NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 I.S./H.S. 362 - BRONX, 921 EAST 228TH STREET, BRONX, NY, 10466 School: InspectionId Inspection Type 12028 ELECTRICAL Time In Last Edited 2015-04-09 09:03AM 2015-06-08 11:34AM Asset Data Question Answer Have any Systems/Major Building Components been upgraded? Systems: IPDVS/CCTV System Years: Systems: 2010 All Other Systems And Components Years: 2008 Below Ground Type of Service Does Interactive Whiteboard (IWB) Exist? Yes DEDICATED INTERCOMS IN FIRE RESCUE AREAS Question Are there any Life Rescue Assistance Areas, Fire Rescue Areas, and/or Holding Rooms in your building? Are dedicated intercoms available in all of these spaces for use during a fire? Are all dedicated intercoms operational? Response Yes Yes Yes Priority Condition Priority Condition Exist Last Year? Priority Category Condition Description Component Affected Location Description Person(s) Notified No Fire Alarm System - Not Connected to Central Station Fire Alarm System - Digital Communicator Room 116B Michael Andrews Building Manager No Photo Tak No Emergency Generator Components - Not Operational Water Penetration in Electrical Room Fire Alarm System Digital Communic ator Not Connected to Central Station Emergency Generator Not Operational Emergency Generator Lower Roof Generator Enclosure Michael Andrews Building Manager No Photo Tak Water Penetration in Electrical Room Electrical Room Used as Storage Not Operational Electrical Equipment Room 120 Michael Andrews Building Manager No Photo Tak Electrical Equipment Room 118 Michael Andrews Building Manager No Photo Tak Fire Alarm System Magnetic Door Holder/Contact or 1st Floor Michael Andrews Building Manager No Photo Tak No No Electrical Room Used as Storage Fire Alarm System Components Not Operational No Person(s) Title PhotoImage Inspection Question Response Electrical Does not exist ATHLETIC FIELD AUDITORIUM Inspected Instance on 1st Floor House Lighting Inspected No Instance on 1st Floor Does a Chandelier Exist? Lighting Fixture - Fluorescent Inspected Instance on 1st Floor Pendant Mounted Inspected Instance on 1st Floor Mobile Validity Version 2.0 (P) Page 1 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response AUDITORIUM House Lighting Lighting Fixture - Fluorescent Pendant Mounted Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Recessed Mounted Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Surface Mounted Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Lighting Fixture - HID Does not exist Instance on 1st Floor Lighting Fixture - Incandescent Inspected Instance on 1st Floor Pendant Mounted Does not exist Instance on 1st Floor Recessed Mounted Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Surface Mounted Does not exist Instance on 1st Floor Lighting Fixture - LED Does not exist Instance on 1st Floor Local Sound System Instance on 1st Floor Inspected Instance Condition Installation Year Source of Installation Year 2- Between Good and Fair Deficiency No deficiencies recorded 2008 Documented Projection System Does not exist Instance on 1st Floor Theater Lighting System Inspected Instance on 1st Floor Dimming System Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Theater Lighting Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected AUXILIARY SIGNAL/BELL SYSTEM 2- Between Good and Fair Condition Deficiency No deficiencies recorded CAFETERIA Instance on 1st Floor - Students Inspected Instance on Room 147 - Staff Inspected Instance on 1st Floor - Students Inspected Lighting Mobile Validity Version 2.0 (P) Page 2 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response CAFETERIA Lighting Inspected Instance on Room 147 - Staff Lighting Fixture - Fluorescent Instance on 1st Floor - Students Inspected Instance on Room 147 - Staff Inspected Pendant Mounted Instance on 1st Floor - Students Does not exist Instance on Room 147 - Staff Does not exist Recessed Mounted Instance on 1st Floor - Students Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Room 147 - Staff Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Surface Mounted Instance on 1st Floor - Students Does not exist Instance on Room 147 - Staff Does not exist Lighting Fixture - HID Instance on 1st Floor - Students Does not