JEFPBOE4JNJMBS &MFDUSPOJD"QQBSBUVT4BGFUZ3FRVJSFNFOUT *For Diagram see technical section page 116 93 Catalog Number Description 4-$ "VEJP%JTUSJCVUJPO6OJU 4-$14 "NQ&YUFSOBM1PXFS4VQQMZPOMZOFFEFEJG"VEJPEJTUSJCVUJPOVOJUJTVTFEUPQSPWJEFBOBEEJUJPOBMEJHJUBMJOQVUGPSUIF.BUSJY4XJUDIFS C-BUSTM AUDIO + MULTI-ROOM AUDIO C-BusTM Audio Speakers 5IF$#VT5."VEJP4QFBLFSTBSFBWBJMBCMFBTJOEPPSPSPVUEPPSNPEFMTBOEBSFEFTJHOFE UPCFVTFEXJUIIPNFUIFBUFSNVMUJSPPNBOEPVUEPPSBVEJPBQQMJDBUJPOTUIBUXJMMBDDFQU 0INTQFBLFSTTVDIBTUIF4DIOFJEFS&MFDUSJD$#VT.VMUJ3PPN"VEJP.3" TZTUFN 5IFJOEPPSTQFBLFSTDPNFJOXBMMPSDFJMJOHNPVOUWFSTJPOTUIBUBSFJOTUBMMFEXJUIUIFGSPOU PGUIFTQFBLFSþVTIXJUIUIFNPVOUJOHTVSGBDF5IFJOEPPSPVUEPPSTQFBLFSTDBOCFQMBDFE POBTIFMGPSIVOHPOBTVSGBDFCZVTJOHUIFJODMVEFECSBDLFU Indoor Audio Speakers *OTUBMMBUJPO 4QFBLFS%JNFOTJPOT $FJMJOH.PVOUPS8BMM.PVOU $FJMJOH.PVOUJO%JB YJO% NNYNN 8BMM.PVOUJO) YJO8 YJO% NNYNNYNN 4QFBLFS%JBNFUFS $FJMJOH.PVOUJONN 8BMM.PVOUJONN 8FJHIU $FJMJOH.PVOUMC8BMM.PVOULH MCLH .BUFSJBM ,FWMBS®1PMZQSPQZMFOF *OEPPS4QFBLFST Operating Environment 5FNQFSBUVSF $FJMJOH.PVOU¡'¡'¡$¡$ 8BMM.PVOU¡'¡'¡$¡$ 3FMBUJWF)VNJEJUZ OPODPOEFOTJOH "VEJP1FSGPSNBODF 'SFRVFODZ3FTQPOTF $FJMJOH.PVOU)[L)[)[L)[ 1PXFS3BUJOH 8BMM.PVOU)[L)[)[L)[ *NQFEBODF 4FOTJUJWJUZ 83.4 0IN )[L)[)[L)[E# )[L)[E# )[L)[E# **Kevlar drivers have a fourth order 24/24 dB crossover for both tweeter and woofer *Polypropylene drivers have a second order 12/12 dB crossover for both tweeter and woofer Product Features Outdoor Audio Speakers Installation Indoor, outdoor, shelf 0WFSBMM%JNFOTJPOT JO) YJO8GSPOU YJO8SFBS YJO% <NN) YNN8G YNN8S YNN% > 4QFBLFS%JBNFUFS JONN 8FJHIU MCLH .BUFSJBM 1PMZQSPQZMFOF Operating Environment 5FNQFSBUVSF 0VUEPPS4QFBLFST ¡'¡'¡$¡$ 3FMBUJWF)VNJEJUZ OPODPOEFOTJOH Audio Performance 'SFRVFODZ3FTQPOTF )[UPL)[ /PNJOBM1PXFS3BUJOH 83.4 *NQFEBODF 0IN 4FOTJUJWJUZ E# *Polypropylene drivers have a second order 12/12 dB crossover for both tweeter and woofer *For Diagram see technical section page 116 Catalog Number Description 4-$*81 *O8BMM1PMZQSPQZMFOFTQFBLFST 4-$*8, *O8BMM,FWMBSTQFBLFST 4-$*$1 *O$FJMJOH1PMZQSPQZMFOFTQFBLFST 4-$*$, *O$FJMJOH,FWMBSTQFBLFST 4-$0%1#, 0VUEPPS#MBDL1PMZQSPQZMFOFTQFBLFST 4-$0%18& 0VUEPPS8IJUF1PMZQSPQZMFOFTQFBLFST t'MVTINPVOUTIFMGNPVOUBOETVSGBDF mount models t*OEPPSBOEPVUEPPSNPEFMT t)JHIJNQBDUQMBTUJDDPNQPOFOUTBOE powder coated metal grills produce a longlasting unit suitable for indoor and outdoor use t"WBJMBCMFXJUI,FWMBS® (indoor units only) or polypropylene drivers (indoor and outdoor units) for high-quality sound in all applications t"MMNPEFMTBSFPGGUIFþPPSTBWJOHþPPS space t$POWFOJFOUBOESFMJBCMFTPVOEDPWFSBHF almost completely independent of furniture or entertainment equipment layout t*OEPPS0VUEPPS4QFBLFSTIBWFBQSF JOTUBMMFESFNPWBCMFNPVOUJOHCSBDLFU t*OEPPS0VUEPPS4QFBLFSTDBOCFQMBDFE on a shelf or hung from a surface by their CSBDLFUJODMVEFE t5SBDJOHQBJOUJOHUFNQMBUFJODMVEFE 94 C-BUSTM AUDIO + REMOTE CONTROLS C-BusTM Universal Remote 5IF$#VT5. Universal Remote is a digital universal remote control that is easy to use, allowing control of electronic devices that are equipped with an infrared remote. 5IF4DIOFJEFS&MFDUSJD$#VT6OJWFSTBM3FNPUFDBODPOUSPMVQUPEFWJDFTJODMVEJOH $#VTEFWJDFT%7%T57T7$3TBOETBUFMMJUFSFDFJWFST 5IFSFNPUFJTFBTJMZDPOýHVSFECZVTJOHFJUIFSBVUPNBUJDDPEFEFUFDUJPOPSUIFMFBSO option. *OBEEJUJPOUIFBEWBODFENBDSPGVODUJPOBMMPXTUIFSFDPSEJOHPGBDIBJOPGVQUP commands with the single touch of a button. 6OJWFSTBM3FNPUF$POUSPM Technical Information Product Features -$%4DSFFO JO8 YJO) #BDLMJHIUJOH #SJMMJBOUCMVF-&% -FBSOJOH'SFRVFODZ L)[UPL)[QVMTF .FNPSZ L#þBTINFNPSZ #BUUFSJFT 6TFT""" BMLBMJOFCBUUFSJFTOPUJODMVEFE 5PVDI4DSFFO4PGU,FZT LFZT 3VCCFS)BSE#VUUPOT CVUUPOT 1PXFS -$%0GG" $POTVNQUJPO -$%0O" 0QFSBUJPON".BY 0QFSBUJOH%JTUBODF %JNFOTJPOT "QQSPYGFFU JO8 YJO) YJO% <NN8 YNN) YNN% > 8FJHIUXPCBUUFSJFT P[H *For Diagram see technical section page 122 95 Catalog Number Description 4-$63$ 6OJWFSTBM3FNPUF$POUSPM t-BSHFUPVDITDSFFOEJTQMBZXJUI-&%CBDLMJHIU t.BDSPGVODUJPOVQUPDPNNBOETQFSNBDSP t-FBSOTJOGSBSFEDPEFTGSPNPSJHJOBMFRVJQNFOU remote controls t6TFSQSPHSBNNBCMFCVUUPOTGPSFBDIEFWJDF t1SFQSPHSBNNFENBOVGBDUVSFSTDPEFT t.VMUJQMFUJNFSTEBZPGXFFLEBUFBOEiBMBSNw to automate functions (i.e., record movies, turn on music) t2VJDLDIBOOFMCVUUPOT t'BWPSJUFDIBOOFMTHSPVQJOH t#VJMUJONPUJPOEFUFDUPS t4ZTUFNTFUVQUSBOTNJTTJPO t4MFFQNPEF Distributed Intelligence t$PNQBUJCMFXJUI$Bus%evices C-BUSTM AUDIO + REMOTE CONTROLS C-BusTM Four & Eight Button Remote Controllers 5IF$#VT5.'PVSBOE&JHIU#VUUPO*OGSBSFE*3 3FNPUF$POUSPMMFSTQSPWJEFIBOEIFME SFNPUFDPOUSPMPQFSBUJPOPGMJHIUJOHBOEPUIFSMPBET%FTJHOFEUPXPSLJODPOKVODUJPOXJUI $#VTEFWJDFTDPOUBJOJOH*3SFDFJWFSTUIFTFDPOWFOJFOUSFNPUFDPOUSPMTDBOTXJUDIEJN and control lighting scenes. $#VT'PVSBOE&JHIU#VUUPO3FNPUF$POUSPMMFSTDPOUSPMNVMUJQMFJOQVUVOJUTBTXFMMBT separately configured units. 5IFTFWFSTBUJMFSFNPUFDPOUSPMTIBWFBSBOHFPGVQUPGFFUNFUFST BOEBSFFBTJMZ DPOýHVSFECZQSPHSBNNJOHUIF*3SFDFJWJOHEFWJDFJOUIF$#VT5PPMLJUTPGUXBSF BOE#VUUPO3FNPUF$POUSPMT Product Features Technical Information 4VQQMZ7PMUBHF #BUUFSZ5ZQF 7%$SFRVJSFEGPSOPSNBMPQFSBUJPO Y"""BMLBMJOF4QFBLFS%JBNFUFS *35SBOTNJTTJPO3BOHF 6QUPGUN %JNFOTJPOT JO- YJO8 YJO% <NN- YNN8 YNN% > 8FJHIUXPCBUUFSJFT P[H t'PVSBOE&JHIUCVUUPOPQUJPOT t8BMMNPVOUTUPSBHFIPMEFSJODMVEFEXJUI each remote control t3FNPWFBCMFGSPOUDPWFSGPSMBCFMJOTFSUJPO (labels included) t """CBUUFSJFTJODMVEFE Distributed Intelligence t$PNQBUJCMFXJUI$#VT*3*OQVUEFWJDFT Remote Control Holder %JNFOTJPOT JO- YJO8 YJO% <NN- YNN8 YNN% .PVOUJOH$FOUFST JONN .PVOUJOH4DSFX4J[F JO þBUIFBEXPPETDSFXNNYNN 8BMM"ODIPS4J[F JONNYNN 8FJHIU P[H *For Diagram see technical section page 122 Catalog Number Description 4-$59 'PVS#VUUPO*33FNPUF$POUSPMMFS 4-$59 &JHIU#VUUPO*33FNPUF$POUSPMMFS 96 C-BUSTM AUDIO + MULTI-ROOM AUDIO IR Accessories IR TUBE TARGET Infra-red IR target designed to receive IR commands from Infra-red remote controls. 4JNQMFJODFJMJOHNPVOUJOH*ODMVEFTQIPFOJYDPOOFDUPSBOENFUFSTPGXJSF$PNFT with optional clear lens. IR Shelf Mount Target Infra-red IR target designed to receive IR commands from Infra-red remote controls. Simply set unit on shelf for easy IR command access. Includes phoenix connector and 2 meters of wire. IR Flat Target Infra-red IR target designed to receive IR commands from Infra-red remote controls. %FTJHOFEUPNPVOUJOEJGGVTFSTBOETNBMMBSFBTUPNBTLBQQFBSBODF*ODMVEFTQIPFOJY connector and 2 meters of wire. IR Emitter Leads *3-FBETQMVHJOUPUIF$#VT.VMUJSPPNBVEJPNBUSJYTXJUDIFSPS$#VT/JSUTBOEFNJU IR codes to the third party devices. Single and dual emitter leads available. Includes USBOTQBSFOUBEIFTJWFTUJDLFSGPSBQQMJDBUJPO NIRT 5IF$#VT/*35JTBXBMMNPVOUFE*3USBOTNJUUFSUIBUJTEFTJHOFEUPXPSLXJUIUIF $#VTDPOUSPMTZTUFN5IF/*35USBOTNJUTVQUPDIBOOFMTPG*3DPNNBOETUPDPOUSPM UIJSEQBSUZDPNQPOFOUTJF%7%QMBZFST57TFUD IR Reader 5IF$#VT*33FBEFSJTBQSPHSBNNJOHUPPMUIBUJTVTFEUPMFBSOSEQBSUZSFNPUFDPOUSPM *3DPNNBOET6TJOH$JSDBTPGUXBSFGSFFEPXOMPBE QMVH*33FBEFSJOUPB1$WJB64# QPSUBOETFOESFNPUFDPOUSPMTJHOBMDBQUVSF*3$PEF 97 Catalog Number Description 4-$55 *35VCF5BSHFU 4-$45 *34IFMG.PVOU5BSHFU 4-$'5 *3'MBU5BSHFU 4-$-% *3&NJUUFS-FBET4JOHMF 4-$-% *3&NJUUFS-FBET%VBM 4-$/*35 *35SBOTNJUUFS 4-$31 *33FBEFS C-BUS® ADUIO + TECHNICAL SECTION Matrix Switcher 10.875 in. in. 10.875 27.6 cm 27.6 cm 14.125 in. 17.125 43.5 mmin. 43.5 cm 3.125 3.125in. in. cm 7.97.9mm 5PQ7JFX Multi-Room Amplifiers 11 in. 280 mm %FTLUPQ.PEFM "VEJP "NQMJýFS 2.6 in. 66 mm 7.6 in. 194 mm 4.1 in. 105 mm .31 in. 8 mm 7.09 in. 180 mm 5PQ7JFX 'SPOU7JFX 1.1 in. 28 mm 3FNPUF.PEFM "VEJP "NQMJýFS 2.44 in. 62 mm 1.1 in. 28 mm 4.13 in. 105 mm 6.89 in. 175 mm 5PQ7JFX 0.31 in. 8 mm .11 in. 2.9 mm 'SPOU7JFX 98 C-BUS® AUDIO + TECHNICAL SECTION Audio Distribution Unit LQ 5.61 in. PP 142.5 mm LQ 6.52 in. PP 165.5 mm 1.20 in. LQ 30.5 mm PP 1.97 in. LQ 50 mm PP 5PQ7JFX Bottom Audio Speakers 3.125 in. 79.38 mm 9.45 in. 240 mm 8.7 in. 221 mm 8.7 in. 221 mm $FJMJOH.PVOU4QFBLFS%JNFOTJPOT 12.125 in. 308 mm 12.125 in. 308 mm 3.125 in. 79 mm 6.75 in. 171 mm 6.0 in. 152 mm 8BMM.PVOU4QFBLFS%JNFOTJPOT 9.8 in. 248 mm 0VUEPPS4QFBLFS%JNFOTJPOT 99 C-BUS® ADUIO + TECHNICAL SECTION C-BusTM Universal Remote 2.4 in. 61 mm 8.3 in. 210 mm C-BusTM Four & Eight Button Remote Controllers 2.2 in. 2.2 in 55 mm 1.3 in. 1.3 in 32 mm 32 mm 55 mm 2.1 in. 2.1 in 52 mm 52 mm 2.1 in. 2.1 in 52 mm mm 52 4.3 in. 4.3 in 108 mm 108 mm 5.9 in. 5.9 in 149 mm 149 mm 5.9 in. 5.9 in 149 mm 149 mm $-BusBOE#VUUPO3FNPUF$POUSPM)PMEFS $-Bus#VUUPO3FNPUF$POUSPM 11 in. in 25 mm mm 25 $-Bus#VUUPO3FNPUF$POUSPM 100 TM C-Bus HVAC Controls 101 Introduction to C-BusTM HVAC Controls $#VT5. thermostats are used to regulate the air temperature of zones by controlling heatingWFOUJMBUJPOBJSDPOEJUJPOJOH)7"$ FRVJQNFOU 8JUI$#VTUIFSNPTUBUTZPVIBWFUIF þFYJCJMJUZPGBOZLFZQBECFDPNJOHBDPNGPSU DPOUSPMQPJOU$#VTUIFSNPTUBUTNBZPQFSBUF as stand alone devices, or be controlled via PUIFS$#VTEFWJDFTTVDIBTXBMMTXJUDIFTPS touch screens. 