Speedline Partitioning Systems - Stud and Track

advertisement
Partitioning Systems
Partitioning Systems Stud & Track
Stud & Track
An economical friction-fit system to assemble frames for strong, compact, lightweight non load-bearing partitions, our metal stud partitioning
is ideal for use in domestic and commercial situations, for heights up to 10.2m and a wide range of partition thicknesses.
When installing it you should ensure that electrical cables that pass through floor or ceiling are protected by grommets when installing studs.
For speedy, accurate installation we recommend use of an electrically or battery operated screw gun.
Note: electrical wires should
be protected where passing
through framework
Track
C Stud
Snipped and
folded to form
header
Light Switch
Partition Brace
Benefits
• Quick to erect, lightweight and clean
• Metal Stud is dimensionally accurate and
will not twist or bow
• Range of stud widths – 48mm, 50mm,
60mm, 70mm, 92mm and 146mm to
meet different performance requirements
• Services are easy to install
• Acoustic insulation can easily be installed
to uprate sound insulation
• Easy to cut to length using tin snips
• Frames easily fit together
• Door frames simply formed
6
Partitioning Systems
Stud & Track
Speedline Track
Standard Track
Available in 50, 52, 62 or 72 wide
32mm Leg Track
32
Product
Code
PT50
PT52
PT62
PT72
Product
Code
PDT52
PDT62
PDT72
PDT94
PT148
Product Description
50mm Standard Track (25mm leg) x 0.5mm
52mm Standard Track (25mm leg) x 0.5mm
62mm Standard Track (25mm leg) x 0.5mm
72mm Standard Track (25mm leg) x 0.5mm
Product Description
52mm Track (32mm leg) x 0.5mm
62mm Track (32mm leg) x 0.5mm
72mm Track (32mm leg) x 0.5mm
94mm Track (32mm leg) x 0.5mm
148mm Track (32mm leg) x 0.5mm
Stock Lengths
Metre
3.000
3.000
3.000
3.000
Weight per
Length Kgs
1.13
1.15
1.25
1.41
Stock Lengths
Metre
3.000
3.000
3.000
3.000
3.000
Weight per
Length Kgs
1.32
1.42
1.55
1.81
2.40
Stock Lengths
Metre
3.000
3.000
3.000
3.000
3.000
Weight per
Length Kgs
1.74
1.86
1.98
2.16
2.83
Stock Lengths
Metre
3.000
3.000
3.000
Weight per
Length Kgs
3.43
3.79
4.68
Available in 52, 62, 72, 94 or 148 wide
Deep Track
50
Product
Code
PEDT52
PEDT62
PEDT72
PEDT94
PDT148
Product Description
52mm Deep Track (50mm leg) x 0.5mm
62mm Deep Track (50mm leg) x 0.5mm
72mm Deep Track (50mm leg) x 0.5mm
94mm Deep Track (50mm leg) x 0.5mm
148mm Deep Track (50mm leg) x 0.5mm
Partitioning Systems Stud & Track
25
Available in 52, 62, 72, 94 or 148 wide
Product
Code
PXDT72
PXDT94
PXDT148
Extra Deep Track
Product Description
72mm Extra Deep Track (70mm leg) x 0.7mm
94mm Extra Deep Track (70mm leg) x 0.7mm
148mm Extra Deep Track (70mm leg) x 0.7mm
70
Available in 72, 94 or 148 wide
7
Partitioning Systems
Stud & Track
Speedline Standard C Stud
Partitioning Systems Stud & Track
Service Holes
All C and I studs are manufactured with 3 service holes
to allow electrical cables and pipes to run through the
partition.
Product
Code
PS48
Service hole positions are:
Hole 1 – 300mm from end to centre of hole
Product Description
48mm C Stud x 0.5mm,
Flange dimensions 32/34mm
Hole 2 – 900mm from end to centre of hole
Hole 3 – 1500mm from end to centre of hole
All C Studs have rectangular service holes
32mm wide x 75mm long.
