Dual Duct EVC Series VAV Dual Duct Controller & Actuator The VAV package consists of 2 parts, namely the thermostat and the EVC which is a combination of an actuator and a controller, which mounts directly to the damper jackshaft on the side of the VAV box. The dual duct version consists of two models: a master controller (EVCBM14WIT2S) mounted on the cold duct damper and a slave controller (EVCS14) mounted on the hot duct damper. Typical Dual Duct Application Dual Duct Dual duct air handling systems divide supply air at the central fan. Hot and cold air flow through two separate inlets and the air is mixed as defined by the controller and the thermostat in the controlled space. The mixed air is then discharged through one outlet into the space. www.neptronic.com Models • EVCBM14WI1S: Master Controller (cold duct) • EVCS14: Slave Controller (hot duct) Control Features • • • • • • • • • • • • Field configured VAV algorithms Built-in actuator with brushless motor (70 in.lb.) [8 Nm] On board differential pressure sensor Simple air balancing and commissioning via thermostat Precise temperature control with programmable PI (Proportional-Integral) function Selectable proportional control band and dead band per signal ramp Selectable internal or external temperature sensor (10Kø) Change over by contact or external temperature sensor Internal and external temperature sensor calibration Anti-freeze protection Configurable integration time factor Configurable anti-cycling delay BACnet Features • • • • • • BACnet® MS/TP @ 9600, 19200, 38400, or 76800 bps Automatic Baud Rate Detection Copy and broadcast configuration to other networked EVCB controllers Automatically assigns the MAC address and the device instance Selectable MAC Address by DIP switch Over 100 BACnet Objects available for status, operation, configuration Inputs and Outputs • 2 Analog Inputs • • • - Selectable input type (External temperature sensor, external changeover sensor, normally cool changeover contact, normally Heat changeover contact, or off) 2 Digital Inputs - DI1: Selectable input type (NO/NC occupancy, or NO/NC Night Set Back) - DI2: BACnet only 2 TRIAC outputs - Selectable signal ramp (Cool 1, Cool 2, Heat 1, Heat 2, Heat 3 or Off) - Selectable output signal (On/Off, Pulse, or Floating) - Configurable on/off closing and opening level (if set to On/Off) - Selectable floating time and direction (if set to Floating) 2 Analog Outputs - Selectable signal ramp (Cool 1, Cool 2, Heat 1, Heat 2, Heat 3 or Off) - Configurable minimum and maximum voltage Operational Features • • • • • • Backlit LCD with simple icon and text driven menus Manual night set back or no occupancy override Multi level lockable access menu Lockable setpoint Removable, raising clamp, non-strip terminals 24Vac thermal fuse for overheat protection www.neptronic.com 130015_GB (150821)