MODEL - 1005/1005A DIAL TYPE THERMOMETER STANDARD OTI / WTI General Features • The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and does not require any trimming or other periodic adjustments. • Instruments are fully compensated for ambient temperature. • The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A). • Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings and are provided with projection mounting clamps. • A maximum pointer facility is provided, can be reset from outside. • All switch contacts are potential free micro switches 1005/1005A Specifications Temperature Range Model : 1005 0 -1500C, 0 -1600C, 30 -1500C, -20 to 1400C 150mm (6”) Round 2700 10C ±1% of FSD 5 15% - 85% Model : 1005A 0 -1500C, 0 -1600C, 30 -1500C, -20 to 1400C 150mm (6”) Round 2700 10C ±1% of FSD 5 15% - 85% 3A @ 250V AC/DC Magnetic Blowout Micro switch 15A @ 250V AC 0.5A @ 250V DC Standard Micro switch S1 & S2: 3°C to 9°C (6±30C)Fixed S3 to S5: 8°C to 400C Adjustable. ±2.5 0C of Set Value Available (Potentiometer Output) Up to 25 Mtrs Available Press Fit Wago Type IP – 55(IEC - 60529) 2.5 KV AC, 50Hz/60Hz for 1 minute; all Terminals to ground S1 & S2: 3°C to 90C (6±30C)Fixed S3 to S5: 80C to 400C Adjustable. ±2.50C of Set Value Available (Potentiometer Output) Up to 25 Mtrs Available Press Fit Wago Type IP – 55(IEC - 60529) 2.5 KV AC, 50Hz/60Hz for 1 minute; all Terminals to ground Electrical entry M20 - 3Nos M20 - 3Nos Cable Gland Optional Optional Thermometer Pocket Optional Optional Dial Size Dial angular Sweep Dial Graduation Accuracy Class Max. No. of Switches Switching Range Contact Rating Switch Differential Switching Accuracy Remote Repeater Max. Capillary Length Switch Test Knob Electrical Connection Degree of Protection High Voltage Test Remote Repeater 96 Sq Specifications Type 4 digits, 0.5’’ Seven Segments LED’s Auxillary Supply 90 – 260V AC/DC Resolution 0.10C Degree of protection of enclosure IP 20 Operating Temperature Range 00C to 600C Signal output 4 sets of 4 - 20mA DC Optional RS 485 Cutout dimension 92 Sq. mm www.precimeasure.com DIAL TYPE Precimeasure Type Tested For 1. Protection class : IP55 as per IEC 60529 CAT 2. 2. Cold and Dry Test : -40°C to +70°C 3. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis 4. Salt Spray Test : For polyester powder coating and SS 304 Armour for 500 Hrs as per DIN 50021 Standard 5. Micro Switch rating Test : a) ML - 1005: 3A @ 250V AC & 3A @ 250V DC b) ML - 1005A: 15A @250V AC & 0.5A @250V DC Ordering Information Model Type of Instrument Range No. of Switches Switch Configuration Capillary Length Union Type Repeater If WTI please specify 1005 /1005A OTI / WTI R1. 0 - 150°C R2. 0 - 160°C R3. 30 - 150°C R4. -20 to140°C (other ranges on request) S2 - 2switches S3 - 3switches S4 - 4switches S5 - 5switches L - Normally open contact L2 - Changeover contact C1 - 1mts C2 - 2mts....... upto C25 - 25mts U1 - 1/2“ BSP Male U2 - 3/4” BSP Male U3 - 1”BSP Male U4 - 1/2” BSP Female U5 - 3/4” BSP Female Y - Requried N - Not Required Transformer CT Secondary output..................(1A to 5A) Simulated Temperature rise over top oil........... (5°C to 30°C) Note: WTI Gradient is factory set. If required customer can adjust as per requirement. Sample Ordering Information :1005\WTI\R3\S2\L2\C2\U1\Y\........... Amps ...............°C Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com MODEL - 1005H/1005AH DIAL TYPE THERMOMETER Hybrid OTI / WTI General Features • The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and does not require any trimming or other periodic adjustments. • Instruments are fully compensated for ambient temperature. • The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A). • Embedded PT-100 sensors in the sensing bulb of the local OTI/ WTI provide for a master indication. • Current Converter Unit (CCU) is mounted inside the Local OTI/WTI, The output from which can be connected to remote indicator or SCADA are a combination of both. • For the WTIs additional Winding temperature simulator is provided • Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings and are provided with projection mounting clamps. • A maximum pointer facility is provided, can be reset from outside. • All switch contacts are potential free micro switches ML : 1005H/1005AH Specifications Temperature Range Model : 1005H 0-1500C, 0-1600C, 30-1500C, -20 to 1400C 150mm (6”) Round 2700 10C ±1% of FSD 5 15% - 85% Model : 1005AH 0-1500C, 0-1600C, 30-1500C, -20 to1400C 150mm (6”) Round 2700 10C ±1% of FSD 5 15% - 85% 3A @ 250V AC/DC Magnetic Blowout Micro switch 15A @ 250V AC 0.5A @ 250V DC Standard Micro switch Electrical entry S1 & S2: 3°C to 9°C (6±30C) Fixed S3 to S5: 8°C to 400C Adjustable. ±2.5 0C of Set Value Available / 4 - 20mA / RS - 485 Up to 25 Mtrs. Available Press Fit Wago Type IP – 55(IEC-60529) 2.5 KV AC, 50Hz/60Hz for 1 minute; Switch connection & C.T. Terminal to ground. CCU output 0.5 Kv Ac 50Hz / 60Hz for 1 minute M20 - 3Nos S1 & S2: 3°C to 90C (6±30C)Fixed S3 to S5: 80C to 400C Adjustable. ±2.50C of Set Value Available / 4-20mA / RS - 485 Up to 25 Mtrs. Available Press Fit Wago Type IP – 55(IEC-60529) 2.5 KV AC, 50Hz/60Hz for 1 minute; Switch connection & C.T. Terminal to ground. CCU output 0.5 Kv Ac 50Hz / 60Hz for 1 minute M20 - 3Nos Cable Gland Optional Optional Thermometer Pocket Optional Optional Dial Size Dial angular Sweep Dial Graduation Accuracy Class Max.No. of Switches Switching Range Contact Rating Switch Differential Switching Accuracy Remote indicator Max. Capillary Length Switch Test Knob Electrical Connection Degree of Protection High Voltage Test Remote indicator 96 Sq SPECIFICATIONs Type 4 digits, 0.5’’ Seven Segments LED’s Auxillary Supply 90 – 260V AC/DC Resolution 0.10C Degree of protection of enclosure IP 20 Operating Temperature Range 00C to 600C Signal output 4 sets of 4 - 20mA DC Optional RS 485 Cutout dimension 92 Sq.mm www.precimeasure.com DIAL TYPE Precimeasure Type Tested For 1. Protection class : IP55 as per IEC 60529 CAT 2. 2. Cold and Dry Test : -40°C to +70°C 3. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis 4. Salt Spray Test : For polyster powder coating and SS 304 Armour for 500 Hrs as per DIN 50021 Standard 5. Micro Switch rating Test : a) ML - 1005H: 3A @ 250V AC & 3A @ 250V DC b) ML - 1005AH: 15A @250V AC & 0.5A @250V DC Ordering Information Model Type of Instrument Range No. of Switches Switch Configuration Capillary Length Union Type CCU Output for indication / Scada If WTI please specify 1005H/1005AH OTI / WTI R1. 0 - 150°C R2. 0 - 160°C R3. 