2/2013 ANCHOR BOLTS INSTRUCTIONS FOR USE - Threaded rebars ATP, AHP, AJP - Threaded high strength steel bolts ALP-L, ALP-P, AMP ATP AHP ALP-L ALP-P AMP Eurocode design according to EN1993-1-8 (2005) & EN 1992-1-1 (2004) Certified Finnish product manual (NA: FIN) ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi CONTENTS page 2 Anchor bolts Instructions for use Page 1 PRODUCT DESCRIPTION ...................................................................................................................................3 2 MATERIALS AND STRUCTURE ........................................................................................................................3 2.1 PRODUCT RANGE ...............................................................................................................................................3 2.2 MATERIALS .......................................................................................................................................................3 2.3 MANUFACTURING ..............................................................................................................................................3 2.4 QUALITY CONTROL ............................................................................................................................................3 2.5 DIMENSIONS ......................................................................................................................................................4 2.5.1 ATP and AHP rebar bolts .............................................................................................................................4 2.5.2 ALP anchor bolts..........................................................................................................................................5 2.5.3 AMP anchor bolts ........................................................................................................................................6 3 CAPACITIES..........................................................................................................................................................7 3.1 BASIS OF DESIGN ................................................................................................................................................7 3.2 BOLT CAPACITIES ..............................................................................................................................................7 3.3 COMBINED LOADINGS ........................................................................................................................................7 4 THE USE OF ANCHOR BOLTS..........................................................................................................................8 4.1 RESTRICTIONS ...................................................................................................................................................8 4.2 DESIGN PRINCIPLES ............................................................................................................................................8 4.3 PLACING OF BOLTS.............................................................................................................................................9 4.3.1 Minimum bolt edge distances for normal forces............................................................................................9 4.3.2 Minimum bolt centre to centre distances for normal forces...........................................................................9 4.3.3 Minimum bolt edge distances for shear force................................................................................................9 4.4 ADDITIONAL REINFORCEMENT.......................................................................................................................... 10 4.4.1 Connection reinforcing principle................................................................................................................ 10 4.4.2 Column to column joint .............................................................................................................................. 10 4.4.3 Placing short stud head anchor bolts in slabs or low foundations ............................................................... 10 4.4.4 Placing short stud head anchors in a foundation column ............................................................................ 11 4.4.5 Placing rebar bolts in a foundation column ................................................................................................ 