1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f ARCHITECT RNL 1050 17th Street, Suite A200 Denver, CO 80625 303.295.1717 CIVIL JORGENSEN ASSOCIATES PO Box 9550 1315 South Highway 89, Suite 203 Jackson, WY 83001 307.733.5150 LANDSCAPE RNL 1050 17th Street, Suite A200 Denver, CO 80625 303.295.1717 STRUCTURAL MONROE & NEWELL 1400 Glenarm Place, Suite 101 Denver, CO 80202 303.623.4927 MECHANICAL M E GROUP 707 17th Street, #3000 Denver, CO 80202 303.382.1920 ELECTRICAL M E Group 707 17th Street, #3000 Denver, CO 80202 303.382.1920 MAINTENANCE EQUIPMENT MAINTENANCE DESIGN GROUP 1600 Stout Street, Suite 940 Denver, CO 80202 303.302.0266 FUEL SYSTEMS FUEL SOLUTIONS INC 12340 Santa Monica Blvd, Suite 133 Los Angeles, CA 90025 310.207.8548 SUSTAINABILITY AMBIENT ENERGY 130 West 5th Avenue Denver, CO 80204 303.278.1532 CHECKED BY: Checker 4/5/2013 2:56:55 PM DRAWN BY: Author C:\Users\shamilton\Desktop\Revit Local\2013\3123_STARTBus_Arch_shamilton.rvt DESIGN DEVELOPMENT VOLUME 2 of 2 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY DESIGN DEVELOPMENT 8 APRIL 2013 JACKSON, WYOMING 5 6 7 8 9 10 11 12 13 SHEET NO. 14 15 INDEX OF DRAWINGS SHEET NAME SHEET NO. VOLUME 1 01-GENERAL INFORMATION G001-1 ABBREVIATIONS, SHEET INDEX, & SYMBOLS G101 LIFE SAFETY PLAN LEVEL 1 G102 LIFE SAFETY PLAN LEVEL 2 & 3 G201 3D VIEWS G202 PERSPECTIVE N M L K 05 - CIVIL C001 C101 C201 C301 C302 C303 C401 C501 C601 C602 C701 C702 C703 C704 CIVIL NOTES, LEGEND EXISTING CONDITIONS SITE PLAN OVERVIEW ROAD PLAN & PROFILE ROAD PLAN & PROFILE ROAD PLAN & PROFILE UTILITY PLAN TRAFFIC FLOW AND STRIPING RETAINING WALL PLAN RETAINING WALL PLAN DETAILS DETAILS DETAILS DETAILS 06-LANDSCAPE L101 L102 L201 L301 L302 L303 L304 L305 OVERALL LAYOUT PLAN ENTRY PLAZA LAYOUT PLAN OVERALL PLANTING PLAN DETAILS DETAILS SECTIONS SECTIONS DETAILS - PLANTING 07-STRUCTURAL S000 S001 S002 S003 S101 S102 S103 S111 S112 S113 S114 S115 S116 S117 S121 S122 S123 S125 S131 S132 S133 S134 S135 S136 S137 S200 S300 S301 S302 S303 S304 S400 J I H F E D C 17 18 INDEX OF DRAWINGS SHEET NAME VOLUME 2 01-GENERAL INFORMATION G001-2 SHEET INDEX - VOLUME 2 GENERAL NOTES FOUNDATION DETAILS FOUNDATION DETAILS FOUNDATION DETAILS OVERALL FOUNDATION PLAN OVERALL LEVEL 2 AND FRAMING PLAN OVERALL ROOF FRAMING PLAN FOUNDATION PLAN AREA A FOUNDATION PLAN AREA B FOUNDATION PLAN AREA C FOUNDATION PLAN AREA D FOUNDATION PLAN AREA E FOUNDATION PLAN AREA F CNG FOUNDATION PLAN LEVEL 2 FLOOR FRAMING PLAN AREA A LEVEL 2 CRANE RAIL LEVEL 2 FLOOR FRAMING PLAN AREA C LEVEL 2 FLOOR FRAMING PLAN AREA E ROOF FRAMING PLAN AREA A ROOF FRAMING PLAN AREA B ROOF FRAMING PLAN AREA C ROOF FRAMING PLAN AREA D ROOF FRAMING PLAN AREA E ROOF FRAMING PLAN AREA F CNG ROOF FRAMING PLAN FRAMING DETAILS FRAMING DETAILS FRAMING DETAILS FRAMING DETAILS TRUSS #1 PROFILE TRUSS #2 PROFILE MASONRY DETAILS 08-ARCHITECTURE A101 LEVEL 1 FLOOR PLAN A102 LEVEL 2 & 3 FLOOR PLAN A103 ROOF PLAN A104 LEVEL 1 RCP A105 LEVEL 2 & 3 RCP A111 LEVEL 1 FLOOR PLAN AREA A A112 LEVEL 1 FLOOR PLAN AREA B A113 LEVEL 1 FLOOR PLAN AREA C A114 LEVEL 1 FLOOR PLAN AREA D A115 LEVEL 1 FLOOR PLAN AREA E A116 LEVEL 1 FLOOR PLAN AREA F A117 LEVEL 1 FLOOR PLAN & ROOF PLAN - CNG A121 LEVEL 2 FLOOR PLAN AREA A A123 LEVEL 2 FLOOR PLAN AREA C A124 LEVEL 2 FLOOR PLAN AREA D A125 LEVEL 2 & 3 FLOOR PLAN AREA E A126 LEVEL 2 FLOOR PLAN AREA F A131 ROOF PLAN AREA A A132 ROOF PLAN AREA B A133 ROOF PLAN AREA C A134 ROOF PLAN AREA D A135 ROOF PLAN AREA E A136 ROOF PLAN AREA F A141 LEVEL 1 RCP AREA A A142 LEVEL 1 RCP AREA B A143 LEVEL 1 RCP AREA C A144 LEVEL 1 RCP AREA D A145 LEVEL 1 RCP AREA E A146 LEVEL 1 RCP AREA F A151 LEVEL 2 RCP AREA A A153 LEVEL 2 RCP AREA C A155 LEVEL 2 & 3 RCP AREA E A201 EXTERIOR BUILDING ELEVATIONS A202 EXTERIOR BUILDING ELEVATIONS A203 EXTERIOR BUILDING ELEVATIONS - CNG & CANOPIES A211 INTERIOR ELEVATIONS A212 LOBBY ELEVATIONS A213 HOUSING ELEVATIONS A214 INTERIOR ELEVATIONS A301 BUILDING SECTIONS A311 WALL SECTIONS A312 WALL SECTIONS A313 WALL SECTIONS A314 WALL SECTIONS A315 WALL SECTIONS A316 WALL SECTIONS A317 WALL SECTIONS A318 WALL SECTIONS A401 ENLARGED PLANS A402 VERTICAL CIRCULATION A403 VERTICAL CIRCULATION A404 ENLARGED PLANS A511 TYPICAL DETAILS A601 DOOR SCHEDULE A603 FINISH SCHEDULE AND LEGEND A605 TYPICAL FIXTURE MOUNTING HEIGHTS AF101 LEVEL 1 FINISH PLAN G 16 N 10-EQUIPMENT EQ001 EQ101 EQ104 EQ111 EQ112 EQ113 EQ114 EQ117 EQ124 EQ141 EQ142 EQ143 EQ144 EQ501 EQ502 EQUIPMENT SCHEDULE AND NOTES OVERALL EQUIPMENT LAYOUT PLAN OVERALL OVERHEAD EQUIPMENT LAYOUT PLAN EQUIPMENT LAYOUT BUS STORAGE AND WASH EQUIPMENT LAYOUT BUS STORAGE EQUIPMENT LAYOUT DRIVE AISLE EQUIPMENT LAYOUT VEHICLE MAINTENANCE EQUIPMENT LAYOUT CNG BUILDING EQUIPMENT LAYOUT MEZZANINE LEVEL OVERHEAD EQUIPMENT LAYOUT BUS STORAGE AND WASH OVERHEAD EQUIPMENT LAYOUT BUS STORAGE OVERHEAD EQUIPMENT LAYOUT DRIVE AISLE OVERHEAD EQUIPMENT LAYOUT VEHICLE MAINTENANCE EQUIPMENT DETAILS & ENLARGED PLANS EQUIPMENT DETAILS & ENLARGED PLANS 12-PLUMBING P-101 P-102 P-103 P-104 P-105 P-106 P-111 P-112 P-113 P-114 P-115 P-116 P-117 P-121 P-122 P-123 P-124 P-125 P-126 P-131 P-132 P-133 P-134 P-135 P-136 P-401 P-501 P-601 UNDERFLOOR - PLUMBING PLAN - AREA A UNDERFLOOR - PLUMBING PLAN - AREA B UNDERFLOOR - PLUMBING PLAN - AREA C UNDERFLOOR - PLUMBING PLAN - AREA D UNDERFLOOR - PLUMBING PLAN - AREA E UNDERFLOOR - PLUMBING PLAN - AREA F LEVEL 1 - PLUMBING PLAN - AREA A LEVEL 1 - PLUMBING PLAN - AREA B LEVEL 1 - PLUMBING PLAN - AREA C LEVEL 1 - PLUMBING PLAN - AREA D LEVEL 1 - PLUMBING PLAN - AREA E LEVEL 1 - PLUMBING PLAN - AREA F LEVEL 1 - PLUMBING PLAN - CNG BUILDING LEVEL 2 - PLUMBING PLAN - AREA A LEVEL 2 - PLUMBING PLAN - AREA B LEVEL 2 - PLUMBING PLAN - AREA C LEVEL 2 - PLUMBING PLAN - AREA D LEVEL 2 - PLUMBING PLAN - AREA E LEVEL 2 - PLUMBING PLAN - AREA F ROOF - PLUMBING PLAN - AREA A ROOF - PLUMBING PLAN - AREA B ROOF - PLUMBING PLAN - AREA C ROOF - PLUMBING PLAN - AREA D ROOF - PLUMBING PLAN - AREA E ROOF - PLUMBING PLAN - AREA F ENLARGED PLUMBING PLANS PLUMBING DETAILS PLUMBING SCHEDULES 13-PROCESS DG001 DG101 DG102 DG601 DG611 DL001 DL101 DL511 DL601 DL611 DL612 DL711 CNG FUELING NOTES FUEL SYSTEMS SITE PLAN CNG FUEL EQUIPMENT PLAN CNG FUEL EQUIPMENT SCHEDULE CNG PIPING FLOW DIAGRAM PETROL FUELING NOTES PETROL FUEL EQUIPMENT PLAN PETROL FUEL DETAILS 1 PETROL FUEL EQUIPMENT SCHEDULE DIESEL PIPING FLOW DIAGRAM GASOLINE PIPING FLOW DIAGRAM LINE VOLTAGE DIAGRAM 14-MECHANICAL M-000 M-111 M-112 M-113 M-114 M-115 M-116 M-117 M-121 M-122 M-123 M-124 M-125 M-126 M-133 M-135 M-136 M-137 M-141 M-142 M-143 M-144 M-145 M-146 M-151 M-152 M-153 M-154 M-155 M-156 M-301 M-302 M-401 M-501 M-502 M-503 M-601 M-602 MECHANCIAL LEGEND AND NOTES LEVEL 1 - HVAC PLAN - AREA A LEVEL 1 - HVAC PLAN - AREA B LEVEL 1 - HVAC PLAN - AREA C LEVEL 1 - HVAC PLAN - AREA D LEVEL 1 - HVAC PLAN - AREA E LEVEL 1 - HVAC PLAN - AREA F LEVEL 1 - HVAC PLAN - CNG BUILDING LEVEL 2 - HVAC PLAN - AREA A LEVEL 2 - HVAC PLAN - AREA B LEVEL 2 - HVAC PLAN - AREA C LEVEL 2 - HVAC PLAN - AREA D LEVEL 2 - HVAC PLAN - AREA E LEVEL 2 - HVAC PLAN - AREA F ROOF - MECHANICAL PLAN - AREA C ROOF - MECHANICAL PLAN - AREA E ROOF - MECHANICAL PLAN - AREA F ROOF - MECHANICAL PLAN - CNG BUILDING LEVEL 1 - HYDRONIC PLAN - AREA A LEVEL 1 - HYDRONIC PLAN - AREA B LEVEL 1 - HYDRONIC PLAN - AREA C LEVEL 1 - HYDRONIC PLAN - AREA D LEVEL 1 - HYDRONIC PLAN - AREA E LEVEL 1 - HYDRONIC PLAN - AREA F LEVEL 2 - HYDRONIC PLAN - AREA A LEVEL 2 - HYDRONIC PLAN - AREA B LEVEL 2 - HYDRONIC PLAN - AREA C LEVEL 2 - HYDRONIC PLAN - AREA D LEVEL 2 - HYDRONIC PLAN - AREA E LEVEL 2 - HYDRONIC PLAN - AREA F MECHANICAL DIAGRAMS HYDRONIC ZONING PLAN ENLARGED MECHANICAL PLANS MECHANICAL DETAILS MECHANICAL DETAILS MECHANICAL DETAILS MECHANICAL SCHEDULES MECHANICAL SCHEDULES 15-ELECTRICAL E-000 E-001 E-111 E-112 E-113 E-114 E-115 E-116 E-117 E-121 E-123 E-125 E-133 E-135 E-136 E-137 E-141 E-142 E-143 E-144 E-145 E-146 E-147 E-151 E-153 E-155 E-301 E-302 E-601 E-602 ELECTRICAL LEGEND AND NOTES ELECTRICAL SITE PLAN LEVEL 1 - POWER PLAN - AREA A LEVEL 1 - POWER PLAN - AREA B LEVEL 1 - POWER PLAN - AREA C LEVEL 1 - POWER PLAN - AREA D LEVEL 1 - POWER PLAN - AREA E LEVEL 1 - POWER PLAN - AREA F LEVEL 1 - POWER PLAN - CNG BUILDING LEVEL 2 - POWER PLAN - AREA A LEVEL 2 - POWER PLAN - AREA C LEVEL 2 - POWER PLAN - AREA E ROOF - POWER PLAN - AREA C ROOF - POWER PLAN - AREA E ROOF - POWER PLAN - AREA F ROOF - CNG BUILDING LEVEL 1 - LIGHTING PLAN - AREA A LEVEL 1 - LIGHTING PLAN - AREA B LEVEL 1 - LIGHTING PLAN - AREA C LEVEL 1 - LIGHTING PLAN - AREA D LEVEL 1 - LIGHTING PLAN - AREA E LEVEL 1 - LIGHTING PLAN - AREA F LEVEL 1 - LIGHTING PLAN - CNG BUILDING LEVEL 2 - LIGHTING PLAN - AREA A LEVEL 2 - LIGHTING PLAN - AREA C LEVEL 2 - LIGHTING PLAN - AREA E ELECTRICAL ONE-LINE DIAGRAM ELECTRICAL ONE-LINE DIAGRAM ELECTRICAL SCHEDULES ELECTRICAL SCHEDULES L K J I H G F E D NOT FOR CONSTRUCTION C B B 1 DESIGN DEVELOPMENT No REVISION/SUBMISSION 4/8/13 DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: 3123 CHECKED BY: Checker SHEET INDEX VOLUME 2 A A 4/8/2013 10:37:56 AM DRAWN BY: Author C:\Users\shamilton\Desktop\3123_STARTBus_Arch_shamilton(Recovery).rvt M DESIGN DEVELOPMENT 4 JACKSON, WYOMING 3 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f 2 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 G001-2 EQ ID # 11071 11081 11351 11401 11402 12001 12201 14251 14501 14502 14503 14511 14512 14513 14541 14591 15601 15701 16881 16882 18611 20201 20401 20751 20761 21051 21061 21911 22051 22201 23441 23601 24401 24501 25501 26381 26391 26401 26901 26981 29141 29151 29161 29201 29351 29401 32751 35401 37181 49051 CABINET, DRAWER, RED CABINET, DRAWER CABINET, FILE, LEGAL, 4 DRAWER CABINET, FLAMMABLE MATERIALS, LARGE CABINET, FLAMMABLE MATERIALS, LARGE CART, PARTS DESK, STAND-UP, WALL MOUNTED RACK, ARM, SINGLE FACE BIN, BOLT BINS, BOLT, HYDRAULIC FITTINGS BINS, BOLT, HYDRAULIC FITTINGS BOLT BIN BOLT BIN BOLT BIN RACK, STORAGE, FAN BELT SHELVING UNIT, 48" RACK, HOSE, FABRICATED RACK, SPOOL, WIRE, WALL MOUNTED SHELVING UNIT SHELVING UNIT WORKBENCH ANVIL WITH STAND CHARGER, BATTERY BUFFER/GRINDER, 6", BENCH MOUNTED GRINDER, 6", WITH PEDESTAL CADDY, TRANSFER, FUEL, GAS CADDY, TRANSFER, FUEL, GAS CRIMPER, FITTINGS/HOSE, ELECTRIC/HYDRAULIC DRILL PRESS DRILL PRESS IRON WORKER LATHE, BRAKE DRUM CHANGER, TIRE, AUTO/LIGHT TRUCK CHANGER, TIRE, BUS/LARGE TRUCK PRESS, AIR/HYDRAULIC, 55 TON RECYCLER SYSTEM, ENGINE COOLANT RECYCLER SYSTEM, ATF REFRIGERANT RECLAMATION SYSTEM, PORTABLE SAW, BAND, HORIZONTAL SAW, CUTOFF, ABRASIVE WELDER, MIG, PORTABLE CUTTER, PLASMA WELDER, MIG, PORTABLE WELDER, OXYACETYLENE, WITH CART WELDER, STICK, AC/DC WELDER, TIG PORTABLE FILTER ARM TANK, PARTS CLEANING WASHER, HI PRESSURE/HOT WATER, NG BALANCER, WHEEL, ELECTRONIC LUBRICATION FLUID PIPING SCHEDULE FLUID TYPE PIPE TYPE MINIMUM WALL THICKNESS SPEC FURNISH SECTION INSTALL 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI DESCRIPTION FITTING TYPE JOINT TYPE ASTM A/ASME SA-179 SEAMLESS STEEL TUBING 3/4" 1" 1-1/4" = = = 0.049 0.065 0.083 SAE J1065 HYDRAULIC TUBE FITTINGS 1,000 PSI COMPRESSION 1,000 PSI CHASSIS GREASE (CG) ASTM A/ASME SA-179 SEAMLESS STEEL TUBING 3/4" 1" 1-1/4" = = = 0.116 0.156 0.188 SAE J1065 HYDRAULIC TUBE FITTINGS 4,000 PSI COMPRESSION 4,000 PSI VALVE TYPE ASTM A-167 CARBON STEEL BALL VALVE 1,000 PSI FORGED STEEL BALL VALVE 4,000 PSI PIPE TYPE ASTM B88 TYPE "L" COPPER TUBING ASME B-16.22 WROUGHT COPPER & BRONZE 125 PSI NA ASME B-32 - SOLDER GRADE 95TA (LEAD FREE) 125 PSI ASTM A/ASME SA-269 STAINLESS STEEL TUBING 3/4" 1" 1-1/4" = = = 0.049 0.065 0.083 EQ ID # 12291 12321 18001 18002 18004 79921 DESCRIPTION DRUM CART DOLLY, WHEEL TOOLBOX TOOLBOX TOOLBOX, ROLLING TOTE, DEF EQUIPMENT LINE TYPE LEGEND CF/CI OF/CI OF/OI STAINLESS STEEL FITTINGS 1,000 PSI COMPRESSION 1,000 PSI STAINLESS STEEL BALL VALVE 1,000 PSI PIPING NOTES 2. INSTALLING CONTRACTOR SHALL INSTALL PIPING/TUBING IN ACCORDANCE WITH THE PLANS PROVIDED IN THESE CONSTRUCTION DOCUMENTS AND WITH THE APPLICABLE NFPA CODES AND REGULATIONS. 3. ALL PIPING/TUBING, JOINTS, UNIONS AND CONNECTIONS SHALL BE PAINTED. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL COORDINATE ALL ASPECTS OF THE PAINTING. ALL PIPING/TUBING SHALL BE PROPERLY PREPARED AND CLEANED PRIOR TO APPLYING ONE COAT OR PRIMER AND ONE COAT OF FINISH PAINT. PAINT COLOR AND TYPE SHALL BE COORDINATED WITH ARCHITECT. 4. INSTALLING CONTRACTOR SHALL PREPARE ALL PIPING/TUBING CONNECTIONS TO EQUIPMENT WITH THE NECESSARY FLANGES OR UNIONS AS REQUIRED AND ALLOW FOR PROPER CLEARANCE AND ACCESS TO JOINTS. FLANGES AND UNIONS SHALL BE PROVIDED BY THE INSTALLING CONTRACTOR FOR ALL CONNECTIONS. 5. INSTALLING CONTRACTOR SHALL ROUTE ALL PIPING/TUBING IN AN ORDERLY MANNER, AND IN THE LOCATION OR ZONE DESIGNATED ON THESE CONSTRUCTION DRAWINGS. PIPING/TUBING SHALL BE GROUPED WHENEVER PRACTICAL AT COMMON ELEVATIONS AND SHALL BE BENT WHEREVER A CHANGE IN DIRECTION IS NECESSARY. 90 DEGREE FITTINGS SHALL ONLY BE USED WHEN TUBING CANNOT BE BENT TO CHANGE DIRECTION DUE TO FIELD CONDITIONS OR OTHER PHYSICAL CONSTRAINTS. 6. INSTALLING CONTRACTOR SHALL INSTALL ALL PIPING/TUBING IN A MANNER THAT CONSERVES BUILDING AREA AND NOT INTERFERE WITH THE PRIMARY USE OF THE SPACE. PIPING/TUBING SHALL BE SPACED NO CLOSER THAN 4 INCHES TOGETHER AND NO MORE THAN 6 INCHES APART. 7. INSTALLING CONTRACTOR SHALL INSTALL ALL PIPING/TUBING IN A MANNER THAT WILL ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING THE PIPE, TUBE, JOINTS, UNIONS, OR CONNECTED EQUIPMENT. 9. INSTALLING CONTRACTOR SHALL LABEL ALL PRODUCT PIPING/TUBING WITH PRODUCT LABELS AND DIRECTION OF FLOW LABELS EVERY 20 FEET OR MORE OFTEN IF NEEDED FOR CLARITY. 10. PRODUCT PIPING SHALL BE TESTED PNEUMATICALLY AT 125 PSI AND HELD FOR 4 HOURS WHILE CHECKING FOR LEAKS. PIPING SHALL THEN BE TESTED WITH PRODUCT TO AVOID CONTAMINATION AT 150 PERCENT OF PUMP OPERATING PRESSURE (120 PSI). 12. ALL PIPING/TUBING SHALL BE INSTALLED BY AN EXPERIENCED INSTALLATION CONTRACTOR WITH A MINIMUM OF 5 YEARS EXPERIENCE INSTALLING PROCESS FLUID PIPING SYSTEMS FOR VEHICLE MAINTENANCE FACILITIES. INSTALLING CONTRACTOR SHALL PROVIDE AND MAINTAIN A WARRANTY FOR THE SYSTEMS AND ITS COMPONENTS FOR ONE FULL YEAR FROM ACCEPTANCE. 13. INSTALLING CONTRACTOR SHALL PROVIDE DETAILED SYSTEM AND COMPONENT SHOP DRAWINGS TO THE DESIGN TEAM FOR APPROVAL PRIOR TO INSTALLATION. 15. ALL SYSTEMS COMPONENTS (I.E. PUMPS, VALVES, REGULATORS, AND PRODUCT PIPING/TUBING) INSTALLED AS A PART OF THE CENTRAL LUBRICATION DISTRIBUTION SYSTEM AND WASTE OIL AND WASTE COOLANT RECOVERY SYSTEMS SHALL BE TESTED BY THE INSTALLING CONTRACTOR PRIOR TO ACCEPTANCE BY THE OWNER. PIPING/TUBING SHALL BE TESTED PNEUMATICALLY AT 125 PSI AND HELD FOR 4 HOURS WHILE CHECKING THE ENTIRE SYSTEM FOR LEAKS. PIPING/TUBING SHALL THEN BE TESTED WITH PRODUCT AT 150% OF PRODUCT PUMPS STANDARD OPERATING PRESSURE (120 PSI). CHECKED BY: Checker 16. INSTALLING CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING PRODUCT OUTPUT AT NOZZLES AND FOR PUMP INTAKE. INSTALLING CONTRACTOR IS RESPONSIBLE FOR CLEANING ALL DELIVERY KITS, NOZZLES, SCREENS, AND REMOVING DEBRIS AND OBSTRUCTIONS FROM THE SYSTEMS AND RETESTING THE ENTIRE SYSTEM AS NECESSARY. 17. INSTALLING CONTRACTOR SHALL CLEAN UP ANY OILS, GREASE, AND SOLVENT DRIPS OR LEAKS AND TOUCHUP ANY DAMAGE TO PAINTED FINISHES AND MAKE THE SYSTEM READY FOR USE. 3/29/2013 2:01:40 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt 14. INSTALLING CONTRACTOR SHALL REMOVE ALL SCALING, DIRT, CORROSION, AND DEBRIS FROM INSIDE AND OUTSIDE OF PIPING, FITTINGS, JOINTS, AND VALVES BEFORE ASSEMBLY. PRODUCT ABBREVIATIONS ASTM B32-SOLDER GRADE 95TA (LEAD FREE) AUTOMATIC TRANSMISSION FLUID (MD-3) CHASSIS GREASE DIESEL EXHAUST FLUID ENGINE COOLANT ENGINE OIL (15W40) ENGINE OIL (5W-30) ENGINE OIL (CNG) GEAR OIL (75W-90) HYDRAULIC OIL USED COOLANT USED OIL WINDSHEILD WASHER FLUID GENERAL NOTES VALVE TYPE ASTM B283-C37700 BRASS BALL VALVE 300 PSI (MIN) PROVIDE 3/8 INCH QUICK DISCONNECT COUPLERS AT EACH COMPRESSED AIR DROP GRACO MODEL #110198. PROVIDE 1/2 INCH QUICK DISCONNECT GRACO MODEL NUMBER 110199. VERIFY WITH OWNER THE TYPE OF COUPLER TO MATCH EXISTING TOOL CONNECTIONS. PROVIDE 3/4 INCH PORT SIZE FILTER / REGULATOR / LUBRICATOR ASSEMBLY AS SHOW ON DETAIL: X GRACO MODEL #217073 OR APPROVED EQUAL. FOR FILTER/REGULATOR ASSEMBLY AS SHOWN ON DETAIL X GRACO MODEL #'S 106150 AND 244845. PIPING NOTES 1. INSTALL VALVED BYPASS AROUND AIR DRYER. FACTORY INSULATE INLET AND OUTLET CONNECTIONS. 2. INSTALL PIPING IN ACCORDANCE WITH PLANS AND LOCAL CODES AND REGULATIONS. 1. INSTALLING CONTRACTOR SHALL ENSURE THAT ALL FITTINGS, JOINTS, AND VALVES FOR FLUID PIPING/TUBING SHALL MATCH THE PROPER RATING AND BURST PRESSURE OF THAT FLUID TYPE. 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t SPEC FURNISH SECTION INSTALL START OF/OI START OF/OI START OF/OI START OF/OI START OF/OI START OF/OI ATF CG DEF EC EO1 EO2 EO3 GO HO UC UO WWF FITTING TYPE JOINT TYPE ANSI B16.22 WROUGHT COPPER SOLDER JOINT SPEC FURNISH SECTION INSTALL 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI 11 11 40 OF/CI OF/OI EQUIPMENT SCHEDULE ASTM A-167 BRASS BALL VALVE 300 PSI FILTER / REGULATOR / LUBRICATOR ASSEMBLY DIESEL EXHAUST FLUID (DEF) JACK, AIR/HYDRAULIC JACK, AIR/HYDRAULIC JACK, SERVICE, FLOOR, 4 TONS JACK, SERVICE JACK, SERVICE, FLOOR, 12 TON JACK, STAND, LIFT, PORTABLE JACK, TRANSMISSION, PORTABLE JACK, TRANSMISSION, PORTABLE LIFT, SURFACE MOUNTED, TWO POSTS, 18,000 POUNDS LIFT, COLUMN, MOBILE (SET OF 4), 60,000 LBS. LIFT, COLUMN, MOBILE (SET OF 4), BATTERY OPERATED, 72,000 POUNDS. ENGINE HOIST TRANSMISSION HOIST PRESS, OIL FILTER, PNEUMATIC/AIR USED OIL TANK RECEIVER, USED OIL, 25 GALLONS UO BURNER SAFE/CASE, GUN, WALL MOUNTED ACCESSORIES QUICK COUPLERS ASTM B-88 TYPE "L" COPPER TUBING DESCRIPTION COMPRESSED AIR PIPING SCHEDULE LOW PRESSURE OILS FLUID (ATF, EO1, EO2, EO3, GO, UO) ENGINE COOLANT (EC) WINDSHIELD WASHER FLUID (WWF) USED COOLANT (WC) EQ ID # 54111 54112 54121 54123 54131 54141 54201 54202 57141 58401 58421 59001 59002 74911 79601 79991 92001 98011 3. INSTALLING CONTRACTOR SHALL PREPARE ALL PIPING/TUBING CONNECTIONS TO EQUIPMENT WITH THE NECESSARY FLANGES OR UNIONS AS REQUIRED AND ALLOW FOR PROPER CLEARANCE AND ACCESS TO JOINTS. FLANGES AND UNIONS SHALL BE PROVIDED BY THE INSTALLING CONTRACTOR FOR ALL CONNECTIONS. 4. INSTALLING CONTRACTOR SHALL ROUTE ALL PIPING/TUBING IN AN ORDERLY MANNER, AND IN THE LOCATION OR ZONE DESIGNATED ON THESE DRAWINGS. PIPING/TUBING SHALL BE GROUPED WHENEVER PRACTICAL AT COMMON ELEVATIONS AND SHALL BE BENT WHEREVER A CHANGE IN DIRECTION IS NECESSARY. 90 DEGREE FITTINGS SHALL BE USED ONLY WHEN TUBING CANNOT BE BENT TO CHANGE DIRECTION DUE TO FIELD CONDITIONS OR OTHER PHYSICAL CONSTRAINTS. 5. INSTALL CAPPED DRIP LEG SIX INCHES (6") LONG A THE BASE OF THE VERTICAL RISER AND AT THE ENDS OF MAIN PIPING RUNS WITH A VALVED DRAIN PIPE AT THE NEAREST FLOOR OR HUB DRAIN. 6. TEST PIPING WITH AIR AT 150 PSIG FOR A PERIOD OF AT LEAST ONE HOUR. THE PRESSURE READING SHALL NOT BE LESS THAN THE DIFFERENTIAL CAUSE BY TEMPERATURE. ALL LEAKING JOINTS SHALL BE REMADE WITH NEW MATERIALS. ALL EQUIPMENT SHALL BE DISCONNECTED PRIOR TO TEST. 7. ALL PIPING/TUBING SHALL BE INSTALLED BY AN EXPERIENCED INSTALLATION CONTRACTOR WITH A MINIMUM OF 5 YEARS EXPERIENCE INSTALLING PROCESS FLUID PIPING SYSTEMS FOR VEHICLE MAINTENANCE FACILITIES. INSTALLING CONTRACTOR SHALL PROVIDE AND MAINTAIN A WARRANTY FOR THE SYSTEM AND ITS COMPONENTS FOR ONE FULL YEAR FROM ACCEPTANCE. 1 ALL CONTRACTOR FURNISHED (CF) EQUIPMENT SHOWN ON THESE DRAWINGS WITH A FOUR DIGIT IDENTIFICATION NUMBER IS BASED ON A SPECIFIED MANUFACTURER. ANY MODIFICATION AND/OR SUBSTITUTION OF SAID EQUIPMENT IS SUBJECT TO COMPLETE COORDINATION BY THE CONTRACTOR OF ALL CONNECTIONS SERVICES, OPENING SIZE AND AN OTHER CONSTRUCTION RELATED REQUIREMENTS. 2 ALL EQUIPMENT SHOWN ON THESE DRAWINGS WITH A FIVE DIGIT IDENTIFICATION NUMBER IS AN EXISTING PIECE OF EQUIPMENT. CONTRACTOR TO INSTALL EXISTING EQUIPMENT LISTED AS OF/CI IN EQUIPMENT SCHEDULE. CONTRACTOR SHALL TEST OPERATION OF EXISTING EQUIPMENT WITH OWNER PRESENT PRIOR TO RELOCATION AND AFTER IT IS INSTALLED IN THE NEW FACILITY. EXISTING EQUIPMENT SHALL OPERATE IN THE SAME OR BETTER CONDITION AS PREVIOUSLY INSTALLED. COORDINATE SCHEDULE OF REMOVAL WITH OWNER. 3 CONTRACTOR TO VERIFY AND COORDINATE ALL STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING REQUIREMENTS OF EQUIPMENT WITH MANUFACTURER'S APPROVED SHOP DRAWINGS PRIOR TO INSTALLATION. 4 THIS LAYOUT IS PROVIDED FOR GENERAL LOCATION OF EQUIPMENT. UNLESS SPECIFICALLY LOCATED BY DIMENSIONS ON THE DRAWINGS, THE EQUIPMENT SHALL BE PLACED NEAR THE THE LOCATION ON THE DRAWINGS BU IN THE MOST OPERATIONALLY EFFICIENT POSITION AND ORIENTATION. 5 SEISMMICALLY BRACE ALL FIXED EQUIPMENT AND STORAGE EQUIPMENT PER LOCAL AND STATE SEISMIC RESTRAINT GUIDELINES. 6 CONTRACTOR SHALL REFER TO EQUIPMENT LAYOUT DRAWINGS FOR EXACT LOCATIONS AND COORDINATION OF ALL EQUIPMENT. REFERENCE EQ0.01 FOR EQUIPMENT IDENTIFIERS AND DESCRIPTION. 7 COORDINATE WORK WITH ARCHITECTURAL FEATURES SO THE INTERFERENCE BETWEEN PIPING, EQUIPMENT, MECHANICAL WORK AND BUILDING STRUCTURE IS AVOIDED. 8 REFER TO PIPING TABLES ON SHEET EQ0.01 FOR SYSTEM REQUIREMENTS, MATERIALS AND METHODS OF CONSTRUCTION. 9 NOT ALL PIPING OFFSETS AND TRANSITIONS REQUIRED TO INSTALL PIPING ARE SHOWN ON THIS DRAWING. FIELD MEASURE FOR EXACT REQUIREMENTS AND INSTALL ACCORDINGLY. 10 SEISMICALLY BRACE ALL PIPING SYSTEMS PER 1998 SMACNA SEISMIC RESTRAINT GUIDELINES. DESIGN DEVELOPMENT BOARD, PEG, TOOL CABINET, STORAGE, GAS CYLINDER, LARGE CABINET, STORAGE, SHOP RACK, BULK STORAGE RACK, PALLET, HIGH BAY RACK, SPOOL, WIRE RACK, TIRE, HEAVY DUTY, 2 TIER SHELVING UNIT, 18" TABLE, RECEIVING, STEEL TOP, 6' WORKBENCH, SEVERE USE, 6' BENCH, BATTERY CHARGER, BATTERY, MULTIPLE, WITH BUS BAR CAGE, INFLATION, TIRE COMPRESSOR, AIR, RECEIVER MOUNTED, 10 HP DUPLEX COMPRESSOR, AIR, RECEIVER MOUNTED, 25 HP DUPLEX DRYER, AIR, REFRIGERATED, 100 CFM DRYER, AIR, REFRIGERATED, 250 CFM FLOOR SCRUBBER, 28" PATH FLOOR SCRUBBER, RIDING VISE, COMBINATION, SWIVEL BASE, 5 INCHES FUME EXTRACTION ARM, WELDING REEL, VEHICLE EXHAUST, MOTOR OPERATED, 6" HOSE REEL, VEHICLE EXHAUST, MOTOR OPERATED, 4" HOSE WASHER, PARTS, AUTOMATIC, FRONT LOAD WASHER, TWO BRUSH, DRIVE THROUGH CRANE, BRIDGE, TOP RUNNING, 5 TON FORKLIFT, LPG, 4,000 POUNDS LIFT, AXLE, SCISSOR, ADJUSTABLE, 60,000 LBS. LIFT, SURFACE MOUNTED, TWO POST, 18,000 POUNDS LIFT, PARALLELOGRAM, 75,000 POUNDS, 30 FEET LIFT, COLUMN, MOBILE (SET OF 4), BATTERY, WIRELESS, 72,000 POUNDS LIFT, COLUMN, MOBILE (SET OF 6), BATTERY, WIRELESS, 108,000 POUNDS FLUID MANAGEMENT SYSTEM PUMP, AIR PISTON (CG), W/ HOIST PUMP, AIR PISTON, 10:1 RATIO PUMP, DIAPHRAGM, NON-MIXING 40 GPM (EC) PUMP, DIAPHRAGM, DEF PUMP, DIAPHRAGM, USED FLUID EVACUATION (UO) PUMP, DIAPHRAGM, USED FLUID EVACUATION (UC) REEL BANK (WWF) REEL BANK (DEF, EC, EO1) REEL BANK (DEF, EC, EO1, WWF) REEL BANK (ATF, CG, EC, EO1, EO2, GO, WWF) REEL BANK (ATF, CG, EC, EO1, EO2, GO, HO, WWF) REEL BANK (ATF, CG, DEF, GO, EC, EO1, EO2, GO, HO, WWF) TANK, POLYETHYLENE, 200 GALLONS TANK, DOUBLE WALL, CUBE, 120 GALLONS TANK, DOUBLE WALL, CUBE, 280 GALLONS TANK, DOUBLE WALL, CUBE, 500 GALLONS RECEIVER, USED COOLANT, 25 GALLONS RECEIVER, USED OIL, 25 GALLONS SWEEPER, RIDING SPEC FURNISH SECTION INSTALL 10 56 00 CF/CI 10 56 00 CF/CI 10 56 00 CF/CI 10 56 00 CF/CI CF/CI 10 56 00 CF/CI 10 56 00 CF/CI 10 56 00 CF/CI 10 56 00 CF/CI 45 39 00 CF/CI 45 39 00 CF/CI 11 11 29 CF/CI 11 11 29 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 29 CF/CI 11 11 29 CF/CI 11 11 29 CF/CI 11 24 19 CF/CI 11 24 19 CF/CI 11 24 19 CF/CI 11 11 29 CF/CI 11 11 26 CF/CI 41 22 00 CF/CI 41 22 00 CF/CI 14 45 00 CF/CI 14 45 00 CF/CI 14 45 00 CF/CI 14 45 00 CF/CI 14 45 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 00 CF/CI 11 11 29 CF/CI JACKSON, WYOMING DESCRIPTION OF/CI EQUIPMENT SCHEDULE 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f EQ ID # 1098 1145 1185 1455 1545 1570 1637 1688 1798 1860 2030 2045 2110 2161 2165 2228 2231 2340 2341 2832 3290 3460 3466 3784 3841 5050 5405 5691 5716 5775 5842 5861 7240 7510 7520 7531 7532 7540 7541 7710 7730 7740 7770 7780 7790 7832 7950 7960 7970 7998 7999 9890 OF/CI EQUIPMENT SCHEDULE TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY CF/CI EQUIPMENT SCHEDULE 8. INSTALLING CONTRACTOR SHALL PROVIDE DETAILED SYSTEM AND COMPONENT SHOP DRAWINGS TO THE DESIGN TEAM FOR APPROVAL PRIOR TO INSTALLATION. 9. INSTALLING CONTRACTOR SHALL REMOVE ALL SCALING, DIRT, CORROSION, AND DEBRIS FROM INSIDE AND OUTSIDE OF PIPING, FITTINGS, JOINTS, AND VALVES BEFORE ASSEMBLY. 10. INSTALLING CONTRACTOR SHALL INSTALL ALL PIPING/TUBING IN A MANNER THAT WILL ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING THE PIPE, TUBE, JOINTS, UNIONS, OR CONNECTED EQUIPMENT. 11. ALL PIPING/TUBING,JOINTS, UNIONS AND CONNECTIONS SHALL BE PAINTED. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL COORDINATE ALL ASPECTS OF THE PAINTING. ALL PIPING/TUBING SHALL BE PROPERLY PREPARED AND CLEANED PRIOR TO APPLYING ONE COAT OR PRIMER AND ONE COAT OF FINISH PAINT. PAINT COLOR AND TYPE SHALL BE COORDINATED WITH ARCHITECT. No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: 3123 DATE: 04/02/13 SCALE: EQUIPMENT SCHEDULE AND NOTES 18. INSTALL PRODUCT PIPING TO PROVIDE THE MAXIMUM POSSIBLE CLEAR HEIGHT UNDERNEATH. ALL PIPING MUST BE A MINIMUM OF SIX FEET (6'-0") FROM HEATING DEVICES. 19. WORKING PRESSURE OF OIL PIPING SYSTEMS AND EQUIPMENT HAS BEEN DESIGNED AT 1000 PSIG. THE WORKING PRESSURE OF GREASE PIPING SYSTEMS AND EQUIPMENT HAS BEEN DESIGNED FOR 4000 PSIG. 20. THE ENTIRE SYSTEM AND ITS COMPONENTS ITEMS OF EQUIPMENT SHALL OPERATE WITHOUT OBJECTIONABLE VIBRATION OR NOISE. EQ001 Q 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f P P.1 P M1 R1 M1 R2 R2 (2) R3 M2 M2 R3 (10) (10) (5) R4 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t (6) M3 R4 M3 (2) M4 R5 M4 R5 1 EQ114 M5 R6 M5 R6 R7 R7 R8 J.5 P.2 G H.5 M6 B1 Q R R9 T A1 A2 DW A3 A4 B 1 EQ113 A5 A6 B H.3 L.1 A7 D.5 E.5 F.9 G.1 B2 A8 L L.1 M N A S B3 A9 C D E F G H 1 EQ111 A10 B4 A11 A12 1 EQ111 DESIGN DEVELOPMENT K JACKSON, WYOMING J TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY H.3 B5 A13 A14 A15 B6 A16 C.1 No N.1 DATE PROJECT No: 3123 DATE: 08/18/11 SCALE: 1/16" = 1'-0" CHECKED BY: JMB OVERALL EQUIPMENT LAYOUT PLAN 3/29/2013 2:01:57 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt L.9 REVISION/SUBMISSION COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. LEVEL ONE OVERALL EQUIPMENT LAYOUT PLAN 1 1/16" = 1'-0" EQ101 P A B C D E F G H H.3 J K LL.1 M Q N P.5 S M1 R2 M1 M1 R1 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f P.1 P R2 R2 R3 R3 M2 M2 M2 R3 R4 R4 M3 R4 M3 M3 R5 R5 M4 M4 M4 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t R5 1 EQ144 M4.5 M5 R6 M5 R6 M5 R6 R7 R7 N.1R7 P.1P.2 R R8 R8 R8 H.5 M6 B1 J.5 P M6R9 M6 B1 P.2 Q R Q R9 T B 1 EQ142 B1 A1 A2 A1 A1 A2 A2 A3 A3 A4 A3 A5 A5 A6 B C D.5 E.5 H.3 H.5 F.9 L.1 K.9 J.5 C.1 E.5 B2 H.3 D E A7 A7 F.9 G.1 B2 A A7 L.9 D.5 A5 F G H J J K K L L L.1 A8 A8 M M B2 A8 N N S C D E F G A9 H A9 A10 B4 A10 B4 B4 1 EQ143 A10 A11 A11 A11 A12 A12 A12 1 EQ141 B5 DESIGN DEVELOPMENT A9 JACKSON, WYOMING B3 TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY B3 B3 B5 B5 A13 A13 A13 A14 A14 A15 A15 A14 A15 A15.2 A15.5 B6 B6 B6 A15.9 A16 A16 A16 C.1 L.9 E.5 F.9 H.5 N.1 J.5 P.1P.2 No R REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: 3123 DATE: 08/23/11 C.1 L.9 N.1 S SCALE: 1/16" = 1'-0" CHECKED BY: Checker OVERALL OVERHEAD EQUIPMENT LAYOUT 3/29/2013 2:02:25 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt D.5 A16.3 1 OVERALL OVERHEAD EQUIPMENT PLAN 1/16" = 1'-0" EQ104 EQUIPMENT SCHEDULE REFERENCE SHEET EQ001 FOR ALL EQUIPMENT DESCRIPTIONS. P.1 P.2 R F.9 REFERENCE SHEET EQ001 FOR ALL EQUIPMENT GENERAL NOTES H.5 J.5 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES K.9 COMM 165 LOBBY 160 8' - 0" L B2 LOST & FOUND A8 G H J K MOP SINK M 163 N 1185 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t B3 BUS PARKING A9 1 A10 B4 WASH EQUIP/ COMPRESSOR MOP SINK 1 EQ501 166 1185 BUS PARKING 2 A11 VEHICLE BYPASS 152 3841 WATER ENTRY 167 A12 ELEC EQUIP 168 BUS WASH 153 B5 BUS PARKING ELEC SWITCH GEAR 3 169 A14 A15 A15.2 A15.5 B6 A15.9 L.9 DESIGN DEVELOPMENT 1185 JACKSON, WYOMING A13 TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY MOP SINK A16 N.1 EQUIPMENT LAYOUT PLAN - BUS STORAGE AND WASH 1 1/8" = 1'-0" No REVISION/SUBMISSION DATE PROJECT No: 3123 DATE: 08/18/11 SCALE: 1/8" = 1'-0" CHECKED BY: Checker EQUIPMENT LAYOUT BUS STORAGE AND WASH 3/29/2013 2:53:21 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. EQ111 EQUIPMENT SCHEDULE A GENERAL NOTES C D E D.5 E.5 F F.9 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f REFERENCE SHEET EQ001 FOR ALL EQUIPMENT DESCRIPTIONS. G C.1 REFERENCE SHEET EQ001 FOR ALL EQUIPMENT GENERAL NOTES D.5 E.5 F.9 G.1 B2 B2 B2 A D E G F 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t MOP SINK B3 B3 1185 C B4 D E F G B4 B4 MOP SINK 1185 ? TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY MOP SINK 1185 B6 DESIGN DEVELOPMENT B5 B5 JACKSON, WYOMING B5 B6 B6 C.1 D.5 E.5 F.9 C.1 EQUIPMENT LAYOUT PLAN - BUS STORAGE 1 1/8" = 1'-0" REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: 3123 DATE: 08/18/11 SCALE: 1/8" = 1'-0" CHECKED BY: Checker EQUIPMENT LAYOUT BUS STORAGE 3/29/2013 2:53:28 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt No EQ112 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f EQUIPMENT SCHEDULE REFERENCE SHEET EQ001 FOR ALL EQUIPMENT DESCRIPTIONS. GENERAL NOTES REFERENCE SHEET EQ001 FOR ALL EQUIPMENT GENERAL NOTES 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t Q R G P P.1 P.2 37181 M6 B1 FARE ROOM DRUG TEST DIRECTOR 164 154 155 MARKETING A1 157 A2 VEHICLE DRIVE AISLE ELEVATOR OFFICE 136 E1 159 A3 B C H.3 ? L.1 A5 LOBBY 160 LOBBY F.9 H.5 J.5 K.9 A7 COMM 165 2341 9890 LOBBY 160 8' - 0" L B2 LOST & FOUND A8 A D C.1 1 EQUIPMENT LAYOUT - DRIVE AISLE 1/8" = 1'-0" E F G H J K MOP SINK M L.9 N N.1 163 S No REVISION/SUBMISSION DESIGN DEVELOPMENT E.5 JACKSON, WYOMING D.5 TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY 160 DATE PROJECT No: 3123 DATE: 08/18/11 SCALE: 1/8" = 1'-0" CHECKED BY: Checker EQUIPMENT LAYOUT DRIVE AISLE 3/29/2013 2:53:37 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. EQ113 EQUIPMENT SCHEDULE 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f REFERENCE SHEET EQ001 FOR ALL EQUIPMENT DESCRIPTIONS. GENERAL NOTES REFERENCE SHEET EQ001 FOR ALL EQUIPMENT GENERAL NOTES 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t 1 EQ502 1145 1145 M1 12201 1688 (4) REBUILD SHOP 101 20201 1798 1098 (2) BREAK ROOM 5405 14591 (11) 1459114591 (8) (16) 102 14591 (6) 14591 (4) 29141 29151 14251 4' - 0" 29401 3' - 0" 3' - 0" TOOL CRIB M2 18611 MEN 22051 103 110 26901 LIGHT REPAIR LIGHT REPAIR LIGHT REPAIR 3 2 1 20761 14513 (3) 12001 (2) 111 54121 WOMEN 5716 57141 11401 15701 74911 79601 2832 1570 18001 BATTERY STORAGE 18004 23441 12001 11402 113 104 98011 11081 (5) TOOLBOX STORAGE 2832 11071 112 PARTS STORAGE 18002 1860 LUBE/ COMPRESSOR 14541 14512 14511 14513 7999 7998 114 2045 2045 2030 1860 7540 7541 M3 14501 14503 14502 (3) 3784 21911 1860 26981 COMMON WORK AREA 105 11351 16882 16881 (4) 15601 MANUALS & COPY MAINTENANCE SUPERVISOR 106 115 20751 2832 22201 M4 1860 2832 1860 1860 2832 1637 2110 12321 TIRE SHOP PARTS ACCESS 25501 1637 24501 1860 23601 24401 49051 2832 117 1860 116 1637 1637 7998 PORTABLE EQUIP STORAGE 7541 79991 131 7540 HEAVY REPAIR 1860 8 M5 2832 HEAVY REPAIR 1860 7 2832 HEAVY REPAIR 1860 2832 HEAVY REPAIR 6 1860 5 2832 HEAVY REPAIR 1860 4 2832 HEAVY REPAIR 1860 2832 HEAVY REPAIR 3 7780 1860 2 M4.5 2832 HEAVY REPAIR 1860 CONTROLS 5775 1 7780 7780 35401 32751 54141 (4) 54201 26381 26401 2340 29201 59002 26391 5775 29351 29161 5775 5691 21061 21051 5861 54123 20401 (3) 54202 DESIGN DEVELOPMENT 1860 2832 JACKSON, WYOMING 2832 TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY 79991 (SET OF 6) 58401 (SET OF 4) 5691 CONTROLS & ADAPTER RACK 54131 59001 54131 (SET OF 4) 54111 5775 CONTROLS 54112 SOAP DRUM WASH EQUIP. 