FLC100 LED – Total Flexibility Mounting Variations - WE-EF

advertisement
FLC100 LED – Total Flexibility
Mounting Variations
Integral (Type 2 or Type 3)
Outreach Arm (Type 4)
RAIL66 (Type 7)
WE-EF Copyright 2012
1
FLC100 LED – Total Flexibility
Size Variations
FLC121 (6 LED Variation)
FLC131 (12 LED Variation)
FLC141 (24 LED Variation)
WE-EF Copyright 2012
2
FLC100 LED – Total Flexibility
Beam Variations
Wide
Medium
Very Narrow
Very Narrow ‚sharp cut-off‘
WE-EF Copyright 2012
3
FLC100 LED – Total Flexibility
Beam Variations +
Medium + IO-180° (Linear Spread Lens)
Very Narrow + IO-180° (Linear Spread Lens)
Very Narrow ‚sharp cut-off‘+ IO-180° (Linear Spread
Lens)
WE-EF Copyright 2012
4
FLC100 LED – Total Flexibility
FLC121
6 LED 12W / 700 mA (XP-E)
1162 lm / 4000 K*/**
*Nominal lumen output based on manufacturers data at 25°C Tj
**As of first quarter 2013, for latest data refer to www.we-ef.com
WE-EF Copyright 2012
5
FLC100 LED – Total Flexibility
FLC121
6 LED 12W / 700 mA (XP-E)
1162 lm / 4000 K*/**
*Nominal lumen output based on manufacturers data at 25°C Tj
**As of first quarter 2013, for latest data refer to www.we-ef.com
WE-EF Copyright 2012
6
FLC100 LED – Total Flexibility
FLC131
12 LED 24W / 700 mA (XP-E)
2324 lm / 4000 K*/**
*Nominal lumen output based on manufacturers data at 25°C Tj
**As of first quarter 2013, for latest data refer to www.we-ef.com
WE-EF Copyright 2012
7
FLC100 LED – Total Flexibility
FLC131
12 LED 24W / 700 mA (XP-E)
2324 lm / 4000 K*/**
*Nominal lumen output based on manufacturers data at 25°C Tj
**As of first quarter 2013, for latest data refer to www.we-ef.com
WE-EF Copyright 2012
8
FLC100 LED – Total Flexibility
FLC141
24 LED 36W / 500 mA (XP-E)
3570 lm / 4000 K*/**
*Nominal lumen output based on manufacturers data at 25°C Tj
**As of first quarter 2013, for latest data refer to www.we-ef.com
WE-EF Copyright 2012
9
FLC100 LED – Total Flexibility
FLC141
24 LED 36W / 500 mA (XP-E)
3570 lm / 4000 K*/**
*Nominal lumen output based on manufacturers data at 25°C Tj
**As of first quarter 2013, for latest data refer to www.we-ef.com
WE-EF Copyright 2012
10
FLC100 LED – Total Flexibility
Features Mechanical
IP66/IP55, Class I. IK08.
Marine-grade, die-cast aluminium alloy
High Pressure Die-cast
PCS hardware
5CE superior corrosion protection
WE-EF Copyright 2012
11
FLC100 LED – Total Flexibility
Features Mechanical
Built in heat sinks
Two cable entries for looping
IP66 between gear and lamp chamber, with o-ring for
cable protection between both
WE-EF Copyright 2012
12
FLC100 LED – Total Flexibility
Features Electrical
Surge Protection
Built in surge protection
Bypass device. If one LED fails, it is removed from the
circuit guaranteeing the remaining LEDs continue to
Bypass Device
function
Optional NTC (Negative Temperature Coefficient)
thermocouple monitoring of LEDs to a preprogrammed and safe level; in the event of
overheating (say operating during daytime) the lumen
output will be reduced by 50%.
WE-EF Copyright 2012
13
FLC100 LED – Total Flexibility
Features Electrical
LED
Lifetime > 60.000 hrs
Lifetime B10/L70
Ta = 25°
Control Gear
Lifetime > 50.000 hrs
Ta = 25°
WE-EF Copyright 2012
14
FLC100 LED – Total Flexibility
Features Performance
Wide Beam
Single PMMA-LED lens array
(less parts and easily exchanged)
Developed in-house
Medium Beam
Very Narrow Beam
Very Narrow ‚sharp cut-off‘
WE-EF Copyright 2012
15
FLC100 LED – Total Flexibility
Art #
146146-0495
Description
FLC131 12 LED 24W [B]
LOR
68.1%
Half Peak
Max.