11 4.4.6 Placing AMP bolts in a column .................................................................................................................. 12 4.5 ADDITIONAL CLAUSES FOR T40 REBAR.............................................................................................................. 13 4.6 CORRECTION OF CAPACITY VALUES .................................................................................................................. 13 4.6.1 Change of concrete strength ....................................................................................................................... 13 4.6.2 Small edge distance .................................................................................................................................... 13 4.6.3 Small centre to centre distance ................................................................................................................... 13 4.6.4 Durability and concrete cover .................................................................................................................... 14 5 INSTALLATION .................................................................................................................................................. 14 5.1 FORMING A BOLT GROUP .................................................................................................................................. 14 5.2 BOLT ASSEMBLY AND TOLERANCES .................................................................................................................. 15 5.3 BENDING AND WELDING OF BOLTS .................................................................................................................... 15 5.4 COLUMN INSTALLATION ................................................................................................................................... 15 5.5 SAFETY PRECAUTIONS ...................................................................................................................................... 16 5.6 INSTALLATION CONTROL.................................................................................................................................. 16 5.6.1 Instructions for bolt assembly ..................................................................................................................... 16 5.6.2 Instructions for column installation ............................................................................................................ 16 Download free from www.anstar.fi ColJoint design program for bolt/column shoe connection ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi 1 page 3 Anchor bolts Instructions for use PRODUCT DESCRIPTION The anchor bolt transfers forces acting in the bar direction to foundation or lower column by rebar bond or by stud head anchoring. Connection shear force is transferred to the concrete structure by the concrete edge pressure acting on the bolt shaft. 2 MATERIALS AND STRUCTURE 2.1 Product range The anchor bolt product range include following bolt types: ATP AHP ALP-L ALP-P AMP, -M Short rebar bolt with stud head anchor Rebar bolt with straight bonding rebar Short high strength anchor bolt with stud head anchors High strength anchor bolt with straight rebars Standard bolt for moment stiff connection between precast beam and column Beside the bolt the standard delivery contains 2 nuts and 2 round washers. For the AMP bolt lower nut and washer can be replaced with a round threaded steel plate. 2.2 Materials Rebar T16-T32 Rebar T40 ALP thread Nut Washer 2.3 SFS 1215 (EN 10080) NS3576-3 High strength steel Imacro M, Ovako DIN 934 EN 10025 A500HW (B500B), f y = 500 N/mm² B500NC fy = 700 N/mm² fu = 800-1100 N/mm² Grade m8 ATP, AHP Grade m10 ALP, AMP Grade S235JR+AR Manufacturing Method of manufacturing Rebars and bolt materials are mechanically cut Anchors are MAG welded with a robot or by hand to high strength steel bolt. Weld class C EN-ISO 5817. Threads M16-M52 are rolled and M60 is cut. Anchoring stud is hot forged and air cooled. Surface treatment options: 1) ‘Black steel’ with lightly oiled thread is standard supply 2) Hot dip galvanizing according to EN ISO 1461 including also nuts and washers - ATP and AHP bolts are galvanized troughout - threaded part of ALP and AMP bolt is galvanized before welding ‘black’ anchors Manufacturing tolerances Total bolt length Length of thread Metric thread ISO 965-1 2.4 ± 10 mm +5,-0 mm 6g Quality control The quality control follows the requirements set by the Finnish Code of Building Regulations. Anstar column shoes are certified by the Finnish Concrete Assosiation according to Eurocode and the exter- page 4 Anchor bolts