TEST AND
MEASUREMENT
Important Information:
Whilst every precaution is taken to ensure the information contained herein is correct, Wattmaster accepts no liability whatsoever
for errors or omissions. In the interest of continuous improvement, Wattmaster reserves the right to change the specifications or
design of any of its products without prior notice. © Copyright 2012
Safety demands IEC 61010-1
As a professional user of test- and measuring equipment, your instruments must fulfill
current norms and guidelines. This includes CE standard, EMC and IEC10101/EN61010-1. Especially when measuring voltage and current is to be measured, it’s
important to fulfill IAC 1010-1 for correct category. This information are applied to all
relevant instruments, for example IEC 1010-1 CatIII 300V. Please be aware that the indi-
CAT
I
CAT
II
cated voltage is not the maximum voltage to be measured, but the maximum potential to ground. This will be 230V in standard household installations. The Low voltage
directive (LVD) describes safety required when measuring. If the equipment fulfill
IEC61010-1 / EN61010 and corresponding category, the LVD is said to be fulfilled.
CAT
CAT
III
IV
Main
switchboard
Meter
Shack
Main
switchboard
Meter
Earth bond
Shack
Main
switchboard
Transformer
Meter
Earth bond
Example:
CAT I
CAT II
CAT III
CAT IV
Electronic equipment and household appliances
with low energy
consumption
Outlets and sockets more than 10
meters from Cat
III or 20 meters
from Cat IV and
household appliances
Switch boards, fuse
boxes and electrical
installations.
Supply lines and
overhead power
lines, outdoor
installations and
cables in the
ground.
Elma 525 IEC 61010-1 Cat IV 1000V
Note: The indicated voltage is the maximum allowed potential between the instrument and neutral ground. Ie. that a 300V instrument can be used to measure 400V line to line voltage, because the potential to neutral ground is only 230V.
Methods of measuring – ground resistance
It’s important to verify the resistance to ground. Worst case scenario is injury or death, if the resistance to ground is not ok.
There are values and norms to fulfill. Therefore it’s important to be able to test and measure all connections and resistance to ground. When measuring the resistance of
earth bonds, one of the below methods are typically used.
R
S
T
N
S (Y)
E (X)
PE
RH
RT
H (Z)
TERRE
EXISTANTE
0%
62%
100%
GOOD TO KNOW - EARTH LOOP RESISTANCE
GOOD TO KNOW - THREE CONNECTION MEASUREMENT
This method demands a connection to line and neutral, as it is the earth bond of the
grid that are used as reference. Known as the two connection earth loop measurement.
The 62% method is the most precise method to measure resistance to earth. The
distance from E to H must be at least 5 times the length of the earth rod. For example if the rod is 2 meters in the ground, the distance between E and H must at least
be 10 meters. The distance from E to S is 62% of the total distance, in this example
6,2 meters.
It’s as easy and fast method, and no external probes are needed. The loop is measured through the grid and the transformer grounding. That means that the value will
typically be slightly higher than the clean resistance to earth from the rod.
Note: In large earth systems the diameter of the earth system is to seen as the length
of the earth rod.
Because of this the method is not suitable if a precise resistance is required.
Be aware that the result should be stable, if controlled by moving the S rod to 10%
more and then 10% less than 62%.
E (X)
H (Z)
S (Y)
ES (XV)
D
D
E (X)
H (Z)
S (Y)
ES (XV)
A
D
D
D
GOOD TO KNOW - EARTH RESISTIVITY
SCHLUMBERGER METHOD
The earth rod should be established where the earth conductivity is best. This can be
controlled by using the Wenner or the Schlumberger method. The unit for this type of
measurement is Ohmmeter. The CA6472 (page 61) automatically calculate the result,
the only information necessary for the instrument is the distance between the rods.
Used to determine the vertical conductivity and if it would be an advantage to extend
the rod deeper in the ground. When the distance between the outer rods, E and H is
extended, the measuring depth is extended.
The distance between the inner rods is A.
WENNER METHOD
Used to define the lateral placement of the earth rod. This identifies the best place
along a line to place the rod. The distance D between the rods must be the same.
ρW = 2 x π x d x RS - ES
The distance between the outer rods is 2 times D.
ρS = ( π x (d2 -A2 / 4) x RS - ES) / 4
TABLE OF CONTENTS
MULTIMETERS
POCKET DIGITAL MULTIMETER - WATTMASTER .......................................................................................................... 5
DIGITAL MULTIMETER - SAGAB....................................................................................................................................... 6
AUTO CHECK AC/DC DIGITAL MULTIMETER - ELMA .................................................................................................... 7
AC/DC DIGITAL MULTIMETER - WATTMASTER.............................................................................................................. 8
DIGITAL MULTIMETER - THEO BENNING........................................................................................................................ 9
STANDARD MM 400V AC/DC - ELMA ............................................................................................................................. 10
RMS MULTI METER WITH TEMP -20 - 300°C - ELMA.................................................................................................... 11
RMS W/AUTO CHECK, PC CONNECTIVITY & TEMP CATIII - ELMA ............................................................................ 12
1000V TRUE RMS AUTO CHECK W/PC CONNECTIVITY CATIV - ELMA ..................................................................... 13
INSULATION TESTER WITH MULTIMETER - ELMA ...................................................................................................... 14
DIGITAL MULTIMETER - WATTMASTER........................................................................................................................ 14
ANALOGUE MULTIMETER - WATTMASTER.................................................................................................................. 15
2-IN-1 INSULATION TESTER & MULTIMETER - ELMA .................................................................................................. 16
TEST LEADS SET FOR MULTIMETERS AND CLAMP METERS - WATTMASTER ....................................................... 17
CLAMP METERS
MINI DIGITAL CLAMP METER - WATTMASTER............................................................................................................. 17
MULTIFUNCTION DIGITAL METER - WATTMASTER .................................................................................................... 18
DIGITAL CLAMP MULTIMETER - WATTMASTER .......................................................................................................... 18
DIGITAL MULTIMETER - THEO BENNING...................................................................................................................... 19
DIGITAL CLAMP METER - ELMA..................................................................................................................................... 20
POWERCLAMP™ CLAMP METER - ELMA ..................................................................................................................... 21
CLAMP METER 200A OPEN JAW - ELMA ...................................................................................................................... 21
CLAMP METER 400A AC - ELMA .................................................................................................................................... 22
CLAMP METER 400A AC TRUE RMS - ELMA ................................................................................................................ 23
AC/DC DIGITAL CLAMP METER - ELMA ........................................................................................................................ 24
AUTO CHECK CLAMP-ON MULTIMETER - ELMA.......................................................................................................... 25
MINI DIGITAL CLAMP METER - ELMA ............................................................................................................................ 26
CLAMP METER 400A AC/DC TRUE RMS MINI - ELMA.................................................................................................. 26
DIGITAL CLAMP-ON METER - ELMA .............................................................................................................................. 27
TEST LEADS SET FOR MULTIMETERS AND CLAMP METERS - WATTMASTER ....................................................... 27
INSULATION TESTERS
ANALOGUE INSULATION TESTER - WATTMASTER .................................................................................................... 28
ANALOGUE INSULATION RESISTANCE TESTER - WATTMASTER ............................................................................ 28
ANALOGUE INSULATION TESTER - WATTMASTER .................................................................................................... 29
ANALOGUE INSULATION TESTER WITH RECHARGABLE BATTERY - ELMA ............................................................ 29
ANALOGUE INSULATION TESTER WITH 9V BATTERY - ELMA................................................................................... 30
2-IN-1 INSULATION TESTER & MULTIMETER - ELMA .................................................................................................. 31
INSULATION TESTER WITH MULTIMETER - ELMA ...................................................................................................... 32
DIGITAL RCD TESTER - ELMA........................................................................................................................................ 32
3
TABLE OF CONTENTS
VOLTAGE TESTERS
COMPACT VOLTAGE TESTER - THEO BENNING......................................................................................................... 33
EXPERT VOLTAGE TESTER - THEO BENNING ............................................................................................................ 33
DIGITAL PLUS VOLTAGE TESTER - THEO BENNING .................................................................................................. 34
ELECTRICAL VOLTAGE TESTER - WATTMASTER....................................................................................................... 35
AC/DC VOLTAGE TESTER - ELMA ................................................................................................................................. 35
VOLTAGE TESTER 690V AC/DC CAT IV 300V - ELMA.................................................................................................. 36
TEST SCREWDRIVERS/VOLTAGE TESTERS - WITTE ................................................................................................. 36
OTHER TESTERS
VS3 TRACKER/TROUBLESHOOTER - SAGAB .............................................................................................................. 37
POWER POINT AND EARTH LEAKAGE TESTER - WATTMASTER.............................................................................. 37
CABLE TRACER - WATTMASTER................................................................................................................................... 38
CIRCUIT BREAKER IDENTIFIER & FAULT FINDER - WATTMASTER .......................................................................... 38
CIRCUIT BREAKER IDENTIFIER 220-240VAC - WATTMASTER................................................................................... 39
LUX & FC LIGHT METER - WATTMASTER..................................................................................................................... 39
LIGHT METER 200LUX - ELMA ....................................................................................................................................... 40
INFRARED THERMO W/DOUBLE LASER 600°C - ELMA............................................................................................... 40
INFRARED THERMO W/DOUBLE LASER 1000°C - ELMA............................................................................................. 41
WIRELESS ENERGY CONTROL MONITOR - WATTMASTER....................................................................................... 41
TACHOMETER PHOTO/CONTACT - ELMA .................................................................................................................... 42
VOLT STICKS
VOLT STICK - SAGAB ...................................................................................................................................................... 42
MAGNET FIELD INDICATOR - SAGAB............................................................................................................................ 43
VOLT STICK FLAT TIP - SAGAB...................................................................................................................................... 43
VOLT STICK PRO - SAGAB ............................................................................................................................................. 44
VOLT STICK PRO 230 - SAGAB ...................................................................................................................................... 44
INTRINSICALLY SAFE VOLT STICK - SAGAB................................................................................................................ 45
50V VOLT STICK - SAGAB............................................................................................................................................... 45
4
MULTIMETERS
POCKET DIGITAL MULTIMETER ‐ WATTMASTER
FEATURES
• Non‐contact voltage indicator with sound.
