® OPERATOR ADAPTER A21WHAMTA Installation Instructions for Westinghouse Type AMT Below−Handle Mechanisms for Disconnect Switches And Circuit Breakers, and Flex Shaft Handle Mechanisms for Circuit Breakers (For parts list, see page 2) For floor−mounted enclosures with disconnect on the right flange, see pages 3−6 Master Door For one through six door free−standing enclosures with the disconnect on the right flange, see pages 7−10 Master Door For floor−mounted enclosures with the disconnect on the centerpost, see pages 11−14 Master Door Rev. B 113357 E 2005 Hoffman Enclosures Inc. P/N 99401965 87569093 WARNING The functions, fits, and clearances of the installation described hereon are calculated from information supplied by the manufactures of the equipment to be installed. Be certain to check the function, fits, and clearances of all equipment both before and after installation to assure that is operates properly and safely and meets all applicable codes, standards, and regulations. In the event the completed installation does not function properly or fails to meet any such codes, standards, or regulations, do not attempt to make alterations or operate the equipment. Report such facts immediately to: Customer Service Dept. Hoffman Enclosures Inc. 2100 Hoffman Way Anoka, MN 55303−1745 (763) 422−2211 PARTS LIST Operator Adapter, Catalog Number A21WHAMTA, Westinghouse Type AMT Below−Handle Mechanisms and Flex Shaft Mechanisms Item No. . . . . . 1 ............ 2 ............ 3 ............ 4 ............ 5 ............ 6 ............ 7 ............ 8 ............ 9 ............ 10 . . . . . . . . . . . 11 . . . . . . . . . . . 12 . . . . . . . . . . . 13 . . . . . . . . . . . 14 . . . . . . . . . . . 15 . . . . . . . . . . . 16 . . . . . . . . . . . 17 . . . . . . . . . . . Part Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adapter Plate, West. AMT . . . . . . . . . . . . . . . . . . Gasket, Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw, 1/4−20x1/2 Pan Head . . . . . . . . . . . . . . . . Slide Arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shoulder Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw, 1/4−20x7/8 Hex Head . . . . . . . . . . . . . . . . Lockwasher 1/4 Spring . . . . . . . . . . . . . . . . . . . . . Washer, Flat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lockwasher 1/4 Int. . . . . . . . . . . . . . . . . . . . . . . . . Nut 1/4−20 Hex . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interlock Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . Screw, 10−32x3/8 Pan Head . . . . . . . . . . . . . . . . Lockwasher, #10 Int. . . . . . . . . . . . . . . . . . . . . . . . Label (extra) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Slide Arm (alternate) . . . . . . . . . . . . . . . . . . . . . . . Plate, Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation Instruction . . . . . . . . . . . . . . . . . . . . . . Part No. . . . . . . . . 26264001 . . . . . . . 26216011 . . . . . . . 99401031 . . . . . . . 26265001 . . . . . . . 26149001 . . . . . . . 99401030 . . . . . . . 99401318 . . . . . . . 22101003 . . . . . . . 99401300 . . . . . . . 99401406 . . . . . . . 26199002 . . . . . . . 99401007 . . . . . . . 99401307 . . . . . . . 26147001 . . . . . . . 26391001 . . . . . . . 27206002 . . . . . . . 99401965 . . . . . . . Quantity 1 1 4 1 1 1 1 2 2 2 1 2 2 1 1 1 1 IMPORTANT NOTES 1. Use adapter plate with mounting studs (item 1) for all below−handle AMT mechanisms and for AMT flex shaft cable mechanisms for F frame circuit breakers. Use Adapter plate without studs (item 16) for all other flex shaft cable mechanisms. 2. Use slide arm (item 4) for all AMT below−handle mechanisms and AMT flex shaft cable mechanisms. Use slide arm (item 15) only for AMT flex shaft mechanisms for F frame circuit breakers. 