WHOLESALER CATALOGUE THE EMERGENCY LIGHTING SPECIALISTS LIGHTING THE WORLD FOR OVER 25 YEARS THE EMERGENCY LIGHTING SPECIALISTS Ventilux designs, manufactures and offers an extensive range of safety system products and services, including Emergency Lighting, Central Battery Systems, Luminaire Conversion Equipment, Nurse Call, Emergency Lighting Commissioning, Service and Maintenance. Ventilux was founded in 1985, and has since grown steadily to become one of the largest Independent Emergency Lighting Manufacturers in Europe & the Middle East. The Head Office at Dun Laoghaire, South Dublin, Ireland, is the centre of the Ventilux operation, with over 15,000 sq. ft. of state-of-the-art production facilities, research and development laboratories, in house training centre and global distribution warehouse. Liverpool is the UK base for distribution, sales order processing and in-house conversions. Ventilux operate, and are certified to, ISO:9001:2008. EMERGENCY LIGHTING CENTRAL BATTERY SYSTEMS LUMINAIRE CONVERSION EQUIPMENT EMERGENCY LIGHTING COMMISSIONING SERVICE AND MAINTENANCE BESPOKE PRODUCT NURSE CALL VENTILUX Quality Service SYSTEM DESIGN SERVICE A team of qualified system engineers are permanently on hand at our design centres in Dublin and Liverpool, ready to help in every aspect of system design. Using the latest computer aided techniques, qualified staff are able to prepare schemes and provide quotations quickly and efficiently. QUALITY All Products bearing the Ventilux logo are CE marked, EMC compliant and manufactured and tested to the highest standards. So confident are we of our quality systems and testing procedures, we offer a 3 year warranty as standard on the majority of Ventilux manufactured products. MANUFACTURE & DESIGN New product development coupled with continuous refinement of existing product design have been essential elements of the company’s success. Modern manufacturing technology combined with stringent quality control ensures that Ventilux products provide the customer with top quality and excellent value for money. All products are manufactured to the appropriate European Standards and each unit is fully tested and inspected prior to dispatch. CONVERSIONS Ventilux offer a complete conversion service at our sites in Dublin & Liverpool, where the converted luminaires are CE marked and undergo full thermal and EMC testing. DISTRIBUTION Ventilux products are readily available both in Ireland and the UK through a nationwide network of electrical wholesale distributors. To support our distributors, Ventilux keeps exceptionally high levels of finished stock at both Dublin and Liverpool, ready for immediate dispatch. Our Export department at Dublin provides worldwide support to a network of Distributors and Agents in all 5 continents and are able to provide advice on domestic and international requirements. 3 Exit Signage Escape Route Lighting Economy Range Contents ECONOMY BOX EXIT pg12 SOLARIS pg14 ECONOMY TWINSPOT pg14 SOLARIS OPTIC LED pg16 MOUNTED SIRIUS LED pg20 SOLAS HORIZON OPTIC SURFACE pg12 VISOR pg17 HALO LED pg21 GALAXY RANGE pg13 EVOLUX pg13 pg14 ECONOMY TWINSPOT pg14 pg18 EYECON LED pg22-23 NOVA SQUARE NOVA CIRCULAR pg25 WEATHERPROOF pg26 WEATHERLUX pg27 VISION TRIMLITE pg29 VERSE pg30 VANTAGE pg31 ECLIPSE RANGE pg19 pg24 pg28 pg32-33 EXLUX pg38 EXLUX PLUS pg39 VASARI pg40 GLADE pg41 STYLUX pg42 STYLUX RECESSED pg43 FOCAL pg44 ECLIPSE DUAL pg45 4 EXLUX IP67 pg51 SCOUT pg54 CORONA INDEPENDENT LED CONVERSION MODULE pg60 MAINS LED LED MR16 CONVERSION PACK pg64 CONVERTALUX pg55 TWINLUX CONVERSION MODULE STARPACK pg61 CONVERTALUX KPHFM SERIES pg65 CONVERTALUX TH PACK EMERGENCY LIGHTING SYSTEMS G NETCOM 5XP G STATIC INVERTER/CBS G CENTRAL TEST UNITS DESIGNERS’ INFORMATION SERVICE & MAINTENANCE GLOSSARY FIRE PROTECTION EQUIPMENT PG69-72 PG70-71 PG72 PG72 PG73-82 PG83-85 PG86-87 PG 95 5 pg50 pg56-57 COMPACT TWIN LAMP pg58 pg62 CONVERTALUX pg63 KPT5 SERIES pg66 CONVERTALUX QUICK pg67 PACK & CEM SERIES Twinspot & Tungsten Halogen Lighting pg46-47 VISTA SINGLE-SIDED pg48 VISTA DOUBLE-SIDED pg49 VISAGE Emergency Conversion Power Packs VANGUARD Exit Signage Continued. Contents Some of our clients: DUBLIN AIRPORT (IRELAND) Not only is Dublin Airport Ireland’s busiest airport it is also amongst the ten busiest airports in Europe. Dublin Airport manages an average of 60,000 passengers per day, rising to 80,000 during the peak season. Due to the size of the buildings Ventilux were asked to install our Netcom5XP addressable testing system. Netcom 5XP (Page 70) can monitor over 25,000 luminaires from one central location (PC or Laptop). This installation resulted in considerable savings for Dublin Airport as it substantially reduced the labour costs associated with Emergency Lighting Testing. AVIVA STADIUM (IRELAND) The Aviva Stadium is a sports stadium located in Dublin, Ireland, with a capacity for over 50,000 spectators. It is commonly known as Lansdowne Road. The original multi discipline ground was in existence at the Lansdowne Road site since 1872. In its old incarnation, prior to closure in December 2006, it was the oldest rugby union ground worldwide & the oldest sports stadium in Europe. Due to the size of the site and also the numbers of spectators the venue would welcome on match day or for a concert, Ventilux Static Inverters were installed to reduce the power consumption costs associated with self contained fittings. LIVERPOOL ONE DEVELOPMENT (ENGLAND) Liverpool One was a major new development in the heart of Liverpool city centre. It comprised of 30 major new buildings including 2 department stores, banks, hotels, restaurants and luxury residential accommodation in 42 acres between Liverpool City Centre and the Albert Dock. The site required over 4,500 Ventilux Emergency Conversions Packs (Page 59) In what is believed to be the largest emergency lighting installation in Europe with centralised monitoring and testing facilities, Ventilux supplied emergency luminaires, central battery systems and a central test and monitoring system. COCA-COLA ENTERPRISES (ENGLAND) In Kent, England Coca-Cola Enterprises produce small plastic bottles, recyclable glass and cans across a variety of products including Schweppes Cordial, Roses, 5 Alive, Ki-Ora and the Coke Contour bottle. Built in 1961, the plant now produces over 800 million drinks every year. As part of a major cost saving project, Ventilux managed the installation of a Static Inverter System to power over 500 LED luminaires including signage and open area luminaires. Coca Cola chose over 500 ‘Halo LED’ luminaires to dramatically reduce the power consumption on site. The ‘HALO LED’ also gave our client 10 times the lamp life of their previous installation, resulting in huge immediate and long term cost savings. INTERCONTINENTAL HOTEL DOHA (QATAR) The Intercontinental Hotel in Doha Qatar is a beautifully designed building incorporating nine floors, five of which house the 400 rooms. One of the floors has a choice of 3 restaurants and a buffet restaurant. The basement hosts a 150sqm Gymnasium, sauna, jacuzzi, and steam room. Outside there is a swimming pool and a pool bar. Ventilux Limited supplied our GLADE and FOCAL products on this project as the Hotel wanted a discrete yet stylish Emergency Lighting installation. ABU DHABI NATIONAL OIL COMPANY (ABU DHABI) A.D.N.O.C. is the Abu Dhabi National Oil Company. The project consisted of supplying between 25 and 75 Petrol Stations throughout Abu Dhabi over 3 years. All fittings were supplied the same throughout the installations to maintain a corporate image. Ventilux decided with the customer that the Weatherlux and the Stylux fittings were the most suitable. The Stylux Range was chosen for its durability and aesthetic appearance, whilst the Weatherlux was chosen for its vandal resistance and IP rating. 6 Made for you... DESIGN TEAM VENTILUX prides itself on its flexible Engineering Design Department. This department consists of technical expert engineers all highly trained graduates dedicated to developing cost effective Emergency Lighting designs. Our design experts plan, budget and design for client specific requirements. Our design team utilise various state-of-the-art design software packages to ensure quality and compliance in our Emergency Lighting designs. Ventilux also has the ability to Project Manage small, medium and large projects from design phase, to commissioning and handover. We have specialist engineers to provide technical assistance at all times to ensure complete peace of mind. TAILOR-MADE PRODUCTS VENTILUX have more than 25 years experience tailoring our products to the needs of our customers. From design tweaks and logo additions, to the ground-up construction of a new product to meet a niche need, we can provide lighting solutions that suits your requirements perfectly. We can modify our extensive range of existing products to better suit your needs, or work with you to custom-make lights to meet your requirements. We’ve manufactured lights from standard finishes like brass and chrome to blue, green, red and even pink! for customers who require that personalised touch. Ventilux also offer a vast range of voltages for varying countries throughout the world. So if you have a project that requires a unique product, or a certain colour talk to us! 7 Cost Saving Features LED- LIGHT EMITTING DIODE The operational life of the Ventilux LED's used in our products is 50,000 hours. This equates to approximately five and a half years continuous operation. This is in stark contrast to the expected life of a conventional 8 watt fluorescent lamp, which is approximately 5,000 hours. With fluorescent lamps, the true cost of the lamp is the cost of replacement lamp plus the labour expense and time needed to replace them - which can be considerable. These costs are significant factors with ever increasing operational costs, especially where there are a large number of installed luminaires. Another key strength of the Ventilux LED range is the reduced power consumption of the LED emergency module. The LED module charges the Ni-Mh battery typically at 15- 25% power consumption compared to a conventional Ni-Cd charger. 300 SERIES 300 SERIES A conventional 8 watt escape route luminaire will give approximately 80-90 lumens (light output) in Emergency condition. With Cree LED's, Ventilux can offer up to an impressive 300 lumens in Emergency! Therefore in certain applications instead of installing 4 bulkheads for example, you would only need 1 of our 300 Series luminaires! This provides our customers with fantastic initial and long term cost savings. As you can imagine, installing less fittings, replacing less batteries and extending lamp life will lead to significant savings. Just look for the 300 Series logo in our product guide for this cost saving feature. KEEP IT GREEN In addition to the cost savings the Ventilux LED product range offers, the product range also offers the client an environmentally friendly emergency lighting solution. Nickel-metal hydride (Ni-Mh) batteries are commonly considered to have lower environmental impact than conventional nickel cadmium (Ni-Cd) batteries, due to the absence of toxic cadmium, LED's have a further environmental advantage in that they contain no environmentally hazardous mercury, unlike fluorescent lamps. 