NEXION Commercial Lighting Controls

advertisement
NEXION Commercial
Lighting Controls
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Ceiling Mount Ultrasonic
Occupancy Sensor
Ultrasonic
10-30 V/DC
Commercial Specification Grade Ultrasonic Occupancy Sensor
FEATURES
• California Title 24 compliant.
• Ultrasonic activation is ideal for spaces
needing increased sensitivity to minor motion
detection.
• Adjustable sensitivity and time delay.
• Time delay adjustable from 15 seconds to
30 minutes.
• Multiple frequencies enable separate
controls of adjacent areas.
• Teflon-insulated pigtails fire-rated for ceiling
plenums.
• Complete no-gap coverage; NEMA WD7
Guide robotic method utilized to verify
coverage patterns.
• One hole mounting for fast installation.
• Paintable off-white ABS molded housing.
• Manual override switch turns lights on in case
of sensor malfunction.
6.00"
(152mm)
2.31"
(59mm)
Wire Leads – Ceiling Mount
Depth:
1.62"
(41mm)
AHOEC-U-2000
Frequency
Coverage Area
Description
Catalog No.
40 kHz
Up to 500 sq. ft.
(46.2 sq. m)
180º One Way Ultrasonic
Occupancy Sensor
32 kHz
500-1000 sq. ft.
(46.2-92.2 sq. m)
180º One Way Ultrasonic
Occupancy Sensor
32 kHz
1000-2000 sq. ft.
(92.2-185.8 sq. m)
360º Two Way Ultrasonic
Occupancy Sensor
32 kHz
50 linear ft.
(15.2 m)
180º One Way Ultrasonic
Hallway Occ. Sensor
32 kHz
100 linear ft.
(30.5 m)
360º Two Way Ultrasonic
Hallway Occ. Sensor
I AHOEC-U-0501
•
I AHOEC-U-1001
•
I AHOEC-U-2000
•
I AHOEC-U-0051-H
I AHOEC-U-0100-H
Coverage Areas
AHOEC-U-0501
Series
AHOEC-U-1001
Series
AHOEC-U-2000
Series
No partitions
Up to 500 sq. ft.
Max. mounting
height: 12 ft.
No partitions
Up to 1000 sq. ft.
Max. mounting
height: 12 ft.
No partitions
Up to 2000 sq. ft.
Max. mounting
height: 12 ft.
AHOEC-U-0501
Series
AHOEC-U-1001
Series
AHOEC-U-2000
Series
49-71” partition ht.
Up to 350 sq. ft.
Max. mounting
height: 12 ft.
49-71” partition ht.
Up to 350 sq. ft.
Max. mounting
height: 12 ft.
49-71” partition ht.
Up to 700 sq. ft.
Max. mounting
height: 12 ft.
AHOEC-U-0100-H Series
Up to 75 linear ft.
Max. mounting height: 12 ft.
TESTING & CODE COMPLIANCE
MATERIAL CHARACTERISTICS
• Listed to UL 508
• California Title 24 Energy Code compliant
• Environmental: Flammability meets UL94
requirements; V0 rated
• Temperature Rating: 15ºC to 26ºC (60ºF to 80ºF)
NAFTA Compliant
www.cooperwiringdevices.com
Occupancy Sensor
Specification & Performance Data
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Ceiling Mount Ultrasonic
Occupancy Sensor
Ultrasonic
10-30 V/DC
Application
The Standard ceiling sensors offer a wide range of basic ultrasonic occupancy sensors. They can be used to control lighting or
small fans in rooms and corridors of various shapes and sizes. These models activate a switchpack to turn the loads on and off.
Ultrasonic sensors are ideal in spaces where you need increased sensitivity to minor motion (like a hand waving) in larger spaces
(>500 sq. ft.). Ceiling sensors are typically used in large or small spaces where wall switch sensor can not be used due to switch
location, room orientation or furniture placement. These sensors are ideal for offices, conference rooms, storage rooms, large open
areas, partitioned areas, corridors and hallways.
Device Type
Ceiling Mount Occupancy Sensor,
AHOEC-U Series
Wiring Type
Pre-stripped teflon-insulated wire leads
One Switchpack, Multiple Sensors
• Listed to UL 508
Testing & Code Compliance
• California Title 24 Energy Code
compliant
Temperature Rating
15ºC to 26ºC (60°F to 80°F)
Humidity Rating
Relative humidity less than 90%,
non-condensing
Operating Areas
For indoor ceiling use only
10-30 VDC from switchpack
Power Requirements
Output
Open collector output to switch up to 10
switchpacks
Available Frequencies
32 & 40 kHz
Detection Technology
Ultrasonic
Mounting
NEMA double-gang box (use #AHACMP)
or mounting post & washer
LED Indicating Lamp
Green (AHOEC-U-0501) or red (all other
sensors)
Time Delay
From 15 sec. to 30 min.
Coverage
Up to 1000 sq ft. in 180° field of view (one
way model); up to 2000 ft. in 360º field of
view (two way model); 100 linear ft
(AHOEC-U-0100-H only)
Potentiometer
Accessed through side openings
Housing
Medium-impact injection molded ABS
resin housing, paintable
Specifications:
Materials
Specifications:
Operation
Specifications:
Environmental
Meets UL 94 requirements; V0 rated
Flammability
Specifications:
Electrical
5-year limited warranty
Specifications:
Mechanical
Warranty
Multiple Switchpacks, One Sensor
Maximum Current Per Sensor 25mA
Specifications subject to
change without notice.
www.cooperwiringdevices.com
2-CLCCUSSPSH-0211
Download