ABB
Analog signal converters
CC range
Content
Benefits and advantages.................................................................................................. 200
Application......................................................................................................................... 201
Approvals and marks........................................................................................................ 201
Ordering details
Analog standard signal converters
CC-E/STD, CC-E x/x....................................................................................................
CC-E I/I.........................................................................................................................
CC-U/STD.....................................................................................................................
CC-U/STDR..................................................................................................................
Temperature signal converters for RTD sensors
CC-E/RTD.....................................................................................................................
CC-U/RTD.....................................................................................................................
CC-U/RTDR..................................................................................................................
Temperature signal converters for thermocouples
CC-E/TC.......................................................................................................................
CC-U/TC.......................................................................................................................
CC-U/TCR.....................................................................................................................
Measuring converters for currents (E/I) and (U/I) and voltages (U/V)
CC-E/I...........................................................................................................................
CC-E IAC / ILPO.............................................................................................................
CC-U/I...........................................................................................................................
CC-U/V..........................................................................................................................
Accessories...................................................................................................................
Technical data
CC-E/STD, CC-E x/x, CC-E/RTD, CC-E/TC.................................................................
CC-E I/I.........................................................................................................................
CC-U/STD, CC-U/RTD, CC-U/TC................................................................................
CC-U/STDR, CC-U/RTDR, CC-UTCR..........................................................................
CC-E/I, CC-E IAC / ILPO................................................................................................
CC-U/I, CC-U/V............................................................................................................
Technical diagrams..............................................................................................................
Dimensional drawings.........................................................................................................
ABB
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
223
199
2CDC110004C0205
5
Analog signal converters
CC range
2CDC 285 001 F0b05
Benefits and advantages
CC-U range
CC-E range
J
J
J
J
J
J
J Universally configurable devices and single-function devices
8 different standard signal outputs on one device
Input and output side universally configurable
Also available with 2 threshold relay outputs
Adjustment and operating elements on the front side
Safe operation by electrical 3-way isolation
Plug-in connecting terminals, unambiguously and clearly marked
Conversion, measurement and separation of
J
J
J
J
standard signals
signals of RTD sensors (PT10, PT100, PT1000)
thermocouple signals
RMS values of currents and voltages
Characteristics
J The required input and output ranges can be configured for all devices by means of directly accessible DIP switches positioned
on the side.
J Due to the wide input range of the gain and offset stages all input
signals between the minimum and the maximum input value can be
universally converted to all common output signals.
J Devices for DC or AC (50/60 Hz) supply available.
J Adjustment and operating elements on the front side
J Safe operation by electrical 3-way isolation
J Unambiguous and clear connecting terminal markings
Conversion, measurement and separation of
J
J
J
J
standard signals (0-5 V, 0-10 V, 0-20 mA, 4-20 mA)
temperature signals of RTD sensors (PT 100)
thermocouple signals (types J and K)
current measurement signals (0-5 A, 0-20 A AC/DC)
Characteristics of single-function devices
J No adjustment or balancing necessary.
Characteristics of universal devices
J The required input and output ranges can be configured by means
of directly accessible DIP switches positioned on the side
J Gain adjustment of ± 5 % by means of an adjustment potentiometer on the front-side
J Offset adjustment of ±5 % by means of adjustment potentiometers on the front-side
2CDC 283 016 F0b03
5
Product range for analog signal processing
200
2CDC110004C0205
ABB
Analog signal converters
CC range
Application, Approvals and marks
Applications for analog signal processing and
correct solution using CC-E and CC-U converters
0-10 V
Nearly every process includes a control system that receives data by
means of analog signals and then evaluates the data and sets the respective parameters correspondingly.
0-10 V
Controller
e.g. AC500
1.
Analog signal converter
(e.g. CC-E or CC-U)
2.
Analog signal converter
(e.g. CC-E or CC-U)
When transmitting analog signals numerous problems may arise which
can disturb or even block an ideal behavior of the process.
100 m
0-20 mA
100 m
Below we have listed some processing problems together with the 4-20 mA
Actuator
respective solutions to solve these problems:
Measuring sensor
2CDC 282 013 F0206
Signal conversion
Sometimes the available signals cannot be processed by the controller
or the actuator. In this case, signal converters are required to convert
the input signal (or different input signals) to the desired output signal.
Signal amplification
Signal separation
If long lines or high burdens have to be operated, it may be necessary
to amplify the signal. CC analog signal converters require only low input power and provide high output power.
J Protection against overvoltage
The increased use of micro-electronics make controls much more
sensitive against overvoltages, resulting from lightning discharges
or switching processes. Suppression diodes are incorporated in
the input of the CC analog signal converters which enable the
converters to arrest overvoltages with low energy level (resulting
from switching processes) by themselves. The products furthermore provide electrical isolation between input, output and supply circuit for protection of the controller connected to the output.