1SPHSBNNBCMFGPVS[POF5IFSNPTUBUTDBO schedule up to four set points during a day, and unique schedules can be programmed GPSFBDIEBZPGUIFXFFL#PUINPEFMTJODMVEF TFUCBDLNPEFTBWFTQPXFSCZVTJOHB wider acceptable temperature range within which heating or cooling is not performed) and temperature guard (ensures the temperature is maintained within a specified temperature range). 102 C-BUSTM CONTROL + HVAC C-BusTM Basic Single Zone Thermostats 5IF$#VTXBMMNPVOUFE4JOHMF;POF5IFSNPTUBUTJODMVEFTVQQPSUGPSDPOUSPMPG )7"$VOJUTWJB$#VTPSUIFJOUFSOBM)7"$SFMBZT5IFZBMTPBMMPXUIFVTFSUPNBOVBMMZ TFUUIFUFNQFSBUVSFBOENPEFPGPQFSBUJPOIFBUJOHDPPMJOHPSWFOUJMBUJPO 5IFFBTZUP VTFPQFSBUPSJOUFSGBDFJODMVEFTGBOTQFFEDPOUSPMTFUCBDLPSFDPOPNZNPEFBOEBO JOUFHSBM-$%UPEJTQMBZUIFDVSSFOUUFNQFSBUVSFBOENPEFPGPQFSBUJPO t5FNQFSBUVSFBEKVTUNFOUGSPNUIFVOJU t"EFEJDBUFE)7"$DPOUSPMMFSWJBUIFPOCPBSESFMBZT t"$#VT3FMBZVOJU t.PEFCVUUPOJFIFBUJOHDPPMJOHWFOUJMBUJPO t.BOVBMGBOTQFFEDPOUSPM t*ODPSQPSBUFTATFUCBDLNPEF t1SPHSBNNBCMFWJB$#VT5PPMLJUTPGUXBSF t#SPBEDBTUTUIFEJTQMBZFEUFNQFSBUVSFPO$#VT t$BOGVMMZJOUFHSBUFXJUIUIF$#VT/FUXPSL t6-D6-MJTUFE #BTJD5IFSNPTUBU C-BusTM Programmable 4 Zone Thermostats 5IF$#VT5.1SPHSBNNBCMF;POF5IFSNPTUBUTJODMVEFPOCPBSEEBZ)7"$UJNF TDIFEVMJOHVTFSQSPHSBNNBCMF NBOVBMGBOTQFFEDPOUSPMTFUCBDLNPEFBOEBOFBTZ UPVTFJOUFSGBDFDPNQSJTJOHPGBO-$%NBOVBMDPOUSPMCVUUPOTBOEBSPUBUJOHEJBMXJUI an integral press switch. From the unit, the user can manually adjust the temperature set point, the mode of operation (heating, cooling, ventilation) and time schedules. t'VMMEBZQSPHSBNNBCMFTDIFEVMFFWFOUTQFSEBZ t"DDFQUTVQUPGPVSSFNPUFUFNQFSBUVSFTFOTPSJOQVUTWJB$#VT t'PVS[POFTQMVTDPNNPOVOTXJUDIFE [POF t4FUBOEDPOUSPMWJBPUIFS$#VTEFWJDFT t4VQQPSUTTFUCBDLUFNQFSBUVSFT t1PXFSFEGSPN$#VT t#BDLMJU-$%BOECVUUPOT t*OUFHSBMUFNQFSBUVSFTFOTPS t.BOVBMGBOTQFFEDPOUSPM t;POFCVUUPOTFUTUIFBDUJWF[POFTJOUIFTZTUFN t$BOGVMMZJOUFHSBUFXJUIUIF$#VT/FUXPSL t6-D6-MJTUFE 103 1SPHSBNNBCMF5IFSNPTUBU[POF Catalog Number Description Catalog Number Description 4-$5)#8& 4JOHMF;POF5IFSNPTUBU8IJUFOPPOCPBSESFMBZT 4-$5)18&;POF5IFSNPTUBU8IJUFOPPOCPBSESFMBZT 4-$5)##, 4JOHMF;POF5IFSNPTUBU#MBDLOPPOCPBSESFMBZT 4-$5)1#,;POF5IFSNPTUBU#MBDLOPPOCPBSESFMBZT 4-$5)#44 4JOHMF;POF5IFSNPTUBU4UBJOMFTTOPPOCPBSESFMBZT 4-$5)144;POF5IFSNPTUBU4UBJOMFTTOPPOCPBSESFMBZT 4-$5)#38& 4JOHMF;POF5IFSNPTUBU8IJUFXSFMBZ 4-$138&;POF5IFSNPTUBU8IJUFXSFMBZ 4-$5)#3#, 4JOHMF;POF5IFSNPTUBU#MBDLXSFMBZ 4-$13#,;POF5IFSNPTUBU#MBDLXSFMBZ 4-$5)#344 4JOHMF;POF5IFSNPTUBU4UBJOMFTTXSFMBZ 4-$1344;POF5IFSNPTUBU4UBJOMFTTXSFMBZ C-BUSTM CONTROL + TECHNICAL SECTION C-BusTM Basic Single Zone Thermostats 3.62 in. 92 mm 5.0 in. 127 mm 1.06 in. 27 mm C-BusTM Programmable 4 Zone Thermostats 4.13 in. 105 mm 5.9 in. 150 mm 1.26 in. 32 mm 104 TM C-Bus RF Wireless Controls 105 Introduction to C-BusTM RF Wireless Controls #SFBLMPPTFGSPNUIFDVNCFSTPNFXJSJOH and associated cost of home control systems XJUI$#VT3'XJSFMFTTDPNNVOJDBUJPO %FTJHOFEUPFBTJMZSFQMBDFTUBOEBSEXBMM TXJUDIFT$#VT3'PGGFSTTFBNMFTTEJNNJOH and scene control technology with the elegant aesthetic of Neo™ and Saturn™ decoratorTUZMFLFZQBET $#VT3'8JSFMFTT8BMM6OJUTJODMVEF 4XJUDIFTMFBEJOHoFEHF%JNNFSTBOE4DFOF $POUSPMMFST5IFVOJUTBSFEFTJHOFEUPSFQMBDF standard wall switches and dimmers. By eliminating the need for additional wiring runs, $#VT3'PGGFSTUIFQFSGFDUTPMVUJPOGPSSFUSPýU applications. *OUFMMJHFOU*OOPWBUJWF$#VT3'GFBUVSFTBO all-in-one solution that other wireless control TZTUFNTTJNQMZEPOUIBWFyDPNQMFUF functionality in every device, eliminating the need for stand-alone repeaters and central controllers. 106 C-BUSTM WIRELESS CONTROLS + WIRELESS CONTROLS C-BusTM RF Wireless Controls 600W RF Dimmers $#VT5.3'8JSFMFTTEJNNFSTPQFSBUFBMMDPNNPOMJHIUJOHMPBETBOEXPSLJO DPOKVODUJPOXJUIPUIFS$#VTXJSFEBOEXJSFMFTTDPOUSPMTUPQSPWJEFGVMMEJNNJOHDPOUSPM 5IFTFEFDPSBUPSTUZMFMFBEJOHFEHFEJNNFSTBSFBWBJMBCMFJOCPUIUIF/FP5. and Saturn5.TUZMFTXJUIFJUIFSPSCVUUPODPOýHVSBUJPO /FPBOE4BUVSO%FDPSBUPS4UZMF,FZQBET Technical Information Product Features 4VQQMZ7PMUBHF 7"$!)[ 3''SFRVFODZ .I[ 5SBOTNJUUJOH1PXFS N8 5ZQJDBM3BOHF (range depends on building DPOTUSVDUJPOBOEQSPYJNJUZUP EFOTFPSNFUBMMJDPCKFDUT UPGUUPN JOCVJMEJOHTXJUI UJNCFSGSBNFCSJDLWFOFFSDPOTUSVDUJPO UPGUUPN JOCVJMEJOHTXJUI CSJDLTUPOFPSTUFFMGSBNFDPOTUSVDUJPO UPGUUPN JOCVJMEJOHTXJUITUFFM reinforced concrete construction .BYJNVN3BOHF GUN JOPQFOBJS 4UBUVT*OEJDBUPS $PMPS#VUUPOTBOESFTFUCMVF -FBSOoSFEVOJUOPUTFUVQBTBSFQFBUFS blue (unit set up as a repeater) 8BSN6Q5JNF 4FDPOET 0QFSBUJOH5FNQFSBUVSF3BOHF UP0'UP0$ 0QFSBUJOH)VNJEJUZ3BOHF UP3) 0GG4UBUF1PXFS$POTVNQUJPO 8 0GG4UBUF-FBLBHF$VSSFOU N" $POUSPM'VODUJPOT -PBETXJUDIJOHEJNNJOHUJNFSTDFOFT .JO-PBE1FS$IBOOFM 8 .BY-PBE1FS$IBOOFM 8 $PNQBUJCMF-PBET3BUJOH *ODBOEFTDFOU5VOHTUFO*SPO$PSF5SBOT-PX 7PMUBHF-JHIUJOH" %JNFOTJPOT)Y8Y% JOYJOYJONNYNNYNN %JNFOTJPOTX)FBUTJOL JOYJONNYNN 8FJHIU P[H 'JYJOH$FOUFST JONN 4UBOEBSET 6--JTUFE"4PMJE4UBUF$POUSPMT'PS"QQMJBODFT "QQMJBODFT '$$1BSU$MBTT#%JHJUBM%FWJDFGPS)PNFPS0GýDF6TF ** For additional ordering information see technical section page 135 Catalog Number Description 4-$Y %-6.YY /FP%FDPSBUPS4UZMF3'8%JNNFS 4-$Y %-6.YY 4BUVSO%FDPSBUPS4UZMF3'8%JNNFS /PUF8BMMQMBUF4PME4FQBSBUFMZ3FGFSUPJOEJWJEVBMQSPEVDUNBOVBMGPSPSEFSJOGPSNBUJPO 107 BOECVUUPOPQUJPOT t.PVOUTJOTUBOEBSEXBMMCPY t/FPPS4BUVSO%FDPSBUPS4UZMJOH t.VMUJGVODUJPOCVUUPOTDPOýHVSBCMFUP DPOUSPMBOZMPBEPOUIF$#VTOFUXPSL t-BTUMFWFMCVUUPOSFDBMMQSFTFU t$PNQBUJCMFXJUIBXJSFE$#VTTZTUFN using wireless gateway (not included) t$PNQBUJCMFXJUI$#VTXJSFMFTTSFNPUFOPU included) t/POFVUSBMSFRVJSFE Keypad ordering: Neo Style t0SEFSOVNCFSTGPSUIF/FP3'EFDPSBUPS TUZMFLFZQBETJOEJDBUFUIFOVNCFSPG CVUUPOTEFTJSFEPOUIFLFZQBEBOEUIF DPMPSPGUIFLFZQBEJUTFMG tBOECVUUPOTBWBJMBCMFDPMPSDPEFTBSF 4MBUF(# 8IJUF8& $SFBN$. 4PGU HSBZ4( %FTFSUTBOE%4 #MBDL#, BOE#SPXO#3 'PSFYBNQMF4-$ %-6.%4 SFQSFTFOUTBOPSEFSGPSB/FP 3'LFZQBEXJUIGPVSCVUUPOTJO%FTFSU Sand. Keypad ordering: Saturn Style t0SEFSOVNCFSTGPSUIF4BUVSO3'EFDPSBUPS TUZMFLFZQBEJOEJDBUFUIFOVNCFSPGCVUUPOT EFTJSFEPOUIFLFZQBEBOEUIFDPMPSPGUIF LFZQBEJUTFMG tBOECVUUPOTBWBJMBCMFDPMPSDPEFTBSF 8IJUF8& $SFBN$. #MBDL#, BOE.PDIB#3 t'PSFYBNQMF4-$ %-6.#, represents an order for a Saturn RF EFDPSBUPSLFZQBEXJUIGPVSCVUUPOTJOCMBDL C-BUSTM WIRELESS CONTROLS + WIRELESS CONTROLS C-BusTM RF Wireless Controls 1000W RF Dimmers $#VT5.3'8JSFMFTTEJNNFSTPQFSBUFBMMDPNNPOMJHIUJOHMPBETBOEXPSLJO DPOKVODUJPOXJUIPUIFS$#VTXJSFEBOEXJSFMFTTDPOUSPMTUPQSPWJEFGVMMEJNNJOHDPOUSPM 5IFTFEFDPSBUPSTUZMFMFBEJOHFEHFEJNNFSTBSFBWBJMBCMFJOCPUIUIF/FP5. and Saturn5.TUZMFTXJUIFJUIFSPSCVUUPODPOýHVSBUJPO /FPBOE4BUVSO%FDPSBUPS4UZMF,FZQBET Technical Information Product Features 4VQQMZ7PMUBHF 7"$!)