exist Instance on Room 147 - Staff Does not exist Lighting Fixture - Incandescent Instance on 1st Floor - Students Does not exist Instance on Room 147 - Staff Does not exist Lighting Fixture - LED Instance on 1st Floor - Students Does not exist Instance on Room 147 - Staff Does not exist Local Sound System Instance on 1st Floor - Students Inspected Instance Condition Installation Year Source of Installation Year 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Room 147 - Staff Does not exist 2008 Documented Projection System Instance on 1st Floor - Students Does not exist Instance on Room 147 - Staff Does not exist Theater Lighting System Instance on 1st Floor - Students Does not exist Instance on Room 147 - Staff Does not exist Inspected CITY FIRE ALARM SYSTEM 4- Between Fair and Poor Condition Deficiency Deficiency Location/Instance Deficiency Quantity NOT OPERATIONAL Corridor Near Room 223 1 EACH REPAIR PRIORITY 5 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected CLASSROOM/CORRIDOR/ADMINISTRATIVE SPACE Inspected Lighting Does a Chandelier Exist? No Inspected Lighting Fixture - Fluorescent Mobile Validity Version 2.0 (P) Page 3 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response CLASSROOM/CORRIDOR/ADMINISTRATIVE SPACE Lighting Lighting Fixture - Fluorescent Inspected Pendant Mounted 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Recessed Mounted 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Surface Mounted 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Lighting Fixture - HID Pendant Mounted Does not exist Recessed Mounted Does not exist Surface Mounted Inspected 2- Between Good and Fair Condition Deficiency Deficiency Quantity LIGHTING FIXTURE NOT OPERATIONAL 4 EACH REPAIR PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected Lighting Fixture - Incandescent Pendant Mounted Does not exist Recessed Mounted Does not exist Surface Mounted Inspected 2- Between Good and Fair Condition Deficiency No deficiencies recorded Does not exist Lighting Fixture - LED COMPUTER LAB Instance on Rooms 243, 341, 441 Inspected Has LAN/Modem access Yes Power Panel? Yes Instance on Room 227 Inspected Has LAN/Modem access Yes Power Panel? No Instance on Rooms 243, 341, 441 Inspected Instance on Room 227 Inspected Lighting Lighting Fixture - Fluorescent Instance on Rooms 243, 341, 441 Inspected Instance on Room 227 Inspected Pendant Mounted Instance on Rooms 243, 341, 441 Does not exist Instance on Room 227 Does not exist Recessed Mounted Instance on Rooms 243, 341, 441 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Room 227 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Mobile Validity Version 2.0 (P) Page 4 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response COMPUTER LAB Lighting Lighting Fixture - Fluorescent Surface Mounted Instance on Rooms 243, 341, 441 Does not exist Instance on Room 227 Does not exist Lighting Fixture - HID Instance on Rooms 243, 341, 441 Does not exist Instance on Room 227 Does not exist Lighting Fixture - Incandescent Instance on Rooms 243, 341, 441 Does not exist Instance on Room 227 Does not exist Lighting Fixture - LED Instance on Rooms 243, 341, 441 Does not exist Instance on Room 227 Does not exist Raceway With Receptacles Instance on Rooms 243, 341, 441 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Room 227 Does not exist EMERGENCY DC STANDBY BATTERY POWER Does not exist EMERGENCY GENERATOR SET Inspected Automatic Transfer Switch (ATS) Inspected Instance Room 118 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Installation Year Source of Installation Year ASCO N/A 400 Amps Nameplate 2008 Documented Deficiency Deficiency Quantity ATS ID MISSING 1 EACH MAINTENANCE PRIORITY 2 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Instance Room 118 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Installation Year Source of Installation Year ASCO Fire Alarm Automatic Transfer Switch 30 Amps Nameplate 2008 Documented Deficiency No deficiencies recorded Instance Instance Condition Room 116B 2- Between Good and Fair Instance Quantity 1 Mobile Validity Version 2.0 (P) Page 5 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response EMERGENCY GENERATOR SET Automatic Transfer Switch (ATS) Instance