Impedance/Frequency Response Analyser Cypher Instruments have developed the C60, a low cost, portable scientific test and measurement device. This unit measures the Amplitude, Phase and Impedance responses of electronic, electro-acoustic and other systems. The tests are controlled by a PC and the results are displayed as graphs. Applications and uses • • • • • • • Example graphs Professional / consumer audio Ultrasonic products Electro-acoustic transducer design Component evaluation Research and development, education Production testing and quality control Field service and maintenance Elliptic low pass filters 10KHz Features 20KHz 70KHz • Measure amplitude, complex impedance and phase 0 -10 Amplitude Gain - dB -20 -30 -40 -50 -60 -70 -80 101 102 103 104 Frequency - Hz 105 106 Produced by Cypher Instruments USB cable impedance Open small Modulus of Impedance - Ohms 10 4 Shorted small Open Shorted 10 3 10 2 • • • • • • responses from 10Hz to 4MHz Frequency axis displayed logarithmically or linearly Amplitude measured as gain or loss displayed in dBs Phase display ranges of 0° to 180° or ± 180° Display impedance in Ohms or admittance in Siemens Professional graphs with 10 plots per graph Intuitive powerful graphing program Save graphs as data files and jpg, bmp and meta files Export data as ASCII text for MathWorks MATLAB, GNU Gnuplot and Microsoft Excel Copy and paste plots from one graph to another Automate testing procedures with test scripts Pass / Fail testing using graphical masks Small, light weight, portable, USB powered device Firmware Upgradeable Affordable Product description 10 1 10 0 0.5M 1.0M 1.5M 2.0M Frequency - Hz 2.5M 3.0M 3.5M Produced by Cypher Instruments Five inductors with 10uH marking 10 2 Modulus of Impedance - Ohms • • • • • • • • 10 1 10 0 10 -1 10 -2 101 102 103 104 Frequency - Hz Produced by Cypher Instruments C60 brochure 26/01/06 105 106 The C60 investigates the opaque world of analog networks. The unit operates in two test modes. It can measure the frequency response of a two port system producing a gain/loss and phase graph. It can also measure the reactive response of a two terminal network producing an impedance/admittance and phase graph. Electronic, electrical, electro-acoustic and other networks can be tested with sine wave excitation and the results displayed on a PC. The C60 is USB powered; it needs no batteries or external power supplies, making it portable. The unit has a USB connector at the rear, an input and output BNC and a USB Link/activity LED. All the functionality of the device is controlled by the PC through an easy to use interface. A scripting language and digital control outputs are provided for test automation. www.cypherinstruments.co.uk Example graphs C60 - Specifications Modulus of Impedance - Ohms 455KHz resonator, complex impedance DDS Sine wave generator/output 10 5 10 4 10 3 10 2 10 1 10 0 150 Phase - Degrees 100 50 0 -50 -100 4.2*105 4.3*105 4.4*105 4.5*105 4.6*105 Frequency - Hz Produced by Cypher Instruments 4.7*105 4.8*105 Frequency range of sine wave generator = 10Hz to 4MHz DDS sine wave generator Sine wave quality = 62dB SNAD (nominal) Output voltage = 2Vpp maximum Output attenuator, 0dB to -20.0dB in 2.5dB steps DC offset at output = 0.9mV typical Output impedance = 50 Ohms + parasitics of 23nH and 33pF (Z mode) Frequency accuracy at 1MHz it is ±100ppm BNC output connector ***** Destructive/Absolute Maximum Limits ***** Absolute maximum current applied to output = 0.2Arms Absolute maximum voltage applied to output = 9VDC or 22VppAC Capacitors 10nF 10 6 1nF 100nF 1uF 100pF 10uF 100uF 470uF Modulus of Impedance - Ohms 10 5 10 4 10 3 10 2 10 1 10 0 Input channel Input impedance = 1M ohm in parallel with 14.5pF AC coupled input (0.15Hz HP) Maximum signal input = 3.5Vpp maximum before compression (+5dB) Minimum input signal = 100uVpp (-86dB) with Rsource = 50R Noise floor = -86dB at 1MHz/input S/C; -73dB at 1MHz/input O/C BNC input connector Absolute maximum voltage applied to input = 50VDC or 50VppAC Other hardware features 10 -1 10 -2 101 102 103 104 Frequency - Hz Produced by Cypher Instruments Active Crossover 105 106 USB connection for data and power, USB 2.0 full speed (12Mbps) Mode LED indicating Power and USB activity Current consumption = 100mA to 220mA depending on activity Power consumption = 0.5Watt to 1.1Watt depending on activity Amplitude Gain - dB 0 Size and weight -10 -20 148mm x 132mm x 43mm, 420g -30 -40 Software -50 Advanced graphing program used to display test results Maximum number of test points = 1000 per plot, 2 parameters per plot Multiple plots; 10 plots per graph, with user text fields Logarithmic and linear frequency sweep and stationary frequency Logarithmic and linear frequency axis User controllable test settling time User selectable range of frequency points Logarithmic (dB) Gain/Loss amplitude display Amplitude display range = +5dB to –86dB (0.025dB best resolution) Amplitude detector straight line deviation = ±0.35dB Linear phase accuracy = see user manual graphs Phase range = ±180o and 0o to -180o |Z| The modulus of the impedance of the test device (DUT) Impedance accuracy = from ±0.5% to ±4.5% deviation (see user manual) Impedance displayed in Ohms or Admittance in Siemens (log & linear) Impedance display range of 0.01 Ohms to 1M Ohm (450K Ohm) Auto ranging or fixed Impedance and Gain axes Save/Recall as GAD and GZD files Save graphs as JPEG images, BMP images, Meta files and data files Use graphs in documents and emails Graphing Controls; START, STOP, REPEAT, ZOOM, UNDO ZOOM, FULL SCREEN, USER TEXT FIELDS, FREQUENCY LIMITS, SWEEP BACKWARDS, ALTERNATE SWEEP, SWEEP TO ZOOM EXTENTS, PEN COLOURS, PEN LOCK, GRAPH SELECTION COLOUR/BLACK/BLACK PLUS MARKERS, COPY, CUT, PASTE Calibration option for internal amplitude and phase trims Multiple document interface Scripting control of the unit -60 150 Phase - Degrees 100 50 0 -50 -100 -150 101 102 103 Frequency - Hz 104 Produced by Cypher Instruments Two transduceder response Amplitude Gain - dB -10 -20 -30 -40 -50 -60 150 Phase - Degrees 100 50 0 -50 -100 -150 104 105 Frequency (Hz) Cypher Instruments Digital Audio Produced latencyby (21/3380) / 2 = 3.1065mS Amplitude Gain - dB -10 -20 -30 -40 -50 150 Minimum PC specification Phase - Degrees 100 Operating systems, Microsoft Windows 98SE, ME, 2000, or XP Pentium II 333MHz 64MB RAM, 50MB HDD, Keyboard, mouse and USB Recommended minimum graphics resolution of 1024 by 768 50 0 -50 -100 -150 0.0001M 0.0002M 0.0003M 0.0004M 0.0005M 0.0006M Frequency - Hz 0.0007M 0.0008M 0.0009M Produced by Cypher Instruments C60 brochure 26/01/06 www.cypherinstruments.co.uk