ELECTRICAL PRODUCTS Industrial Fuses slo-blo® rk5 fuses • A popular fuse for service entrance, main, feeder and general-purpose branch circuits up to 600 amp. • Excellent choice for circuits with high in rush currents, motors, transformers, solenoids, fluorescent lights. • Provides excellent overload and effective short circuit protection for most National Electrical Code applications. • Reliable interruption of all overcurrents up to 200,000 amp; minimizes need for short circuit calculations. • Reduces damage caused by heating and magnetic effects of short-circuit currents. • 10 seconds minimum time delay at 500% rating eliminates needless downtime caused by power surges or equipment demands. • Separate spring loaded, thermal overload element is non-fatiguing and­­thermally reversible. • Low resistance design reduces power consumption and utility bills. klkr series midget class cc 600 V fast acting type fuse • Used for the protection of heating, lighting and other non-inductive circuits. • Provides current-limiting short circuit protection. • Provides overload protection for non-inductive loads. SPECIFICATIONS: • Interrupting Rating: 200,000 amp rms symmetrical • Approvals: UL listed and CSA certified • Fuse Dimensions: 13/32" x 1-1/2" with a rejection feature added to the fuse cap Part No. Bussman Ref. No. Littelfuse Ref. No. Amps Qty. 69538-5 KTK-R-15 KLK-R-15 15 1 E50 slo-blo® RK5 Fls-r class Fuse Dual element time delay 600 V SPECIFICATIONS: 250 V slo-blo® type flm class cc fuse • Used on circuits with high in rush currents. • Voltage Ratings: A C: 600 V (FLS-R) • DC: 300 V (FLS-R) • Amp Ratings: 1/10 - 600 amp • Approvals: AC: UL Listed Class RK5 fuse per UL 198E, CSA Certified HRCI-R • DC: FLS-R: MSHA 300 V listing, Federal Specification No. WF1814 (QPL) SPECIFICATIONS: • Approvals: UL Listed CSA Certified. • Interrupting Rating: 10,000 amp at 250 VAC. • Fuses to MIL specs: F09B type. • Fuse dimensions: 13/32" diameter, 1-1/2" length. Electrical Characteristics: Part No. Bussman Ref. No. Littelfuse Ref. No. Amps Qty. 69336-5 69340-5 FRS-R-15 FRS-R-30 FLS-R-15 FLS-R-30 15 30 1 1 • Percent of Amp Rating / Opening Time »» 110% / 4 hours minimum »» 135% / 1 hour maximum »» 200% / 12 seconds maximum Part No. Bussman Ref. No. Littelfuse Ref. No. Amps Qty. 69399-5 FNM-30 FLM-30 30 1 slo-blo® RK5 Fls-r class Fuse Dual element time delay 250 volt SPECIFICATIONS: • Voltage Ratings: AC: 250 V (FLN-R), DC: 125 V (FLN-R) • Amp Ratings: 1/10-600 amp • Approvals: AC: UL Listed Class RK5 fuse per UL 198E, CSA Certified HRCI-R • DC: FLN-R: UL listed 125 V per UL 198L, Federal Specification No. WF1814 (QPL) Part No. Bussman Ref. No. Littelfuse Ref. No. Amps Qty. 69465-5 69470-5 FRN-R-30 FRN-R-60 FLN-R-30 FLN-R-60 30 60 1 1 FNQ-R Fuses DUAL ELEMENT TIME DELAY 600 V SPECIFICATIONS: • Voltage Ratings: AC: 600 V, DC: 250 V (CCMR2/10-2A, CCMR4-1/210A, CCMR35-60A), 300 V (CCMR2-1/4-4A), 500 V CCMR12-30A) • Amp Ratings: 2/10 – 60 amp • Approvals: AC: UL Listed Time-Delay Class CC fuses per UL 248 2/10-30A, CSA Certified, HRCI-MISC 30-6I0A, UL Listed Class CD • Physical Size: 13/32" x 1-1/2" Part No. Bussman Ref. No. Littelfuse Ref. No. Amps Qty. 69433-5 FNQ-R-15 CCM-R-15 15 1 KLDR Series - Class CC Time-Delay Fuse For Transformers • For the protection of control transformers, solenoids and similar inductive components with high magnetizing currents during the first half-cycle. • Plastic construction to prevent shock. • Used for a wide range and style of cartridge fuses. SPECIFICATIONS: • Voltage Ratings: AC: 600 V, DC: 300 V • Amp Ratings: 4 Amps • Approvals: UL & CSA Part No. Bussman Ref. No. Littelfuse Ref. No. Amps Qty. 69406 ATQR4 KLD-R-004 4 10 call #80854 Industrial Fuse Puller 1-800-558-2808 / fax Part No. Size Qty. 80855 80854 13/32 to 13/16 diameter 1" to 1-3/4 diameter 1 1 1-800-553-8769 / #80855 www.IMPERIALSUPPLIES.com