123491_Lngfrd.3 6/10/08 4:34 PM Page 1 U L / C S A L I ST E D THE SIDING SOLUTION! TM PAI NTAB LE S I D I N G M O U NTI N G B OX E S , K ITS & B LO C KS F O R A LL S I D I N G T YP E S AN D F L AT S U R FAC E S Arlington New and Retro Siding Box Kits pages 6-9 One-Piece Fixture Box page 8 Retro Siding Box Kits pages 10-12 8081 Flangeless, w/ vertical box opening For standard light fixtures/devices • • • • 8081F With flanges, vertical box opening For standard light fixtures/devices • • • • 8081DBL Double height, flangeless, w/ vertical box opening For large light fixtures • • • • 8081FDBL Double height, with flanges, vertical box opening For large light fixtures • • • • 8082F With flanges, vertical box opening For fixtures/devices • • 8091F With flanges, deep vertical box opening For GFCIs, large devices, fixtures w/ ballast • • • • 8091FDBL Siding box kit w/ MEGA mounting plate For extra large fixtures, coach lamps • • • • 8141F One-piece fixture box For light fixtures and receptacles • • • • 8131 Kit with built-in electrical box For mounting standard fixtures on 1/4, 5/16" siding • 8141 Kit with built-in electrical box For mounting standard fixtures on 1/2" siding • 8141DBL Kit with built-in electrical box For mounting standard fixtures on 1/2" double siding • 8151 Kit with built-in electrical box For mounting standard fixtures on 5/8" siding • 8161 Kit with built-in electrical box For mounting standard fixtures on flat siding • 8171 Kit with built-in electrical box For mounting standard fixtures on dutch lap siding • 8100LP Oversized mounting cover converts Arlington’s standard siding boxes for larger surface mounting For large fixtures MEGA Siding Plates page 13 8100MLP Super MEGA siding plate converts Arlington’s standard siding boxes for larger surface mounting For extra large fixtures or coach lamps S Dutch Lap Siding Solutions from Arlington! 5/8" Page 2 1/2" 7:05 AM 1/4", 5/16" 6/6/08 Flat 123491_Lngfrd.2 T Y L I S H • U L L I S T E D For ID RIG NEWsiding electrical box with Retro Fixture Boxes with Threaded Openings weatherproof-in-use cover lap siding (also for stucco or textured surfaces). Non-metallic cover and base. Accepts most single-gang wiring devices and a GFCI cover plate. Box and white cover are textured/ paintable. UV- ■ standard GFCI face plate, (1) NM cable connector, block bushing with washer, and an in-place disposable mud cover. Installs in the wall, so less of it shows outside Also for stucco or textured surfaces in new construction... Mounting Bases for Meters and other Products pages 16-17 Install option: Cover is removable for easier device installation B 22 cu. in. Install NM cable connector and wire. Attach recessed IN BOX to block. Holes in flange allow stucco to bond firmly. Make a 3-1/4" x 5-1/2" hole in block. Pull wiring through plastic block bushing and opening in block. Block bushing mounts to interior side of block. A Install wiring device per manufacturer’s instructions, and local and National Electrical Codes. Retro Outlet Boxes with Threaded Openings Mounts to block C E NM cable Block bushing Note: Meets 2008 NEC Section 406-8; for the protection of exterior outlets which require the use of a weatherproof while-in-use cover for all outdoor 15 or 20 AMP receptacles. DBVM1C Washer Cable Completed installation with weatherproof-in-use cover. (Ready for assembly of furring strips and drywall) IN BOX and plastic block bushing mounted in concrete block CATALOG NUMBER UPC/DCI/NAED MFG #01 8997 Orientation/ Cover color UNIT PKG STD PKG DIM A DIM B DIM C DIM D DIM E 14315 14316 77608 77610 Vertical/Clear Vertical/White Horizontal/Clear Horizontal/White 1 1 1 1 4 4 4 4 9.058 9.058 7.012 7.012 7.012 7.012 9.058 9.058 5.160 5.160 5.160 5.160 1.805 1.805 1.805 1.805 3.222 3.222 3.222 3.222 Retro Weatherproof Electrical Boxes DBVM1C DBVM1W DBHM1C DBHM1W Arlington 24 20 T Y L I S H U L L I S T E D MM18 Plastic mounting base, 17-5/8" x 15-7/8" For mounting meters on siding • • • • DBHR151C , DBHR151W Clear/White • Horizontal IN BOX™ Weatherproof-in-use, recessed electrical box for Existing Vinyl Siding MM23 Plastic mounting base, 23" x 17-5/8" For mounting meters on siding • • • • DBHR171C , DBHR171W Clear/White • Horizontal IN BOX™ Weatherproof-in-use, recessed electrical box for Existing Vinyl Siding FS8131T Outlet box with threaded opening at top and bottom For use on 1/4" or 5/16" rigid siding • DBVR131C , DBVR131W Clear/White • Vertical IN BOX™ Weatherproof-in-use, recessed electrical box for Existing Vinyl Siding T A B L E • E • • • • • A S • • • • • DBHM1C , DBHM1W Clear/White • Horizontal IN BOX™ Weatherproof-in-use, recessed electrical box for NEW Rigid Siding, Stucco and Textured Surfaces • DBVR131 Vertical, DBHR131 Horizontal IN BOX™ Siding Profile Adapter Plate for Existing 1/4" or 5/16" Siding • DBVR151 Vertical, DBHR151 Horizontal IN BOX™ Siding Profile Adapter Plate for Existing 5/8" Vinyl Siding • DBVR171 Vertical, DBHR171 Horizontal IN BOX™ Siding Profile Adapter Plate for Existing Dutch Lap Siding IN BOX™ • Replacement