FLC100 LED – Total Flexibility Mounting Variations Integral (Type 2 or Type 3) Outreach Arm (Type 4) RAIL66 (Type 7) WE-EF Copyright 2012 1 FLC100 LED – Total Flexibility Size Variations FLC121 (6 LED Variation) FLC131 (12 LED Variation) FLC141 (24 LED Variation) WE-EF Copyright 2012 2 FLC100 LED – Total Flexibility Beam Variations Wide Medium Very Narrow Very Narrow ‚sharp cut-off‘ WE-EF Copyright 2012 3 FLC100 LED – Total Flexibility Beam Variations + Medium + IO-180° (Linear Spread Lens) Very Narrow + IO-180° (Linear Spread Lens) Very Narrow ‚sharp cut-off‘+ IO-180° (Linear Spread Lens) WE-EF Copyright 2012 4 FLC100 LED – Total Flexibility FLC121 6 LED 12W / 700 mA (XP-E) 1162 lm / 4000 K*/** *Nominal lumen output based on manufacturers data at 25°C Tj **As of first quarter 2013, for latest data refer to www.we-ef.com WE-EF Copyright 2012 5 FLC100 LED – Total Flexibility FLC121 6 LED 12W / 700 mA (XP-E) 1162 lm / 4000 K*/** *Nominal lumen output based on manufacturers data at 25°C Tj **As of first quarter 2013, for latest data refer to www.we-ef.com WE-EF Copyright 2012 6 FLC100 LED – Total Flexibility FLC131 12 LED 24W / 700 mA (XP-E) 2324 lm / 4000 K*/** *Nominal lumen output based on manufacturers data at 25°C Tj **As of first quarter 2013, for latest data refer to www.we-ef.com WE-EF Copyright 2012 7 FLC100 LED – Total Flexibility FLC131 12 LED 24W / 700 mA (XP-E) 2324 lm / 4000 K*/** *Nominal lumen output based on manufacturers data at 25°C Tj **As of first quarter 2013, for latest data refer to www.we-ef.com WE-EF Copyright 2012 8 FLC100 LED – Total Flexibility FLC141 24 LED 36W / 500 mA (XP-E) 3570 lm / 4000 K*/** *Nominal lumen output based on manufacturers data at 25°C Tj **As of first quarter 2013, for latest data refer to www.we-ef.com WE-EF Copyright 2012 9 FLC100 LED – Total Flexibility FLC141 24 LED 36W / 500 mA (XP-E) 3570 lm / 4000 K*/** *Nominal lumen output based on manufacturers data at 25°C Tj **As of first quarter 2013, for latest data refer to www.we-ef.com WE-EF Copyright 2012 10 FLC100 LED – Total Flexibility Features Mechanical IP66/IP55, Class I. IK08. Marine-grade, die-cast aluminium alloy High Pressure Die-cast PCS hardware 5CE superior corrosion protection WE-EF Copyright 2012 11 FLC100 LED – Total Flexibility Features Mechanical Built in heat sinks Two cable entries for looping IP66 between gear and lamp chamber, with o-ring for cable protection between both WE-EF Copyright 2012 12 FLC100 LED – Total Flexibility Features Electrical Surge Protection Built in surge protection Bypass device. If one LED fails, it is removed from the circuit guaranteeing the remaining LEDs continue to Bypass Device function Optional NTC (Negative Temperature Coefficient) thermocouple monitoring of LEDs to a preprogrammed and safe level; in the event of overheating (say operating during daytime) the lumen output will be reduced by 50%. WE-EF Copyright 2012 13 FLC100 LED – Total Flexibility Features Electrical LED Lifetime > 60.000 hrs Lifetime B10/L70 Ta = 25° Control Gear Lifetime > 50.000 hrs Ta = 25° WE-EF Copyright 2012 14 FLC100 LED – Total Flexibility Features Performance Wide Beam Single PMMA-LED lens array (less parts and easily exchanged) Developed in-house Medium Beam Very Narrow Beam Very Narrow ‚sharp cut-off‘ WE-EF Copyright 2012 15 FLC100 LED – Total Flexibility Art # 146146-0495 Description FLC131 12 LED 24W [B] LOR 68.1% Half Peak Max. [cd/klm] 2 x 25° 25 869 Features Performance (Type 2) Wide Beam 146146-0400 FLC131 12 LED 24W [M] 74.7 % 2 x 15° 15 2353 Medium Beam 146146-0498 FLC131 12 LED 24W [EE] 69.9 % 2 x 6° 6 9210 Very Narrow Beam 146146-0403 FLC131 12 LED 24W [EES] 75.1 % 2 x 4° 4 28504 Very Narrow Beam ‚sharp cut-off‘ WE-EF Copyright 2012 16 FLC100 LED – Total Flexibility Features Performance IES FILE ‚Cold‘ Lumens ‚Hot‘ Lumens Total System Watts WE-EF Copyright 2012 17 FLC100 LED – Total Flexibility Features Performance Conventional projector luminaires have used aluminium