6.5
Standard C Stud
PS50
50mm C Stud x 0.5mm,
Flange dimensions 32/34mm
PS60
60mm C Stud x 0.5mm,
Flange dimensions 32/34mm
PS70
70mm C Stud x 0.5mm,
Flange dimensions 32/34mm
PS92
92mm C Stud x 0.5mm,
Flange dimensions 32/34mm
146mm C Stud x 0.5mm,
Flange dimensions 32/34mm
6.5
32
34
Available in 48, 50, 60, 70, 92 or 146 wide
PS146
6.5
Heavy Duty C Stud
6.5
32
Product
Code
PSHD70
PSHD146
Available in 70 or 146 wide
Product Description
70mm Heavy Duty C Stud x 0.7mm,
Flange dimensions 32/34mm
146mm Heavy Duty C Stud x 0.7mm,
Flange dimensions 32/34mm
38
Product
Code
PI50
Product Description
PI60
60mm I Stud x 0.6mm,
Flange dimensions 38mm
70mm I Stud x 0.7mm,
Flange dimensions 38mm
92mm I Stud x 0.9mm,
Flange dimensions 38mm
PI70
PI92
Available in 50, 60, 70, 92 or 146 wide
PI146
0.5
70
Partition Brace
50mm I Stud x 0.6mm,
Flange dimensions 38mm
146mm I Stud x 0.9mm,
Flange dimensions 38mm
8
Weight per
Length Kgs
2.82
3.29
4.32
5.04
Stock Lengths
Metre
2.700
3.000
3.600
3.600
4.200
3.600
4.200
3.600
5.000
6.000
3.600
5.000
6.000
Weight per
Length Kgs
2.01
2.24
2.69
2.82
3.30
3.56
4.15
5.18
7.19
8.63
6.40
8.89
10.66
Speedline Bracing Strap & Partition Brace
Product
Code
FS
Product Description
Flat Bracing Strip 70 x 0.5mm
Stock Lengths
Metre
2.400
Weight per
Length Kgs
0.66
PB
Partition Brace 70 x 10 x 0.7mm
2.400
1.08
NEW
Easier to use perforated Partition Brace
10
70
Stock Lengths
Metre
3.600
4.200
3.600
4.200
Speedline I Stud
I Stud
0.7
Weight per
Length Kgs
1.14
1.29
1.31
1.58
1.17
1.35
1.46
1.75
1.26
1.46
1.58
1.89
1.37
1.53
1.71
2.05
2.39
2.30
2.68
3.13
3.65
4.33
5.21
Speedline Heavy Duty C Stud (Rolled to Order)
34
Flat Bracing Strip
Stock Lengths
Metre
2.400
2.700
3.000
3.600
2.400
2.700
3.000
3.600
2.400
2.700
3.000
3.600
2.400
2.700
3.000
3.600
4.200
3.600
4.200
3.600
4.200
5.000
6.600
Partitioning Systems
Stud & Track
Spliced Studs
Overheight Partition
NEW Partition Brace PB24 – due to the unique
design of this product, the lips are simply
snipped out where the partition brace overlaps
the stud. Slots are pierced to allow for studs to
be erected at 400 or 600mm centres.
PB Partition Brace to provide
support for horizontal board
edges and fire protection*
Partitioning Systems Stud & Track
In order to extend them, single C Studs can
be easily spliced together. Be sure to overlap
the C Studs at least 600mm and fix them
together with steel pop rivets stud interlocking
tool or wafer head screws on both flanges.
* Must be used to support fire certification
C Studs with
min 600mm
overlap
Steel pop rivets
or wafer head
screws at 150mm
centres on
both flanges
Door Frame construction
showing timber lining for
domestic application
Boxed Studs
To create greater rigidity and height and
to provide support at doorways, C Studs
may be boxed together. To enable this
the bearing faces of the C Studs are
asymmetrical – 32mm and 34mm – simply
nest short and long faces alternately and
snap together.
Track
150mm
minimum
Track fixed horizontally
between studs
End stud fixed
to track
Timber sub frame
Track
Timber door frame
Studs fixed to
floor and ceiling
tracks
Door jamb details shown on Page 81
9
Partitioning Systems
Partitioning Systems Stud & Track
Maximum Height – Plasterboard Partitions
Maximum Height (metres)
Stud Centres
600crs
400crs
300crs
C Studs
Board Type
No of
Layers
50mm C Stud
Maximum Height (metres)
Stud Centres
600crs
400crs
300crs
I Studs
Board Type
No of
Layers
50mm I Stud
12.5mm
1
2.5
2.8
2.9
12.5mm
1
2.8
3.3
3.6
15.0mm
1
2.8
3.1
3.2
15.0mm
1
3.1
3.5
3.8
12.5mm
2
3.4
4.0
4.1
12.5mm
2
3.7
4.0
4.3
15.0mm
2
3.7
4.3
4.4
15.0mm
2
3.9
4.3
4.5
70mm C Stud
70mm I Stud
12.5mm
1
3.6
3.9
4.0
12.5mm
1
4.4
4.9
5.4
15.0mm
1
3.8
4.1
4.2
15.0mm
1
4.6
5.1
5.5
12.5mm
2
4.6
5.2
5.4
12.5mm
2
5.3
5.7
6.0
15.0mm
2
4.9
5.5
5.7
15.0mm
2
5.5
5.9
6.2
92mm C Stud
92mm I Stud
12.5mm
1
3.9
4.2
4.3
12.5mm
1
5.4
6.2
6.8
15.0mm
1
4.4
4.7
4.8
15.0mm
1
5.5
6.3
6.9
12.5mm
2
5.2
5.8
5.9
12.5mm
2
6.2
7.1
7.6
15.0mm
2
5.9
6.5
6.7
15.0mm
2
6.3
7.2
7.8
12.5mm
1
6.2
6.5
6.6
12.5mm
1
7.9
8.2
8.5
15.0mm
1
6.5
6.8
6.9
15.0mm
1
8.1
8.5
8.8
12.5mm
2
7.6
8.2
8.4
12.5mm
2
8.8
9.6
10.0
15.0mm
2
7.9
8.5
8.7
15.0mm
2
9.0
9.8
10.2
146mm C Stud
Maximum Height (metres)
Stud Centres
600crs
400crs
300crs
Heavy Duty C Studs
Board Type
146mm I Stud
No of
Layers
70mm Heavy Duty C Stud
12.5mm
1
4.0
4.4
4.6
15.0mm
1
4.2
4.6
4.8
12.5mm
2
4.8
5.3
5.6
15.0mm
2
5.3
5.5
5.9
12.5mm
1
6.6
7.2
7.5
15.0mm
1
6.9
7.5
7.8
12.5mm
2
8.2
8.6
9.0
15.0mm
2
8.5
9.0
9.2
146mm Heavy Duty C Stud
10
Maximum heights are calculated based on a limiting deflection
of L/240 at 200 Pascals.
