LPI ® Direct Strike Products GuardianTM System 5 22 LPI® Guardian System 5 Key Benefits • • • • Blunt finial tip which minimizes corona effect. 4 electrically isolated panels. High Voltage connection at the base. Triggering procedure allows the initiation of an intercepting streamer. Product Description LPI® offers a family of air terminals and accessories. Our product design is based on the most recent advances in lightning research whilst maintaining proven principles associated with the successes of the past. LPI® Guardian System 5 provides a purpose-designed package for direct lightning protection. The Guardian System 5 has been tested in compliance to IEC Test Standard: IEC 60-1:1989. 1. 2. 3. 4. 5. A Family of LPI® CAT (Controlled Advanced Triggering) series air terminals. A Fibreglass Reinforced Plastic (FRP) mast. A purpose-designed High Voltage Shielded Cable (HVSC). A lightning strike recorder (LSR). An earthing system which consists of Earth rods, Clamps, Copper tapes and Ground resistance improvement powder (GRIP). CAT Principles 1. A Guardian CAT terminal consists of a grounded blunt lightning rod surrounded by an electrically floating medium. Rounded or blunt tips have proven to be more efficient than sharp points by producing minimal corona effect. This has been clearly proven in tests conducted at South Baldy Peak in the Magdalena Mountains of central New Mexico, USA. (Source: “The Measurement of Lightning Rod Responses to Nearby Strikes” by C.B. Moore, G.D. Aulich, and W. Rison/ May 2001) 2. During the static thunderstorm phase when the electric fields are steady at around 5-15 kV/m and even in the very early stages of leader approach, the medium presents as a relatively low field intensification surface due to the blunt configuration of the finial tip. This restricts the production of “corona” or “point discharge” ions and is critical because excessive production of ions (corona) results in a “space charge cloud” above the air terminal which masks the electric field at the tip of the terminal when the leader eventually approaches within range. 3. The Guardian CAT terminal is comprised of four separate electrically isolated panels arranged to allow the section facing the step leader to rise in voltage due to a capacitive coupling effect. Because the CAT terminal is essentially isolated from the ground potential, the electric field increases as the discharge approaches closer to the panel facing the step leader. It then experiences repeated pulsing until this section (panel) rises in voltage to the point when a triggering arc is generated at precisely the right time, which in turn initiates the streamer, which connects with the approaching down leader. 4. This triggering arc creates two key effects. First it produces a large number of ions which are needed to initiate an upward leader. Secondly it causes a large snap change in the electric field immediately above the air terminal which provides the necessary “kick” for the inception of an early, stable, propagating upward leader. The initiation of such advanced triggering results in the approaching leader being intercepted earlier, which ensures a larger protective area around the Guardian CAT terminal. Commercial in Confidence Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 2 3 CATCALC Software Design LPI® uses a CAD based software design program “CATCALC” to customize a cost effective and safe lightning protection solution for any structure. The “CATCALC” program considers factors such as thunder days per year, height above sea level, level of protection desired/recommended (Standard - High - Very High), Physical dimensions of the structure and building materials used. Competing features (which have the ability to create streamer development) are taken into consideration during the design process. A customized “CATCALC” design will provide to the end customer a design report encompassing elevation, plan