Prices as of April 16, 2014. Check Web site for most current prices. Company Information Terminal Blocks Power Supplies and Transformers Power Distribution Blocks Wiring Accessories In this interactive PDF you can: ZIPLink Connection System Up-to-date price list: Multi-wire Connectors www.automationdirect.com/pricelist FREE Technical Support: www.automationdirect.com/support FREE Videos: M12 Junction Blocks Panel Interface Connectors www.automationdirect.com/videos FREE Documentation: www.automationdirect.com/documentation • Use bookmarks to navigate by product category Sensor Cables and Connectors FREE CAD drawings: www.automationdirect.com/cad Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables • Use bookmarks to save, search, print or e-mail the catalog section Wire Management Products Power Supplies DC Converters • Click on part #s to link directly to our online store for current pricing, specs, stocking information and more Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-1 Quality power products... Prices as of April 16, 2014. Check Web site for most current prices. Rhino PSS Series Power Supplies • • • • • • Universal input voltage, 85-264 VAC / 100-375 VDC 24 VDC or 12 VDC outputs, 35 to 100 Watts Dual Output Voltage Model - 24VDC (adjustable), 5VDC (fixed) Rugged aluminum housing Overload, overvoltage and thermal protection UL60950-1 recognized, CE marked Rhino PSB Series Power Supplies • • • • • • • • Universal input voltage, 85-264 VAC / 120-375 VDC single phase or 320-600 VAC 3-phase input 24 VDC or 48 VDC outputs, 15 to 480 Watts Overload, overvoltage and thermal protection (5) 24VDC output, single phase input models for Class 1, Div 2 hazardous locations (2) 48VDC output single phase input models 24VDC (adjustable), 40A (960W) output, 320-600 VAC 3-phase model Redundancy and buffer modules UL508 listed, UL60950-1 recognized, CSA certified, CE marked Rhino PSM Series Power Supplies • • • • Industrial grade Sturdy metal case Low output ripple DIN rail mounting/optional wall mount • Specialty modules for redundancy, power backup and UPS • • • • 12VDC from 78 to 156 watts 24VDC from 90 to 600 watt Overload and overvoltage protection UL508 listed, UL60950-1 recognized, CSA certified, CE marked Rhino PSP Slimline Power Supplies • • • • • • Compact footprint Plastic housing Universal input 85 to 264 VDC/VAC 20 W to 120 W 5 VDC, 20 W, 4 A output 12 VDC from 24 to 120 watts • • • • 24 VDC from 24 to 120 watts DIN rail mounting Overload and overvoltage protection UL508 listed, UL60950-1 recognized, CE marked Book 3 (14.1) ePW-2 Power Supplies 1 - 80 0 - 633 - 0405 ...at great prices Prices as of April 16, 2014. Check Web site for most current prices. Company Information Terminal Blocks Power Distribution Blocks Rhino PSC Series NEC Class 2 Power Supplies • • • • • Wiring Accessories DIN rail mounting 12W to 90W Universal 85 to 264 VAC input voltage and output current limitation. Plastic-housed low-profile UL508 listed, UL1310 recognized for NEC Class 2 compliance and CE marked ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Rhino PS Series Power Supplies • • • • DIN rail mounting Durable metal case 12VDC from 50 to 75 watt 24 VDC from 50 to 600 watt • Overload and overvoltage protection • UL508 listed, UL60950-1 recognized, UL1604 listed for hazardous locations (most models), CE marked Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Rhino PSE Series Encapsulated Power Supplies • Ultra compact, low profile plastic case • Single or dual output models • 5, 12, 15 and 24 VDC • 15W to 60W • Screw terminal blocks • Chassis mount or 35mm DIN rail mount with optional adaptor Wire Management Products • Universal input 85-264 VAC, 47-440 Hz (60 Watt, 47-63 Hz) • Double insulated - no external ground required • UL508 listed, UL60950-1 recognized, CE marked • Short circuit and overload protection • 3-year warranty Transformers and Filters Circuit Protection Tools Enclosures DIN-rail and panel mount DC-to-DC converters PSP series - wide input ranges of 9.5 to 18VDC and 18 to 75VDC for operation with all popular DC supply voltage systems. 5, 12 and 24 VDC adjustable output ranges. FA-DCDC-1 - Isolated ±10VDC, ±5VDC multiple outputs. 12-24VDC input voltage range. Designed to handle many types of configuration applications. Open Frame Power Supplies • Universal inputs: FA-24PS: 100-240 VAC/VDC FA-24PS-90: 95-130 VAC or 190-264 VAC Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s DC Converters Test Equipment DC to DC Converters • DIN rail mounting • 24 VDC • Units available with 1.25 amp or 3.7 amp Power Supplies Power Supplies ePW-3 Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions RHINO PSS Series Panel Mount Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. AutomationDirect’s RHINO PSS series of panel mount power supplies is perfect for applications that require a basic DC voltage power supply. These low cost power supplies offer high performance and reliability without all the additional features of higher cost full-featured power supplies. The RHINO PSS series is available with universal single-phase input and with output voltages of 12 and 24VDC from 35 to 100 Watts. The PSS0524-100 unit provides both a 24VDC and a 5VDC output. The rugged aluminum housing easily screw mounts in three different mounting orientations. These high-quality power supplies include overload, overvoltage and thermal protection, and are UL 60950 recognized, CE marked and RoHS compliant. Features • Universal input voltage, 85–264 VAC / 100–375 VDC • 12VDC, 24VDC or dual 5 and 24VDC, 35 to 100 Watts • Adjustable output voltage • Rugged aluminum housing, screw mounts in three different orientations • Output voltage status LED • Robust fixed-screw terminal strips • Overload, overvoltage and thermal protection • UL 60950 recognized, CE marked and RoHS compliant • Two year warranty PSS Series Input Specifications Part No. Price PSS12-035 $17.75 PSS12-050 $19.75 PSS12-100 $30.00 PSS24-035 $17.75 PSS24-050 $19.75 PSS24-100 $30.00 PSS0524-100 $42.00 Weight Input Frequency Max. Input Current Inrush Current Limitation Input Voltage Range l2t @ 77°F (+25°°C) typ. 0.21 kg [0.46 lb] 0.26 kg [0.57 lb] 0.45 kg [0.99 lb] 0.237 kg [0.52 lb] 85–264 VAC (DC input range 100–375 VDC) <0.75A Max @ 115VAC, <0.5A Max @ 230 VAC <1.1A Max @ 115VAC, <0.7A Max @ 230VAC <2 A Max @ 115VAC, <1.1A Max @ 230VAC 47–63 Hz (0Hz @ DC Input) 0.255 kg [0.56 lb] 0.410 kg [0.90 lb] 0.52 kg [1.15 lb] 85–264 VAC (DC input range 125-375 VDC) Leakage Recommended Current Circuit Breaker <30A @ 115VAC, 60A @ 230VAC 16A “B” Curve <30A @ 115VAC, 60A @ 230VAC <60A @ 115VAC, 130A @ 230VAC <0.75A Max @ 115VAC, <0.5A Max @ 230VAC <30A @ 115VAC, 60A @ 230VAC <1.1A Max @115VAC, <0.7A Max @ 230VAC <30A @ 115VAC, 60A @ 230VAC <2A Max @ 115VAC, <1.1A Max @ 230VAC <50A @ 115VAC, 100A @ 230VAC <1mA 10A “B” Curve 16A “B” Curve PSS Series Output Specifications Output Power Output Current Output Voltage (Vnom) / Adjustment Range 35W 3Amp 50W 4.17 Amp PSS12-100 100W 8.33 Amp PSS24-035 35W 1.46 Amp 50W 2.1 Amp Part No. PSS12-035 PSS12-050 PSS24-050 12VDC / 11–14 VDC 24VDC / 22–28 VDC 6000µF <100 mVpp 8000µF <150 mVpp 4.17 Amp PSS24-100 PSS0524-100 Ripple and Startup with Capacitive Noise Loads (20MHz) V1: 24VDC / 22.8–26.4 VDC V2: 5VDC / Fixed 100W V1: 2.7 Amp V1: <200 mVpp; V2: 7.0 V2: <80 mVpp Amp 4000µF Start-Up Time Hold-Up Time at Nominal Load Rise Time Efficiency (Typ.) (Mains Buffering) >15ms @ 115VAC, >80ms @ 230VAC with >84% (typical) <2500ms @ 100% 35W load (25°C [77°F]) load (25°C [77°F]) >15ms @ 115VAC, and typical line input >83% @ 115VAC & >80ms @ 230VAC with >84% @ 230VAC 50W load (25°C [77°F]) <1000ms @ 100% >15ms @ 115VAC, load (25°C [77°F]) >80ms @ 230VAC with >84% (typical) <30ms @ and typical line input 100W load (25°C [77°F]) 100% load >15ms @ 115VAC, (25°C [77°F]) >85% @ 115VAC & >80ms @ 230VAC with >84% @ 230VAC <2500ms @ 100% 35W load (25°C [77°F]) load (25°C [77°F]) >15ms @ 115VAC, and typical line input >80ms @ 230VAC with 50W load (25°C [77°F]) >86% (typical) >15ms @ 115VAC, >90ms @ 230VAC with <1000ms @ 100% 100W load (25°C [77°F]) load (25°C [77°F]) V1: <30ms, V2: >15ms @ 115VAC, and typical line input <20ms @ >84% @ 115VAC & >80ms @ 230VAC with 100% load >86% @ 230VAC 100W load (25°C [77°F]) (25°C [77°F]) Book 3 (14.1) ePW-4 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSS Series Panel Mount Power Supply Specifications Prices as of April 16, 2014. Check Web site for most current prices. Company Information Terminal Blocks Power Distribution Blocks General Specifications Wiring Accessories Output Line Regulation Output Load Regulation <0.5% typical (@ 85–264 VAC input, 100% load) Overload/Short Circuit Protection >120% rated load current, hiccup mode with auto recovery (PSS0524-100: >150% of total rated output power, hiccup mode, non-latching, auto-recovery) Overvoltage Protection 32VDC max. (PSS0524-100 V1: <32.4 VDC max., V2: 6.75 VDC max.), hiccup mode, non-latching (auto recovery) Case Cover Signals MTBF Noise Cooling Input/Output Terminal Shock Test Vibration Operating Temperature Storage Temperature Humidity at +25 °C [77°F], no condensation Aluminium (Al1100) <1% typical (@ 85–264 VAC input, 0-100% load) Green LED DC OK Sound pressure level (SPL) <40dBA Terminal block 5-Pin rated 300V/20A (PSS0524-100: 7-Pin rated 300V/15A) Wiring Duct 30g half sine, 3 times per direction, 6 directions, per IEC60068-2-27 10 to 150Hz, 5g, 20 min. each axis per IEC60068-2-6 Cable Ties -10°C to +70°C* [14°F to 158°F] Wire -25°C to +85°C [-13°F to 185°F] Flexible Cord <95% RH non-condensing Multi-conductor Flex Cable Data Cables Safety and Agency Approvals EMC / Emissions FCC Title 47, Class B/EN 55022;CISPR22, Class B Immunity EN 61000-4-2,1995; EN 61000-4-3,1998; EN 61000-4-4,1995; IEC61000-4-5,1995; EN 61000-4-6,1996; EN 61000-4-8 or IEC61000-4-12 or IEEE C62.41; EN 61000-3-2,1994 Voltage Dips Galvanic Isolation Conform to EN 61000-4-11 Approvals UR/cUR recognized to UL60950-1 (file no. E198298); CB test certificate and report to IEC60950-1, CE (EMC and Low Voltage directive) RoHS Compliant Yes Input to Output : 3 KVAC, Input to Ground : 1.5 KVAC, Output to Ground : 0.5 KVAC Input Output 0.32-2.1 mm² [AWG 22–14] / 1.3 Nm [11.3 lb-in] 0.32-2.1 mm² [AWG 22–14] / 1.3 Nm [11.3 lb-in] Terminal Block Type Power Supplies DC Converters Transformers and Filters Tools Chassis Mounting Torque Test Equipment Enclosures Enclosure Climate Control Fixed screw terminals 0.32-3.3 mm² [AWG 22–12] / 1.3 Nm [11.3 lb-in] Wire Management Products Circuit Protection Additional Data PSS12-035 PSS12-050 PSS12-100 PSS24-035 PSS24-050 PSS24-100 PSS0524-100 Sensor Cables and Connectors Panel Interface Connectors Convection Wire Size / Torque Multi-wire Connectors M12 Junction Blocks >700,000 hrs. * Operating to 70°C [158°F] possible with a linear derating to half power from 50°C to 70°C [122°F to 158°F] Part No. ZIPLink Connection System Safety: Electrical Components 0.4–0.8 Nm [3.5–7 lb-in] Safety: Protective Wear 0.32-3.3 mm² (AWG 22–12) / 1.3 Nm [11.3 lb-in] Terms and Conditions Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-5 RHINO PSS Series Panel Mount Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Dimensions mm [inches] PSS12-035 Wiring Connection Input N Output Line -V Out - Neutral +V Out + L AC Ground PSS12-050 PSS24-035 PSS24-050 Wiring Connection Input L N Output Line -V Out - Neutral +V Out + AC Ground Drill template available for download at www.AutomationDirect.com Book 3 (14.1) ePW-6 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSS Series Panel Mount Power Supplies Company Information mm [inches] Wiring Accessories Prices as of April 16, 2014. Check Web site for most current prices. Terminal Blocks Power Distribution Blocks Dimensions PSS12-100 PSS24-100 ZIPLink Connection System Multi-wire Connectors Wiring Connection Input Sensor Cables and Connectors Output L Line -V Out - N Neutral +V Out + M12 Junction Blocks AC Ground Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters PSS0524-100 Transformers and Filters Circuit Protection Wiring Connection Input Tools Output L Line N Neutral AC Ground -V2 +V2 5 VDC Out + -V1 +V1 24 VDC Out + Test Equipment 5 VDC Out - Enclosures 24 VDC Out - Enclosure Climate Control Safety: Electrical Components 2 2 1 1 Safety: Protective Wear 1 Terms and Conditions Drill template available for download at www.AutomationDirect.com Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-7 RHINO PSB Series DIN rail Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Single-Phase Input AutomationDirect’s RHINO PSB series of DIN rail power supplies is perfect for applications that require a basic DC voltage power supply. These low cost power supplies offer high performance and reliability without all the additional features of higher cost full-featured power supplies. The following models in the RHINO PSB series are available with universal single-phase input and with output voltages of 12 and 24VDC from 15 to 480 Watts. The rugged plastic and aluminum housings easily install with integral 35mm DIN-rail mounting adapters. These high-quality power supplies include overload, overvoltage and thermal protection, and are UL 508 listed, UL 60950 recognized, CSA certified, CE marked and RoHS compliant. Features • Universal input voltage, 85–264 VAC / 120–375 VDC single phase • 24VDC or 12VDC outputs, 15 to 480 Watts • Adjustable output voltage • Rugged plastic or aluminum housings with integral 35mm DIN-rail mounting adapters • Output voltage status LED • Robust fixed-screw terminal strips with finger-safe covers • Overload, overvoltage and thermal protection • UL 508 listed, UL 60950 recognized, CSA certified, CE marked and RoHS compliant • Three year warranty Input Voltage Inrush Current Limitation l2t @ 77°F [+25°°C] typ. kg PSB12-015-P $21.50 0.175 [0.39 lb] Plastic <0.37 A @ 115VAC, <0.22 A @ 230VAC <30A @ 115 AC, <65A @ 230VAC kg PSB12-030-P $23.50 0.197 [0.43 lb] Plastic <0.7 A @ 115VAC, <0.42 A @ 230VAC <40A @ 115VAC, <80A @ 230VAC 6A “B” Curve $37.25 0.325 kg Aluminum [0.72 lb] <1.35 A @ 115VAC <0.8 A @ 230VAC <50A @ 115VAC, <100A @ 230VAC PSB12-100 $56.00 0.636 kg Aluminum [1.40 lb] <2.5 A @ 115VAC <1.5 A @ 230VAC <100A @ 115VAC, no damage @ 230VAC PSB24-060 $34.75 <1.1 A @ 115VAC <0.7 A @ 230VAC <40A @ 115VAC, <80A @ 230VAC PSB24-060-P $28.00 <1.1 A @ 115VAC <0.7 A @ 230VAC <40A @ 115VAC, <80A @ 230VAC PSB24-120 $63.50 0.54 kg Aluminum [1.19 lb] <1.4 A @ 115VAC <0.8 A @ 230VAC <80A @ 115VAC, <150A @ 230VAC PSB24-240 $115.00 1.04 kg Aluminum [2.29 lb] <2.9 A @ 115VAC <1.5 A @ 230VAC <40A @ 115VAC, <100A @ 230VAC <3.5 mA PSB24-480 $172.00 1.8 kg Aluminum [3.97 lb] <5.7 A @ 115VAC <2.8 A @ 230VAC <50A @ 115VAC, <150A @ 230VAC <1.25 mA 47–63 Hz (0Hz @ DC Input) <2.5 s >22ms @ 115VAC, >110ms @ 230VAC PSB12-060 85–264 VAC (DC input range 0.37 kg Aluminum 120–375 VDC); [0.82 lb] Nominal 100–240 VAC 0.325 kg Plastic [0.72 lb] Hold-Up Time at Nominal Load (Typ.) (Mains Buffering) Turn-on Time Price Weight Housing Max. Input Current Recommended Circuit Breaker Part No. Input Frequency Range Leakage Current PSB Single-Phase Series Input Specifications <1mA <600ms 16A “B” Curve >20ms @ 115VAC, >125ms @ 230VAC <3s >35ms @ 115VAC, >70ms @ 230VAC <1s >20ms @ 115VAC & 230VAC Book 3 (14.1) ePW-8 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSB Series DIN rail Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. PSB Single-Phase Series Output Specifications Startup with Capacitive Derating Loads Output Current Ripple and Noise (20MHz) Output Power Output Voltage (Vnom) / Adjustment Range 2%/11–14VDC PSB12-015-P 12VDC (maximum power <15W) 15W 1.25 A Max 5,000µF 12VDC 2%/11–14VDC PSB12-030-P (maximum power 30W) 30W 2.5 A Max 6,600µF Part No. <100mV PSB12-060 12VDC 2%/11–14VDC (maximum power 60W) PSB12-100 PSB24-060 5A Max 8,000µF 12VDC 2%/11–14VDC (maximum power 100W) 100W 8.33 A Max 10,000µF 24VDC 2%/22–28VDC (maximum power 60W) 2.5 A 60W 60W Max 8,000µF 24VDC 2%/22–28VDC PSB24-060-P (maximum power 60W) PSB24-120 PSB24-240 PSB24-480 60W 2.5 A 24VDC 2%/22–28VDC (maximum power 120W) 120W 5A 24VDC 2%/22–28VDC (maximum power 240W) 240W 10A 24VDC 2%/22–28VDC (maximum power 480W) 480W 20A <50mV / <240mVpp Max 10,000µF Max Power Dissipation Idling / Nominal Load Efficiency Approx. >50°C de-rate power by 2.5%/°C >70°C de-rate power by 4%/°C MTBF 3.2 W 83.5% Min @ 115VAC & 83% Min @ 230VAC 5.6 W 84.5% Min @ 115VAC & 230VAC 10.2 W 85.5% Min @ 115VAC & 230VAC 16.3 W 86% Min @ 115VAC & 87% Min @ 230VAC >50°C de-rate power by 2.5%/°C <0°C de-rate power by 1%/°C 10W >85% typical >50°C de-rate power by 2.5%/°C 22.5 W 42.5 W >50°C de-rate power by 2.5%/°C 72W >300,000 hrs. >300,000 hrs. >86% typical Cable Ties Multi-conductor Flex Cable Data Cables Power Supplies DC Converters PSB60-REM20S, PSB60-REM40S or Oring Diode Aluminium (AI5052) or Plastic (PC) for P Series Transformers and Filters Green LED DC OK <95% RH Circuit Protection 30g half sign, 3 times per direction, 6 directions, per IEC60068-2-27 Tools 10 to 150Hz, 5 g, 90 min. each axis per IEC60068-2-6 2 Test Equipment 3K3 according to EN 60721 Enclosures IEC60204-1 (over voltage category III) EN 50178 / IEC62103 PELV (EN 60204), SELV (EN 60950) UR/cUR recognized to UL 60950-1 (file no. E198298), CSA C22.2 No.60950-1 (file no. 249074), CB scheme to IEC60950-1 UL listed to UL 508 (file no. E197592), CSA to CSA C22.2 No.107.1-01 (file no. 249074) DIN 57100-410 In conformance with EMC directive 2004/108/EC and low voltage directive 2006/95/EC VARISTOR <150% rated load current, hiccup mode with automatic recovery 35VDC max. 4 kVAC / 3 kVAC 1.5 kVAC / 1.5 kVAC 1.5 kVAC / 500VAC IP20 Class I with GND connection Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Wiring Duct Wire Management Products PSB Single-Phase Series Safety and Protection Transient surge voltage protection Overload/Short Circuit Protection Overvoltage Protection Isolation Voltage:: Input/output (type test/routine test) Input/GND (type test/routine test) Output/GND (type test/routine test) Protection Degree Safety Class Sensor Cables and Connectors Flexible Cord PSB Single-Phase Series Certification and Standards Industrial Control Equipment Protection Against Electric Shock CE Multi-wire Connectors Wire >84% typical <1% typical (@ 85–264 VAC input, 0-100% load) Electrical Safety (of information technology equipment) Wiring Accessories Panel Interface Connectors <0.5% typical (@ 85–264 VAC input, 100% load) Electrical Equipment of Machines Electronic Equipment for use in Electrical Power Installations Safety Entry Low Voltage Power Distribution Blocks M12 Junction Blocks PSB Single-Phase Series General Specifications Output Line Regulation Output Load Regulation Parallel Operation Case Cover Signals Humidity at 25°C [77°F], no condensation Shock Vibration (Non-Operating) Pollution Degree Climatic Class Terminal Blocks ZIPLink Connection System >800,000 hrs. >50°C de-rate power by 2.5%/°C >70°C de-rate power by 4%/°C Company Information Power Supplies ePW-9 Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions RHINO PSB Series DIN rail Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Additional Data Wire Size / Torque* Input Output Part No. PSB12-015-P PSB12-030-P PSB12-060 PSB12-100 PSB24-060 PSB24-060-P PSB24-120 PSB24-240 0.32–2.1 mm² [AWG 22–14] / 0.79 Nm [7.0 lb-in] 0.32–2.1 mm² [AWG 22–14] / 0.79 Nm [7.0 lb-in] 0.52–2.1 mm² [AWG 20–14] / 0.78–0.98 Nm [6.94-8.68 lb-in] 0.82–2.1 mm² [AWG 18–14] / 0.78–0.98 Nm [6.94–8.68 lb-in] 0.52–2.1 mm² [AWG 20-14] / 0.78–0.98 Nm [6.94-8.68 lb-in] 0.82–2.1 mm² [AWG 18-14] / 0.78–0.98 Nm [6.94-8.68 lb-in] 0.32–2.1 mm² [AWG 22–14] / 0.78–0.98 Nm [6.94-8.68 lb–in] 0.32–2.1 mm² [AWG 22-14] / 0.78–0.98 Nm [6.94–8.68 lb-in] Ambient Operating Temperature** Storage Temperature -20°C to 50°C [-4°F to 122°F] -25°C to 85°C [-13°F to 185°F] -20°C to 75°C [-4°F to 167°F] -25°C to 85°C [-13°F to 185°F] 1.3–2.1 mm² [AWG 16–14] / 3.5–5.3 mm² [AWG 12–10] / 1.18–1.57 Nm [10.41–13.89 lb-in] 1.18–1.57 Nm [10.41–13.89 lb-in] PSB24-480 *Stripping length 7 mm (0.28 in) or use suitable lug to crimp Dimensions ** See output specifications for temperature derating mm [inches] PSB12-015-P PSB12-030-P Wiring Connection Input Output L Line + Out + N Neutral - Out - AC Ground Book 3 (14.1) ePW-10 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSB Series DIN rail Power Supply Dimensions Prices as of April 16, 2014. Check Web site for most current prices. PSB12-060 PSB24-060 Terminal Blocks Power Distribution Blocks Wiring Accessories ZIPLink Connection System Wiring Connection Input Company Information Output L Line + Out + N Neutral - Out - Multi-wire Connectors Sensor Cables and Connectors AC Ground M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters Transformers and Filters PSB12-100 PSB24-120 Circuit Protection Tools Wiring Connection Input Test Equipment Output L Line + Out + N Neutral - Out - Enclosures Enclosure Climate Control AC Ground Safety: Electrical Components Safety: Protective Wear Terms and Conditions All dimensions in mm [inches] Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-11 RHINO PSB Series DIN rail Power Supply Dimensions Prices as of April 16, 2014. Check Web site for most current prices. Dimensions mm [inches] PSB24-060-P Wiring Connection Input Output L Line + Out + N Neutral - Out - AC Ground PSB24-240 Wiring Connection Input Output L Line + N Neutral + Out + AC Ground - Out - - Out - Out + Book 3 (14.1) ePW-12 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSB Series DIN rail Power Supply Dimensions Prices as of April 16, 2014. Check Web site for most current prices. Dimensions Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories mm [inches] ZIPLink Connection System PSB24-480 Multi-wire Connectors Wiring Connection Input Sensor Cables and Connectors Output L Line + Out + N Neutral + Out + AC Ground - Out - - Out - M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment PSB Power Supply Accessories Enclosures Enclosure Climate Control PSB Series Power Supply Accessories Part No. PSB-CVR Price Description $5.00 Universal replacement terminal cover kit for all RHINO PSB series power supplies. Universal kit includes (9) terminal covers to replace all terminal covers on any PSB power supply model Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-13 RHINO PSB Series DIN rail Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Single-Phase Input AutomationDirect’s RHINO PSB series of DIN rail power supplies is perfect for applications that require a basic DC voltage power supply. These low cost power supplies offer high performance and reliability without all the additional features of higher cost full-featured power supplies. The following models in the RHINO PSB series are available with universal single-phase input and with output voltages of 24VDC or 48VDC from 60 to 480 Watts. They feature removable terminal blocks, high efficiencies, conformal coated circuit boards, and approval for Class 1, Division 2 hazardous locations. The rugged plastic and aluminum housings easily install with integral 35mm DIN rail mounting adapters. These high-quality power supplies include overload, overvoltage and thermal protection, and are UL 508 listed, UL 60950 recognized, CSA certified, CE marked and RoHS compliant. Features • Universal input voltage, 85–264 VAC / 120–375 VDC single-phase • 24VDC or 48VDC outputs, 60 to 480 Watts • Adjustable output voltage • Rugged plastic or aluminum housings with integral 35mm DIN rail mounting adapters • Output voltage status LED • Removable terminal blocks (except PSB24-060S-P and PSB24-480S) with IP20 protection • Conformal coated circuit board for protection against demanding environments • Overload, overvoltage and thermal protection • UL 508 listed, UL 60950 recognized, CSA certified, approved for Class I, Division 2 hazardous locations CE marked and RoHS compliant • Three year warranty 0.33 kg PSB24-060S-P $35.00 [0.73 lb] Plastic 85–264 VAC Nominal 100–240 VAC <1.5A @ 100VAC <40A @ 115VAC, <80A @ 230VAC <20A @ 115VAC, <35A @ 230VAC PSB24-060S $42.00 0.37 kg [0.82 lb] <1.4A @ 115VAC, <0.8A @ 230VAC PSB24-120S $75.00 0.72 kg [1.59 lb] <2.2A @ 115VAC, <1.2A @ 230VAC 1.10 kg [2.43 lb] 47–63 Hz (0Hz @ DC Input) <2.5A @ 115VAC, <1.3A @ 230VAC PSB24-480S 85–264 VAC (DC input range Aluminum 120–375 VDC); 1.37 kg Nominal $192.00 [3.02 lb] 100-240 VAC PSB48-120S $75.00 0.72 kg [1.59 lb] <2.2A @ 115VAC, <1.1A @ 230VAC PSB48-240S 0.97 kg $125.00 [2.14 lb] <2.5A @ 115VAC, <1.3A @ 230VAC PSB24-240S $125.00 Inrush Current Limitation l2t @ 77°F (+25°°C) typ. <5A @ 115VAC, <3A @ 230VAC <35A @ 115VAC, <35A @ 230VAC Hold-Up Time at Nominal Load (Typ.) (Mains Buffering) >20ms @ 115VAC >125ms @ 230VAC (100% load, 25°C) <1mA @ 240VAC <3 sec. <2 sec. >20ms @ 115VAC >115ms @ 230VAC (100% load, 25°C) 16A “B” Curve >20ms @ 115VAC & 230VAC (100% load, 25°C) <3mA @ 240VAC <1mA @ 240VAC Turn-on Time Price Weight Housing Input Max. Frequency Input Range Current Recommended Circuit Breaker Part No. Input Voltage Leakage Current PSB Single-Phase Series Input Specifications <1 sec. >20ms @ 115VAC >125ms @ 230VAC (100% load, 25°C) >20ms @ 115VAC >115ms @ 230VAC (100% load, 25°C) Book 3 (14.1) ePW-14 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSB Series DIN rail Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. PSB24-060S-P 24VDC 2%/22–28 VDC (maximum power 60W) Output Current Part No. Output Voltage (Vnom) / Adjustment Range Output Power PSB Single-Phase Series Output Specifications 60W 2.5 A Ripple and Noise (20 MHz) <50mVpp/<240mV pp @ 25°C PSB24-060S 60W PSB24-120S 24VDC 2%/22–28 VDC (maximum power 120W) 120W 5A PSB24-240S 24VDC 2%/22–28 VDC (maximum power 240W) 240W 10A PSB24-480S 24VDC 2%/22–28 VDC (maximum power 480W) 480W 20A <50mVpp @ 25°C PSB48-120S 48VDC 1%/48–56 VDC (maximum power 120W) 120W 2.5 A <100mVpp @ 25°C PSB48-240S 48VDC 1%/48–56 VDC (maximum power 240W) 240W Startup with Capacitive Derating Loads Max 8,000µF Max. Power Dissipation Idling / Nominal Efficiency Load Approx. >50°C de-rate power by 2.5%/°C >70°C de-rate power by 4%/°C >86.0% @ 115VAC, >87.0% @ 230VAC 9W >50°C de-rate power by 2.5%/°C 14.8 W >89.0% @ 115VAC, >90.0% @ 230VAC >800,000 hrs. >90.0% @ 115VAC & 230VAC >500,000 hrs. 30W Max 10,000µF 5A >800,000 hrs. >90.0% @ 115VAC & >1,000,000 hrs. 230VAC 7.4 W <50mVpp/<150mV pp @ 25°C MTBF <100mVpp @ 85VAC to 265VAC >50°C de-rate power by 2.5%/°C >70°C de-rate power by 5%/°C Max 6,500µF Max 10,000µF >50°C de-rate power by 2.5%/°C 59W 14.8 W >89.0% @ 115VAC & 230VAC >600,000 hrs. 29.6 W >90.0% @ 115VAC & >91.0% @ 230VAC >500,000 hrs. Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Wiring Duct Cable Ties Wire Multi-conductor Flex Cable <0.5% typ. (@ 85–264 VAC input, 100% load) <1% typ. (@ 85–264 VAC input, 0-100% load) Data Cables PSB60-REM20S / PSB60-REM40S or with ORing Diode Wire Management Products Aluminium (AI5052) or Plastic (Polycarbonate) for P Series Green LED DC OK <95% RH (non-condensing) IEC60068-2-27, 30G (300 m/S2) for a duration of 10ms IEC60068-2-6, 10Hz to 500Hz @ 30 m/S2 (3G peak); 60 min per axis for all X, Y, Z direction 2 Power Supplies DC Converters Transformers and Filters 3K3 according to EN 60721 Circuit Protection PSB Single-Phase Series Certification and Standards EN50718 / IEC62103 Electrical Safety UR/cUR recognized to UL60950-1, CSA C22.2 No. 60950-1 (file no. E198298), CB scheme to IEC60950-1, Limited Power Source (LPS) Industrial Control Equipment UL/cUL listed to UL508 and CSA C22.2 No. 107.1-01 (file no. E197592), CSA to CSA C22.2 No. 107.1-01 (file no. 249074) Hazardous Location cCSAus to CSA C22.2 No. 213-M1987, ANSI / ISA 12.12.01:2007 [Class I, Division 2, Group A,B,C,D T4, Ta = -25°C to +75°C (Vertical: > +50°C derating)], (file no. 249074) Class 2 Power Supply UR/cUR Class 2 power supply recognized to UL1310 and CSA C22.2 No. 223 (file no. E198298) (PSB24-060S-P only) CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear PSB Single-Phase Series Safety and Protection Terms and Conditions VARISTOR <32V 10%, SELV Output, hiccup mode, non-latching (auto-recovery) >120% & 150% of rated load current, hiccup mode, non-latching (auto-recovery) 4 kVAC / 3 kVAC 1.5 kVAC / 1.5 kVAC 1.5 kVAC / 500 VAC IP20 Class I with GND connection Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Distribution Blocks Flexible Cord Electrical Equipment of Machines Transient surge voltage protection Overvoltage Overload / Overcurrent Isolation Voltage:: Input/output (type test/routine test) Input/GND (type test/routine test) Output/GND (type test/routine test) Protection Degree Safety Class Terminal Blocks Panel Interface Connectors PSB Single-Phase Series General Specifications Output Line Regulation Output Load Regulation Parallel Operation Case Cover Signals Humidity at 25°C [77°F], no condensation Shock Vibration (Non-Operating) Pollution Degree Climatic Class Company Information Power Supplies ePW-15 RHINO PSB Series DIN rail Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Additional Data Wire Size / Torque* Part No. Terminal Block Type Ambient Operating Temperature** Fixed screw terminals -25°C to 80°C [-13°F to 176°F] Removable screw terminals -25°C to 80°C [-13°F to 176°F] Input Output PSB24-060S-P 0.32–5.3 mm² [AWG 22–10] / 0.45 Nm [3.96 lb-in] 0.32–5.3 mm² [AWG 22–10] / 0.45 Nm [3.96 lb-in] PSB24-060S 0.32–3.3 mm² [AWG 22–12] / 0.46 Nm [4.05 lb-in] 0.32–3.3 mm² [AWG 22–12] / 0.46 Nm [4.05 lb-in] PSB24-120S 0.52–3.3 mm² [AWG 20–12] / 0.46 Nm [4.05 lb-in] 0.52–3.3 mm² [AWG 20–12] / 0.46 Nm [4.05 lb-in] PSB24-240S 1.3–2.1 mm² [AWG 16–14] / 0.46 Nm [4.05 lb-in] 1.3–2.1 mm² [AWG 16–14] / 0.46 Nm [4.05 lb-in] PSB24-480S 0.82–5.3 mm² [AWG 18–10] / 0.45 Nm [3.91 lb-in] 3.5–5.3 mm² [AWG 12–10] / 0.45 Nm [3.91 lb-in] Fixed screw terminals -25°C to 75°C [-13°F to 167°F] 0.52–3.3 mm² [AWG 20–12] / 0.46 Nm [4.05 lb in] 0.52–3.3 mm² [AWG 20–12] / 0.46 Nm [4.05lb in] Removable screw terminals -25°C to +80°C [-13°F to 176°F] Storage Temperature -25°C to 85°C [-13°F to 185°F] PSB48-120S PSB48-240S *Stripping length 7 mm (0.28 in) or use suitable lug to crimp ** See output specifications for temperature derating Dimensions mm [inches] PSB24-060S-P Wiring Connection Input Output L Line + Out + N Neutral - Out - AC Ground Book 3 (14.1) ePW-16 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSB Series DIN rail Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Company Information Terminal Blocks Power Distribution Blocks Dimensions mm [inches] Wiring Accessories PSB24-060S ZIPLink Connection System Multi-wire Connectors Wiring Connection Input Output L Line + Out + N Neutral - Out - Sensor Cables and Connectors M12 Junction Blocks AC Ground Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters Transformers and Filters PSB24-120S Circuit Protection Tools Wiring Connection Input L N Test Equipment Output Line + Out + Neutral + Out + AC Ground - Out - - Out - Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-17 RHINO PSB Series DIN rail Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Dimensions mm [inches] PSB24-240S Wiring Connection Input Output L Line + Out + N Neutral + Out + AC Ground - Out - - Out - PSB24-480S Wiring Connection Input L N Output Line + Out + Neutral + Out + AC Ground - Out - - Out - Book 3 (14.1) ePW-18 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSB Series DIN rail Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Company Information Terminal Blocks Power Distribution Blocks Dimensions mm [inches] Wiring Accessories PSB48-120S ZIPLink Connection System Wiring Connection Input Multi-wire Connectors Output L Line + Out + N Neutral + Out + AC Ground - Out - - Out - Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies PSB48-240S DC Converters Transformers and Filters Wiring Connection Input L N Output Line + Out + Neutral + Out + AC Ground - Out - - Out - Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-19 RHINO PSB Series DIN rail Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Three-Phase Input AutomationDirect’s RHINO PSB series of DIN rail three-phase input power supplies is perfect for applications that require a basic DC voltage power supply. These low cost power supplies offer high performance and reliability without all the additional features of higher cost full-featured power supplies. The three-phase input eliminates the need for a separate step down transformer and the output of 24VDC is available from 60 to 960 Watts. The rugged aluminum housings easily install with integral 35mm DIN rail mounting adapters. These high-quality power supplies include overload, overvoltage and thermal protection, and are UL 508 listed, UL 60950 recognized, CSA certified, CE marked and RoHS compliant. Units are covered by a 3-year warranty. PSB24-060S-3 $59.00 0.66 kg [1.46 lb] PSB24-120S-3 $76.00 <30A @ 400VAC & 500VAC @ 25°C (With <1.3 A / Phase @ 3Ph AC source capability up to 3KVA) 400VAC and <55A @ 400VAC & <0.25 A / Phase @ 500VAC @ 25°C (With 500VAC 3Ph AC source capability up to 18KVA) <30A @ 400VAC & 500VAC @ 25°C (With <0.5 A / Phase @ 3Ph AC source capability up to 3KVA) 400VAC and <60A @ 400VAC & <0.4 A / Phase @ 500VAC @ 25°C (With 500VAC 3Ph AC source capability up to 18KVA) >20ms @ 3 x 400VAC, >40ms @ 3 x 500VAC <3.5 mA PSB24-240S-3 Hold-Up Time at Nominal Load (Typ.) (Mains Buffering) Turn-on Time Input Voltage Inrush Current Limitation l2t @ 77°F (+25°°C) typ. Recommended Circuit Breaker Housing Max. Input Current Leakage Current Price Input Frequency Range Part No. Weight PSB Three-Phase Series Input Specifications <40A @ 400VAC & 500VAC @ 25°C (With <0.75 A / Phase @ 3Ph AC source capability up to 3KVA) 400VAC and 0.89 kg $127.00 Aluminum 320 to 600VAC 47–63 Hz [1.96 lb] <60A @ 400VAC & <0.65 A / Phase @ 500VAC @ 25°C (With 500VAC 3Ph AC source capability up to 18KVA) 1.35 kg PSB24-480S-3 $180.00 [2.98 lb] <50A @ 400VAC & 500VAC @ 25°C (With <0.95 A / Phase @ 3Ph AC source capability up to 3KVA) 400VAC and <70A @ 400VAC & <0.75 A / Phase @ 500VAC @ 25°C (With 500VAC 3Ph AC source capability up to 18KVA) 2.6 kg PSB24-960S-3 $265.00 [5.73 lb] 1.7 A Max / Phase <50A @ 500VAC @ 25°C 3 x circuit breakers 16A “B” Curve <3mA @ 575VAC <1000ms @ 100% load (25°C) and typical line input >20ms @ 3 x 400VAC & 3 x 500VAC Book 3 (14.1) ePW-20 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSB Series DIN rail Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Output Power Output Current Part No. Ripple and Noise (20 MHz) 24–28 VDC (maximum power 60W) 60W 2.5 A (60W Max) 24–28 VDC (maximum power 120W) 120W PSB24-240S-3 24–28 VDC (maximum power 240W) 240W PSB24-480S-3 24–28 VDC (maximum power 480W) 480W 20A (480W Max) PSB24-960S-3 24–28 VDC (maximum power 960W) 960W 40A (960W Max) PSB24-060S-3 PSB24-120S-3 Startup with Capacitive Derating Loads Max Power Dissipation Idling Efficiency / Nominal Load Approx. 9.8 W MTBF 10A (240W Max) <150mVpp at 320VAC to 600VAC input Max 10,000µF >50°C de-rate power by 2.5%/°C >70°C de-rate power by 5%/°C 16.5 W >86% @ 3 x 400VAC & 3 x 500VAC >87% @ 3 x 400VAC, >86% @ 3 x 500VAC >300,000 hrs 53W >50°C de-rate power by 2.5%/°C Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks 26.7 W >90% @ 3 x 400VAC & 3 x 500VAC <240mVpp at 320VAC to 575VAC input Wiring Accessories ZIPLink Connection System >500,000 hrs 5A (120W Max) Terminal Blocks Power Distribution Blocks PSB Three-Phase Series Output Specifications Output Voltage (Vnom) / Adjustment Range Company Information Panel Interface Connectors Wiring Duct Cable Ties 94W Min 91% typ Wire Flexible Cord Multi-conductor Flex Cable PSB Three-Phase Series General Specifications Output Line Regulation Output Load Regulation Parallel Operation Case Cover Signals Humidity at +25°C [77°F], no condensation Shock Vibration (Non-operating) Pollution Degree Climatic Class <0.5% typ. (@ 320 to 600VAC input, 100% load) Data Cables <1% typical (with rated input, 0 to 100% load) Wire Management Products PSB60-REM20S* / PSB60-REM40S or with ORing Diode Aluminium (AI5052) Green LED DC OK Power Supplies <95% RH (non-condensing) DC Converters IEC 60068-2-27 IEC 60068-2-6 Transformers and Filters 2 3K3 according to EN 60721 Circuit Protection * Does not apply to the PSB24-960S-3 Tools PSB Three-Phase Series Certification and Standards EMC / Emissions FCC Title 47, Class B / EN55022, CISPR22, CISPR11, Class B Immunity EN61000-4-2, 1995; EN61000-4-4, 1995; EN61000-4-5, 1995; IEC61000-4-12 or IEEE C62.41; EN61000-4-3, 1998; EN61000-4-8; EN61000-4-6, 1996 Approvals UL/cUL listed to UL508 and CSA C22.2 No. 107.1-01 (file no. E197592), CSA to CSA C22.2 No. 107.1-01 (file no. 249074) UR/cUR recognized to UL60950-1 and CSA C22.2 No. 60950-1 (file no. E198298) CE (EMC and Low Voltage directive) Voltage Dips EN61000-4-11 Safety: Electrical Components Safety: Protective Wear Terms and Conditions Varistor > 150% of rated load current, auto recovery (hiccup mode) <32V, 10%, SELV output, non-latching (autorecovery) 4 KVac 1.5 KVac 1.5 KVac IP20 Class I with GND connection Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Enclosures Enclosure Climate Control PSB Three-Phase Series Safety and Protection Transient Surge Voltage Protection Overload/Short Circuit Protection Overvoltage Protection Isolation Voltage: Input/output Input/GND Output/GND Protection Degree Safety Class Test Equipment Power Supplies ePW-21 RHINO PSB Series DIN rail Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Additional Data Wire Size / Torque* Part No. PSB24-060S-3 PSB24-120S-3 PSB24-240S-3 Input Output 0.82–3.3 mm² [AWG 18–12] / 0.92 Nm [8.1 lb-in] 0.82–3.3 mm² [AWG 18–12] / 0.61 Nm [5.4 lb-in] 0.82–3.3 mm² [AWG 18–12] / 0.92 Nm [8.1 lb-in] 1.3–3.3 mm² [AWG 16–12] / 0.61 Nm (5.4 lb-in) 0.82–8.4 mm² [AWG 18–8] / 0.92 Nm [8.1 lb-in] 3.3–5.3 mm² [AWG 12–10] / 0.92 Nm [8.1 lb-in] Terminal Block Type Ambient Operating Storage Temperature Temperature** -25°C to +80°C [-13°F to 176°F] Fixed screw terminals -25°C to +85°C [-13°F to 185°F] PSB24-480S-3 PSB24-960S-3 -25°C to +65°C [-13°F to 149°F] *Stripping length 7 mm (0.28 in) or use suitable lug to crimp ** See output specifications for temperature derating Dimensions mm [inches] PSB24-060S-3 PSB24-120S-3 Wiring Connection Input Output L1 Line 1 + Out + L2 Line 2 + Out + Line 3 - Out - AC Ground - Out - L3 Book 3 (14.1) ePW-22 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSB Series DIN rail Power Supply Dimensions Prices as of April 16, 2014. Check Web site for most current prices. Dimensions Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories mm [inches] ZIPLink Connection System PSB24-240S-3 Multi-wire Connectors Wiring Connection Input Output L1 Line 1 + Out + L2 Line 2 + Out + L3 Line 3 - Out - AC Ground - Out - Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products PSB24-480S-3 Power Supplies DC Converters Wiring Connection Input Transformers and Filters Output L1 Line 1 + Out + L2 Line 2 + Out + L3 Line 3 - Out - AC Ground - Out - Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-23 RHINO PSB Series DIN rail Power Supply Dimensions Prices as of April 16, 2014. Check Web site for most current prices. Dimensions mm [inches] PSB24-960S-3 Wiring Connection Input Output L1 Line 1 + Out + L2 Line 2 + Out + L3 Line 3 - Out - AC Ground - Out - Book 3 (14.1) ePW-24 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSB Power Supply Accessories Prices as of April 16, 2014. Check Web site for most current prices. Company Information Redundancy Module Terminal Blocks Power Distribution Blocks The RHINO PSB60-REM series redundancy modules are used with two RHINO PSB series power supplies in parallel to create redundancy to help prevent costly downtime due to power supply failure. The redundancy module decouples the outputs of the two connected power supplies so that in case of failure, one power supply cannot overload the other. The modules can handle power supply voltages from 22 to 60VDC and provides alarm relay contacts for remote monitoring. Wiring Accessories ZIPLink Connection System Multi-wire Connectors Features Sensor Cables and Connectors • Provides redundancy and parallel operation of two RHINO PSB power supplies • Wide input and output range 22–60 VDC • Input voltage OK LED and relay alarm indication • Corrosion resistant aluminum housing • Approved for use in Class I, Division 2 hazardous locations • Three year warranty M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Redundancy Modules Part No. PSB60-REM20S Price Weight Wire PSB60-REM40S $35.00 $43.00 0.375 kg [0.83 lb] 0.515 kg [1.14 lb] Flexible Cord Multi-conductor Flex Cable Redundancy Module Input Specifications Nominal Input Voltage 24–48 VDC Voltage Range 22–60 VDC Nominal Current 20A max Wire Management Products 40A max Power Supplies 24V system: both Vin1 & Vin2 >18V 5% or < 30V max. relay contacts 48V system: both Vin1 & Vin2 >36V 5% or <60V max. relay contacts Input Voltage Alarm/Relay Contacts Input Voltage LED Operation Data Cables The LED will turn on when the Vin1 & Vin2 >18V 5% (for 24V systems) or >36V 5% (for 48V system) and not more than 30V (for 24V systems) or not more than 60V (for 48V systems), the relay contacts will be closed. If Vin1 & Vin2 is under or over this range, the LED will turn off Redundancy Module Output Specifications Nominal Output Voltage UN / Tolerance Tools 20A max Derating above +50°C Test Equipment 40A max Enclosures >50°C [2.5% / K] Short Circuit / Over Load Limit <25A Efficiency <50A Enclosure Climate Control >97% typical Note: The overload condition must be controlled by the power supply units in parallel; The limit of input current should not be more than 25A (for 20A module) or not more than 50A (for 40A module) Safety: Electrical Components Safety: Protective Wear Redundancy Module Certification / Standards Electrical Equipment of Machines IEC60204-1 (over voltage category III) Terms and Conditions Electrical Safety (IT equipment) UR/cUR recognized to UL60950-1 (file no. E198298), CB test certificate and report to IEC60950-1 and CE Industrial Control Equipment UL/cUL recognized to UL508 and CSA C22.2 No. 107.1-01 (file no. E197592) Hazardous Location cCSAus to CSA C22.2 No. 213-M1987, ANSI / ISA 12.12.01:2007 [Class I, Division 2, Group A,B,C,D T4, Ta = -40°C to +80°C (> +50°C derating)], (file no. 249074) Electronic Equipment For Use in Electircal Power Installations EN50178 / IEC62103 Safety Entry Low Voltage PELV (EN60204), SELV (EN60950) RoHS Compliant Protection Against Electric Shock Yes, RoHS directive, WEEE directive DIN 57100-410 Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Transformers and Filters Circuit Protection Vin-0.65V (Typ.) Nominal Current DC Converters Power Supplies ePW-25 RHINO PSB Power Supply Accessories Prices as of April 16, 2014. Check Web site for most current prices. Redundancy Module General Specifications Isolation Voltage: Input / PE Output / PE 1.5 KVAC / 1.5 KVAC 1.5 KVAC / 1.5 KVAC Degree of Protection IP20 Class of Protection Class II with PE connection MTBF >800,000 hrs. per BELL CORE STD or IEC61709 Type of Housing Aluminum (AL1100F) Redundancy Module Environmental Specifications Humidity at +25°C, no condensation <95% RH Vibraton 10Hz to 500Hz @ 30 m/S2 (3G peak); displacement of 0.35 mm; 60 min per axis for all X, Y, Z direction. Refer to IEC 60068-2-6. Note: all figures quoted are amplitudes (peak values) Shock (in all directions) IEC60068-2-27, 30G (300m/s2) for duration 18 ms 1 Shock in 2 directions tested with fixture with EUT mounted on DIN rail in vertical and horizontal position Pollution Degree 2 according to EN50178 Climatic Class 3K3 according to EN60721 Additional Data Wire Size / Torque* Input Output Part No. PSB60-REM20S PSB60-REM40S 3.3–5.3 mm² [AWG 12–10] / 0.72 Nm [6.3 lb-in] 3.3–5.3 mm² [AWG 12–10] / 0.72 Nm [6.3 lb-in] Terminal Block Type Fixed screw terminals Ambient Operating Storage Temperature Temperature** -25°C to +80°C [-13°F to 176°F] -25°C to +85°C [-13°F to 185°F] *Stripping length 7 mm (0.28 in) or use suitable lug to crimp ** See output specifications for temperature derating Dimensions mm [inches] PSB60-REM20S PSB60-REM40S Wiring Connection Input Output Vin1 Line 1 Vout+ Vin2 Line 2 Vout+ Output + Output + Com Common OK Alarm Relay OK Alarm Relay Book 3 (14.1) ePW-26 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSB Power Supply Accessories Prices as of April 16, 2014. Check Web site for most current prices. Company Information Terminal Blocks Redundancy Module Wiring Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors COM COM LOAD Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct + Vout Cable Ties OK + Wire Output DC 20A MAX Flexible Cord DC OK signal Multi-conductor Flex Cable Data Cables L(L1) N(L2) Wire Management Products PE Parallel Operation Power Supplies When 2 power supplies are connected in parallel, they can share the load if the following steps are taken. DC Converters Transformers and Filters Step 1: Measure the output voltages at no load from Vin1 to Com of power supply 1 and Vin2 to Com of power supply 2. If the voltages are not the same, follow Step 2. If they are the same, skip to Step 3. Circuit Protection Tools Test Equipment Step 2: Adjust the output voltages, with the help of the adjustment pot on the power supply front panel marked as ADJUST, to the same level. For example, if power supply 1 is measuring 24.15 VDC and power supply 2 is measuring 24.25 VDC, adjust the output voltage of one to be the same as the other. Enclosures Enclosure Climate Control Step 3: Connect the power supply to the end system load and measure the output voltages from Vin1 to Com of power supply 1 and Vin2 to Com of power supply 2. Ensure that the output voltages are the same even after the 2 power supplies are connected to load. If not, adjust them with the adjustment pot available on the front panel. A tolerance of 25mV would be acceptable. Safety: Electrical Components Safety: Protective Wear Terms and Conditions Note: 1) If the output voltage of any power supply is higher, it will take the initial load and share the maximum load. 2) If the output voltages are the same, then an equal load current sharing between the 2 power supplies can be achieved. Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-27 RHINO PSB Power Supply Accessories Prices as of April 16, 2014. Check Web site for most current prices. Buffer Module The RHINO PSB24-BFM20S buffer module is a cost effective alternative to battery-based backup systems. Utilizing electrolytic capacitors the buffer module is maintenance free and will maintain the output voltage of a 24VDC power supply system for 250 msec minimum with a 20A load and 5 sec minimum with a 1A load. A switch is provided to select the voltage level to start buffering. An inhibit input is available for remote shutdown as well as output signals for remote stand-by and buffering mode indication. The module is housed in a corrosion-resistant aluminum chassis with IP20 terminals and confromal coated circuit board for protection against demanding environments. Features • Corrosion-resistant aluminum housing • Long minimum buffering time of 250ms @ 24V/20A • Units can be connected in parallel to increase buffering time • Less than 30 second charging time • Approved for use in Class I Division 2 hazardous locations • IP20 wiring terminals • Overvoltage / Overcurrent / Short Circuit protections • Three year warranty Buffer Module Part No. PSB24-BFM20S Price $149.00 Weight 0.76 kg [1.68 lb] Buffer Module Input Specifications Nominal Input Voltage Voltage Range 24VDC 22.8 to 28.8 VDC (35VDC Max) Input Current Charging mode: < 0.6 A; Discharging mode: 20A Max Input Power 2.5 W average Maximum Signal Input (Inhibit) Max Inrush Current Charging Time 35V / 10mA <20A <30sec Buffer Module Output Specifications Nominal Output Voltage Adjustment Range Of The Voltage 24VDC typ. (depends on Vin) 22 to 28VDC Switch = “Fix 22V” - Buffering starts if terminal voltage falls below 22V Factory Setting, Switch = “Vin - 1V” - Buffering starts if terminal voltage is decreased by >1V Maximum Output Voltage 35VDC Output Current 20A max Buffering Time 250ms Min @ 24V / 20A Load, 5sec Min @ 24V / 1A Load (Refer to Fig. 1) Maximum Signal Output 35V / 10mA Inhibit Signal (I) - “Low” = shuts down buffer module Ready Signal (R) - “High” = buffer module is fully charged or in standby mode Buffering Signal (B) - “High” = Buffer module is discharging or in buffering mode Supply Voltage (+Vs) - Common +Vs, 35V Max Signals Noise and Ripple (20MHz) Parallel Connection <200mVpp @ 25°C [77°F] during buffering mode Yes (requires PSB60-REM redundancy module) Series Connection No Protective Device Transient voltage suppressor (TVS) for signals Book 3 (14.1) ePW-28 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSB Power Supply Accessories Prices as of April 16, 2014. Check Web site for most current prices. Figure F1ig. 1 Company Information Terminal Blocks Power Distribution Blocks B uffe ring T ime (Typic a l Va lue s a t “ V in-1V” Mode) 9 Wiring Accessories 8 Buffering Time (sec) 7 ZIPLink Connection System 6 5 Multi-wire Connectors 4 3 Sensor Cables and Connectors 2 1 M12 Junction Blocks 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Current (A) Panel Interface Connectors Buffer Module Mechanical Specifications Case Cover Wiring Duct Aluminum LED Indicators Green LED Off - Unit is discharged or Vin <22VDC Green LED On - Unit is fully charged Cooling System Convection Terminal Wire Cable Ties Wire Flexible Cord Input / Output - M3 x 2 pins (Rated 300V / 30A) Signal - M3 x 5 pins (Rated 300V / 30A) Multi-conductor Flex Cable Input / Output - AWG 12–10 [0.08–0.10 in]; Torque: 0.72 Nm [6.3 lb-in] Signal - AWG 24–10 [0.02–0.10 in]; Torque: 0.72 Nm [6.3 lb-in] Data Cables Operating Temperature -25°C to +75°C [-13°F to +167°F] Wire Management Products Storage Temperature -25°C to +85°C [-13°F to +185°F] Power Supplies >70°C [158°F] de-rate power by 5% / °C DC Converters Operating Humidity <95% RH (Non-Condensing) Operating Altitude 2,500 Meters Transformers and Filters Buffer Module Environmental Specifications Power De-rating Shock Test (Non-Operating) IEC60068-2-27, 30G (300m/S2) for a duration of 18ms Vibration (Non-Operating) IEC60068-2-6, 10 Hz to 500 Hz @ 30m/S2 (3G peak); 60min per axis for all X, Y, Z direction Pollution Degree Circuit Protection Tools Test Equipment 2 Enclosures Buffer Module Protection Specifications Overload / Overcurrent No damage Safety: Protective Wear >3.5mm (eg. screws, small parts) Reverse Polarity Protection Yes Degree of Protection IP20 Protection Against Shock Safety: Electrical Components 30A Max Short Circuit Penetration Protection Enclosure Climate Control 32V 10% Overvoltage Terms and Conditions Class I with GND connection Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-29 RHINO PSB Power Supply Accessories Prices as of April 16, 2014. Check Web site for most current prices. Buffer Module Reliability Specifications MTBF (at Vin-1V Mode) >2,800,000 hrs. as per Telcordia SR-332 at Standby Mode (Buffer Module in Ready State) Expected Capacitor Life 10 years (Standby mode @ 40°C) Buffer Module Safety Standards / Directives Electronic Equipment in Power Installations EN50718 / IEC62103 Electrical Safety (Information Technology Equipment) UR/cUR recognized to UL60950-1 and CSA C22.2 No. 60950-1 (file no. E198298), CB scheme to IEC60950-1 Industrial Control Equipment UL/cUL listed to UL508 and CSA C22.2 No. 107.1-01 (file no. E197592) CSA to CSA C22.2 No. 107.1-01 (file no. 249074) Hazardous Location cCSAus to CSA C22.2 No. 213-M1987, ANSI / ISA 12.12.01:2007 [Class I, Division 2, Group A,B,C,D T4, Ta = -25°C to +75°C (> +70°C derating)], (file no. 249074) CE in conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC Materials and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input & Output to Ground - 1.5 KVAC Signal to Ground - 1.5 KVAC Buffer Module EMC Specifications EMC / Emissions CISPR22, EN55022, EN55011 Component Power Supply for General Use EN61204-3 Immunity EN55024, EN61000-6-2 Electrostatic Discharge EN61000-4-2 Radiated Field EN61000-4-3 Fast Transient / Burst EN61000-4-4 Surge IEC61000-4-5 Conducted EN61000-4-6 Power Frequency Magnetic Fields EN61000-4-8 Voltage Dips EN61000-4-11 Low Energy Pulse Test (Ring Wave) EN61000-4-12 Note: Product intended to be used as Apparatus with AC-DC Power Supply, EMC compliance to be verified in correspondence to the connected units. Dimensions mm [inches] PSB24-BFM20S Wiring Connection Input Output + DC+ R Ready - DC+ B Buffering I Inhibit +Vs + Voltage Supply Ground Book 3 (14.1) ePW-30 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSB Power Supply Accessories Prices as of April 16, 2014. Check Web site for most current prices. Company Information Terminal Blocks Power Distribution Blocks Buffering, Ready and Inhibit Signal Buffering Output Signal (B) “High” = PSB24-BFM20S is discharging or in Buffering Mode Ready Output Signal (R) Wiring Accessories “High” = PSB-BFM20S is fully charged or in Standby Mode Inhibit Input Signal (I) ZIPLink Connection System “Low” = Shuts down Buffer Module Signal Voltage +VS: 10–35 VDC Maximum Signal Current 10mA Isolation (Signal to Power) Multi-wire Connectors 1.5 KVAC Sensor Cables and Connectors I/O (input/output) Example M12 Junction Blocks +V S Inhibit Input Panel Interface Connectors Wiring Duct I Cable Ties Ready Output Wire Flexible Cord R 10mA Max Multi-conductor Flex Cable Buffering Output Data Cables Wire Management Products B 10mA Max Power Supplies +V S : 10-35VDC DC Converters Buffer Module Operations Transformers and Filters Circuit Protection Hold-up Time Tools t Vac Test Equipment Enclosures t Buffer Module Enclosure Climate Control V buff V out Safety: Electrical Components t High Low Low Ready Safety: Protective Wear t Terms and Conditions High Low t Buffering t Inhibit 1 Hz 10 Hz t LED Charging Mode Standby Mode Buffer Mode Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-31 RHINO PSB Power Supply Accessories Prices as of April 16, 2014. Check Web site for most current prices. Buffer Module Wiring General connection / wiring diagram Power Supply L N GND L N GND Buffer Module I + - + - Buffer Module Bu Buffered LLoad I R B V+ R B V+ Inhibit + - Ready Relay, lamp or signal - Buffering Relay, lamp or signal + + - General signals wiring Range Select Switch Optional Parallelling of buffer units + + - - + - Power Supply L N GND L N GND + - Buffer Module I + - Buffer Module I R B V+ Buffered Load R B V+ Optional Decoupling of buffered branches + + - + - Power Redundancy Supply Module L N GND L N PE L N Optional GND + - + + - + + - - Unbuffered Load + - I R B V+ Out + + OK Buffer Module I + - Buffered Load R B V+ Optional Book 3 (14.1) ePW-32 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSM Series Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Versatile switching power supplies are DIN-rail mountable Remote ON/OFF For parallel operation or battery charge mode selectable by jumper Control output for true N+1 redundancy or battery operation AUTOMATIONDIRECT offers the most practical industrial control power supplies available. The RHINO PSM series power supplies are industrial grade switching DC Multiple output terminals output supplies with a sturdy steel