Cutler-Hammer Molded Case Circuit Breakers Motor Circuit Protectors January 2001 12-117 Vol. 1, Ref. No. [0583] Product Selection This information is presented only as an aid to understanding Catalog Numbers. It is not to be used to build Catalog Numbers for circuit breakers or trip units. Table 12-181. Motor Circuit Protector Catalog Numbering System H M C P 003 AO C 1_ I I Continuous Ampere Rating Motor Circuit Protective Type HMCP HMCPE HM2P HMCPS I Magnetic Trip Range/ NEMA Starter Size 003 007 015 025 030 050 = 3 Poles = 3 Poles = 2 Poles © = 3 Poles * AO = CO = EO = DO = HI = 62 = K2 = J2 = M2= L3 = R3 = T4 = U4 = AS = C5 = D5 = F5 = G5 = J5 = K5 = L5 = W5 = N5 = R5 = X5 = Y5 = L6 = X6 = Y6 = X7 = Y8 = 070 100 I 150 250 400 600 800 1200 Suffix 9 - 30/0 21 -70/0 45-150/0 40 - 60/0 SUU/I 90-"~" 80-120/2 150-500/2 115- 170/2 210-700/2 160-240/3 300-1000/3 450-1500/4 750 - 2500/4 350 - 700/5 450-900/5 500-1000/5 625-1250/5 750- 1500/5 875-1750/5 1000-2000/5 1125-2250/5 1250-2500/5 1500-3000/5 1750-3500/5 2000-4000/5 2250-4500/5 1800 -6000/6 (Electronic) 500 - 2500/6 (Electronic) 1000 -4000/6 (Electronic) 1600 -6400/7 (Electronic) 2400 - 9600/8 (Electronic) C = Non-aluminum Terminals W = W/0 Terminals X = Load Terminals Only Y = Line Terminals Only S = Stainless Steel Terminals (150A Frame Only) No Suffix: Standard Terminals on Line and Load . © On J- ancj K-Frame HMCPs only. Table 12-182. Motor Circuit Protector Catalog Numbering System G M C P 003 AO C I r Motor Circuit Protective Device GMCP = 3 Poles HMCPE = 3 Poles CAT.200.01.T.E Continuous Ampere Rating _l ————— Magnetic Trip Range/NEMA Starter Size GMCP 003 007 015 030 050 060 063 AO CO EO H1 K2 J2 M2 = 15-30/0 = 35-70/0 = 75-150/0 = 150-300/1 = 250 - 500/2 = 300 - 600/2 = 320 - 630/2 HMCPE 003 007 015 030 050 070 100 100 AO CO EO H1 K2 M2 R3 T3 = 9-33/0 = 21-77/0 = 45-165/0 = 90-330/1 = 150-550/2 = 210-770/2 = 300-1100/2 =500-1500/2 Suffix C = Non-aluminum Terminals For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog F.T-N Cutler-Hammer Molded Case Circuit Breakers Motor Circuit Protectors January 2001 Vol. I.Ref. No. 10582] Description I Motor Circuit Breakers Contents Page Motor Circuit Protectors Product Description. . . . . . . 1 2 - 1 1 6 Product Selection . . . . . . . . 1 2 - 1 1 7 Product Description Designated as the Cutler-Hammer Types GMCP, HMCPE and HMCP, the instantaneous-only Motor Circuit Protector (MCP) is available in ratings from 3A to 1200A for motor starter sizes 0 through 8. The MCP is designed to comply with the applicable requirements of Underwriters Laboratories Standard UL489, Canadian Standards Association Standard C22.2 No. 5.1, and International Electrotechnical Commission Recommendations IEC 157-1. The MCP is a recognized component (UL File E7819) and complies with the applicable requirements of Underwriters Laboratories Standard UL489. It is also designed to comply with the applicable requirements of Canadian Standards Association Standard C22.2 No. 5.1, International Electrotechnical Commission Recommendations IEC 157-1, and nameplates bear the CE marking. Note: Interrupting ratings are dependent on starter it is used with. See FRED 278. An innovative design of internal components allows higher MCP-starter combination interrupting ratings. The MCP is marked to permit proper electrical application within the assigned equipment ratings. E:T« For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E i Cutler-Hammer Molded Case Circuit Breakers Motor Circuit Protectors January 2001 12-121 Vol. 1, Ref. No. [0587] Special low Magnetic Protection Application MCP Table 12-190. 