and side views of the proposed lightning protection installation along with a detailed bill of materials for all required accessories. Risk Assessment In accordance with Australian Standard (AS1768) all “CATCALC” designs are subjected to a site risk assessment to determine the perceived risk from a lightning strike. The risk assessment considers the following. Usage and contents of the structure(s) Construction materials of the structure(s) Height of the structure(s) Situation at site - Flat ground or elevated above sea level Average thunder days per annum • • • • • LPI® Product Range SECTION PAGE A 9, 10 B 11 LPI® UPPER TERMINATION KIT C 11 LPI® FRP SUPPORT MAST D 12 LPI® INLINE COUPLING E 12 LPI® GUY KIT F 13 LPI® GUY RING G 13 LPI® LOWER MAST ASSEMBLY H 13 LPI® SADDLES FOR CANTILEVERING MAST I 14 LPI® U-BOLT J 14 LPI® HIGH VOLTAGE SHIELDED CABLE K 14 LPI® CABLE TIES L 15 LPI® SADDLES AND FIXINGS M 15 LPI® BEAM CLAMP AND CABLE SUPPORT N 15 LPI® LIGHTNING STRIKE RECORDER O 16 LPI® LOWER TERMINATION KIT P 16, 17 Q 17 LPI® INSPECTION PIT R 18 LPI® GROUND RESISTANCE IMPROVEMENT POWDER Commercial in Confidence LPI PRODUCTS LPI® GUARDIANTM TERMINAL LPI® EARTHING SYSTEM Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 3 4 Installation Type 1 Installation type 1 illustrates a Guardian System 5 installed on a building roof top (flat roof). Please refer to page 19 for recommended earthing installation Commercial in Confidence Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 4 5 Installation Type 2 Installation type 2 illustrates a Guardian system 5 cantilevered to the side wall of a building. Please refer to page 19 for recommended earthing installation Commercial in Confidence Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 5 6 Installation Type 3 Installation type 3 illustrates a Guardian system 5 cantilevered to the top section of a tower. Please refer to page 19 for recommended earthing installation Commercial in Confidence Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 6 7 Installation Type 4 Installation type 4 illustrates a Guardian system 5 installed on a building roof top (flat roof) or at ground level. Note: Multiple guying kits are utilized due to increased mast height. Please refer to page 19 for recommended earthing installation Commercial in Confidence Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 7 8 Installation Type 5 Installation type 5 illustrates typical mounting arrangement for cantilevered GI style CAT Terminal. Please refer to page 19 for recommended earthing installation Commercial in Confidence Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 8 9 Section A LPI® Guardian CAT Terminals (Gold) LPI®’s range of Guardian CAT Terminals are Controlled Advanced Triggering devices which intercept lightning discharges and attaches them to a preferred point. The CAT Terminal has been designed to emit a “streamer” of energy at precisely the right time so that an approaching “leader” is intercepted and brought under control. All Guardian CAT Terminals have been tested in compliance to IEC test standard: IEC 60-1:1989. Ordering Code Description: Sphere Dimensions: Panel Material: CAT I - G CAT IGI - G Guardian CAT Terminal, Gold, Model I 106mm (Diameter), 140mm (Height) Anodised Aluminium Terminal Colour: Gold Weight: 1.65kg Operation: Insulation Material: Down Conductor Connection: Spark Gap UV Rated Evoprene Lug connection GI connector Recommended for low risk structures which do not exceed 30 metres in height. Ordering Code Description: Sphere Dimensions: Panel Material: CAT II - G Guardian CAT Terminal, Gold, Model II 160mm (Diameter), 210mm (Height) Anodised Aluminium Terminal Colour: Gold Weight: 2.35kg Operation: Insulation Material: Down Conductor Connection: CAT IIGI - G Spark Gap UV Rated Evoprene Lug connection GI connector Recommended for low to medium risk structures which do not exceed 100 metres in height. Ordering Code Description: