Test Report issued under the responsibility of: EMC TEST REPORT EN 301 489-7 Electromagnetic Compatibility for radio equipment and services – mobile and portable radio and ancillary equipment Report Reference No. ..................... : G0M-1103-1037 – E-13 Testing Laboratory ......................... : Eurofins Product Service GmbH Address............................................. : Storkower Str. 38c 15526 Reichenwalde Germany Accreditation ..................................... : DAkkS - Registration number : D-PL-12092-01-01 Applicant’s name ............................ : Falcom Wireless Communications GmbH Address............................................. : Gewerbering 6 98704 Langewiesen Germany Test specification: According to RTTE directive 1995/5/EC Standard ........................................... : EN 301 489-7 V1.3.1:2005-11 EN 301 489-1 V1.8.1:2008-04 Non-standard test method…………..: None Test scope………….. ........................ : complete EMC compliance test Equipment under test (EUT): Product description. .......................... : Tracking solution Model No. ......................................... : Bolero-LT2 Hardware Version ............................. : Rev. 01c Software / Firmware Version ............ : 10.00.003 Test result Passed Test Report No.: G0M-1103-1037–E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 1 of 23 REPORT INDEX 1 EQUIPMENT (TEST ITEM) DESCRIPTION 4 1.1 Equipment photos 5 1.2 Input / Output Ports 6 1.3 Supporting Equipment Used During Testing 7 1.4 Test Equipment Used During Testing 8 1.5 EUT Operation Modes 10 1.6 Immunity Performance Criteria 11 2 RESULT SUMMARY 13 3 TEST CONDITIONS AND RESULTS 14 3.1 Test Conditions and Results – Conducted emissions 14 3.2 Test Conditions and Results – Immunity to RF electromagnetic fields 18 3.3 Test Conditions and Results – Immunity to conducted disturbances 20 3.4 Test Conditions and Results – Transients and surges in the vehicular environment 22 Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 3 of 23 1 Equipment (Test item) Description Description Tracking solution Model Bolero-LT2 Serial number 30641(101)08100002 Hardware version Rev. 01c Software version 10.00.003 Manufacturer FMO Electronics GmbH Ratings / Power supply 12VDC Number of tested samples 1 Device classification EN 301 489-1 Vehicular use Device classification EN 301 489-7 Equipment without analogue speech circuits Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 4 of 23 1.1 Equipment photos EUT TOP EUT BOTTOM EUT OPEN EUT PCB TOP EUT PCB BOTTOM Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 5 of 23 1.2 Input / Output Ports Port # Name Type* 0 DC-Power DC Max. Cable Length Cable Shielded Comments *Note: Use the following abbreviations: AC : AC power port DC : DC power port N/E : Non electrical I/O : Signal input or output port TP : Telecommunication port Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 6 of 23 1.3 Supporting Equipment Used During Testing Product Type* Device Manufacturer Model No. AE Communication Tester Rohde & Schwarz CMU 200 Comments *Note: Use the following abbreviations: AE : Auxiliary/Associated Equipment, or SIM : Simulator (Not Subjected to Test) CABL : Connecting cables Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 7 of 23 1.4 Test Equipment Used During Testing Conducted emissions Description Manufacturer Model Identifier Cal. Date Cal. Due Current probe R&S EZ-17 Inv. No. 0347 Sep 09 Sep 11 Absorbing Clamp R&S MDS 21 Inv. No. 0039 Oct 09 Oct 11 ISN R&S ENY41 Inv. No. 0428 Apr 10 Apr 12 AMN R&S ESH2-Z5 Inv. No. 0288 Sep 10 Sep 12 LISN Schwarzbeck NNBM 8125 Inv. No. 0044 Jun 11 Jun 12 LISN Schwarzbeck NNBM 8126D Inv. No. 0045 May 11 May 13 AMN R&S ESH3-Z5 Inv. No. 0040 Nov 10 Nov 12 EMI Test Receiver R&S ESCS 30 Inv. No. 0476 Jun 11 Jun 12 Radiated immunity Description Manufacturer Model Identifier Cal. Date Cal. Due Generator R&S SME06 Inv. No. 0100 Oct 09 Oct 11 Amplifier Amplifier Research 100W1000M1 Inv. No. 0237 System calibration Amplifier Amplifier Research 60S1G3 Inv. No. 0448 System calibration Antenna Frankonia BTA-H Inv. No. 0472 System calibration Horn antenna Schwarzbeck BBHA 9120C Inv. No. 0019 Aug 06 Aug 11 Millivoltmeter R&S URV55 Inv. No. 0348 May 11 May 12 Directional Coupler MEB RK100 Inv. No. 0372 System calibration Directional Coupler Narda 3002-20 Inv. No. 0145 System calibration EMI Receiver R&S ESCS30 Inv. No. 0474 Jun 11 Jun 12 Conducted immunity Description Manufacturer Model Identifier Cal. Date Cal. Due EMI Test Receiver R&S ESCS 30 Inv. No. 0474 Jun 11 Jun 12 Generator R&S SMG Inv. No. 0224E Jul 11 Jul 12 Amplifier Amplifier Research 75A250 Inv. No. 0300 System calibration Directional Coupler Amplifier Research DC3001 Inv. No. 0373 System calibration CDN MEB M3-801/6 Inv. No. 0102 System