30 - 150°C R4. -20 to140°C (other ranges on request) S2 - 2switches S3 - 3switches S4 - 4switches S5 - 5switches L - Normally open contact L2 - Changeover contact C1 - 1mts C2 - 2mts....... upto C25 - 25mts U1 - 1/2“ BSP Male U2 - 3/4” BSP Male U3 - 1”BSP Male U4 - 1/2” BSP Female U5 - 3/4” BSP Female RI - Remote indicator - T1/T2/T3/T4 (for types, Refer Drawing) PSU - External power supply with 2 Nos. of 4-20mA output Transformer CT Secondary output..................(1A to 5A) Simulated Temperature rise over top oil........... (5°C to 30°C) Note: WTI Gradient is factory set. If required customer can adjust as per requirment. Sample Ordering Information :1005AH\OTI\R4\S4\L\C6\U4\RI-T2 ........... Amps ...............°C Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com MODEL - 1005HX / 1005AHX DIAL TYPE THERMOMETER Duplex Hybrid OTI / WTI General Features • The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and does not require any trimming or other periodic adjustments. • Instruments are fully compensated for ambient temperature. • The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A). • Embedded Duplex PT-100 sensors in the sensing bulb of the local OTI/ WTI provide for a master indication. • Current Converter Units (CCUs) are mounted inside the Local OTI/WTI, The output from which can be connected to remote indicator and SCADA through external power supply units (PSUs). • For the WTIs additional Winding temperature simulator is provided • Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings and are provided with projection mounting clamps. • A maximum pointer facility is provided, can be reset from outside. • All switch contacts are potential free micro switches ML: 1005 HX/1005 AHX Specifications Temperature Range Model : 1005HX 0-1500C, 0-1600C, 30-1500C, -20 to 1400C 150mm (6”) Round 2700 10C ±1% of FSD 5 15% - 85% Model : 1005AHX 0-1500C, 0-1600C, 30-1500C, -20 to1400C 150mm (6”) Round 2700 10C ±1% of FSD 5 15% - 85% 3A @ 250V AC/DC Magnetic Blowout Micro switch 15A @ 250V AC 0.5A @ 250V DC Standard Micro switch Electrical entry S1 & S2: 3°C to 9°C (6±30C) Fixed S3 to S5: 8°C to 400C Adjustable. ±2.5 0C of Set Value Available / 4-20mA / RS - 485 Up to 25 Mtrs. Available Press Fit Wago Type IP – 55(IEC-60529) 2.5 KV AC, 50Hz/60Hz for 1 minute; Switch connection & C.T. Terminal to ground. CCU output 0.5 Kv Ac 50Hz / 60Hz for 1 minute M20 - 3Nos S1 & S2: 3°C to 90C (6±30C)Fixed S3 to S5: 80C to 400C Adjustable. ±2.50C of Set Value Available / 4-20mA / RS - 485 Up to 25 Mtrs. Available Press Fit Wago Type IP – 55(IEC-60529) 2.5 KV AC, 50Hz/60Hz for 1 minute; Switch connection & C.T. Terminal to ground. CCU output 0.5 Kv Ac 50Hz / 60Hz for 1 minute M20 - 3Nos Cable Gland Optional Optional Thermometer pocket Optional Optional Dial Size Dial angular Sweep Dial Graduation Accuracy Class Max.No. of Switches Switching Range Contact Rating Switch Differential PSU Switching Accuracy Remote indicator Max. Capillary Length Switch Test Knob Electrical Connection Degree of Protection High Voltage Test Remote Indicator 96 Sq Power Supply Unit - (PSU) a. Output Voltage: 24V b. Output Signal: Analogue output 2nos. 4-20mA DC (Output - 1, Burden 250 Ohms) (Output- 2, Burden 600 Ohms) c. Auxiliary supply: 90-260V AC/DC REMOTE INDICATOR a b d e f g h Type : 4 digits, 0.5’’ Seven Segment LED’s Auxiliary Supply : 90 – 260V AC/DC Resolution : 0.10C Degree of protection of enclosure : IP-20 Operating Temperature Range : 0°C to 60°C Signal output: 4sets of 4-20mA DC, Optional RS 485 Cutout Dimension: 92Sq.mm www.precimeasure.com DIAL TYPE Precimeasure Type Tested For Ordering Information 1. Protection class : IP55 as per IEC 60529 CAT 2. 2. Cold and Dry Test : -40°C to +70°C Model Type of Instrument Range 3. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis 4. Salt Spray Test : For polyster powder coating and SS 304 Armour for 500 Hrs as per DIN 50021 Standard 5. Micro Switchrating Test : a) ML - 1005HX: 3A @ 250V AC & 3A @ 250V DC b) ML - 1005AHX: 15A @250V AC & 0.5A @250V DC 1005HX/1005AHX OTI / WTI R1. 0 - 150°C R2. 0 - 160°C R3. 30 - 150°C R4. -20 to140°C (other ranges on request) No. of Switches S2 - 2switches S3 - 3switches S4 - 4switches S5 - 5switches Switch Configuration L - Normally open contact L2 - Changeover contact Capillary Length C1 - 1mts C2 - 2mts....... upto C25 - 25mts Union Type U1 - 1/2“ BSP Male U2 - 3/4” BSP Male U3 - 1”BSP Male U4 - 1/2” BSP Female U5 - 3/4” BSP Female CCU Output for RI - Remote indicator - T1/T2/T3/T4 (For Types, Refer Drawing) indication / Scada (Connected through external powersupply PSUs) If WTI please specify Transformer CT Secondary output..................(1A to 5A) Simulated Temperature rise over top oil........... (5°C to 30°C) Note: WTI Gradient is factory set. If required customer can adjust as per requirment. Sample Ordering Information :1005AHX\OTI\R4\S4\L\C6\U4\RI-T1........... Amps.............°C Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com MODEL - 1007 DIAL TYPE THERMOMETER Standard OTI / WTI General Features • The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and does not require any trimming or other periodic adjustments. • Instruments are fully compensated for ambient temperature. • The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A). • Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings and are provided with projection mounting clamps. • A maximum pointer facility is provided, can be reset from outside. • All switch contacts are potential free micro switches ML : 1007 Specifications Temperature Range Dial Size Dial angular Sweep Dial Graduation Accuracy Class Max.No. of Switches Switching Range Contact Rating Switch Differential Switching Accuracy Remote Repeater Max. Capillary Length Electrical Connection Degree of Protection High Voltage Test PSU Model : 1007 0-1500C, 0-1600C, 30-1500C,-20 to 1400C 115mm, Segment Dial 600 20C ±1.5% of FSD 4 15% - 85% 15A @ 250V AC 0.5A @ 250V DC Standard Micro switch S1 & S2: 3°C to 9°C (6±30C) Fixed S3 & S4: 8°C to 400C Adjustable. ±2.5 0C of Set Value Available (Potentiometer Output) Up to 25 Mtrs. Press Fit Wago Type IP – 55 (IEC-60529) 2.5 KV AC, 50Hz/60Hz for 1 minute; all Terminals to ground Electrical entry M20 - 3Nos Cable Gland Optional Thermometer Pocket Optional Remote Repeater 96 Sq Power Supply Unit - (PSU) a. Output Voltage: 24V b. Output Signal: Analogue output 2nos. 4-20mA DC (Output - 1, Burden 250 Ohms) (Output- 2, Burden 600 Ohms) c. Auxiliary supply: 90-260V AC/DC REMOTE INDICATOR a b d e f g h Type : 4 digits, 0.5’’ Seven Segment LED’s Auxiliary Supply : 90 – 260V AC/DC Resolution : 0.10C Degree of protection of enclosure : IP-20 Operating Temperature Range : 0°C to 60°C Signal output: 4sets of 4-20mA DC, Optional RS 485 Cutout Dimension: 92Sq.mm www.precimeasure.com DIAL TYPE Precimeasure Type Tested For 1. Protection class : IP55 as per IEC 60529 CAT 2. 