Thus, there are no restrictions for the converter's position on the line,
i.e. it can be used
J for signal refreshing  at the end of the line (low input power)
J or for signal amplification  at the beginning of the line (high output power).
J Protection against ground loops
Signal filtering
If components are used which refer to ground, the measuring
signals can be falsified by a so-called ground loop. In this case,
Particularly on long lines or in rough industrial environments the signals
certain parts of the signal are transmitted via earth and not via the
are exposed to high electromagnetic interferences. The frequency of
analog transmission line, thus causing incorrect evaluation of the
the coupled interference signals may be in the range of the common
signal. The electrical isolation between the input and the output
mains frequency (50 Hz) or even much higher (in case of frequency
disconnects these ground loops and thus enables correct signal
converters). According to the specific requirements, analog signal
transmission.
converters are available which provide reliable suppression of those
interferences by means of an input low-pass filter.
J
J
J
G
J
J
J
J
A
UL 1604 (Class I, Div 2, hazardous locations),
CAN/CSA C22.2 No.213
G
K
CB scheme
J
J
J
E
CCC
J
J
J
J
CC-U/V
CC-E/I
J
UL 508, CAN/CSA C22.2 No.14
CC-U/I
CC-U/TCR
J
A
Approvals
CC-E IAC/ILPO
CC-U/TC
J
CC-E/TC
CC-U/RTD
G
CC-U/RTDR
CC-E/RTD
J
CC-U/STD
J
CC-E I/I
J
CC-E/STD
CC-U/STDR
J existing
G existing for some devices
j pending
J
J
J
J
J
G
Marks
a
CE
J
J
J
J
J
J
J
J
J
J
J
J
J
J
b
C-Tick
J
J
J
J
J
J
J
J
J
J
J
J
J
J
ABB
201
2CDC110004C0205
5
Analog standard signal converters
CC-E/STD, CC-E x/x
Ordering details
J 2 universally configurable devices (type CC-E/STD)
J 2x10 single-function devices
J "Plug and Work", no adjustment of single-function devices required
Wiring instruction
DIP switch settings (universal devices)
�
Input
�
0...5 V
Burden
R � 500 �
CC-E/STD
supply
24 V DC or 110-240 V AC
2CDC 282 006 F0206
Burden
R � 1.0 k�
�
0...10 V
0...20 mA
2CDC 281 014 F0t04
4...20 mA
Type
�
CC-E V/V
5
Input signal
Output
Switch
1 2 3 4 5 6 7 8
0...5 V
0...10 V
0...20 mA
4...20 mA
0...5 V
0...10 V
0...20 mA
4...20 mA
0...5 V
0...10 V
0...20 mA
4...20 mA
0...5 V
0...10 V
0...20 mA
4...20 mA
Output signal
Order code
Pack. unit
piece
0-5 V, 0-10 V
0-20 mA, 4-20 mA
1SVR 011 700 R00001)
1
Legend
ON
OFF
2CDC 282 002 F0204
�
2CDC 282 001 F0204
2CDC 281 001 F0t03
CC-E/STD analog signal converter with 3-way electrical isolation
Price
1 piece
Supply voltage: 24 V DC
universal
CC-E/STD
0-5 V, 0-10 V
0-20 mA, 4-20 mA
single-function
1 U: green LED -
supply voltage
2 Gain adjustment
3 Offset adjustment
 DIP switch for input and
output configuration (only available on universal devices)
CC-E V/V
CC-E V/I
CC-E V/I
0-10 V
0-10 V
0-20 mA
4-20 mA
1SVR 011 710 R2100
1SVR 011 711 R1600
1SVR 011 712 R1700
1
1
1
CC-E I/V
CC-E I/I
CC-E I/I
0-20 mA
0-10 V
0-20 mA
4-20 mA
1SVR 011 713 R1000
1SVR 011 714 R1100
1SVR 011 715 R1200
1
1
1
CC-E I/V
CC-E I/I
CC-E I/I
4-20 mA
0-10 V
0-20 mA
4-20 mA
1SVR 011 716 R1300
1SVR 011 717 R1400
1SVR 011 718 R2500
1
1
1
CC-E V/V
-10...+10 V
-10...+10 V
1SVR 011 719 R2600
1
0-5 V, 0-10 V
0-20 mA, 4-20 mA
1SVR 011 705 R2100
1
Supply voltage: 110-240 V AC
universal
CC-E/STD
0-5 V, 0-10 V
0-20 mA, 4-20 mA
single-function
B 1604 Class I, Div.2 (universal device)
CC-E V/V
CC-E V/I
CC-E V/I
0-10 V
0-10 V
0-20 mA
4-20 mA
1SVR 011 720 R2300
1SVR 011 721 R1000
1SVR 011 722 R1100
1
1
1
CC-E I/V
CC-E I/I
CC-E I/I
0-20 mA
0-10 V
0-20 mA
4-20 mA
1SVR 011 723 R1200
1SVR 011 724 R1300
1SVR 011 725 R1400
1
1
1
CC-E I/V
CC-E I/I
CC-E I/I
4-20 mA
0-10 V
0-20 mA
4-20 mA
1SVR 011 726 R1500
1SVR 011 727 R1600
1SVR 011 728 R2700
1
1
1
CC-E V/V
-10...+10 V
-10...+10 V
1SVR 011 729 R2000
1
1)
202
2CDC110004C0205
• Technical data .......................................................................... 217
• Dimensional drawings ...............................................................223
ABB
Current/current isolator
CC-E I/I-1 and CC-E I/I-2
2CDC 281 001 F0b06
Ordering details
Loop-powered current/current isolator without external power supply for analog current signals of 0-20 mA and 4-20 mA
J
J
J
J
Electrical isolation between input and output
Very low internal voltage drop  2.5 V
Available with one or two independent channels
Width only 18 mm (1 and 2 channels)
Wiring instructions
CC-E I/I-1
input
0-20 mA or
4-20 mA
Channel 1
IN
OUT
C
F
D
E
output
0-20 mA or
4-20 mA
UL
2CDC 281 041 F0b03
IN
OUT
100 � � RL � 500 �
2CDC 282 003 F0205
Channel 1
CC-E I/I-1
CC-E I/I-2
Channel 1
input
0-20 mA or
4-20 mA
Channel 1
IN
OUT
C
F
D
E
output
0-20 mA or
4-20 mA
UL
IN
OUT
100 � � RL � 500 �
input
0-20 mA or
4-20 mA
Chanel 2
IN
A
H
B
G
OUT
output
0-20 mA or
4-20 mA
UL
IN
OUT
100 � � RL � 500 �
Type
5
2CDC 282 004 F0205
CC-E I/I-2
Channel 2
Input signal
Output signal
Order code
Pack. unit
piece
0-20 mA, 4-20 mA
0-20 mA, 4-20 mA
1SVR 010 200 R1600
1
0-20 mA, 4-20 mA
0-20 mA, 4-20 mA
1SVR 010 201 R0300
1
Price
1 piece
1 channel
CC-E I/I-1
2 channel
CC-E I/I-2
• Technical data .......................................................................... 218
ABB
• Dimensional drawings ...............................................................223
203
2CDC110004C0205
Analog standard signal converter
CC-U/STD
Ordering details
2CDC 281 002 F0t03
CC-U/STD universal signal converter with 3-way electrical isolation
�
�
�
J
J
J
J
J
J
More than 120 configurations possible
Configurable output signal response on input voltage signal interruption (low fail safe / high fail safe)
Adjustment and operating elements on the front
Short-circuit proof signal outputs
Plug-in connecting terminals for inputs, outputs and supply
Very fast signal transmission enables use in control systems
�
�
Adjustment range
�
CC-U/STD
Continuously variable adjustment range:
Example ➀:
Input configuration:
0...10 V
Output configuration: -5...5 V
Wiring instruction
OUT [%]
100
Gain
“gain-coarse”
und
“gain-fine”
90
80
 Plug-in terminals
70
60
 Gain: Coarse adjustment
50
40
 Offset adjustment
 U: green LED -
supply voltage
30
Burden
R � 4.7 k�
J
Burden
R � 600 �
H
 Marker label
supply
�
20
10
IN [%]
10 20 30 40 50 60 70 80 90 100
Offset remote poti
SW1.6 = +22.5 %
SW1.4 = +100 %
2CDC 282 018 F0203
 Gain: Fine adjustment
G Pot.
2CDC 282 015 F0206
+ 2.5 V
SW1.5 = +50 %
5
DIP switch settings
Coarse
Type
C
C
5
1
8
3
0
6
2
8
3
0
3
3
D
0
6
4
2
5
B
3
4
1
4
3
D
5
-
Output
*) Detection of input voltage signal interruptions:
If the input signal circuit is interrupted, the output signal changes to the adjusted minimum value (low fail safe) or maximum value (high fail safe). If "No fail safe" is configured, input signal interruptions are not detected.
Type
CC-U/STD
2CDC110004C0205
Legend
ON
OFF
no influence
Rated supply voltage
Order code
Pack. unit
pieces
24-48 V DC
110-240 V AC
1SVR 040 000 R1700
1SVR 040 001 R0400
1
1
• Accessories . ............................................................................ 216
• Dimensional drawings .............................................................. 223
204
Switch 2
1 2 3 4 5 6
0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
0...8 V
0...4 V