[ 3''SFRVFODZ .I[ 5SBOTNJUUJOH1PXFS N8 5ZQJDBM3BOHF SBOHFEFQFOETPOCVJMEJOH DPOTUSVDUJPOBOEQSPYJNJUZUP EFOTFPSNFUBMMJDPCKFDUT UPGUUPN JOCVJMEJOHTXJUI UJNCFSGSBNFCSJDLWFOFFSDPOTUSVDUJPO UPGUUPN JOCVJMEJOHTXJUI CSJDLTUPOFPSTUFFMGSBNFDPOTUSVDUJPO UPGUUPN JOCVJMEJOHTXJUITUFFM reinforced concrete construction .BYJNVN3BOHF GUN JOPQFOBJS .BYJNVN6OJUTPOB/FUXPSL 6OJUT 4UBUVT*OEJDBUPS $PMPS#VUUPOTBOESFTFUCMVF -FBSOoSFEVOJUOPUTFUVQBTBSFQFBUFS blue (unit set up as a repeater) 8BSN6Q5JNF 4FDPOET 0QFSBUJOH5FNQFSBUVSF3BOHF UP0'UP0$ 0QFSBUJOH)VNJEJUZ3BOHF UP3) 0GG4UBUF1PXFS$POTVNQUJPO 8 0GG4UBUF-FBLBHF$VSSFOU N" $POUSPM'VODUJPOT -PBETXJUDIJOHEJNNJOHUJNFSTDFOFT .JO-PBE1FS$IBOOFM 8 .BY-PBE1FS$IBOOFM 8 $PNQBUJCMF-PBET3BUJOH *ODBOEFTDFOU5VOHTUFO*SPO$PSF5SBOT-PX 7PMUBHF-JHIUJOH" %JNFOTJPOT)Y8Y% JOYJOYJONNYNNYNN %JNFOTJPOTX)FBUTJOL JOYJONNYNN 8FJHIU P[H 'JYJOH$FOUFST JONN 4UBOEBSET 6--JTUFE"4PMJE4UBUF$POUSPMT'PS"QQMJBODFT "QQMJBODFT '$$1BSU$MBTT#%JHJUBM%FWJDFGPS)PNFPS0GýDF6TF BOECVUUPOPQUJPOT t.PVOUTJOTUBOEBSEXBMMCPY t/FPPS4BUVSO%FDPSBUPS4UZMJOH t.VMUJGVODUJPOCVUUPOTDPOýHVSBCMFUP DPOUSPMBOZMPBEPOUIF$#VTOFUXPSL t-BTUMFWFMCVUUPOSFDBMMQSFTFU t$PNQBUJCMFXJUIBXJSFE$#VTTZTUFN using wireless gateway (not included) t$PNQBUJCMFXJUI$#VTXJSFMFTTSFNPUFOPU included) t/POFVUSBMSFRVJSFE Keypad ordering: Neo Style t0SEFSOVNCFSTGPSUIF/FP3'EFDPSBUPS TUZMFLFZQBETJOEJDBUFUIFOVNCFSPG CVUUPOTEFTJSFEPOUIFLFZQBEBOEUIFDPMPS PGUIFLFZQBEJUTFMG tBOECVUUPOTBWBJMBCMFDPMPSDPEFTBSF 4MBUF(# 8IJUF8& $SFBN$. 4PGU HSBZ4( %FTFSUTBOE%4 #MBDL#, BOE #SPXO#3 'PSFYBNQMF4-$ %-6.%4 SFQSFTFOUTBOPSEFSGPSB/FP 3'LFZQBEXJUIGPVSCVUUPOTJO%FTFSU4BOE Keypad ordering: Saturn Style t0SEFSOVNCFSTGPSUIF4BUVSO3'EFDPSBUPS TUZMFLFZQBEJOEJDBUFUIFOVNCFSPGCVUUPOT EFTJSFEPOUIFLFZQBEBOEUIFDPMPSPGUIF LFZQBEJUTFMG tBOECVUUPOTBWBJMBCMFDPMPSDPEFTBSF 8IJUF8& $SFBN$. #MBDL#, BOE .PDIB#3 t'PSFYBNQMF4-$ %-6.#, represents an order for a Saturn RF EFDPSBUPSLFZQBEXJUIGPVSCVUUPOTJOCMBDL ** For additional ordering information see technical section page 135 Catalog Number Description 4-$Y %-6.YY /FP%FDPSBUPS4UZMF3'8%JNNFS 4-$Y %-6.YY 4BUVSO%FDPSBUPS4UZMF3'8%JNNFS /PUF8BMMQMBUF4PME4FQBSBUFMZ3FGFSUPJOEJWJEVBMQSPEVDUNBOVBMGPSPSEFSJOGPSNBUJPO 108 C-BUSTM WIRELESS CONTROLS + WIRELESS CONTROLS C-BusTM RF Wireless Controls RF Switch and Scene Controllers 5IF$#VT/FP5. and Saturn5.3'4XJUDIFTBOE4DFOF$POUSPMMFSTBSFQBSUPGUIF $#VTXJSFMFTTXBMMVOJUGBNJMZ5IFTXJUDIFTBSFBUXPXJSFSFUSPýUSBOHFVTJOHUIF TXJUDIJOHMFHMJOFBOEMPBE 4XJUDIFTBSFBWBJMBCMFJOBOECVUUPONPEFMTBOE DPNFJOBEFDPSBUPSTUZMF4DFOF$POUSPMMFSTDBOCFVTFEGPSXBZTXJUDIJOHXBZ TXJUDIJOHPSTDFOFDPOUSPM5IFZVTFBMJOFBOEOFVUSBMDPOOFDUJPO4DFOF$POUSPMMFST BSFBWBJMBCMFJOCVUUPONPEFMT /FPBOE4BUVSO%FDPSBUPS4UZMF,FZQBET Technical Information Product Features 4VQQMZ7PMUBHF 7"$!)[ 3''SFRVFODZ .I[ 5SBOTNJUUJOH1PXFS N8 5ZQJDBM3BOHF SBOHFEFQFOETPOCVJMEJOH DPOTUSVDUJPOBOEQSPYJNJUZUP EFOTFPSNFUBMMJDPCKFDUT UPGUUPN JOCVJMEJOHTXJUI UJNCFSGSBNFCSJDLWFOFFSDPOTUSVDUJPO UPGUUPN JOCVJMEJOHTXJUI CSJDLTUPOFPSTUFFMGSBNFDPOTUSVDUJPO UPGUUPN JOCVJMEJOHTXJUITUFFM reinforced concrete construction .BYJNVN3BOHF GUN JOPQFOBJS 4UBUVT*OEJDBUPS$PMPS #VUUPOTBOESFTFUCMVF -FBSOoSFEVOJUOPUTFUVQBTBSFQFBUFS blue (unit set up as a repeater) 8BSN6Q5JNF 4FDPOET 0QFSBUJOH5FNQFSBUVSF3BOHF UP0'UP0$ 0QFSBUJOH)VNJEJUZ3BOHF UP3) 0GG4UBUF1PXFS$POTVNQUJPO 8 0GG4UBUF-FBLBHF$VSSFOU N" $POUSPM'VODUJPOT -PBETXJUDIJOHUJNFSTDFOFT .JO-PBE1FS$IBOOFM 8 .BY-PBE1FS$IBOOFM " $PNQBUJCMF-PBET3BUJOHTXJUDI '-".PUPS *ODBOEFTDFOU5VOHTUFO'MVPSFTDFOU#BMMBTU .BHOFUJD&MFDUSPOJD-PX7PMUBHF-JHIUJOH)*% )JHIJOUFOTJUZEJTDIBSHF " -3"" %JNFOTJPOT)Y8Y% JOYJOYJONNYNNYNN %JNFOTJPOTX)FBUTJOL JOYJONNYNN 8FJHIU P[H 'JYJOH$FOUFST JONN 4UBOEBSET 6--JTUFE"4PMJE4UBUF$POUSPMT'PS"QQMJBODFT "QQMJBODFT '$$1BSU$MBTT#%JHJUBM%FWJDFGPS)PNFPS0GýDF6TF ** For additional ordering information see technical section page 135 Catalog Number Description 4-$/-.YY /FP%FDPSBUPS4UZMF3'4DFOF$POUSPMMFSCVUUPOPOMZ 4-$/-.YY 4BUVSO%FDPSBUPS4UZMF3'4DFOF$POUSPMMFSCVUUPOPOMZ /PUF8BMMQMBUF4PME4FQBSBUFMZ3FGFSUPJOEJWJEVBMQSPEVDUNBOVBMGPSPSEFSJOGPSNBUJPO 109 t/FPBOE4BUVSO%FDPSBUPS4UZMF,FZQBET t6TFJOBOEXBZBQQMJDBUJPOT4DFOF $POUSPMMFS t$POUSPM4DFOFTBOE-PBET 4XJUDIDPOUSPMTTDFOFTMPBET 4DFOFDPOUSPMMFSNVMUJMPDBUJPOTXJUDIJOH scene control t$PMPSPQUJPOT /FP4MBUF8IJUF$SFBN#SPXO4PGU(SFZ #MBDLBOE%FTFSU4BOE 4BUVSO8IJUF$SFBN.PDIBBOE#MBDL t$PNQBUJCMFXJUIBXJSFE$#VTTZTUFN using wireless gateway (not included) t&BTZSFUSPýUPQUJPO t/POFVUSBMSFRVJSFE Keypad ordering: Neo Style t0SEFSOVNCFSTGPSUIF/FP3'EFDPSBUPS TUZMFLFZQBETJOEJDBUFUIFOVNCFSPG CVUUPOTEFTJSFEPOUIFLFZQBEBOEUIF DPMPSPGUIFLFZQBEJUTFMG tPSCVUUPOTBWBJMBCMFDPMPSDPEFTBSF 4MBUF(# 8IJUF8& $SFBN$. 4PGU HSBZ4( %FTFSUTBOE%4 #MBDL#, BOE Brown (BR). t'PSFYBNQMFSFQSFTFOUTBOPSEFSGPSB/FP 3'LFZQBEXJUIGPVSCVUUPOTJO%FTFSU Keypad ordering: Saturn Style t0SEFSOVNCFSTGPSUIF4BUVSO3'EFDPSBUPS TUZMFLFZQBEJOEJDBUFUIFOVNCFSPGCVUUPOT EFTJSFEPOUIFLFZQBEBOEUIFDPMPSPGUIF LFZQBEJUTFMG tBOECVUUPOTBWBJMBCMFDPMPSDPEFTBSF 8IJUF8& $SFBN$. #MBDL#, BOE .PDIB#3 t'PSFYBNQMF4-$ 3'6.%4 represents an order for a Saturn RF EFDPSBUPSLFZQBEXJUIGPVSCVUUPOTJOCMBDL C-BUSTM WIRELESS CONTROLS + WIRELESS CONTROLS C-BusTM RF Wireless Controls Plug Adaptors $#VT5.3'1MVH"EBQUPSTBMMPXUIFDPOUSPMPGBQQMJBODFTBOEPSMBNQTVTJOH$#VT3' 8JSFMFTT,FZQBET1MVHBEBQUPSTDPNFJOUXPEJGGFSFOUNPEFMTBTUBOEBSETXJUDIVOJU " PS8EJNNFSVOJU#PUINPEFMTBSFQSPHSBNFEFBTJMZVTJOH-FBSO.PEFPSCZ VTJOHUIF$#VT5PPMLJU4PGUXBSF 1MVH"EBQUPS Technical Information Product Features 4VQQMZ7PMUBHF 7"$!)[ 4VQQMZWPMUBHF 7"$!)[ 3'GSFRVFODZ .I[ 5SBOTNJUUJOHQPXFS N8 5ZQJDBMSBOHF 3BOHFEFQFOETPOCVJMEJOH DPOTUSVDUJPOBOEUIFQSPYJNJUZUP EFOTFPSNFUBMMJDPCKFDUT øUPGUUPN JOCVJMEJOHTXJUI UJNCFSGSBNFCSJDLWFOFFSDPOTUSVDUJPO UPGUUPN JOCVJMEJOHTXJUI CSJDLTUPOFPSTUFFMGSBNFDPOTUSVDUJPO UPGUUPN JOCVJMEJOHTXJUITUFFMSFJOGPSDFE concrete construction .BYJNVNSBOHFø GUN JOPQFOBJS $POUSPMGVODUJPOT -PBETXJUDIJOHUJNFS-&EJNNJOHEJNNFS Status Indicator color t1MVHTJOUPBTUBOEBSEHFOFSBMQVSQPTF electrical outlet t$PNNVOJDBUFTEJSFDUMZXJUIPUIFS$#VT wireless devices t#PUIEJNNJOHBOESFMBZPVUQVUNPEFMT available t3FMBZPVUQVUWFSTJPOBWBJMBCMF" t*OUFHSBMFBTJMZBDDFTTJCMFDPOUSPMPWFSSJEF programming buttons t$BOCFDPOUSPMMFEWJB$#VTXJSFEJOQVU VOJUTWJBB8JSFMFTT3'(BUFXBZ6OJU t6OJRVF$#VTXJSFMFTTIPVTFDPEF t&ODSZQUFEDPNNVOJDBUJPOT t1SPHSBNNBCMFWJB$#VTMFBSONPEFPSWJB $#VT5PPMLJU4PGUXBSF Blue 8BSNVQUJNFø TFDPOET 0QFSBUJOHUFNQFSBUVSFSBOHF UP¡$ 0QFSBUJOHIVNJEJUZSBOHF UP3) .JOMPBEQFSDIBOOFM 8 .BYMPBEQFSDIBOOFM 8EJNNFS "4XJUDI $PNQBUJCMFMPBETSBUJOH%JNNFS $PNQBUJCMFMPBETSBUJOH4XJUDI *ODBOEFTDFOU5VOHTUFO*SPODPSFUSBOT -7MJHIUJOH" *ODBOEFTDFOU5VOHTUFO'MVPSFTDFOU#BMMBTU.BHOFUJD &MFDUSPOJD-7MJHIUJOH)*%" )JHI*OUFOTJUZ%JTDIBSHF " '-".PUPS -3"" 0GGTUBUFQPXFSDPOTVNQUJPO 8 0GGTUBUFMFBLBHFDVSSFOU N" %JNFOTJPOT)Y8Y% JOYJOYJONNYNNYNN 4UBOEBSET 6--JTUFE"4PMJE4UBUF$POUSPMT'PS"QQMJBODFT "QQMJBODFT '$$1BSU$MBTT#%JHJUBM%FWJDFGPS)PNFPS0GýDF6TF ** For additional ordering information see technical section page 135 Catalog Number Description 4-$3'6%øøøø 4-$%-6% 1MVH"EBQUPS$IBOOFM3FMBZ" 1MVH"EBQUPS$IBOOFM-FBEJOH&EHF8 110 C-BUSTM WIRELESS CONTROLS + WIRELESS CONTROLS C-BusTM RF Wireless Controls RF Remote Control 5IF$#VT5.8JSFMFTT3'3FNPUF$POUSPMQSPWJEFTDPOUSPMPG$#VT8JSFMFTT3' $POUSPM4ZTUFNTLFZQBETBOEPSQMVHBEBQUFSVOJUT 6QUPUFOTFQBSBUFLFZQBEPSQMVHBEBQUFSVOJUCVUUPOTDBOCFDPOUSPMMFECZUIF SFNPUFDPOUSPM5IFCVUUPOTDBOCFPOWBSJPVTVOJUTPOEJGGFSFOUXJSFMFTTOFUXPSLT "TJOHMFCVUUPOPOBLFZQBEPSQMVHBEBQUFSVOJUDBOCFDPOUSPMMFECZVQUPUXP3' remote controls. $#VT8JSFMFTT3' 3FNPUF$POUSPM Product Features Technical Information 4VQQMZ7PMUBHF Y"""CBUUFSJFT Radio Frequency .)