Covers T O I N S T A L L S T DBVC , DBVW IN BOX™ Replacement Covers Clear/White • Vertical DBHC , DBHW IN BOX™ Replacement Covers Clear/White • Horizontal DV1 Dryer Vent mounting block kit For mounting dryer vents on siding Y • DBVM1C , DBVM1W Clear/White • Vertical IN BOX™ Weatherproof-in-use, recessed electrical box for NEW Rigid Siding, Stucco and Textured Surfaces DBVR141 Vertical, DBHR141 Horizontal IN BOX™ Siding Profile Adapter Plate for Existing 1/2" Vinyl Siding • Y • DBVR171C , DBVR171W IN BOX™ Weatherproof-in-use, recessed electrical box for Existing Vinyl Siding Clear/White • Vertical • Dryer Vent mounting block kit N • DBVR151C , DBVR151W Clear/White • Vertical IN BOX™ Weatherproof-in-use, recessed electrical box for Existing Vinyl Siding • Back Cover I • DBVR141C , DBVR141W Clear/White • Vertical IN BOX™ Weatherproof-in-use, recessed electrical box for Existing Vinyl Siding • FS8171 Plastic, stepped weatherproof electrical box Deep design for GFCIs – For use on dutch lap siding A Dutch Lap DBHR141C , DBHR141W Clear/White • Horizontal IN BOX™ Weatherproof-in-use, recessed electrical box for Existing Vinyl Siding FS8161 Plastic, stepped weatherproof electrical box Deep design for GFCIs – For use on flat surfaces or siding P 5/8" • • • • L I S H • U L • • • • • • • Back Cover • 1/2" MM10 Plastic mounting block, 7" x 10" Mount disconnects, timers, cable TV boxes, and more on siding Patents Pending. S 1/4", 5/16" • FS8151 Plastic, stepped weatherproof electrical box Deep design for GFCIs – For use on 5/8" siding page Flat DBHR131C , DBHR131W Clear/White • Horizontal IN BOX™ Weatherproof-in-use, recessed electrical box for Existing Vinyl Siding FS8141 Plastic, stepped weatherproof electrical box Deep design for GFCIs – For use on 1/2" siding R with grounding lug • FS8091F Plastic, weatherproof electrical box For single-gang devices, including GFCIs NM cable connector • • • • • FS8171T Outlet box with threaded opening at top and bottom For use on dutch lap siding Stucco D DBHR1C , DBHR1W Clear/White • Horizontal IN BOX™ Weatherproof-in-use, recessed electrical box for Flat Surfaces and Siding DBHS1C, DBHS1W Clear/White • Horizontal IN BOX™ Weatherproof-in-use, recessed electrical box for NEW Vinyl Siding • FS8161T Outlet box with threaded opening at top and bottom For use on flat siding or surface IN BOX™ • • • • • FS8151T Outlet box with threaded opening at top and bottom For use on 5/8" siding 18-19 21-25 DBVR1C, DBVR1W Clear/White • Vertical IN BOX™ Weatherproof-in-use, recessed electrical box for Existing Flat Surfaces and Siding DBVS1C , DBVS1W Clear/White • Vertical IN BOX™ Weatherproof-in-use, recessed electrical box for NEW Vinyl Siding FS8141T Outlet box with threaded opening at top and bottom For use on 1/2" siding pages pages • 8171TR Kit with built-in electrical box, round with (2) threaded openings For mounting fixtures on dutch lap siding Box with weatherproof-in-use cover, installed bug plugs, (1) standard duplex and (1) One-piece assembly replaces the installation of an electrical box and bubble cover assembly Weatherproof-in-use, Low Profile Recessed Electrical Box • 8161TR Kit with built-in electrical box, round with (2) threaded openings For mounting fixtures on flat siding or surfaces IN BOX for NEW rigid siding includes... rated plastic for long outdoor life. IN BOX™ 8151TR Kit with built-in electrical box, round with (2) threaded openings For mounting fixtures on 5/8" lap siding 14-15 DBVM1C • 8141TR Kit with built-in electrical box, round with (2) threaded openings For mounting fixtures on 1/2" lap siding pages DBHM1W uses standard indoor wall plates or ■ 8131TR Kit with built-in electrical box, round with (2) threaded openings For mounting fixtures on 1/4" or 5/16" siding One-piece, recessed for new cementitious or fiber rigid ■ Flat IN BOX™ Weatherproof-in-use, Recessed Electrical Box for NEW Rigid Siding Dutch Lap Page 1 5/8" 1:55 PM 1/2" 6/10/08 1/4", 5/16" 123491_Lngfrd6pgr L I S T E D 123491_Lngfrd.2 6/6/08 7:05 AM Page 7 Installation of 8081F, 8081FDBL, 8082F, and 8091F with Flange Insert provided NM cable connector through the knockout of your choice and push the wire through. For inst alla tion sidi ng i s in stal led An electrical box and cover, all-in-one! BEFO RE Before siding is installed, using the ’flanged’ style, screw the box to the wall using the holes provided in the flange. Install siding around box section and caulk as required. Attach the cover (8081F shown). Connect the wires and install the fixture. For inst alla tion sidi ng i s in stal led 1 2 Place box section in desired location and pencil outline onto siding. 3 Cut along pencil line with razor knife and remove vinyl siding. 