-10...-2 V
-5...-1 V
1.25...6.25 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...0.5 mA
0...13.33 mA
0...666 µA
0...16 mA
0...800 µA
0...8 mA
0...400 µA
2.5...12.5 mA
125...625 µA
3.33...16.66 mA
166...833 µA
0.2...1 mA
2...10 mA
100...500 µA
2CDC 282 003 F0204
Gain
A...D
A...D
4...5
0...1
7...9
3...4
0
5...7
2
7...9
2...4
0
3...4
3...4
B...F
0
5...7
3...4
2
4...5
A...D
2...4
4...5
0...1
4...5
4...2
B...F
4...6
-
2CDC 282 020 F0203
Switch 1
1 2 3 4 5 6 7 8
2CDC 282 019 F0203
Input
Potentiometer
0...50 mV
0...100 mV
0...250 mV
0...500 mV
0...1 V
0...2.5 V
0...5 V
0...10 V
1...5 V
2... 10 V
-10...+10 V
0...125 mV
0...8 V
-22.5...+22.5 mV
-11...+11 V
2.5...7.5 V
3.33...9.99 V
10...0 V
100...0 mV
0...1 mA
0...20 mA
4...20 mA
10...50 mA
20...4 mA
20...0 mA
-0.45...+0.45 mA
-55...+55 mA
High fail safe *)
Low faile safe *)
No fail safe *)
Price
1 piece
• Technical data ...........................................................................219
ABB
Analog standard signal converter
CC-U/STDR with relay output
2CDC 281 003 F0t03
Ordering details
CC-U/STDR universal signal converter for standard signals, with 2 threshold relay
outputs and with 3-way electrical isolation
�
�
�
�
�
�
�
�
�
J Standard signal converter with 7 setting ranges
J 2 threshold relay outputs with one c/o contact each (threshold and respective hysteresis can be adjusted independently from each other)
J Open-circuit or closed-circuit principle configurable by means of a DIP switch
J 2 yellow LEDs for clear status indication of the output relays
J Plug-in connecting terminals for inputs, outputs and supply
Wiring instruction
Function diagrams
Value R1
Closed-circuit principle
R1 Threshold value
CC-U/STDR
Threshold
R1 Hysteresis
Hysteresis
Temperature
Value R2
 Threshold value for R1
supply
 Hysteresis for R1
 R2: yellow LED -
Relay 2 energized
 R1: yellow LED -
Relay 1 energized
 Marker label
11-14
R1 11-12
21-24
R2 21-22
Open-circuit principle
Input
R1 Threshold value
Switch 1
1 2 3 4 5 6
0...0 V
0...5 V
0...1 V
-10...+10 V
1...5 V
0...20 mA
4...20 mA
Output
Closed-circuit principle
Open-circuit principle
R1 Hysteresis
Temperature
R2 Hysteresis
Legend
ON
OFF
no influence
2CDC 282 046 F0203
 U: green LED -
supply voltage
R2 Threshold value
DIP switch settings
2CDC 282 003 F0204
 Hysteresis for R2
2CDC 282 005 F0204
 Threshold value for R2
2CDC 282 044 F0203
 Plug-in connecting terminals
2CDC 282 016 F0206
R2 Hysteresis
R2 Threshold value
11-14
R1 11-12
21-24
R2 21-22
Switching points
Switching points of the output relay depending on the input range,
configuration open-circuit principle
IN [%]
tu
al
va
l
ue
100
Ac
90
Threshold value R1
2-100 %
of input range
80
Hysteresis R1
5-50 % of
threshold
value R1
70
60
50
40
Threshold value R2
2-100 %
of input range
30
20
Hysteresis R2
5-50 % of
threshold
value R2
0
Type
CC-U/STDR
R1
11-14
11-12
R2
21-24
21-22
OUT
Rated supply voltage
Order code
Pack. unit
pieces
24-48 V DC
110-240 V AC
1SVR 040 010 R0000
1SVR 040 011 R2500
1
1
• Accessories . ............................................................................ 216
• Technical diagrams .................................................................. 223
ABB
2CDC 282 021 F0203
10
Price
1 piece
• Technical data ...........................................................................220
• Dimensional drawings ...............................................................223
205
2CDC110004C0205
5
Temperature signal converter for RTD sensors
CC-E/RTD
CC-E/RTD temperature signal converter for RTD sensors, linearized with 3-way electrical isolation
�
�
�
2 universally configurable devices (type CC-E/RTD)
2x12 single-function devices
"Plug and Work", no adjustment of single-function devices required
Temperature signal converter for PT100 sensors
2- or 3-wire connection
DIP switch settings (universal devices)
Wiring instruction
Input
0...100 °C
0...300 °C
G
H
Burden
R � 500 �
J
 Gain adjustment
 Offset adjustment
supply
24 V DC or 110-240 V AC
 U: green LED -
supply voltage
 DIP switch for input and output configuration (only available on universal
devices)
-50...+50 °C
-50...+250 °C
-50...+450 °C
Switch 1
1 2 3 4 5 6
0...10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
High fail safe
Low fail safe
Type
Output signal
Order code
Pack. unit
piece
refer to table
0-10 V, 0-20 mA, 4-20 mA
1SVR 011 701 R25001)
1
CC-E RTD/V
CC-E RTD/I
CC-E RTD/I
PT100 0...100 °C
0-10 V
0-20 mA
4-20 mA
1SVR 011 730 R2500
1SVR 011 731 R1200
1SVR 011 732 R1300
1
1
1
CC-E RTD/V
CC-E RTD/I
CC-E RTD/I
PT100 -50...+50 °C
0-10 V
0-20 mA
4-20 mA
1SVR 011 733 R1400
1SVR 011 734 R1500
1SVR 011 735 R1600
1
1
1
CC-E RTD/V
CC-E RTD/I
CC-E RTD/I
PT100 0...300 °C
0-10 V
0-20 mA
4-20 mA
1SVR 011 736 R1700
1SVR 011 737 R1000
1SVR 011 738 R2100
1
1
1
CC-E RTD/V
CC-E RTD/I
CC-E RTD/I
PT100 -50...+250 °C
0-10 V
0-20 mA
4-20 mA
1SVR 011 739 R2200
1SVR 011 740 R0700
1SVR 011 741 R2400
1
1
1
refer to table
0-10 V, 0-20 mA, 4-20 mA
1SVR 011 706 R2200
1
CC-E RTD/V
CC-E RTD/I
CC-E RTD/I
PT100 0...100 °C
0-10 V
0-20 mA
4-20 mA
1SVR 011 788 R2400
1SVR 011 789 R2500
1SVR 011 790 R2200
1
1
1
CC-E RTD/V
CC-E RTD/I
CC-E RTD/I
PT100 -50...+50 °C
0-10 V
0-20 mA
4-20 mA
1SVR 011 791 R1700
1SVR 011 792 R1000
1SVR 011 793 R1100
1
1
1
CC-E RTD/V
CC-E RTD/I
CC-E RTD/I
PT100 0...300 °C
0-10 V
0-20 mA
4-20 mA
1SVR 011 794 R1200
1SVR 011 795 R1300
1SVR 011 796 R1400
1
1
1
CC-E RTD/V
CC-E RTD/I
CC-E RTD/I
PT100 -50...+250 °C
0-10 V
0-20 mA
4-20 mA
1SVR 011 797 R1500
1SVR 011 798 R2600
1SVR 011 799 R2700
1
1
1
Input signal
Legend
ON
OFF
no influence
Price
1 piece
Supply voltage: 24 V DC
universal
CC-E/RTD
5
0...500 °C
2CDC 282 007 F0206
CC-E/RTD
Burden
R � 1.0 k�
Output
2CDC 282 003 F0204
�
J
J
J
J
J
2CDC 282 006 F0204
2CDC 281 004 F0t03
Ordering details
single-function
Supply voltage: 110-240 V AC
universal
CC-E/RTD
single-function
B 1604 Class I, Div.2 (universal device)
1)
206
2CDC110004C0205
• Technical data .......................................................................... 217
• Dimensional drawings ...............................................................223
ABB
Temperature signal converter for RTD sensors
CC-U/RTD
CC-U/RTD universal signal converter for PT10, PT100, PT1000 temperature sensors
(acc. to IEC 751 and JIS C 16041), linearized with 3-way electrical isolation
�
�
�
�
�
�
J Configurable output signal response on input signal interruption (low fail safe / high fail safe)
J Adjustment and operating elements on the front-side
J Short-circuit proof signal outputs
J Plug-in connecting terminals for inputs, outputs and supply
1)
Japanese standard
Wiring instruction
G
Burden
R � 4.7 k�
J
Burden
R � 600 �
H
supply
24 V DC or 110-240 V AC
2CDC 282 017 F0206
2CDC 281 005 F0t03
Ordering details
Characteristic curves
Resistance of PT10, PT100 and PT1000 sensors depending on the temperature
CC-U/RTD
PT1000
 Plug-in connecting terminals
 Gain: Fine adjustment
 Offset adjustment
 U: green LED -
supply voltage
Resistance [�]
 Gain: Coarse adjustment
PT100
 Marker label
2CDC 282 022 F0203
PT10
Temperature [°C]
*) Detection of input signal interruptions:
If the input signal circuit is interrupted, the output signal changes
to the adjusted minimum value (low fail safe) or maximum value
(high fail safe).
