UL325-2010 Commercial Operator Compatibility

advertisement
Effective 07-27-2011*
PRODUCT
ORDERING GUIDE
For UL 325 Listed
Commercial and Industrial
Door Operators
Built After
August 29, 2010
*Subject to change.
Please contact Miller Edge or your operator manufacturer for current compliance information
Effective 07-27-2011*
PRODUCT ORDERING GUIDE
This Product Ordering Guide was developed to aid you in selecting the proper products for use with
UL Listed Commercial and Industrial door operators built after August 29, 2010. We have included
product recommendations for both monitored and ancillary devices for most of the leading operator
manufacturers. The chart below outlines the Monitored Sensing Edge Designator and its properties.
It is important to understand the formula for creating a Miller Edge Part number. If you have any
questions, feel free to contact your local Miller Edge Sales Representative.
(Eastern Time - 1-800-220-3343 ) (Mountain Time - 1-800-887-3343)
Part Number Example:
ME123-2U-12-T1
Sensing Edge Model Style
Designator
Sensing Edge Model Number
Wire Type and Outlet Location
Length of Sensing Edge
Monitored Sensing Edge Designator
Designator Description
Operator Manufacturer
T1
8.2K Ohm Resistor
Typically European Use
Green
T2
10K Ohm Resistor
Cornell / US Gear
LiftMaster / Chamberlain
Linear
Manaras
Micanan
Raynor
VE Power Door
Cookson
Lawrence
Blue
T3
Diode Capacitor
Overhead Door (Only)
Red
T4
Capacitor
Linear (Transmitter)
White
T5
6.8K Ohm Resistor
Custom Applications
Orange
T6
270K Ohm Resistor
LiftMaster CPS Board
Violet
LiftMaster
None
2 Wire Edge Designator
ex. ME123-2U-12-T2
4 Wire Edge Designator
ex. ME123-4U-12
N/A
Outlet Wire Color Code
*Subject to change.
Please contact Miller Edge or your operator manufacturer for current compliance information
1
Miller Edge Ordering Guide
Effective 07-27-2011*
CORNELL MG/SG / US GEAR
Operator Manufacturer
Monitored Device
Cornell / US Gear
SENSING EDGE
NO SIGNATURE MODULE REQUIRED
Use any 2 wire monitored
Miller Edge model beginning with
ME, MT, MU, CPT with a
T2* Designator
Example: ME110-2R-12-T2
Ancillary Device
Any 2 Wire Normally Open
(N.O.) - ME, MT, MU, CPT,
Air- Wave, Pneumatic,
Invisi-Guard,
Light Curtain, Patriot, or
Photo Eye
or
PHOTO EYE
Operator Provided Monitored
Photo Eye
Monitored Device Wiring Diagram
Operator EM105EHL
2 Wired Monitored
Sensing Edge
Main Control
Board
BLACK
E6
E5
ME, MT, MU, CPT Edges
with T2 (10KΩ)
WHITE
Sensing Module ELR
Make sure the sensing module ELR is connected to
the main control at “CN8-Sensing Device”
* T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire
*Subject to change.
Please contact Miller Edge or your operator manufacturer for current compliance information
2
Miller Edge Ordering Guide
Effective 07-27-2011*
LIFTMASTER / CHAMBERLAIN
Operator Manufacturer
Monitored Device
Ancillary Device
SENSING EDGE
USE CPS-MEI Module from
Chamberlain with any
2 wire monitored Miller Edge model
beginning with ME, MT, MU, CPT
with a T2* Designator
Example: ME123-2U-12-T2
or
PHOTO EYE
Operator Provided Monitored
Photo Eye
Liftmaster/ Chamberlain
Any 2 Wire Normally Open
(N.O.) - ME, MT, MU, CPT,
Air- Wave, Pneumatic,
Invisi-Guard, Light Curtain,
Patriot, or Photo Eye
Monitored Device Wiring Diagrams
Logic 4 Operator
2 WIRE MONITORED SENSING EDGE
COMMON
BLACK
RED
RED
WHITE
LMEP1
CPT223/ME/MT/MU
CPS-MEI
Medium Duty
Logic Operator
2 WIRE MONITORED SENSING EDGE
LMEP1
LMEP2
BLACK
RED
RED
WHITE
CPT223/ME/MT/MU
CPS-MEI
CPS-MEI
Fire Door Operator
1
2
2 WIRE MONITORED SENSING EDGE
BLACK
RED
RED
WHITE
CPT223/ME/MT/MU
CPS-MEI
CPS-MEI
* T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire
*Subject to change.