case to for easy wiring withstand harsh environments. Autoselect inputs for 115 VAC or 230 VAC and international agency approvals make the Dual color status RHINO PSM series suitable for worldwide indicator LED use. RHINO PSM power supplies are available in 12 or 24 VDC output, with adjustable output voltages, and feature Adjustable output voltage low output ripple along with overload and overtemperature protection. The seven models offer power ratings from 78W to DC-OK monitoring via 600W, and up to 25A output current. Features • Industrial grade design • Sturdy metal case to withstand harsh industrial environments • Model PSM24-090S-N meets NEC Class 2 • Universal 100/230 VAC input voltage • Adjustable output voltage • Low output ripple • Short-circuit, overvoltage and overtemperature protection • Power Good signal • Remote ON/OFF • Optional wall mounting • Specialty modules for redundancy, power backup and UPS • Terminal connectors included • 3-year product warranty Rugged, ultracompact metal case, shock and vibration to IEC 68-2 Industrial approvals: CSA C22.2-60950 IEC/EN 60950 UL508 UL60950 Convection cooling, no internal fan, thermal overload protection relay contact and PNP output Full CE compliance including EN61000-3-2 Universal input voltage for worldwide use Self-locking DIN-rail fixing latch Part Numbering System PSM 24 090S-N NEC Class 2 Screw Terminal Connector Output Watts Output Volts Series Name : PSM = metal case RHINO PSM Industrial Power Supplies Part Number PSM12-078S PSM24-090S PSM24-090S-N PSM12-156S PSM24-180S PSM24-360S PSM24-600S *Output Voltage (Vnom) **Output Current (Imax) ***Output Power (Pmax) 12 VDC 6.5 A 78 W 24 VDC 3.75 A 90 W 24 VDC 3.75 A 90 W 12 VDC 13.0 A 156 W 24 VDC 7.5 A 180 W 24 VDC 15.0 A 360 W 24 VDC 25.0 A 600 W *12V models adjustable from 12 to14 VDC. 24V models adjustable from 24 - 28 VDC **Maximum current at nominal output voltage ***Up to an operating temperature of +40°C Book 3 (14.1) ePW-34 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSM Series Power Supplies Specifications Prices as of April 16, 2014. Check Web site for most current prices. Input Specifications Part Number Input Current Inrush Current max Operating Input Holdup Voltage Frequency (Typical) at full load (<2ms) @ +25°C Time min/max Range 115 VAC 230 VAC 115 VAC 230 VAC Input Voltage Range PSM12-078S 100 - 240 VAC PSM24-090S Universal Input PSM24-090S-N 85 - 264 VAC PSM12-156S PSM24-180S PSM24-360S PSM24-600S 47-63 Hz 100 - 120 VAC/ 85 - 132 VAC/ 220 - 230 VAC 187 - 264 VAC Autoselect Efficiency Circuit Breaker (Typical) or Fuse @ 115VAC (slo-blo) 2.0 A 1.0 A 2.1 A 1.0 A 2.1 A 1.0 A 2.5 A 1.4 A 2.8 A 1.5 A 5.0 A 2.5 A <16 A <25 A 87% 10.0 A to 16.0 A 10.0 A 5.0 A <25 A <30 A 89% 16.0 A to 25.0 A 82% <12 A <13 A <20 A <25 A 85% 20 ms min. (full load 115/230 VAC) 85% 6.0 A to 16.0 A 88% PSM12-078S PSM24-090S PSM24-090S-N PSM12-156S PSM24-180S PSM24-360S PSM24-600S $132.00 $99.00 $135.00 $158.00 Output Output Output Output Output Voltage Adj. Current Power Overvoltage Voltage Range Active Output (Max.) (Max.) Protection Trigger Threshold Signal 12 VDC 24 VDC 12 VDC 12 - 14 VDC 24 - 28 VDC 12 - 14 VDC $152.00 $229.00 24 VDC 24 - 28 VDC $341.00 6.5 A 78 watts 20 V 3.75 A 90 watts 35 V 3.75 A 90 watts 35 V 13.0 A 156 watts 20 V 7.5 A 180 watts 35 V 15.0 A 360 watts 35 V 25.0 A 600 watts 35 V Power Distribution Blocks Wiring Accessories ZIPLink Connection System Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Power - Good Signal Price Terminal Blocks Multi-wire Connectors 85% Output Specifications Part Number Company Information MTBF Relay Output (IEC 61709 @ 25°C) Wiring Duct Cable Ties 9 - 11 V 11 V ± 1 V/20 mA max. Wire 18 - 22 V 22 V ± 2 V/10 mA max Flexible Cord 9 - 11 V DC OK = contact closed 11 V ± 1 V/40 mA max. (rated:30 VDC 1.0A) 18 - 22 V 22 V ± 2 V/20 mA max 350,000 hours Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies General Specifications Specification Description DC Converters Temperature Operating (ambient): -25°C to + 70°C max (-13°F to 158°F). Above +40°C(104°F) load derating Storage (non-operating): -25°C to + 85°C max (-13°F to 185°F). Temperature drift: 0.02%/C. Cooling: convection, no internal fan Transformers and Filters Humidity Isolation Output Regulation Output Voltage Ripple Output Protection Over-temperature Protection Status Indicator Remote ON/OFF Maximum Capacitive Load Vibration 95% (non-condensing) relative humidity maximum Circuit Protection Shock Enclosure Rating Enclosure Material Mounting Connection Agency Approvals IEC 60068-2-27: 3 axis, 15g half sine, 11ms According to IEC/EN 60950, EN50178, EN61558-2-8, EN60204, CSA Tools Input variation: 0.5% maximum. Load variation (10 to 100%): 0.5% maximum 100 mV peak-to-peak typical (20 MHz bandwidth), (200 mV peak - peak maximum at Imax) Current limit: 110% constant current, automatic recovery, thermal protection, output rating, Voltage limit: 140% Vout nom Switch off at over-temperature, automatic restart Dual color LED (green: DC Ok; Red: DC Off) By external contact. DC On: -S contact open. DC Off: -S connected via 1 K to -Vout, [3VDC max across Vout(+) and Vout(-)] Enclosures Enclosure Climate Control Safety: Electrical Components Unlimited IEC 60068-2-6: 3 axis, sine sweep, 10-55 Hz, 1g, 1 oct/min Safety: Protective Wear IP20 (IEC 529) Terms and Conditions Aluminum (chassis) / zinc plated steel (cover) Snap-on with self-locking spring for 35mm DIN rails per EN 50022-35x15/75, or wall mount with bracket Pluggable screw terminals (plugs included) 2 terminals per output (not available in 600 watt unit.) UL 508 Listed File E197592, UL 60950 Recognized File E198298; CSA C22.2-60950 File 229285; CE Note: Unless otherwise stated all specifications are valid at nominal input voltage, full load and +25°C after warmup time. Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Test Equipment Power Supplies ePW-35 RHINO PSM Series Power Supplies Specifications Prices as of April 16, 2014. Check Web site for most current prices. General Specifications (continued) Specification Standard Document Number Harmonic Limits Harmonic Current Limits EN 61000-3-2, Class A for limited output power Information technology equipment IEC/EN60950; CSA 60950-1-03/UL 60950-1 Industrial control equipment UL 508 Electrical equipment of machines EN 60204 Electronic equipment for power installation EN 50178 Safety, transformers EN 61558-2-8 Limited power source (model PSM24-090S-N) EN 60950 sect. 2.5 and NEC Class 2 Safety Standards Safety Approvals CB-Report per IEC 60950 Safety Class Degree of electrical protection Class1 IEC 536 EMC, Emissions EN 61204-3, EN61000-6-3 Conducted RI suppression on input EN 55011 class B, EN 55022 class B Radiated RI suppression EN 55011 class B, EN 55022 class B EMC, Immunity EN 61000-6-2, EN 61204-3 Electrostatic Discharge (ESD) IEC / EN 61000-4-2 4 kV (contact discharge) / 8 kV (air discharge) Radiated RF field immunity (80-1000 MHz) IEC / EN 61000-4-3 10 V / m Electrical fast transient / burst immunity IEC / EN 61000-4-4 2 kV Surge immunity Immunity to conducted RF disturbances (0.15 to 80 MHz) Power frequency field immunity IEC / EN 61000-4-5 1 kV / 2 kV Voltage dips IEC / EN 61000-4-11(70% UN Crit. B/40%/100% UN Crit. C) Electromagnetic Compatibility (EMC), Emissions Electromagnetic Compatibility (EMC), Immunity Pollution Degree EN 50178, EN 60079-15 EN 61558-2-8, CSA IEC / EN 61000-4-6 10 V IEC / EN 61000-4-8 30 A / m 2* *Note: Normally, only non-conductive pollution occurs. Temporary conductivity caused by condensation is to be expected. A) Output Power Derating vs Ambient Temperature B) 100 100 90 90 80 80 70 PSM 600 60 PSM 078 PSM 156 50 PSM 090 PSM 180 PSM 360 40 30 O utput Power [% Pmax] O utput Power [% Pmax] Output Power Derating 70 60 50 40 30 20 20 10 10 0 -25 40 50 Temperature [˚C] 60 70 Output Power Derating vs Input Voltage 0 85 90 100 110 115 132 187 Input Voltage [VAC] 230 264 Note: Unless otherwise stated, all specifications are valid at nominal input voltage, full load and +25°C after warmup time. Book 3 (14.1) ePW-36 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSM Series Dimensions/Connections Prices as of April 16, 2014. Check Web site for most current prices. PSM12-078S/PSM24-090S PSM24-REM360S PSM24-BCM360S Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories J1 Pin 1 Earth Pin 2 Neutral Pin 3 Line Pin 4 — Pin 5 — J2 J3 J4 GND (-) Vout (+) DC-OK Signal DC-OK Relay contact 1 DC-OK Relay contact 2 S+ Normal mode S- Common — Parallel mode — — — — ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies PSM12-156S/PSM24-180S PSM24-BFM600S DC Converters Transformers and Filters J1 Pin 1 Earth Pin 2 Neutral Pin 3 Line Pin 4 — Pin 5 — Pin 6 — Pin 7 — J2 Circuit Protection J3 J4 Tools GND (-) S+ Normal mode GND (-) S- Common Vout (+) — Parallel mode Vout (+) — — DC-OK Signal — — DC-OK Relay contact 1 — — DC-OK Relay contact 2 — — Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-37 RHINO PSM Series Dimensions/Connections Prices as of April 16, 2014. Check Web site for most current prices. PSM24-360S J1 Pin 1 Earth Pin 2 Neutral Pin 3 Line Pin 4 — Pin 5 — Pin 6 — Pin 7 — J2 J3 J4 GND (-) GND (-) Vout (+) Vout (+) DC-OK Signal DC-OK Relay contact 1 DC-OK Relay contact 2 S+ Normal mode S- Common — Parallel mode — — — — — — — — PSM24-600S J1 J2 J3 J4 J5 Normal DC-OK Relay mode contact 1 DC-OK Relay Pin 2 Neutral GND (-) S- Common contact 2 Parallel DC-OK Signal Pin 3 Line Vout (+) — mode Pin 4 — Vout (+) — — — Pin 1 Earth GND (-) S+ Book 3 (14.1) ePW-38 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSM24-REM360S Redundancy Module Prices as of April 16, 2014. Check Web site for most current prices. Using two PSM24 power supplies and a redundancy module, you can configure a redundant power system, featuring active current sharing, without any additional components. Even if one power supply fails or becomes disconnected, the second unit will supply full current to the load. The module has an alarm contact for monitoring of operations. The inputs are hotswappable and can be loaded up to 15A each. Terminal Blocks Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Redundancy Module Part Number PSM24-REM360S (includes terminal plugs) Company Information Price Input $159.00 Max Power per Input Output Voltage Adjust Output Power Max 2 x 24 VDC 2 x Control Input 24 VDC (24 - 27 VDC) 2 x 360 W 360 W Panel Interface Connectors Wiring Duct Cable Ties General Specifications Operating Temperature Electromagnetic Compatibility Redundancy OK Signal Dimensions Remote Link Wire 0.5m -25°C to +70°C max (-13°F to +158°F), derating above 40°C (104°F) Wire In correspondence to connected units (no internal switching device) Flexible Cord Remote ON/OFF By external contact: ON = J5.3 + J5.4 not shorted OFF = J5.3 + J5.4 shorted Alarm Contact Rating 30 VDC/1.0 A max Trigger threshold at 18 to 22 VDC. Contact closed if one or both inputs failed Multi-conductor Flex Cable Same as model PSM24-090S (see dimensions page) Two cables included with PSM24-REM360S module Data Cables Redundancy Module Connector Positions Redundancy Module Function Diagram Front view 1 2 3 Bottom view Top view J2.3 J1 J2.4 J1.1 J2.1 J2.2 Remote Link 2 Output Remote Link 1 J3.1 PSM J4 1 2 1 2 J3 J3.2 DC Converters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control J1.4 J1.3 Safety: Electrical Components J5 J4.1 PSM Power Supplies Transformers and Filters 4 J2- - + + J1.2 Wire Management Products 1 2 3 4 DC IN 1 DC IN 2 J4.2 J2 Terms and Conditions J1 - + - + J5.1 J5.2 J5.3 J5.4 Note: this redundancy module only works with the PSM series. Other series of power supplies are not compatible. 1 Pin 1 Pin 2 Pin 3 Pin 4 2 3 Safety: Protective Wear 4 J3 J4 Voltage control 1 Voltage control 2 J5 for Input 1 for Input 2 J1 J2 Input 1 -Vin Input 1 +Vin Input 2 -Vin Input 2 +Vin GND (-) S+ GND (-) SVout (+) Vout (+) S+ S— — DC-OK Signal DC-OK Relay contact — — Remote ON/OFF Remote ON/OFF Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-39 RHINO PSM24-BCM360S Battery Control Module Prices as of April 16, 2014. Check Web site for most current prices. The battery control module, when combined with a PSM24 power supply, makes a perfect DC-UPS system by providing the means to charge and monitor an external lead acid battery. The power supply charges the connected battery and keeps it in a charged mode. Consequently, the output voltage of the system is equivalent to the battery voltage. To avoid overcharging the battery, an external temperature sensor (sold separately) automatically adjusts the battery voltage to the required end of charge voltage. This configuration extends the battery life. Battery Control Module Part Number PSM24-BCM360S (includes terminal plugs) Price $157.00 Input Input Power Max 24 VDC power supply and 24 VDC battery Output Voltage Nom *Output Power Max 360 W 24 VDC 360 W *reduce maximum output current by battery charging current. General Specifications Operating Temperature Electromagnetic Compatibility Battery Protection Status Signals Rating per Relay Contact Dimensions Remote Link Wire 0.5m -25°C to +70°C max (-13°F to +158°F) 1.5%/K, derating above 40°C (104°F) In correspondence to connected units (no internal switching device) Over voltage, deep discharge, short-circuit and reverse connection (built-in fuse) DC-OK input, DC-OK output, BAT OK (all relay contacts closed at status OK) 30 VDC / 1.0 A max. Same as model PSM24-090S (see dimensions page) One cable included with PSM24-BCM360S module By external contact: ON = J5.7 + J5.8 not shorted OFF = J5.7 + J5.8 shorted Remote ON/OFF Battery Control Module Function Diagram J1 J2 J3 J4 Pin 1 - Vin (DC In) GND (-) S+ J1.2 J6 J2.3 J2.4 J1.1 J2.1 J2.2 J3.1 PSM J5 15 sec test DC Input-OK Signal J3.2 J1.4 J1.3 Pin 2 + Vin (DC In) GND (-) S- Common Pin 3 - Bat in Vout (+) — 10 min test Pin 4 + Bat in Vout (+) — — Pin 5 — — — — Pin 6 — — — — Pin 7 — — — — Pin 8 — — — — Pin 9 — — — — Pin 10 — — — — DC-OK Relay contact Bat-OK Signal Bat-OK Relay Contact PSM24-360S (factory setting) PSM24-180S PSM24-090S DC Output OK Signal DC Output OK Relay Contact Remote ON/OFF Remote ON/OFF Temperature Sensing Temperature Sensing Battery Control Module Connector Positions J5.1 J5.2 J5.3 J5.4 J5.5 J5.6 J5.7 J5.8 J5.9 J5.10 AC DC Input-OK Battery-OK DC Output-OK Remote ON/OFF Book 3 (14.1) ePW-40 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSM24-BFM600S Buffer Module Prices as of April 16, 2014. Check Web site for most current prices. The buffer module will maintain the output voltage of a 24 VDC power supply after brownouts or voltage dips for up to 200 ms at 25 amps. It is a cost effective alternative to a battery-based backup system. The operation modes are indicated by an LED on the front panel. Company Information Storing the energy in a capacitor bank, this backup solution is completely maintenance free. Its storage capacity does not deteriorate over the lifetime of the unit. Terminal Blocks Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors Buffer Module Part Number PSM24-BFM600S (includes terminal plugs) Price Input $227.00 Operating Voltage Range 24 VDC 22 to 28 VDC Buffer Time Output Power Max 200 msec typical @ 25A max load 4.0 sec maximum @ 1.2A load 25.0 A (600 W) Cable Ties -25°C to +70°C max (-13°F to +158°F), derating above 40°C (104°F) In correspondence to connected units (no internal switching device) Wire Adjustable, >1 V below input voltage, min. 22 VDC Flexible Cord 0.6 A max/30s max Multi-conductor Flex Cable Buffer Active, Buffer Ready (optocoupler output), dual-color LED for status indication Optocoupler input: supply between 5 VDC and 28 VDC to Inhibit Same as model PSM12-156S (see dimensions page) Buffer Module Function Diagram 10 mA Buffer Module Connector Positions 1 2 3 4 5 6 Transformers and Filters Discharge J2.1 Circuit Protection Charge Tools J1.1 Test Equipment J1.2 Enclosures J1.3 J1.4 Wire Management Products DC Converters J2 PSM Data Cables Power Supplies J2.2 Inhibit Panel Interface Connectors Wiring Duct General Specifications Operating Temperature Electromagnetic Compatibility Buffer Voltage Charging Status Signals Inhibit Input Dimensions Signal Output Ratings M12 Junction Blocks Enclosure Climate Control Volt adjust Load Safety: Electrical Components J2.4 Active J2.3 Voltage Detection Voltage Detection Safety: Protective Wear J2.5 Ready Terms and Conditions J2.6 J1 1 2 3 4 5 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 J1 J2 + Vin + Vin - Vin - Vin FG — Inhibit GND Inhibit + Active GND Active Signal Ready GND Ready Signal Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-41 RHINO PSM Power Supplies - Accessories Prices as of April 16, 2014. Check Web site for most current prices. A variety of accessories is available to complement the RHINO PSM power supplies. Choose panel mounting brackets and replacement plug kits from the table below, based on the size of the power supply. There is also a temperature sensor for the battery control module and replacement link cable for the redundancy and battery control modules. Accessories Part Number PSM-PANEL1 PSM-PANEL2 PSM-PK1 PSM-PK2 PSM-PK4 PSM-PK5 PSM-TS PSM-JC01 Price Description $30.00 Panel mounting bracket. 1 bracket type A includes M4-screw (DIN 74-4fA) for 78W, 90W, 156W, 180W PSM power supplies $27.00 Panel mounting bracket. 2 brackets type A include M4-screws (DIN 74-4fA) for 360W, 600W PSM power supplies $6.00 Replacement plug kit for PSM series with 78W and 90W outputs $9.00 Replacement plug kit for PSM series with 156W, 180W and 360W outputs $4.50 Replacement plug kit for PSM series buffer module $17.50 Replacement plug kit for PSM series battery control module $27.00 Temperature sensor for PSM24-BCM360S battery control module $7.00 Replacement link cable for PSM series redundancy module PSM24-REM360S and battery control module PSM24-BCM360S Mounting PSM power supplies are designed for mounting on a DIN rail. Please allow minimum free space of 80 mm (3.15”) above and below, and 50 mm (1.97”) on each side of the power supply for air convection. To attach unit onto the DIN rail, hook the top part of clip on DIN rail, then push down and inward until you hear the clipping sound. To remove, pull the latch of the clip using an insulated flathead screwdriver. For wall or chassis mounting, use mounting brackets PSM-PANEL1 (for 78W to 180W PSM style power supplies) or PSM-PANEL2 (for 360W and 600W PSM power supplies). Remove the DIN clips and replace with the brackets. Use the countersink screws included with the wall mount kit to attach the brackets to the power supply. To attach the power supply to the DIN rail Fig. 2.1 Fig. 2.2 To remove the power supply from DIN rail Fig. 2.3 Fig. 2.4 Book 3 (14.1) ePW-42 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSM Panel Mounting Bracket Dimensions Prices as of April 16, 2014. Check Web site for most current prices. PSM12-078S, PSM24-090S 85.0 (3.35) 42.5 (1.67) ø 4.3 (0.17) ø 4.3 (0.17) (0.17) 7 . 0 (0 . 2 8 ) 15.0 Panel Interface Connectors 5 5 . 0 (2 . 1 6 ) Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables PSM24-360S 46.0 (1.81) Wire Management Products 33.0 (1.30) 96.0 (3.78) 25 (0.98) Power Supplies 2 . 0 (0 . 0 8 ) (0.17) 2x ø4.3 (0.17) DC Converters 6 2 . 5 (2 . 4 6 ) ø 4.3 5 0 . 0 (1 . 9 7 ) 3 0 . 0 (1 . 1 8 ) M12 Junction Blocks Wiring Duct 15.0 (0.59) Material: 2 mm Mild Steel Tolerance: ±0.1mm (± 0.004) PSM-PANEL2 Wiring Accessories Sensor Cables and Connectors PSM12-156S, PSM24-180S 4 x positioning holes (0.59) Power Distribution Blocks Multi-wire Connectors 5 5 . 0 (2 . 1 6 ) ø 4.3 Terminal Blocks ZIPLink Connection System 34.5 (1.36) 3 1 . 0 (5 . 0 6 ) 34.5 (1.36) 2 . 0 (0 . 0 8 ) PSM-PANEL1 Company Information Transformers and Filters Circuit Protection Tools 2 . 0 (0 . 0 8 ) PSM24-600S Test Equipment 4 x positioning holes Enclosures Enclosure Climate Control Safety: Electrical Components 6 2 . 5 (2 . 4 6 ) (0.59) 7 . 0 (0 . 2 8 ) 173.0 (6.81) 15.0 Safety: Protective Wear Material: 2 mm Mild Steel Tolerance: ±0.1mm (± 0.004) Terms and Conditions Dimensions: [mm] ( ) = Inch Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-43 Build your control system for less! with our everyday low prices on high-quality components From cable to wire duct ... Multi-Conductor Control Cable 100-foot reels start at: $50.00 (V40166-100) Flexible multi-conductor control cable is suitable for wet and dry locations, and is resistant to sunlight, oil and moisture penetration. • • • • Conductor sizes from 18 to 10 gauge 3 to 41 unshielded conductors Available in 100, 250, 500 and 1,000-foot reels UL and CSA approved, RoHS compliant Wire Duct starting at: $12.00 (single piece) or $184.00 (20-piece pack) Heavy-duty multi-wire connectors quickly and reliably connect wiring in applications such as machinery, robots, and control and signal circuits. • • • • Multi-Wire Connectors Build custom connectors from components WRSLQFRQoJXUDWLRQV 3A to 32B sizes Bulkhead or surface mount housings with standard or automatic covers All components sold separately Keep your wiring in order with Iboco rigid or flexible wire duct in a choice of styles and colors. • • • 6WDQGDUGRUWKLQoQJHUVORWWHGVW\OHVDQGVROLGGXFW for special applications 6WDQGDUGGXFWLQJUD\EOXHDQGEODFN Sold per 2-meter piece for convenience or in cost-saving multi-packs Research, price, buy at: www.automationdirect.com/ wiring-solutions Also Available Enclosures Wiring Devices Terminal Blocks Order Today, Ships Today! * See our Web site for details and restrictions. © Copyright 2014 AutomationDirect, Cumming, GA USA. All rights reserved. Tools Cat5e Cables 1-800-633-0405 Field Wireable Connectors Cable Ties & Accessories the #1 value in automation RHINO PSP Series 5,12 & 24 VDC Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Starting at $56.00 Screw terminals or spring clamp Slimline Power Supplies RHINO PSP series power supplies are plastic housed ultracompact switching supplies available in 5V, 12V and 24V adjustable models. There are 13 models available with power ratings of 20W to 240W and up to 10A output current. They are DIN rail or panel-mountable and feature universal inputs, adjustable DC voltage outputs, power good signal and feature low output ripple along with short circuit, overvoltage and overload protection. Power good signal Power ON LED Output voltage adjust Slim, stylish plastic case Universal input DIN-rail mount PSP24-060S PSP24-024S Terminal Blocks Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors The RHINO PSP series of switching power supplies offer an excellent price/performance ratio. They provide tightly regulated output voltage for sensitive loads in industrial environments. The slim plastic case is lightweight and compact, and comes in both screw and spring clamp terminal versions. The constant-current, short-circuit protection limits the output current as the voltage is reduced, to safely protect the control components from direct shorts and device failures. Once a fault is corrected, the power supply automatically resumes supplying full-voltage power. (PSPxx-024x models have foldback current protection with autorecovery.) The RHINO PSP power supplies have a Power ON LED for easy visual indication of operation as well as a Power Good signal for feedback to your system controller. M12 Junction Blocks Features Transformers and Filters With a UL 508C rating, the RHINO PSP series is the right choice for space limited applications. PSP24-120S Company Information • Regulated switch mode type • Ultra-compact plastic case • Finger-safe terminals • Reliable snap-on mounting on DIN-rails • Wall mounting bracket included • Universal input 85-264 VAC, 50/60 Hz or 85-375 VDC (85-132/187-264 VAC only for PSP24-240S input) • Models with 5, 12 or 24 VDC output • Output voltage adjustable • Parallel operation up to five units (not PSP24-240S) • Power good signal (some models) • Low ripple and noise • Overload and short-circuit protection • UL/cUL 508 listed, UL/cUL 60950 recognized* • Worldwide safety approvals • 3-year product warranty PSP12-120C PSP12-060C PSP24-024C * Note: PSP24-240S is not cUL listed. PSP05-020S, PSP12-024S, and PSP24-240S are not UL 60950 recognized. Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-45 Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions RHINO PSP Series Power Supplies Specifications Prices as of April 16, 2014. Check Web site for most current prices. Input Specifications Part Number 30% output derating below 93 VAC/ 130 VDC PSP05-020S PSP05-020S PSP12-024S PSP24-024S PSP24-024C PSP12-024S PSP24-024S PSP24-024C PSP12-060S PSP12-060C PSP24-060S PSP24-060C PSP12-120S PSP12-120C PSP24-120S PSP24-120C PSP24-240S Input Input Current C-Curve Circuit Freq. (Typical) at full load Efficiency Breaker or Range 115 VAC 230 VAC (Typ.) Slow-blow Fuse Input Voltage Range 0.35 A 0.2A 88% 20% output derating below 93 VAC/ 130 VDC 85-264 VAC 85-375 VDC 47-63 Hz 0.35 A 0.2 A 1.2 A 0.6 A 2.0 A 1.0 A 88% 5.0 A 15% output derating below 93 VAC/ 130 VDC 88% 85-132/ 187-264 VAC 20% output derating below 93 VAC 4.7 A 2.0 A Output Specifications Part Number PSP12-060S PSP24-060S PSP12-060C PSP24-060C PSP05-020S PSP12-024S PSP24-024S PSP24-024C PSP12-060S PSP12-060C PSP24-060S PSP24-060C PSP12-120S PSP12-120C PSP24-120S PSP24-120C PSP24-240S Price Output Voltage Output Volt. Output Current Adjust. Range (Max.) Output Power (Max.) $77.00 5.1 VDC 5-5.25 VDC 4.0 A 20 W $73.00 12 VDC 12-16 VDC 2.0 A 24 W 24 VDC 24-28 VDC 1.0 A 24 W 12 VDC 12-15 VDC 4.0 A 24 VDC 24-28 VDC 2.5 A 12 VDC 12-15 VDC 8.0 A $56.00 $59.00 $97.00 $107.00 $85.00 $86.00 $153.00 $158.00 60 W $135.00 $142.00 24 VDC $180.00 24-28 VDC Hold-Up Time 115 VAC 230 VAC MTBF (IEC 1709 @ 25°C) 2,681,000 hours 15 ms 125 ms 2,947,000 hours 120 W 1,620,000 hours 240 W 1,912,000 hours 5.0 A 10.0 A Part numbering system PSP12-120C PSP24-120C PSP24-120S PSP12-120S PSP24-024S PSP24-240S Terminal Connector Type: C: Clamp S: Screw Output Watts The unit can be mounted on a chassis or wall using the included mounting bracket. Output Volts PSP: Series Name Book 3 (14.1) ePW-46 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSP Series Power Supplies Dimensions Prices as of April 16, 2014. Check Web site for most current prices. General Specifications Operating: -10°C to +70°C (14°F to 158°F), Derating at 93-132 VAC or 130-187 VDC: -1.10%/C above 40°C, Derating at 187-264 VAC or 265-375 VDC: -1.67%/C above 50°C, Derating at 85-93 VAC or 85-130 VDC: -1.30%/C above 30°C, Temperature Coefficient: 0.02%/C Storage: -25°C to +85°C (-13°F to 185°F) Temperature Humidity Output Regulation Switching Frequency Safety Standards Output Voltage Ripple 95% (non-condensing) relative humidity max. Output Protection Current Limit at 120% typ., constant current, auto recovery (PSPxx-024x foldback, auto-recovery), Voltage Limit <40 VDC Power Good Signal* Trigger Point 12 VDC Models: >11 V 24 VDC Models: >22 V 55 - 180 kHz depending on load IEC/EN 60950 (output SELV), UL 60950, UL 508, EN 50178, EN 60204, EN 61558-2-8 M12 Junction Blocks Panel Interface Connectors EN 61000-3-2, EN 61000-6-2, EN 61000-6-3 Agency Approvals UL/cUL 508 listed File E197592(PSP24-240S not cUL), UL 60950 recognized, file E198298 (except PSP05-020S, PSP12-024S and PSP24=240S). IP 20 Wiring Duct Plastic FR2010-110C (UL 94 V-O rated) Cable Ties 35 mm DIN rails, snap on with self-locking spring or wall mount adapter included S models: Plug-in Screw Terminals, C Models: Clamp Terminals. For 28-12 AWG wire Wire Flexible Cord *Note: PSP05-020S, PSP12-024S and PSP24-024x models do not have Power Good output. Multi-conductor Flex Cable Note: All specifications are valid at nominal input voltage, full load and +25°C after warmup time, unless otherwise stated. PSP05-020S, PSP12-024S, PSP24-024x PSPxx-060x 100.0 (3.94) 100.0 (3.94) 1 2 3 INPUT 1 2 3 INPUT 3.2 (0.13) 35 (1.38) DC Converters Transformers and Filters 45 (1.77) 27 (1.06) Input Weight: 140g (4.9 oz.) Output 1 2 PSPxx-120x Weight: 265g (9.4 oz.) TCL 240 model 100.0 (3.94) 1 2 3 4 5 85 (3.35) 1 Input Weight: 440g (15.5 oz.) 85 (3.35) 2 3 INPUT Input Output 1 AC Ground 1 +Vout 2 Neutral 2 +Vout 3 Line 3 -Vout 4 -Vout 5 Power Good Enclosures Terms and Conditions 35 (1.38) 35 (1.38) 3.2 (0.130) 110 (4.33) Output voltage adjust 75.0 (2.95) 1 2 3 INPUT Test Equipment Safety: Protective Wear DC-ON LED DC-ON LED Output voltage adjust Tools Safety: Electrical Components 125(4.92) OUTPUT Circuit Protection Enclosure Climate Control PSP24-240S Note: All dimensions are in millimeters (inches). OUTPUT 1 2 3 4 5 Output 1 AC Ground 1 +Vout 2 Neutral 2 +Vout 3 Line 3 -Vout 4 -Vout 5 Power Good +Vout -Vout DIN rail mounting hooks 20mm (0.79) wide Wire Management Products Power Supplies 75.0 (2.95) DC-ON LED Output voltage adjust 35 (1.38) 2.2 (0.09) 75.0 (2.95) Data Cables OUTPUT 1 2 3 4 5 OUTPUT 1 2 AC Ground Neutral Line Wiring Accessories Sensor Cables and Connectors Output Signal (reference to -Vout) 11.0 V+/- 1.0 V @ 60 mA max. 22.0 V+/- 2.0 V @ 30 mA max. Input Power Distribution Blocks Multi-wire Connectors <50 mV peak-to-peak 1 2 3 Terminal Blocks ZIPLink Connection System 2.5% (1% for PSP12-060x), 10 to 90% load variation Electromagnetic Compatibility (EMC) Enclosure Rating Enclosure Material Mounting Connection DC-ON LED Output voltage adjust Company Information Weight: 950g (33.5 oz.) Output 1 AC Ground 1 +Vout 2 Neutral 2 +Vout 3 Line 3 -Vout 4 -Vout 5 Power Good Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-47 RHINO PSP24-REM240S Redundancy Module Prices as of April 16, 2014. Check Web site for most current prices. The PSP24-REM240S redundancy module used with two Rhino PSP Series power supplies creates redundancy to help prevent costly downtime due to power supply failure. The PSP24-REM240S decouples the outputs of the two connected power supplies so that in case of failure, one power supply cannot overload the other. PSP Redundancy Module Part Number Price PSP24-REM240S $47.00 Input Voltage Range Max Power per Input Current Connection Output Voltage Output Max. 2 x 5 – 60 VDC 144 W V in - 0.9 VDC Detachable screw terminal block 8A PSP24-REM240S General Specifications Temperature Operating: -10°C to +70°C max (14°F to +158°F max), Storage: -25°C to +85°C max, (-13°F to +185°F max), Cooling: Natural air convection Parallel Operation Electromagnetic Compatibility Enclosure Material Mounting Indication Connections Wire Size range Dimensions Agency Approvals (2) Rhino PSP power supplies (except PSP24-240S) per module In correspondence with connected power supplies Gray plastic, FR2010-110C (UL94 V-0 rated) Built-in snap-on connection for 35mm DIN rail or surface mount adapter included Green LED for Output ON Plug-in screw terminals, 0.5 to 0.7Nm (4.5 to 6.2lb-in) recommended tightening torque 24 to12 AWG (0.21 to 3.16 mm2) HxWxD 2.95” x 1.06” x 3.94” (75 x 27 x 100mm) UL/cUL 508 listed, File E197592, CE Redundancy Module Function Diagram – Failure + Monitor Load 8A Max. + – Redundancy Module Connector Positions – Failure + Monitor 100.0 (3.94) OUTPUT 1 2 + + – – + + PSP24 PSP24 PSP24REM240S V in 2 V in 1 Com N L N DC-ON LED 1 2.2 (0.09) V Out DC-OK 35 (1.38) DC-OK 75.0 (2.95) + + – – 2 3 INPUT 27 (1.06) L Input L1 L2 N 5.0A C-curve circuit breaker or slow blow fuse 5.0A C-curve circuit breaker or slow blow fuse Output 1 +Vin1 1 +Vout 2 +Vin2 2 +Vout 3 Common Recommendations for redundant PSP Series power supply applications: • With no load connected, adjust the output voltage of both power supplies to the same value. • Use separate input over-current protection for each power supply. • When possible, connect the input power to each power supply to different phases or circuits. • Use the DC-OK output and/or DC-ON LED on each power supply to monitor for failure. (PSP05-020S, PSP12-024S and PSP24-024x do not have DC-OK output). • Connect all output leads together at a single distribution node using leads having the same length and cross section. Book 3 (14.1) ePW-48 Power Supplies 1 - 80 0 - 633 - 0405 RHINO PSC Series Power Supplies Specifications Prices as of April 16, 2014. Check Web site for most current prices. NEC Class 2 Compliant Supplies PSC-05-012, PSC-12-015, PSC-24-015 PSC-12-030, PSC-24-030 The RHINO PSC series power supplies are plastic low-profile housed switching supplies available in 5, 12 and 24 VDC adjustable output models. There are 8 models with power ratings from 12W to 90W. They have an integral DIN rail mounting adapter and feature universal 85 to 264 VAC input voltage, adjustable DC output, DC-OK LED indication, and output current limitation. The RHINO PSC series is both UL508 listed for demanding industrial applications and UL1310 recognized for NEC Class 2 compliance in industrial, commercial and residential applications. Features The RHINO PSC series of switching power supplies provide tightly regulated output voltage for sensitive loads in industrial, commercial and residential environments. The plastic housing is lightweight and low-profile, designed to fit in shallow depth control panels often used in the building automation industry. Screw terminals are provided for simple and speedy wiring terminations. • Low-profile housing - only 2.15 inches (55mm) deep (MCB form factor) • 5, 12, 24VDC adjustable outputs • Output power ratings from 12 to 90W • Integral DIN rail mouting adapter • Universal input voltage range 85-264VAC • Tight output voltage regulation • DC-OK LED indication • UL508 Listed • UL1310 Recognized for NEC Class 2 compliance • CE compliant • RoHS compliant Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies PSC-24-090 PSC-12-060, PSC-24-060 DC Converters Input Specifications Part Number PSC-05-012 PSC-12-015 PSC-24-015 PSC-12-030 PSC-24-030 PSC-12-060 PSC-24-060 PSC-24-090 Input Voltage Range Input Frequency Range Input Current (Typical) at Efficiency full load (Typ.) 115 VAC 230 VAC 0.25A typ. 0.17A typ. 0.29A typ. 0.20A typ. 0.57A typ. 0.39A typ. 1.00A typ. 0.68A typ 83% 1.10A typ. 0.70A typ. 85% 1.60A typ. 1.07A typ. 86% 100-240VAC - Nominal 85 to 264VAC - Universal (output power derating 5% / V for operation below 90 VAC) 47-63 Hz Transformers and Filters C-Curve Circuit Breaker or Slowblow Fuse Circuit Protection 73% Tools 79% 81% 81% 83% Test Equipment 6.0 A Enclosures Enclosure Climate Control Safety: Electrical Components Output Specifications Part Number PSC-05-012 PSC-12-015 PSC-24-015 PSC-12-030 PSC-24-030 PSC-12-060 PSC-24-060 PSC-24-090 Price Output Voltage Output Volt. Adjust. Range Output Current (Max.) Output Power (Max.) $45.00 5.0VDC 5.0 to 5.2VDC 2.4A $45.00 12.0VDC 12.0 to 16.0VDC 1.25A $45.00 24.0VDC 24.0 to 28.0VDC 0.63A $57.00 12.0VDC 12.0 to 16.0VDC 2.5A $57.00 24.0VDC 24.0 to 28.0VDC 1.25A $69.00 12.0VDC 12.0 to 16.0VDC 4.5A 54 Watt $69.00 24.0VDC 2.5A 60 Watt $87.00 24.0VDC 3.75A 90 Watt 24.0 to 28.0VDC Hold-Up Time 115 VAC 230 VAC MTBF (IEC 1709 @ 25°C) 12 Watt 1,600,000 hours 15 Watt 30 Watt minimum 10 ms minimum 20 ms 1,300,000 hours 2,100,000 hours 1,300,000 hours Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-49 Safety: Protective Wear Terms and Conditions RHINO PSC Series Power Supplies Specifications and Dimensions Prices as of April 16, 2014. Check Web site for most current prices. General Specifications Operating:: -25°C (-13°F) to +60°C (+140°F) max at nominal load, above +60°C (+140°F) 2.5% / °C derating up to +70°C (+185°F) Storage:: -25°C (-13°F) to +85°C ( +185°F) max Temperature Humidity Output Regulation 95% (non-condensing) relative humidity max. 1% UL508, UL1310, Class 2 IEC/EN 60950-1, UL60950-1, EN50178 EN60204, EN61558-2-8 <100 mV peak-to-peak Safety Standards Output Voltage Ripple Output Protection Electromagnetic Compatibility (EMC) Enclosure Rating Enclosure Material Mounting Connection Plastic FR2010-110C (UL 94V- 0 rated) DIN-rails as per EN50022-35x15/735 (snap-on with self-locking springs) Screw terminals with combi-type screw heads for wire size 24 to 12 AWG (0.20 to 3.30mm²) UL508 Listed, file #E197592 UL1310 Class 2 Recognized, file #E198298 Agency Approvals Part No. PSC-05-012 PSC-12-015 PSC-24-015 PSC-12-030 PSC-24-030 PSC-12-060 PSC-24-060 PSC-24-090 Current limitation at 100 - 150% typ. (automatic recovery) Emissions - EN61000-6-3 Immunity - EN61000-6-2 Conducted RI suppression on input - EN55022 class B EN61000-4-X Radiated RI suppression - EN55022 class B IP 20 (IEC 60529) Dimensions Width (W) - mm [inches] Weight oz [g] 26.3 [1.04] 3.53 [100] 26.3 [1.04] 3.53 [100] 26.3 [1.04] 3.53 [100] 52.5 [2.07] 5.64 [160] 52.5 [2.07] 5.64 160] 70.0 [2.76] 8.11 [230] 70.0 [2.76] 8.11 [230] 105.0 [4.13] 12.0 [340] Input/Output AC Input DC Output DC Output Wiring Description Wire size all models: L, N only (2 pin terminal) 24 -12 AWG / 3.30mm² max 15 -30 Watt models: single + and - terminals 24 -12 AWG / 3.30mm² max 60 - 90 Watt models: double + and - terminals 24 -12 AWG / 3.30mm² max TOLERANCE +/- 0.5mm [0.02”] Book 3 (14.1) ePW-50 Power Supplies 1 - 80 0 - 633 - 0405 PS Series 12 VDC and 24 VDC Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Switching power supplies at linear supply prices Removable plug terminals: • Easy to install and disconnect wiring Sturdy DIN-rail mounting: • Easy to mount and remove, but still secure These power supplies use efficient switching technology to produce the most power in the smallest space, while generating a minimum amount of heat. The constant-current short circuit protection limits the output current as the voltage is reduced to safely protect your control components from direct shorts and device failures. Once the short is corrected, the PS Series power supplies automatically resume supplying fullvoltage power. Precisely regulated output power is suitable for battery charging applications. Extra-sturdy DIN rail mounts and removable plug connections make installation a breeze. Features • 2A - 24A at 24 VDC, 3.5A at 12 VDC • Regulated switch mode type • Low profile case • Easy DIN-rail mounting • Constant-current short circuit protection • Low ripple and noise • Selectable input voltage (115/230 VAC) • High EMC immunity • EMI meets EN 55011-B and FCC Part 15, Level B • Worldwide safety approvals: UL/cUL 508, 60950 and 1604 Class I, Div. 2 , CE Terminal Blocks Power Distribution Blocks Wiring Accessories The PS Series power supplies give you consistent, reliable, switched DC power at linear power supply prices. Meeting UL/cUL 60950, 508 and 1604* (Class I, Div. 2), our PS-D (DIN-rail mounted) power supplies meet the standards required for practically any industrial control application. Company Information ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Power ON LED: • Quick visual check for troubleshooting Wiring Duct Cable Ties Wire Flexible Cord Durable metal case: • A reliable industrial duty package Multi-conductor Flex Cable Data Cables Wire Management Products Constant current protection with auto-recovery: • No current spikes to damage powered devices due to improper wiring or a powered device failure Efficient switching technology: • Smaller size and less heat generated results in less wasted space and energy DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components * (PS12-050D, PS24-050D and PS24-500D do not meet UL 1604 Class I Div 2) Part numbering system PS12-050D D: DIN-Rail Mounting Output Watts Output Volts PS: Series Name Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies Power Supplies ePW-51 Safety: Protective Wear Terms and Conditions PS Series Power Supplies Specifications Prices as of April 16, 2014. Check Web site for most current prices. General Specifications PS12-050D PS24-050D PS12-075D PS24-075D Temperature Operating (ambient): -25°C to + 70°C (-13°F to 158°F) max, Derating above 50°C 2%/C Storage (non-operating): -25°C to + 85°C (-13°F to 185°F) max, Temperature drift: 0.02%/C Humidity Switching Frequency Isolation 95% (non-condensing) relative humidity max Output Regulation Output Voltage Ripple Output Protection Vibration Shock Enclosure Rating Enclosure Material Mounting Connection Agency Approvals 80 kHz typical (PWM) According to IEC/EN 60950, UL 60950, UL 508 Input variation: ± 0.2% max Load variation: 50 W, 75 W, 150 W models: ± 1% max . . . . . . . . . . 300 W, 500 W, 600 W models: ± 0.3% max < 50 mV peak to peak (20 MHz bandwidth) Current limit: 110% maximum output rating. Voltage limit: 140% Vout nom 1gn 20 sweeps each axis 15gn, 11mS each axis IP 20 Aluminum (chassis) / stainless steel (cover) Snap-on with self-locking spring for 35mm DIN rails Removable screw terminals for 22-10 AWG UL/cUL 60950 recognized, file E198298, UL/cUL 508 listed File E197592, UL/cUL 1604 listed (Class I, Div 2, groups A,B,C, and D hazardous locations), File E197886, except PSxx-050D and PS24-500D, which are not UL/cUL1604 listed. CE Note: All specifications are valid at nominal input voltage, full load and +25°C after warm-up time, unless otherwise stated. Input Specifications PS24-150D PS24-300D Input Current Inrush Current Voltage Input (Typical) (<2mS) Part Number Input Frequency Range Range 115 VAC 230 VAC 115 VAC 230 VAC 1.2 A 0.7 A PS12-050D 93-264 VAC <15 A <30 A 1.2 A 0.7 A PS24-050D 93-264 VAC 1.7 A 0.9 A PS12-075D <16.5 A <33 A 1.7A 0.9 A PS24-075D 93-132 VAC 187-264 VAC 3.0 A 1.7 A PS24-150D (switch selectable) 47-63 Hz <35 A <70 A 5.4 A 3.3 A PS24-300D 9.5 A N/A <50 A N/A PS24-500D 93-132 VAC PS24-600D 93-132 VAC 187-264 VAC (switch selectable) 10.5 A 6.4 A <70 A <80 A C-Curve Efficiency Circuit Breaker or (Typ.) Slow-blow Fuse 84% 87% 83% 5.0 A 85% 84% 87% 87% 88% 10.0 A 15.0 A 20.0 A Output Specifications Part Number Price PS24-500D PS24-600D PS12-050D PS24-050D PS12-075D PS24-075D PS24-150D PS24-300D PS24-500D PS24-600D Output Output Output MTBF Hold-Up Time Output Output Voltage Current Power Voltage 1709 Voltage Adj. Range (Max.) (Max.) Regulation* 115 VAC 230 VAC (IEC @ 25°C) $113.00 12 VDC 12-14 VDC 3.5 A 50 W $103.00 24 VDC 24-28 VDC 2.0 A 50 W $165.00 12 VDC 12-14 VDC 6.0 A 75 W 3.0 A 75 W 6.0 A 150 W 12.0 A 300 W $397.00 20.0 A 500 W $405.00 24.0 A 600 W $115.00 $184.00 $233.00 24 VDC *Load variation (10-90%) 24-28 VDC 2,992,000 hours 1% 25 mS 30 mS 1,800,000 hours 1,939,000 hours 1,913,000 hours 0.3% 20 mS N/A 1,467,000 hours 15 mS 25 mS 1,434,000 hours Notes: Output current characteristic suitable for battery charging applications. Not recommended for redundancy or parallel operation. Replacement terminal blocks are available. See price list. Book 3 (14.1) ePW-52 Power Supplies 1 - 80 0 - 633 - 0405 PS Series Power Supplies Dimensions Prices as of April 16, 2014. Check Web site for most current prices. PS12-050D, PS24-050D PS24-300D Company Information Terminal Blocks Note: All dimensions are in millimeters (inches). Tolerances ±0.5mm Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct PS12-075D, PS24-075D Cable Ties PS24-500D Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection PS24-150D Tools PS24-600D Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-53 RHINO PSE Series Encapsulated Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. The PSE series are AC/DC switch mode power supplies encapsulated in an ultra-compact, low profile housing. They are ideal for space limited applications and are easily screw mounted to a panel or equipment chassis, or can be DIN rail mounted using the optional DIN rail mounting kit. The PSE series features a universal input from 85-264 VAC and single or dual outputs from 15 Watts up to 60 Watts (above 30 Watt, single output only). Features • Ultra compact, low profile plastic case • Single or dual output models • Screw terminal blocks • Chassis mount or 35mm DIN rail mount with optional adaptor • Universal input 85-264 VAC, 47-440 Hz (60 Watt, 47-63 Hz) • Double insulated - no external ground required • UL508 listed, UL60950-1 recognized, CE marked • Short circuit and overload protection • DC on LED indicator • 3-year warranty Single Output Models 15 to 60 Watt Part No. Price Weight (lbs) PSE05-115 $50.00 0.3 Output Power Max. Output PSE12-115 $50.00 0.3 PSE15-115 $50.00 0.3 15 VDC / 1000 mA PSE24-115 $50.00 0.3 24 VDC / 625 mA PSE05-130 $72.00 0.5 5 VDC / 6000 mA PSE12-130 $72.00 0.5 PSE15-130 $72.00 0.5 15 VDC / 2000 mA PSE24-130 $72.00 0.5 24 VDC / 1250 mA PSE05-150 $87.00 0.8 PSE12-160 $87.00 0.8 PSE15-160 $87.00 0.8 PSE24-160 $87.00 0.8 5 VDC / 3000 mA 12 VDC / 1250 mA 15 Watt 12 VDC / 2500 mA 30 Watt 51 Watt 5.1 VDC / 10,000 mA 12 VDC / 5000 mA 60 Watt 15 VDC / 4000 mA 24 VDC / 2500 mA Dual Output Models 15 to 30 Watt Part No. Price Weight (lbs) PSE12-215 $52.00 0.3 PSE15-215 $52.00 0.3 PSE12-230 $75.00 0.5 PSE15-230 $75.00 Output Power Max. Output 1 Output 2 +12 VDC / 650 mA -12 VDC / 650 mA +15 VDC / 500 mA -15 VDC / 500 mA +12 VDC / 1300 mA -12 VDC / 1300 mA +15 VDC / 1000 mA -15 VDC / 1000 mA 15 Watt 30 Watt 0.5 Book 3 (14.1) ePW-54 Power Supplies 1 - 80 0 - 633 - 0405 PSE Series Encapsulated Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories ZIPLink Connection System Input Specifications Input Voltage Multi-wire Connectors Nominal 100 - 240 VAC AC range (universal input) 85 - 264 VAC DC range 120 - 370 VDC (not for 60 Watt models) Input Frequency Sensor Cables and Connectors 47 - 440 Hz (47 - 63 Hz for 60 Watt models) Input Current at Full Load (115 VAC / 230 VAC) 15 Watt models 300 mA / 190 mA typ. 30 Watt models 550 mA / 330 mA typ. 51/60 Watt models (typical for all) 1050 mA / 670 mA typ. Input Current at No Load M12 Junction Blocks Panel Interface Connectors Wiring Duct 15 mA @ 115 VAC & 20 mA @ 230 VAC typ. Inrush Current (< 2ms, cold start at 115 VAC / 230 VAC) External Input Fuse Required (recommended value) 15 Watt models 15A / 30A Cable Ties 30 Watt models 20 A / 40 A Wire 60 Watt models 30 A / 50 A 15 and 30 Watt models 1.5 A slow blow 51/60 Watt models 3.0 A slow blow Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies Output Specifications DC Converters 2% Voltage Set Accuracy 1% max. Load variation Single output models (10-100%): 1% max. Dual output models balanced load (10-100%): 2.5% max. Dual output models unbalanced load (20/100%): 5.0% max. Single and dual output models 10% of rated max. current 5.0 VDC outputs 1.8% of Vout [mVpk-pk] All other outputs 1.3% of Vout [mVpk-pk] Regulation Minimum Load Ripple and Noise (20MHz bandwidth) Transformers and Filters Input variation Overload Protection by Current Limit Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control 105% min. of nominal current, fold back, automatic recovery (long term overload condition may cause damage to the power supply) Safety: Electrical Components Model Series Output PSE15 Max. Capacitive Load [µF] Single Output Models Dual Output Models PSE30 Safety: Protective Wear PSE60 5.0 VDC; 5.1 VDC 3900 8000 8000 12 / 15 VDC 2200 3900 3900 24 VDC 1000 1500 1500 +/-12 V; +/-15V 1500 1500 NA Terms and Conditions Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-55 PSE Series Encapsulated Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. General Specifications Operating Temperature Model Series Standard/ Approval PSExx-115 PSExx-130 PSExx-150 PSExx-160 IEC/EN60950-1 -25°C to +71°C (-13°F to +159.8°F) -25°C to +71°C (-13°F to +159.8°F) -10°C to +40°C (14°F to +104°F) -10°C to +50°C (14°F to +122°F) UL508 -25°C to +50°C (-13°F to +122°F) -10°C to +40°C (14°F to +104°F) Storage Temperature -25°C to +50°C (-13°F to +122°F) -10°C to +40°C (14°F to +104°F) -40° to 185°F (-40° to 85°C) 3.75% per °C above +122°F (50°C) 2.5% per °C above +104°F (40°C) (for PSE05-150) Power Derating Temperature Coefficient 0.02 %/°C Humidity (non-condensing) 95% rel. H max. Efficiency 78% typ. Switching Frequency Isolation Voltage (60 sec.) Isolation Resistance 100 kHz typ. (fixed) Input/Output 3,000 VAC Input/Output 100 MΩ (@ 500 VDC) Electromagnetic Compatibility (EMC), Emissions EN 61000-6-3: 2007 EN61204-3: 2000, class A EN 55022, level B, FCC Part 15 level B EN61000-6-2: 2005 EN61204-3: 2000, class A Electromagnetic Compatibility (EMC), Immunity Electrostatic discharge ESD EN61000-4-2 - 8kV / 4 kV, criteria B RF field susceptibility EN61000-4-3 - 10 V/m, criteria A Electrical fast transient / burst immunity input EN61000-4-4 - 2 kV, criteria B Electrical fast transient / burst immunity output EN61000-4-4 - 2 kV, criteria B Surge immunity line - neutral EN61000-4-5 - 1 kV, criteria B Surge immunity output EN61000-4-5 - 0.5 kV, criteria B Immunity to conducted RF distrubances EN61000-4-6 - 10 V, criteria B Mains voltage dips and interruptions EN61000-4-11 - 30% 10 ms, criteria B, 60% 100 ms, criteria C, 95% 5000 ms, criteria C Protection Class II Safety Standards Agency Approvals to IEC/EN 60536 Information technology equipment IEC/EN 60950-1, UL 60950-1 UL and cUL for UL 508, Listed file #E197592; UL and cUL for UL 60950-1, Recognized file #E198298; CE RoHS Compliant Yes Vibration None Shock None Reliability / Calculated MTBF (MIL-HDBK-217F, @ +25°°C, ground benign) Casing Material Mounting Screw Torque Specifications 15 Watt Models >280,000 hours 30 Watt Models >250,000 hours 60 Watt Models >125,000 hours Plastic resin + fiberglass (UL 94V-0 rated) 4~5 in-lb [0.45~0.56 Nm] Note: All specifications valid at nominal input voltage, full load and +25°°C after warm-up time unless otherwise stated. Book 3 (14.1) ePW-56 Power Supplies 1 - 80 0 - 633 - 0405 PSE Series Encapsulated Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. Derating Curves Terminal Blocks Power Distribution Blocks PSE 51 & 60W Models PSE 15 & 30W Models 100 100 80 80 Output Power (%) Output Power (%) Company Information 60 40 Wiring Accessories ZIPLink Connection System other PSE05-150 60 Multi-wire Connectors 40 Sensor Cables and Connectors 25% 20 25% 20 0 0 -25 -13 10 50 20 68 30 86 40 104 50 122 60 70 °C -25 10 20 140 158 °F -13 50 68 PSE 15W models for chassis mount Ambient Temperature 30 40 50 60 70 °C 86 104 122 140 158 °F Ambient Temperature M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Connection Pin #4 screw size, Typ Single Dual (12V, 15V) 1 AC(N) - AC Neutral 2 AC(L) - AC Line 3 NC 4 -Vout 5 NC Data Cables Wire Management Products Common 6 +Vout 7 NC Multi-conductor Flex Cable Power Supplies DC Converters Transformers and Filters Circuit Protection Tools PSE 30W models for chassis mount Test Equipment Dimensions mm [inches] Enclosures Enclosure Climate Control Connection #4 screw size, Typ Pin Single Dual (12V, 15V) 1 AC(N) - AC Neutral 2 AC(L) - AC Line 3 +Vout 4 NC 5 -Vout 6 7 Safety: Protective Wear Terms and Conditions Common NC NC -Vout Dimensions mm [inches] Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Safety: Electrical Components Power Supplies ePW-57 PSE Series Encapsulated Power Supplies Prices as of April 16, 2014. Check Web site for most current prices. PSE 60W models for chassis mount Connection #4 screw size, Typ Pin Function 1 AC(N) - AC Neutral 2 AC(L) - AC Line 3 NC 4 +Vout 5 NC 6 -Vout 7 NC Dimensions mm [inches] 35mm DIN Rail Mounting Bracket Part No. PSE-BRKT-1 PSE-BRKT-2 Price Weight (lbs) Description $9.00 0.2 DIN rail mounting bracket for 15W models $10.00 0.2 DIN rail mounting bracket for 30W, 51W and 60W models Note: Kit contains interface plate, DIN rail clip and necessary screws. PSE-BRKT-1 PSE-BRKT-2 Dimensions mm [inches] Book 3 (14.1) ePW-58 Power Supplies 1 - 80 0 - 633 - 0405 RHINO DC to DC Converters Prices as of April 16, 2014. Check Web site for most current prices. Company Information Terminal Blocks Power Distribution Blocks Four models for DC input voltage are available in the PSP series of DIN-rail DC-to-DC converters. Wide input ranges of 9.5 to 18VDC and 18 to 75VDC allow these models to be operated from all popular DC supply voltage systems. With tightly regulated output voltage these DC/DC converters provide a reliable power source for sensitive loads in industrial process controls, factory automation and other equipment exposed to a critical industrial environment. They can be used to isolate a specific load from the 24 volt bus voltage, and offer easy installation with snap-on mounting on DIN rails and detachable screw terminal block. Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks PSP12-DC24-2 PSP24-DC12-1 Features Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies PSP24-DC24-1 Input Voltage Range Input Startup Power (no load) Voltage 9.5 – 18.0 VDC 18 – 75 VDC 1.0 W. max Transformers and Filters Tools Undervoltage Efficiency Shut-down (Typical) 8.4 VDC 7.6 VDC 17.2 VDC 15.7 VDC Test Equipment Enclosures Enclosure Climate Control 86% Safety: Electrical Components Safety: Protective Wear Output Specifications PSP24-DC12-1 PSP05-DC24-5 PSP12-DC24-2 PSP24-DC24-1 DC Converters Circuit Protection Input Specifications Part Number Cable Ties Flexible Cord PSP05-DC24-5 PSP24-DC12-1 PSP05-DC24-5 PSP12-DC24-2 PSP24-DC24-1 Wiring Duct Wire • Ultra-wide input voltage range • Output voltage adjustable • Overload and short circuit protection • Low ripple and noise • I/O-isolation 1500 VDC • Compact, slim plastic case • Reliable snap-on mount on 35mm DIN rail • Wall-mount bracket included • 3-year warranty Part Number Panel Interface Connectors Price $78.00 $79.00 Output Output Ripple/ Output Overvoltage Short MTBF Output Voltage Voltage Protection, Circuit (IEC 1709 Voltage Adj. Range Current Noise (Max.) Regulation* Trigger Point Protection @ 25°C) 24 VDC 24.0 - 28.0 VDC 5 VDC 1A 5.0 - 5.25 VDC 5A $79.00 12 VDC 12.0 - 15.0 VDC 2A $75.00 24 VDC 24.0 - 28.0 VDC 1A <42 V <50mV peak to peak ±0.5 % max <6.5 V <24 V Current limited at 110% typical 2.5 million hours <42 V *Note: Input variation Vin min to Vin max and load variation 0 to 100% Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-59 Terms and Conditions RHINO DC to DC Converters Prices as of April 16, 2014. Check Web site for most current prices. General Specifications Temperature: Operating Storage (non-operating) Derating Humidity (Non-condensing) Temperature Coefficient Switching Frequency Isolation Voltage (1 min.) – Input/Output Reliability, Calculated MTBF @ 25°C Safety Standards Electromagnetic Compatibility (EMC), Emissions Electromagnetic Compatibility (EMC), Immunity Parallel Operation Safety Class Enclosure Rating Enclosure Material Mounting Agency Approvals UL Approval CB Report -10°C to 70°C max (14°F to 158°F max) -25°C to 85°C max, (-13°F to 185°F max) 1.5%/K above 50°C (122°F) 95 % relative humidity max. 0.02 %/K 55 – 180 kHz depending on load (frequency modulation) 1500 VDC >2.5 Mio h (according to IEC-1709) IEC 60950-1, EN 60950-1 (output SELV), UL/cUL 60950-1, EN 60204 EN 61000-6-3 EN 61000-6-2 No parallel operation Degree of protection class 1 IP 20 (IEC 60529) Plastic FR2010-110C (UL 94V-0 rated) DIN rails per EN 50022-35x15/7.5 (snap-on with self-locking spring) bracket for wall/chassis mount included UL/cUL 508 Listed, File E197592, CE Note: All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. Dimensions Input Output 1 Ground 1 +Vout 2 -Vin 2 -Vout 3 +Vin The unit can be mounted on a chassis or wall using the included mounting bracket. Book 3 (14.1) ePW-60 Power Supplies 1 - 80 0 - 633 - 0405 RHINO DC to DC Isolated Converter Prices as of April 16, 2014. Check Web site for most current prices. This isolated DC to DC power supply is used for eliminating ground loops or addressing isolation issues when interfacing to PLC analog I/O modules. The design features handle many types of configuration problems. The FA-DCDC-1 is a DIN-rail mount, ±10VDC, ±5VDC isolated power supply, with each output rated at 125mA. The ±10V and ± 5V outputs are fixed at 1.0% regulation. The input voltage range is 12-24V DC ±15% at approximately 6.7 Watts. Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories ZIPLink Connection System FA-DCDC-1 $64.00 Multi-wire Connectors Sensor Cables and Connectors FA-DCDC-1 General Specifications1 Input Voltage Range Input Power 2 Output Voltage 3 (25°C) Output Current Output Ripple Line Regulation 4 Load Regulation 5 Isolation Inrush Current (50ms) Holdup Time (all channels) Overshoot Protection Input Protection (reverse DC input voltage) Overload Protection Output Protection Peak Line Transient Voltage Operating Temperature Storage Temperature Enclosure Mounting Connection Relative Humidity Environmental Air Vibration Shock Noise Immunity Agency Standards and Approvals M12 Junction Blocks 12V to 24VDC ± 15% 6.7 Watts, Vin 27.6V, 125mA load each channel +5V ±1%, 125mA load,-5V ±1% 125mA load +10V ±1% 125mA load,-10V ±1% 125mA load 125mA (per output voltage) ±5V channels: <10mV peak to peak, Vin 10.2V 125mA load on both channels ±10V channels: <25mV peak to peak, Vin 10.2V, 125mA load on both channels ±5V channels: <10mV, Vin 10.2V to 27.6V, 125mA load on both channels ±10V channels: <20mV, Vin 10.2V to 27.6V, 125mA load on both channels ±5V channels: <20mV, Vin 10.2V, 0 - 125mA load variation ±10V channels: <40mV, Vin 10.2V, 0 - 125mA load variation Input to Output: 1500V; ±5V to ±10V: 1500V 970mA, Vin 10.2V, 125mA load all channels 30mS minimum, Vin 10V, 125mA load all channels No overshoot - Turn on and turn off of Vin Up to -50V reverse. ± Vin reverse polarity connection. Auto shutdown. Short circuit. Cycle Vin post event Indefinite duration. ±5V tied to ±10V 100V for 10mS. Voltage spike on input 0 to 60°C (32 to 140°F) full rated -20 to 70°C (-4 to 158°F) Clear Lexan 221-111 with UN5016 transparent blue colorant 35mm wide DIN rail: part # DN-R35S1 or DN-35HS1; surface mount 5mm screw terminal 5 to 90% (non-condensing) No corrosive gases permitted MIL STD 810C 514.2 MIL STD 810C 516.2 NEMA ICS3-304 UL/cUL listed, UL file E200031, UL508/CSA - C22.2 No. 142-M1987 for ordinary locations. Class I, Division 2, Groups A, B, C, D Hazardous Locations Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Notes: 1. All specifications are over the full operating temperature range (0°C to 60°C) unless stated otherwise. 2. “Channel” means Output Voltage. For example: +5V is one channel and -10V is another. 3. All output voltage channels are independent of each other. Changing loading on one will have no effect on the other voltage outputs. 4. LINE Regulation: varying the Input Voltage over entire range (12V to 24V ± 15%) and the resultant change in the Output Voltage(s) under worst case load conditions (all output channels drawing 125mA). 5. LOAD Regulation: varying the output loads from no-load to a worst case 125mA load and measuring the resultant change in the Output Voltage(s) under a worst case minimum Input Voltage (10.2V) condition. "B" V+ Com 10-30 Volt Controller ± 5 Volt Regulator +5 Com2 -5 " C" ± 10 Volt Regulator +10 Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions 12-24 V o lt *internal diagram Enclosures Com1 -10 "A" Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Power Supplies ePW-61 RHINO DC to DC Isolated Converter Prices as of April 16, 2014. Check Web site for most current prices. Applications Wetting Resistive Device Isolated Module Power Supply ANALOG 4CH IN ANALOG 2CH +10V Com1 0V 0V +24V +V CH1-- COM Resistive Device 0 - 1 0V FA-DCDC-1 FA-DCDC-1 18--30VDC 80mA ANALOG IN 0--5VDC - 5--+5VDC 0V +25V +V 0V1 +V1 +V CH1-V COM CH1+ * output in mV N/C CH2+ N/C CH3-- 0V2 CH3+ +V2 CH4-+ 5V CH4+ 0--10VDC - 10--+10VDC Com2 CH2-V (Fig. 2) F 2--04AD--2 (Fig. 3) CH2+V F 2--02DAS --2 When using a linear potentiometer, the +10V connects to the high side of the potentiometer and the COM1 becomes the zero volt reference. The wiper connects to the analog input. The result is 0 to 10V at the analog module input. (Fig. 1) TEMP VOLT F 2--04THM COM CH1+V CH2-- (Fig. 1) Load Cell - 10V F 2--04AD--2 Wiper IN COM1 +10V + 10 V +V Load Cell Application OUT FA-DCDC-1 FA-DCDC -1 CH1+ CH1 CH2+ CH2 CH3+ CH3 CH4+ CH4 +24V 0V Note: F2-04THM must be set for proper voltage range. Use in a solar/battery application where unregulated 12VDC is available and the analog module requires 24VDC for operation, connect the +10V to +24V module power, connect the -10V to the +5V and the COM2 to the 0V module power. (Fig. 2) Use to power a load cell application. (Fig. 3) THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, DIVISION 2/ZONE 2, GROUPS A, B, C AND D NON-HAZARDOUS LOCATIONS ONLY. WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2/ZONE 2. WARNING - EXPLOSION HAZARD - DO NOT CONNECT OR DISCONNECT CONNECTORS OR OPERATE SWITCHES WHILE CIRCUIT IS LIVE UNLESS THE AREA IS KNOWN TO BE NON HAZARDOUS. Dimensions, in(mm) Dia. 0.24 (6.2) Dia. 0.24 [6.2] (2) FA-DCDC-1 +10 +10V 125mA COM1 COM1 -10 -10V 125mA A FA-DCDC-1 DC DC CONVERTER ± 5VDC ISOLATED ± 10VDC ISOLATED 12-24V DC V+ COM 4.06 [103.0] 4.53 [115.0] 12-24VDC ±15% 3.07 [77.9] COM B +5 +5V 125mA COM2 COM2 -5 -5V C 125mA 4.34 [110.1] 0.91 [23.0] 4.67 [118.6] Book 3 (14.1) ePW-62 Power Supplies 1 - 80 0 - 633 - 0405 Power Supplies: Open Frame Prices as of April 16, 2014. Check Web site for most current prices. The most economical choice for 24 VDC power FA-24PS These power supplies are especially useful when an inexpensive external supply is required. $44.50 The FA-24PS compact switching power supply accepts 100-240 VAC or DC input and provides up to 1.25A (30 watts) output current at 24 VDC. Company Information Terminal Blocks Power Distribution Blocks FA-24PS-90 Wiring Accessories $62.00 ZIPLink Connection System Multi-wire Connectors The FA-24PS-90 supplies 3.7A (90 watts) at 24 VDC and its input is jumper selectable between 95-130 or 190-264 VAC. L Sensor Cables and Connectors M12 Junction Blocks AC Terminals L N Jumper for 95-130 VAC input N Panel Interface Connectors Wiring Duct 3.7” (94mm) DC Terminals (24VDC) 3.7” (94mm) Cable Ties Wire Flexible Cord - + DC Terminals (24VDC) Multi-conductor Flex Cable - + 2.5” (63.5mm) 3.0” (76.2mm) 3.5” (89mm) Wire Management Products Power Supplies 4.9” (124.5mm) DC Converters Transformers and Filters General Specifications Part Number FA-24PS FA-24PS-90 Input Voltage Range 100-240 VAC/DC 95-130 VAC or 190-264 VAC, jumper selectable Input Voltage Frequency 47 to 63 Hz 47 to 63 Hz Input Power 40 VA 112 VA Output Voltage 24 VDC ±5% 24 VDC ±5% Output Current 1.25 A maximum continuous 3.7 A maximum continuous, subject to derating Output Ripple ± 200 mV maximum ± 200 mV maximum Temperature Rating 0°C to 60°C full rated Circuit Protection Tools Test Equipment Enclosures Transient Response 0°C to 30°C full rated; derate current 1.1% per degree above 30°C; 60°C max Output stays within 1% for a load current change from 75% (0.9A) to Output stays within 1% for a load current change from 75% (2.8A) to either 50% (0.6A) or 100% (1.25A) either 50% (1.8A) or 100% (3.7A) Mounting DIN rail, 35mm wide; Models DN-R35S1 or DN-R35HS1 DIN rail, 35mm wide; Models DN-R35S1 or DN-R35HS1 Screw Terminals Wire Size: 18-12 AWG Rec. Screw Torque: 4.4 in•lb or 0.5 Nm Wire Size: 18-12 AWG Rec. Screw Torque: 4.4 in•lb or 0.5 Nm Insulation Resistance 10 M at 500 V minimum 10 M at 500 V minimum Dielectric Withstand Voltage L or N Input to Output: 500 V min; Ground Input to Output: 250 V min L or N Input to Output: 500 V min; Ground Input to Output: 250 V min Brown-out Protection Provides temporary regulation down to 85 VAC at full load Provides temporary regulation at 95VAC at full load Input Protection Overload Protection The power supply has an internal fuse for the AC input line, rated at 3.15 amps; not user replaceable; external input fusing required. Protects power supply from overload and short circuit conditions. Includes automatic recovery upon removal of the overload condition The power supply has an internal fuse for the AC input line, rated at 3.15 amps; not user replaceable; external input fusing required. Protects power supply from overload and short circuit conditions. Includes automatic recovery upon removal of the overload condition Inrush Current (2mS) 115 V <12.5 A / 230 VAC <13.9 A 115 VAC <79 A / 230 VAC <37 A Overshoot Protection No overshoot on turn-on or turn-off No overshoot on turn-on or turn-off Agency Standards and Approvals UL 508; Class I, Div 2, Groups A, B, C, D hazardous locations; CUL, UL Listed File E200031 Book 3 (14.1) w w w . a u t o m a t i o n d i r e c t . c o m / d c - p o w e r- s u p p l i e s Data Cables Power Supplies ePW-63 Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Build your panel for less with AutomationDirect Metal, Non-Metallic and Disconnect Enclosures We’ve got what you need to build your control panel. With direct prices, fast shipping and free tech support, you can count on us for the best value in automation. We’ve lowered the price of every enclosure we sell to help your budget even more! Choose from over 1,600 Hubbell/Wiegmann enclosures across NEMA 1, 3S, 3R, 4, 4X, 6P, 12, 4/12, and 13 ratings, all at prices well below more traditional suppliers. CHECK OUT OUR PRICES ON ENCLOSURES Heat Exchangers for NEMA / UL Type 4 & 4X enclosures Maintains optimum enclosure temperature in harsh environments • • • • • • • 22 to 70 Watts/degree F Heat pipe technology Closed loop design Low operating cost and low maintenance Easy to mount on only one side of your enclosure (QHUJ\HèFLHQWXVHVQRPRUH SRZHUWKDQDoOWHUHGIDQV\VWHP )LOWHUIUHHQRGLPLQLVKHG cooling capacity AutomationDirect Enclosures and Accessories Hubbell/Wiegmann or Stratus Price/Part Number Hoffman Price/Part Number NEMA 1 wall mount 24 x 24 x 08” $177.00 $338.80 NEMA 12 wall mount 20 x 16 x 08” $240.00 N12201608 $424.70 A-201608LP Air Conditioner for NEMA 12 Type Enclosures 2,000 BTU $1,778.00 $3,421.63 NEMA 4X wall mount 20 x 20 x 06” $731.00 SSN4202006 $1,355.61 A-20H2006SSLP N1C242408LP A-24N24BLP TA10-020-26-04 T200226G100 *All prices are U.S. published prices. AutomationDirect prices from April 2014 Price List. Hoffman prices are taken from www.newark.com 2/20/2014. Prices may vary by dealer. Many other part numbers are available from all vendors. Starting at only $1028 (TE20-015-17-04) Research, price, buy at: www.automationdirect.com/enclosures www.automationdirect.com/ enclosure-cooling Also Available Enclosure Climate Control and Lighting Wire and Connectors Hazardous Location Control Stations Order Today, Ships Today! * See our Web site for details and restrictions. © Copyright 2014 AutomationDirect, Cumming, GA USA. All rights reserved. Terminal Blocks and Accessories Pushbuttons and Lights 1-800-633-0405 Wire Duct and Wire Management Screwdrivers and Torque Tools the #1 value in automation Prices as of April 16, 2014. Check Web site for most current prices. Company Information Terminal Blocks Transformers Power Distribution Blocks Table of Contents Transformers and Filters Overview Wiring Accessories TX-2 ZIPLink Connection System Hammond Transformers TX-3 Overview TX-3 HPS Series Control Transformer Selection Guide TX-3 480x240 / 240x120 VAC Control Transformers TX-5 380x277x208 / 240x120 VAC Control Transformers TX-7 240x120 / 24x12 VAC Control Transformers TX-9 480x240 / 120x25 VAC Control Transformers TX-11 Accessories TX-13 Recommendations for Overcurrent Protection UL and CSA (North American) Standards TX-14 Fortress Series Commercial Encapsulated Transformers TX-17 Primary 480 x 240 VAC, Secondary 240 x 120 VAC TX-18 Primary 277/240/208/120 VAC, Secondary 240 x 120 VAC TX-21 Primary 480**/440/416/400/380 x 240**/220/208/200/190VAC, Secondary 240 x 120 VAC TX-24 Jefferson Electric Buck-Boost Transformers TX-27 Overview TX-27 Selection Information and Charts TX-30 Wiring Diagrams TX-34 General Specifications and Terminations TX-35 Dimensional Diagrams TX-37 Buck-Boost Transformer Cross-reference TX-38 Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Cutler-Hammer Powerline Filters TX-39 Wire Management Products Convenience Outlet TX-40 Power Supplies Up-to-date price list: DC Converters www.automationdirect.com/pricelist Transformers and Filters FREE Technical Support: Circuit Protection www.automationdirect.com/support Tools FREE Videos: Test Equipment www.automationdirect.com/videos Enclosures FREE Documentation: www.automationdirect.com/documentation Enclosure Climate Control FREE CAD drawings: Safety: Electrical Components www.automationdirect.com/cad Safety: Protective Wear Terms and Conditions Book 3 (14.1) www.automationdirect.com/power-transformers Transformers eTX-1 Prices as of April 16, 2014. Check Web site for most current prices. Transformers HPS Fortress™ Encapsulated Transformers starting at $96.00 Hammond encapsulated power transformers are manufactured with electrical grade silica sand and resin compounds, which completely enclose the core and coil to seal out moisture, airborne contaminants and eliminates corrosion and deterioration. •Industry standard sizes •Easy installation and hook-up, wall mounting •10 year warranty - superior quality in materials and workmanship •NEMA 3R rated commercial wall-mounted encapsulated transformer •Sizes range from 100VA to 25kVA •Input voltage ranges - 208 to 480 VAC •Output voltages of 240 and 120 VAC HPS Imperator™ Compact Control Transformers starting at $40.00 HPS Imperator control transformers from Hammond are specifically designed for high inrush applications requiring reliable output voltage stability. This series comes with a lifetime warranty; secondary fuse kit is included. Four series of compact control transformers are available: MQMJ Series - 480x240 VAC to 240x120 VAC PG Series - 240x120 VAC to 24x12 VAC MGJ Series - 380x277x208 VAC to 240x120 VAC MLI Series - 480x240 VAC to 120x25 VAC Jefferson Electric Buck-Boost Transformers starting at $53.00 Buck-boost transformers are designed to maximize the performance and life of electrical equipment. They are typically used to power loads with specific voltage requirements that differ from the available line voltage. •Ratings: Single phase from 50VA to 2kVA; •NEMA 3R rated commercial wall-mounted 60 Hz encapsulated transformer •Encapsulated with electrical grade resin •10-year limited warranty (limited to mfg. defects) •Cores of high-quality electrical steel •Aluminum/copper windings AEGIS Powerline Filters Convenience Outlet • 15 amp rated, NEMA 5 -15 R • DIN rail mounting • UL 508 listed • Compact design • DIN rail included 35mm • Meets latest UL safety standards for SPD (surge protective device) and EMI filtering protection • Contains no replaceable parts or items that require periodic maintenance • 10-year warranty • UL1449 3rd Ed – Type 2 SPD Book 3 (14.1) eTX-2 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. Hammond Transformers Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Get years of reliable service from a quality transformer at a practical price HPS Imperator control transformers for industrial applications tm HPS Imperator control transformers from Hammond are specifically designed for high inrush applications requiring reliable output voltage stability. Designed to meet industrial applications where electromagnetic devices such as relays, solenoids, etc. are used, they maximize inrush capability and output voltage regulation when electromagnetic devices are initially energized. HPS Imperator control transformers use Mylar, Nomex and other high-quality insulating materials. Insulation is used to electrically insulate turn-to-turn windings, layer-to-layer windings, primary-to-secondary windings and ground. These transformers are vacuum impregnated with VT polyester resin and oven-cured, which seals the surface and eliminates moisture. Filling the entire unit provides a strong mechanical bond and offers protection from the environment. This design utilizes superior insulation systems and is constructed with high quality silicon steel laminations, which provide optimum performance and reliability. The custom injection-molded cover, with its unique fin-shaped design, provides excellent cooling properties while protecting the coils and terminations from moisture, dirt and other industrial airborne contaminants. The heavy steel mounting feet are welded to the core, providing maximum strength and low noise in a compact design. The HPS imperator’s unique terminal block design (patent pending) allows for the quick and easy installation of standard secondary or optional primary 13/32” x 1 1/2” midget/type CC fuse clips on every unit. This is the simplest and most inexpensive fusing installation provided on any industrial control transformer in the market today. The windings and internal terminations of the HPS Imperator are encapsulated, which protects them from moisture, dirt and other airborne contaminants. The custom molded coil covers with their unique ‘fin shaped’ design combine superior transformer cooling properties with a clean bold look. The HPS Imperator utilizes custom serrated terminals, in combination with standard SEMS washer screws making assembly easier and quicker to install; and provides superior connection strength when connecting with bare, solid, or stranded wire. It also allows for ring or spade termination connectors. HPS Fortress tm commercial potted transformers The HPS Fortress commercial potted transformers provide an innovative design with commercial applications where quality, ease of installation, and low cost are key. All Fortress units are encapsulated with electrical grade silica sand and resin compounds, which completely enclose the core and coil to seal out moisture, airborne contaminants and eliminates corrosion and deterioration. Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Superior quality and value • Compact, efficient design • Easy installation and hook-up • I nexpensive while maintaining superior quality in materials and workmanship • W all mounting Applications Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components • S hopping centers • S chools • S ports complexes • O ffice buildings • L ighting Safety: Protective Wear Terms and Conditions Book 3 (14.1) www.automationdirect.com/power-transformers Cable Ties Transformers eTX-3 Prices as of April 16, 2014. Check Web site for most current prices. Control Transformer Selection Control transformer selection To select the proper transformer, you must first determine three characteristics of the load circuit. They are: total steady-state (sealed) VA, total inrush VA, and inrush load power factor. Total steady-state “sealed” VA is the total amount of VA that the transformer must supply to the load circuit for an extended length of time. Calculate by adding the total steady-state VA of all devices in your control circuit. (The operating VA data for the devices should be available from the manufacturers.) The inrush VA is the amount of VA that the transformer must supply for all components in the control circuit that are energized together. Consideration for the start-up sequence may be required. (Inrush VA data should be obtained from the device manufacturers.) The inrush load power factor is difficult to determine without detailed vector analysis of all the control components. In the absence of such information, we recommend that a 40% power factor be utilized. Six easy steps Once the three load circuit variables have been determined, follow these steps to select the proper transformer. 1. D etermine your primary (supply) and secondary (output) voltage requirements, as well as the required frequency (i.e. 60 Hz). 2. Calculate the total sealed VA of your circuit by adding the total sealed VA of all devices in the control circuit. 3. C alculate the inrush VA by adding the inrush VA of all components being energized together. Remember to add the sealed VA of all components that do not have inrush VA (lamps, timers, etc.), as they do present a load to the transformer during maximum inrush. If the inrush for your components is unknown, assume a 40% inrush power factor. 4. Calculate the total inrush VA using one of two methods: Method B will result in slightly larger transformer selected. A or B 5. I f the nominal supply voltage does not fluctuate more than 5%, then reference the 90% secondary voltage column in the Regulation Data Table for the correct VA rating. If the supply voltage varies up to 10%, the 95% secondary voltage column should be used to size the transformer. The 85% secondary voltage column gives minimum values for proper electromagnetic device operation and should only be used as a reference. 6. U sing the regulation data table below, select the appropriate VA rated transformer: A. W ith a continuous VA rating that is equal to or greater than the value in Step 2. B. W ith a maximum inrush VA equal to or greater than the value obtained in Step 4. Note: S ee over-current protection chart for transformers at the end of this section. HPS Imperator Transformer Regulation Data Table Inrush VA @ 40% Power Factor Continuous VA Transformer 85% Secondary 90% Secondary 95% Secondary Nameplate Voltage Voltage Voltage 50 330 259 192 75 350 258 170 100 620 467 321 512 150 895 699 250 1596 1229 880 350 2464 1889 1345 500 3939 2854 1819 750 6422 4778 3228 1000 9842 7102 4530 1500 12797 9018 5489 Note: It is recommended that a control transformer be sized at a 40% power factor. Some components in a circuit, such as electromagnetic devices, typically operate at that level due to their inherently lower power factor. Selecting a transformer at 40% power factor will more than adequately size the unit for all the various loads in the circuit. Voltage regulation in transformers is the difference between the “No-Load voltage” and the “Full-Load voltage”. This is expressed in terms of percentage. Regulation = Percentage ENo-Load - EFull Load EFull Load (100%) The secondary voltage (nominal) listed in these pages are at Full-Load, meaning the point at which the transformer is operating at maximum permissible secondary current. No-Load voltage can increase 4 to 6%. Warning: Secondary voltages of transformers may damage some loads. For example, a transformer connected as 480/120 Volt but applied 495 Volt primary can produce at No-Load a voltage of 134 Volts which will damage the inputs of a PLC D0-06AA, whose maximum input voltage is 132 Volt. Notice that the current of D0-06AA input is 10mA, making it very close to No-Load. Book 3 (14.1) eTX-4 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. HPS Imperator™ 480x240 / 240x120 VAC Control Transformers Specifications Features • 6 00V class, machine tool rated industrial control transformers • 5 0/60 Hertz • VA range from 50 VA up to 1500 VA •C onstructed with high quality silicon steel laminations that provide optimum performance and reliability • E ncapsulated coils, encased in a custom injection molded cover, protect coils and terminations from moisture, dirt and other industrial airborne contaminants. • T emperature Range: -20°C (-4°F) to 40°C (104°F) • Terminated with #8/32 slot/Phillips terminal screws complete with SEMS washer (suitable for 18 AWG to 14 AWG solid or 14 AWG stranded wire) • Insulation system: • 50 - 150VA, temperature rise 55°C (131°F), insulation class 105°C (221°F), • 250 - 1500VA, temperature rise 80°C (176°F), insulation class 130°C (266°F) • SEMS (standard machine screw with lock washer) standard • Standard secondary fuse kits utilizing 13/32” x 1 ½” fuse clips included with all transformers. Fuses are not included. (See Edison fuse section for MEN fuses.) • Optional primary fuse kits available utilizing 13/32” x 1 ½” fuse clips (See Edison fuse section for HCTR fuses.) • Optional finger-safe terminal covers • LIFETIME warranty (limited to mfg defects) Agency Approvals • UL Listed (approved for U.S. and Canada) File E50394 • CE Mark standard on all units • RoHS Compliant Part Number Price PH50MQMJ PH75MQMJ PH100MQMJ PH150MQMJ PH250MQMJ PH350MQMJ PH500MQMJ PH750MQMJ PH1000MQMJ PH1500MQMJ $40.00 $43.00 $50.00 $62.00 $79.00 $92.00 $116.00 $157.00 $172.00 $229.00 50 75 100 150 250 350 500 750 1000 1500 Mtg. Fig. A A A B B B B B B B Primary Voltage (50/60Hz) 240x480 230x460 220x440 Secondary Voltage (Nominal) Output Current (Amps) 120/240 Impedance % VA 120x240 115x230 110x220 0.42/0.21 0.63/0.31 0.83/0.42 1.25/0.63 2.08/1.04 2.92/1.46 4.17/2.08 6.25/3.13 8.33/4.17 12.5/6.25 50 75 100 150 250 350 500 750 1000 1500 %z Total Heat Dissipation (Watts)** Weight (lb) 8.3 8.7 8.4 8.0 7.8 7.0 5.0 4.9 3.9 3.9 11 14 14 18 29 33 40 54 69 101 3.50 3.54 4.50 5.70 7.50 10.1 14.2 16.6 23.6 34.0 Note: *VA capacity rated at the output of the transformer. ** Heat dissipation calculated based on full rated load on transformer. Dimensions Terminal Blocks Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors HPS Imperator 480x240/240x120 Control Transformer Specifications Volt-Amp Rating* Company Information Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters B B Transformers and Filters Circuit Protection Tools C GxH C GxH Test Equipment Enclosures A D E FIGURE A A E D Enclosure Climate Control FIGURE B (150VA to 1500VA) (100VA and less) Safety: Electrical Components HPS Imperator 480x240/240x120 Control Transformer Dimensions Part Number PH50MQMJ PH75MQMJ PH100MQMJ PH150MQMJ PH250MQMJ PH350MQMJ PH500MQMJ PH750MQMJ PH1000MQMJ PH1500MQMJ Mtg. Fig. A A A B B B B B B B Overall Dimensions inches (mm) A B C 3.00 (76.2) 3.25 (82.6) 3.25 (82.6) 4.00 (101.6) 4.50 (114.3) 4.50 (114.3) 4.75 (120.7) 5.13 (130.3) 5.25 (133.4) 5.25 (133.4) 4.38 (111.3) 3.88 (85.9) 4.19 (106.4) 4.94 (125.5) 5.44 (138.2) 5.19 (131.8) 5.94 (150.9) 6.69 (169.9) 6.81 (173.0) 8.19 (208.0) 3.19 (81.0) 3.56 (90.4) 3.63 (92.2) 3.81 (96.8) 3.81 (96.8) 4.44 (112.8) 4.31 (109.5) 4.31 (109.5) 4.94 (125.5) 4.94 (125.5) Mounting Centers inches (mm) D E 2.50 (63.5) 2.63 (66.8) 2.63 (66.8) 3.38 (85.9) 3.75 (95.3) 3.75 (95.3) 4.06 (103.1) 4.38 (111.3) 4.50 (114.3) 4.50 (114.3) 2.25 (57.2) 2.50 (63.5) 2.63 (66.8) 2.75 (69.9) 3.13 (79.5) 3.75 (95.3) 3.81 (96.8) 4.31 (109.5) 4.44 (112.8) 6.06 (153.9) Mounting Slot inches (mm) GxH Height with Finger Guard inches (mm) Depth with Finger Guard inches (mm) 0.22 x 0.44 (5.6 x 11.2) 0.22 x 0.44 (5.6 x 11.2) 0.22 x 0.44 (5.6 x 11.2) 0.22 x 0.75 (5.6 x 19.1) 0.22 x 0.75 (5.6 x 19.1) 0.22 x 0.75 (5.6 x 19.1) 0.31 x 0.94 (7.9 x 23.9) 0.31 x 0.81 (7.9 x 20.6) 0.31 x 0.81 (7.9 x 20.6) 0.38 x 1.00 (9.7 x 25.4) 4.00 (101.6) 4.37 (111.0) 4.44 (112.8) 4.31 (109.5) 4.31 (109.5) 4.94 (125.5) 4.81 (122.2) 4.81 (122.2) 5.44 (138.2) 5.44 (138.2) 5.82 (147.8) 5.32 (135.1) 5.63 (143.0) 6.44 (163.6) 6.94 (176.3) 6.69 (169.9) 7.44 (189.0) 8.19 (208.1) 8.31 (211.1) 9.69 (246.1) Note: All dimensions are ±0.06 inches unless otherwise noted. Book 3 (14.1) www.automationdirect.com/power-transformers Transformers eTX-5 Safety: Protective Wear Terms and Conditions Prices as of April 16, 2014. Check Web site for most current prices. HPS Imperator™ 480x240 / 240x120 VAC Control Transformers Wiring Specifications Wiring HV 1 2 3 PH***MQMJ Schematic for 50, 75 and 100VA Units HV 4 1 2 3 4 8 5 1 2 3 3 2 65 (Primary Volts) 240 480 240 480 7 6 High Voltage (HV) 4 230 460 230 460 4 2 3 2 1 4 3 2 LV LV HV HV 3 4 5 2 (Secondary Volts) 1 3 5 7 115 230 115 230 8 3 4 4 3 17 2 5 3 (Primary Volts) 5 230 460 230 460 5 4 3 LV 2 4 1, 4 1, 4 6, 7 6, 7 1-5, 4-8 1-5, 4-8 Install Jumpers/Links Between Lines Load Lines Connect To Install Fuse Clips To 3-4, 1-2 2-3 3-4, 1-2 2-3 1, 4 1, 4 4, 6 4, 6 1-5 1-5 (Secondary Volts) 2 LV 120 240 120 240 115 230 115 230 Install Jumpers/Links Between Lines Supply Lines Connect To Install Fuse Clips To 2-3, 4-5 3-4 2-3, 4-5 3-4 2, 5 2, 5 1, 6 1, 6 2-7, 5-8 2-7, 5-8 Install Jumpers/Links Between Lines Load Lines Connect To Install Fuse Clips To 4-5, 2-3 3-4 4-5, 2-3 3-4 2, 5 2, 5 1, 5 1, 5 2-7 2-7 220 440 220 440 Low Voltage (LV) 5 1-2, 3-4 2-3 1-2, 3-4 2-3 110 220 110 220 High Voltage (HV) 240 480 240 480 6 2 120 240 120 240 Install Fuse Clips To PH***MQMJ Schematic for 150VA to 1500VA Units 4 1 1 Supply Lines Connect To 220 440 220 440 Low Voltage (LV) 4 Install Jumpers/Links Between Lines 110 220 110 220 Notes • FUSES NOT INCLUDED (see Edison fuse section for fuses). • Secondary fuse clips supplied but not installed. Order fuses and primary fuse clips separately. • Jumper links to make primary/secondary series/parallel connections supplied, but not installed. Book 3 (14.1) eTX-6 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. HPS Imperator™ 380x277x208 / 240x120 VAC Control Transformers Specifications Features • Terminated with #8/32 slot/Phillips terminal screws complete with SEMS washer (suitable for 18 AWG to 14 AWG solid or 14 AWG stranded wire) • Insulation system: • 50 - 150VA, temperature rise 55°C (131°F), insulation class 105°C (221°F), • 250 - 500VA, temperature rise 80°C (176°F), insulation class 130°C (266°F) • SEMS (standard machine screw with lock washer) standard • Standard secondary fuse kits utilizing 13/32” x 1 ½” fuse clips included with all transformers. Fuses are not included. (See Edison fuse section for MEN fuses.) • 6 00V class, machine tool rated industrial control transformers • 5 0/60 Hertz • VA range from 50 VA up to 500 VA •C onstructed with high quality silicon steel laminations that provide optimum performance and reliability • E ncapsulated coils, encased in a custom injection molded cover, protect coils and terminations from moisture, dirt and other industrial airborne contaminants. • T emperature Range: -20°C (-4°F) to 40°C (104°F) Company Information Terminal Blocks • Optional primary fuse kits available utilizing 13/32” x 1 ½” fuse clips (See Edison fuse section for HCTR fuses.) • Optional finger-safe terminal covers • LIFETIME warranty (limited to mfg. defects) Agency Approvals • UL Listed (approved for U.S. and Canada) File E50394 • CE Mark standard on all units • RoHS Compliant Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors HPS Imperator 380x277x208/240x120 Control Transformer Specifications Part Number Price Volt-Amp Rating* Mtg. Fig. PH50MGJ PH75MGJ PH100MGJ PH150MGJ PH250MGJ PH350MGJ PH500MGJ $46.00 $47.00 $52.00 $69.00 $97.00 $116.00 50 75 100 150 250 350 A A A B B B $149.00 500 B Primary Voltage (50/60Hz) Output Current (Amps) 120/240 Secondary Voltage (Nominal) 208x277x380 120x240 Impedance % Wiring Duct VA %z Total Heat Dissipation (Watts)** 0.42/0.21 0.63/0.31 0.83/0.42 1.25/0.63 2.08/1.04 2.92/1.46 50 75 100 150 250 350 8.3 8.7 8.4 8.0 7.8 7.0 11 14 14 18 29 33 3.5 4.5 5.2 7.6 8.3 11.0 4.17/2.08 500 5.0 40 16.3 Weight (lb) Cable Ties Wire Note: *VA capacity rated at the output of the transformer. ** Heat dissipation calculated based on full rated load on transformer. Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies Dimensions B DC Converters Transformers and Filters B Circuit Protection C GxH C GxH Tools Test Equipment Enclosures A D E FIGURE A A Enclosure Climate Control E D (100VA and less) FIGURE B (150VA to 500VA) Safety: Protective Wear HPS Imperator 380x277x208/240x120 Control Transformer Dimensions Part Number Mtg. Fig. PH50MGJ PH75MGJ PH100MGJ PH150MGJ PH250MGJ PH350MGJ PH500MGJ A A A B B B B Overall Dimensions inches (mm) Mounting Centers inches (mm) Mounting Slot inches (mm) A B C D E GXH 3.25 (82.6) 3.25 (82.6) 3.25 (82.6) 4.00 (101.6) 4.50 (114.3) 4.50 (114.3) 4.75 (120.7) 3.88 (98.6) 4.19 (106.4) 4.69 (119.1) 5.44 (138.2) 4.88 (124.0) 5.56 (141.2) 6.69 (169.9) 3.56 (90.4) 3.63 (92.2) 3.63 (92.2) 3.81 (96.8) 4.44 (112.8) 4.44 (112.8) 4.31 (109.5) 2.63 (66.8) 2.63 (66.8) 2.63 (66.8) 3.38 (85.9) 3.75 (95.3) 3.75 (95.3) 4.06 (103.1) 2.50 (63.5) 2.63 (66.8) 2.63 (66.8) 2.75 (69.9) 3.75 (95.3) 3.75 (95.3) 4.50 (114.3) 0.22 x 0.44 (5.6 x 11.2) 0.22 x 0.44 (5.6 x 11.2) 0.22 x 0.44 (5.6 x 11.2) 0.22 x 0.75 (5.6 x 19.1) 0.22 x 0.75 (5.6 x 19.1) 0.22 x 0.75 (5.6 x 19.1) 0.31 x 0.94 (7.9 x 23.9) Height with Finger Guard, inches (mm) Depth with Finger Guard inches (mm) 4.37 (111.0) 4.44 (112.8) 4.44 (112.8) 4.50 (114.3) 4.94 (125.5) 4.94 (125.5) 4.81 (122.2) 5.32 (135.1) 5.63 (143.0) 6.13 (155.7) 6.94 (176.3) 6.38 (162.1) 7.06 (179.3) 8.19 (208.0) Note: All dimensions are ±0.06 inches unless otherwise noted. Book 3 (14.1) www.automationdirect.com/power-transformers Transformers Safety: Electrical Components eTX-7 Terms and Conditions Prices as of April 16, 2014. Check Web site for most current prices. HPS Imperator™ 380x277x208 / 240x120 VAC Control Transformers Wiring Specifications Wiring PH***MGJ Schematic for 50, 75 and 100VA Units HV 6 5 1 4 Dotted line represents supplied jumper lead. 4 2 Supply Lines Connect To Install Fuse Clips To 380 277 208 380 277 208 None None None 3-8 8-7 2-8 1, 3 1, 7 1, 2 6, 4 6, 4 6, 4 Unfused Unfused Unfused 1-5, 4-8 1-5, 4-8 1-5, 4-8 Low Voltage (LV) (Secondary Volts) Install Supplied Links Between Terminals Load Lines Connect To Install Fuse Clips To 120 240 120 240 3-4, 1-2 2-3 3-4, 1-2 2-3 1, 4 1, 4 4, 6 4, 6 Unfused Unfused 1-5 1-5 3 2 2 65 1 120V Install Supplied Jumpers Between Terminals 7 3 3 (Primary Volts) 8 380V 277V 208V 4 High Voltage (HV) 4 1 3 2 1 240V LV PH***MGJ Schematic for 150VA to 1000VA Units HV 1 5 Dotted line represents supplied jumper lead. 7 2 380V 277V 208V 6 5 4 Install Supplied Jumpers Between Terminals Supply Lines Connect To Install Fuse Clips To 380 277 208 380 277 208 None None None 8-6 4-8 3-8 2, 6 2, 4 2, 3 1, 5 1, 5 1, 5 Unfused Unfused Unfused 2-7, 5-8 2-7, 5-8 2-7, 5-8 Low Voltage (LV) (Secondary Volts) Install Supplied Links Between Terminals Load Lines Connect To Install Fuse Clips To 120 240 120 240 4-5, 2-3 3-4 4-5, 2-3 3-4 2, 5 2, 5 1, 5 1, 5 Unfused Unfused 2-7 2-7 8 6 3 3 17 3 2 1 120V (Primary Volts) 4 4 5 High Voltage (HV) 2 6 5 4 3 2 1 240V LV Notes • FUSES NOT INCLUDED (see Edison fuse section for fuses). • Secondary fuse clips supplied but not installed. Order fuses and primary fuse clips separately. • Jumper links to make primary/secondary series/parallel connections supplied, but not installed. Book 3 (14.1) eTX-8 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. HPS Imperator™ 240x120 / 24x12 VAC Control Transformers Specifications Features • Terminated with #8/32 slot/Phillips terminal screws complete with SEMS washer (suitable for 18 AWG to 14 AWG solid or 14 AWG stranded wire, not on PH750PG or PH1000PG). A ring or spade connector must be used on larger size wire. • Insulation system: • 50 - 150VA, temperature rise 55°C (131°F), insulation class 105°C (221°F), • 250 - 1000VA, temperature rise 80°C (176°F), insulation class 130°C (266°F) • Standard secondary fuse kits utilizing 13/32” x 1 ½” CC fuse clips included with all transformers. Fuses are not included. (See Edison fuse section for MEN Midget fuses.) • 6 00V class, machine tool rated industrial control transformers • 5 0/60 Hertz • VA range from 50 VA up to 1000 VA •C onstructed with high quality silicon steel laminations that provide optimum performance and reliability • E ncapsulated coils, encased in a custom injection molded cover, protect coils and terminations from moisture, dirt and other industrial airborne contaminants. • T emperature Range: -20°C (-4°F) to 40°C (104°F) Company Information Terminal Blocks • Optional primary fuse kits available utilizing 13/32” x 1 ½” fuse clips (See Edison fuse section for HCTR fuses.) • Optional finger-safe terminal covers • LIFETIME warranty (limited to mfg. defects) Agency Approvals • UL Listed (approved for U.S. and Canada) File E50394 • CE Mark standard on all units • RoHS Compliant Part Number Price Volt-Amp Rating* Mtg. Fig. PH50PG PH75PG PH100PG PH150PG PH250PG PH350PG PH500PG PH750PG*** PH1000PG*** $40.00 $41.00 $46.00 $62.00 $79.00 $92.00 $116.00 $156.00 50 75 100 150 250 350 500 750 A A A B B B B B $175.00 1000 B 120x240 115x230 110x220 Secondary Voltage (Nominal) Output Current (Amps) 12/24 12x24 11.5x23 11x22 Impedance % ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Wiring Duct VA %z Total Heat Dissipation (Watts)** 4.17/2.08 6.25/3.13 8.33/4.17 12.5/6.25 20.8/10.4 29.2/14.6 41.7/20.8 62.5/31.3 50 75 100 150 250 350 500 750 8.3 8.7 8.4 8.0 7.8 7.0 5.0 4.9 11 14 14 18 29 33 40 54 3.5 3.5 4.5 5.7 7.5 10.1 14.2 16.6 83.3/41.7 1000 3.9 69 23.6 Weight (lb) Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies Note: *VA capacity rated at the output of the transformer. ** Heat dissipation calculated based on full rated load on transformer. *** Terminated with 1/4-20 screw on secondary side to accept ring terminal connector Dimensions Wiring Accessories Panel Interface Connectors HPS Imperator 240x120/24x12 Control Transformer Specifications Primary Voltage (50/60Hz) Power Distribution Blocks DC Converters B Transformers and Filters B Circuit Protection C GxH Tools C GxH Test Equipment Enclosures A D E A E D Enclosure Climate Control Safety: Electrical Components FIGURE B (150VA to 1000VA) FIGURE A(100VA and less) HPS Imperator 240x120/24x12 Control Transformer Dimensions Part Number Mtg. Fig. PH50PG PH75PG PH100PG PH150PG PH250PG PH350PG PH500PG PH750PG PH1000PG A A A B B B B B B Overall Dimensions inches (mm) A B C 3.00 (76.2) 3.25 (82.6) 3.25 (82.6) 4.00 (101.6) 4.50 (114.3) 4.50 (114.3) 4.75 (120.7) 5.13 (130.3) 5.25 (133.4) 4.38 (111.3) 3.88 (85.9) 4.19 (106.4) 4.94 (125.5) 5.44 (138.2) 5.19 (131.8) 5.94 (150.9) 6.69 (169.9) 6.81 (173.0) 3.19 (81.0) 3.56 (90.4) 3.63 (92.2) 3.81 (96.8) 3.81 (96.8) 4.44 (112.8) 4.31 (109.5) 4.31 (109.5) 4.94 (125.5) Mounting Centers inches (mm) D E 2.50 (63.5) 2.63 (66.8) 2.63 (66.8) 3.38 (85.9) 3.75 (95.3) 3.75 (95.3) 4.06 (103.1) 4.38 (111.3) 4.50 (114.3) 2.25 (57.2) 2.50 (63.5) 2.63 (66.8) 2.75 (69.9) 3.13 (79.5) 3.75 (95.3) 3.81 (96.8) 4.31 (109.5) 4.44 (112.8) Mounting Slot inches (mm) GXH Height with Finger Guard, inches (mm) Depth with Finger Guard inches (mm) 0.22 x 0.44 (5.6 x 11.2) 0.22 x 0.44 (5.6 x 11.2) 0.22 x 0.44 (5.6 x 11.2) 0.22 x 0.75 (5.6 x 19.1) 0.22 x 0.75 (5.6 x 19.1) 0.22 x 0.75 (5.6 x 19.1) 0.31 x 0.94 (7.9 x 23.9) 0.31 x 0.81 (7.9 x 20.6) 0.31 x 0.81 (7.9 x 20.6) 4.00 (101.6) 4.37 (111.0) 4.44 (112.8) 4.31 (109.5) 4.31 (109.5) 4.94 (125.5) 4.81 (122.2) 4.81 (122.2) 5.44 (138.2) 5.82 (147.8) 5.32 (135.1) 5.63 (143.0) 6.44 (163.6) 6.94 (176.3) 6.69 (169.9) 7.44 (189.0) 8.19 (208.1) 8.31 (211.1) Note: All dimensions are ±0.06 inches unless otherwise noted. Book 3 (14.1) www.automationdirect.com/power-transformers Transformers eTX-9 Safety: Protective Wear Terms and Conditions Prices as of April 16, 2014. Check Web site for most current prices. HPS Imperator™ 240x120 / 24x12 VAC Control Transformers Wiring Specifications Wiring HV 110V 115V 120V 1 2 3 1 4 PH***PG Schematic for 50, 75 and 100VA Units 220V 230V 240V 3 2 4 8 5 1 2 3 3 2 65 (Primary Volts) 120 240 120 240 7 6 High Voltage (HV) 4 115 230 115 230 110 220 110 220 Low Voltage (LV) 4 4 3 2 1 11V 11.5V 12V 4 2 1 22V 23V 24V HV 220V 230V 240V 4 5 6 1 2 3 4 5 6 1 2 3 3 LV 110V 115V 120V (Secondary Volts) 1 1 7 5 6 5 4 8 3 4 4 3 17 3 2 1 5 2 6 5 4 11V 11.5V 12V 3 2 1 22V 23V 24V LV HV 110V 115V 120V 220V 230V 240V 1 2 3 4 5 6 1 2 3 4 5 6 1 6 7 2 4 4 3 3 4 3 2 11V 11.5V 12V 8 5 1 4 3 2 1 LV 11.5 23 11.5 23 2 1 22V 23V 24V 11 22 11 22 Supply Lines Connect To Install Fuse Clips To 1-2, 3-4 2-3 1-2, 3-4 2-3 1, 4 1, 4 6, 7 6, 7 Unfused Unfused 1-5, 4-8 1-5, 4-8 Install Supplied Links Between Terminals Load Lines Connect To Install Fuse Clips To 3-4, 1-2 2-3 3-4, 1-2 2-3 1, 4 1, 4 4, 6 4, 6 Unfused Unfused 1-5 1-5 Install Supplied Links Between Terminals Supply Lines Connect To Install Fuse Clips To 2-3, 4-5 3-4 2-3, 4-5 3-4 2, 5 2, 5 1, 6 1, 6 Unfused Unfused 2-7, 5-8 2-7, 5-8 Install Supplied Links Between Terminals Load Lines Connect To Install Fuse Clips To 4-5, 2-3 3-4 4-5, 2-3 3-4 2, 5 2, 5 1, 5 1, 5 Unfused Unfused 2-7 2-7 PH***PG Schematic for 150VA to 500VA Units High Voltage (HV) (Primary Volts) 120 240 120 240 6 2 12 24 12 24 Install Supplied Links Between Terminals 115 230 115 230 110 220 110 220 Low Voltage (LV) (Secondary Volts) 12 24 12 24 11.5 23 11.5 23 11 22 11 22 PH***PG Schematic for 750VA and 1000VA Units High Voltage (HV) (Primary Volts) 120 240 120 240 115 230 115 230 110 220 110 220 Low Voltage (LV) (Secondary Volts) 12 24 11.5 23 11 22 Install Supplied Links Between Terminals Supply Lines Connect To Install Fuse Clips To 2-3, 4-5 3-4 2-3, 4-5 3-4 2, 5 2, 5 1, 6 1, 6 Unfused Unfused 2-7, 5-8 2-7, 5-8 Install Supplied Links Between Terminals Load Lines Connect To Install Fuse Clips To 3-4, 1-2 2-3 1, 4 1, 4 Unfused Unfused Note: secondary fuse clips not available on PH750PG or PH1000PG. Notes • - FUSES NOT INCLUDED (see Edison fuse section for fuses). • Jumper links to make primary/secondary series/parallel connections supplied, but not installed. • Secondary fuse clips supplied but not installed. Order fuses and primary fuse clips separately. Book 3 (14.1) eTX-10 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. HPS Imperator™ 480x240 / 120x25 VAC Control Transformers Specifications Features • Terminated with #8/32 slot/Phillips terminal screws complete with SEMS washer (suitable for 18 AWG to 14 AWG solid or 14 AWG stranded wire) • Insulation system: • 50 - 150VA, temperature rise 55°C (131°F), insulation class 105°C (221°F), • 250 - 500VA, temperature rise 80°C (176°F), insulation class 130°C (266°F) • SEMS (standard machine screw with lock washer) standard • Standard secondary fuse kits utilizing 13/32” x 1 ½” fuse clips included with all transformers. Fuses are not included. (See Edison fuse section for MEN fuses.) • 6 00V class, machine tool rated industrial control transformers • 5 0/60 Hertz • VA range from 50 VA up to 500 VA •C onstructed with high quality silicon steel laminations that provide optimum performance and reliability • E ncapsulated coils, encased in a custom injection molded cover, protect coils and terminations from moisture, dirt and other industrial airborne contaminants. • T emperature Range: -20°C (-4°F) to 40°C (104°F) Company Information Terminal Blocks • Optional primary fuse kits available utilizing 13/32” x 1 ½” fuse clips (See Edison fuse section for HCTR fuses.) • Optional finger-safe terminal covers • LIFETIME warranty (limited to mfg. defects) Agency Approvals • UL Listed (approved for U.S. and Canada) File E50394 • CE Mark standard on all units • RoHS Compliant Price Volt-Amp Rating* Mtg. Fig. PH50MLI PH100MLI PH250MLI PH350MLI PH500MLI $46.00 $52.00 $97.00 $116.00 50 100 250 350 A A B B $149.00 500 B Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors HPS Imperator 480x240/120x25 Control Transformer Specifications Part Number Power Distribution Blocks Primary Voltage (50/60Hz) Output Current (Amps) 25/120 Secondary Voltage (Nominal) 240x480 208x230x460 200x220x440 25x120 24x115 23x110 Impedance % Wiring Duct VA %z Total Heat Dissipation (Watts)** 2.0/0.47 4.0/0.83 10.0/2.08 14.0/2.92 50 100 250 350 8.3 8.4 7.8 7.0 11 14 29 33 4.0 5.2 10.1 11.0 20.0/4.17 500 5.0 40 16.3 Weight (lb) Wire Note: *VA capacity rated at the output of the transformer. ** Heat dissipation calculated based on full rated load on transformer. Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products B Dimensions Cable Ties Power Supplies B DC Converters Transformers and Filters C GxH C GxH Circuit Protection Tools Test Equipment A D E A Enclosures E D FIGURE A (100VA and less) Enclosure Climate Control FIGURE B (150VA to 500VA) Safety: Protective Wear HPS Imperator 480x240/120x25 Control Transformer Dimensions Part Number PH50MLI PH100MLI PH250MLI PH350MLI PH500MLI Mtg. Fig. A A B B B Overall Dimensions inches (mm) Mounting Centers inches (mm) Mounting Slot inches (mm) A B C D E GXH Height with Finger Guard, inches (mm) 3.25 (82.6) 3.25 (82.6) 4.50 (114.3) 4.50 (114.3) 4.75 (120.7) 4.06 (103.1) 4.69 (119.1) 5.19 (131.8) 5.56 (141.2) 6.69 (169.9) 3.56 (90.4) 3.63 (92.2) 4.44 (112.8) 4.44 (112.8) 4.31 (109.5) 2.63 (66.8) 2.63 (66.8) 3.75 (95.3) 3.75 (95.3) 4.06 (103.1) 2.50 (63.5) 2.63 (66.8) 3.75 (95.3) 3.75 (95.3) 4.50 (114.3) 0.22 x 0.44 (5.6 x 11.2) 0.22 x 0.44 (5.6 x 11.2) 0.22 x 0.75 (5.6 x 19.1) 0.22 x 0.75 (5.6 x 19.1) 0.31 x 0.94 (7.9 x 23.9) 4.37 (111.0) 4.44 (112.8) 4.94 (125.5) 4.94 (125.5) 4.81 (122.2) Depth with Finger Guard inches (mm) 5.32 (135.1) 6.13 (155.7) 6.38 (162.1) 7.06 (179.3) 8.19 (208.0) Note: All dimensions are ±0.06 inches unless otherwise noted. Book 3 (14.1) www.automationdirect.com/power-transformers Safety: Electrical Components Transformers eTX-11 Terms and Conditions Prices as of April 16, 2014. Check Web site for most current prices. HPS Imperator™ 480x240 / 120x25 VAC Control Transformers Wiring Specifications Wiring 6 SECTION 1 5 1 PH***MLI Schematic for 50, 75 and 100VA Units 4 HV Dotted line represents supplied jumper lead. High Voltage (HV) 8 480V/460V/440V 240V/230V/220V 3 480 240 2 6 1 5 HV 7 2 Dotted line represents supplied jumper lead. 208V/200V 6 4 460 230 208 460 230 208 440 220 200 440 220 200 (Secondary Volts) 120V/115V/110V 4 1 LV 480 240 Low Voltage (LV) 25V/24V/23V 3 110 23 110 23 (Primary Volts) 480 240 3 115 24 115 24 High Voltage (HV) 8 480V/460V/440V 120 25 120 25 7 2 Install Supplied Jumpers Between Terminals Supply Lines Connect To Install Fuse Clips To None None None 3-8 8-7 2-8 1, 3 1, 7 1, 2 6, 4 6, 4 6, 4 Unfused Unfused Unfused 1-5, 4-8 1-5, 4-8 1-5, 4-8 Install Supplied Jumpers Between Terminals Load Lines Connect To Install Fuse Clips To None None None None 1, 4 1, 3 4, 6 3, 6 Unfused Unfused 1-5 1-5 PH***MLI Schematic for 150VA to 500VA Units 5 240V/230V/220V 440 220 200 440 220 200 (Secondary Volts) 120V/115V/110V LV 460 230 208 460 230 208 Low Voltage (LV) 25V/24V/23V 4 1 480 240 7 208V/200V 3 (Primary Volts) 120 25 120 25 115 24 115 24 110 23 110 23 Install Supplied Jumpers Between Terminals Supply Lines Connect To Install Fuse Clips To None None None 8-6 4-8 3-8 2, 6 2, 4 2, 3 1, 5 1, 5 1, 5 Unfused Unfused Unfused 2-7, 5-8 2-7, 5-8 2-7, 5-8 Install Supplied Jumpers Between Terminals Load Lines Connect To Install Fuse Clips To None None None None 2, 4 2, 3 1, 4 1, 3 Unfused Unfused 2-7 2-7 Notes • FUSES NOT INCLUDED (see Edison fuse section for fuses). • Secondary fuse clips supplied but not installed. Order fuses and primary fuse clips separately. • Jumper links to make primary/secondary series/parallel connections supplied, but not installed. • Transformers secondary is NOT designed for dual voltages. Secondary voltage is either 25/24/23V or 120/115/110V. Book 3 (14.1) eTX-12 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. HPS Imperator™ Transformers Accessories – Terminal Covers and Fuse Kits Company Information Terminal Blocks Power Distribution Blocks Finger-safe terminal covers Fuse Kits These one-piece molded terminal covers are a quick and easy way to provide safety and protection in the workplace. They protect operators from potential shock hazards and guard against accidental contact with the fuses. These optional primary side fuse kits contain four fuse clips, four mounting screws, and complete instructions. Wiring Accessories The table below makes it easy to choose the correct terminal covers and fuse kits for your Hammond control transformer. ZIPLink Connection System Transformer Finger-Safe Terminal Covers Part Number Part # Pcs/ Pkg Price PH50MQMJ PH50PG FG1 PH75MQMJ PH100MQMJ PH75PG PH100PG FG2 PH150MQMJ PH250MQMJ PH350MQMJ PH500MQMJ PH750MQMJ PH1000MQMJ PH1500MQMJ PH150PG PH250PG PH350PG PH500PG Part # FGF2 1 cover FG3 1 cover Finger-safe cover for all 150VA, PH250MQMJ and PH250PG fused and $4.00 unfused control transformers. Cover fits primary or secondary side. FG4 1 cover Finger-safe cover for all 350VA, 500VA, 750VA, 1000VA, 1500VA trans$4.00 formers and the PH250MLI and PH250MGJ transformers fused and unfused control transformers. Cover fits primary or secondary side. 1 cover Finger-safe cover for all 750VA, 1000VA, 1500VA fused and unfused $4.00 control transformers. Cover fits primary or secondary side. PH750PG FG5 PH1000PG PH50MLI PH50MGJ FG2 PH100MLI PH150MGJ Description Finger-safe cover for MQMJ and PG series 50VA unfused control transformers. Cover fits primary side or secondary side. Finger-safe cover for MQMJ and PG series 50VA unfused control trans$4.00 formers. Cover fits primary side or secondary side. Finger-safe cover for all 75VA, all 100VA, PH50MLI and PH50MGJ fused $3.50 control transformers. Cover fits primary or secondary side. Finger-safe cover for 75VA, all 100VA, PH50MLI and PH50MGJ unfused $4.00 control transformers. Cover fits primary or secondary side. 1 cover Pcs/Pkg Price $3.50 FGF1 1 cover PH75MGJ PH100MGJ Primary Side Fuse Kits 1 cover 1 cover $3.50 FGF2 1 cover $4.00 FG2 1 cover $3.50 FGF2 1 cover $4.00 FG3 $4.00 1 cover PH250MLI PH250MGJ FG4 1 cover $4.00 PH350MLI PH500MLI PH350MGJ PH500MGJ FG4 1 cover $4.00 Finger-safe cover for all 75VA, all 100VA, PH50MLI and PH50MGJ unfused control transformers. Cover fits primary or secondary side. Finger-safe cover for 75VA, all 100VA, PH50MLI and PH50MGJ fused control transformers. Cover fits primary or secondary side. Finger-safe cover for all 75VA, all 100VA, PH50MLI and PH50MGJ unfused control transformers. Cover fits primary or secondary side. Finger-safe cover for 75VA, all 100VA, PH50MLI and PH50MGJ fused control transformers. Cover fits primary or secondary side. Finger-safe cover for all 150VA, PH250MQMJ and PH250PG fused and unfused control transformers. Cover fits primary or secondary side. Finger-safe cover for all 350VA, 500VA, 750VA, 1000VA, 1500VA transformers and the PH250MLI and PH250MGJ transformers fused and unfused. Cover fits primary or secondary side. Finger-safe cover for all 350VA, 500VA, 750VA, 1000VA, 1500VA transformers and the PH250MLI and PH250MGJ transformers fused and unfused. Cover fits primary or secondary side. clips, PFK1 44 fuse mounting screws $6.00 PFK2 PFK3 4 fuse clips, 4 mounting screws $6.00 Cable Ties Wire $6.00 Flexible Cord Multi-conductor Flex Cable 4 fuse clips, PFK4 4 mounting screws 1 cover PFK5 4 fuse clips, 4 mounting screws 1 cover 4 fuse clips, PFK6 4 mounting screws 1 jumper wire 4 fuse clips, PFK7 4 mounting screws 1 jumper wire $5.75 $5.75 Data Cables Wire Management Products Power Supplies $6.00 DC Converters Transformers and Filters $6.00 Circuit Protection Tools Test Equipment Enclosures 3. Ensure mounting screws used for transformer installation (not supplied) are properly sized for transformer weight. 4. When mounting fuse clips, remove the appropriate captive washer screw(s) from terminal block and install fuse clip(s) and new terminal screw(s). Fuse Clips accessories Finger-safe Cover accessories Sample Assembly Drawing for Finger Guard Installation (for 150VA to 1500VA) Panel Interface Connectors Wiring Duct 4 fuse clips, 4 mounting screws 2. For all bare wire connections, the recommended wire size range is 18 AWG to 14 AWG for solid wire, and 14 AWG for stranded. A ring or spade connector must be used if using a wire size outside the range listed above. Sample Assembly Drawing for Finger Guard Installation (for 50, 75 and 100VA) Sensor Cables and Connectors M12 Junction Blocks 1. Torque all terminal screws between 12 and 14 in-lbs. 5. Please refer to wiring instructions included with the Hammond control transformer for connection details. Multi-wire Connectors Sample Assembly Drawing for Fuse Clip Installation (for 50, 75 and 100VA) Sample Assembly Drawing for Fuse Clip Installation (for 150VA to 1500VA) Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Standard secondary fuse kits utilizing 13/32” x 1 ½” fuse clips included with all transformers. Fuses are not included. (See Edison fuse section for MEN fuses.) Book 3 (14.1) www.automationdirect.com/power-transformers Transformers eTX-13 Prices as of April 16, 2014. Check Web site for most current prices. Recommendations for Overcurrent Protection UL and CSA (North American) Standards UL and CSA (North American) Standards North American standards, including UL 508, National Electric Code 450, and the Canadian Electrical Code, Part 1, require overcurrent protection on all control circuit transformers. There are two options for overcurrent protection: Option 1 (Primary only Protection) Provide an overcurrent device in the primary circuit rated to the current of the transformer. The overcurrent limits are as follows: • Primary 9 Amps or more: no more than 125% of rated current • Primary 2 to 9 Amps: no more than 167% of rated current • Primary less than 2 Amps: no more than 300% of rated current for power circuits; no more than 500% of rated current for control circuits Note: This method is considered less desirable, as start-up inrush to the transformer can frequently surpass the current rating of the device and result in nuisance interruptions. Option 2 (Primary and Secondary Protection) The second option is to install overcurrent devices in both the primary and secondary circuits of the transformer. In this option, the secondary device must be rated no more than 125% of rated current of the transformer and the primary no more than 250%. The Canadian Electrical Code permits 300% overcurrent on the primary for this option. In both options listed, it is recommended that time delay fuses be considered to avoid unnecessary interruptions. REFERENCES: UL 508 UL 845 NEC 430-72 NEC 450-3 CEC Part 1, 26-256 Book 3 (14.1) eTX-14 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. Recommendations for Overcurrent Protection UL and CSA (North American) Standards, continued HCTR Current Limiting Class CC Fuses Part Number HCTR-25 HCTR-5 HCTR-75 HCTR1 HCTR1-25 HCTR1-5 HCTR2 HCTR2-5 HCTR3 HCTR3-5 HCTR4 HCTR5 HCTR6 HCTR7-5 HCTR8 HCTR10 HCTR15 HCTR20 HCTR25 HCTR30 PRIMARY (UL and CSA) To assist in the selection of fuses, the following chart recommends the maximum primary fuse rating in amperes. The first number shown is the maximum overcurrent protection when the primary current is less than 2 amps and the overcurrent protection device is rated for 300%. The second number (shown in brackets) is recommended when the primary is less than 2 amps and the overcurrent device is to be rated at 500% of rated current. Where only one number is indicated, the primary is 2 amps or more and one rating of overcurrent protection is shown as optimal. Choose the next higher fuse rating if these numbers do not correspond with standard fuse selections. Recommended Maximum Primary Fuse Ratings in Amps Where Primary Current is less than 2 Amps. Primary Overload Voltage Protection 50 115 120 220 208 230 240 277 380 440 460 480 300% 500% 300% 500% 300% 500% 300% 500% 300% 500% 300% 500% 300% 500% 300% 500% 300% 500% 300% 500% 300% 500% 1.25 (2.0) 1.25 (2.0) 0.6 (1.125) 0.6 (1.125) 0.6 (1.0) 0.6 (1.0) 0.5 (0.8) 0.3 (0.6) 0.3 (0.5) 0.3 (0.5) 0.3 (0.5) AMP Rating Pcs/Pkg Weight Price 0.25 0.5 0.75 1 1.25 1.5 2 2.5 3 3.5 4 5 6 7.5 8 10 15 20 25 30 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb $89.00 $79.00 $103.00 $81.00 $100.00 $80.00 $80.00 $89.00 $81.00 $98.00 $86.00 $84.00 $89.00 $98.00 $89.00 $87.00 $80.00 $86.00 $85.00 $87.00 100 150 250 350 500 750 1000 1500 2000 3000 5000 2.5 (4.0) 2.25 (4.0) 1.25 (2.25) 1.4 (2.25) 1.25 (2.0) 1.25 (2.0) 1.0 (1.8) 0.75 (1.25) 0.6 (1.125) 0.6 (1.0) 0.6 (1.0) 10.0 – 10.0 – 6.0 – 6.0 – 6.0 – 5.0 – 5.0 – 5.6 (9.0) 5.0 (8.0) 4.5 (8.0) 4.5 (7.5) 15.0 – 15.0 – 8.0 – 8.0 – 8.0 – 7.0 – 6.0 – 4.5 – 4.0 – 3.5 – 3.5 – 20.0 – 15.0 – 12.0 – 12.0 – 10.0 – 10.0 – 9.0 – 6.25 – 6.0 – 6.0 – 5.0 – Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products 25.0 – 20.0 – 15.0 – 15.0 – 15.0 – 15.0 – 12.0 – 9.0 – 8.0 – 8.0 – 7.0 – – – – – 20.0 – 20.0 – 20.0 – 15.0 – 15.0 – 15.0 – 12.0 – 12.0 – 10.0 – DC Converters – – – – 30.0 – 30.0 – 30.0 – 30.0 – 25.0 – 20.0 – 15.0 – 15.0 – 15.0 – Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) www.automationdirect.com/power-transformers Wiring Accessories Power Supplies 1.8 (3.2) 1.8 (3.2) 1 .0 (1.6) 1.0 (1.8) 0.8 (1.6) 0.8 (1.5) 0.8 (1.25) 0.5 (0.8) 0.5 (0.8) 0.4 (0.8) 0.4 (0.75) 8.0 – 8.0 – 4.0 – 4.0 – 4.0 – 3.5 – 5.0 – 3.5 (6.25) 3.2 (5.6) 3.2 (5.0) 3.0 (5.0) Power Distribution Blocks Multi-wire Connectors Note: S ee HCTR fuse catalog page for characteristic curves. 