15' - 0" 5842 (SET OF 4) 58421 (SET OF 4) 58401 5691 CONTROLS & ADAPTER RACK CHASSIS WASH 133 G 132 37181 M6 B1 A B C D E F G H H.3 J K L L.1 M No REVISION/SUBMISSION DATE PROJECT No: 3123 CHECKED BY: Checker EQUIPMENT LAYOUT PLAN - VEHICLE MAINTENANCE 1 1/8" = 1'-0" 3/29/2013 2:53:55 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. DATE: 08/18/11 SCALE: 1/8" = 1'-0" EQUIPMENT LAYOUT VEHICLE MAINTENANCE EQ114 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 N 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f N EQUIPMENT SCHEDULE EQ ID # SPEC SECTION DESCRIPTION 2158 2228 COMPRESSOR, AIR, RECEIVER MOUNTED, 5 HP DUPLEX DRYER, AIR, REFRIGERATED, 100 CFM 11 11 00 11 11 00 FURNISH INSTALL CF/CI CF/CI M M GENERAL NOTES REFERENCE SHEETEQ100 FOR ALL EQUIPMENT GENERAL NOTES. L L K K 1 J J I I COMPRESSORS 1 ELECTRICAL/STORAGE H H 3 ? G G 2158 2228 1' - 0" F F Z COMPRESSOR ROOM 6 E E D D JACKSON, WY 2 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY OFFICE EQUIPMENT LAYOUT PLAN 1 1/4" = 1'-0" C C B B REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: Project Number DATE: 04/08/10 CHECKED BY: Checker SCALE: A A 4/8/2013 8:00:02 AM DRAWN BY: Author V:\PROJECTS\Jackson_WY_05Z034\Drawings\STARTBus_CNG_EQ_2013.rvt No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1/4" = 1'-0" EQUIPMENT LAYOUT PLAN CNG BUILDING EQ117 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 N 2 1 EQUIPMENT SCHEDULE 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f 3 N REFERENCE SHEET EQ001 FOR ALL EQUIPMENT DESCRIPTIONS. GENERAL NOTES M M REFERENCE SHEET EQ001 FOR ALL EQUIPMENT GENERAL NOTES A B C D E F G H H.3 J K L L.1 M L L M1 M1 M1 K K J J M2 M2 M2 I I M3 M3 M3 1455 (6) H M4 H M4 M4 G G F Unoccupied E E D D H.5 C M6 J.5 M6 M6 B1 B1 DESIGN DEVELOPMENT Unoccupied F JACKSON, WYOMING M5 M5 TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY M4.5 M5 C R9 B1 B B A B C D E F G H H.3 J K LL L.1 No M REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: 3123 DATE: 03/19/13 CHECKED BY: Checker MAINTENANCE MEZZANINE 1 1/8" = 1'-0" SCALE: A A 3/29/2013 2:54:09 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1/8" = 1'-0" MAINTENANCE MEZZANINE EQUIPMENT LAYOUT PLAN EQ124 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 N G H J H.5 F.9 J.5 H.5 K L J.5 M P.1 P.2 Q R S K.9 L.9 EQUIPMENT SCHEDULE M NN.1 M REFERENCE SHEET EQ001 FOR ALL EQUIPMENT DESCRIPTIONS. F.9 G.1 SERVICE EQUIPMENT PIPING ROUTING B2 7730 L 7730 H.3 B2 J K L L.1 A8 M N B2 A8 A8 GENERAL NOTES L 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f N G H J K M N L REFERENCE SHEET EQ001 FOR ALL EQUIPMENT GENERAL NOTES 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t SERVICE EQUIPMENT PIPING ROUTING S B3 B3 B3 A9 K G A9 H A9 J K J A10 A10 A10 B4 B4 7740 7740 I I A11 A11 A11 H H A12 A12 A12 G G A13 7740 A13 E F E A14 A14 A15 A15 A14 A15 A15.2 D D DESIGN DEVELOPMENT 7740 F JACKSON, WYOMING A13 TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY B5 B5 A15.5 7710 7710 B6 B6 A15.9 A16 A16 A16 C C L.9 F.9 B H.5 J.5 N.1 L.9 N.1 P.1 P.2 R S B OVERHEAD EQUIPMENT LAYOUT BUS STORAGE AND WASH AREA 1 1/8" = 1'-0" No REVISION/SUBMISSION DATE PROJECT No: 3123 DATE: 03/13/13 CHECKED BY: Checker SCALE: A A 3/29/2013 2:54:27 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1/8" = 1'-0" OVERHEAD EQUIPMENT LAYOUT BUS STORAGE AND WASH EQ141 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 N N D E F G H H.5 EQUIPMENT SCHEDULE M 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f C M A7 REFERENCE SHEET EQ001 FOR ALL EQUIPMENT DESCRIPTIONS. D.5 E.5 F.9 H.5 C.1 GENERAL NOTES D.5 E.5 7730 L G.1 L 7730 B2 REFERENCE SHEET EQ001 FOR ALL EQUIPMENT GENERAL NOTES F.9 H.3 B2 D E G F 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t B2 H K K B3 B3 C D E F G H J J I I B4 B4 H H G G F F B5 B5 B5 7740 7740 E E D D 7710 C B6 7710 DESIGN DEVELOPMENT 7740 JACKSON, WYOMING 7740 TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY B4 C B6 B6 C.1 B B No E.5 F.9 H.5 DATE PROJECT No: 3123 DATE: 03/13/13 C.1 CHECKED BY: Checker SCALE: OVERHEAD EQUIPMENT LAYOUT BUS STORAGE 1 1/8" = 1'-0" A 3/29/2013 2:55:09 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt D.5 REVISION/SUBMISSION COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 1 2 3 4 5 6 7 8 9 A 10 11 12 13 14 15 16 17 18 1/8" = 1'-0" OVERHEAD EQUIPMENT LAYOUT BUS STORAGE EQ142 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 N 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f 3 2 1 EQUIPMENT SCHEDULE N REFERENCE SHEET EQ001 FOR ALL EQUIPMENT DESCRIPTIONS. GENERAL NOTES M M REFERENCE SHEET EQ001 FOR ALL EQUIPMENT GENERAL NOTES L L K K A C D E F G H J K L M NN.1 P PP.1 P.2 P.5 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t Q R J J H.5 J.5 M6 M6 M6 B1 B1 P.2 R9 Q R R9 B1 T I I A1 A1 A1 A2 A2 A2 H H A3 A3 A4 A3 B G G L.1 A5 A5 A6 A5 F F A7 D.5 E.5 F.9 H.5 J.5 K.9 C.1 L.9 A7 A7 E E D.5 E.5 7730 F.9 G.1 7730 B2 L H.3 B2 J K L L.1 A8 M N B2 A8 A8 A D E G F H J K M N D D DESIGN DEVELOPMENT H.3 JACKSON, WYOMING C TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY B S CC.1 C.1 D D.5 E.5 E F.9 F G H H.5 J.5 L.9 L.9 N.1 P.1 P.2 R C C OVERHEAD EQUIPMENT LAYOUT DRIVE AISLE 1 1/8" = 1'-0" B B No REVISION/SUBMISSION DATE PROJECT No: 3123 DATE: 03/13/13 CHECKED BY: Checker SCALE: A A 3/29/2013 2:55:35 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1/8" = 1'-0" OVERHEAD EQUIPMENT LAYOUT DRIVE AISLE EQ143 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 N M M A B C D E F G H H.3 J K L L.1 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f 18 N M L L M1 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t M1 M1 FUME ARM TRAVEL K K 3290 M2 M2 M2 J J 3466 3466 I I 92001 M3 M3 M3 7770 7770 H H M4 M4 M4 SERVICE EQUIPMENT PIPING ROUTING M4.5 M5 G G M5 M5 7790 7780 3460 3460 7780 3460 F F 5050 E E D D 3460 BRIDGE CRANE RAIL 3460 3460 3460 H.5 M6 B1 DESIGN DEVELOPMENT 3460 JACKSON, WYOMING 7780 TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY BRIDGE CRANE RAIL 3460 J.5 M6 M6 B1 R9 B1 C C A B C D E F G H H.3 J K LL L.1 M OVERHEAD EQUIPMENT LAYOUT VEHICLE MAINTENANCE 1 1/8" = 1'-0" B B No REVISION/SUBMISSION DATE PROJECT No: 3123 DATE: 03/13/13 CHECKED BY: Checker SCALE: A A 3/29/2013 2:55:50 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1/8" = 1'-0" OVERHEAD EQUIPMENT LAYOUT VEHICLE MAINTENANCE EQ144 EQUIPMENT SCHEDULE REFERENCE SHEET EQ001 FOR ALL EQUIPMENT DESCRIPTIONS. GENERAL NOTES REFERENCE SHEET EQ001 FOR ALL EQUIPMENT GENERAL NOTES EQ ID # 1 2 3 4 5 6 7 8 9 10 11 12 15 16 17 18 19 20 21 22 23 WASH EQUIPMENT SCHEDULE DESCRIPTION MAIN CONTROL PANEL RECYCLING / PUMP CONTROL PANEL FINAL RINSE BOOSTER PUMP WITH BUFFER TANK CHEMICAL INJECTION PUMP (RINSE AID) CHEMICAL INJECTION PUMP (DETERGENT) DETERGENT METERING SYSTEM HIGH PRESSURE PUMP BUFFER TANK FOR RECYCLE OR HIGH PRESSURE PUMP WASH WATER PUMP WATER RECYLCING SYSTEM WATER SOFTNER SUBMERSIBLE PUMP TIRE GUIDE WHEEL WASH UNDERCHASSIS WASH PRE SOAK ARCH HIGH PRESSURE ARCH TWO BRUSH SYSTEM TRAFFIC LIGHT HIGH PRESSURE PUMP - 2 OZONE GENERATOR N N.1 P.1 P.2 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f L.9 7531 79921 DEF 7520 B3 B3 7531 7960 ATF 7832 WWF 21 15 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t A9 BUS WASH 7531 153 7520 7960 EC A9 A9 7960 EO1 PIT #1 2 23 PIT #2 1 12 WASH EQUIP/ COMPRESSOR 10 165 FLOOR DRAIN A10 8 8 A10 A10 22 7 9 B4 6 11 5 4 3 HOUSEKEEPING PAD A11 3841 2161 20 19 WATER ENTRY 167 21 A12 A12 16 A12 DESIGN DEVELOPMENT A11 JACKSON, WYOMING 2228 TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY A11 17 ELEC EQUIP 168 18 B5 A13 No REVISION/SUBMISSION DATE A13 A13 PROJECT No: 3123 DATE: 08/18/11 SCALE: 1/4" = 1'-0" CHECKED BY: Checker EQUIPMENT DETAILS & ENLARGED PLANS 3/29/2013 2:56:32 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. L.9 L.9 1 ENLARGED WASH AREAS 1/4" = 1'-0" N.1 N.1 P.1 P.2 EQ501 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 N M M L L K K J J I I L 1050 17th STREET, SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f 18 N 1600 STOUT STREET SUITE 940 DENVER, CO 80202 300 302 0266 t L.1 H H M1 M1 G 7520 7960 (ATF) 7532 G 79921 (DEF) F F 7832 (WWF) 7531 7520 7960 (HO) 7531 7520 7960 (EC) 7960 (EO2) E E 7510 (CG) M2 7240 M2 12291 7520 7950 (GO) HOUSEKEEPING PAD D 2231 D 2165 C C L B 1 L.1 B ENLARGED LUBE/COMPRESSOR ROOM 1/4" = 1'-0" No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: 3123 DATE: 03/05/13 CHECKED BY: Checker SCALE: A A 3/29/2013 2:56:41 PM DRAWN BY: Author C:\Users\bondjm\Documents\JAMES\Projects\Denver\Jackson_WY\EQPM START 2013.rvt DESIGN DEVELOPMENT 7970 (EO1) JACKSON, WYOMING 7960 (UC) TOWN OF JACKSON START BUS MAINTENANE & OPERATIONS FACILITLY 7520 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1/4" = 1'-0" EQUIPMENT DETAILS AND ENLARGED PLANS EQ502 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com F.9 H.5 K.9 J.5 N P P.2 R Job #: 755.011 High Performance Building Consultants B2 A8 LOST & FOUND 163 6" SAN 4" SAN 4" BUILDING DRAIN, RE: CIVIL DRAWINGS FOR CONTINUATION. I.E.=±96'-10" 6" GO B3 A9 6" GO 6" GO 6" GO A10 6" RDL 6" STORM, RE: CIVIL DRAWINGS FOR CONTINUATION (_____ SF) I.E.=+97'-0" 4"SAN B4 4"GO 4"GO WASH EQUIP/ COMPRESSOR 166 4"GO A11 6" F TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 3" CW A12 ELEC EQUIP 168 B5 A13 ELEC SWITCH GEAR 169 6" GO 6" GO 6" GO DESIGN DEVELOPMENT 6" GO 3" DOMESTIC WATER REDUCED PRESSURE BACKFLOW PREVENTER JACKSON, WYOMING 4" SA N FINISHED FLOOR ELEVATION = 100.-0" WATER ENTRY 167 SOG-1 2" V 4" GO STAIR 2 S2 6" SAN B6 NOT FOR CONSTRUCTION A15 2" V 4" GO 4" GO (2) 2" V RISE A14 2000 GALLON SAND/OIL INTERCEPTOR, SEE DETAIL 6" STORM, RE: CIVIL DRAWINGS FOR CONTINUATION I.E.=±98'-0" F E A16 6" SAN CHECKED BY: Checker H.3 F.9 4/1/2013 10:17:29 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt 6" SAN, RE: CIVIL DRAWINGS FOR CONTINUATION I.E.=±93'-10" 1 J K BUS PARKING LEVEL 0 - AREA A - PLUMBING PLAN SCALE: 1/8" = 1'-0" L L.1 M N D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: B A 3123 UNDERFLOORPLUMBING PLAN AREA A P-101 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants C D.5 E.5 F.9 B3 4" GO 6" GO PIPING UPSTREAM OF CLEANOUT TO BE COMPLETED DURING PHASE II I.E.=±97'-4" 4" GO DESIGN DEVELOPMENT B5 JACKSON, WYOMING B4 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY PIPING UPSTREAM OF CLEANOUT TO BE COMPLETED DURING PHASE II I.E.=±97'-4" 6" GO NOT FOR CONSTRUCTION F E B6 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B CC.1 4/1/2013 10:17:30 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 D E UNDERFLOOR-PLUMBING PLAN-AREA B SCALE: 1/8" = 1'-0" F A 3123 UNDERFLOOR PLUMBING PLAN AREA B P-102 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants J H.5 K J.5 L M N R B1 DRUG TEST 154 DIRECTOR 155 2" PUMP DISCHARGE RISE DW A2 4"SAN A2 ESP-1 OFFICE 159 A3 A3 4"GO 4" SAN 4"GO 4"GO A5 6" GO A5 6" GO 3"SAN A1 DESIGN DEVELOPMENT A1 MARKETING 157 JACKSON, WYOMING BREAK/ COPY 156 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 3" SAN 6" GO LOBBY 160 NOT FOR CONSTRUCTION A7 4" SAN A7 VESTIBULE 161 & LOST FOUND 163 VESTIBULE 162 F H.3 J K L.1 M N D P.2 CHECKED BY: Checker 1 DRIVE AISLE LEVEL 0 - AREA C - PLUMBING PLAN SCALE: 1/8" = 1'-0" C Q 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: B 4/1/2013 10:17:32 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt H E A 3123 UNDERFLOOR PLUMBING PLAN AREA C P-103 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants D.5 G E.5 H A3 4"GO 4"GO A5 4" GO 6" GO DESIGN DEVELOPMENT A2 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY B1 A7 NOT FOR CONSTRUCTION B2 F A B C D D.5 E E.5 F F.9 E H D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 10:17:33 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: DRIVE AISLE LEVEL 0 - AREA D - PLUMBING PLAN SCALE: 1/8" = 1'-0" B A 3123 UNDERFLOOR PLUMBING PLAN AREA D P-104 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H J H.5 J.5 K L P M P.1 P.2 Q R R2 M1 R3 M2 M2 6" STORM, RE: CIVIL DRAWINGS FOR CONTINUATION I.E.=±97'-0" R4 M3 M3 R5 M4 R6 M5 6" SAN 2" V 6" SAN 6" GO 6" SAN 6" BUILDING DRAIN, RE: CIVIL DRAWINGS FOR CONTINUATION I.E.=±94'-2" 2000 GALLON SAND/OIL INTERCEPTER, SEE DETAIL SOG-2 R7 DESIGN DEVELOPMENT 2" V 4" SAN JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY (2) 2" V RISE 6" GO I.E=±95'-0" NOT FOR CONSTRUCTION R8 6" GO 6" GO FINISHED FLOOR ELEVATION = 100'-0" GAS SERVICE BY LOCAL GAS COMPANY ESP-2 M6 M6 B1 B1 F E B1 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: H.3 J K L L.1 L.9 N.1 P.2 R S CHECKED BY: Checker B 4/1/2013 10:17:34 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt H 1 MAINTENANCE LEVEL 0 - AREA E - PLUMBING PLAN SCALE: 1/8" = 1'-0" A 3123 UNDERFLOOR PLUMBING PLAN AREA E P-105 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A B D D.5 E E.5 F G H M1 M2 4" SAN M3 2" DRAIN FROM PARTS WASH M4 DESIGN DEVELOPMENT M5 JACKSON, WYOMING 6" GO TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 4" SAN NOT FOR CONSTRUCTION 6" GO M6 B1 F A B CC.1 D E F G H D E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 10:17:36 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: MAINTENANCE LEVEL 0 - AREA F - PLUMBING PLAN SCALE: 1/8" = 1'-0" B A 3123 UNDERFLOOR PLUMBING PLAN AREA F P-106 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com N F.9 H.5 L J.5 P P.2 Job #: 755.011 R M High Performance Building Consultants LOST & FOUND 163 B2 EXTEND DRAINS FROM SERVICE SINKS INTO TRENCH DRAIN. 3/4" HWC 3/4" HW 3" CW WH-1 4"FCO TD-1 SERVICE SINK A8 B3 4"GCO, TWO-WAY A9 HW AND CW UP TO 2ND FLOOR ADMIN 1 1/2" CW PROVIDE EMERGENCY SHOWER EYEWASH STATION W/ THERMOSTATIC MIXING VALVE. 3/4" HW WH-1 TD-1 3" CW TD-1 B4 ESEW-1 ESEW-1 DOWN SPOUT NOZZEL LOCATED AT 2 ' BELOW ROOF LEVEL. COOR. W/ ELECTRICAL FOR HEAT TRACE. 4"FS-1 HB-1 A10 DPB-2 2" CW MAKE-UP TO WASH EQUIPMENT EXTEND DRAINS FROM SERVICE SINKS INTO TRENCH DRAIN. 3" CW A11 WATER ENTRY 167 6"FS-1 6" FROM OVERFLOW DRAIN IN WASH EQUIP. ROOM INTO WASH BAY TRENCH. WH-1 A12 ELEC EQUIP 168 EXTEND DRAINS FROM SERVICE SINKS INTO TRENCH DRAIN. SERVICE SINK B5 A13 DESIGN DEVELOPMENT 1 P-401 JACKSON, WYOMING SERVICE SINK TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY TD-1 6" FROM WASH BAY TRENCH TO WATER RECLAIM PIT. ELEC SWITCH GEAR 169 NOT FOR CONSTRUCTION A14 SOG-1 (2) 2"V COMBINE AT 3'-0" A.F.F, 3"V UP TO 3" VTR A15 STAIR 2 S2 4"GCO 6"RDL RISE ON WALL, DN BELOW SLAB. TD-1 TD-1 F DOWN SPOUT NOZZEL LOCATED AT 2 ' BELOW ROOF LEVEL. COOR. W/ ELECTRICAL FOR HEAT TRACE. TD-1 B6 A16 D CHECKED BY: Checker 4/1/2013 10:17:38 AM D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt DRAWN BY: Author H.3 J J.5 BUS PARKING LEVEL 1 - AREA A - PLUMBING PLAN SCALE: 1/8" = 1'-0" K K.9 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: B F.9 C 4"GCO WH-1 1 E M N.1 P A 3123 LEVEL 1 - PLUMBING PLAN - AREA A P.2 P-111 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants D.5 E.5 F.9 B3 TD-1 TD-1 TD-1 4"FCO 4"FCO 4"FCO DESIGN DEVELOPMENT B5 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY B4 4"FCO NOT FOR CONSTRUCTION F TD-1 TD-1 E TD-1 B6 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B C 4/1/2013 10:17:39 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 D E LEVEL 1 - PLUMBING PLAN - AREA B F BUS PARKING LEVEL 1 - AREA B - PLUMBING PLAN SCALE: 1/8" = 1'-0" A 3123 P-112 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H H.5 J J.5 K L M N R 3" SAN 2-1/2" GAS UP TO MEZZANINE. B1 1 1/2"CW 1 1/2"HW 1 1/2"HWC WC-2 DRUG TEST 154 3"WCO DIRECTOR 155 MARKETING 157 A1 A2 4"WCO DW 4" SAN 2" ELEVATOR SUMP PUMP DISCHARGE UP FROM BELOW, TRANSITION TO 3" AT HORIZONTAL 3" ELEVATOR SUMP PUMP DISCHARGE SLOPED AT 1.04% OFFICE 159 A3 3" PUMP DISCHARGE AIR GAP TO TRENCH DRAIN TD-1 TD-1 4"FCO A5 3"WCO DESIGN DEVELOPMENT BREAK/ COPY 156 JACKSON, WYOMING WH-1 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY L-1 LOBBY 160 3" SAN 3"SAN NOT FOR CONSTRUCTION A7 3"SAN VESTIBULE 161 LOST & FOUND 163 3"CW 3/4"HW 3/4"HWC 1 1/2"CW VESTIBULE 162 F D H.5 J K L M N.1 P.2 R CHECKED BY: Checker 1 C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: S B 4/1/2013 10:17:41 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt H E A 3123 LEVEL 1 - PLUMBING PLAN - AREA C DRIVE AISLE LEVEL 1 - AREA C - PLUMBING PLAN SCALE: 1/8" = 1'-0" P-113 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A C D E F G H B1 A3 TD-1 TD-1 A5 TD-1 4"FCO DESIGN DEVELOPMENT A2 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY WH-1 NOT FOR CONSTRUCTION A7 1" CW 1" CW B2 1"CW F E WH-1 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: C D.5 E.5 F.9 H CHECKED BY: Checker B 4/1/2013 10:17:42 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt A 1 A 3123 LEVEL 1 - PLUMBING PLAN - AREA D DRIVE AISLE LEVEL 1 - AREA D - PLUMBING PLAN SCALE: 1/8" = 1'-0" P-114 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H.5 J.5 P P.1 P.2 Q R R2 M1 R3 ESEW-1; PROVIDE WITH THERMOSTATIC MIXING VALVE. M2 HB-1 1"CW MAKE-UP FOR ____ 4"FCO DSN-1 DOWN SPOUT LOCATED AT 2' BELOW ROOF. DBP-3 R4 6"RDL DROP 6" ODL 6" RDL WH-1 M3 R5 4"FCO WH-1 R6 M5 4"FCO 4"GCO, TWO-WAY WH-1 R7 PROVIDE 3/4" CW TO PRESSURE WASHER AND 1-1/2" GAS. GAS METER, REGULATION, VALVES, ETC. BY LOCAL GAS COMPANY. 2 LBS SUPPLY TO BUILDING R8 DESIGN DEVELOPMENT TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY COMBINE (2) 2"V AT 3'-0" A.F.F., 3"V RISE TO 3" VENT THRU ROOF WH-1 JACKSON, WYOMING M4 NOT FOR CONSTRUCTION 4"FCO ESEW-1 G DBP-2 M6 B1 F D H.3 J J.5 K L L.1 M N.1 P P.2 R CHECKED BY: Checker 1 MAINTENANCE LEVEL 1 - AREA E - PLUMBING PLAN C S 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: B 4/1/2013 10:17:44 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt H E A 3123 LEVEL 1 - PLUMBING PLAN - AREA E SCALE: 1/8" = 1'-0" P-115 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A B C D E F E.5 G H M1 IMB-1 IMB-1 S-2 W/ GDU-1 3/4" HWC 1 1/2" CW L-2 1 1/2" HW M2 L-2 WC-2 U-2 EWC-1 4"FCO HB-1 WC-2 WC-1 3/4" CW PROVIDE EMERGENCY SHOWER EYEWASH STATION WITH ACCESSIBLE THERMOSTATIC MIXING VALVE. 3/4" CW 1 1/4" CW 1 1/4" HW L-2 3/4"HWC 1 1/2"HW L-2 6" ODL ESEW-1 6" RDL 1 1/2"CW WH-1 M3 3/4" CW PROVIDE 2" DRAIN AND 3/4" FOR PARTS WASHER. M4 M5 DESIGN DEVELOPMENT 4"FCO JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY HB-1 NOT FOR CONSTRUCTION 4"FCO M6 B1 F D B C D E F G CHECKED BY: Checker 1 MAINTENANCE LEVEL 1 - AREA F - PLUMBING PLAN C H 1 DESIGN DEVELOPMENT No REVISION/SUBMISSION A 4/8/13 DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: B 4/4/2013 11:14:37 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_jim.thomas.rvt A E 3123 LEVEL 1 - PLUMBING PLAN - AREA F SCALE: 1/8" = 1'-0" P-116 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants 1 2" V UP. 3" SAN. UP 3" SAN 3" SAN 3" SAN. 2" V UP. 3" SAN. UP SCALE: 1/8" = 1'-0" 1 ELECTRICAL/STORAGE 3 DESIGN DEVELOPMENT CNG UNDERFLOOR - PLUMBING PLAN JACKSON, WYOMING 2 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 4" SAN Z NOT FOR CONSTRUCTION COMPRESSORS 1 3" FD-1 3" VTR 3" FD-1 OFFICE 2 Z 2" V 2" V 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 10:17:48 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: CNG LEVEL 1 - PLUMBING PLAN 3123 LEVEL 1 - PLUMBING PLAN - CNG BUILDING SCALE: 1/8" = 1'-0" P-117 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n F.9 H.5 J K.9 K J.5 L.9 N P 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: R www.megroup.com Job #: 755.011 N.1 B2 High Performance Building Consultants A8 B3 1" CW A9 A10 B4 1" CW 6"RDL & 6" ODL RISE TO DRAIN ABOVE B5 A13 DESIGN DEVELOPMENT A12 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY A11 A14 3"V UP TO 3" VTR A15 NOT FOR CONSTRUCTION 6"RDL & 6" ODL RISE TO DRAIN ABOVE 6" RDL 6" RDL 6" ODL 6" ODL B6 A16 F H.3 F.9 J K L L.1 L.9 N N.1 P R D E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B 4/1/2013 10:17:50 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 BUS PARKING LEVEL 2 - AREA A - PLUMBING PLAN SCALE: 1/8" = 1'-0" A 3123 LEVEL 2 - PLUMBING PLAN - AREA A P-121 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: F: 303 . 382 . 1930 C D E D.5 F E.5 www.megroup.com F.9 Job #: 755.011 High Performance Building Consultants B3 6" ODL 6" RDL B4 DESIGN DEVELOPMENT B5 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 6"RDL & 6" ODL RISE TO DRAIN ABOVE NOT FOR CONSTRUCTION 6"RDL & 6" ODL RISE TO DRAIN ABOVE 6" RDL 6" ODL B6 F D CHECKED BY: Checker 1 4/1/2013 10:17:52 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt C D D.5 E E.5 F BUS PARKING LEVEL 2 - AREA B - PLUMBING PLAN E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: F.9 B A 3123 LEVEL 2 - PLUMBING PLAN - AREA B SCALE: 1/8" = 1'-0" P-122 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: F: 303 . 382 . 1930 www.megroup.com Job #: 755.011 High Performance Building Consultants H H.5 J J.5 K B1 L M N Q R 1 1/2"HW 2"CW 3/4"HWC 3 P-401 A1 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 2 P-401 ? ? A2 A2 LOCKERS 204 A3 A3 MECHANICAL MEZZANINE 201 A5 A5 A1 DESIGN DEVELOPMENT WOMEN 202 JACKSON, WYOMING MEN 201 NOT FOR CONSTRUCTION A7 A7 F H.3 J J.5 K L L.1 L.9 M N D CHECKED BY: Checker 1 DRIVE AISLE LEVEL 2 - AREA C - PLUMBING PLAN C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: B 4/1/2013 10:17:54 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt H E A 3123 LEVEL 2 - PLUMBING PLAN - AREA C SCALE: 1/8" = 1'-0" P-123 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: F: 303 . 382 . 1930 www.megroup.com Job #: 755.011 High Performance Building Consultants A B C D E D.5 E.5 F G H B1 B1 A2 A2 A3 A3 A5 A5 A7 A7 6" OD-1 ABOVE NOT FOR CONSTRUCTION 6" RD-1 ABOVE B2 B2 F A E B C.1 D D.5 E E.5 F F.9 H D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 4/1/2013 10:17:55 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 DESIGN DEVELOPMENT A1 JACKSON, WYOMING A1 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 3/4" CW DN. TO WH-1. DRIVE AISLE LEVEL 2 - AREA D - PLUMBING PLAN B A 3123 LEVEL 2 - PLUMBING PLAN - AREA D SCALE: 1/8" = 1'-0" P-124 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H.3 P J K L.1 M N Q R2 P Q S R2 M1 R3 R3 S-1A W/ GDU-1 S-1A W/ GDU-1 M2 IMB-1 IMB-1 L-1A L-1A WC-1A WC-1A WC-1A WC-1A L-1A BT-1 L-1A BT-1 R4 R4 BT-1 BT-1 L-1A WC-1A L-1A WC-1A WC-1A WC-1A L-1A L-1A M3 1 1/2" CW IMB-1 IMB-1 1 1/2" HW 3/4" HWC S-1A W/ GDU-1 S-1A W/ GDU-1 R5 R5 R6 WC-1A R7 S-1A W/ GDU-1 1 1/2" HW R7 2" CW 3/4" HWC M5 L-1A BT-1 DESIGN DEVELOPMENT R6 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 3"V RISE TO 3" VENT THRU ROOF JACKSON, WYOMING M4 IMB-1 L-1A BT-1 WC-1A L-1A WC-1A WC-1A BT-1 R8 M6 M6 B1 B1 L-1A NOT FOR CONSTRUCTION R8 2"CW M6 F E B1 D C 1 DESIGN DEVELOPMENT No REVISION/SUBMISSION Q S H H.3 J K L M N.1 P Q S CHECKED BY: Checker B 4/3/2013 3:01:15 PM D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt DRAWN BY: Author P 1 MAINTENANCE LEVEL 2 - AREA E - PLUMBING PLAN SCALE: 1/8" = 1'-0" A DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: N 4/8/13 3123 LEVEL 2 - PLUMBING PLAN - AREA E P-125 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A B C D D.5 E E.5 F G H M1 M2 M3 1 1/2" CW 1 1/2" HW 3/4" HWC DESIGN DEVELOPMENT M5 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY M4 NOT FOR CONSTRUCTION M6 B1 F A B C D E F G H D E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 10:17:59 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: MAINTENANCE LEVEL 2 - AREA F - PLUMBING PLAN B A 3123 LEVEL 2 - PLUMBING PLAN - AREA F SCALE: 1/8" = 1'-0" P-126 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n P Q 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: R www.megroup.com Job #: 755.011 High Performance Building Consultants F.9 H.5 J J.5 K K.9 L.1 L.9 M B3 A9 A10 6" OD-1 B4 B5 A13 DESIGN DEVELOPMENT A12 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY A11 A14 A15 NOT FOR CONSTRUCTION 6" OD-1 B6 A16 F D CHECKED BY: Checker H.3 J K L L.1 L.9 M N N.1 4/1/2013 10:18:01 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt F.9 1 P Q E C R 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: B A 3123 ROOF - PLUMBING PLAN - AREA A BUS PARKING ROOF - AREA A - PLUMBING PLAN SCALE: 1/8" = 1'-0" P-131 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 C D D.5 E E.5 F F.9 High Performance Building Consultants 6" RD-1 6" OD-1 B3 6" OD-1 DESIGN DEVELOPMENT B5 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY B4 NOT FOR CONSTRUCTION F E 6" OD-1 B6 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 4/1/2013 10:18:02 AM CHECKED BY: Checker C DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 D D.5 E E.5 F BUS PARKING ROOF - AREA B - PLUMBING PLAN SCALE: 1/8" = 1'-0" F.9 B A 3123 ROOF - PLUMBING PLAN - AREA B P-132 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H H.5 J J.5 K L L.1 L.9 N.1 M P R B1 A2 A2 A3 A3 SOLAR PANELS FOR DOMESTIC WATER HEATER PRE-HEAT. A5 A5 DESIGN DEVELOPMENT TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY A1 JACKSON, WYOMING A1 A7 A7 NOT FOR CONSTRUCTION 6" OD-1 F H H.3 J K L L.1 L.9 M N N.1 R E S D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 10:18:05 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: DRIVE AISLE ROOF - AREA C - PLUMBING PLAN SCALE: 1/8" = 1'-0" B A 3123 ROOF - PLUMBING PLAN - AREA C P-133 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A B C D D.5 E E.5 F F.9 G H A3 A5 DESIGN DEVELOPMENT A2 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY B1 NOT FOR CONSTRUCTION A7 6" RD-1 6" OD-1 B2 F A B D D E E.5 F F.9 G CHECKED BY: Checker 1 DRIVE AISLE ROOF - AREA D - PLUMBING PLAN C H 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: B 4/1/2013 10:18:06 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt C E A 3123 ROOF - PLUMBING PLAN - AREA D SCALE: 1/8" = 1'-0" P-134 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H.5 J J.5 K L.1 M P Q R2 M1 R3 M2 R4 6" RD-1 6" OD-1 M3 R5 R6 M5 R7 DESIGN DEVELOPMENT TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 3" VTR JACKSON, WYOMING M4 NOT FOR CONSTRUCTION R8 F M6 E B1 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. H H.3 J J.5 K L.1 L.9 M NN.1 P S CHECKED BY: Checker B 4/1/2013 10:18:08 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 2 A 3123 ROOF - PLUMBING PLAN - AREA E MAINTENANCE ROOF - AREA E - PLUMBING PLAN SCALE: 1/8" = 1'-0" P-135 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A B C.1 D D.5 E E.5 F F.9 H M1 M2 6" RD-1 6" RD-1 6" OD-1 6" OD-1 M3 DESIGN DEVELOPMENT M5 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY M4 NOT FOR CONSTRUCTION F E M6 B1 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker A 4/1/2013 10:18:10 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 B C.1 D D.5 MAINTENANCE ROOF - AREA F - PLUMBING PLAN SCALE: 1/8" = 1'-0" E E.5 F F.9 H B A 3123 ROOF - PLUMBING PLAN - AREA F P-136 P.1 P.2 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f P B1 2" CW 3" CW 1 1/2" HW 1 1/2" HW 3/4" HWC 3/4" HWC 3" CW 2" GAS DN. WATER ENTRY 167 FPB-1 REFER TO FPC SHOP DRAWINGS FOR SIZING AND LAYOUT OF FIRE SPRINKLER ZONES 6"FS-1 2" G DPB-1 3/4" CW PROVIDE BALANCING VALVES SET AT 1 GPM. m GR UP e d e s i g n 2" CW 2" V 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: N.1 A1 1 www.megroup.com ENLARGED SCALE PLUMBING PLAN Job #: 755.011 SCALE: 1/4" = 1'-0" High Performance Building Consultants A2 DBP-4 2" G 4"FS-1 ERV-1 P P.1 P.2 Q R 3" CW 1" MAKE-UP WATER FOR ERV UNIT 3/4" HW 3/4" HWC A3 B1 WC-2 2" V WC-2 MSB-1 JAN 203 MECHANICAL MEZZANINE 201 3" G L-2 PROVIDE GAS SOLENOID VALVE FOR EMERGENCY SHUT OFF. PROVIDE SHUT OFF BUTTONS AT EA. EXIT FROM ROOM WC-1 WC-1 L-2 L-2 FD WH-1 U-1 TMV-1 & DPC-1 ON WALL FD WC-1 A5 TEA-1 L-2 L-2 U-2 2" CW 3"FS-1 WC-1 SOLAR CONTROL PANEL AND PUMP ON WALL WH-2 MEN 201 WOMEN 202 A1 1" GAS DN TO WATER HEATER. PROVIDE GAS PRESSURE REGULATING VALVE. 2 LBS TO 7" W.C.. (TYP. 2 WATER HEATERS) HWP-1 B-1 HWP-2 3 3"FS-1 AHU-1 2" V A7 B-3 K.9 3"FS-1 2" MAKE-UP WATER HYDRONIC SYSTEM HWP-3 ENLARGED SCALE PLUMBING PLAN SCALE: 1/4" = 1'-0" DESIGN DEVELOPMENT B-2 JACKSON, WYOMING 2" V N N.1 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 3" GAS DN TO BOILER. PROVIDE GAS PRESSURE REGULATING VALVE. 