Please contact Miller Edge or your operator manufacturer for current compliance information
3
Miller Edge Ordering Guide
Effective 07-27-2011*
LINEAR
Operator Manufacturer
Monitored Device
Ancillary Device
Linear
SENSING EDGE
Any 2 Wire Normally Open
(N.O.) - ME, MT, MU, CPT,
Air- Wave, Pneumatic,
Invisi-Guard,
Light Curtain, Patriot, or
Photo Eye
USE SM-102 with
any 2 wire monitored Miller
Edge model beginning with
ME, MT, MU, CPT with a
T2* Designator
Example: ME123-2U-12-T2
or
PHOTO EYE
Operator Provided Monitored
Photo Eye
Monitored Device Wiring Diagram
2 Wired Monitored
Sensing Edge
Linear M50JE5011S
Operator
PHOTO
COM
RED
BLACK
SM-102
RED
ME, MT, MU, CPT Edges
with T2 (10KΩ)
WHITE
* T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire
*Subject to change.
Please contact Miller Edge or your operator manufacturer for current compliance information
4
Miller Edge Ordering Guide
Effective 07-11-2011
MANARAS - OPERA
Operator Manufacturer
Manaras
Monitored Device
Ancillary Device
SENSING EDGE
Any 2 Wire Normally Open
(N.O.) - ME, MT, MU, CPT,
Air- Wave, Pneumatic,
Invisi-Guard,
Light Curtain, Patriot, or
Photo Eye
USE SM-102 with
any 2 wire monitored Miller
Edge model beginning with
ME, MT, MU, CPT with a
T2* Designator
Example: ME123-2U-12-T2
or
PHOTO EYE
Operator Provided Monitored
Photo Eye
Monitored Device Wiring Diagram
2 Wired Monitored
Sensing Edge
* T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire
*Subject to change.
Please contact Miller Edge or your operator manufacturer for current compliance information
5
Miller Edge Ordering Guide
Effective 07-27-2011*
MICANAN
Operator Manufacturer
Monitored Device
SENSING EDGE
Micanan
USE SM-102 with
any 2 wire monitored Miller
Edge model beginning with
ME, MT, MU, CPT with a
T2* Designator
Example: ME123-2U-12-T2
Ancillary Device
Any 2 Wire Normally Open
(N.O.) - ME, MT, MU, CPT,
Air- Wave, Pneumatic,
Invisi-Guard,
Light Curtain, Patriot, or
Photo Eye
or
PHOTO EYE
Operator Provided Monitored
Photo Eye
Monitored Device Wiring Diagram
2 Wired Monitored
Sensing Edge
Micanan PRO-H
Operator
BEAM 1
BEAM 2
EDGE 1
EDGE 2
RED
BLACK
SM-102
RED
ME, MT, MU, CPT Edges
with T2 (10KΩ)
WHITE
Factory Installed
* T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire
*Subject to change.