Instructions for use ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi 2.5 nal quality control of manufacture is provided by Inspecta Sertifiointi Oy. Dimensions 2.5.1 ATP and AHP rebar bolts ATP and AHP rebar bolts are used to join columns to foundations in connections transferring normal forces, shear forces and bending moments. ATP bolts are used in connections where short anchoring lengths are needed, such as in slabs and short foundation columns. AHP bolts can be used in foundations where there is enough space for straight rebar anchoring. Ø K S T ATP D L washer Ø K AHP L Fig. 1. ATP and AHP foundation bolts Table 1. Dimensions of ATP and AHP anchor bolts (order AHP with desired L) Type ATP16 ATP20 ATP24 ATP30 ATP39 L mm 280 350 430 500 700 AHP16 AHP20 AHP24 AHP30 AHP39 800 1000 1200 1500 2000 other lengths in stock 1500, 2000, 2500, 3000 1500, 2000, 2500, 3000 2000, 2500, 3000 K mm 100 120 140 170 190 As mm2 157 245 353 561 976 M mm M16 M20 M24 M30 M39 Ø mm T16 T20 T25 T32 T40 D mm 36 46 58 73 100 S mm 38 46 55 65 90 T mm 5 6 6 8 8 weight kg 0,7 1,2 2,2 4,3 10,0 100 120 140 170 190 157 245 353 561 976 M16 M20 M24 M30 M39 T16 T20 T25 T32 T40 - 38 46 55 65 90 5 6 6 8 8 1,5 2,7 4,8 10,2 21,6 Also available as hot-dip galvanized. Table 2 and figure 2. Rebar lap length l0,min (EC2) for bolt tensile force concrete strength bond condition concrete cover percentage AHP16 AHP20 AHP24 AHP30 AHP39 1 2 6 C25/30 1,0 1,0 0,7 1,0 1,5 1,5 482 689 602 860 694 992 857 1224 1303 1861 1,0 0,7 1,5 574 720 898 1149 1561 C32/40 1,0 1,0 1,5 821 1027 1284 1642 2232 0,7 1,0 1,5 1174 1467 1833 2367 3187 l 0,min page 5 Anchor bolts Instructions for use ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi 2.5.2 ALP anchor bolts ALP anchor bolts are used to join columns to foundations in connections transferring normal forces, shear forces and bending moments. ALP-L bolts are used in connections where short anchoring lengths are needed, such as in slabs and short foundation columns. ALP-P bolts can be used in foundations where there is enough space for straight rebar anchoring. K Ø 50 ALP22L,..., -52L ALP60L D D ALP-L L K Ø 50 ALP36P ALP39P ALP45P ALP52P ALP60P ALP22P ALP27P D D ALP-P L Fig. 3. ALP anchor bolts Table 3. Dimensions of ALP anchor bolts Type ALP22L ALP27L ALP30L ALP36L ALP39L ALP45L ALP52L ALP60L L mm 490 620 650 740 860 970 1130 1290 K mm 140 170 170 180 190 210 240 270 As mm2 303 459 561 817 976 1306 1758 2362 M mm M22 M27 M30 M36 M39 M45 M52 M60 Ø mm 3T16 3T20 3T20 3T25 3T25 3T32 3T32 4T32 D mm 80 100 105 130 135 150 150 220 S mm 55 65 65 80 90 100 100 130 T mm 6 8 8 8 8 10 10 12 weight kg 2,6 5,0 5,7 10,0 12,6 22,5 27,2 39,6 ALP22P ALP27P ALP30P ALP36P ALP39P ALP45P ALP52P ALP60P 1070 1150 1370 1390 1490 1710 1880 2430 140 170 170 180 190 210 240 270 303 459 561 817 976 1306 1758 2362 M22 M27 M30 M36 M39 M45 M52 M60 3T12 3T16 3T16 4T16 4T20 4T20 4T25 4T32 70 80 85 105 115 135 150 180 55 65 65 80 90 100 100 130 6 8 8 8 8 10 10 12 3,6 6,7 8,0 11,8 17,7 23,6 36,3 70,0 Also available as hot-dip galvanized (only threaded bar – not anchors) L K Kj M Ø D S T = = = = = = = = Total length of bolt Length of thread Area of threaded cross-section Metric thread size Amount and diameter of rebars Combined anchor space needed Washer diameter Washer thickness page 6 Anchor bolts Instructions for use ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi 2.5.3 AMP anchor bolts AMP anchor bolts are used in moment stiff precast beam-to-column connections. Bolt dimensions have been designed for limited embedment space in concrete column. AMP bolts can also be used in connections where short anchoring lengths are needed, such as slabs and short foundation columns to transfer normal forces, shear forces and bending moments. AMP-M bolts are used to connect two precast beams facing opposite sides of the column. Product code is AMP-M-L (for example AMP52M-1480). AMP AMP-M U K Column width K A 50 50 Ø K 50 Ø B L L Fig. 4. AMP anchor bolts Table 4. Dimensions of AMP anchor bolts Type AMP36 AMP39 AMP45 AMP52 AMP60 AMP36M-L AMP39M-L AMP45M-L AMP52M-L AMP60M-L L K Kj M A B Ø U S = = = = = = = = = L mm 670 680 800 930 1490 K mm 180 190 210 240 270 As mm2 817 976 1306 1758 2362 M mm M36 M39 M45 M52 M60 A mm 160 180 200 230 270 B mm 80 90 100 115 130 Ø mm T25 T32 T32 T32 T40 U mm 137 140 165 190 270 S mm 80 90 100 100 130 weight kg 10,5 13,8 20,7 38,3 72,8 - 180 190 210 240 270 817 976 1306 1758 2362 M36 M39 M45 M52 M60 - - T25 T32 T32 T32 T40 - 80 90 100 100 130 - Total length of bolt Length of thread Area of threaded cross-section Metric thread size Length of anchor plate Width of anchor plate Diameter