Quantity Uom EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Installation Year Source of Installation Year Firetrol Fire Pump Power Transfer Switch 20 HP Nameplate 2008 Documented Deficiency No deficiencies recorded Inspected Battery Charger Instance Lower Roof - Generator Enclosure 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Capacity/Size 2 Quantity Capacity/Size 2 UOM Source of Capacity/Size Installation Year Source of Installation Year SENS Battery Charger 10 AmpsDC 24 VDC Nameplate 2008 Documented Deficiency No deficiencies recorded Inspected Diesel Instance Lower Roof - Generator Enclosure 4- Between Fair and Poor Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Capacity/Size 2 Quantity Capacity/Size 2 UOM Capacity/Size 3 Quantity Capacity/Size 3 UOM Source of Capacity/Size Installation Year Source of Installation Year Caterpillar Emergency Generator 438 kVA 350 kW 1,216 Amps Nameplate 2008 Documented Deficiency Deficiency Quantity GENERATOR NOT OPERATIONAL 1 EACH REPAIR PRIORITY 5 LEVEL 6 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Does not exist Natural Gas Inspected EMERGENCY LIGHT/EXIT LIGHT PANEL 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected EMERGENCY LIGHTING Inspected Battery Pack 2- Between Good and Fair Condition Deficiency Mobile Validity Version 2.0 (P) No deficiencies recorded Page 6 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response EMERGENCY LIGHTING Inspected Non Battery Pack 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected EXIT LIGHT Inspected Battery Pack 2- Between Good and Fair Condition Deficiency Deficiency Location/Instance Deficiency Quantity FIXTURE NOT OPERATIONAL Corridor Near Room 116C 1 EACH REPAIR PRIORITY 5 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected Non Battery Pack 2- Between Good and Fair Condition Deficiency No deficiencies recorded EXIT/EMERGENCY LIGHT Does not exist FIRE ALARM SYSTEM Inspected Area Smoke Detector Inspected 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Bell/Horn 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Duct Smoke Detector 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Elevator Recall 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Fan Shutdown Control 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Fire Alarm Digital Communicator Instance Room 116B 3- Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Installation Year Source of Installation Year Ademco Fire Alarm Communicator 5 Zones Nameplate 2008 Documented Deficiency Deficiency Quantity NOT CONNECTED TO CENTRAL STATION 1 EACH REWIRE PRIORITY 5 LEVEL 6 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected Fused Cutout Panel Mobile Validity Version 2.0 (P) Page 7 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response FIRE ALARM SYSTEM Fused Cutout Panel Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Heat Detector 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Magnetic Door Holder/Contactor 2- Between Good and Fair Condition Deficiency Deficiency Location/Instance Deficiency Quantity CONTACTOR NOT OPERATIONAL 1st Floor 1 EACH REPLACE PRIORITY 5 LEVEL 6 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected Main Panel Inspected Bell At Panel Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Fire Alarm Control Panel (Electronic) Instance Main Entrance Lobby 2- Between Good and Fair Instance Condition Instance Quantity 1 EACH Instance Quantity Uom EquipmentId Capacity/Size Quantity Capacity/Size UOM Capacity/Size 2 Quantity Capacity/Size 2 UOM Source of Capacity/Size Installation Year Source of Installation Year Siemens MXL Fire Alarm Control Panel 96 Zones 1 Section(s) Inspector Estimate 2008 Documented Deficiency No deficiencies recorded Manufacturer Model Does not exist Fire Alarm Control Panel (Standard) Inspected Manual Pull Station 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Remote Annunciator Display Monitor Does not exist Panel Inspected Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Printer Condition 2- Between Good and Fair Deficiency No deficiencies recorded Does not exist Punch Register Inspected Sprinkler Flow/Air Pressure Switch 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Strobe 2- Between Good and Fair Condition