8 Cost Saving Features VENTILUX AUTO-TEST MODULE The Ventilux Auto-Test feature is a stand-alone integral testing solution for small to medium size installations. The Auto-Test module is able to perform a test sequence and report the health of the battery, lamp or charger via a Tri-Colour LED. Pre-programmed to the testing requirements of EN50172 the Auto-Test module offers a cost competitive solution and peace of mind where automated testing is concerned. *For a Ventilux Auto Test function please specify /AT WHAT ARE THE FEATURES? • Maintained and non-maintained functionality selectable on the module. • Optional audible alarm if required. • Capable of tracking and storing day count. • Built-in pre-start sequence to ensure not all emergency luminaire test at the same time ensuring that the emergency lighting installation will always have emergency light coverage. • Countdown feature via Tri-Colour LED to indicate when full duration test will occur. • Optional Push Test function to perform functional test. *Please specify /PT VENTILUX MICROWAVE SENSOR The Ventilux Microwave Sensor is ideally suited to commercial applications such as shops and offices, in areas where lighting can be left on. It is also suitable for store room, toilet applications or any other room where lighting may accidentally be left turned on. The Ventilux Microwave Sensor uses ultra-high frequency radio waves known as microwaves, and the principle of the Doppler Effect to detect motion. The Microwave Sensor will stay on as long as it detects movement within its range of sensitivity. HOW DOES IT WORK? The Microwave Sensor sends out radio waves that bounce off nearby surfaces and return to the sensor. Motion in the area changes the speed of the waves returning to the sensor. The sensor detects the change and interprets it as occupancy. This causes the sensor to turn ON the luminaire. High frequency radio waves can penetrate certain materials, therefore the microwave sensor can be installed behind a luminaire diffuser and therefore offer a big advantage over conventional PIR switches which require a line of sight to function correctly. WILL I SAVE MONEY? The energy savings will be extremely high with a very short payback with this small compact and easy to install module. With a range of up to 10 meters, multi units can be used in offices and corridors to reduce long term operational costs. Just imagine the high costs of leaving luminaires on 365 days a year, 24 hours a day. Why not integrate a Ventilux Movement Sensor and start saving money today! *For a Ventilux Movement Sensor please specify /MWS 9 Escape Route Lighting New Products OPTIC LED SURFACE MOUNTED The Optic Surface Mounted LED is specifically designed to complement the Optic LED range and offers a cohesive escape route and open plan emergency lighting solution for applications where recessing into the ceiling is not an option. Customers have found stair cores, in particular, an area where recessing is just not possible. The OPTIC LED SURFACE MOUNTED version is a cost effective and environmentally friendly solution to this problem. (Page 17) SCOUT LED Purpose designed for interior use, the Scout LED luminaire houses a unique’ swivel and rotate system, which allows independent positioning of the projectors, giving the installer more flexibility on installation. The 6 WATT CREE LED'S once again offer reduced power consumption compared to the standard 20 or 55watt Tungsten Halogen lamp. (Page 54) EYECON LED The Eyecon LED is a discrete and unobtrusive LED Escape Route and Open Plan Emergency Lighting solution. The Eyecon LED offers an even lower power consumption than a 3 Watt, consuming just 1 Watt. Please refer to page 19 to see the savings this luminaire offers compared to a conventional 8 watt luminaire. SIRIUS LED By functioning as both a mains and emergency LED driver, the Sirius LED luminaire provides an environmentally friendly, long life and economically viable alternative to a traditional fluorescent 16, 28 and 38 watt luminaire. In certain applications Ventilux can half our clients energy consumption by offering this easily to maintain LED luminaire. (Page 20) For our EMERGENCY AND MAINS LED CONVERSION PACK for retro-fit refurbishment please refer to Page 67 INDEPENDENT LED CONVERSION MODULE The exceptionally low profile 'Stand Alone' KPLED conversion kit can be fitted inside the latest generation slimline luminaires and offers a cost effective solution to conventional linear fluorescent lamp conversions. For more information on this and more innovative EMERGENCY CONVERSION TECHNOLOGY please refer to Page 59 10 Economy Range 11 ECONOMY BOX EXIT The ECONOMY BOX EXIT sign luminaire is a cost effective, versatile and unobtrusive directional sign product. Designed to satisfy statutory requirements for Exit Signs using panels selected from our comprehensive range, which will correctly indicate the direction of the escape route. The housing provides down light through a carefully designed panel in the lower surface of the luminaire to assist in the illumination of the emergency escape route. Product Code Operation Lamp Battery Lumen IP Rating Weight EBM3/F8 EBM3/LED M M T5-8 Watt LED 2.4V/4.5A/h 3.6V / 1.8A/h 78 70 20 20 1.5kg 1.5kg • • • • Dimensions: 420x200x65 (mm) White finish as standard 36 metre viewing distance White powder coated galvanised steel housing Polycarbonate legend HORIZON Designed for indoor installation in a range of public locations the HORIZON is an ideal cost effective solution where the emphasis is on clear signage and aesthetic appearance. Incorporating the latest LED technology, the HORIZON offers the client long cost savings with respect to operational and maintenance costs. Engineered with ease of installation and cost effectiveness as a focus, the HORIZON achives its goals while offering an exciting aesthetic to rival any edgelit sign luminaire on the market. Please specify / Br (Brass) / CH (Chrome) / WH (White) Product Code Operation Lamp Battery Lumen IP Rating Weight HZM3/LED M LED 3.6V/1.8A/h 70 20 2.5kg • • • • • • Dimensions: 400x250x30 (mm) Chrome, Brass and White as standard 36 metre viewing distance Extruded aluminium body Polycarbonate legend 50,000hrs lamp life 12 VISOR O Designed for indoor and outdoor installation in a range of commercial and industrial locations, the compact Visor Luminaire offers a high level of specification, ease of installation and excellent value for money. IP65 Ease of installation, provided by a hinged mounted geartray and a choice of cable entries, as well as a lens design which maximises light distribution are key factors which make the Visor one of the most exciting and popular luminaires available from Ventilux. Please see below* Product Code Operation Lamp Battery Lumen IP Rating Weight VIM3/F8 VINM3/F8 VIM3/LED VINM3/LED M N-M M N-M T5-8 Watt T5-8 Watt LED LED 2.4V/4.5A/h 2.4V / 4.5A/h 3.6V / 1.8A/h 3.6V / 1.8A/h 78 87 70 70 65 65 65 65 1.5kg 1.2kg 1.2kg 0.9kg • • • • • • • Dimensions: 345x75x120 (mm) White finish as standard 22 metre viewing distance Flame retardant ABS body Polycarbonate diffuser Exit Signage stickers also available *Double-Sided Exit Signage available/DS EVOLUX Specifically designed with the most conventional architects and consultants desires in mind, while maintaining the contractors needs as a priority during installation in prestigious areas. Purpose designed for interior use, the EVOLUX luminaire is designed to fit into a hole of 35mm, and comes in two parts, giving the installer more flexiibility and ease of installation. Product Code Operation Lamp Battery Lumen IP Rating Weight EVONM3/LED N-M LED 3.6V/2.1A/h 75 20 0.6kg • • • • • • • • Dimensions: Lamp Head: 45mmx4mm Charger Body: 165mmx31mm Battery Body: 137mmx31mm Chrome finish as standard Other colours on request 35mm Cut-out 50,000hrs lamp life 13 O SOLARIS IP65 Solaris-the elegantly slim range of emergency and matching mains luminaires from Ventilux is ideal for all prestigious locations, incorporating high efficiency 2D compact fluorescent lamps. Identical housings are used for both emergency lighting and mains lighting versions allowing the same profile to be used throughout an installation. Product Code Operation Lamp Battery Lumen IP Rating Weight SRM3/F282D SRNM3/F282D SR/F282D/240 M N-M Mains 28 Watt 28 Watt 28 Watt 4.8V / 4.5A/h 4.8V / 4.5A/h N/A 191 224 2250 65 65 65 3.1kg 3.1kg 2.5kg • • • • Dimensions: 330 dia x 115 (mm) White finish as standard Flame retardant ABS body Opal Polycarbonate diffuser O ECONOMY TWINSPOT IP65 The Economy Twinspot range of luminaires have been specifically designed to provide a cost effective emergency lighting solution in high bay industrial areas, factories or large warehouses where there is a requirement to project high intensity beams between the racks and equipment to illuminate walkways and assist safe evacuation in case of emergency. *WETLED/NM3 Product Code Operation Lamp Battery Lumen IP Rating Weight ETS20/NM3 ETSLED/NM3 *WETLED/NM3 N-M N-M N-M 2x20 Watt 2x4.8 Watt 2x4.8 Watt 2 x 12V/7.0A/h 2 x 6V/7.0A/h 2 x 6V/7.0A/h 600 240 240 20 20 65 8.3kg 4.3kg 2.3kg • • • • • Dimensions: 305x306x70 (mm) White finish as standard White powder coated steel housing (IP20 Version) 50,000hrs- LED version WETLED/NM3 300x290x68 14 Escape Route Lighting 15 Escape Route Optic LED The Optic LED is specifically designed to offer a cohesive escape route and open plan emergency lighting solution within a specific project, maximising emergency light distribution and offering long term cost savings to the client. 300 SERIES Recessed Available in a dedicated escape route and open plan configuration the Optic LED is designed around the market-leading American manufactured CREE LED. Configured in a 3 x 1 watt configuration, the Optic /Cree combination offers an impressive 300 lumens during emergency operation. Escape route/corridor application Please specify / BL for Black Open plan application Product Code Operation Lamp Battery Lumen VA Weight OPM3/LED/ES OPM3/LED/OP OPNM3/LED/ES OPNM3/LED/OP M M N-M N-M LED LED LED LED 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 300 300 300 300 1.5kg 1.5kg 1.5kg 1.5kg Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hours duration • • • • • • • Lamp head dimensions: 140 x 32 D (mm) Remote housing dimensions: 65mm x 700mm long 50,000 hours lamp life ABS Body complete with IP20 protection White finish as standard. Other colours available on request Also available with NETCOM 5XP or DALI (Page 70) Available with Auto-Test function (Page 9) 16 7 7 3.5 3.5 Escape Route The Optic Surface Mounted LED is specifically designed to complement the Optic LED range and offer a cohesive escape route and open plan emergency lighting solution. Optic LED 300 SERIES Surface Mounted The operational life of the high power CREE LED is 50,000 hours. The long operational life of an LED lamp is in stark contrast to the expected life of a conventional 8 watt fluorescent lamp which is approximately 5000 hours. Escape route/corridor application Open plan application Product Code Operation Lamp Battery Lumen VA Weight OPM3/LED/ES/SM OPM3/LED/OP/SM OPNM3/LED/ES/SM OPNM3/LED/OP/SM M M N-M N-M LED LED LED LED 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 300 300 300 300 1.7kg 1.7kg 1.6kg 1.6kg 8 8 3.5 3.5 Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • Dimensions: 200 L x 200 D x 70 H (mm) 50,000 hours lamp life Powder coated sheet steel housing ABS lamp head complete with IP20 protection White finish as standard. Other colours available on request Also available with NETCOM 5XP or DALI (Page 70) Available with Auto-Test function (Page 9) 17 Please specify / BL for Black Escape Route Purpose designed for interior use, the Halo 3 Watt luminaire is designed to fit into a hole of 38mm, and comes in two parts, giving the installer more flexibility and ease of installation. Halo LED Recessed Designed for indoor installation in a range of public locations the Halo 3 Watt is an ideal, cost effective solution, where the emphasis is on discrete and aesthetic appearance. / PLUS for maintained operation Product Code Operation Lamp Battery HANM3/LED/3W HAM3/LED/PLUS N-M M 4.8V / 2.5A/h 180 4.8V / 2.5A/h 180 LED LED Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • Lamp head dimensions: 45 x 3 depth (mm) Designed to fit into a 38mm diameter hole Designed to fit into a 165mm ceiling void White finish as standard Other colours available on request Also available with NETCOM 5XP (Page 70) Available with Auto-Test (Page 9) 18 Lumen VA 2.1 5.0 Weight 1.0kg 1.5kg Escape Route The Eyecon LED is specifically designed to offer a cohesive surface mounted escape route and open plan emergency lighting solution within a specific project. Eyecon LED The Eyecon LED is designed around the market-leading American manufactured Cree LED. Configured in a single 1watt configuration, the Eyecon/Cree combination offers an impressive 120 lumens during emergency operation. Surface Mounted Please specify /BL for Black Product Code Operation Lamp Battery EYNM3/LED N-M 4.8V / 1.3A/h 120 Emergency luminaire NM 8 watt luminaire EYECON LED Power consumption 5.5 watts 2.3 watts Lumen VA Cost per unit of electricity €0.18 KWh €0.18 KWh Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • 2.3 Dimensions: 140 DIA x 48 H (mm) 50,000 hours lamp life ABS lamp head complete with IP20 protection White finish as standard. Other colours available on request 19 Weight 1.1kg Running cost per fitting (annually) €8.67 / £ 7.53 / $ 11.26 (US) €3.62 / £ 3.14 / $ 4.70 (US) Escape Route Sirius LED 300 SERIES O By functioning as both a mains LED driver and emergency LED driver, the Sirius LED luminaire provides an environmentally friendly, long life and economically viable alternative to a traditional fluorescent luminaire. IP65 Offering light output comparable to a conventional 28 watt 2D fluorescent product, the Sirius LED offers the client an easy opportunity to significantly reduce their carbon footprints for a relatively low initial investment and very quick payback time. The Sirius LED comes complete with a 5 year