of rebars Anchor plate distance from thread Washer diameter ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi 3 CAPACITIES 3.1 Basis of design page 7 Anchor bolts Instructions for use The anchor bolts have been designed according to: Tension: EN 1993-1-1:2005 Design of Steel Structures, General rules EN 1993-1-8:2005 Design of Steel Structures, Joints Tension resistance has been calculated with M2 = 1,25 (NA: FIN) EN 1992-1-1:2004 Design of Concrete Structures, General rules Shear: - 3.2 Elastically embedded bolt with edge distance 10Ø according to De Beer A slightly conservative capacity compared to CEN/TS 1992-4-2:2009 chapter 6.3, suitable for anchoring machinery (smaller displacements in serviceability limit state) Bolt capacities The anchor bolts have been designed for tension and compression capacities calculated from the thread cross-section (EN 1993-1-8: 3.6). The bolt capacity is the same as the capacity for corresponding column shoe. Table 5. Design capacities for rebar bolts. Concrete C25/30. Bolt ATP16 ATP20 ATP24 ATP30 ATP39 good bond, AHP16 AHP20 AHP24 AHP30 AHP39 2 = 0,7 Normal force NRd [kN] 62.2 97.0 139.7 222.1 386.5 Shear force VRd [kN] 3.7 6.9 10.9 19.1 36.7 Corresponding column shoe APK16 APK20 APK24 APK30 AK39 Table 6. Design capacities for high strength steel bolts. Concrete C25/30. Bolt good bond, 2 = 0,7 ALP22L,-P ALP27L,-P ALP30L,-P ALP36L,-P AMP36, -M ALP39L,-P AMP39, -M ALP45L,-P AMP45, -M ALP52L,-P AMP52, -M ALP60L,-P AMP60, -M 3.3 Normal force NRd [kN] 174.5 264.4 323.1 470.6 562.2 752.2 1012.6 1340.0 Shear force VRd [kN] 15.2 25.2 33.4 52.8 64.6 88.7 123.9 168.3 Corresponding column shoe APK24 APK30 APK33 APK36 APK39 APK45 APK52 APK60 Combined loadings For combined tension and shear loads the following equation should be satisfied: (NEd / NRd)1,5 + (VEd / VRd)1,5 NEd NRd VEd VRd = = = = Design tension load Tension capacity Design shear load Shear capacity 1,0 page 8 Anchor bolts Instructions for use ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi 4 THE USE OF ANCHOR BOLTS 4.1 Restrictions Anchor bolt capacities have been determined for static loads. When designing dynamic actions larger load safety factors should be used and the connection system should be analysed for each case. Using capacity values require that the minimum centre to centre and edge distances as well as reinforcement instructions for transferring bolt loads to concrete are followed. Impact ductility properties of ALP and AMP bolt material enables normal usage to - 40 C. 4.2 Design principles In grouted joints bolts usually transfer only tension loads, while shear load is transferred by friction (EN 1993-1-8: 6.2.2). In ungrouted joints (installation) all loads will be carried by slender bolts. Shear loads are bending the threaded bolts and the compression side will determine the bolt size needed. Compression load acting on a bolt (symmetrical bolt group) NEdp = NEd / n + MEd / (0,5 * H * n) NEd MEd H n N Ed joint design compression load joint design bending load bolt c/c distance amount of joint bolts M Ed M Bolt bending moment caused by shear load Q Ed G MQEd = 0,5 * QEd * (G + M) / n QEd G M n joint design shear load grout thickness (mm) thread size (mm) amount of joint bolts Moment resistance MRd = 1,5 * f y * W x / 1,1 = 0,192 * f y * As As thread cross-section fy = 500 MPa (rebars) fy = 640 MPa (high strength steel) H 1,5 N Edp Combined action NEdp / NRd + MQEd / MRd < 1,0 Fig. 5. Joint design before grouting page 9 Anchor bolts Instructions for use ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi 4.3 Placing of bolts 4.3.1 Minimum bolt edge distances for normal forces AHP and ALP-P bolts The bolts require only an ordinary concrete cover thickness to the surface of the concrete structure according to EC2 chapter 4. ATP, ALP-L and AMP bolts The bolt minimum edge distances are determined for the stud head anchor. 4.3.2 Minimum bolt centre to centre distances for normal forces AHP and ALP-P bolts The bolts are placed according to requirements for lap spliced rebars. ATP, ALP-L and AMP bolts Bolt minimum centre to centre distances are determined for the stud head anchors. Table 7. Minimum edge and centre to centre distances for stud head anchors Bolt ATP16 ATP20 ATP24 ATP30 ATP39 Minimum distance [mm] e1 e2 e3 e4 38 76 47 94 56 112 71 142 A c1 93 186 ALP22L ALP27L ALP30L ALP36L ALP39L ALP45L ALP52L ALP60L 63 78 88 104 113 131 152 160 126 156 176 208 226 262 304 320 AMP36 AMP39 AMP45 AMP52 AMP60 75 80 90 100 110 150 160 180 200 220 ATP ALP-L A c1 e1 e2 e1 e2 AMP 115 125 150 180 215 230 250 300 360 430 A c1 A c1 e1 e2 e3 e4 4.3.3 Minimum bolt edge distances for shear force The bolt minimum edge distance for shear force is 10*Ø, if the shear force is transferred directly to concrete. If the edge distance is smaller the whole bolt shear force should be transferred using additional stirrups or U-bent rebars. page 10 Anchor bolts Instructions for use ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi 4.4 Additional reinforcement 4.4.1 Connection reinforcing principle Anchor bolts always require reinforcement of foundation and column so, that tension, compression and shear forces can be transferred to surrounding concrete. Following chapters describe some recommended reinforcing principles. 