Rectifier R48-400

advertisement
�������������
����������������������������
Rectifier
R48-400
DC Power
Mini rectifier
-48 V DC, 400 W
Features and benefits
Low rectifier/subrack height
– minimize space needed
for power in embedded
applications
DSP (Digital Signaling
Processor) – means fewer
components, optimized
operation and active load
sharing for increased
reliability
Compliant with global
standards – delivers quality,
performance and reliability
no matter what the application or location demands
Hot pluggable – facilitates
future extensions
Wide input voltage range
– operates in the most
demanding environments
where input voltage changes
Wide temperature operating
range (-40°C / -40 °F to
+75°C / 167°F) – meets the
harshest climatic environment
requirements
The R48-400 rectifier converts standard AC supply voltages into
stable nominal -48 V DC voltage adjustable to the needs of the
application. The R48-400 is a constant power rectifier designed
with the latest patented switch-mode technology using DSP
(Digital Signaling Processor) functionality for efficient operation.
For a higher load capacity, rectifiers can be connected in parallel
and intelligent control can be added with the help of a separate
controller.
Technical Specifications, R48-400
AC input
Input voltage, nominal
Input voltage, permitted variation
Line frequency
Max input current
Power factor
100 to 250 V AC
85 to 300 V AC
45 to 65 Hz
3A
0.95
DC output
Output voltage, adjustment range
Output power
Output power, derated for input voltage
Output current
Efficiency
Psophometric noise (system)
Temperature derating
-42 to –58 V DC
400 W @ Vout >45 V DC
See diagram
9 A @ -45 V DC
86 %
<1mV at 5 to 100% of rated load <32 dBrnc at 5 to 100% of rated load
See diagram
Control and monitoring
Rectifier alarm and signalling
Visual indications
Alarm and status reported via CAN bus to system Controller
Green LED = Normal operation; Yellow LED = Alarm;
Red LED = Failure; Flashing red LED = Fan failure
Environmental
Temperature range, operating
Temperature range, storage
Relative humidity
Altitude
EMC
Safety
-40 to +75°C, -40 to +167°F
-40 to +75°C, -40 to +167°F
0 to 90%
2000 m, 6560 ft at full power
EN 300 386:2001 class B, FCC part 15 class B
IEC 60950, EN 60950, UL 60950
Mechanics
Dimensions (HxWxD)
Weight
81 x 40 x 285 mm (3.181 x 1.575 x 11.22 inches)
1.1 kg (2.43 lbs)
Other parts
Controller units
See separate ACU,SCU and LAU datasheets
Emerson Network Power
Energy Systems AB
SE-141 82 Stockholm, Sweden
Phone: +46 8 721 60 00
Fax: +46 8 721 71 77
Emerson Network Power
Energy Systems, North America
1122 ”F” Street, Lorain, OH 44052
Phone: 440-246-6999
Fax: 440-246-4876
www.emersonnetworkpower.com/
energysystems/
Emerson Network Power
Co Ltd., China
No. 1 Kefa Rd., Science &
Industry Park
Nanshan District 518057,
Shenzhen, China
Phone: 86-755-860 108 08
www.emersonnetworkpower.com.cn
Ordering information
Product name
Rectifier R48-400
����������������������������������������������
����������������������������������������������
For global contact, visit:
www.emersonenergy.com
��
��
����������������
����������������
���
���
���
���
���
���
���
���
���
���
�
�
��� ���
��� ��� ���
�
��
��
��
��
��
��
��
��
��� ���
��� ��� ���
�
��
��
��
��
��
��
��
��
����������������
����������������
���������������������������������������������
���������������������������������������������
�� ���
�� ���
����������������
����������������
���
���
���
���
���
���
���
���
���
���
�
�
�
��
��
�
���
���
���
���
��������������������
��������������������
���
���
EN/LZT 145 249 RA
© Emerson Network Power Energy Systems 2005
����������������������
�����������������������������
�����������������������������
��������
������������
��������
��������������
�������������
����������������������������
�������������
�����������������
����������������������������
�������������������������
��������������������������������������
��������������������������������������
���������������������������������������
��������������������������