emc test report

advertisement
Test Report issued under the responsibility of:
EMC TEST REPORT
EN 301 489-7
Electromagnetic Compatibility for radio equipment and services –
mobile and portable radio and ancillary equipment
Report Reference No. ..................... :
G0M-1103-1037 – E-13
Testing Laboratory ......................... :
Eurofins Product Service GmbH
Address............................................. :
Storkower Str. 38c
15526 Reichenwalde
Germany
Accreditation ..................................... :
DAkkS - Registration number : D-PL-12092-01-01
Applicant’s name ............................ :
Falcom Wireless Communications GmbH
Address............................................. :
Gewerbering 6
98704 Langewiesen
Germany
Test specification:
According to RTTE directive 1995/5/EC
Standard ........................................... :
EN 301 489-7 V1.3.1:2005-11
EN 301 489-1 V1.8.1:2008-04
Non-standard test method…………..:
None
Test scope………….. ........................ :
complete EMC compliance test
Equipment under test (EUT):
Product description. .......................... :
Tracking solution
Model No. ......................................... :
Bolero-LT2
Hardware Version ............................. :
Rev. 01c
Software / Firmware Version ............ :
10.00.003
Test result
Passed
Test Report No.: G0M-1103-1037–E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 1 of 23
REPORT INDEX
1 EQUIPMENT (TEST ITEM) DESCRIPTION
4 1.1 Equipment photos
5 1.2 Input / Output Ports
6 1.3 Supporting Equipment Used During Testing
7 1.4 Test Equipment Used During Testing
8 1.5 EUT Operation Modes
10 1.6 Immunity Performance Criteria
11 2 RESULT SUMMARY
13 3 TEST CONDITIONS AND RESULTS
14 3.1 Test Conditions and Results – Conducted emissions
14 3.2 Test Conditions and Results – Immunity to RF electromagnetic fields
18 3.3 Test Conditions and Results – Immunity to conducted disturbances
20 3.4 Test Conditions and Results – Transients and surges in the vehicular environment
22 Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 3 of 23
1
Equipment (Test item) Description
Description
Tracking solution
Model
Bolero-LT2
Serial number
30641(101)08100002
Hardware version
Rev. 01c
Software version
10.00.003
Manufacturer
FMO Electronics GmbH
Ratings / Power supply
12VDC
Number of tested samples
1
Device classification
EN 301 489-1
Vehicular use
Device classification
EN 301 489-7
Equipment without analogue speech circuits
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 4 of 23
1.1
Equipment photos
EUT TOP
EUT BOTTOM
EUT OPEN
EUT PCB TOP
EUT PCB BOTTOM
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 5 of 23
1.2
Input / Output Ports
Port #
Name
Type*
0
DC-Power
DC
Max. Cable
Length
Cable
Shielded
Comments
*Note: Use the following abbreviations:
AC : AC power port
DC : DC power port
N/E : Non electrical
I/O : Signal input or output port
TP : Telecommunication port
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 6 of 23
1.3
Supporting Equipment Used During Testing
Product
Type*
Device
Manufacturer
Model No.