Type
CC-U/RTD
Rated supply voltage
Order code
Pack. unit
pieces
24-48 V DC
110-240 V AC
1SVR 040 002 R0500
1SVR 040 003 R0600
1
1
• Accessories . ............................................................................ 216
• Dimensional drawings .............................................................. 223
ABB
Legend
ON
OFF
no influence
2CDC 282 003 F0204
Gain
Coarse
F
E
D
C
B
A
9
8
F
E
B
A
9
8
3
2
1
0
8
3
2
1
0
0
-
2CDC 282 023 F0203
Switch 1
Switch 2
Input
Range
1 2 3 4 5 6 1 2 3 4 5 6
0...500 °C
0...550 °C
0...600 °C
0...650 °C
PT10
0...700 °C
0...750 °C
0...800 °C
0...850 °C
0...50 °C
0...60 °C
0...70 °C
0...80 °C
0...90 °C
PT100 0...100 °C
0...200 °C
0...300 °C
0...400 °C
0...500 °C
0...10 °C
0...20 °C
0...30 °C
PT1000 0...40 °C
0...50 °C
0...60 °C
Low fail safe *)
High fail safe *)
Type
Switch 3
1 2 3 4 5 6
0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
0...8 V
0...4 V
-10...-2 V
-5...-1 V
1.25...6.25 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...0.5 mA
0...13.33 mA
0...666 µA
0...16 mA
0...800 µA
0...8 mA
0...400 µA
2.5...12.5 mA
125...625 µA
3.33...16.66 mA
166...833 µA
0.2...1 mA
2...10 mA
100...500 µA
2CDC 282 024 F0203
Output
DIP switch settings
Price
1 piece
• Technical data ...........................................................................219
207
2CDC110004C0205
5
Temperature signal converter for RTD sensors
CC-U/RTDR with relay output
CC-U/RTDR universal signal converter for temperature and resistance signals, with 2 threshold relay outputs and 3-way electrical isolation
J Temperature signal converter for PT100 signals (5 ranges up to 800 °C) and variable resistances from
0-380 q
J 2 threshold relay outputs with one c/o contact each (threshold and respective hysteresis can be adjusted independently from each other)
J Open-circuit or closed-circuit principle configurable by means of a DIP switch
J 2 yellow LEDs for clear status indication of the output relays
J Plug-in connecting terminals for inputs, outputs and supply
Wiring instruction
Value R1
G
υ
Threshold
J
Value R2
K
 Threshold value for R2
M
supply
24 V DC or 110-240 V AC
 Hysteresis for R2
R1 Threshold value
R1 Hysteresis
Temperature
R2 Hysteresis
R2 Threshold value
11-14
R1 11-12
21-24
R2 21-22
DIP switch settings
Open-circuit principle
R1 Threshold value
 R2: yellow LED -
Relay 2 energized
R1 Hysteresis
Switch 1
1 2 3 4 5 6
Input PT100
0...100 °C
0...200 °C
0...400 °C
0...600 °C
0...800 °C
R2 Hysteresis
Output
Closed-circuit principle
Open-circuit principle
Legend
ON
OFF
no influence
2CDC 282 046 F0203
 Marker label
Temperature
2CDC 282 007 F0204
 R1: yellow LED -
Relay 1 energized
R2 Threshold value
11-14
R1 11-12
21-24
R2 21-22
Switching points
Switching points of the output relay depending on the input range,
configuration open-circuit principle
IN [%]
va
lu
e
100
800
Ac
tu
Threshold value R1
2-100 %
of input range
600
al
90
700
80
Hysteresis R1
5-50 % of
threshold
value R1
70
500
60
50
400
300
40
Threshold value R2
2-100 %
of input range
200
30
20
100
Hysteresis R2
5-50 % of
threshold
value R2
10
0
50
100
150
200
250
300
350
Resistance [�]
Type
CC-U/RTDR
R1
11-14
11-12
R2
21-24
21-22
Rated supply voltage
Order code
Pack. unit
pieces
24-48 V DC
110-240 V AC
1SVR 040 012 R2600
1SVR 040 013 R2700
1
1
• Accessories . ............................................................................ 216
• Technical diagrams .................................................................. 223
208
2CDC110004C0205
OUT
400
2CDC 282 025 F0203
Temperature υ [°C]
5
B (22)
C (21)
A (24)
R2
 Hysteresis for R1
Closed-circuit principle
Hysteresis
H
 Threshold value for R1
 U: green LED -
supply voltage
E (12)
F (11)
D (14)
R1
2CDC 282 044 F0203
CC-U/RTDR
 Plug-in connecting terminals
Function diagrams
2CDC 282 045 F0203
�
�
�
�
�
�
�
�
�
2CDC 282 003 F0204
2CDC 281 006 F0t03
Ordering details
Price
1 piece
• Technical data ...........................................................................220
• Dimensional drawings ...............................................................223
ABB
Temperature signal converter for thermocouples
CC-E/TC
2CDC 281 007 F0t03
Ordering details
CC-E/TC analog signal converter for thermocouple signals of the types J and K with 3-way electrical isolation
J 2 universally configurable devices (type CC-E/TC)
J 2x6 single-function devices
J "Plug and Work", no adjustment of single-function devices required
�
�
�
Wiring instruction
DIP switch settings (universal devices)
�
supply
24 V DC or 110-240 V AC
 Gain adjustment
TC-J:
0...600 °C
TC-K:
0...1000 °C
Output
Switch 1
1 2 3 4 5 6
0...10 V
0...20 mA
4...20 mA
0...10 V
0...20 mA
4...20 mA
High fail safe
Low fail safe
Legend
ON
OFF
no influence
2CDC 282 003 F0204
CC-E/TC
Input
2CDC 282 008 F0206
Burden
R � 500 �
2CDC 282 009 F0204
Burden
R � 1.0 k�
 Offset adjustment
 U: green LED -
supply voltage
 DIP switch for input and output configuration
(only available on universal
devices)
Type
Input signal
Output signal
Order code
Pack. unit
piece
0-10 V, 0-20 mA, 4-20 mA
1SVR 011 702 R26001)
1
Price
1 piece
Supply voltage: 24 V DC
universal
CC-E/TC
thermocouple types J and K
5
single-function
CC-E TC/V
CC-E TC/I
CC-E TC/I
type J 0...600 °C
0-10 V
0-20 mA
4-20 mA
1SVR 011 750 R0100
1SVR 011 751 R2600
1SVR 011 752 R2700
1
1
1
CC-E TC/V
CC-E TC/I
CC-E TC/I
type K 0...1000 °C
0-10 V
0-20 mA
4-20 mA
1SVR 011 753 R2000
1SVR 011 754 R2100
1SVR 011 755 R2200
1
1
1
0-10 V, 0-20 mA, 4-20 mA
1SVR 011 707 R2300
1
Supply voltage: 110-240 V AC
universal
CC-E/TC
thermocouple types J and K
single-function
B 1604 Class I, Div.2 (universal device)
CC-E TC/V
CC-E TC/I
CC-E TC/I
type J 0...600 °C
0-10 V
0-20 mA
4-20 mA
1SVR 011 760 R0300
1SVR 011 761 R2000
1SVR 011 762 R2100
1
1
1
CC-E TC/V
CC-E TC/I
CC-E TC/I
type K 0...1000 °C
0-10 V
0-20 mA
4-20 mA
1SVR 011 763 R2200
1SVR 011 764 R2300
1SVR 011 765 R2400
1
1
1
1) ABB
• Technical data .......................................................................... 217
• Dimensional drawings ...............................................................223
209
2CDC110004C0205
Temperature signal converter for thermocouples
CC-U/TC
Ordering details
�
�
�
�
�
�
J Temperature signal converter for thermo-
couples of the types K, J, T, S, E, N, R, B
J Continuously adjustable voltage signal input 0-10 mV and 0-50 mV
J Differential temperature meas. possible 1)
J Configurable output signal response on input signal interruption (low fail safe / high fail safe)
J Adjustment and operating elements on the front-side
J Short-circuit proof signal outputs
J Plug-in connecting terminals for inputs, outputs and supply
Wiring instruction
Burden
R � 4.7 k�
Burden
R � 600 �
supply
2CDC 282 018 F0206
2CDC 281 008 F0t03
CC-U/TC universal signal converter for thermocouples with 3-way electrical isolation
1)
 Plug-in connecting terminals
without cold-junction compensation:
DIP switch settings
switch SW2.2 = OFF
 Gain: Fine adjustment
Switch 1
Switch 2
Input
Range
1 2 3 4 5 6 1 2 3 4 5 6
0-100...900 °C
K 0-250...1350 °C
J
0-100...750 °C
0-100...400 °C
T -150-0...400 °C
S 0-250...1550 °C
0-100...700 °C
E 0-200...1000 °C
0-100...650 °C
N 0-200...1300 °C
0-250...1350 °C
R
0-450...1700 °C
B 0-700...1750 °C
0-2...10 mV
mV 0-10...50 mV
Low fail safe *)
High fail safe *)
Type
 Offset adjustment
*) Detection of input signal interruptions:
If the input signal circuit is interrupted, the output signal changes
to the adjusted minimum value (low fail safe) or maximum value
(high fail safe).