• Pocket sized.
• Convenient built‐in case for easy storage of test leads.
• Built‐in test stand and auto power off.
• Auto‐ranging.
• Overload protection.
• Bargraph display.
Measuring circuit category:
Display count:
Indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Min resistance measuring range:
Max resistance measuring range:
Continuity resistor:
Diode test:
NCV indication range:
Dimensions:
Weight:
Inclusion:
CAT II 600V, CAT III 300V
3 1/2 digit, 3400
Digital
3.4 V
600 V
340 mV
600 V
340 Ohm
34 MOhm
340 Ohm
2V
70 ... 600 V
125x60x24mm
100 g
Operating instructions
Part No.
WAT115A
5
MULTIMETERS
DIGITAL MULTIMETER ‐ SAGAB
FEATURES
• Pocket sized multimeter with non‐contact voltage detection.
• Auto‐ranging and auto power off.
• Test probes can be attached to back of meter when not in use.
• Battery indication and handy back light for dim areas.
Measuring circuit category:
Display count:
Indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Max voltage measuring range, DC:
Lowest resolution, AC current:
Max current measuring range, AC:
Lowest resolution, DC current:
Max current measuring range, DC:
Min resistance measuring range:
Max resistance measuring range:
Min frequency measurement:
Max frequency measurement:
Min. capacitance measuring range:
Max capacitance measuring range:
NCV indication range:
Frequency measurement:
Dimensions:
Weight:
Inclusion:
CAT III 1000V
3 3/4 digit, 4000
Digital
4V
600 V
600 V
400 µA
0.2 A
400 µA
0.2 A
400 Ohm
40 MOhm
10 Hz
10 kHz
4 nF
200 µF
4 ... 600 V
Yes
104x55x32.5mm
145 g
Test leads, battery, carry case &
instructions
Part No.
WATDMM904
6
MULTIMETERS
AUTO CHECK AC/DC DIGITAL MULTIMETER ‐ ELMA
FEATURES
• Intelligent 'auto check' feature automatically detects and selects
AC/DC voltage function etc.
• Auto‐ranging and auto power off.
• Data hold function and overload protection.
• With non‐contact voltage indication.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, carry case and operating
instructions.
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Lowest resolution, resistance:
Max resistance measuring range:
Min frequency measurement:
Max frequency measurement:
Min. capacitance measuring range:
Max capacitance measuring range:
Min continuity resistor range:
Max continuity resistor range:
NCV indication range:
Frequency measurement:
Dimensions:
Weight:
CAT II 600V, CAT III 300V
3 5/6 digit, 6000
6V
600 V
6V
600 V
600 Ohm
40 MOhm
10 Hz
100 kHz
100 nF
2000 µF
50 Ohm
300 Ohm
15 ... 190 V
Yes
113x53x10mm
80 g
Part No.
WATEL-25
7
MULTIMETERS
AC/DC DIGITAL MULTIMETER ‐ WATTMASTER
FEATURES
• Hand held digital meter with ruggedised body for shock protection.
• Fuse protected.
• Safety input jacks.
• Overload protection.
• Wrong input buzzer warning.
Measuring circuit category:
Display count:
Indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Lowest resolution, AC current:
Max current measuring range, AC:
Lowest resolution, DC current:
Max current measuring range, DC:
Min resistance measuring range:
Max resistance measuring range:
Min frequency measurement:
Max frequency measurement:
Continuity resistor:
Diode test:
Frequency measurement:
Dimensions:
Weight:
Inclusion:
CAT III 1000V
3 1/2 digit, 1999
Digital
200 mV
750 V
200 mV
1000 V
200 µA
20 A
200 µA
20 A
200 Ohm
2000 MOhm
2 kHz
40 kHz
100 Ohm
2V
Yes
198x90x44mm
400 g
Test leads, spare fuse & instructions
Part No.
WATDMM9001
8
MULTIMETERS
DIGITAL MULTIMETER ‐ THEO BENNING
FEATURES
• Pen‐type multimeter with AC current transducer.
• Auto‐ranging.
• Low battery warning.
• Robust housing due to integrated protective rubber frame.
• IEC 61010‐1.
• IP30 rating.
Measuring circuit category:
Display count:
Indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Max current measuring range, AC:
Min resistance measuring range:
Max resistance measuring range:
Continuity resistor:
Diode test:
Pliers opening:
Dimensions:
Weight:
Inclusion:
CAT III 300V
3 3/4 digit, 4200
Digital
4.2 V
600 V
4.2 V
600 V
300 A
420 Ohm
42 MOhm
50 Ohm
1V
30 mm
145x52x34mm
100 g
Test leads, battery, carry case &
instructions
Part No.
WAT044073
9
MULTIMETERS
STANDARD MM 400V AC/DC ‐ ELMA
FEATURES
• Professional grade, rugged test meter.
• Measures Voltage, Current, Frequency, Resistance, Capacitance,
Diodes and Continuity.
• Faulty Connection Warning.
• Highly efficient fuses.
• Automatic Range Selection.
• Relative Measurement.
• Max & Data Hold.
• Compliant with IEC 61010‐1 CAT III 600V.
• Supplied complete with manual, battery, test leads and robust
rubber protective cover.
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Lowest resolution, AC current:
Max current measuring range, AC:
Lowest resolution, DC current:
Max current measuring range, DC:
Lowest resolution, resistance:
Max resistance measuring range:
Min frequency measurement:
Max frequency measurement:
Min. capacitance measuring range:
Max capacitance measuring range:
Min continuity resistor range:
Max continuity resistor range:
Diode test:
Dimensions:
Weight:
CAT III 600V, CAT II 1000V
3 3/4 digit, 4000
400 mV
1000 V
400 mV
1000 V
400 µA
10 A
400 µA
10 A
400 Ohm
40 MOhm
50 Hz
1 MHz
500 nF
3000 µF
10 Ohm
120 Ohm
1.6 V
186x87x45mm
390 g
Part No.
WATEL-805
10
MULTIMETERS
RMS MULTI METER WITH TEMP ‐20 ‐ 300DEG ‐ ELMA
FEATURES
• Handheld digital meter with ruggedised body.
• Auto‐ranging and auto power off.