75 5.0 – 5.0 – 4.5 (7.5) 5.0 (8.0) 4.5 (7.5) 4.0 (7.0) 3.5 (9.0) 2.5 (4.5) 2.25 (3.5) 2.25 (3.5) 2.0 (3.5) Terminal Blocks ZIPLink Connection System Hammond Transformers VA RATING 3.5 4.0 (6.5) – 3.5 4.0 (6.5) – 2 .0 3.2 (3.2) (5.6) 2.0 3.5 (3.5) (6.0) 1.8 3. 2 (3.2) (5.0) 1.8 3.0 (3.0) (5.0) 1.6 2.5 (4.5) (6.25) 1.125 1.8 (1.8) (3.2) 1 .0 1.6 (1.6) (2.8) 0.8 1.6 (1.6) (2.5) 0.8 1.5 (1.5) (2.5) Company Information Transformers eTX-15 Prices as of April 16, 2014. Check Web site for most current prices. Recommendations for Overcurrent Protection UL and CSA (North American) Standards, continued MEN General Purpose Midget Class Fuses SECONDARY Part Number MEN-5 MEN-6 MEN1 MEN1-4 MEN1-5 MEN2 MEN2-5 MEN3 MEN3-5 MEN4 MEN5 MEN6 MEN7 MEN8 MEN10 MEN12 MEN15 MEN20 MEN25 MEN30 The overcurrent protection listed below, in amperes, is 125% of the rated current of the transformer. Choose the next higher fuse rating if these numbers do not correspond with standard fuse selections. Recommended Maximum Secondary Fuse Ratings in Amps. AMP Rating Pcs/Pkg Weight Price 0.5 0.6 1 1.4 1.5 2 2.5 3 3.5 4 5 6 7 8 10 12 15 20 25 30 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 10/1 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb 0.2 lb $33.00 $32.50 $30.50 $38.50 $32.00 $28.00 $30.50 $28.50 $28.00 $28.50 $28.00 $30.50 $28.00 $28.50 $28.00 $32.50 $29.00 $30.50 $33.00 $30.50 Note: See MEN fuse catalog page for characteristic curves. Hammond Transformers VA RATING Secondary Overload Voltage Protection 50 75 100 150 250 350 500 750 1000 1500 2000 3000 5000 12 24 110 115 120 220 230 125% 5.3 7.9 11.0 16.0 27.0 – – – – – – – – 125% 2.7 4.0 5.3 7.9 14.0 19.0 27.0 – – – – – – 125% 0.6 0.9 1.2 1.8 2.9 4.0 5.7 8.6 12.0 18.0 23.0 – – 125% 0.6 0.9 1.1 1.7 2.8 3.9 5.5 8.2 11.0 17.0 22.0 – – 125% 0.6 0.8 1.1 1.6 2.7 3.7 5.3 7.9 11.0 16.0 21.0 – – 125% 0.3 0.5 0.6 0.9 1.5 2.0 2.9 4.3 5.7 8.6 12.0 18.0 29.0 125% 0.3 0.5 0.6 0.9 1.4 2.0 2.8 4.1 5.5 8.2 11.0 17.0 28.0 Book 3 (14.1) eTX-16 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. HPS Fortress™ Commercial Encapsulated Transformers Company Information Terminal Blocks Power Distribution Blocks Features Totally enclosed to seal out moisture and airborne contaminants Easily accessible nameplate Installation is made quick and easy with keyhole mounting slots Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable All units are encapsulated with an electrical grade silica sand and resin compound Data Cables NEMA 3R enclosure meets or exceeds listing criteria including NEMA and ANSI standards for indoor and outdoor applications Conduit knockouts and an easily accessible wiring compartment Power Supplies DC Converters Transformers and Filters Circuit Protection Voltage Regulation Tools Test Equipment Voltage regulation in transformers is the difference between the “No-Load voltage” and the “Full-Load voltage”. This is expressed in terms of percentage. Regulation = Percentage Wire Management Products ENo-Load - EFull Load EFull Load Enclosures Enclosure Climate Control (100%) Safety: Electrical Components Safety: Protective Wear The secondary voltage (nominal) listed in these pages are at Full-Load, meaning the point at which the transformer is operating at maximum permissible secondary current. No-Load voltage can increase 6 to 10% max. Terms and Conditions Warning: Secondary voltages of transformers may damage some loads. For example, a transformer connected as 480/120 Volt but applied 495 Volt primary can produce at No-Load a voltage of 134 Volts which will damage the inputs of a PLC D0-06AA, whose maximum input voltage is 132 Volt. Notice that the current of D0-06AA input is 10mA, making it very close to No-Load. Book 3 (14.1) www.automationdirect.com/power-transformers Transformers eTX-17 Prices as of April 16, 2014. Check Web site for most current prices. HPS Fortress™ Commercial Encapsulated Transformers Primary 480 x 240 VAC Secondary 240 x 120 VAC Features •R atings: Single phase from 0.50kVA to 25kVA; 60 Hz • Electrostatic Shield: Standard on all single phase units 0.75kVA and larger •Q uality Design: All units are encapsulated with electrical grade silica sand and resin compounds which completely enclose the core and coil to seal out moisture, airborne contaminants and eliminates corrosion and deterioration. • Insulation: Offering UL class 130°C (266°F) insulation, 95°C (203°F) temperature rise up to 1kVA on single phase; 180°C (356°F) insulation, 135°C (275°F) temperature rise on all units over 1kVA on single phase. Quiet operation with sound levels below NEMA standards. • E nclosures: NEMA 3R enclosures meet or exceed listing criteria including NEMA, ANSI, and OSHA standards for indoor and outdoor service. • To provide NEMA 3R protection (protection from falling rain), the transformer must be mounted vertically with the mounting tabs facing up. • Rear and side entry conduit knockouts into an easily accessible and roomy wiring compartment. • Color is ANSI 61 gray, UL50 • Taps are convenient to select output voltage. •W iring compartment: Provides tinned copper lead wire terminations up to 5kVA, terminal pad termination on 7.5KVA and larger and standard ground lug assembly for easy cable installation. • Output voltage adjustable by taps. •T emperature Range: -20°C (-4°F) to average ambient temperature 30°C (86°F), not to exceed 40°C (104°F) C1FC50LE • I nstallation made quick and easy: All encapsulated transformers are designed for wall mounting and include keyhole mounting slots. • 10 year warranty (limited to mfg. defects) Agency Approvals • UL Listed File No. E50394 (Type Q) • CSA File No. LR3902 (Type Q) • CE (up to 10 kVA) • RoHS C1F005LES C1F1C5LES HPS Fortress 480x240/240x120 Encapsulated Transformer Specifications %z 4.17/2.08 500 7.6 35.8 15.0 6.25/3.13 750 5.6 57.2 18.0 1.0 8.33/4.17 1000 4.8 75.3 22.0 1.5 12.5/6.25 1500 4.1 100.0 25.0 $259.00 2.0 16.7/8.33 2000 4.3 121.6 40.0 $319.00 3.0 25.0/12.5 3000 3.7 160.8 55.0 $459.00 5.0 41.7/20.8 5000 4.2 314.0 88 $585.00 7.5 62.5/31.3 7500 3.6 402.0 145 $675.00 10 83.3/41.6 10000 3.7 525.0 165 $869.00 15 125/62.5 15000 2.4 585.0 286 $1,069.00 25 208.3/104.2 25000 2.0 838.0 346 kVA Rating C1FC50LE C1FC75LES C1F1C0LES C1F1C5LES C1F002LES C1F003LES C1F005LES C1F007LES C1F010LES C1F015LES** C1F025LES** $116.00 0.50 $145.00 0.75 $175.00 $209.00 240x480 Secondary Voltage (Nominal) Impedance % VA Price Primary Voltage (60Hz) Output Current (Amps) 120/240 Total Heat Dissipation (Watts)* Part Number 120x240 Product Wt/Lbs * Heat dissipation calculated based on full rated load on transformer. ** Not CE Book 3 (14.1) eTX-18 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. HPS Fortress™ Commercial Encapsulated Transformers Primary 480 x 240 VAC Secondary 240 x 120 VAC Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories Dimensions Figure A - 500VA to 3kVA ZIPLink Connection System Figure B - 5kVA to 25kVA Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Dimensions inches [mm] * Front bottom panel is hinged for access to terminals, shaded areas show view of rear mounting holes and knockout. Wire Management Products HPS Fortress 480x240/240x120 Encapsulated Transformer Dimensions Part Number Overall Dimensions in (mm) Mtg. Fig. A C1FC50LE C1FC75LES C1F1C0LES C1F1C5LES C1F002LES C1F003LES C1F005LES C1F007LES C1F010LES C1F015LES C1F025LES B C Mounting Holes in (mm) D E Mtg. Hole Dia. in (mm) F G Power Supplies Rear Mtg. Holes in (mm) Knock Out Dimensions in (mm) H J K L A 5.00 (127.0) 4.75 (120.7) 9.25 (235.0) 8.25 (209.6) 3.88 (98.6) 7.75 (196.9) 0.22 (5.6) 1.25 (31.8) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8) A 5.00 (127.0) 4.75 (120.7) 9.25 (235.0) 8.25 (209.6) 3.88 (98.6) 7.75 (196.9) 0.22 (5.6) 1.25 (31.8) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8) A 5.88 (149.4) 5.50 (139.7) 10.00 (254.0) 8.50 (215.9) 4.13 (104.9) 8.25 (209.6) 0.28 (7.1) 1.25 (31.8) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) A 5.88 (149.4) 5.50 (139.7) 10.00 (254.0) 8.50 (215.9) 4.13 (104.9) 8.25 (209.6) 0.28 (7.1) 1.25 (31.8) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) A 7.00 (177.8) 6.50 (165.1) 11.25 (285.8) 9.75 (247.7) 5.38 (136.7) 9.50 (241.3) 0.28 (7.1) 1.25 (31.8) 1.50 (38.1) 1.50 (38.1) 2.00 (50.8) M N/A 7.00 (177.8) 6.50 (165.1) 11.25 (285.8) 9.75 (247.7) 5.38 (136.7) 9.50 (241.3) 0.28 (7.1) 1.25 (31.8) 1.50 (38.1) 1.50 (38.1) 2.00 (50.8) B 10.00 (254.0) 7.75 (196.9) 17.25 (438.2) 15.25 (387.4) 7.38 (187.5) 15.38 (390.7) 0.44 (11.2) 1.25 (31.8) 4.00 (101.6) 2.00 (50.8) 2.00 (50.8) 6.00 (152.4) B 12.25 (311.2) 9.25 (234.9) 17.63 (447.8) 15.56 (395.2) 9.38 (238.3) 14.88 (377.9) 0.44 (11.2) 2.00 (50.8) 5.00 (127.0) 2.00 (50.8) 2.00 (50.8) 8.00 (203.2) B 12.25 (311.2) 9.25 (234.9) 20.88 (530.4) 18.88 (479.6) 9.38 (238.3) 18.13 (460.5) 0.44 (11.2) 2.00 (50.8) 5.00 (127.0) 2.00 (50.8) 2.00 (50.8) 8.00 (203.2) B 14.50 (368.3) 10.75 (273.1) 21.38 (543.1) 19.38 (492.3) 11.63 (295.4) 18.63 (473.2) 0.44 (11.2) 2.00 (50.8) 6.00 (152.4) 2.00 (50.8) 2.00 (50.8) 10.00 (254.0) B 14.50 (368.3) 10.75 (273.1) 27.38 (695.5) 24.88 (631.9) 11.13 (282.7) 24.50 (622.3) 0.56 (14.2) 2.00 (50.8) 6.00 (152.4) 2.00 (50.8) 2.00 (50.8) 10.00 (254.0) Note: All dimensions have a tolerance of ±0.06 inches unless otherwise noted. To provide NEMA 3R protection (protection from falling rain), the transformer must be mounted vertically with the mounting tabs facing up. Additional information in installation insert. Book 3 (14.1) Transformers Transformers and Filters Circuit Protection Tools A www.automationdirect.com/power-transformers DC Converters eTX-19 Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Prices as of April 16, 2014. Check Web site for most current prices. HPS Fortress™ Commercial Encapsulated Transformers Primary 480 x 240 VAC Secondary 240 x 120 VAC Wiring Diagram - For 500VA to 5kVA SCHEMATIC Primary Volts 480 240 Secondary Volts 240 120/240 120 CONNECTIONS Connect lines to Inter-connect H1, H4 H1, H4 H2-H3 H1-H3, H2-H4 Connect lines to X1, X4 X1, X2, X4 X1, X2 Inter-connect X2-X3 X2-X3 X2-X4, X1-X3 Wiring Diagram - For 7.5kVA to 25kVA SCHEMATIC HV H1 7 5 31 X4 X2 H2 2468 X3 LV HV H1 OR X1 OR Primary Volts 7 5 31 X4 2468 LV X3 LV Connect lines to Inter-connect H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 1-2 2-3 3-4 4-5 5-6 6-7 7-8 H1-2, H2-1 H1-4, H2-3 H1-6, H2-5 H1-8, H2-7 504 492 480 468 456 444 432 H2 X2 CONNECTIONS 240 228 216 X1 LV Secondary Volts Connect lines to Inter-connect 240 120 120/240 X1, X4 X1, X2 X1, X2, X4 X2- X3 X2-X4, X1-X3 X2-X3 Termination* Part No. C1FC50LE C1FC75LES C1F1C0LES C1F1C5LES C1F002LES C1F003LES C1F005LES C1F007LES C1F010LES C1F015LES C1F025LES HV LV #18 AWG Leads #18 AWG Leads #18 AWG Leads #14 AWG Leads #18 AWG Leads #14 AWG Leads #14 AWG Leads #14 AWG Leads #14 AWG Leads #14 AWG Leads #14 AWG Leads #14 AWG Leads #14 AWG Leads #12 AWG Leads #12 AWG Leads Terminal Pad 1C #10 AWG Leads Terminal Pad 1C #8 AWG Leads Terminal Pad 1A #6 AWG Leads Terminal Pad 1A Terminal Pad Diagram 1A = 0.28 [7.1] DIA 1C = 0.22 [5.6] DIA Dimensions inches [mm] * Transformers are provided with copper leads or copper terminal pads. Book 3 (14.1) eTX-20 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. HPS Fortress™ Commercial Encapsulated Transformers Primary 277/240/208/120 VAC Secondary 240 x 120 VAC Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories Features •R atings: Single phase from 100VA to 5kVA; 60 Hz • Electrostatic Shield: Standard on all single phase units 0.75kVA and larger •Q uality Design: All units are encapsulated with electrical grade silica sand and resin compounds which completely enclose the core and coil to seal out moisture, airborne contaminants and eliminates corrosion and deterioration. • Insulation: Offering UL class 130°C (266°F) insulation, 80°C (176°F) temperature rise up to 1kVA on single phase; 180°C (356°F) insulation, 135°C (275°F) temperature rise on all units over 1kVA on single phase. Quiet operation with sound levels below NEMA standards. • E nclosures: NEMA 3R enclosures meet or exceed listing criteria including NEMA, ANSI, and OSHA standards for indoor and outdoor service. • Rear and side entry conduit knockouts into an easily accessible and roomy wiring compartment. • Color is ANSI 61 gray, UL50 •W iring compartment: Provides tinned copper lead wire terminations and standard ground lug assembly for easy cable installation. • Taps are convenient to select output voltage. • Output voltage adjustable by taps. •T emperature Range: -20°C (-4°F) to average ambient temperature 30°C (86°F), not to exceed 40°C (104°F) • I nstallation made quick and easy: All encapsulated transformers are designed for wall mounting and include keyhole mounting slots. • 10 year warranty (limited to mfg. defects) Agency Approvals • UL Listed File No. E50394 (Type Q) • CSA File No. LR3902 (Type Q) • CE • RoHS ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection C1FC10WE C1F1C0WES C1F005WES Test Equipment HPS Fortress Encapsulated Transformer Specifications Part Number Price kVA Rating C1FC10WE C1FC25WE C1FC50WE C1F1C0WES C1F002WES C1F003WES C1F005WES $96.00 0.10 $119.00 $139.00 $199.00 1.0 $298.00 2.0 $385.00 $539.00 Primary Voltage (60Hz) Secondary Voltage (Nominal) Output Current (Amps) 120/240 Impedance % Total Heat Wt/ Dissipation Product Lbs (Watts)* VA %z 0.83/0.42 100 12.6 27 6.36 0.25 2.08/1.04 250 12.2 52 8.25 0.50 4.16/2.08 500 8.9 71 14.0 8.33/4.16 1000 5.4 91 22.0 16.67/8.33 2000 3.8 130 50.0 3.0 25.0/12.5 3000 4.3 138 86.0 5.0 41.67/20.83 5000 4.3 380 150.0 120/208/240/277 120/240 Note: * Heat dissipation calculated based on full rated load on transformer. Book 3 (14.1) www.automationdirect.com/power-transformers Tools Transformers eTX-21 Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Prices as of April 16, 2014. Check Web site for most current prices. HPS Fortress™ Commercial Encapsulated Transformers Primary 277/240/208/120 VAC Secondary 240 x 120 VAC Dimensions Figure A - 100VA to 2kVA Figure B - 3kVA to 5kVA * Front bottom panel is hinged for access to terminals, shaded areas show view of rear mounting holes and knockout. Dimensions inches [mm] HPS Fortress Encapsulated Transformer Dimensions Part Number Mtg. Fig. C1FC10WE C1FC25WE C1FC50WE C1F1C0WES C1F002WES C1F003WES C1F005WES A Overall Dimensions in (mm) B C D Mounting Holes in (mm) E F Mounting Hole Dia. in (mm) G Knock Out Dimensions in (mm) H J K L A 3.75 (95.3) 5.25 (133.4) 7.25 (184.2) 6.25 (158.8) 2.50 (63.5) 5.63 (143.0) 0.22 (5.6) 1.25 (31.8) A 3.75 (95.3) 5.25 (133.4) 7.25 (184.2) 6.25 (158.8) 2.50 (63.5) 5.63 (143.0) 0.22 (5.6) 1.25 (31.8) 0.8 (20.3) 1.50 (38.1) 2.00 (50.8) N/A 1.50 (38.1) 2.00 (50.8) A 5.00 (127.0) 4.75 (120.7) 9.25 (234.9) 8.25 (209.5) 3.88 (98.5) 7.75 (196.9) 0.22 (5.6) 1.25 (31.8) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8) A 5.88 (149.4) 5.50 (139.7) 10.00 (254.0) 8.50 (215.9) 4.13(104.9) 8.25 (209.6) 0.28 (7.1) 1.25 (31.8) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) A 7.00 (177.8) 6.50 (165.1) 11.25 (285.8) 9.75 (247.7) 5.38 (136.7) 9.50 (241.3) 0.28 (7.1) 1.25 (31.8) 1.50 (38.1) 1.50 (38.1) 2.00 (50.8) B 10.00 (254.0) 7.75 (196.9) 17.25 (438.2) 15.25 (387.4) 7.38 (187.5) 15.38 (390.7) 0.44 (11.2) 1.25 (31.8) 4.00 (101.6) 2.00 (50.8) 2.00 (50.8) B 10.00 (254.0) 7.75 (196.9) 17.25 (438.2) 15.25 (387.4) 7.38 (187.5) 15.38 (390.7) 0.44 (11.2) 1.25 (31.8) 4.00 (101.6) 2.00 (50.8) 2.00 (50.8) Note: All dimensions have a tolerance of ±0.06 inches unless otherwise noted. To provide NEMA 3R protection (protection from falling rain), the transformer must be mounted vertically with the mounting tabs facing up. Additional information in installation insert. Book 3 (14.1) eTX-22 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. HPS Fortress™ Commercial Encapsulated Transformers Primary 277/240/208/120 VAC Secondary 240 x 120 VAC Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories Wiring Diagram - For 100VA to 2kVA ZIPLink Connection System SCHEMATIC H3 H5 H2 H4 H1 H3 H5 H2 H4 H1 OR HV X4 CONNECTIONS X2 X3 X1 LV OR Primary Volts Connect lines to Inter-connect 277 240 208 120 H1, H5 H1, H4 H1, H3 H1, H2 - HV X4 X2 X3 LV Secondary Volts X1 240 120/240 120 LV LV Connect lines to Inter-connect X1, X4 X1, X2, X4 X1, X2 X2-X3 X2-X3 X2-X4, X1-X3 Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Wiring Diagram - For 3kVA and 5kVA SCHEMATIC Flexible Cord Primary Volts CONNECTIONS Connect lines to Inter-connect H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 1-2 2-3 3-4 4-5 5-6 6-7 7-8 277 HV H1 7 5 31 X4 X2 H2 2468 X3 LV H1 OR X1 OR 7 5 31 X4 240 HV 208 2468 X2 LV H2 X3 LV Multi-conductor Flex Cable 120 Wire Management Products Power Supplies DC Converters Transformers and Filters X1 LV Secondary Volts Connect lines to Inter-connect 240 120 120/240 X1, X4 X1, X2 X1, X2, X4 X2- X3 X2-X4, X1-X3 X2-X3 Circuit Protection Tools Test Equipment Enclosures Termination* Part No. C1FC10WE C1FC25WE C1FC50WE C1F1C0WES C1F002WES C1F003WES C1F005WES Data Cables HV LV #18 AWG Leads #18 AWG Leads #18 AWG Leads #18 AWG Leads #18 AWG Leads #18 AWG Leads #14 AWG Leads #14 AWG Leads #14 AWG Leads #14 AWG Leads #10 and #14 AWG Leads #14 AWG Leads #6 AWG Leads #12 AWG Leads Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions * Transformers are provided with copper leads. Book 3 (14.1) www.automationdirect.com/power-transformers Transformers eTX-23 Prices as of April 16, 2014. Check Web site for most current prices. HPS FortressTM Commercial Encapsulated Transformers Primary 480**/440/416/400/380 x 240**/220/208/200/190VAC Secondary 240 x 120 VAC Features •R atings: Single phase from 0.25kVA to 5kVA; 50/60 Hz** • Electrostatic Shield: Standard on all single phase units 0.75kVA and larger •Q uality Design: All units are encapsulated with electrical grade silica sand and resin compounds which completely enclose the core and coil to seal out moisture, airborne contaminants and eliminates corrosion and deterioration. • Insulation: Offering UL class 130°C (266°F) insulation, 95°C (203°F) temperature rise up to 1kVA on single phase; 180°C (356°F) insulation, 135°C (275°F) temperature rise on all units over 1kVA on single phase. Quiet operation with sound levels below NEMA standards. • E nclosures: NEMA 3R enclosures meet or exceed listing criteria including NEMA, ANSI, and OSHA standards for indoor and outdoor service. • Rear and side entry conduit knockouts into an easily accessible and roomy wiring compartment. •W iring compartment: Provides tinned copper lead wire terminations and standard ground lug assembly for easy cable installation. • Taps are convenient to select output voltage. • Output voltage adjustable by taps. •T emperature Range: -20°C (-4°F) to average ambient temperature 30°C (86°F), not to exceed 40°C (104°F) C1FC25XE • I nstallation made quick and easy: All encapsulated transformers are designed for wall mounting and include keyhole mounting slots. • 10 year warranty (limited to mfg. defects) Agency Approvals • UL Listed File No. E50394 (Type Q) • CSA File No. LR3902 (Type Q) • CE • RoHS C1F1C0XES C1F005XES HPS Fortress Encapsulated Transformer Specifications Part Number Price kVA Rating C1FC25XE C1FC50XE C1F1C0XES C1F002XES C1F003XES $119.00 0.25 $139.00 0.50 $209.00 1.0 $319.00 2.0 $415.00 3.0 C1F005XES $579.00 5.0 Primary Voltage (50/60Hz)** 190/200/208/ 220/240 x 380/400/416/ 440/480 Secondary Voltage (Nominal) 120/240 Output Current (Amps) 120/240 Impedance % VA 2.08/1.04 %z Total Heat Dissipation (Watts)* Product Wt/Lbs 250 13.0 76 8.25 4.16/2.08 500 10.7 95 14.0 8.33/4.16 1000 5.4 110 26.0 16.67/8.33 2000 4.5 140 52.0 25.0/12.5 3000 4.3 145 65.0 41.67/20.83 5000 4.3 351 115.0 * Heat dissipation calculated based on full rated load on transformer. ** The primary voltage ratio of 240 or 480 is available at 60Hz only with a secondary voltage of approximately 130/262V Book 3 (14.1) eTX-24 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. HPS Fortress™ Commercial Encapsulated Transformers Primary 480/440/416/400/380 x 240/220/208/200/190 VAC Secondary 240 x 120 VAC Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories Dimensions ZIPLink Connection System Figure B - 3kVA to 5kVA Figure A - 250VA to 2kVA Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Dimensions inches [mm] * Front bottom panel is hinged for access to terminals, shaded areas show view of rear mounting holes and knockout. Wire Management Products HPS Fortress Encapsulated Transformer Dimensions Part Number C1FC25XE C1FC50XE C1F1C0XES C1F002XES C1F003XES C1F005XES Mtg. Fig. A Overall Dimensions in (mm) B C D Mounting Holes in (mm) E F Mounting Hole Dia. in (mm) G Data Cables Knock Out Dimensions in (mm) H J K L N/A 1.50 (38.1) 2.00 (50.8) Power Supplies DC Converters A 3.75 (95.3) 5.25 (133.4) 7.25 (184.2) 6.25 (158.8) 2.50 (63.5) 5.63 (143.0) 0.22 (5.6) 1.25 (31.8) A 4.50 (114.3) 5.75 (146.1) 7.25 (184.2) 6.25 (158.8) 3.13 (79.5) 5.63 (143.0) 0.22 (5.6) 1.25 (31.8) 0.81 (20.6) 1.50 (38.1) 2.00 (50.8) A 5.88 (149.4) 5.50 (139.7) 10.00 (254.0) 8.50 (215.9) 4.13 (104.9) 8.25 (209.6) 0.28 (7.1) 1.25 (31.8) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) Circuit Protection Tools A 7.00 (177.8) 6.50 (165.1) 11.25 (285.8) 9.75 (247.7) 5.38 (136.7) 9.50 (241.3) 0.28 (7.1) 1.25 (31.8) 1.50 (38.1) 15.0 (381.0) 2.00 (50.8) B 10.00 (254.0) 7.75 (196.9) 17.25 (438.2) 15.25 (387.5) 7.38 (187.5) 15.38 (390.7) 0.44 (11.2) 1.25 (31.8) 4.00 (101.6) 2.00 (50.8) 2.00 (50.8) B 10.00 (254.0) 7.75 (196.9) 17.25 (438.2) 15.25 (387.5) 7.38 (187.5) 15.38 (390.7) 0.44 (11.2) 1.25 (31.8) 4.00 (101.6) 2.00 (50.8) 2.00 (50.8) Note: All dimensions have a tolerance of ±0.06 inches unless otherwise noted. To provide NEMA 3R protection (protection from falling rain), the transformer must be mounted vertically with the mounting tabs facing up. Additional information in installation insert. Transformers and Filters Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) www.automationdirect.com/power-transformers Transformers eTX-25 Prices as of April 16, 2014. Check Web site for most current prices. HPS Fortress™ Commercial Encapsulated Transformers Primary 480/440/416/400/380 x 240/220/208/200/190 VAC Secondary 240 x 120 VAC Wiring Diagram - For 250VA to 2kVA SCHEMATIC H1 H2 H3 H4 H5 X4 H6 X3 Primary Volts 480 (60Hz) 440 (50/60Hz) 416 (50/60Hz) 400 (50/60Hz) 380 (50/60Hz) 240 (60 Hz) 220 (50/60Hz) 208 (50/60Hz) 200 (50/60Hz) 190 (50/60Hz) H7 H8 H9 H10 X2 CONNECTIONS Connect lines to Inter-connect H1, H10 H1, H10 H1, H9 H1, H8 H1, H7 H1, H10 H1, H10 H1, H9 H1, H8 H1, H7 H5-H6 H5-H6 H4-H6 H3-H6 H2-H6 H1-H6, H5-H10 H1-H6, H5-H10 H1-H6, H4-H9 H1-H6, H3-H8 H1-H6, H2-H7 Secondary Volts Connect lines to Inter-connect 240 120/240 120 X1, X4 X1, X2, X4 X1, X4 X2-X3 X2-X3 X2-X4, X1-X3 X1 Wiring Diagram - For 3kVA and 5kVA SCHEMATIC Primary Volts CONNECTIONS Connect lines to Inter-connect H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 H1, H2 1-2 2-3 3-4 4-5 5-6 6-7 7-8 H1-2, H2-1 H1-4, H2-3 H1-6, H2-5 H1-8, H2-7 440 or 480 HV H1 7 5 31 X4 X2 H2 2468 X3 LV OR X1 OR 416 HV H1 7 5 31 X4 400 2468 X2 LV H2 X3 LV 380 220 or 240 208 200 190 X1 LV Secondary Volts Connect lines to Inter-connect 240 120 120/240 X1, X4 X1, X2 X1, X2, X4 X2- X3 X2-X4, X1-X3 X2-X3 Termination* Part No. C1FC25XE C1FC50XE C1F1C0XES C1F002XES C1F003XES C1F005XES HV LV #18 AWG Leads #18 AWG Leads #18 AWG Leads #18 AWG Leads #18 AWG Leads #14 AWG Leads #14 AWG Leads #14 AWG Leads #14 AWG Leads #14 AWG Leads #14 AWG Leads #12 AWG Leads * Transformers are provided with copper leads. Book 3 (14.1) eTX-26 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. Jefferson Electric Buck-Boost Transformers Terminal Blocks What is a buck-boost transformer? Power Distribution Blocks Buck-boost transformers are designed to maximize the performance and life of electrical equipment. They are typically used to power loads with specific voltage requirements that differ from the available line voltage. Wiring Accessories ZIPLink Connection System Multi-wire Connectors The 2008 NEC Handbook Section 210.9 provides the following definition for a buck-boost transformer: Sensor Cables and Connectors A buck-boost transformer is classified as an autotransformer. A buck-boost transformer provides a means of raising (boosting) or lowering (bucking) a supply line voltage by a small amount (usually no more than 20 percent). A buck-boost is a transformer with two primary windings (H1-H2 and H3-H4) and two secondary windings (X1-X2 and X3-X4). Its primary and secondary windings are connected so that the electrical characteristics are changed from a transformer that has its primary and secondary windings isolated from each other to one that has primary and secondary windings connected to buck or boost the voltage as an autotransformer, correcting voltage by up to 20 percent. A single unit is used to boost or buck single-phase voltage. Two or three units are used to boost or buck three-phase voltage. An autotransformer requires little physical space, is economical, and above all, is efficient. A Buck-Boost transformer can have two main applications: 1. When connected as an autotransformer, you can buck (lower) or boost (raise) available line voltage anywhere from 5 to 20 percent. 