Characteristic curves
Thermocouple voltages depending on the temperature
80000
Typ E
75000
Typ J
70000
65000
60000
Typ K
55000
50000
Typ N
45000
40000
35000
30000
25000
Typ R
Typ T
20000
Typ S
15000
Legend
ON
OFF
no influence
2CDC 282 003 F0204
10000
Typ B
5000
0
-5000
-10000
1800
1750
1700
1650
1600
1550
1500
1450
1400
1350
1300
1250
1200
1150
1100
1050
1000
950
900
850
800
750
700
650
600
550
500
450
400
350
300
250
200
150
0
50
100
-50
-100
-150
-200
-250
-15000
Temperatur [°C]
Type
CC-U/TC
Rated supply voltage
Order code
Pack. unit
pieces
24-48 V DC
110-240 V AC
1SVR 040 004 R0700
1SVR 040 005 R0000
1
1
• Accessories . ............................................................................ 216
• Dimensional drawings .............................................................. 223
210
2CDC110004C0205
2CDC 282 026 F0103
5
0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
0...8 V
0...4 V
-10...-2 V
-5...-1 V
1.25...6.25 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...0.5 mA
0...13.33 mA
0...666 µA
0...16 mA
0...800 µA
0...8 mA
0...400 µA
2.5...12.5 mA
125...625 µA
3.33...16.66 mA
166...833 µA
0.2...1 mA
2...10 mA
100...500 µA
2CDC 282 020 F0203
 Marker label
Switch 2
1 2 3 4 5 6
Output
Thermoelement-Spannung [µV]
 U: green LED -
supply voltage
2CDC 282 010 F0204
 Gain: Coarse adjustment
2CDC 282 019 F0206
CC-U/TC
Price
1 piece
• Technical data ...........................................................................219
ABB
Temperature signal converter for thermocouples
CC-U/TCR with relay output
2CDC 281 009 F0t03
Ordering details
CC-U/TCR universal signal converter for thermocouples, with 2 threshold relay outputs and 3-way electrical isolation
�
�
�
�
�
�
�
�
�
J Temperature signal converter for thermocouples of the types K, J, T, S
J 2 threshold relay outputs with one change-over contact each (threshold and respective hysteresis can
be adjusted independently from each other)
J Open-circuit or closed-circuit principle configurable by means of a DIP switch
J 2 yellow LEDs for clear status indication of the output relays
J Plug-in connecting terminals for inputs, outputs and supply
Wiring instruction
Function diagrams
Value R1
Closed-circuit principle
R1 Threshold value
CC-U/TCR
R1 Hysteresis
Threshold
Hysteresis
Temperature
2CDC 282 044 F0203
R2 Hysteresis
2CDC 282 020 F0206
R2 Threshold value
 Plug-in connecting terminals
Value R2
 Threshold value for R1
 Hysteresis for R1
supply
11-14
R1 11-12
21-24
R2 21-22
 Threshold value for R2
 R1: yellow LED -
Relay 1 energized
 Marker label
Open-circuit principle
R1 Threshold value
R1 Hysteresis
Switch 1
Input
Type
Range
1 2 3 4 5 6
0...240 °C
J
0...480 °C
0...1200 °C
0...250 °C
0...500 °C
K
0...1350 °C
-150...+120 °C
0...220 °C
T
0...400 °C
0...210 °C
0...380 °C
S
0...860 °C
0...1550 °C
Output
Closed-circuit principle
Open-circuit principle
Temperature
R2 Hysteresis
2CDC 282 046 F0203
 R2: yellow LED -
Relay 2 energized
DIP switch settings
R2 Threshold value
11-14
R1 11-12
21-24
R2 21-22
2CDC 282 003 F0204
 U: green LED -
supply voltage
2CDC 282 004 F0204
 Hysteresis for R2
Legend
ON
OFF
no influence
Switching points
Switching points of the output relay depending on the input range,
configuration open-circuit principle
IN [%]
100
7000
Threshold value
R1 = 1000 °C
Typ J
6500
6000
Thermocouple voltage [µV]
5500
5000
Typ K
Release hysteresis
4500
4000
3500
Threshold value
R2 = 400 °C
3000
2500
Typ T
Release hysteresis
2000
1500
Typ S
1000
500
0
0
OUT
-1000
Temperature [°C]
Type
CC-U/TCR
R2
21-24
21-22
Rated supply voltage
Order code
Pack. unit
pieces
24-48 V DC
110-240 V AC
1SVR 040 014 R2000
1SVR 040 015 R2100
1
1
• Accessories . ............................................................................ 216
• Technical diagrams .................................................................. 223
ABB
R1
1825
1725
1625
1525
1425
1325
1225
1125
925
1025
825
725
625
525
425
325
225
25
125
-75
-175
-275
-1500
11-14
11-12
2CDC 282 027 F0203
-500
Price
1 piece
• Technical data ...........................................................................220
• Dimensional drawings ...............................................................223
211
2CDC110004C0205
5
Measuring converter for sinusoidal and DC
currents CC-E/I
2CDC 281 010 F0t03
Ordering details
CC-E/I current measuring converter for current signals 0-5 A, 0-20 A, AC/DC with 3-way electrical isolation
J 2 universally configurable devices (type CC-E/I)
J 2x6 single-function devices
J "Plug and Work", no adjustment of single-function devices required
�
�
Wiring instruction
�
�
Burden
R � 500 �
CC-E/I
supply
24 V DC or 110-240 V AC
2CDC 282 009 F0206
Burden
R � 1.0 k�
 Gain adjustment
Input range selection
DIP switch settings (universal devices)
Select input range by terminals
 DIP switch for input and output configuration
(only available on universal devices)
Connected lines
Used terminals
Terminal marking
Input range 20 A
Connected lines
Used terminals
Terminal marking
Input
I - DC
I - AC
I - DC
I - AC
I - DC
I - AC
Output
Switch 1
1 2 3 4 5 6
0...10 V
0...20 mA
4...20 mA
Legend
ON
OFF
2CDC 282 002 F0204
Input range 5 A
2CDC 282 008 F0204
 U: green LED -
supply voltage
2CDC 282 011 F0204
 Offset adjustment
5
Type
Input signal
Output signal
Order code
Pack. unit
pieces
Price
1 piece
Supply voltage: 24 V DC
universal
CC-E/I
0-5 A, 0-20 A, AC/DC
0-10 V, 0-20 mA, 1SVR 011 703 R27001)
4-20 mA
1
single-function
CC-E IAC/V
CC-E IAC/I 0-5 A, 0-20 A, AC
CC-E IAC/I
0-10 V
0-20 mA
4-20 mA
1SVR 011 770 R0500
1SVR 011 771 R2200
1SVR 011 772 R2300
1
1
1
CC-E IDC/V
CC-E IDC/I 0-5 A, 0-20 A, DC
CC-E IDC/I
0-10 V
0-20 mA
4-20 mA
1SVR 011 773 R2400
1SVR 011 774 R2500
1SVR 011 775 R2600
1
1
1
0-10 V, 0-20 mA, 4-20 mA
1SVR 011 708 R0400
1
CC-E IAC/V
CC-E IAC/I 0-5 A, 0-20 A, AC
CC-E IAC/I
0-10 V
0-20 mA
4-20 mA
1SVR 011 780 R1100
1SVR 011 781 R0600
1SVR 011 782 R0700
1
1
1
CC-E IDC/V
CC-E IDC/I 0-5 A, 0-20 A, DC
CC-E IDC/I
0-10 V
0-20 mA
4-20 mA
1SVR 011 783 R0000
1SVR 011 784 R0100
1SVR 011 785 R1100
1
1
1
Supply voltage: 110-240 V AC
universal
CC-E/I
0-5 A, 0-20 A, AC/DC
single-function
B 1604 Class I, Div.2 (universal device)
1)
212
2CDC110004C0205
• Technical data .......................................................................... 221
• Dimensional drawings ...............................................................223
ABB