Mobile Validity Version 2.0 (P) Page 8 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response FIRE ALARM SYSTEM Strobe Deficiency No deficiencies recorded Sub-Panel Does not exist Tamper Flow Switch/Chain Inspected 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected GROUNDING SYSTEM 2- Between Good and Fair Condition Deficiency No deficiencies recorded GYMNASIUM Instance on 1st Floor Inspected Instance on 1st Floor Inspected Lighting Lighting Fixture - Fluorescent Inspected Instance on 1st Floor Pendant Mounted Does not exist Instance on 1st Floor Recessed Mounted Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Surface Mounted Does not exist Instance on 1st Floor Lighting Fixture - HID Inspected Instance on 1st Floor Pendant Mounted Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Recessed Mounted Does not exist Instance on 1st Floor Surface Mounted Does not exist Instance on 1st Floor Lighting Fixture - Incandescent Does not exist Instance on 1st Floor Lighting Fixture - LED Does not exist Instance on 1st Floor Local Sound System Instance on 1st Floor Inspected Instance Condition Installation Year Source of Installation Year 2- Between Good and Fair Deficiency No deficiencies recorded 2008 Documented Projection System Does not exist Instance on 1st Floor Scoreboard Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Theater Lighting System Does not exist Instance on 1st Floor Inspected INTERCOM SYSTEM Inspected Elevator Mobile Validity Version 2.0 (P) Page 9 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response INTERCOM SYSTEM Elevator Condition 2- Between Good and Fair Deficiency No deficiencies recorded Does not exist Holding Area KITCHEN/WARMING PANTRY Instance on 1st Floor Inspected Instance on 1st Floor Inspected Lighting Lighting Fixture - Fluorescent Inspected Instance on 1st Floor Pendant Mounted Does not exist Instance on 1st Floor Recessed Mounted Instance on 1st Floor Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Surface Mounted Does not exist Instance on 1st Floor Lighting Fixture - HID Does not exist Instance on 1st Floor Lighting Fixture - Incandescent Does not exist Instance on 1st Floor Lighting Fixture - LED Does not exist Instance on 1st Floor Inspected LAN Inspected Local Distribution Frame (I/LDF) 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Main Equipment Rack (MDF) 2- Between Good and Fair Condition Deficiency No deficiencies recorded LIBRARY Instance on Room 125 Inspected Has LAN/Modem access Yes Instance on Room 125 Inspected Lighting Lighting Fixture - Fluorescent Inspected Instance on Room 125 Pendant Mounted Does not exist Instance on Room 125 Recessed Mounted Instance on Room 125 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Surface Mounted Does not exist Instance on Room 125 Lighting Fixture - HID Does not exist Instance on Room 125 Lighting Fixture - Incandescent Does not exist Instance on Room 125 Lighting Fixture - LED Does not exist Instance on Room 125 Projection System Mobile Validity Version 2.0 (P) Page 10 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response LIBRARY Projection System Instance on Room 125 Does not exist Raceway With Receptacles Does not exist Instance on Room 125 Inspected LIGHTNING PROTECTION 2- Between Good and Fair Condition Deficiency No deficiencies recorded LOCKER ROOM Instance on Rooms 440A, 440B, 342A, 342B Inspected Alternative Use No Instance on Rooms 116D, 116N, 130H, 130K Inspected Alternative Use Yes Instance on Rooms 116C, 116I, 116J Inspected Alternative Use No Instance on Rooms 440A, 440B, 342A, 342B Inspected Instance on Rooms 116D, 116N, 130H, 130K Inspected Instance on Rooms 116C, 116I, 116J Inspected Lighting Lighting Fixture - Fluorescent Instance on Rooms 440A, 440B, 342A, 342B Inspected Instance on Rooms 116D, 116N, 130H, 130K Inspected Instance on Rooms 116C, 116I, 116J Inspected Pendant Mounted Instance on Rooms 440A, 440B, 342A, 342B Does not exist Instance on Rooms 116D, 116N, 130H, 130K Does not exist Instance on Rooms 116C, 116I, 116J Does not exist Recessed Mounted Instance on Rooms 440A, 440B, 342A, 342B Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Rooms 116D, 116N, 130H, 130K Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Rooms 116C, 