4 or Siding Type Unit Pkg Standard Pkg 8081 80812 All Types 25 8081DBL 80813 All Types 25 8081F 80814 All Types 25 Dim Style 25 6.5" x 6.5" w/o Flange 25 10.5" x 6.5" w/o Flange 25 6.5" x 6.5" with Flange 8081FDBL 80815 All Types 25 25 10.5" x 6.5" with Flange 8082F 32240 1/2" or Less 25 25 6.5" x 6.5" with Flange 8091F 17856 All Types 25 25 6.5" x 6.5" with Flange 8081FB 10941 All Types 25 25 — Box Only 8081FC 10939 All Types 25 25 — Cover Only 8091FB 10945 All Types 10 10 — Box Only 8091FC 10946 All Types 10 10 — Cover Only 8081FDBLC 10943 All Types 10 10 — Cover Only 8091FDBLC 10947 All Types 10 10 — Cover Only I N T A B L Install a duplex receptacle! Connect wires and install fixture. UPC/DCI/NAED MFG #01 8997 A Mount box section to substrate. Caulk as required. 5 Place siding block over box section (8081 shown). P The rectangular hole provides access to the wire connections. Siding block cover is placed over the electrical box. AFTE R Installation of 8081 and 8081DBL without Flange Catalog Number 8081F E • E A S Y T O I N S T A L L 7 123491_Lngfrd.2 6/6/08 7:05 AM Page 8 One-Piece Fixture Box tion talla FTER s n i A For Arlington’s one-piece E soirnstalled R O i F g E n fixture box is the easiest B sidi Patented 8141F Installation Before siding is up... No Extra Cover to Lose or Store! way to install light fixtures and receptacles on siding. 1 Remove knockout from 8141F. Insert cable connector. Push NM cable through connector. Its one-piece construction offers 2 Attach mounting block to easy installation, and there’s no substrate with (2) screws. 3 Install fixture according to cover to lose or store. manufacturer’s instructions. 8141F provides smooth vertical 4 Caulk as required. mounting of light fixtures on all siding types — before or after the After siding is up... siding goes up. 1 Cut hole in siding. 2 Break flanges off the back of the 8141F. Remove knockout. Insert cable connector in KO, then push NM cable through connector. 3 Attach mounting block to 8141F Costs 20% Less than 8081F! substrate with (2) screws. 4 Install fixture according to manufacturer’s instructions. 5 Caulk as required. ■ For light fixtures ■ One-Piece design ■ For use with All Siding Types ■ UL/CSA Listed ■ With flange, use for mounting before the siding is installed...with flange removed, can be used after the siding installation! ■ Made of high impact, UV-rated plastic for long outdoor life ■ Textured, paintable finish ■ NM cable connector included 8141F 8141F Fixture Box VS One-piece construction 2-pieces...electrical cover & box For lighting fixtures R with grounding lug UPC/DCI/NAED MFG #01 8997 8141F 10761 S T Y L I S H • For lighting fixtures & standard receptacles Description Unit Pkg Standard Pkg One-Piece 10 10 Fixture Box 4-1/8" diameter x 1/2" deep For All Siding Types Arlington 8 Catalog Number 8081F Electrical Box U L L I S T E D 123491_Lngfrd.2 6/6/08 7:05 AM Page 9 Siding Box Kit with MEGA Mounting Plate! 8091FDBL Installation Mount coach lamps that are too big for BEF For instal latio O n sidinRE o g is r A inst FTE alled R smaller mounting plates with Oversized 7-1/8" x 13-1/2" Mounting Plate gives rigid support to large coach lamps. 8091FDBL. It has the largest mounting plate available and an Extra Deep 24.5 cubic inch UL Listed box - for fixtures with transformers under the base. extra deep electrical box. 1 Insert provided NM cable connector through the knockout of your choice and push the wires through. The box and cover are made of 2 Box section mounts to substrate. Caulk as required. painted to accommodate any 3 Place MEGA block plate over box section. color scheme. UV-rated plastic and can be 4 Install fixture. Mount the Largest Coach Lamps with 8091FDBL! ■ Sturdy mounting surface provides a solid mount for large fixtures. ■ Provides a UL Listed installation. ■ For use with All Siding Types. ■ With flange, use for mounting before the siding is installed...with flange removed, can be used after the siding installation! ■ Kit includes a NM cable connector. ■ Cover may be rotated 180° to accommodate fixtures with mounting holes above or below center line. 8091FDBL Notched on back for removal of outside flange for retrofit work. Use ‘Down’ or ‘Up’ to fit any mounting hole configuration. R Catalog Number UPC/DCI/NAED MFG #01 8997 Description 24168 MEGA Mounting 8091FDBL A Standard Pkg 10 10 with grounding lug Plate Assembly 7-1/8" x 13-1/2" For All Siding Types P Unit Pkg I N T A B L E • E A S Y T O I N S T A L L 9 123491_Lngfrd.2 6/6/08 7:05 AM Page 10 Siding Mounting Kits with Built-in Box Patented For Installing Light Fixtures Vertical on Sided Structures. Arlington offers a complete Siding Mounting Kit for Determine your Siding Type, to Select the Proper KIt...1/4" & 5/16", 1/2", 5/8", or Dutch Lap Siding! smooth, vertical mounting of lighting fixtures on all siding types! tion talla s n i For ER d AFiTs installe g sidin Made of UV-rated plastic for long, outdoor life, the textured surface is paintable to match the mounting surface. The built-in electrical box design ensures a UL Listed installation every time. Each kit includes: Mounting Block with Built-in Electrical Box, NM Cable Connector and 4 Screws. R with grounding lug Arlington 10 S T Y L I S H • U L L I S T E D 123491_Lngfrd.2 6/6/08 7:05 AM Page 11 8131, 8141, 8151, and 8171 Siding Installation 8141 1 Select location for light fixture and caulk opening around cable. 