2. Cold and Dry Test : -40°C to +70°C 3. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis 4. Salt Spray Test : For polyster powder coating and SS 304 Armour for 500 Hrs as per DIN 50021 Standard 5. Micro Switch rating Test : 15A @250V AC & 0.5A @250V DC Ordering Information Model Type of Instrument Range 1007 OTI / WTI R1. 0 - 150°C R2. 0 - 160°C R3. 30 - 150°C R4. -20 to140°C (other ranges on request) No. of Switches S2 - 2switches S3 - 3switches S4 - 4switches Switch Configuration L - Normally open contact L2 - Changeover contact Capillary Length C1 - 1mts C2 - 2mts....... upto C25 - 25mts Union Type U1 - 1/2“ BSP Male U2 - 3/4” BSP Male U3 - 1”BSP Male U4 - 1/2” BSP Female U5 - 3/4” BSP Female Repeater Y - Requried, N - Not Required If WTI please specify Transformer CT Secondary output..................(1A to 5A) Simulated Temperature rise over top oil........... (5°C to 30°C) Note: WTI Gradient is factory set. If required customer can adjust as per requirment. Sample Ordering Information :1007\OTI\R3\S2\L2\C8\U5\Y\........... Amps ...............°C Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com MODEL - 1007H DIAL TYPE THERMOMETER Hybrid OTI / WTI General Features • The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and does not require any trimming or other periodic adjustments. • Instruments are fully compensated for ambient temperature. • The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A). • Embedded PT-100 sensors in the sensing bulb of the local OTI/ WTI provide for a master indication. • Current Converter Unit (CCU) is mounted inside the Local OTI/WTI, The output from which can be connected to remote indicator or SCADA are a combination of both. • For the WTIs additional Winding temperature simulator is provided • Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings and are provided with projection mounting clamps. • A maximum pointer facility is provided, can be reset from outside. • All switch contacts are potential free micro switches ML : 1007H PSU Specifications Temperature Range Dial Size Dial angular Sweep Dial Graduation Accuracy Class Model : 1007H 0-1500C, 0-1600C, 30-1500C,-20 to 1400C 115mm, Segment Dial 600 20C ±1.5% of FSD Max.No. of Switches Switching Range Contact Rating 4 15% - 85% 15A @ 250V AC 0.5A @ 250V DC Standard Micro switch Switch Differential S1 & S2: 3°C to 9°C (6±30C) Fixed S3 & S4: 8°C to 400C Adjustable. Switching Accuracy Remote Indicator Max. Capillary Length Electrical Connection Degree of Protection High Voltage Test Electrical entry ±2.5 0C of Set Value Available / 4-20mA / RS - 485 Up to 25 Mtrs Press Fit Wago Type IP – 55(IEC-60529) 2.5 KV AC, 50Hz/60Hz for 1 minute; Switch connection & C.T. Terminal to ground. CCU output 0.5 Kv Ac 50Hz / 60Hz for 1 minute M20 - 3Nos Cable Gland Optional Thermometer Packet Optional Remote Repeater 96 Sq Power Supply Unit - (PSU) a. Output Voltage: 24V b. Output Signal: Analogue output 2nos. 4-20mA DC (Output - 1, Burden 250 Ohms) (Output- 2, Burden 600 Ohms) c. Auxiliary supply: 90-260V AC/DC REMOTE INDICATOR a b d e f g h Type : 4 digits, 0.5’’ Seven Segment LED’s Auxiliary Supply : 90 – 260V AC/DC Resolution : 0.10C Degree of protection of enclosure : IP-20 Operating Temperature Range : 0°C to 60°C Signal output: 4sets of 4-20mA DC, Optional RS 485 Cutout Dimension: 92Sq.mm www.precimeasure.com DIAL TYPE Precimeasure Type Tested For 1. Protection class : IP55 as per IEC 60529 CAT 2. 2. Cold and Dry Test : -40°C to +70°C 3. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis 4. Salt Spray Test : For polyster powder coating and SS 304 Armour for 500 Hrs as per DIN 50021 Standard 5. Micro Switch rating Test : 15A @250V AC & 0.5A @250V DC Ordering Information Model Type of Instrument Range 1007H OTI / WTI R1. 0 - 150°C R2. 0 - 160°C R3. 30 - 150°C R4. -20 to140°C (other ranges on request) No. of Switches S2 - 2switches S3 - 3switches S4 - 4switches Switch Configuration L - Normally open contact L2 - Changeover contact Capillary Length C1 - 1mts C2 - 2mts....... upto C25 - 25mts Union Type U1 - 1/2“ BSP Male U2 - 3/4” BSP Male U3 - 1”BSP Male U4 - 1/2” BSP Female U5 - 3/4” BSP Female CCU Output for RI - Remote indicator - T1/T2/T3/T4 (For types, refer Drawing) indication / Scada PSU - External power supply with 2 Nos. of 4-20mA output If WTI please specify Transformer CT Secondary output..................(1A to 5A) Simulated Temperature rise over top oil........... (5°C to 30°C) Note: WTI Gradient is factory set. If required customer can adjust as per requirment. Sample Ordering Information :1007H\OTI\R3\S2\L2\C8\U5\RI-T4........... Amps ...............°C Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com MODEL - 1006 DIAL TYPE THERMOMETER Standard OTI / WTI General Features • The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and does not require any trimming or other periodic adjustments. • Instruments are fully compensated for ambient temperature. • The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A). • Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings and are provided with projection mounting clamps. • A maximum pointer facility is provided, can be reset from outside. • All switch contacts are potential free micro switches. ML : 1006 Specifications Model : 1006 Temperature Range 0-1500C, 0-2400C Dial angular Sweep 2700 Dial Graduation 20C Accuracy Class ±1.5% of FSD Max.No. of Switches 2 Switching Range 15% - 85% Contact Rating 5A @ 250V AC, 0.5A @ 220V DC Switch Differential 10C to 50C (30C±20C) Fixed Switching Accuracy ±2.50C of Set Value Max. Capillary Length Up to 6 Mtrs. Switch Test Knob Available Electrical Connection 1Sq mm. Copper Cable, 1mtr Length Degree of Protection IP – 55(IEC-60529) High Voltage Test 2.5 KV AC, 50Hz / 60Hz for 1 minute ; all Terminal to ground www.precimeasure.com DIAL TYPE Precimeasure Type Tested For 1.Protection class : IP55 as per IEC 60529 CAT 2. 2.Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis 3.Salt Spray Test : For polyster powder coating and SS 304 Armour for 500 Hrs as per DIN 50021Standard 4.Micro Switch rating Test : 5A @ 250V AC, 0.5A @ 220V DC Ordering Information Model Type of Instrument Range 1006 OTI / WTI R1. 0 - 150°C. R2. 