[ 5SBOTNJUUJOH1PXFS N8 5ZQJDBMSBOHF SBOHFEFQFOETPOCVJMEJOH DPOTUSVDUJPOBOEUIFQSPYJNJUZ UPEFOTFPSNFUBMMJDPCKFDUT 8PPEGSBNFCSJDLWFOFFSDPOTUSVDUJPO UPGFFUUPN #SJDLTUPOFPSTUFFMGSBNFDPOTUSVDUJPO UPGFFUUPN Steel reinforced concrete construction UPGFFUUPN .BYJNVN3BOHFPQFOBJS %JNFOTJPOT GUN YYJONNYNNYNN 0QUJPO EBSLOFTTIBTiJHOPSFýSTUCVUUPOQSFTTwPQUJPO 0QFSBUJOH&OWJSPONFOU 5FNQ0'UP0'0$UP0$ 3)OPODPOEFOTJOH 4UBOEBSET '$$1BSU$MBTT#EJHJUBMEFWJDFGPSIPNFPSPGýDFVTF Remote Control Holder %JNFOTJPOT YYJONNYNNYNN .PVOUJOH$FOUFST .PVOUJOH4DSFX4J[F UPJOUPNN YJONNYNN 8BMM"ODIPS YJONNYNN *For Diagram see technical section page 136 111 Catalog Number Description 4-$59#% $#VT8JSFMFTT3')BOEIFME3FNPUF$POUSPM t$PNQBUJCMFXJUIBMM$#VT3'LFZQBET tTFQBSBUFQSPHSBNNBCMFCVUUPOT t"MM0''CVUUPO t%JNVQEPXOCVUUPO t-$%TDSFFOXCVUUPOJOEJDBUPSBOEAMFBSO NPEFJOEJDBUPS t8BMMNPVOUBCMFIPMEFSJODMVEFE t5XP"""CBUUFSJFTJODMVEFE C-BUSTM WIRELESS CONTROLS + WIRELESS CONTROLS C-BusTM RF Wireless Controls Wireless Gateway 5IF$#VT5.3'(BUFXBZQSPWJEFTB$#VTQSPUPDPMDPNNVOJDBUJPOCSJEHFCFUXFFOB TJOHMF$#VT3'XJSFMFTTTZTUFNBOEBTJOHMF$#VTXJSFEOFUXPSL #PUIUIFXJSFEBOEXJSFMFTT$#VTOFUXPSLUZQFTVTFUIFTBNFQSPUPDPMDPNNBOET UIVTCZVTJOHUIF(BUFXBZB$#VT3'XJSFMFTTBOEXJSFEOFUXPSLDBODPNNVOJDBUF BOETFBNMFTTMZJOUFSBDUXJUIFBDIPUIFS5IJTBMMPXTBXJSFMFTT$#VTDPOUSPMTZTUFN third party functionality, with the ability to control audio, blinds, irrigation systems, etc. 5IF3'(BUFXBZDBOCFJOTUBMMFEIPSJ[POUBMMZCZVTJOHUIFBEIFTJWFGFFUJODMVEFE PS WFSUJDBMMZVTJOHUIFLFZIPMFDVUPVUTPOUIFCBTFPGUIFVOJU 8JSFMFTT(BUFXBZ Technical Information $#VT5.4VQQMZ7PMUBHF UP7%$N" 3''SFRVFODZ .I[ 5SBOTNJUUJOH1PXFS N8 5ZQJDBM3BOHF SBOHFEFQFOETPOCVJMEJOH DPOTUSVDUJPOBOEQSPYJNJUZUP dense or metallic objects) UPGUUPN JOCVJMEJOHTXJUIUJNCFS GSBNFCSJDLWFOFFSDPOTUSVDUJPO UPGUUPN JOCVJMEJOHTXJUICSJDL stone, or steel frame construction UPGUUPN JOCVJMEJOHTXJUITUFFM reinforced concrete construction .BYJNVN3BOHF GUN JOPQFOBJS 4UBUVT*OEJDBUPS$PMPS Product Features t&BTZUPQSPHSBN t$POUSPMCFUXFFOXJSFEBOEXJSFMFTT $#VTOFUXPSLT t.PVOUIPSJ[POUBMMZPSWFSUJDBMMZ t&OBCMFUIJSEQBSUZPQFSBCJMJUZCZDPOOFDUJOH BXJSFMFTTOFUXPSLUPBXJSFEOFUXPSL t"EKVTUBCMFBOUFOOBGPSDMFBSSFDFQUJPO t4JNQMF$BUDPOOFDUJPOUP$#VTXJSFE system t$#VTTZTUFNDMPDL 0GG/P$#VTDPOOFDUJPOPSJOTVGýDJFOUQPXFS 4MPX'MBTIJOHo/PSNBMDPOOFDUJPOUP$#VTOFUXPSL 2VJDL'MBTIJOH$POýSNTUIBUUIF3'(BUFXBZ IBTCFFOMJOLFEUPUIF3'8JSFMFTTTZTUFN 0QFSBUJOH5FNQFSBUVSF3BOHF UP0'UP0$ 5JNFST 0QFSBUJOH)VNJEJUZ3BOHF 5JNFUP3) %JNFOTJPOT8Y)Y% JOYJOYJONNYNNYNN 8FJHIU P[H .PVOUJOH$FOUFST JONN 8FJHIU P[H 4UBOEBSET 6-&OFSHZ.BOBHFNFOU&RVJQNFOU $4"$/P4JHOBM&RVJQNFOU '$$1BSU$MBTT#%JHJUBM%FWJDFGPS)PNF or Office Use *For Diagram see technical section page 136 Catalog Number 4-$8$(% Description 3'(BUFXBZ 112 C-BUSTM WIRELESS CONTROLS + TECHNICAL SECTION C-BusTM Neo™ Decorator Style RF Keypads 1.456 in. 37mm 3.0 in. 76 mm 1.69 in. 43 mm 2.76 in. 70 mm 4.57 in. 116 mm 0.28 in. 7 mm 'SPOUWJFXPGLFZQBEJODMVEJOHFYUFSOBMIFJHIU and width measurements of Faceplate 4JEFWJFXPGLFZQBEJODMVEJOHIFJHIUBOE depth requirements for insertion into wall 5PQWJFXPGLFZQBEJODMVEJOH depth of face plate C-BusTM SaturnTM Decorator Style RF Dimmers .35 in. 9 mm 2.99 in. 2.99 in. 0.98 in. 25 mm 76 76 mm mm 2.76 in. 2.76 in. 70 70 mm mm 4.57 in. 4.57 in. 116 mm 116 mm 1.65 in. 1.65 in. 42mm mm 42 2.87 in. 2.87 in. 73 mm 73 mm 1.456 in. 37mm .71 in. 'SPOUWJFXPGLFZQBEJODMVEJOHFYUFSOBM height and width measurements of case 18 mm 4JEFWJFXPGLFZQBEJODMVEJOHIFJHIUBOEEFQUI requirements for insertion into wall C-BusTM RF Wireless Controls Plug Adaptors 4.5 in. 1.7 in. 113 2.0 in. 5PQWJFXPGLFZQBETIPXJOHXJEUI C-BUSTM WIRELESS CONTROLS + TECHNICAL SECTION C-BusTM RF Wireless Controls RF Remote Control Dimensions for the RF Remote Holder Dimensions for the RF Remote Control 2.2 in. 55 mm 5.9 in. 149 mm 4.3 in. 108 mm 1.3 in. 33 mm 2.0 in. 52 mm 1.3 in. 33 mm C-BusTM RF Wireless Controls Wireless Gateway 4.10 in. 105 mm 5.9 in. 149 mm 'SPOUWJFXPG(BUFXBZ 4JEFWJFXPG(BUFXBZ 1.0 in. 26 mm 5PQWJFXPG(BUFXBZ 114 TM C-Bus 115 Software Introduction to C-BusTM Software 3FTJEFOUJBM$POUSPM 5IF$#VT)PNF(BUF4PGUXBSFQSPWJEFT SFTJEFOUJBMBQQMJDBUJPO1$DPOUSPMPGB$#VT $POUSPM4ZTUFN)PNF(BUFDBOCFBDDFTTFE GSPNBMPDBM1$PSSFNPUFMZWJBBO*OUFSOFU connection with a standard web browser. 5IF)PNF(BUFHSBQIJDBMVTFSJOUFSGBDFJT designed for simplicity of use and provides FBTZUPVTF.FOVBOE5BCCBTFEPQUJPOT 5IFJOUFSGBDFBMMPXTTFUVQPGNVMUJQMFVTFS pages and provides a way to easily navigate between the pages. $PNNFSDJBM$POUSPM 5IF$#VT® Schedule Plus Software provides a powerful and simple to use interface to a $#VTDPOUSPMTZTUFN4DIFEVMF1MVTQSPWJEFT control and monitoring of a commercial or JOEVTUSJBM$#VTTZTUFNGSPNB1$SVOOJOH UIF.JDSPTPGU®8JOEPXT® operating system. "DDFTTJTPCUBJOFEGSPNBMPDBM1$PSSFNPUFMZ via an Internet connection with a standard 8FC#SPXTFS 116 C-BUSTM SOFTWARE + SOFTWARE C-BusTM Software HomeGate 5IF$#VT5.)PNF(BUF4PGUXBSFQSPWJEFTSFTJEFOUJBMBQQMJDBUJPO1$DPOUSPMPGB$#VT $POUSPM4ZTUFN )PNF(BUFDBOCFBDDFTTFEGSPNBMPDBM1$PSSFNPUFMZWJBBO*OUFSOFUDPOOFDUJPO XJUIBTUBOEBSEXFCCSPXTFS5IF)PNF(BUFHSBQIJDBMVTFSJOUFSGBDFJTEFTJHOFEGPS TJNQMJDJUZPGVTFBOEQSPWJEFTFBTZUPVTF.FOVBOE5BCCBTFEPQUJPOT5IFJOUFSGBDF allows set-up of multiple user pages and provides a way to easily navigate between the QBHFT5IFVTFSBMTPIBTUIFBCJMJUZUPQBTTXPSEQSPUFDUJOEJWJEVBMQBHFTBTSFRVJSFE HomeGate Application Software USB )PNF(BUFEJTQMBZTHSBQIJDBMJUFNTPOVTFSQBHFTUPQFSGPSNB$#VTGVODUJPOXIFO QSFTTFE&YBNQMFTPGUIFTFJUFNTJODMVEFCVUUPOTTMJEFSTJOEJDBUPSTSFBMUJNFDMPDLT BOEEPXOMPBEFE+1&(PS#JUNBQ*NBHFT0CKFDUTDBOCFQMBDFEBOETJ[FEBTBVTFS SFRVJSFTBOEDBOCFEJTQMBZFEJOGVMMDPMPS)PNF(BUFBMTPSFQPSUTUIFTUBUFPGUIF$#VT HSPVQBEESFTTFTPOBOFUXPSLJOSFBMUJNFXJUIHSPVQBEESFTTFTSFQSFTFOUFECZUFYU PSJDPOTUIBUDIBOHFDPOEJUJPOEFQFOEJOHPOTUBUVT$VTUPNJDPOTDBOCFHFOFSBUFE UPSFQSFTFOUUIFWBSJPVTDPOUSPMTUBUFTBMUFSOBUJWFMZJDPOTGSPNUIFJDPOMJCSBSZQSPWJEFE XJUIUIFQBDLBHFDBOCFVTFE "TXFMMBTNBOVBMDPOUSPMBOENPOJUPSJOHPGB$#VTTZTUFNWJBB1$)PNF(BUFDBO BMTPCFVTFEUPDSFBUFBOEFEJUDPNQMFUF$#VTTDFOFTBOEJOJUJBUFSFBMUJNFCBTFE TDIFEVMFTPGFWFOUT5IFTPGUXBSFTVQQPSUTBQSPKFDUFEJUJOHNPEFGPSDVTUPNJ[JOHUIF VTFSJOUFSGBDFBOEBOPQFSBUJPONPEFXIFSFDMJDLJOHDPNQPOFOUTPOUIFTDSFFOXJMM execute the programmed actions. Product Features Technical Information 1MBUGPSN 8JOEPXT/5.&7JTUBBOE91 4FSWFS5FDIOPMPHZ $#VT$(BUF $POOFDUJPOT (SBQIJDBM0CKFDUT &UIFSOFU34 5FYUCVUUPOTTMJEFSTTIBQFTJNBHFTSFBMUJNFDMPDL $#VTUJNFSQFSDFOUBHFJOEJDBUPSMJHIUMFWFMUFNQFSBUVSF$#VTOFUXPSLWPMUBHF $PNQPOFOU1SPQFSUJFT (SBQIJDBM"TTPDJBUJPOT $#VTOFUXPSLQBSBNFUFSTQPTJUJPOTJ[FGPOUTUZMFBOEDPMPSUFYUBOEJNBHF BMJHONFOUTCPSEFSTTUSPLFCBDLHSPVOEDPMPSTIBEJOH $#VTDPNNBOEPOPGGSBNQ TDFOFBDUJWBUJPOTDFOFBDUJWBUJPOWJB $#VTTDFOFDPOUSPMMFSTQBHFMJOLTCBDLPOFQBHF operation over remote applications, exit simulation page 4DIFEVMFE&WFOUT &WFOU1SPQFSUJFT &YBNQMFPGB$VTUPNJ[FE)PNF(BUF4DSFFO6TJOH %PXOMPBEFE*NBHFBOE#VUUPOT $SFBUFEJTQMBZFEJUBOEQSJOU%BJMZXFFLMZXFFLEBZT XFFLFOETNPOUIMZBOEPODFPGG 4FOE$#VTDPNNBOEPOPGGSBNQSBNQSBUF TFOEQVMTFE $#VTDPNNBOETTFUTDFOFTUJNFPGFWFOUDZDMFPGFWFOU Password Protection t4VQQPSUT.JDSPTPGU1MBUGPSNT7JTUBDPNQBUJCMF t4VQQPSUGPSCJUFODSZQUFETFDVSF*OUFSOFU connectivity or USB t$POOFDUJPOUP$#VTWJB&UIFSOFUPS34 t5XPPS5FO/FUXPSLTPGUXBSFMJDFOTFPQUJPOT t'VMMZGVODUJPOBMMPHJDFOHJOF t(SBQIJDBMDPNQPOFOUTVTFEUPJMMVTUSBUFBDUJPOT t4DIFEVMFEFWFOUTDBOCFDSFBUFEEJTQMBZFEFEJUFE QSJOUFEBOETDIFEVMFEEBJMZXFFLMZXFFLEBZT XFFLFOETBOENPOUIMZ t4PVOE'JMFT8"7 DBQBCJMJUZ t1BHFUFNQMBUFTBOEJNBHFMJCSBSZ t&WFOUMPH t5XPNPEFT/PSNBM0QFSBUJPOPS1SPKFDU&EJUJOH .PEFT t*OEJWJEVBMQBHFTDBOCFQBTTXPSEQSPUFDUFE t"QQMJDBUJPOTVQQPSUGPS)7"$BOE4FDVSJUZ Yes .PEFT /PSNBM1SPKFDU&EJUJOH Project Summary Yes &WFOU-PH :FT 1BHF5FNQMBUFT :FTJODMVEFE *NBHF-JCSBSZ :FTJODMVEFE 4PVOE 8"7ýMFDBQBCMF Catalog Number Description 4-$4%)( )PNF(BUFMJDFOTFLFZGPSOFUXPSLT 4-$4%)( )PNF(BUFMJDFOTFLFZGPSOFUXPSLT 4-$4%*/45 )PNF(BUFJOTUBMMFS,FZ * Installer key allows installers to create/commission projects using HomeGate software. This code key is time restricted and allows the software to