warranty. Please specify /CH for Chrome Product Code Operation Lamp Battery SIM3/LED SINM3/LED M N-M 4.8V / 4.5A/h 300 4.8V / 4.5A/h 300 LED LED Lumen VA *Please specify /240v after the above code for mains operation *Please specify /NL after the above code for integrated Nightlight Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • • Dimensions: 330mm DIA x 118 H (mm) Flame retardant polycarbonate diffuser and base (IP 65) Opal diffuser as standard. Prismatic diffuser available on request White finish as standard, Please specify /CH (Chrome) /PB (Polished Brass) Other colours available on request Recessing Kit available on request Also available with NETCOM 5XP (Page 70) Available with Ventilux Movement Sensor (Page 9) Available with Auto-Test/Push-Test function (Page 9) 20 16 3 Weight 1500gms 1500gms Escape Route Solas, the elegantly slim range of emergency and matching mains luminaires from Ventilux is ideal for all prestigious locations, incorporating high efficiency 2D compact fluorescent lamps. Solas Comprising an opalescent polycarbonate diffuser, snapped to a polycarbonate base, Solas is an exceptionally low profile emergency lighting luminaire. This is made possible by using a combined high frequency mains ballast and emergency ballast which was pioneered by Ventilux. Product Code Operation Lamp Battery Lumen VA Weight SOM3/F162D SONM3/F162D SOM3/F282D SONM3/F282D SOM3/F382D* SONM3/F382D M N-M M N-M M N-M 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 6.0V / 4.0A/h 6.0V / 4.0A/h 114 134 191 224 210 248 1.65kg 1.6kg 1.65kg 1.6kg 1.8kg 1.75kg 16W 2D 16W 2D 28W 2D 28W 2D 38W 2D 38W 2D •Please specify /240V after the above code for mains operation •Please specify /LED after the above code for LED operation •Please specify /NL after the above code for integrated Nightlight Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • • * Dimensions: 360 DIA x 115 H (mm) Flame retardant polycarbonate diffuser and base (IP 54) Opal diffuser as standard White finish as standard, Please specify /CH (Chrome) /PB (Polished Brass) Other colours available on request Recessing Kit available on request Also available with NETCOM 5XP or DALI Addressable (Page 70) Available with Ventilux Movement Sensor (Page 9) Available with Auto-Test/Push-Test function (Page 9) Denotes 1 year warranty 21 33.5 7.6 39.7 7.6 40.9 7.6 Escape Route The Galaxy range is a discreet, robust and stylish polycarbonate emergency and mains luminaire with snap fit diffusers. O Galaxy Square IP65 Complemented with a matching range of square units. Ideal for all projects where a high quality, low budget luminaire is required. Ideal for office, hotel and outdoor environments. Product Code Operation Lamp Battery Lumen VA Weight GSM3/F162D GSNM3/F162D GSM3/F282D GSNM3/F282D *GSM3/F382D GSNM3/F382D M N-M M N-M M N-M 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 6.0V / 4.0A/h 6.0V / 4.0A/h 114 134 191 224 210 248 2.3kg 2.0kg 2.4kg 2.1kg 2.4kg 2.1kg 16W 2D 16W 2D 28W 2D 28W 2D 38W 2D 38W 2D 33.5 8 39.7 8 40.9 7.6 *Please specify /240V after the above code for mains operation *Please specify /LED after the above code for LED operation 300 83mm Square Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • Dimensions: 300 x 300 x 83 (mm) Flame retardant polycarbonate diffuser and base (IP 65) White finish as standard. Other colours on request Also available with NETCOM 5XP or DALI Addressable (Page 70) Available with Auto-Test/Push-Test function (Page 9) Denotes 1 year warranty 22 Escape Route O Galaxy Circular IP 65 Product Code Operation Lamp Battery Lumen VA Weight GCM3/F162D GCNM3/F162D GCM3/F282D GCNM3/F282D *GCM3/F382D GCNM3/F382D M N-M M N-M M N-M 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 6.0V / 4.0A/h 6.0V / 4.0A/h 114 134 191 224 210 248 2.3kg 2.0kg 2.4kg 2.1kg 2.4kg 2.1kg 16W 2D 16W 2D 28W 2D 28W 2D 38W 2D 38W 2D 33.5 8 39.7 8 40.9 7.6 *Please specify /240v after the above code for mains operation **Please specify /LED after the above code for LED operation 360 mm 83mm Circular Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • Dimensions: 360 x 83 (mm) Flame retardant polycarbonate diffuser and base (IP 65) White finish as standard. Other colours on request Also available with NETCOM 5XP or DALI Addressable (Page 70) Available with Auto-Test/Push-Test function (Page 9) Denotes 1 year warranty 23 Escape Route Nova Square The Nova Square luminaire is a robust, versatile and unobtrusive circular cast aluminium exterior IP65 emergency luminaire bulkhead. 300 SERIES O The Nova Square offers an impressive range of colours and styles suitable for wall and ceiling mounted applications. IP65 VANDAL PROOF Please specify /BL for black Add /EY1 Product Code Operation Lamp Battery Lumen VA Weight NSM3/F162D NSNM3/F162D NSM3/F282D NSNM3/F282D NSM3/F382D NSNM3/F382D M N-M M N-M M N-M 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 114 134 191 224 210 248 3.9kg 3.6kg 4.0kg 3.7kg 4.2kg 3.9kg 16W 2D 16W 2D 28W 2D 28W 2D 38W 2D 38W 2D 33.5 8 39.7 8 43 5.8 *Please specify /240V after the above code for mains operation *Please specify /LED after the above code for LED operation Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • Add /GU Dimensions: 350 x 350 x 158 (mm) Flame retardant polycarbonate diffuser (IP 65) Grey/Black finish as standard with opal diffuser Other colours available on request Also available in PLL/PLC lamp Also available with NETCOM 5XP or DALI Addressable (Page 70) Available with Ventilux Movement Sensor (Page 9) Available with Auto Test/Push Test function (Page 9) 24 Add /EY2 Escape Route 300 SERIES O The Nova Circular can be supplied with optional decorative guards or eyelids to create a versatile range of vandal resistant luminaires which are available in non-maintained and maintained emergency lighting versions for 16 watt, 28 Watt or 38 watt 2D lamps. IP65 Nova Circular VANDAL PROOF /BL for Black Add /EY1 Product Code Operation Lamp Battery Lumen VA Weight NCM3/F162D NCNM3/F162D NCM3/F282D NCNM3/F282D NCM3/F382D NCNM3/F382D M N-M M N-M M N-M 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 114 134 191 224 210 248 3.9kg 3.6kg 4.0kg 3.7kg 4.2kg 3.9kg 16W 2D 16W 2D 28W 2D 28W 2D 38W 2D 38W 2D *Please specify /240v after the above code for mains operation *Please specify /LED after the above code for LED operation Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • Add /GU Dimensions: 360 x 178 (mm) Depth Flame retardant polycarbonate diffuser (IP 65) Grey/Black finish as standard with opal diffuser Other colours available on request Also available with NETCOM 5XP or DALI Addressable (Page 70) Available with Ventilux Movement Sensor (Page 9) Available with Auto-Test/Push-Test function (Page 9) 25 33.5 8 39.7 8 43 5.8 Escape Route The robust and durable design of the (IP65) WP Bulkhead Luminaire makes it ideal for a range of exterior and selected interior locations. Operators of leisure centres, car parks, sports facilities, factories and underground walkways will benefit from its tough, tamper resistant construction and ease of installation. O Weatherproof 300 SERIES IP65 The WP range includes a flame retardant ABS body and includes an Opal diffuser as standard. View From 22M Product Code Operation Lamp Battery Lumen VA Weight Escape Route WPM3/F8 WPNM3/F8 WPS3/F8 WPM3/LED/3W WPNM3/LED/3W M N-M Sustained M N-M T5-8 Watt T5-8 Watt T5-8 Watt LED-3 Watt LED-3 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 78 87 87 270 300 20 8 20 12 4 1.6kg 1.5kg 1.6kg 1.6kg 1.5kg Exit Signage WPM3/F8/EXIT WPNM3/F8/EXIT WPM3/LED/EXIT WPNM3/LED/EXIT M N-M M N-M T5-8 Watt T5-8 Watt LED-1 Watt LED-1 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h N/A N/A N/A N/A 20 8 4 2 1.6kg 1.5kg 1.6kg 1.5kg *Please specify /240v after the above code for mains operation *Please specify /3C after the above code for 3 Cell High Output Battery Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • Dimensions: 368 x 150 x 102 (mm) White finish as standard. Other colours available on request Prismatic or Screen Print diffuser also available Recessing Kit available on request Also available as Cold Room fitting please contact Ventilux Sticker legends (Page 74) Also available with NETCOM 5XP or DALI Addressable (Page 70) Available with Auto-Test/Push-Test function (Page 9) 26 Its robust construction of a cast aluminium base and polycarbonate diffuser make it ideal for use in schools, leisure and community centres and all industrial and public access areas either as an emergency or mains luminaire. Escape Route O A wide range of design and performance features make the Weatherlux Luminaire ideal for exterior and selected interior locations. IP65 Weatherlux VANDAL PROOF View From 22M Product Code Operation Lamp Battery Lumen VA Weight Escape Route WLM3/F8 WLNM3/F8 WLS3/F8 WLM3/LED/1W WLNM3/LED/1W M N-M Sustained M N-M T5-8 Watt T5-8 Watt T5-8 Watt LED-1 Watt LED-1 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h 78 87 87 120 120 20 8 20 5 2.3 2.0kg 1.6kg 2.1kg 2.0kg 1.6kg Exit Signage WLM3/F8/EXIT WLNM3/F8/EXIT WLM3/LED/EXIT WLNM3/LED/EXIT M N-M M N-M T5-8 Watt T5-8 Watt LED-1 Watt LED-1 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h N/A N/A N/A N/A 20 8 4 2 2.0kg 1.6kg 2.0kg 1.6kg *Please specify /240v after the above code for mains operation *Please specify /3C after the above code for 3 Cell High Output Battery Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • Dimensions: 390 x 112 x 92 (mm) Die cast aluminium body (IP65) with Opal diffuser as standard. White finish as standard. Other colours available on request Recessing Kit available on request Sticker legends (Page 74) Also available with NETCOM 5XP (Page 70) Available with Auto-Test/Push-Test function (Page 9) 27 Escape Route O Vision IP65 Available to meet a range of emergency luminaire requirements or as a mains unit, the stylish Vision meets the requirements of all relevant EU Directives and can be supplied in a choice of colours or finishes with all European emergency signage. Ease of installation, as well as a lens design which maximises light distribution are key factors which make the Vision one of the most popular luminaires available from Ventilux. View From 14M Product Code Operation Lamp Battery Lumen VA Weight Escape Route VSM3/F8 VSNM3/F8 VSM3/LED/1W VSNM3/LED/1W M N-M M N-M T5-8 Watt T5-8 Watt LED-1 Watt LED-1 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h 78 87 120 120 20 8 5 2.3 1.5kg 1.2kg 1.5kg 1.2kg Exit Signage VSM3/F8/EXIT VSNM3/F8/EXIT VSM3/LED/EXIT VSNM3/LED/EXIT M N-M M N-M T5-8 Watt T5-8 Watt LED-1 Watt LED-1 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h N/A N/A N/A N/A 20 8 4 2 1.5kg 1.2kg 1.5kg 1.2kg *Please specify /240v after the above code for mains operation *Please specify /3C after the above code for 3 Cell High Output Battery Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • Dimensions: 330 x 95 x 80 (mm) White finish as standard. Other colours available on request Prismatic diffuser as standard. Screen Print/Opal diffuser on request Recessing Kit available on request Sticker legends (Page 74) Also available with NETCOM 5XP (Page 70) Available with Auto-Test/Push-Test function (Page 9) 28 Escape Route For the ultimate in unobtrusive emergency lighting, the flush mounted Trimlite is the epitome of discretion, offering both the specifier and installer a high quality, easy-to-install recessed luminaire. Trimlite 300 SERIES The Trimlite (IP42) is ideal for a wide range of commercial and institutional locations including, for example; offices, hotels, entertainment centres and public buildings. Where appearance is of major importance the Trimlite can also be supplied with brass or chrome finish to reflect the style of prestigious locations. View From 30M Product Code Operation Lamp Battery Lumen VA Weight Escape Route RM3/F8 RNM3/F8 RS3/F8 RM3/LED/3W RNM3/LED/3W M N-M Sustained M N-M T5-8 Watt T5-8 Watt T5-8 Watt LED-3 Watt LED-3 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 4.5A/h 4.8V / 4.5A/h 78 87 87 270 300 20 8 20 12 4 2.2kg 1.9kg 2.2kg 2.0kg 2.0kg Exit Signage RM3/F8/EXIT RNM3/F8/EXIT RM3/LED/EXIT RNM3/LED/EXIT M N-M M N-M T5-8 Watt T5-8 Watt LED-1 Watt LED-1 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h N/A N/A N/A N/A 20 8 4 2 2.2kg 1.9kg 1.6kg 1.6kg *Please specify /240v after the above code for mains operation *Please specify /3C after the above code for 3 Cell High Output Battery Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • Dimensions: 385 x 170 x 7 (mm) White powder-coated galvanised steel trim finish as standard Opal diffuser as standard/Wall or ceiling mounted Please specify /CH (Chrome) /PB (Polished Brass) Other colours on request Screen Print/Prismatic diffuser on request/Sticker legends (Page 74) Also