• Data hold function and overload protection.
• Wrong input warning.
• Highly efficient fuses.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, carry case and operating
instructions.
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Lowest resolution, AC current:
Max current measuring range, AC:
Lowest resolution, DC current:
Max current measuring range, DC:
Lowest resolution, resistance:
Max resistance measuring range:
Min frequency measurement:
Max frequency measurement:
Min. capacitance measuring range:
Max capacitance measuring range:
Temperature range:
Min continuity resistor range:
Max continuity resistor range:
Diode test:
Dimensions:
Weight:
CAT III 600V, CAT II 1000V
3 3/4 digit, 4000
400 mV
1000 V
400 mV
1000 V
400 µA
10 A
400 µA
10 A
400 Ohm
40 MOhm
50 Hz
1 MHz
500 nF
3000 µF
-20 ... 300 °C
10 Ohm
120 Ohm
1.6 V
198x97x55mm
400 g
Part No.
WATEL-807
11
MULTIMETERS
RMS W/AUTO CHECK, PC CONNECTIVITY & TEMP CATIII ‐ ELMA
FEATURES
• Handheld digital meter with ruggedised body.
• Auto‐ranging and auto power off.
• Data hold function and overload protection.
• Wrong input warning.
• True RMS and temperature measurement.
• Highly efficient fuses and handy backlight for dim areas.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, carry case and operating
instructions.
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Lowest resolution, AC current:
Max current measuring range, AC:
Lowest resolution, DC current:
Max current measuring range, DC:
Lowest resolution, resistance:
Max resistance measuring range:
Min frequency measurement:
Max frequency measurement:
Min. capacitance measuring range:
Max capacitance measuring range:
Temperature range:
Min continuity resistor range:
Max continuity resistor range:
Diode test:
NCV indication range:
Dimensions:
Weight:
CAT III 600V
3 5/6 digit, 6000
60 mV
1000 V
60 mV
1000 V
600 µA
8A
600 µA
8A
600 Ohm
60 MOhm
10 Hz
100 kHz
60 nF
3000 µF
-50 ... 1000 °C
10 Ohm
80 Ohm
1V
20 ... 1000 V
161x80x50mm
340 g
Part No.
WATEL-BM257
12
MULTIMETERS
1000V TRUE RMS AUTO CHECK W/PC CONNECTIVITY CATIV ‐ ELMA
FEATURES
• Handheld digital meter with ruggedised body.
• Intelligent 'auto check' feature automatically detects and selects
AC/DC voltage function etc.
• Auto‐ranging and auto power off.
• With PC connection‐ can be used for data logging purposes.
• Data hold function and overload protection.
• True RMS and temperature measurement.
• Highly efficient fuses and handy backlight for dim areas.
• With non‐contact voltage indication.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, rubber cover, batteries, temperature sensor
and operating instructions.
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Lowest resolution, AC current:
Max current measuring range, AC:
Lowest resolution, DC current:
Max current measuring range, DC:
Lowest resolution, resistance:
Max resistance measuring range:
Min frequency measurement:
Max frequency measurement:
Min. capacitance measuring range:
Max capacitance measuring range:
Temperature range:
Min continuity resistor range:
Max continuity resistor range:
Diode test:
NCV indication range:
Dimensions:
Weight:
CAT IV 1000V
4 digit, 9999
60 mV
1000 V
60 mV
1000 V
600 µA
10 A
600 µA
10 A
600 Ohm
60 MOhm
10 Hz
100 kHz
60 nF
25 mF
-50 ... 1000 °C
20 Ohm
300 Ohm
2V
20 ... 440 V
208x103x65mm
640 g
Part No.
WATEL-BM829
13
MULTIMETERS
INSULATION TESTER WITH MULTIMETER ‐ ELMA
FEATURES
• 2‐in‐1 multimeter and insulation tester.
• Handheld digital meter with ruggedised body.
• Low battery indication.
• Auto‐ranging and auto power off.
• Easy to read illuminated display screen.
• Data hold function and overload protection.
• Automatic discharge of capacitive voltage.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, rubber cover, batteries, carry case and
operating instructions.
Measuring circuit category:
Max voltage measuring range, AC:
Max voltage measuring range, DC:
Min resistance measuring range:
Lowest resolution, resistance:
Max resistance measuring range:
Min continuity resistor range:
Max continuity resistor range:
Insulation resistance measuring range:
Data hold:
Dimensions:
Weight:
CAT III 1000V, CAT IV 600V
750 V
1000 V
0 Ohm
40 Ohm
0.0004 MOhm
40 Ohm
400 Ohm
4 ... 4000 MOhm
Yes
200x92x50mm
700 g
Part No.
WATEL-DT5500A
DIGITAL MULTIMETER ‐ WATTMASTER
FEATURES
• Ideal as a first multimeter.
• Compact size.
• Transistor and battery test.
• Overload protection.
• Low battery indication.
Measuring circuit category:
Display count:
Indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Lowest resolution, DC current:
Max current measuring range, DC:
Min resistance measuring range:
Max resistance measuring range:
Temperature range:
Continuity resistor:
Diode test:
Temperature measurement:
Dimensions:
Weight:
Inclusion:
CAT II 500V
3 1/2 digit, 1999
Digital
200 V
750 V
200 mV
1000 V
200 µA
10 A
200 Ohm
2 MOhm
-40 ... 1000 °C
70 Ohm
2.4 V
Yes
150x70x24mm
150 g
Test leads & instructions
Part No.
WATQM-1500
14
MULTIMETERS
ANALOGUE MULTIMETER ‐ WATTMASTER
FEATURES
• Easy to read three colour scale for error‐proof readings.
• With built‐in test stand.
• Transistor test.
• Fuse and diode protection.
Measuring circuit category:
Indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Lowest resolution, DC current:
Max current measuring range, DC:
Min resistance measuring range:
Max resistance measuring range:
Continuity resistor:
Dimensions:
Weight:
Inclusion:
CAT II 1000V
Analogue
10 V
1000 V
100 mV
1000 V
50 µA
10 A
20 Ohm
0.2 MOhm
120 Ohm
148x100x35mm
280 g
Test leads, battery & instructions
Part No.
WATQM-1020
15
MULTIMETERS
2‐IN‐1 INSULATION TESTER & MULTIMETER ‐ ELMA
FEATURES
• 2‐in‐1 insulation tester and multimeter.
• Large backlight display allows for all measurements to be viewed at
the same time.
• Low battery indication and data hold function.
• Auto‐ranging and auto power off.
• True RMS.
• Store and recall button allows you to store values and recall them
later.
• With PC connection ‐ can be used for data logging purposes.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, USB cable, software, carry case
and operating instructions.
• Protection class: IP67 (dust‐tight/liquid‐tight)
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Lowest resolution, AC current:
Max current measuring range, AC:
Lowest resolution, DC current:
Max current measuring range, DC:
Lowest resolution, resistance:
Max resistance measuring range:
Min frequency measurement:
Max frequency measurement:
Min. capacitance measuring range:
Max capacitance measuring range:
Temperature range:
Continuity resistor:
Min continuity resistor range:
Max continuity resistor range:
Diode test:
Frequency measurement:
Dimensions:
Weight:
CAT III 1000V, CAT IV 600V
10 digit, 40000
400 mV
1000 V
400 mV
1000 V
400 µA
10 A
400 µA
10 A
400 Ohm
40 MOhm
40 Hz
100 MHz
40 nF
40 mF
-50 ... 1000 °C
400 Ohm
35 Ohm
400 Ohm
2.8 V
Yes
220x97x61mm
630 g
Part No.
WATEL-5800
16
MULTIMETERS
TEST LEADS SET FOR MULTIMETERS AND CLAMP METERS ‐ WATTMASTER
FEATURES
• Test lead set for Wattmaster WATDMM and WATDCM range of
meters.
Type of accessory:
Testlead
Part No.
WATTLS
CLAMP METERS
MINI DIGITAL CLAMP METER ‐ WATTMASTER
FEATURES
• Clamp meter with non‐contact voltage detection.
• True RMS and auto power off.
• Auto‐ranging and data hold function.
• Overload protection.
• Handy backlight for dim areas.
