VIPER™ TYPE SOOW 90°C 600 Volt UL/CSA Portable Cord Bare Copper Conductors A P P L I C A T I ON S EPDM Conductors Suitable for use as follows: •Portable tools and equipment • Portable appliances BLACK VIPER™ CPE Jacket •Small motors and associated machinery S T A ND A R D S & REFERENCES •Sizes 18 AWG - 10 AWG: UL Standard 62 for Flexible Cords and CSA Standard 22.2 No. 49 for Flexible Cords •Sizes 8 AWG - 2 AWG are non-UL and non-CSA Listed, but meet industry-accepted standards for insulation and jacket thickness •All sizes meet the Mine Safety and Health Administration (MSHA) Flame Resistance for Mining Applications •All sizes comply with Federal and Military Specification JC-580B •NEC Article 400 •OSHA C ON S T R U C T I ON Extra-Flexible Stranding Abrasion Resistant • Conductors: 18 through 10 AWG fully annealed stranded bare copper per ASTM B-174 8 through 2 AWG fully annealed stranded bare copper Resists Oils and Solvents • Insulation: Flame Resistant •Jacket: Ozone Resistant 90°C Rated Conductors and Jacket Water Resistant UL Listed and CSA Certified for Indoor and Outdoor Use Premium-grade, color-coded, 90°C EPDM Viper™, 90°C, black­ Temperature range: -40°C to +90°C • Sample Jacket Marking: Southwire VIPER™ (S) 3/C 12 AWG (3.31 mm2) SOOW (UL) 600V (-40°C TO +90°C) WATER RESISTANT CSA FT-2 P-123-103-MSHA RoHS MADE IN USA PACKAGING • 250' (76.2 m), 1000' (304.8 m) • Other put-ups available on special order WEIG H T S , NUMBER OF SIZE CONDUCTOR CONDUCTORS (AWG) STRAND ME A S U R E M E N T S Nominal Insulation Thickness A ND P ACK A GI N G NOMINAL overall diameter inches mm inches mm APPROX. Current NET weight stANDARD CARTON amps** lbs/m'† 2 18 16/30 0.030 0.76 0.345 8.76 10 70 250' 3 18 16/30 0.030 0.76 0.365 9.27 10 80 250' 4 18 16/30 0.030 0.76 0.390 9.91 7 95 250' 2 16 26/30 0.030 0.76 0.370 9.40 13 80 250' 3 16 26/30 0.030 0.76 0.390 9.91 13 95 250' 4 16 26/30 0.030 0.76 0.420 10.67 10 115 250' 2 14 41/30 0.045 1.14 0.510 12.96 18 135 250' 3 14 41/30 0.045 1.14 0.535 13.59 18 170 250' 4 14 41/30 0.045 1.14 0.575 14.61 15 205 250' 2 12 65/30 0.045 1.14 0.570 14.48 25 195 250' 3 12 65/30 0.045 1.14 0.595 15.11 25 225 250' 4 12 65/30 0.045 1.14 0.650 16.51 20 270 250' 2 10 104/30 0.045 1.14 0.620 15.75 30 250 250' 3 10 104/30 0.045 1.14 0.660 16.76 30 290 250' 4 10 104/30 0.045 1.14 0.715 18.16 25 355 250' 2 8* 65/36 0.050 1.27 0.660 16.76 40 290 250' 3 8* 65/26 0.050 1.27 0.720 18.29 40 365 250' 4 8* 65/26 0.050 1.27 0.780 19.31 35 500 250' 5 8* 65/26 0.050 1.27 0.860 21.84 28 545 250' 3 6* 101/26 0.050 1.27 0.800 20.32 55 515 250' 4 6* 101/26 0.050 1.27 0.845 21.46 45 620 250' 5 6* 101/26 0.050 1.27 0.945 24.00 36 750 250' 2 4* 119/25 0.050 1.27 0.890 22.61 70 500 250' 3 4* 119/25 0.050 1.27 0.940 23.83 70 670 250' 4 4* 119/25 0.050 1.27 1.010 25.65 60 835 250' 5 4* 119/25 0.050 1.27 1.135 28.33 48 1065 250' 3 2* 133/.0211 0.055 1.40 1.090 27.69 95 1030 250' 4 2* 133/.0211 0.055 1.40 1.170 29.72 80 1285 250' 5 2* 133/.0211 0.055 1.40 1.435 36.45 64 1620 250' 2 3 4 5 COLOR SEQUENCE # OF CONDUCTORS * Not UL or CSA, but manufactured to acceptable commercial standards. Sizes 8 AWG - 2 AWG are non-UL and non-CSA, but the option is available. ** Values shown are for current-carrying conductors. A grounding conductor, or one which carries only the unbalance current from other conductors, is NOT counted in determining current-carrying capacity. † Actual shipping weight may vary. COLOR white, white, white, white, C OD I N G black black, green black, red, green black, red, orange, green V I P E R ™ T Y P E S OO W 9 0 ° C 6 0 0 V olt U L / C S A P ortable C ord VIPER™ RUBBER CORD