Rechargeable Sealed Lead-Acid Batteries

advertisement
Rechargeable Sealed Lead-Acid Batteries
Model
PS-260
PS-445
PS-490
PS-4100
PS-605
PS-610
PS-612
PS-628
PS-630
PS-632
PS-640
PS-650L
PS-665
PS-670
PS-682
PS-6100
PS-6120
PS-6120 Toy
PS-6200
PS-6360
PS-832
PS-1208
PS-1212
PS-1220
PS-1221S
PS-1223
PS-1228
PS-1229
PS-1230
PS-1250
PS-1251FP
PSH-1255
PS-1270
PSH-1280
PS-1282
PS-12100
PSH-12100
PS-12120
PS-12180
PSH-12180
PS-12260
PS-12280
PS-12330
PS-12400
PS-12550
PS-12750
PS-121000
PS-121100
PS-121400
Nominal
Voltage
V
2
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
Nominal
Capacity
A.H.
6.0
4.5
9.0
10.0
0.5
1.1
1.4
2.9
3.5
3.5
4.6
5.0
6.5
7.0
9.0
12.0
13.0
13.0
20.0
36.0
3.2
0.8
1.4
2.5
2.0
2.3
2.8
2.9
3.4
5.0
5.4
6.0
7.0
8.5
9.0
12.0
10.5
12.0
18.0
21.0
26.0
28.0
35.0
40.0
55.0
75.0
100.0
110.0
140.0
Current @
20 hr. rate
mA
300
225
450
500
25
55
70
145
175
175
230
250
325
350
450
600
650
650
1000
1800
160
40
70
125
100
115
140
145
170
250
270
24 Watts/Cell*
350
37 Watts/Cell*
450
600
41 Watts/Cell*
600
900
77 Watts/Cell*
1300
1400
1750
2000
2750
3750
5000
5500
7000
Length
in.
1.97
1.89
3.97
4.02
2.24
2.00
3.82
2.60
5.28
2.60
2.76
2.63
3.86
5.95
3.86
5.95
4.26
4.26
6.18
6.25
5.29
3.78
3.82
7.01
5.94
7.17
5.24
7.01
5.28
3.54
5.50
3.54
5.95
5.95
3.86
5.95
5.95
5.95
7.13
7.14
6.54
6.54
7.80
7.76
9.04
10.25
12.00
13.00
13.50
Width
mm
50
48
101
102
57
51
97
66
134
66
70
67
98
151
96
151
108
108
157
159
134
96
97
178
151
182
133
178
134
90
139.7
90
151
151
98
151
151
151
181
182
166
166
198
197
230
260
305
330
343
in.
1.34
2.09
1.73
1.97
0.55
1.65
0.94
1.30
1.34
1.30
1.86
2.63
2.20
1.34
2.20
2.00
2.795
2.795
3.27
3.35
1.42
0.98
1.69
1.38
0.79
0.94
1.30
1.34
2.64
2.76
1.89
2.76
2.56
2.56
4.40
4.00
2.56
3.86
3.00
3.03
6.88
4.95
5.20
6.50
5.45
6.60
6.60
6.76
6.75
Height
mm
34
53
44
50
14
42
24
33
34
33
47
67
56
34
56
51
71
71
83
85
36
25
43
35
20
24
33
34
67
70
48
70
65
65
112
102
65
98
76
77
175
126
132
165
138
168
168
172
171
in.
3.94
3.70
3.74
3.72
1.97
2.00
2.00
3.86
2.35
4.65
3.94
3.78
4.05
3.70
4.65
3.70
5.54
5.54
4.92
6.50
2.49
2.42
2.05
2.36
3.50
2.42
3.82
2.36
2.36
3.98
4.02
3.98
3.70
3.70
4.65
3.70
4.37
3.70
6.59
6.59
4.95
6.89
6.22
6.69
8.15
8.15
8.15
8.40
10.80
Ht. Over Terminal
mm
100
94
95
94.5
50
51
51
98
60
118
100
96
103
94
118
94
141
141
125
165
63
62
52
60
89
62
97
60
60
101
102
101
94
94
118
94
111
94
167
168
126
175
158
170
207
207
207
213
275
in.
4.13
3.86
4.02
3.92
1.97
2.20
2.19
4.06
2.56
4.80
4.25
4.28
4.06
3.94
4.65
3.86
5.54
5.54
4.92
6.95
2.70
2.42
2.28
2.56
3.50
2.42
4.09
2.56
2.60
4.21
4.06
4.21
3.86
3.86
4.65
3.86
4.61
3.94
6.59
6.59
4.95
6.89
7.07
6.69
8.98
8.98
8.98
8.70
11.15
mm
105
98
102
99.6
50
56
56
103
65
122
108
109
103
100
118
98
141
141
125
177
69
62
58
65
89
62
104
65
66
107
103
107
98
98
118
98
117
100
167
168
126
175
180
170
228
228
228
221
283
73
102
69
76
101
2.87
4.00
2.70
3.00
3.99
73
102
69
76
101
The PSG Series of batteries correspond in size to Hawker models of same voltage and capacity.