available with NETCOM 5XP (Page 70) Available with Auto-Test (Page 9) 29 Escape Route Specifically designed to please the most discerning of architects and consultants, while retaining the contractor’s needs as a priority, the Verse is a compact and stylish solution to all Emergency Lighting specifiers needs. Verse Purpose-designed for interior use (IP42), the Verse offers a versatility in application second to none. The luminaire includes a flame retardant ABS body and allows the geartray and reflector assembly to be positioned on the base to allow downlight. View From 22M Product Code Operation Lamp Battery Lumen VA Weight Escape Route VRM3/F8 VRNM3/F8 VRM3/LED/1W VRNM3/LED/1W M N-M M N-M T5-8 Watt T5-8 Watt LED-1 Watt LED-1 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h 78 87 120 120 20 8 5 2.3 1.5kg 1.2kg 1.5kg 1.2kg Exit Signage VRM3/F8/EXIT VRNM3/F8/EXIT VRM3/LED/EXIT VRNM3/LED/EXIT M N-M M N-M T5-8 Watt T5-8 Watt LED-1 Watt LED-1 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h N/A N/A N/A N/A 20 8 4 2 1.5kg 1.2kg 1.0kg 1.0kg *Please specify /240v after the above code for mains operation *Please specify /3C after the above code for 3 Cell High Output Battery Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • Dimensions: 360 x 180 x 60 (mm) White finish as standard/Wall or ceiling mounted Clear Polycarbonate diffuser Please specify /CH (Chrome) /PB (Polished Brass) Other colours on request Prismatic diffuser on request/Sticker legends (Page 74) Also available with NETCOM 5XP (Page 70) Available with Auto-Test/Push-Test function (Page 9) 30 Escape Route Subtlety, flexibility and ease of installation are the key features of this recessed fitting. Designed for indoor installation in a wide range of public and commercial locations, the sleek aesthetics of the flush mounted Vantage make it the ideal solution wherever discreet emergency lighting is required. Vantage The standard recessed luminaire can be transformed into an edge lit product, by means of a slotted diffuser and hanging panel option, with all signage complying with European Directives. View From 30M Product Code Operation Lamp Battery Lumen VA Weight Escape Route VAM3/F8 VANM3/F8 VAM3/LED/1W VANM3/LED/1W M N-M M N-M T5-8 Watt T5-8 Watt LED-1 Watt LED-1 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h 78 87 120 120 20 8 5 2.3 1.9kg 1.6kg 1.9kg 1.6kg Exit Signage VAM3/F8/EXIT VANM3/F8/EXIT VAM3/LED/EXIT VANM3/LED/EXIT M N-M M N-M T5-8 Watt T5-8 Watt LED-1 Watt LED-1 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h N/A N/A N/A N/A 20 8 4 2 2.0kg 1.7kg 1.4kg 1.4kg *Please specify /240v after the above code for mains operation *Please specify /3C after the above code for 3 Cell High Output Battery Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • Dimensions: 426 x 161 x 86 (mm) White ABS body with Clear Polycarbonate diffuser as standard (IP20) Recessed Ceiling Mounted Please specify /CH (Chrome) /PB (Polished Brass) Other colours on request Opal diffuser on request Directional panels (Page 74) Also available with NETCOM 5XP (Page 70) Available with Auto-Test/Push-Test function (Page 9) 31 Escape Route A complete range of ultra low profile luminaires suitable for wall and ceiling mounting. Unique styling with moulded caps and coated extruded aluminium side rails has made the range popular with consultants, architects and users alike. Eclipse Mini Both Eclipse Maxi and Mini can be used as bulkheads to illuminate escape routes, or as directional exit signs with European Directive Format self-adhesive legends or custom screen-print solutions. View From 30M Product Code Operation Lamp Battery Lumen VA Escape Route BKM3/F8 BKNM3/F8 M N-M T5-8 Watt T5-8 Watt 2.4V / 4.5A/h 78 2.4V / 4.5A/h 87 20 8 1.9kg 1.6kg Exit Signage BKM3/F8/EXIT BKNM3/F8/EXIT BKM3/LED/EXIT BKNM3/LED/EXIT M N-M M N-M T5-8 Watt T5-8 Watt LED-1 Watt LED-1 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h 20 8 4 2 2.0kg 1.7kg 1.4kg 1.4kg N/A N/A N/A N/A *Please specify /240v after the above code for mains operation *Please specify /3C after the above code for 3 Cell High Output Battery Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • Dimensions: 460 x 180 x 65 (mm) Surface or ceiling mounted White ABS body with Opal Polycarbonate diffuser as standard (IP42) Screen Print diffuser on request/Sticker legends (Page 74) Please specify /CH (Chrome) /PB (Polished Brass) Other colours on request Also available with NETCOM 5XP (Page 70) Available with Auto-Test/Push-Test function (Page 9) 32 Weight Escape Route The Eclipse Maxi and Mini are available as selfcontained or centrally supplied emergency luminaires and are perfectly suited for use in conjunction with either of Ventilux’s two testing systems, Netcom5 or Autotest. Eclipse Maxi 300 SERIES View From 30M Product Code Operation Lamp Battery Lumen VA Escape Route EKM3/F8 EKNM3/F8 M N-M T5-8 Watt T5-8 Watt 2.4V / 4.5A/h 78 2.4V / 4.5A/h 87 20 8 2.2kg 1.9kg Exit Signage EKM3/F8/EXIT EKNM3/F8/EXIT EKM3/LED/EXIT EKNM3/LED/EXIT M N-M M N-M T5-8 Watt T5-8 Watt LED-1 Watt LED-1 Watt 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h 20 8 4 2 2.3kg 2.0kg 1.7kg 1.7kg N/A N/A N/A N/A Weight *Please specify /240v after the above code for mains operation *Please specify /3C after the above code for 3 Cell High Output Battery 515 mm • • • • • • • 235 mm Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration Dimensions: 515 x 235 x 65 (mm) Surface or ceiling mounted White ABS body with Opal Polycarbonate diffuser as standard (IP42) Screen Print diffuser on request/Sticker legends (Page 74) Please specify /CH (Chrome) /PB (Polished Brass) Other colours on request Also available with NETCOM 5XP (Page 70) Available with Auto-Test/Push-Test function (Page 9) 33 34 Stylux Recessed & Halo LED 35 Vista LED 36 Exit Signage 37 Exit Signage The Exlux Sign Luminaire is versatile, unobtrusive and economic. Designed to satisfy statutory requirements for Exit Signs using panels selected from the comprehensive range of types available, which will correctly indicate the direction of the escape route. Exlux Available in white powder coated sheet steel, the housing provides downlight through carefully designed panels in the lower surface to assist in the illumination of the emergency escape route. View From 36M * Please specify /TL for Tiller Lamp Product Code Operation Lamp Battery Lumen VA Weight Escape Route EXM3/F8 EXNM3/F8 EXS3/F8 EXM3/LED EXNM3/LED M N-M Sustained M N-M 4.8V / 1.3A/h 4.8V / 1.3A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h 20 87 87 20 20 2.1kg 1.2kg 2.6kg 2.1kg 2.1kg T5-8 watt T5-8 watt T5-8 watt LED LED * Please specify /DS for Double Sided Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • • Dimensions: 430 x 200 x 60 (mm) White finish as standard (IP42) Available in chrome/CH, Polished Brass/BR and other colours on request Black theatre/cinema version available High temperature Ni-Cd or Ni-Mh battery Side and top 20mm conduit entries and rear BESA box entry Directional panels (page 74) Also available with NETCOM 5XP or Dali addressable Available with Auto-Test/Push-Test function (Page 9) 38 43 5 43 10 4 Exit Signage The Exlux Plus sign luminaire is a versatile, solution to applications requiring a larger than normal viewing distance. O With a 58 metre viewing distance this larger than normal exit sign has numerous applications for indoor and outdoor installation in a range of commercial and industrial locations. Exlux Plus IP65 View From 58M Product Code Operation Lamp Battery Lumen VA Weight Escape Route EX+M3/F18 EX+NM3/F18 EX+M3/LED EX+NM3/LED M N-M M N-M 3.6V / 4.5A/h 3.6V / 4.5A/h 4.8 V /1.3A/h 4.8 V /1.3A/h 151 173 32 32 6.4kg 6.4kg 6.1kg 6.1kg T5-18 Watt T5-18 Watt LED LED * Please specify /DS for Double Sided Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • Dimensions: 730 x 300 x 160 (mm) White finish as standard (IP42) Available in chrome/CH, Polished Brass/BR and other colours on request High temperature Ni-Cd or Ni-Mh battery Side and top 20mm conduit entries and rear BESA box entry Directional panels (page 74) Also available with NETCOM 5XP or Dali addressable Available with Auto-Test/Push-Test function (Page 9) 39 38 12 27 4 Exit Signage The Vasari LED luminaire is a versatile and stylish emergency luminaire. Vasari Offering 10 high intensity white LEDs as the alternative lamp source compared to a conventional 8 watt tube, the Vasari LED offers the client a long term maintenance and operational cost saving, compared to conventional 8 watt luminaires. Available in white-powder coated sheet steel, or with a polished brass finish, the housing provides a versatile ceiling or wall mounted option. View From 36M * Please specify / TL (Tiller Lamp) Product Code Operation Lamp Battery Lumen VA Weight VAIM3/F8 VAINM3/F8 VAIM3/LED VAINM3/LED M N-M M N-M T5-8 Watt T5-8 Watt LED LED 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h 78 87 10 10 20 8 10 4 2.8kg 2.5kg 2.3kg 2.3kg Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • • Dimensions: 442.5 x 363 x 92 (mm) Polycarbonate diffuser as standard High temperature Ni-Cd or Ni-Mh battery Two 20mm conduit entries at the rear of body White finish as standard (IP42) Available in chrome/CH, Polished Brass/BR and other colours on request Directional panels (page 77) Also available with NETCOM 5XP or DALI addressable Available with Auto-Test / Push-Test function (Page 9) 40 Exit Signage Engineered with ease of installation and cost effectiveness as a focus, the Glade achieves its’ goals while offering an exciting aesthetic to rival any edgelit sign luminaire on the market. Glade The Glade geartray is fixed to the wall or ceiling as a first fix, and the rest of the assembly simply clips together. The unique panel assembly ensures the perfect blend of clean, aesthetic and highly illuminated signage. View From 36M Product Code Operation Lamp Battery Lumen VA Weight GDM3/F8 GDNM3/F8 GDM3/LED GDNM3/LED M N-M M N-M 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3 A/h 4.8V / 1.3A/h 78 87 10 10 3.1kg 2.8kg 2.6kg 2.6kg T5 - 8 watt T5 - 8 watt LED LED Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • Dimensions: 460 x 505 x 102 (mm) Chrome finish as standard (IP42) Available in Polished Brass/BR and other colours on request Directional panels (page 74) Also available with NETCOM 5XP or DALI addressable Available with Auto-Test / Push-Test function 41 20 8 10 4 Exit Signage Designed to satisfy the statutory requirements for indoor exit signs the Stylux luminaire is ideal for those installations where there is an emphasis on clear and aesthetic signage. Stylux Allowing versatility for each application, the Stylux can be wall or ceiling mounted. In addition it can be fitted with a cantilever wall bracket to allow further installation flexibility to the client. *Please specify /TL (Tiller Lamp) View From 28M Product Code Operation Lamp Battery Lumen VA Weight STM3/F8 STNM3/F8 STM3/LED STNM3/LED M N-M M N-M 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h 78 87 10 10 2.0kg 1.9kg 2.0kg 1.9kg T5-8 Watt T5-8 Watt LED LED 20 8 5 3 Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • Dimensions: 345 x 285 x 60 (mm) Polycarbonate diffuser as standard (IP42) High temperature Ni-Cd or Ni-Mh battery White / WH, chrome/CH, Polished Brass/BR finish as standard Other colours available on request Directional panels (page 74) Also available with NETCOM 5XP Available with Auto-Test/Push-Test function (Page 9) 42 */PB for Polished Brass Exit Signage As an alternative to the standard Stylux blade exit sign luminaires, the Ventilux Stylux Recessed provides the same combination of style and design in a high quality luminaire in which all of the control equipment is fully recessed into the ceiling. Stylux Recessed All versions of the Stylux luminaires are designed and manufactured to meet current and future product standards and the appropriate requirements of all EU directives. View From 36M *Please specify /TL (Tiller Lamp) Product Code Operation Lamp Battery Lumen VA Weight RSTM3/F8 RSTNM3/F8 RSTM3/LED RSTNM3/LED M N-M M N-M 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h 78 87 10 10 2.8kg 2.5kg 2.3kg 2.3kg T5-8 Watt T5-8 Watt LED LED Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • • Dimensions: 508 x 112 x 288 (mm) Polycarbonate diffuser as standard High temperature Ni-Cd or Ni-Mh battery Two 20mm conduit entries at side and rear surface of recessed body White, chrome or Polished Brass finish as standard (IP42) Other colours available on request Directional panels (page 74) Also available with NETCOM 5XP or DALI addressable Available with Auto Test / Push Test function (Page 9) 43 20 8 10 4 Exit Signage Another industry first from Ventilux. A unique combination