For Non-Fire Rated Partitions or Fire Rated to
BS476 Part 22 only.
Partitioning Systems
Stud & Track – Product Performance Guide
Plasterboard Fixing Centres
General Points
All Acoustic test data is done in laboratory conditions, built at 600mm
centres and are measured as RwdB figures. The “on site “ conditions in
which the partition is to be built may have a significant effect on the test
figures quoted, and due to this it is unlikely that the RwdB figures quoted
from laboratory tests will be repeated in “on site” conditions. Deflection
head details can also negatively affect performance please contact local
branch for details. If stud centres are less than 600mm please contact
local branch for potential acoustic loss.
Double Layer Installations
Inner layers can be fixed at 600mm centres but outer layers must be fixed
at 300mm centres to the metal framework with the appropriate length
screw. The second layer of plasterboard should be fixed with all joints
staggered in relation to the first layer assuming studs fixed at 600mm
centres.
Fixing of Floor and Ceiling Tracks
All tracks must be secured to the floor and ceiling in the centre of the
profile at 600mm centres with suitable fixings.
Butt boards together- don’t force boards into position. Fix the boards
so that the decorative paper side is on the outside to receive jointing
treatment. Fixings must penetrate steelwork by a minimum of 10mm,
they should be installed not closer than 13mm from cut edges and 10mm
from their bound edges. The boards should be located on the site line on
the centre line of framing (except Speedline Acoustic studs where site line
is slightly
Partitioning Systems Stud & Track
Single Layer Installations
Plasterboard must be fixed at 300mm maximum centres to the metal
framework with the appropriate length screw. Plasterboard joints must be
staggered from one side of the partition to the other.
For all partitions i.e. C Studs, I Studs, Resilient Bar, Wall Liner and Wall
Furring the following applies:-
For 94mm and 148mm tracks we recommend two rows of staggered
fixings at 600mm centres.
Partition Brace
For fixing of Partition Brace or for joining stud to track
(if required) we recommend the use of wafer head screws.
Speedline Standard System
Partition
Grade
BS5234
Max
Height
m
Nominal
Width
mm
Fire
Resistance
BG Standard Wallboard
MD
2.5
77
30
N/A
Speedline C Studs with Standard
British Gypsum Boards
Sound Insulation RwdB
No
25mm
50mm
Infill
APR
APR
No
Infill
Certification Reference
25mm
50mm
APR
APR
50mm C Stud
1 x 12.5mm
39
41
50-B-51
50-B-51(25)
1 x 15mm
BG Standard Wallboard
HD
2.8
82
30
N/A
40
50-B-52
50-B-52(25)
2 x 12.5mm
BG Standard Wallboard
SD
3.4
102
60
43
47
50-B-57
50-B-57(25)
2 x 15mm
BG Standard Wallboard
SD
3.7
112
60
45
47
50-B-58
50-B-58(25)
BG Standard Wallboard
MD
3.6
97
30
37
41
70-B-51
70-B-51(25)
50-B-51(50)
70mm C Stud
1 x 12.5mm
1 x 15mm
BG Standard Wallboard
HD
3.8
102
30
37
41
70-B-52
70-B-52(25)
2 x 12.5mm
BG Standard Wallboard
SD
4.6
122
60
45
49
70-B-57
70-B-57(25)
2 x 15mm
BG Standard Wallboard
SD
4.9
132
60
46
50
70-B-58
70-B-58(25)
92mm C Stud
1 x 12.5mm
BG Standard Wallboard
MD
3.9
119
30
37
41
92-B-51
92-B-51(25)
1 x 15mm
BG Standard Wallboard
HD
4.4
124
30
37
41
92-B-52
92-B-52(25)
2 x 12.5mm
BG Standard Wallboard
SD
5.2
142
60
46
50
92-B-57
92-B-57(25)
2 x 15mm
BG Standard Wallboard
SD
5.9
152
60
46
50
92-B-58
92-B-58(25)
146mm C Stud
1 x 12.5mm
BG Standard Wallboard
MD
6.2
173
30
37
41
146-B-51
146-B-51(25)
1 x 15mm
BG Standard Wallboard
HD
6.5
178
30
37
41
146-B-52
146-B-52(25)