PSG-450
PSG-480
PSG-625
PSG-650
PSG-680
4
4
6
6
6
5.0
8.0
2.5
5.0
8.0
250
400
125
250
400
3.54
3.54
4.15
5.28
5.28
90
90
105
134
134
1.94
1.94
1.63
1.94
1.94
49
49
41
49
49
2.87
4.00
2.70
3.00
3.99
Weight
Standard
Terminals
lbs.
kgs.
0.86
0.39
F1
1.40
0.65
F2
2.50
1.14
F2
3.10
1.41
F1
0.20
0.09
WL
0.60
0.30
F1
0.60
0.30
F1
1.30
0.59
F1
1.37
0.62
F1
1.37
0.62
F1
1.80
0.82
F1
2.00
0.91
SP
2.10
0.95
FP
2.80
1.27
F1
3.35
1.52
F1
4.40
2.00
F1 or F2
5.30
2.40
FP
5.30
2.40
TS or TH
7.52
3.41
NB
13.70
6.20
F2 or NB
1.90
0.86
F1
0.80
0.36
WL
1.32
0.60
F1
2.20
1.00
F1
1.50
0.68
F1
1.68
0.76
PC
2.60
1.18
F1
2.60
1.18
F1
2.90
1.32
F1
3.75
1.70
F1 or F2
4.20
1.90
FP
4.19
1.90
F2
5.70
2.59
F1 or F2
6.00
2.72
F2
7.45
3.38
F1
8.80
4.00
F1
7.00
3.18
F2
8.50
3.86
F2
12.60
5.70
F2 or NB
13.30
6.00
NB
18.00
8.18
F2 or NB
21.40
9.70
NB
26.50
12.00
NB
30.50
13.80
NB
41.30
18.77
U
55.00
25.00
U
68.70
31.20
U
71.20
32.36
B
102.00
46.36
B
* Watts/cell @ 15 min. rate to 1.67V
1.70
2.50
1.50
2.50
3.70
0.77
1.14
0.68
1.14
1.68
F2
F2
F1
F2
F2
DISCHARGE CHARACTERISTICS
CHARGING
Cycle Applications: Limit initial current to 0.30C (C is the nominal
A.H. capacity of the battery). Charge until battery voltage (under
charge) reaches 2.45 volts per cell at 68°F (20°C). Hold at 2.45
volts per cell until current drops to approximately 0.01C amperes.
Battery is fully charged under these conditions, and charger
should be disconnected or switched to “float” voltage.
“Float” or “Stand-by” Service: Hold battery across constant
voltage source of 2.25 to 2.30 volts per cell continuously. When
held at this voltage, the battery will seek its own current level and
maintain itself in a fully charged condition.
TERMINALS
“F1”
Continuous over or undercharging is the single worst enemy of a
lead-acid battery. Caution should be exercised to insure that the
charger is disconnected after cycle charging, or that the float
voltage is set correctly.
Because there is a chance of off-gassing hydrogen and oxygen if
the battery is overcharged, it is important to provide adequate air
circulation.
Batteries should not be stored in a discharged state (or in a hot
place). If a battery has been discharged for some time it may not
readily take a charge. To over-come this, leave the charger
connected and the battery will eventually begin to accept a charge.
Due to the self-discharge characteristics of this type of battery, it is
imperative that they be charged after 6 months of storage at 2025ºC, otherwise permanent loss of capacity might occur as a result
of sulfation. To prolong shelf life without charging, store batteries at
50°F (10°C) or less.
Spring
0.187" x 0.032"
quick disconnect tabs.
“F2”
“SP”
Fully collapsible spring
terminals for positive
and negative contacts.
FASTON
0.250" x 0.032"
quick disconnect tabs.
“FP”
APPLICATION NOTES
FASTON
Universal
“U”
Universal automotive post
with nut & bolt ("NB")
terminal connectors
FASTON Polarized
Positive: “F2” Negative: “F1”
Button
“PC”
Pressure Contacts
“B”
Threaded copper
insert terminals
On PS-1223 battery.
“WL”
Insulated, stranded wire leads terminated with:
• Molex Housing 5264-02 & 5263-PBT plug on PS-605
• AMP Housing 1-480318-0 & 8116-1 on PS-1208
“TS/TH”
Toy battery connectors:
•
S-connector
6120 TS
•
H-connector
6120 TH
All data subject to change without notice.
AVAILABLE THROUGH
DC Battery Specialists
160 NW 73 St • Miami, FL 33150
Tel:305.758.5041 Fax:305.758.3469
e-mail: sales@dcbattery.com • www.dcbattery.com
ISO9001-2000
FM39170
03/05 5M