of engineering and design makes Focal an ideal choice for all installations where emergency lighting is to be an integral part of the overall design. The main body is manufactured from an aluminium casting that houses the concave reflector and legend panels. Focal Specifically designed to compliment the latest trends in interior design and architectural practice, Focal is a sleek departure from the norm in Emergency Lighting signage. Focal is ideal for those installations where there is an emphasis on clear signage and aesthetic appearance. View From 36M Product Code Operation Lamp Battery Lumen VA Weight FLM3/F8 FLNM3/F8 FLM3/LED FLNM3/LED M N-M M N-M 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h 78 87 8 8 3.2kg 2.9kg 2.7kg 2.7kg T5-8 Watt T5-8 Watt LED LED Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • Dimensions: 648 x 225 x 60 (mm) High temperature Ni-Cd or Ni-Mh battery. Two 20mm conduit entries at rear Stainless steel finish as standard (IP42) Available in chrome/CH and other colours on request Directional panels (page 74) Also available with NETCOM 5XP or DALI addressable Available with Auto-Test/Push-Test function (Page 9) 44 20 8 10 4 Exit Signage Designed in conjunction with the Eclipse Maxi and Mini, this double sided sign follows their ultra slim styling, making the Eclipse range a leading concept in emergency lighting design. Eclipse Dual The Eclipse Dual’s design ensures an ease of installation coupled with sleek lines, which combine to make it the natural choice of both specifying consultants and contractors alike. Available as a self-contained or centrally supplied emergency luminaire, the Eclipse is built and tested to current European standards and is designed to comply with all relevant EU directives. View From 22M Product Code Operation Lamp Battery Lumen VA Weight DKM3/F8 DKNM3/F8 DKM3/LED DKNM3/LED M N-M M N-M 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V / 1.3A/h 4.8V / 1.3A/h 78 20 20 20 1.8kg 1.3kg 1.3kg 1.3kg T5-8 Watt T5-8 Watt LED LED Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • • Dimensions: 440 x 260 x 65 (mm) Flame Retardant ABS body High temperature Ni-Cd or Ni-Mh battery. BESA box mounting as standard White finish as standard (IP42) Available in chrome/CH, Polished Brass/BR and other colours on request Directional panels (page 74) Also available with NETCOM 5XP or Dali addressable Available with Auto-Test/Push-Test function (Page 9) 45 20 8 10 4 Exit Signage The development of the Vanguard range marks yet another unique progression in emergency lighting. Vanguard Designed to seamlessly integrate into the interior aesthetics of prestigious modern developments, and produced from the highest quality materials, the Vanguard range will appeal to architects, consultants and contractors who require a flexible and innovative approach to emergency lighting. / WM for wall mounted /CM for ceiling mounted View From 34M Product Code Operation Lamp Battery VGM3/LED VGNM3/LED M N-M 4.8V / 1.3A/h 8 4.8V / 1.3A/h 8 LED LED Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • Dimensions: Surface Mounted Version- 298 x 100 x 75 (mm) Stainless Steel housing with 4mm or 10mm Screen Print Legend (IP20) Other colours on request Multiple mounting option (Other dimensions on request) High temperature Ni-Mh battery Directional panels (page 74) Also available with NETCOM 5XP (Page 70) Available with Auto-Test/Push-Test function (Page 9) 46 Lumen VA 4 2 Weight 2.9kg 2.9kg Exit Signage The family of products is specifically designed to enable a cohesive directional emergency lighting solution, adaptable to all mounting scenarios within a specified project. B A Vanguard Wall mounted option /VGD/WK Wall mounted bracket option VGD/WBK A B 47 Exit Signage Designed to seamlessly integrate into the interior aesthetic of prestigious modern developments and produced from the highest quality materials, the Vista Range will appeal to architects and consultants who require flexible and innovative approach to emergency lighting. Vista Single-Sided View From 34M Product Code Operation Lamp Battery Lumen VA Weight VTM3/LED VTNM3/LED VTM3/F8 VTNM3/F8 M N-M M N-M 4.8V / 1.3A/h 4.8V / 1.3A/h 2.4V / 4.5A/h 2.4V / 4.5A/h 8 8 78 87 2.6kg 2.6kg 3.2kg 2.9kg LED LED T5-8 watt T5-8 watt Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • Dimensions: Surface Mounted Version- 464x200x96 (mm) Stainless Steel housing with opal polycarbonate legend (IP20) Other colours on request Multiple mounting option High temperature Ni-Cd or Ni-Mh battery Directional panels (page 74) Also available with NETCOM 5XP or DALI (Page 70) Available with Auto-Test/Push-Test function (Page 9) 48 8 4 20 8 Exit Signage This family of products is specifically designed to enable a cohesive directional emergency lighting solution, adaptable to all mounting scenarios within a specific project. Vista Double-Sided View From 34M Product Code Operation Lamp Battery Lumen VA Weight VTM3/LED/2 VTNM3/LED/2 VTM3/F8/2 VTNM3/F8/2 M N-M M N-M 4.8V / 1.3A/h 4.8V / 1.3A/h 2.4V / 4.5A/h 2.4V / 4.5A/h 8 8 78 87 2.6kg 2.6kg 3.2kg 2.9kg LED LED T5-8 Watt T5-8 Watt Mounting kits available • Order VT/BCK for bracket ceiling kit • Order VT/BWK for bracket wall kit • Order VT/FCK for flush ceiling kit • Order VT/FWK for flush wall kit Please note these mounting kits are not supplied as standard and need to be ordered separately with standard product. Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • Dimensions: Surface Mounted Version- 464x200x96 (mm) Stainless Steel housing with opal polycarbonate legend (IP20) Other colours on request Multiple mounting option High temperature Ni-Cd or Ni-Mh battery Directional panels (Page 74) Also available with NETCOM 5XP (Page 70) Available with Auto-Test/Push-Test function (Page 9) 49 8 4 20 8 Exit Signage O Visage Designed for indoor and outdoor installation in a range of commercial and industrial locations, the compact Visage Luminaire offers a high level of specification, ease of installation and excellent value for money. IP65 View From 22M Product Code Operation Lamp Battery Lumen VA Weight VGM3/F8 VGNM3/F8 VGM3/LED VGNM3/LED M N-M M N-M 2.4V / 4.5A/h 2.4V / 4.5A/h 4.8V /1.3A/h 4.8V / 1.3A/h 78 87 8 8 2.2kg 1.9kg 1.7kg 1.7kg T5-8 Watt T5-8 Watt LED LED Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • ª • • • • • Dimensions: 368 x 304 x 150 (mm) Opal polycarbonate diffuser Flame retardant ABS body High temperature Ni-Cd or Ni-Mh battery Side and end 20mm conduit entries and rear BESA box mounting as standard White finish as standard Other colours available on request Sticker legends (page 74) Also available with NETCOM 5XP or DALI (Page 70) Available with Auto-Test/Push-Test function (Page 9) 50 20 8 10 4 Exit Signage Exlux IP67 O The robust and durable design of the Exlux IP67 Luminaire makes it ideal for a range of exterior and selected interior locations. Operators of leisure centre, car parks, sports facilities, factories and underground walkways will benefit from its tough, resistant construction and ease of installation. IP67 View From 30M Product Code Operation Lamp Battery Lumen VA Weight EXM3/F8/IP65 EXNM3/F8/IP65 EXM3/LED/IP65 EXNM3/LED/IP65 M N-M M N-M 3.6V/4.5A/h 3.6V/4.5A/h 4.8V/1.3A/h 4.8V/1.3A/h 78 87 20 20 3.4kg 3.1kg 2.9kg 2.9kg T5-8 Watt T5-8 Watt LED LED Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • Dimensions: 379 x 189 x 130 (mm) Flame retardant ABS housing with polycarbonate diffuser Other colours on request High temperature Ni-Cd or Ni-Mh battery Directional panels (Page 74) Also available with NETCOM 5XP or DALI (Page 70) Available with Auto-Test/Push-Test function (Page 9) 51 20 8 4 2 52 Focal LED... Twinspots & Tungsten Halogen Lighting 53 Twinspots & Tugsten Halogen Lighting Purpose designed for interior use, the Scout luminaire houses a unique swivel and rotate system, which allows independent positioning of the projectors, giving the installer more flexibility on installation. Scout Unlike other twin projector luminaires, the Scout not only includes a unique rotate reflector system, but also an aesthetically pleasing compact enclosure which will blend into almost any decor, where open area lighting must be provided to direct persons escaping along the defined escape route. /PB for Polished Brass Product Code Operation Lamp SC10/NM3 SC20/NM3 SC6LED/NM3 N-M N-M N-M TH-2 x 10 Watt 12V / 7.0A/h TH-2 x 20 Watt 12V / 14.0A/h LED-2 x 3Watt 4.8V / 4.5A/h Black Finish Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • */WH for white Dimensions: 384 x 214 x 132 (mm) Stainless Steel housing (IP20) Maintenance free sealed lead acid battery Available in /WH (White) /BR (Polished Brass) Other colours on request Surface or Semi-Recessed housing Also available with Remote Lamps complete with Bracket Also available with NETCOM 5XP (Page 70) Available with Auto-Test/Push-Test function (Page 9) 54 Battery Lumen VA Weight 280 600 360 5.4kg 7.8kg 7.8kg 40 40 8.9 Twinspots & Tugsten Halogen Lighting Purpose designed for interior use, the Corona luminaire is designed to fit into a hole size of 135mm, and comes in two parts, giving the installer more flexibility and ease on installation. Corona Semi-recessed, to yield a depth of only 13mm, the Corona is the discreet option of stylish Emergency Lighting installations. Product Code Operation Lamp Battery Lumen Weight CANM3/5TH CANM3/10TH CANM3/20TH N-M N-M N-M TH-5 Watt TH-10 Watt TH-20 Watt 12V/7.0A/h 12V/7.0A/h 12V/7.0A/h 60 140 300 Brass Finish Silver Finish Black Finish Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • Dimensions: 168 * 36.50 (mm) Discrete pressed-steel hosuing with aluminium spun reflector (IP20) Available in /WH (White) /BR (Polished Brass) /CH (Chrome) Other colours on request Maintenance free sealed lead acid battery Also available with NETCOM 5XP (Page 70) Available with Auto-Test/Push-Test function (Page 9) 55 4.6kg 4.6kg 4.6kg Twinspots & Tugsten Halogen Lighting For industrial areas, factories or warehouses with aisles and specific hazards causing obstruction, open area lighting must be provided to direct persons escaping onto the defined escape route. Twinlux The provision of Emergency Lighting in these areas is best achieved through the use of Ventilux Twinlux Twin Projector Luminaires. Designed to project the light output from the high efficiency halogen lamps exactly where needed, these luminaires can be provided in versions suitable for normal interior applications or with either IP55 or IP67 degree of protection from dust and water ingress. TL20 Product Product Code Operation Lamp TL20/NM3 TL55/NM3 N-M N-M IP67 WTL20/NM3 WTL55/NM3 N-M N-M Lumen VA Weight TH-2 x 20 Watt 12V/14.0A/h TH-2 x 55 Watt 12V/42.0A/h 600 1900 24 24 9.4kg 22kg TH-2 x 20 Watt 12V/14.0A/h TH-2 x 55 Watt 12V/42.0A/h 600 1900 24 24 9.0kg 21kg *please note WLT20/NM3 supplied with lamps underneath housing as standard. WTL55/TL20/TL55 supplied with lamps on top of housing. Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • • • • Dimensions: 360 x 180 x 60 (mm) White/Grey powder coated galvanised sheet steel Other colours on request Maintenance free sealed lead acid battery Deep battery discharge protection circuitry Polycarbonate lenses upon request for food preperation areas Wide rotational lamp head (360°) Also available with Remote Lamps complete with bracket Delay timer optional Also available with NETCOM 5XP (Page 70) Available with Auto-Test/Push-Test function (Page 9) 56 Battery Twinspots & Tugsten Halogen Lighting Twinlux 57 Twinspots & Tugsten Halogen Lighting CTL - Compact Twin Lamp The Compact Twinspot (CTL) range of luminaires have been specifically designed to provide emergency lighting in high bay industrial areas, factories or large warehouses where there is a requirement to project high intensity beams between the racks and equipment to illuminate walkways and assist safe evacuation in case of emergency. Product Code Operation Lamp Battery CTL20/NM3 N-M TH-2 x 20 Watt 12V/ 14.0A/h Lumen VA Weight 600 9.4kg 24 LED indication of correct charger function and lamp filaments continuity. Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 110 / 230 Volts AC/DC System Voltage For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration • • • • • • • • • • • Dimensions: 330 x 210 x 69 (mm) White/Grey powder coated galvanised sheet steel (IP20) Other colours on request Maintenance free sealed lead acid battery Deep battery discharge protection circuitry Polycarbonate lenses upon request for food preperation areas Wide rotational lamp head Also available with Remote Lamps complete with bracket Delay timer optional Also available with NETCOM 5XP (Page 70) Available with Auto-Test/Push-Test function (Page 9) */BL for Black 58 Emergency Conversion Power Packs 59 Emergency Conversion Power Packs Independent LED Conversion Module The exceptionally low profile 'Indepentent' KPLED conversion kit can be fitted inside the latest generation slimline luminaires and offers a cost effective solution to conventional linear fluorescent lamp conversions. Purpose designed to provide emergency lighting conversion of all mains lighting luminaires, the convertalux KPLED series has been designed specifically to operate fully independent of the existing high frequency ballast, allowing a much easier and lower-risk conversion. Product Code Description Range of LED Lamps KPNMC-4-1 KPNMC-4-3 KPNMC-4-3 1 watt LED inverter module 1 watt @ 350mA 3 watt LED inverter module 3 watt @ 650mA 3x1 watt LED inverter module 3 x 1 watt @ 350mA * Add RP instead of KP for remote hosuing assembly for example RPNMC-4-1 * Please add /DL for Downlighter Conversions • • • • • • • • Assembly complete with charge indicating LED, Battery Pack and Clips. Suitable for integral and remote mounting options. Lamp head suitable for mounting on plastic surfaces due to integral heat sink. LEDs manufactured by CREE. 1 watt option provides 100 lumens in emergency operation. 3 watt option provides 180 lumens in emergency operation. 3x1 watt option provides 300 lumens in emergency operation. Module dimensions 148 x 25 x 27 mm. 60 Lumens 100 180 300 The Mains LED conversion kit can be fitted inside the latest LED linear and LED down lighter luminaires. This module offers a cost effective solution to linear and down lighter fluorescent lamp conversions. The low profile module incorporates a constant current battery charger suitable to recharge and maintain the charge of the connected nickel cadmium battery. Emergency Conversion Power Packs Mains LED Conversion Module The key benefit of this unit is just the output is configurable to seven separate output voltage/current configurations, to cover a wide range of LED types and mains wattages. Product Code Description Range of LED Lamps KPM-4-5W/12V KPM-4-5W/18V KPM-4-5W/27V KPM-4-5W/36V KPM-5-5W/40V KPM-5-5W/50V KPM-5-5W/65V 5 Watt LED Inverter Module 5 Watt LED Inverter Module 5 Watt LED Inverter Module 5 Watt LED Inverter Module 5 Watt LED Inverter Module 5 Watt LED Inverter Module 5 Watt LED Inverter Module 390 mA @ 12v 260 mA @ 18v 175 mA @ 27v 130 mA @ 36v 125 mA @ 40v 100 mA @ 50v 77 mA @ 65v * please note to establish whether a mains LED luminaire can be converted is based on secondary output voltage and not wattage. • • • • • • • • • Low profile slimline module suitable for the conversion of LED mains applications. Compatible with all high frequency mains ballasts via on-board switched live contacts. High efficiency LED driver for excellent emergency lumen output. LED conversion pack electrically isolated from mains control gear. Module dimensions 170 x 35 x 38 mm. Enclosure fixing centre 160 mm. Assembly complete with charge indicating LED, Battery Pack and Clips. Suitable for integral and remote mounting options. Suitable for use with Ni-Mh or Ni-Cd batteries. 61 Emergency Conversion Power Packs The Convertalux KPHFM Seriess is a low profile conversion kit for mains luminaires with 7 to 85 watt fluorescent lamps with or without remote mounting. Suitable for both switch start and high frequency control gear. Assembly complete with charge indicating LED, Battery Pack and Clips. Convertalux KPHFM Series Product Code Description Range of Lamps BLF KPHFM-3-18 18 watt T8 inverter module, complete with battery and charge LED 18 watt PLL 7 watt PLS 9 watt PLS 10 watt PLC 4 watt T5 6 watt T5 8 watt T5 18 watt T8 0.15 0.29 0.21 0.38 0.39 0.33 0.31 0.16 KPHFM-4-58 58 watt T8 inverter module, complete with battery and charge LED 11 watt PLS 18 watt PLL 36 watt PLL 13 watt PLC 18 watt PLC 26 watt PLC 18 watt TCT 40 watt T12 65 watt T12 36 watt T8 58 watt T8 0.17 0.14 0.12 0.26 0.19 0.19 0.17 0.09 0.07 0.09 0.08 KPHFM-4-28 28 watt 2D inverter module, complete with battery and charge LED 16 watt 2D 28 watt 2D 0.21 0.14 KPHFM-5-38 38 watt 2D inverter module, complete with battery and charge LED 38 watt 2D 0.12 KPHFM-5-70 70 watt T8 inverter module, complete with battery and charge LED 70 watt T8 85 watt T12 0.07 0.09 • Remote Pack Dimensions: 145 x 55 x 395 (mm) • All conversion module supplied with high temperature Ni-Cd batteries • Ni-Mh batteries available on request • 20mm conduit entries in end and rear surfaces of remote mounting box • IP65 remote pack available on request 62 Emergency Conversion Power Packs The Convertalux KPT5 Series is an emergency conversion module designed to fit into the latest generation T5, TCT and PLL slimline luminaires. Suitable for both switch start and high frequency control gear. Assembly complete with charge indicating LED Battery Pack and Clips. Convertalux KPT5 Series Product Code Description Range of Lamps BLF KPHFM-4-14/HE KPHFM-6-21/HE KPHFM-6-24/HO KPHFM-6-28/HE KPHFM-6-35/HE KPHFM-6-39/HE KPHFM-6-49/HE KPHFM-6-54/HE KPHFM-6-80/HE KPHFM-6-18/TCT KPHFM-6-24/TCT KPHFM-6-26/TCT KPHFM-6-32/TCT KPFM-6-42/TCT KPHFM-6-40/PLL KPHFM-6-55/PLL KPHFM-6-40/CIR 14 watt T5 inverter module 21 watt T5 inverter module 24 watt T5 inverter module 28 watt T5 inverter module 35 watt T5 inverter module 39 watt T5 inverter module 49 watt T5 inverter module 54 watt T5 inverter module 80 watt T5 inverter module 18 watt TCT invertermodule 24 watt TCT inverter module 26 watt TCT inverter module 32 watt TCT inverter module 42 watt TCT inverter module 40 watt PLL inverter module 55 watt PLL inverter module 40 watt CIR inverter module 14 watt T5 HE 21 watt T5 HE 24 watt T5 HO 28 watt T5 HE 35 watt T5 HE 39 watt T5 HO 49 watt T5 HO 54 watt T5 HO 80 watt T5 HO 18 watt TCT 24 watt TCT 26 watt TCT 32 watt TCT 42 watt TCT 40 watt PLL 55 watt PLl 40 watt Circular 0.23 0.19 0.12 0.13 0.12 0.12 0.09 0.08 0.06 0.18 0.14 0.14 0.13 0.07 0.10 0.06 0.10 * Please specify RP instead of KP in above code for remote housing assembly. • • • • • • Assembly complete with charge indicating LED, Battery Pack and Clips. Remote Pack Dimensions: 145 x 55 x 395 (mm) All conversion modules supplied with high temperature Ni-Cd batteries Ni-Mh batteries available on request 20mm conduit entries in end and rear surfaces of remote mounting box IP65 remote pack available on request 63 Emergency Conversion Power Packs The Ventilux LED 5 watt and 10 watt MR16 conversion kits are designed to convert the latest 10 watt low voltage MR16 LED down lighters to emergency lighting operation. LED MR16 Conversion Pack Housed in a flexible silicone coated fiberglass enclosure the product is designed to pass through a 65mm diameter hole in the ceiling. The silicone coated enclosure provides excellent electrical isolation, high temperature resistance and corrosion resistance. Product Code Operation Lamp Cut-out Ceiling Void Battery Weight VLEDSP5/NM3 VLEDSP5/M3 VLEDSP10/NM3 VLEDSP10/M3 N-M M N-M M LED / 5 W LED / 5 W LED / 10 W LED / 10 W 65mm 65mm 65mm 65mm 110mm 110mm 110mm 110mm 4.8V / 4.5A/h 4.8V / 4.5A/h 12V / 4.5A/h 12V / 4.5A/h 1.1kg 1.1kg 1.45kg 1.45kg 60 mm 800 mm • • • • • • • Can be used for Non-Maintained or Maintained operation. Lamp supplied as standard by Ventilux. Assembly complete with charge indicating LED. 5 watt comparable to 12 V / 20W Tungsten Halogen. 10 watt comparable to 12 V / 50W Tungsten Halogen. Suitable for through hole mounting and connection via a 65mm cut-out. Suitable for a ceiling void of 110mm. 64 Emergency Conversion Power Packs Convertalux Starpack is an emergency lighting conversion kit for the conversion of 12V 20W and 50W tungsten halogen luminaires. Assemblies utilise plug-in battery and lamp connectors. Convertalux Starpack THSP50/NM3 Product Code Operation Lamp Cut-out Ceiling Void BLF Battery Weight THSP20/NM3 THSP20/M3 THSP50/NM3 THSP50/M3 THSP20/NM3/NIMH THSP20/M3/NIMH THSP50/NM3/NIMH THSP50/M3/NIMH N-M M N-M M N-M M N-M M 12V / 20W TH 12V / 20W TH 12V / 50W TH 12V / 50W TH 12V / 20W TH 12V / 20W TH 12V / 50W TH 12V / 50W TH 80mm 80mm 80mm 80mm 65mm 65mm 65mm 65mm 110mm 110mm 110mm 110mm 220mm 220mm 220mm 220mm 8% 8% 8% 8% 10% 10% 10% 10% 6V / 5.0A/h 6V / 5.0A/h 6V / 14.0A/h 6V / 14.0A/h 6V / 7.0A/h 6V / 7.0A/h 6V / 13.0A/h 6V / 13.0A/h 1.85kg 1.85kg 4.6kg 4.6kg 1.75kg 1.75kg 1.95kg 1.95kg * For a maintained product specify when ordering whether a maintained transformer is required THSP50/NM3/NIMH • • • • • Suitable for throughhole mounting of either 65mm or 80mm Available in two options, suitable for ceiling voids of 110mm or 220mm. 100% rated lumen output from emergency lamps upon request. Available with either maintenance-free sealed lead acid or Ni-Mh batteries Ni-Mh batteries assemblies housed in a silicone coated fire retardant bag for ease of installation. 65 Emergency Conversion Power Packs The Convertalux TH Pack is a compact power pack for the conversion of low voltage Tungsten Halogen lighting to emergency lighting operation. There is an optional 100% rated lumen output from Tungsten Halogen lamps in emergency operation. Convertalux TH Pack Product Code Operation H W D Lamp Type BLF Battery Weight TH20/NM3 TH20/M3 TH50/NM3 TH50/M3 TH50/NM3/C TH50/M3/C N-M M N-M M N-M M 227 227 280 280 227 227 325 325 465 465 325 325 85 85 68 68 85 85 12V / 20W TH 12V / 20W TH 12V / 50W TH 12V / 50W TH 12V / 50W TH 12V / 50W TH 100% 100% 100% 100% 10% 10% 12V / 14.0A/h 12V / 14.0A/h 12V / 21.0A/h 12V / 21.0A/h 6V / 12.0A/h 6V / 12.0A/h 5.1kg 6.0kg 10.2kg 12.5kg 5.1kg 6.0kg and Maximum cable length in metres form TH pack to luminaire 1.5mm2 2.5mm2 4.0mm2 TH20/NM3 TH20/M3 TH50/NM3 TH50/M3 TH50/NM3/RO TH50/M3/RO 14 25 36 14 25 36 6 10 16 6 10 16 14 25 36 14 25 36 * Please note if cable distance exceeds 1 metre PH120 cable has to be used as the product is deemed a central battery fitting (remote pack to lamp head) • • • • • • Maintenance-free sealed lead acid batteries Ni-Cd or Ni-Mh batteries available upon request Compact white powder-coated galvanised steel enclosure providing an IP rating of IP22 Polycarbonate IP65 enclosure available upon request. 75 watt and 100 watt versions available upon request. Side and end 20mm conduit entries 66 By functioning as both a mains LED driver and emergency LED driver, the QPCM4-LED conversion kit provides an environmentally friendly, long life and economically viable alternative to a traditional fluorescent conversion pack. Offering light output comparable to a conventional 28 watt 2D fluorescent lamp, the QPCM4-LED offers the client an easy opportunity to significantly reduce their carbon footprints for a relatively low initial investment and very quick payback time. Emergency Conversion Power Packs Convertalux Quick Pack LED Series Product Code Description Range of Lamps Lamp Life QPCM4/LED QP/LED/MAINS QPCEM4/28 QP/4/28/MAINS Emergency Conversion pack Mains Conversion pack Emergency Conversion pack Mains Conversion pack LED LED 28 Watt 2D 28 Watt 2D 50,000 50,000 5,000 5,000 • • • • • • Conversion pack housing made from powder-coated galvanised, sheet steel Incorporating the latest high flux CREE LED's 50,000 hours lamp life Emergency illuminance of 300 lumens. Mains illuminance of 900 lumens. Slimline conversion pack 170 mm L x 165 mm W x 50 mm H. The Convertalux CEM Series features an exceptionally low profile conversion module designed to fit into the latest generation of slimline luminaires. It has a combined electronic maintained version kit for 2D 28 watt (4 pin) compact fluorescent lamps, providing an excellent solution to limited space emergency light applications. Convertalux CEM Series Product Code Description Range of Lamps BLF KPCEM-4-28 CEM-4-28 Inverter module, battery and charge LED Inverter module and charge LED 28 watt 2D 28 watt 2D 0.12 0.12 • • • • • Module size 122 x 78 x 31 mm Ni-Mh batteries available upon request Inverter module enclosed in white, fire retardant polycarbonate housing. Separate switched live and permanent live supplies. Supplied with charge indicating LED, Battery Pack and Clips. 67 Wire Guards Ventilux offer a comprehensive range of wire guards for all their emergency lighting products. Wire guards provide an excellent way to protect emergency luminaires against vandalism and accidental damage. They offer a cost effective way of protecting the capital investment of an emergency lighting system. They are ideal for use in gymnasiums, sport halls, outdoor installations, loading areas, warehouses, schools and apartment complexes. Suitable for both ceiling and wall mounted applications the wire guards are constructed from 5 mm2 galvanised steel wire with a 25 mm square opening, and offer a high level of corrosive resistance for the most harsh environments. Wire guards can also be custom made to individual requirements and to any specific RAL colour - please contact the Ventilux Sales department for further details. 