UniMatrix X-Band Solid State Power Amplifier System 1.86 - 6.6kW Indoor L/S C Ku Air or Liquid Cooled X Ka Power from 16 W to 10 kW GaN GaAs LDMOS Devices www.uniquesys.com UniMatrix X Band SSPA System Our new UniMatrix 1.86 - 6.6 kW X-Band modular system is designed using Gallium Nitride (GaN) RF device technology to deliver outstanding performance with improved efficiency, boosted reliability, and ease of maintenance. The system employes passive combining to avoid interruption in RF output power levels and can be controlled and monitored using either RS-485 or Ethernet. It is easily customizable between 4, 8 and 16 modules and can be configured as 1+1 (combined) or 1:1 (redundancy) system. This gives you the possibility to upgrade output power capabilities if requirements increase. * Hot Swappable SSPA Modules * Available output power up to 6.6 kW * Automatic gain control in case of single module failure X-Band 6.6kW SSPA System with 1+1 combining and and 1:1 reservation Available GaN module power levels SSPA Module Power 4-Module System 500W 1.86 kW (62.7 dBm) RF parameters Parameter Input frequency band Output frequency band Output power in redundancy mode 1:1 Output power in combining mode 1+1 Input power Power gain Conversion type Heterodyne frequency Gain variation vs. temperature 0º to +50º Gain adjustment Gain flatness External reference frequency 8-Module System 3.50 kW (65.5 dBm) 16-Module System 6.60 kW (68.2 dBm) Value 950 MHz – 1450 MHz 7900 MHz - 8400 MHz 65.5 dBm (3.50 kW) 68.2 dBm (6.60 kW) 0 dBm, max 70 dB, min, at minimum attenuator value One heterodyne, fixed frequency 6.95 GHz ± 2.5 dB, max 30 dB, min. with the step 0.5 dB ±2.5 dB, max, in the whole range ±1.0 dB, max, in any band 40 MHz of a specified frequency range 10 MHz, sinewave UniMatrix X Band SSPA System Parameter External reference frequency level Phase noise of external source Phase noise of output signal Third order Intermodulation (IMD3) Spurious harmonics Spurious radiation Output reflection level to enable protection Input RF signal monitoring port Output RF signal monitoring port (test load) Input signal source VSWR Load VSWR Group delay Residual radiation average power at 1m distance from the test load (with maximum radiation power on the load) Control and Indication AC power on/off (power supply units indication) Power interlock Gain adjustment range Overheat protection Output RF power Amplifier temperature, hottest spot Value (5+/-5) dBm -135 dBc/Hz, max, with offset 100 Hz -140 dBc/Hz, max, with offset 1 kHz -143 dBc/Hz, max, with offset 10 kHz -143 dBc/Hz, max, with offset 100 kHz - 60 dBc/Hz, max, with offset 100 Hz - 70 dBc/Hz, max, with offset 1 KHz - 80 dBc/Hz, max, with offset 10 KHz - 90 dBc/Hz, max, with offset 100 KHz - 33 dBc relative to carrier at 54dBm output power in combined mode and 51dBm in redundancy mode for the two carrier signals with 5 MHz separation - 55 dBс, max, relative to carrier (in the whole gain adjustment range), max. - 50 dBc, max., relative to carrier in all operation band - 10 dB, max. - 20 dB, max., relative to carrier, with indication on the display in Watts - 60 dB, relative to carrier, with calibration chart and display indication in Watts 1.5:1, max. 1.5:1, max. 1 ns at the max signal in the 40 MHz band - 58 dBm or less Switch (mechanical) Menu selection on/off RF power Menu selection: 30 dB, with 0.5 dB step +80 º С to +85º С at the hottest spot Output power display indication in W Centigrade º С temperature displayed UniMatrix X Band SSPA System Power Supply Parameter Input Power factor (cos φ) Power consumption, max Cooling Mechanical Parameters Outlay Value 190 to 260 V, 50 Hz ±10% 0.98 50 KW, max. Forced air ventilation (forced liquid cooling optional) 2 (two) 19´´ racks 42U with power amplifiers, 1 (one) waveguide assy with redundancy and combining system Connectors: RF input RF output Power supply N –type (female) WR112G 220/380V five-wire cable with 6 AWG cross section (three phases 220V, neutral and ground). Cable length to be confirmed Analog interface: For service maintenance of amplifier modules; For service maintenance of 1.2 kW power amplifier RS-485 interface Output RF signal monitoring port Chassis grounding DB-15 (female), front panel DB-15 (female), rear panel of the microcontroller DB-9 (female), rear panel N-type (female), waveguide, rear panel Grounding wire in the power supply cable UniMatrix X Band SSPA System Outline Drawings Wireless Broadband and Broadcasting Solutions Unique Broadband Systems Ltd. Part Number Configuration DPA Band YL – L-Band YS – S-Band YC – C-Band YX – X-Band KU – Ku-Band KA – Ka-Band Configuration/Options STD – Standard ISP – Input Sample Port WGF* – 90° Output W/G Flange WSP *– 90° Output W/G Flange with Input Sample Port Output Power L-Band 0250W,0500W S-Band 0150W, 0300W C-Band 0010W, 0020W, 0040W, 0080W,0100W, 0150W,0200W, 0250W,0300W, 0325W,0400W, 0650W,0800W X-Band 0275W, 0550W Ku-Band 0060W, 0080W,0100W, 0150W,0200W, 0300W,0400W, 0800W, Ka-Band TWTA, UP TO 1.5KW AVAILABLE PLEASE CALL FOR INQUIRY FOR HIGH POWER 1KW AND ABOVE PLEASE CONTACT OUR SALES DEPARTMENT FPS** – Front Panel Power Switch Sub Band L-Band A (1.0-2.0 GHz) B (1.5-3.0 GHz) C (1.0- 2.5 GHz) S-Band A (2.02-2.12 GHz) B (2.20-2.30 GHz) C-Band A (5.850-6.425 GHz) B (5.750-6.475 GHz) C (5.750-6.670 GHz) D (5.850-6.725 GHz) E (6.425-6.725 GHz) F (6.725-7.025 GHz) X-Band A (7.70-8.40 GHz) B (7.90-8.40 GHz) C (7.50-8.50 GHz) D (9.50-10.50 GHz) Ku-Band A (14.00-14.50 GHz) B (13.75-14.50 GHz) C (12.75-13.25 GHz) D (13.00-14.50 GHz) E (13.25-13.75 GHz) Ka-Band A (27.5-31.0 GHz) RPM – Reflected Power Monitor FRM** – Front Panel Power Switch and Reflected Power Monitor EPS – External, Redundant Power Supply, 1RU N+1 EPE – External Power Supply, 1RU N+1 and Rear Panel * Available in all but S-Band-and LBands ** Not Available with External 1RU N+1 Redundant Power Supply Block Up Converter B - BUC X – Not Available Enclosure I - Indoor O - Outdoor 400 Spinnaker Way Vaughan, Ontario L4K 5Y9 Canada www.uniquesys.com