116I, 116J Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Surface Mounted Instance on Rooms 440A, 440B, 342A, 342B Does not exist Instance on Rooms 116D, 116N, 130H, 130K Does not exist Instance on Rooms 116C, 116I, 116J Does not exist Lighting Fixture - HID Instance on Rooms 440A, 440B, 342A, 342B Does not exist Instance on Rooms 116D, 116N, 130H, 130K Does not exist Instance on Rooms 116C, 116I, 116J Does not exist Lighting Fixture - Incandescent Instance on Rooms 440A, 440B, 342A, 342B Does not exist Instance on Rooms 116D, 116N, 130H, 130K Does not exist Instance on Rooms 116C, 116I, 116J Does not exist Lighting Fixture - LED Instance on Rooms 440A, 440B, 342A, 342B Does not exist Instance on Rooms 116D, 116N, 130H, 130K Does not exist Instance on Rooms 116C, 116I, 116J Does not exist Does not exist MOTOR CONTROL CENTER Mobile Validity Version 2.0 (P) Page 11 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response Inspected MOTOR STARTER/CONTACTOR 2- Between Good and Fair Condition Deficiency Deficiency Location/Instance Deficiency Quantity MOTOR STARTER NOT OPERATIONAL Penthouse 2 EACH REPAIR PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations MULTIPURPOSE ROOM Does not exist PANEL BOARD Inspected Inspected Fused Disconnect Switch Type 2- Between Good and Fair Condition Deficiency No deficiencies recorded Fused Knife Switch Type Does not exist Fused Toggle Switch Type Does not exist Molded Case Circuit Breaker Type Inspected 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected PUBLIC ADDRESS SYSTEM Instance Room 124 2- Between Good and Fair Instance Condition Instance Quantity 1 EACH Instance Quantity Uom Model Telecor II 2008 Documented Installation Year Source of Installation Year Deficiency Deficiency Location/Instance Deficiency Quantity CLOCK NOT OPERATIONAL Corridor Near Rooms 430, 220, 116C, 147 6 EACH REPAIR PRIORITY 3 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Deficiency Deficiency Location/Instance Deficiency Quantity SPEAKER NOT OPERATIONAL Corridors 4 EACH REPAIR PRIORITY 5 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Does not exist SCIENCE DEMO ROOM SCIENCE LAB Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Inspected Has LAN/Modem access Yes Power Panel? Yes Alternative Use No Emergency Gas Shut-Off Valve Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Emergency Shut-Off Power Mobile Validity Version 2.0 (P) Page 12 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response SCIENCE LAB Emergency Shut-Off Power Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Inspected Lighting Lighting Fixture - Fluorescent Inspected Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Pendant Mounted Does not exist Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Recessed Mounted Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Surface Mounted Does not exist Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Lighting Fixture - HID Does not exist Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Lighting Fixture - Incandescent Does not exist Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Lighting Fixture - LED Does not exist Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Power Supply Inspected Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Instructor Unit Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Meter Demonstration Unit Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Student Unit Does not exist Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 Projection System Does not exist Instance on Rooms 237, 241, 331, 335, 339, 431, 435, 439 SCIENCE PREP ROOM Instance on Rooms 239, 333, 337, 433, 437 Inspected Has LAN/Modem access Yes Power Panel? No Alternative Use No Emergency Gas Shut-Off Valve Instance on Rooms 239, 333, 337, 433, 437 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Emergency Shut-Off Power Instance on Rooms 239, 333, 337, 433, 437 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Instance on Rooms 239, 333, 337, 433, 437 Inspected Lighting Lighting Fixture - Fluorescent Inspected Instance on Rooms 239, 333, 337, 433, 437 Mobile Validity Version 2.0 (P) Page 13 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response SCIENCE PREP ROOM Lighting Lighting Fixture - Fluorescent