600V AC Maximum, 250V DC Maximum (Continued) Table 12-189. 600V AC Maximum, 250V DC Maximum Cont. Amps 25 MCP Trip Setting ® MCP Catalog Number A B C 40 43 46 49 HMCP025DOC D E F G H 50 70 0 15 80 87 93 98 103 A B C 115 C D E HMCP050G2C F G H 760. 1 30 G 160 H 170 A B C D E 160 174 185 196 207 218 229 240 F G H HMCP070J2C 915. 2 HMCP100L3C 50 915. ® For DC applications, actual trip levels are approximately 40% higher than values shown. Note: Instruction Leaflet/FRED Number 29C407 0 3 A B C D E F G H 0 7 A B C D E F G H MCP MCP Catalog Trip Setting Number ® .69 .921.1 1.3 - .91 1.0 1.2 1.5 9 12 15 1.6 1.8 2.0 2.3 1.7 1.9 2.2 2.5 21 24 27 30 - 2.6 3.2 3.7 4.3 4.8 5.3 - 4.7 56 5.2 63 5.7 70 2.5 I,; rr • CAT.200.01.T.E 600. 18 2.0 21 28 3.1 35 3.6 42 3.9 49 1.5 2.1 - HMCPS003AOC Price U.S.S HMCPS007COC 600. - 4.5 - 5.6 - 6.8 - 7.9 - 9.1 - 10.3 - 11.4 11.5 - 12.6 6.9 9.2 11.5 13.8 - 9.1 - 11.4 - 13.7 - 16.0 HMCPS015EOC 600. HMCPS030H1C 600. 150 HMCPS050K2C 760. 45 60 75 90 105 120 135 150 F G 20.7 - 22.9 H 23.0 - 25.2 A B C D 11.5 - 15.2 15.3 - 19.1 200 16.1 - 18.3 18.4 - 20.6 E 19.2 - 22.9 23.0 - 26.8 26.9 - 30.6 F G H 30.7 - 34.5 34.6 - 38.3 38.4 - 42.1 250 300 350 400 450 500 100 A B C D E F G H 23.0 30.7 38.4 46.1 53.8 61.5 69.2 76.9 - 30.6 38.3 46.0 53.7 61.4 69.1 76.8 84.5 300 400 500 600 700 800 900 1000 HMCPS100R3C 915. 4 150 A B C D E F G 34.6 46.1 57.6 69.2 80.7 - 46.0 57.5 69.1 80.6 92.2 450 600 HMCPS150T4C 1,320. HMCPS150U4C 1,320. 4 Table 12-190.600V AC Maximum, 250V DC Maximum NEMA Cont. Cam Motor Starter Amps Setting Full Load Size Current Amps® Price U.S.S 3 Note: HMCP25- 100A come with line and load steel body terminals, 3T100FB. MCPs for Application with Motor Starters Equipped with Electronic Overload Relays 3.4 4.6 5.7 6.9 8.0 9.2 10.4 90 120 150 180 210 240 270 300 E * 115 120 E F A B C D - ;• 109 122 130 139 145 153 A B 55 58 60 A B C D E F G H MCP MCP Trip Catalog Setting Number ® 600. 52 D 100 NEMA Cont. Cam Motor Starter Amps Setting Full Load Current Size Amps ® Price U.S.S Cam Setting 150 H 92.3 -103.7 103.8 -115.2 115.3 -126.7 A B C D E F G 76.0 - 95.0 96.0 -114.0 115.0 -130.7 ® ® ® H 57.0 - 75.0 (4) 750 900 1050 1200 1350 1500 750 1000 1250 1500 1750 2000 2250 2500 ® Motor FLA ranges are typical. The corresponding trip setting is at 13 times the minimum FLA value shown. Where a 13 times setting is required for an intermediate FLA value, alternate cam settings and/or MCP ratings should be used. ® For DC applications, actual trip levels are approximately 40% higher than values shown. ® Settings above 130 amperes are for special applications. NEC Article 430-110(a) requires the ampere rating of the disconnecting means to be not less than 115% of the motor full load ampere rating. Note: Instruction Leaflet/FRED Number 29C401 Note: HMCPS3- 100A come with line and load steel body terminals, 3T100FB. HMCPS 150A come with line and load steel body terminals, 3T150FB. Discount Symbol. For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CB-2 F:T*M Cutler-Hammer Molded Case Circuit Breakers Internal Accessories January 2001 12-163 Vol. I.Ref. No. [0629] Auxiliary Switch Table 12-310. F-Frame Auxiliary Switch Number of Contacts a andb 1 2 Mounting Location (Pole) Left d> Right or Neutral Left I Right or Neutral Factory Mounted Connection Type and Location 18-Inch (457.2 mm) Pigtail Leads Rear ® Same Side Suffix Adder Suffix Adder Number U.S. $ Number U.S. $ A01 A15 « A05 A18* 200. 