2 LBS TO 7" W.C.. (TYP. 3 BOILERS) 3"FS-1 B2 NOT FOR CONSTRUCTION L L.1 L.9 2 M N N.1 ENLARGED SCALE PLUMBING PLAN SCALE: 1/4" = 1'-0" 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker ENLARGED PLUMBING PLANS 4/1/2013 10:18:13 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: P-401 1-1/2"CW 1-1/2" CW REFER TO HVAC DRAWINGS FOR VENT AND COMBUSTION AIR SIZING 4" HDPE PIPE (TYP.) DOMESTIC HOT WATER CIRCULATION PUMP, DCP-1 GAS WATER HEATER GWH-2 3/4" HWC GAS COCK, TYPICAL HOSE END DRAIN VALVE, TYPICAL NEW SECTION OF PIPE SAME SIZE AS EXISTING THERMOSTATIC MIXING VALVE, TMV-1 s GAS WATER HEATER 6" DIRT LEG, TYPICAL GWH-1 6" PIPE COLLAR (TYP.) s ASME T&P RELIEF VALVE, TYPICAL THERMOMETER, TYPICAL 3/4" HWC 56"x24"x6" CONCRETE PAD 1-1/4" CW AND 1-1/4" HW TO WATER HEATER, TYPICAL 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f REINFORCED CONCRETE WITH #4 BARS @ 1'-0" O.C. 1-1/4" CW 1B15 CLEANOUT RING AND SOLID COVER (TYP.) 1-1/2" HW (140°F) 1-1/2"" CW 1-1/2"HW LINE SIZE BALL VALVE, TYPICAL TIGHT CLOSING BALANCING VALVE UNION, TYPICAL CHECK VALVE, TYPICAL m GR UP e d e s i g n THERMAL EXPANSION ABSORBER, TEA-1 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: GAS PIPE SIZED PER PLANS, TYPICAL 7 P701 TWO-WAY GRADE CLEANOUT DETAIL 6" HOUSEKEEPING PAD 1 P701 SCALE: NONE GAS FIRED WATER HEATER DETAIL Job #: 755.011 SCALE: NONE High Performance Building Consultants 24" CAST IRON FRAME & TRAFFIC RATED COVER WITH GASTIGHT GASKET, TYPICAL 2" VENT, REFER TO PLUMBING FLOOR PLANS FOR CONTINUATION WASTE OR VENT COLUMN OR PARTITION AS SHOWN ON FLOOR PLAN. PROVIDE CLEANOUT TEE WITH SCREWED COUNTER-SUNK CAST IRON PLUG: TAPERED-THREAD WITH TFE JOINT COMPOUND. www.megroup.com 24" MIN. 3", 6" OR 12" RISER AS REQUIRED 12'-10" 24" INLET INVERT WCO 24" 4" INLET OUTLET INVERT 4" OUTLET WHERE CLEANOUT TEE IS CONCEALED IN A CHASE OR PARTITION, PROVIDE A ROUND 18 GAUGE STAINLESS STEEL COVER WITH BEVELED EDGE. 6" 2" VENT 4" SANITARY PIPE AND ELBOW 5'-2" 4'-2" 4'-0" DIRECTION OF FLOW 7'-10" 3" FLOOR 11'-10" 6" PLAN VIEW 12'-10" DIRECTION OF FLOW 8 P701 TYPICAL WALL CLEANOUT DETAIL 2 P701 SCALE: NONE SAND, OIL AND GAS INTERCEPTOR DETAIL SCALE: NONE FS FS 4" U.L. CHECK VALVE WITH AUTO-BALL DRIP 3" REDUCED PRESSURE BACKFLOW PREVENTOR. SEE FPC SHOP DRAWINGS FOR SIZING AND LAYOUT OF FIRE SPRINKLER ZONES UNION, TYPICAL 3" CW FS TO FIRE DEPARTMENT CONNECTION MEMBRANE CLAMP FLOOR AS REQUIRED FOR DEPTH OF SEWER HUB AND SPIGOT CAST IRON PIPE BELOW FLOOR. SANITARY OR STORM SEWER LINE WATER FLOW SWITCH WITH WIRING TO EXTERIOR AND INTERIOR ALARMS (RE: ELECTRICAL) SAME SIZE AS SEWER UP TO 4" MAXIMUM. U.L. BUTTERFLY VALVE WITH TAMPER SWITCH (RE: ELECTRICAL) LONG SWEEP ELBOW AT END OR TURN OF RUN. COMBINATION WYE AND EIGHTH BEND IN RUN. ENTER TOP OF PIPE. DIRECTION OF FLOW 6" U.L. APPROVED DOUBLE CHECK BACKFLOW PREVENTOR ASSEMBLY, PROVIDE WITH TAMPER SWITCH ON EACH OS&Y GATE VALVE (RE: ELECTRICAL) 2" DRAIN VALVE EXTEND 2" DRAIN THRU EXTERIOR WALL AND TERMINATE WITH 45° ELBOW 3" CW TO PRV STATION 2" DRAIN VALVE WITH 2" DRAIN PIPED TO FLOOR DRAIN PRESSURE GAUGE WITH ISOLATION VALVE, TYPICAL 2" DRAIN VALVE WITH 2" DRAIN PIPED TO FLOOR DRAIN 12" FUNNEL DRAIN. ROUTE 2" TO FLOOR DRAIN/SINK PROVIDE 2" AIR GAP. PROVIDE PIPING SUPPORT FROM WALL AND OR FLOOR, TYP. MAIN WATER SHUT OFF VALVE. 3" CW ENTRY STRAINER WITH BLOW DOWN VALVE AND PIPING TO FLOOR DRAIN/SINK, TYPICAL PRESSURE GAUGE WITH ISOLATION VALVE FLOOR PENETRATION WITH ENTRY FLANGE 6"FIRE 9 P701 TYPICAL FLOOR CLEANOUT DETAIL SCALE: NONE 5 P701 CONCRETE THRUST BLOCK FIRE ENTRY DETAIL 3 P701 SCALE: NONE DOMESTIC CW ENTRY DETAIL SCALE: NONE GFCI FLASHING & COUNTER FLASHING OF VTR IS BY ROOFING CONTRACTOR. PLUMBING CONTRACTOR TO COORDINATE INSTALL. 24" DIAMETER (OR SQUARE) HEAVY DUTY OPEN GRATE BY OTHERS MINIMUM 12" ABOVE ROOF NORMALLY. EXTEND TO HEIGHT OF PARAPET WHEN WITHIN 10'-0" OF PARAPET. CHECK VALVE GATE VALVE RELAY ELEVATOR PIT INTERIOR WELL SEAL (MIDWEST WELL CO.,HUNTLEY, IL)0R EQUAL. STEEL PIPE SLEEVE CORE DRILL ROOF OR PROVIDE SLEEVE IF REQUIRED BY TYPE OF ROOF DECK. PROVIDE FIRE STOP SEAL BETWEEN PIPE & SLEEVE OR DECK ANCHOR PIPE TO ROOF DECK WITH U-BOLT AROUND PIPE & ANGLE IRON WELDED OR SCREWED TO ROOF DECK OR JOIST. MINIMUM 12" BELOW ROOF PROVIDE PIPE INCREASER IF/WHERE CODE REQUIRES A MINIMUM 3" VENT THRU ROOF HUBLESS PIPE CONNECTORS ON CAST IRON PIPE OR BELL & SPIGOT IF PVC. FLOOR NOTE: APPLY (1) WATER-PROOFING COAT TO INTERIOR EQUAL TO DECO #PSC. 24" FLOAT HIGH WATER ALARM (3") NOT FOR CONSTRUCTION OIL SMART PROBE GRADE REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR MINIMUM THREE FEET FROM PROPERTY LINE, OR TEN FEET HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, OR ONE FOOT FROM ANY VERTICAL SURFACE. LOCATE VTR MINIMUM 18" FROM PARAPET, EXPANSION JOINT, EQUIPMENT CURB, ETC. OFFSET IN CEILING SPACE WHERE REQUIRED TO MEET THESE CONDITIONS. 1-1/2" SUMP PUMP DISCHARGE PUMP ON (8") SIMPLEX EELVATOR SUMP PUMP, SEE SCHEDULE. PUMP OFF (4") 24" DIAMETER VENT THRU ROOF DETAIL CONCRETE OR FIBERGLASS SUMP BY MECHANICAL CONTRACTOR OIL SMART PUMP SWITCH PIPE SCALE: NONE OIL SMART ALARM SYSTEM IN JANITOR'S CLOSET ROOF DECK ROOF INSULATION 10 P701 GFCI DESIGN DEVELOPMENT LONG SWEEP AT END OF LINE OR COMBINATION WYE JACKSON, WYOMING RISER LENGTH AS REQUIRED. NOTES: 1. VOLUME OF SECONDARY UNIT TO EQUAL 1/3 TOTAL CAPACITY. 2. PIPES AND FITTINGS TO BE CAST IRON, UNLESS OTHERWISE SPECIFIED. 3. UNIT AND COVER SHALL BE DESIGNED FOR H-20 TRAFFIC WHEEL LOAD. 4. PIT MAY BE POURED MONOLITHIC, COVER MUST BE REMOVABLE. 5. WALLS AND BOTTOM SHALL BE REINFORCED WITH 2x16, 6/10 REMESH. 6. COVER TO BE REINFORCED LONGITUDINALLY WITH #6 REBAR, 8" ON CENTER; #4 REBAR 8" ON CENTER WIDTHWAYS, AND #8 REBAR DIAGONALLY AROUND ACCESS HOLES. 7. PROVIDE COATING FOR ALL EXPOSED INTERIOR SURFACES. 8. GROUT ALL PIPING PENETRATIONS AND JOINTS WATER TIGHT. ELEVATION-SECTION TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 6" HUB AT FLOOR. 6 P701 SLEEVE/SEAL THRU FLOOR DETAIL SCALE: NONE 4 P701 ELEVATOR SUMP PUMP DETAIL SCALE: NONE NOTE: PIPING IN SUMP TO BE MADE UP WITH PRESSURE PIPING TO GRAVITY POINT. 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 4/1/2013 10:18:13 AM CHECKED BY: Checker PLUMBING DETAILS DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: P-501 PLUMBING FIXTURE & EQUIPMENT CONNECTION SCHEDULE FCO GCO FUNCTION FLOOR CLEANOUT GRADE CLEANOUT MANUFACTURER MODEL JOSAM 57000-Z JOSAM WASTE/TRAP VENT CW HW FIXTURE COATED CAST IRON LEVELEZE FLOOR CLEANOUT, INTERAL GASKET, NO-HUB BOTTOM PER - - - WC-1A CONNECTION, SCORIATED SPECIAL DUTY NICKALOY COVER, COORDINATE WITH FLOOR TYPE. PLAN COATED CAST IRON CLEANOUT WITH FLANGE, BOTTOM CONNECTION, INTERAL COUNTERSUNK PER - - - BRONZE PLUG AND SCORIATED ROUND TOP. PLAN BRONZE OR CAST IRON BODIED N.P.T. CLEANOUT WITH PAINTABLE COVER AND SCREW. PER - - - PAINT TO ARCHITECT'S PREFERENCE. PLAN DESCRIPTION 58460A WC-1 WCO TEA-1 WALL CLEANOUT THERMAL EXPANSION ABSORBER JOSAM 58540, 58600 AMTROL ST-30C ASME RATED EXPANSION TANK, STEEL SHELL, POLYPROPYLENE - - 3/4" - - - 1" 1" FUNCTION MANUFACTURER MODEL WATER CLOSET-FLOOR MOUNTED (RESIDENCE UNITS) TOTO CST744EF.10 SEAT TOTO SS114 WATER CLOSET-WALL HUNG KOHLER K-4325 SEAT FLUSH VALVE KOHLER SLOAN K-4666 8111-1.6/1.1 WATER CLOSET-WALL HUNG KOHLER K-4325 DESCRIPTION WASTE/TRAP VENT CW HW UNIVERSAL HEIGHT, ELONGATED FRONT, FLOOR MOUNTED. TWO PIECE, WHITE PLASTIC SEAT AND COVER, 1.28 GPF. 4" 2" 1/2" - WHITE VITREOUS CHINA, SIPHON JET, TOP SPUD, ELONGATED RIM, OPEN FRONT WHITE SOLID PLASTIC SEAT, 1.6/1.1 GPF, AUTOMATIC SENSOR TYPE BATTERY OPERATED FLUSH VALVE. 4" 2" 1" - WHITE VITREOUS CHINA, SIPHON JET, TOP SPUD, ELONGATED RIM, OPEN FRONT WHITE SOLID 4" 2" 1" - 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f FIXTURE PLUMBING FIXTURE & EQUIPMENT CONNECTION SCHEDULE LINER, PAINTED FINISH. WC-2 TMV-1 THERMOSTATIC MIXING VALVE MM430 POWERS 31 GPM @ 10 P.S.I. LOSS MAX, ASSE 1017 LISTED, SET AT 120°F, ROUGH BRASS, MOUNTED ON WALL FOR ACCESS AND ADJUSTMENT. TMV-2 THERMOSTATIC MIXING VALVE LM495 POWERS 4 GPM @ 5 P.S.I. LOSS MAX, ASSE 1017 LISTED, SET AT 110°F, ROUGH BRASS, - - 1/2" 1/2" - - 1/2" - (ACCESSIBLE) SEAT KOHLER K-4666 FLUSH VALVE SLOAN 8111-1.6/1.1 KOHLER K-4960-ET PLASTIC SEAT, 1.6/1.1 GPF, AUTOMATIC SENSOR TYPE BATTERY OPERATED FLUSH VALVE. m GR UP e d e s i g n MOUNTED ON WALL FOR ACCESS AND ADJUSTMENT. U-1 TP-1 TRAP PRIMER 695-01 SIOUX CHIEF AUTOMATIC TRAP PRIMER WITH BUILT IN VACUUM BREAKER. BRASS CONSTRUCTION. URINAL-WALL HUNG PROVIDE WITH LINE SIZE BALL VALVE FOR ISOLATION, LOCATE WITH SERVICE ACCESS. SA-1 SHOCK ARRESTOR SIOUX CHIEF - - FOR ISOLATION AND PROVIDE WITH ACCESS SA-2 SHOCK ARRESTOR SIOUX CHIEF - - FOR ISOLATION AND PROVIDE WITH ACCESS WH-1 WALL HYDRANT WOODFORD PER FLUSH VALVE - 3/4" - 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: SLOAN 8186-0.5 www.megroup.com PER - U-2 - - 3/4" - - - 3/4" - URINAL-WALL HUNG KOHLER K-4960-ET (ACCESSIBLE) PLAN STAINLESS STEEL RECESSED HOLD BOX WALL FLANGE, LOCKABLE DOOR WITH KEY, MODEL B67 1-1/2" PLAN SIZE "C", PISTON-TYPE WATER HAMMER ARRESTOR, PROVIDE WITH LINE SIZE BALL VALVE 652-C 2" WALL THICKNESS. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT. SIZE "A", PISTON-TYPE WATER HAMMER ARRESTOR, PROVIDE WITH LINE SIZE BALL VALVE 652-A WHITE VITREOUS CHINA, SIPHON JET, TOP SPUD, 0.5 GPF AUTOMATIC SENSOR TYPE BATTERY OPERATED FLUSH VALVE, CHROME, PROVIDE CARRIER, COORDINATE WITH FLUSH VALVE WHITE VITREOUS CHINA, SIPHON JET, TOP SPUD, 0.5 GPF AUTOMATIC SENSOR TYPE 2" 1-1/2" 3/4" - Job #: 755.011 BATTERY OPERATED FLUSH VALVE, CHROME, PROVIDE CARRIER, COORDINATE WITH WALL THICKNESS. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT. SLOAN 8186-0.5 STERLING 441908 DELTA 520LF-HDF KOHLER K-2005 High Performance Building Consultants REMOVABLE LOOSE KEY HANDLE, VACUUM BREAKER, COORDINATE ROD DEPTH WHEN ORDERING. HB-1 HOSE BIBB CHICAGO SOLID BRASS, CHROME FINISH, 3/4" HOSE CONNECTION, VACUUM BREAKER, TEE HANDLE. 952-CP L-1A LAVATORY-SELF RIMMING (RESIDENCE UNITS) WHITE VITREOUS CHINA, SELF RIMMING, 4" CENTERS. SINGLE HANDLE MANUAL FAUCET CHROME, 1.0 GPM AERATOR. PROVIDE GRID DRAIN, P-TRAP, 2" 1-1/2" 1/2" 1/2" 2" 1-1/2" 1/2" 1/2" 2" 1-1/2" 1/2" 1/2" 2" 1-1/2" 1/2" 1/2" 2" 1-1/2" 1/2" 1/2" 2" 1-1/2" 1/2" 1/2" 2" 2" 1/2" 1/2" 2" 2" 1/2" 1/2" 3" 2" 1/2" 1/2" 2" 1-1/2" 1/2" - PER PLAN PER PLAN - - - - ANGLE SUPPLIES WITH QUARTER STOPS. GDU-1 GARBAGE DISPOSAL UNIT IMB-1 ICE MAKER BOX IN SINK ERATOR BADGER 5 SIOUX CHIEF 696-10 CONTINUOUS FEED, GALVANIZED STEEL GRINDING ELEMENTS, STAINLESS STEEL SWIVEL 1-1/2" - - - - - 1/2" - FAUCET LUGS, 1/2 H.P., 120/1/60, WITH APPLIANCE PLUG, DISHWASHER CONNECTION. WITH PAINTABLE FACEPLATE AND 1/4 TURN VALVE WITH HAMMER ARRESTOR. PAINT TO MATCH WALL, RE: ARCHITECTURAL DRAWINGS. SIOUX CHIEF (ACCESSIBLE) - WITH PAINTABLE FACEPLATE AND 1/4 TURN VALVE WITH HAMMER ARRESTOR. PAINT TO 696-1 - 1/2" - FAUCET MATCH WALL, RE: ARCHITECTURAL DRAWINGS. GI-1 SAND OIL AND GAS INTERCEPTOR GREASE INTERCEPTOR COPELAND 2000 GALLON COPELAND 500 GALLON MONOLITHIC POURED FLOOR, WITH REINFORCED BOX, VOLUME OF SECONDARY COMPARTMENT PER TO EQUAL 1/3 OF TOTAL CAPACITY. PLAN MONOLITHIC POURED FLOOR, WITH REINFORCED BOX, VOLUME OF SECONDARY COMPARTMENT PER REDUCED PRESSURE WATTS REDUCED PRESSURE ZONE ASSEMBLY, BRONZE BODY, STAINLESS STEEL CHECK 957 REDUCED PRESSURE WATTS REDUCED PRESSURE ZONE ASSEMBLY, BRONZE BODY, STAINLESS STEEL CHECK 909 REDUCED PRESSURE WATTS REDUCED PRESSURE DOUBLE CHECK - L-2 - - 3" - - - 2" - LAVATORY - DROP IN KOHLER K-2906 WHITE VITREOUS CHINA, DROP IN, 4" CENTERS. AUTOMATIC SENSOR TYPE BATTERY (ACCESSIBLE) POWERED FAUCET, CHROME, 0.5 GPM AERATOR. PROVIDE GRID DRAIN, 17 GAUGE P-TRAP, FAUCET SLOAN EBF-187-4 ANGLE SUPPLIES WITH HANDLE STOPS, AND INSULATION KIT (TRUEBRO #105). PROVIDE WITH TMV-2 LOCATED BENEATH SINK AND SET TO 100°F, OR OWNER'S PREFERENCE. S-1A KITCHEN SINK-DOUBLE COMPARTMENT ELKAY GECR3321-6-1/2 - - 1" - - - 2" - - - 6" (FIRE) - 20 GAUGE, TYPE 304 STAINLESS STEEL SINK, 33"x21", SELF RIMMING, 3 HOLE 8" CENTERS FULLY UNDERCOATED, 6-1/2" DEEP, DOUBLE COMPARTMENT. MANUALLY OPERATED CHROME FAUCET WITH ADA HANDLES, 1.6 GPM AERATOR. PROVIDE GAUGE P-TRAP, ANGLE FAUCET DELTA 470-DST SINK-SINGLE COMPARTMENT (ACCESSIBLE ELKAY LRAD1918-6-1/2 FAUCET DELTA 2176-LHP-A24-H24 SINK-DOUBLECOMPARTMENT ELKAY LRAD3321-6-1/2 SUPPLIES WITH QUARTER TURN STOPS, STAINLESS STEEL GRID STRAINER. ASSEMBLIES, QUARTER TURN BALL VALVES, 20 GPM @ 10 PSI LOSS MAX. WATTS REDUCED PRESSURE ZONE ASSEMBLY, BRONZE BODY, STAINLESS STEEL CHECK 909 S-1 ASSEMBLIES, QUARTER TURN BALL VALVES, 50 GPM @ 10 PSI LOSS MAX. BACKFLOW PREVENTOR FBP-1 - (RESIDENCE UNITS) REDUCED PRESSURE ZONE ASSEMBLY, BRONZE BODY, STAINLESS STEEL CHECK 909 BACKFLOW PREVENTOR DBP-4 2" ASSEMBLIES, QUARTER TURN BALL VALVES, 50 GPM @ 10 PSI LOSS MAX. BACKFLOW PREVENTOR DBP-3 - ANGLE SUPPLIES WITH HANDLE STOPS, AND INSULATION KIT (TRUEBRO #105). PROVIDE CARRIER, COORDINATE WITH WALL THICKNESS, REFER TO ARCHITECTURAL DETAILS FOR ASSEMBLIES, QUARTER TURN BALL VALVES, 100 GPM @ 10 PSI LOSS MAX. BACKFLOW PREVENTOR DBP-2 - EBF-187-4 MOUNTING HEIGHT, OR MOUNT SO THAT RIM IS AT 34" A.F.F. (ADA HEIGHT). PROVIDE WITH TMV-2 LOCATED BENEATH SINK AND SET TO 100°F, OR OWNER'S PREFERENCE. PLAN TO EQUAL 1/3 OF TOTAL CAPACITY. DBP-1 3" SLOAN AMES C200 OSY 6" DOUBLE CHECK VALVE ASSEMBLY, TYPE 304 STAINLESS STEEL BODY, SLEEVE ACCESS 19 GAUGE, TYPE 304 STAINLESS STEEL SINK, 19"x18", SELF RIMMING, 3 HOLE 8" CENTERS FULLY UNDERCOATED, 6-1/2" DEEP, SINGLE COMPARTMENT. MANUALLY OPERATED CHROME FAUCET WITH ADA HANDLES, 1.6 GPM AERATOR. PROVIDE GAUGE P-TRAP, ANGLE SUPPLIES WITH QUARTER TURN STOPS, STAINLESS STEEL GRID STRAINER. PORT, OS & Y VALVES, PROVIDE WITH TAMPER SWITCHES BACKFLOW PREVENTOR S-2 (ACCESSIBLE PUMP SCHEDULE MANUFACTURER & MARK SERVES TYPE LOCATION GPM MODEL OR EQUAL HEAD (FT.) MOTOR HP VOLTS/PH/HZ SH-1 BELL AND GOSSET PL-30 BUILDING CENT. MECH. RM 2650 1/12 115/1/60 1 SCP-1 W/ SOLAR PACKAGE SOLAR DHW CENT. MECH RM 2650 1/2 115/1/60 2 ESP-1 SENCOR/OIL MINDER SYS. ELEV. PIT SUBMER. ELEV. PIT 50 20 1,750 1/2 115/1/60 3 ESP-2 SENCOR/OIL MINDER SYS. ELEV. PIT SUBMER. ELEV. PIT 50 20 1,750 1/2 115/1/60 3 NOTES: BT-1 2. PACKAGED SYSTEM WITH CONTROL PANEL, PRESSURE TANK AND ISOLATION VALVES 3. PACKAGED SYSTEM W/ FLOATS CONTROL PANEL AND ALARM MSB-1 GAS/SOLAR WATER HEATER EQUIPMENT SCHEDULE TYPE LOCATION SERVES MODEL OR EQUAL STATE STH-120 WH-1 STATE STH-120 WH-2 GAS GAS MEZZANINE MEZZANINE APT.S/MAIN BLDG APT.S/MAIN BLDG CAPACITY RECOVERY RATE AT (GAL.) 100ºF TEMP. RISE 100 138 100 FAUCET DELTA 2176-LHP-A24-H24 SHOWER VALVE (RESIDENCE UNITS) DELTA T13020 HAND SHOWER DELTA 57014 138 NOTES: DIMENSIONS NOTES 63-1/4"x28" 1,2,3 63-1/4"x28" EWC-1 BATH TUB KOHLER K-715 (LEFT) FAUCET DELTA K-716 (RIGHT) BT13410 HAND SHOWER DELTA 57014 MOP SINK FIAT MSB2424 FAUCET ZURN Z843M1-RC-CS ELECTRIC WATER COOLER 2. PROVIDE WITH COMPLETE SOLAR PACKAGE; SACE 02 400202-T41. SOLAR PANELS(2) CR-110-AP (3.5'x7') DOUBLE WALL HX ,PUMP AND CONTROL PANEL. ASSE 1016 SHOWER SIINGLE HANDLE SHOWER VALVE WITH HAND HELD SHOWER HEAD, SLIDE BAR, 2.0 GPM. REFER TO ARCHITECTURAL DETAILS FOR MOUNTING HEIGHTS. ELKAY 60"x30-1/4"x14' WHITE CAST IRON DROP IN BATH TUB WITH SIDE APRON. PROVIDE WITH STAINLESS STEEL BATH TUB DRAIN. PROVIDE WITH SINGLE HANDLE SHOWER VALVE, DELTA R10000-UNWS OR EQUAL, DIVERTER PLUG AND 2.0 GPM SHOWER HEAD. WHITE MOLDED STONE, 24"x24"x10" MOP SERVICE BASIN. FAUCET TO INCLUDE INTERNAL STOPS AND CHECK STOPS, VACUUM BREAKER, PAIL HOOK AND WALL BRACKET. (ACCESSIBLE) 1,2,3 FD-1 FLOOR DRAIN JOSAM 30000-A FS-1 FLOOR SINK JOSAM 49320A 1. PROVIDE 120V, 1PH; BLOWER 2.2 AMPS, IGNITER 4.0 AMPS; 3. PROVIDE WITH CORD AND PLUG FOR CIRCULATOR PUMP. SUPPLIES WITH QUARTER TURN STOPS, STAINLESS STEEL GRID STRAINER. PROVIDE SHOWER WITH 2" FD-1. 1. PROVIDE WITH AQUA STAT, CHECK VALVE, ISOLATION VALVES ON INLET AND OUTLET OF PUMP MANUFACTURER & FULLY UNDERCOATED, 6-1/2" DEEP, DOUBLE COMPARTMENT. MANUALLY OPERATED CHROME FAUCET WITH ADA HANDLES, 1.6 GPM AERATOR. PROVIDE GAUGE P-TRAP, ANGLE NOTES RPM DCP-1 MARK 19 GAUGE, TYPE 304 STAINLESS STEEL SINK, 33"x21", SELF RIMMING, 3 HOLE 8" CENTERS TD-1 TRENCH DRAIN ZURN Z882 2 PIECE CAST IRON BODY WITH DOUBLE FLANGE, CLAMP RING, ROUND ADJUSTABLE NICKALOY STRAINER, WEEPHOLES, BOTTOM OUTLET 12" SQUARE, 6" DEEP, CAST IRON BODY, ACID RESISTANT INTERIOR, DOUBLE PER PER FLANGE WITH WEEPHOLES, 1/2" GRATE. PLAN PLAN 4" - - - - - - - - - - - - 12" WIDE HIGH DENSITY POLYETHYLENE CHANNEL. PROVIDE WITH HEEL PROOF, ADA, COATED, CAST-IRON GRATE, LOAD CLASS "E". PROVIDE SHOP DRAWING OF SECTIONS TO BE INSTALLED. (STORM) GAS LOAD SCHEDULE SYMBOL RD-1 EQUIPMENT 21500-AE COATED CAST IRON DRAIN WITH POLYPROPYLENE LOCKING DOME, GRAVEL STOP, LARGE MBH GAS WATER HEATER 120 WH-2 GAS WATER HEATER 120 B-1 BOILER 2,500 B-2 BOILER 2,500 B-3 BOILER 2,500 GUH-1 GAS UNIT HEATER 110 GUH-2 GAS UNIT HEATER 110 EQUIPMENT WASHER 510 TOTAL JOSAM SUMP WITH WIDE ROOF FLANGE AND OUTLET, ADJUSTABLE EXTENSION. WH-1 EW-1 ROOF DRAIN PER PLAN (STORM) OD-1 ROOF DRAIN JOSAM 21500-AE-16 COATED CAST IRON DRAIN WITH LEVEL ADJUSTMENT, POLYPROPYLENE STRAINER, NON-PUNCTURING CLAMP RING WITH GRAVEL STOP, 3" INTERNAL WATERGUARD. PER PLAN DSN-1 DOWNSPOUT NOZZLE JOSAM 25010-Z CAST BRONZE DOWNSPOUT NOZZLE WITH LOOSE WALL FLANGE AND NO-HUB INLET (STORM) PER CONNECTION ESEW-1 EMERGENCY SHOWER EYEWASH BRADLEY FLOOR MOUNTED FREE STANDING EMERGENCY SHOWER WITH PULL HANDLE SUSPENDED FROM TOP OF UNIT. ATTACHED BOWL EYEWASH/FACE RINSE. PLAN 1-1/2" DESIGN DEVELOPMENT SOG-1 WHITE VITREOUS CHINA, WALL HUNG, 4" CENTERS. AUTOMATIC SENSOR TYPE BATTERY POWERED FAUCET, CHROME, 0.5 GPM AERATOR. PROVIDE GRID DRAIN, 17 GAUGE P-TRAP, JACKSON, WYOMING WASHER BOX LAVATORY-WALL HUNG TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY WB-1 L-1 8,470 NOTE; GAS PROVIDED AT 2 LBS. NOT FOR CONSTRUCTION 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker PLUMBING SCHEDULES 4/1/2013 10:18:14 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: P-601 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 GENERAL NOTES FOR CNG FUELING SYSTEM INSTALLATION: 20. EQUIP THE CNG FUELING STATION WITH A PLC-BASED CONTROL SYSTEM. THE CONTROL SYSTEM SHALL AUTOMATICALLY START AND STOP THE COMPRESSORS, BASED ON DISCHARGE-LINE PRESSURES, STORAGE VESSEL PRESSURES, AND TIME OF DAY. THE CONTROL SYSTEM SHALL INITIATE EMERGENCY SHUTDOWN OF STATION SYSTEMS, ACCORDING TO THE "ESD CONTROL MATRIX FOR CNG FUELING STATION", AS SHOWN BELOW. 1. ABOVEGROUND GAS SERVICE PIPING BETWEEN THE METER SET ASSEMBLY, GAS DRYER AND CNG COMPRESSOR SHALL BE INSTALLED ABOVEGROUND AND BE SEAMLESS CARBON STEEL, ASTM A106, GRADE B, SCHEDULE 40, OR HDPE 'DR11' PIPE. STEEL NATURAL GAS PIPING SHALL BE WELDED OR FLANGED, WITH THE FOLLOWING EXCEPTION. EQUIPMENT CONNECTIONS NPS 1, OR SMALLER, REQUIRING PERIODIC SERVICING MAY BE MADE USING NPT. WELDED STEEL PIPE CONNECTIONS EQUAL OR LARGER THAN NPS2 SHALL BE BUTT WELDED, OR OTHERWISE SOCKET WELDED. FLANGED CONNECTIONS SHALL BE CLASS 150, RAISED FACE, FORGED CARBON STEEL, ASTM A105, CONFORMING TO ANSI B16.5. ESD CONTROL MATRIX FOR CNG FUELING SYSTEM Responses Shut down Close Close Shut down Call out to Condition CNG all site fast fill designated Compr. supply ESD dispenser valves personnel Skid A valve Manual ESD button is pushed at any location X X X X X except connected to compressor skid Manual ESD button on 0 0 0 X X CNG Skid A is pushed Excess flow is metered X X X X X at fast fill dispenser In CNG Skid A: low methane leak (25% LFL), high vibration, high oil pressure, high X 0 0 0 X cylinder temperature, low inlet pressure, high inlet pressure, or motor fault alarms are set High methane leak X X X X X ( 50% LFL) is detected in CNG Skid A Response is initiated X Key to Responses Response is not initiated 0 2. UNDERGROUND GAS PIPING SHALL BE INSTALLED NOT LESS THAN 24" BELOW GRADE. A. UNDERGROUND GAS SERVICE PIPING SHALL BE SCHEDULE 80 CS (A104 GRADE B). B. ABOVEGROUND STEEL GAS SERVICE PIPING SHALL BE SCHEDULE 40 CS (A104 GRADE B) WITH ZINC OXIDE PRIMER AND GREEN EPOXY TOP COAT. C. UNDERGROUND PLASTIC PIPING W/ A SERVICE PRESSURE OF LESS THAN 90 PSIG SHALL BE HDPE SDR11 WITH TRACE WIRE AND ANODELESS RISERS. 3. WARNING TAPE SHALL BE PLACED IN PIPE TRENCH BACKFILL, APPROXIMATELY 1 FT. ABOVE TOP OF PIPE. USE YELLOW POLYETHYLENE TAPE MANUFACTURED FOR IDENTIFYING UNDERGROUND UTILITIES, 6 IN. WIDE AND 4 MILS THICK, CONTINUOUSLY INSCRIBED WITH "GAS". 4. HIGH PRESSURE CNG PIPING DOWNSTREAM FROM COMPRESSOR DISCHARGE SHALL BE SEAMLESS CARBON STEEL, ASTM A106, GRADE B. NPS 1 AND SMALLER PIPE SHALL BE SCHEDULE 160; NPS 1 1/2 AND NPS 2 SHALL BE XXS. NOMINAL PIPE SIZES SHALL BE 3/4 OR 1, AS SHOWN IN THE DRAWINGS. HIGH PRESSURE CNG PIPING WITH DIAMETERS OF NPS 2 OR SMALLER SHALL BE SOCKET WELDED. SOCKET WELD FITTINGS SHALL BE FORGED STEEL, ASTM A105, CLASS 6000, & MANUFACTURED PER ANSI B16.11-2001. 5. FLANGES FOR HIGH PRESSURE CNG PIPING SHALL BE CLASS 2500 FORGED STEEL, ASTM A105, WELDNECK, RTJ OR RF, CONFORMING TO ANSI B16.5, WITH BORE MATCHING THE INSIDE DIAMETER OF THE CONNECTED PIPE. 6. FLANGE BOLTS SHALL BE HEAVY HEXAGONAL CAP SCREWS, ASTM A307 GRADE B, WITH HEAVY HEX NUTS, ASTM A194, GRADE 2H. PIPE FLANGE BOLTS SHALL SHOW A MINIMUM OF 2 THREADS THROUGH THEIR BACKING NUT, WHEN FULLY TIGHTENED. K 7. INSULATED FLANGES: FURNISH FLANGE INSULATING KITS WHERE INDICATED IN THE DRAWINGS. A) KITS FOR RAISED FACE FLANGES SHALL INCLUDE AN INSULATED FULL-FACED FLANGE GASKET, PIPELINE SEAL & INSULATOR, INC., LINE BACKER TYPE E, 1/8 " THICK, WITH PHENOLIC RETAINER AND VITON SEALING ELEMENT. KITS FOR RING-TYPE JOINTS SHALL INCLUDE A TYPE D GASKET. B) ALL INSULATING KITS SHALL INCLUDE THE FOLLOWING: I) ONE FULL-LENGTH PHENOLIC SLEEVE, EXTENDING HALF-WAY INTO BOTH STEEL WASHERS FOR EACH FLANGE BOLT. THE SLEEVE SHALL BE A 1/32 " THICK TUBE. II) 2-EA, 1/8 " THICK PHENOLIC ISOLATING WASHERS FOR EACH BOLT. III) 3-EA, 1/8 " THICK ZINC-PLATED, HOT ROLLED STEEL WASHERS FOR EACH BOLT. THE I. D. OF ALL WASHERS SHALL FIT OVER THE ISOLATING SLEEVE, AND BOTH THE STEEL- AND ISOLATING WASHERS SHALL HAVE THE SAME I.D. AND O.D. PHENOLIC SLEEVES SHALL HAVE A MIN. DIELECTRIC STRENGTH OF 400 VOLTS/MIL, AND WATER ABSORPTION OF 0.10% OR LESS. J 8. PIPE PROTECTION: A) ALL UNDERGROUND STEEL GAS PIPING THAT IS DIRECTLY BURIED SHALL BE FACTORY COATED WITH FUSION-BONDED EPOXY, CONFORMING TO NACE RP0394 - STANDARD RECOMMENDED PRACTICE, "APPLICATION, PERFORMANCE, AND QUALITY CONTROL OF PLANT-APPLIED FUSION-BONDED EPOXY EXTERNAL PIPE COATING". COATING SHALL BE 3M "SCOTCHKOTE 6233" OR APPROVED EQUAL. PIPE JOINTS SHALL BE PREPARED AND FIELD-COATED ACCORDING TO THE FACTORY COATING MANUFACTURER'S WRITTEN RECOMMENDATIONS. B) PIPING SHALL ALSO BE CATHODICALLY PROTECTED (CP) BY MAGNESIUM-BASED SACRIFICIAL ANODES WITH TEST STATIONS. CP SYSTEM SHALL BE DESIGNED BY AN ENGINEER THAT IS QUALIFIED AND EXPERIENCED FOR THE WORK AND THAT HAS A WYOMING P.E. LICENSE. DESIGN FOR CP SYSTEM SHALL BE PROVIDED AS A DEFERRED SUBMITTAL. I J 22. CONTRACTOR SHALL PROVIDE EQUIPMENT AS DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. OTHER EQUAL PRODUCTS MAY BE SUBSTITUTED ONLY WITH THE OWNER'S PRIOR APPROVAL, IN WRITING. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CHANGES TO THE APPROVED CONSTRUCTION DRAWINGS THAT RESULT FROM THE SUBSTITUTION OF EQUIPMENT SHOWN IN THE PLANS. I 23. CONTRACTOR SHALL PROVIDE EQUIPMENT, MATERIALS, CONSTRUCTION, START-UP, AND 12-MONTH WARRANTY OF MATERIALS AND WORKMANSHIP FOR THE FUELING FACILITY PER THE SPECIFICATIONS AND DRAWING PACKAGE. 10. ALL FLEXIBLE PIPE CONNECTORS SHALL BE CONSTRUCTED USING TYPE 316 STAINLESS STEEL FITTINGS AND BRAIDS, AND PTFE LINERS. PERMANENTLY LABEL FLEX CONNECTORS WITH MAWP, MANUFACTURER'S NAME, AND MODEL NO. 24. CONTRACTOR SHALL PROVIDE RED-LINED FIELD DRAWINGS SHOWING ALL SIGNIFICANT CHANGES TO THE APPROVED DRAWINGS. 11. CONTRACTOR SHALL FURNISH ALL PIPE, TUBING AND WELD FITTINGS. SUBMIT MATERIAL CERTIFICATIONS FOR ALL GAS PIPE AND PIPE-FITTINGS. WELDING ON GAS PIPE AND TUBE SHALL BE PERFORMED IN ACCORDANCE WITH ASME/ANSI B31.3. WELDING PROCEDURES SHALL BE QUALIFIED IN ACCORDANCE WITH ASME BOILER AND PRESSURE VESSEL CODE, SECTION IX. QUALIFIED WELD PROCEDURES & WELDERS' CERTIFICATIONS SHALL BE KEPT ON FILE AND AVAILABLE FOR INSPECTION BY THE OWNER'S REPRESENTATIVE. NO WELDING SHALL BE PERFORMED BY ANY WELDER FOR WHOM A CURRENT CERTIFICATION IS NOT ON FILE. USING ALIGNMENT LUGS IS ACCEPTABLE, BUT LUGS SHALL BE CUT OFF AND GROUND FLUSH AFTER WELDING IS COMPLETE. H SCOPE OF WORK: THE CONTRACTOR SHALL INSTALL A NEW, COMPLETE CNG FUELING SYSTEM TO PROVIDE FLEET FAST-FILL CNG VEHICLE FUELING. 12. CONTRACTOR SHALL PROVIDE AND PAY FOR THE INSPECTION AND LEAK TESTING OF ALL FIELD FABRICATED TUBING AND WELDED GAS PIPING. CONTRACTOR SHALL UTILIZE A QUALIFIED INSPECTOR TO INSPECT WELDS IN ACCORDANCE WITH CHAPTER VI OF ASME B31.3. EVERY WELD SHALL BE EXAMINED VISUALLY. ALL BUTT WELDS SHALL BE RADIOGRAPHED, AND WRITTEN TEST REPORT(S) FURNISHED TO THE ENGINEER, BEFORE PRESSURIZING THE PIPE. EXAMINE NOT LESS THAN 25% OF ALL SOCKET WELDS BY DYE PENETRATION, AND FURNISH WRITTEN TEST REPORT(S) TO THE ENGINEER, BEFORE PRESSURING THE PIPE. G K 21. THE OWNER SHALL FURNISH ALL EQUIPMENT, AND PERFORM ALL INSTALLATION, TESTING, AND STARTUP NEEDED TO PROVIDE A COMPLETE AND FUNCTIONAL CNG FUELING SYSTEM. SCOPE INCLUDES INSTALLATION OF THE FOLLOWING MATERIALS AND PACKAGED EQUIPMENT: 9. EXCEPT AS NOTED, ALL BALL VALVES USED IN NATURAL GAS PIPING SHALL HAVE TYPE 316 STAINLESS STEEL BALLS, BODIES AND STEMS; HOWEVER, FACTORY-PAINTED VALVES NPS2 AND LARGER MAY HAVE CARBON STEEL BODIES. H L EQUIPMENT SIZING. - SUCTION-SIDE GAS DRYER WITH ONE DESICCANT TOWER, BYPASS, ONBOARD REGENERATION, AND MAXIMUM 5 PSI PRESSURE DROP AT 800 SCFM. - TWO CNG-COMPRESSOR SKIDS WITH 250 HP MOTOR DRIVE AND MINIMUM 400 SCFM CAPACITY EACH, DISCHARGING AT 4500 PSIG BASED ON THE GAS-SUPPLY DESIGN CONDITIONS, PROVIDED WITHOUT SKID ENCLOSURES AND HOUSED IN THE CNG BUILDING. - DESIGN AND INSTALLATION OF COOLER-DISCHARGE DUCTING FOR ROUTING COMPRESSOR-COOLER DISCHARGE OUT OF CNG BUILDING. - (4) CNG STORAGE VESSELS EACH WITH A MINIMUM OF 10,500 SCF OF CNG AT 4500 PSIG AND MAWP OF 5500 PSIG. - BUFFER VALVE PANEL HOUSED IN A NEMA 1 ENCLOSURE, AND HOUSED IN THE CNG BUILDING. 13. CNG TUBING - HIGH PRESSURE TUBING SHALL BE SEAMLESS, AND MANUFACTURED AND LABELED ACCORDING TO ASTM A-213, USING TYPE 316 OR 304 S.S. TUBING WITH DIAMETERS LESS THAN 3/4" SHALL BE CONNECTED USING TYPE 316 SS SWAGED FITTINGS. ALL SWAGED FITTING SHALL BE FROM A SINGLE MANUFACTURER. ACCEPTABLE PRODUCTS ARE SWAGELOK, HOKE GYROLOK OR PARKER A-LOK. SWAGED FITTING SHALL HAVE A MINIMUM WORKING PRESSURE RATING OF 5500 PSI. PRESSURE TUBING 3/4" AND LARGER SHALL BE JOINED USING PARKER SEAL-LOK FACE SEAL FITTINGS. O-RING MATERIAL FOR FACE SEAL FITTINGS SHALL BE VITON ALL SS TUBING FITTINGS SHALL BE PARKER. ALL SS TUBING SHALL BE MARKED 'MADE IN USA'. G F F 14. PRESSURE TUBING SHALL HAVE THE FOLLOWING MINIMUM WALL THICKNESS. TUBE NOMINAL SIZE TUBE OD (INCHES) WALL THICKNESS (INCHES) 0.250 0.035 0.375 0.049 0.500 0.065 0.750 0.109 1.000 0.120 1.500 0.188 E NGV-1 TYPE-2 P36 NOZZLES. - CONNECTION OF DISPENSERS TO FUEL-MANAGEMENT TERMINALS AS SHOWN ON 'DL' SERIES PETROLEUM-FUELING DRAWINGS. - ISLANDS, FLEET DISPENSER AND FUEL-MANAGEMENT TERMINALS SHALL BE CONFIGURED AND INSTALLED SO THAT THEY ARE ADA COMPLIANT. - PROVIDE PRE-ENGINEERED CATHODIC-PROTECTION SYSTEM FOR ALL BURIED STEEL PIPING. INCLUDES DEFERRED DESIGN SUBMITTAL SEALED BY A WY-REGISTERED ENGINEER THAT IS PRACTICED IN THE DESIGN OF CATHODIC PROTECTION SYSTEMS. SYSTEM SHALL INCLUDE TEST STATIONS AND COMMISSIONING REPORT. - PROVIDE 12-MONTH COMPREHENSIVE PARTS AND LABOR WARRANTY ON ALL EQUIPMENT, MATERIALS AND SYSTEMS INSTALLED, EXCLUSIVE OF CONSUMABLES SUCH AS LUBE OIL AND OTHER WEAR PARTS PER MANUFACTURER'S PUBLISHED DATA. - PROVIDE 3 SETS OF BOUND AND INDEXED OWNER'S MANUALS FOR ENTIRE SYSTEM AS INSTALLED. - PROVIDE RED-LINED FIELD DRAWINGS AND AS-BUILT DRAWINGS IN PDF AND AUTOCAD FORMATS SHOWING CLOUDED CHANGES 15. PRESSURE TESTING OF CNG PIPING. BEFORE CONNECTING THE CNG PIPING AND TUBE TO THE NEW STORAGE VESSELS, ALL HIGH-PRESSURE CNG PIPING AND TUBING SHALL BE INSPECTED, LEAK TESTED, AND PRESSURE TESTED WITH NITROGEN. THE TEST GAS SOURCE SHALL BE CAPABLE OF PRESSURIZING THE PIPING TO NOT LESS THAN 5,500 PSIG. PERFORM TESTING IN THE FOLLOWING STEPS. A) COMPRESS PIPING TO 25 PSIG AND SOAP-TEST ALL JOINTS FOR LEAKS. IF ANY LEAKAGE IS DETECTED, RELIEVE THE PRESSURE AND REPAIR THE LEAK(S). REPEAT TESTING AT 25 PSIG UNTIL ALL LEAKS ARE ELIMINATED. B). CONNECT A PRECISION (<1% ERROR) PRESSURE TRANSDUCER AND DATA RECORDER TO THE CNG PIPING SYSTEM, AND ARRANGE THE VALVING TO SEAL THE SYSTEM AND ALLOW ISOLATE IT TO BE ISOLATED FROM THE PRESSURE SOURCE. SLOWLY INCREASE THE PRESSURE TO 500 PSIG, AND INSPECT FOR LEAKS. INCREASE PRESSURE AGAIN, IN 1000 PSI INCREMENTS, TO 5,500 PSIG. HOLD PRESSURE CONSTANT FOR AT LEAST 10 MINUTES BEFORE INCREASING TO THE NEXT INCREMENT. WITH THE SYSTEM PRESSURIZED TO 5,500 PSIG, AND ISOLATED FROM THE PRESSURE SOURCE, ADEQUATE LEAK INTEGRITY SHALL BE VERIFIED BY NO LOSS OF PRESSURE OVER A PERIOD OF AT LEAST 2 HR. SUBMIT A RECORD OF PRESSURE, MEASURED AT 10 MIN. INTERVALS, AS EVIDENCE OF SUCCESSFUL PRESSURE TESTING. C). AFTER PNEUMATIC TESTING, RELIEVE THE PIPING SYSTEM PRESSURE TO ATMOSPHERIC, CONNECT IT TO NATURAL GAS COMPRESSOR(S) AND STORAGE, AND PURGE WITH NATURAL GAS. PRESSURIZE WITH NATURAL GAS AND INSPECT FOR LEAKS WITH SOAP BUBBLE TEST AT NORMAL OPERATING PRESSURES. D THE WORK SHALL CONFORM TO THE CURRENTLY ADOPTED EDITION OF THE FOLLOWING CODES AND STANDARDS AS SUPPLEMENTED, AMENDED, OR MODIFIED BY STATE OF WYOMING AND TOWN OF JACKSON: - INTERNATIONAL BUILDING CODE (IBC) - INTERNATIONAL PLUMBING CODE (IPC) - INTERNATIONAL MECHANICAL CODE (IMC) - INTERNATIONAL FUEL GAS CODE (IGC) - INTERNATIONAL ELECTRIC CODE (IEC) - INTERNATIONAL FIRE CODE (IFC) - NFPA 30A 2008 - MOTOR FUEL DISPENSING FACILITIES AND REPAIR GARAGES - NFPA 52 2010 - VEHICULAR GASEOUS FUEL SYSTEMS 16. PRESSURE TEST INSTRUMENT AIR/GAS PIPING BY PRESSURIZING WITH NITROGEN TO 200 PSIG, AND SOAP TESTING WITH NO LEAKAGE AT ANY VALVE OR FITTING. WITH THE AIR/GAS PIPING SEALED AT ALL ABOVEGROUND RISERS, AND COMPRESSED TO 200 PSIG, THE AIR PIPING SHALL DEMONSTRATE NO LOSS OF PRESSURE OVER 1 HR, AS INDICATED BY A 1% PRECISION BOURDON TUBE GAUGE. THE GAUGE SHALL HAVE A FULL-SCALE PRESSURE OF 250 PSIG. DO NOT BACKFILL PIPE TRENCHES UNTIL LEAK TESTING HAS BEEN SUCCESSFULLY COMPLETED. C D NOT FOR CONSTRUCTION C IN THE EVENT OF A CONFLICT BETWEEN DRAWINGS, WRITTEN SPECIFICATIONS, AND/OR REFERENCED STANDARDS, THE MOST STRINGENT SHALL GOVERN SUBMITTALS 17. LEAK TESTING OF NATURAL GAS SERVICE PIPING. NATURAL GAS PIPING FROM THE METER TO THE COMPRESSORS SHALL BE LEAK TESTED WITH NITROGEN, ACCORDING TO APPLICABLE UTILITY COMPANY GAS TEST PROCEDURES, TEST SHALL INCLUDE HOLDING MAWP FOR 20 MINUTES AND SOAP BUBBLE TEST OF ALL JOINTS AND UNIONS. - PRODUCT DATA SHEETS FOR ALL EQUIPMENT LISTED UNDER SCOPE OF WORK SECTION OF THIS SHEET. - DATA SHEETS FOR ALL PIPING, TUBING, VALVES AND PIPING APPURTENANCES THAT ARE FIELD INSTALLED. - DOCUMENTATION SHOWING ALL EQUIPMENT INSTALLED IN UNCONDITIONED SPACE IS LISTED FOR TEMPERATURES AS LOW AS 18. PERFORM LEAK TESTING AND WELD INSPECTIONS OF STEEL PIPING BEFORE APPLYING FIELD COATINGS OR PAINT. B E B 1 - DEFERRED DESIGN SUBMITTAL FOR CATHODIC PROTECTION SYSTEMS NEEDED FOR DIRECT-BURIED PIPING, INCLUDING P.E. SEAL BY ENGINEER LICENSED IN WYOMING. - DEFERRED DESIGN SUBMITTAL FOR DUCTING AT COMPRESSOR SKID COOLER DISCHARGE, AS REQUIRED TO ROUTE COOLER DISCHARGE OUT OF CNG BUILDING. - OTHER SUBMITTALS AS REQUIRED IN THE SPECIFICATION MANUAL. 