operate in ‘normal’ mode for anywhere between 48 to 72 hours per use (the software then returns to evaluation/demo mode). NOTE: The installer code key will also be compatible with future software releases 117 C-BUSTM SOFTWARE + SOFTWARE C-BusTM Software Schedule Plus 5IF$#VT5. Schedule Plus Software provides a powerful and simple to use interface to B$#VTDPOUSPMTZTUFN4DIFEVMF1MVTQSPWJEFTDPOUSPMBOENPOJUPSJOHPGBDPNNFSDJBM PSJOEVTUSJBM$#VTTZTUFNGSPNB1$SVOOJOHUIF.JDSPTPGU®8JOEPXT® operating TZTUFN"DDFTTJTPCUBJOFEGSPNBMPDBM1$PSSFNPUFMZWJBBO*OUFSOFUDPOOFDUJPOXJUIB TUBOEBSE8FC#SPXTFS 4DIFEVMF1MVTEJTQMBZTHSBQIJDBMJUFNTPOVTFSQBHFTXJUITJNQMF.FOVBOE5BC CBTFEPQUJPOT(SBQIJDJUFNTDBOCFQSPHSBNNFEUPQFSGPSN$#VTGVODUJPOTXIFO pressed. Examples of the type of items that can appear on Schedule Plus pages include CVUUPOTTMJEFSTJOEJDBUPSTSFBMUJNFDMPDLT+1&(*NBHFTBOE#JUNBQ*NBHFT5IFTF can be placed and sized as a user requires and can be displayed in full color. Schedule 1MVTBMTPSFQPSUTUIFTUBUFPGUIF$#VTHSPVQBEESFTTFTPOBOFUXPSLJOSFBMUJNF with group addresses represented by text or icons that change condition depending POTUBUVT$VTUPNJDPOTDBOCFHFOFSBUFEUPSFQSFTFOUUIFWBSJPVTDPOUSPMTUBUFT BMUFSOBUJWFMZJDPOTGSPNUIFJDPOMJCSBSZQSPWJEFEXJUIUIFQBDLBHFDBOCFVTFE "TXFMMBTNBOVBMDPOUSPMBOENPOJUPSJOHPGB$#VTTZTUFN4DIFEVMF1MVTDBOBMTPCF VTFEUPDSFBUFBOEFEJUDPNQMFUF$#VTTDFOFTBOEJOJUJBUFSFBMUJNFCBTFETDIFEVMFT PGFWFOUT5IFTPGUXBSFTVQQPSUTBQSPKFDUFEJUJOHNPEFGPSDVTUPNJ[JOHUIFVTFS JOUFSGBDFBOEBOPQFSBUJPONPEFXIFSFDMJDLJOHDPNQPOFOUTPOUIFTDSFFOXJMMFYFDVUF the programmed actions. Enhanced scheduling includes support for monitoring load run times, load power and energy consumed. Technical Information 1MBUGPSN 8JOEPXT/5.&7JTUBBOE91 $#VT$(BUF $POOFDUJPOT (SBQIJDBM0CKFDUT &UIFSOFU34 5FYUCVUUPOTTMJEFSTTIBQFTJNBHFTSFBMUJNFDMPDL $#VTUJNFSQFSDFOUBHFJOEJDBUPSMJHIUMFWFMUFNQFSBUVSF$#VTOFUXPSLWPMUBHF $PNQPOFOU1SPQFSUJFT (SBQIJDBM"TTPDJBUJPOT $#VTOFUXPSLQBSBNFUFSTQPTJUJPOTJ[FGPOUTUZMFBOEDPMPSUFYUBOEJNBHF BMJHONFOUTCPSEFSTTUSPLFCBDLHSPVOEDPMPSTIBEJOH $#VTDPNNBOEPOPGGSBNQ TDFOFBDUJWBUJPOTDFOFBDUJWBUJPOWJB $#VTTDFOFDPOUSPMMFSTQBHFMJOLTCBDLPOFQBHF operation over remote applications, exit simulation page &WFOU1SPQFSUJFT $SFBUFEJTQMBZFEJUBOEQSJOU%BJMZXFFLMZXFFLEBZT XFFLFOETNPOUIMZBOEPODFPGG 4FOE$#VTDPNNBOEPOPGGSBNQSBNQSBUF TFOEQVMTFE $#VTDPNNBOETTFUTDFOFTUJNFPGFWFOUDZDMFPGFWFOU Password Protection Yes .PEFT &YBNQMFPGB4DIFEVMF1MVT4PGUXBSF%JTQMBZ4DSFFO Product Features 4FSWFS5FDIOPMPHZ 4DIFEVMFE&WFOUT Schedule Plus Application Software USB /PSNBM1SPKFDU&EJUJOH Project Summary t4VQQPSUT.JDSPTPGU1MBUGPSNT7JTUBDPNQBUJCMF t4VQQPSUTCJUFODSZQUFEJOUFSOFUDPOOFDUJWJUZ t"VUPNBUJDQSPKFDUFSSPSDIFDLJOHBOESFQPSUJOH t$POOFDUJPOUP$#VTWJB&UIFSOFUPS34 t5XPUFOBOEVOMJNJUFEOFUXPSLTPGUXBSFMJDFODF LFZPQUJPOT t'VMMZGVODUJPOBMMPHJDFOHJOF t(SBQIJDBMDPNQPOFOUTVTFEUPJMMVTUSBUFBDUJPOT t4DIFEVMFEFWFOUTDBOCFDSFBUFEEJTQMBZFE FEJUFEQSJOUFEBOETDIFEVMFEEBJMZXFFLMZ XFFLEBZTXFFLFOETBOENPOUIMZ t.POJUPSJOHPGMPBESVOUJNFTMPBEQPXFSBOE energy consumed t1BHFUFNQMBUFTBOEJNBHFMJCSBSZ t&WFOUMPH t5XPNPEFT/PSNBM0QFSBUJPOPS1SPKFDU &EJUJOH.PEFT t*OEJWJEVBMQBHFTDBOCFQBTTXPSEQSPUFDUFE t"QQMJDBUJPOTVQQPSUGPS)7"$BOE4FDVSJUZ Yes &WFOU-PH :FT 1BHF5FNQMBUFT :FTJODMVEFE *NBHF-JCSBSZ :FTJODMVEFE 4PVOE 8"7ýMFDBQBCMF Catalog Number Description 4-$4%41 4DIFEVMF1MVTMJDFOTFLFZGPSOFUXPSLT 4-$4%41 4DIFEVMF1MVTMJDFOTFLFZGPSOFUXPSLT 4-$4%416 4DIFEVMF1MVTMJDFOTFLFZGPSVOMJNJUFEOFUXPSLT 4-$4%*/45 4DIFEVMF1MVTJOTUBMMFS,FZ * Installer key allows installers to create/commission projects using HomeGate software. This code key is time restricted and allows the software to operate in ‘normal’ mode for anywhere between 48 to 72 hours per use (the software then returns to evaluation/demo mode). NOTE: The installer code key will also be compatible with future software releases 118 Design guide 119 Design guide contents Introduction Capabilities Specifications a. Overview a. Dimming b. Multi-scene control c. Daylighting control a. Programming principles b. Addressing conventions i. Group addressing ii. Area addressing iii. Application addressing iv. Network addressing c. C-Bus wiring i. Network topology ii. Network size iii. Network cable iv. Power supplies v. Network burden vi. System clock vii. Connecting to the C-Bus network Planning and design Installation and Commissioning a. Space considerations b. Occupant control needs (space-based) c. Lighting considerations d. Occupancy considerations e. Energy code considerations f. Map system requirements (space worksheet) g. Design project i. Lighting ii. Space control iii. Control points iv. Input unit selection v. Sensor selection and placement vi. Output unit selection vii. Output unit packaging viii. Output unit placement ix. Bill of material x. Finished design a. Order C-Bus units b. Mark units with part name c. Build database and mark plans d. Configure unit addresses e. Send configured units to site f. Finish development of database i. Functional ii. Relational g. Download configuration into installed C-Bus network h. Commission (troubleshoot) 120 C-BUSTM LIGHTING CONTROL + DESIGN GUIDE Contents I. Introduction IV. Planning and Design a. Overview a. Space Considerations b. Occupant Control Needs (Space-based) c. Lighting Considerations d. Occupancy Considerations e. Energy Code Considerations f. Map System Requirements (Space Worksheet) g. Design Project i. Lighting ii. Space Control iii. Control Points iv. Input Unit Selection v. Sensor Selection and Placement vi. Output Unit Selection vii. Output Unit Packaging viii. Output Unit Placement ix. Bill of Material x. Finished Design) II. Capabilities a. Dimming b. Multi-Scene Control c. Daylighting Control III. Specifications a. Programming Principles b. Addressing Conventions i. Group Addressing ii. Area Addressing iii. Application Addressing iv. Network Addressing c. C-Bus Wiring i. Network Topology ii. Network Size iii. Network Cable iv. Power Supplies v. Network Burden vi. System Clock vii. Connecting to the C-Bus Network 121 V. Installation & Commissioning a. Order C-Bus Units b. Mark Units with Part Name c. Build Database and Mark Plans d. Configure Unit Addresses e. Send Configured Units to Site f. Finish Development of Database i. Functional ii. Relational g. Download Configuration into Installed C-Bus Network h. Commission (troubleshoot) C-BUSTM LIGHTING CONTROL + DESIGN GUIDE Introduction -JHIUJOH$POUSPMGSPN4DIOFJEFS&MFDUSJDFNQMPZT$#VTOFUXPSLDPOUSPMGPSDPNNFSDJBMMJHIUJOH$PNQBSFEUPDPOWFOUJPOBMDPOUSPMTZTUFNT $#VTOFUXPSLDPOUSPMTSFEVDFJOTUBMMBUJPOUJNFTJNQMJGZMJHIUJOHDPOUSPMDJSDVJUTTBWFFOFSHZBOEBDIJFWFHSFBUFSGVODUJPOBMJUZ5IF$#VT OFUXPSLJTBEJTUSJCVUFEJOUFMMJHFODFOFUXPSLDPOUSPMTZTUFNJODPSQPSBUJOHNJDSPQSPDFTTPSCBTFEDPOUSPM&BDI$#VTEFWJDFGFBUVSFTBOJOUFHSBM microcontroller to achieve a robust and reliable distributed control system. Once installed, the installer programs the operating variables and control SFMBUJPOTIJQTCFUXFFO$#VTEFWJDFTPOUIFOFUXPSL5IF$#VTOFUXPSLNBZCFTDBMFEUPýUBOZTJ[FQSPKFDUGSPNBTJOHMFDPOGFSFODFSPPNVQUP a very large building. Objective 5IJTHVJEFQSPWJEFTMJHIUJOHDPOUSPMEFTJHOFSTXJUIHVJEBODFOFFEFEUPEFTJHOBOEQMBO$#VTOFUXPSLDPOUSPMTZTUFNT"EEJUJPOBMTVQQPSUJT BWBJMBCMFUISPVHIUIF4DIOFJEFS&MFDUSJD-JHIUJOH$POUSPM5FDIOJDBM4VQQPSU5FBNBU Dimming %JNNJOHJTBDSJUJDBMQBSUPGUPEBZTMJHIUJOHDPOUSPMOFFET*OUIFQBTU manual dimming controls were used in offices, conference rooms, and classrooms to allow occupants to adjust light levels to meet the occupant needs or preferences. Now, more sophisticated lighting control systems employ dimming to provide multi-scene control, daylighting control and multi-level control in a variety of spaces and building types, from schools and offices to retail environments and warehouses, to save energy and provide more