Measuring converter for sinusoidal currents
CC-E IAC/ILPO
2CDC 281 018 F0t04
Ordering details
CC-E IAC/ILPO current measuring without auxiliary power for sinusoidal currents 0-1 A, 0-5 A, output 4 - 20 mA
�
J
J
J
J
Measuring converter for sinusoidal AC currents (0-1 A, 0-5 A)
Measuring range selection by front-face sliding switch
4-20 mA output current in propotion to input current
no additional power supply required
�
�
Wiring instruction
CC-E IAC/ILPO
 Gain adjustment
2CDC 282 010 F0b06
 Offset adjustment
 Selection of measuring
range
5
Type
CC-E IAC/ILPO
Input signal
Order code
Pack. unit
pieces
0-1 A, 0-5 A, AC
1SVR 010 203 R0500
1
• Technical data .......................................................................... 221
ABB
Price
1 piece
• Dimensional drawings ...............................................................223
213
2CDC110004C0205
Measuring converter for current RMS values
CC-U/I
2CDC 281 012 F0t03
Ordering details
CC-U/I universal current measuring converter for RMS values of 0-1 A and 0-5 A, with 3-way electrical isolation
�
�
�
J RMS converter for current signals up to 1 A and up to 5 A of any wave form (DC, DC with superimposed
AC components, pure sinusoidal, triangular, phase-angle controlled, etc. in a measuring range of 0-600 Hz)
J Adjustment and operating elements on the front
J Short-circuit proof signal outputs
J Plug-in connecting terminals for inputs, outputs and supply
�
DIP switch settings
Output
Burden
R � 600 �
 Plug-in connecting terminals
supply
24 V DC or 110-240 V AC
 Gain adjustment
2CDC 282 021 F0206
Burden
R � 4.7 k�
CC-U/I
 Offset adjustment
 U: green LED -
supply voltage
 Marker label
Input range selection
Select input range by terminals
Input range 1 A
5
J
5A
H
1A
G
C
Input range 5 A
Connected lines
Used terminals
Terminal marking
J
5A
H
1A
G
C
2CDC 282 033 F0203
Connected lines
Used terminals
Terminal marking
Switch 1
1 2 3 4 5 6
0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
0...8 V
0...4 V
-10...-2 V
-5...-1 V
1.25...6.25 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...0.5 mA
0...13.33 mA
0...666 µA
0...16 mA
0...800 µA
0...8 mA
0...400 µA
2.5...12.5 mA
125...625 µA
3.33...16.66 mA
166...833 µA
0.2...1 mA
2...10 mA
100...500 µA
Legend
ON
OFF
no influence
2CDC 282 003 F0204
Wiring instruction
2CDC 282 029 F0203
�
Example of application
RMS measurement and conversion of a current signal
IN [%]
Gain �15 %
I(t) [A]
5
4
3
2
1
resulting
RMS value
0
t
-1
0
50
OUT [%]
100
-2
2CDC 282 028 F0203
Offset �20 %
-3
-4
-5
Type
CC-U/I
Rated supply voltage
Order code
Pack. unit
pieces
24-48 V DC
110-240 V AC
1SVR 040 006 R0100
1SVR 040 007 R0200
1
1
• Accessories . ............................................................................ 216
• Dimensional drawings .............................................................. 223
214
2CDC110004C0205
Price
1 piece
• Technical data ...........................................................................222
ABB
Measuring converter for voltage RMS values
CC-U/V
2CDC 281 013 F0t03
Ordering details
CC-U/V universal voltage measuring converter for RMS values of 0-600 V, with 3-way electrical isolation
�
�
�
�
�
J RMS converter for voltage signals up to 600 V of any wave form (DC, DC with superimposed AC components, pure sinusoidal, triangular, phase-angle controlled, etc. in a measuring range of 0-600 Hz)
J Adjustment and operating elements on the front
J Short-circuit proof signal outputs
J Plug-in connecting terminals for inputs, outputs and supply
Wiring instruction
DIP switch settings
�
Burden
R � 600 �
 Input voltage range selection
supply
24 V DC or 110-240 V AC
 Gain adjustment
2CDC 282 022 F0206
Burden
R � 4.7 k�
 Offset adjustment
 U: green LED -
supply voltage
Input range selection
Selecting input range by
front-face rotary switch
0...100 V
0...150 V
0...250 V
0...300 V
0...400 V
0...450 V
0...550 V
0...600 V
Switch
position
1
2
3
4
5
6
7
8
2CDC 282 012 F0204
 Marker label
5
2CDC 282 029 F0203
CC-U/V
 Plug-in connecting terminals
Switch 1
1 2 3 4 5 6
0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
0...8 V
0...4 V
-10...-2 V
-5...-1 V
1.25...6.25 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...0.5 mA
0...13.33 mA
0...666 µA
0...16 mA
0...800 µA
0...8 mA
0...400 µA
2.5...12.5 mA
125...625 µA
3.33...16.66 mA
166...833 µA
0.2...1 mA
2...10 mA
100...500 µA
Legend
ON
OFF
no influence
2CDC 282 003 F0204
Output
Example of application
RMS measurement and conversion of a phase-angle controlled voltage signal L1 = 230 V
INUeff [V]
U(t) [V]
resulting
RMS value
Gain �15 %
OUT [%]
0
0
50
100
Offset �20 %
-300
operating angle
Type
CC-U/V
Rated supply voltage
Order code
Pack. unit
pieces
24-48 V DC
110-240 V AC
1SVR 040 008 R1300
1SVR 040 009 R1400
1
1
• Accessories . ............................................................................ 216
• Dimensional drawings .............................................................. 223
ABB
2CDC 282 030 F0203
300
Price
1 piece
• Technical data ...........................................................................222
215
2CDC110004C0205
Analog signal converters
Accessories for CC-U range
Ordering details
2CDC 252 187 F0005
62,5 2.46”
10
.394”
22,5
.886”
4,5
.177”
11,5
.453”
Accessories
Adapter for screw mounting
Type
ADP.01
60 2.36”
for type
Width
in mm
Order code
Pack. unit
pieces
CC-U
22.5
1SVR 430 029 R0100
1
for type
Order code
Pack. unit
pieces
CC-U
1SVR 366 017 R0100
1
Price
1 piece
Weight
1 piece
kg / lb
Price
1 piece
Weight
1 piece
kg / lb
Price
1 piece
Weight
1 piece
kg / lb
20
.787”
MAR.01
Marker label
2CDC 252 186 F0005
3A11
8
.315”
ADP.01
Type
7 .275”
3,5 .138”
68,5 2.70 ”
22,5
.886”
5
2CDC 252 185 F0005
MAR.01
Sealable transparent cover
Type
COV.01
for type
Width
in mm
Order code
Pack. unit
pieces
CC-U
22.5
1SVR 430 005 R0100
1
front-to-back
size 107
Sealable cover
COV.01
216
2CDC110004C0205
ABB
Analog signal converters
CC-E/STD, CC-E x/x, CC-E/RTD, CC-E/TC
Technical data
Type
Input circuits - Analog inputs
CC-E/STD
J-G-H
Input signal
Rated input range
Current
Voltage
1 M
50 
-
Output circuits - Analog outputs
Output signal
Output burden
Accuracy 1)
Residual ripple
Response time
Transmission frequency
Reaction to input circuit interruption
D-F, A-C Supply circuits
Supply voltage
Supply voltage tolerance
Power consumption
K-M -50...+500 °C
< 0.01 %/
± 5 % (universal devices)
± 5 % (universal devices)