19. CONTRACTOR SHALL VERIFY DIMENSIONS AND INTERFACES FOR EQUIPMENT, PENETRATIONS, PIPING AND POINTS OF CONNECTION FOR CONSISTENCY WITH EQUIPMENT SHOP DRAWINGS, PRIOR TO CONSTRUCTION. A DESIGN DEVELOPMENT 4/8/13 CNG Fueling Notes A DRAWN BY: CHECKED BY: DESIGN DEVELOPMENT L M JACKSON, WYOMING M N TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DG001 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 N N M M L L K K J J SEE DWG DG-102 FOR CNG EQUIPMENT PLAN I I H H SEE DWG DG-102 FOR CNG EQUIPMENT PLAN F SEE DWG DL101 FOR PETROL EQUIPMENT PLAN E E D D DESIGN DEVELOPMENT F JACKSON, WYOMING G TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY G NOT FOR CONSTRUCTION C C B B 1 4 8 16 NORTH A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 4/8/13 Fuel Systems Site Plan 32 A DRAWN BY: CHECKED BY: 0 DESIGN DEVELOPMENT 16 17 18 DG101 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 NOTE: N 1. N SEE DWG DG601 FOR CNG HEX CALL-OUT EQUIPMENT DESCRIPTIONS. M M L L K K J J 28 I 27 I 27 23 H H 23 22 F 26 F 29 E E D D DESIGN DEVELOPMENT 25 JACKSON, WYOMING G TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY G 24 NOT FOR CONSTRUCTION C C B B 1 2 4 8 4/8/13 CNG Fuel Equipment Plan 16 A A NORTH DRAWN BY: CHECKED BY: 0 DESIGN DEVELOPMENT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DG102 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 N N SCHEDULE OF EQUIPMENT FOR CNG FUELING FACILITY KEY NO. M ITEM QTY. REQ'D SPECIFICATION MFR. & MODEL M CNG EQUIPMENT 1 NATURAL GAS DRYER 1 SINGLE-VESSEL DESICCANT DRYER, 800 SCFM MINIMUM CAPACITY AT 38 PSIG, NPS 4" CLASS 150 RF FLANGE CONNECTIONS, 150 PSIG MAWP, INTEGRAL MANUALLY-CONTROLLED REGENERATION SYSTEM, BYPASS VALVES, HYGROMETER W/ 2-LEVEL ALARM, INLET-COALESCING AND OUTLET-PARTICULATE FILTERS; TOTAL PRESSURE DROP ? 5 PSI AT DESIGN CONDITIONS, AND INSTALL IN CNG BUILDING. PSB MODEL NGSR-15-4 OR EQUAL XEBEC (SEE NOTE 3) 2 CNG COMPRESSOR SKIDS 2 ANGI NG300E OR EQUAL ATLAS COPCO/GF CT OR IMW-50 (SEE NOTE 3) 3 CNG GROUND STORAGE VESSELS 4 4 CNG FLEET DISPENSER 1 EACH SKID EQUIPPED WITH (1) CNG COMPRESSOR RATED AT 400 SCFM AT COMPRESSOR SUCTION OF 33 PSIG, DRIVEN BY A 250 HP NEMA PREMIUM EFFICIENCY TEFC MOTOR. FURNISH WITH MASTER & AUXILIARY PLC'S, INTERSTAGE COOLER, AIR-ACTUATED BALL VALVES, RECEIVER FOR CAPTURED BLOWDOWN, AND COLD-WEATHER BLOCK HEATER. INSTALL IN CNG BUILDING AND PROVIDE WITHOUT SKID ENCLOSURES. REGULATE GAS-SUCTION PRESSURE AFTER DRYER AS REQUIRED BY COMPRESSOR-SUCTION LIMITATIONS. PROVIDE DUCTING FROM COOLER DISCHARGES TO BUILDING OPENING. TUBULAR VESSEL WITH 10,500 SCF MINIMUM CAPACITY (EA) AT 4500 PSIG, 5500 PSIG MAWP, WITH SUPPORT, ISOLATION VALVES AND PRESSURE RELIEF VALVES. PACKAGE VESSELS AND PROVIDE FOUNDATIONS AS REQUIRED TO SUPPORT 6 TOTAL VESSELS. TWO-HOSE DISPENSER WITH ONE-LINE X 3/4" BUFFER-TYPE CONFIGURATION AND (2) J4 COALESCING FILTERS, TWO MICROMOTION CNG-050 FLOW METERS, AND INTERNAL 'SMART DISPENSER' FILL LOGIC FOR DELIVERING FILLS TEMPERATURE COMPENSATED TO 3600 PSIG L K 5 J 6 "CNG TRANSIT DISPENSER " ESD BUTTON 1 3 I H 7 INTEGRATED CONTROL/STARTER PANEL 1 8 CNG BUFFER-VALVE PANEL 1 1/2" X 12' HOSES AND NGV-1 TYPE-2 P36 NOZZLES. CONTROLS SHALL BE CONFIGURED PER ADA REQUIREMENTS, WITH ALL USER-INTERFACE ELEMENTS A MAXIMUM OF 54" ABOVE THE DRIVEWAY SURFACE. DISPENSER SHALL BE APPROVED AND PACKAGED BY THE COMPRESSOR-SKID PACKAGER. TWO-HOSE TRANSIT DISPENSER WITH ONE-LINE X 3/4" BUFFER-TYPE CONFIGURATION AND (2) J4 COALESCING FILTERS, ONE MICROMOTION CNG-050 FLOW METER, AND INTERNAL 'SMART DISPENSER' FILL LOGIC FOR DELIVERING FILLS TEMPERATURE COMPENSATED TO FURNISHED WITH (1) 3/4" X 12' HOSE AND SHEREX CT-5000 NOZZLE, AND WITH (1) 1/2" X 12' HOSE AND NGV-1 P36 NOZZLE. DISPENSER SHALL BE APPROVED AND PACKAGED BY THE COMPRESSOR-SKID PACKAGER. EMERGENCY SHUTDOWN BUTTON, WIRED NORMALLY CLOSED / FAIL OPEN W/ SERIAL 120V CIRCUIT WIRED TO MASTER CONTROL PANEL/PLC. CLASS 1 DIVISION 2 RATED, MAINTAIN OPEN ON ACTIVATION. INCLUDE CLEAR FLIP COVER. INCLUDE RELAY INTERFACE TO ESD CIRCUIT FOR PETRO POWER-CONTROL PANEL 'PP1' FOR SIMULTANEOUS ESD ACTIVATION OF PETROL SYSTEM. POWER DISTRIBUTION TO ALL 3-PHASE AND 1-PHASE ELECTRICAL LOADS FOR COMPRESSOR OPERATION INCLUDING 2 X 250HP COMPRESSOR MOTORS, 2 x 20 HP COOLER-FAN MOTORS, AND 1-PHASE TRANSFORMER FOR 120V CONTROL LOADS. INCLUDES INTEGRATED PLC FOR MONITORING AND CONTROL OF BOTH COMPRESSORS, IP COMMUNICATION CAPABILITY, AND I/O CAPABILITY FOR COMMUNICATION VIA WEB-BASED INTERFACE FOR STATUS, FAULT HISTORY AND PARAMETER MODIFICATIONS. ALL MOTORS ABOVE 10 HP SHALL HAVE ELECTRONIC SOFT STARTERS. PANEL SHALL BE APPROVED AND PACKAGED BY THE COMPRESSOR-SKID PACKAGER. EQUIPPED WITH 1" X 5000 PSI ADJUSTABLE BACK-PRESSURE REGULATOR, AIR-ACTUATED BALL VALVES AND CONTROLS TO DIRECT CNG FROM CNG SKIDS TO THE CNG DISPENSERS IN CONNECTION WITH ONE-BANK BUFFER STORAGE ASSY, AND EMERGENCY SHUT DOWN ISOLATION OF BUFFER STORAGE. FURNISH WITH 3/4" TUBING AND HOUSE IN A NEMA 1 ENCLOSURE AND LOCATE IN CNG BUILDING. PANEL SHALL BE APPROVED AND PACKAGED BY THE COMPRESSOR-SKID PACKAGER. L CP INDUSTRIES, OR FIBA ANGI OR EQUAL ATLAS COPCO/GF, KRAUS GLOBAL OR TULSA GAS TECH K ANGI OR EQUAL ATLAS COPCO/GF, KRAUS GLOBAL OR TULSA GAS TECH J APPLETON OR EQUAL I SQUARE-D, ABB OR EQUAL, AS PACKAGED BY ANGI, ATLAS COPCO, OR IMW H ANGI OR EQUAL ATLAS COPCO, IMW OR TULSA GAS TECH SCHEDULE NOTES G G 4 F F E E D D DESIGN DEVELOPMENT 3 THE LIST OF EQUIPMENT GIVEN HERE IS PARTIAL. CONTRACTOR SHALL FURNISH ALL EQUIPMENT. LABOR, CONDUIT, WIRE, PIPING, MATERIAL AND TESTING SERVICES TO DELIVER A COMPLETE FUNCTIONAL CNG FUELING SYSTEM REQUIRED BY PLANS, DRAWINGS, AND SPECIFICATIONS, AND AS APPROVED BY THE OWNER. REFER TO THE SPECIFICATION SECTION 430105 FOR ADDITIONAL REQUIREMENTS. EQUIPMENT MANUFACTURERS AND MODELS LISTED ARE FOR THE PURPOSE OF ESTABLISHING THE BASIS OF DESIGN. ALTERNATE MANUFACTURERS AND MODELS MAY BE ACCEPTED, IF THEY PROVIDE OR EQUAL FUNCTIONAL PERFORMANCE, IF THEY FIT THE AVAILABLE SPACE, AND IF THEY ARE APPROVED BY THE OWNER. JACKSON, WYOMING 2 SEE DRAWING FD-101 FOR LOCATION OF KEYED EQUIPMENT. TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 1 NOT FOR CONSTRUCTION C C B B 1 DESIGN DEVELOPMENT 4/8/13 A A DRAWN BY: CHECKED BY: CNG Equipment Schedule 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DG601 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 N N NOTES: 1. ALL HIGH PRESSURE CNG PIPING AND TUBING SHALL HAVE A MAWP OF 5000 PSIG OR GREATER. 2. PIPE CONTROL AIR TO GAS DRYER ONLY IF DRYER REQUIRES PURGE AIR. M 400 SCFM 4 STAGE COMPRESSOR SKID W/ 250HP ELECTRIC MOTOR L 3. WIRE TO PHONE BOARD OR I.P. NETWORK. 4. SOLENOID VALVES IN DISPENSERS SHALL BE LOCATED DOWNSTREAM OF FILTERS. 5. ESD VALVES SHALL ONLY OPEN ON FLOW DEMAND. 6. ALL GAS SHUTOFF VALVES SHALL HAVE A SAFETY FACTOR OF 3X NORMAL WORKING PRESSURE. 7. ALL PRESSURE RELIEF VALVES, INCLUDING THOSE CONTAINED IN PRE-PACKAGED EQUIPMENT, SHALL BE RECERTIFIED EVERY 3 YEARS. 8. WIRE AND INTERFACE ESD CIRCUIT TO PETRO POWER PANEL PP1 FOR COMMON ESD FUNCTION. 9. COORDINATE WIRING OF CNG DISPENSERS TO FM TERMINALS IN CONJUNCTION WITH PETROL FUEL REQUIREMENTS. SEE PETROL DRAWINGS AND SPECIFICATINS FOR FM REQUIREMENTS. SEE NOTE #3 K CONNECT TO AIR COMPRESSOR AND DRYER IN CNG-ELECTRICAL ROOM PER Q-SERIES DRAWINGS J M L K J SYMBOLS AND LEGEND I I 400 SCFM 4 STAGE COMPRESSOR SKID W/ 250HP ELECTRIC MOTOR G F F E E D D DESIGN DEVELOPMENT G JACKSON, WYOMING H TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY H SEE NOTE 2 NOT FOR CONSTRUCTION C C 3 4" FUTURE CONNECTION B B 1 S.S. 4/8/13 CNG Piping Flow Diagram C.S. A A DRAWN BY: CHECKED BY: DESIGN DEVELOPMENT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DG611 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 N N SCOPE OF WORK AND GENERAL NOTES FOR PETROLEUM FUELING FACILITY: 1) THE PETROLEUM FUELING AND UST SYSTEM WORK CONSISTS OF THE FOLLOWING SCOPE: A) (1) 20,000-GAL. DIESEL-FUEL UST WITH DOUBLE-WALL (2) 2 HP SUBMERGED TURBINE PUMPS IN ONE TANK, INCLUDING DOUBLE-WALL CONTAINMENT SUMPS AND APPURTENANCES. TANK AND SUMPS SHALL BE HYDROSTATICALLY MONITORED. B) (1) DOUBLE-WALL 12,000-GAL. GASOLINE-FUEL UST WITH (1) 1.5 HP SUBMERGED TURBINE PUMP, INCLUDING DOUBLE-WALL CONTAINMENT SUMPS AND APPURTENANCES. TANK AND SUMPS SHALL BE HYDROSTATICALLY MONITORED. C) (2) TWO-HOSE TWO-PRODUCT FLEET-TYPE GASOLINE AND DIESEL DISPENSERS, INCLUDING (2) DOUBLE-WALL DISPENSER SUMPS AND APPURTENANCES WITH HYDROSTATIC MONITORING. D) (1) DOUBLE-WALL VENT-TRANSITION SUMP WITH HYDROSTATIC MONITORING. E) ALL TANKS SHALL BE PIPED TO VENT-TRANSITION SUMP, WITH VENT RISERS. F) ALL UNDERGROUND PRODUCT AND VENT PIPING SHALL BE DOUBLE WALLED RIGID FIBERGLASS REINFORCED PLASTIC AND BE SLOPED TOWARD THE TANK END OF THEIR RESPECTIVE RUNS. G) VEEDER ROOT LEAK-MONITORING CONSOLE TO SUPERVISE THE UNDERGROUND TANKS. CONSOLE SHALL MONITOR TANK LEVELS, LEAK SENSORS IN ALL SUMPS AND INTERSTITIAL HYDROSTATIC-LIQUID LEVELS IN ALL TANKS AND SUMPS. H) FUEL-MANAGEMENT TERMINALS AND SYSTEM, INCLUDING CONNECTIONS TO THE GASOLINE- DIESEL DISPENSERS AND CNG DISPENSERS. I) PACKAGED ELECTRICAL POWER-DISTRIBUTION PANEL FOR POWERING ALL FUEL PUMPS AND DISPENSERS, WITH HOOK-SWITCH ISOLATION, SWITCHED NEUTRAL AND UL LISTING. M L M L 2) THE FACILITY SHALL BE CONSTRUCTED AND TESTED IN CONFORMANCE WITH THE CURRENTLY ADOPTED EDITION OF THE FOLLOWING CODES AND STANDARDS AS SUPPLEMENTED, AMENDED, OR MODIFIED BY STATE OF WYOMING AND TOWN OF JACKSON: A) STATE OF WYOMING ADMINISTRATIVE CODE, TITLE 45. B) NFPA 30: FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE. C) NFPA 30A - CODE FOR MOTOR FUEL DISPENSING FACILITIES AND REPAIR GARAGES. D) NFPA 52 - VEHICULAR GASEOUS FUEL SYSTEMS CODE. E) NFPA 70 - INTERNATIONAL ELECTRICAL CODE (IEC). F) INTERNATIONAL FIRE CODE (IFC). K K 3) EXCEPT AS NOTED HEREIN, THE CONTRACTOR SHALL FURNISH ALL EQUIPMENT, AND PERFORM ALL INSTALLATION, TESTING, AND STARTUP NEEDED TO PROVIDE A COMPLETE AND FUNCTIONAL GASOLINE AND DIESEL FUELING FACILITY. J J 4) CONTRACTOR SHALL PROVIDE EQUIPMENT AS DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. OTHER EQUAL PRODUCTS MAY BE SUBSTITUTED ONLY WITH THE OWNER'S PRIOR APPROVAL, IN WRITING. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CHANGES TO THE APPROVED CONSTRUCTION DRAWINGS THAT RESULT FROM THE SUBSTITUTION OF EQUIPMENT SHOWN IN THE PLANS. 5) CONTRACTOR SHALL OBTAIN APPROVAL OF PRODUCT SUBMITTALS FOR MAJOR ITEMS OF EQUIPMENT, BEFORE ORDERING EQUIPMENT. FURNISH DATA SHEETS AND SHOP DRAWINGS, AS NEEDED FOR A CLEAR AND COMPLETE DESCRIPTION OF THE EQUIPMENT LISTED ON EQUIPMENT SCHEDULE SHEET. 6) CONTRACTOR SHALL OBTAIN ALL PERMITS NEEDED TO CONSTRUCT AND OPERATE THE PETROLEUM UST SYSTEMS, AS REQUIRED BY TOWN OF JACKSON AND STATE OF WAYOMING. I 7) THE FACILITY SHALL PASS THE FOLLOWING INSPECTIONS BY OWNER'S REPRESENTATIVE. CONTRACTOR SHALL SCHEDULE EACH INSPECTION AT LEAST FIVE WORKING DAYS BEFORE THE INSPECTION DATE. CONTRACTOR SHALL DOCUMENT TEST A) FIRST INSPECTION - WITNESS HOLIDAY OR SOAP TEST OF TANK BEFORE SETTING TANK, AND TO VERIFY THAT THE TANK EXCAVATION IS CLEAN AND HAS APPROPRIATE BACKFILL. B) SECOND INSPECTION - WITNESS PRESSURE TESTING OF THE INSTALLED PRIMARY PRODUCT, VENT AND VAPOR RECOVERY PIPING WHILE THE PIPING IS EXPOSED. C) THIRD INSPECTION - WITNESS PRESSURE TESTING OF SECONDARY CONTAINMENT PIPING, AND HYDROSTATIC (LAKE) TEST OF ALL TANK, TRANSITION, AND DISPENSER SUMPS. D) FOURTH INSPECTION - FINAL CONSTRUCTION INSPECTION, PERFORMED AFTER THE COMPLETION OF ALL WORK. E) UPON APPROVAL OF THE AUTHORITIES HAVING JURISDICTION AS OBTAINED BY THE CONTRACTOR, THE OWNER WILL ORDER AND ARRANGE FOR PRODUCT DELIVERIES. H 8) WORKERS INSTALLING THE FOLLOWING EQUIPMENT SHALL BE TRAINED AND CERTIFIED BY THE EQUIPMENT MANUFACTURER OR MANUFACTURER'S AUTHORIZED DISTRIBUTOR, BEFORE PERFORMING ANY APPLICABLE WORK FOR THIS PROJECT. EVIDENCE OF VALID CERTIFICATION SHALL BE PROVIDED TO THE OWNER, UPON REQUEST. WORK SHALL BE PERFORMED IN COMPLIANCE WITH THE MANUFACTURER'S WRITTEN INSTALLATION MANUAL(S): A) UNDERGROUND STORAGE TANK AND TANK SUMPS B) PIPING-TRANSITION AND DISPENSER CONTAINMENT SUMPS C) PRODUCT AND VENT PIPING D) PRODUCT PUMPS E) DIESEL DISPENSERS F) LEAK-MONITORING SYSTEM G) FUEL MANAGEMENT SYSTEM H) EQUIPMENT LONE VOLTAGE AND LOW VOLTAGE WIRING F G F 9) UNDERGROUND FIBERGLASS STORAGE TANKS SHALL BE BEDDED ON A MINIMUM THICKNESS OF 12" OF PEA GRAVEL CR #8 CRUSHED STONE FOR TANK BEDDING AND BACKFILL. ALL UNDERGROUND FIBERGLASS THICKNESS OF 7" PEA GRAVEL PER MANUFACTURER INSTRUCTIONS UNDER BURRY DEPTH OF NOT LESS CONFORM TO THE SPECIFICATIONS OF ASTM C-33, PARAGRAPH 9.1. SIZES 6. 67 OR 7. NO MORE THAN 5% (BY WEIGHT) OF THE BACKFILL MAY PASS THROUGH A #8 SIEVE. PEA GRAVEL MATERIAL IS TO BE WASHED, FREE-FLOWING, AND FREE OF ICE, SOIL AND DEBRIS. PEA GRAVEL SHALL ALSO COMPLY WITH THE REQUIREMENTS OF THE TANK MANUFACTURER'S INSTALLATION MANUAL. E E 10) ALL BALL VALVES SHALL BE LISTED UNDER UL 842 (VALVES FOR FLAMMABLE FLUIDS) AS BEING SUITABLE FOR FLAMMABLE LIQUID SHUT-OFF. 11) CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS PER MANUFACTURERS RESPECTIVE PUBLISHED INSTRUCTIONS FOR TANKS, SUMPS AND FUEL PIPING. GUIDANCE BY THE MANUFACTURER SHALL PREVAIL IF CONFLICTS OCCUR WITH INSTRUCTIONS RELATED TO OTHER PRODUCTS OR MATERIAL. CONTRACTOR SHALL ADHERE TO ALL COLD-WEATHER INSTALLATION INSTRUCTIONS AND LIMITATIONS AS INDICATED IN THE RESPECTIVE INSTALLATION MANUALS, INCLUDING FOR ANY FIELD WORK INVOLVING ADHESIVES OR BONDING MATERIALS. D D 12) CONTRACTOR SHALL FURNISH AND INSTALL ALL SAFETY SIGNAGE FOR PETROL FUELING EQUIPMENT AS REQUIRED BY NFPA 30A AND LOCAL AND STATE FIRE CODES. SIGNAGE SHALL BE CONSTRUCTED OF DURABLE NON-PLASTIC ALL-WEATHER MATERIAL, EVEN WHERE INSTALLED INDOORS, AND SHALL USE WHITE LETTERING ON DARK BACKGROUNDS EXCEPT WHERE CODE SPECIFIES OTHERWISE. NOT FOR CONSTRUCTION 13) ACCESS TO ALL SUMPS WITH FLOORS LOWER THAN 48" BELOW FINISHED GRADE REQUIRE CONFINED-SPACE ENTRY, AS DEFINED BY OSHA. C DESIGN DEVELOPMENT G JACKSON, WYOMING H TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY I C 14) PRIOR TO INTRODUCTION OF ANY PRODUCT TO ANY UST'S, OWNER SHALL COMPLETE ALL NOTICE AND COMPLIANCE FORMS FOR STORAGE AND USE OF THE INDICATED HAZARDOUS AND INDUSTRIAL MATERIALS, AND SUBMIT FORMS TO THE TOWN OF JACKSON FIRE DEPARTMENT. 15) OPENINGS FOR ALL MANWAYS AND ACCESS PORTS AT ALL TANK-TOP SLABS SHALL BE SLOPED UPWARD 1.0 INCH FROM SURROUNDING SLAB AND SHALL BF SLOPED AWAY FROM THE OPENINGS. B B 1 17) CONTRACTOR SHALL TRACK ANY CHANGES TO THE PLANS AND PREPARE FINAL AS-BUILT RECORD DRAWINGS AND PROVIDE TO THE OWNER PRIOR TO PROJECT CLOSE OUT. 4/8/13 Petrol Fueling Notes 19) WARRANT THAT ALL EQUIPMENT, MATERIALS AND WORKMANSHIP ARE FREE OF DEFECTS FOR 12 MONTHS, FOLLOWING ACCEPTANCE OF THE WORK BY THE OWNER. A A DRAWN BY: CHECKED BY: 18) PROVIDE (3) COPIES OF A BOUND MAINTENANCE MANUAL FOR ALL EQUIPMENT INSTALLED UNDER THE D-SERIES DRAWINGS. DESIGN DEVELOPMENT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DL001 1 N 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 N NOTE: 1. SEE DWG DL601 FOR CNG HEX CALL-OUT EQUIPMENT DESCRIPTIONS. M M L L K K 12 J 13 15 12 13 15 J 18 11 I 21 3 4 6 7 I 8 20 20 19 H H 3 9 2 G G 10 8 F F 3 10 E E 1 D D 14 NOT FOR CONSTRUCTION 17 C C B B 1 0 2 4 8 DESIGN DEVELOPMENT 4/8/13 Petrol Fuel Equipment Plan 16 A A NORTH DRAWN BY: CHECKED BY: DESIGN DEVELOPMENT 3 6 JACKSON, WYOMING 5 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DL101 1 2 3 4 N 5 6 7 8 9 10 11 12 13 14 15 16 17 18 N 2'-8 1/2" REF HIGH HOSE MAST (TYP 2) 3 IN-LINE BREAK-AWAY FITTING 'HUSKY' MODEL 3360 (TYP 2) 3 4 'GOODYEAR VEYANCE' FLEXSTEEL (TYP 2) DIESEL / GASOLINE DUAL HOSE DISPENSER NOZZLE MODEL OPW 11B-0400 (TYP 2) (BLACK SCRUFF GUARD FOR GASOLINE AND GREEN SCRUFF GUARD FOR DIESEL M 4" 3 M DIESEL DUAL HOSE DISPENSER 4 'GOODYEAR VEYANCE' FLEXSTEEL (TYP 2) 112" EMERGENCY SHUT-OFF VALVE (OPW 1OP-0152) 112" EMERGENCY SHUT-OFF VALVE (OPW 1OP-0152) L 2" 2" FRP PIPE SLEEVE FOR LEAK SENSOR MOUNTED TO SUMP FRAME 2" FRP x 1 12" NPT FLEX-ING FIRE FLEX CONNECTOR 3 5'-5" REF FOR DISPENSER DETAIL REFER TO DISPENSER SUMP DETAILS K NON-DISCRIMINATING DISPENSER SUMP SENSOR ('VEEDER-ROOT' P/N 794380-351) 2" PRIMARY FRP PRODUCT PIPE IN 3" CONTAINMENT PIPE J DIESEL D ISPENSE R PRODUC T LINE SENSOR CABLE RGS CONDUIT TO MONITORING CONSOL K L MINI HYDROSTATIC SUMP SENSOR ('VEEDER ROOT' P/N 794380-304) SEAL-OFF 1 TANK VENT LINE (TO TRANSITION SUMP) DIESEL DUAL HOSE DISPENSER GASOLINE / DIESEL DISPENSER (TYP 6) J LKG NORTH 1'-71 2" REF 12" MIN. PEA GRAVEL I 5'-33 8" REF I 6" 2" FRP X 1 12" NPT 'FLEX-ING' FIRE FLEX CONNECTOR 18"x 8"x 18' DEADMAN (TYP 2) H 2'-0" H 2" FRP x EZ-FIT ADAPTER FIBERGLASS DISPENSER SUMP ('S. BRAVO' B-9000) G 2" PRIMARY FRP PIPE IN 3" CONTAINMENT PIPE (FROM DISPENSERS TO UST) G LKG WEST F F E E D D DESIGN DEVELOPMENT GASOLINE / DIESEL DISPENSER JACKSON, WYOMING 4 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 3" BONDED SINGLE WALL FRP TESTABLE SUMP ENTRY FITTING ('SMITH FIBERCAST' P/N 012030-626-0) NOT FOR CONSTRUCTION C C B B 1 DESIGN DEVELOPMENT 4/8/13 A A DRAWN BY: CHECKED BY: Petrol Fuel Details 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DL511 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 N N SCHEDULE OF EQUIPMENT FOR PETROLEUM FUELING FACILITY 1 each M L K 3 UST Pump Sumps and Spill Containment Sumps 5 each 4 Spill Containment Manhole for Gasoline 1 assy 2-port 42" dia. H-20 manhole cover with roto-lock fasteners, 16" riser spacing, 5-gal spill containers with HDPE bellows and composite base, Phase 1 EVR approved. Furnish with 2-port manhole water shroud. OPW 6521EVR B-164042 5 Spill Containment Manhole for Diesel 1 assy 1-port 42" dia. H-20 manhole cover with roto-lock fasteners, 16" riser spacing, 5-gal spill containers with HDPE bellows and composite base. Furnish with 2-port manhole water shroud. OPW 6521EVR A-164042 6 Gasoline and Diesel Tight Fill Adapter 2 each 4" Tight-Fill Swivel Adapter, bronze, CARB-approved for Phase 1 EVR. OPW 61SALP-1020-EVR 7 Gasoline Vapor Adapter 1 each 4" Poppetted Swivel Vapor Adapter, CARB-approved for Phase 1 EVR. OPW 61VSA-1020-EVR 8 ULR and Diesel Overfill Prevention Valve and Drop Tube 2 assy 4" DIA, suitable for tank diameters up to 10', CARB-Approved for Phase 1 EVR. OPW 61SO-410C-EVR 1 assy 1.5-HP, 208V, 1-phase line-frequency motor, 2" discharge line, 4" packer manifold with pump inlet screen, and integral check valve suitable for Veeder Root Pressurized Line Leak Detector. Suitable for blends of up to 100% ethanol or 20% TAME in gasoline. FE Petro STP-AGKRV-150-A or Red Jacket P150U1 2 assy 2-HP, 208V, 1-phase line-frequency motor, 2" discharge line, 4" packer manifold with pump inlet screen, and integral check valve suitable for Veeder Root Pressurized Line Leak Detector. Suitable for blends of up to 100% ethanol or 20% TAME in gasoline. FE Petro STP-AGKRV-200-A or Red Jacket P200U1 3 each Shall be a standard product of the product pump manufacturer, and protect the pump against overcurrent, excessive run time, and run-dry. FE Petro STP SCI or Red Jacket IQ Controller Dresser-Wayne Select 3/G7203D/28GJ/J ULR Gasoline Product Pump Diesel Product Pump Submerged-Turbine Pump Controller Containment Solutions 10-12DWHG Containment Solutions Hydroguard 12 2-Hose 2-Product Gasoline and Diesel Dispenser 2 each Remote 2-hose 2-product enhanced capacity dispenser, high-hose mast, electronic registers, illuminated display, fuel management system interface card, galvanized steel frame, island oriented, explosion-proof junction box, and white powder coat panels. Provide 1.5" inlet, 20 GPM per diesel nozzle, 10 GPM per gasoline nozzle. Controls shall be configured per ADA requirements, with all user-interface elements a maximum of 54" above the driveway surface. 13 Dispenser Sump 2 each FRP double-wall dispenser sump with hydrostatic monitoring, offset frame for electrical conduit risers, UL-listed emergency valve frame, and epoxy-coated steel mid-frame. S. Bravo Systems B9000 B-EO S. BRAVO B-600 with RS500 Vent Rack 14 Transition Sump 1 each Double wall FRP transition sump with two 2" pipe riser vent, containment sump for piping transition from underground plastic pipe 2" in 3" secondary containment. AB 2481 compliant hydrostatically monitored, with watertight cover and integral galvanized steel walkover manhole cover. Furnish with transition fittings. 15 Emergency Shut-Off Valve (product line shear valve) 4 each Equip with 1.5" NPT connections, female top connection, double poppet and boss-mount. OPW 10 PLUS 10P-152 16 Underground Product and Vent 2" Primary in 3" Secondary Pipe Coaxial double-wall filament-wound fiberglass-reinforced plastic (FRP) with 2" primary pipe, per the Drawings. Pipe shall be listed under UL 971 (July 2005). Primary pipe fittings shall be filament-wound FRP. Containment shall be continuously vacuum monitored. Smith Fibercast Red Thread IIA or Ameron 3000/L 17 Pressure/Vacuum vent valve Valve shall remain closed at tank pressures between 3" WC and -8" WC. Husky 5885 I 18 Leak Monitoring System 19 Overfill Alarm 20 F M 1 each 11 G Containment Solutions 10-20DWHG 12,000 gal. UST for ULR Gasoline 10 H FRP, 10' Dia., double-wall, UL 1316, with hydrostatic monitoring, brine-filled interstice & monitoring well. Furnish tank with two 48" attached hydrostatic collars at the manway for two pumps, aluminum ladder, 42" attached hydrostatic collar around the 4" tank wall service fittings, and FRP anchor straps & deadmen by the tank manufacturer. FRP, 10' Dia., double-wall, UL 1316, with hydrostatic monitoring, brine-filled interstice & monitoring well. Furnish tank with two 48" attached hydrostatic collars at the manway for two pumps, aluminum ladder, 42" attached hydrostatic collar around the 4" tank wall service fittings, and FRP anchor straps & deadmen by the tank manufacturer. AB 2481-compliant, double-wall, liquid-monitored fiberglass sump, straight-sided, 48" dia. (3 pump sumps) and 42" dia. (2 fill sumps). Provide with sealed FRP cover for manway sump. To be warranted and certified to be used for E85 and B20 as well as gasoline and diesel. 2 9 J MFR & MODEL SPECIFICATION 21 Fuel-Management Terminal Petroleum Power-Distribution and Control Panel ? ft. 2 each Piping, UST, and sump monitoring system using pressurized line leak detectors, non-discriminating tank sump sensors, dispenser sump sensors, and supervision of monitoring fluid levels, and tank level probes. Monitoring panel shall perform 0.05 gal/h precision line leak test on product pipe. System shall 1 system automatically reconcile tank level versus volume dispensed, and generate reconciliation reports monthly. System shall immediately page the responsible technician by telephone upon detection of overfill, leak, or loss of containment. Include modules for PLLD leak detection, and communication via POTS and IP connections. Provides audible and visible alarms when tank level exceeds 90%. Furnish with Acknowledgement Switch. 1 assy Alarm shall be controlled by a relay contact in the Monitoring Console. L K J I H Veeder Root TLS-350R Veeder Root Overfill Alarm 2 each Fuel island terminal (FIT) on each island shall authorize and record fueling transactions for all connected CNG and petrol dispensers, via key pad and mag-card entry, including fleet-fuel cards. Wire master FIT to local IP switch and telephone board for IP and POTS connections. Controls shall be installed per ADA requirements and shall be a maximum of 54" above the driveway surface. Provide local receipt printer with terminal located on island with CNG dispenser. Provide PC-based remote-host software for tracking & managing transactions, including installation, training and 12-month phone-based technical support. Gasboy Islander Plus 1 each UL-listed assembly equipped with 70A main circuit breaker and branch circuit breakers; pump motor starters, contactors for pump and dispenser power circuits to automatically disconnect power emergency shutdown; includes switched neutral and 100kA/phase TVSS protecting all power feeder circuits. Designate as panel 'PP1'. Include ESD contactor for relay interface with 120V CNG ESD system so that any ESD opens and activates ESD function on petrol and CNG systems. Carolina Products Petro Power Panel I G F Schedule Notes: E 1 See drawing DL101 for plan location of keyed equipment. 2 The list of equipment given here is partial. Contractor shall furnish all equipment, Labor, conduit, wire, piping, material and testing services to deliver a complete functional petroleum fueling system required by plans, drawings, and specifications, and as approved by the owner. Refer to the specification sections 28 34 01, 23 13 23, and 23 12 18 for additional requirements. E D D DESIGN DEVELOPMENT 20,000 gal. UST for Diesel QTY. REQ'D JACKSON, WYOMING 1 ITEM TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY KEY NO. NOT FOR CONSTRUCTION C C B B 1 DESIGN DEVELOPMENT 4/8/13 A A DRAWN BY: CHECKED BY: Petrol Equipment Schedule 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DL601 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 N N DUAL HOSE GASOLINE / DIESEL DISPENSER D-1 10 GPM / 20 GPM DUAL HOSE GASOLINE / DIESEL DISPENSER D-1 10 GPM / 20 GPM M M 2" PRESSURE VACUUM CAP L L 1 2" EMERGENCY SHUT-OFF VALVE 2" EMERGENCY SHUT-OFF VALVE 2" EMERGENCY SHUT-OFF VALVE 2" GALVINIZED SCH 40 CS PIPE (ABOVE GROUND) 2" FLEX CONNECTOR (FLEX-ING FIRE FLEX - FRP) L TO MONITOR PANEL J WATER TIGHT CONTAINMENT SUMP ON ATTACHED COLLAR (TYP 3) SLOPE 1/8" PER FT. TO MONITOR PANEL GASOLINE PIPE FOR CONT. SEE FD6.20 K TO MONITOR PANEL L TO MONITOR PANEL 2" FLEX CONNECTOR (FLEX-ING FIRE FLEX - FRP) J SLOPE - 1/8" PER FT. SLOPE - 1/8" PER FT. L 2" EMERGENCY SHUT-OFF VALVE 2" FLEX CONNECTOR (FLEX-ING FIRE FLEX - FRP) 2" FLEX CONNECTOR (FLEX-ING FIRE FLEX - FRP) SLOPE - 1/8" PER FT. L 4" NPS PLUG (TEST PORT) K SLOPE - 1/8" PER FT. TO MONITOR PANEL L TO MONITOR PANEL GASOLINE PIPE FOR CONT. SEE FD6.20 L DISPENSER SUMP DISPENSER SUMP STAGE 1 EVR 4" SWIVEL FILL ADAPTER PIPE TRANSITION SUMP I FLEX-ING FIBER-FLEX BONDED FRP ADAPTER FLEX-ING FIBER-FLEX BONDED FRP ADAPTER I TO MONITOR PANEL 2" FRP VENT LINE IN 3" FRP CONTAINMENT PIPE L L TO MONITOR PANEL L 3" FRP PRODUCT PIPE IN 4" FRP CONTAINMENT PIPE SLOPE - 1/8" PER FT. H H L TO MON. PANEL L MONITORING FLUID RESERVOIR 4" x 3" EXTRACTOR TEE 20,000 GALLON UST DIESEL GASOLINE G G F PRESSURIZED LINE LEAK DETECTOR (TO MONITOR PANEL) 2 HP SUBMERSIBLE TURBINE PUMP PRESSURIZED LINE LEAK DETECTOR (TO MONITOR PANEL) TO MONITOR PANEL MAGNETOSTRICTIVE TANK LEVEL PROBE TO MONITOR PANEL F 2" SWING CHECK VALVE W/ 50 PSI RELIEF "MORRISON BROTHERS" (TYP 2 PLCS) L L WATER TIGHT CONTAINMENT SUMP 2" PUMP DISCHARGE 2 HP SUBMERGED PUMP E 2" BALL VALVE (TYP 2 PLCS) 2 HP SUBMERGED PUMP 2" PUMP DISCHARGE PRIMARY PIPE SYMBOLS AND LEGEND MANUAL BALL VALVE D L SOLID STATE LEAK SENSOR (TYP AT EACH COLLAR) L AUTOMATIC TANK GAUGE LEAK OR LEVEL SENSOR L E SECONDARY CONTAINMENT PIPE SECONDARY CONTAINMENT PIPE D INNER TANK WALL 3-WAY VALVE CHECK VALVE FLEX-ING FIBER FLEX FRP ADAPTER FLEX-ING FIBER FLEX FRP ADAPTER FLEX CONNECTOR (FLEX-ING FIRE FLEX FRP) FLEX CONNECTOR (FLEX-ING FIRE FLEX FRP) NOT FOR CONSTRUCTION INSTR. SIGNAL C DESIGN DEVELOPMENT 2 HP SUBMERSIBLE TURBINE PUMP JACKSON, WYOMING 4" STAGE 1 EVR OVERFILL PREVENTION VALVE AND DROP TUBE TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 3" BALL FLOAT VALVE C BALL FLOAT VALVE DIESEL PUMP SUMP DETAIL NOTE: 1. EQUIPMENT SHOWN ON THIS DRAWING MAY HAVE A DIFFERENT APPEARANCE AND CONFIGURATION THAN THE ACTUAL EQUIPMENT SPECIFIED. B B 1 DESIGN DEVELOPMENT 4/8/13 A A DRAWN BY: CHECKED BY: Diesel Flow Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DL611 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 N N DUAL HOSE GASOLINE / DIESEL DISPENSER D-1 10 GPM / 20 GPM M M 2" PRESSURE VACUUM CAP L L 1 4" NPS PLUG (TEST PORT) K 2" EMERGENCY SHUT-OFF VALVE 2" GALVINIZED SCH 40 CS PIPE (ABOVE GROUND) TO MONITOR PANEL I 2" FRP VENT LINE IN 3" FRP CONTAINMENT PIPE W/ VACUUM MONITORING L TO MONITOR PANEL I 2" FRP PRODUCT PIPE IN 3" FRP CONTAINMENT PIPE W/ VACUUM MONITORING TO MONITOR PANEL SLOPE - 1/4" PER FT. TO MON. PANEL 4" x 3" EXTRACTOR TEE H PRESSURIZED LINE LEAK DETECTOR PUMP SYPHON (VACUUM SOURCE) TO MONITOR PANEL 12,000 GALLON UST GASOLINE G TO MONITOR PANEL TO MONITOR PANEL TO MONITOR PANEL L L L DIESEL PIPE FOR CONT. SEE FD6.10 FLEX-ING FIBER-FLEX BONDED FRP ADAPTER H G L 3" BALL FLOAT VALVE 4" STAGE 1 EVR OVERFILL PREVENTION VALVE AND DROP TUBE WATER TIGHT CONTAINMENT SUMP 1.5 HP SUBMERSIBLE TURBINE PUMP F 1.5 HP SUBMERGED PUMP F MAGNETOSTRICTIVE TANK LEVEL PROBE 2" SECONDARY CONTAINMENT PIPE 2" PUMP DISCHARGE PRIMARY PIPE E E AUTOMATIC TANK GAUGE FLEX-ING FIBER FLEX FRP ADAPTER FLEX CONNECTOR (FLEX-ING FIRE FLEX FRP) L L SOLID STATE LEAK SENSOR (TYP AT EACH COLLAR) D D DESIGN DEVELOPMENT MONITORING FLUID RESERVOIR J DISPENSER SUMP WATER TIGHT CONTAINMENT SUMP ON ATTACHED COLLAR (TYP 2) TO MONITOR PANEL TO MONITOR PANEL L PRESSURIZED LINE LEAK DETECTOR (TO MONITOR PANEL) L PIPE TRANSITION SUMP 2" FLEX CONNECTOR (FLEX-ING FIRE FLEX - FRP) TO DUAL HOSE GASOLINE / DIESEL DISPENSER D-2 (TYP) L TO MONITOR PANEL 2" FLEX CONNECTOR (FLEX-ING FIRE FLEX - FRP) PHASE 1 EVR 4" SWIVEL FILL ADAPTER SLOPE - 1/4" PER FT. 2" EMERGENCY SHUT-OFF VALVE JACKSON, WYOMING TO MONITOR PANEL PHASE 1 EVR 4" POPPETED VAPOR ADAPTER L J L TO MONITOR PANEL TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY K INNER TANK WALL VT NOT FOR CONSTRUCTION PUMP SUMP DETAIL C 1. C EQUIPMENT SHOWN ON THIS DRAWING MAY HAVE A DIFFERENT APPEARANCE AND CONFIGURATION THAN THE ACTUAL EQUIPMENT SPECIFIED. B B 1 DESIGN DEVELOPMENT 4/8/13 A A DRAWN BY: CHECKED BY: Gasoline Flow Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DL612 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 N N NOTES: 1. ALL CONTROL AND FEEDER CIRCUITS ARE 120V, UNLESS NOTED OTHERWISE. 