Pendant Mounted Does not exist Instance on Rooms 239, 333, 337, 433, 437 Recessed Mounted Instance on Rooms 239, 333, 337, 433, 437 Inspected Instance Condition 2- Between Good and Fair Deficiency No deficiencies recorded Surface Mounted Does not exist Instance on Rooms 239, 333, 337, 433, 437 Lighting Fixture - HID Does not exist Instance on Rooms 239, 333, 337, 433, 437 Lighting Fixture - Incandescent Does not exist Instance on Rooms 239, 333, 337, 433, 437 Lighting Fixture - LED Does not exist Instance on Rooms 239, 333, 337, 433, 437 Power Supply Does not exist Instance on Rooms 239, 333, 337, 433, 437 Inspected SECURITY Intrusion Alarm System Inspected Central Control Panel Inspected Instance Room 210 - Custodian's Office 2- Between Good and Fair Instance Condition Instance Quantity 1 EACH Instance Quantity Uom Model Installation Year Source of Installation Year Vista - 128B 2008 Documented Deficiency No deficiencies recorded Inspected Infrared Sensor Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Panic Switch Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Remote Annunciator Condition 2- Between Good and Fair Deficiency No deficiencies recorded Inspected Siren/Strobe Condition 2- Between Good and Fair Deficiency No deficiencies recorded Does not exist Ultrasonic Sensor Inspected IPDVS/CCTV System 2- Between Good and Fair Condition Installation Year Source of Installation Year 2008 Documented Deficiency No deficiencies recorded Inspected Lighting - Security Condition 2- Between Good and Fair Replacement Quantity Replacement Uom 81 EACH Deficiency No deficiencies recorded Inspected SERVICE SWITCH Mobile Validity Version 2.0 (P) Page 14 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response SERVICE SWITCH Instance Room 120 2- Between Good and Fair Instance Condition Instance Quantity 1 EACH Instance Quantity Uom Installation Year Source of Installation Year Electrotech DBL 1200 Amps Nameplate 2008 Documented Deficiency No deficiencies recorded Instance Room 120 2- Between Good and Fair Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Installation Year Source of Installation Year Electrotech HDBH-A 1200 Amps Nameplate 2008 Documented Deficiency No deficiencies recorded Instance Room 120 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Installation Year Source of Installation Year Electrotech HDBH-B 2500 Amps Nameplate 2008 Documented Deficiency No deficiencies recorded SWIMMING POOL Does not exist SWITCHBOARD Water Penetration In Electrical Room? Number of Spares Inspected Air Circuit Breaker Type Yes 3 Does not exist Fused Disconnect Switch Type Inspected Instance Room 118 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Capacity/Size 2 Quantity Capacity/Size 2 UOM Source of Capacity/Size Installation Year Source of Installation Year Electrotech EMDBH 400 Amps Total 1 Section(s) Service Switch Size 2008 Documented Deficiency SWITCHBOARD NAME PLATE IS MISSING Mobile Validity Version 2.0 (P) Page 15 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response SWITCHBOARD Fused Disconnect Switch Type Deficiency Quantity 1 EACH MAINTENANCE PRIORITY 2 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Instance Room 120 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Capacity/Size 2 Quantity Capacity/Size 2 UOM Source of Capacity/Size Installation Year Source of Installation Year Electrotech DBH 1000 Amps Total 1 Section(s) Nameplate 2008 Documented Deficiency No deficiencies recorded Instance Room 120 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Capacity/Size 2 Quantity Capacity/Size 2 UOM Source of Capacity/Size Installation Year Source of Installation Year Electrotech HDBH-A 1000 Amps Total 1 Section(s) Nameplate 2008 Documented Deficiency No deficiencies recorded Instance Room 120 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Capacity/Size 2 Quantity Capacity/Size 2 UOM Source of Capacity/Size Installation Year Source of Installation Year Electrotech Dist. SWBD HDBH-B 1200 Amps Total 2 Section(s) Nameplate 2008 Documented Deficiency No deficiencies recorded Instance Room 120 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Electrotech CDB Section 1 And 2 800 Mobile Validity Version 2.0 (P) Page 16 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response