2 Remove knockout from electrical box and insert cable connector. Push cable through connector and position mounting block onto siding. B C A Dutch Lap Lap Siding 3 Secure mounting block with provided screws. Install fixture. 8141DBL Easily converts to an Oversized fixture see MEGA Siding Plate on page 13! Catalog Number UPC/DCI/NAED MFG #01 8997 Siding Type Std Pkg Dim A* Dim B* Dim C* 8131 08131 1/4" & 5/16" Lap 10 4" Diameter x 1/2" Deep 6.625" 6.625" 8141 10751 1/2" Lap 10 4" Diameter x 1/2" Deep 6.625" 6.625" 8141DBL 54524 1/2" Double 10 4" Diameter x 1/2" Deep 6.625" 10.200" 8151 10753 5/8" Lap 10 4" Diameter x 1/2" Deep 6.625" 6.625" 8161 08161 Flat Surfaces 10 4" Diameter x 1/2" Deep 6.625" 6.625" 8171 10757 Dutch Lap 10 4" Diameter x 1/2" Deep 6.625" 6.625" B C A 1/2" Double Lap Siding 8141DBL *For Dimensions A, B, and C, see drawings above P A I N T A B L E • E A S Y T O I N S T A L L 11 123491_Lngfrd.2 6/6/08 7:05 AM Page 12 Siding Mounting Kit with Built-in Box for installing light fixtures on FLAT Surfaces! 8161 Flat Surface Installation 1 Select location for light fixture and caulk opening around cable. Remove KO, insert cable connector, push cable through and position block on surface. 2 Secure mounting block with provided screws and apply paint to textured block to match wall surface. 8161...Installs Light Fixtures Vertically on Any FLAT Surface! 8161 3 B Flat Secure mounting block with provided screws. Install fixture. 8161 C A Catalog Number R with grounding lug UPC/DCI/NAED MFG #01 8997 Siding Type Std Pkg Dim A* Dim B* Dim C* 08161 Flat Surfaces 10 4" Diameter x 1/2" Deep 6.625" 6.625" 8161 Arlington 12 S T Y L I S H • U L L I S T E D 123491_Lngfrd.2 6/10/08 3:01 PM Page 13 MEGA Siding Plates...the Largest Mounting Covers in the Industry! For use with Arlington’s Siding Blocks and Boxes... 8131 ■ 8141 ■ 8161 ■ 8171 * for 8100MLP only 8151 ■ 8082F ■ For inst allat sidinAFTE ion g is R inst alled Support large fixtures or coach lamps the easy way by ■ ■ converting the standard size cover 8091F* to a MEGA or SUPER MEGA cover. And most other manufacturers’ mounting blocks. There’s no need to remove the octagonal block you’ve already installed. The MEGA mounting plate MEGA Siding Plate installation fits right over the existing block. 1 Remove existing light fixture and mounting bracket. 8100LP 2 Determine the mounting location for new fixture on mounting plate. May be rotated 180° to accommodate fixtures with offcenter mounting. 3 Place the 8100LP MEGA Siding Plate over the fixture mounting screws. 4 Install the new, large light fixture. 8100MLP May be rotated 180° to accommodate fixtures with offcenter mounting. SUPER MEGA Siding Plate installation 1 Use with an existing mounting block. 2 Disconnect electrical power. Align slots and secure the 8100MLP to the siding block. 3 Install extra large fixture per manufacturer’s instructions. 4 If screw holes are offset, simply rotate the 8100MLP 180°. Catalog Number UPC/DCI/NAED MFG #01 8997 Description Unit Pkg Standard Pkg 8100LP 10749 MEGA Siding Plate 7-1/8" x 13-1/2" 1 10 8100MLP 10752 SUPER MEGA Siding Plate 8-1/2" x 16" 1 10 P A I N T A B L E • E A S ■ Accommodates light fixtures with mounting brackets up to 12" ■ Provides a smooth, secure mounting surface for large fixtures ■ Instantly converts a previously installed octagonal siding block to a MEGA siding plate ■ Adjusts up to 1" for offset mountings ■ Features alignment mounting slots to guarantee the MEGA Siding Plate will stay securely in position ■ Made of UV-rated, paintable plastic Patented / Other patents pending. Y T O I N S T A L L 13 123491_Lngfrd.2 NEW 6/6/08 7:06 AM Page 14 Fixture Boxes with Threaded Openings 8161TR for Flat Surfaces Install a fixture now, anywhere you want it – add another fixture later. It’s easy with Arlington’s non-metallic fixture boxes with threaded openings. Saves Time. Convenient! This box installs in either the horizontal or vertical orientation, and gives you the option of installing your fixture where you need it. You can also install Add another Fixture or Outlet, the EASY way! additional security or flood lights at a later time through the threaded openings. 8161TR Installation Convenient and versatile, 8161TR is designed for flat surfaces. We also have an adapter plate for each siding type that allows this box to be used on all siding types (see pages 18-19 for outlet boxes Patent pending with threaded openings). ■ Non-metallic ■ Includes two threaded openings ■ Installs fixtures on flat, exterior surfaces ■ UV-rated ■ Textured, paintable finish 1 Pull wire. Attach box to flat surface. 2 Install fixture. 3 Use threaded opening(s) and PVC conduit... 4 to install additional fixture(s). 