68 Emergency Lighting Systems 69 Emergency Lighting Systems Netcom5 XP WHAT IS NETCOM5 XP? Netcom5 XP is a new approach to automatic testing of emergency lighting installations. Compatible with both self-contained and central battery systems, it has become one of the market leaders in the field of automated testing of emergency lighting installations. The testing system functions on an ethernet backbone and can be easily integrated into an existing Local Area Network (LAN). HOW DOES NETCOM5 XP WORK? Each intelligent luminaire has at its core a stand-alone intelligent testing module (referred to as the “node”), which tests the functionality of the luminaire before reporting back to a central control panel via a localised control module. The node communicates with the control module via a proprietary CAN (Controller Area Network) protocol and the control module communicates to the control panel via industry standard ETHERNET. WHAT IS A NODE? The node is a stand-alone module which can be integrated into any emergency luminaire. Each intelligent luminaire has a network LED (yellow) to indicate network status and a charging LED (green) to indicate mains present and that the battery is charging correctly. The testing system functions independently and is electrically isolated from the emergency lighting installation, so there is no need for the control panel to be on-line continuously or supported by a UPS. HOW MANY NODES CAN I HAVE ON A SYSTEM? The modular structure of the N5XP system allows the system to be scaled to suit any installation from 100 up to 25,300 luminaires. The modular structure also allows for simplistic later expansion of the system. The use of the ETHERNET backbone allows fittings to be over 2000 metres away from the control panel using fibre optic cabling and also allows for remote monitoring. CAN I GROUP MY TESTING? The system allows for 30 independent test groups to be allocated irrespective of the physical location or the electrical circuit allocation, offering flexibility to the end user. 70 Emergency Lighting Systems Netcom5 XP WHAT ELSE CAN NETCOM5 XP DO? With the latest interactive graphics program, the user can interface with an AUTO-CAD floor plan to establish the health of their emergency lighting installation. Site configurations are easily uploaded and downloaded, allowing ease of site set up/commissioning and troubleshooting. WHEN WILL IT TEST THE LUMINAIRES? The default N5XP system tests the emergency installation daily, monthly, 6 monthly and annually in accordance with current legislation. A custom test regime is also available for user settings. With the options for EMAIL and SMS texting reporting, single or multi users, AUTO-CAD graphics package - the N5XP testing systems offers a cutting edge product with the added benefit of peace of mind to the client. KEY FEATURES: • • • • • • • • • • • • • • System can monitor up to 25,300 luminaires. Designed to function with both self contained and central battery luminaires Integrates into an ethernet LAN Compliant to EN62034 Up to 253 channels available Each channel able to run 1000 metres User friendly software 71 AUTO-CAD floor plan integration EMAIL reporting SMS reporting Multi-user access over the LAN Dial in functionality BMS interfacing (specific to BMS protocol) 3 year warranty as standard Emergency Lighting Systems AC STATIC INVERTERS The Ventilux Emergency Lighting (VEL) series of Static Inverters are designed and manufactured in accordance with the latest European standard EN50171. Designed to provide a Static Inverter with all the flexibility and adaptability you need, these modern, compact Static Inverters have the enviable reputation for consistent reliability, ease of installation and maintenance, making it ideal for all emergency lighting installations. In today’s environment, Static Inverter systems must satisfy the most challenging applications, and the versatile VEL series of Static Inverters has all the answers with a wide choice of power ratings. For more information about our Static Inverter Systems please contact us. ELT Central Test Unit The ELT offers cost-competitive central testing, facilitating the interruption and automatic restoration of multiple circuits • On/Off key switch to prevent unauthorised use. • ‘Power On’ indication. • Accurate crystal controlled timer. • Test durations of 40 mins and 3 hours as standard. • Alternative test durations available upon request. • Digital display of elapsed time. • ‘Test in Progress’ indication. • ‘Test Completed’ indication. • Audible warning via buzzer on commencement of final 10 minutes of test. • Automatic restoration of supply on completion of test. • 6, 12 and 18 way circuit Interface Units (IFU) available. • Suitable for self-contained and central battery installations. • Powder-coated galvanised steel enclosure as standard. 72 Designers’ Information 73 74 Designers’ Information Placement of Luminaires PLACEMENT OF LUMINAIRES IS3217 and BS5266 provide detailed guidance on where luminaires shall be installed and what minimum levels of illuminance shall be achieved on the escape routes and in open plan areas. It also specifies what the minimum period of emergency duration shall be after failure of the normal mains lighting. DETERMINE THE POSITIONING OF EMERGENCY LIGHTING LUMINAIRES The first priority is to determine luminaires to illuminate the “Points of Emphasis” AREAS OF PARTICULAR RISK Although they cannot form part of the defined escape route, the following areas are also deemed necessary to have emergency lighting because of the particular risk they present. FIRE SAFETY SIGNS Fire Safety Signs should comply with the requirements of the Signs Directive, unless being used to extend an existing installation when they may be the same format as those previously installed if complying to BS5499 Pt1(UK). The viewing distance of any exit sign should be 200 times the height of the panel if internally illuminated or 100 times the height of the panel is externally illuminated. The sign should also be positioned between 2.5 to 3.0 metres from the floor to optimise viewing. 75 Designers’ Information Levels of Illuminance DETERMINING LEVELS OF ILLUMINANCE a) Emergency Escape Routes. For escape routes up to 2m in width, the horizontal illuminance on the floor along the centre line of an escape route shall not be less than 1 lux and the central band consisting of not less than half the width of the route shall be illuminated to a minimum of 50% of that value. b) Open (Anti-Panic) Areas, For open areas having a floor area greater 60m2 (known as Open Plan or Anti-Panic areas) where no fixed escape route is defined, the requirement is for a minimum of 0.5 lux anywhere on the floor, excluding 0.5m border around the room. c) High Risk Task Areas, High Risk Task Areas require at least 10% of the normal mains lighting level or a minimum of 15 lux, to be provided within 0.5 seconds of failure of the supply. LUMINAIRE SPACING DATA Verified performance data, including the maximum spacing of luminaires at particular ceiling heights is provided for all Ventilux luminaires. The data is presented in the form of spacing tables similar to the example shown below. In addition this data is available in DIALUX format - please contact the sales office for further details. Luminaires on escape routes should be sited so as not to exceed the maximum spacing distances determined from the table for the particular ceiling height. Light output from signs shall not be considered unless verified photometric data is available. During risk assessment of luminaire positioning, it should be noted that luminaire performance will be adversely affected by the build up of dirt and inadequate maintenance. Existing luminaries should be checked to ensure lamps and lighting controllers are clean, undamaged and that the lamp is not blackened. SYSTEM CHOICE A simple comparison of the relative advantage of each type of system is shown in the following table: 76 Designers’ Information Levels of Illuminance INTRODUCTION TO RISK ASSESSMENT An Emergency Lighting Risk assessment is deemed necessary in premises where people are employed to satisfy the requirements of the Fire Precautions Regulations. The basic risk to be assessed is that in the event of a fire there is adequate means of escape. During a fire condition, the mains lighting is likely to fail, so emergency lighting should be provided to facilitate escape. Emergency Lighting is one of the life safety systems required to be provided, where necessary, in all places of work. The requirement for emergency lighting, its type and location are defined through the risk assessment. THE NEED FOR EMERGENCY LIGHTING RISK ASSESSMENT For premises in which 6 or more persons are employed. there is a legal requirement to document and retain significant findings of the risk assessment and measures proposed to deal with them. If less than 5 persons are employed, there is still a requirement to carry out a risk assessment, although it may not need to be formally recorded. EMERGENCY LIGHTING RISK ASSESSMENT In order to determine whether an emergency lighting installation meets the requirements of all current legislation an assessment is made of the compliance of the installation with current standards and codes of practice. Installations of emergency lighting and signs are deemed to comply with the requirements of the Fire Precautions Regulations if installed in accordance with the governing or national standards controlling emergency lighting, for example IS3217 in Ireland and BS5266 in the UK. REDUCING THE RISK USING ENGINEERING SOLUTIONS Many situations in premises increase the risk of fire and threaten the escape route for people in these situations. There may be simple ways to reduce that risk, for example: A If the incoming mains electrical supply is not in an area of low risk, then staff may be exposed to risk from lighting failure and emergency lighting should be provided to reduce that risk. B If the lighting final circuits do not correspond with the fire compartmentation, then the non-maintained emergency lighting may not operate when required, and maintained emergency lighting should be used to reduce that risk. C If elderly, disabled or partially sighted people are likely to be in the building, they may obstruct the escape routes and higher emergency illuminance of at least 1 Lux* should be provided so that they can see more easily and so that others can help them escape. D If there are potential obstructions on the escape route, then BS5266 and IS3217 advise that they should be lit in colour against a contrasting background. This contrast may not be appropriate, therefore higher emergency illuminance of at least 1 Lux* can be installed to reduce the risk due to obstructions. E If there is likely to be a presence of high physical risk, then a further increase in emergency illuminance and a rapid response time will reduce that risk. F If there is the possibility of arson, then intruder and fire detection and alarm systems in addition to appropriate emergency lighting will reduce that risk. G If the length of the escape route is excessive, then the emergency lighting and signage should be assessed. Higher illuminance or repeat signage may reduce the escape time. H If people such as the public or temporary workers unfamiliar with the layout of the building are likely to be present then high illuminance or more signs may be required. I If the escape route passes through open areas, emergency lighting and signage should be installed. J If an area is larger than 60m, emergency lighting and signage should be installed. K If 5 or more people are employed in the premises, emergency lighting should be provided by an installation of fixed luminaires which are automatically switched on upon failure of normal lighting. 