100 dB
TC.K: 0...1000 °C, TC.J: 0...600 °C
< 0.5 % / 100 
> 35 dB
DC versions
24 V DC
-15...+15 %
1.5 W typ.
AC versions
110-240 V AC - 50/60 Hz
-15...+10 %
1.5 VA typ.
5
U: green LED
General data
Ambient temperature range
operation
storage
0...+60 °C
-20...+80 °C
± 500 ppm/°C
IP20
ventilation slots on top and bottom
DIN rail, snap-on mounting
rigid
fine-strand
4 mm2 (10 AWG)
2.5 mm2 (14 AWG)
Temperature coefficient
Degree of protection (DIN 40050)
Mounting position
Mounting
Electrical connection
Wire size
EN 61000-6-2
Level 3 (±6 kV / ±8 kV)
IEC/EN 61000-4-2
10 V/m
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
EN 61000-6-4
Isolation data
Test voltage between all isolated circuits
Rated insulation voltage
2)
PT100
CC-E/TC
Thermocouples
(IEC 584-1 and 2)
TC.K, TC.J
Current Voltage
0-20 mA, 4-20 mA 0-5 V, 0-10 V
m 500 
 1.0 K
± 0.5 % of full-scale
< 0.5 %
200 µs
10 ms
2 kHz
80 Hz
2 Hz (up to -3 dB)
Low fail safe: Output voltage > 15 % of measuring range 2)
Low fail safe: Output voltage < -0.6 V, output current = 0 mA
Indication of operational states
Rated control supply voltage US
1)
Temperature sensors
Standard signals
0...5 V /
0...20 mA /
0...10 V /
4...20 mA
-10...+10 V
+55 mA
± 11 V
-
Limitation of input signals
Influence of line resistance
Gain adjustment range
Offset adjustment range
Input impedance
Suppression at 50 Hz
Common-mode rejection
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
electromagnetic field
(HF radiation resistance)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
Interference emission
CC-E/RTD
Level 3 (±2 kV / 5 kH)
±2 kV / ±1 kV
10 V
class B
-
2.5 kV AC
-
-
includes: non-linearity, factory setting, drift of temperature, supply voltage and output load
Only -/RTD and -/TC: Single-function devices respond with Low fail safe to input signal interruptions
ABB
217
2CDC110004C0205
Analogsignal converter
CC-E I/I-1, CC-E I/I-2
Technical data
Type
Input circuits -
Analog inputs
Input current IIN
Min. input current
Max. input current
Input voltage UIN
Input voltage drop Ui
Max. input voltage
CC-E I/I
channel 1: A (+), B (-),
channel 1 or 2: C (+), D (-)
Output circuits
Output current IOUT
Output load RL
Output voltage UOUT
Residual ripple
Response time (0-100 %)
channel 1: H (+), G (-),
channel 2: F (+), E (-)
0-20 mA, 4-20 mA
0-500 
IOUT x RL
< 20 mVpp (500 , 20 mA)
< 15 ms (0-500 , 20 mA),
< 5 ms (500 , 20 mA, 25 °C)
 0.1 % of full-scale (20 mA)
 0.05 % / 100 ,
 -0.1 % / 100  (25 °C)
Accuracy
Load influence (0-500 )
General data
Width of the enclosure
Weight
5
Current
0-20 mA, 4-20 mA
< 100 µA
50 mA1) (VIN < 18 V)
< 2.5 V + (IIN x RL)
< 2.5 V (20 mA, RL = 0 )
18 V1) (IIN < 50 mA)
Temperature coefficient
Mounting
18 mm
approx. 0.037 kg (0.082 lb)
approx. 0.044 kg (0.097 lb)
any
IP20 / IP20
-25...+60 °C
-40...+85 °C
< 50 ppm / °C
DIN rail (EN 50022)
Electrical connection
Wire size
max. 2.5 mm2 (14 AWG)
Standards
Product standard
Low Voltage Directive
EMC Directive
EN 50178
2006/95/EC
2004/108/EC
Mounting position
Degree of protection
Ambient temperature range
1 channel
2 channel
enclosure / terminals
operation
storage
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
electromagnetic field
(HF radiation resistance)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
magnetisches Feld
Interference emission
Radiated noise
Operational reliability (EN 68-2-6)
Mechanical resistance (EN 68-2-6)
Environmental testing (IEC 68-2-30 Db)
Isolation data
Insulation voltage input / output
Insulation voltage between
channels
Pollution category
Overvoltage category
1)
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 55011
EN 61000-6-2
Level 3 (±6 kV / ±8 kV)
10 V/m
Level 3 (±2 kV / 5 kH)
±2 kV / ±1 kV
10 V
30 A/m
EN 61000-6-4
class B
4g
10 g
24 h cycle, 55 °C, 93 % rel., 96 h
500 Veff / 50 Hz
(device with 2 channels)
5 kVeff / 50 Hz
2
II
The input parameters have to be limited to the indicated maximum values.
218
2CDC110004C0205
ABB
Analog signal converters
CC-U/STD, CC-U/RTD, CC-U/TC
Technical data
Type
Input circuits - Analog inputs
CC-U/STD
J-G-H
Input signal
Current
0-20 mA
4-20 mA
10-50 mA
0-1 mA
Limitation of input signals
Rated input range
± 55 mA
-
Influence of line resistance
Gain adjustment range
(universal devices)
Offset adjustment range (universal devices)
Input impedance
without detection of input signal interruption
with detection of input signal interruption
Suppression at 50 Hz
Common-mode rejection
Output circuits - Analog outputs
Output signal
Output burden
Accuracy 1)
Residual ripple
Response time
Transmission frequency
Supply circuits
Rated supply voltage
Supply voltage range
Supply voltage tolerance
Rated frequency
Power consumption
D-F, A-C
CC-U/RTD
PotentioVoltage
meter
0-100 mV 470  0-1 V
1 M 2)
0-5 V
1-5 V
0-10 V
2-10 V
± 10 V
± 11 V
-
-
0.945 mV 110 mA
22 V
-137.5...+62.5 %
for different ranges
51 
6 M
3 G
51 
3.5 M
9.5 G
< 0.01 % / 100 
±5%
120 dB
± 10 %
> 40 dB
105 dB
5
24-48 V DC
110-240 V AC
24-48 V DC / 24 V AC
110-240 V AC / 100-300 V DC
DC: -15...+15 %
AC: -15...+10 %
0 Hz or 50/60 Hz
2 W at 24 V DC
4.5 VA at 230 V AC
operation
storage
-20...+60 °C
-40...+80 °C
±150 ppm/°C
±250 ppm/°C
±200 ppm/°C at min. offset
±400 ppm/°C at max. offset
any
DIN rail, snap-on mounting / screw mounting with adapter
rigid
fine-strand
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
EN 61000-6-4
plug-connector with screw terminals 1.5 mm2 (16 AWG)
plug-connector with screw terminals 2.5 mm2 (14 AWG)
EN 61000-6-2
Level 3 (±6 kV / ±8 kV)
10 V/m
Level 3 (±2 kV / 5 kH)
2 kV / 1 kV
10 V
Class B
1.5 kV
Test voltage (between all isolated circuits)
1.5 kV / 50 Hz
2)
refer to temperature specs.
of individual thermocouples
see DIP switch settings
Isolation data
Isolation test (between all isolated circuits)
1)
-
U: green LED
Mounting position
Mounting
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
electromagnetic field
(HF radiation resistance)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
Interference emission
Max. temperature adjustable:
6-60 °C for PT1000
50-500 °C for PT100
500-850 °C for PT10
0.015 °C/
K-M
Temperature coefficient
Electrical connection
Wire size
PT10, PT100, PT1000
(IEL 751 and JICC 1604)
Current Voltage
0-20 mA, 4-20 mA
0-5 V, 1-5 V, 0-10 V, 2-10 V, ± 10 V
 600 
 4.7 K
±0.1 % of full-scale
±0.2 % of full-scale
±0.1 % of full-scale
< 0.15 %
200 µs
10 ms
200 ms
1 kHz
80 Hz
2 Hz (to -3 dB)
Indication of operational states
Supply voltage
General data
Ambient temperature range
Temperature sensors
CC-U/TC
Thermocouples
(IEC 584-1 and 2)
TC.K
TC.J
TC.T
TC.S
TC.E
TC.N
TC.R
TC.B
includes: non-linearity, factory setting, drift of temperature, supply voltage and output load
Detection of an input signal break (fail safe) and resistance > 10 kq results in a linearity of w0,2 %.