calibration Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 8 of 23 Transients and surges in the vehicular environment Description Manufacturer Model Identifier Cal. Date Cal. Due Ultra Compact Simulator EM-Test UCS200M Inv. No. 0244 Apr 09 Apr 12 Voltage Drop Simulator EM-Test VDS200 Inv. No. 0246 Apr 09 Apr 12 Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 9 of 23 1.5 Mode # EUT Operation Modes Description Active GSM link to EUT with Communication Tester 1 Monitored parameters (Immunity testing): Link maintenance, Link Quality Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 10 of 23 1.6 Immunity Performance Criteria The test results shall be classified in terms of the loss of function or degradation of performance of the equipment under test, relative to a performance level defined by its manufacturer or the requestor of the test, or agreed between the manufacturer and the purchaser of the product. Definition related to the performance level: based on the used product standard based on the declaration of the manufacturer, requestor or purchaser Criterion for continuous phenomena according to EN 301 489-7: Mode Acceptable level of performance Transmitter (CT) A communication link shall be established at the start of the test, and maintained during the test. At the conclusion of the test, the EUT shall operate as intended with no loss of user control functions or stored data, and the communication link shall have been maintained. In addition to confirming the above performance during a call, the test shall also be performed in idle mode, and the transmitter shall not unintentionally operate. Receiver (CR) A communications link shall be established at the start of the test. During the test, the RXQUAL of the downlink shall not exceed the value of three, measured during each individual exposure in the test sequence. At the conclusion of the test, the EUT shall operate as intended with no loss of user control functions or stored data, and the communication link shall have been maintained. Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 11 of 23 Criterion for transient phenomena according to EN 301 489-7: Mode Acceptable level of performance Transmitter (TT) A communications link shall be established at the start of the test. At the conclusion of each exposure the EUT shall operate with no user noticeable loss of the communication link. At the conclusion of the total test comprising the series of individual exposures, the EUT shall operate as intended with no loss of user control functions or stored data, as declared by the manufacturer, and the communication link shall have been maintained. In addition to confirming the above performance during a call, the test shall also be performed in idle mode, and the transmitter shall not unintentionally operate. Receiver (TR) A communications link shall be established at the start of the test. At the conclusion of each exposure the EUT shall operate with no user noticeable loss of the communication link. At the conclusion of the total test comprising the series of individual exposures, the EUT shall operate as intended with no loss of user control functions or stored data, as declared by the manufacturer, and the communication link shall have been maintained. Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 12 of 23 2 Result Summary EN 301 489-7, EN 301 489-1 Product Specific Standard Requirement – Test Reference Method Result Remarks EN 55016-2-3:2006 N/R Test acc. to relevant radio product standard. See G0M-1103-1037-T-51 EN 55022:2006 PASS EN 61000-3-2/A1:2006 N/R See EN 61000-3-2 section 7 See EN 61000-3-3 section 6.1 EN 301 489-7 Section 7.1 Radiated emissions of enclosure of ancillary equipment measured on a standalone basis EN 301 489-7 Section 7.1 Conducted emissions EN 301 489-7 Section 7.1 Harmonic current emissions EN 301 489-7 Section 7.1 Voltage fluctuations and flicker EN 61000-3-3:1995 N/R EN 301 489-7 Section 7.2 Radio frequency electromagnetic field EN 61000-4-3:2006 PASS EN 301 489-7 Section 7.2 Radio frequency, common mode EN 61000-4-6:2005 PASS EN 301 489-7 Section 7.2 Electrostatic discharge EN 61000-4-2:2001 N/R Vehicular use EN 301 489-7 Section 7.2 Fast transients, common mode EN 61000-4-4:2004 N/R Vehicular use EN 301 489-7 Section 7.2 Transients and surges in the vehicular environment ISO 7637-2:2004 PASS EN 301 489-7 Section 7.2 Surges EN 61000-4-5:2006 N/R Vehicular use EN 301 489-7 Section 7.2 Voltage dips and interruptions EN 61000-4-11:2004 N/R Vehicular use Remarks: Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 13 of 23 3 3.1 Test Conditions and Results Test Conditions and Results – Conducted emissions Conducted emissions acc. to EN 301 489-7 Verdict: PASS Laboratory Parameters: Required prior to the test During the test Ambient Temperature 15 to 35°C 23°C Relative Humidity 30 to 60% 48% Test according to referenced standards Common Part Reference Method EN 301 489-1 EN 55022 Frequency range Fully configured sample scanned over the following frequency range 0.15MHz to 30MHz Points of Application Application Interface DC-Power LISN EUT operating mode 1 Limits and results Frequency [MHz] Quasi-Peak [dBµV] Result Average [dBµV] Result 0.15 to 0.5 66 – 56 PASS 56 – 46 PASS 0.5 to 5 56 PASS 46 PASS 5 to 30 60 PASS 50 PASS Comments: The limit decreases linearly with the logarithm of the frequency in the range 0.15 to 0.5MHz. Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 14 of 23 Test setup Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 15 of 23 EMI voltage test in the dc-mains according to EN 55022 Order number: G0M-1103-1037 Manufacturer: EUT Name: Model: Test Site: Operator: Test Conditions: LISN: Mode: Test Date: Note: Falcom Wireless Communications Automotive Vehicle Locations Solutions Bolero-LT2 Eurofins Product Service GmbH Mr. Marquardt Tnom: 23°C, Unom: 13.5 VDC NNBM 8126D (+) GPRS 900MHz PCL5, GPS 28.06.2011 Index 9 80 EN 55022 AV Voltage Class B RBW: 9 kHz, Line 1 Max Peak EN 55022 QP Voltage Class B RBW: 9 kHz, Line 1 Max Average 70 60 Voltage (dBµV) 50 40 30 20 10 0 -10 -20 150 k 300 k 600 k 1000 k 2M 3M 5M 10 M 20 M 30 M Frequency (Hz) Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 16 of 23 EMI voltage test in the dc-mains according to EN 55022 Order number: G0M-1103-1037 Manufacturer: EUT Name: Model: Test Site: Operator: Test Conditions: LISN: Mode: Test Date: Note: Falcom Wireless Communications Automotive Vehicle Locations Solutions Bolero-LT2 Eurofins Product Service GmbH Mr. Marquardt Tnom: 23°C, Unom: 13.5 VDC NNBM 8125 (-) GPRS 900MHz PCL5, GPS 28.06.2011 Index 10 80 EN 55022 AV Voltage Class B RBW: 9 kHz, Neutral Max Peak EN 55022 QP Voltage Class B RBW: 9 kHz, Neutral Max Average 70 60 Voltage (dBµV) 50 40 30 20 10 0 -10 -20 150 k 300 k 600 k 1000 k 2M 3M 5M 10 M 20 M 30 M Frequency (Hz) Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 17 of 23 3.2 Test Conditions and Results – Immunity to RF electromagnetic fields Immunity to RF electromagnetic fields acc. to EN 301 489-7 Verdict: PASS Laboratory Parameters: Required prior to the test During the test Ambient Temperature 15 to 35°C 23°C Relative Humidity 30 to 60% 48% Test according to referenced standards Common Part Reference Method EN 301 489-1 EN 61000-4-3 Frequency range Fully configured sample scanned over the following frequency range 80MHz to 2.7GHz Samples tested on the following number of orientations Number of orientations EUT operating mode 1 4 Test parameters and results Frequency [MHz] Test level [V/m] Modulation Frequency step Dwell time Result Criterion 80 – 1000 3 80% AM 1kHz 1% 2s PASS CT&CR 1400 – 2700 3 80% AM 1kHz 1% 2s PASS CT&CR Comments: Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 18 of 23 Test setup Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 19 of 23 3.3 Test Conditions and Results – Immunity to conducted disturbances Immunity to conducted disturbances acc. to EN 301 489-7 Verdict: PASS Laboratory Parameters: Required prior to the test During the test Ambient Temperature 15 to 35°C 23°C Relative Humidity 30 to 60% 48% Test according to referenced standards Common Part Reference Method EN 301 489-1 EN 61000-4-6 Frequency range Fully configured sample scanned over the following frequency range 0.15MHz to 80MHz Points of Application Application interface DC-Power CDN EUT operating mode 1 Test parameters and results Frequency [MHz] Test Port Test level [V] Modulation Frequency step Dwell time Result Criterion 0.15 - 80 DC-Power 3 80% AM 1kHz 1% 2s PASS CT&CR Comments: Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 20 of 23 Test setup Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 21 of 23 3.4 Test Conditions and Results – Transients and surges in the vehicular environment Transients and surges in the vehicular environment acc. to EN 301 489-7 Verdict: PASS Laboratory Parameters: Required prior to the test During the test Ambient Temperature 15 to 35°C 23°C Relative Humidity 30 to 60% 48% Test according to referenced standards Common Part Reference Method EN 301 489-1 ISO 7637-2 EUT operating mode 1 Test parameters and results Test Pulse Test level Duration Result Criterion 1* III 10 pulse PASS TT&TR 2a* III 10 pulse PASS TT&TR 2b* III 10 pulse PASS TT&TR 3a III 20 min PASS CT&CR 3b III 20 min PASS CT&CR 4* III 10 pulse PASS TT&TR Comments: * communication link need not to be maintained during the EMC exposure and may have to be re-established. Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 22 of 23 Test setup Test Report No.: G0M-1103-1037-E-13 Eurofins Product Service GmbH Storkower Str. 38c, D-15526 Reichenwalde, Germany Page 23 of 23