AE
Communication Tester
Rohde & Schwarz
CMU 200
Comments
*Note: Use the following abbreviations:
AE : Auxiliary/Associated Equipment, or
SIM : Simulator (Not Subjected to Test)
CABL : Connecting cables
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 7 of 23
1.4
Test Equipment Used During Testing
Conducted emissions
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
Current probe
R&S
EZ-17
Inv. No. 0347
Sep 09
Sep 11
Absorbing Clamp
R&S
MDS 21
Inv. No. 0039
Oct 09
Oct 11
ISN
R&S
ENY41
Inv. No. 0428
Apr 10
Apr 12
AMN
R&S
ESH2-Z5
Inv. No. 0288
Sep 10
Sep 12
LISN
Schwarzbeck
NNBM 8125
Inv. No. 0044
Jun 11
Jun 12
LISN
Schwarzbeck
NNBM 8126D
Inv. No. 0045
May 11
May 13
AMN
R&S
ESH3-Z5
Inv. No. 0040
Nov 10
Nov 12
EMI Test Receiver
R&S
ESCS 30
Inv. No. 0476
Jun 11
Jun 12
Radiated immunity
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
Generator
R&S
SME06
Inv. No. 0100
Oct 09
Oct 11
Amplifier
Amplifier
Research
100W1000M1
Inv. No. 0237
System
calibration
Amplifier
Amplifier
Research
60S1G3
Inv. No. 0448
System
calibration
Antenna
Frankonia
BTA-H
Inv. No. 0472
System
calibration
Horn antenna
Schwarzbeck
BBHA 9120C
Inv. No. 0019
Aug 06
Aug 11
Millivoltmeter
R&S
URV55
Inv. No. 0348
May 11
May 12
Directional Coupler
MEB
RK100
Inv. No. 0372
System
calibration
Directional Coupler
Narda
3002-20
Inv. No. 0145
System
calibration
EMI Receiver
R&S
ESCS30
Inv. No. 0474
Jun 11
Jun 12
Conducted immunity
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
EMI Test Receiver
R&S
ESCS 30
Inv. No. 0474
Jun 11
Jun 12
Generator
R&S
SMG
Inv. No. 0224E
Jul 11
Jul 12
Amplifier
Amplifier
Research
75A250
Inv. No. 0300
System
calibration
Directional Coupler
Amplifier
Research
DC3001
Inv. No. 0373
System
calibration
CDN
MEB
M3-801/6
Inv. No. 0102
System
calibration
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 8 of 23
Transients and surges in the vehicular environment
Description
Manufacturer
Model
Identifier
Cal. Date
Cal. Due
Ultra Compact
Simulator
EM-Test
UCS200M
Inv. No. 0244
Apr 09
Apr 12
Voltage Drop
Simulator
EM-Test
VDS200
Inv. No. 0246
Apr 09
Apr 12
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 9 of 23
1.5
Mode #
EUT Operation Modes
Description
Active GSM link to EUT with Communication Tester
1
Monitored parameters (Immunity testing): Link maintenance, Link Quality
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 10 of 23
1.6
Immunity Performance Criteria
The test results shall be classified in terms of the loss of function or degradation of performance of the
equipment under test, relative to a performance level defined by its manufacturer or the requestor of
the test, or agreed between the manufacturer and the purchaser of the product.
Definition related to the performance level:
based on the used product standard
based on the declaration of the manufacturer, requestor or purchaser
Criterion for continuous phenomena according to EN 301 489-7:
Mode
Acceptable level of performance
Transmitter (CT)
A communication link shall be established at the start of the test, and maintained
during the test.
At the conclusion of the test, the EUT shall operate as intended with no loss of
user control functions or stored data, and the communication link shall have been
maintained. In addition to confirming the above performance during a call, the
test shall also be performed in idle mode, and the transmitter shall not
unintentionally operate.
Receiver (CR)
A communications link shall be established at the start of the test.
During the test, the RXQUAL of the downlink shall not exceed the value of three,
measured during each individual exposure in the test sequence.
At the conclusion of the test, the EUT shall operate as intended with no loss of
user control functions or stored data, and the communication link shall have been
maintained.
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 11 of 23
Criterion for transient phenomena according to EN 301 489-7:
Mode
Acceptable level of performance
Transmitter (TT)
A communications link shall be established at the start of the test.
At the conclusion of each exposure the EUT shall operate with no user noticeable
loss of the communication link.
At the conclusion of the total test comprising the series of individual exposures,
the EUT shall operate as intended with no loss of user control functions or stored
data, as declared by the manufacturer, and the communication link shall have
been maintained.
In addition to confirming the above performance during a call, the test shall also
be performed in idle mode, and the transmitter shall not unintentionally operate.
Receiver (TR)
A communications link shall be established at the start of the test.
At the conclusion of each exposure the EUT shall operate with no user noticeable
loss of the communication link.