Measuring circuit category:
Display count:
Indication:
Pliers opening:
Current measurement range, AC:
Min resistance measuring range:
Max resistance measuring range:
Min. capacitance measuring range:
Max capacitance measuring range:
Temperature range:
Continuity resistor:
NCV indication range:
Type of current:
Voltage measurement, DC:
Voltage measurement, AC:
True RMS measurement:
Resistance measurement range:
Capacitance measurement:
Dimensions:
Weight:
Inclusion:
CATIII 300V, CAT III 600V
3 3/4 digit, 3999
Digital
30 mm
40 ... 400 A
0 Ohm
4 MOhm
4 µF
4 mF
-35 ... 400 °C
400 Ohm
24 ... 600 V
Alternating current
Yes
Yes
Yes
Yes
Yes
200x65x39mm
200 g
Test leads, carry case & instructions
Part No.
WATDCM1046
17
CLAMP METERS
MULTIFUNCTION DIGITAL METER ‐ WATTMASTER
FEATURES
• Clamp meter with non‐contact voltage detection.
• True RMS and auto power off.
• Data hold function.
• Overload protection.
Indication:
Contact less:
Digital
Yes
Part No.
WATDCM1065
DIGITAL CLAMP MULTIMETER ‐ WATTMASTER
FEATURES
• Ruggedised body for shock absorption.
• Auto‐ranging and auto power off.
• Data hold function.
• Overload protection on all ranges.
• True RMS.
Indication:
Voltage type:
True RMS measurement:
Digital
AC/DC
Yes
Part No.
WATDCM2606
18
CLAMP METERS
DIGITAL MULTIMETER ‐ THEO BENNING
FEATURES
• Pen‐type multimeter with AC current transducer.
• Auto‐ranging.
• Low battery warning.
• Robust housing due to integrated protective rubber frame.
• IEC 61010‐1.
• IP30 rating.
Measuring circuit category:
Display count:
Indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Max current measuring range, AC:
Min resistance measuring range:
Max resistance measuring range:
Continuity resistor:
Diode test:
Pliers opening:
Dimensions:
Weight:
Inclusion:
CAT III 300V
3 3/4 digit, 4200
Digital
4.2 V
600 V
4.2 V
600 V
300 A
420 Ohm
42 MOhm
50 Ohm
1V
30 mm
145x52x34mm
100 g
Test leads, battery, carry case &
instructions
Part No.
WAT044073
19
CLAMP METERS
DIGITAL CLAMP METER ‐ ELMA
FEATURES
• Compact and handy digital clamp meter with temperature
measurement.
• Twin display screen allows for simultaneous electrical and
temperature measurement ie measure voltage and current at the same time.
• Auto‐ranging and auto power off.
• Data hold function and overload protection.
• 26mm max jaw opening size.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, temperature sensor, carry case
and operating instructions.
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Current measurement range, AC:
Min resistance measuring range:
Max resistance measuring range:
Min. capacitance measuring range:
Max capacitance measuring range:
Min frequency measurement:
Max frequency measurement:
Temperature range:
Continuity resistor:
Continuity resistor range:
Diode test:
Voltage measurement, DC:
Voltage measurement, AC:
Resistance measurement range:
Dimensions:
Weight:
CAT III 600V
3 3/4 digit, 3999 (x2 dual screen)
4V
600 V
400 mV
600 V
40 ... 400 A
400 Ohm
40 MOhm
500 nF
3000 µF
5 Hz
100 kHz
-20 ... 300 °C
120 Ohm
0.02 ... 12 kOhm
1.6 V
Yes
Yes
Yes
190x63x32mm
190 g
Part No.
WATEL-126
20
CLAMP METERS
POWERCLAMP™ CLAMP METER ‐ ELMA
FEATURES
• Intelligent 'auto check' feature automatically detects and selects
AC/DC voltage function etc.
• Auto‐ranging and auto power off.
• Dual backlight display.
• With PC connection‐ can be used for data logging purposes.
• Data hold function and overload protection.
• 45mm max jaw opening size.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, carry case and operating
instructions.
• THD: 0‐999%.
Measuring circuit category:
Display count:
Measuring range selection:
Max voltage measuring range, AC:
Max voltage measuring range, DC:
Current measurement range, AC:
Max resistance measuring range:
Min frequency measurement:
Max frequency measurement:
Temperature range:
Continuity resistor:
Continuity resistor range:
Voltage type:
Type of current:
Voltage measurement, DC:
Voltage measurement, AC:
Dimensions:
Weight:
CAT III 600V
4 digit, 9999
Automatic
600 V
600 V
40 ... 1000 A
0.001 MOhm
5 Hz
500 kHz
-50 ... 300 °C
300 Ohm
0.01 ... 3 kOhm
AC/DC
Alternating current
Yes
Yes
224x78x40mm
225 g
Part No.
WATEL-155
CLAMP METER 200A OPEN JAW ‐ ELMA
FEATURES
• Open jaw type clamp meter and non‐contact voltage tester in one.
• True RMS.
• 'VoltSense' non‐contact voltage detection measured by passing open
jaw against cable.
• Auto‐ranging and auto power off.
• Data hold function and overload protection.
• Easy to use single rotary switch for function selection.
• 16mm max jaw opening size.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, carry case and operating
instructions.
Display count:
Diode test:
Voltage measurement, DC:
Voltage measurement, AC:
Weight:
3 1/2 digit, 1999
3V
Yes
Yes
280 g
Part No.
WATEL-2500
21
CLAMP METERS
CLAMP METER 400A AC ‐ ELMA
FEATURES
• Small and handy digital clamp meter.
• Auto‐ranging and auto power off.
• Data hold function and overload protection.
• Low battery warning.
• 26mm max jaw opening size.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, carry case, sample loops and
operating instructions.
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Current measurement range, AC:
Min resistance measuring range:
Max resistance measuring range:
Min. capacitance measuring range:
Max capacitance measuring range:
Min frequency measurement:
Max frequency measurement:
Continuity resistor:
Continuity resistor range:
Diode test:
Voltage measurement, DC:
Voltage measurement, AC:
Resistance measurement range:
Dimensions:
Weight:
CAT III 600V
3 3/4 digit, 4000
4V
600 V
400 mV
600 V
40 ... 400 A
400 Ohm
40 MOhm
500 nF
3000 µF
5 Hz
100 kHz
120 Ohm
0.02 ... 12 kOhm
1.6 V
Yes
Yes
Yes
190x63x32mm
190 g
Part No.
WATEL-3036
22
CLAMP METERS
CLAMP METER 400A AC TRUE RMS ‐ ELMA
FEATURES
• Small and handy digital clamp meter with true RMS.
• Auto‐ranging and auto power off.
• Data hold function and overload protection.
• Low battery warning.
• 26mm max jaw opening size.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, carry case, sample loops and
operating instructions.
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Current measurement range, AC:
Min resistance measuring range:
Max resistance measuring range:
Min. capacitance measuring range:
Max capacitance measuring range:
Min frequency measurement:
Max frequency measurement:
Continuity resistor:
Continuity resistor range:
Diode test:
Voltage measurement, DC:
Voltage measurement, AC:
Dimensions:
Weight:
CAT III 600V
3 3/4 digit, 4000
4V
600 V
400 mV
600 V
40 ... 400 A
400 Ohm
40 MOhm
500 nF
3000 µF
5 Hz
100 kHz
120 Ohm
0.02 ... 12 kOhm
1.6 V
Yes
Yes
190x63x32mm
190 g
Part No.
WATEL-3038
23
CLAMP METERS
AC/DC DIGITAL CLAMP METER ‐ ELMA
FEATURES
• Professional grade clamp meter suitable for troubleshooting and
preventative measurements on installations.
• True RMS.
• Flexible and robust design with large backlight display.
• Auto‐ranging and auto power off.
• Data hold function and overload protection.
• Easy to use single rotary switch for function selection.
• 30mm max jaw opening size.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, temperature probe, batteries, carry case
and operating instructions.