4.4.2 Column to column joint AHP bolts join precast concrete columns with steel shoes. The reinforcement should be designed according to following instructions, see figure 6. 1. Bolt tension and compression forces are transferred to the column by using a single main reinforcement bar corresponding to bolt or by using two smaller main reinforcement bars, the lap length of which must correspond to the bolt length. (see table 2) AHP Aqt + A st 2. All shear forces are transferred with the stirrup reinforcement Aqt. 3. Transverse stirrups Ast must be placed in both ends of the bolt according to EC2 section 8.7.4. These stirrups are given in table 9. A st Fig. 6. Reinforcing principle for column top 4.4.3 Placing short stud head anchor bolts in slabs or low foundations Tension load Concrete cone failure is resisted by surface reinforcement or when needed with additional bent bars Art. Compression load if Hmin 5*M if Hmin < 5*M ATP ALP-L no additional reinforcement is needed U-links or stirrups Apt should transfer the whole action Nd use AMP bolts M Art Apt H min Fig. 7. Placing ATP or ALP-L bolts into a slab page 11 Anchor bolts Instructions for use ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi 4.4.4 Placing short stud head anchors in a foundation column Stud head bolts can also be placed into foundation columns. The reinforcement of the columns should be designed in the following manner: 1. Tension forces acting in the bolt should be transferred to the foundation by using main rebars bent as U-stirrups, which are anchored to the slab lower surface. The anchorage length of straight rebars is not usually long enough. ATP ALP-L A qt 2. The bolt requires stirrup reinforcement Aqt in the top of the foundation column to transfer shear forces, see figure 8. A vt 3. Stirrups Avt for taking splitting forces should be placed above the stud heads according to figure 8. Ordinary stirrup reinforcement should be added to this stirrup area. Fig. 8. Placing ATP or ALP-L bolts in a foundation column Table 8. Splitting stirrups Avt for short bolts and additional stirrups Ast for long bolts Bolt ATP16 ATP20 ATP24 ATP30 ATP39 Splitting stirrups Avt example 19 mm² 1T8 29 mm² 1T8 40 mm² 1T8 67 mm² 2T8 111 mm² 3T8 AHP16 AHP20 AHP24 AHP30 AHP39 Additional stirrups Ast example 70 mm² 2T8 110 mm² 3T6 160 mm² 4T8 250 mm² 5T8 400 mm² 5T10 ALP22L ALP27L ALP30L ALP36L ALP39L ALP45L ALP52L ALP60L 51 mm² 76 mm² 88 mm² 135 mm² 161 mm² 216 mm² 290 mm² 386 mm² ALP22P ALP27P ALP30P ALP36P ALP39P ALP45P ALP52P ALP60P 60 mm² 101 mm² 101 mm² 101 mm² 157 mm² 157 mm² 245 mm² 402 mm² 1T8 2T8 2T8 3T8 4T8 6T8 6T8 5T10 Bolt 2T8 3T8 3T8 3T8 4T8 4T8 5T8 6T10 4.4.5 Placing rebar bolts in a foundation column AHP and ALP-P anchor bolts can be placed in foundation columns where there is enough height. Tension forces acting in the bolts are transferred to the foundation with main rebars, which are anchored to lower surface of foundation. The reinforcement is placed in the following way, see figure 9. AHP: The anchorage length of the AHP bolts have been determined so, that straight rebars with same size placed in the column corners transfer the bolt loads. ALP-P: ALP-P bolts are anchored for full tension force with rebars of the same size as in the bolt. If rebars with larger diameters than the bolt anchor bars are used the lap length should be checked. page 12 Anchor bolts Instructions for use ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi To transfer bolt shear forces a stirrup reinforcement Aqt should be placed in top of the foundation column. Aqt + Ast ALP-P Addition stirrups Ast should be placed in the lap ends, see table 8. Ast Fig. 9. Placing ALP-P bolts in a foundation column 4.4.6 Placing AMP bolts in a column AMP anchor bolts have been designed for moment stiff connection between precast beam and column. The rectangular anchor plate transfers compression loads to the concrete on front side of the column. The stud heads transfer tension loads to the opposite