occupant-friendly control. $#VTJODMVEFTBWBSJFUZPGVOJUTUPBDIJFWFDPOUJOVPVTPSTUFQQFE EJNNJOHPGþVPSFTDFOUJODBOEFTDFOUBOEFWFO)*%MJHIUJOH *MMVTUSBUJPOPG%"-*/FUXPSL$POUSPM *MMVTUSBUJPOPG7%JNNJOH 122 C-BUSTM LIGHTING CONTROL + DESIGN GUIDE *MMVTUSBUJPOPG1IBTF"OHMF $POUSPMJO$POGFSFODF3PPN Multi-Scene Control 5IFQSFTTPGPOFCVUUPONBZDPOUSPMNBOZJOEJWJEVBMMPBET-PBETNBZCFUVSOFEPOPGGPSEJNNFEUPBQSFEFUFSNJOFEMFWFM%FQFOEJOHPO how a space is used, it may be necessary to have certain lights set to various levels for different functions. For example, a conference room NBZIBWFNVMUJQMFHSPVQTPGMJHIUJOHXIFSFPOFHSPVQJMMVNJOBUFTUIFUBCMFBOPUIFSHSPVQJMMVNJOBUFTUIFQFSJNFUFSJOUIFCBDLPGUIFSPPN BOEBOPUIFSHSPVQJMMVNJOBUFTUIFQFSJNFUFSJOUIFGSPOUPGUIFSPPN%VSJOHBNFFUJOHJUNBZCFEFTJSBCMFUPIBWFUIFMJHIUJOHPWFSUIFUBCMF TFUUPBOEIBWFUIFMJHIUJOHBSPVOEUIFQFSJNFUFSTFUUP5IJTDPVMECFBDDPNQMJTIFEXJUIBTJOHMFCVUUPOQSFTTUPDSFBUFUIF iNFFUJOHwTDFOF'PSQSFTFOUBUJPOTQFSJNFUFSMJHIUJOHJOUIFGSPOUPGUIFSPPNNBZCFUVSOFEPGGMJHIUJOHPWFSUIFUBCMFTFUBUBOE QFSJNFUFSMJHIUJOHJOUIFCBDLPGUIFSPPNTFUBU .VMUJ4DFOF$POUSPM Presentation (scene 1) Room Front = Off 3PPN3FBS 5BCMF'SPOU 5BCMF3FBS .FFUJOHTDFOF 3PPN'SPOU 3PPN3FBS 5BCMF'SPOU 5BCMF3FBS 6QUP TDFOFTXJUI CVUUPOLFZQBEPS%-5 123 C-BUSTM LIGHTING CONTROL Daylighting Control %BZMJHIUJOHDPOUSPMNBZCFVTFEUPSFEVDFBSUJýDJBM lighting of interior spaces when those spaces receive BEFRVBUFOBUVSBMMJHIUGSPNXJOEPXTPSTLZMJHIUT %BZMJHIUJOHDPOUSPMTBSFDPNNPOMZJOTUBMMFEJO $BMJGPSOJBXIFSFUIFTUBUFTCVJMEJOHDPEF5JUMF requires the use of daylighting controls in daylit spaces. %BZMJHIUJOHDPOUSPMNBZCFVTFEUPTBWFFOFSHZJO schools, offices, warehouses, and even retail spaces. .PSFBOENPSFCVJMEJOHTFTQFDJBMMZCJHCPYSFUBJMBOE TDIPPMTBSFUBLJOHBEWBOUBHFPGOBUVSBMTVOMJHIUUP JMMVNJOBUFJOUFSJPSTQBDFT$#VTMJHIUMFWFMTFOTPSTBSF easily configured to provide daylighting control utilizing relays for stepped dimming function or dimmer units for continuous dimming. + DESIGN GUIDE :,1'2:6 &%XV 0XOWL6HQVRU &%XV 0XOWL6HQVRU '$</,7$5($ &%XV &%XV =RQH 5HOD\ &K =RQH =RQH 'D\OLW 'D\OLW $UHD $UHD 'LPPHU 'LPPHU &K &K =RQH 5HOD\ &K 9$& 32:(5 6833/< &+ 5(/$< =21( '$</,7$5($ =21( '$</,7$5($ &+ 9 ',00(5 &%XV &%XV 0XOWL6HQVRUV =RQH 'D\OLW $UHD =RQH 'D\OLW $UHD *MMVTUSBUJPOPG%BZMJHIUJOH$POUSPM 124 C-BUSTM LIGHTING CONTROL + DESIGN GUIDE Specifications Programming Principles "MM$#VT5. devices require programming, with the exception of power supplies. Programming is BDIJFWFEXJUIQSPQSJFUBSZTPGUXBSFVTJOHB1$6OJU programming is performed to achieve the following PCKFDUJWFT t$SFBUFBOEEFýOFVOJUTPOUIF$#VTOFUXPSL t*EFOUJGZFBDIVOJUVTJOHUIF$#VTBEESFTTJOH convention t$SFBUFEFýOFBOEFEJUDPOUSPMSFMBUJPOTIJQT between inputs and outputs t&EJUVOJUPQFSBUJOHQBSBNFUFST 5IFPQFSBUJOHQBSBNFUFSTWBSZGSPNVOJUUPVOJU depending on its type. Keypad Functions 5JNFS'VODUJPOT %JNNJOH'VODUJPOT 5PHHMFPOPGG $POUSPM 1SFTFU-FWFMT $VTUPN0UIFS'VODUJPOT 4DFOFT.VMUJQMFMPDBUJPODPOUSPM t0VUQVU4XJUDIJOH-PHJD"TTJHONFOUT t1PXFS0VUBHF3FDPWFSZ4UBUVT t1PXFS6Q4FRVFODFT t%JNNJOH3BUFT t*OEJDBUPS0QUJPOT t4FOTPS4XJUDIJOH$POEJUJPOT t0WFSSJEF$POUSPMT&OBCMF%JTBCMF t&SSPS4UBUVT0QUJPOT C-Bus Installation Software version 2.0 Parameter Format Example 130+&$5/".& BMQIBOVNFSJDDIBSBDUFST 0''*$& /&5803, BMQIBOVNFSJDDIBSBDUFST 0GýDF/FUXPSL 6/*5 5ISFFEJHJUEFDJNBMOVNCFS OR OR 1"35/".& 5XPEJHJUIFYBEFDJNBMOVNCFS'' BMQIBOVNFSJDDIBSBDUFST ""# 3&-": "11-*$"5*0/ BMQIBOVNFSJDDIBSBDUFST -JHIUJOH "3&" BMQIBOVNFSJDDIBSBDUFST 'JSTU'MPPS0GýDFT (3061 BMQIBOVNFSJDDIBSBDUFST $POGFSFODF3N-JHIUT Addressing Conventions Once a preliminary list of hardware requirements has been created, planning of the programming requirements may begin. 5IF$#VTOFUXPSLVTFTBTJNQMFBEESFTTJOHTDIFNFUP JEFOUJGZVOJUTHSPVQTBSFBTBOEOFUXPSLT5IFQVSQPTFPGFBDI parameter will be discussed in the next section. "MQIBOVNFSJD$IBSBDUFST -FHBM"MQIBOVNFSJD$IBSBDUFS4FUB[";AAA@ "MMEFTDSJQUJWFBEESFTTFTBDDFQUUIFBCPWFMFHBM characters. Other characters may be accepted, but are not recommended. Project Names and Part Names will force capital letters. *MMVTUSBUJPOPG(SPVQ"EESFTTJOH )FYBEFDJNBM4ZNCPMT )FYBEFDJNBM4ZNCPM4FU"#$%&' "UBQIZTJDBMMFWFMUIFQSPHSBNNJOHJOGPSNBUJPOEPXOMPBEFEUP$#VT5.6OJUTDPOTJTUTPGBUXPEJHJUIFYBEFDJNBMOVNCFS SFQSFTFOUFECFBDPNCJOBUJPOPGUIFBCPWFTZNCPMT7BMJEBEESFTTFTJODMVEF"#'&&5IFEFTDSJQUJWFBEESFTTJOHJTOPUEPXOMPBEFE 5IJTJOGPSNBUJPOJTTUPSFEJOBEBUBCBTFPOZPVS1$"QSPHSBNNFE$#VTOFUXPSLDBOCFTDBOOFEVTJOHUIF$#VT*OTUBMMBUJPO4PGUXBSF*G B7FSTJPO1SPKFDU%BUBCBTFIBTOPUCFFOEFýOFECZUIFVTFSUIFTPGUXBSFXJMMVTFUIFIFYBEFDJNBMBEESFTTJOHVQMPBEFEUPSFQSFTFOUBMM VOLOPXOBEESFTTJOH6TFSTTIPVMEOPUFUIBUUIFTFIFYBEFDJNBMBEESFTTFTBSFBVUPNBUJDBMMZBTTJHOFE5IF1SPKFDUBOE5PQPMPHZ.BOBHFST may be used to reference or manipulate hexadecimal address as required. (SPVQ"EESFTTJOH 5IF(SPVQ"EESFTTJTVTVBMMZSFMBUFEUPUIFMPBEQIZTJDBMMZDPOOFDUFEUPUIFUFSNJOBMPGUIFPVUQVUVOJU5IFSFGPSFUIFHSPVQBEESFTT TIPVMEBDDVSBUFMZEFTDSJCFUIFMPBECFJOHDPOUSPMMFE5ZQJDBMMZOVNFSJDBMEFTJHOBUPSTBSFVTFEUPEFTDSJCFMJHIUJOHDJSDVJUT6QUP HSPVQBEESFTTFTNBZCFEFýOFEPOBTJOHMFOFUXPSLMFTTBOZEFýOFEBSFBBEESFTTFT7BMJEHSPVQTJODMVEF0GýDF-JHIUT)BMM-JHIUT -#"-5IFEFGBVMUHSPVQJTiVOVTFEw 125 C-BUSTM LIGHTING CONTROL + DESIGN GUIDE Area Addressing 5IFBSFBBEESFTTJTBDPOWFOJFOUNFUIPEPGBEESFTTJOHNVMUJQMFPVUQVUDIBOOFMTDPMMFDUJWFMZ-BSHFBSFBTDPOTJTUJOHPGNBOZ$#VT5. output units NBZCFDPOUSPMMFEGSPNBTJOHMFQPJOUPOUIF$#VTOFUXPSL5IFBSFBBEESFTTJTVTFEJOUIFHSPVQBEESFTTýFMEUPBDIJFWFDPOUSPM *MMVTUSBUJPOPG"SFB"EESFTTJOH &BDI$#VTJOQVUBOEPVUQVUEFWJDFJOBDPOUSPMBSFBNVTUCFBTTJHOFEUIFTBNFBSFBBEESFTT5IFBSFBBEESFTTNVTUCFVOJRVFBOENVTUOPU CFSFQFBUFEBTBHSPVQBEESFTTJOUIBU$#VTOFUXPSL6QUPBSFBTNBZCFEFýOFEMFTTUIFOVNCFSPGEFýOFEHSPVQT 126 C-BUSTM LIGHTING CONTROL + DESIGN GUIDE Application Addressing "QQMJDBUJPOTBSFVTFEUPEJWJEFUIF$#VTOFUXPSLJOUPJOEFQFOEFOUGVODUJPOBMTZTUFNT"MMHSPVQBEESFTTFTJOBOZVOJUBSFBTTPDJBUFEXJUI UIBUVOJUTBQQMJDBUJPOTBOEDPNNBOETJTTVFECZB$#VTJOQVUEFWJDFXJMMBGGFDUPOMZPVUQVUEFWJDFTXJUINBUDIJOHBQQMJDBUJPOTBOEHSPVQ BEESFTTFT6QUPBQQMJDBUJPOBEESFTTFTNBZCFVTFEPOBTJOHMF$#VTOFUXPSL#ZEFGBVMUýWFBQQMJDBUJPOTBSFEFýOFE&OBCMF$POUSPM )FBUJOH-FHBDZ -JHIUJOH5FMFQIPOZBOE5SJHHFS$POUSPM0UIFSBQQMJDBUJPOTNBZCFEFýOFEBTOFFEFE'PSFYBNQMFJOBNVMUJTUPSJFE CVJMEJOHJUNBZCFEFTJSBCMFUPIBWFBTFQBSBUFBQQMJDBUJPOGPSFBDIþPPSUPTBUJTGZUIFOFFEUPIBWFNPSFUIBOHSPVQBEESFTTFTPOUIF OFUXPSLPSUPBMMPXUIFTBNFHSPVQBEESFTTFTUPCFVTFEPWFSBOEPWFSFH0''*$&.&/4$0/'FUD *OUIJTDBTFEFýOFE BQQMJDBUJPOTNJHIUCF-JHIUJOH-JHIUJOHFUD *MMVTUSBUJPOPG"QQMJDBUJPO"EESFTTJOH 8IFSF-JHIUJOHBOE-JHIUJOHBSF4FQBSBUF"QQMJDBUJPOT 127 C-BUSTM LIGHTING CONTROL + DESIGN GUIDE Network Addressing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i'JSTU'MPPSwi.Z)PVTFwi.PWJF5IFBUSFwPSi#VJMEJOH"w6QUPVOJRVFOFUXPSLTNBZCF DPOOFDUFEUPHFUIFSVTJOH$#VT/FUXPSL#SJEHFTBTTIPXO 'PSMBSHFJOTUBMMBUJPOTXIFSFSFBMUJNFSFTQPOTFJTSFRVJSFEGSPNBDFOUSBMDPOUSPMB$#VT&UIFSOFU/FUXPSL*OUFSGBDFNBZCFVTFEUPDPOOFDU NVMUJQMF$#VTOFUXPSLTUPHFUIFSVTJOHBDPNNPO&UIFSOFUCBDLCPOF5IF$#VT&UIFSOFU/FUXPSL*OUFSGBDFJTB#BTF5&UIFSOFU compliant device. 