0 - 240°C No. of Switches S2 - 2switches Switch Configuration L - Normally open contact L2 - Changeover contact Capillary Length C1 - 1mts C2 - 2mts....... upto C6 - 6mts Union Type U1 - 1/2“ BSP Male U2 - 3/4” BSP Male U3 - 1” BSP Male U4 - 1/2” BSP Female U5 - 3/4” BSP Female If WTI please specify Transformer CT Secondary output ..................(1A to 5A) Simulated Temperature rise over top oil ........... (5°C to 30°C) Note: WTI Gradient is factory set. If required customer can adjust as per requirment. Sample Ordering Information :1006\WTI\R1\S2\L2\C5\U5 ........... Amps ...............°C Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com MODEL - 1006H DIAL TYPE THERMOMETER Hybrid OTI / WTI General Features • The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and does not require any trimming or other periodic adjustments. • Instruments are fully compensated for ambient temperature. • The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A). • Embedded PT-100 sensors in the sensing bulb of the local OTI/ WTI provide for a master indication. • Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings and are provided with projection mounting clamps. • A maximum pointer facility is provided, can be reset from outside. • All switch contacts are potential free micro switches. ML : 1006H Specifications Model : 1006H Temperature Range 0-1500C, 0-2400C Dial angular Sweep 2700 Dial Graduation 20C Accuracy Class ±1.5% of FSD Max.No. of Switches 2 Switching Range 15% - 85% 5A @ 250V AC, Contact Rating ML : 2220-R2 (CCU) 0.5A @ 220V DC Switch Differential 10C to 50C (30C±20C) Fixed Switching Accuracy ±2.50C of Set Value Remote Indicator Availbale Max. Capillary Length Up to 6 Mtrs. Switch Test Knob Available Electrical Connection 1Sq mm. Copper Cable, 1mtr Length Degree of Protection IP – 55(IEC-60529) High Voltage Test Test Voltage Terminals Details (a) Local OTI / WTI 2.5 KV AC, 50Hz / 60Hz Switch connection / CT Connection (b) Local OTI / WTI 500 V AC, 50Hz / 60Hz Pt 100 sensor output (c) CCU 500 V AC, 50Hz / 60Hz Pt 100 sensor input +4-20mA Output (d) CCU 2.5 KV AC, 50Hz / 60Hz CT connection with power supply Remote Indicator 96 Sq SPECIFICATION Type 4 digits, 0.5’’ Seven Segments LED’s Auxillary Supply 90 – 260V AC/DC Resolution 0.10C Degree of protection of enclosure IP 20 Operating Temperature Range 00C to 600C Signal output 4 sets of 4 - 20mA DC, Optional RS 485 Cutout dimension 92 Sq.mm www.precimeasure.com DIAL TYPE Precimeasure Type Tested For 1. Protection class : IP55 as per IEC 60529 CAT 2. 2. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis 3. Salt Spray Test : For polyster powder coating and SS 304 Armour for 500 Hrs as per DIN 50021 Standard 4. Micro Switch rating Test : 5A @ 250V AC, 0.5A @ 220V DC Ordering Information Model Type of Instrument Range 1006H OTI / WTI R1. 0 - 150°C. R2. 0 - 240°C No. of Switches S2 - 2switches Switch Configuration L - Normally open contact L2 - Changeover contact Capillary Length C1 - 1mts C2 - 2mts....... upto C6 - 6mts Union Type U1 - 1/2“ BSP Male U2 - 3/4” BSP Male U3 - 1” BSP Male U4 - 1/2” BSP Female U5 - 3/4” BSP Female If WTI please specify Transformer CT Secondary output..................(1A to 5A) Simulated Temperature rise over top oil........... (5°C to 30°C) Note:1) WTI Gradient is factory set. If required customer can adjust as per requirment. 2) External CCU and Remote Indicator is Part of the scheme. Sample Ordering Information :1006H\WTI\R1\S2\L\C3\U2 ........... Amps ...............°C Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com MODEL - 1006DH DIAL TYPE THERMOMETER for DRY TYPE TRANSFORMER Winding temperatures Indicator & Controller for Dry Type Transformers / Cast-Resin Transformers with built-in RTD scheme for Independent Remote indication and 4-20mA DC output for SCADA connection. Hybrid Instrument This is a high performance temperature Monitoring instrument with built-in PT-100 Sensor (RTD) & Current Converter Unit and external Remote indicator with built-in power supply unit General Features • The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and does not require any trimming or other periodic adjustments. • Instruments are fully compensated for ambient temperature. • Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings and are provided with projection mounting clamps. • A maximum pointer facility is provided, can be reset from outside. • All switch contacts are potential free micro switches ML : 1006DH Specifications Model : 1006DH Temperature Range 0-2400C Dial angular Sweep 2700 Dial Graduation 20C Accuracy Class ±1.5% of FSD Max.No. of Switches 2 Switching Range 15% - 85% Contact Rating 5A @ 250V AC, 0.5A @ 220V DC Switch Differential 10C to 50C (30C±20C) Fixed Switching Accuracy ±40C of Set Value Remote Indicator Availbale Max. Capillary Length Up to 6 mtrs Electrical Connection 1Sq mm. Copper Cable, 1mtr Length Degree of Protection IP – 55 (IEC-60529) High Voltage Test Switch Contact - 2.5KV AC,50Hz/60Hz for 1 Minute between Switch Terminals to ground CCU- 500V AC,50Hz/60Hz for 1 Minute between CCU Terminals to ground Power Supply Unit PSU Signal out put 2 nos 4-20 mA DC Aux Supply voltage 90-260V AC/DC Burden on signal output 600Ω max including loop resistance Temperature range 0-240°C Degree of protection IP-40 Digital Remote indicator Remote Indicator 96 Sq Temperature range 0-240°C Signal input 4-20 mA DC Aux Supply voltage 90-260V AC/DC Communication RS-485MODBUS RTU Communication (Optional) Degree of protection IP 20 Cutout Dimension 92 sq.mm www.precimeasure.com DIAL TYPE Precimeasure Type Tested For 1. Protection class : IP55 as per IEC 60529 CAT 2. 2. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis 3. Salt Spray Test : For polyster powder coating and SS 304 Armour for 500 Hrs as per DIN 50021 Standard 4. Micro Switch rating Test : 5A @ 250V AC, 0.5A @ 220V DC Ordering Information Model Type of Instrument Range No. of Switches Switch Configuration Capillary Length 1006DH WTI R1. 