[cd/klm]
2 x 25°
25
869
Features Performance (Type 2)
Wide Beam
146146-0400
FLC131 12 LED 24W [M]
74.7 %
2 x 15°
15
2353
Medium Beam
146146-0498
FLC131 12 LED 24W [EE]
69.9 %
2 x 6°
6
9210
Very Narrow Beam
146146-0403
FLC131 12 LED 24W [EES]
75.1 %
2 x 4°
4
28504
Very Narrow Beam ‚sharp cut-off‘
WE-EF Copyright 2012
16
FLC100 LED – Total Flexibility
Features Performance
IES FILE
‚Cold‘ Lumens
‚Hot‘ Lumens
Total System Watts
WE-EF Copyright 2012
17
FLC100 LED – Total Flexibility
Features Performance
Conventional projector luminaires have used
aluminium reflectors to control the light.
There are efficiency losses due to; reflection,
shielding (indirect) and spill (direct)
...Spill
ungerichteter
Direktanteil
...Shielding
Abschirmung
...Reflection
Reflektion
WE-EF Copyright 2012
18
FLC100 LED – Total Flexibility
Features Performance
Light Loss via: Transmission
LED projector luminaires have the advantage that the
light can be directed more efficiently at the object or
area
The optical lens is constructed of a clear PMMA
(acrylic), which has an optical efficiency of around
98 %
An LED projector theoretically requires 25 % less
lumens than conventional reflector engineered
projectors
WE-EF Copyright 2012
19
FLC100 LED – Total Flexibility
Features Accessories
Optical
Linear Spread Lens (Internal)
Wire Guard (External)
Glare Shield (External)
Snoot (External)
WE-EF Copyright 2012
20
FLC100 LED – Total Flexibility
Features Accessories
Mechanical (Type 2/3 and Type 4)
Pipe Clamp SP1/SP2
Pipe Clamp (Single or Twin). Suitable for FLC131/141
and diameters 38-60 mm or 76 – 89 mm
Short Post EM1
Short Post (Optional lengths available)
Junction Box JB 1
WE-EF Copyright 2012
Junction Box (Wall Mounted)
21
FLC100 LED – Total Flexibility
Universal
Features Accessories
Mechanical (RAIL 66 aka Type 7)
Universal is suitable for installation in any desired
Surface Fitters
orientation to walls, under roof and ceiling structures
(2 – 6 Projectors 1150 – 2150 mm)
The optional Flat Surface Fitters (pair) provide
enhanced mounting surface coverage and facilitate
concealing of a receased junction box
Pole Fitters
The optional Pole Fitters (pair) allow installtion to pipe
structures and columns of minimum 100 mm diameter
WE-EF Copyright 2012
22
FLC100 LED – Total Flexibility
Features Accessories
Cantilever
Mechanical (RAIL 66 aka Type 7)
Cantilever features a concealed termination chamber
and has been designed for horizontal wall mounting
Ideal for facade lighting applications
Mobile
Mobile includes 3 m of flexible cable and plug
Ideal for mobile installations like showrooms,
exhibitions or outdoor events
WE-EF Copyright 2012
23
FLC100 LED – Total Flexibility
WE-EF Copyright 2012
24
FLC100 LED – Total Flexibility
Features
High pressure die cast aluminium construction with integrated heat sink
Benefits
Marine grade ALSi12/LM6/CP401 aluminium alloy
Body and frame are HPDC; precision, strength, repeatability, low tolerance. Optimal thermal
management for LED and control gear
Excellent corrosion protection
Variety of Mounting Options (Type 2/3, Type 4, Type 7)
Flexibility for a tailored lighting solution
Silicone gasket (single formed one piece)
Operates for longer life.
PCS (polymer coated system) stainless steel fasteners
15% Teflon for friction reduced action and reduced risk of binding. Reduced friction between
male and female thread causes tighter fit between connected parts. Prevents galvanic
corrosion that otherwise occurs, when metals of dissimilar electro-negatives are in contact
Dust tight and high pressure water jet tight/Dust proof and Jet proof; long life, suitable for
commercial and industrial applications, improved seal quality means less internal pollution and
higher maintenance factors
IP66/IP55 protection rating for complete luminaire
High ambient temperature rating 25°C
High reliability, extended component life.
Optical grade PMMA Lenses
High Optical Efficiency of over 98%.
Option [B], [M], [EE] and [EES] Lenses
Choice and flexibility in the design process. Suitable for a wide range of application (from spot
to facade lighting)
On average 70% Lumen maintenance > 50.000 hrs. Lifetime not affected by on/off switching
Controls temperature variations, to protect LEDs from overheating
High efficiency, High quality, High output LED’s.
Built in thermal management system (optional) eg. Thermocouple monitoring to a preprogrammed and safe level
3000 K and 4000 K
WE-EF Copyright 2012
Ability to match other light sources in the design process and balance efficiency and ambience.
25