SWITCHBOARD Fused Disconnect Switch Type Capacity/Size UOM Capacity/Size 2 Quantity Capacity/Size 2 UOM Source of Capacity/Size Installation Year Source of Installation Year Amps Total 2 Section(s) Nameplate 2008 Documented Deficiency No deficiencies recorded Instance Room 120 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Capacity/Size 2 Quantity Capacity/Size 2 UOM Source of Capacity/Size Installation Year Source of Installation Year Electrotech DBL 1000 Amps Total 3 Section(s) Nameplate 2008 Documented Deficiency No deficiencies recorded Fused Knife Switch Type Does not exist Molded Case Circuit Breaker Type Does not exist Inspected TELEPHONE SYSTEM Inspected PBX/Intercom 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected Standard 2- Between Good and Fair Condition Deficiency No deficiencies recorded Inspected TOILET ROOM - STAFF Inspected Lighting Inspected Lighting Fixture - Fluorescent Pendant Mounted Does not exist Recessed Mounted Inspected 2- Between Good and Fair Condition Deficiency No deficiencies recorded Does not exist Surface Mounted Lighting Fixture - HID Does not exist Lighting Fixture - Incandescent Does not exist Lighting Fixture - LED Does not exist Inspected TOILET ROOM - STUDENT Inspected Lighting Inspected Lighting Fixture - Fluorescent Pendant Mounted Does not exist Recessed Mounted Inspected 2- Between Good and Fair Condition Deficiency No deficiencies recorded Does not exist Surface Mounted Lighting Fixture - HID Does not exist Lighting Fixture - Incandescent Does not exist Lighting Fixture - LED Does not exist Inspected TRANSFORMER Instance Mobile Validity Version 2.0 (P) Room 118 Page 17 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response TRANSFORMER Instance Condition 2- Between Good and Fair Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Installation Year Source of Installation Year Rex Power Magnetics N/A 150 kVA Nameplate 2008 Documented Deficiency Deficiency Quantity TRANSFORMER ID IS MISSING 1 EACH MAINTENANCE PRIORITY 2 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Instance Room 118 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Installation Year Source of Installation Year Rex Power Magnetics Fire Alarm Transformer 30 kVA Nameplate 2008 Documented Deficiency No deficiencies recorded Instance Room 120 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Installation Year Source of Installation Year Rex Power Magnetics N/A 300 kVA Nameplate 2008 Documented Deficiency Deficiency Quantity TRANSFORMER ID IS MISSING 1 EACH MAINTENANCE PRIORITY 2 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Instance Room 120, Penthouse 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 2 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Rex Power Magnetics N/A 45 kVA Nameplate Mobile Validity Version 2.0 (P) Page 18 of 19 Print Date: 6/18/2015 NYC Department of Education Building Condition Assessment Survey 2014-2015 Electrical Inspection X362 Question Response TRANSFORMER Installation Year Source of Installation Year 2008 Documented Deficiency Deficiency Quantity TRANSFORMER ID IS MISSING 2 EACH MAINTENANCE PRIORITY 2 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Instance Room 120 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Installation Year Source of Installation Year Rex Power Magnetics N/A 750 kVA Nameplate 2008 Documented Deficiency Deficiency Quantity TRANSFORMER ID IS MISSING 1 EACH MAINTENANCE PRIORITY 2 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Instance Room 121 2- Between Good and Fair Instance Condition Instance Quantity Instance Quantity Uom 1 EACH Manufacturer EquipmentId Capacity/Size Quantity Capacity/Size UOM Source of Capacity/Size Installation Year Source of Installation Year Rex Power Magnetics N/A 113 kVA Nameplate 2008 Documented Deficiency Deficiency Quantity TRANSFORMER ID IS MISSING 1 EACH MAINTENANCE PRIORITY 2 LEVEL 2 No violations recorded Quantity Uom Potential Action Urgency of Action Purpose of Action Violations Inspected TV SYSTEM Cable System Exist? Operational? Yes Yes Inspected Main Equipment Rack 2- Between Good and Fair Condition Deficiency Mobile Validity Version 2.0 (P) No deficiencies recorded Page 19 of 19 Print Date: 6/18/2015