200. 200. 200. A02 A16® A06 A09 A21S A12 A23 ''J 400. A10 400. A22 ® 400. A13 400. A24 * A19 <* Opposite Side Suffix Adder Number U.S. S 200. A03 200. A17 * 200. A07 200. A20 * 200. 200. 200. Terminal Block Same Side Suffix Adder Number U.S. $ A04 A08 200. All 400. 400. — 400. 400. Field Mounted Field Installation Kits •' Terminal Block Pigtail Leads A14 Catalog Number Price U.S. $ 200. A1X1PK 200. E1X1PK 200. A1X1PK 200. 400. 400. 400. 400. A2X1LPK E2X1LPK A2X1RPK E2X1RPK Catalog Number Price U.S. $ 200. A1X1LTK 201. 200. A1X1RTK® 200. 400. A2X1LTK 400. 400. A2X1RTK i 400. 400. 200. 400. ® Pigtail wire size: 18 AWG (0.82 mm2). @ Not listed with Underwriters Laboratories, for field installation. ® Standard pigtail lead exit location. ® 125V (Max.), 50/60 Hz switch for use in electronic circuit of 100 micro-amp and 15V DC minimum. ® Not for use on 4-pole circuit breakers. Note: Instruction Leaflet/FRED Number 29C120 Table 12-311. J250 Auxiliary Switch Electrical Ratings Volts Frequency Hz 600 125 250 Amperes 50/60 6 DC DC 0.5 0.25 Contact Arrangement Catalog Number Price U.S. $ 1A-1B 2A-2B AUX1A1BPK AUX2A2BPK 200. 400. Note: Instruction Leaflet/FRED Number 29C153 Table 12-312. J-Frame Auxiliary Switch Number of Sets of Contacts daandlb) 1 2 Mounting Location (Pole) Left Right® Left Right* Factory Mounted Connection Type and Location 18-Inch (457.2 mm) Pigtail Leads Rear © Same Side Adder Suffix Adder Suffix Number U.S.S Number U.S.S A01 A05 A09 A12 Opposite Side Suffix Adder Number U.S.S 200. A02 200. A06 200. A03 400. A10 400. A13 400. 400. — 200. A07 " Field Mounted Field Installation Kits 6 Pigtail Leads Terminal Block Terminal Block Same Side Suffix Adder Number U.S.S Catalog Number Price U.S.S Catalog Number Price U.S.S 200. A04 200. A08 200. A1X2PK 200. A1X2PK 200. 200. A1X2RTK * A1X2LTK 200. 200. 400. A11 400. A14 400. A2X2PK 400. A2X2PK 400. A2X2LTK 400. A2X2RTK » 400. 400. ® Listed with Underwriters Laboratories for field installation or interchangeable trip unit breakers under E64983. ® Standard mounting location — leads exit rear of breaker. <s> Not for use on 4-pole circuit breakers. Note: Instruction Leaflet/FRED Number 29C121 Table 12-313. Number of Sets of Contacts (1Mand1B) 1 2 3 K-Frame Auxiliary Switch Mounting Factory Mounted Location Connection Type and Location (Pole) 18-Inch (457.2 mm) Pigtail Leads Rear® Same Side Suffix Adder Suffix Adder Number U.S.S Number U.S.S Left Right® Left Right® Left Right A01 A05 A09 A12 A18 A17 400. 400. A02 A06 A10 A13 600. 600. — 200. 200. 200. 200. 400. 400. Opposite Side Suffix Adder Number U.S.S Terminal Block Same Side Adder Suffix Number U.S.S A03 A04 A07 ——— —— 200. 200. A08 A11 A14 A15 A16 Field Mounted Field Installation Kits " Pigtail Leads Terminal Block Catalog Number Price U.S.S A1X3PK A1X3PK 400. A2X3PK 400. A2X3PK 600. A3X3LPK 600. A3X3RPK 200. 200. Catalog Number Price U.S.S 200. A1X3LTK 200. A1X3RTK® 200. 200. A2X3LTK A2X3RTK ® A3X3LTK A3X3RTK® 400. 400. 400. 400. 610. 610. 600. 600. ® Listed with Underwriters Laboratories for field installation under E64983. ® Standard mounting location — leads exit rear of breaker. ® Not for use on 4-pole circuit breaker. Note: Instruction Leaflet/FRED Number 29C122 Discount Symbol. CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CB-2 E:T*M