patterson pump company

advertisement
A
1
2
3
4
Item
Number
Quanity
1
1
6
7
8
C
D
Description
E
F
G
H
J
K
L
M
N
P
R
S
T
U
V
ZONE
Wt
Pump 8x8X13 VIP w/ Motor Frame 324 - 404 1221 lbm
1
Pump Stand 8 x 8 x 13 VIP x 13 1/4" LG
103 lbm
3
1
Firetrol Controller FTA 1930
351 lbm
4
1
Firetrol FTA500
41 lbm
5
1
Grundfos Jockey Pump CR 3-7
61 lbm
6
1
Main Distribution Panel 60" x 20" x 6"
80 lbm
7
1
Hammond Transformer 7.5 kVA
152 lbm
8
2
Overhead Light 4' x 1'
117 lbm
9
2
Sprinkler Head
0 lbm
10
1
Double Door 6ft (Trachte Building)
222 lbm
11
1
Emergency Light
3 lbm
12
1
Light Switch Wall Mount
0 lbm
1
Electrical Outlet
0 lbm
14
1
Exhaust Fan 24"
57 lbm
15
2
Heater (Standard)
134 lbm
16
1
Motorized Louver / Damper 30"
24 lbm
17
1
Exterior Light
12 lbm
18
1
VLV GATE 8" FLG 150#
248 lbm
19
2
VLV CHECK 8" WFR #KW-900-W 250 PSI
92 lbm
20
4
VLV BFLY 8" #LD3510-8 250# PSI
220 lbm
21
1
Valve Rls Air 1/4" #FV-4M Watts
1 lbm
22
1
VLV CHECK 4" WFR #KW-900-W 250 PSI
11 lbm
23
1
Hose Valve Header 8" Flanged 150 lbs.
117 lbm
24
1
Fire Department Conn. 4"
22 lbm
25
1
Skid Structure W12 x 26# 120" x 168" Lg
2678 lbm
26
1
Trachte Building 120" x 168" (96" Ceiling
Height)
2853 lbm
W
REV
ECR
1
NOTES:
2
13
5
B
1: ANCHOR BOLT HOLES AVAILABLE ONLY UPON CUSTOMER REQUEST.
X
DATE
29397
BY
7-09-10
KM
1
10
2: IF THERE IS A DRAIN OR ANY OTHER OBSTRUCTION
IN THE FLOOR THAT SHOULD BE CONSIDERED, PLEASE LOCATE
IT ON THIS DRAWING.
106.00
2692.4
54.00
1371.6
17
2
3: THIS SKID IS DESIGNED TO BE FILLED WITH CONCRETE AT
INSTALLATION. THE BASE PLATE (UNDER THE PUMP AND DRIVER)
IS TO BE GROUTED PER INSTRUCTIONS IN THE 0 & M MANUALS
SENT WITH THE UNIT, IF DECKPLATE IS USED OMIT NOTE #3.
12 13
4: DUE TO VARIATIONS IN THE PIPE FITTINGS, CUSTOMER PIPE
CONNECTION LOCATIONS MAY VARY +/- 1/2 ". IT IS RECOMMENDED
THAT PIPING NOT BE ANCHORED RIGIDLY UNTIL FINAL FIT-UP IS
COMPLETE.
7
3
11
3
16
6
5: TAMPER SWITCHES ARE PROVIDED ON ALL BUTTERFLY VALVES,
WIRING OF THESE SWITCHES WILL BE BY OTHERS.
6: IF APPLICABLE BUILDING HEATER, EMERGENCY LIGHT, LIGHTS, JOCKEY
PUMP CONTROL PANEL, JOCKEY PUMP, AND OTHER ITEMS THAT MAY'
BE DIMENSIONED IN PARENTHESIS ( ), ARE SHOWN IN THEIR GENERAL
REPECTIVE LOCATIONS AND MAY VARY SLIGHTLY FROM THE
LOCATION SHOWN ON THE DRAWING.
8
120.00
3048.0
8
9
4
9
4
99.75
2533.7
15
7: ELECTRICAL SERVICE TO BE LANDED BY OTHERS IN DISTRIBUTION PANEL
PROVIDED WITH BUILDING.
82.00
2082.8
8: CASING RELIEF VALVE DISCHARGE DRAIN IS NOT PLUMBED UNLESS
SPECIFIED BY CUSTOMER.
9: THE LINE BELOW IS 12" LONG ON THE ORIGINAL DRAWING, USE THIS
LINE TO MAKE SCALING ADJUSTMENTS WHEN INQUIRING ON LENGTHS.
B
47.75
1212.9
35.00
889.0
F
A
35.00
889.0
22
5
12.00
304.8
F
113.25
2876.6
15
6
14
24
23
23.25
590.6
5
71.75
1822.5
7
133.75
3397.3
8
Ceiling Height 96.00"
9
19
9
21
20
10
10
20
20
11
20
18
1
87.10
2212.2
11
C
D
57.97
1472.4
26
37.47
951.7
28.47
723.1
12
12.22
310.4
19
2
A
25
G
H
H
120.00
3048.0
13
168.00
4267.2
Connection Table
Letter
A
15
Description
Approx. Dry Weight: 10450 lbm
Letter
Suction Connection 8" 150# FF
Description
E
Discharge Connection 8" 150# FF
F
Ball Drip Valve 1/2" NPT
C
Jockey Pump Conn. Suction Side 1 1/4" NPT
G
Packing Drain Discharge 1" NPT
R
PATTERSON PUMP COMPANY
PPC ORDER #
A
B
C
D
E
F
G
Jockey Pump Conn. Discharge Side 1 1/4" NPT
H
J
K
H
Lifting Points - Pipe 6" Sch 40
L
M
D03-116833
General Arrangement
8 x 8 x 13A w/ 365 JPV
DRAWN
SCALE
N
P
R
S
T
U
V
6/29/2010
APPRVD.
1:20
C097496
1
DATE
kmcpherson
A SUBSIDIARY OF THE GORMAN-RUPP COMPANY
14
REV.
DWG. NO.
Sensing Line Connection 1/2" NPT
B
D
12
5.00
127.0
Typ.
78.00
1981.2
14
37.47
28.47 951.7
723.1
B
36.00
914.4
13
55.60
1412.1
E
W
TS
X
15