side. The longer side of the anchor plate is placed vertically in the column, this way the bolt can be placed close to the column edge. H B Reinforcement for shear forces Tension zone A E L D F K F ET Compression zone Fig. 10. Placing AMP bolts in a column Table 9. Minimum bolt distances in a rigid column-to-beam connection Bolt AET36 AMP36 AMP39 AMP45 AMP52 AMP60 A F L D K E ET H B = = = = = = = = = A mm 100 100 110 110 110 110 F mm 90 90 100 110 130 130 L mm 710 670 680 800 930 1490 D mm 540 500 500 605 700 1220 K mm 170 180 180 195 230 270 E mm 50 50 60 60 60 70 Bolt distance from bracket Minimum edge distance to column side Total length Embedment length into column Length of visible thread Distance from surface of beam assembly plates Minimum concrete cover for stud head Minimum rectangular column height Minimum rectangular column width ET mm 40 80 70 70 70 100 Hmin mm 580 580 580 680 780 1380 Bmin mm 380 380 480 480 580 580 ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi 4.5 page 13 Anchor bolts Instructions for use Additional clauses for T40 rebar The bolt AHP39 based on rebar T40 concrete bond can be used in following conditions (EC2 chapter 8.8): 1. Use bundled rebars 2T32 or 3T25 in lap joints or consider a lower stress level. 2. Stirrups are always used as confining reinforcement 3. Additional reinforcement and crack control must be considered in each case. 4.6 Correction of capacity values 4.6.1 Change of concrete strength The capacity values of the anchor bolts can be corrected in relation to concrete grade in the following way: Normal force capacity For lower concrete grade C20/25 the capacities should be corrected by multiplying with 0,83. Instead of reducing capacities for AHP bolts with Lmin you can choose a longer stock size bolt, e.g. AHP24-2000. Shear force capacity Bolt shear force capacities can be modified for both lower and higher concrete grades than C25/30 with correction factor n: n = fck / 25 where fck is the characteristic compressive cylinder strength for concrete used 4.6.2 Small edge distance If ATP, ALP-L and AMP bolts are placed closer to the structure’s edge than required in section 4.2, the bolt capacity values should be reduced in the following manner. Normal force With minimum edge distance the bolt normal force capacity is taken as 100. When bolt centre is at the edge of the structure this value is 0. Any values in between can be linearly interpolated. The bolt may not be placed closer to edge than concrete cover required for stud head. Shear force The use of full bolt shear capacity requires a minimum edge distance 10*Ø. If a smaller edge distance is used, all shear forces should be transferred to concrete by stirrups. With adequate reinforcement there is no need to reduce the bolt shear capacity. 4.6.3 Small centre to centre distance If ATP, ALP-L and AMP bolts are placed closer to each other than the required minimum centre to centre distance, the bolt capacity values should be reduced in the following manner: Normal force With minimum distance from each other the combined tension capacity is taken as 100. When the bolt centres overlap this value is 50. Any values in between can be linearly interpolated. Shear force There is no need for correction. All shear forces are anchored with stirrup reinforcement. ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi page 14 Anchor bolts Instructions for use 4.6.4 Durability and concrete cover The durability of the concrete joint with anchor bolt and steel shoe is designed according to EC2 chapter 4. The same exposure class is chosen for joint as for column and foundation structure if there is no special need to use a higher class. Check structural fire design when needed. Concrete cover of anchors The nominal concrete cover of anchor bars and anchor plates are determined according to exposure class related to environmental conditions. Concrete cover of threads The concrete cover and protection of threaded part including nuts and washers is determined according to exposure class: Exposure class X0 - In dry and warm conditions visible steel parts are painted if they can be maintained later. - Without maintainability the steel parts are covered with a required concrete cover. Exposure classes XC1 and XC3 - All bolt parts are covered with a required concrete layer and the leakage of water into the connection is prevented by structural solutions. - In cold and humid conditions bolts are hot-dip galvanized. Exposure classes XC2, XD4, XD, XS and XF - The use of anchor bolts in these environmental conditions should always be checked. The steel parts must in all circumstances be covered with a non cracking concrete layer. The leakage of water into the connection has to be prevented by structural solutions. 