Sphere Dimensions: Panel Material: CAT III - G CAT IIIGI - G Guardian CAT Terminal, Gold, Model III 210mm (Diameter), 280mm (Height) Anodised Aluminium Terminal Colour: Gold Weight: 3.5kg Operation: Insulation Material: Down Conductor Connection: Spark Gap UV Rated Evoprene Lug connection GI connector Recommended for all high risk environments including structures exceeding 100 metres in height. Commercial in Confidence Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 9 10 ® LPI Guardian CAT Terminals (Stainless Steel) LPI®’s range of Guardian CAT Terminals are Controlled Advanced Triggering devices which intercept lightning discharges and attaches them to a preferred point. The CAT Terminal has been designed to emit a “streamer” of energy at precisely the right time so that an approaching “leader” is intercepted and brought under control. All Guardian CAT Terminals have been tested in compliance to IEC test standard: IEC 601:1989. Ordering Code Description: Sphere Dimensions: CAT I - SS CAT I - SS - GI Guardian CAT Terminal, Stainless Steel, Model I 106mm (Diameter), 140mm (Height) Panel Material: Stainless Steel Terminal Colour: Silver Weight: 1.78kg Operation: Insulation Material: Down Conductor Connection: Spark Gap UV Rated Evoprene Lug connection GI connector Recommended for low risk structures which do not exceed 30 metres in height. Ordering Code Description: Sphere Dimensions: Panel Material: CAT II - SS CAT II - SS - GI Guardian CAT Terminal, Stainless Steel, Model II 160mm (Diameter), 210mm (Height) Stainless Steel Terminal Colour: Silver Weight: 2.5kg Operation: Insulation Material: Down Conductor Connection: Spark Gap UV Rated Evoprene Lug connection GI connector Recommended for low to medium risk structures which do not exceed 100 metres in height. Commercial in Confidence Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 10 11 Section B ® LPI Upper Termination Kit LPI®‘s Upper Termination Kit is designed for use with the LPI HVSC down-conductor. The LPI High Voltage Shielded Cable is an insulated downconductor used to safely convey lightning currents from an air terminal to a dedicated lightning earth termination, while avoiding galvanic conduction to the structure being protected. The Upper Termination Kit provides all accessories for the High Voltage termination of the HVSC downconductor to the Guardian CAT Terminal. The LPI® UTERMKIT-MK2 has been tested in compliance with IEC 600601, 2nd Edition, 1989-11. Ordering Code Description: Maximum Voltage: Operating Temperatures: Pack Dimensions: UTERMKIT-MK2 Upper Termination Kit Mark 2 280kV 1.2/50µs impulse - 20°C to + 85°C 70mm x 70mm x 1250mm Weight: 0.75kg Contents: Instruction, Semi-conducting tape, Crimp Lug, Heat Shrink Tube, Insulated Friction Cutting Tool, Insulation Tape Section C LPI® FRP Support Mast LPI®‘s Fibreglass reinforced pole (FRP) mast is an insulated and water resistant mounting pole which is designed to provide the necessary electrical isolation and mounting strength at the position where the high voltage upper termination between the High Voltage Shielded Cable (HVSC) downconductor and LPI CAT terminal is completed. Description Fibreglass Reinforced Pole (FRP) Colour: Black Material : Fibreglass Construction Type: Pre-Impregnated Reinforced Epoxy Resin Laminate (Flame Retardant) Resin Tensile Strength: 70 MPa Resin Tensile Modulus: 2.9 GPa Resin Tensile Strain: 2.7% Resin Poisson Ratio: 0.35 Ordering Code Weight Dimensions FRP-2M 2.7kg Length 2000mm, Outer diameter 68mm, Inner diameter 60mm FRP-3M 4.0kg Length 3000mm, Outer diameter 68mm, Inner diameter 60mm FRP-4M 5.3kg Length 4000mm, Outer diameter 68mm, Inner diameter 60mm FRP-4.6M 6.2kg Length 4600mm, Outer diameter 68mm, Inner diameter 60mm Commercial in Confidence Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 11 12 Section D LPI® Inline Coupling LPI®’s Inline Coupling is a purpose designed coupling which allows for the clamping