Effective 07-27-2011* PRODUCT ORDERING GUIDE For UL 325 Listed Commercial and Industrial Door Operators Built After August 29, 2010 *Subject to change. Please contact Miller Edge or your operator manufacturer for current compliance information Effective 07-27-2011* PRODUCT ORDERING GUIDE This Product Ordering Guide was developed to aid you in selecting the proper products for use with UL Listed Commercial and Industrial door operators built after August 29, 2010. We have included product recommendations for both monitored and ancillary devices for most of the leading operator manufacturers. The chart below outlines the Monitored Sensing Edge Designator and its properties. It is important to understand the formula for creating a Miller Edge Part number. If you have any questions, feel free to contact your local Miller Edge Sales Representative. (Eastern Time - 1-800-220-3343 ) (Mountain Time - 1-800-887-3343) Part Number Example: ME123-2U-12-T1 Sensing Edge Model Style Designator Sensing Edge Model Number Wire Type and Outlet Location Length of Sensing Edge Monitored Sensing Edge Designator Designator Description Operator Manufacturer T1 8.2K Ohm Resistor Typically European Use Green T2 10K Ohm Resistor Cornell / US Gear LiftMaster / Chamberlain Linear Manaras Micanan Raynor VE Power Door Cookson Lawrence Blue T3 Diode Capacitor Overhead Door (Only) Red T4 Capacitor Linear (Transmitter) White T5 6.8K Ohm Resistor Custom Applications Orange T6 270K Ohm Resistor LiftMaster CPS Board Violet LiftMaster None 2 Wire Edge Designator ex. ME123-2U-12-T2 4 Wire Edge Designator ex. ME123-4U-12 N/A Outlet Wire Color Code *Subject to change. Please contact Miller Edge or your operator manufacturer for current compliance information 1 Miller Edge Ordering Guide Effective 07-27-2011* CORNELL MG/SG / US GEAR Operator Manufacturer Monitored Device Cornell / US Gear SENSING EDGE NO SIGNATURE MODULE REQUIRED Use any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a T2* Designator Example: ME110-2R-12-T2 Ancillary Device Any 2 Wire Normally Open (N.O.) - ME, MT, MU, CPT, Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye or PHOTO EYE Operator Provided Monitored Photo Eye Monitored Device Wiring Diagram Operator EM105EHL 2 Wired Monitored Sensing Edge Main Control Board BLACK E6 E5 ME, MT, MU, CPT Edges with T2 (10KΩ) WHITE Sensing Module ELR Make sure the sensing module ELR is connected to the main control at “CN8-Sensing Device” * T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire *Subject to change. Please contact Miller Edge or your operator manufacturer for current compliance information 2 Miller Edge Ordering Guide Effective 07-27-2011* LIFTMASTER / CHAMBERLAIN Operator Manufacturer Monitored Device Ancillary Device SENSING EDGE USE CPS-MEI Module from Chamberlain with any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a T2* Designator Example: ME123-2U-12-T2 or PHOTO EYE Operator Provided Monitored Photo Eye Liftmaster/ Chamberlain Any 2 Wire Normally Open (N.O.) - ME, MT, MU, CPT, Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye Monitored Device Wiring Diagrams Logic 4 Operator 2 WIRE MONITORED SENSING EDGE COMMON BLACK RED RED WHITE LMEP1 CPT223/ME/MT/MU CPS-MEI Medium Duty Logic Operator 2 WIRE MONITORED SENSING EDGE LMEP1 LMEP2 BLACK RED RED WHITE CPT223/ME/MT/MU CPS-MEI CPS-MEI Fire Door Operator 1 2 2 WIRE MONITORED SENSING EDGE BLACK RED RED WHITE CPT223/ME/MT/MU CPS-MEI CPS-MEI * T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire *Subject to change. Please contact Miller Edge or your operator manufacturer for current compliance information 3 Miller Edge Ordering Guide Effective 07-27-2011* LINEAR Operator Manufacturer Monitored Device Ancillary Device Linear SENSING EDGE Any 2 Wire Normally Open (N.O.) - ME, MT, MU, CPT, Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye USE SM-102 with any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a T2* Designator Example: ME123-2U-12-T2 or PHOTO EYE Operator Provided Monitored Photo Eye Monitored Device Wiring Diagram 2 Wired Monitored Sensing Edge Linear M50JE5011S Operator PHOTO COM RED BLACK SM-102 RED ME, MT, MU, CPT Edges with T2 (10KΩ) WHITE * T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire *Subject to change. Please contact Miller Edge or your operator manufacturer for current compliance information 