reflectors to control the light. There are efficiency losses due to; reflection, shielding (indirect) and spill (direct) ...Spill ungerichteter Direktanteil ...Shielding Abschirmung ...Reflection Reflektion WE-EF Copyright 2012 18 FLC100 LED – Total Flexibility Features Performance Light Loss via: Transmission LED projector luminaires have the advantage that the light can be directed more efficiently at the object or area The optical lens is constructed of a clear PMMA (acrylic), which has an optical efficiency of around 98 % An LED projector theoretically requires 25 % less lumens than conventional reflector engineered projectors WE-EF Copyright 2012 19 FLC100 LED – Total Flexibility Features Accessories Optical Linear Spread Lens (Internal) Wire Guard (External) Glare Shield (External) Snoot (External) WE-EF Copyright 2012 20 FLC100 LED – Total Flexibility Features Accessories Mechanical (Type 2/3 and Type 4) Pipe Clamp SP1/SP2 Pipe Clamp (Single or Twin). Suitable for FLC131/141 and diameters 38-60 mm or 76 – 89 mm Short Post EM1 Short Post (Optional lengths available) Junction Box JB 1 WE-EF Copyright 2012 Junction Box (Wall Mounted) 21 FLC100 LED – Total Flexibility Universal Features Accessories Mechanical (RAIL 66 aka Type 7) Universal is suitable for installation in any desired Surface Fitters orientation to walls, under roof and ceiling structures (2 – 6 Projectors 1150 – 2150 mm) The optional Flat Surface Fitters (pair) provide enhanced mounting surface coverage and facilitate concealing of a receased junction box Pole Fitters The optional Pole Fitters (pair) allow installtion to pipe structures and columns of minimum 100 mm diameter WE-EF Copyright 2012 22 FLC100 LED – Total Flexibility Features Accessories Cantilever Mechanical (RAIL 66 aka Type 7) Cantilever features a concealed termination chamber and has been designed for horizontal wall mounting Ideal for facade lighting applications Mobile Mobile includes 3 m of flexible cable and plug Ideal for mobile installations like showrooms, exhibitions or outdoor events WE-EF Copyright 2012 23 FLC100 LED – Total Flexibility WE-EF Copyright 2012 24 FLC100 LED – Total Flexibility Features High pressure die cast aluminium construction with integrated heat sink Benefits Marine grade ALSi12/LM6/CP401 aluminium alloy Body and frame are HPDC; precision, strength, repeatability, low tolerance. Optimal thermal management for LED and control gear Excellent corrosion protection Variety of Mounting Options (Type 2/3, Type 4, Type 7) Flexibility for a tailored lighting solution Silicone gasket (single formed one piece) Operates for longer life. PCS (polymer coated system) stainless steel fasteners 15% Teflon for friction reduced action and reduced risk of binding. Reduced friction between male and female thread causes tighter fit between connected parts. Prevents galvanic corrosion that otherwise occurs, when metals of dissimilar electro-negatives are in contact Dust tight and high pressure water jet tight/Dust proof and Jet proof; long life, suitable for commercial and industrial applications, improved seal quality means less internal pollution and higher maintenance factors IP66/IP55 protection rating for complete luminaire High ambient temperature rating 25°C High reliability, extended component life. Optical grade PMMA Lenses High Optical Efficiency of over 98%. Option [B], [M], [EE] and [EES] Lenses Choice and flexibility in the design process. Suitable for a wide range of application (from spot to facade lighting) On average 70% Lumen maintenance > 50.000 hrs. Lifetime not affected by on/off switching Controls temperature variations, to protect LEDs from overheating High efficiency, High quality, High output LED’s. Built in thermal management system (optional) eg. Thermocouple monitoring to a preprogrammed and safe level 3000 K and 4000 K WE-EF Copyright 2012 Ability to match other light sources in the design process and balance efficiency and ambience. 25