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Current measurement range, AC:
Current measurement range, DC:
Min resistance measuring range:
Max resistance measuring range:
Min. capacitance measuring range:
Max capacitance measuring range:
Min frequency measurement:
Max frequency measurement:
Temperature range:
Continuity resistor:
Continuity resistor range:
Diode test:
Voltage measurement, DC:
Voltage measurement, AC:
Resistance measurement range:
Dimensions:
Weight:
CAT IV 600V, CAT III 1000V
3 5/6 digit, 6000
6V
1000 V
600 mV
1000 V
60 ... 600 A
60 ... 600 A
600 Ohm
60 MOhm
40 nF
4000 µF
100 Hz
60 kHz
-20 ... 760 °C
60 Ohm
0 ... 6 kOhm
2.8 V
Yes
Yes
Yes
215x74x43mm
285 g
Part No.
WATEL-9015
24
CLAMP METERS
AUTO CHECK CLAMP‐ON MULTIMETER ‐ ELMA
FEATURES
• Handheld digital clamp‐on meter with ruggedised body.
• Intelligent 'auto check' feature automatically detects and selects
AC/DC voltage function etc.
• Auto‐ranging and auto power off.
• Large LCD display screen.
• Data hold function and overload protection.
• With non‐contact voltage indication.
• 45mm max jaw opening size.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, carry case and operating
instructions.
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Lowest resolution, AC current:
Max current measuring range, AC:
Min resistance measuring range:
Lowest resolution, resistance:
Max resistance measuring range:
Min frequency measurement:
Max frequency measurement:
Min. capacitance measuring range:
Max capacitance measuring range:
Continuity resistor:
Min continuity resistor range:
Max continuity resistor range:
Diode test:
NCV indication range:
Dimensions:
Weight:
CAT III 600V
3 5/6 digit, 6000
6V
600 V
6V
600 V
400A
2000 A
600 Ohm
600 Ohm
6 MOhm
10 Hz
1 kHz
100 nF
2000 µF
300 Ohm
10 Ohm
300 Ohm
1.6 V
15 ... 300 V
224x78x40mm
220 g
Part No.
WATEL-BM117
25
CLAMP METERS
MINI DIGITAL CLAMP METER ‐ ELMA
FEATURES
• Small and handy digital clamp meter ideal for works in crowded
switch boxes or cable areas etc.
• Auto‐ranging and auto power off.
• Data hold function and overload protection.
• Easy to use single rotary switch for function selection.
• 24mm max jaw opening size.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, carry case and operating
instructions
Measuring circuit category:
Display count:
Max voltage measuring range, AC:
Max voltage measuring range, DC:
Current measurement range, AC:
Current measurement range, DC:
Min resistance measuring range:
Max resistance measuring range:
Min frequency measurement:
Max frequency measurement:
Continuity resistor:
Continuity resistor range:
Voltage measurement, DC:
Voltage measurement, AC:
Dimensions:
Weight:
CAT III 300V, CAT II 600V
3 3/4 digit, 3999
400 V
400 V
40 ... 200 A
40 ... 200 A
40 Ohm
0.0004 MOhm
1 Hz
100 kHz
400 Ohm
0.04 ... 4 kOhm
Yes
Yes
183x64x36mm
190 g
Part No.
WATEL-CM01
CLAMP METER 400A AC/DC TRUE RMS MINI ‐ ELMA
FEATURES
• Handheld digital meter with ruggedised body.
• Intelligent 'auto check' feature automatically detects and selects
AC/DC voltage function etc.
• Auto‐ranging and auto power off.
• Data hold function and overload protection.
• True RMS.
• Highly efficient fuses and handy backlight for dim areas.
• With non‐contact voltage indication.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, rubber cover, batteries, bag and operating
instructions.
Measuring circuit category:
Display count:
Current measurement range, AC:
Current measurement range, DC:
Min frequency measurement:
Max frequency measurement:
Dimensions:
Weight:
CAT III 300V, CAT II 600V
3 3/4 digit, 3999
4 ... 400 A
40 ... 400 A
10 Hz
100 kHz
180x50x29mm
200 g
Part No.
WATEL-CM07
26
CLAMP METERS
DIGITAL CLAMP‐ON METER ‐ ELMA
FEATURES
• Quick and easy to use clamp‐on meter.
• Auto‐ranging and auto power off.
• Data hold function and overload protection.
• Easy to use single rotary switch for function selection.
• 30mm max jaw opening size.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, carry case and operating
instructions.
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Current measurement range, AC:
Current measurement range, DC:
Min resistance measuring range:
Max resistance measuring range:
Continuity resistor:
Voltage measurement, DC:
Voltage measurement, AC:
Dimensions:
Weight:
CAT III 600V
3 3/4 digit, 3999
400 mV
600 V
400 mV
600 V
40 ... 400 A
40 ... 400 A
400 Ohm
40 MOhm
40 Ohm
Yes
Yes
195x64x30mm
240 g
Part No.
WATEL-TM13E
TEST LEADS SET FOR MULTIMETERS AND CLAMP METERS ‐ WATTMASTER
FEATURES
• Test lead set for Wattmaster WATDMM and WATDCM range of
meters.
Type of accessory:
Testlead
Part No.
WATTLS
27
INSULATION TESTERS
ANALOGUE INSULATION TESTER ‐ WATTMASTER
FEATURES
• Solid state circuitry and automatic circuit discharge.
• Colour coded analogue scale with three megohm voltages.
• Fuse protected.
• Portable and self‐contained insulation tester.
• Battery check feature.
• Live circuit indication.
• Locates intermittent shorts defective electrical connections and
insulation breakdowns due to temperature moisture abrasion and
corrosion.
Indication:
Insulation resistance measuring range:
Accuracy class meter:
Nominal test voltage 250 V:
Nominal test voltage 500 V:
Nominal test voltage 1000 V:
Dimensions:
Weight:
Inclusion:
Analogue
50 ... 200 MOhm
+/-5% of indicated value
Yes
Yes
Yes
170x210x90mm
1000 g
Test leads, power cable, hard case,
batteries & instructions
Part No.
WATIRT2
ANALOGUE INSULATION RESISTANCE TESTER ‐ WATTMASTER
FEATURES
• Expanded insulation and continuity scales for easy reading.
• Live circuit indication.
• IEC 1010‐1.
• Robust style and dual purpose holding case.
• Fuse protected and battery check facility.
• Incorporates front panel ohms zero adjust.
Measuring circuit category:
Indication:
Insulation resistance measuring range:
Accuracy class meter:
Continuity resistor:
Nominal test voltage 250 V:
Nominal test voltage 500 V:
Nominal test voltage 1000 V:
Dimensions:
Weight:
Inclusion:
CAT III 600V
Analogue
100 ... 400 MOhm
+/-5% of indicated value
20 Ohm
Yes
Yes
Yes
170x210x90mm
1000 g
Test leads, fuse, shoulder strap,
batteries & instructions
Part No.
WATAIT2
28
INSULATION TESTERS
ANALOGUE INSULATION TESTER ‐ WATTMASTER
FEATURES
• Solid state circuitry and automatic circuit discharge.
• Colour coded analogue scale with three megohm voltages.
• Fuse protected.
• Battery check feature.
• Portable.
• IEC 364‐6‐61.
• Backlight for dimly lit areas.
Indication:
Insulation resistance measuring range:
Accuracy class meter:
Nominal test voltage 250 V:
Nominal test voltage 500 V:
Nominal test voltage 1000 V:
Dimensions:
Weight:
Inclusion:
Analogue
100 ... 400 MOhm
+/-5% of indicated value
Yes
Yes
Yes
170x115x85mm
1000 g
Test leads, hard case, carry strap,
batteries & instructions
Part No.
WATAIT3
ANALOGUE INSULATION TESTER WITH RECHARGABLE BATTERY ‐ ELMA
FEATURES
• Easy to use insulation tester allows for direct voltage measurement
at the connection.
• Discharges the cable capacity/risidual voltage in seconds.
• Low battery indication and data hold function.
• With built‐in moving coil system and non‐contact voltage indication.
• Easy to use single rotary switch for function selection.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, power cord, 7.
• 2V rechargable battery, carry case and operating instructions.
Measuring circuit category:
NCV indication range:
Voltage type:
Data hold:
Dimensions:
Weight:
CAT III 600V
0 ... 600 V
AC
Yes
156x110x59mm
590 g
Part No.
WATEL-DVM1002
29
INSULATION TESTERS
ANALOGUE INSULATION TESTER WITH 9V BATTERY ‐ ELMA
FEATURES
• Easy to use insulation tester allows for direct voltage measurement
at the connection.
