Bulletin 817 Thermistor Protection Relay 6 Bulletin 817 • Accurate Temperature Monitoring for Critical Applications • Automatic, Manual and Remote Reset • Status Indicating LEDs • DIN Rail or Panel Mounting • Guarded Terminals IP20 • 1 N.O. and 1 N.C. Output Contacts as Standard • No Set-Up or Adjustments Required for Installation TABLE OF CONTENTS Description Page Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-15 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-15 Description Page Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-16 Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-18 Description Bulletin 817 Thermistor Protection relays, utilized in conjunction with PTC thermistor sensors, provide accurate temperature monitoring in critical applications and severe environments such as widely varying temperatures and impeded ventilation and cooling. Conformity to Standards: Approvals: IEC 255-8, IEC 292-1 SEV IEC 255-4, IEC 69 NEMKO SEV, SEN 36 1503 PTB CSA C22.2 No. 14 FI Your order must include: UL 508 CSA Certified • Cat. No. of the relay selected with Voltage Suffix Code. UL Recognized 6-14 Bulletin 817 Thermistor Protection Relay Product Overview Model Cat. No. 817-A⊗ Cat. No. 817-M⊗ Cat. No. 817-U⊗ Overtemperature protection Short-circuit and open-circuit protection for sensor measuring circuit Trip indication (red LED) Automatic reset Manual reset Remote reset (external button) Storage of status in event of power failure for more than 3 hours at +25°C (77°F) unlimited (not temperature-dependent) “Test” button Power-on indication (green LED) ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ = Standard feature ⊗ = Cat. No. is incomplete. Refer to Product Selection below. Product Selection Cat. No. 817-A⊗ Cat. No. 817-M⊗ Cat. No. 817-U⊗ Description ❋ Cat. No. Thermistor Protection relay 817-A⊗ Thermistor Protection relay plus manual/remote reset 817-M⊗ Thermistor Protection Relay plus manual/remote reset test function and power indication LED 817-U⊗ ⊗ Voltage Suffix Code Cat. No. as listed is incomplete. Select a Voltage Suffix Code from the table below to complete the Cat. No. Example: Cat. No. 817-A⊗ for 24V, 50 Hz becomes Cat. No. 817-AKD. Voltage 24V 48V 110V 220V 240V 380V 415V 440V 50 Hz 60 Hz DC KD KD Z24 KH KH Z48 D D – A A – AJ AJ – KK KK – I I – GB GB – Specifications – Page 6-16 Approximate Dimensions – Page 6-18 ❋ Prices – Consult Sales Office or price list 6-15 Bulletin 817 Thermistor Protection Relay Specifications Electrical Rated Voltage Test Voltage Between separated circuits Acc. to IEC 255-8 440V Acc. to SEV 380V Alternating current acc. to IEC 292-1 Surge voltage acc. to IEC 255-4 and SEN 36 1503 Interference voltage acc. to ANSI ➋ C 37.90 a1974, IEC 255-6 and SEN 36 1503 AC Rated supply voltage Us AC Permissible Fluctuations Power consumption Output Relay Contact Data Contacts (electrically isolated) Operating voltage ➌ [V] 24 48 Continuous thermal current [A] 4 4 Rated operational current with AC AC-11 [A] 4 4 Rated operational current with DC DC-11 without protection circuit, L/R = 35 ms [A] 0.6 0.3 with protection circuit ➍, L/R = 100 ms [A] 0.6 0.6 Max. perm. make/break current [A] 44 44 Rated current of back-up fuse: Max. fast-acting 16A; slow-blow 10A Mechanical Vibration Resistance According to IEC 68 (10 – 150 Hz) mm2 AWG m Maximum length ➎ (ft) Cat. No. 817-A⊗ Reset Cat. No. 817-M⊗ Cat. No. 817-U⊗ Measuring Line Minimum cross-section Remote Reset with Cat. No. 817-M⊗, 817-U⊗ ➊ ➋ ➌ ➍ ➎ ➏ 6-16 24, 48V 0.8…1.1 Us 50/60 Hz DC 0.9…1.2 Us AC 2.5VA (2.2W) DC 2.2W 1 make and 1 break 220 240 380 4 4 4 3 3 2 110 4 4 0.25 0.5 44 0.15 0.5 44 0.05 0.5 33 0.5 20 200 (656.2) Automatic Manual or automatic ➏ Manual or automatic ➏ External contact at r1-r2 0.05 0.5 33 – – 22 415 4 2 440 4 1.5 – – 22 – – 16.5 3g 30g, shock duration 18 ms, semi-sinusoidal in the 3 directions x, y, and z According to IEC 68-2-27 or DIN 40 046/7 0.75 1 1.5 2.5 18 300 (984.25) 16 400 (1312.3) 14 600 (1968.5) 14 1000 (3208.8) Max. line length for