2 E 2005 Hoffman Enclosures Inc. 87569093 INTRODUCTION Master Door This installation instruction is for Westinghouse Below−Handle AMT and Flex Shaft AMT mechanisms. These mechanisms are for disconnect switches and circuit breakers mounted in Hoffman two door, floor−mounted, enclosures with the disconnect on the right flange. INSTALLATION STEPS Step 1 − Install adapter plate (item 1 or 16) and plate gasket (item 2) on the inside of the enclosure, behind the rectangular opening provided. Secure in place with four screws (item 3). Step 2 − Assemble the Westinghouse “AMTOP” operating handle to the mounting plate which was installed in the enclosure in step 1. Omit cap screw and lockwasher which fits into bottom hole of “AMTOP” operating handle. Step 3 − Install the slide arm (item 4 or 15) over the projecting part of the “AMTOP” operating handle as shown. Note that bottom holes in slide arm are not on center of slide arm. Place the smaller diameter end of the shoulder collar (item 5) through the oval slot in the slide arm. Install long cap screw (item 6) with lockwasher (item 7) through shoulder collar into the bottom mounting hole of the “AMTOP” operating handle and tighten. The slide arm should move up and down smoothly. Install interlock lever extension per Westinghouse instructions. Step 4 − Attach the bottom of the slide arm (item 4 or 15) to the offset arm of the lock release mechanism. Use two flat washers (item 8), two lockwashers (item 9), and two hex nuts (item 10). Do not tighten until parts are adjusted (see step 5B) Step 5 − The handle safety lock release mechanism is adjustable in two places. A) Check the adjustment of the factory installed roller bracket. The door latch should hit against the latch stop portion of the roller bracket when the door is closed and latched. Adjust up or down if necessary. The attached mechanism will then provide the necessary up−down motion required to operate the release mechanism in the “AMTOP” operating handle. B) Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock (in “AMTOP” operating handle) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. Shorten slide arm if safety lock releases too late. Step 6 − Attach the cover interblock blade (item 11), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Used the two screws (item 12) and lockwashers (item 13). The cover interlock blade prevents the door from being opened when the “AMTOP” operating handle is in the “ON” position. This blade may be adjusted up or down to hook properly on the interlock lever extension. The blade (item 11) must be positioned so the bottom edge of blade clears the interlock lever extension by 1/4 inch when “AMTOP” operating handle is in extreme “OFF” position. Step 7 − Drill and tap holes in panel for disconnect required. See table for location of disconnect centerlines. See Westinghouse instructions for location and size of mounting holes. Step 8 − Install panel in enclosure. Step 9 − Mount disconnect switch or circuit breaker on panel using Westinghouse instructions and parts. 87569093 E 2005 Hoffman Enclosures Inc. 3 For Two Door, Floor−Mounted Enclosures With Disconnect on Right Flange 4 E 2005 Hoffman Enclosures Inc. 87569093 For Two Door, Floor−Mounted Enclosures With Disconnect on Right Flange 87569093 E 2005 Hoffman Enclosures Inc. 5 For Two Door, Floor−Mounted Enclosures With Disconnect on Right Flange AMT PIVOT MECHANISM (BELOW−HANDLE) FIXED WIDTH VARIABLE WIDTH WHEN ENCLOSURE IS 60.12” HIGH X X Y Y 30, 60, 100 AMP TYPE DS SWITCH 3.22 5.47 MAX. 9.81 15.81 200 AMP TYPE DS SWITCH 4.63 6.81 MAX. 10.00 16.00 E, EHB, FB, HFB, FB TRI−PAC CIRCUIT BREAKERS MCP (SIZE 0−4) 3.22 5.47 MAX. 9.81 15.81 JB, KB CIRCUIT BREAKERS MCP (250 AMP) 3.22 5.47 MAX. 9.44 15.44 JA, KA, HKA, DA, LB, LBB, HLB, CIRCUIT BREAKERS MCP (400 AMP) 3.22 5.47 MAX. LA, HLA, LC, HLC, LA TRI−PAC CIRCUIT BREAKERS NONE 6.81 MAX. WESTINGHOUSE S G O S DISCONNECT SCO C 6 E 2005 Hoffman Enclosures Inc. WHEN ENCLOSURE IS 72.12” HIGH ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ 9.44 15.44 DO NOT INSTALL 16.75 87569093 INTRODUCTION Master Door This installation instruction is for Westinghouse Below−Handle AMT and Flex Shaft AMT mechanisms. These mechanisms are for disconnect switches and circuit breakers mounted in Hoffman one through six door, free−standing, enclosures with the disconnect on the right flange. INSTALLATION STEPS Step 1 − Install adapter plate (item 1 or 16) and plate gasket (item 2) on the inside of the enclosure, behind the rectangular opening provided. Secure in place with four screws (item 3). Step 2 − Assemble the Westinghouse “AMTOP” operating handle to the mounting plate which was installed in the enclosure in step 1. Omit cap screw and lockwasher which fits into bottom hole of “AMTOP” operating handle. Step 3 − Install the slide arm (item 4 or 