4 Miller Edge Ordering Guide Effective 07-11-2011 MANARAS - OPERA Operator Manufacturer Manaras Monitored Device Ancillary Device SENSING EDGE Any 2 Wire Normally Open (N.O.) - ME, MT, MU, CPT, Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye USE SM-102 with any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a T2* Designator Example: ME123-2U-12-T2 or PHOTO EYE Operator Provided Monitored Photo Eye Monitored Device Wiring Diagram 2 Wired Monitored Sensing Edge * T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire *Subject to change. Please contact Miller Edge or your operator manufacturer for current compliance information 5 Miller Edge Ordering Guide Effective 07-27-2011* MICANAN Operator Manufacturer Monitored Device SENSING EDGE Micanan USE SM-102 with any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a T2* Designator Example: ME123-2U-12-T2 Ancillary Device Any 2 Wire Normally Open (N.O.) - ME, MT, MU, CPT, Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye or PHOTO EYE Operator Provided Monitored Photo Eye Monitored Device Wiring Diagram 2 Wired Monitored Sensing Edge Micanan PRO-H Operator BEAM 1 BEAM 2 EDGE 1 EDGE 2 RED BLACK SM-102 RED ME, MT, MU, CPT Edges with T2 (10KΩ) WHITE Factory Installed * T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire *Subject to change. Please contact Miller Edge or your operator manufacturer for current compliance information 6 Miller Edge Ordering Guide Effective 07-27-2011* OVERHEAD DOOR Operator Manufacturer Overhead Door Monitored Device SENSING EDGE USE Miller Edge P/N SM-101 or Overhead Door P/N OPAKMEIX.S with any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a T3**Designator or PHOTO EYE Ancillary Device Any 2 Wire Normally Open (N.O.) - ME, MT, MU, CPT, Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye Operator Provided Monitored Photo Eye Monitored Device Wiring Diagram Overhead Door OPRMX/RSX Set “ODC_STB=ON” in operator 2 Wired Monitored Sensing Edge Operator ODC STB ODC STB RED RED SM-101 OPAKMEIX.S BLACK ME, MT, MU, CPT Edges with T3 WHITE ** T3 - an embedded diode capacitor with a Red Band on the edge outlet wire *Subject to change. Please contact Miller Edge or your operator manufacturer for current compliance information 7 Miller Edge Ordering Guide Effective 07-27-2011* RAYNOR Operator Manufacturer Monitored Device SENSING EDGE Raynor USE SM-102 with any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a T2* Designator Example: ME123-2U-12-T2 Ancillary Device Any 2 Wire Normally Open (N.O.) - ME, MT, MU, CPT, Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye or PHOTO EYE Operator Provided Monitored Photo Eye Monitored Device Wiring Diagrams 2 Wired Monitored Sensing Edge Raynor Operator PHOTO COM RED BLACK SM-102 RED ME, MT, MU, CPT Edges with T2 (10KΩ) WHITE * T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire *Subject to change. Please contact Miller Edge or your operator manufacturer for current compliance information 8 Miller Edge Ordering Guide Effective 07-27-2011* VE POWER DOOR Operator Manufacturer Monitored Device SENSING EDGE VE Power Door USE SM-102 with any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a T2* Designator Example: ME123-2U-12-T2 or PHOTO EYE Operator Provided Monitored Photo Eye Ancillary Device Any 2 Wire Normally Open (N.O.) - ME, MT, MU, CPT, Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye COOKSON Operator Manufacturer Monitored Device SENSING EDGE NO SIGNATURE MODULE REQUIRED Use any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a T2* Designator Example: ME110-2R-12-T2 or PHOTO EYE Operator Provided Monitored Photo Eye Cookson Ancillary Device Any 2 Wire Normally Open (N.O.) - ME, MT, MU, CPT, Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye LAWRENCE Operator Manufacturer Monitored Device Ancillary Device SENSING EDGE Lawrence NO SIGNATURE MODULE REQUIRED Use any 2 wire monitored Miller Edge model beginning with ME, MT, MU, CPT with a T2* Designator Example: ME110-2R-12-T2 or PHOTO EYE Operator Provided Monitored Photo Eye Any 2 Wire Normally Open (N.O.) - ME, MT, MU, CPT, Air- Wave, Pneumatic, Invisi-Guard, Light Curtain, Patriot, or Photo Eye * T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire *Subject to change. Please contact Miller Edge or your operator manufacturer for current compliance information 9