• Discharges the cable capacity/risidual voltage in seconds.
• Low battery indication and data hold function.
• With built‐in moving coil system and non‐contact voltage indication.
• Easy to use single rotary switch for function selection.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, power cord, 9V battery, carry case and
operating instructions.
Measuring circuit category:
NCV indication range:
Voltage type:
Dimensions:
Weight:
CAT III 600V
0 ... 600 V
AC
156x110x59mm
590 g
Part No.
WATEL-DVM1002B
30
INSULATION TESTERS
2‐IN‐1 INSULATION TESTER & MULTIMETER ‐ ELMA
FEATURES
• 2‐in‐1 insulation tester and multimeter.
• Large backlight display allows for all measurements to be viewed at
the same time.
• Low battery indication and data hold function.
• Auto‐ranging and auto power off.
• True RMS.
• Store and recall button allows you to store values and recall them
later.
• With PC connection ‐ can be used for data logging purposes.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, USB cable, software, carry case
and operating instructions.
• Protection class: IP67 (dust‐tight/liquid‐tight)
Measuring circuit category:
Display count:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Lowest resolution, AC current:
Max current measuring range, AC:
Lowest resolution, DC current:
Max current measuring range, DC:
Lowest resolution, resistance:
Max resistance measuring range:
Min frequency measurement:
Max frequency measurement:
Min. capacitance measuring range:
Max capacitance measuring range:
Temperature range:
Continuity resistor:
Min continuity resistor range:
Max continuity resistor range:
Diode test:
Frequency measurement:
Dimensions:
Weight:
CAT III 1000V, CAT IV 600V
10 digit, 40000
400 mV
1000 V
400 mV
1000 V
400 µA
10 A
400 µA
10 A
400 Ohm
40 MOhm
40 Hz
100 MHz
40 nF
40 mF
-50 ... 1000 °C
400 Ohm
35 Ohm
400 Ohm
2.8 V
Yes
220x97x61mm
630 g
Part No.
WATEL-5800
31
INSULATION TESTERS
INSULATION TESTER WITH MULTIMETER ‐ ELMA
FEATURES
• 2‐in‐1 multimeter and insulation tester.
• Handheld digital meter with ruggedised body.
• Low battery indication.
• Auto‐ranging and auto power off.
• Easy to read illuminated display screen.
• Data hold function and overload protection.
• Automatic discharge of capacitive voltage.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, rubber cover, batteries, carry case and
operating instructions.
Measuring circuit category:
Max voltage measuring range, AC:
Max voltage measuring range, DC:
Min resistance measuring range:
Lowest resolution, resistance:
Max resistance measuring range:
Min continuity resistor range:
Max continuity resistor range:
Insulation resistance measuring range:
Data hold:
Dimensions:
Weight:
CAT III 1000V, CAT IV 600V
750 V
1000 V
0 Ohm
40 Ohm
0.0004 MOhm
40 Ohm
400 Ohm
4 ... 4000 MOhm
Yes
200x92x50mm
700 g
Part No.
WATEL-DT5500A
DIGITAL RCD TESTER ‐ ELMA
FEATURES
• Compact RCD tester with multi‐colour graphic display ensures
excellent legibility.
• Built‐in LED light illuminates objects in dim areas.
• Measures trip out time, trip out current and contact voltage.
• Low battery indication and blown fuse indication.
• Auto power off and overload protection.
• With non‐contact voltage indication.
• When not in use instruments body and test tips slide into one
making it more compact.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, pouch, calibration certificate and operating
instructions
Testing device for loop resistance:
Measuring circuit category:
Weight:
Dimensions:
NCV indication range:
Current measurement range, AC:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Fault trip time:
Loop impedance range:
Degree of protection IP:
Yes
CAT III 300V
360 g
260x70x40mm
0 ... 100
10 ... 500 mA
190 V
260 V
500 ms
0 ... 2000 Ohm
IP43
Part No.
WATEL-DRCD
32
VOLTAGE TESTERS
COMPACT VOLTAGE TESTER ‐ THEO BENNING
FEATURES
• Two‐pole voltage tester with visual display.
• Designed to test voltages of 12‐400V AC and 12‐750V DC.
• Voltage tester with load connection.
• Data hold function.
• On the spot exact illumination dimmer test points.
• IEC/EN 61243‐3 DIN VDE 0682‐401.
Measuring circuit category:
Voltage indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Max continuity resistor range:
Degree of protection IP:
Polarity test indication:
Load connection:
Data hold:
Type of test:
Dimensions:
Weight:
Inclusion:
CAT IV 500V
LED
12 V
400 V
12 V
750 V
90 kOhm
IP64
LED
I§ < 200 mA (750V DC)
Yes
2-pole
250x60x25mm
160 g
Battery & instructions
Part No.
WAT050251
EXPERT VOLTAGE TESTER ‐ THEO BENNING
FEATURES
• Two‐pole voltage tester with visual display.
• Designed to test voltages of 12‐400V AC and 12‐750V DC.
• Voltage and continuity tester with load connection phase sequence
indication and switching load.
• Data hold function.
• On the spot exact illumination dimmer test points.
• IEC/EN 61243‐3 DIN VDE 0682‐401.
• Vibrating alarm for safe voltage detection.
Measuring circuit category:
Voltage indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Continuity resistor:
Degree of protection IP:
Polarity test indication:
Phase sequence indication:
Single pole phase test indication:
Load connection:
Data hold:
Type of test:
Dimensions:
Weight:
Inclusion:
CAT IV 500V
LED/LCD
12 V
400 V
12 V
750 V
1.08 MOhm
IP64
LED
LCD
LCD
I§ < 200 mA (750V DC)
Yes
2-pole
250x60x25mm
200 g
Battery & instructions
Part No.
WAT050253
33
VOLTAGE TESTERS
DIGITAL PLUS VOLTAGE TESTER ‐ THEO BENNING
FEATURES
• Two‐pole voltage tester with visual display.
• Designed to test voltages of 5‐500V AC and 1.5‐750V DC.
• Voltage and continuity tester with load connection phase sequence
indication and switching load.
• Data hold function.
• On the spot exact illumination dimmer test points.
• IEC/EN 61243‐3 DIN VDE 0682‐401.
• Vibrating alarm for safe voltage detection.
Measuring circuit category:
Display count:
Voltage indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Max frequency measurement:
Degree of protection IP:
Polarity test indication:
Phase sequence indication:
Single pole phase test indication:
Load connection:
Data hold:
Type of test:
Dimensions:
Weight:
Inclusion:
CAT IV 500V
3 digit
LCD
5V
500 V
1.5 V
750 V
150 Hz
IP64
LCD
LCD
LCD
I§ < 200 mA (750V DC)
Yes
2-pole
250x60x25mm
200 g
Battery & instructions
Part No.
WAT050255
34
VOLTAGE TESTERS
ELECTRICAL VOLTAGE TESTER ‐ WATTMASTER
FEATURES
• Two‐pole voltage tester with visual display.
• Designed to test voltages of 12‐400V AC and 12‐690V DC.
• Voltage and continuity tester with load connection phase sequence
indication low impedance and rotary field indication.
• Handy backlight for dim areas.
• Double moulded plastic housing.
• IEC/EN 61243‐3.
Measuring circuit category:
Voltage indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Continuity resistor limit:
Degree of protection IP:
Polarity test indication:
Phase sequence indication:
Single pole phase test indication:
Load connection:
Type of test:
Dimensions:
Weight:
Inclusion:
CAT III 690V
LED
12 V
400 V
12 V
690 V
< 400 kOhm
IP64
LED
LED
LED
I§ < 0.2A
2-pole
240x78x40mm
237 g
Battery & instructions
Part No.
WATQP-2286
AC/DC VOLTAGE TESTER ‐ ELMA
FEATURES
• Single pole voltage tester with visual display designed to test
voltages of 12‐690V AC/DC.
• Compact, lightweight and easy to use.
• Test pen attachment with 19mm spacing fits directly into wall socket
and allows one‐handed operation.
• Clear indication with LEDs.
• Ergonomic and robust design.
• Probe tip protection and automatic AC/DC detection.