128 C-BUSTM LIGHTING CONTROL + DESIGN GUIDE C-BusTM Wiring Rules 4DIOFJEFS&MFDUSJD$#VTJODPSQPSBUFTBEJTUSJCVUFEJOUFMMJHFODFMJHIUJOHDPOUSPMTZTUFNUIBUFNQMPZTBMPXWPMUBHFOFUXPSLPGJOUFMMJHFOUJOQVUPVUQVU BOEOFUXPSLDPNNVOJDBUJPOVOJUTUPDPOUSPMMJOFSBUFEMPBET$#VTOFUXPSLDPNNVOJDBUJPOTJTBDIJFWFEVTJOHQSPQSJFUBSZ$#VTQSPUPDPMPWFSBO VOTIJFMEFEUXJTUFEQBJS-"/DBCMF$BU651 4PNFTJNQMFSVMFTTIPVMECFPCTFSWFEXIFOTQFDJGZJOHPSEFTJHOJOHB4DIOFJEFS&MFDUSJD$#VT lighting control system. /FUXPSL5PQPMPHZ 4DIOFJEFS&MFDUSJD$#VTMJHIUJOHDPOUSPMTZTUFNJTDPNQSJTFEPG$#VTEFWJDFTJOUFSDPOOFDUFEVTJOH$BU651DBCMFUPBDIJFWFBUPQPMPHZGSFF $#VTOFUXPSL5IFMJHIUJOHDPOUSPMTZTUFNNBZJODPSQPSBUFBTJOHMFOFUXPSLPSNVMUJQMFOFUXPSLTUPPWFSDPNFUIFGPMMPXJOH$#VTOFUXPSLMJNJUBUJPOT t.BYJNVNDBCMFMFOHUI t"EESFTTJOHMJNJUBUJPOT t.BYJNVN"7%$QFSOFUXPSL t3FEVDFOFUXPSLSFTQPOTFUJNFSFEVDFMPDBMDPNNVOJDBUJPOTUSBGýD t"DDPNNPEBUFQIZTJDBMMBZPVUBOECVJMEJOHTUSVDUVSFOFUXPSLþPPS 8IFODPOOFDUJOHNVMUJQMFOFUXPSLTUPHFUIFSUIFGPMMPXJOHHVJEFMJOFTTIPVMECFPCTFSWFE t.JOJNJ[FUIFEFQUIPGUIFOFUXPSLUPQPMPHZGPSGBTUFSNPSFFGýDJFOUDPNNVOJDBUJPOT t%JTUSJCVUF$#VT6OJUTPOTFQBSBUFOFUXPSLTQSPQPSUJPOBMMZUPBWPJEDPNNVOJDBUJPOTBOEQPXFSTVQQMZQSPCMFNT'PSFYBNQMFJG $#VT6OJUTBSFSFRVJSFETQMJUJOUPUXPOFUXPSLTPG6OJUTFBDISBUIFSUIBO6OJUTPOUIFýSTUOFUXPSLBOE6OJUTPOUIFTFDPOE /FUXPSL4J[F 5IFNBYJNVNOVNCFSPG$#VTVOJUTPOBOZOFUXPSLTIBMMOPUFYDFFEVOJUT*GUIFMJHIUJOHDPOUSPMTZTUFNSFRVJSFTNPSFUIBOVOJUTBO BEEJUJPOBMOFUXPSLNBZCFDPOOFDUFEUPUIFýSTUOFUXPSLUISPVHIB$#VT/FUXPSL#SJEHFUPBMMPXDPNNVOJDBUJPOTCFUXFFOOFUXPSLT t.BYJNVNPG$#VTVOJUTQFSOFUXPSL t.BYJNVNPGOFUXPSLTQFSTZTUFN t/PNPSFUIBO%-5LFZQBETPOPOFOFUXPSLCFDBVTFPGBEWBODFEPQFSBUJPOT /FUXPSL$BCMF .BYJNVNDBCMFMFOHUIJTEFUFSNJOFECZUIFJNQFEBODFPGUIFDBCMFVTFE5IFSFTJTUJWFBOEDBQBDJUJWFJNQFEBODFPGOFUXPSLDBCMFWBSJFTCBTFEPO UZQF'PS$BU651UIFNBYJNVNMFOHUIGPSSFMJBCMFDPNNVOJDBUJPOTJTGU t.BYJNVNGUPG$BU651DBCMFQFSOFUXPSL t$#VT/FUXPSL#SJEHFTTIPVMECFVTFEUPTQMJUBOFUXPSLJOUPUXPPSNPSFOFUXPSLTXIFOUIFUPUBMDBCMFMFOHUISFRVJSFEFYDFFETGU Power Supplies 5IF$#VT1PXFS4VQQMZBOE0VUQVUVOJUTXJUIJOUFHSBMQPXFSTVQQMZQSPWJEFMPXWPMUBHFQPXFSUP$#VTEFWJDFTPOUIFOFUXPSL7%$ $VSSFOU SFRVJSFEUPPQFSBUF$#VTEFWJDFTWBSJFTEFQFOEJOHPOUIFEFWJDF3FGFSUPJOTUBMMBUJPOJOTUSVDUJPOTGPSTQFDJýD$#VTEFWJDFTUPEFUFSNJOFDVSSFOU SFRVJSFNFOUT&BDI$#VT1PXFS4VQQMZTVQQMJFTVQUPN"BOE$#VT0VUQVUVOJUTXJUIJOUFHSBMQPXFSTVQQMZXJMMTVQQMZVQUPN""EEJUJPOBM $#VT1PXFS4VQQMJFTNBZCFBEEFEUPNBJOUBJOPQUJNVNOFUXPSLWPMUBHFPG7%$%JTUSJCVUFQPXFSTVQQMJFTFWFOMZPOUIFOFUXPSLUPFWFOMZ EJTUSJCVUFWPMUBHFESPQ"MMQPXFSTVQQMJFTPOB$#VTOFUXPSLFWFOMZTIBSFUIFOFUXPSLMPBE5ZQJDBMMZOPNPSFUIBO 1PXFS4VQQMJFTTIPVME CFDPOOFDUFEUPBTJOHMFOFUXPSL8IFOVUJMJ[JOH0VUQVU6OJUTXJUIBOJOUFHSBMQPXFSTVQQMZSBUFEBUN"BNBYJNVNPG QPXFSTVQQMJFTJT BMMPXFE*OOPDBTFTIBMMUIFUPUBMBWBJMBCMFQPXFSFYDFFE"BU7%$ /FUXPSL#VSEFO "/FUXPSL#VSEFONVTUCFDPOOFDUFEUPB$#VTOFUXPSLUPBDIJFWFSFMJBCMFOFUXPSLDPNNVOJDBUJPOT5IF/FUXPSL#VSEFOJTDPNQSJTFEPGB DBQBDJUPSJOTFSJFTXJUIBSFTJTUPS0OFIBSEXBSF/FUXPSL#VSEFOJTJODMVEFEXJUIFBDI1$*OUFSGBDF1$* BOEUXPIBSEXBSF/FUXPSL#VSEFOTBSF JODMVEFEXJUIFBDI/FUXPSL#SJEHF5IF/FUXPSL#VSEFONBZCFTPGUXBSFFOBCMFEPONPTUPUIFS%*/SBJMNPVOUFE$#VTVOJUT0OFBOEPOMZPOF /FUXPSL#VSEFOJTSFRVJSFEGPSFBDI$#VTOFUXPSL*GNPSFUIBOPOF1$*PS/FUXPSL#SJEHFJTVTFEJOBOFUXPSLBMMCVUPOF/FUXPSL#VSEFOTIPVME CFEJTBCMFE'PSTZTUFNTXJUINVMUJQMFOFUXPSLTDPOOFDUFEUPHFUIFSWJB/FUXPSL#SJEHFTFBDIOFUXPSLXJUIJOUIF TZTUFNTIPVMEIBWFPOMZPOF/FUXPSL#VSEFODPOOFDUFEPSFOBCMFE 4ZTUFN$MPDL 5IF$#VTOFUXPSLSFRVJSFTPOFTZTUFNDMPDLTPVSDFUPPQFSBUF5IJTJTOPUBSFBMUJNFDMPDLIPXFWFSOFUXPSLDPNNVOJDBUJPOTBSFTZODISPOJ[FEUP UIJTTPVSDF5IF1$*BOE/FUXPSL#SJEHFVOJUTNBZCFVTFEUPQSPWJEFUIFTZTUFNDMPDL*GNPSFUIBOPOFPGUIFTFVOJUTJTQSFTFOUPOBOFUXPSLUIF OFUXPSLBVUPNBUJDBMMZEFUFSNJOFTXIJDIJTBDUJWF"NBYJNVNPGOFUXPSLDMPDLTTIPVMECFFOBCMFEPOB$#VTOFUXPSL $POOFDUJOHUPUIF$#VT/FUXPSL 5IF$#VTOFUXPSLJTEFTJHOFEUPPQFSBUFBU7%$5IF$#VTOFUXPSLJTPQUJDBMMZBOEPSHBMWBOJDBMMZJTPMBUFEGSPNMJOFWPMUBHFSBUFEDJSDVJUT 8IFOJOTUBMMJOH$#VTEFWJDFTUIFJOTUBMMFSTIPVMEBMXBZTGPMMPXBQQMJDBCMF/&$SFRVJSFNFOUTGPS$MBTTXJSJOH0QFSBUJOHBUBMPXWPMUBHFPG7%$ BMMPXTFMFDUSJDBMXPSLUPCFQFSGPSNFEPOUIF$#VTTJEFPGUIFTZTUFNXIJMFUIFTZTUFNJTQPXFSFEPO#FGPSFXPSLJOHPO$#VTOFUXPSLXJSJOH PSEFWJDFTMPDBUFEJOFODMPTVSFTXIFSF$MBTTXJSJOHJTQSFTFOUUVSOPGGQPXFSUP$MBTTDJSDVJUT5IF$#VTOFUXPSLJTTIPSUDJSDVJUQSPUFDUFEUP QSFWFOUEBNBHFUP$#VTEFWJDFTJGBTIPSUPDDVST5IF$#VTOFUXPSLXJMMOPUXPSLBTMPOHBTUIFOFUXPSLJTTIPSUFE$#VTEFWJDFTBSFDPOOFDUFE JOQBSBMMFMPOUIFOFUXPSL8IFUIFSUIFEFWJDFTBSFDPOOFDUFEVTJOHBEBJTZDIBJOUPQPMPHZBTUBSUPQPMPHZPSBDPNCJOBUJPOPGCPUIUPQPMPHJFTUIF EFWJDFTBSFBMXBZTDPOOFDUFEUPUIFOFUXPSLJOQBSBMMFMUPBDIJFWFBUPQPMPHZGSFFOFUXPSL)PNFSVOTBSFOPUSFDPNNFOEFEGPS$#VTOFUXPSLT 8IFODPOOFDUJOH$#VTEFWJDFTUPUIFOFUXPSLDBCMFUZQJDBMMZ$BU651 DBSFTIPVMECFUBLFOUPPCTFSWFQPMBSJUZSFRVJSFNFOUTDMFBSMZNBSLFEPO FBDIEFWJDF*UJTSFDPNNFOEFEUIBUJOTUBMMFSTVTFB$BU651 Correct wiring with the twist DBCMFXJUIBEJTUJOHVJTIBCMFDPMPSTVDIBTQJOLUPEJTUJOHVJTI being maintained between $#VTOFUXPSLDBCMFGSPNPUIFSOFUXPSLDBCMFXIJDINBZCF the two positive conductors QSFTFOU5IJTTJNQMJýFTMBUFSTFSWJDJOHPGUIFTZTUFNCZBMMPXJOH and their respective negative TFSWJDFQFSTPOOFMUPRVJDLMZJEFOUJGZ$#VTOFUXPSLDBCMFT conductors. 129 C-BUSTM LIGHTING CONTROL + DESIGN GUIDE Planning & Design 5IFNPTUJNQPSUBOUQIBTFPGBOZ4DIOFJEFS&MFDUSJD$#VT5.MJHIUJOHDPOUSPMQSPKFDUJTUIFQMBOOJOHBOEEFTJHOQIBTF"DPNQMFUFQMBOTUBSUTwith a HPPEVOEFSTUBOEJOHPGUIFMJHIUJOHDPOUSPMSFRVJSFNFOUT5PEFUFSNJOFXIBUJTSFRVJSFETUBSUCZBTLJOHUIFSJHIURVFTUJPOT 1. Where is lighting control required? 'PSFYBNQMFBTDIPPMNBZIBWFCPUIFYUFSJPSBOEJOUFSJPSMJHIUJOHUIBUSFRVJSFTDPOUSPM%FýOFUIFFYUFSJPSBOEJOUFSJPSMJHIUJOHUIBUSFRVJSFTDPOUSPMBOE segregate lighting by space. 2. How is each space used? 1SJWBUFPGýDFTXJUIJOBCVJMEJOHNBZTIBSFUIFTBNFMJHIUJOHDPOUSPMOFFET.FFUJOHBOEUSBJOJOHSPPNTNBZIBWFUIFTBNFMJHIUJOHDPOUSPMOFFET regardless of where these spaces fall within in a building. Functionally, a classroom differs from a restroom, so the entire site, including interior and exterior spaces, should be segregated based on the way the space is used. Similarly used spaces may share basic lighting control needs. 3. How will occupants want to control lighting to best utilize the space? $POTJEFSUIFOFFETPGUIFPDDVQBOU'PSFYBNQMFNVMUJTDFOFDPOUSPMNBZCFVTFEJODMBTTSPPNTDPOGFSFODFSPPNTBOEUSBJOJOHSPPNT3FTUSPPNT FNQMPZFFCSFBLSPPNTDPQJFSNBJMSPPNTBOEVUJMJUZDMPTFUTNBZPOMZSFRVJSFPDDVQBODZCBTFEDPOUSPM&YUFSJPSQBSLJOHMPUBOEQBUIXBZMJHIUJOHUIBUJT only needed at night may turn on and off based on time of day or sunrise and sunset. Private offices may require multi-scene of dimming controls, while PQFOPGýDFBSFBTNBZUVSOPOBOEPGGXJUIUJNFPGEBZTDIFEVMF8IJMFMJHIUJOHDPOUSPMTIPVMETBWFNPOFZJUTIPVMEBMTPFOIBODFUIFGVODUJPOBMJUZPG the space. 4. What type of lighting is to be controlled? If dimming is required, the type of lighting must be considered when selecting a dimmer. 5. When is lighting used? 5IJTJTJNQPSUBOU%VSJOHXPSLJOHIPVSTMJHIUJOHNBZCFVTFEEJGGFSFOUMZUIBOEVSJOHDMFBOJOHIPVSTGPSFYBNQMF$POTJEFSUIFMJHIUJOHVTFPOXFFLFOETBOEBGUFSIPVST-JHIUJOHNBZOPUCFVTFEEVSJOHIPMJEBZTTPJUJTJNQPSUBOUUPEFýOFXIFOMJHIUJOHDPOUSPMXJMMCFOFFEFEHJWJOHDPOTJEFSBUJPOUP holidays, inventory, shutdown and other events that may occur only once per year. 6. Is occupancy predictable? If an area has predictable days and hours of occupancy, it may be best to use a time of day schedule to control lighting in this area. For areas with less predictable occupancy patterns, occupancy-based control may be required, or a combination of control schemes may best meet the functional needs PGPDDVQBOUTBOEUIFFOFSHZFGýDJFODZOFFETPGCVJMEJOHPXOFS)BWJOHBDMFBSVOEFSTUBOEJOHPGUIFPDDVQBODZQBUUFSOTPGUIFCVJMEJOHXJMMIFMQUIF designer develop a lighting control system that is convenient for occupants and achieves energy efficiency. 7. What are the energy code requirements? %FQFOEJOHPOUIFFOFSHZDPEFTHPWFSOJOHBQBSUJDVMBSCVJMEJOHCBTFEPOJUTVTFJUTMPDBUJPOBOETJ[FUIFSFNBZCFTQFDJýDSFRVJSFNFOUTGPSMJHIUJOH control. Understanding the functional requirements as defined by the governing energy code is essential in the planning and design phase. Oversights at this point could result in costly changes later to bring lighting and lighting control systems into compliance with building codes. In most energy codes, lighting and lighting control requirements are intermingled, with some codes providing prescriptive lighting control requirements to bring otherwise noncomplying lighting systems into compliance. 