Please contact Miller Edge or your operator manufacturer for current compliance information
6
Miller Edge Ordering Guide
Effective 07-27-2011*
OVERHEAD DOOR
Operator Manufacturer
Overhead Door
Monitored Device
SENSING EDGE
USE Miller Edge P/N SM-101
or
Overhead Door P/N OPAKMEIX.S
with any 2 wire monitored Miller
Edge model beginning with
ME, MT, MU, CPT with a
T3**Designator
or
PHOTO EYE
Ancillary Device
Any 2 Wire Normally Open
(N.O.) - ME, MT, MU, CPT,
Air- Wave, Pneumatic,
Invisi-Guard, Light Curtain,
Patriot, or Photo Eye
Operator Provided Monitored
Photo Eye
Monitored Device Wiring Diagram
Overhead Door OPRMX/RSX
Set “ODC_STB=ON” in operator
2 Wired Monitored
Sensing Edge
Operator
ODC STB
ODC STB
RED
RED
SM-101
OPAKMEIX.S
BLACK
ME, MT, MU, CPT Edges
with T3
WHITE
** T3 - an embedded diode capacitor with a Red Band on the edge outlet wire
*Subject to change.
Please contact Miller Edge or your operator manufacturer for current compliance information
7
Miller Edge Ordering Guide
Effective 07-27-2011*
RAYNOR
Operator Manufacturer
Monitored Device
SENSING EDGE
Raynor
USE SM-102 with
any 2 wire monitored Miller
Edge model beginning with
ME, MT, MU, CPT with a
T2* Designator
Example: ME123-2U-12-T2
Ancillary Device
Any 2 Wire Normally Open
(N.O.) - ME, MT, MU, CPT,
Air- Wave, Pneumatic,
Invisi-Guard,
Light Curtain, Patriot, or
Photo Eye
or
PHOTO EYE
Operator Provided Monitored
Photo Eye
Monitored Device Wiring Diagrams
2 Wired Monitored
Sensing Edge
Raynor
Operator
PHOTO
COM
RED
BLACK
SM-102
RED
ME, MT, MU, CPT Edges
with T2 (10KΩ)
WHITE
* T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire
*Subject to change.
Please contact Miller Edge or your operator manufacturer for current compliance information
8
Miller Edge Ordering Guide
Effective 07-27-2011*
VE POWER DOOR
Operator Manufacturer
Monitored Device
SENSING EDGE
VE Power Door
USE SM-102 with
any 2 wire monitored Miller
Edge model beginning with
ME, MT, MU, CPT with a
T2* Designator
Example: ME123-2U-12-T2
or
PHOTO EYE
Operator Provided Monitored
Photo Eye
Ancillary Device
Any 2 Wire Normally Open
(N.O.) - ME, MT, MU, CPT,
Air- Wave, Pneumatic,
Invisi-Guard,
Light Curtain, Patriot, or
Photo Eye
COOKSON
Operator Manufacturer
Monitored Device
SENSING EDGE
NO SIGNATURE MODULE REQUIRED
Use any 2 wire monitored
Miller Edge model beginning with
ME, MT, MU, CPT with a
T2* Designator
Example: ME110-2R-12-T2
or
PHOTO EYE
Operator Provided Monitored
Photo Eye
Cookson
Ancillary Device
Any 2 Wire Normally Open
(N.O.) - ME, MT, MU, CPT,
Air- Wave, Pneumatic,
Invisi-Guard,
Light Curtain, Patriot, or
Photo Eye
LAWRENCE
Operator Manufacturer
Monitored Device
Ancillary Device
SENSING EDGE
Lawrence
NO SIGNATURE MODULE REQUIRED
Use any 2 wire monitored
Miller Edge model beginning with
ME, MT, MU, CPT with a
T2* Designator
Example: ME110-2R-12-T2
or
PHOTO EYE
Operator Provided Monitored
Photo Eye
Any 2 Wire Normally Open
(N.O.) - ME, MT, MU, CPT,
Air- Wave, Pneumatic,
Invisi-Guard,
Light Curtain, Patriot, or
Photo Eye
* T2 - an embedded 10KΩ resistor with a Blue Band on the edge outlet wire
*Subject to change.
Please contact Miller Edge or your operator manufacturer for current compliance information
9
Download