All construction shall be in compliance with the 2010 Florida Building Code, Building,
Residential, Existing Building, Plumbing, and Mechanical with 2009 Supplements. The 2008
National Electrical Code. All Lee County Ordinances. And all current Florida State Statues, to
include # 553.844 and #553.885.
Contractors shall be responsible for all dimensions, locations, and quantities.
All color samples shall be submitted and approved by this office prior to work commencing.
Note: No deviation from this specification will be permitted without written and signed
authorization by Lee County Department of Human Services.
Contractors must obtain ALL NECESSARY PERMITS and all necessary documents from Federal,
State and Local governmental agencies prior to commencement of any work, and
furnish copies of permits to Lee County Department of Human Services prior to commencement of any
work. Permits will cover all work to be completed under this schedule of work.
SCHEDULE OF WORK
DESCRIPTION OF ELECTRICAL
All work shall comply with the 2008 National Electrical Code and Florida State Statue
553.885
1. Service and Distribution: Furnish all new electrical lines from new submersible
pump at the bottom of the well to the well head and from well head junction to the house as
required by code. Check balance of existing circuits that service the submersible well pump and
all equipment on the side of the house. Check to ensure proper size amp electrical service and
repair as needed. All 220V receptacles for well equipment will be amped per mfg.
specifications, circuits complete with proper ground. All work will comply with the 2008
National Electrical Code and Life Safety Code for an existing dwelling and be completed in a
workmanlike manner.
$
S:\HSNG\Photographs-Specs\FY15\Anderson, Linda\REHAB SPECS 2010 CODE.doc
Effective 4/30/15
1
DESCRIPTION OF PLUMBING
All work shall comply with the 2010 Florida Plumbing Code
1. Electric Water Heater: Provide and install a new glass lined, quick recovery, electric
water heater. Heater shall be equipped with a high limit safety cut off, pan, and pressure relief
valve piped to the outside. Heater shall be 220 volts, double element, 4500 watts with minimum
of five- (5) year guarantee. Size shall be a 40 gallon capacity to match existing unit. (A.O.
Smith, State, Rudd, Rheem) or equal style. Installation shall comply with the 2010 Florida
Building Code Standards and be completed in a workmanlike manner. Location as per existing.
Reliance brand shall not be acceptable.
$
2. New Well and Pump: Furnish a new well. Provide all labor and material necessary
for the installations of the new well and submersible pump in a new location on site. Location of
new well must meet all current codes. Well shall be a 4" P.V.C., actual depth of the existing well
will be as required given the location, cement grout and all other items necessary for a complete
system. Well shall provide a minimum flow of 20 gallons per minute. Pump: Provide and install
a 1 HP "J" series signature 2000 pump or equal. Cost shall include drop pipe, submersible cable,
well fill, pressure relief valve, control check, pressure gauge, pump start relay, etc. Provide
balance of work as necessary for a complete system. Abandon the old well site as per code,
costs will be included with this item.
$
3. Water Pump/Well Equipment: Provide all new well equipment at the side of the house.
When complete equipment shall be in a user ready state of operation to include all pumps,
salt tank, pressure tanks, aerator tank, gauges, pump relay switches and central water
filtration units for Iron/Hydrogen Sulfide.
$
DESCRIPTION OF MECHANICALS
All work shall comply with the 2010 Florida Mechanical Code
1. Central Heat and Air Ducts: Remove existing supply and return grills. All existing
duct work shall be inspected for leaks and shall be repaired where required. Existing ceiling or
wall boxes shall be completely enclosed in mastic inside and out. Use of mastic and/or UL-181
tape is required. Existing duct work shall be cleaned, disinfected, and dried. Make repairs to
plenum box in garage as needed. All work shall be completed in a workmanlike manner.
$
DESCRIPTION OF PERMITS AND MISCELLANEOUS
1. Misc.: Provide all temporary services required to complete project, including
temporary electric pole, porta-a-let, and/or temporary water if necessary.
$
S:\HSNG\Photographs-Specs\FY15\Anderson, Linda\REHAB SPECS 2010 CODE.doc
Effective 4/30/15
2
2. Clean Up: Leave entire interior and exterior premises clean and free of debris. No
debris shall be burned on site. All surplus materials to be removed shall become the property of
the contractor unless otherwise stipulated. Clean up will be completed in a timely and
workmanlike manner, including the removal of all equipment.
$
1. 3. Permits: Contractor must submit the entire work schedule to building department to
ensure all proper permits are obtained. Obtain all necessary permits and all necessary documents
(Con-currency Requirements, etc.) from Federal, State and Local governmental agencies prior to
commencement of any work. Furnish copies of permits and all necessary documents to Lee
County Department of Human Services prior to commencement of any work. Permits will cover
all work completed under schedule of work for general, electrical, plumbing, HVAC, and
roofing. All fees shall be paid by contractor for permits required by application. All inspection
scheduling shall be the responsibility of the general contractor.
Submit Lee County permit package to Tracey Berry or Karen Myers. The plan reviewer if
necessary shall be Linda Ramsey.
$
TOTAL BASE BID
$
Authorized Contractor's Signature:
Contractors name:_________________________________________________.
Company name:__________________________________________________.
Contractors Address:
.
S:\HSNG\Photographs-Specs\FY15\Anderson, Linda\REHAB SPECS 2010 CODE.doc
S:\HSNG\Photographs-Specs\FY15\Anderson, Linda\REHAB SPECS 2010 CODE.doc
Effective 4/30/15
3
Download