0 - 240°C S2 - 2switches L - Normally open contact L2 - Changeover contact C1 - 1mts C2 - 2mts....... upto C6 - 6mts Note: WTI Gradient is factory set. If required customer can adjust as per requirment. Sample Ordering Information :1006DH\WTI\R1\S2\L\C4 Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com MODEL - 1006HX DIAL TYPE THERMOMETER Duplex Hybrid OTI / WTI General Features • The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and does not require any trimming or other periodic adjustments. • Instruments are fully compensated for ambient temperature. • The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A). • Embedded Duplex PT-100 sensors in the sensing bulb of the local OTI/ WTI provide for a master indication. • This output can be connected to Remote Indicator or SCADA or combination of both. • WTI additional Winding temperature simulator is provided. • Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings and are provided with projection mounting clamps. • A maximum pointer facility is provided, can be reset from outside. • All switch contacts are potential free micro switches. ML : 1006HX Specifications Model : 1006HX Temperature Range 0-1500C, 0-2400C Dial angular Sweep 2700 Dial Graduation 20C Accuracy Class ±1.5% of FSD Max.No. of Switches 2 Switching Range 15% - 85% 5A @ 250V AC, Contact Rating PSU 0.5A @ 220V DC Switch Differential 10C to 50C (30C±20C) Fixed Switching Accuracy ±2.50C of Set Value Remote Indicator Availbale Max. Capillary Length Up to 6 Mtrs. Switch Test Knob Available Electrical Connection 1Sq mm. Copper Cable, 1mtr length Degree of Protection IP – 55(IEC-60529) High Voltage Test Test Voltage Terminals Details (a) Local OTI / WTI 2.5 KV AC, 50Hz / 60Hz Switch connection / CT Connection (b) Local OTI / WTI 500 V AC, 50Hz / 60Hz Pt 100 sensor output (c) CCU 500 V AC, 50Hz / 60Hz Pt 100 sensor input +4-20mA Output (d) CCU 2.5 KV AC, 50Hz / 60Hz CT connection with power supply Power Supply Unit - (PSU) a. Output Voltage: 24V b. Output Signal: Analogue output 2nos. 4-20mA DC (Maximum burden 600 Ohms Including Loop resistantance) c. Auxiliary supply: 90-260V AC/DC Remote Indicator 96 Sq REMOTE INDICATOR a b d e f g h Type : 4 digits, 0.5’’ Seven Segment LED’s Auxiliary Supply : 90 – 260V AC/DC Resolution : 0.10C Degree of protection of enclosure : IP-20 Operating Temperature Range : 0°C to 60°C Signal output: 4sets of 4-20mA DC, Optional RS 485 Cutout Dimension: 92Sq.mm www.precimeasure.com DIAL TYPE Precimeasure Type Tested For 1. Protection class : IP55 as per IEC 60529 CAT 2. 2. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis 3. Salt Spray Test : For polyster powder coating and SS 304 Armour for 500 Hrs as per DIN 50021 Standard 4. Micro Switch rating Test : a) ML - 1006HX: 5A @ 250V AC, 0.5A @ 220V DC Ordering Information Model Type of Instrument Range 1006HX OTI / WTI R1. 0 - 150°C. R2. 0 - 240°C No. of Switches S2 - 2switches Switch Configuration L - Normally open contact L2 - Changeover contact Capillary Length C1 - 1mts C2 - 2mts....... upto C6 - 6mts Union Type U1 - 1/2“ BSP Male U2 - 3/4” BSP Male U3 - 1” BSP Male U4 - 1/2” BSP Female U5 - 3/4” BSP Female CCU Output for RI - Remote indicator - T1/T2/T3/T4 (For types, Refer Drawing indication / Scada (Connected through external powersupply PSUs) If WTI please specify Transformer CT Secondary output..................(1A to 5A) Simulated Temperature rise over top oil........... (5°C to 30°C) Note: WTI Gradient is factory set. If required customer can adjust as per requirment. Sample Ordering Information :1006HX\OTI\R2\S2\L\C4\U1\RI-T3 ........... Amps ...............°C Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com MODEL - 1031 DIAL TYPE THERMOMETER Standard OTI / WTI General Features • The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and does not require any trimming or other periodic adjustments. • Instruments are fully compensated for ambient temperature. • The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A). • Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings and are provided with projection mounting clamps. • A maximum pointer facility is provided, can be reset from outside. • All switch contacts are potential free micro switches. ML : 1031 Specifications Model : 1031 Temperature Range 0-1500C Dial size 115mm, Segment Dial Dial angular Sweep 600 Dial Graduation 20C Accuracy Class ±1.5% of FSD Max.No. of Switches 2 Switching Range 15% - 85% Contact Rating 5A @ 250V AC 0.5A @ 220V DC Switch Differential 10C to 50C (30C±20C) Fixed Switching Accuracy ±2.50C of Set Value Max. Capillary Length Up to 6 Mtrs. Electrical Connection 1Sq mm. Copper Cable, 1mtr Length Degree of Protection IP – 55(IEC-60529) High Voltage Test 2.5KV AC, 50Hz/60Hz for 1 minute; All terminal to ground www.precimeasure.com DIAL TYPE Precimeasure Type Tested For Ordering Information 1. Protection class : IP55 as per IEC 60529 CAT 2. 2. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis 3. Salt Spray Test : For polyster powder coating and SS 304 Armour for 500 Hrs as per DIN 50021 Standard 4. Micro Switch rating Test : 5A @ 250V AC, 0.5A @ 220V DC Model Type of Instrument Range No. of Switches Switch Configuration Capillary Length Union Type If WTI please specify 1031 OTI / WTI R1. 0 - 150°C. S2 - 2switches L - Normally open contact L2 - Changeover contact C1 - 1mts C2 - 2mts....... upto C6 - 6mts U1 - 1/2“ BSP Male U2 - 3/4” BSP Male U3 - 1” BSP Male U4 - 1/2” BSP Female U5 - 3/4” BSP Female Transformer CT Secondary output ..................(1A to 5A) Simulated Temperature rise over top oil ........... (5°C to 30°C) Note: WTI Gradient is factory set. If required customer can adjust as per requirment. Sample Ordering Information :1031\OTI\R1\S2\L2\C6\U2 ........... Amps ...............°C Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com MODEL - 1031H DIAL TYPE THERMOMETER Hybrid OTI / WTI General Features • The fully sealed liquid expansion in the system provides a self powered indication and operation to the instruments, and does not require any trimming or other periodic adjustments. • Instruments are fully compensated for ambient temperature. • The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. • The WTIs are provided with gradient adjustment through a shunt for CT secondary input (1A to 5A). • Embedded PT-100 sensors in the sensing bulb of the local OTI/ WTI provide for a master indication. • Instrument cases are aluminium die casted and polyester powder coated. Each instrument has anti vibration mountings and are provided with projection mounting clamps. • A maximum pointer facility is provided, can be reset from outside. • All switch contacts are potential free micro switches. ML : 1031H Specifications Model : 1031H Temperature Range 0-1500C Dial Size 115mm, Segment Dial Dial angular Sweep 600 Dial Graduation 20C Accuracy Class ±1.5% of FSD Max.No. of Switches 2 Switching Range 15% - 85% 5A @ 250V AC, Contact Rating ML : 2220-R2 (CCU) 0.5A @ 220V DC Switch Differential 10C to 50C (30C±20C) Fixed Switching Accuracy ±2.50C of Set Value Remote Indicator Availbale Max. Capillary Length Up to 6 Mtrs. Electrical Connection 1Sq mm. Copper Cable, 1mtr Lenght Degree of Protection IP – 55(IEC-60529) High Voltage Test Test Voltage Terminals Details (a) Local OTI / WTI 2.5 KV AC, 50Hz / 60Hz Switch connection / CT Connection (b) Local OTI / WTI 500 V AC, 50Hz / 60Hz Pt 100 sensor output (c) CCU 500 V AC, 50Hz / 60Hz Pt 100 sensor input +4-20mA Output (d) CCU 2.5 KV AC, 50Hz / 60Hz CT connection with power supply SPECIFICATIONs Remote Indicator Type 4 digits, 0.5’’ Seven Segments LED’s Auxillary Supply 90 – 260V AC/DC Resolution 0.10C Degree of protection of enclosure IP 20 Operating Temperature Range 00C to 600C Signal output 4 sets of 4 - 20mA DC, Optional RS 485 Cutout dimension 92 Sq.mm www.precimeasure.com DIAL TYPE Precimeasure Type Tested For 1. Protection class : IP55 as per IEC 60529 CAT 2. 2. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis 3. Salt Spray Test : For polyster powder coating and SS 304 Armour for 500 Hrs as per DIN 50021 Standard 4. Micro Switch rating Test : 5A @ 250V AC, 0.5A @ 220V DC Ordering Information Model Type of Instrument Range No. of Switches Switch Configuration Capillary Length Union Type If WTI please specify 1031H OTI / WTI R1. 0 - 150°C. S2 - 2switches L - Normally open contact L2 - Changeover contact C1 - 1mts C2 - 2mts....... upto C6 - 6mts U1 - 1/2“ BSP Male U2 - 3/4” BSP Male U3 - 1” BSP Male U4 - 1/2” BSP Female U5 - 3/4” BSP Female Transformer CT Secondary output..................(1A to 5A) Simulated Temperature rise over top oil........... (5°C to 30°C) Note:1) WTI Gradient is factory set. If required customer can adjust as per requirment. 2) External CCU and Remote Indicator is Part of the scheme. Sample Ordering Information :1031H\WTI\R1\S2\L\C3\U2 ........... Amps ...............°C Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com Precimeasure DIAL TYPE BI - METALLIC THERMOMETER BI-METALLIC Bi-metallic type thermometer consists of Helical Bimetal Coil, which will expand or contract according to the temperature changes, which in turn operates indicating pointer. General Features a a a a a No external power supply required for indication or operation. Sealed system which requires no trimming or periodic site adjustments Directly mounted on the Transformer & Other Process Control Equipments. A maximum pointer facility is provided, can be reset from outside. The instruments are capable of working at an ambient temperature range of 00C to +600C. ML :1070 Model 1070 (Thermometer Without Contact, Top Mounting) SPECIFICATIONs Dial Angular Sweep Range Accuracy Graduation Instrument Case Segment Dial 1050 0-1200C (Other ranges on request) ±40C Between 400C & 1100C 20C per division PDC Aluminum Casting with Polyester Powder Coated. Model 1071 (Thermometer With 2 Contact, Top Mounting) SPECIFICATIONs Dial Angular Sweep Range Accuracy Graduation Instrument Case Segment Dial 1050 0-1200C (Other ranges on request) ±40C Between 400C & 1100C 20C per division PDC Aluminum Casting with Polyester Powder Coated. Max. Number of Switches Switch Type Switch Rating Switches Adjustable Range Accuracy of switch setting Switch Differential Range Contact Type Cable Gland (Polyamide / Brass) High Voltage Test ML :1071 2 Micro Switch 5A at 240V AC Normally Open Type or Changeover Type 200C – 1050C ±40C of Set Value 60C±30C Potential Free Cable Gland Size PG16 2KV AC, 50/60 Hz for 1 Minute, All terminals to ground www.precimeasure.com * The WTI instruments have a built in Thermal imaging system for transformer’s hot spot indication. * WTI Gradient calibration is factory set as per customer specification. If required, a provision is made for small adjustment at site. Model 1071 – WTI (Thermometer With 2 Contact, Top Mounting) Winding Temperature Indicator : SPECIFICATIONs ML :1071-WTI Dial Angular Sweep Range Accuracy Graduation Instrument Case Segment Dial 1050 0-1200C (Other ranges on request) ±40C Between 400C & 1100C 20C per division PDC Aluminum Casting with Polyester Powder Coated Max. Number of Switches Switch Type Switch Rating Switches Adjustable Range Switching Accuracy Switch Differential Contact Type Cable Gland (Polyamide / Brass) High Voltage Test 2 Micro Switch 5A at 240V AC Normally Open Type or Changeover Type 200C – 1050C ±40C of Set Value 60C±30C Potential Free Cable Gland Size PG11-2Nos 2KV AC, 50Hz for 1 Minute, All terminals to ground ML :1068 Model 1068 (4" Dial Thermometer With 2 Contact, Horizontal Mounting) SPECIFICATIONs Dial Angular Sweep Range Accuracy Graduation Instrument Case Round Dial 4’’ 1350 0-1200C (Other ranges on request) ±40C Between 400C & 1100C 20C per division PDC Aluminum Casting with Polyester Powder Coated Max. Number of Switches Switch Type Switch Rating Switches Adjustable Range Accuracy of switch setting Switch Differential Range Contact Type Cable Gland (Polyamide / Brass) High Voltage Test 2 Micro Switch 5A at 240V AC Normally Open Type or Changeover Type 400C – 1050C ±40C of Set Value 60C±30C Potential Free Cable Gland Size PG16 2KV AC, 50/60 Hz for 1 Minute, All terminals to ground Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com Precimeasure ML :1075 Model 1075 (3’’ Dial Horiozontal Mounting with Maximum Pointer) Specifications Dial Angular Sweep Range Accuracy Graduation Instrument Case Round Dial 3’’ 2400 0-1200C (Other ranges on request) ±40C Between 400C & 1100C 20C per division SS-304 Case (Natural Finish). ML :1073 / 1074 Model 1073 (4’’ Dial Top Mounting with Maximum Pointer) Specifications Dial Angular Sweep Range Accuracy Graduation Instrument Case Round Dial 4’’ 2400 0-1200C (Other ranges on request) ±40C Between 400C & 1100C 20C per division SS-304 Case (Natural Finish) Model 1074 (6’’ Dial Top Mounting with Maximum Pointer) Specifications Dial Angular Sweep Range Graduation Round Dial 6’’ 2400 0-1200C (Other ranges on request) ±40C Between 400C & 1100C 20C per division Instrument Case SS-304 Case (Natural Finish). Accuracy www.precimeasure.com BI-METALLIC DIAL TYPE BI - METALLIC THERMOMETER ML :1078 Model 1078 (3’’ Dial Top Mounting with Maximum Pointer) Specifications Dial Angular Sweep Range Accuracy Graduation Round Dial 3’’ 2400 0 -1200C (Other ranges on request) ±40C Between 400C & 1100C 20C per division Instrument Case SS-304 Case (Natural Finish). ML :1079 Model 1079 (3’’ Dial Entry at Angle 450 with Maximum Pointer) Specifications Dial Angular Sweep Range Accuracy Graduation Instrument Case Round Dial 3’’ 2400 0 -1200C ( Other ranges on request) ±40C Between 400C & 1100C 20C per division SS-304 Case (Natural Finish). All the Models Type Tested For : 1. Protection class : IP55 as per IEC 60529 CAT 2. 