2 x 12.5mm
BG Standard Wallboard
SD
7.6
198
60
46
50
146-B-57
146-B-57(25)
2 x 15mm
BG Standard Wallboard
SD
7.9
208
60
46
50
146-B-58
146-B-58(25)
11
Partitioning Systems
Stud & Track – Product Performance Guide
Speedline Standard System
Speedline Standard System
Speedline C Studs with Standard
Knauf Boards
Partition
Grade
BS5234
Max
Height
m
Nominal
Width
mm
Fire
Resistance
Sound Insulation RwdB
No
25mm
50mm
Infill
APR
APR
No
Infill
Certification Reference
25mm
50mm
APR
APR
50mm C Stud
1 x 12.5mm
Knauf Standard Wallboard
MD
2.5
77
30
N/A
39
1 x 15mm
Knauf Standard Wallboard
HD
2.8
82
30
N/A
2 x 12.5mm
Knauf Standard Wallboard
SD
3.4
102
60
2 x 15mm
Knauf Standard Wallboard
SD
3.7
112
1 x 12.5mm
Knauf Standard Wallboard
MD
3.6
1 x 15mm
Knauf Standard Wallboard
HD
2 x 12.5mm
Knauf Standard Wallboard
2 x 15mm
42
50-K-51
50-K-51(25)
41
50-K-52
50-K-52(25)
42
47
50-K-57
50-K-57(25)
60
42
47
50-K-58
50-K-58(25)
97
30
N/A
42
70-K-51
70-K-51(25)
3.8
102
30
N/A
42
70-K-52
70-K-52(25)
SD
4.6
122
60
46
49
70-K-57
70-K-57(25)
Knauf Standard Wallboard
SD
4.9
132
60
46
49
70-K-58
70-K-58(25)
1 x 12.5mm
Knauf Standard Wallboard
MD
3.9
119
30
N/A
42
92-K-51
92-K-51(25)
1 x 15mm
Knauf Standard Wallboard
HD
4.4
124
30
N/A
42
92-K-52
92-K-52(25)
2 x 12.5mm
Knauf Standard Wallboard
SD
5.2
142
60
46
49
92-K-57
92-K-57(25)
2 x 15mm
Knauf Standard Wallboard
SD
5.9
152
60
46
49
92-K-58
92-K-58(25)
70mm C Stud
92mm C Stud
146mm C Stud
12
1 x 12.5mm
Knauf Standard Wallboard
MD
6.2
173
30
N/A
42
146-K-51
146-K-51(25)
1 x 15mm
Knauf Standard Wallboard
HD
6.5
178
30
N/A
42
146-K-52
146-K-52(25)
2 x 12.5mm
Knauf Standard Wallboard
SD
7.6
198
60
46
49
146-K-57
146-K-57(25)
2 x 15mm
Knauf Standard Wallboard
SD
7.9
208
60
46
49
146-K-58
146-K-58(25)
50-K-51(50)
Partitioning Systems
Stud & Track – Product Performance Guide
Speedline Standard System
Partition
Grade
BS5234
Max
Height
m
Nominal
Width
mm
Fire
Resistance
Sound Insulation RwdB
No
25mm
50mm
Infill
APR
APR
No
Infill
Certification Reference
25mm
50mm
APR
APR
50mm C Stud
1 x 12.5mm
Gtec Standard Wallboard
MD
2.5
77
0
N/A
N/A
50-S-51
50-S-51(25)
1 x 15mm
Gtec Standard Wallboard
HD
2.8
82
0
N/A
N/A
50-S-52
50-S-52(25)
2 x 12.5mm
Gtec Standard Wallboard
SD
3.4
102
60
42
46
50-S-57
50-S-57(25)
2 x 15mm
Gtec Standard Wallboard
SD
3.7
112
60
42
46
50-S-58
50-S-58(25)
1 x 12.5mm
Gtec E-board
MD
2.8
82
0
N/A
41
50-S-64
50-S-64(25)
1 x 12.5mm
Gtec Standard Wallboard
MD
3.6
97
30
N/A
40
70-S-51
70-S-51(25)
1 x 15mm
Gtec Standard Wallboard
HD
3.8
102
30
N/A
41
70-S-52
70-S-52(25)
2 x 12.5mm
Gtec Standard Wallboard
SD
4.6
122
60
45
49
70-S-57
70-S-57(25)
2 x 15mm
Gtec Standard Wallboard
SD
4.9
132
60
45
49
70-S-58
70-S-58(25)
1 x 12.5mm
Gtec E-board
MO
3.6
97
30
–
41
70-S-64
70-S-64(25)
1 x 12.5mm
Gtec Standard Wallboard
MD
3.9
119
30
N/A
40
92-S-51
92-S-51(25)
1 x 15mm
Gtec Standard Wallboard
HD
4.4
124
30
N/A
41
92-S-52
92-S-52(25)
2 x 12.5mm
Gtec Standard Wallboard
SD
5.2
142
60
45
49
92-S-57
92-S-57(25)
2 x 15mm
Gtec Standard Wallboard
SD
5.9
152
60
45
49
92-S-58
92-S-58(25)
70mm C Stud
Speedline Standard System
Speedline C Studs with
Siniat Gtec Standard Boards
92mm C Stud
146mm C Stud
1 x 12.5mm
Gtec Standard Wallboard
MD
6.2
173
30
N/A
40
146-S-51
146-S-51(25)
1 x 15mm
Gtec Standard Wallboard
HD
6.5
178
30
N/A
41
146-S-52
146-S-52(25)
2 x 12.5mm
Gtec Standard Wallboard
SD
7.6
198
60
45
49
146-S-57
146-S-57(25)
2 x 15mm
Gtec Standard Wallboard
SD
7.9
208
60
45
49
146-S-58
146-S-58(25)
Maximum Heights are calculated based on a limiting deflection of L/240 @ 200 Pascals.