• Complies with IEC 61010‐1 specifications.
• Supplied with batteries and operating instructions.
Measuring circuit category:
Voltage indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Frequency range:
Degree of protection IP:
Polarity test indication:
Dimensions:
Weight:
CAT III 690V
LED
12 V
690 V
12 V
690 V
0 ... 65 Hz
IP54
LED
165x20x16mm
70 g
Part No.
WATEL-1000A
35
VOLTAGE TESTERS
VOLTAGE TESTER 690V AC/DC CAT IV 300V ‐ ELMA
FEATURES
• Single pole voltage tester with visual display designed to test
voltages of 12‐690V AC/DC.
• Compact, lightweight and easy to use.
• Voltage and continuity tester with load connection, phase sequence
(single phase) indication and switching load.
• Data hold function and internal basic load (also for tripping the RCD).
• Ergonomic and robust design.
• Probe tip protection and automatic AC/DC detection.
• Complies with IEC 61010‐1 specifications.
• Supplied with batteries and operating instructions.
Measuring circuit category:
Voltage indication:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Lowest resolution, DC voltage:
Max voltage measuring range, DC:
Continuity resistor range:
Polarity test indication:
Phase sequence indication:
Single pole phase test indication:
Single pole phase indication:
Dimensions:
Weight:
CAT III 600V, CAT IV 300V
LED
12 V
690 V
12 V
690 V
0 ... 200 kOhm
LED
LED
LED
Yes
205x67x27mm
130 g
Part No.
WATEL-1500B
TEST SCREWDRIVERS/VOLTAGE TESTERS ‐ WITTE
FEATURES
• Screwdriver voltage testers.
• With metal clip (except WAT669C) for added convenienve.
• Fully functional voltage tester.
Voltage testing functionality:
Length
115 mm
140 mm
190 mm
153 mm
36
Yes
Voltage measurement range
220 ... 250 V
220 ... 250 V
220 ... 250 V
150 ... 250 V
Part No.
WAT610C
WAT630A
WAT669C
WAT24090
OTHER TESTERS
VS3 TRACKER/TROUBLESHOOTER ‐ SAGAB
FEATURES
• Designed for fault tracing and fuse detection in 230V single phase
applications during maintenace and repair.
• Tests outlet configuration phase connections fuse connections
connection checks and RCD tests.
• Data hold function.
• Auto power off.
• Low battery indication.
• Handy backlight for dim areas.
Part No.
WATVS3
POWER POINT AND EARTH LEAKAGE TESTER ‐ WATTMASTER
FEATURES
• Checks most types of power points for correct wiring and whether
the earth leakage circuit breaker trips from each power point.
• Displays the following faults: no earth/neutral/active connected
active and neutral reversed and active and earth reversed.
• For indoor use only.
• AS/NZS 3100.
• 10mA/15mA/30mA/100mA earth leakage circuit breaker trips
settings.
Indication:
Number of measuring ranges:
Printer connection:
Dimensions:
Inclusion:
Weight:
Current supply:
Testing device for no earth connection:
Testing device for no neutral connection:
Testing device for no active connection:
Testing device for active and neutral reversed:
Testing device for active and earth reversed:
Standards compliance:
Analogue
4
No
65x90x32mm
10A moulded plug &
instructions
250 g
Mains
Yes
Yes
Yes
Yes
Yes
AS/NSZ 3100
Part No.
WATQP-2000
37
OTHER TESTERS
CABLE TRACER ‐ WATTMASTER
FEATURES
• Instrument to identify and trace cables.
• Amplifier probe and tone generator kitA 3‐position toggle switch
controls the modes of operation.
• A tone selector switch is provided for choosing either single solid
tone or dual alternating tone.
• Volume control for increased sensitivity and adjustable to suit work
environment.
• Works with any tone generator to identify wires.
• Recessed ON/OFF button prevents battery drain.
Part No.
WATFSET
CIRCUIT BREAKER IDENTIFIER & FAULT FINDER ‐ WATTMASTER
FEATURES
• Circuit breaker identifier and earth fault finder
Circuit breaker identification:
Earth fault identification:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Transmitter/receiver frequency:
Type of indication:
Auto off timing:
On/off button:
Analogue bargraph display:
Low battery indication:
Transmitter dimensions:
Receiver dimensions:
Transmitter weight:
Receiver weight:
Yes
Yes
110 V
240 V
10 kHz
LED/acoustic
Approx 1 minute
Yes
Yes
Yes
60x50x30mm
200x50x40mm
134 g
112 g
Part No.
WATCBI-T188
38
OTHER TESTERS
CIRCUIT BREAKER IDENTIFIER 220‐240VAC ‐ WATTMASTER
FEATURES
• Ideal tool for both automated office environments where disruption
of power is not practical as well as in residential applications.
• Quickly identifies and locates 220‐240VAC circuit breakers and fuses.
• Audible tone generated when matching breaker is located.
• It is an easy way to identify location of circuit breaker on the circuit
breaker panel box which is connected to a specific outlet.
Part No.
WATCBI-T191
LUX & FC LIGHT METER ‐ WATTMASTER
FEATURES
• Accurately displays light level in terms of footcandles (fc) or lux over
wide ranges.
• Low battery indication.
• Data hold function and auto power off.
• Pocket sized.
• Lightweight.
• Includes an integrated stand.
Indication:
Measuring range:
Display count:
Dimensions:
Data hold:
Low battery indication:
Inclusion:
Weight:
Blueway energy efficient:
Digital
200 ... 50000 lx
3 1/2 digit, 1999
188x64x25mm
Yes
Yes
Carry case & instructions
160 g
Energy saving product
Part No.
WATQM-1587
39
OTHER TESTERS
LIGHT METER 200LUX ‐ ELMA
FEATURES
• Ideal for measuring a wide range of light sources eg emergency
lighting and outdoor measurement in sunshine.
• Large display screen.
• Data hold and overload protection.
• Compact, lightweight and easy to handle.
• Auto power off.
• High accuracy and rapid response.
• Supplied with sensor, batteries, carry case and operating
instructions.
Measuring range:
Display count:
Dimensions:
Data hold:
Weight:
40 ... 400000 lx
3 3/4 digit, 3999
135x60x27mm
Yes
250 g
Part No.
WATEL-1335
INFRARED THERMO W/DOUBLE LASER 600DEG ‐ ELMA
FEATURES
• Store and recall button allows you to store values and recall them
later.
• With PC connection‐ can be used for data logging purposes.
• Complies with IEC 61010‐1 specifications.
• Supplied with test leads, batteries, USB cable, software, carry case
and operating instructions.
• Protection class: IP67 (dust‐tight/liquid‐tight).
• Note: not recommended for measuring shiny or polished surfaces,
stainless steel, aluminium etc.
Measuring range:
Measurement of differential temperature:
Display count:
-50 ... 600 °C
Yes
3 1/2 digit, 1999
Part No.
WATEL-610A
40
OTHER TESTERS
INFRARED THERMO W/DOUBLE LASER 1000DEG ‐ ELMA
FEATURES
• Rapid detection and dual laser sighting ie two infrared sensors.
• Precise non‐contact measurements ideal for applications such as
refrigerator/freezer testing, moving machine parts and electrical
components, safety and fire inspections etc.
• Celsius/Farenheit selection button.
• Backlight LCD display.
• Handy and convenient ergonomic pistol handle grip design.
• Supplied with battery, carry case and operating instructions.
Measuring range:
Display count:
Weight:
-50 ... 1000 °C
3 1/2 digit, 1999
160 g
Part No.
WATEL-611B
WIRELESS ENERGY CONTROL MONITOR ‐ WATTMASTER
FEATURES
• Measures electricity consumption of single or several appliances
over days weeks months and years.
• Quick and easy to install.
• Displays current time and temperature.
• Allows you to monitor control and save electricity.
• Spare sensor available: WATMS‐6156.
Type of accessory:
Monitor kit
Part No.
WATMS-6155
41
OTHER TESTERS
TACHOMETER PHOTO/CONTACT ‐ ELMA
FEATURES
• Combination photo and contact tachometer measures revolutions
(via light and reflection), mechanical RPM (via measuring tip) and
speed (via measuring wheel).
• Memory button for remembering highest, lowest and last values.