2. When connected as an isolation transformer, they can be used to step-down supply power to low voltage circuits at the nameplate rating listed. Standards/Approvals Company Information M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Applications* Wire Management Products • Air conditioners • Heating elements • Motor applications (not motor control circuits per NFPA 79 9.1.1.1) • 277 volt supply for lighting systems Power Supplies DC Converters Transformers and Filters Features • Encapsulated with electrical grade resin • Cores of high-quality electrical steel • Aluminum/copper windings (see nameplate for product specific information) • 60 Hz operation • NEMA 3R-rated enclosures • 135ºC temperature rise, 180ºC insulation class or 95ºC temperature rise, 130ºC insulation class depending on kVA size • Heat-cured ASA-61 gray powder coat finish • Slotted mounting holes for quick and easy mounting • Permanently affixed wiring diagram • 10-year limited warranty (limited to mfg. defects) • Single-phase encapsulated isolation transformer ratings 50VA to 2kVA • Ambient temperature 0 - 25ºC (32 - 77ºF) (Per UL506, UL5085-1, 2 General Purpose Transformers) • Built in accordance with UL1446, CAN/ CSA - C22.2 No. 0 • Agency Approval UL File #E4466 * Note: Buck-boost transformers do not compensate for fluctuating line voltages. They should only be used when line voltage is relatively constant. Book 3 (14.1) www.automationdirect.com/power-transformers Transformers eTX-27 Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Prices as of April 16, 2014. Check Web site for most current prices. Buck-Boost Single-phase Connections NEC Handbook 2008 Exhibit 210.18 Typical single-phase connection diagrams for buck or boost transformers connected as autotransformers to change 240 volts single-phase to 208 volts and vice versa. Boost (increase) HV = High Voltage LV = Low Voltage Buck (decrease) Courtesy of NFPA, from 2008 Handbook Difference between an autotransformer and an isolation transformer The principal difference between an autotransformer and an isolation transformer is the separation of secondary windings. In an autotransformer, the input (or primary) and the output (or secondary) are electrically connected, while in an isolation transformer they are completely separated, as shown to the right. Because autotransformers require fewer windings and smaller cores, they are typically lighter and less costly than conventional isolation transformers with the same ratings. Autotransformers do have some performance advantages too. They have increased power handling capability, flatter frequency response, lower insertion loss and lower distortion than conventional transformers of similar size and cost. They do not, however, provide electrical isolation or stabilize fluctuating supply line voltages. Autotransformer (“Autoformers”) Autotransformers are best suited for applications where the line voltage needs to be matched to a protected piece of equipment, for example to adapt a piece of equipment manufacturered in one country to operate in another where the line voltage is slightly different. Autotransformers are a smart choice if the difference between the input and desired output voltages is nominal. Isolation (or Insulating) Transformer Book 3 (14.1) eTX-28 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. Fusing Buck-Boost Transformers Company Information Terminal Blocks The method for determining the correct size overcurrent protection for an autotransformer is covered in the 2008 National Electric Code (NEC) 450.4 Autotransformers 600 Volts, Nominal, or Less. Power Distribution Blocks (A) Overcurrent Protection: Each autotransformer 600 volts, nominal, or less shall be protected by an individual overcurrent device installed in series with each ungrounded input conductor. Such overcurrent device shall be rated or set at not more than 125 percent of the rated full-load input current of the autotransformer. Where this calculation does not correspond to a standard rating of a fuse or nonadjustable circuit breaker and the rated input current is 9 amperes or more, the next higher standard rating described in 240.6 shall be permitted. An overcurrent device shall not be installed in series with the shunt winding (the winding common to both the input and the output circuits) of the autotransformer between Points A and B as shown in Exhibit 450.6 (below). Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Courtesy of NFPA, from 2008 Handbook Power Supplies Exhibit 450.6 provides an example of overcurrent protection for an autotransformer. It shows a two-winding, single-phase transformer connected to boost a 208-volt supply to 240 volts. The autotransformer is provided with a two-pole disconnect switch with both overcurrent devices (OC-1a and OC-1b) located on the supply side of the autotransformer. DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) www.automationdirect.com/power-transformers Transformers eTX-29 Prices as of April 16, 2014. Check Web site for most current prices. Buck-Boost Transformer Selection Information How to select the proper transformer To select the proper transformer for buck-boost applications, determine the following first: Line Voltage The voltage that you want to buck (decrease) or boost (increase). This can be found by measuring the supply line voltage with a voltmeter. Load Voltage The voltage at which your equipment is designed to operate. This is listed on the nameplate of the load equipment. Load kVA or load Amps You do not need to know both. One is sufficient for selection purposes. This information usually can be found on the nameplate of the equipment that you want to operate. Supply Line and Equipment Frequencies The supply line frequency must be the same as the frequency of the equipment to be operated. This will be 60 Hz for buck-boost transformers. Number of Phases Single-phase or three-phase line and load should match because a transformer is not capable of converting single-phase to three-phase. The Type of Electrical Configuration Delta or Wye. How to use the selection charts on the following pages Example: (Assume the following information) 1. Find the appropriate single-phase, three-phase delta or three-phase wye table. 2. Read across the appropriate input/output voltage rows and find the nearest ratio of required load voltage to line voltage for the application desired. (High voltage (HV) and low voltage (LV) may be either input or output voltage depending on the circumstances.) 3. Reading vertically down the column beginning with your application voltage ratio, locate in one of the kVA rows a kVA capacity equal to or larger than your load requirement. 4. Now move left across the kVA row to locate the appropriate transformer catalog number for your application. 1. A reasonably constant line voltage of 200 volts. 2. A required equipment voltage of 236 volts. 3. 1.6 kVA load capacity needed. 4. Single-phase line and equipment. In the voltage rows, 208 is closest to our line voltage of 200. The 236 high voltage meets our requirements. Reading vertically down this column, find 1.8 kVA, the closest larger kVA to our required 1.6 load kVA. Moving left across this row, you will find the transformer catalog number to be 416-1221-000. Book 3 (14.1) eTX-30 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. Buck-Boost Single-Phase Selection Chart Terminal Blocks Single-Phase Connection Part Number 416-1100-000 416-1101-000 416-1111-000 416-1121-000 416-1131-000 416-1141-000 416-1151-000 416-1161-000 416-1171-000 Input or Output LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps Wiring Diagram Input or Part Number Output LV Amps 416-1201-000 HV Amps LV Amps 416-1211-000 HV Amps LV Amps 416-1221-000 HV Amps LV Amps 416-1231-000 HV Amps LV Amps 416-1241-000 HV Amps LV Amps 416-1251-000 HV Amps LV Amps 416-1261-000 HV Amps LV Amps 416-1271-000 HV Amps Wiring Diagram LV HV kVA kVA kVA kVA kVA kVA kVA kVA kVA LV HV kVA kVA kVA kVA kVA kVA kVA kVA Company Information 100 120 109 120 120 132 120 144 208 230 218 240 240 252 240 264 2.5 0.3 2.1 5.0 0.5 4.2 7.5 0.8 6.3 12.5 1.3 10.4 25.0 2.5 20.8 37.5 3.8 31.3 50.0 5.0 42.0 75.0 7.5 63.0 100.0 10.0 83.0 2 4.6 0.5 4.2 9.2 1.0 8.3 13.8 1.5 12.5 22.9 2.5 20.8 45.8 5.0 41.7 68.8 7.5 62.5 92.0 10.0 83.0 138.0 15.0 125.0 183.0 22.0 167.0 1 4.6 0.6 4.2 9.2 1.1 8.3 13.8 1.7 12.5 22.9 2.8 20.8 45.8 5.5 41.7 68.8 8.3 62.5 92.0 11.0 83.0 138.0 16.5 125.0 183.0 22.0 167.0 1 2.5 0.3 2.1 5.0 0.6 4.2 7.5 0.9 6.3 12.5 1.5 10.4 25.0 3.0 20.8 37.5 4.5 31.3 50.0 6.0 42.0 75.0 9.0 63.0 100.0 12.0 83.0 2 2.3 0.5 2.1 4.6 1.0 4.2 6.9 1.4 6.3 11.5 2.4 10.4 22.9 4.8 20.8 34.4 7.2 31.3 46.0 9.5 42.0 69.0 14.3 63.0 92.0 19.1 83.0 4 2.3 0.5 2.1 4.6 1.0 4.2 6.9 1.5 6.3 11.5 2.5 10.4 22.9 5.0 20.8 34.4 7.5 31.3 46.0 10.0 42.0 69.0 15.0 63.0 92.0 20.0 83.0 4 4.4 1.1 4.2 8.8 2.1 8.3 13.1 3.2 12.5 21.9 5.3 20.8 43.8 10.5 41.7 65.6 15.8 62.5 88.0 21.0 83.0 131.0 31.5 125.0 175.0 42.0 167.0 3 2.3 0.6 2.1 4.6 1.1 4.2 6.9 1.7 6.3 11.5 2.8 10.4 22.9 5.5 20.8 34.4 8.3 31.3 46.0 11.0 42.0 69.0 16.5 63.0 92.0 22.0 83.0 4 95 120 106 120 120 136 120 152 208 236 212 240 225 240 240 272 4.0 0.4 3.1 5.9 0.6 4.7 9.9 0.9 7.8 19.8 1.9 15.6 29.7 2.8 23.4 40.0 3.8 31.0 59.0 5.6 47.0 79.0 7.5 63.0 7.1 0.8 6.3 10.6 1.1 9.4 17.7 1.9 15.6 35.4 3.8 31.3 53.1 5.6 46.9 71.0 7.5 63.0 106.0 11.3 94.0 142.0 15.0 125.0 7.1 0.9 6.3 10.6 1.3 9.4 17.7 2.1 15.6 35.4 4.3 31.3 53.1 6.4 46.9 71.0 8.5 63.0 106.0 12.8 94.0 142 17.0 125.0 4.0 0.5 3.1 5.9 0.7 4.7 9.9 1.2 7.8 19.8 2.4 15.6 29.7 3.6 23.4 40.0 4.8 31.0 59.0 7.1 47.0 79 9.5 63.0 3.5 0.7 3.1 5.3 1.1 4.7 8.9 1.8 7.8 17.7 3.7 15.6 26.6 5.5 23.4 35.0 7.4 31.0 53.0 11.1 47.0 71.0 14.7 63.0 3.5 0.8 3.1 5.3 1.1 4.7 8.9 1.9 7.8 17.7 3.8 15.6 26.6 5.6 23.4 35.0 7.5 31.0 53.0 11.3 47.0 71.0 15.0 63.0 6.7 1.5 6.3 10.0 2.3 9.4 16.7 3.8 15.6 33.3 7.5 31.3 50.0 11.3 46.9 67.0 15.0 63.0 100.0 22.5 94.0 133.0 30.0 125.0 3.5 0.9 3.1 5.3 1.3 4.7 8.9 2.1 7.8 17.7 4.3 15.6 26.6 6.4 23.4 35.0 8.5 31.0 53.0 12.8 47.0 71.0 17.0 63.0 2 1 1 2 4 4 3 4 Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) www.automationdirect.com/power-transformers Transformers eTX-31 Prices as of April 16, 2014. Check Web site for most current prices. Buck-Boost 3-Phase Open Delta Selection Chart Please note: Three-phase open delta connections require two transformers. Three-Phase Open Delta Connection Part Number Input or Output LV HV LV Amps kVA 416-1100-000 HV Amps LV Amps 416-1101-000 kVA HV Amps LV Amps 416-1111-000 kVA HV Amps LV Amps 416-1121-000 kVA 2.3 2.3 4.4 4.4 2.3 0.8 0.9 1.7 1.8 1.0 2.1 2.1 4.2 4.2 2.1 4.6 4.6 8.8 8.8 4.6 1.7 1.7 3.5 3.6 1.9 4.2 4.2 8.3 8.3 4.2 6.9 6.9 13.1 13.1 6.9 2.5 2.6 5.2 5.5 2.9 6.3 6.3 12.5 12.5 6.3 11.5 11.5 21.9 21.9 11.5 8.7 9.1 4.8 20.8 20.8 10.4 22.9 22.9 43.8 43.8 22.9 8.3 8.7 17.4 18.2 9.5 20.8 20.8 41.7 41.7 20.8 34.4 34.4 65.6 65.6 34.4 12.4 13.0 26.0 27.3 14.3 31.3 31.3 62.5 62.5 31.3 46.0 46.0 88.0 88.0 46.0 kVA 16.5 17.3 34.7 36.4 19.1 42.0 42.0 83.0 83.0 42.0 69.0 69.0 131.0 131.0 69.0 kVA 24.8 26.0 52.1 54.6 28.6 63.0 63.0 125.0 125.0 63.0 HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps 416-1171-000 240 264 4.3 kVA 416-1161-000 240 252 10.4 HV Amps LV Amps 416-1151-000 229 240 4.1 kVA 416-1141-000 218 240 10.4 HV Amps LV Amps 416-1131-000 208 230 92.0 92.0 175.0 175.0 92.0 kVA 33.0 34.6 69.4 72.7 38.1 83.0 83.0 167.0 167.0 83.0 10 10 9 9 10 HV Amps Wiring Diagram Part Number Input or Output LV HV LV Amps kVA 416-1201-000 HV Amps LV Amps 416-1211-000 kVA HV Amps LV Amps 416-1221-000 kVA HV Amps LV Amps 416-1231-000 kVA HV Amps LV Amps 416-1271-000 HV Amps Wiring Diagram 3.5 3.5 6.7 3.5 1.3 1.3 2.6 1.5 3.1 3.1 6.3 3.1 5.3 5.3 10.0 5.3 1.9 2.0 3.9 2.2 4.7 4.7 9.4 4.7 8.9 8.9 16.7 8.9 3.2 3.3 6.5 3.7 7.8 7.8 15.6 7.8 17.7 17.7 33.3 17.7 6.5 13.0 7.4 31.3 15.6 26.6 26.6 50.0 26.6 9.6 9.8 19.5 11.0 23.4 23.4 46.9 23.4 35.0 35.0 67.0 35.0 12.8 13.0 26.0 14.7 31.0 31.0 63.0 31.0 53.0 53.0 100.0 53.0 kVA 19.1 19.5 39.0 22.1 47.0 47.0 94.0 47.0 71.0 71.0 133.0 71.0 kVA 25.5 26.0 52.0 29.4 63.0 63.0 125.0 63.0 10 10 9 10 kVA 416-1261-000 240 272 15.6 HV Amps LV Amps HV Amps LV Amps 225 240 6.4 kVA 416-1251-000 212 240 15.6 HV Amps LV Amps 416-1241-000 208 236 Book 3 (14.1) eTX-32 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. Buck-Boost 3-Phase Wye Selection Chart Terminal Blocks Please note: Three-phase wye delta connections require three transformers. Power Distribution Blocks Three-Phase Wye Connection Part Number 416-1100-000 416-1101-000 416-1111-000 416-1121-000 416-1131-000 416-1141-000 416-1151-000 416-1161-000 416-1171-000 Input or Output LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps Wiring Diagram Part Number 416-1201-000 416-1211-000 416-1221-000 416-1231-000 416-1241-000 416-1251-000 416-1261-000 416-1271-000 Input or Output LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps LV Amps HV Amps Wiring Diagram LV HV kVA kVA kVA kVA kVA kVA kVA kVA kVA LV HV kVA kVA kVA kVA kVA kVA kVA kVA Company Information 173 208 189 208 208 229 208 249 378 416 397 416 416 437 416 457 2.5 0.7 2.1 5.0 1.5 4.2 7.5 2.2 6.3 12.5 3.7 10.4 25.0 7.5 20.8 37.5 11.2 31.3 50.0 15.0 42.0 75.0 22.5 63.0 100.0 30.0 83.0 6 1.8 0.6 1.6 3.5 1.2 3.1 13.8 4.5 12.5 22.9 7.5 20.8 45.8 15.0 41.7 68.8 22.5 62.5 92.0 30.0 83.0 138.0 45.0 125.0 183.0 60.0 167.0 5 4.6 1.7 4.2 9.2 3.3 8.3 13.8 5.0 12.5 22.9 8.3 20.8 45.8 16.5 41.7 68.8 24.8 62.5 92.0 33.0 83.0 138.0 49.5 125.0 183.0 66.0 167.0 5 2.5 0.9 2.1 5.0 1.8 4.2 7.5 2.7 6.3 12.5 4.5 10.4 25.0 9.0 20.8 37.5 13.5 31.3 50.0 18.0 42.0 75.0 27.0 63.0 100.0 36.0 83.0 6 2.3 1.5 2.1 4.6 3.0 4.2 6.9 4.5 6.3 11.5 7.5 10.4 22.9 15.0 20.8 34.4 22.5 31.3 46.0 30.0 42.0 69.0 45.0 63.0 92.0 60.0 83.0 8 4.4 3.0 4.2 8.8 6.0 8.3 13.1 9.0 12.5 21.9 15.0 20.8 43.8 30.1 41.7 65.6 45.1 62.5 88.0 60.2 83.0 131.0 90.2 125.0 175.0 120.3 167.0 7 4.4 3.2 4.2 8.8 6.3 8.3 13.1 9.5 12.5 21.9 15.8 20.8 43.8 31.5 41.7 65.6 47.3 62.5 88.0 63.0 83.0 131.0 94.6 125.0 175.0 126.0 167.0 7 2.3 1.7 2.1 4.6 3.3 4.2 6.9 5.0 6.3 11.5 8.3 10.4 22.9 16.5 20.8 34.4 24.8 31.3 46.0 33.0 42.0 69.0 49.5 63.0 92.0 66.0 83.0 8 164 208 183 208 208 235 208 263 367 416 390 416 416 443 416 471 Transformers and Filters 4.0 1.1 3.1 5.9 1.7 4.7 9.9 2.8 7.8 19.8 5.6 15.6 29.7 8.4 23.4 40.0 11.2 31.0 59.0 16.9 47.0 79.0 22.5 63.0 6 7.1 2.2 6.3 10.6 3.4 9.4 17.7 5.6 15.6 35.4 11.2 31.3 53.1 16.8 46.9 71.0 22.5 63.0 106.0 33.7 94.0 142.0 44.9 125.0 5 7.1 2.6 6.3 10.6 3.8 9.4 17.7 6.4 15.6 35.4 12.8 31.3 53.1 19.1 46.9 71.0 25.5 63.0 106.0 38.3 94.0 142.0 51.0 125.0 5 4.0 1.4 3.1 5.9 2.1 4.7 9.9 3.6 7.8 19.8 7.1 15.6 29.7 10.7 23.4 40.0 14.3 31.0 59.0 21.4 47.0 79.0 28.5 63.0 6 3.5 2.3 3.1 5.3 3.4 4.7 8.9 5.6 7.8 17.7 11.3 15.6 26.6 16.9 23.4 35.0 22.5 31.0 53.0 33.8 47.0 71.0 45.0 63.0 8 6.7 4.5 6.3 10.0 6.8 9.4 16.7 11.3 15.6 33.3 22.5 31.3 50.0 33.8 46.9 67.0 45.0 63.0 100.0 67.5 94.0 133.0 90.1 125.0 7 6.7 4.8 6.3 10.0 7.2 9.4 16.7 12.0 15.6 33.3 24.0 31.3 50.0 36.0 46.9 67.0 48.0 63.0 100.00 72.1 94.0 133.0 96.1 125.0 7 3.5 2.6 3.1 5.3 3.8 4.7 8.9 6.4 7.8 17.7 12.8 15.6 26.6 19.1 23.4 35.0 25.5 31.0 53.0 38.3 47.0 71.0 51.0 63.0 8 Circuit Protection ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) www.automationdirect.com/power-transformers Transformers Wiring Accessories eTX-33 Prices as of April 16, 2014. Check Web site for most current prices. Buck-Boost Wiring Diagrams Wiring Diagram 1 Wiring Diagram 2 Wiring Diagram 3 Wiring Diagram 4 Wiring Diagram 5 Wiring Diagram 6 Wiring Diagram 7 Wiring Diagram 8 Wiring Diagram 9 Wiring Diagram 10 Book 3 (14.1) eTX-34 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. Buck-Boost Transformers General Specifications and Terminations Company Information Terminal Blocks Power Distribution Blocks 120 x 240 V - 16/32 V 60 Hz 120 x 240 V - 12/24 V 60 Hz Single-Phase - 600V Class Transformers General Specifications Termination HV LV Height (in.) Width (in.) Depth (in.) Shipping Weight (lbs.) Price 416-1100-000 #18 AWG Leads #18 AWG Leads 8.03 3.31 3.08 4.4 $53.00 416-1101-000 #18 AWG Leads #18 AWG Leads 8.03 3.31 3.08 4.8 $62.00 #18 AWG Leads #18 AWG Leads 8.03 3.31 3.08 5.6 $63.00 #18 AWG Leads #14 AWG Leads 8.03 3.31 3.08 6.7 $69.00 416-1131-000 #18 AWG Leads #10 AWG Leads 10.19 5.06 4.59 15.0 $98.00 0.75 416-1141-000 #18 AWG Leads #8 AWG Leads 10.19 5.06 4.59 17.0 $101.00 1 416-1151-000 #18 AWG Leads #8 AWG Leads 10.19 5.06 4.59 19.5 $124.00 1.5 416-1161-000 #18 AWG Leads #6 AWG Leads 12.50 6.69 5.34 35.0 $167.00 2 416-1171-000 #16 AWG Leads #4 AWG Leads 12.50 6.69 5.34 41.2 $229.00 KVA Part Number Width (in.) Depth (in.) Shipping Weight (lbs.) Price 0.10 0.15 0.25 416-1221-000 0.50 416-1231-000 0.75 KVA Part Number 0.05 0.10 0.15 416-1111-000 0.25 416-1121-000 0.50 Temp. Rise °C Wiring Accessories 95 135 Temp. Rise °C Termination ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties HV LV Height (in.) 416-1201-000 #18 AWG Leads #18 AWG Leads 8.03 3.31 3.08 4.8 $55.00 416-1211-000 #18 AWG Leads #18 AWG Leads 8.03 3.31 3.08 5.6 $58.00 #18 AWG Leads #14 AWG Leads 8.03 3.31 3.08 6.7 $63.00 Multi-conductor Flex Cable #18 AWG Leads #10 AWG Leads 10.19 5.06 4.59 15.0 $91.00 Data Cables 416-1241-000 #18 AWG Leads #10 AWG Leads 10.19 5.06 4.59 17.0 $101.00 1 416-1251-000 #18 AWG Leads #8 AWG Leads 10.19 5.06 4.59 19.5 $125.00 1.5 416-1261-000 #18 AWG Leads #6 AWG Leads 12.50 6.69 5.34 35.0 $164.00 2 416-1271-000 #16 AWG Leads #6 AWG Leads 12.50 6.69 5.34 41.2 $203.00 95 135 Wire Flexible Cord Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.1) www.automationdirect.com/power-transformers Transformers eTX-35 Prices as of April 16, 2014. Check Web site for most current prices. Buck-Boost Transformer Connections Used as an Isolation Transformer Maximum Secondary Current KVA Part Number 0.05 2 416-1100-000 416-1101-000 416-1111-000 416-1121-000 416-1131-000 416-1141-000 416-1151-000 416-1161-000 416-1171-000 KVA Part Number 0.10 416-1201-000 416-1211-000 416-1221-000 416-1231-000 416-1241-000 416-1251-000 416-1261-000 416-1271-000 0.10 0.15 0.25 0.50 0.75 1 1.5 0.15 0.25 0.50 0.75 1 1.5 2 Maximum Secondary Amperage 12V 24V 4.16 2.08 8.33 4.16 12.5 6.25 20.8 10.4 41.6 20.8 62.5 31.2 83.3 41.6 125 62.5 166.6 83.3 Maximum Secondary Amperage 16V 32V 6.25 3.12 9.38 4.69 15.6 7.81 31.2 15.6 46.8 23.4 62.5 31.2 93.7 46.8 125 62.5 Isolation Transformer Connections Connections Primary Volts Interconnect Primary Lines to Connect to 240 H2 to H3 H1-H4 H1 to H3 120 H2 to H4 Secondary Volts 24 32 12 16 H1-H4 Interconnect Primary Lines to Connect to X2 to X3 X1-X4 X1 to X3 X2 to X4 X1-X4 Book 3 (14.1) eTX-36 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. Dimensional Diagrams Company Information Terminal Blocks Housing Dimensions Inches (mm) Part Numbers A B C D E F G H I J 416-1100-000 416-1101-000 416-1111-000 416-1121-000 416-1201-000 416-1211-000 416-1221-000 416-1131-000 416-1141-000 416-1151-000 416-1231-000 416-1241-000 416-1251-000 8.03 (203.96) 10.19 (258.83) 3.31 (80.07) 5.06 (128.52) 3.08 (78.23) 4.56 (115.82) 6.81 (172.97) 9.06 (230.12) 6.19 (157.23) 8.38 (212.85) 2.25 (57.15) 2.25 (57.15) 1.00 (25.4) 1.00 (25.4) 1/2” (12.7) 1/2” (12.7) & 3/4” (19.05) 1.00 (25.4) 1.25 (31.75) 1.50 (38.1) 1.50 (38.1) Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Housing Dimensions Inches (mm) Part Numbers A B C D E F G H1 H2 I J K 416-1161-000 416-1171-000 Test Equipment 416-1261-000 416-1271-000 12.50 (317.5) 6.69 (169.93) Safety: Protective Wear 5.34 (135.64) 10.56 (268.22) Terms and Conditions 12.00 (304.8) 2.25 (57.15) 1.50 (38.1) 3/4” (19.05) & 1” (25.4) 1/2” (12.7) & 3/4” (19.05) 1/2” (12.7) & 3/4” (19.05) 1/2” (12.7) & 3/4” (19.05) 3.5 (88.9) 1.50 (38.1) 1.50 (38.1) Transformers Enclosure Climate Control Safety: Electrical Components Book 3 (14.1) www.automationdirect.com/power-transformers Enclosures eTX-37 Prices as of April 16, 2014. Check Web site for most current prices. Buck-Boost Transformer Cross-reference Automation Direct 416-1100-000 416-1101-000 416-1111-000 416-1121-000 416-1131-000 416-1141-000 416-1151-000 416-1161-000 416-1171-000 416-1201-000 416-1211-000 416-1221-000 416-1231-000 416-1241-000 416-1251-000 416-1261-000 416-1271-000 Sola-Hevi Duty Cuttler Hammer 9T51B0102 HS19B50 S10N04A81N 9T51B0104 HS19B100 S10N04A82N J150A1EA1A01 9T51B0105 HS19B150 S10N04A83N 205BB1224 J250A1EA1A02 9T51B0107 HS19B250 S10N04A26N 500SV43B 505BB1224 J500A1EA1A02 9T51B0108 HS19F500B S10N04A51N 750SV43F 705BB1224 J750A1EA1A02 9T51B0109 HS19F750B S10N04A76N SB12N1F 1S43F 1BB1224 J001K1EA1A02 9T51B0110 HS19F1B S10N04A01N SB12N1.5F 1.5S43F 105BB1224 J1X5K1EA1A02 9T51B0111 HS19F1.5A S10N04A16N Hammond Acme Federal QC05ERCB T1-81047 SB12N.050F QC10ERCB T1-81048 SB12N.100F QC15ERCB T1-81049 SB12N.150F QC25ERCB T1-81050 QC50ERCB QC75ERCB Square D Siemens Micron GE 50SV43A 050BB1224 J050A1EA1A01 100SV43A 100BB1224 J100A1EA1A01 150SV43A 150BB1224 SB12N.250F 250SV43B T1-81051 SB12N.500F T1-81052 SB12N.750F Q1C0ERCB T1-11683 Q1C5ERCF T1-11684 Q002ERCF T-1-11685 SB12N2F 2S43F 2BB1224 J002K1EA1A02 9T51B0112 HS19F2A S10N04A02N QC10ESCB T-1-81055 SB16N.100F 100SV46A 100BB1632 J100A1EB1A01 9T51B0124 HS20B100 S10N06A82N QC15ESCB T-1-81056 SB16N.150F 150SV46A 150BB1632 J150A1EB1A01 9T51B0125 HS20B150 S10N06A83N QC25ESCB T1-81057 SB16N.250F 250SV46B 205BB1632 J250A1EB1A02 9T51B0127 HS20B250 S10N06A26N QC50ESCB T1-81058 SB16N.500F 500SV46B 505BB1632 J500A1EB1A02 9T51B0128 HS20F500B S10N06A51N QC75ESCB T1-81059 SB16N.750F 750SV46F 705BB1632 J750A1EB1A02 9T51B0129 HS20F750B S10N06A76N Q1C0ESCB T1-13073 SB16N1F 1S46F 1BB1632 J001K1EB1A02 9T51B0130 HS20F1B S10N06A01N Q1C5ESCF T1-13074 SB16N1.5F 1.5S46F 105BB1632 J1X5K1EB1A02 9T51B0131 HS20F1.5A S10N06A16N Q002ESCF T-1-13075 SB16N2F 2S46F 2BB1632 J002K1EB1A02 9T51B0132 HS20F2A S10N06A02N Note: All cross reference results are to the best of our knowledge. Please compare and verify all product specifications before selecting. Book 3 (14.1) eTX-38 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. AEGIS Powerline Filters Company Information Terminal Blocks The AEGIS Series Powerline filters/surge protectors are specifically designed to protect against the full spectrum of transient disturbances and are engineered to filter the entire sine wave. The Powerline filters are designed to react instantly to changes in voltage regardless of phase angle or polarity. As a result, AEGIS devices are effective against both low- and high-energy transients to prevent immediate equipment damage and failure of sensitve electronic equipment over time. Select the hybrid (ADPH) when the equipment value is the higher or the highest level of RFI/EMI protection is required. Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors Features • Compact design • DIN rail included 35 mm • Meets latest UL safety standards for SPD (surge protective device) and EMI filtering protection • Contains no replaceable parts or items that require periodic maintenance • Alarm contact available (ADPH series only) • 10-year warranty Part Number • UL1449 3rd Ed – Type 2 SPD ADPV12001 Applications • Process control systems • Operator interface stations • Programmable logic controllers (PLCs) • Scanning devices • Automatic teller machines (ATMs) • Cash registers • Alarm systems •Robotics • Control equipment • CAD/CAM systems Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors ADPH12010 Wiring Duct AEGIS Powerline Filters Description Price 120VAC input, 1A w/LED $190.00 ADPV12003 120VAC input, 3A w/LED $219.00 ADPV12005 120VAC input, 5A w/LED $253.00 ADPV24001 240VAC input, 1A w/LED $200.00 ADPV24003 240VAC input, 3A w/LED $229.00 ADPV24005 240VAC input, 5A w/LED $263.00 ADPH12010 Hybrid filter, 120VAC input, 10A w/LED and alarm contacts $399.00 ADPH12015 Hybrid filter, 120VAC input, 15A w/LED and alarm contacts $530.00 ADPH24010 Hybrid filter, 240VAC input, 10A w/LED and alarm contacts $409.00 ADPH24015 Hybrid filter, 240VAC input, 15A w/LED and alarm contacts $539.00 Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Standards and Certifications Tools • • • • • • cURus E316410 CSA 163545 UL 1449 Third Edition UL 1283 Fifth Edition Built in an ISO 9001 facility Designed and tested in accordance with: – IEEE C62.41.1 – IEEE C62.41.2 – IEEE C62.43-2005 – IEEE C62.45-2002 – IEEE C62.48-2005 – IEEE C62.62-2010 • RoHS compliant Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions ADPV12003 Book 3 (14.1) www.automationdirect.com/power-transformers Cable Ties Transformers eTX-39 Prices as of April 16, 2014. Check Web site for most current prices. AEGIS Powerline Filters Technical Specifications AEGIS Powerline Filters Technical Specifications ADPH120xx ADPH240xx ADPV120xx ADPV240xx 100-127 VAC 200-240 VAC 100-127 VAC 200-240 VAC Input voltage range Amperage Frequency Protection modes Max continuous operations voltage (MCOV) EMI/RFI filtering attenuation Filter bandwidth Peak surge current per phase/mode UL nominal discharge current (VPR) UL voltage protection rating L-N / L-G / N-G Operating temperature Response time Status indicator Alarm contacts SCCR Product weight 10A, 15A 50/60 Hz L-N, L-G, N-G 1A, 3A, 5A 50/60 Hz L-N, L-G, N-G 150V 275V 75dB at 110kHz 10kHz to 100MHz 60/30 kA 5kA 400/330/330 700/600/600 -40°C to + 50°C [-40°F to 122°F] < 1 nanosecond LED Yes (form C) 5kA 1.77 lb [0.80 kg] 150V 275V 50dB at 100kHz 10kHz to 100MHz 40/20 kA 5kA 400/330/330 700/600/600 -40°C to + 50°C [-40°F to 122°F] < 1 nanosecond LED No 5kA 1.15 lb [0.52 kg] 22-10 AWG stranded copper for input/output terminals 22-10 AWG stranded copper for input/output terminals Wire gauge range 30-18 AWG stranded/solid copper alarm contacts – 9 lb·in [1.02 N·m] for input/output terminals 9 lb·in [1.02 N·m] for input/output terminals Torque Specs Environment protection ratings Component Material Type Alarm contact ratings* Input/output terminal size range for ferrules and ring/fork Alarm contacts terminal size range for ferrules and ring/fork terminals Mounting 4 lb·in [0.45 N·m] alarm contacts terminals – NEMA 1 NEMA 1 Plastic enclosure, type 950, rated UL94 V-0 8A @ 250VAC / 30VDC Plastic enclosure, type 950, rated UL94 V-0 – #6 stud size, 1/4” OD max #4 stud size, 3/16” OD max – (35 mm) DIN rail mountable. No mounting orientation restrictions. *Alarm contact and LED activation indicates power at output terminals. Maximum EMI/RFI Attenuation – MIL-STD-220 Model ADPH120xx ADPV120xx 10kHz 100kHz 1MHz 10MHz 30dB 27dB 74dB 56dB 76dB 55dB 37dB 36dB 100MHz Max Attenuation Frequency 36dB 28dB 101dB at 0.5 MHz 66dB at 0.085 MHz Let-Through Voltages Based on IEEE Std. C62.62-2010 Testing Waveforms Model ADPH120xx ADPV120xx 25V 35V 360V 30V 40V 370V IEEE Category A, 100kHz ring wave, 6000V, 200A IEEE Category B, 100kHz ring wave, 6000V, 500A IEEE Category B, 100kHz ring wave, 6000V, 3000A (UL 1449-3 VPR) Note: All tests conducted on 120VAC units only. Three-wire design has normal and common mode protection (L-N, L-G, N-G) Power Input L Primary Surge Protection High High Series Frequency Blocking Performance Capacitor Inductors Tracking Filter Secondary Surge Protection Optional Form C Contacts* Power Output Normal Mode Normal Mode N G Status Indicator Lights LED Form C L N Common Mode Common Mode * Available on the series *Available onPHthe PHonly. series G only. Book 3 (14.1) eTX-40 Transformers 1-800-633-0405 Prices as of April 16, 2014. Check Web site for most current prices. AEGIS Powerline Filters Company Information Terminal Blocks Dimensions in [mm] Power Distribution Blocks Wiring Accessories ADPH ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable ADPV Data Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosures See our website: www.AutomationDirect.com for complete engineering drawings Enclosure Climate Control Wiring Diagram Safety: Electrical Components Safety: Protective Wear L LINE INPUT FROM SOURCE N GND Terms and Conditions L RELAY CONTACTS NO COM NC TO LOAD OR PROTECTED EQUIPMENT N GND REMOTE INDICATION (ADPH MODEL ONLY) Book 3 (14.1) www.automationdirect.com/power-transformers Transformers eTX-41 Prices as of April 16, 2014. Check Web site for most current prices. Convenience Outlet The hard way The convenient way Need power in your panel? Have you ever needed to plug in your laptop or oscilloscope at the control enclosure only to find there was no outlet available? Our customers asked us for a solution to this problem. We turned to our friends at FACTS Engineering for help. To install the FA-REC3 outlet, snap the outlet on the DIN rail, terminate three wires, and that’s it! It doesn’t get much more convenient than that. Practically every enclosure installed these days has DIN rail incorporated into the control design. Instead of buying metallic boxes, covers, outlets, and strain reliefs, why not just install one of our convenience outlets? Specifications • Output voltage:125VAC • Outlet type:NEMA 5-15R • Output current:15A maximum • Total current:Must not exceed 15A if all outlets are used • GFCI:None • Mounting:35mm DIN rail • Wire capacity:14 to 12 AWG • Tightening torque:6 in-lbs. • Operating temp.:0 to 60° C (32 to 140°F) • Circuit protection:None • UL 508 listed FA-REC3 $22.00 Book 3 (14.1) eTX-42 Transformers 1-800-633-0405