8. What are the functional lighting control requirements for each space? "UUIJTQPJOUJOUIFQMBOOJOHQSPDFTTTUBSUEFýOJOHUIFGVODUJPOBMMJHIUJOHDPOUSPMOFFETGPSFBDITQBDF5IJTXJMMBJEUIFEFTJHOFSJOUIFQSPEVDUTFMFDUJPO QSPDFTT,FFQJONJOEUIBUTQBDFTUIBUBSFVTFEJOTJNJMBSXBZTNBZIBWFTJNJMBSPSJEFOUJDBMMJHIUJOHDPOUSPMOFFET(SPVQJOHTQBDFTCBTFEPOVTF NBZTJNQMJGZUIJTQSPDFTT-JHIUJOHGVODUJPOTUPDPOTJEFSBSF t%JNNJOHPSTXJUDIJOH t.BOVBMPSBVUPNBUJD t4DIFEVMFCBTFETIVUPGGPSPDDVQBODZCBTFETIVUPGG t.VUMJTDFOFPSNBOVBMEJNNJOHDPOUSPM t.BOVBMPSBVUPNBUJDEBZMJHIUJOHDPOUSPM t;POFTPSHSPVQT 9. Finally, what control functions are needed that include more than one space, zone, area or lighting group? 8JMMUIFPDDVQBOUXBOUBTJOHMFTXJUDIUPUVSOPOBOEPGGBMMMJHIUJOHJOUIFCVJMEJOH 8JMMUIFDMFBOJOHDSFXSFRVJSFTQFDJBMMJHIUJOHDPOUSPMTUPUVSOPO NVMUJQMFHSPVQTPS[POFT 8IBUUZQFPGBVUPNBUJDTIVUPGGTIBMMCFVTFEUPUVSOPGGMJHIUJOHJOUIFCVJMEJOHXIFOUIFCVJMEJOHJTVOPDDVQJFE 5IFQMBOOJOHQIBTFVTVBMMZJOWPMWFTNBQQJOHUIFTZTUFNSFRVJSFNFOUTBOEEFUFSNJOJOHUIFIBSEXBSFOFFETPGUIFTZTUFN5IPVHIUTIPVMECFHJWFO UPQMBDFNFOUBOEQBDLBHJOHPGIBSEXBSFQSPHSBNNJOHBOEDBCMJOHSFRVJSFNFOUT"TQMBOOJOHUSBOTJUJPOTJOUPEFTJHOJOHEPDVNFOUBUJPOPGUIFTZTUFN layout and functionality becomes more critical. 130 C-BUSTM LIGHTING CONTROL + DESIGN GUIDE Design Project 0GýDF$POGFSFODF3PPN%FTJHO1SPKFDU Space Lighting Offices 1-4 Tandem-Wired 3-Lamp Luminaires Neutral Line 0GýDFT5BOEFNXJSFEMBNQþVPSFTDFOUMVNJOBJSFT85 -JHIUJOHQPXFSEFOTJUZPG84'84' $POG3PPN3FDFTTFE8DPNQBDUþVPSFTDFOUMVNJOBJSFT 7QIBTFBOHMFEJNNJOHCBMMBTUQFSMVNJOBJSF Space control 0GýDFT.VMUJMFWFMDPOUSPM CVUUPOLFZQBEBMMPO"POPGG#POPGGBMMPGG Occupancy sensor shutoff $POG3PPN.VMUJ4DFOFDPOUSPMXJUIEJNNJOHDPOUSPM %ZOBNJD-BCFMJOH5FDIOPMPHZLFZQBECVUUPOTYQBHFT QSFTFUTDFOFTBMMPONFFUJOHQSFTFOUBUJPOMFDUVSFEJOJOHBMMPGG %JNVQEPXOUBCMFMJHIUT %JNVQEPXOSPPNMJHIUT Occupancy sensor shutoff Equipment Selection by Space 0GýDFT $#VT1*3¡PDDVQBODZTFOTPSQFSPGýDF #VUUPO/FP,FZQBEQFSPGýDF "SFMBZPVUQVUTQFSPGýDF $POG3PPN $#VT1*3¡PDDVQBODZTFOTPST %-5/FPLFZQBE "1IBTFBOHMFEJNNFSPVUQVUTQFSHSPVQ 131 $#VT*OQVU6OJU1MBDFNFOU 0GýDFT1MBDFLFZQBEJOXBMMCPYBEKBDFOUUPFOUSZ 1MBDFPDDVQBODZTFOTPSJODFJMJOHPWFSEFTLGPSCFTUDPWFSBHF $POG3PPN1MBDF%-5LFZQBEJOXBMMCPYBEKBDFOUUPFOUSZ - Place (2) occupancy sensors over table for best coverage C-BUSTM LIGHTING CONTROL + DESIGN GUIDE $POG3PPN $#VT1*3¡PDDVQBODZTFOTPST %-5/FP5.LFZQBE "1IBTFBOHMFEJNNFSPVUQVUTQFSHSPVQ $#VT*OQVU6OJU1MBDFNFOU 0GýDFT1MBDFLFZQBEJOXBMMCPYBEKBDFOUUPFOUSZ 1MBDFPDDVQBODZTFOTPSJODFJMJOHPWFSEFTLGPSCFTU coverage $POG3PPN1MBDF%-5LFZQBEJOXBMMCPYBEKBDFOUUPFOUSZ - Place (2) occupancy sensors over table for best coverage 1BDLBHJOHPG0VUQVU6OJUT 0GýDFT*OUPUBMPGýDFTSFRVJSF $I"SFMBZVOJUT 1SFQBDLBHFE"SFB-JHIUJOH1BOFM"-1 4-$;) 277V/20A Branch Ckt. Office 1 - A Office 1 - B Office 2 - A Office 2 - B Office 3 - A Office 3 - B Office 4 - A Office 4 - B "-1$I"3FMBZT4-$;) 132 C-BUSTM LIGHTING CONTROL + DESIGN GUIDE $POG3PPN*OUPUBMSFRVJSFT $I1IBTF"OHMF%JNNFSVOJUBOE $I" SFMBZVOJU$VTUPNQBDLBHFE"SFB-JHIUJOH1BOFMJO.FODMPTVSF To another ALP or Powerlink Device Router Unit 1 2 3 4 C-Bus 200mA C-Bus Power Supply included Voltage Free Relay Table Front Table Rear Room Front Room Rear To C-Bus keypads and sensors "-1XJUIY"3FMBZY"1IBTF"OHMF%JNNFS Bill of Material 133 $BUBMPH %FTDSJQUJPO 2UZ 4-$- 4-$;%5 4-$;) 4-$/-8& 4-$%-8& $#VT5.¡1*30DDVQBODZ4FOTPS $#VT"-1Y"3FMBZY"*ODBO%JNNFS7XJUI14 $#VT"-1Y"3FMBZ7XJUI14 $#VT#VUUPO4BUVSO5.,FZQBE8IJUF $#VT%-54BUVSO,FZQBE8IJUF C-BUSTM LIGHTING CONTROL + DESIGN GUIDE Finished Design $PNQMFUFE1SPKFDU-BZPVU Office 1 - A Table Front Office 1 - B Office 2 - A Table Rear Office 2 - B Office 3 - A Office 3 - B Room Front Office 4 - A Office 4 - B Room Rear *MMVTUSBUJPOPG%FTJHO1SPKFDU$POUSPMT Installation Once the design phase is complete, installation may begin. Several simple steps are typically followed to achieve a fast and accurate JOTUBMMBUJPOPGUIF$#VT5.OFUXPSLDPOUSPMTZTUFN *NQMFNFOUJOHQSPHSBNNJOHSFRVJSFNFOUTPGUIFEFTJHOPOB1$#VJMEBEBUBCBTFVTJOH$#VTTPGUXBSFUIBUJODMVEFTBMMUIF $#VTVOJUTVTFEJOUIFMJHIUJOHDPOUSPMTZTUFN&BDIVOJUJTBTTJHOFEBVOJUBEESFTT 6TJOHUIF1$BOEB1$*OUFSGBDFJOJUJBMJ[FBOEQSPHSBNFBDI$#VTEFWJDFPOFBUBUJNF&BDIEFWJDFJTBTTJHOFEBVOJUBEESFTT 1BDLBHJOHDBCMJOHBOEFMFDUSJDBMJOTUBMMBUJPOPGUIFIBSEXBSF 'JOBMJ[BUJPOBOEBEEJUJPOBMQSPHSBNNJOHPG$#VTEFWJDFTBTSFRVJSFE Commissioning 7FSJGZDPNQMJBODFXJUIUIFTQFDJýDBUJPOBOEDPNNJTTJPOUIFTZTUFN"EFTJHOSFWJFXNBZCFQFSGPSNFEBUUIJTQPJOUJOUIFQSPDFTT .PEJýDBUJPOTPSEFTJHODIBOHFTTFMEPNSFRVJSFJOTUBMMBUJPOPGBEEJUJPOBMIBSEXBSFUZQJDBMMZSFRVJSJOHPOMZQSPHSBNNJOHDIBOHFT 134 C-BUSTM LIGHTING CONTROL + DESIGN GUIDE One-line Diagram C-Bus™ home control solutions provide the utmost in capabilities, lower commissioning cost and greater customer appeal. C-Bus Din Rail Enclosure Load Center Professional Series Dimmer Wiser Home Controller User Interface Model Shown: 60M Variety of Sizes Available Web Tablet C-Bus DIN Rail Units Mobile Phone Input Units Auxiliary Input C-Bus DIN Rail Mounted Units provide a vast array of capabilities, scalable for virtually any size job, from a single room to an entire home. Dimmers, relays, timers, controllers and interface connections are all contained within C-Bus enclosures. General Input TV Screen Output Units Personal Computer Multi Channel Relays Phase Angle Dimmer 0-10 V Dimming Changeover Relay Network Units Power Supply 135 Color Touch Screen PC Interface Network Bridge Ethernet Gateway DALI Gateway Pascal Automation Controller Door Entry System C-BUSTM LIGHTING CONTROL + DESIGN GUIDE Schneider Electric Occupancy Sensors Occupancy sensors from Schneider Electric are the perfect solution for applications needing simple occupancy-based controls. Low-voltage ceiling- and wall-mounted occupancy sensors can be tied into C-Bus network using simple dry contact input. Wall Switch Ceiling Mount Fixture Mount Wall Mount C-Bus Network Typical Cat-5 Cable (Any Topology) Input Units Sensors (PIR/IR/Light Level) C-Bus Remote Control N Neo Decorator Keypad Neo™ Keypad Saturn™ Decorator Keypad Saturn Keypad Saturn DLT Keypad Neo DLT Keypad Bus Coupler (Dry Contact Connections) Telephone* RS-232 and Ethernet Connections Security, Blind/Shade Control, etc.* C-Bus Remote Control C l Touch Screens S Color Telephone Interface Unit Monochrome Touch Screens Integrated Systems HVAC C-Bus Wireless Gateway Thermostat C-Bus Audio Remote Control Multi Room C-Bus Matrix Switcher [8 Zone Output, IR (2), RCA (4) and Digital Input (1)] C-Bus Wireless Devices C-Bus Remote Control C-Bus Amplifiers (Desktop and Remote Mount) Consumer Audio Input Devices* Switches/Dimmers/Repeaters/ Multiple Location Devices/ Fan Controllers – All-in-one Keypad C-Bus Speakers (Indoor and Outdoor) Headphone* Air Conditioning* C-Bus Universal Remote Control Local Source Input* Plug Adaptor * Third-party Devices 136 13001300 SouthSouth Wolf Wolf RoadRoad • Des • Plaines, Des Plaines, Illinois Illinois 60018 60018 PHONE PHONE (847) (847) 827-9880 827-9880 • FAX• (847) FAX (847) 827-2925 827-2925 • junolightinggroup • junolightinggroup .com.com Regional Regional Offices Offi&ces Warehouses: & Warehouses: California, California, Georgia, Georgia, Illinois, Illinois, Indiana, Indiana, Pennsylvania, Pennsylvania, Texas, Texas, Ontario Ontario CN CN Products Products shown shown in this brochure in this brochure are covered are covered by U.S.by U.S. and international and international patentspatents pending. pending. SpecifiSpecifi cationscations subjectsubject to change to change withoutwithout notice.notice. ©2010©2010 JUNO JUNO LIGHTING, LIGHTING, LLC. LLC. C-Bus,C-Bus, Saturn Saturn and Neo andare Neo registered are registered trademarks trademarks of of Schneider Schneider ElectricElectric and/orand/or its affiliates its affiinliates the United in the United States States and/orand/or other countries. other countries. Other trademarks Other trademarks used herein used herein are are property property of theirofrespective their respective owners. owners. PrintedPrinted in U.S.A. in U.S.A. LIT-JLG-LC-PG LIT-JLG-LC-PG 5/10 5/10