8161TR fixture box for flat surfaces Catalog Number UPC/DCI/NAED MFG #01 8997 Siding Type Unit Pkg Standard Pkg 8161TR 00878 Flat Surfaces 10 10 Includes NM cable connector, (4) screws, (2) 1/2" NPT plugs Arlington 14 S T Y L I S H • U L L I S T E D 123491_Lngfrd.2 6/6/08 7:06 AM Page 15 8131TR, 8141TR, 8151TR, 8171TR for Siding We designed an adapter plate that converts the 8161TR box for flat surfaces into a fixture box that can be used on any siding type. ■ Non-metallic ■ Includes two threaded openings ■ Install fixtures on any siding type ■ UV-rated ■ Textured, paintable finish Patent pending An adapter plate converts the flat style for use on any siding type 8171TR for Dutch Lap 8161TR 8171TR Installation 1 Pull wire. Attach box to siding surface. Install fixture. 2 Use threaded opening(s) and PVC conduit...to install additional fixture(s). Catalog Number UPC/DCI/NAED MFG #01 8997 Siding Type Unit Pkg Standard Pkg 8131TR 8141TR 8151TR 8171TR 00875 00876 00877 00879 Rigid 1/4" or 5/16" 1/2" 5/8" Dutch Lap 10 10 10 10 10 10 10 10 Includes NM cable connector, (4) screws, (2) 1/2" NPT plugs P A I N T A B L E • E A S Y T O I N S T A L L 15 123491_Lngfrd.2 6/10/08 2:10 PM Page 16 Mounting Bases for Meters and other Products tion talla s n i For Arlington’s one-piece, ORE led BEgFis instal n non-metallic Mounting i sid MM18, MM23 meter mounting bases Bases provide a secure, flat Support even the largest electric meters mounting surface for even the largest electric meters. MM23 Redesigned for even easier use, the squared-off corners allow the MM18 bases to be butted together for gang installations! They install before or after the siding goes up, work with any siding type, and accommodate almost all meter sizes! They’re UV-rated for long outdoor life and paintable to match any color scheme. ■ Provides a flat mounting surface ■ UV-rated for long outdoor use ■ Textured, paintable surface ■ One-piece, non-metallic ■ Provides a 1" overhang to cover cut ends of siding ■ Gangable to accommodate most meters and other products MM10 mounting block Mounts a variety of products on siding — fast! ■ Disconnects ■ Keypads ■ Timers ■ Telephone Boxes ■ Cable TV Boxes Our 7” x 10” one-piece Mounting Blocks mount a variety of products simply and securely on siding. The block’s overhang hides cut ends of siding for a clean, attractive installation. See chart on next page to select the product matching your specific installation condition. MM10 Arlington 16 S T Y L I S H • U L L I S T E D 123491_Lngfrd.2 6/6/08 7:06 AM Page 17 MM10, MM18, and MM23 Installation 1 1 Fasten to substrate through ‘notched flanges’. 2 Siding butts to Meter Base, overlapping the ‘notched flanges’. 3 Meter Base mounting surface provides a 1" overhang to hide cut ends of siding. 4 And you’re ready to mount the meter. 5 Caulk as required. 4 2 3 Gangable Meter Base combinations Mounting options MM10 14" MM18 MM10 MM18 31-3/4" 10" 35-1/4" MM23 MM18 MM18 MM10 MM18 20" MM10 17-5/8" 15-7/8" 7" Seal all vertical joint channels with Arlington’s DSC1 Duct Sealing Compound MM23 MM23 MM23 46" 35-1/4" 38-7/8" MM23 MM18 MM23 17-5/8" 23" 17-5/8" MM18 MM18 Rotate all illustrated combinations 90° for additional surface mounting options. Catalog Number UPC/DCI/NAED MFG #01 8997 Description Unit Pkg Standard Pkg MM10 42278 Meter Mounting Block 7" x 10" 10 10 MM18 42280 Meter Mounting Base 10 10 10 10 17-5/8" x 15-7/8" 42282 MM23 Meter Mounting Base For All Siding Types P 23" x 17-5/8" A I N T A B L E • E A S Y T O I N S T A L L 17 123491_Lngfrd.2 NEW 6/6/08 7:06 AM Page 18 Outlet Box with Threaded Openings FS8161T for Flat Surface Shown with Arlington’s 60VW IN and OUT™ Cover (sold separately) Install a receptacle where you need it; add another outlet box later. It’s easy with Arlington’s non-metallic threaded-opening outlet boxes. Saves Time. Convenient! The FS8161T box gives you the option of installing the receptacle where you need it – in horizontal or vertical orientation. The threaded openings allow for the installation of additional outlet boxes at a later time. Patent pending Convenient and versatile, FS8161T is designed for flat surfaces. We also have an adapter plate for each siding type that FS8161T outlet box for flat surfaces converts the FS8161T box for use on all siding types. ■ Non-metallic ■ Includes two threaded openings ■ Installs devices on flat, exterior surfaces ■ UV-rated ■ Textured, paintable finish Add another Outlet, the EASY way! FS8161T Installation 1 R with grounding lug Pull wire. Attach box to flat surface. 2 Install receptacle. 3 Catalog Number UPC/DCI/NAED MFG #01 8997 Siding Type Unit Pkg Standard Pkg FS8161T 00873 Flat 10 10 Includes (2) 1/2" NPT plugs Arlington 18 S T Y L Use threaded opening(s) and PVC conduit to install additional outlet boxes. I S H • U L L I S T E D 123491_Lngfrd.2 6/6/08 7:06 AM Page 19 FS8131T, FS8141T, FS8151T, FS8171T Outlet Boxes with Threaded Openings for Siding We offer an adapter plate that converts the FS8161T box for flat surfaces into an outlet box that can be used on any siding type. ■ Non-metallic ■ Includes two threaded openings ■ Install devices on any siding type ■ Horizontal or vertical installation ■ UV-rated ■ Textured, paintable finish Patent pending FS8171T outlet box with adaptor for dutch lap siding FS8171T Installation The adapter plate converts the flat box for use on any siding type 1 Pull wire. Attach the appropriate adapter to the FS8161T box and install on siding. 