BASKET
EXAM LOUVRE
LOUVRE LATCHES
LED NIGHT LIGHT PLATE
MOUNTING SCREWS (2x)
READING LAMP
VALENCE
LED NIGHT LIGHT
LED NIGHT LIGHT
REMOVEABLE PLATE
BALLAST COMPARTMENT COVERCOVER
REMOVE LVC COVER TO ACCESS
LOWER VOLTAGE SWITCH LINES
FOR AMBIENT AND READING
SECTIONS. WIRE ACCESS HOLE
PROVIDED UNDER LVC COVER.
COVER MOUNTING SCREWS (4x)
LOW VOLTAGE
CONTROLLER (LVC)
ADDITIONAL LAMP UNDER VALENCE.
CAN BE ADDED BY REMOVE THE
VALENCE/LENS
BALLASTS
VALENCE/LENS THUMB SCREWS
POWER ENTRY FOR 120V LINE VOLTAGE.
(POWER FOR FOR ALL 3 MODULES).
LOUVRE AND COVER REMOVED
INSTALL IN COMPLIANCE TO ALL APPLICABLE ELECTRICAL AND BUILDING CODES.
INSTALLATION MUST BE PERFORMED BY QUALIFIED PERSONNEL.
CAUTION: SHOCK HAZARD. DISCONNECT ALL POWER BEFORE PEFORMING INSTALLATION
INSTRUCTIONS:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
REMOVE THE LOUVRE.
1.
TWO (2) LATCHES CAN BE LIFTED AT ONE END. CAREFULLY LET THE LOUVRE ROTATE DOWNWARD. SPIN LOUVRE IN HORIZONTAL PLAVE
TO DISLODGE HINGE AT ONE SIDE FROM ITS TRACK.
2.
THE LOUVRE IS NOW FREE TO BE REMOVED.
REMOVE THE 2 SCREWS HOLDING THE LED PLATE. FEED THE PLATE THROUGH THE RECTANGULAR HOLE.
REMOVE 4 SCREWS HOLDING THE BALLAST COMPARTMENT COVER AND CAREFULLY REMOVE THE COVER. THE LED PLATE WILL REMAIN WITH
THE FIXTURE AND HANG BY THE WIRE. TEMPORARILY TAPE THIS PLATE TO THE INTERIOR OF THE HOUSING.
MOUNT THE FIXTURE IN CEILING GRID. SECURE THE FIXTURE IN PLACE AS PER LOCAL BUILDING CODES. EQ CLIPS WITH MOUNT HOLES ARE
PROVIDED ON THE FIXTURE.
ELECTRICALLY HOOK UP FIXTURE WITH 120V AND LOW VOLTAGE SWITCHING LINES. (MUST BE PERFORMED BY QUALIFIED ELECTRICIAN). THE
LVC-060 USER DATASHEET IS PROVIDED FOR YOUR REFERENCE.
HOOK APPROPRIATE GROUNDING TO POWER ACCESS PLATE. THIS PLATE MUST ALSO BE GROUNDED TO THE HOUSING GROUND STUD (NEAR
ACCESS PLATE - DONE AT FACTORY.)
AFTER ALL WIRING IS COMPLETED, RE-ATTACHED THE BALLAST AREA COVER. CAREFULLY FEED THE LED PLATE THROUGH THE RECTANGULAR
HOLE AND RE-MOUNT THE PLATE TO THE BALLAST AREA COVER OVER THE RECTANGULAR CUT-OUT.
REMOVE THE BASKET BY CAREFULLY PRYING ONE SIDE AWAY FROM MOUNTING STUDS AND CAREFULLY MOVE IT AWAY. REMOVE READING
LAMP VALENCE/LENS BY LOOSENING THE THUMBSCREWS.
ADD LAMPS IN ALL COMPARTMENTS (1x READING / 1x AMBIENT / 4x EXAM).
RE-ASSEMBLE THE FIXTURE BY PERFORMING STEPS IN REVERSE ORDER.
RE-CONNECT MAIN POWER.
NAME
Drawn
DATE
R
Last Saved rdoucet
35 Oak St., Toronto, ON M9N 1A1
9/5/2013
Checked
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
CERTOLUX - DISVISION OF VISIONEERING
CORP. ANY REPRODUCTION IN PART OR
AS A WHOLE WITHOUT THE WRITTEN
PERMISSION OF CERTOLUX IS PROHIBITED.
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
ANGULAR: BEND 1
ONE PLACE DECIMAL 0.030
TWO PLACE DECIMAL 0.015
THREE PLACE DECIMAL 0.005
IIS00049
ERP #:
Title
Part Name:
Description:
A
647-777-3300
01
IIS.-.3452.G.CER.V39.V40
MD3G 3452 WITH LVC AND LED NIGHT-LIGHT INSTALLATION
MATERIAL:
SIZE:
REVISION:
FINISH:
SCALE:
None
SHEET 1 of 1