77 78 79 80 81 82 Service & Maintenance 83 Service and Maintenance SERVICE AND MAINTENANCE Once you have decided to specify a Ventilux product, we want to make sure that it gives you trouble free operation. We would be delighted to advise you on the project design, and are available to answer any questions throughout the commissioning period. Once installed, please contact us to discuss a programme of routine maintenance. The information below sets out procedures and responsibilities. Please call our technical helpline if you require clarification or more details. COMMISSIONING Ventilux offers the most comprehensive commissioning service within the industry. Ventilux ensure the system is in full working order and also in compliance with the appropriate regional or national standards. In addition to all this we demonstrate to the end user all the functions of the system. Ventilux have an experienced and knowledgeable team of engineers who are audited by government bodies who commission all the products and systems. MAINTENANCE Ventilux Preventive Maintenance Plans offer inspection of your equipment to identify and correct potential problems before a crisis occurs. Government requirements place obligations on building occupiers/end user to conduct regular and routine tests and inspections of emergency lighting systems. Ventilux ensure your system is in full working order and also in compliance with regional and national standards 84 Service and Maintenance VENTILUX PROVIDE: • Wide range of manufacturers systems supported • Dedicated service & maintenance administration team • Tailored invoicing to suit clients procedures • 365 days a year service engineer response • Experienced engineering team • Computerised service management system • Fully stocked vehicles • One point of contact for all your service and testing requirements • Full Maintenance Report issued as required for governing standards Our comprehensive low-cost maintenance service plans provide coverage for any emergency or failure, with the peace of mind that an authorised factory-trained technician will be on site to address your problem within a matter of hours. Our multi-skilled technicians carry out a detailed analysis of system requirements and prepare programmes of regular checks that help reduce service costs, ensure the value of the product and most importantly ensuring you have emergency lighting coverage in your building when most required. THE EMERGENCY LIGHTING SPECIALISTS PLEASE CONTACT VENTILUX DIRECTLY FOR FURTHER DETAILS. VENTILUX LIMITED VENTILUX UK LIMITED Unit 2, Ashgrove Industrial Estate Kill Avenue, Dun Laoghaire Co. Dublin, Ireland. Tel: (Int) +353 (0) 1 214 8800 Fax: (Int) +353 (0) 1 280 5729 Email: sales@ventilux.ie Unit 20 Britonwood trading Estate, Faraday Road, Knowsley Business Park, Kirkby, Merseyside L33 7UT, UK Tel: (Int) +44 (0) 151 546 4155 Fax: (Int) +44 (0) 151 546 3987 Email: sales@ventilux.co.uk www.ventilux.com 85 Glossary A/h: Amp per hour Anti-Panic (Open) Area Lighting: The part of Emergency Escape Lighting provided to avoid panic and provide illumination allowing people to reach a place where an escape route can be identified. Ballast: The component that controls the operation of a lamp from a specified low or high voltage AC or DC source. Ballast Lumen Factor: The ratio of the light output of the lamp in emergency operation compared with the light output of the same lamp operated by a reference ballast at its rated voltage and frequency. CE Marked: With the CE marking on a product, the manufacturer declares that the product conforms with the essential requirements of the applicable EC directives Central Battery System: A system in which the batteries for a number of emergency luminaires are housed in one location. Usually for all the emergency luminaires on one lighting sub-circuit, but sometimes for all emergency luminaires in a complete building. CREE LED: Cree is a market-leading innovator of lighting-class LEDs, LED lighting, and semiconductor solutions for wireless and power applications. DALI: Digital Addressable Lighting Interface Duration: The period of time, in hours, that the luminaire can maintain continuously the minium level of illuminance required. EMC compliant: Electric Magnetic Compatibility Emergency Exit: The way out of a building, which is intended to be used at any time whilst the premises is occupied. Escape Route Lighting: Lighting provided to ensure that the means of escape to the final EXIT point can be effectively identified and safely used. Emergency Lighting: The lighting provided for use when the supply to the normal mains lighting installation fails. Exit Luminaire: An emergency luminaire designed to serve as an Exit sign. ‘F’ Mark: Mark indicating that a luminaire is suitable for mounting onto normally combustible surfaces. Glow Wire Test: The glow-wire test (850°c) is one of the most important fire-related tests for plastics used in the electrical industry and simulates overheating of wires or components such as resistors or capacitors. ICEL: Industry Committee Emergency Lighting Ingress Protection (IP) Number: Classification of the degree of protection a luminaire provides against the entry of solid foreign bodies and moisture ISO:9001:2008: The ISO 9000 family of standards is related to quality management systems and designed to help organisations ensure that they meet the needs of customers and other stakeholders while meeting statutory and regulatory requirements related to the product. 86 Glossary LED: Light Emitting Diode LIF: Lighting Industry Foundation Lumens: The lumen is the unit of luminous flux, a measure of the total "amount" of visible light emitted by a source. Luminaire: Apparatus which distribute the light given by a lamp or lamps, including all of the items necessary for fixing and protecting the lamps and for connecting them to the electrical supply. Ni-Cd: Nickel Cadmium Battery Ni-Mh: Nickel Metal Hydride Non-Maintained Emergency Luminaire: A luminaire containing one or more lamps, which operate from the emergency supply only upon failure of the normal mains supply. Maintained Emergency Luminaire: A luminaire containing one or more lamps, all of which operate from the normal supply or from the emergency supply at all material times. Mounting Height: The vertical distance between the underside of the luminaire or base of a sign and the working plane. Note: For emergency lighting the floor is always taken to be the working plane. NSAI: National Standard Authority of Ireland Photometric Data: Photometric Data is often used to simulate lighting designs for projects before they are built or renovated. This enables architects, lighting designers, and engineers to determine whether a proposed lighting setup will deliver the amount of light intended. They will also be able to determine the contrast ratio between light and dark areas. Self Contained Emergency Luminaire: A luminaire or sign providing Maintained or Non-Maintained emergency lighting, in which all the elements such as battery, the lamp and the control unit are contained within the housing or within 1 metre of the housing. Slave Luminaire: An emergency luminaire without its own batteries, which is designed to work in conjunction with a central battery system. Combined/Sustained Emergency Luminaire: A luminaire containing two or more lamps, at least one of which is energised from the emergency supply and the remainder from the normal supply VA: Volt-ampere (VA) is a measurement of power in a direct current ( DC ) electrical circuit. DISCLAIMER While every care has been taken to ensure accuracy in the production of this ‘Buyer’s Guide’ we take no responsibility for any errors or omissions. E & OE. © VENTILUX LIMITED 87 Ventilux Conversion Codes DOWNLIGHTS/ PL TYPE FITTINGS 5/7/9WPLS DOWNLIGHT OR BULKHEAD 11WPLS 18WPLL 24WPLL 36WPLL 40WPLL 55WPLL 80WPLL 10W PL-C/PL-T/TC-D/TC-T 13W PL-C/PL-T/TC-D/TC-T 18W PL-C/PL-T/TC-D/TC-T 26W PL-C/TC-D 26W PL-T/TC-T 32W PL-T/TC-T 42W PL-T/TC-T 57W PL-T/TC-T T5 MODULARS/CORROSSION PROOFS/BATTENS 14WT5/T16 21WT5/T16 24WT5/T16 28WT5/T16 35WT5/T16 39WT5/T16 49WT5/T16 54WT5/T16 55WT5 (CIRCULAR) 80WT5/T16 MODULARS/CORROSSION PROOFS/BATTENS 18W T8/T26 30W T8/T26 36W T8/T26 58W T8/T26 70W T8/T26 2D CIRCULARS/SQUARES 16W2D 21W2D 28W2D 38W2D 55W2D LOW VOLTAGE 12V 20W HALOGEN 12V 35W HALOGEN 12V 50W HALOGEN 12V 75W HALOGEN 12V 100W HALOGEN VENTILUX IN-HOUSE CONVERSION FPHFM3/18/R FPHFM4/58/R FPHFM3/18 FPHFM4/58/R FPHFM4/58 FPHFM4/28 ZFPHFM655 FPMAC6/80 (SLIMLINE BOARD) FPHFM3/18/R FPHFM4/58/R FPHFM4/58/R FPHFM4/58/R FPHFM6/42/R FPHFM6/42/R FPHFM6/42/R FPHFM6/42/R VENTILUX IN-HOUSE CONVERSION FPHFM4/14/T5 FPHFM4/14/T5 FPHFM4/24/T5 FPHFM6/28/T5 FPHFM6/35/T5 FPHFM6/39/T5 FPHFM6/49/T5 FPHFM6/54/T5 FPHFM6/60/R FPHFM6/80/T5 VENTILUX IN-HOUSE CONVERSION FPHFM3/18 FPHFM4/58 FPHFM4/58 FPHFM4/58 FPHFM5/70 VENTILUX IN-HOUSE CONVERSION FPH-4-16 FPHFM4/28/R FPNCEM4/28 FPHFM5/38/R FPH6/42/R (SLIMLINE GEAR) VENTILUX IN-HOUSE CONVERSION FPTH20/NM3 FPTH50/M3 FPTH50/M3 FPTH100/NM or M3 FPTH100/NM or M3 88 VENTILUX CONVERSION KITS KPHFM3/18/R KPHFM4/58/R KPHFM3/18 KPHFM4/58/R KPHFM4/58 KPHFM4/28 KPHFM655 KPMAC6/80 (SLIMLINE BOARD) KPHFM3/18/R KPHFM4/58/R KPHFM4/58/R KPHFM4/58/R KPHFM6/42/R KPHFM6/42/R KPHFM6/42/R KPHFM6/42/R VENTILUX CONVERSION KITS KPHFM4/14/T5 KPHFM4/14/T5 KPHFM4/24/T5 KPHFM6/28/T5 KPHFM6/35/T5 KPHFM6/39/T5 KPHFM6/49/T5 KPHFM6/54/T5 KPHFM6/60/R KPHFM6/80/T5 VENTILUX CONVERSION KITS KPHFM3/18 KPHFM4/58 KPHFM4/58 KPHFM4/58 KPHFM5/70 VENTILUX CONVERSION KITS KPH-4-16 KPHFM4/28/R KPNCEM4/28 KPHFM5/38/R KPH6/42/R (SLIMLINE GEAR) VENTILUX CONVERSION KITS KPTH20/NM3 KPTH50/M3 KPTH50/M3 KPTH100/NM or M3 KPTH100/NM or M3 Ventilux Parts BATTERIES Ni-CAD STICKS 2 CELL Ni-CAD STICK 3 CELL Ni-CAD STICK 4 CELL Ni-CAD STICK 5 CELL Ni-CAD STICK 6 CELL Ni-CAD STICK Ni-CAD PACKS 2 CELL Ni-CAD PACK 3 CELL Ni-CAD PACK 4 CELL Ni-CAD PACK 5 CELL Ni-CAD PACK 6 CELL Ni-CAD PACK 8 CELL Ni-CAD PACK 10 CELL Ni-CAD PACK Ni-MH STICKS 2 CELL Ni-MH STICK 3 CELL Ni-MH STICK 4 CELL Ni-MH STICK 5 CELL Ni-MH STICK 6 CELL Ni-MH STICK NI-MH PACKS 2 CELL Ni-MH PACK 3 CELL Ni-MH PACK 4 CELL Ni-MH PACK 5 CELL Ni-MH PACK 6 CELL Ni-MH PACK SEALED LEAD ACID (SLA) 6V 12AH 12V 2.1AH 12V 2.8AH 12V 7AH 6V 2.8AH VENTILUX PART CODE 70223 70170 70123 70125 70128 70230 70122 70184 70101 Z1746 70134 70129 70231 70232 70233 70234 70235 PLEASE ASK SALES PLEASE ASK SALES PLEASE ASK SALES 70237 70236 70133 70216 70220 70162 70114 ACCESSORIES 28W 2D BALLAST GREEN CHARGER LED (1METRE) CEM BALLAST/MODULE 28W2D (Combined Electronic) 28W 2D LAMP 8 WATT LAMP 12V 21 WATT LAMP EMERGENCY MODULES VENTILUX PART CODE 90110 10520 70116 20235 20124 Z1815 VENTILUX PART CODE 13016 13015 13017 13017 13014 00102 00105MO 13043 13043 13028 13044 13044 13044 13042 HFM3/18 HFM3/36 HFM4/14 HFM4/28 HFM4/58 HFM5/38 HFM5/70 HFM6/28 HFM6/35 HFM6/42 HFM6/49 HFM6/54 HFM6/80 HFM6/55 89 Notes 90 Notes 91 Notes 92 Notes 93 Notes 94 Escape Route The robust and durable design of the (IP65) WP Bulkhead Luminaire makes it ideal for a range of exterior and selected interior locations. Operators of leisure centres, car parks, sports facilities, factories and underground walkways will benefit from its tough, vandal resistant construction and ease of installation. Fire Protection WPEquipment Bulkhead The WP range includes a flame retardant ABS body and Ventilux a full-service Fire Protection supplier that has built a solid reputation includes anis Opal diffuser as standard. based on our commitment to provide only the highest quality products and The luminaires in the WP range are available either for outstanding service. emergency lighting or mains illumination and conform fully with European Standards. We provide an extensive line of fire protection equipment which include: View From 22M · Fire Panels · Break Glass Units · Smoke Detectors · Heat Detectors · Bells · Sounders · Product DoorCode Retainers Mode of Lamp Battery Lumen VA Weight operation Escape Route WPM3/F8 WPNM3/F8 WPS3/F8 WPM3/LED/1W WPNM3/LED/1W WPM3/LED/3W WPNM3/LED/3W M N-M Sustained M N-M M N-M T5-8 Watt T5-8 Watt T5-8 Watt 1 Watt LED 1 Watt LED 3 Watt LED 3 Watt LED 2.4V/4.5A/h 2.4V/4.5A/h 2.4V/4.5A/h 4.8V/1.3A/h 4.8V/1.3A/h 4.8V/1.3A/h 4.8V/1.3A/h 78 87 87 TBC TBC TBC TBC TBC 1.9kg 1.6kg 1.8kg TBC TBC TBC TBC Exit Signage WPM3/F8/EXIT WPNM3/F8/EXIT WPM3/LED/EXIT WPNM3/LED/EXIT M N-M M N-M T5-8 Watt T5-8 Watt 1 Watt LED 1 Watt LED 2.4V/4.5A/h 2.4V/4.5A/h 4.8V/1.3A/h 4.8V/1.3A/h N/A N/A N/A N/A TBC TBC TBC TBC Specify /MFR for internal mains failure hold off relay M denotes Maintained, N-M denotes Non-Maintained Specify 24 / 50 / 110 / 230 Volts AC/DC System Voltage Ventilux has a full extensive range that is certified For other durations, specify the required time period e.g. / NM3 becomes / NM1 for 1 hour duration to national standards. Ventilux can also fully service and commission fire safety panels and systems to give complete customer peace of mind. • Dimensions: 368 x 150 x 102 (mm) • Opal diffuser as standard, Prismatic diffuser also available Our• staff are committed White finish as standardto exceptional customer service and rapid • Available in chrome/CH, brass/BR and other colours on request • Sticker legends (page ?) If you have a need for fire protection equipment call us today! • Also available with NETCOM 5XP or DALI addressable • Available with auto test / push test function 95 delivery to exceed your expectations. THE EMERGENCY LIGHTING SPECIALISTS W W W. V E N T I L U X . CO M D I S T R I B U T E D BY :