2 Install receptacle. 3 FS8161T Use the threaded openings to add another Outlet Box. Use the threaded openings to add another Outlet Box! Catalog Number UPC/DCI/NAED MFG #01 8997 Siding Type Unit Pkg Standard Pkg FS8131T FS8141T FS8151T FS8171T 00870 00871 00872 00874 Rigid 1/4" or 5/16" 1/2" 5/8" Dutch Lap 10 10 10 10 10 10 10 10 FS8171T for Dutch Lap Includes (2) 1/2" NPT plugs P A I N T A B L E • E A S Y T O I N S T A L L 19 123491_Lngfrd.2 6/6/08 7:06 AM Page 20 Weatherproof Outlet Box and FS Boxes tion talla FTER s n i A For For fast and easy E soirnstalled R O i F g E n vertical or horizontal installi B sid Outlet Box for single-gang devices, including GFCIs! ation of devices in dry locations, FS8091F is your best buy for areas that don’t require a weatherproof Add a weatherproof- in-use cover to meet code in wet locations. To save money on the total cost of the box and cover – and get a great looking job too, check out our one-piece IN BOX™ for siding on page 22. while in use cover. Although FS8091F can be used with a bubble cover for wet locations as required by the NEC, our IN BOX™ (DBVS1C or W) FS8091F on page 22 costs less than the FS8091F Installation combined cost of the outlet box and a bubble cover – and looks a whole lot better! R Before siding is up... after siding is up... 1 Remove knockout and insert cable connector. Push NM cable through connector. 1 Cut hole in siding. ■ For all siding types ■ Installs before or after siding ■ Works with all single-gang, devices including GFCIs 4 Install single-gang device (regular or GFCI). 4 Caulk as required. 5 Caulk as required. Catalog Number UPC/DCI/NAED MFG #01 8997 17303 FS8091F n atio stall n i r Fo ER d AFiTs installe g sidin 3 Attach outlet box to substrate with (2) screws. 3 Install device, FS8091F works with all single-gang devices. For All Siding Types Description Unit Pkg Standard Pkg Outlet Box for 10 10 installing devices on siding Weatherproof FS Boxes ■ Non-metallic ■ For use with All Siding Types...1/2", 5/8", Dutch Lap, and Flat Surfaces. mounting GFCIs, switches, and ■ For GFCI, switches, and outlets. outlets on all ■ UV-rated for outdoor applications. ■ Provides a UL Listed installation. ■ Textured, paintable finish. Arlington’s one-piece FS Box ensures a solid, UL Listed installation every time. Perfect for siding types or flat surfaces, the FS Box is easy to convenient to use. FS8171 for Dutch Lap Siding R with grounding lug Arlington S T Now There’s a Plastic, Weatherproof FS Box for Siding! Install your choice of either a GFCI, Switch or Duplex receptacle. The FS Box’s unique design accepts them all! install and 20 2 Break flanges off the back of the FS8091F. Remove knockout. Insert cable connector in KO, then push NM cable through connector. 2 Attach outlet box to substrate with (2) screws. FS8091F with grounding lug Y L Catalog Number UPC/DCI/NAED MFG #01 8997 Description Unit Pkg Standard Pkg FS8141 17340 1/2" Lap Siding 25 25 FS8151 17341 5/8" Lap Siding 25 25 FS8161 17342 Flat Surfaces 25 25 FS8171 17343 Dutch Lap Siding 25 25 I S H • U L L I S T E D 123491_Lngfrd.2 6/6/08 7:06 AM Page 21 IN BOX™ Weatherproof-in-use, Recessed Electrical Box for Flat Surfaces and Siding ting S One-piece, exis ACE recessed electrical For F R T SUsiding box with weatherproofFLA and in-use cover for flat surfaces in existing construction. Non-metallic cover and base. Accepts most single-gang wiring devices and DBHR1W uses standard indoor wall plates DBVR1C or a GFCI cover plate. Box and white cover are textured/ IN BOX for retrofit, flat surfaces and siding includes... paintable. UV-rated plastic for long Box with weatherproof-in-use cover, installed bug plugs, (1) standard duplex and outdoor life. (1) standard GFCI face plate, (1) set installation screws, (1) NM cable connector, and (1) roll of caulk. ■ IN BOX’s one-piece assembly replaces the installation of an electrical box and bubble cover assembly ■ Installs in the wall, so less of it shows outside ■ Use the retrofit IN BOX on flat siding, T-111, and other flat surfaces ■ Install option: Cover is removable for easier device installation ■ No gaskets required Installation Instructions 1 Cut a 3-1/4" x 5-1/2" hole in substrate. Pull wiring. 2 Apply the supplied caulk around back edges of flange. Install NM cable connector and wire, then press onto surface. Attach IN BOX with stainless steel screws provided. 3 Bug Plugs ship installed in all IN BOX styles to seal unused cord hole openings. 