of the FRP mast to the Aluminium lower mast. The inline coupling provides 3 Guy anchoring points and provides an exit point for the HVSC. Ordering code ILCOUPLING Description: Inline Coupling Material: Cast Aluminium Dimension: 550mm x 150mm x 120 mm Weight: 2.5 kg Anchoring Points: 3 Max. Clamping Torque: 55kg/cm Section E LPI® Guy Kit LPI®‘s non conductive guy kits are provided in variable lengths to suit specific mast and terminal heights. The purpose designed guying kits are designed for anchoring from a guy ring or an inline coupling. Ordering Code GUYKIT-4M Description: Stainless Steel fittings and non conductive synthetic guy wire kits Material: PVC coated, fibre glass core, non conductive, UV stabilised, stretch proof, corrosion and ice proof synthetic Application: Designed to provide additional stabilizing/securing of mast arrangement where deemed necessary Diameter: 4mm Tensile yield strength: 560kg Weight: Ordering Code 0.5kg 0.8kg GUYKIT-4M-SS GUYKIT-7M-SS Description: Stainless Steel guy wire kits Material: Stainless Steel, Grade 316 Application: Designed to provide additional stabilizing/securing of mast arrangement from the inline coupling only Diameter: 3.2mm Tensile yield strength: 450kg Weight: Commercial in Confidence GUYKIT-7M Document: 36 TD Guardian.pub 0.75kg Version: 2.07 19/12/2008 1.2kg Copyright 2008 LPI 12 13 Section F Guy Ring LPI®‘s Guy Ring provides 3 guy points for mounting between the top section of the FRP mast and the Guardian CAT Terminal. Ordering Code Guy Ring Ordering Code: Guy Ring Material: Cast Aluminium Dimension: 110mm x 110mm x 10 mm Weight: 0.12kg Guy Hole Diameter: 10mm Section G LPI® Lower Mast Assembly LPI®’s uses Aluminium Mast as the lower mast assembly due to it’s high strength and light weight characteristics. Description Aluminium Mast Colour: Silver Material: Aluminium Inside Diameter: 61.9mm Outside Diameter: 69.9mm Length 3 Metre 4 Metre 5 Metre 6 Metre Weight: 7kg, 8kg (with base) 9kg, 10kg (with base) 11.7kg, 12.7kg (with base) 14.4kg, 15.4kg (with base) Normal: ALUM-3M ALUM-4M ALUM-5M ALUM-6M With Base: ALUMB-3M ALUMB-4M ALUMB-5M ALUMB-6M With GI Male Adaptor: ALUM3M-MGI ALUMB4M-MGI ALUMB5M-MGI ALUMB6M-MGI Section H LPI® Cantilevering Saddles Purpose designed stainless steel saddles for cantilevering Aluminium mast of 69.9mm outer diameter to flat vertical surface. Ordering Code Description: CANTSAD 70mm Saddles for mounting of Aluminium Mast (3 per set) Material: Stainless Steel Weight: 180g per saddle, 540g per set Dimension: Hole Fixing Diameter: Commercial in Confidence Document: 36 TD Guardian.pub 130mm (L) x 70mm (W) x1.2mm (D) 8mm Version: 2.07 19/12/2008 Copyright 2008 LPI 13 14 Section I LPI® U-Bolt LPI®’s U-Bolt set is specifically designed to allow for the secure clamping of aluminium or FRP mast to tower section or handle rail. Ordering Code U-Bolt Description: U-Bolt, 2 per set Material: U-bolt:Stainless Steel, Plate:Aluminium Weight: 375g per U-bolt, 750g per set Dimension: 80mm Diameter, 170mm Length Section J LPI® High Voltage Shielded Cable LPI®‘s High Voltage Shielded Cable (HVSC) is a high integrity low impedance cable, which is designed to convey lightning energy to ground with minimal risk of side flashing or structure electrification. The design of the HVSC incorporates carefully selected dielectric components to ensure optimum performance under high impulse conditions. This design provides a low inductance per unit length with low surge impedance. The LPI®‘s HVSC has been tested in compliance to IEC test standard: IEC 60-1:1989 and IEC 600601, 2nd Edition,1989-11. Ordering Code HVSC-PM or HVSC-500M Description: High Voltage Shielded Cable Nominal cross sectional area 50mm2 Concentric conductor: Sheath Thickness: 3.3mm +/-0.3mm Overall Diameter: 37mm +/-0.8mm Weight of Cable: 2.050 kg per metre DC Resistance of conductor at 20ºC: Max. 0.387 Ohm/km DC Resistance of screen at 20ºC: Max. 0.492 