)NDIVIDUAL3ILICON3URGE 3UPPRESSIONFOR4O6$#AND ,OW6OLTAGE6!#!PPLICATIONS Todayʼs technology involves sensitive electronic equipment which you depend upon for systems reliability. Your valuable electronic systems will experience unpredictable and potentially destructive power quality conditions such as lightning and transients which cost your business maintenance time, equipment replacement and customer dissatisfaction. Our I2R ICP Series features our proprietary silicon avalanche suppressor diode (SASD) technology for effective safeguarding and maximized performance of your systems. In addition, it provides remote status monitoring and plug-in modules. Your success demands a superior protection solution provided by Transtector Systems. !PPLICATIONS • Telecom Power Systems • Communications Hubs, Nodes • Digital Loop Carries • Cabinets/Load Centers • Din Rail Mounts • Solar & Turbine )2)#03ERIES$# )NDIVIDUAL3ILICON3URGE3UPPRESSION &OR4O6$#AND,OW6OLTAGE6!#!PPLICATIONS • 100% silicon suppression • Plug-in suppression modules with status indicators • Designed to standard 35mm DIN Rail profile and compact footprint Nominal Service 12V 24V 48V Protection Levels* 36V 58V 90V Current Ratings 2kA 2kA 2kA Operating Temperature -30 º C to +65 º C Response Time (Max.) <5 Nanoseconds Part Number 1101-624 • Mountable without DIN Rail * • Remote status monitoring capability DC + ������ - Figure 1 I2R ICP Common 3. Wiring the I2R ICP Series: Unplug Suppressor Module from base. Install 4-14 AWG into base per Figure 1 or 2 keeping leads as short as possible. Typical Application 4. Insert Suppressor Module into Base Unit. 5. Optional Wiring for Remote Status Indication (see Figure 4)* 5.1 Use test plug included in packaging.* 5.2 Wire with respect to opposite rail as indicated by voltage potential in Figure 4. 5.3 Maximum continuous current for remote status not to exceed .5A. Remote Lamp Indicator On = Protected Voltage Potential Output Plug Included REMOTE 2. Mounting the I2R ICP Series 2.1 35 mm DIN Rail Mount (see Figure 3) 2.2 Screw Mount (see Figure 4) Figure 2 Multiple Unit Wiring Diagrams Remote Status Indication Plug I2R ICP Series - For IEEE Locations A and B Per C62.41-1991 1. Warning! Disconnect power upstream from the device when wiring to avoid potential shock hazard. Unit must be installed within an enclosure. It is recommended that a 15 or 20A current limiting fuse be installed in series with each I2R ICP. Example Bussmann KTK 15 or KTK 20. Low Voltage VAC ������ Figure 1 Base Unit 2.6”H X 1.09”W X 2.64”L 6.6 cm X 2.8 cm X 6.7 cm Installation I2R ICP L Dimensions Five (5) year unconditional warranty Ten (10) year manufacturer warranty Single Phase Wiring Diagrams MOUNTING OPTION 1101-626 Voltage protection level determined at 6kV 500A. Warranty • UL and CSA approved and designed to meet IEC specifications 1101-625 I 2R ICP Series - DC Configurations Features 6. Turn power on. LED illumination indicates power is supplied and suppression is enabled. WARNING!!! REMOTE STATUS CONTACT IS ENERGIZED. LIVE ELECTRICAL POWER EVEN WITHOUT LED ILLUMINATION. STATUS Figure 4 Suppressor Module 208.772.8515 800.882.9110 FAX 208.762.6133 10701 N. Airport Road, Hayden, ID 83835 www.transtector.com sales@transtector.com An ISO 9001:2000 and 14001 Certified Company 1452-011 Rev.B