22 cu. in. A 4 Install wiring device per manufacturer’s instructions, local and National Electrical Codes. CATALOG NUMBER DBVR1C DBVR1W DBHR1C DBHR1W Accepts most single gang wiring devices, and uses a standard indoor wall plate. DBVR1C shown. B DBVR1W shown. IN BOX Saves Time. Looks Great! D C UPC/DCI/NAED MFG #01 8997 Orientation/ Cover color UNIT PKG STD PKG DIM A DIM B DIM C DIM D DIM E 14313 14314 77604 77606 Vertical/Clear Vertical/White Horizontal/Clear Horizontal/White 1 1 1 1 4 4 4 4 7.186 7.186 4.934 4.934 4.934 4.934 7.186 7.186 5.160 5.160 5.160 5.160 1.313 1.313 1.313 1.313 3.847 3.847 3.847 3.847 E Note: Meets 2008 NEC Section 406-8; for the protection of exterior outlets which require the use of a weatherproof while-in-use cover for all outdoor 15 or 20 AMP receptacles. R Replacement covers and siding profiles to convert for use on existing siding available on page 25. Patents Pending. P A I N T A B L E • E A S Y T with grounding lug O I N S T A L L 21 123491_Lngfrd.2 6/6/08 7:06 AM Page 22 IN BOX™ Weatherproof-in-use, Recessed Electrical Box for NEW Vinyl Siding For YL VIN W g NE sidin Our one-piece IN BOX for new siding eliminates the need to install an electrical box and a siding block, and a bubble cover assembly. ■ Outer flange covers cut ends of siding ■ Fits all siding types ■ Install before new siding goes up ■ Clear or white, vertical or horizontal styles DBHS1W DBVS1C Installation of IN BOXES or NEW Vinyl Siding 1 Cut hole. Pull wiring. Install NM cable connector and wire. Attach IN BOX to substrate. 2 Siding profile Install siding, inserting the cut ends of the siding under the outer flange of the IN BOX. 3 IN BOX accepts most single gang wiring devices, and uses a standard indoor wall plate. Catalog Number adapter plate allows use of the retrofit IN BOX on any siding type. UPC/DCI/NAED MFG #01 8997 Orientation/ Cover Color Unit/Std Pkg DBVS1C DBVS1W 14317 14318 Vertical/Clear Vertical/White 4 4 DBHS1C DBHS1W 77600 77602 Horizontal/Clear Horizontal/White 4 4 R with grounding lug Arlington 22 S T Y L I S H • U L Install wiring device L I S T E D 123491_Lngfrd6pgr 6/10/08 4:26 PM Page 2 IN BOX™ Weatherproof-in-use, Recessed Electrical Box for EXISTING Vinyl Siding Siding Box Kits Arlington siding box kits give you Siding from Arlington! Solutions DBVR141W Listed and approved installation— Box Depth: 1.125 (15.5 cu. in.) because this siding box is an actual electrical junction box! Each kit includes an electrical box, 8081F, 8081 cover, and NM cable connector Arlington’s siding mounting boxes and kits give you what you need and works on all siding types, to install any kind of receptacle or light fixture on any kind of siding— before or after the siding L We fitted our INY V retrofit IN BOX G STINsiding with a siding profile I X E For .895 everything you need for a UL 8081 (flangeless) adapter plate for use on existing siding! Note: 8081 is flangeless For Standard Light Fixtures and Devices 8081F (with flanges) is installed. Before the siding is before or after the siding goes up! A installed, use the ‘flanged’ 8081F, .895 8081FDBL, 8082F, or 8091F. If the Outdoor receptacles, boxes, meters, light fixtures, even extra large Box Depth: 1.125 (15.5 cu. in.) siding is up or for retrofit work, coach lamps, can now be mounted firmly and securely with break the flanges off the flanged Arlington’s ‘Siding Solutions’! Whatever your siding type or installation styles above along the prescored condition, we have what you need. From flanged to unflanged, lines or use our ‘flangeless’ styles standard electrical boxes or deeper ones for GFCIs, regular or extra 8081 or 8081DBL. For fixtures and D Installation of IN BOXES for EXISTING Vinyl Siding C A Note: 8081DBL is flangeless A B E B 8081FDBL, 8081DBL receptacles that require GFCIs, large mounting plates and individual boxes and covers, even flat B 22 cu. in. 8081DBL (flangeless) For Large Light Fixtures 8081FDBL (with flanges) use the deeper 8091F. surface designs, Arlington siding mounting products provide the Easy to install, this series of answer. .375 siding mounting boxes features premolded screw locations for Installation is fast and easy. And with Arlington’s mounting boxes Box Depth: 1.125 (15.5 cu. in.) devices and lighting fixtures. The and kits you get smooth vertical mounting of all fixtures and box enclosure can be installed in receptacles. Plus, mounting boxes made of UV-rated plastic provide two ways. The first method uses long outdoor life. The textured surface is paintable to blend in with the location holes for a typical the color of your siding. 3-1/2" or 4" diameter box. The 8082F 1 Using the siding profile adapter plate as a template, cut hole in existing siding. Pull wiring. 2 second uses the screw locations for device mounting when For Canadian shipments the grounding lug rotated 90°. is included as required by CSA. Box Depth: 1.625 (24.5 cu. in.) rectangular hole for accessing the shown with grounding lug. the Arlington solution that’s right for you! wire connections in the box enclosure. 8091F For GFCIs, Large Devices and Fixtures, Fixtures with Ballast 8091F (with flanges) Notched for removal of outside flange for retrofit work 6.625 4.500 R R with grounding lug Arlington 3A. Apply caulk to reverse side of IN BOX flange. 