All heights are for non-fire rated partitions or fire rated to BS476 Part 22 only.
13
Partitioning Systems
Stud & Track – Product Performance Guide
Speedline Fire System
Speedline Fire System
Speedline C Studs with
British Gypsum Fire Boards
Partition
Grade
BS5234
Max
Height
m
Nominal
Width
mm
Fire
Resistance
Sound Insulation RwdB
No
25mm
50mm
Infill
APR
APR
No
Infill
Certification Reference
25mm
50mm
APR
APR
50mm C Stud
1 x 12.5mm
BG Fireline
MD
2.5
77
30
N/A
39
1 x 15mm
BG Fireline
HD
2.8
82
60
N/A
2 x 12.5mm
BG Fireline
SD
3.4
102
120
2 x 15mm
BG Fireline
SD
3.7
112
1 x 12.5mm
BG Fireline
MD
3.6
1 x 15mm
BG Fireline
HD
2 x 12.5mm
BG Fireline
2 x 15mm
BG Fireline
41
50-B-55
50-B-55(25)
40
50-B-56
50-B-56(25)
43
47
50-B-61
50-B-61(25)
120
45
47
50-B-62
50-B-62(25)
97
30
37
41
70-B-55
70-B-55(25)
3.8
102
60
37
41
70-B-56
70-B-56(25)
SD
4.6
122
120
45
49
70-B-61
70-B-61(25)
SD
4.9
132
120
46
50
70-B-62
70-B-62(25)
BG Fireline
SD
4.6
122
120
1 x 12.5mm
BG Fireline
MD
3.9
119
30
37
41
92-B-55
92-B-55(25)
1 x 15mm
BG Fireline
HD
4.4
124
60
37
41
92-B-56
92-B-56(25)
2 x 12.5mm
BG Fireline
SD
5.2
142
120
46
50
92-B-61
92-B-61(25)
2 x 15mm
BG Fireline
SD
5.9
152
120
46
50
92-B-62
92-B-62(25)
70mm C Stud
AS70 Acoustic Stud
2 x 12.5mm
51
AS70-B-57(25)
92mm C Stud
146mm C Stud
14
1 x 12.5mm
BG Fireline
MD
6.2
173
30
37
41
146-B-55
146-B-55(25)
1 x 15mm
BG Fireline
HD
6.5
178
60
37
41
146-B-56
146-B-56(25)
2 x 12.5mm
BG Fireline
SD
7.6
198
120
46
50
146-B-61
146-B-61(25)
2 x 15mm
BG Fireline
SD
7.9
208
120
46
50
146-B-62
146-B-62(25)
50-B-56(50)
Partitioning Systems
Stud & Track – Product Performance Guide
Speedline Fire System
Partition
Grade
BS5234
Max
Height
m
Nominal
Width
mm
Fire
Resistance
Sound Insulation RwdB
No
25mm
50mm
Infill
APR
APR
No
Infill
Certification Reference
25mm
50mm
APR
APR
50mm C Stud
1 x 12.5mm
Knauf Fire Panel
MD
2.5
77
30
N/A
39
1 x 15mm
Knauf Fire Panel
HD
2.8
82
60
N/A
2 x 12.5mm
Knauf Fire Panel
SD
3.4
102
90
2 x 15mm
Knauf Fire Panel
SD
3.7
112
1 x 12.5mm
Knauf Fire Panel
MD
3.6
1 x 15mm
Knauf Fire Panel
HD
2 x 12.5mm
Knauf Fire Panel
2 x 15mm
42
50-K-55
50-K-55(25)
41
50-K-56
50-K-56(25)
42
47
50-K-61
50-K-61(25)
90
42
47
50-K-62
50-K-62(25)
97
30
N/A
42
70-K-55
70-K-55(25)
3.8
102
60
N/A
43
70-K-56
70-K-56(25)
SD
4.6
122
90
46
49
70-K-61
70-K-61(25)
Knauf Fire Panel
SD
4.9
132
90
46
49
70-K-62
70-K-62(25)
1 x 12.5mm
Knauf Fire Panel
MD
3.9
119
30
N/A
42
92-K-55
92-K-55(25)
1 x 15mm
Knauf Fire Panel
HD
4.4
124
60
N/A
43
92-K-56
92-K-56(25)
2 x 12.5mm
Knauf Fire Panel
SD
5.2
142
90
46
49
92-K-61
92-K-61(25)
2 x 15mm
Knauf Fire Panel
SD
5.9
152
90
46
49
92-K-62
92-K-62(25)
70mm C Stud
50-K-55(50)
Speedline Fire System
Speedline C Studs with
Knauf Fire Boards
92mm C Stud
146mm C Stud
1 x 12.5mm
Knauf Fire Panel
MD
6.2
173
30
N/A
42
146-K-55
146-K-55(25)
1 x 15mm
Knauf Fire Panel
HD
6.5
178
60
N/A
43
146-K-56
146-K-56(25)
2 x 12.5mm
Knauf Fire Panel
SD
7.6
198
90
46
49
146-K-61
146-K-61(25)
2 x 15mm
Knauf Fire Panel
SD
7.9
208
90
46
49
146-K-62
146-K-62(25)
Maximum Heights are calculated based on a limiting deflection of L/240 @ 200 Pascals.