5 INSTALLATION 5.1 Forming a bolt group The anchor bolts are concreted into a bolt group by using an AAK assembly frame. With the frame it is easy to secure the right bolt positions, it also protects the threads during concrete casting. H A rectangular assembly frame with four bolts can be ordered by using product code AAK-MH*B, where M is thread size and H*B are bolt centre to centre distances. B Fig 11. AAK assembly frame ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi 5.2 page 15 Anchor bolts Instructions for use Bolt assembly and tolerances When using APK column shoes the anchor bolts should be assembled in the foundation concrete according to height levels given in figure 12 and table 10. Also in other applications the bolt height levels may not differ more than the allowable tolerance, so that full bolt capacities can be used. Table 10. Bolt height levels with APK steel shoes Bolt size AHP16 AHP20 AHP24 AHP30 AHP39 ALP22 ALP27 ALP30 ALP36 ALP39 ALP45 ALP52 ALP60 corresponding column shoe APK16 APK20 APK24 APK30 AK39 APK24 APK30 APK33 APK36 APK39 APK45 APK52 APK60 A mm 105 115 130 150 180 130 150 170 170 180 195 230 260 G mm 50 50 50 50 60 50 50 50 60 60 70 80 80 Fig 12. Bolt height level torque Nm 100 200 350 650 1000 200 350 650 800 1000 1500 2500 3500 A G A = Bolt height level from concrete E = Grouting thickness under column The bolts are cast into concrete with following tolerances: Height tolerance Maximum allowable bolt inclination Bolt hole clearance in column shoe M16-M30 M36-M60 ± 20 mm L/100 ± 5 mm ± 7 mm When assembly tolerances are exceeded please ask further instructions from project’s structural designer. 5.3 Bending and welding of bolts When needed, straight rebars can be bended at site (not the threaded part). When bending rebars the requirements concerning bending radius and working temperatures should be followed. Lap lengths to main reinforcement should be checked for the bent bolt. It is recommended that no load carrying fixings are welded to the rebars without consulting the structural designer. 5.4 Column installation Column installation is started by levelling the upper surface of lower washers to correspond to the planned bottom level of the precast column. The column is lifted to its place and the upper nuts are tightened. The column is levelled into an upright position by adjusting the bolt nuts. The nut housings have been designed for DIN 7444 slugging wrenches. Tightening torque values are given in table 11. The values correspond to 40 % of rebar and 20 % of high strength steel bar yield strength. The bolts are locked with double nut or by breaking the thread above the nut. The given torque is not enough for cyclic compressiontension loaded bolts. ANSTAR OY, Erstantie 2, FIN-15540 Villähde Tel. +358-(0)3-872 200, Fax +358-(03)-872 2020 www.anstar.fi anstar@anstar.fi page 16 Anchor bolts Instructions for use The grouting of the column shoe and the nut housings is done according to grout manufacturer’s instructions. The grout concrete should be non-shrinking and correspond to the column concrete strength. 5.5 Safety precautions The anchor bolt threads are to be protected during and after concrete casting. The bolts may not be loaded before the concrete has achieved its design strength if the plans do not specify anything else. When installing columns the working order and the assembly supporting plan should be followed. Grouting of the connection should be done according to the installation schedule and the grouting concrete should reach the planned strength before upper structures can be assembled onto the column. 5.6 Installation control 5.6.1 Instructions for bolt assembly Before casting ensure that bolt and frame according to plan (type, dimensions) are used and that steel parts are not damaged ensure that the bolt group position in the formwork corresponds to given tolerances ensure that bolt height level corresponds to given tolerances ensure that the additional reinforcement has been installed see that the bolt group is tightly fixed to formwork see that the bolt threads are protected until column installation. After casting check that bolt positions are in accordance with given tolerances write a measurement report. 5.6.2 Instructions for column installation The column erection is done according to designer’s installation plan. The assembly controller should check the following: installation order supports and bracings during installation tightening of nuts joint grouting schedule and grouting instructions