At the conclusion of the total test comprising the series of individual exposures,
the EUT shall operate as intended with no loss of user control functions or stored
data, as declared by the manufacturer, and the communication link shall have
been maintained.
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 12 of 23
2
Result Summary
EN 301 489-7, EN 301 489-1
Product Specific
Standard
Requirement – Test
Reference
Method
Result
Remarks
EN 55016-2-3:2006
N/R
Test acc. to relevant radio
product standard.
See G0M-1103-1037-T-51
EN 55022:2006
PASS
EN 61000-3-2/A1:2006
N/R
See EN 61000-3-2
section 7
See EN 61000-3-3
section 6.1
EN 301 489-7
Section 7.1
Radiated emissions of enclosure of ancillary
equipment measured on a standalone basis
EN 301 489-7
Section 7.1
Conducted emissions
EN 301 489-7
Section 7.1
Harmonic current emissions
EN 301 489-7
Section 7.1
Voltage fluctuations and flicker
EN 61000-3-3:1995
N/R
EN 301 489-7
Section 7.2
Radio frequency electromagnetic field
EN 61000-4-3:2006
PASS
EN 301 489-7
Section 7.2
Radio frequency, common mode
EN 61000-4-6:2005
PASS
EN 301 489-7
Section 7.2
Electrostatic discharge
EN 61000-4-2:2001
N/R
Vehicular use
EN 301 489-7
Section 7.2
Fast transients, common mode
EN 61000-4-4:2004
N/R
Vehicular use
EN 301 489-7
Section 7.2
Transients and surges in the vehicular
environment
ISO 7637-2:2004
PASS
EN 301 489-7
Section 7.2
Surges
EN 61000-4-5:2006
N/R
Vehicular use
EN 301 489-7
Section 7.2
Voltage dips and interruptions
EN 61000-4-11:2004
N/R
Vehicular use
Remarks:
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 13 of 23
3
3.1
Test Conditions and Results
Test Conditions and Results – Conducted emissions
Conducted emissions acc. to EN 301 489-7
Verdict: PASS
Laboratory Parameters:
Required prior to the test
During the test
Ambient Temperature
15 to 35°C
23°C
Relative Humidity
30 to 60%
48%
Test according to referenced
standards
Common Part
Reference Method
EN 301 489-1
EN 55022
Frequency range
Fully configured sample scanned
over the following frequency range
0.15MHz to 30MHz
Points of Application
Application Interface
DC-Power
LISN
EUT operating mode
1
Limits and results
Frequency [MHz]
Quasi-Peak [dBµV]
Result
Average [dBµV]
Result
0.15 to 0.5
66 – 56
PASS
56 – 46
PASS
0.5 to 5
56
PASS
46
PASS
5 to 30
60
PASS
50
PASS
Comments:
The limit decreases linearly with the logarithm of the frequency in the range 0.15 to 0.5MHz.