2. ALL LINE VOLTAGE CONDUCTORS AND GROUND WIRES SHALL BE 12 AWG COPPER W/ THNN INSULATION, UNLESS NOTED OTHERWISE. M M 3. ACTUATING ANY EMERGENCY STOP BUTTON SHALL DISCONNECT ALL FEEDERS CONTROLLED BY THE RELAY PANEL. EACH FEEDER CONTROLLED BY THE RELAY PANEL SHALL HAVE A DISCONNECTING LOCK, CONTROLLED BY A KEY. 4. ESD ACTIVATION SHALL NOT DE-ENERGIZE MONITORING CONSOLE OR OVERFILL ALARM. L E-STOP BUTTON 5. RUN TWO DIESEL PUMPS IN ALTERNATING CONFIGURATION. IN CASE ONE PUMP IS NOT RESPONDING, RUN THE OTHER PUMP. E-STOP BUTTON 6. SEE DWG. DL-601 FOR LISTING OF HEX-KEYED EQUIPMENT. SEE DRAWING DL-101 FOR PLAN LOCATION OF HEX-KEYED EQUIPMENT. FUEL MGMT TERMINAL 1 TO CNG SKID CONTROL CNG POWER FEEDER DISPENSER J-BOX TO CNG POWER PANEL VALVE CONTROL 1 CNG AUTHORIZATION DISPENSER 1 AUTHORIZATION VALVE CONTROL 2 IN USE SIGNAL 2 DISPENSER 1 DSL CNG DISPENSER 3 J 120V DISPENSER 1 POWER FEEDER DISPENSER J-BOX IN USE SIGNAL 1 20 EMERGENCY STOP POWER CONTACTOR 120V FUEL MANAGEMENT TERMINAL POWER FEEDER K 12 7. PROVIDE GROUND WIRING FOR EACH NOZZLE. GROUND WIRES CONDUITS SHALL BE SEPARATE FROM POWER LINE CONDUITS. J DISPENSER SUMP SYMBOL: CONDUIT SEAL CNG POWER FEEDER DISPENSER J-BOX TO CNG POWER PANEL IN USE SIGNAL 3 CNG AUTHORIZATION 120V DISPENSER 2 POWER FEEDER DISPENSER J-BOX DISPENSER 2 AUTHORIZATION VALVE CONTROL 4 IN USE SIGNAL 4 DISPENSER 2 DSL H CNG DISPENSER 4 20 12 H DISPENSER HOOK ISOLATION TO CNG SKID CONTROL VALVE CONTROL 3 I TVSS 120V FUEL MANAGEMENT TERMINAL POWER FEEDER FUEL MGMT TERMINAL 2 K 8. SEE SEPARATE LOW VOLTAGE BLOCK WIRING DIAGRAM DWG# DL-702. DISPENSER ISLAND #1 I L DISPENSER SUMP DISPENSER ISLAND #2 OVER-FILL ALARM G G 120V POWER FEEDER (SEE NOTE 4) ULR AUTHORIZATION VEEDER ROOT TLS-350-R MONITORING CONSOLE D1 DIESEL AUTHORIZATION COMMUNICATION (LAN & PHONE BOARD) INTRINSICALLY SAFE 120 V D2 DIESEL AUTHORIZATION E ULR PUMP RUN F E POWER FEEDER PHONE BOARD POTS 208V DISTRIBUTION PANEL LAN I/P ETHERNET D1 DIESEL PUMP RUN D2 DIESEL PUMP RUN GASOLINE PUMP 1 CONTROLLER 10 AWG THHN IN CONDUIT D DSL PUMP 1 CONTROLLER 10 AWG THHN IN CONDUIT DSL PUMP 2 CONTROLLER 10 AWG THHN IN CONDUIT C 12,000 GAL UST GASOLINE 2 20,000 GAL UST DIESEL D DESIGN DEVELOPMENT POWER FEEDER POWER, CONTROL & ESD PANEL "PP1" 120V OVERFILL ALARM 18 F 21 JACKSON, WYOMING OVERFILL ALARM RELAY SIGNAL SEE NOTE 4 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY ACKNOWLEDGE RESET 19 NOT FOR CONSTRUCTION C 1 B B 1 DESIGN DEVELOPMENT 4/8/13 A A DRAWN BY: CHECKED BY: Line Voltage Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DL711 ST OST SAN NOTE: ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE DIMENSIONS. DOMESTIC COLD WATER PIPING DIRECTION OF FLOW IN PIPING DOMESTIC HOT WATER PIPING CONTROL VALVE DOMESTIC HOT WATER RECIRC. PIPING THREE WAY CONTROL VALVE INSULATED FLEXIBLE DUCT (MAXIMUM 4'-0" LONG) 180°F DOMESTIC HOT WATER PIPING GATE (SHUT OFF) VALVE BRANCH DUCT WITH 45° TAP AND MANUAL VCD 180°F DOMESTIC HOT WATER RECIRC. PIPING GLOBE VALVE STORM DRAIN PIPING OVERFLOW STORM DRAIN PIPING LINEAR SLOT DIFFUSER BRANCH DUCT WITH CONICAL FITTING AND MANUAL VCD BALANCING VALVE S SOLENOID VALVE BRANCH DUCT WITH 45° TAP AND MANUAL VOLUME CONTROL DAMPER SANITARY PIPING THERMOSTATIC MIXING VALVE SS SUB-SOIL DRAIN PIPING BALANCING VALVE WITH PRESSURE PORTS V ELBOW WITH TURNING VANES VENT PIPING TRIPLE DUTY VALVE WITH PRESSURE PORTS AW ACID WASTE PIPING BELOW FLOOR BRANCH DUCT WITH BELL MOUTH FITTING AND MANUAL VOLUME CONTROL DAMPER STRAINER AV ACID VENT PIPING STRAINER WITH BLOWOFF G CA GO NATURAL GAS PIPING s COMPRESSED AIR PIPING RELIEF/SAFETY VALVE RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN PRESSURE REDUCING VALVE GAS OIL WASTE PIPING BELOW FLOOR HYDRONIC PIPING RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP V SUPPLY AIR DUCT UP VACUUM BREAKER SUPPLY AIR DUCT DOWN GAS COCK HWS EQUIPMENT WITH FLEXIBLE DUCT CONNECTION HEATING HOT WATER SUPPLY PIPING SIGHT GLASS HWR D-1 10x10 250 HEATING HOT WATER RETURN PIPING BALL VALVE CD CONDENSATE DRAIN PIPING TYPE, NECK SIZE, CFM AT SUPPLY DIFFUSER OR REGISTER HOSE GATE VALVE RG-1 10x10 250 RUNNING TRAP TYPE, THROAT SIZE, CFM AT RETURN GRILLE OR REGISTER THERMOSTATIC TRAP ER-1 10x10 250 F&T TRAP TYPE, SIZE AT EXHAUST GRILLE OR REGISTER, CFM AT EXHAUST GRILLE OR REGISTER PRESSURE GAUGE MANUAL VOLUME CONTROL DAMPER THERMOMETER UNION SQUARE TO ROUND TRANSITION FLANGE CONNECTION T THERMOSTAT PIPING ELBOW UP CO CARBON MONOXIDE DETECTOR PIPING ELBOW DOWN DDC DN DX DIRECT DIGITAL CONTROL DOWN DIRECT EXPANSION EAT EC EDB EF EPO ETR EWB EWC ENTERING AIR TEMPERATURE ELECTRICAL CONTRACTOR ENTERING DRY BULB EXHAUST FAN EMERGENCY POWER OFF EXISTING TO REMAIN ENTERING WET BULB ELECTRIC WATER COOLER FACP FBO FC FCU FCO FD FF FHC FL FLR FPC FSD FIRE ALARM CONTROL PANEL FURNISHED BY OTHERS FLOOR CLEANOUT FAN COIL UNIT FLOOR CLEANOUT FIRE DAMPER, FLOOR DRAIN FINISHED FLOOR FIRE HOSE CABINET FLOW LINE FLOOR FIRE PROTECTION CONTRACTOR FIRE/SMOKE DAMPER GC GCO GND GPM GENERAL CONTRACTOR GRADE CLEANOUT GROUND GALLONS PER MINUTE HOSE BIBB HEAD, HUB DRAIN HAND OFF AUTOMATIC HORSEPOWER, HEAT PUMP HUMIDISTAT HORIZONTAL SINGLE ZONE BLOW THROUGH HORIZONTAL SINGLE ZONE DRAW THROUGH HEATING HEATER HEATING AND VENTILATING UNIT HEATING WATER RETURN HEATING WATER SUPPLY PIPING TEE DOWN WITH SHUT OFF VALVE BD BACKDRAFT DAMPER DESIGNATION IE IN.WC INVERT ELEVATION INCHES OF WATER COLUMN LAT LDB LF LP LRA LWB LWT LEAVING AIR TEMPERATURE LEAVING DRY BULB LINEAR FEET LOW PRESSURE LOCKED ROTOR AMPS LEAVING WET BULB LEAVING WATER TEMPERATURE MBH MC MCA MCC MD MDP MFR MG MH MTD MU MUAF 1000 BTU PER HOUR MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MOTORIZED DAMPER MAIN DISTRIBUTION PANEL MANUFACTURER MOTOR GENERATOR MANHOLE MOUNTED MAKE UP MAKE UP AIR FAN N/A NC NIC NO NOT APPLICABLE NOISE CRITERIA, NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN OA OC OUTSIDE AIR ON CENTERPROOF PIPING ELBOW DOWN WITH SHUT OFF VALVE FSD COMBINATION FIRE/SMOKE DAMPER DESIGNATION SD SMOKE DAMPER DESIGNATION PIPING TEE 12/6 RECTANGULAR DUCT (1ST FIG. SIDE SHOWN) 90° ELBOW 12" ROUND DUCT (1ST FIG. = DIAMETER) PIPING CAP TRANSITION IN DUCT SIZE VAV-1 300 GAUGE COCK VARIABLE AIR VOLUME BOX - TYPE, CFM WATER HAMMER ARRESTOR PIPING REDUCER PIPING INCREASER PRESSURE REGULATING VALVE FLEXIBLE CONNECTOR VENT THRU ROOF 3"FS-1 FLOOR SINK, SIZE AND TYPE 3"FD-1 FLOOR DRAIN, SIZE AND TYPE SHOWER DRAIN, SIZE AND TYPE ROOF DRAIN, SIZE AND TYPE HOSE BIBB / WALL HYDRANT MANUAL AIR VENT CO WCO COMPRESSED AIR COOLING TOWER CONDENSATE DRAIN (COLD) CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CLEANOUT CONDENSATE RETURN COMPUTER ROOM AIR CONDITIONING UNIT COMPUTER ROOM CONDENSING UNIT CONDENSING UNIT COLD WATER CHILLED WATER RETURN CHILLED WATER SUPPLY MOTORIZED DAMPER DESIGNATION FIRE DAMPER DESIGNATION PIPING ELBOW UP WITH SHUT OFF VALVE HB WH CA CT CD CDR CDS CFM CO CR CRAC CRCU CU CW CWR CWS M FD PIPING TEE DOWN 3"RD-1 BACKDRAFT DAMPER, BLOWDOWN BELOW FINISHED FLOOR BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STRUCTURE BRITISH THERMAL UNIT PIPING TEE UP WITH SHUT OFF VALVE GAS DETECTOR PIPING TEE UP 3"SHD-1 BD BFF BOD BOP BOS BTU HB HD HOA HP HSTAT HSZBT HSZDT HTG HTR HVU HWR HWS G VTR AIR CONDITIONING AIR COOLED CHILLER AIR COOLED CONDENSING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT FLOOR CLEANOUT GCO GRADE CLEANOUT PIPE ANCHOR / ROOF PIPING SUPPORT EXPANSION JOINT PIPE GUIDE PRIMARY CHILLED WATER RETURN PRIMARY CHILLED WATER SUPPLY PUMPED CONDENSATE RETURN PHASE PRIMARY HEATING WATER RETURN PRIMARY HEATING WATER SUPPLY POST INDICATOR VALVE PRESSURE REDUCING VALVE 1. REFER TO PLANS FOR ADDITIONAL NOTES. 2. THE PLANS ARE, TO A GREAT EXTENT, DIAGRAMMATIC IN NATURE. DRAWING SCALES SHOULD BE VERIFIED FROM DIMENSIONS ON ARCH. PLANS. THE INFORMATION PRESENTED IS AS EXACT AS COULD BE SECURED. THE CONTRACTOR SHALL OBTAIN EXACT LOCATION, MEASUREMENTS LEVELS, ETC. AT THE SITE AND SHALL SATISFACTORILY ADAPT THE WORK TO THE ACTUAL CONDITIONS AT THE PROJECT SITE. QTY QUANTITY 3. RA RCP RD REV RH RHG RL RLA RPM RS RTU RETURN AIR REINFORCED CONCRETE PIPE ROOF DRAIN REVISION RELATIVE HUMIDITY REFRIGERANT HOT GAS REFRIGERANT LIQUID RUNNING LOAD AMPS REVOLUTIONS PER MINUTE REFRIGERANT SUCTION ROOF TOP UNIT CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO SUBMITTING A BID TO COVER THE CONDITIONS AT THE SITE INFORMING THEMSELVES OF ALL DETAILS. SA SCHR SCHS SD SF SHWR SHWS SOV SP SS ST STC STM SUPPLY AIR SECONDARY CHILLED WATER RETURN SECONDARY CHILLED WATER SUPPLY SMOKE DETECTOR SQUARE FEET SECONDARY HEATING WATER RETURN SECONDARY HEATING WATER SUPPLY SHUT-OFF VALVE STATIC PRESSURE STAINLESS STEEL, SANITARY SEWER SOUND TRAP, STEAM TRAP, STORM LINE SOUND TRANSMISSION CLASS STEAM TA TDH TSTAT TWU TRANSFER AIR TOTAL DYNAMIC HEAD THERMOSTAT THROUGH WALL AIR CONDITIONING UNIT U/F U/G UH U/S UL UNO UPS UNDERFLOOR UNDERGROUND UNIT HEATER UNDERSLAB UNDERWRITERS LABORATORIES, INC. UNLESS NOTED OTHERWISE UNINTERRUPTIBLE POWER SUPPLY VAC VAV VCP VD VSZBT VSZDT VTR VACUUM VARIABLE AIR VOLUME VITRIFIED CLAY PIPE VOLUME DAMPER VERTICAL SINGLE ZONE BLOW THROUGH VERTICAL SINGLE ZONE DRAW THROUGH VENT THROUGH ROOF 4. 5. 6. WITH WITHOUT WET BULB WALL CLEANOUT WATER COLUMN WATER GAGE WATER PRESSURE DROP WEATHERPROOF WATERTIGHT, WEIGHT XFMR XP TRANSFORMER EXPLOSION PROOF THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL ENGINEERING REQUIREMENTS, THE OWNER'S DESIGN CRITERIA, UTILITY COMPANY REQUIREMENTS, APPLICABLE INDUSTRY STANDARDS OF GOOD PRACTICE AND SAFETY AND THE MANUFACTURER'S STRICTEST RECOMMENDATIONS FOR EQUIPMENT AND PRODUCT APPLICATION AND INSTALLATION. MANUFACTURERS' NAMES ON WHICH THIS SPECIFICATION IS BASED INDICATE THE MINIMUM QUALITY OF PRODUCT REQUIRED BY ARCHITECT/ENGINEER. SUBSTITUTIONS MAY BE MADE TO THOSE SPECIFIED IF DEEMED EQUIVALENT BY THE ARCHITECT/ENGINEER DURING SUBMITTAL REVIEW. MISCELLANEOUS 1 M1 SECTION CUT, UPPER NUMBER INDICATED DRAWING NUMBER LOWER NUMBER INDICATES SHEET NUMBER 1 M1 DETAIL REFERENCE: UPPER NUMBER INDICATES DETAIL NUMBER LOWER NUMBER INDICATES SHEET NUMBER 1 NOTE REFERENCE SYMBOL 28. PROVIDE ALL 90 DEGREE SQUARE ELBOWS WITH DOUBLE RADIUS TURNING VANES UNLESS OTHERWISE INDICATED. ELBOWS IN DISHWASHER, KITCHEN, AND LAUNDRY EXHAUST SHALL BE UNVANED SMOOTH RADIUS CONSTRUCTION WITH A RADIUS EQUAL TO 1.5 TIMES THE WIDTH OF THE DUCT. PROVIDE ACCESS DOORS UPSTREAM OF ALL ELBOWS WITH TURNING VANES.BRANCHES IN WHICH BRANCH PIPING SERVES TWO OR MORE FIXTURES. 29. FINNED-TUBE RADIATION ENCLOSURES SHALL BE WALL TO WALL UNLESS OTHERWISE INDICATED. 30. ALL RETURN AIR TRANSFER DUCTS SHALL BE ACOUSTICALLY TREATED WITH 1" DUCT LINER. 31. PROVIDE MIN. OF 5'-0" OF DUCT FROM ROOM TERMINAL UNITS TO FIRST DIFFUSER TAKE-OFFS. 32. MAXIMUM FLEX LENGTH FOR CONNECTION TO BOX SHALL BE 18" AND TO DIFFUSERS SHALL BE 48". ALL CONNECTIONS TO CONSTANT VOLUME BOXES SHALL HAVE TRANSITIONS AS REQUIRED FROM SUPPLY DUCT TO BOX. 33. CONTRACTOR SHALL COORDINATE LOCATION OF ALL DIFFUSERS AND GRILLES WITH STRUCTURAL, ELECTRICAL, AND ARCHITECTURAL REFLECTED CEILING PLANS. 34. PROVIDE SIZES AND NUMBER OF REFRIGERANT LINES ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. 35. 7. 8. W W/O WB WCO WC WG WPD WP WT ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES, LAWS, ACTS AND ORDINANCES, AND ALL AUTHORITIES HAVING JURISDICTION. 9. 36. SUPPORTS - EQUIPMENT, PIPING, DUCTWORK OR ANY OTHER ACCESSORY SHALL NOT BE SUPPORTED FROM OTHER PIPING, DUCTWORK, METAL ROOF DECK, LATERAL BRACING BRIDGING, OR CONDUIT. ITEMS SHALL ONLY BE SUPPORTED FROM BUILDING STRUCTURE. BEFORE INSTALLATION, EQUIPMENT CONTRACTOR SHALL VERIFY THAT COILS CAN BE REMOVED WITHOUT INTERFERENCE. CONTRACTOR SHALL PROVIDE ADEQUATE ACCESS AND COIL REMOVAL SPACE FOR ALL EQUIPMENT. 37. ACCESS PANELS ARE REQUIRED (MIN. 18"X18") FOR ACCESS TO EVERY VALVE, DAMPER, AIR TERMINAL UNIT, AND CONTROL SENSOR IF NOT OTHERWISE ACCESSIBLE. ACCESS PANEL SHALL BE APPROVED BY ARCHITECT/ENGINEER. 38. ALL PIPING BRANCH TAKE-OFFS TO REHEAT COIL, CABINET HEATERS, AND UNIT HEATERS SHALL BE INSTALLED WITH A MINIMUM OF FIVE (5) PIPE DIRECTION CHANGES. 39. ALL HWS/HWR TAKE-OFFS TO REHEAT COILS TO BE A MINIMUM OF 3/4" PIPE SIZE. 40. SMOKE DETECTORS SHALL BE FURNISHED AND WIRED BY THE ELECTRICAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR MOUNTING THE SMOKE DETECTOR IN DUCTWORK AS SHOWN ON THE ELECTRICAL DRAWINGS AND IN ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS. 41. PROVIDE SHUTOFF VALVES IN ALL DOMESTIC WATER PIPING SYSTEM BRANCHES IN WHICH BRANCH PIPING SERVES TWO OR MORE FIXTURES. COORDINATE EXACT LOCATION OF ALL DUCTWORK, AIR TERMINAL UNITS, PIPING, ETC., WITH STRUCTURAL, ARCHITECTURAL, ELECTRICAL, AND OTHER MECHANICAL SYSTEMS. 10. WHERE MOUNTING HEIGHTS ARE NOT DETAILED OR DIMENSIONED, INSTALL MECHANICAL SERVICES AND OVERHEAD EQUIPMENT TO PROVIDE THE MAXIMUM HEADROOM POSSIBLE. 11. ALL DUCTWORK, PIPING, AND TEMPERATURE CONTROL CONDUIT TO VIBRATING EQUIPMENT SHALL HAVE FLEXIBLE CONNECTORS. 12. IF ASBESTOS IS ENCOUNTERED OR SUSPECTED, HALT WORK IMMEDIATELY IN THESE AREAS AND NOTIFY CONTRACTING OFFICERS REPRESENTATIVE BEFORE PROCEEDING. DO NOT DAMAGE OR DISTURB SUSPECTED ASBESTOS CONTAINING MATERIAL. COORDINATE ALL REMOVAL WITH THE CONSTRUCTION MANAGER AND OWNER. 13. COORDINATE ALL ROOF AND CHASE PENETRATIONS WITH STRUCTURAL DRAWINGS AND ROOF INSTALLER. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com MECHANICAL CONTRACTOR IS COMPLETELY RESPONSIBLE FOR PROVIDING ALL PRESSURE AND/OR TEMPERATURE TAPS IN PIPING AS REQUIRED FOR PROPER BALANCING OF ALL SYSTEMS. RECORD DRAWINGS - PREPARE AND SUBMIT TO THE OWNER RECORD DRAWINGS INDICATING THE EXACT LOCATION OF ALL EQUIPMENT INCLUDING THE EQUIPMENT'S "AS INSTALLED" SIZE(S). MANUFACTURER, MODEL NUMBERS, AND PERFORMANCE RATINGS. Job #: 755.011 High Performance Building Consultants 14. CONTRACTOR TO BE RESPONSIBLE FOR PROTECTION OF THEIR EMPLOYEES FROM ANY LEAD DUST THAT MAY BE ENCOUNTERED. 15. OWNER TO HAVE CHOICE SALVAGE OF ALL PLUMBING FIXTURES AND MECHANICAL EQUIPMENT WHICH ARE PLANNED TO BE REMOVED BY CONTRACTOR. EQUIPMENT NOT SALVAGED BY OWNER SHALL BE REMOVED FROM SITE AND PROPERLY DISPOSED OF BY THE CONTRACTOR. 16. BEFORE REMOVAL OF ANY MECHANICAL EQUIPMENT, CONTRACTOR SHALL RECOVER USED REFRIGERANT IN A PROPERLY LABELED D.O.T. APPROVED REFILLABLE CYLINDER TO MEET E.P.A. STANDARDS. RECOVERED REFRIGERANT MUST BE CHEMICALLY ANALYZED AND REPROCESSED OR DISPOSED OF PER E.P.A. REQUIREMENTS, SECTION 608 OF THE CLEAN AIR ACT AND A.R.I. STANDARD 700. 17. THE LOCATION OF EXISTING UNDERGROUND UTILITIES IS SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. 18. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICAL EQUIPMENT OR PIPING INSULATION IS APPLIED. 19. CONCRETE HOUSEKEEPING PADS TO SUIT MECHANICAL EQUIPMENT SHALL BE SIZED AND LOCATED BY THE MECHANICAL CONTRACTOR. MINIMUM CONCRETE PAD THICKNESS SHALL BE 6 INCHES. PAD SHALL EXTEND BEYOND THE EQUIPMENT A MINIMUM OF 6 INCHES ON EACH SIDE. CONCRETE HOUSEKEEPING PADS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO COORDINATE SIZE AND LOCATION OF CONCRETE HOUSEKEEPING PADS WITH GENERAL CONTRACTOR. 20. UNLESS OTHERWISE SHOWN, LOCATE ALL ROOM THERMOSTATS AND HUMIDISTATS 60" (CENTERLINE) ABOVE FINISHED FLOOR. NOTIFY THE ENGINEER OF ANY ROOMS WHERE THE ABOVE LOCATION CANNOT BE MAINTAINED OR WHERE THERE IS A QUESTION ON LOCATION. 21. ALL SUPPLY DUCTWORK SHALL BE WRAPPED WITH INSULATION FROM FAN TO ROOM TERMINAL UNITS. RECTANGULAR BRANCH TAKE-OFF SUPPLY DUCTWORK FROM ROOM TERMINAL UNITS SHALL BE WRAPPED WITH INSULATION. ALL ROUND SUPPLY DUCTWORK SHALL BE WRAPPED WITH INSULATION. ALL RELIEF AIR/EXHAUST DUCTS SHALL BE WRAPPED WITH INSULATION FROM EXTERIOR OPENING TO BACKDRAFT DAMPERS. ALL OUTSIDE AIR (OA) DUCTWORK TO BE WRAPPED WITH INSULATION FROM INTAKE OPENING TO THE MIXED AIR PLENUM. 22. ALL OUTDOOR AIR DUCTWORK CONNECTED TO LOUVERS TO BE WATER TIGHT CONSTRUCTION WITH DRAIN PAN AND 1 1/2" CONDENSATE DRAIN LINE TO NEAREST SANITARY SEWER. LINE CLEANOUT / WALL CLEANOUT FCO PCHR PCHS PCR PH,Ø PHWR PHWS PIV PRV 23. PROVIDE MINIMUM 36" ACCESS CLEARANCE TO ALL FAN POWERED BOX AND VAV BOX MAINTENANCE PANELS. 24. CONTRACTOR TO COORDINATE DUCTWORK WITH FIRE RATED WALLS AND FLOORS SHOWN ON ARCHITECTURAL DRAWINGS, MAINTAINING NECESSARY RATING OF WALLS. CONTRACTOR IS RESPONSIBLE FOR ALL CONNECTIONS TO SMOKE-FIRE DAMPERS. 25. ALL SA DUCT BRANCH TAKE-OFFS TO DIFFUSER TO BE SAME SIZE AS DIFFUSER NECK UNLESS OTHERWISE NOTED. 26. ALL OUTLET DUCT SIZES OF VARIABLE AIR VOLUME OR FAN-POWERED BOX UNITS NOT SHOWN SHALL BE MINIMUM AS PER BOX SCHEDULE ON MECHANICAL SCHEDULE SHEET OUTLET SIZE. 27. ALL DUCTWORK DIMENSIONS, AS SHOWN ON THE DRAWINGS, ARE INTERNAL CLEAR DIMENSIONS AND DUCT SIZE SHALL BE INCREASED TO COMPENSATE FOR DUCT LINING THICKNESS. DESIGN DEVELOPMENT HWC 180° VALVES A/C ACC ACCU AFC AFF AFG AHU JACKSON, WYOMING HW 180° HVAC EQUIP. AND DUCTWORK MECHANICAL/PLUMBING GENERAL NOTES 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f PLUMBING ABBREVIATIONS TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY MECHANICAL SYMBOLS PIPING / PLUMBING NOT FOR CONSTRUCTION 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker MECHANCIAL LEGEND AND NOTES 4/1/2013 10:37:06 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: M-000 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 K.9 High Performance Building Consultants N F.9 H.5 J J.5 K L.1 L.9 EG-1 18x14 840 M P P.1 P.2 R N.1 A8 N.1 TF-1 14x12 EA T UH-1 B3 CO BUS PARKING 1 GUH-1 A9 T WASH EQUIP/ COMPRESSOR 166 B4 A10 CO CO VEHICLE BYPASS 152 RG-2 26x18 2160 CO CO BUS WASH 153 BOTTOM OF GRILLE TO BE PLACED AT 18" AFF (TYP. 3) A11 M UH-2 BUS PARKING 2 L-4 T T A12 ELEC EQUIP 168 EAST BUS PARKING 150 CO CO B5 EUH-5 RG-2 26x18 2160 A13 T EF-17 ELEC SWITCH GEAR 169 DESIGN DEVELOPMENT UH-3 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY WATER ENTRY 167 BUS PARKING 3 NOT FOR CONSTRUCTION A14 M L-4 EUH-6 A15 CARBON MONOXIDE SENSOR LOCATED EVERY 50'. INTERLOCK WITH ERV-1 THROUGH BAS TO RAMP TO FULL VENTILATION FROM MIN FLOW BASED ON DETECTION OF CO. (TYP.) F CO B6 E A16 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B 4/1/2013 10:37:08 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 LEVEL 1 - AREA A - HVAC PLAN SCALE: 1/8" = 1'-0" A 3123 LEVEL 1 - HVAC PLAN - AREA A M-111 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants RG-2 26x18 2160 30x12 RA DN (TYP. 3) B3 CO CO BUS PARKING 4 B4 CO RG-2 26x18 2160 BOTTOM OF GRILLE TO BE PLACED AT 18" AFF (TYP. 3) RG-2 26x18 2160 BUS PARKING 6 DESIGN DEVELOPMENT B5 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY BUS PARKING 5 NOT FOR CONSTRUCTION CO B6 F C.1 D D.5 E E.5 F F.9 D CHECKED BY: Checker 1 C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: B 4/1/2013 10:37:09 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt C E A 3123 LEVEL 1 - HVAC PLAN - AREA B BUS PARKING LEVEL 1 - AREA B - HVAC PLAN SCALE: 1/8" = 1'-0" M-112 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants J.5 K L L.1 M L.9 N N CO RG-2 30x22 2615 Q 20x18 SA UP 18x16 RA UP 6"Ø EAB1 UP EG-1 6"Ø 75 DRUG TEST 154 FARE ROOM 164 30x14 RA UP SD-1 6"Ø 150 18x16 RA VAV-14 DIRECTOR 155 BREAK/ COPY 156 16x12 TA A1 RG-1 A2 CO 18x20 SA A2 MARKETING 157 SD-1 8"Ø 208 VAV-01 A3 A3 VAV-02 8ø SA RG-1 10x8 TA 12ø SA 10ø SA A1 SD-1 10"Ø 350 10x8 TA RG-1 FSD SD-1 8"Ø 225 R RG-1 A1 A2 OFFICE 159 SD-1 8"Ø 208 VAV-03 A3 VAV-04 A5 A5 LOBBY 160 22x16 SA SG-2 60x4 1114 A5 DESIGN DEVELOPMENT B1 J JACKSON, WYOMING H.5 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY H A7 A7 A7 NOT FOR CONSTRUCTION CO VESTIBULE 161 CO LOST & FOUND 163 SG-2 60x4 1114 ? ? F H H.5 J J.5 K L L.1 L.9 M N CHECKED BY: Checker C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: DRIVE AISLE LEVEL 1 - AREA C - HVAC PLAN SCALE: 1/8" = 1'-0" B 4/1/2013 10:41:17 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt D 2 E A 3123 LEVEL 1 - HVAC PLAN - AREA C M-113 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A B B1 C D D.5 E E.5 F F.9 G H CO CO 30x14 EA UP BOTTOM OF GRILLE TO BE PLACED AT 18" AFF (TYP. ALL) 30x14 EA UP RG-2 30x22 2615 RG-2 30x22 2615 RG-2 30x22 2615 A1 VEHICLE DRIVE AISLE 136 CO A5 30x14 EA UP, TYP. DESIGN DEVELOPMENT A3 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY A2 RG-2 30x22 2615 A7 NOT FOR CONSTRUCTION B2 A B F C D.5 E E.5 F F.9 G CHECKED BY: Checker E H DRIVE AISLE LEVEL 1 - AREA D - HVAC PLAN SCALE: 1/8" = 1'-0" D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: B 4/1/2013 10:37:11 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt 1 D A 3123 LEVEL 1 - HVAC PLAN - AREA D M-114 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f H J H.5 K J.5 L L.1 m GR UP e d e s i g n M P Q 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: M1 R2 M1 www.megroup.com Job #: 755.011 16x10 TA 30x22 TA High Performance Building Consultants TOOL CRIB 110 LUBE/ COMPRESSOR 112 32x22 SA UP R3 SG-1 14x10 495 32x22 SA SG-1 32x30 3750 M2 M2 PARTS STORAGE 111 18x24 SA UP TOOLBOX STORAGE 113 SG-1 24x12 825 34x24 SA LIGHT REPAIR 1 SG-1 24x18 2035 10x6 SA 24x18 SA 10x6 SA UP SG-1 32x30 3485 SG-1 18x12 695 16x36 SA UP SG-1 32x30 3485 MAINTENANCE SUPERVISOR 16x32 SA UP 115 SG-1 32x30 3485 16x32 SA UP 1 M-501 M4 EF-3 BATTERY STORAGE SG-1 114 10x6 200 CO M3 R4 M3 34x24 SA 64x36 TA 16x14 TA PORTABLE EQUIP STORAGE 118 TIRE SHOP 117 PARTS ACCESS 116 R5 M4 SG-1 30x24 3590 BOTTOM OF GRILLE TO BE PLACED AT 18" AFF (TYP. ALL SG) FORKLIFT AISLE 119 24x32 SA UP ? ? R6 GUH-2 32x16 SA UP CO PROVIDE 6" EXHAUST DUCT FROM DISCHARGE OF VEHICLE EXHAUST FAN AT HOSE REEL UP THROUGH ROOF TO RAIN CAP. PORTABLE EQUIP STORAGE 131 R7 T CHASSIS WASH 133 HEAVY REPAIR 3 HEAVY REPAIR 2 HEAVY REPAIR 1 PROVIDE (2) 36x16 TA DUCTS. THE LOWER SHALL BE PLACED AT 1'-0" AFF TO THE BOTTOM OF THE DUCT. THE UPPER SHALL BE PLACED AT 1'-0" BELOW FINISHED CEILING IN WASH EQUIP ROOM FROM THE TOP OF THE DUCT. PROVIDE 6" EXHAUST DUCT FROM DISCHARGE OF VEHICLE EXHAUST FAN AT HOSE REEL UP THROUGH ROOF TO RAIN CAP. WASH EQUIP. 132 SG-1 32x30 3485 M6 R8 12" EA DUCT TO PENETRATE ROOF. PROVIDE WITH ROOF CAP. M6 B1 B1 H 1 H.3 J K MAINTENANCE LEVEL 1 - AREA E - HVAC PLAN L L.1 L.9 M NOT FOR CONSTRUCTION B1 N.1 P Q F E SCALE: 1/8" = 1'-0" D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B 4/1/2013 10:37:14 AM D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: DRAWN BY: Author DESIGN DEVELOPMENT SG-1 32x30 3485 JACKSON, WYOMING M5 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY M5 A 3123 LEVEL 1 - HVAC PLAN - AREA E M-115 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: A www.megroup.com B C E D.5 E.5 F G Job #: 755.011 High Performance Building Consultants M1 SG-1 32x20 3005 SG-1 32x20 3005 32x18 SA SG-1 24x12 915 REBUILD SHOP 101 60x36 SA 18x16 TA 60x36 SA BREAK ROOM 102 16x16 EA UP TO EF-2 CO MEN 103 18x16 TA 16x16 EA M2 EG-1 10x8 150 3" VENT & 6" FLUE TO CONNECT TO EQUIPMENT. MAINTAIN 5' AWAY FROM EXTERIOR WALL ON ROOF. 18x16 TA 16x32 SA WOMEN 104 60x36 SA EG-1 10x8 150 M3 SG-1 24x18 1525 USED OIL BURNER. PROVIDE 8" FLUE WITH RAIN CAP MANUALS & COPY 60x36 SA 106 2 SG-1 36x24 2870 LIGHT REPAIR 3 LIGHT REPAIR 2 LIGHT REPAIR 1 22x32 SA SG-1 32x30 3485 66x30 TA COMMON WORK AREA 105 PROVIDE 4" EXHAUST DUCT FROM DISCHARGE OF VEHICLE EXHAUST FAN AT HOSE REEL UP THROUGH ROOF TO RAIN CAP. SG-1 32X30 3485 30x16 TA M-501 16x32 SA M4 16x32 SA CO M5 PROVIDE 6" EXHAUST DUCT FROM DISCHARGE OF VEHICLE EXHAUST FAN AT HOSE REEL UP THROUGH ROOF TO RAIN CAP. PROVIDE 6" EXHAUST DUCT FROM DISCHARGE OF VEHICLE EXHAUST FAN AT HOSE REEL UP THROUGH ROOF TO RAIN CAP. PROVIDE 6" EXHAUST DUCT FROM DISCHARGE OF VEHICLE EXHAUST FAN AT HOSE REEL UP THROUGH ROOF TO RAIN CAP. HEAVY REPAIR BAYS 120 HEAVY REPAIR 8 S HEAVY HEAVY REPAIR REPAIR 7 7 HEAVY REPAIR 6 HEAVY REPAIR 5 HEAVY REPAIR 3 NATURAL GAS DETECTORS LOCATED ON THE CEILING INTERLOCKED WITH ERV-2 THROUGH THE BAS. PROVIDE 6" EXHAUST DUCT FROM DISCHARGE OF VEHICLE EXHAUST FAN AT HOSE REEL UP THROUGH ROOF TO RAIN CAP. 16x32 SA PROVIDE 6" EXHAUST DUCT FROM DISCHARGE OF VEHICLE EXHAUST FAN AT HOSE REEL UP THROUGH ROOF TO RAIN CAP. NOT FOR CONSTRUCTION CO SG-1 32x30 3520 PROVIDE 6" EXHAUST DUCT FROM DISCHARGE OF VEHICLE EXHAUST FAN AT HOSE REEL UP THROUGH ROOF TO RAIN CAP. CO M6 B1 CO F A B C D E F G E H D C 1 DESIGN DEVELOPMENT No REVISION/SUBMISSION CHECKED BY: Checker 4/4/2013 9:54:15 AM D:\My Data\Documents\MEG-START_MEP_2013_miles.dake.rvt DRAWN BY: Author MAINTENANCE LEVEL 1 - AREA F - HVAC PLAN SCALE: 1/8" = 1'-0" B A 4/8/13 DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: 1 DESIGN DEVELOPMENT FORKLIFT AISLE 119 SG-1 32x30 3520 JACKSON, WYOMING SG-1 32x30 3520 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 16x42 SA SG-1 32x30 3520 3123 LEVEL 1 - HVAC PLAN - AREA F M-116 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) 1. INTERLOCK EF-1 AND L-1 WITH NATURAL GAS SENSOR. LOUVER TO OPEN AND FAN TO ENERGIZE UPON DETECTINO OF 1/4 OF THE LOWER FLAMMABLE LIMIT PER NFPA 52. 2. INTERLOCK EF-1 AND L-1 WITH THERMOSTAT TO VENTILATE AND COOL THE SPACE WHEN TEMPERATURE EXCEEDS 80°F. 3. ALL UH'S AND EF TO BE SPARK RESISTANT AND CRITICAL FACILITY CLASS 1 RATED. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants 1 L-6 T ELECTRICAL/STORAGE 3 14x14 EA UP S COMPRESSORS 1 973.4 SF OFFICE 2 16x16 EA UP EUH-1 EUH-3 Z 1 CNG LEVEL 1 - HVAC PLAN SCALE: 1/8" = 1'-0" DESIGN DEVELOPMENT EUH-2 JACKSON, WYOMING CONNECT 42"Ø DUCT TO NATURAL GAS COMPRESSOR COOLER AND ROUTE UP TO ROOF HOOD. TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY M T M L-3 NOT FOR CONSTRUCTION 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker LEVEL 1 - HVAC PLAN - CNG BUILDING 4/1/2013 10:37:17 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: M-117 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n P P.1 P.2 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: R www.megroup.com N.1 B2 30x12 RA 54x36 RA 24x60 SA PLENUM A8 FSD B3 High Performance Building Consultants S 34x10 SD-1 14"Ø 980 VAV-07 SD-1 36x24 3600 TYP. 4 Job #: 755.011 A8 30x12 RA TRAINING 70x18 TA 209 BUS PARKING 1 GUH-1 T HALL 208 FSD A9 A9 RG-1 30x36 RA 32x18 TA SD-1 10"Ø 325 8x8 TA T QUIET 210 RG-1 TABLE & CHAIR 209A SD-1 8"Ø 230 RG-1 SD-1 6"Ø 165 A10 A10 12x8 SA B4 8x8 TA VAV-08 VEHICLE BYPASS 152 30x12 RA SD-1 8"Ø 230 T RG-1 QUIET 211 BUS WASH 153 BOOKKEEPING 213A SD-1 6"Ø 165 VAV-09 36x16 SA 30x12 RA 32x18 TA 30x12 RA DN (TYP. 3) 12x8 SA RG-1 32x18 TA A11 SD-1 10"Ø 325 BUS PARKING 2 A11 SD-1 12"Ø 675 RG-1 SUPERS 213 T VAV-10 22x10 SA T EAST BUS PARKING 150 SD-1 16"Ø 1500 RG-1 B5 24x16 SA DRIVERS 215 1,111.41 SF VAV-12 30x12 RA A13 30x12 RA T A13 BREAK SD-1 214 10"Ø 550 MANUAL BALANCING DAMPER, TYP. BUS PARKING 3 VAV-13 SD-1 16"Ø 1500 A14 A14 A15 A15 STAIR 2 S2 B6 NOT FOR CONSTRUCTION A16 F F.9 H.5 J K J.5 L L.1 L.9 M CHECKED BY: Checker C LEVEL 1 - AREA A - HVAC PLAN 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: SCALE: 1/8" = 1'-0" B 4/1/2013 10:37:19 AM D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt 1 E N D DRAWN BY: Author DESIGN DEVELOPMENT A12 SD-1 12"Ø 675 JACKSON, WYOMING A12 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 20x36 RA VAV-11 A 3123 LEVEL 2 - HVAC PLAN - AREA A M-121 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants 30x12 RA 30x12 RA DN (TYP. 3) B3 BUS PARKING 4 B4 30x12 RA 30x12 RA DESIGN DEVELOPMENT B5 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY BUS PARKING 5 BUS PARKING 6 NOT FOR CONSTRUCTION F E B6 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: C.1 D D.5 E E.5 F F.9 CHECKED BY: Checker B 4/1/2013 10:37:20 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt C 1 A 3123 LEVEL 2 - HVAC PLAN - AREA B BUS PARKING LEVEL 2 - AREA B - HVAC PLAN SCALE: 1/8" = 1'-0" M-122 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants K L M N N Q R 14"Ø EA UP 6"Ø EA DN B1 WOMEN 205 20x18 SA DN 18x18 SA DN 20x36 RA MEN 203 1 M-401 EG-1 10"Ø 280 EG-1 10"Ø 280 SD-1 6"Ø 100 10x10 RA RG-1 A1 SG-1 24x18 1925 RG-1 10x10 TA VAV-05 A2 A2 10x10 SA EG-1 12x12 80 A1 60x36 SA EG-1 6"Ø 65 LOCKERS 207 SD-1 6"Ø 170 54x36 RA A3 A3 A5 A5 VAV-06 SG-1 36x24 3485 56x20 RA 22x18 SA SG-1 36x24 3875 SG-2 80x4 1510 48x30 SG-2 80x4 1510 K.9 42x18 SA A7 A7 RG-1 46x18 5247 6 x3 20 EA DESIGN DEVELOPMENT J.5 JACKSON, WYOMING J H.5 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY H NOT FOR CONSTRUCTION H 1 H.3 J J.5 K L M N DRIVE AISLE LEVEL 2 - AREA C - HVAC PLAN SCALE: 1/8" = 1'-0" F D E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B 4/1/2013 10:37:23 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: A 3123 LEVEL 2 - HVAC PLAN - AREA C M-123 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A B C D E D.5 E.5 F G H B1 30x14 RA DN (TYP. 4) A2 A3 VEHICLE DRIVE AISLE 136 A5 DESIGN DEVELOPMENT A1 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 20x36 RA NOT FOR CONSTRUCTION A7 20x36 RA F A B C D D.5 E E.5 F F.9 H D E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 10:37:24 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: DRIVE AISLE LEVEL 2 - AREA D - HVAC PLAN B A 3123 LEVEL 2 - HVAC PLAN - AREA D SCALE: 1/8" = 1'-0" M-124 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H P J K L.1 M Q P R2 M1 Q R2 M1 SEE TYPICAL HVAC PLAN ON DETAIL 1 HOUSING UNIT 7 HOUSING UNIT 3 R3 M2 R3 M2 R4 R4 EF-4 EF-5 32x16 SA DN (TYP. 3) MAINTENANCE SUPERVISOR 115 32x16 SA R5 M4 PORTABLE EQUIP STORAGE 118 TIRE SHOP 117 PARTS ACCESS 116 HOUSING UNIT 2 SG-1 8x6 160 M4 32x16 SA SEE TYPICAL HVAC PLAN ON DETAIL 1 RG-2 ? ? 32x24 SA M5 M5 72x16 SA DN LAUNDRY 200 SD-1 18x10 600 HOUSING UNIT 5 8x6 SA 8x6 RA EF-6 SG-1 8x6 80 ? ? 72x16 SA 96x46 OA PLENUM RG-2 10x8 SA R6 8x8 SA R6 8x8 RA 14x10 RA UTILITY 200A 70x32 SA 18x16 SA UP 14x12 SA DN 14x10 SA 18x16 RA UP 14x12 RA DN 10x8 RA 32x24 SA DN TYPICAL STUDIO WILL RECIEVE 80 CFM SUPPLY AIR TO MAIN ROOM AND (1) EXHAUST FAN DUCTED TO EXTERIOR WITH WALL CAP. 84x48 RETURN OPENINGS IN BOTTOM OF RETURN DUCT. COVER DUCT OPENING WITH BIRDSCREEN. (TYP 2) HEAVY REPAIR 2 R7 38x32 SA HOUSING UNIT 1 84x48 EA R7 ? ? HEAVY REPAIR 1 60x36 SA 2 M-401 76x32 SA 76x32 EA DESIGN DEVELOPMENT HOUSING UNIT 6 JACKSON, WYOMING M-501 TYPICAL HOUSING UNIT 3-6: EACH RESTROOM SHALL HAVE 1 EXHAUST FAN DUCTED TO EXTERIOR WITH WALL CAP. EACH MAIN ROOM TO RECIEVE 160 CFM. 34x24 SA DN SA 1 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 10x8 SA M3 6 x1 36 10x8 RA M3 114x32 SA 38x28 EA 32x16 SA HOUSING UNIT 4 R8 L-2 BD ERV-2 ? ? NOT FOR CONSTRUCTION R8 84x48 RA 76x32 RA BD 114x32 RA 76x32 OA 38x32 RA 32x16 SA DN M6 B1 12" EA DUCT TO PENETRATE ROOF. PROVIDE WITH ROOF CAP. M6 B1 B1 H H.3 J K L F B1 E M D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: CHECKED BY: Checker 2 4/1/2013 10:37:28 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt N.1 P S RESIDENTIAL LEVEL 3 - AREA E - HVAC PLAN SCALE: 1/8" = 1'-0" N 1 MAINTENANCE LEVEL 2 - AREA E - HVAC PLAN P Q S B A 3123 LEVEL 2 - HVAC PLAN - AREA E SCALE: 1/8" = 1'-0" M-125 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com A B C D E F G Job #: 755.011 H High Performance Building Consultants M1 M2 3" VENT & 6" FLUE TO CONNECT TO EQUIPMENT. MAINTAIN 5' AWAY FROM EXTERIOR WALL ON ROOF. USED OIL BURNER. PROVIDE 8" FLUE WITH RAIN CAP 2 M-501 M3 COMMON WORK AREA 105 MANUALS & COPY 106 84x48 SA DN 32x16 SA DN 32x16 SA DN 42x16 SA DN M4 M5 HEAVY REPAIR BAYS 120 HEAVY REPAIR 8 HEAVY HEAVY REPAIR REPAIR 7 7 HEAVY REPAIR 6 HEAVY REPAIR 5 HEAVY REPAIR 3 60x36 SA DESIGN DEVELOPMENT TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY PROVIDE SUPPLY BRANCHES THAT SERVE (1) DIFFUSER WITH MANUAL BALANCING DAMPER, TYP. ALL. JACKSON, WYOMING 34x30 SA 84x48 RA NOT FOR CONSTRUCTION 84x48 RETURN OPENINGS IN BOTTOM OF RETURN DUCT. COVER DUCT OPENING WITH BIRDSCREEN. (TYP 4) 16x32 SA 32x16 SA M6 B1 F A B C D E F G E H D C 1 DESIGN DEVELOPMENT No REVISION/SUBMISSION CHECKED BY: Checker 4/4/2013 9:57:29 AM DRAWN BY: Author D:\My Data\Documents\MEG-START_MEP_2013_miles.dake.rvt 1 SCALE: 1/8" = 1'-0" B A DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: MAINTENANCE LEVEL 2 - AREA F - HVAC PLAN 4/8/13 3123 LEVEL 2 - HVAC PLAN - AREA F M-126 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants EF-1 DESIGN DEVELOPMENT RH-2 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY RH-1 NOT FOR CONSTRUCTION 1 DRIVE AISLE ROOF - AREA C - MECHANICAL PLAN SCALE: 1/8" = 1'-0" F D E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B 4/1/2013 10:37:32 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: A 3123 ROOF - MECHANICAL PLAN - AREA C M-133 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 RH-3 6" VENT TO MECHANICAL EQUIPMENT. PROVIDE WITH RAIN CAP. PROVIDE 12" EXHAUST DUCT FROM DISCHARGE OF MECHANICAL EQUIPMENT UP THROUGH ROOF WITH RAIN CAP. DESIGN DEVELOPMENT ERV-3 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY High Performance Building Consultants NOT FOR CONSTRUCTION EF-1 1 MAINTENANCE ROOF - AREA E - MECHANICAL PLAN F E SCALE: 1/8" = 1'-0" D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B 4/1/2013 10:37:35 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: A 3123 ROOF - MECHANICAL PLAN - AREA E M-135 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants EF-2 4" VENT TO MECHANICAL EQUIPMENT. PROVIDE WITH RAIN CAP. 4" VENT TO MECHANICAL EQUIPMENT. PROVIDE WITH RAIN CAP. 6" VENT / 4" EXHAUST TO EQUIPMENT. PROVIDE WITH RAIN CAP 8" VENT TO MECHANICAL EQUIPMENT. PROVIDE WITH RAIN CAP. 6" VENT TO MECHANICAL EQUIPMENT. PROVIDE WITH RAIN CAP. 6" VENT TO MECHANICAL EQUIPMENT. PROVIDE WITH RAIN CAP. DESIGN DEVELOPMENT JACKSON, WYOMING 6" VENT TO MECHANICAL EQUIPMENT. PROVIDE WITH RAIN CAP. TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 6" VENT TO MECHANICAL EQUIPMENT. PROVIDE WITH RAIN CAP. 6" VENT TO MECHANICAL EQUIPMENT. PROVIDE WITH RAIN CAP. NOT FOR CONSTRUCTION 1 MAINTENANCE ROOF - AREA F - MECHANICAL PLAN SCALE: 1/8" = 1'-0" F D E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B 4/1/2013 10:37:37 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: A 3123 ROOF - MECHANICAL PLAN - AREA F M-136 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants RH-5 EF-16 Z 1 DESIGN DEVELOPMENT RH-4 JACKSON, WYOMING EF-18 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 1 NOT FOR CONSTRUCTION CNG ROOF - HVAC PLAN SCALE: 1/8" = 1'-0" 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker ROOF - MECHANICAL PLAN - CNG BUILDING 4/1/2013 10:37:38 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: M-137 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) CONSTRUCTION JOINTS SHALL BE COORDINATED WITH RADIANT TUBING ZONING LAYOUT. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: F.9 H.5 P K.9 J.5 P.1 www.megroup.com R Job #: 755.011 High Performance Building Consultants T LOST & FOUND 163 B2 T RHM-10 A8 RHM-8B VEHICLE BYPASS 152 T B3 BUS PARKING 1 G 1 1/4" HWR 1 1/4" HWS UH-1 A9 H RHM-6 BUS WASH 153 WASH EQUIP/ COMPRESSOR 166 A10 B4 T VEHICLE BYPASS 152 BUS PARKING 2 A11 UH-2 A12 ELEC EQUIP 168 EAST BUS PARKING 150 T B5 A13 DESIGN DEVELOPMENT UH-3 RHM-5 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY WATER ENTRY 167 ELEC SWITCH GEAR 169 BUS PARKING 3 NOT FOR CONSTRUCTION A14 RHM-4 A15 F B6 E A16 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B H.3 4/1/2013 10:37:40 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 J LEVEL 1 - AREA A - HVAC PLAN SCALE: 1/8" = 1'-0" K K.9 L.1 L.9 M N P A 3123 LEVEL 1 - HYDRONIC PLAN - AREA A R M-141 GENERAL NOTES 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f 1. (THIS SHEET) CONSTRUCTION JOINTS SHALL BE COORDINATED WITH RADIANT TUBING ZONING LAYOUT. m GR UP e d e s i g n C.1 D.5 E.5 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: F.9 www.megroup.com Job #: 755.011 High Performance Building Consultants T RHM-8A B3 BUS PARKING 4 RHM-3 B4 T BUS PARKING 5 B5 T BUS PARKING 6 DESIGN DEVELOPMENT WEST BUS PARKING 158 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY RHM-2 RHM-1 NOT FOR CONSTRUCTION B6 F C.1 D E F D E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B 4/1/2013 10:37:41 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 A 3123 LEVEL 1 - HYDRONIC PLAN - AREA B BUS PARKING LEVEL 1 - AREA B - HYDRONIC PLAN SCALE: 1/8" = 1'-0" M-142 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) CONSTRUCTION JOINTS SHALL BE COORDINATED WITH RADIANT TUBING ZONING LAYOUT. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H.5 J.5 N Q R BBH-1 T T 2" HWS/R TO SERVE RESIDENTIAL WING DIRECTOR 155 1-1/2" HWS/R TO SERVE 1ST FL ADMIN NORTH RHM-9A FARE ROOM 164 DRUG TEST 154 RHM-9B BREAK/ COPY 156 A1 A2 1 1/2" HWS 1 1/2" HWR VAV-01 VEHICLE DRIVE AISLE 136 MARKETING 157 A1 A2 OFFICE 159 VAV-03 A3 A3 VAV-04 A5 A5 BBH-1 1 1/2" HWS 1 1/2" HWR BBH-1 K.9 LOBBY 160 A7 DESIGN DEVELOPMENT ELEVATOR E1 JACKSON, WYOMING VAV-02 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY B1 A7 COMM 165 VESTIBULE 161 LOST & FOUND 163 NOT FOR CONSTRUCTION VESTIBULE 162 P.2 H H.3 J K L L.1 L.9 M N N.1 F 1 E DRIVE AISLE LEVEL 1 - AREA C - HYDRONIC PLAN SCALE: 1/8" = 1'-0" D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B 4/1/2013 10:37:44 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: A 3123 LEVEL 1 - HYDRONIC PLAN - AREA C M-143 GENERAL NOTES 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f 1. (THIS SHEET) CONSTRUCTION JOINTS SHALL BE COORDINATED WITH RADIANT TUBING ZONING LAYOUT. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A C D D.5 E E.5 F G H T B1 A3 VEHICLE DRIVE AISLE 136 A5 DESIGN DEVELOPMENT A2 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY A1 A7 NOT FOR CONSTRUCTION RHM-7 RHM-8A T T T RHM-8B B2 F A B C D E F G E H D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 10:37:45 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: DRIVE AISLE LEVEL 1 - AREA D - HYDRONIC PLAN SCALE: 1/8" = 1'-0" B A 3123 LEVEL 1 - HYDRONIC PLAN - AREA D M-144 GENERAL NOTES CONSTRUCTION JOINTS SHALL BE COORDINATED WITH RADIANT TUBING ZONING LAYOUT. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f 1. (THIS SHEET) m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com H H.3 J K J.5 L.1 P M Q Job #: 755.011 High Performance Building Consultants R2 M1 TOOL CRIB 110 1-1/2" HWS/R TO SERVE BBH ON 2ND FLOOR LUBE/ COMPRESSOR 112 R3 M2 LIGHT REPAIR BAYS 107 TOOLBOX STORAGE 113 PARTS STORAGE 111 R4 BATTERY STORAGE 114 T M3 RHM-14 MAINTENANCE SUPERVISOR 115 M4 TIRE SHOP 117 R5 T RHM-15 PARTS ACCESS 116 PORTABLE EQUIP STORAGE 118 M5 HEAVY REPAIR 2 CHASSIS WASH 133 PORTABLE EQUIP STORAGE 131 HEAVY REPAIR 1 1-1/2" HWS/R TO BE LOCATED WITHIN INSULATED FLOOR CAVITY R7 1-1/2" HWS/R UP TO SERVE 3RD FLOOR RESIDENTIAL DESIGN DEVELOPMENT R6 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY FORKLIFT AISLE 119 R8 NOT FOR CONSTRUCTION T WASH EQUIP. 132 T RHM-16B RHM-9A M6 B1 B1 F H H.3 J K L L.1 M N.1 P Q CHECKED BY: Checker C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: MAINTENANCE LEVEL 1 - AREA E - HYDRONIC PLAN SCALE: 1/8" = 1'-0" B 4/1/2013 10:37:47 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt D 1 E A 3123 LEVEL 1 - HYDRONIC PLAN - AREA E M-145 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) CONSTRUCTION JOINTS SHALL BE COORDINATED WITH RADIANT TUBING ZONING LAYOUT. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A B C D E D.5 F G H M1 BREAK ROOM 102 JANITOR 103A REBUILD SHOP 101 MEN 103 M2 RMH-19 RMH-18A LIGHT REPAIR 3 LIGHT REPAIR 1 LIGHT REPAIR 2 T WOMEN 104 T M3 T RHM-18B COMMON WORK AREA 105 MANUALS & COPY 106 M4 M5 RHM-17A HEAVY REPAIR BAYS 120 HEAVY REPAIR 8 HEAVY REPAIR 7 HEAVY REPAIR 6 HEAVY REPAIR 5 HEAVY REPAIR 4 HEAVY REPAIR 3 RHM-17B DESIGN DEVELOPMENT FORKLIFT AISLE 119 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY T NOT FOR CONSTRUCTION RHM-16A T M6 T F E B1 D C 1 DESIGN DEVELOPMENT No REVISION/SUBMISSION C D E F G H CHECKED BY: Checker B 4/4/2013 9:54:22 AM D:\My Data\Documents\MEG-START_MEP_2013_miles.dake.rvt DRAWN BY: Author B 1 MAINTENANCE LEVEL 1 - AREA F - HYDRONIC PLAN SCALE: 1/8" = 1'-0" A DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: A 4/8/13 3123 LEVEL 1 - HYDRONIC PLAN - AREA F M-146 GENERAL NOTES 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f 1. (THIS SHEET) CONSTRUCTION JOINTS SHALL BE COORDINATED WITH RADIANT TUBING ZONING LAYOUT. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com F.9 H.5 K.9 J.5 P.2 R Job #: 755.011 High Performance Building Consultants 3" HWR 3" HWS N.1 B2 A8 S 2" HWS VAV-07 B3 TRAINING 209 GUH-1 BUS PARKING 1 A9 2" HWR 2 1/2" HWS 2 1/2" HWR 2 1/2" HWS 2 1/2" HWR VEHICLE BYPASS 152 2-1/2" HWS/R TO SERVE RHM4,5,6,10 EAST BUS PARKING 150 HALL 208 BUS WASH 153 TABLE & CHAIR 209A QUIET 210 A10 B4 VAV-08 QUIET 211 BOOKKEEPING 213A VAV-09 A11 VAV-10 VAV-11 A12 DRIVERS 215 B5 VAV-12 A13 T BREAK 214 BUS PARKING 3 DESIGN DEVELOPMENT TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY SUPERS 213 JACKSON, WYOMING BUS PARKING 2 VAV-13 A14 NOT FOR CONSTRUCTION A15 STAIR 2 S2 F B6 B6 E A16 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker F.9 4/1/2013 10:37:51 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: H.5 J J.5 K L L.9 M N P.2 N.1 1 LEVEL 1 - AREA A - HVAC PLAN SCALE: 1/8" = 1'-0" R B A 3123 LEVEL 2 - HYDRONIC PLAN - AREA A M-151 GENERAL NOTES CONSTRUCTION JOINTS SHALL BE COORDINATED WITH RADIANT TUBING ZONING LAYOUT. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f 1. (THIS SHEET) m GR UP e d e s i g n C D E D.5 E.5 F 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: F.9 www.megroup.com Job #: 755.011 High Performance Building Consultants 2 1/2" HWR 2 1/2" HWS B3 2-1/2" HWS/R TO SERVE RHM-10,11,12 BUS PARKING 4 B4 BUS PARKING 6 DESIGN DEVELOPMENT B5 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY BUS PARKING 5 NOT FOR CONSTRUCTION B6 F D D.5 E E.5 F D CHECKED BY: Checker 1 C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: B 4/1/2013 10:37:52 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt C.1 E A 3123 LEVEL 2 - HYDRONIC PLAN - AREA B BUS PARKING LEVEL 2 - AREA B - HYDRONIC PLAN SCALE: 1/8" = 1'-0" M-152 GENERAL NOTES CONSTRUCTION JOINTS SHALL BE COORDINATED WITH RADIANT TUBING ZONING LAYOUT. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f 1. (THIS SHEET) m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants L M NN.1 4" HWS 4" HWR Q B1 BBH-1 2" HWR ? ? 2" HWS WOMEN 205 MEN 203 VAV-05 A1 1" HWS 1" HWR A2 LOCKERS 207 4" HWR 202 4" HWS 2" HWR 2" HWS ERV-1 A3 A3 A5 A5 1 1/4" HWR 2" HWR 2" HWS LOBBY 160 2" HWS 2" HWR VEHICLE DRIVE AISLE 136 3" HWR 3" HWS VEHICLE DRIVE AISLE 136 VAV-06 1 1/4" HWS 2 1/2" HWR 2 1/2" HWS 6" HWR 4" HWR 4" HWS 6" HWS 2" HWR 2" HWS A1 A2 HALL 1 M-401 2" HWS/R TO SERVE RHM-9A,9B BBH-1 2" HWR 2" HWS R AHU-1 K.9 A7 A7 DESIGN DEVELOPMENT K JACKSON, WYOMING J H.5 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY H NOT FOR CONSTRUCTION H 1 H.3 J K DRIVE AISLE LEVEL 2 - AREA C - HYDRONIC PLAN L M N P.2 R N.1 SCALE: 1/8" = 1'-0" F D E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B 4/1/2013 10:37:55 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: A 3123 LEVEL 2 - HYDRONIC PLAN - AREA C M-153 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) CONSTRUCTION JOINTS SHALL BE COORDINATED WITH RADIANT TUBING ZONING LAYOUT. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants D E D.5 E.5 F G B1 B1 A1 A1 A2 A2 A3 A3 2" HWS/R TO SERVE RHM-7,8A,8B 2" HWR 2" HWS VEHICLE DRIVE AISLE 136 A5 A5 A7 A7 DESIGN DEVELOPMENT C JACKSON, WYOMING B TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY A NOT FOR CONSTRUCTION B2 B2 A B C DRIVE AISLE LEVEL 2 - AREA D - HYDRONIC PLAN D.5 E E.5 F F.9 H F D CHECKED BY: Checker E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: SCALE: 1/8" = 1'-0" B 4/1/2013 10:37:56 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt 1 D A 3123 LEVEL 2 - HYDRONIC PLAN - AREA D M-154 GENERAL NOTES 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f 1. (THIS SHEET) CONSTRUCTION JOINTS SHALL BE COORDINATED WITH RADIANT TUBING ZONING LAYOUT. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H P H.3 J K L M Q P R2 R2 Q R2 M1 BBH-1 TYP. 1-1/2" HWS/R TO SERVE BBH ON 3RD FLOOR R3 R3 R3 HOUSING UNIT 3 BBH-01 TYP. ALL M2 BBH-1 TYP. R4 R4 R4 BBH-1 TYP. M3 PARTS ACCESS 116 M4 PORTABLE EQUIP STORAGE 118 TIRE SHOP 117 HOUSING UNIT 2 R5 2" HWS/R TO SERVE RHM-14,15 R6 R6 2" HWR 2" HWS R6 M5 1" HWS/R UP TO ERV-3 R7 1-1/2" HWS/R TO SERVE RHM-16A HEAVY REPAIR 2 1" HWS/R DN HOUSING UNIT 1 R7 BBH-1 TYP. 4" HWR R7 4" HWR 4" HWS 4" HWS BBH-01 TYP. ALL 1 1/2" HWR 1 1/2" HWS 2 M-401 HEAVY REPAIR 1 DESIGN DEVELOPMENT R5 JACKSON, WYOMING R5 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY M-501 1 1/2" HWR MAINTENANCE SUPERVISOR 115 1 1" HWS/R UP R8 NOT FOR CONSTRUCTION R8 1-1/2" HWS/R DN M6 M6 B1 B1 B1 H H.3 J K L F E M D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: CHECKED BY: Checker 2 4/1/2013 10:38:01 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt N.1 P N.1 R S B RESIDENTIAL LEVEL 3 - AREA E - HYDRONIC PLAN SCALE: 1/8" = 1'-0" 1 A 3123 LEVEL 2 - HYDRONIC PLAN - AREA E MAINTENANCE LEVEL 2 - AREA E - HYDRONIC PLAN SCALE: 1/8" = 1'-0" M-155 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) CONSTRUCTION JOINTS SHALL BE COORDINATED WITH RADIANT TUBING ZONING LAYOUT. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A B C D E D.5 E.5 F G H M1 M2 M3 COMMON WORK AREA 105 ? ? 4" HWS/R TO SERVE RHM16A,17A,17B,18A,18B,19 HEAVY REPAIR BAYS 120 HEAVY REPAIR 8 HEAVY REPAIR 7 HEAVY REPAIR 6 HEAVY REPAIR 5 HEAVY REPAIR 4 HEAVY REPAIR 3 NOT FOR CONSTRUCTION M6 F E B1 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. B C D D.5 E E.5 F G H CHECKED BY: Checker B 4/1/2013 10:38:02 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: A 1 MAINTENANCE LEVEL 2 - AREA F - HYDRONIC PLAN SCALE: 1/8" = 1'-0" DESIGN DEVELOPMENT M5 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY M4 A 3123 LEVEL 2 - HYDRONIC PLAN - AREA F M-156 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f KEY NOTES 1. X m GR UP e d e s i g n (THIS SHEET) BOILER B-3 AND HWP-3 TO BE PLANNED FOR FUTURE PHASE, BUT INSTALLED IN PHASE 1. 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com GENERAL NOTES Job #: 755.011 (THIS SHEET) High Performance Building Consultants 1. REFER TO MECHANICAL NOTES AND SYMBOLS LEGEND FOR GENERAL NOTES. 2. REFER TO M4-01 FOR ENLARGED MECHANICAL ROOM PLAN. REDUCED PRESSURE BACKFLOW PREVENTER 1" DCW MAKE-UP ADJUSTABLE PRV 6"HWR HWR FROM BUILDING 6"HPWR AUTO AIR VENT AIR SEPARATOR AS-1 6"HWS HWS TO BUILDING PRESSURE SWITCH AT 25 PSI (ADJ) S PRESSURE GAUGE 1 1/2"G CHECK VALVE/BALANCE VALVE/SHUT-OFF VALVE OR AT CONTRACTORS OPTION PROVIDE TRIPLE DUTY VALVE ON PUMP DISCHARGE. ISOLATION VALVE 2"G B-3 B-1 CHECK VALVE B-2 PRESSURE RELIEF VALVE SET AT 60 PSI. EXTEND TO FLOOR DRAIN (TYP. 3) UNION WALL MOUNTED VFD FOR HWP-1 1 1 1/2"G CHEMICAL FEEDER WALL MOUNTED VFD FOR HWP-2 VFD VFD VFD BP-2 CHECK VALVE ET-1 BP-3 LOW LEVEL SENSOR TIED TO BMS UNION (TYP.) 3/4" BALL DRAIN VALVE WITH HOSE CONNECTION WALL MOUNTED VFD FOR HWP-3 SUCTION DIFFUSER WITH STRAINER (TYP.) 4" CONCRETE PAD MAKE-UP GLYCOL WATER FEED SYSTEM WITH 50 GALLON STORAGE TANK AND SYSTEM FILL PUMP 1 PRESSURIZED VERTICAL BLADDER TYPE EXPANSION TANK 3/ " BALL DRAIN VALVE 4 WITH 3/4 " HOSE. CONN. AND CAP ON CHAIN REFER TO BASE MOUNTED PUMP DETAIL. HYDRONIC PIPING SCHEMATIC SCALE: 1/8" = 1'-0" HWP-2 HWP-3 1 DESIGN DEVELOPMENT HWP-1 MECHANICAL ROOM FLOOR JACKSON, WYOMING DIRT LEG (TYP.) TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY GAS COCK (TYP.) 3/4" CFT-1 1 1/2"G BP-1 CONTROL VALVE ADJUST TO REGULATE CHEMICAL FEED 6"HWS 1 1/2"G 1 1/2" EXP. LINE 6"HWS CHECK VALVE (TYP.) 4" HWS 6"HWS 4" HWS 6"HWS 4" HWR 6"HWS 3/4" 4" HWR 4" HWS 3/4" BALL DRAIN VALVE WITH 3/4" HOSE. CONN. & CAP ON CHAIN. (TYP) 6"HWS 4" HWS 4" HWS 6"HWS NOT FOR CONSTRUCTION 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker MECHANICAL DIAGRAMS 4/1/2013 10:38:03 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: M-301 B C D E F H G J H.3 K L M L.1 N 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f A R P Q R1 M1 BREAK ROOM 102 ZONE 16 R2 TOOL CRIB 110 LUBE/ COMPRESSOR 112 GENERAL NOTES REBUILD SHOP 101 ALL ZONES IDENTIFIED ON SHEET SHALL BE RADIANT FLOOR HEATING. ALL OTHER ROOMS NOT SHOWN WITHIN A ZONE AND POSSESSING AN EXTERIOR WALL SHALL BE HEATED WITH OTHER METHODS. 2. EACH ZONE INDICATED ON PLANS REQUIRES ITS OWN RADIANT TUBING MANIFOLD HEADER, THERMOSTAT, SUPPLY WATER BLENDING VALVE, AND ZONE CIRCULATOR PUMP. MEN 103 PARTS STORAGE 111 M2 WOMEN & JANITOR 104 www.megroup.com Job #: 755.011 BATTERY STORAGE 114 LIGHT REPAIR 1 109 LIGHT REPAIR 2 108 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: ZONE 11 TOOLBOX STORAGE 113 ZONE 15A LIGHT REPAIR 3 107 R3 m GR UP e d e s i g n (THIS SHEET) 1. R4 High Performance Building Consultants M3 M4 MAINTENANCE SUPERVISOR 115 MANUALS & COPY 106 COMMON WORK AREA 105 ZONE 15B ZONE 12 PORTABLE EQUIP STORAGE 118 TIRE SHOP 117 PARTS ACCESS 116 R5 FORKLIFT AISLE 119 M5 ? ? ZONE 14A R6 ZONE 13B ZONE 13A ? ? WALKWAY 120 ? ? ? ? HEAVY REPAIR 8 121 HEAVY REPAIR 7 122 HEAVY REPAIR 6 123 HEAVY REPAIR 5 124 HEAVY REPAIR 4 125 HEAVY REPAIR 3 126 HEAVY REPAIR 1 128 HEAVY REPAIR 2 127 R7 P.1 P.2 ZONE 14B PORTABLE EQUIP STORAGE 131 R8 M6 B1 R9 DRUG TEST 154 ZONE 7 ZONE 8B ZONE 8A DIRECTOR 155 ZONE 9B ZONE 9A BREAK/ COPY 156 MARKETING 157 A1 A2 OFFICE 159 A3 A4 VEHICLE DRIVE?AISLE ? 136 UP A5 A6 LOBBY 160 A7 S LOST & FOUND 163 A8 C.1 ZONE 3 ZONE 6 ZONE 10 ? FARE ROOM ? 164 BUS PARKING 4 145 BUS PARKING 1 138 B3 A9 WASH EQUIP/ COMPRESSOR 166 A10 B4 ZONE 2 VEHICLE BYPASS 152 ZONE 5 BUS WASH 153 A11 BUS PARKING 2 140 BUS PARKING 5 147 WATER ENTRY 167 DESIGN DEVELOPMENT B2 JACKSON, WYOMING VESTIBULE 162 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY VESTIBULE 161 A12 ELEC EQUIP 168 WALKWAY 158 NOT FOR CONSTRUCTION B5 A13 ZONE 1 ELEC SWITCH GEAR 169 ZONE 4 BUS PARKING 6 149 BUS PARKING 3 142 A14 A15 UP B6 A16 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker D.5 4/1/2013 10:38:04 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: E.5 F.9 G.1 H.5 1 J.5 L.9 N.1 T 3123 HYDRONIC ZONING PLAN HYDRONIC ZONING PLAN SCALE: 1/16" = 1'-0" M-302 M N N.1 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f L M6 M6 R9 B1 B1 2" HWR HYDRONICS TO BE ROUTED ABOVE DUCTWORK 2" HWS 20x18 SA/18x18 RA DN TO SERVE OFFICE ZONES ON LOWER LEVEL m GR UP e d e s i g n 18x16 RA K L L.1 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: M www.megroup.com Job #: 755.011 High Performance Building Consultants A1 A1 M4.5 2" HWS 2" HWR A2 A2 60x36 SA M5 M5 60x36 EA UP TO RH-1 60x36 OA ERV-1 72x16 SA A3 A3 24x16 RA 54x36 RA L.1 4" HWR 4" HWS 84x48 EA UP TO RH-3 2" HWS 2" HWR 8 x1 0 2 A5 76x32 SA 76x32 EA 56x20 RA ERV-2 38x28 SA BP-1 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY B-1 L-2 SA & RA TO SERVE OFFICE ZONE 38x28 OA ERV-2 62x14 EA UP TO RH-2 BD 38x28 RA BP-2 B-2 HWP-2 ERV-2 A7 L.9 A7 76x32 RA BP-3 BD 42x18 SA 4" HWS 90x34 SA AS-1 4" HWR B-3 K.9 K.9 HWP-3 GF-1 288x96 OA PLENUM ET-1 L M6 M6 B2 A8 144x84 OA PLENUM B2 A8 L-1 M A8 N K L.9 M ENLARGED MECHANICAL MEZZANINE - HVAC PLAN SCALE: 1/4" = 1'-0" L L.1 N N.1 2 ENLARGED MAINTENANCE MEZZANINE - HVAC PLAN SCALE: 1/4" = 1'-0" L.9 M 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: 3123 CHECKED BY: Checker ENLARGED MECHANICAL PLANS 4/1/2013 10:38:06 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt 1 L.1 NOT FOR CONSTRUCTION B1 B1 L DESIGN DEVELOPMENT HWP-1 JACKSON, WYOMING 38x28 EA SWH-2 A5 1 1/4" HWR 3" HWR 3" HWS 1 1/4" HWS 2" HWS/R DN SA M-401 H H H JJJ H.3 H.3 H.5 K K K J.5 M4 M5 M4 M4 M5 M5 T.O. PARAPET (DRIVE AISLE) 135' - 0" 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f H.3 T.O. PARAPET (DRIVE AISLE) 135' - 0" DRIVE AISLE BOTTOM OF DECK 133' - 0" T.O. PARAPET 124' - 0" MANUAL VOLUME DAMPER TYPICAL OF ALL BRANCH DUCTS IN MAINTENANCE ZONE MANUAL VOLUME DAMPER, TYPICAL OF ALL SUPPLY BRANCH TAKEOFFS IN MAINTENANCE ZONE MAINTENANCE MEZZANINE 119' - 10" T.O. PARAPET 124' - 0" m GR UP e d e s i g n MAINTENANCE MEZZANINE 119' - 10" 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: Level 2 (RESIDENTIAL) 110' - 0" DIFFUSER www.megroup.com Job #: 755.011 DIFFUSER High Performance Building Consultants LEVEL 1 100' - 0" LEVEL Level11 0" 100'100'- -0" T.O Footing 96' - 0" SCALE: 1/8" = 1'-0" DESIGN DEVELOPMENT 2 JACKSON, WYOMING SCALE: 1/8" = 1'-0" SINGLE GRILLE SUPPLY DROP DETAIL TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 1 DUAL GRILLE SUPPLY DROP DETAIL NOT FOR CONSTRUCTION 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker MECHANICAL DETAILS 4/1/2013 10:38:07 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: M-501 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f HANGER ROD SCHEDULE PIPE SIZE ROD SIZE PIPE SIZE ROD SIZE UP TO 2" 3/8" DIA. 4" - 5" 5/8" DIA. 2 1/2 - 3" 1/2" DIA. 6" - 12" 7/8" DIA. HANGER ROD HANGER ROD LOCKING NUT LOCKING NUT HEAVY DUTY CLEVIS HANGER 3"x3"x3/16" ANGLE WELDED TO BAR JOISTS AIR OUT OUT VAPOR BARRIER INSULATION FLANGED CONNECTION ON SIDE WASHER 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: 1 1/2" MIN. TO 3" MAX. INSTALLED 6" NORMAL W/ MATERIAL TAUT www.megroup.com Job #: 755.011 High Performance Building Consultants NOTES: 1. COORDINATE ALL CONNECTIONS TO BUILDING STRUCTURE WITH STRUCTURAL ENGINEER PRIOR TO INSTALLATION. 2. ALL-THREAD ROD AND ANGLE SIZING ARE FOR REFERENCE ONLY. CONTRACTOR SHALL VERIFY SIZING WITH ACTUAL EQUIPMENT BEING INSTALLED. TYPICAL PIPE SUPPORT 2 SCALE: NO SCALE AIR SEPARATOR TYPICAL FLEXIBLE DUCT CONNECTIONS 3 SCALE: NO SCALE SCALE: NO SCALE DISCHARGE PIPE LOW VELOCITY RECTANGULAR DUCT SUCTION PIPE EXHAUST FAN, SEE SCHEDULE FOR CAPACITY AND CONFIGURATION. BUTTERFLY VALVE NON SLAM CHECK VALVE PRESSURE GAUGE INSULATED FLEXIBLE DUCT. 5'-0" MAXIMUM SPRING ISOLATOR 1/4" NEOPRENE GASKET BETWEEN DUCT AND FAN FLEXIBLE CONNECTOR SUCTION DIFFUSER WITH STRAINER ISOLATION FRAME CONCRETE PAD SECURE EXHAUST FAN TO PREFABRICATED INSULATED ROOF CURB EXTEND DUCTWORK OVER TOP OF CURB, SECURE DUCTWORK TO CURB NAILER CURB WITH TREATED WOOD NAILER PROVIDED BY FAN MANUFACTURER SECURE CURB TO ROOF WITH SCREWS, PINS, OR BOLTS INERTIA PAD INSULATION SQUARE TO ROUND ADAPTER (WHERE APPLICABLE) SHEET METAL BAND CONICAL TRANSITION TAKE-OFF ACOUSTICAL TILE CEILING VOLUME DAMPER NOTES: 1. ACOUSTICAL TILE CEILING SHOWN. GYP. BOARD CEILING SIMILAR. NOTES: 1. BASED MOUNTED PUMP PIPING SHOWN. CLOSED COUPLE PUMP SIMILAR. 2. OMIT ISOLATION FRAME FOR CLOSED COUPLE PUMP. BOLT PUMP DIRECTLY TO CONCRETE PAD. 3. PROVIDE PRESSURE TEMPERATURE TAPS IN PUMP INLET & PUMP DISCHARGE FLANGES ROOF OPENING AND ANGLE IRON FRAME, FASTEN SECURELY TO ROOF AND DUCTWORK ROOF DECK COUNTER BALANCED BACKDRAFT DAMPER FACTORY INSTALLED IN ROOF CURB 5 6 SCALE: NO SCALE R HW PRESSURE GAGE & SIPHON BASE MOUNTED PUMP DETAIL 7 SCALE: NO SCALE EXHAUST FAN DETAIL SCALE: NO SCALE S TO SYSTEM PRESSURE SWITCH VIBRATION ISOLATORS (TYP.) BALANCING VALVE PRESSURE GAUGE FULL-SIZE DISCHARGE PIPE FROM SYSTEM RELIEF VALVE GAGE COCK (TYP.) THERMOMETER WELL (TYP.) MANUAL AIR VENT THERMOMETER SHUT-OFF VALVE CHECK VALVE CHEMICAL FEEDER CHECK VALVE BALANCING VALVE S HW TAPS FOR PRESSURE GAUGE (TYP.) BALL VALVE (TYP.) W LO F AIR DESIGN DEVELOPMENT SCALE: NO SCALE TYPICAL ROUND FROM RECTANGULAR TAKE−OFF DETAIL JACKSON, WYOMING TYPICAL CEILING DIFFUSER DETAIL TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY LOW VELOCITY ROUND BRANCH DUCT 1/2" 4 m GR UP e d e s i g n SHEET METAL AS SPECIFIED FOR DUCTWORK SHEET METAL AS SPECIFIED FOR DUCTWORK SINGLE HORIZONTAL RUNS WITH VAPOR BARRIER INSULATION SINGLE HORIZONTAL RUNS NO VAPOR BARRIER INSULATION FLEXIBLE MATERIAL SPECIFIED 1 1/2" POCKET SLIP DUCT DRAIN VALVE WITH HOSE CONNECTION 16 GAGE ZINC COATED SHEET STEEL SADDLE SHIELD AT LEAST 12" LONG 1 BOLT ON 4" CENTER CLEVIS HANGER ADJUST SO TANK MAY BE REMOVED FROM LINE. (TYPICAL) WATER SUPPORT NUT INSULATION WHERE SPECIFIED SHALL BUTT AGAINST PIPE HANGERS UNION 1" FLANGE & HEM IN SUPPORT NUT PIPE 1"x1/8" BAND IRON WATER 1/2" ALLTHREADED ROD HEAVY DUTY CLEVIS HANGER 1 1/4" TO EXPANSION TANK UNION (TYP.) CONTROL VALVE (ADJ. TO REGULATE CHEMICAL FEED). GATE VALVE (TYP.) DRAIN VALVE W/ 3/4" HOSE CONNECTION FLOOR BALANCING VALVE UNION (TYP.) CHECK VALVE UNION LOW WATER/GLYCOL MIX CUT-OFF SWITCH STORAGE DRUM W/ LID STRAINER W/ DRAIN VALVE & 3/4" HOSE CONNECTION PUMP NOT FOR CONSTRUCTION 1/2" FROM SYSTEM 4" CONCRETE PAD 8 UNIT HEATER − HOT WATER SCALE: NONE 9 INLINE PUMP DETAIL 11 SCALE: NONE 10 CHEMICAL FEEDER SCALE: NO SCALE DRAIN VALVE W/ HOSE CONNECTION GLYCOL FEEDER ASSEMBLY SCALE: NONE 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker MECHANICAL DETAILS 4/1/2013 10:38:08 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: M-502 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f CONCRETE SLAB EXPANSION JOINT m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants SLAB INSULATION, TYP. WIRE MESH, REBAR OR STAPLE TO RIGID FOAM WIRE TIE RADIANT TUBING, TYP. SUB SOIL DESIGN DEVELOPMENT JACKSON, WYOMING SCALE: NO SCALE TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 1 RADIANT FLOOR DETAIL NOT FOR CONSTRUCTION 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker MECHANICAL DETAILS 4/1/2013 10:38:09 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: M-503 MARK SERVES MANUF. & WEIGHT LxWxH (IN) (LBS) SUPPLY FAN INFORMATION RETURN FAN INFORMATION AHU SECTION MODEL OR EQUAL AHU-1 DIMENSIONS TRANE TYPE CFM RPM B.H.P. HP MIN. MIN. E.S.P. OUTSIDE AIR " wg. (CFM) TYPE CFM EVAP COOLING COIL RPM B.H.P. HP HW HEATING COIL MIN. MAX. COIL CAPACITY EAT LAT MAX. COIL E.S.P. FACE VEL. TOTAL SENS. (DEG F) (DEG F) FACE VEL. " wg. (FPM) (MBH) (MBH) DB WB DB WB (FPM) 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f AIR HANDLING UNIT SCHEDULE ELECTRICAL DATA OUTPUT EAT LAT EWT LWT GPM CAPACITY MCA MOPD V/PH/HZ (MBH) FANS OFFICE/ADMIN 205x80x67 4113 AF 12000 1725 11.186 15 3.0 1800 PLENUM 12000 1725 10.167 15 2.0 498 302.88 302.86 84.1 55.2 55 43.9 481 45 55 140 120 11.3 104 47.69 68.69 460/3/60 LIGHT CIRCUIT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3.26 5.87 120/1/60 POWER RECEPTACLE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10.00 18.00 120/1/60 NOTES: 1. PROVIDE ROOF TOP UNIT WITH NATURAL GAS HEATING COIL, 2" FILTERS, SERVICE OUTLET, SINGLE POINT ELECTRICAL CONNECTION, ROOF CURB, DUCT SMOKE DETECTORS, AND PHASE AND BROWN OUT PROTECTION. 2. UNIT SELECTED AT 6300 FT. ABOVE SEA LEVEL. 3. HW TEMPERATURES ARE 140ºF EWT, 110ºF LWT, 40% PROPYLENE GLYCOL. 4. DX COOLING COILREFRIGERANT TYPE IS R-410A. m GR UP e d e s i g n ENERGY RECOVERY VENTILATOR SCHEDULE MARK WHEEL HP WHEEL AIR TEMPS (DEG. F) FAN INFORMATION HP RETURN MIN E.S.P. AIR CFM "WG 3.5 (2) 15 (2) 12,395 3.0 (2) 15 3.5 (4) 15 (4) 13,500 3.0 (4) 15 (1) 15 (1) 11,000 1.5 1,710 SERVES LOCATION SUPPLY MIN E.S.P. AIR CFM "WG ERV-1 BUS STORAGE MECH MEZZ (2) 13,000 ERV-2 MAINTENANCE MAINT MEZZ (4) 13,500 (1) 11,000 ERV-3 RESIDENTIAL ROOF RESIDENTIAL WING 1,900 0.75 HP EAT SUMMER HP DB DB WB EFFICIENCY ELEC DATA HEAT LAT LAT SUMMER/ FLOW DB (F) DB (F) WINTER (GPM) EWT LWT (FT) 48.47 140 109 140 140 LAT WINTER WB HW COIL PREHEAT WPD ARRANGEMENT OA INTAKE SA DISCHARGE RA INTAKE EA DISCHARGE POSITION POSITION POSITION POSITION WxLxH (IN) (LBS) FRONT TOP 143x250x137 13,700 1,6,8 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: FRONT FRONT TOP 15,290 2,6,8 www.megroup.com BOTTOM BOTTOM SIDE 2,000 3,5,8 V/PH/HZ MCA MOCP 10 460/3/60 83 100 SIDE FRONT 109 10 460/3/60 186 200 BACK 109 10 208/3/60 80.3 90 FRONT DIMENSIONS WEIGHT NOTES: (1) 15 0.75 1.5 NA 30.0 53x101x53 Job #: 755.011 NOTES: 1. PROVIDE ENERGY RECOVERY VENTILATOR EQUAL TO ANNEX AIR MODEL XXX WITH ENERGY RECOVERY WHEEL, MOTORIZED OUTDOOR AND EXHAUST AIR DAMPER, CO2 SENSOR, DIRTY FILTER SENSORS, MERV 8 PRE- AND MERV 13 FINAL FILTERS. 2. PROVIDE ENERGY RECOVERY VENTILATOR EQUAL TO ANNEX AIR MODEL XXX WITH ENERGY RECOVERY WHEEL, MOTORIZED OUTDOOR AND EXHAUST AIR DAMPER, CO2 SENSOR, DIRTY FILTER SENSORS, MERV 8 PRE- AND MERV 13 FINAL FILTERS. 3. PROVIDE ENERGY RECOVERY VENTILATOR EQUAL TO VENMAR HRV. 4. PROVIDE WITH EVAPORATIVE COOLING, ELECTRIC PREHEAT, HW HEAT, EXHAUST DISCHARGE GRAVITY BACKDRAFT DAMPER, BIRDSCREEN, VFDS ON SUPPLY AND EXHAUST FANS, AND DISCONNECT. 5. OUTSIDE AIR DESIGN TEMPS ARE 84/59 DEG F DB/WB SUMMER AND -15 DEG F. WINTER. EXHAUST AIR TEMPS ARE 75/62 DEG F. DB/WB SUMMER AND 72/55 DEG F. DB/WB IN WINTER. 6. OUTSIDE AIR DESIGN TEMPS ARE 84/59 DEG F DB/WB SUMMER AND -15 DEG F. WINTER. EXHAUST AIR TEMPS ARE 84/55 DEG F. DB/WB SUMMER AND 50 DEG. F. DB WINTER. 7. PROVIDE ERV WITH EVAPORATIVE COOLING SECTION. 8. ALL ERV SELECTIONS ARE AT AN ELEVATION OF 6237 FT. LOUVER SCHEDULE PUMP SCHEDULE MAX VEL @ MIN FREE PUMP HEAD SIZE AIRFLOW FREE AREA AREA MARK MODEL OR EQUAL SERVES TYPE LOCATION GPM EFFIC. (FT.) RPM BHP HP VOLTS/PH/HZ (LBS) NOTES: (WxH INCH) (CFM) (FPM) (SQ FT) HWP-1 BELL & GOSSET 1510 1-1/2 BC HEATING HOT WATER BASE MOUNTED-END SUCTION BOILER ROOM 110 62.4% 80 1750 3.59 5 460/3/60 210 1,2,3,4,5,6 144x84 38000 823 46.18 HWP-2 BELL & GOSSET 1510 1-1/2 BC HEATING HOT WATER BASE MOUNTED-END SUCTION BOILER ROOM 110 62.4% 80 1750 3.59 5 460/3/60 210 1,2,3,4,5,6 REFER TO ARCH 288x96 65000 783 82.97 HWP-3 BELL & GOSSET 1510 1-1/2 BC HEATING HOT WATER (FUTURE) BASE MOUNTED-END SUCTION BOILER ROOM 110 62.4% 80 1750 3.59 5 460/3/60 210 1,2,3,4,5,6 REFER TO ARCH 84x72 18000 785 22.94 BP-1 BELL & GOSSET 80 3X3X7B BOILER PUMP INLINE BOILER ROOM 118 67.5% 20 1750 0.89 1 208/3/60 78 1,2,5,6 1.16 BP-2 BELL & GOSSET 80 3X3X7B BOILER PUMP INLINE BOILER ROOM 118 67.5% 20 1750 0.89 1 208/3/60 78 1,2,5,6 BP-3 BELL & GOSSET 80 3X3X7B BOILER PUMP (FUTURE) INLINE BOILER ROOM 118 67.5% 20 1750 0.89 1 208/3/60 78 1,2,5,6 MARK MANUFACTURER MODEL SERVES FINISH L-1 GREENHECK EDD-601 ERV-1 & AHU-1 OA INTAKE REFER TO ARCH L-2 GREENHECK EDD-601 ERV-2 OA INTAKE L-3 GREENHECK EDD-601 CNG BUILDING INTAKE L-4 GREENHECK L-5 L-6 NOTES: High Performance Building Consultants EDD-601 WASH EQUIP/COMPRESSOR REFER TO ARCH 18x24 840 724 GREENHECK EDD-601 ELEC SWITCH GEAR REFER TO ARCH 36x30 2545 753 3.38 GREENHECK EDD-601 ELECTRICAL STORAGE CNG REFER TO ARCH 30x18 1070 863 1.24 MANUFACTURER& MOTOR WEIGHT NOTES: 1. PROVIDE WITH BIRDSCREEN ON OUTSIDE OF LOUVER. 2. PROVIDE WITH MOTORIZED DAMPER TO INTERLOCK WITH FAN. 1. PROVIDE ALL PIPING ACCESSORIES AS PER PUMP PIPING DETAIL. 3. COORDINATE EXACT LOCATION AND BLANK OFF OF EXISTING WITH ARCHITECTURAL. 2. PROVIDE VARIABLE FREQUENCY DRIVE WITH ISOLATION BYPASS AND INTEGRAL DISCONNECT SWITCH. 4. PROVIDE WITH BIRDSCREEN ON INSIDE OF LOUVER FOR CLEANING. 3. PROVIDE WITH NEMA PREMIUM EFFICIENCY MOTOR. 4. PROVIDE WITH 4" HOUSEKEEPING PAD AND GROUTED BASE. 5. PROVIDE PUMP SELECTION FOR 40% PROPYLENE GLYCOL. BOILER SCHEDULE OUTPUT OUTPUT @ FLOW (MBH) (MBH) SITE (MBH) (GPM) 2,500 2,375 1,775 118 NG 2,500 2,375 1,775 118 NG 2,500 2,375 1,775 118 FUEL PATTERSON KELLY C2500 HW SYSTEM NG B-2 PATTERSON KELLY C2500 HW SYSTEM B-3 PATTERSON KELLY C2500 HW SYSTEM (FUTURE) MODEL OR EQUAL EWT DIMENSIONS WEIGHT LxWxH (IN) (LBS) 58x32x79 1600 1,2,3,4 120/1/60 58x32x79 1600 1,2,3,4 120/1/60 58x32x79 1600 1,2,3,4 LWT WATER VOL. WPD V/PH/HZ F F (GAL.) PSI 110 140 19 4 120/1/60 110 140 19 4 110 140 19 4 NOTES: NOTES FAN SCHEDULE MARK MANUFACTURER MODEL SERVES TYPE CFM ESP (IN WC) MOTOR (HP) MOTOR (RPM) DRIVE BACKDRAFT DAMPER WEIGHT VOLT/PH/HZ NOTES 1. PROVIDE CONDENSING GAS BOILER WITH BOILER CIRULATION PUMP AND ISOLATION VALVES. 