• LCD display screen.
• Auto‐ranging and data hold function.
• Supplied with reflective tape, test leads, carry case and operating
instructions
Display count:
Photo contact RPM:
Contact area RPM:
Measuring range:
Dimensions:
Weight:
5 digit, 10mm
5 ... 99999
0.5 ... 19999
0.5 ... 1999.99 1/min
215x65x38mm
300 g
Part No.
WATEL-DT2236
VOLT STICKS
VOLT STICK ‐ SAGAB
FEATURES
• Tests for the presence of AC voltage in cables wall sockets and
switches without metal contact.
• Pocket sized non‐contact voltage sensor with light and sound
indication.
• Beeping sound indicates live wire.
• Fully insulated body and safety hand guard.
• Still illuminates at low battery charge.
Measuring circuit category:
Contact less voltage detection:
Voltage indication:
Voltage measurement range:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Sensitivity specification:
Material:
Current supply:
Dimensions:
Weight:
CAT III 1000V AC
Yes
Glow lamp
230 ... 1000 V
230 V
1000 V
Indicates within 4mm of wire carrying
230V AC
Pa6, PP-COP
Battery
146x18mm
40 g
Part No.
WATVS
42
VOLT STICKS
MAGNET FIELD INDICATOR ‐ SAGAB
FEATURES
• Easy to use non‐metallic sensor test for the presence of magnetic
fields.
• Responds to all kinds of magnetic fields such as AC DC and
permanent magnets.
• For testing solenoid vaves in pneumatic and hydraulic control
equipment.
• Tip glows red when magnet field is detected.
• Also tests relays with coils and electrically controlled solenoid valves.
• Test magnet included in cap.
Measuring circuit category:
Voltage indication:
Magnetic field indication:
Sensitivity specification:
Indication of direction of field rotation:
Material:
Current supply:
Dimensions:
Weight:
Inclusion:
CAT III 1000V AC
Glow lamp
Glow lamp
300 gauss (0.3mT)
Yes
Pa6, PP-COP
Battery
152x17mm
40 g
Test magnet
Part No.
WATMT702
VOLT STICK FLAT TIP ‐ SAGAB
FEATURES
• Tests for the presence of AC voltage in cables wall sockets and
switches without metal contact.
• Pocket sized non‐contact voltage sensor with light and sound
indication.
• Flat tip fits into standard power point.
• Beeping sound indicates live wire.
• Fully insulated body and safety hand guard.
• Still illuminates at low battery charge.
Measuring circuit category:
Contact less voltage detection:
Voltage indication:
Voltage measurement range:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Sensitivity specification:
Material:
Current supply:
Dimensions:
Weight:
CAT III 1000V AC
Yes
Glow lamp
230 ... 1000 V
230 V
1000 V
Indicates within 4mm of wire carrying
230V AC
Pa6, PP-COP
Battery
146x18mm
40 g
Part No.
WATVSFT
43
VOLT STICKS
VOLT STICK PRO ‐ SAGAB
FEATURES
• Tests for the presence of AC voltage in cables wall sockets and
switches without metal contact.
• Unique fork tip glows red when voltage is detected eliminating the
risk of false indication.
• Differentiates between live and neutral in a 1‐to‐3 phase installation.
• arthed outlets with anti‐tamper can be check with the supplied
adaptor found in cap.
• Used to check cicuit breaker functionality and locate breaks in
insulated cables.
• Used to detect live cables in junction boxes and equipment cabinets.
Measuring circuit category:
Contact less voltage detection:
Voltage indication:
Voltage measurement range:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Sensitivity specification:
Material:
Current supply:
Dimensions:
Weight:
CAT III 1000V AC
Yes
Glow lamp
12 ... 600 V
12 V
600 V
Indicates from 12V AC in the forked tip
Pa6, PP-COP
Battery
146x22mm
40 g
Part No.
WATVSPRO
VOLT STICK PRO 230 ‐ SAGAB
FEATURES
• Unique fork tip gives unsurpassed sensitivity and reduces the risk of
false identification.
• Live cables can be easily detected in equipment enclosures and fuse
boxes.
• Extremely safe when measuring in junction boxes.
• Tips glows red when voltage is detected.
• Adaptor for measuring larger objects is included.
• Fully insulated for safe use.
Measuring circuit category:
Contact less voltage detection:
Voltage indication:
Voltage measurement range:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Sensitivity specification:
Material:
Current supply:
Dimensions:
Weight:
CAT III 1000V AC
Yes
Glow lamp
230 ... 1000 V
230 V
1000 V
Indicates within 4mm of wire carrying
230V AC
Pa6, PP-COP
Battery
151x18mm
50 g
Part No.
WATVSP230
44
VOLT STICKS
INTRINSICALLY SAFE VOLT STICK ‐ SAGAB
FEATURES
• Intrinsically safe volt stick tests for the presence of AC voltage in
cables wall sockets and switches without metal contact.
• Pocket sized non‐contact voltage sensor with light indication.
• Locates breaks in cables and detects blown fuses.
• Distinguishes between live and neutral wires in both single phase
and three phase supply.
• Safety hand guard prevents contact with dangerous cable.
• IEC Ex NEM 07.0001.
Measuring circuit category:
Contact less voltage detection:
Voltage indication:
Voltage measurement range:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Sensitivity specification:
Material:
Current supply:
Dimensions:
Weight:
CAT III 100V
Yes
Glow lamp
230 ... 1000 V
230 V
1000 V
Indicates within 4mm of wire carrying
230V AC
Pa6, PP-COP
Battery
151x18mm
40 g
Part No.
WATVS660-642
50V VOLT STICK ‐ SAGAB
FEATURES
• Tests for the presence of AC voltage in cables wall sockets and
switches without metal contact.
• Pocket sized non‐contact voltage sensor with light indication.
• Tip glows red when voltage is detected.
• Fully insulated for safe use.
• Safety hand guard prevents contact with dangerous cable.
• IEC Ex NEM 07.0001.
Measuring circuit category:
Contact less voltage detection:
Voltage indication:
Voltage measurement range:
Lowest resolution, AC voltage:
Max voltage measuring range, AC:
Sensitivity specification:
Material:
Current supply:
Dimensions:
Weight:
CAT III 1000V AC
Yes
Glow lamp
50 ... 1000 V
50 V
1000 V
Indicates within 4mm of wire carrying
50V AC
Pa6, PP-COP
Battery
145x18mm
35 g
Part No.
WATVS-LV50
45
INDEX BY PART NUMBER
Part No.
WAT044073
WAT044073
WAT050251
WAT050253
WAT050255
WAT115A
WAT24090
WAT610C
WAT630A
WAT669C
WATAIT2
WATAIT3
WATCBI-T188
WATCBI-T191
WATDCM1046
WATDCM1065
WATDCM2606
WATDMM9001
WATDMM904
WATEL-1000A
WATEL-126
WATEL-1335
46
Page
9
19
33
33
34
5
36
36
36
36
28
29
38
39
17
18
18
8
6
35
20
40
Part No.
WATEL-1500B
WATEL-155
WATEL-25
WATEL-2500
WATEL-3036
WATEL-3038
WATEL-5800
WATEL-5800
WATEL-610A
WATEL-611B
WATEL-805
WATEL-807
WATEL-9015
WATEL-BM117
WATEL-BM257
WATEL-BM829
WATEL-CM01
WATEL-CM07
WATEL-DRCD
WATEL-DT2236
WATEL-DT5500A
WATEL-DT5500A
Page
36
21
7
21
22
23
31
16
40
41
10
11
24
25
12
13
26
26
32
42
32
14
Part No.
WATEL-DVM1002
WATEL-DVM1002B
WATEL-TM13E
WATFSET
WATIRT2
WATMS-6155
WATMT702
WATQM-1020
WATQM-1500
WATQM-1587
WATQP-2000
WATQP-2286
WATTLS
WATTLS
WATVS
WATVS3
WATVS660-642
WATVSFT
WATVS-LV50
WATVSP230
WATVSPRO
Page
29
30
27
38
28
41
43
15
14
39
37
35
27
17
42
37
45
43
45
44
44
Measurement_cover_Final.pdf 1 14/11/2012 12:41:06 PM
C
M
Y
CM
MY
CY
CMY
K