Ohm/km Insulation resistance at 20ºC: Min. 1,830 M Ohm-km Maximum Voltage: 280kV 1.2/50µs impulse Section K LPI® Cable Ties LPI®‘s Cable Ties are designed for securing the HVSC downconductor to structures and mast assembly. Ordering Code SS-CABTIE-STD Description: Cable Ties Material: Commercial in Confidence SS-CABTIES-L Stainless Steel Length: 360mm 520mm Width: 7.9mm 7.9mm Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 14 15 Section L LPI® Saddles and Fixings LPI®‘s Saddles and fixings are specifically designed for securing of HVSC downconductor to structures. Ordering Code SAD FIX Description: Saddles and Fixings Material: Stainless Steel, Grade 304 Dimension: 90mm Length, 1.2mm Thickness Fixing hole diameter: 7mm Weight: 25g Section M LPI® Beam Clamp and Cable Support LPI® Beam Clamp and Cable Support are specifically designed for the securing of the HVSC downconductor to tower legs. Ordering Code BEAM CLAMP / CABLE SUPPORT - HVSC Description: Beam Clamp and Cable Support Material: Stainless steel, Polymer Dimension: 60mm x 60mm x 50mm Fixing hole diameter: 38mm Weight: 180g Section N LPI® Lightning Strike Recorder LPI®‘s Lightning Strike Recorder (LSR1) is a lightning strike counter. The LSR1 is simply mounted at any location along the downconductor route. It’s purpose is to record the number of strikes captured by the lightning terminal and conveyed by the downconductor. Ordering Code LSR1 Description: Lightning Strike Recorder Current sensitivity: 1500A 8/20µs impulse Operating range: Min. 1500A and Max. 220kA 8/20µs Mechanical 6 digits display (not re-settable). Display: Dimension: 80mm (B) x 82mm (H) x 65mm (D) Weight: Mounting: 0.4 kg Adjustable stainless steel cable ties to accommodate a cable up to 40 mm dia. cable or 50mm x 5mm flat tape Construction: Colour: Environment: Operating Temperature: Commercial in Confidence Document: 36 TD Guardian.pub Polycarbonate enclosure Light Grey IP 67 (IEC 529) -15C to 65C Version: 2.07 19/12/2008 Copyright 2008 LPI 15 16 Section O LPI® Lower Termination Kit LPI®‘s Lower Termination Kit provides accessories and tools for the termination of the HVSC lower end to the dedicated lightning earth. Ordering Code Description: Pack Dimensions: Weight: Contents: LTERMKIT Lower Termination Kit 270mm (B) x 100mm (H) x 40mm (D) 585g 1 x 95mm crimp lug 1 x waterproofing tape 1 x earth rod clamp 2 x warning labels 1 x insulation friction cutting tool Section P LPI® Threaded Copper bonded Earth Rods LPI® ’s Copper bonded earth rods are made from high tensile low carbon steel and each rod is manufactured by molecularly bonding 99.9% pure electrolytic copper to the low carbon steel core in accordance with national and international standards such as BS6651, BS7430 and UL467. Threads are rolled onto the rod ensuring an even copper covering which eliminates the risk of chipping whilst driving. Ordering Code Description: CBER458 Threaded Copper bonded Earth Rod Material: Carbon steel bonded with Copper Length: 1.219m Rod Diameter (Actual): 14.3mm Threaded Diameter: Weight: 5/8” 1.54kg LPI® Coupling for threaded earth rod Whether connecting rod to rod or driving stud to rod the high strength copper alloy coupling is counter bored to protect the earth threads from damage and subsequent corrosion. Ordering Code Description: Material: Commercial in Confidence LEH-58R Coupling for Threaded Earth Rod 5/8” High strength copper alloy Thread type: 5/8” Weight: 130g Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 16 17 LPI® Copper Tape LPI®‘s 25mm x 3mm soft drawn copper tape is manufactured using the latest European developed extrusion technologies. LPI’s CT253 is a high quality tape which provides our customers with a guaranteed copper purity of 99.95%.Flat copper tape in comparison to stranded copper cable is considered as the most efficient conductor for the transfer of lightning energy to the ground mass. Flat tape provides greater surface contact