All heights are for non-fire rated partitions or fire rated to BS476 Part 22 only.
15
Partitioning Systems
Stud & Track – Product Performance Guide
Speedline Fire System
Speedline Fire System
Speedline C Studs with
Siniat Gtec Fire Boards
Partition
Grade
BS5234
Max
Height
m
Nominal
Width
mm
Fire
Resistance
Sound Insulation RwdB
No
25mm
50mm
Infill
APR
APR
No
Infill
Certification Reference
25mm
50mm
APR
APR
50mm C Stud
1 x 15mm
Gtec Fireboard
HD
2.8
82
60
N/A
41
50-S-56
50-S-56(25)
2 x 12.5mm
Gtec Fireboard
SD
3.4
102
90
42
46
50-S-61
50-S-61(25)
2 x 15mm
Gtec Fireboard
SD
3.7
112
120
42
46
50-S-62
50-S-62(25)
1 x 12.5mm
Gtec Fireboard
MD
3.6
97
30
N/A
40
70-S-55
70-S-55(25)
1 x 15mm
Gtec Fireboard
HD
3.8
102
60
N/A
41
70-S-56
70-S-56(25)
2 x 12.5mm
Gtec Fireboard
SD
4.6
122
90
45
49
70-S-61
70-S-61(25)
2 x 15mm
Gtec Fireboard
SD
4.9
132
120
45
53
70-S-62
70-S-62(25)
1 x 12.5mm
Gtec Fireboard
MD
3.9
119
30
N/A
40
92-S-55
92-S-55(25)
1 x 15mm
Gtec Fireboard
HD
4.4
124
60
N/A
41
92-S-56
92-S-56(25)
2 x 12.5mm
Gtec Fireboard
SD
5.2
142
90
45
49
92-S-61
92-S-61(25)
2 x 15mm
Gtec Fireboard
SD
5.9
152
120
45
53
92-S-62
92-S-62(25)
70mm C Stud
92mm C Stud
146mm C Stud
16
1 x 12.5mm
Gtec Fireboard
MD
6.2
173
30
N/A
40
146-S-55
146-S-55(25)
1 x 15mm
Gtec Fireboard
HD
6.5
178
60
N/A
41
146-S-56
146-S-56(25)
2 x 12.5mm
Gtec Fireboard
SD
7.6
198
90
45
49
146-S-61
146-S-61(25)
2 x 15mm
Gtec Fireboard
SD
7.9
208
120
45
53
146-S-62
146-S-62(25)
Partitioning Systems
Stud & Track – Product Performance Guide
Speedline Acoustic System
Partition
Grade
BS5234
Max
Height
m
Nominal
Width
mm
Fire
Resistance
Sound Insulation RwdB
No
25mm
50mm
Infill
APR
APR
No
Infill
Certification Reference
25mm
50mm
APR
APR
50mm C Stud
1 x 12.5mm
BG SoundBloc
MD
2.5
77
30
N/A
44
50-B-53
50-B-53(25)
1 x 15mm
BG SoundBloc
HD
2.8
82
30
39
44
50-B-54
50-B-54(25)
2 x 12.5mm
BG SoundBloc
SD
3.4
102
60
46
52
50-B-59
50-B-59(25)
2 x 15mm
BG SoundBloc
SD
3.7
112
90
48
54
50-B-60
50-B-60(25)
1 x 12.5mm
BG SoundBloc
MD
3.6
97
30
40
45
70-B-53
70-B-53(25)
1 x 15mm
BG SoundBloc
HD
3.8
102
30
42
46
70-B-54
70-B-54(25)
2 x 12.5mm
BG SoundBloc
SD
4.6
122
60
52
55
70-B-59
70-B-59(25)
2 x 15mm
BG SoundBloc
SD
4.9
132
90
53
56
70-B-60
70-B-60(25)
45
50-B-54(50)
70mm C Stud
Speedline Acoustic System
Speedline C Studs with
British Gypsum Acoustic Boards
AS70 Acoustic Stud
1 x 12.5mm
1 x 15mm
BG Soundbloc Wallboard Inner
BG Duraline Outer
SD
4.6
127
60
53
60
AS70-B-56
AS70-B-56(25)
1 x 12.5mm
BG SoundBloc
MD
3.6
97
30
42
47
AS70-B-54
AS70-B-54(25)
1 x 15mm
BG SoundBloc
HD
3.8
102
30
2 x 12.5mm
BG SoundBloc
SD
4.6
122
60
1 x 12.5mm
BG SoundBloc
MD
3.9
119
30
40
45
92-B-53
92-B-53(25)
1 x 15mm
BG SoundBloc
HD
4.4
124
30
42
46
92-B-54
92-B-54(25)
2 x 12.5mm
BG SoundBloc
SD
5.2
142
60
52
56
92-B-59
92-B-59(25)
2 x 15mm
BG SoundBloc
SD
5.9
152
90
53
56
92-B-60
92-B-60(25)
50
AS70-B-53(50)
58
AS70-B-55(25)
92mm C Stud
146mm C Stud
1 x 12.5mm
BG SoundBloc
MD
6.2
173
30
40
45
146-B-53
146-B-53(25)
1 x 15mm
BG SoundBloc
HD
6.5
178
30
42
46
146-B-54
146-B-54(25)
2 x 12.5mm
BG SoundBloc
SD
7.6
198
60
52
56
146-B-59
146-B-59(25)
2 x 15mm
BG SoundBloc
SD
7.9
208
90
53
56
146-B-60
146-B-60(25)
Maximum Heights are calculated based on a limiting deflection of L/240 @ 200 Pascals.