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 14 of 23
Test setup
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 15 of 23
EMI voltage test in the dc-mains according to EN 55022
Order number: G0M-1103-1037
Manufacturer:
EUT Name:
Model:
Test Site:
Operator:
Test Conditions:
LISN:
Mode:
Test Date:
Note:
Falcom Wireless Communications
Automotive Vehicle Locations Solutions
Bolero-LT2
Eurofins Product Service GmbH
Mr. Marquardt
Tnom: 23°C, Unom: 13.5 VDC
NNBM 8126D (+)
GPRS 900MHz PCL5, GPS
28.06.2011
Index 9
80
EN 55022 AV Voltage Class B
RBW: 9 kHz, Line 1 Max Peak
EN 55022 QP Voltage Class B
RBW: 9 kHz, Line 1 Max Average
70
60
Voltage (dBµV)
50
40
30
20
10
0
-10
-20
150 k
300 k
600 k
1000 k
2M
3M
5M
10 M
20 M
30 M
Frequency (Hz)
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 16 of 23
EMI voltage test in the dc-mains according to EN 55022
Order number: G0M-1103-1037
Manufacturer:
EUT Name:
Model:
Test Site:
Operator:
Test Conditions:
LISN:
Mode:
Test Date:
Note:
Falcom Wireless Communications
Automotive Vehicle Locations Solutions
Bolero-LT2
Eurofins Product Service GmbH
Mr. Marquardt
Tnom: 23°C, Unom: 13.5 VDC
NNBM 8125 (-)
GPRS 900MHz PCL5, GPS
28.06.2011
Index 10
80
EN 55022 AV Voltage Class B
RBW: 9 kHz, Neutral Max Peak
EN 55022 QP Voltage Class B
RBW: 9 kHz, Neutral Max Average
70
60
Voltage (dBµV)
50
40
30
20
10
0
-10
-20
150 k
300 k
600 k
1000 k
2M
3M
5M
10 M
20 M
30 M
Frequency (Hz)
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 17 of 23
3.2
Test Conditions and Results – Immunity to RF electromagnetic fields
Immunity to RF electromagnetic fields acc. to EN 301 489-7
Verdict: PASS
Laboratory Parameters:
Required prior to the test
During the test
Ambient Temperature
15 to 35°C
23°C
Relative Humidity
30 to 60%
48%
Test according to referenced
standards
Common Part
Reference Method
EN 301 489-1
EN 61000-4-3
Frequency range
Fully configured sample scanned
over the following frequency range
80MHz to 2.7GHz
Samples tested on the following
number of orientations
Number of orientations
EUT operating mode
1
4
Test parameters and results
Frequency [MHz]
Test level
[V/m]
Modulation
Frequency
step
Dwell time
Result
Criterion
80 – 1000
3
80% AM 1kHz
1%
2s
PASS
CT&CR
1400 – 2700
3
80% AM 1kHz
1%
2s
PASS
CT&CR
Comments:
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 18 of 23
Test setup
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 19 of 23
3.3
Test Conditions and Results – Immunity to conducted disturbances
Immunity to conducted disturbances acc. to EN 301 489-7
Verdict: PASS
Laboratory Parameters:
Required prior to the test
During the test
Ambient Temperature
15 to 35°C
23°C
Relative Humidity
30 to 60%
48%
Test according to referenced
standards
Common Part
Reference Method
EN 301 489-1
EN 61000-4-6
Frequency range
Fully configured sample scanned
over the following frequency range
0.15MHz to 80MHz
Points of Application
Application interface
DC-Power
CDN
EUT operating mode
1
Test parameters and results
Frequency [MHz]
Test Port
Test level
[V]
Modulation
Frequency
step
Dwell time
Result
Criterion
0.15 - 80
DC-Power
3
80% AM 1kHz
1%
2s
PASS
CT&CR
Comments:
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 20 of 23
Test setup
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 21 of 23
3.4
Test Conditions and Results – Transients and surges in the vehicular environment
Transients and surges in the vehicular environment acc. to
EN 301 489-7
Verdict: PASS
Laboratory Parameters:
Required prior to the test
During the test
Ambient Temperature
15 to 35°C
23°C
Relative Humidity
30 to 60%
48%
Test according to referenced
standards
Common Part
Reference Method
EN 301 489-1
ISO 7637-2
EUT operating mode
1
Test parameters and results
Test Pulse
Test level
Duration
Result
Criterion
1*
III
10 pulse
PASS
TT&TR
2a*
III
10 pulse
PASS
TT&TR
2b*
III
10 pulse
PASS
TT&TR
3a
III
20 min
PASS
CT&CR
3b
III
20 min
PASS
CT&CR
4*
III
10 pulse
PASS
TT&TR
Comments:
* communication link need not to be maintained during the EMC exposure and may have to be re-established.
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 22 of 23
Test setup
Test Report No.: G0M-1103-1037-E-13
Eurofins Product Service GmbH
Storkower Str. 38c, D-15526 Reichenwalde, Germany
Page 23 of 23
Download