A 1 2 3 4 Item Number Quanity 1 1 6 7 8 C D Description E F G H J K L M N P R S T U V ZONE Wt Pump 8x8X13 VIP w/ Motor Frame 324 - 404 1221 lbm 1 Pump Stand 8 x 8 x 13 VIP x 13 1/4" LG 103 lbm 3 1 Firetrol Controller FTA 1930 351 lbm 4 1 Firetrol FTA500 41 lbm 5 1 Grundfos Jockey Pump CR 3-7 61 lbm 6 1 Main Distribution Panel 60" x 20" x 6" 80 lbm 7 1 Hammond Transformer 7.5 kVA 152 lbm 8 2 Overhead Light 4' x 1' 117 lbm 9 2 Sprinkler Head 0 lbm 10 1 Double Door 6ft (Trachte Building) 222 lbm 11 1 Emergency Light 3 lbm 12 1 Light Switch Wall Mount 0 lbm 1 Electrical Outlet 0 lbm 14 1 Exhaust Fan 24" 57 lbm 15 2 Heater (Standard) 134 lbm 16 1 Motorized Louver / Damper 30" 24 lbm 17 1 Exterior Light 12 lbm 18 1 VLV GATE 8" FLG 150# 248 lbm 19 2 VLV CHECK 8" WFR #KW-900-W 250 PSI 92 lbm 20 4 VLV BFLY 8" #LD3510-8 250# PSI 220 lbm 21 1 Valve Rls Air 1/4" #FV-4M Watts 1 lbm 22 1 VLV CHECK 4" WFR #KW-900-W 250 PSI 11 lbm 23 1 Hose Valve Header 8" Flanged 150 lbs. 117 lbm 24 1 Fire Department Conn. 4" 22 lbm 25 1 Skid Structure W12 x 26# 120" x 168" Lg 2678 lbm 26 1 Trachte Building 120" x 168" (96" Ceiling Height) 2853 lbm W REV ECR 1 NOTES: 2 13 5 B 1: ANCHOR BOLT HOLES AVAILABLE ONLY UPON CUSTOMER REQUEST. X DATE 29397 BY 7-09-10 KM 1 10 2: IF THERE IS A DRAIN OR ANY OTHER OBSTRUCTION IN THE FLOOR THAT SHOULD BE CONSIDERED, PLEASE LOCATE IT ON THIS DRAWING. 106.00 2692.4 54.00 1371.6 17 2 3: THIS SKID IS DESIGNED TO BE FILLED WITH CONCRETE AT INSTALLATION. THE BASE PLATE (UNDER THE PUMP AND DRIVER) IS TO BE GROUTED PER INSTRUCTIONS IN THE 0 & M MANUALS SENT WITH THE UNIT, IF DECKPLATE IS USED OMIT NOTE #3. 12 13 4: DUE TO VARIATIONS IN THE PIPE FITTINGS, CUSTOMER PIPE CONNECTION LOCATIONS MAY VARY +/- 1/2 ". IT IS RECOMMENDED THAT PIPING NOT BE ANCHORED RIGIDLY UNTIL FINAL FIT-UP IS COMPLETE. 7 3 11 3 16 6 5: TAMPER SWITCHES ARE PROVIDED ON ALL BUTTERFLY VALVES, WIRING OF THESE SWITCHES WILL BE BY OTHERS. 6: IF APPLICABLE BUILDING HEATER, EMERGENCY LIGHT, LIGHTS, JOCKEY PUMP CONTROL PANEL, JOCKEY PUMP, AND OTHER ITEMS THAT MAY' BE DIMENSIONED IN PARENTHESIS ( ), ARE SHOWN IN THEIR GENERAL REPECTIVE LOCATIONS AND MAY VARY SLIGHTLY FROM THE LOCATION SHOWN ON THE DRAWING. 8 120.00 3048.0 8 9 4 9 4 99.75 2533.7 15 7: ELECTRICAL SERVICE TO BE LANDED BY OTHERS IN DISTRIBUTION PANEL PROVIDED WITH BUILDING. 82.00 2082.8 8: CASING RELIEF VALVE DISCHARGE DRAIN IS NOT PLUMBED UNLESS SPECIFIED BY CUSTOMER. 9: THE LINE BELOW IS 12" LONG ON THE ORIGINAL DRAWING, USE THIS LINE TO MAKE SCALING ADJUSTMENTS WHEN INQUIRING ON LENGTHS. B 47.75 1212.9 35.00 889.0 F A 35.00 889.0 22 5 12.00 304.8 F 113.25 2876.6 15 6 14 24 23 23.25 590.6 5 71.75 1822.5 7 133.75 3397.3 8 Ceiling Height 96.00" 9 19 9 21 20 10 10 20 20 11 20 18 1 87.10 2212.2 11 C D 57.97 1472.4 26 37.47 951.7 28.47 723.1 12 12.22 310.4 19 2 A 25 G H H 120.00 3048.0 13 168.00 4267.2 Connection Table Letter A 15 Description Approx. Dry Weight: 10450 lbm Letter Suction Connection 8" 150# FF Description E Discharge Connection 8" 150# FF F Ball Drip Valve 1/2" NPT C Jockey Pump Conn. Suction Side 1 1/4" NPT G Packing Drain Discharge 1" NPT R PATTERSON PUMP COMPANY PPC ORDER # A B C D E F G Jockey Pump Conn. Discharge Side 1 1/4" NPT H J K H Lifting Points - Pipe 6" Sch 40 L M D03-116833 General Arrangement 8 x 8 x 13A w/ 365 JPV DRAWN SCALE N P R S T U V 6/29/2010 APPRVD. 1:20 C097496 1 DATE kmcpherson A SUBSIDIARY OF THE GORMAN-RUPP COMPANY 14 REV. DWG. NO. Sensing Line Connection 1/2" NPT B D 12 5.00 127.0 Typ. 78.00 1981.2 14 37.47 28.47 951.7 723.1 B 36.00 914.4 13 55.60 1412.1 E W TS X 15