All heights are for non-fire rated partitions or fire rated to BS476 Part 22 only.
17
Partitioning Systems
Stud & Track – Product Performance Guide
Speedline Acoustic System
Speedline Acoustic System
Speedline C Studs with
Knauf Acoustic Boards
Partition
Grade
BS5234
Max
Height
m
Nominal
Width
mm
Fire
Resistance
Sound Insulation RwdB
No
25mm
50mm
Infill
APR
APR
No
Infill
Certification Reference
25mm
50mm
APR
APR
50mm C Stud
1 x 12.5mm
Knauf Soundshield plus
MD
2.5
77
30
N/A
44
50-K-53
50-K-53(25)
1 x 15mm
Knauf Soundshield plus
HD
2.8
82
30
38
44
50-K-54
50-K-54(25)
2 x 12.5mm
Knauf Soundshield plus
SD
3.4
102
60
47
52
50-K-59
50-K-59(25)
2 x 15mm
Knauf Soundshield plus
SD
3.7
112
90
49
52
50-K-60
50-K-60(25)
1 x 12.5mm
Knauf Soundshield plus
MD
3.6
97
30
40
45
70-K-53
70-K-53(25)
1 x 15mm
Knauf Soundshield plus
SD
3.8
102
60
42
47
70-K-54
70-K-54(25)
2 x 12.5mm
Knauf Soundshield plus
SD
4.6
122
60
50
55
70-K-59
70-K-59(25)
2 x 15mm
Knauf Soundshield plus
SD
4.9
132
90
53
55
70-K-60
70-K-60(25)
42
47
70mm C Stud
AS 70mm Acoustic C Stud
1 x 15mm
Knauf Sound Shield plus
SD
3.8
102
60
48
AS 70-K-53
AS 70-K-53(25) AS 70-K-53(50)
2 x 15mm
Knauf Sound Shield plus
SD
4.9
132
90
1 x 12.5mm
Knauf Soundshield plus
MD
3.9
119
30
41
46
92-K-53
92-K-53(25)
1 x 15mm
Knauf Soundshield plus
SD
4.4
124
60
42
47
92-K-54
92-K-54(25)
2 x 12.5mm
Knauf Soundshield plus
SD
5.2
142
60
51
55
92-K-59
92-K-59(25)
2 x 15mm
Knauf Soundshield plus
SD
5.9
152
90
53
55
92-K-60
92-K-60(25)
57
AS 70-K-58(50)
92mm C Stud
146mm C Stud
18
1 x 12.5mm
Knauf Soundshield plus
MD
6.2
173
30
42
47
146-K-53
146-K-53(25)
1 x 15mm
Knauf Soundshield plus
SD
6.5
178
60
42
47
146-K-54
146-K-54(25)
2 x 12.5mm
Knauf Soundshield plus
SD
7.6
198
60
52
55
146-K-59
146-K-59(25)
2 x 15mm
Knauf Soundshield plus
SD
7.9
208
90
53
55
146-K-60
146-K-60(25)
Partitioning Systems
Stud & Track – Product Performance Guide
Speedline Acoustic System
Partition
Grade
BS5234
Max
Height
m
Nominal
Width
mm
Fire
Resistance
Sound Insulation RwdB
No
25mm
50mm
Infill
APR
APR
No
Infill
Certification Reference
25mm
50mm
APR
APR
50mm C Stud
1 x 12.5mm
Gtec dB Board
MD
2.5
77
N/A
N/A
42
50-S-53
50-S-53(25)
1 x 15mm
Gtec dB Board
HD
2.8
82
N/A
38
42
50-S-54
50-S-54(25)
2 x 12.5mm
Gtec dB Board
SD
3.4
102
60
46
50
50-S-59
50-S-59(25)
2 x 15mm
Gtec dB Board
SD
3.7
112
60
47
50
50-S-60
50-S-60(25)
1 x 12.5mm
Gtec dB Board
MD
3.6
97
30
40
45
70-S-53
70-S-53(25)
1 x 15mm
Gtec dB Board
HD
3.8
102
30
41
45
70-S-54
70-S-54(25)
2 x 12.5mm
Gtec dB Board
SD
4.6
122
60
50
52
70-S-59
70-S-59(25)
2 x 15mm
Gtec dB Board
SD
4.9
132
60
50
53
70-S-60
70-S-60(25)
Gtec dB Board
SD
4.9
132
60
1 x 12.5mm
Gtec dB Board
MD
3.9
119
30
40
45
92-S-53
92-S-53(25)
1 x 15mm
Gtec dB Board
HD
4.4
124
30
41
45
92-S-54
92-S-54(25)
2 x 12.5mm
Gtec dB Board
SD
5.2
142
60
50
52
92-S-59
92-S-59(25)
2 x 15mm
Gtec dB Board
SD
5.9
152
60
50
53
92-S-60
92-S-60(25)
70mm C Stud
Speedline Acoustic System
Speedline C Studs with
Siniat Gtec Acoustic Boards
AS 70mm Acoustic C Stud
2 x 15mm
56
AS70-S-58(50)
92mm C Stud
146mm C Stud
1 x 12.5mm
Gtec dB Board
MD
6.2
173
30
40
45
146-S-53
146-S-53(25)
1 x 15mm
Gtec dB Board
HD
6.5
178
30
41
45
146-S-54
146-S-54(25)
2 x 12.5mm
Gtec dB Board
SD
7.6
198
60
50
52
146-S-59
146-S-59(25)
2 x 15mm
Gtec dB Board
SD
7.9
208
60
50
53
146-S-60
146-S-60(25)
Maximum Heights are calculated based on a limiting deflection of L/240 @ 200 Pascals.