2. Salt Spray Test : Model-1068 / 1070 / 1071 For polyster powder coating 500 Hrs as per DIN 50021Standard Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com Precimeasure Electronic Temperature Controllers MODEL 2241B & 2242 WINDING TEMPERATURE INDICATOR / CONTROLLER FOR DRY TYPE TRANSFORMERS APPLICATION : MODEL 2241B/2242/2244T3 is designed for monitoring the temperatures of L.V. windings of the Dry-Type Transformer / Cast Resin Transformers. It will display winding temperatures and take necessary control action as per set and differential values programmed by the user. The protection system also records maximum temperatures and will display the same along with corresponding channel number whenever relevant push button is pressed. SALIENT FEATURES : a Power line filter with Fuse is incorporated in the input of the power supply to protect the equipment from High Energy Surge and Electrical Fast Transient. High Scanning Speed Remote Indication & Data Acquisition facility with burden upto 600 ohms. Optional RS-485 MODBUS RTU Communication Specifications Temperature Sensor input No. of Sensor inputs No. of Set-points ML :2241B Model 2241B RTD (Pt-100 DIN 43760) Model 2242 K Type thermocouples Three Four (Alarm, Trip, Fan1, Fan2) 00C – 2500C Range 00C -3000C 10C Resolution 0.10C 0 ±0.8%, one count under Accuracy ±1 C normal conditions. Display Speed User Settable (1-99 Seconds) 5 Seconds Display Six Nos. 0.5’’ Seven Segment LEDs Four nos 0.5” Seven Segment LEDs Auxiliary Supply Voltage 90-260 V AC/DC 0-20V AC or 0-240V AC Output Analogue output DC 4-20mA Analogue O/P DC (Maximum burden 600 Ohms) 0-1mA (10000 Ohms) 4-20mA(600 Ohms burden) Communication Isolated RS-485 MODBUS RTU RS-485 & RS-232 Communication (Optional). Communication Contact Rating @ 5A @ 220 VAC / 5A @ 30 DC Alarm & Trip 10A@120 Resistive Load VAC & 8A@240 VAC, Fan1 & Fan2 30A@120/240VAC Power Consumption 5 Watts 8 Watts Weight 2Kgs. Approx without packing box 2kgs Approx. without packing box Enclosure Aluminium Pressure Diecasting Panel Mount thru Cutout enclosure, powder coated all sides Indoor Mounting only with acrylic viewing window, IP-55 Temp : -300C to 550C Operating conditions Temp:-300C to 700C ML :2242 Four, Eight & Twelve Three (Fan, Alarm and Trip) Type Tested For Model: 2241B Model: 2242 1. Cold and Dry Test : -30°C to +70°C 1. 2. Vibration Test : 2. Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis Shock Test : 11ms/15g Procedure as per the IS: 13779 (12 shots) Vibration Test : Amplitude 0.5mm, Frequency 05 to 50Hz, 02 sweeps / X,Y,Z axis www.precimeasure.com ELECTRONIC a a a Electronic Temperature Controllers MODEL 2244T3 & 2253 WINDING TEMPERATURE INDICATOR / CONTROLLER FOR DRY TYPE TRANSFORMERS APPLICATION : MODEL 2244T3 & 2253 is designed for monitoring the temperatures of L.V. windings of the Dry-Type Transformer / Cast Resin Transformers. It will display winding temperatures and take necessary control action as per set and differential values programmed by the user. The protection system also records maximum temperatures and will display the same along with corresponding channel number whenever relevant push button is pressed. SALIENT FEATURES : a Power line filter with Fuse is incorporated in the input of the power supply to protect the equipment from High Energy Surge and Electrical Fast Transient. a a a High Scanning Speed Remote Indication & Data Acquisition facility with burden upto 600 ohms. Optional RS-485 MODBUS RTU Communication ML : 2244T3 specifications Temperature Sensor input No. of Sensor inputs No. of Set-points Range Resolution Accuracy Display Speed Display Auxiliary Supply Voltage Output Communication Contact Rating @ Resistive Load Power Consumption Weight Enclosure Operating conditions specifications Temperature Sensor input No. of Sensor inputs No. of Set-points Range Resolution Accuracy Display Speed Display Auxiliary Supply Voltage Output Communication Contact Rating @ Resistive Load Power Consumption Weight Enclosure Operating conditions RTD (PT-100 DIN 43760) one Two (Alarm,Trip) 00C – 2000C (Other Ranges on Request) 10C ±1% Three nos 0.5” Seven Segment LEDs 90-260V AC/DC (Other voltages on Request) Analogue output DC 4-20mA (Maximum burden 600 Ohms) 5A@220 VAC / 5A@30 VDC 2 Watts 0.5kgs Approx. without packing box. 96 Sq mm ABS Box Enclosure Panel Mount through Cutout, IP-20 Temp : 00C to 600C RTD (PT-100 DIN 43760) Four Three (Fan, Alarm and Trip) -20 to+3000C / 0 - 3000C 10C ±20C User Settable (1- 30 Seconds) 4 Nos. 0.5’’ Seven Segment LEDs 90-260 V AC/DC Analogue output DC 4-20mA (Maximum burden 600 Ohms) RS-485 MODBUS RTU Communication (Optional) 5A @ 220 VAC / 5A @ 30 VDC 5 Watts 0.5Kgs Approx without packing 96 Sq mm ABS Box Enclosure Panel Mount through Cutout, IP-20 Temp: 00C to 600C ML : 2253 Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com Electronic Temperature Controllers Precimeasure MODEL 2243A OTI / WTI TEMPERATURE INDICATOR / CONTROLLER APPLICATION : This scheme is used to Indicate Oil & Winding Temperature of the oil – immersed transformers. Relays are provided for Alarm, Trip and Cooler Duties, are operated as per the set value. 4-20mA DC signal outputs are provided separately for OTI & WTI for Remote Indication or SCADA Purpose. The System has the facility to store the maximum temperature attained. SCHEME CONSISTS OF : 1. PT -100 Sensor 1 No. 2. Electronic Temperature Controller 1 No. 3. Thermometer Pocket 1 No. (Optional) ML : 2243A Description Temperature Sensor input No. of sensor inputs CT Sec Current Input Temperature Rise No. of Set-points OTI No. of Set-points WTI Contact Rating Range Resolution Accuracy Display Auxiliary Supply Voltage Signal Outputs Type Tested For 1. Cold and Dry Test : -30°C to +70°C Power Consumption Weight Enclosure 2. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis Communication Operating Temperature Model: 2243A MODEL 2246 TAP Position Indicator SPECIFICATIONs Model 2246 Signal Input Range Display Auxiliary Supply Voltage Out put Resistance (1Kohms per step) 1-39 Position (User settable) 3 nos. 0.5” 7 Segment Leds 90-260 V AC/DC Four sets of 4-20 mA DC ( Maximum Burndon 600 Ohms) RS - 485 Modbus RTU Communication (Optional) 5 Watts (Max.) 0.5Kgs Approx. without packing 96 sq mm ABS Box Enclousure Panel Mount through cutout IP-20 00C to 600C Communication Power Consumption Weight Enclosure Operating Temperature Details RTD (Pt – 100 DIN 43760) ONE 1.0A to 5.0A (User Selectable) 10C to 450C (User Selectable) Two Relays for Alarm and Trip (1C/O SPDT Relay contacts) Four Relays for Alarm, Trip, Fan 1 and Fan 2 (1C/O SPDT Relay contacts) 5A @ 220 VAC / 5A @ 30 VDC Resistive Load 0-1500C 0.10C ±10C 0.5 Seven Segment LED Display 90-260 V AC/DC Two analogue Outputs (4-20mA Suitable for 600 Ohms Burdon) Each 1 No. 5 Watts (Max.) 2 Kgs Approx. without packing Aluminium Pressure Die Casting enclosure, powder coated with acrylic viewing window, IP-55 RS-485 MODBUS RTU (Optional) -300C to 700C ML : 2246 www.precimeasure.com ELECTRONIC SPECIFICATION : Electronic Temperature Controllers ELECTRONIC TYPE MODEL 2220-R1 & 2220-R2 TEMPERATURE INDICATOR APPLICATION : PRECIMEASURE Electronic Instruments are designed to indicate the Top Oil Temperature / Winding Temperature of the oil-immersed transformers in remote control room. This scheme has 2 Nos of 4-20 mA DC Signal outputs proportional to the temperature range. Signal OUTPUT – 1 is connected to an indicator for indicating temperature at remote and OUTPUT – 2 can be connected to Recorder or Data Acquisition System. SCHEME CONSISTS OF : 1. PT -100 Sensor 1 No. 2. Current Converter Unit 1 No. 3. Remote Indicator 1 No. 4. Thermometer Pocket 1 No. (Optional) SPECIFICATIONs : SL. 1 a. b. 2 Description Model 2220 – R1 Model 2220 – R2 PT 100 SENSOR ASSEMBLY Element : Simplex, 3 wire system / Duplex, 6 Wire System Tolerance : DIN 43760, Class ‘B’ CURRENT CONVERTER UNIT WITH POWER SUPPLY UNIT IP-55 Aluminium Casting. IP-40 ABS, DIN Enclosure Box. a b c d e f g Signal Input : PT 100 RTD, Simplex 3 wire Auxiliary Supply : 90 – 260V AC/DC Signal Outputs : 4 – 20mA DC corresponding to temperature range Burden on Output Signal : 600 Ohms maximum including loop resistance Accuracy of Signal Output : ±1% of F.S.D. Degree of protection of enclosure Casing 3 REMOTE INDICATOR a Type : 4 digits, 0.5’’ Seven Segment LED’s b Auxiliary Supply : 90 – 260V AC/DC c Temperature indicator range : 0-1500C (Other ranges on request) d Resolution : 0.10C e Degree of protection of enclosure : IP-20 Type Tested For Model: 2220-R1& 2220-R2 1. 2220-R1, Protection class : IP55 as per IEC 60529 CAT 2. 2. 2220-R2, Protection class: IP40 as per IEC 60529 CAT 2 3.Cold and Dry Teast : -30°C to +70°C 4.Vibration Test : Amplitude 1mm, frequency 50Hz,1Hr / X,Y,Z axis 5. EMI / EMC Test : a) Electrostatic Discharge Immunity Test as per IEC61000-4-2, 2001 b) Electrical Fast Transient Immunity Test as per IEC61000-4-4, 2004 c) High Energy Surge Immunity Test as per IEC61000-45, 2005 Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com MAGNETIC OIL LEVEL GUAGE Precimeasure Model 1080 - 4" & 6" APPLICATION: Magnetic Oil Level Gauge (MOG) is used to Measure Oil Level of oil filled Transformers & Oil filled Tanks. SPECIFICATIONS : Liquid in Tank Transformer oil to IS 335 and or any other Oil Working Temperature -30 to 100°C of oil Working Pressure 0 to 4 Kg / Cm2 Working Environment Indoor or Outdoor INDICATION : Dial size 4" & 6" Round Color Black marking on white background or any other combination as required. Standard Red Line Indication for Min. to Empty Level Angular Sweep 300° FLOAT (SENSOR) AND ARM : Material Float :Polyurethane Foam/Brass Float Arm : Brass Float-Arm Length Fixed Length as given by Customer Travel Max. 45° Below & Above from the centre Margin Leave Min. 40 mm beyond lower & higher limit markings to avoid striking of float to bottom & top of conservator. Type Micro switch Contact Rating 5A @ 240V AC, 0.25A 220V DC Type Tested For OTHERS SWITCH : Ordering Information 1. Protection class : IP55 as per IEC 60529 CAT 2. Model No 2. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis Conservator Diameter 1080/4 Float Arm Length Mounting Vertical/Inclined If Inclined Mention Angle And other Specifications if any MODEL: 1090 SIZE: 1” B.S.P MALE PRESSURE RELIEF DEVICE Application: PRD is a safety device for the distribution transformer up to 5000KVA, OLTC and other similar equipments. This PRD is used to prevent heavy damages of the tank in case of sudden rise of internal pressure. operating Pressure : Operating Pressure range available from 0.2 to 0.7 kg/sq.cm with tolerance ±0.05 kg/sq.cm. General Features • • • • • Safe spring loaded design that does not require external power supply for operation Positive downward directional flow limits horizontal spraying of hot oil on adjacent equipment Large diameter top cover with improved operating force providing better protection Transport safety clip to prevent oil spillage during transportation of oil filled transformers Available in brass or Zamak body construction www.precimeasure.com BEARING / AIR TEMPERATURE INDICATOR / CONTROLLER Precimeasure Model 1006 - BTD/ATD APPLICATION : This Instruments is used for monitoring and controlling the Bearing/ Air Temperature of the Motor and Generators Type Tested For SPECIFICATIONS : Temperature Range 0-150°C (Other Ranges on request) Dial Size 150mm (6") Round Dial Angular Sweep 270° Dial Graduations 2°C per Division Accuracy Class ±1.5% of F.S.D Max. No. of Switches 2 Switch Setting 15% to 85% Switch Contact Rating 5A at 250 V AC & 0.5A at 220V DC Switch Differential 3 °C± 2 C (Fixed) Accuracy of Switch Setting ±2.5°C of Set Value Max. Capillary Length Up to 15 Meters Mounting Flush / Projection 1. Protection class : IP55 as per IEC 60529 CAT 2. 2. Vibration Test : Amplitude 1mm, frequency 50Hz, 1Hr / X,Y,Z axis 3. Micro Switch rating Test : 5A @ 250V AC & 0.5A @ 220V DC PORTABLE OIL BATH Model HOB -180 For OTI & WTI Caliberation Display Specification Range Ambient +5°C To 180°C Display Dual 4 Digit Display Disply Resolution 0.1°C Temp-Setting With Push Button Data Entry General Specification System Acuracy Better Then ±0.5% Of Reading Or ±0.5%C (Which Ever Is Higher) Stability Better Then ±0.5%C Set Point Archive Time Approx. 30 Minutes Stabilization Time Approx. 20 Minutes After Reaching Set Value Electrical Specification Power Consumption 300 Watts Approx. Power Supply 230Vac, 50Hz Physical Specification Dimensions 6” (W) X 14” (H) X 9”(L) Weight 5.5 Kgs Approx. Heating Media Silicon Oil / Transformer Oil Oil Volume 1.5 Ltr Approx Well Depth 160 mm Accessories Drain Locking ‘O’ Ring Stirring By Mechanical Stirrer Of Ig Motor Precimeasure Controls Pvt. Ltd. Registered Office & Works : Branch Office & Works : Phone : + 91-80-4260 2705 / 08 Fax : + 91-80-4155 2205 E-Mail : sales–bng@precimeasure.com Phone : + 91-44-2250 0191 / 2250 0175 Fax : + 91-44-2250 0175 E-Mail : sales–chn@precimeasure.com No. 168/C Industrial Suburb, Peenya 3rd Phase, Bangalore - 560058. India No. 27,28,30, Block-II, 2nd Floor, Sidco Electronics Complex, Guindy, Chennai - 600032. India Western India Region Office : Mobile : 09377561070 E-Mail : sanjay@precimeasure.com www.precimeasure.com SCHEME Scheme drawing Precimeasure www.precimeasure.com Scheme drawing Precimeasure www.precimeasure.com