15) over the projecting part of the “AMTOP” operating handle as shown. Note that bottom holes in slide arm are not on center of slide arm. Place the smaller diameter end of the shoulder collar (item 5) through the oval slot in the slide arm. Install long cap screw (item 6) with lockwasher (item 7) through shoulder collar into the bottom mounting hole of the “AMTOP” operating handle and tighten. The slide arm should move up and down smoothly. Install interlock lever extension per Westinghouse instructions. Step 4 − Attach the bottom of the slide arm (item 4 or 15) to the offset arm of the lock release mechanism. Use two flat washers (item 8), two lockwashers (item 9), and two hex nuts (item 10). Do not tighten until parts are adjusted (see step 5B) Step 5 − The handle safety lock release mechanism is adjustable in two places. A) Check the adjustment of the factory installed roller bracket. The door latch should hit against the latch stop portion of the roller bracket when the door is closed and latched. Adjust up or down if necessary. The attached mechanism will then provide the necessary up−down motion required to operate the release mechanism in the “AMTOP” operating handle. B) Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock (in “AMTOP” operating handle) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. Shorten slide arm if safety lock releases too late. Step 6 − Attach the cover interblock blade (item 11), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Used the two screws (item 12) and lockwashers (item 13). The cover interlock blade prevents the door from being opened when the “AMTOP” operating handle is in the “ON” position. This blade may be adjusted up or down to hook properly on the interlock lever extension. The blade (item 11) must be positioned so the bottom edge of blade clears the interlock lever extension by 1/4 inch when “AMTOP” operating handle is in extreme “OFF” position. Step 7 − Drill and tap holes in panel for disconnect required. See table for location of disconnect centerlines. See Westinghouse instructions for location and size of mounting holes. Step 8 − Install panel in enclosure. Step 9 − Mount disconnect switch or circuit breaker on panel using Westinghouse instructions and parts. 87569093 E 2005 Hoffman Enclosures Inc. 7 For One Through Six Door, Free−Standing Enclosures With Disconnect on Right Flange 8 E 2005 Hoffman Enclosures Inc. 87569093 For One Through Six Door, Free−Standing Enclosures With Disconnect on Right Flange 87569093 E 2005 Hoffman Enclosures Inc. 9 For One Through Six Door, Free−Standing Enclosures With Disconnect on Right Flange AMT PIVOT MECHANISM (BELOW−HANDLE) FIXED WIDTH VARIABLE WIDTH WHEN ENCLOSURE IS 72.12” HIGH X X Y Y Y 30, 60, 100 AMP TYPE DS SWITCH 3.22 5.47 MAX. 11.81 17.81 20.81 200 AMP TYPE DS SWITCH 4.63 6.81 MAX. 12.00 18.00 21.00 E, EHB, FB, HFB, FB TRI−PAC CIRCUIT BREAKERS MCP (SIZE 0−4) 3.22 5.47 MAX. 11.81 17.81 20.81 JB, KB CIRCUIT BREAKERS MCP (250 AMP) 3.22 5.47 MAX. 11.44 17.44 20.44 JA, KA, HKA, DA, LB, LBB, HLB, CIRCUIT BREAKERS MCP (400 AMP) 3.22 5.47 MAX. 11.44 17.44 20.44 LA, HLA, LC, HLC, LA TRI−PAC CIRCUIT BREAKERS NONE 6.81 MAX. 12.75 18.75 21.75 MA, HMA, MC, HMC, NB, HNB, NC, HNC, NB TRI−PAC CIRCUIT BREAKERS NONE 6.81 MAX. DO NOT INSTALL 18.75 21.75 WESTINGHOUSE S G O S DISCONNECT SCO C 10 ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ E 2005 Hoffman Enclosures Inc. WHEN ENCLOSURE IS 84.12” HIGH WHEN ENCLOSURE IS 90.12” HIGH 87569093 INTRODUCTION Master Door This installation instruction is for Westinghouse Below_Handle AMT and Flex Shaft AMT mechanisms. These mechanisms are for disconnect switches and circuit breakers mounted in Hoffman two door, floor−mounted, enclosures with the disconnect on the centerpost. INSTALLATION STEPS Step 1 − Install adapter plate (item 1 or 16) and plate gasket (item 2) on the inside of the enclosure, behind the rectangular opening provided. Secure in place with four screws (item 3). Step 2 − Assemble the Westinghouse “AMTOP” operating handle to the mounting plate which was installed in the enclosure in step 1. Omit cap screw and lockwasher which fits into bottom hole of “AMTOP” operating handle. Step 3 − Cut 2 1/2 inches off bottom end of slide arm (item 4 or 15). Bottom end of slide arm has rectangular holes only. Step 4 − Install the slide arm (item 4 or 15) over the projecting part of the “AMTOP” operating handle as shown. Note that bottom holes in slide arm are not on center of slide arm. Place the smaller diameter end of the shoulder collar (item 5) through the oval slot in the slide arm. Install long cap screw (item 6) with lockwasher (item 7) through shoulder collar into the bottom mounting hole of the “AMTOP” operating handle and tighten. The slide arm should move up and down smoothly. Install interlock lever extension per Westinghouse instructions. Step 5 − Attach the bottom of the slide arm (item 4 or 15) to the offset arm of the lock release mechanism. Use two flat washers (item 8), two lockwashers (item 9), and two hex nuts (item 10). Do not tighten until parts are adjusted. Step 6 − Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock (in “AMTOP” operating handle) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. shorten slide arm if safety lock releases too late. Step 7 − Attach the cover interblock blade (item 11), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Used the two screws (item 12) and lockwashers (item 13). The cover interlock blade prevents the door from being opened when the “AMTOP” operating handle is in the “ON” position. This blade may be adjusted up or down to hook properly on the interlock lever extension. The blade (item 11) must be positioned so the bottom edge of blade clears the interlock lever extension by 1/4 inch when “AMTOP” operating handle is in extreme “OFF” position. Step 8 − Drill and tap holes in panel for disconnect required. See table for location of disconnect centerlines. See Westinghouse instructions for location and size of mounting holes. Step 9 − Install panel in enclosure. Step 10 − Mount disconnect switch or circuit breaker on panel using Westinghouse instructions and parts. 87569093 E 2005 Hoffman Enclosures Inc. 11 For Two Door, Floor−Mounted Enclosures With Disconnect on Centerpost 12 E 2005 Hoffman Enclosures Inc. 87569093 For Two Door, Floor−Mounted Enclosures With Disconnect on Centerpost 87569093 E 2005 Hoffman Enclosures Inc. 13 For Two Door, Floor−Mounted Enclosures With Disconnect on Centerpost AMT PIVOT MECHANISM (BELOW−HANDLE) FIXED WIDTH VARIABLE WIDTH WHEN ENCLOSURE IS 60.12” HIGH X X Y Y 30, 60, 100 AMP TYPE DS SWITCH 4.72 6.97 MAX. 9.81 15.81 200 AMP TYPE DS SWITCH 6.12 8.31 MAX. 10.00 16.00 E, EHB, FB, HFB, FB TRI−PAC CIRCUIT BREAKERS MCP (SIZE 0−4) 4.72 6.97 MAX. 9.81 15.81 JB, KB CIRCUIT BREAKERS MCP (250 AMP) 4.72 6.97 MAX. 9.44 15.44 JA, KA, HKA, DA, LB, LBB, HLB, CIRCUIT BREAKERS MCP (400 AMP) 4.72 6.97 MAX. LA, HLA, LC, HLC, LA TRI−PAC CIRCUIT BREAKERS NONE 8.31 MAX. WESTINGHOUSE S G O S DISCONNECT SCO C 14 E NIL Hoffman Enclosures Inc. WHEN ENCLOSURE IS 72.12” HIGH ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ 9.44 15.44 DO NOT INSTALL 16.75 87569093 87569093 E 2005 Hoffman Enclosures Inc. 15 ® Hoffman Enclosures Inc. 2100 Hoffman Way Anoka, MN 55303−1745 (763) 422−2211 www.hoffmanonline.com Pentair Electronic Packaging 170 Commerce Drive Warwick, RI 02886 (401) 732−3770 www.pentair−ep.com Mexico Pentair Enclosures, S. de R.L. de C.V. Federico T. de la Chica No. 8 Piso 4 A Circuito Comercial Plaza Satélite Ciudad Satélite, Naucalpan, México C.P. 53100 011−52−55−5393−8263 Canada Hoffman−Schroff 111 Grangeway Avenue, Suite 504 Scarborough, Ontario M1H 3E9 (416) 289−2770 1−800−668−2500 (Canada only) Germany Schroff GmbH Langenalber Str. 96−100 75334 Straubenhardt 49 (07082) 794−0 www.schroff.de Great Britain Schroff UK Ltd. Maylands Avenue Hemel Hempstead, Herts HP2 7DE 44 (01442) 240471 www.schroff.co.uk Sweden Schroff Scandinavia AB Box 2003 12821 Skarpnäck 46 08683 61 00 www.schroff.se France Schroff Sas Z.I., 4 rue du Marais 67660 Betschdorf 33 03 88 90 64 90 www.schroff.fr Italy Schroff srl Viale Milano, 119 21013 Gallarate (Varese) 39 0331 79 40 03 Singapore Hoffman−Schroff Pte. Ltd. #01−68/71 German Centre 25 International Business Park Singapore 609916 65 5 62−78 90 Japan Schroff K.K. Nisso No. 13 Bldg. 4F 2−5−1 Shinyokohama Kohoku−Ku, Yokohama shi Kanagawa 222−0033 81 (045) 476−02 81 Finland Schroff Scandinavia AB Peräsimentie 8 03100 Nummela 358 09 222 68 00 Norway Schroff Scandinavia AB Bjoernerudveien 24 1266 Oslo 47 022 76 33 60 16 E 2005 Hoffman Enclosures Inc. 87569093