H100 COND Transmitter Specification Data Sheet Hamilton H100 COND Transmitter combines ease of use and reliability. It has been designed for universal process application including use in pharmaceutical, chemical, food & beverage industries as well as water / waste water treatment. The self-explaining user interface ensures comfortable and intuitive handling. Hamilton H100 COND Transmitter provides continuous sensor monitoring and preventive maintenance indication for maximal reliability. H100 COND Specifications COND input Input for 2-electrodes or 4-electrodes Effective ranges Conductivity 0.2 • c ... 1000 mS • c Measuring ranges Conductivity 0.000 ... 9.999 μS/cm 00.00 ... 99.99 μS/cm 000.0 ... 999.9 μS/cm 0000 ... 9999 μS/cm 0.000 ... 9.999 mS/cm 00.00 ... 99.99 mS/cm 000.0 ... 999.9 mS/cm 0.000 ... 9.999 S/cm 00.00 ... 99.99 S/cm Resistivity 00.00 ... 99.99 MOhm • cm Concentration 0.00 ... 9.99 % by wt Salinity 0.0 ... 45.0 ‰ (0 ... 35 °C) Response tine (T 90 ) < 1 s (Sensocheck off) < 3 s (Sensocheck on) Meas. error < 1 % meas. val. + 0.4 μS • c 1, 2, 3) Concentration Determination 01 NaCI Modes 02 HCI 03 NaOH 04 H 2SO 4 05 HNO 3 *) Sensor standardization Operating modes - Input of cell constant with simultaneous display of conductivity and temperature - Input of conductivity of calibration solution with simultaneous display of cell constant and aitemperature - Product calibration - Temperature probe adjustment Permissible cell constant H100 DO Specifications (continued) Sensor monitoring Sensocheck Polarization detection and monitoring of cable capacitance ® Provides information on the sensor condition (Sensocheck ®) Sensor monitor Direct display of measured values from sensor for validation (resistance / temperature) Temperature input *) Pt 100 / Pt 1000 / NTC 30 kOhm 2-wire connection, adjustable Measuring range Pt 100 / Pt 1000 -20.0 ... +200.0 °C (-4 ... +392 °F) NTC 30 kOhm Resolution i -20.0 ... +150.0 °C (-4 ... +302 °F) 0.1 °C / 0.1 °F Meas. error < 0.5 (< 1K for Pt 100; < 1K for NTC >100 °C) 1, 2, 3) Temperature compensation (ref. temperature 25 °C) i i Output 1 Overrange 0/4 … 20 mA, max. 10 V, floating (galvanically connected to output 2) 22 mA in the case of error messages *) Output filter Low-pass, filter time constant: 0 … 120 s *) Minumum spam Process variable Temperature Measurement error Start/end of scale 1) < 0.3 % current value + 0.05 mA *) Permissible span Alarm contact Relay contact, floating Display approx. 5 VA, 2.5 W Overvoltage category II, protection class II Ambient temperature –20 … +55 °C Transport/Storage temp –20 … +70 °C Relative humidity EMC Emitted interference Class B (residential area), Immunity to interference Industry Enclosure Molded enclosure made from PBT (polybutylene terephtlate) pipe mounting 243082 ( Ingress protection IP 65 / NEMA 4X *) User-defined; 1) To IEC 746 Part 1, at nominal operating conditions; 2) ±1 count; 3) Plus sensor error © 2013 Hamilton Bonaduz AG. All rights reserved. Calimatic ® and Sensocheck® are registed trademarks by Knick Elektronische Messgeräte GmbH & Co. KG P/N: 695155/00 — 11/2013 Hamilton Americas & Pacific Rim Web: www.hamiltoncompany.com 800-648-5950 Europe: +41-81-660-60-60 USA: 4970 Energy Way Reno, Nevada 89502 USA Tel: +1-775-858-3000 Fax: +1-775-856-7259 sales@hamiltoncompany.com Hamilton Europe, Asia, & Africa Via Crusch 8 CH-7402 Bonaduz, Switzerland Tel: +41-81-660-60-60 Fax: +41-81-660-60-70 contact@hamilton.ch To find a representative in your area, please visit hamiltoncompany.com/contacts.