remote reset Rated insulation voltage: 300V. American National Standards Institute. According to CSA, UL: pilot duty 240V (B 300). For more technical information, consult Allen-Bradley Sales Office. Bulletin 817 to motor; installation: up to 200m not shielded. For automatic reset: connect r1-r2. Product Selection – Page 6-15 110, 220, 240, 380, 415, 440V 50/60 Hz Special Us 24, 48V 50/60 Hz AC 60 4 4 250V 240V 2.5 kV, 1 MHz, 2 s DC Supply Impact Resistance According to AS, BS, VDE 0660 According to CSA, UL ➊ 2.5 kV, 50/60 Hz, 1 min. 5 kV, 1.2/50 µs Potential-free make contact Up to 300m (984.25 ft) shielded Up to 1000m (3280.8 ft) shielded Bulletin 817 Thermistor Protection Relay Specifications, Continued Environmental 4000 1330 550 250 100 20 10 -20°C 0°C TNF-20K TNF- 5K TNF+15K TNF+ 5K TNF Max. cold resistance of PTC sensor chain Max. number of series connected PTC sensors acc. to IEC 34-11-2 Response level ϑ A = –25°C (13°F)…+60°C (140°F) Reset level ϑ A = –25°C (13°F)…+60°C (140°F) Response level with short circuit in sensor circuit ϑ A = –25°C (13°F)…+60°C (140°F) Measuring voltage acc. to IEC 34-11-2 Normal operation Ambient Temperature Storage (in dry rooms) According to IEC 68-2-3 humid Climatic Classification heat PTC sensor characteristic According to IEC-34-11-2 1500 Ω 6 3300 Ω ± 300 Ω 1800 Ω ± 300 Ω ≤ 15 Ω DC < 2.5V –25°C (–13°F)…+60°C (140°F) –40°C (–40°F)…+60°C (140°F) 40°C (104°F), 92% rel. humidity, 56 days TNF: Rated response temperature At 25°C (77°F) > 3h Trip memory In event of power supply failure (zero-voltage safe-guard) Cat. No. 817-M⊗ At 40°C (104°F) > 1h Cat. No. 817-U⊗ Unlimited (not temperature-dependent) Storage Time At 60°C (140°F) > 15 min. Construction Open Terminals Captive 2 x 2.5 mm2 (.0039 in2) single wire or Terminals Connection wire cross-sections 2 x 1.5 mm2 (.0023 in2) with end ferrule Protection class according to IEC 529 Device (less terminals) IP30 Terminals (acc. to VBG 4) IP20 Installation Bulletin 817 Thermistor Protection relay is designed for surface mounting with screw fixing according to hole plan EN 50 002 or for snap-on fixing to a top hat rail EN 50 022'-35 x 7.5. Arrangement, assignment and marking of terminals in accordance with EN 50 005. The mounting position of the Bulletin 817 does not influence its function. 360° 360° Typical Wiring Diagram Terminal and block circuit diagram of Bulletin 817 Terminal and Block Circuit Diagram T1 T2 PTC Temperature Sensor Us A1(+) 13 Thermal Trip Output Relay Cat. No.817-A ,-M ,-U 14 21 Supply 22 A2(–) r1 Cat. No.817-M ,-U Reset Button Remote Reset ➊ Cat. No.817-U Trip Memory for Power Supply Failure Supply Indication Test Button r2 ➊ For automatic reset available in Cat. No. 817-M⊗ and Cat. No. 817-U⊗, connect r1-r2. Product Selection – Page 6-15 6-17 Bulletin 817 Thermistor Protection Relay Specifications/Approximate Dimensions Application Example Starter (Bulletin 100 and Bulletin 193) with additional Bulletin 817. Legend K1 F1 F2 S1 S0 S2 Us Bulletin 100 contactor Bulletin 193 thermal overload relay Bulletin 817 Thermistor Protection relay ON button OFF button Remote button reset H1 H2 B1 Signal Lamp “Contactor ON” Signal Lamp “Bulletin 817 tripped” Thermistor in protected object Circuit Diagram Main Circuit Control Circuit Impulse Contact Control L1 F7 Us AC L1 L2 21 S0 L3 N 22 13 S1 PE K1 14 14 S2 Supply voltage F9 A1 r1 1 3 5 2 4 6 2 ) r2 K1 A2 F2 Bulletin 817 2 4 21 A1 14 22 A2 T1 T2 6 T2 97 95 98 96 F1 B1 H2 H1 A1 M The contacts 13…14 and 21…22 of the output relay are drawn in their power-off position A1…A2. 13 F2 Bulletin 817 F1 K1 M1 3 B1 N +t (L2/F8) A2 Approximate Dimensions Position of terminals r1 and r2 are not available on Cat. No. 817-A (1-3/8) 35 (1-3/8) 14 22 r1 r2 (–)A2 70 ➊ (2-3/4) 60 (2-23/64) 50 (1-31/32) Hole plan 45 (1-3/4) ➊ For Top Hat Rail 35mm to EN 50 022, Cat. No. 199-DR1. Product Selection – Page 6-15 6-18 T2 21 T1 A1(+) 4.8 (3/16) 13 Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 35 13 7 (9/32) 5 (13/64) 95.5 (3-3/4) 95.5 (3-3/4) PTC