All heights are for non-fire rated partitions or fire rated to BS476 Part 22 only.
19
Partitioning Systems
Speedline High Impact System
Stud & Track – Product Performance Guide
Speedline High Impact System
Speedline Studs with
British Gypsum Boards
Partition
Grade
BS5234
Max
Height
m
Nominal
Width
mm
Fire
Resistance
SD
4.2
102
60
Sound Insulation RwdB
No
25mm
50mm
Infill
APR
APR
No
Infill
Certification Reference
25mm
50mm
APR
APR
PSHD70 - Heavy Duty Stud
1 x 15mm
BG Duraline
44
47
48
48
50
HD70-B-51
HD70-B-51(25)
HD70-B-51(50)
AS70-B-51(25)
AS70-B-51(50)
AS70 - Acoustic Stud
1 x 15mm
BG Duraline
SD
3.8
102
60
1 x 12.5mm
1 x 15mm
BG SoundBloc Inner
BG Duraline Outer
SD
4.6
127
60
53
60
AS70-B-56
AS70-B-56(25)
SD
4.2
102
60
39
43
HD70-K-51
HD70-K-51(25)
40
43
AS70-K-51
AS70-K-51(25)
With Knauf Boards
PSHD70 - Heavy Duty Stud
1 x 15mm
Knauf Impact Panel
AS70 - Acoustic Stud
1 x 15mm
Knauf Impact Panel
SD
3.8
102
60
2 x 15mm
Knauf Impact Panel
SD
4.9
132
90
57
46
AS70-K-51(50)
AS70-K-52(25)
With Siniat Gtec Boards
AS70 - Acoustic Stud
1 x 15mm
Gtec Megadeco
SD
3.8
102
60
47
48
AS70-S-51(25)
1 x 1 5mm
dB board Inner- 15mm Megadeco Outer
SD
4.9
132
90
56
1 x 15mm
Gtec Megadeco
SD
3.8
102
60
1 x 12.5mm
1 x 15mm
Standard Wellboard - Inner
Megadeco - Outer
SD
4.6
127
60
52
70-S-65(25)
1 x 15mm
dB board Inner- 15mm Megadeco Outer
SD
4.9
132
90
53
70-S-66(25)
AS70-S-51(50)
AS70-S-56(25)
70mm C Stud
Maximum Heights are calculated based on a limiting deflection of L/240 @ 200 Pascals.
All heights are for non-fire rated partitions or fire rated to BS476 Part 22 only.
20
40
44
47
70-S-63
70-S-63(25)
70-S-63(50)
Partitioning Systems
Stud & Track
Fire Rated Acoustic
Sealant
Fire Rated
Acoustic Sealant
Mineral Fibre
Deep Track
Deep Track
Stud
Stud
Partition Brace (PB)
Partition Brace (PB)
Partitioning Systems
Cloaking Angle (SL06)
Deflection head
When partitions are erected to span the
full height between floors, structural slabs or
beams, accommodation for movement may
be needed. The deflection heads shown will
allow for movement up to 15mm and protect
the partition from damage. These details have
been both tested for fire resistance to BS 476
part 20 & 22 section 5. Fix plasterboard,
allowing for a 15mm deflection at the
partition head; do not screw fix the
plasterboard to the studs or track above the
Partition Brace.
* Above 15mm please refer to local branch.
Deflection heads can lose up to 4dB on
acoustic performance, please contact local
branch for details.
Electrical Services Acoustic Insulation
Insulation
25mm glass mineral wool
insulation or 30mm rock
mineral wool insulation to be
installed 300mm above and
300mm below metal socket box
for full width between studs
Wallboard fixed to back of
FS24 or PB24
End cut and bent to fit
stud centres
To ensure they do not lie back to back,
electrical sockets should be offset. Use Flat
Strip FS24 or Partition Brace PB24 to support
outlet boxes and seal around with acoustic
sealant. Two layers, either side of 12.5mm
standard plasterboard, will achieve 60
minutes of fire resistance.
Putty Pads shown on page 81.
Clamping Strip
The Speedline galvanised clamping strip is
used to cover joints when building partitions
and either a plastic or aluminium cover
section clips over the clamping strip to give a
good finished appearance.
Clamping Strip
Product
Code
PCS20
Product Description
20mm Clamping Strip x 0.5mm
Stock Lengths
Metre
2.400
2.700
3.000
3.600
Weight per
Length Kgs
0.28
0.32
0.36
0.42
21
Download