3B. Install NM cable connector and wire, then attach with long screws (provided). Trim excess caulk as needed. Install wiring device. .925 These mounting boxes provide a Refer to the Product Selector Guide to find 3 2B. Attach adapter to siding with short screws (supplied) through the holes noted above. Trim excess caulk as needed. For Fixtures and Devices on T-111 Siding 8082F (with flanges) 2A. Apply caulk around edges of back of adapter. Press onto siding. Front View (Flanged) Front View (Without Flange) Back View (Flanged) Catalog Number UPC/DCI/NAED MFG #01 8997 Orientation Cover Color Siding Lap Size Unit/Std Pkg 77612 77614 77616 77618 77620 77622 77624 77626 14370 14375 14371 14376 14372 14377 14373 14378 Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Clear White Clear White Clear White Clear White Clear White Clear White Clear White Clear White 1/4, 5/16 1/4, 5/16 1/2 1/2 5/8 5/8 Dutch Lap Dutch Lap 1/4, 5/16 1/4, 5/16 1/2 1/2 5/8 5/8 Dutch Lap Dutch Lap 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 DBHR131C DBHR131W DBHR141C DBHR141W DBHR151C DBHR151W DBHR171C DBHR171W DBVR131C DBVR131W DBVR141C DBVR141W DBVR151C DBVR151W DBVR171C DBVR171W Arlington 5 6 S T Y L I S H • U L L I S T E D P A I N T A B L E • E A S Y T O I N S T A L L 23 123491_Lngfrd.2 6/6/08 10:15 AM Page 25 Installation Instructions for New Rigid Siding - Method 1 1 Install NM cable connector and wire. Attach IN BOX to stud. 2 Install moisture barrier around IN BOX per manufacturer’s instructions. Cut rigid siding to fit around IN BOX. Caulk around box. 3 4 Install wiring device per manufacturer’s instructions, local, and National Electrical Codes. Accepts most devices and a standard indoor wall plate. DBVM1W shown. 4 Install wiring device per manufacturer’s instructions, local, and National Electrical Codes. Accepts most devices and a standard indoor wall plate. DBVM1W shown. Installation Instructions for New Rigid Siding - Method 2 1 Make a 3-1/4" x 5-1/2" hole in plywood. Pull wiring through opening. 2 Install NM cable connector and wire. Attach recessed IN BOX to substrate, then install moisture barrier around box as shown above in Method 1. Cut rigid siding to fit around IN BOX. Caulk around box. 3 IN BOX™ Siding Profile Adapter Plates for Existing Siding Retrofit ting Exis For YL g VIsN i id n Adapter plates convert the flat surface retrofit DBVR1 and DBHR1 IN BOX series (see page 21) for use on existing siding. Order the siding profile adapter plate to fit your particular siding type. UV-rated plastic for long outdoor life. Paintable. DBVR141 Catalog Number UPC/DCI/NAED MFG #01 8997 Orientation Siding Type Std Pkg DBVR131 14368 Vertical 1/4" or 5/16" Lap 4 DBVR141 14379 Vertical 1/2" Lap 4 DBVR151 14381 Vertical 5/8" Lap 4 DBVR171 14383 Vertical Dutch Lap 4 DBHR131 77654 Horizontal 1/4" or 5/16" Lap 4 DBHR141 77656 Horizontal 1/2" Lap 4 DBHR151 77658 Horizontal 5/8" Lap 4 77660 Horizontal Dutch Lap 4 DBHR171 Adapter plate for IN BOX includes...Siding profile adapter plate, installation screws, and (1) roll of caulk. P A I N T A B L E • E A S Y T O I N S T A L L 25 123491_Lngfrd.3 6/10/08 4:33 PM Page 26 IN BOX™ Replacement Covers Replacement covers sold separately. Clear is not paintable and white is textured, paintable. DBHW A UV-rated DBVC plastic for long outdoor life. ion allat inst For R O E led BEgFis instal sidin Catalog Number B C UPC/DCI/NAED MFG #01 8997 Orientation Siding Type Std Pkg Dim A Dim B Dim C DBVC 77640 Vertical/Clear 1 4 5.650 3.420 .370 DBVW 77642 Vertical/White 1 4 5.650 3.420 .370 DBHC 77650 Horizontal/Clear 1 4 3.420 5.650 .370 DBHW 77652 Horizontal/White 1 4 3.420 5.650 .370 Dryer Vent Mounting Block Kit Arlington’s one-piece, non-metallic dryer vent mounting ■ Clean, attractive installation – overhang covers cut ends of siding ■ Smooth vertical mounting of dryer vents on any siding type ■ For new siding construction ■ Easy installation ■ Colors: Paintable White ■ Pre-mounted vent: 4" x 10-1/2" tube dimension block kit provides the secure, attractive – and time-saving way to install dryer vents on new siding. Our 8 x 8 inch dryer vent mounting block kit comes complete with a low profile, louver-type hood, a snap-together 4" aluminum tube and a siding block with a built-in j-channel. It fits all siding types: 1/2" and 5/8" step, and dutch lap. UV-rated, and weather-resistant for long outdoor life, they’re also paintable to match any color scheme. DV1 Installation of Dryer Vent Mounting Block Kit 1 Cut hole in substrate with a 4-1/2" hole saw. Insert vent tube into opening. Catalog Number All products are Patented and/or other Patents Pending. DV1 2 Use screws to mount dryer vent to substrate through flanges. 3 UPC/DCI/NAED MFG #01 8997 Description Siding Type Unit Pkg Standard Pkg 43607 Dryer Vent Mounting Block 8" x 8" vented plastic block Mounts before siding All 1 10 Arlington 1 Stauffer Industrial Park Scranton, PA 18517 800/233.4717 Fax 570/562.0646 www.aifittings.com ©1999-2007 Arlington Industries, Inc. 26 0608/50M S T Y L I S H Install siding. Overhang on vent flange hides cut ends of siding. Caulk as required. DV1 Dryer Vent Mounting Block installed. • U L L I S T E D