ABB
219
2CDC110004C0205
Analog signal converters with relay output
CC-U/STDR, CC-U/RTDR, CC-U/TCR
Technical data
Type
Input circuits - Analog inputs
CC-U/STDR
J-H
Measuring signal / input range
Minimum switching voltage
Minimum switching current /
Response time
Mechanical lifetime
Electrical lifetime
5
E-D-F, B-C-A
at AC12, 230 V, 4 A
operation
storage
-20...+60 °C
-40...+80 °C
±300 ppm/°C
any
DIN rail (EN 50 022), snap-on mounting / screw mounting with adapter
rigid
fine-strand
plug-connector with screw terminals 1.5 mm2 (16 AWG)
plug-connector with screw terminals 2.5 mm2 (14 AWG)
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
EN 61000-6-4
Isolation data
Insulation voltage (between all isolated circuits)
Test voltage (between all isolated circuits)
220
2CDC110004C0205
24-48 V DC
110-240 V AC
24-48 V DC / 24 V AC
110-240 V AC / 100-300 V DC
DC: -15...+15 %
AC: -15...+10 %
0 Hz or 50/60 Hz
2 W at 24 V DC
4.5 VA at 230 V AC
U: green LED
R1: yellow LED / R2: yellow LED
Temperature coefficient
Mounting position
Mounting
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
electromagnetic field
(HF radiation resistance)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
Interference emission
(IEC 584-1 and 2)
TC.K, TC.J
TC.T, TC.S
K-M
Indication of operational states
Supply voltage
1st / 2nd output relay energized
Electrical connection
Wire size
Temperature sensors
CC-U/TCR
Thermocouples
Relay, 2 c/o contacts
250 V AC
4A
3A
4A
2A
12 V
10 mA / 0.6 VA (W)
10 ms
30 x 106 switching cycles
0.1 Mio. switching cycles
AC12 (resistive) 230 V
AC15 (inductive) 230 V
DC12 (resistive)
24 V
DC13 (inductive) 24 V
Supply circuits
Rated supply voltage
Supply voltage range
Supply voltage tolerance
Rated frequency
Power consumption
General data
Ambient temperature range
Voltage
0-20 mA
0-1 V / 1-5 V
PT100
4-20 mA
0-10 / ±10 V
approx. 50  approx. 1,5 M
2-100 % of selected input range
5-50 % of threshold
±0.5 % of full-scale
Input resistance
Adjustable threshold
Adjustable hysteresis
Repeat accuracy (constant parameters)
Output circuits - Relay outputs
Rated switching voltage
Rated switching current
Current
CC-U/RTDR
EN 61000-6-2
Level 3 (±6 kV / ±8 kV)
10 V/m
Level 3 (±2 kV / 5 kH)
2 kV / 1 kV
10 V
Class B
2.5 kV
2.5 kV
ABB
Analog signal converters
CC-E/I, CC-E IAC/ILPO
Technical data
Type
CC-E/I
J-G-H
Input circuits - Analog inputs
Rated input range
Measuring frequency
Overload capacity of inputs
input range 1
input range 2
Gain adjustment range
Offset adjustment range
Input impedance / resistance
Output circuits - Analog outputs
Accuracy 1)
Offset adjustment range
Gain adjustment range
Residual ripple
Response time
Transmission frequency
Reaction to input circuit interruption
Supply circuits
Supply voltage
Supply voltage tolerance
Power consumption
K-M
Indication of operational states
Supply voltage
General data
Ambient temperature range
operation
storage
Temperature coefficient
Degree of protection (DIN 40050)
Mounting position
Mounting
DC current
2 meas. ranges selectable
0-5 A / 0-20 A
0-1 A / 0-5 A / sinusoidal
50/60 Hz
10 x INom (50 A) for max. 2 s
10 x INom (200 A) for max. 2 s
5 m
10 x INom (50 A) for max. 1 s
10 x INom (200 A) for max. 1 s
±5 % (universal devices)
±5 % (universal devices)
20 A : 2.5 m
5A : 65 m
D-F
Current
A-C
Voltage
DC versions
24 V DC
-15...+15 %
typ 1.5 W
AC versions
110-240 V AC 50/60 Hz
-15...+10 %
typ 1.5 VA
5
12-30 V DC
-
U: green LED
-
0...+60 °C
-20...+80 °C
± 500 ppm/°C
-20...+60 °C
-40...+80 °C
300 ppm/°C
IP20
ventilation slots on top and bottom
DIN rail, snap-on mounting
Electrical connection
Wire size
rigid
fine-strand
4 mm2 (12 AWG)
2.5 mm2 (14 AWG)
1x2.5 mm2 (1x14 AWG)
EN 61000-6-2
Level 3 (±6 kV / ±8 kV)
IEC/EN 61000-4-2
10 V/m
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
EN 61000-6-4
Isolation data
Test voltage (between all isolated circuits)
Rated insulation voltage
1)
AC current
0-5 A / 0-20 A
F-E
passive current output in proportion
to input current
0-20 mA / 4-20 mA
0-10 V
4-20 mA
12 V DC: 150 ,  500 
 1.0 
24 V DC: 750 
30 V DC: 1050 
± 2 % of full-scale
±5 % (universal device)
±5%
±5 % (universal device)
± 20 %
< 0.5 %
0.5 s
0.6 s
DC or 50/60 Hz
AC: 50/60 Hz
Low fail safe: output voltage < 200 mA,
output current < 400 µA
Output signal
Output burden / load
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
electromagnetic field
(HF radiation resistance)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
Interference emission
CC-E IAC/ILPO
C-D
Level 3 (±2 kV / 5 kH)
±2 kV / ±1 kV
10 V
Class B
2.5 kV AC
-
250 V AC
includes: non-linearity, factory setting, drift of temperature, supply voltage and output load
ABB
221
2CDC110004C0205
Analog signal converters
CC-U/I, CC-U/V
Technical data
Type
Input circuits - Analog inputs
J-G-H
Rated input range
Measuring frequency
Overload capacity of inputs
0-600 Hz
input range 1
input range 2
10 x INom (10 A) for max. 2 s
10 x INom (50 A) for max. 2 s
D-F, A-C
Current
0-20 mA, 4-20 mA
 600 
Voltage
0-5 V, 1-5 V, 0-10 V, 2-10 V, ± 10 V
 4.7 K
±0.5 % of full-scale
±250 ppm/°C max.
±300 ppm/°C max.
< 0.15 %
150 ms
K-M
24-48 V DC
24-48 V DC, 24 V AC
DC: -15...+15 %
2 W at 24 V DC
110-240 V AC
110-240 V AC, 100-300 V DC
AC: -15...+10 %
0 Hz or 50/60 Hz
4.5 VA at 230 V AC
U: green LED
operation
storage
-20...+60 °C
-40...+80 °C
any
DIN rail (EN 50022), snap-on mounting / screw mounting with adapter
rigid
fine-strand plug-connector with screw terminals 1.5 mm2 (16 AWG)
plug-connector with screw terminals 2.5 mm2 (14 AWG)
Mounting position
Mounting
Electrical connection
Wire size
±15 %
±20 %
> 800 k
Indication of operational states
Supply voltage
General data
Ambient temperature range
-
1A: 60 m,
5 A: 12 m
Supply circuits
Rated supply voltage
Supply voltage range
Supply voltage tolerance
Rated frequency
Power consumption
5
CC-U/V
any voltage signals,
RMS measurement
0-100 V, 0-200 V
0-300 V, 0-400 V
0-500 V, 0-600 V
0-1 A
0-5 A
Gain adjustment range
Offset adjustment range
Input impedance / resistance
Output circuits - Analog outputs
Output signal
Output load
Accuracy1)
Temperature coefficient
Residual ripple
Response time
CC-U/I
any current signals,
RMS measurement
Standards
Product standard
Low Voltage Directive
EMC Directive
RoHS Directive
Electromagnetic compatibility
Interference immunity
electrostatic discharge (ESD)
electromagnetic field
(HF radiation resistance)
fast transients (Burst)
powerful impulses (Surge)
HF line emission
Interference emission
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
EN 61000-6-4
EN 61000-6-2
Level 3 (±6 kV / ±8 kV)
10 V/m
Level 3 (±2 kV / 5 kH)
2 kV / 1 kV
10 V
Class B
Isolation data
Insulation voltage (between all isolated circuits)
Test voltage (between all isolated circuits)
1)
1.5 kV
1.5 kV / 50 Hz
includes: non-linearity, factory setting, drift of temperature, supply voltage and output load
222
2CDC110004C0205
ABB
Analog signal converters
CC-E, CC-U
Technical diagr., Connection diagr., Dimensional drawings
Technical diagrams
Connection diagram CC-U/x
Width 22.5 mm (0.89 in)
Load limit curves CC-U/xxR
Resistive DC load
L
K
J
H
G
1.0
0.9
D
E
F
A
B
C
0.8
2CDC 282 023 F0b06
Derating curve
M
2CDC 282 026 F0b06
2CDC 282 025 F0b06
Resistive AC load
F
0.7
0.5
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
cos
1.0
2CDC 282 014 F0b06
0.6
5
Dimensional drawnings
Dimensions in mm
2CDC282011F0b06
22.5
0,88 "
18
0.71"
2CDC282012F0b06
CC-E IAC/ILPO, CC-E I/I
CC-E/x
.039
ABB
2CDC282024F0b06
CC-U/x , CC-U/xR
223
2CDC110004C0205
Notes
5
224
2CDC110004C0205