with the surrounding soil which assists greatly in the dissipation of the lightning energy. Ordering Code Description: CT253 Copper Tape 25mm x 3mm (Soft Drawn) Material: Dimension: 99.95% Copper 25.00mm (Width) x 3.00mm (Thickness) Weight: Electrical Conductivity: 0.67kg per metre Minimum 100% I.A.C.S Standard: BS1432 Tensile Strength: Package: 210 - 250 N/mm² Supplied in pancake coil form (50m per coil) LPI® Rod to Tape Clamp Type A LPI®‘s Rod to Tape Clamp provides a conductive and mechanically secure connection when installing a lightning protection earth encompassing flat copper tape and copperbonded earth rods. RTC1625A Ordering Code Description: Material: Rod to Tape Clamp “Type A” to suit 5/8”mm Dia rod & 25 x 3mm tape Gun Metal/ High strength copper alloy Rod Diameter: 5/8” or 16mm Conductor size: 25 x 3mm Weight: 150g Section Q LPI® Inspection Pits LPI®‘s Inspection Pits provide a secure and user friendly access point for maintenance purposes and the periodical measuring of electrical resistance of a buried earthing system. In order to complete routine measurements of electrical resistance simply remove the lid from the installed earth pit and connect a lead from the resistance meter to the earthing conductor. Ordering Code Description: Material: Dimension: Weight: Strength: Commercial in Confidence Document: 36 TD Guardian.pub EPIT-P EPIT-C Polymer Earth Pit Concrete Earth Pit Polymer Concrete 250mm (top) x 180mm (base) x 210mm (deep) 320mm (length) x 320mm (width) x 200mm (deep) 1.9kg 32kg Withstand up to 5 tonnes Withstand 4.5 tonnes Version: 2.07 19/12/2008 Copyright 2008 LPI 17 18 Section R LPI® Ground Resistance Improvement Powder LPI®’s Ground Resistance Improvement Powder (GRIP) is a premium product designed to dramatically reduce soil resistivity in the poorest soil conditions. When GRIP is mixed with water and poured onto the earthing system and surrounding soil, the powder and water react to form a gelatinous mass which will not reduce, contract or separate from the surrounding earthing system. Ordering Code GRIP-10 Description: Ground Resistance Improvement Powder Application: To assist in achieving a DC ground resistance of less than 10 Ohm and impedance of less than 30 Ohms. Weight: GRIP-40 Part A = 5kg Part B = 5kg Part A = 20kg Part B = 20kg LPI® Chemical Ground Rod LPI’s Chemical Ground Rod provides a low impedance earth to effectively dissipate lightning and electrical fault currents. The Chemical ground rod is ideal in situations where space is restricted and normal lightning earths such as radial and grid type systems cannot be installed. Ordering Code Length: CHEMROD-2M CHEMROD-3M 2m 3m Diameter: 63.5mm Copper Composition: 99.9% minimum Standard: Australian Standard AS1432 Melting Point: 1083ºC Specific Heat Capacity: 0.385kJ (kg.K) Electrical Conductivity (Annealed): 75-90% I.A.C.S. Wall Thickness: 1.6mm Copper: Hard-drawn Cap: Drainage Holes: Mineral Salts: Pigtail: Commercial in Confidence Removable type with air breather holes 4.5mm Diameter, provided every 40cm for the length of the rod Pre-filled from factory with non-hazardous natural electrolytic salts 70mm Stranded Copper Cable, Pre-welded from factory to allow for connection to earthing system Weight: 12kg (CHEMROD) 40kg (RESLO) Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 17kg (CHEMROD) 60kg (RESLO) Copyright 2008 LPI 18 Recommended Earthing Installation This type of radial earth is recommended for installation as a lightning protection earth. ISO 9001 Certificate Lightning Protection International Pty Ltd operates a certified management system that complies with the requirements of AS/NZS ISO9001:2000. The scope of certification encompasses the design, manufacture, assembly, sales, installation and commissioning of lightning and surge protection equipment and earthing material. Commercial in Confidence Document: 36 TD Guardian.pub Version: 2.07 19/12/2008 Copyright 2008 LPI 19