2. PROVIDE WITH VENTLESS GAS REGULATOR AND EMERGENCY POWER OFF SWITCH. EF-1 GREENHECK G-103HP-VG ADMIN RESTROOMS CENTRIFUGAL DOWNBLAST 775 0.50 1/2 2500 DIRECT NONE 52 115/1/60 1,2 3. SELECT BOILER FOR SITE ELEVATION = 6,300 FT ABOVE SEA LEVEL BASED ON 4% DERATE/1,000 FT ELEV. EF-2 GREENHECK G-098-A MAINTENANCE RESTROOMS CENTRIFUGAL DOWNBLAST 560 0.50 1/4 1725 DIRECT NONE 46 115/1/60 1,2 4. PROVIDE WITH VENT/FLUE KIT AND CONDENSATE NEUTRALIZATION KIT. EF-3 GREENHECK CW-065-VG BATTERY STORAGE SIDEWALL CENTRIFUGAL 200 0.25 1/6 1725 DIRECT NONE 36 115/1/60 1 EF-4 - EF-15 BROAN XB-80 RESIDENTIAL RESTROOMS CEILING EXHAUST 80 0.25 7.6W - DIRECT GRAVITY 22 115/1/60 3,4 EF-16 GREENHECK G-103-A CNG- COMPRESSOR ROOM CENTRIFUGAL DOWNBLAST 1300 0.50 1/3 1725 DIRECT GRAVITY 46 115/1/60 5 EF-17 GREENHECK CW-161-B ELEC SWITCH GEAR CENTRIFUGAL SIDEWALL 2545 0.25 1/2 1725 DIRECT GRAVITY 92 208/3/60 EF-18 GREENHECK G-099-A ELECTRICAL STORAGE CNG CENTRIFUGAL DOWNBLAST 1070 0.25 1/4 1725 DIRECT NONE 53 115/1/60 TF-1 GREENHECK SQ-100-A WASH/EQUIP COMPRESSOR CENTRIFUGAL INLINE 840 0.25 1/4 1725 DIRECT NONE 58 115/1/60 RADIANT HEAT MANIFOLD SCHEDULE DESIGN AREA HEATING HEATING FLOW COVERED LOAD LOAD MANIFOLD NO. SERVES (GPM) (FT²) MBH (BTH/SF) RHM-1 BUS PARKING 15.2 3686 136 36.8 RHM-2 BUS PARKING 15.0 3631 134 36.8 1. ALL CAPACITIES ARE SIZED AT 6,237 FT. RHM-3 BUS PARKING 14.5 3513 129 36.8 2. PROVIDE WITH MANUFACTURER'S ROOF CURB. RHM-4 BUS PARKING 17.2 4166 153 36.8 3. PROVIDE WITH WALL CAP AND GRAVITY DAMPER. RHM-5 BUS PARKING 16.9 4103 151 36.8 RHM-6 BUS PARKING 16.4 3970 146 36.8 RHM-7 DRIVE AISLE 16.1 3894 143 36.8 RHM-8A DRIVE AISLE 12.8 3107 114 36.8 RHM-8B DRIVE AISLE 12.8 3107 114 36.8 RHM-9A DRIVE AISLE 15.4 3734 137 36.8 RHM-9B DRIVE AISLE 15.4 3734 137 36.8 RHM-10 WASH BAY 15.3 3717 137 36.8 5 NOTES: 4. INTEGRATE WITH ROOM LIGHT SWITCH. 5. PROVIDE AS SPARK RESISTANT CONSTRUCTION, AND EXPLOSION PROOF: GREENHECK TYPE A. HOT WATER UNIT HEATER SCHEDULE MARK MANUFACTURER MODEL SERVES TYPE CFM MBH GPM MOTOR (W) VOLT/PH/HZ NOTES RHM-11 MAINTENANCE AREA 11.9 2883 106 36.8 RHM-12 MAINTENANCE AREA 13.2 3211 118 36.8 UH-1 TRANE S-A08 WASH EQUIP/COMPRESSOR VERTICAL 245 5.2 0.8 16W 120/1/60 1,2 RHM-13A MAINTENANCE AREA 14.2 3444 127 36.8 UH-2 TRANE S-A08 WASH EQUIP/COMPRESSOR VERTICAL 245 5.2 0.8 16W 120/1/60 1,2 RHM-13B MAINTENANCE AREA 14.2 3444 127 36.8 UH-3 TRANE S-A08 WATER ENTRY VERTICAL 245 5.2 0.8 16W 120/1/60 1,2 RHM-14A MAINTENANCE AREA 10.9 2645 97 36.8 RHM-14B MAINTENANCE AREA 10.9 2645 97 36.8 RHM-15A MAINTENANCE AREA 8.7 2100 77 36.8 RHM-15B MAINTENANCE AREA 10.8 2621 96 36.8 RHM-16 MAINTENANCE AREA 8.9 2156 79 36.8 286.8 69511 2559 36.8 BUILDING SYSTEM TOTAL: NOTES: 1. CAPACITIES ARE AT 6237 FT. 2. HEATING CAPACITIES ARE BASED ON 100% WATER, 140°F EWT, 110°F LWT, 60°F EAT. ROOF HOOD SCHEDULE MARK MANUFACTURER & GENERAL NOTES 1. HEATING WATER: EWT=140F, 30F TEMPERATURE DIFFERENTIAL. 2. CONTRACTOR TO VERIFY LOOP LENGTHS PRIOR TO INSTALLATION. 3. BALANCE MANIFLODS ACCORDING TO MANUFATURER'S RECOMMENDATIONS. 4. 5/8", HEPEX TUBING INSTALLED IN CONCRETE SLAB, REFER TO SPECIFICATION 238316. SERVES LOCATION CFM A.P.D. AREA VELOCITY (SQ. FT.) MODEL OR EQUAL SIZE WEIGHT LxWxH (IN) (LBS) NOTES RH-1 GREENHECK FGR ERV-1 EA DISCHARGE ROOF 26000 0.1 35.75 727 111x99x29.5 530 1 RH-2 GREENHECK FGR AHU-1 RELIEF ROOF 15000 0.1 19.25 779 87x70x23 169 1 RH-3 GREENHECK FGR ERV-2 DISCHARGE ROOF 65000 0.1 78 833 195x121x36.5 266 1 RH-4 GREENHECK FGR NG COMPRESSOR RELIEF ROOF 18000 0.1 22.5 800 111x64x19 244 RH-5 GREENHECK FGR NG COMPRESSOR RELIEF ROOF 18000 0.1 22.5 800 111x64x19 244 5. MANIFOLDS SHALL BE UPONOR CLASSIC ASSEMBLY WITH BALANCING AND ISOLATION VALVES DESIGN DEVELOPMENT B-1 INPUT SERVES JACKSON, WYOMING MANUFACTURER & TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY MARK 6. PUMP IS SIZED FOR 100% OF FLOW AND SHALL BE SELECTED TO OPERATE IN LEAD/LAG PUMPING SYSTEM. NOTES: 1. PROVIDE WITH BIRDSCREEN, ROOF CURB, AND BACKDRAFT DAMPER. VAV BOX SCHEDULE MARK MANUFACTURER MODEL SERVES INLET ("Ø) MIN (CFM) MAX (CFM) MBH GPM VAV-01 PRICE SPV DIRECTOR 155 6 105 350 10.9 0.73 VAV-02 PRICE SPV BREAK/COPY 156 6 67.5 225 7.0 0.47 VAV-03 PRICE SPV OFFICE 157,159 8 124.5 415 12.9 0.86 VAV-04 PRICE SPV LOBBY 1ST FLOOR 16 668.1 2227 69.4 4.62 VAV-05 PRICE SPV LOCKERS 207 6 60 200 6.2 0.42 VAV-06 PRICE SPV LOBBY 2ND FLOOR 16 906 3020 94.1 6.27 VAV-07 PRICE SPV TRAINING 207 16 709.5 2365 73.7 4.91 VAV-08 PRICE SPV BOOKKEEPING 213A 6 99 330 10.3 0.69 VAV-09 PRICE SPV QUIET 210, 211 8 138 460 14.3 0.96 VAV-10 PRICE SPV HALL 206 8 195 650 20.2 1.35 VAV-11 PRICE SPV SUPERS 213 12 405 1350 42.1 2.80 1 DESIGN DEVELOPMENT 4/18/13 VAV-12 PRICE SPV DRIVERS 213 16 900 3000 93.5 6.23 No REVISION/SUBMISSION DATE VAV-13 PRICE SPV BREAK 214 8 150 500 15.6 1.04 COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. VAV-14 PRICE SPV FARE ROOM 164 6 45 150 4.7 0.31 PROJECT No: CHECKED BY: Checker 1. ALL CAPACITIES ARE AT 6237 FT. 2. HEATING COIL CAPACITIES BASED ON 100% WATER, 140°F EWT, 110°F LWT, 55°F EAT, 85°F LAT, AND MAXIMUM CFM. 4/1/2013 10:38:10 AM D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt NOTES: DRAWN BY: Author NOT FOR CONSTRUCTION 3123 MECHANICAL SCHEDULES M-601 FINNED TUBE BASEBOARD HEATER SCHEDULE MARK MANUFACTURER MODEL SERVES MBH/SF GPM ELEMENT LENGTH (FT-IN) BBH-1 VULCAN LC-209 RESIDENTIAL AND RESTROOMS 1.14 4 CAB LENGTH - 6" CABINET LENGTH (FT-IN) FIN SIZE ("H x "W) PIPE SIZE ("Ø) FINS LF WPD LF NOTES SEE PLANS 10-11/16"x3-1/8" 1-1/4" 50 NA 1,2 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f NOTES: 1. ALL CAPACITIES ARE AT 6621 FT 2. HEATING CAPACITIES BASED ON 100% WATER, 140°F EWT, 110°F LWT, 60°F EAT. GRILLE, REGISTER, & DIFFUSER SCHEDULE MARK MANUFACTURER MODEL FACE NECK SIZE SIZE MATERIAL DESCRIPTION FRAME TYPE COLOR SD-1 PRICE SCD 24x24 SEE PLANS STEEL 3-CONE LOUVERED FACE LAY-IN WHITE SG-1 PRICE 520 NECK + 2-1/2" SEE PLANS ALUMINUM 3/4" SPACING ADUSTABLE LOUVER SURFACE WHITE SG-2 PRICE LBPH 26C 4" SEE PLANS ALUMINUM 15 DEG DEFLECTION 7/16" SPACING BAR GRILLE SURFACE WHITE SG-3 PRICE SDGE NECK + 2" SEE PLANS ALUMINUM DOUBLE DEFLECTION DUCT GRILLE SURFACE WHITE RG-1 PRICE PDDR 24"x24" SEE PLANS STEEL PERFORATED FACE DUCTED RETURN LAY-IN WHITE RG-2 PRICE 535 NECK + 2-1/2" SEE PLANS ALUMINUM 1/2" SPACING 45 DEG. FIXED LOUVER SURFACE WHITE EG-1 PRICE PDDR 24x24 SEE PLANS ALUMINUM PERFORATED FACE DUCTED RETURN LAY-IN WHITE NOTES m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: 1 NOTES: 1. PROVIDE WITH O.B.D. www.megroup.com Job #: 755.011 High Performance Building Consultants EXPANSION TANK SCHEDULE MARK MANUFACTURER MODEL ET-1 SERVES TYPE HYDRONIC HOT WATER VERTICAL TANK ACCEPTANCE CHARGE VOLUME VOLUME PRESSURE DIMENSIONS WEIGHT (GALLONS) (GALLONS) (PSI) ("Ø x "H) (LBS) NOTES NOTES: 1. AIR/HYD SEPARATOR SCHEDULE SERVES MARK AS-1 MANUFACTURER MODEL SPIROTHERM SPIROVENT VDN600 GPM HEATING WATER MAX PD OPENINGS (FT HD) (IN.) 5 6 180 NOTES 1 NOTES: 1. PROVIDE WITH REMOVABLE STRAINER. ELECTRIC UNIT HEATER SCHEDULE MARK SERVES E.A.T. L.A.T (DEG. F) (DEG. F) CNG-COMPRESSOR ROOM 45 85 UHXA-05 CNG-ELECTRICAL/STORAGE 45 TRANE UHXA-15 CNG-OFFICE EUH-4 TRANE UHXA-05 EUH-5 TRANE EUH-6 TRANE MANUFACTURER MODEL EUH-1 TRANE UHXA-05 EUH-2 TRANE EUH-3 KW FAN INFORMATION ELEC. INFORMATION NOTES CFM H.P. VOLTS/PH/HZ 15 580 1/4 480/3/60 1 85 5 580 1/4 480/3/60 1 45 85 5 2450 1/2 480/3/60 1 VESTIBULE 162 45 85 5 580 1/4 480/3/60 UHXA-05 ELEC EQUIP 168 45 85 5 580 1/4 480/3/60 UHXA-05 ELEC SWITCH GEAR 169 45 85 5 580 1/4 480/3/60 NOTES: 1. ELECTRIC UNIT HEATERS TO BE EXPLOSION PROOF. 2. PROVIDE WITH FACTORY INSTALLED DISCONNECT SWITCH. GAS UNIT HEATER SCHEDULE MARK MANUFACTURER MODEL SERVES MBH MBH CAPACITY INPUT OUTPUT (MBH) FAN INFORMATION MOTOR HP CFM VOLTS/PH/HZ GUH-1 MODINE PTC-110 WASH BAY 110 85.9 110 1/3 1750 208/3/60 GUH-2 MODINE PTC-110 CHASSIS WASH 110 85.9 110 1/3 1750 208/3/60 NOTES: 1. MOUNT AT 13' AFF. 2. PROVIDE WITH VERTICAL CONCENTRIC VENT KIT AND MOTOR PROTECTION CAGE. 2. UNIT DERATED FOR AN ALTITUDE OF 6237 FT. GLYCOL FEED TANK SIZE (GAL) HP VOLT/PH/HZ NOTES GF-1 L.J. WINGERT HYDRONIC 50 1/3 120/1/60 1 NOTES: 1 50 GALLON POLYETHYLENE TANK WITH 1/3" HINGED PE COVER, CARBON STEEL BOTTOM MOUNT STAND, NEMA 4X CONTROL PANEL W/ 115V CORD. LOW LEVEL SWITCH, 1/3 HP GEAR PUMP, PUMP CONTROLLED BY BMS, "PUMP" UNDER TANK WITH AGITATOR. DESIGN DEVELOPMENT MOTOR SERVES JACKSON, WYOMING TANK MODEL OR EQUAL TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY MANUFACTURER & MARK NOT FOR CONSTRUCTION 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker MECHANICAL SCHEDULES 4/1/2013 10:38:11 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: M-602 NOTE: UPPER CASE LETTER DENOTES LUMINAIRES TYPE. LOWER CASE LETTER ADJACENT TO LUMINAIRE INDICATES SWITCH THAT CONTROLS LUMINAIRES PANELBOARD, ELECTRICAL DISTRIBUTION PANEL, OR LOAD CENTER RECESS MOUNTED ONE LINE AND RISER ABBREVIATIONS A 2' X 4' RECESSED FLUORESCENT LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. A 2' X 4' SURFACE MOUNTED FLUORESCENT LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. 20 AMP, 125V, NEMA 5-20R DUPLEX RECEPTACLE PANEL XXX 20 AMP, 125V, NEMA 5-20R QUAD RECEPTACLE PANEL 20 AMP, 125V, NEMA 5-20R DUPLEX RECEPTACLE, MOUNTED 6" ABOVE COUNTER AND/OR ABOVE BACKSPLASH, UNLESS OTHERWISE NOTED 20 AMP, 125V, NEMA 5-20R SWITCHED DUPLEX RECEPTACLE CURRENT TRANSFORMER, RATED AS SPECIFIED OR REQUIRED A 2' X 2' RECESSED FLUORESCENT LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. A 2' X 2' SURFACE MOUNTED FLUORESCENT LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. 20 AMP, 125V, NEMA 5-20R DUPLEX FLOOR RECEPTACLE, 3/4" CONDUIT RUN CONCEALED IN FLOOR SLAB MOTOR M TVSS 20 AMP, 125V, NEMA 5-20R QUAD FLOOR RECEPTACLE, 3/4" CONDUIT RUN CONCEALED IN FLOOR SLAB TRANSIENT VOLTAGE SURGE SUPPRESSION A GROUND CONNECTION J JUNCTION BOX, FLOOR/CEILING MOUNTED J JUNCTION BOX, WALL MOUNTED 800A3P SWITCH, RATING AS SHOWN 1' X 4' RECESSED FLUORESCENT LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. A 1' X 4' SURFACE MOUNTED FLUORESCENT LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. FUSE, FUSE AMPACITY AND TYPE AS SHOWN SPECIAL RECEPTACLE, WALL MOUNTED, CONFIGURATION AS NOTED ON PLAN A 1' X 4' WALL MOUNTED FLUORESCENT LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. A LINEAR PENDANT FLUORESCENT LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. FURNITURE FEED RECEPTACLE, WALL MOUNTED, CONFIGURATION AS NOTED ON PLAN M UTILITY METER (AS REQUIRED BY UTILITY) SAFETY SWITCH, NON-FUSED, 240V, U.N.O. SAFETY SWITCH, NON-FUSED, 240V, U.N.O. FUSED DISCONNECT COMBINATION STARTER/DISCONNECT (SIZE AS INDICATED) T T-XX FURNISHED BY OTHERS FINISHED FLOOR FIRE HOSE CABINET FULL LOAD AMPS FLOOR FULL VOLTAGE, NON REVERSING GD GFI GFR GND GARBAGE DISPOSAL GROUND FAULT CIRCUIT INTERRUPTER (PERSONAL PROTECTION ON DEVICE) GROUND FAULT PROTECTED FROM UPSTREAM GFI RECEPTACLE OR CIRCUIT BREAKER GROUND FAULT RELAY GROUND HOA HPS HSTAT HTG HTR HAND OFF AUTOMATIC HIGH PRESSURE SODIUM HUMIDISTAT HEATING HEATER IG ISOLATED GROUND KCMIL KV KVA KVAR KW KWH 1000 CIRCULAR MILS KILOVOLT KILOVOLT AMPS KILOVOLT AMPS REACTIVE KILOWATT KILOWATT HOUR TRACK LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE LF LRA LINEAR FEET LOCKED ROTOR AMPS CEILING MOUNTED EXIT SIGN. PROVIDE DIRECTIONAL ARROWS AS REQUIRED MATV MBH MCA MCB MCC MD MDP MFR MG MH MSB MTD MW MASTER ANTENNA TELEVISION SYSTEM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPACITY MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MOTORIZED DAMPER MAIN DISTRIBUTION PANEL MANUFACTURER MOTOR GENERATOR MANHOLE MAIN SWITCHBOARD MOUNTED MICROWAVE SINGLE POLE MOUNTED, EXTERIOR LUMINAIRE N/A NIC N/O,N/C N/L NOT APPLICABLE NOT IN CONTRACT NORMALLY OPEN, NORMALLY CLOSED NIGHT LIGHT DOUBLE POLE MOUNTED, EXTERIOR LUMINAIRE OC OV ON CENTER OVEN QUAD POLE MOUNTED, EXTERIOR LUMINAIRE PDO PDU POWER DOOR OPERATOR POWER DISTRIBUTION UNIT PH, ø PIV PJ PNL PT PHASE POST INDICATOR VALVE MOUNTED ON CEILING FOR PROJECTOR PANEL POTENTIAL TRANSFORMER QTY QUANTITY RA RCP REF REV RH RLA RPM RETURN AIR REFLECTED CEILING PLAN REFRIGERATOR REVISION RELATIVE HUMIDITY RUNNING LOAD AMPS REVOLUTIONS PER MINUTE SA SD SF SPDT SPST SP SWBD SUPPLY AIR SMOKE DETECTOR SQUARE FEET SINGLE POLE, DOUBLE THROW SINGLE POLE, SINGLE THROW STATIC PRESSURE SWITCHBOARD TSTAT TL TV TYP THERMOSTAT TWISTLOCK TELEVISION TYPICAL U/F U/G U/S UL UNO UPS UNDERFLOOR UNDERGROUND UNDER SLAB UNDERWRITERS LABORATORIES, INC. UNLESS NOTED OTHERWISE UNINTERRUPTIBLE POWER SUPPLY VAC VAV VM VOLTS ALTERNATING CURRENT, VACUUM VARIABLE AIR VOLUME VENDING MACHINE W/ W/O WP WT WITH WITHOUT WEATHERPROOF WATERTIGHT, WEIGHT XFMR XP TRANSFORMER EXPLOSION PROOF A A FLUORESCENT STRIP TYPE LUMINAIRE, LENGTHS AS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. A SURFACE MOUNTED DOWNLIGHT, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. A RECESSED MOUNTED DOWNLIGHT, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. TRANSFORMER, TYPE AND RATING AS SHOWN COMBINATION DISCONNECT, WITH RECEPTACLE, REFER TO DRAWING FOR SIZE CONDUIT CONNECTION PHOTOCELL G A SINGLE POLE SWITCH; 3= THREE WAY SWITCH, 4= FOUR WAY SWITCH, K= KEY SWITCH, D= DIMMER SWITCH, T0= MOTOR RATED SWITCH, HOA= HAND-OFF-AUTOMATIC CIRCUIT BREAKER WITH GROUND FAULT PROTECTION G CONDUIT CABLE TELEVISION SYSTEM CLOSED CIRCUIT TELEVISION CUBIC FEET PER MINUTE CIRCUIT CEILING COFFEE MAKER COPPER, CONDENSING UNIT FBO FF FHC FLA FLR FVNR FUSED DISCONNECT COMBINATION STARTER/DISCONNECT (SIZE AS INDICATED) C CATV CCTV CFM CKT CLG CM CU EXISTING EMERGENCY POWER OFF EXISTING TO REMAIN PENDANT LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. PLUGMOLD, REFER TO DRAWING FOR LENGTHS BELOW FINISHED FLOOR BREAKER BOTTOM OF STRUCTURE BRITISH THERMAL UNIT (E) EPO ETR MOTOR: HORSEPOWER AS INDICATED ON PLANS OR DIAGRAMS M BFF BKR BOS BTU DIRECT DIGITAL CONTROL DOWN DOUBLE POLE, DOUBLE THROW DOUBLE POLE, SINGLE THROW DISHWASHER DIRECT EXPANSION 800A3P CIRCUIT BREAKER, RATING AS SHOWN AMPS, AIR (COMPRESSED) ABOVE COUNTER ABOVE FINISHED CEILING AREA FOR EVACUATION ASSISTANCE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT AMPERE INTERRUPTING CURRENT ALUMINUM AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE FOR AUDIO VISUAL MEDIA CABINET DDC DN DPDT DPST DW DX SPECIAL RECEPTACLE, CONFIGURATION AS NOTED ON PLAN 400A FRN A AC AFC AFEA AFF AFG AHU AIC AL ATS AWG AV WALL MOUNTED LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. GFP FUSE WITH GROUND FAULT PROTECTION COMMUNICATIONS A WALL WASH LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. GROUND CONNECTION WITH TEST WELL JUNCTION BOX FOR INSTALLATION OF COMMUNICATION OR DATA OUTLET, MOUNTED 18" AFF, UNLESS OTHERWISE NOTED. INSTALL 1" CONDUIT FROM BOX TO 3" INTO ACCESSIBLE LOCATION ABOVE FINISHED CEILING. GROUND ROD A RECESSED STEP LIGHT LUMINAIRE, MOUNTING IS NOTED ON LUMINAIRE SCHEDULE, HATCHING DENOTES FIXTURE SHALL BE PROVIDED WITH EMERGENCY BATTERY BACKUP. POLE MOUNTED UTILITY TRANSFORMER FLOOR JUNCTION BOX FOR INSTALLATION OF COMMUNICATION OR DATA OUTLET. INSTALL 1" CONDUIT FROM BOX CONCEALED IN FLOOR SLAB TO WALL AND TO 3" INTO ACCESSIBLE LOCATION ABOVE FINISHED CEILING. MISCELLANEOUS X JUNCTION BOX FOR INSTALLATION OF TV OUTLET. MOUNTED 18" AFF, UNLESS OTHERWISE NOTED. INSTALL 1" CONDUIT FROM BOX TO 3" INTO ACCESSIBLE LOCATION ABOVE FINISHED CEILING. COORDINATE MOUNTING HEIGHT WITH ARCHITECT PRIOR TO ROUGH-IN. KEY NOTE DESIGNATION X SHORT CIRCUIT TAG DESIGNATION 1 FEEDER TAG DESIGNATION M MICROPHONE OUTLET BOX WITH COVER PLATE, FLOOR MOUNTED, UNLESS OTHERWISE NOTED. REVISION NUMBER DESIGNATION S SPEAKER, CEILING MOUNTED NEW TO EXISTING CONNECTION S SPEAKER, WALL MOUNTED, 84" (CENTERLINE) A.F.F. OR 8" (CENTERLINE) BELOW CEILINGS THAT ARE 8'-0" OR LOWER, UNLESS NOTED OTHERWISE. A A EMERGENCY BATTERY LUMINAIRE (2 HEAD) 84" AFF, UNLESS OTHERWISE NOTED, LETTER DENOTES LUMINAIRE TYPE. A EMERGENCY BATTERY LUMINAIRE (2 HEAD) WITH MOUNTED EXIT SIGN. PROVIDE DIRECTIONAL ARROWS AS REQUIRED MOUNT AT 84" AFF, UNLESS OTHERWISE NOTED. LETTER DENOTES LUMINAIRE TYPE. A X WALL MOUNTED EXIT SIGN. PROVIDE DIRECTIONAL ARROWS AS REQUIRED A NEW CONSTRUCTION EXISTING CONDITIONS DEMOLITION WORK S HORN SPEAKER SC C CONDUIT DESIGNATIONS BRANCH CIRCUITS HOMERUN USE NUMBER 12 AWG WIRE, UNLESS OTHERWISE NOTED. ALL CIRCUITS SHALL CONTAIN A GROUND AND NEUTRAL CONDUCTOR, UNLESS NOTED OTHERWISE. CONTRACTOR SHALL PROVIDE MULTI-WIRE CIRCUIT HANDLE TIES AS FINAL FIELD INSTALLED WIRING REQUIRES. A COMBINATION SPEAKER/CLOCK CLOCK, 84" (CENTERLINE) A.F.F. OR 8" (CENTERLINE) BELOW CEILINGS THAT ARE 8'-0" OR LOWER, UNLESS NOTED OTHERWISE. V A VOLUME CONTROL BOLLARD LUMINAIRE A I INTERCOM MASTER - WALL I INTERCOM MASTER - WALL WITH HANDSET CEILING FAN I I CONDUIT AND WIRE CONCEALED, 3/4" UNLESS OTHERWISE NOTED, CONDUIT USED FOR SWITCH LEGS, AND CONDUIT USED FOR CONTROL WIRING A A H H S A SINGLE POLE SWITCH; 3= THREE WAY SWITCH, 4= FOUR WAY SWITCH, K= KEY SWITCH, D= DIMMER SWITCH, T0= MOTOR RATED SWITCH, HOA= HAND-OFF-AUTOMATIC, P= PILOT LIGHT, O= OCCUPANCY SENSOR LOWER CASE LETTER INDICATES LUMINAIRES CONTROLLED INTERCOM MASTER - DESK WITH HANDSET INTERCOM MASTER - STAFF STATION FIRE ALARM OS FACP FIRE ALARM CONTROL PANEL OS DIRECTIONAL CEILING MOUNTED OCCUPANCY SENSOR FARA FIRE ALARM REMOTE ANNUNCIATOR PANEL OS DUAL DIRECTIONAL CEILING MOUNTED OCCUPANCY SENSOR CEILING MOUNTED OCCUPANCY SENSOR CONDUIT AND WIRE EMBEDDED IN CONCRETE OR BELOW GRADE CONDUIT TURNING DOWN CONDUIT TURNING UP ACP GACP ACCESS CONTROL PANEL GAS ALARM CONTROL PANEL STANDARD MOUNTING HEIGHTS U.N.O. ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS INDICATED ON ELECTRICAL DRAWINGS. SMOKE DETECTOR, ADDRESSABLE PHOTO ELECTRIC CO COMBINATION SMOKE DETECTOR/CARBON MONOXIDE DETECTOR, ADDRESSABLE PHOTO ELECTRIC FD FLAME DETECTOR HD HEAT DETECTOR G GAS DETECTOR DUCT SMOKE DETECTOR, ADDRESSABLE PHOTO ELECTRIC FIRE ADA ALARM STROBE MOUNTED AT 80" AFF OR 6" BELOW CEILING WHICHEVER IS LOWER FIRE ADA ALARM HORN MOUNTED AT 80" AFF OR 6" BELOW CEILING WHICHEVER IS LOWER FIRE ALARM AUDIBLE AND ADA STROBE LIGHT MOUNTED AT 80" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER F FIRE ALARM MANUAL PULL STATION, ADDRESSABLE DOUBLE ACTION CHECKED BY: Checker 4/1/2013 9:49:16 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt MAGNETIC DOOR HOLDER FS FIRE ALARM FLOW SWITCH TS FIRE ALARM TAMPER SWITCH RECEPTACLES (CENTERLINE) RECEPTACLES IN EQUIP. RMS. RECEPTACLES (EXTERIOR) RECEPTACLES (GARAGES) ALARMS, SWITCHES AND CONTROLS (CENTERLINE) TELEPHONE (PUBLIC) TELEPHONE OUTLETS (CENTERLINE) TELEPHONE TERMINAL BOARD (BTM.) SAFETY SWITCHES STARTERS PANELS (TOP) CLOCK OUTLETS (CENTERLINE) FIRE ALARM PULL STATIONS (HANDLE) STROBES (CENTERLINE) FIRE ALARM BELLS (EXTERIOR) CONTROLS (FIRE ALARM CONTROL PANEL) ANNUNCIATION PANELS INTERCOM (AFEA ONLY) REMOTE INDICATING LIGHT (EQUIP. RMS.) REMOTE INDICATING LIGHT (FIN. AREAS) EXIT SIGNS (WALL MOUNTED BTM.) TELEVISION OUTLETS INTERCOMS PHOTOCELLS 18" 48" 24" 24" 48" 1@48" AND 1@36" 18" 6" 48" 48" 72" 90" 44" 80"* 12'-0" 48" 48" 36" 48" CEILING 80" 18" 48" 12'-0" 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK. 2. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED. 3. PROVIDE, WITH SHOP DRAWING SUBMITTAL, 1/4" SCALE LAYOUT DRAWINGS OF ROOMS WITH ELECTRICAL PANEL BOARDS AND TRANSFORMERS. LAYOUTS SHALL SHOW LOCATIONS OF, AND SHALL BE COORDINATED WITH MECHANICAL EQUIPMENT, AND EQUIPMENT SHALL BE DRAWN TO SCALE. 4. RECESSED LIGHT FIXTURES INSTALLED IN GYP. BOARD OR PLASTER CEILINGS SHALL HAVE PLASTER FRAMES INSTALLED PRIOR TO CEILING MATERIAL. 5. FIXTURES RECESSED IN "T-BAR" CEILING SHALL BE SUPPORTED INDEPENDENTLY OF CEILING SYSTEM WITH FOUR #12 HANGER WIRES UP TO STRUCTURE. SECURE HANGER WIRES TO CORNERS OF FIXTURE. CLIP FIXTURE TO GRID ON TWO SIDES WITH FACTORY-FURNISHED CLIPS. FINAL CONNECTION TO FIXTURE SHALL BE MADE WITH A FLEXIBLE UL APPROVED ASSEMBLY. IT IS THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS TO ESTABLISH A STANDARD OF QUALITY. THE ENGINEER RESERVES THE RIGHT TO APPROVE METHODS AND MATERIALS NOT REFLECTED HEREIN. 6. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER-IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK. www.megroup.com Job #: 755.011 7. REVIEW ARCHITECTURAL, STRUCTURAL, AND MECHANICAL DRAWINGS AND PROVIDE LIGHTS, SWITCHES, RECEPTACLES, TELEPHONE OUTLETS, EQUIPMENT CONNECTIONS, ETC. AND ASSOCIATED CIRCUITING IN ALL AREAS, EVEN IF SUCH AREAS ARE NOT SHOWN ON ELECTRICAL DRAWINGS. LAYOUTS, FIXTURE TYPES, QUANTITIES, AND SPACING SHALL BE IN ACCORDANCE WITH SIMILAR AREAS ON THIS PROJECT. CONTRACTOR SHALL INCLUDE COSTS FOR THE ABOVE IN HIS BID. IN ADDITION, CONTRACTOR SHALL PROVIDE LAYOUT DRAWINGS FOR WORK IN SUCH AREAS AND SUBMIT FOR APPROVAL PRIOR TO ROUGH IN. 8. REVIEW ARCHITECTURAL, STRUCTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID. 9. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT/ENGINEER. High Performance Building Consultants 10. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES AND ORDINANCES. 11. PROVIDE PERMITS AND INSPECTIONS REQUIRED. 12. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO OWNER. 13. FIRE ALARM SYSTEM. PROVIDE DEVICES CONDUIT, WIRES, AND CABLE AS DIRECTED BY EQUIPMENT MANUFACTURER. MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL MEET PREVAILING CODES. THE SYSTEM SHALL BE COMPLETE AND OPERABLE IN EVERY RESPECT. SUBMIT SHOP DRAWINGS ACCORDING TO SPECIFICATIONS. SHOP DRAWINGS SHALL INCLUDE A SINGLE LINE DIAGRAM THAT SHOWS DEVICES, CONDUIT, WIRE, CABLE SIZES AND EQUIPMENT TO BE USED. SHOP DRAWINGS SHALL BE STAMPED AND SIGNED BY A REGISTERED ENGINEER PROVIDED BY THE FIRE ALARM VENDOR. SYSTEM CALIBRATION AND TESTING SHALL BE BY FACTORY CERTIFIED TECHNICIAN. 14. WIRE SHALL BE COPPER, 75 DEGREES C RATED FOR GENERAL USE. FOR HID FIXTURES AND WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER, MINIMUM 90 DEGREES C RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREES C AMBIENT. CONDUCTOR AMPACITY SHALL BE DE-RATED FOR HIGHER AMBIENT INSTALLATIONS. 15. PRESENT SHOP DRAWING SUBMITTAL DATA AT ONE TIME, BOUND IN THREE-RING BINDERS, INDEXED IN A NEAT AND ORDERLY MANNER. PARTIAL SUBMITTALS WILL NOT BE ACCEPTED. SUBMITTALS SHALL INCLUDE, BUT NOT BE LIMITED TO LIGHTING FIXTURES, SWITCHGEAR, PANELBOARDS, WIRING DEVICES, SAFETY SWITCHES, FUSES, MOTOR STARTERS, LAMPS, CONDUIT, CONDUIT FITTINGS, AND TRANSFORMERS. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. 17. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS. 18. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC. SHALL BE CONNECTED AND OPERABLE. 19. RECEPTACLES WHICH ARE SHOWN WALL MOUNTED ON THE ELECTRICAL DRAWINGS ON WALLS WHICH, ON THE ARCHITECTURAL DRAWINGS AND ELEVATIONS, ARE SHOWN AS GLASS OR PARTITIONS SHALL BE FLUSH FLOOR DUPLEX RECEPTACLES MOUNTED ADJACENT TO BASE OR WALLS. 20. BOXES FOR TELEPHONE, TV, COMPUTER, WIRING DEVICES, ETC. SHALL BE MINIMUM 4" SQUARE. 21. RECESSED FIXTURES INSTALLED INDOORS SHALL BE THERMALLY PROTECTED. 22. SEE DIVISION 23 DRAWINGS FOR LOCATION OF MECHANICAL EQUIPMENT. PROVIDE SERVICE TO, AND CONNECT EQUIPMENT AS REQUIRED. 23. CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE AND FUSES SHALL BE BUSSMANN. 24. PROVIDE PANELBOARD DIRECTORIES FOR ALL NEW PANELBOARDS INSTALLED UNDER THE SCOPE OF THIS PROJECT. 25. CONDUITS PENETRATING THROUGH ROOF SHALL HAVE ROOF FLASHING WITH CAULK TYPE COUNTER FLASHING SLEEVE. INSTALLATION SHALL BE WATERTIGHT. 26. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS AND OTHER VIBRATING EQUIPMENT SHALL BE WITH SEAL TIGHT FLEX AND APPROVED FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT. 27. WHERE PANELS ARE INSTALLED FLUSH WITH WALLS, EMPTY CONDUITS SHALL BE EXTENDED FROM THE PANEL TO AN ACCESSIBLE SPACE ABOVE OR BELOW. A MINIMUM OF ONE 3/4" CONDUIT SHALL BE INSTALLED FOR EVERY THREE SINGLE POLE SPARE CIRCUIT BREAKERS OR SPACES, OR FRACTION THEREOF, BUT NOT LESS THAN TWO CONDUITS. 28. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY UL OR OTHER RECOGNIZED TESTING FACILITY. 29. WIRE TERMINATION PROVISIONS FOR PANELBOARDS, CIRCUIT BREAKERS, SAFETY SWITCHES, AND ALL OTHER ELECTRICAL APPARATUS SHALL BE LISTED AS SUITABLE FOR 75 DEGREES C. DESIGN DEVELOPMENT PANELBOARD, ELECTRICAL DISTRIBUTION PANEL, OR LOAD CENTER SURFACE MOUNTED THIS IS A MASTER SYMBOLS LIST. ALL SYMBOLS, ABBREVIATIONS, ETC. MAY NOT NECESSARILY BE USED ON ALL DRAWINGS LIGHTING JACKSON, WYOMING POWER 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f ELECTRICAL GENERAL NOTES TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY ELECTRICAL SYMBOLS NOTE: NOT FOR CONSTRUCTION 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: 3123 ELECTRICAL LEGEND AND NOTES E-000 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants KEY NOTES 300HP CNG COMPRESSOR SKID. 2. EMERGENCY SHUT DOWN (ESD) BUTTON. 3. 5HP AIR COMPRESSOR AND DRYER. 4. 2HP DIESEL PUMP. 5. 1.5HP GASOLINE PUMP. 6. FUEL MANAGEMENT TERMINAL. 7. FUEL DISPENSING CONTROL PANEL. SS1 SW3 SW3 SS1 SS4 SS2 SW3 SW3 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY SS1 SW3 SW3 DIESEL GENERATOR SERVICE TRANSFORMER SS4 208V-1ø GUTTER HEAT TRACE CIRCUIT J 1 SW3 1 SW3 SS2 SS4 SS1 3 SW3 SW3 7 SW3 4 5 SW3 SS4 SA2 J SA2 6 DIESEL GENERATOR SS3 SA2 SA2 SA2 SW3 208V-1ø DOWNSPOUT HEAT TRACE CIRCUIT J SA2 SW3 SW3 2 SW3 SS2 SW3 SW3 6 2 ST4 ST4 ST4 ST4 ST4 ST4 ST4 ST4 SA1 J LOAD BANK SW3 208V-1ø DOWNSPOUT HEAT TRACE CIRCUIT SW3 DW SERVICE TRANSFORMER DESIGN DEVELOPMENT SW3 SW3 JACKSON, WYOMING SS1 1. (THIS SHEET) XXL1 IID1 SA1 SA1 SA1 SA1 SS1 IID1 XXW3 SS1 NOT FOR CONSTRUCTION 654 208V-1ø DOWNSPOUT HEAT TRACE CIRCUIT SA1 XXW3 XXW3 XXW3 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker ELECTRICAL SITE PLAN 4/1/2013 9:49:19 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: E-001 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) ELECTRICAL DEVICES TO BE INSTALLED WITHIN BUS STORAGE, DRIVE AISLE, REPAIR, STORAGE & WORK ROOM AREAS SHALL BE MOUNTED AT A MINIMUM HEIGHT OF 36" AFF. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com F.9 H.5 L J.5 M P N P.2 R Job #: 755.011 High Performance Building Consultants B2 FACP RHM-10 RHM-8B A8 WP GFI WP WP GFI WG WG UH-1 WG B3 SERVICE DOOR OPERATOR J BUS PARKING 1 GUH-1 A9 WP GFI WASH EQUIP/ COMPRESSOR 166 WP GFI RHM-6 3841 RECYCLING /PUMP CONTROL PANEL 3841 OZONE GENERATOR WP GFI 3841 MAIN CONTROL PANEL WP GFI A10 WP GFI B4 VEHICLE BYPASS 152 WP GFI L1 T-L1 BUS WASH 153 HDP1 2228 2161 UH-2 WG WG A11 M BUS PARKING 2 3841 WP GFI A12 ATS-LS WG ELEC EQUIP 168 EAST BUS PARKING 150 SERVICE DOOR OPERATOR J ESB J B5 SERVICE DOOR OPERATOR EUH-5 A13 ECB-2 T-LDP1 T-LDP2 ECB-1 WP GFI WP GFI SB1 BUS PARKING 3 WG DESIGN DEVELOPMENT RHM-5 JACKSON, WYOMING UH-3 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY WATER ENTRY 167 ELEC SWITCH GEAR 169 WG ATS-SB NOT FOR CONSTRUCTION A14 RHM-4 MSB EUH-6 LCP1 LTG1 A15 SERVICE DOOR MASTER CONTROL PANEL SERVICE DOOR OPERATOR B6 F SERVICE DOOR OPERATOR J SERVICE DOOR OPERATOR J J F F E A16 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 4/1/2013 9:49:19 AM CHECKED BY: Checker F.9 DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 H.5 J J.5 K BUS PARKING LEVEL 1 - AREA A - POWER PLAN SCALE: 1/8" = 1'-0" K.9 M N.1 P P.2 R B A 3123 LEVEL 1 - POWER PLAN - AREA A E-111 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) ELECTRICAL DEVICES TO BE INSTALLED WITHIN BUS STORAGE, DRIVE AISLE, REPAIR, STORAGE & WORK ROOM AREAS SHALL BE MOUNTED AT A MINIMUM HEIGHT OF 36" AFF. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 C D.5 E.5 F.9 WG High Performance Building Consultants WG B3 BUS PARKING 4 WP GFI RHM-3 WP GFI B4 BUS PARKING 5 B5 WP GFI WP GFI DESIGN DEVELOPMENT RHM-2 JACKSON, WYOMING WG TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY WG BUS PARKING 6 WG WG NOT FOR CONSTRUCTION RHM-1 SERVICE DOOR OPERATOR SERVICE DOOR OPERATOR J B6 SERVICE DOOR OPERATOR J F E J D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 4/1/2013 9:49:20 AM CHECKED BY: Checker C DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 C.1 D.5 E.5 BUS PARKING LEVEL 1 - AREA B - POWER PLAN SCALE: 1/8" = 1'-0" F.9 B A 3123 LEVEL 1 - POWER PLAN - AREA B E-112 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) ELECTRICAL DEVICES TO BE INSTALLED WITHIN BUS STORAGE, DRIVE AISLE, REPAIR, STORAGE & WORK ROOM AREAS SHALL BE MOUNTED AT A MINIMUM HEIGHT OF 36" AFF. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H H.5 J J.5 K L M P.1 S R N.1 WP GFI WG RHM-9A J B1 WP GFI B1 DRUG TEST 154 SERVICE DOOR OPERATOR RHM-9B DIRECTOR 155 FARE ROOM 164 VAV-14 GFI WG MARKETING 157 A1 GD A2 A2 GFI GFI VAV-02 DW PIT OFFICE 159 HD ELEVATOR E1 VAV-03 A3 VEHICLE DRIVE AISLE 136 WP GFI A3 VAV-04 BBH-1 A5 A5 DESIGN DEVELOPMENT BREAK/ COPY 156 A1 JACKSON, WYOMING WP GFI TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY VAV-01 LOBBY 160 BBH-1 A7 WP GFI A7 COMM 165 NEMA 6-20R VESTIBULE 161 F WG VESTIBULE 162 LOST & FOUND 163 H H.5 J J.5 K L NOT FOR CONSTRUCTION M F P.1 R S D E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker N.1 1 4/1/2013 9:49:21 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: DRIVE AISLE LEVEL 1 - AREA C - POWER PLAN B A 3123 LEVEL 1 - POWER PLAN - AREA C SCALE: 1/8" = 1'-0" E-113 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) ELECTRICAL DEVICES TO BE INSTALLED WITHIN BUS STORAGE, DRIVE AISLE, REPAIR, STORAGE & WORK ROOM AREAS SHALL BE MOUNTED AT A MINIMUM HEIGHT OF 36" AFF. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A B C D WP GFI B1 E D.5 E.5 F G WP GFI WG H WG TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY A1 A2 A3 VEHICLE DRIVE AISLE 136 A5 DESIGN DEVELOPMENT WP GFI JACKSON, WYOMING F WG WP GFI A7 NOT FOR CONSTRUCTION F 2341 WG RHM-7 SERVICE DOOR OPERATOR WP GFI J B2 RHM-8A WP GFI F A B C D D.5 E E.5 F F.9 E H D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 9:49:21 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: DRIVE AISLE LEVEL 1 - AREA D - POWER PLAN SCALE: 1/8" = 1'-0" B A 3123 LEVEL 1 - POWER PLAN - AREA D E-114 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) ELECTRICAL DEVICES TO BE INSTALLED WITHIN BUS STORAGE, DRIVE AISLE, REPAIR, STORAGE & WORK ROOM AREAS SHALL BE MOUNTED AT A MINIMUM HEIGHT OF 36" AFF. KEY NOTES (THIS SHEET) 1. NEMA 6-20R RETRACTABLE CORD REEL MOUNTED TO BOTTOM OF STRUCTURE. NOT SHOWN THIS SHEET. 2. NEMA 5-20R GFCI RETRATCABLE CORD REEL MOUNTED TO BOTTOM OF STRUCTURE. NOT SHOWN THIS SHEET. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants J H.5 F L.1 F J M1 K J.5 P M P.1 P.2 Q R R2 J H WP GFI NEMA 6-20R WG SERVICE DOOR OPERATOR WP GFI SERVICE DOOR OPERATOR COMM 001 WG TOOL CRIB 110 LUBE/ COMPRESSOR 112 R3 WP GFI F M2 7240 WP GFI WP GFI GFI PARTS STORAGE 111 TOOLBOX STORAGE 113 2231 WP GFI GFI 2165 R4 WG WP GFI 7540 7541 WP GFI M3 BATTERY STORAGE 114 WP GFI EF-3 GFI 2045 2045 GFI GFI WP GFI SERVICE DOOR OPERATOR WP GFI J WG MAINTENANCE SUPERVISOR 115 WP GFI 49051 PARTS ACCESS 116 TIRE SHOP 117 WP GFI R5 PARTS LIFT WP GFI J GFI R6 GUH-2 M5 5775 CONTROLS GFI WP/WG 2340 R7 HEAVY REPAIR 2 HEAVY REPAIR 1 1 1 2 5775 WP GFI 29351 NEMA 6-20R 2 29161 DESIGN DEVELOPMENT WG JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY F M4 PORTABLE EQUIP STORAGE 118 24501 T-LDP3 NEMA 6-30R LDP3 ELECTRICAL 006 5691 L7 R8 5691 CONTROLS & ADAPTER RACK PORTABLE EQUIP STORAGE 131 5861 (SET OF 6) SERVICE DOOR OPERATOR WP GFI M6 WP GFI SERVICE DOOR OPERATOR WG J NOT FOR CONSTRUCTION CHASSIS WASH 133 WP GFI WASHRHM-16B EQUIP. 132 WP HD WP ELEV-2 WP/WG HD PIT WP GFI J F B1 E B1 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: H.3 J K L L.1 M N.1 P P.2 R S CHECKED BY: Checker B 4/1/2013 9:49:24 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt H 1 MAINTENANCE LEVEL 1 - AREA E - POWER PLAN SCALE: 1/8" = 1'-0" A 3123 LEVEL 1 - POWER PLAN - AREA E E-115 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) ELECTRICAL DEVICES TO BE INSTALLED WITHIN BUS STORAGE, DRIVE AISLE, REPAIR, STORAGE & WORK ROOM AREAS SHALL BE MOUNTED AT A MINIMUM HEIGHT OF 36" AFF. KEY NOTES (THIS SHEET) 1. NEMA 6-20R RETRACTABLE CORD REEL MOUNTED TO BOTTOM OF STRUCTURE. NOT SHOWN THIS SHEET. 2. NEMA 5-20R GFCI RETRATCABLE CORD REEL MOUNTED TO BOTTOM OF STRUCTURE. NOT SHOWN THIS SHEET. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A B D E D.5 F E.5 G H WP GFI M1 J J WP GFI SERVICE DOOR OPERATOR F SERVICE DOOR OPERATOR F WG NEMA 6-30R BREAK ROOM 102 WP GFI NEMA 6-20R 29141 GFI 29151 GFI GD 29401 REBUILD SHOP 101 GFI MEN 103 NEMA 6-20R 2 22051 J M2 26901 J 1 SERVICE DOOR OPERATOR 20761 SERVICE DOOR OPERATOR SERVICE DOOR OPERATOR J WP GFI J NEMA 6-30R WP GFI GFI WOMEN 104 NEMA 6-30R NEMA 6-20R 5716 23441 57141 GFI J LIGHT REPAIR 3 WG WP GFI LIGHT REPAIR 2 LIGHT REPAIR 1 WG WP GFI 1 2 1 2 1 2 M3 21911 26981 NEMA 6-30R COMMON WORK AREA 105 WG MANUALS & COPY 106 WG NEMA 6-20R 20751 23601 7541 WP GFI WP GFI TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY FORKLIFT AISLE 119 7540 WG M5 WP GFI 35401 HEAVY REPAIR BAYS 120 WP GFI HEAVY REPAIR 8 HEAVY REPAIR 7 HEAVY REPAIR 6 HEAVY REPAIR 5 1 1 1 1 2 2 2 HEAVY REPAIR 3 2 1 2 1 DESIGN DEVELOPMENT 25501 M4 JACKSON, WYOMING 22201 3784 2 5775 5691 5691 CONTROLS & ADAPTER RACK SERVICE DOOR MASTER CONTROL PANEL 5842 (SET OF 4) J J 58421 (SET OF 4) 5775 CONTROLS SERVICE DOOR OPERATOR WG M6 58401 (SET OF 4) 58401 (SET OF 4) SERVICE DOOR OPERATOR NOT FOR CONSTRUCTION SERVICE DOOR OPERATOR SERVICE DOOR OPERATOR WP GFI WG WP GFI J SERVICE DOOR OPERATOR SERVICE DOOR OPERATOR WG J J J B1 F A B C D E F G E H D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B 1 4/1/2013 9:49:26 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: A 3123 LEVEL 1 - POWER PLAN - AREA F MAINTENANCE LEVEL 1 - AREA F - POWER PLAN SCALE: 1/8" = 1'-0" E-116 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants GENERAL NOTES GAS DRYER CONTROL PANEL 300HP COMPRESSOR CONTROL PNL WP GFI 20HP COOLER FAN CONTROL PNL WP GFI F L8 HDP4 T-L8 ELECTRICAL/STORAGE SB2 3 ATS-SB2 WP GFI MSB2 HD COMPRESSORS 1 DESIGN DEVELOPMENT 1 JACKSON, WYOMING WIRING METHODS UTILIZED WITHIN COMPRESSOR ROOM 1 OF THE CNG SHALL BE SUITABLE FOR CLASS 1, DIVISION 1 HAZARDOUS LOCATIONS. ALL EQUIPMENT INSTALLED THIS SPACE SHALL BE EXPLOSIONPROOF. TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 1. (THIS SHEET) HD 2158 2228 COMPRESSOR ROOM 4 WP GFI F OFFICE 2 NOT FOR CONSTRUCTION Z 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker LEVEL 1 - POWER PLAN - CNG BUILDING 4/1/2013 9:49:27 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: E-117 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com F.9 H.5 J.5 L P M P.2 R Job #: 755.011 High Performance Building Consultants N.1 B2 A8 B3 A9 A10 B4 B5 A13 GFI NOT FOR CONSTRUCTION A14 A15 F F B6 E A16 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B 4/1/2013 9:49:28 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: F.9 1 H.5 J.5 BUS PARKING LEVEL 2 - AREA A - POWER PLAN SCALE: 1/8" = 1'-0" L L.1 L.9 M P.2 N.1 DESIGN DEVELOPMENT A12 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY A11 A 3123 LEVEL 2 - POWER PLAN - AREA A R E-121 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants KEY NOTES (THIS SHEET) 1. EMERGENCY POWER OFF PUSHBUTTON: PUSH IN "OFF", PULL OUT "ON". PUSHBUTTON SHALL BE 1-1/2" DIAMETER, RED, MUSHROOM TYPE WITH HINGED POLYCARBONATE COVER. LABEL "EMERGENCY POWER OFF". PROVIDE 10-POLE CONTACTOR WITH 120V COIL, NOT SHOWN. ACTUATION OF PUSHBUTTON SHALL DEENERGIZE 120V CIRCUITS TO: B-1,B-2,B-3,WH-1, & WH-2 AND SHALL CONTROL ON/OFF STATE OF GAS SHUT-OFF VALVE SERVING BOILER ROOM. PROVIDE ALL ASSOCIATED 120V & CONTROL WIRING. COORDINATE INSTALLATION WITH DIVISION 22 & 23 CONTRACTORS. H H.5 J J.5 K L M P.1 R S N.1 B1 HDP2 LDP1 L3 L2 A LTG2 HLS B1 GFI LS T-LS GFI A1 A2 A2 ERV-1 HD A3 A3 WG 1 F A5 A5 SWH-2 DESIGN DEVELOPMENT A1 JACKSON, WYOMING GFI TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY GFI HWP-1 B-1 B-2 NOT FOR CONSTRUCTION HWP-2 AHU-1 A7 A7 B-3 HWP-3 1 F H H.3 J K L M P.2 R S D E C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 9:49:29 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: DRIVE AISLE LEVEL 2 - AREA C - POWER PLAN N.1 B A 3123 LEVEL 2 - POWER PLAN - AREA C SCALE: 1/8" = 1'-0" E-123 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants P.1 P.2 Q N R P P.2 Q R F F P R2 R2 M1 CO CO WP ELECTRIC RANGE NEMA 6-50R R3 ELECTRIC RANGE NEMA 6-50R WP GFI R3 GFI GD GD M2 CO CO GFI GFI R3 R7 GFI GFI R4 R4 GFI GFI R2 R6 GFI GFI M3 CO CO GFI GFI GD HOUSING UNIT 6 R5 M4 ELECTRIC RANGE NEMA 6-50R CO CO R6 R6 M5 WASHER HDP3 HD DRYER NEMA 6-50R LDP2 CO L6 ELECTRIC RANGE NEMA 6-50R L5 CO WP L4 R7 R7 GD GFI WP HEAVY REPAIR 2 GFI HEAVY REPAIR 1 GFI ERV-2 DESIGN DEVELOPMENT ELECTRIC RANGE NEMA 6-50R JACKSON, WYOMING R5 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY GFI CO GFI CO R1 ERV-2 NOT FOR CONSTRUCTION GFI R8 F F R8 ERV-2 HD WP HD WP WP WP HD M6 F B1 E B1 H H.3 J K L M N P P.2 R S D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: P P.2 R S CHECKED BY: Checker B 4/1/2013 9:49:31 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt N 1 MAINTENANCE LEVEL 2 - AREA E - POWER PLAN SCALE: 1/8" = 1'-0" A 3123 LEVEL 2 - POWER PLAN - AREA E E-125 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H H.5 J J.5 K L M P N P.2 Q R S N.1 B1 B1 WP GFI A2 A2 A3 A3 A5 A5 A7 NOT FOR CONSTRUCTION A7 F H H.3 J K L M N P P.2 Q R CHECKED BY: Checker 4/1/2013 9:49:32 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt 1 SCALE: 1/8" = 1'-0" E S D DRIVE AISLE ROOF - AREA C - ELECTRICAL PLAN DESIGN DEVELOPMENT A1 JACKSON, WYOMING A1 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY EF-1 C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: N.1 B A 3123 ROOF - POWER PLAN - AREA C E-133 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H.5 J J.5 K L P M P.2 R R2 M1 R3 M2 R4 M3 R5 M5 ERV-3 WP GFI R7 DESIGN DEVELOPMENT R6 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY M4 NOT FOR CONSTRUCTION R8 M6 F B1 E B1 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: H.3 J K L M N.1 P P.2 R S CHECKED BY: Checker B 4/1/2013 9:49:35 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt H 1 MAINTENANCE ROOF - AREA E - ELECTRICAL PLAN SCALE: 1/8" = 1'-0" A 3123 ROOF - POWER PLAN - AREA E E-135 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants B D D.5 E.5 F H F.9 A M1 EF-2 WP GFI M2 M3 DESIGN DEVELOPMENT M5 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY M4 NOT FOR CONSTRUCTION M6 B1 F B C D E F G H D CHECKED BY: Checker C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: B 4/1/2013 9:49:37 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt A E A 3123 ROOF - POWER PLAN - AREA F E-136 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 DESIGN DEVELOPMENT 1 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY High Performance Building Consultants NOT FOR CONSTRUCTION EF-16 WP GFI Z 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker ROOF - CNG BUILDING 4/1/2013 9:49:38 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: E-137 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) LIGHTING CONTROL STRATEGIES SHALL INCLUDE AUTOMATIC SHUT-OFF RESPONSIVE TO VACANCY DETECTION AND AUTOMAITC DIMMING RESPONSIVE TO DAYLIGHT LEVELS. LIGHTING CONTROL DEVICES TO INCLUDE PHOTO SENSORS, OCCUPANCY SENSORS & VACANCY SENSORS WILL PROVIDE INPUT TO A NETWORKED LIGHTING CONTROL PANEL. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com F.9 H.5 J.5 K.9 N L.9 P.2 R Job #: 755.011 High Performance Building Consultants N.1 B2 OS AA2 A8 AA5 DD1 DD1 DD1 AA2 S1 S1 F2 B3 BUS PARKING 1 XXC1 F2 S1 F2 F2 A9 XXC1 F2 F2 F2 WASH EQUIP/ COMPRESSOR 166 XXC1 F2 F2 S1 F2 A10 S1 S1 S1 B4 XXC1 F2 F2 VEHICLE BYPASS 152 F2 F2 XXC1 BUS WASH 153 F2 S1 F2 A11 F2 XXC1 F1 WATER ENTRY 167 XXC1 F2 S1 F2 A12 F1 ELEC EQUIP 168 S1 F2 S1 EAST BUS PARKING 150 XXC1 F2 F1 S1 S1 B5 XXC1 F1 A13 XXC1 F1 BUS PARKING 3 ELEC SWITCH GEAR 169 DESIGN DEVELOPMENT F2 JACKSON, WYOMING F2 S1 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY BUS PARKING 2 XXC1 F1 NOT FOR CONSTRUCTION A14 F1 A15 F S1 S1 E S1 B6 A16 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B F.9 4/1/2013 9:49:40 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: H.5 1 J.5 BUS PARKING LEVEL 1 - AREA A - LIGHTING PLAN SCALE: 1/8" = 1'-0" K.9 L.9 N N.1 P.2 A 3123 LEVEL 1 - LIGHTING PLAN - AREA A R E-141 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) LIGHTING CONTROL STRATEGIES SHALL INCLUDE AUTOMATIC SHUT-OFF RESPONSIVE TO VACANCY DETECTION AND AUTOMAITC DIMMING RESPONSIVE TO DAYLIGHT LEVELS. LIGHTING CONTROL DEVICES TO INCLUDE PHOTO SENSORS, OCCUPANCY SENSORS & VACANCY SENSORS WILL PROVIDE INPUT TO A NETWORKED LIGHTING CONTROL PANEL. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 C.1 D.5 E.5 F.9 High Performance Building Consultants B3 S1 S1 S1 S1 S1 S1 DESIGN DEVELOPMENT B5 JACKSON, WYOMING TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY B4 NOT FOR CONSTRUCTION F S1 S1 E S1 B6 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 4/1/2013 9:49:42 AM CHECKED BY: Checker C.1 DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 D.5 E.5 BUS PARKING LEVEL 1 - AREA B - LIGHTING PLAN SCALE: 1/8" = 1'-0" F.9 B A 3123 LEVEL 1 - LIGHTING PLAN - AREA B E-142 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants GENERAL NOTES 1. LIGHTING CONTROL STRATEGIES SHALL INCLUDE AUTOMATIC SHUT-OFF RESPONSIVE TO VACANCY DETECTION AND AUTOMAITC DIMMING RESPONSIVE TO DAYLIGHT LEVELS. LIGHTING CONTROL DEVICES TO INCLUDE PHOTO SENSORS, OCCUPANCY SENSORS & VACANCY SENSORS WILL PROVIDE INPUT TO A NETWORKED LIGHTING CONTROL PANEL. N B1 N.1 P.1 DIRECTOR 155 CC1 DRUG TEST 154 F1 S R B1 OS F1 CC1 DD1 AA1 S1 OS AA1 AA1 D AA2 A2 AA2 MARKETING 157 D BREAK/ COPY OS 156 A1 AA1 A2 AA2 D S1 AA1 OFFICE 159 OS AA2E WW1 A1 AA1 AA1 A3 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY OS AA2 A3 WW1 VEHICLE DRIVE AISLE 136 PP1 PP1 PP1 A5 A5 LOBBY 160 S1 PP1 (TYP.) A7 DESIGN DEVELOPMENT J.5 JACKSON, WYOMING H.5 (THIS SHEET) NOT FOR CONSTRUCTION A7 SS1 VESTIBULE 161 S1 DD1 AA5 AA2E VESTIBULE 162 LOST & FOUND 163 DD1 F H H.3 J K L L.1 L.9 M N N.1 P.1 R E S D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 9:49:44 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: DRIVE AISLE LEVEL 1 - AREA C - LIGHTING PLAN B A 3123 LEVEL 1 - LIGHTING PLAN - AREA C SCALE: 1/8" = 1'-0" E-143 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants GENERAL NOTES 1. A B C D E D.5 E.5 (THIS SHEET) LIGHTING CONTROL STRATEGIES SHALL INCLUDE AUTOMATIC SHUT-OFF RESPONSIVE TO VACANCY DETECTION AND AUTOMAITC DIMMING RESPONSIVE TO DAYLIGHT LEVELS. LIGHTING CONTROL DEVICES TO INCLUDE PHOTO SENSORS, OCCUPANCY SENSORS & VACANCY SENSORS WILL PROVIDE INPUT TO A NETWORKED LIGHTING CONTROL PANEL. F F.9 G H S1 S1 S1 S1 A2 A3 VEHICLE DRIVE AISLE 136 A5 S1 S1 S1 A7 DESIGN DEVELOPMENT S1 JACKSON, WYOMING S1 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY B1 NOT FOR CONSTRUCTION S1 S1 S1 B2 F A B C C.1 D D.5 E E.5 F F.9 G E H D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 9:49:46 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: DRIVE AISLE LEVEL 1 - AREA D - LIGHTING PLAN SCALE: 1/8" = 1'-0" B A 3123 LEVEL 1 - LIGHTING PLAN - AREA D E-144 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES 1. (THIS SHEET) m GR UP e d e s i g n LIGHTING CONTROL STRATEGIES SHALL INCLUDE AUTOMATIC SHUT-OFF RESPONSIVE TO VACANCY DETECTION AND AUTOMAITC DIMMING RESPONSIVE TO DAYLIGHT LEVELS. LIGHTING CONTROL DEVICES TO INCLUDE PHOTO SENSORS, OCCUPANCY SENSORS & VACANCY SENSORS WILL PROVIDE INPUT TO A NETWORKED LIGHTING CONTROL PANEL. 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants H H.3 H.5 J.5 K L L.1 P M P.1 P.2 Q XXW2 R2 M1 S1 F1 TOOL CRIB 110 S1 S1 F1 S1 LUBE/ COMPRESSOR 112 R3 F1 S1 PARTS STORAGE 111 M2 F1 TOOLBOX STORAGE 113 S1 S1 S1 F1 R4 S2 F2 F2 BATTERY STORAGE 114 F1 M3 C1 PORTABLE EQUIP STORAGE 118 F1 TIRE SHOP 117 F1 M4 S1 S1 F2 F2 F2 F2 F2 F2 F2 F2 R6 M5 HEAVY REPAIR 2 HEAVY REPAIR 1 R7 DESIGN DEVELOPMENT C1 R5 JACKSON, WYOMING PARTS ACCESS 116 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY MAINTENANCE SUPERVISOR 115 S1 NOT FOR CONSTRUCTION R8 F2 F2 XXW2 PORTABLE EQUIP STORAGE 131 WW3 F1 F2 F1 WW3 F2 M6 F B1 D H.3 J J.5 K L L.1 M N P P.2 R CHECKED BY: Checker 1 MAINTENANCE LEVEL 1 - AREA E - LIGHTING PLAN SCALE: 1/8" = 1'-0" C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: S B N.1 4/1/2013 9:49:48 AM D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt H DRAWN BY: Author E B1 A 3123 LEVEL 1 - LIGHTING PLAN - AREA E E-145 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES 1. (THIS SHEET) LIGHTING CONTROL STRATEGIES SHALL INCLUDE AUTOMATIC SHUT-OFF RESPONSIVE TO VACANCY DETECTION AND AUTOMAITC DIMMING RESPONSIVE TO DAYLIGHT LEVELS. LIGHTING CONTROL DEVICES TO INCLUDE PHOTO SENSORS, OCCUPANCY SENSORS & VACANCY SENSORS WILL PROVIDE INPUT TO A NETWORKED LIGHTING CONTROL PANEL. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants A B C D D.5 E.5 F H F.9 M1 S1 S1 S1 C1 C1 C1 C1 S1 S1 A2 S1 A2 A2 A2 M2 A2 S1 S1 S1 A2 A2 A2 S2 S1 S2 A2 A2 S1 S2 S1 M3 S2 S2 C1 C1 C1 C1 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 M5 DESIGN DEVELOPMENT S2 JACKSON, WYOMING S2 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY M4 NOT FOR CONSTRUCTION M6 B1 F A B C D D.5 E E.5 F F.9 G E H D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 9:49:50 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: MAINTENANCE LEVEL 1 - AREA F - LIGHTING PLAN B A 3123 LEVEL 1 - LIGHTING PLAN - AREA F SCALE: 1/8" = 1'-0" E-146 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 WIRING METHODS UTILIZED WITHIN COMPRESSOR ROOM 1 OF THE CNG SHALL BE SUITABLE FOR CLASS 1, DIVISION 1 HAZARDOUS LOCATIONS. ALL EQUIPMENT INSTALLED THIS SPACE SHALL BE EXPLOSIONPROOF. 1 3 DESIGN DEVELOPMENT 1. (THIS SHEET) JACKSON, WYOMING GENERAL NOTES TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY High Performance Building Consultants 3 3 ELECTRICAL/STORAGE 3 NOT FOR CONSTRUCTION COMPRESSORS 1 3 OS OFFICE 2 Z 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker 1 4/1/2013 9:49:51 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: CNG LEVEL 1 - LIGHTING PLAN SCALE: 1/8" = 1'-0" 3123 LEVEL 1 - LIGHTING PLAN - CNG BUILDING E-147 1. 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES (THIS SHEET) LIGHTING CONTROL STRATEGIES SHALL INCLUDE AUTOMATIC SHUT-OFF RESPONSIVE TO VACANCY DETECTION AND AUTOMAITC DIMMING RESPONSIVE TO DAYLIGHT LEVELS. LIGHTING CONTROL DEVICES TO INCLUDE PHOTO SENSORS, OCCUPANCY SENSORS & VACANCY SENSORS WILL PROVIDE INPUT TO A NETWORKED LIGHTING CONTROL PANEL. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com F.9 H.5 L J.5 N P.2 Job #: 755.011 R High Performance Building Consultants N.1 CC1 B2 A8 DD4 AA1 PP2 RR1 DD4 DD4 AA1 CC2 AA1 RR1 CC2 RR1 CC2 AA1 PP2 OS AA1 AA1 A9 RR1 AA1 AA1 PP2 DD4 DD1 PP2 DD1 DD4 CC1D DD4 AA3 OS CC1D DD1 DD1 AA3 OS CC1D A10 DD1 DD1 AA3 PP2 B4 DD1 DD1 DD1 DD1 CC1D CC1D AA3 PP2 AA3 CC1D OS DD1 DD1 CC2 CC2 AA1 PP2 A11 CC2 AA1 AA1 AA1 AA1 PP2 DD2 A12 PP2 B5 PP2 PP2 PP2 PP2 A13 RR3 RR2 PP2 PP2 PP2 DESIGN DEVELOPMENT AA1 JACKSON, WYOMING DD2 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY OS PP2 NOT FOR CONSTRUCTION A14 A15 F B6 E A16 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. CHECKED BY: Checker B H.3 F.9 4/1/2013 9:49:52 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: 1 J K BUS PARKING LEVEL 2 - AREA A - LIGHTING PLAN SCALE: 1/8" = 1'-0" L L.1 M N P.2 N.1 A 3123 LEVEL 2 - LIGHTING PLAN - AREA A R E-151 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants GENERAL NOTES 1. H J H.5 J.5 K L (THIS SHEET) LIGHTING CONTROL STRATEGIES SHALL INCLUDE AUTOMATIC SHUT-OFF RESPONSIVE TO VACANCY DETECTION AND AUTOMAITC DIMMING RESPONSIVE TO DAYLIGHT LEVELS. LIGHTING CONTROL DEVICES TO INCLUDE PHOTO SENSORS, OCCUPANCY SENSORS & VACANCY SENSORS WILL PROVIDE INPUT TO A NETWORKED LIGHTING CONTROL PANEL. P M P.2 R N.1 B1 B1 CC1 CC1 DD3 CC1 CC1 CC1 CC1 CC1 OS DD1E SS1 A2 DD1E DD1E A1 DD1 CC1 OS BB1 DD2 A1 A2 BB1 BB1 OS S1 S1 S1 A3 DD1E WW1 CC1 BB1 BB1 A3 WW1 AA4 CC1 PP1 PP1 PP1PP1 PP1PP1 CC1 AA4 A5 S1 S1 S1 CC1 AA4 AA4 CC1 AA4 A5 PP1PP1PP1PP1PP1 PP1 PP1 PP1 PP1 PP1 CC1 DESIGN DEVELOPMENT CC1 CC1 JACKSON, WYOMING S1 DD1 CC1 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY S1 S1 CC1 AA4 PP1 PP1 PP1 PP1 PP1 PP1 PP1 PP1 PP1 PP1 CC1 AA4 PP1 PP1 PP1 PP1 PP1 PP1 PP1 PP1 PP1 PP1 CC1 AA4 NOT FOR CONSTRUCTION K.9 A7 A7 CC1 S1 S1 S1 CC1 CC1 CC1 F H H.3 J K L L.1 L.9 P M E S D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: CHECKED BY: Checker 1 4/1/2013 9:49:53 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt N.1 DRIVE AISLE LEVEL 2 - AREA C - LIGHTING PLAN B A 3123 LEVEL 2 - LIGHTING PLAN - AREA C SCALE: 1/8" = 1'-0" E-153 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL NOTES 1. (THIS SHEET) LIGHTING CONTROL STRATEGIES SHALL INCLUDE AUTOMATIC SHUT-OFF RESPONSIVE TO VACANCY DETECTION AND AUTOMAITC DIMMING RESPONSIVE TO DAYLIGHT LEVELS. LIGHTING CONTROL DEVICES TO INCLUDE PHOTO SENSORS, OCCUPANCY SENSORS & VACANCY SENSORS WILL PROVIDE INPUT TO A NETWORKED LIGHTING CONTROL PANEL. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants P P.2 R J H.5 J.5 K L.1 P M P.1 P.2 Q R N.1 XXW2 M1 WW5 WW5 WW5 WW5 DD3 DD4 DD4 BB2 R3 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 WW5 WW5 WW6 TT1 WW6 DD3 DD4 DD4 BB2 WW6 DD3 DD3 M2 DD4 DD3 WW4 WW4 WW5 DD4 DD5 DD4 DD3 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 R3 WW6 DD3 WW5 DD5 DD4 DD4 DD4 WW5 R4 WW2 DD4 DD5 R4 WW5 DD4 DD5 WW5 DD3 WW4 DD4 DD3 WW5 WW2 DD4 DD4 DD4 WW4 DD4 WW2 WW2 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 WW6 M3 DD4 DD3 WW5 DD4 DD3 WW5 DD3 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 WW6 DD3 TT1 TT1 TT1 WW5 WW5 WW5 WW5 S1 R6 S2 WW5 TT1 TT1 TT1 WW5 TT1 BB2 M4 DD3 R5 WW6 DD4 WW5 WW5 WW5 WW5 R6 S2 WW5 WW5 M5 WW5 WW5 TT1 WW6 WW6 DD3 TT1 TT1 TT1 TT1 TT1 TT1 DD4 DD4 BB2 S1 R7 WW6 DD5 WW5 WW4 WW5 WW5 HEAVY REPAIR 2 WW5 HEAVY REPAIR 1 DD4 WW4 S1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 TT1 DD3 DD3 WW5 DD5 TT1 DD4 DD4 DD4 WW2 R8 S2 XXW2 WW3 R7 WW6 DD3 WW4 DD5 TT1 S2 XXW2 WW3 WW3 DESIGN DEVELOPMENT DD4 DD3 TT1 DD4 WW6 JACKSON, WYOMING DD4 TT1 TT1 DD3 DD4 R5 R2 WW5 WW5 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY R2 WW5 NOT FOR CONSTRUCTION R8 XXW2 WW3 M6 F B1 B1 E B1 D C 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: P.2 R H H.3 J K L M N.1 P P.2 R S CHECKED BY: Checker B 4/1/2013 9:49:58 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt N.1 1 MAINTENANCE LEVEL 2 - AREA E - LIGHTING PLAN SCALE: 1/8" = 1'-0" A 3123 LEVEL 2 - LIGHTING PLAN - AREA E E-155 FEEDER KEY 1. COPPER CONDUCTORS FIRE ALARM SYSTEM SHALL BE BY DELEGATED-DESIGN SUBMITTAL. REFERENCE SPECIFICATION 283111 FOR GENERAL SUBMITTAL REQUIREMENTS. THE QUALIFIED SYSTEM DESIGNER SHALL DESIGN A SYSTEM COMPLIANT WITH THE REQUIREMENTS OF IFC, NFPA, STATE OF WYOMING (AHJ), CITY OF JACKSON (AHJ), TETON COUNTY (AHJ) AND JACKSON FIRE DEPARTMENT (AHJ). 3. CONTRACTOR SHALL PROVIDE AN ADDRESSABLE ANALOG FIRE ALARM SYSTEM TO INCLUDE, AT A MINIMUM, THE FOLLOWING SYSTEM COMPONENTS AND FUNCTIONS: A. B. C. D. E. F. G. H. 2. PUBLIC OPERATING MODE WITH AUDIBLE AND VISIBLE NOTIFICATION VOICE/ALARM COMMUNICATIONS MANUAL FIRE ALARM SELECTIVE & SUPPLEMENTARY COVERAGE OF AUTOMATIC FIRE AND SMOKE DETECTION MONITORING OF ABNORMAL CONDITIONS ACTIVATION OF FIRE SUPPRESSION SYSTEMS ACTIVATION OF FIRE SAFETY FUNCTIONS TRANSMISSION OF ALARM SIGNALS TO OFF-SITE SUPERVISING STATION REMARK CONDUCTORS 5 ] ALL FIRE ALARM SYSTEM WIRING AND CABLING SHALL BE INSTALLED IN METAL CONDUIT REGARDLESS OF CODE EXCEPTIONS. 4. REFERENCE DIVISION 21 SPECIFICATIONS, DIVISION 23 SPECIFICATIONS, FIRE SUPPRESSION DRAWINGS AND MECHANICAL DRAWINGS FOR REQUIRED SEQUENCE OF OPERATIONS. 5. 120V POWER CIRCUITS FOR FIRE ALARM REMOTE POWER SUPPLIES ARE NOT SHOWN THIS FIRE ALARM RISER DIAGRAM OR ON THE DRAWINGS. QUANTITY AND LOCATIONS OF REMOTE POWER SUPPLIES SHALL BE DETERMINED BY THE QUALIFIED FIRE ALARM SYSTEM DESIGNER. 120V CIRCUITS SHALL BE PROVIDED AS REQUIRED BY FIRE ALARM SYSTEM DESIGN DOCUMENTS. COSTS ASSOCIATED WITH THESE CIRCUITS SHALL BE CARRIED IN THE CONTRACTOR'S BASE BID. [ "C 3-1/2 REMARK CONDUCTORS 50A3 G 3/4 3# 6 , 1# 10 G NA 70A3 G 1 3# 4 , 1# 8 G NA 250A3 G 2 3 # 250 , 1 # 4 G 2-1/2 3 # 350 , 1 # 2 G 100A4 G 1-1/2 4# 1 , 1# 8 G 1-1/2 4# 1 , 1# 6 G 150A4 G 1-1/2 4# 1/0 , 1 # 6 G 2 4# 3/0 , 1 # 4 G 175A4 G 2 4# 2/0 , 1 # 6 G 2-1/2 4# 4/0 , 1 # 4 G 225A4 G 2-1/2 4# 4/0 , 1 # 4 G 2-1/2 4 # 300 , 1 # 2 G [ 400A4 G 2 [ 2 4# 3/0 , 1 # 3 G ] 2 [ 2-1/2 4 # 250 , 1 # 1 G ] 800A4 G 3 [ 3 4 # 300 , 1 # 1/0 G ] 4 [ 2-1/2 4 # 250 , 1 # 3/0 G ] 5 [ 3-1/2 4 # 500 , 1 # 350 G ] SCHEDULE 80 5 [ 4 4 # 600 , 1 # 350 G ] SCHEDULE 80 5 4 # 400 , 1 # 3 [ 4/0 G ] CONTRACTOR SHALL COORDINATE INSTALLATION OF SERVICE TRANSFORMER WITH LOWER VALLEY ENERGY (LVE). CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIALS AS REQUIRED BY LVE. 2. ALL MOTOR CIRCUIT CONDUCTORS, GROUNDING ELECTRODE CONDUCTORS AND BRANCH CIRCUIT WIRING SHALL BE THHN/THWN INSULATED COPPER CONDUCTORS. 3. FEEDER TAGS THIS ONE-LINE HAVE SUBSCRIPTS DENOTING EITHER COPPER (CU) OR ALUMINUM (AL). 4. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR SIZED PER NFPA 70. A MAXIMUM OF THREE BRANCH CIRCUITS SHALL BE PERMITTED TO SHARE THE SAME HOMERUN. MULITWIRE BRANCH CIRCUITS SHALL NOT BE PERMITTED. 5. PROVIDE 4" THICK CONCRETE HOUSEKEEPING PADS FOR ALL TRANSFORMERS AND FREE STANDING ELECTRICAL ENCLOSURES. EXTEND HOUSEKEEPING PADS 6" BEYOND THE FOOT PRINT OF THE EQUIPMENT. 6. ALL WIRING SHALL BE IN CONDUIT. CONDUIT EXPOSED TO WEATHER SHALL BE HOT DIPPED, RIGID GALVANIZED STEEL. CONDUIT INSTALLED BELOW GRADE SHALL BE SCHEDULE 80 PVC. STUB-UPS FROM BELOW GRADE SHALL BE ACCOMPLISHED UTILIZING HOT DIPPED, RIGID GALVANIZED STEEL CONDUIT ELBOWS WRAPPED IN PVC TAPE. PVC CONDUIT IS NOT PERMITTED ABOVE GRADE. 7. FLEXIBLE METAL CONDUIT CONNECTION TO MOTORS, TRANSFORMERS AND OTHER VIBRATING EQUIPMENT SHALL BE PERMITTED. LIGHTING FIXTURE WHIPS MAY UTILIZE FLEXIBLE METAL CONDUIT FOR CONNECTION BETWEEN HOMERUN JUNCTION BOX AND FIXTURE. 8. AUTOMATIC TRANSFER SWITCHES SHOWN THIS SHEET SHALL BE OPEN-TRANSITION, BYPASS ISOLATION TYPE. NEUTRAL CONDUCTOR SHALL BE SWITCHED. m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com KEY NOTES X Job #: 755.011 (THIS SHEET) High Performance Building Consultants HVAC SHUTDOWN, FIRE PUMP, FLOW & TAMPER SWITCHES AND PIV F 1. ] 4 # 600 4 # 400 1600A4 G 3. SETS 3 5 (THIS SHEET) ALUMINUM CONDUCTORS 1400A4 G FIRE ALARM SYSTEM RISER SHOWN THIS SHEET AND FIRE ALARM DEVICE LAYOUT SHOWN ON DRAWINGS ARE FOR GENERAL CONFORMANCE TO CODE AND TO PROVIDE A BASIS OF DESIGN. IN ADDITION TO THIS INFORMATION, CONTRACTOR'S BASE BID SHALL INCLUDE ALL SYSTEMS AND COMPONENTS AS DEEMED NECESSARY BY THE QUALIFIED FIRE ALARM SYSTEM DESIGNER. THE QUALIFIED FIRE ALARM SYSTEM DESIGNER SHALL MEET THE MINIMUM QUALIFICATIONS REQUIRED BY SPECIFICATION 283111. AUXILIARY RELAYS AND ADDRESSABLE MODULES "C SETS 1600A4 2. GENERAL NOTES SCHEDULE 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL FIRE ALARM SYSTEM NOTES 1. PROVIDE LOWER VALLEY ENERGY APPROVED CT CABINET FOR INSTALLATION OF CURRENT TRANSFORMER AND UTILITY METER. 2. PROVIDE STEEL REINFORCED CONCRETE PAD. DESIGNED BY STRUCTURAL ENGINEER AND INSTALLED BY CONTRACTOR. AT A MINIMUM, CONCRETE PAD SHALL EXTEND 1' BEYOND EQUIPMENT FOOTPRINT ON ALL SIDES. 3. DIESEL GENERATOR BASIS OF DESIGN: 480Y/277V, 800kW CUMMINS MODEL DQFAB; WEATHER-PROTECTIVE STEEL ENCLOSURE; SUPER CRITICAL MUFFLER; 2,400 GALLON UL142 DOUBLE WALL BASE FUEL TANK; PACKAGE DIMENSIONS 332" LONG x 98" WIDE x 142" HEIGHT. DIMENSIONS SHALL BE CONFIRMED WITH GENERATOR MANUFACTURER PRIOR TO INSTALLATION. 4. PROVIDE TYPE II SURGE PROTECTION DEVICE WITH MINIMUM SURGE CURRENT CAPACITY OF 250kA PER PHASE AND 125kA PER MODE. CONNECT TO MAIN SWITCHBOARD BY WAY OF CIRCUIT BREAKER DISCONNECT. 5. PROVIDE 25% PREPARED SPACE CAPACITY FOR CONNECTION OF FUTURE CIRCUIT BREAKERS. INITIATING DEVICE CIRCUITS WG NOTIFICATION APPLIANCE CIRCUITS FIRE ALARM CONTROL PANEL (FACP) 120V-20A CIRCUIT, LABEL "FIRE ALARM CONTROL PANEL" DEDICATED TELEPHONE LINE TELEPHONE LINE VIA LINE SEIZURE FIRE ALARM DIAGRAM 2 SCALE: NO SCALE L6 225A MLO 120/208V 3 -4W L3 225A MLO 120/208V 3 -4W MAINT MEZZ 800A3P (L,INST) 250A3P (INST) 150A4G CU U/G CU AL CU U/G ATS-SB1 1400A, 4-POLE 277/480V 65kAIC L SWITCHBOARD "ESB1" 1600A, 277/480V 65kAIC, 3 -4W 100A4G 150A4G ELEC RM 169 CU CU N E NOT FOR CONSTRUCTION 3 DIESEL GENERATOR 800kW-480Y/277V 1 SERVICE TRANSFORMER 480Y/277V 5 SWITCHBOARD "SB1" 1400A, 277/480V, 65kAIC, 3 -4W DESIGN DEVELOPMENT TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 50A3G AL BUS STORAGE MEZZ MAIN SWITCHBOARD "MSB1" 1600A, 277/480V, 65kAIC, 3 -4W N G M 277/480V RESISTIVE & REACTIVE LOAD BANK 2 1600A3P (LSI) AL WASH EQUIP / COMPRESSOR RM 166 100A3P AL BUS STORAGE MEZZ 150A3P (INST) AL MAINTENANCE BAY MEZZ JACKSON, WYOMING 100A4G 175A4G 70A3G ELEC RM 169 U/G 250A3P (INST) 4 SPD U/G 250A3P (INST) E 1400A3P (LSIG) AL LTG1 100A MLO 277/480V 3 -4W 150A4G T-LDP1 150kVA 480V208Y/120V LTG2 100A MLO 277/480V 3 -4W ATS-HLS 150A 4-POLE 277/480V N 65kAIC 150A3P (INST) ELEC RM 169 T HDP1 400A MLO 277/480V 3 -4W 1400A3P (LSI) AL #2 GND HDP2 800A MLO 277/480V 3 -4W 1400A4G T-LDP2 150kVA 480V208Y/120V 250A3G ELEC RM RES T HDP3 800A MLO 277/480V 3 -4W 100A4G #2 GND AL 250A3G T-LDP3 150kVA 480V208Y/120V U/G L %VD BUS STORAGE MEZZ CU CU 100A3P AL AL WASH EQUIP / COMPRESSOR RM 166 100A4G %VD T-L1 45kVA 480V208Y/120V U/G ELEC RM 169 BUS STORAGE MEZZ HLS 150A MLO 277/480V 3 -4W 100A3P ELEC RM 169 800A4G %VD T ECB-1 600A-3P (L,INST) ECB-2 600A-3P (L,INST) 800A4G 800A4G AL U/G 800A4G AL #6 GND T-LS 30kVA 480V208Y/120V CU AL %VD T WASH EQUIP / COMPRESSOR RM 166 400A4G %VD #8 GND L1 175A MCB 120/208V 3 -4W BUS STORAGE MEZZ 800A4G 800A4G MAINTENANCE BAY MEZZ BUS STORAGE MEZZ CU 225A4G LDP1 600A MCB 120/208V 3 -4W ELEC RM RES 250A3G 225A4G LDP2 600A MCB 120/208V 3 -4W LDP3 600A MCB 120/208V 3 -4W T 225A4G AL AL AL CU CU CU CU CU AL #2 GND BUS STORAGE MEZZ AL AL AL 225A4G 100A4G 100A4G 100A4G 100A4G 100A4G ELEC RM RES 225A4G L7 225A MLO 120/208V 3 -4W 225A4G R3 100A MCB 120/208V 3 -4W 225A4G MAINT MEZZ 400A3P (L,INST) R1 100A MCB 120/208V 3 -4W A 225A MLO 120/208V 3 -4W 800A3P (L,INST) R6 100A MCB 120/208V 3 -4W L4 225A MLO 120/208V 3 -4W BUS STORAGE MEZZ 400A3P (L,INST) MAINT MEZZ LS 100A MCB 120/208V 3 -4W 800A4G R2 100A MCB 120/208V 3 -4W R7 100A MCB 120/208V 3 -4W L2 225A MLO 120/208V 3 -4W G L5 225A MLO 120/208V 3 -4W BUS STORAGE MEZZ G N G 2 #6 CU GND IN 1/2"C #3/0 CU GND IN 3/4"C #3/0 CU GND IN 3/4"C CHECKED BY: Checker 4/1/2013 9:49:59 AM DRAWN BY: Author 1 METAL UNDERGROUND WATER PIPE BUILDING STEEL AL CONCRETE ENCASED ELECTRODE (UFER) D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt 1400A4G ELECTRICAL ONE−LINE DIAGRAM − BUS STORAGE AND MAINTENANCE FACILITY SCALE: NO SCALE 400A4G AL CU PRIMARY UTILITY FEEDER; COORDINATE WITH LOWER VALLEY ENERGY (LVE) 1600A4G CU CONCRETE ENCASED ELECTRODE (UFER) 1600A4 AL GROUND ROD 1400A4G 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: 3123 ELECTRICAL ONE-LINE DIAGRAM E-301 FEEDER KEY 1. 3. 30A3 G 1/2 3# 10 , 1 # 10 G 40A3 G 3/4 3# 8 , 1# 10 G 1-1/2 3# 1/0 , 1 # 6 G 2 3 # 250 , 1 # 2 G 100A4 G 1-1/2 4# 1 , 1# 8 G 150A4 G 1-1/2 4# 1/0 , 1 # 6 G 250A4 G 2-1/2 4 # 250 , 1 # 4 G 3 4 # 400 , 1 # 2/0 G 2. [ 1000A4 G 2 3 [ [ CONTRACTOR SHALL COORDINATE INSTALLATION OF SERVICE TRANSFORMER WITH LOWER VALLEY ENERGY (LVE). CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIALS AS REQUIRED BY LVE. 2. ALL CNG WIRING SHALL BE THHN/THWN INSULATED COPPER COPPER CONDUCTORS. 3. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR SIZED PER NFPA 70. A MAXIMUM OF THREE BRANCH CIRCUITS SHALL BE PERMITTED TO SHARE THE SAME HOMERUN. MULITWIRE BRANCH CIRCUITS SHALL NOT BE PERMITTED. 4. PROVIDE 4" THICK CONCRETE HOUSEKEEPING PADS FOR ALL TRANSFORMERS AND FREE STANDING ELECTRICAL ENCLOSURES. EXTEND HOUSEKEEPING PADS 6" BEYOND THE FOOT PRINT OF THE EQUIPMENT. 5. ALL WIRING SHALL BE IN CONDUIT. CONDUIT EXPOSED TO WEATHER SHALL BE HOT DIPPED, RIGID GALVANIZED STEEL. CONDUIT INSTALLED BELOW GRADE SHALL BE SCHEDULE 80 PVC. STUB-UPS FROM BELOW GRADE SHALL BE ACCOMPLISHED UTILIZING HOT DIPPED, RIGID GALVANIZED STEEL CONDUIT ELBOWS WRAPPED IN PVC TAPE. PVC CONDUIT IS NOT PERMITTED ABOVE GRADE. 6. FLEXIBLE METAL CONDUIT CONNECTION TO MOTORS, TRANSFORMERS AND OTHER VIBRATING EQUIPMENT SHALL BE PERMITTED. LIGHTING FIXTURE WHIPS MAY UTILIZE FLEXIBLE METAL CONDUIT FOR CONNECTION BETWEEN HOMERUN JUNCTION BOX AND FIXTURE. ] ] FIRE ALARM SYSTEM RISER SHOWN THIS SHEET AND FIRE ALARM DEVICE LAYOUT SHOWN ON DRAWINGS ARE FOR GENERAL CONFORMANCE TO CODE AND TO PROVIDE A BASIS OF DESIGN. IN ADDITION TO THIS INFORMATION, CONTRACTOR'S BASE BID SHALL INCLUDE ALL SYSTEMS AND COMPONENTS AS DEEMED NECESSARY BY THE QUALIFIED FIRE ALARM SYSTEM DESIGNER. THE QUALIFIED FIRE ALARM SYSTEM DESIGNER SHALL MEET THE MINIMUM QUALIFICATIONS REQUIRED BY SPECIFICATION 283111. 7. 3. ALL FIRE ALARM SYSTEM WIRING AND CABLING SHALL BE INSTALLED IN METAL CONDUIT REGARDLESS OF CODE EXCEPTIONS. 4. REFERENCE DIVISION 21 SPECIFICATIONS, DIVISION 23 SPECIFICATIONS, FIRE SUPPRESSION DRAWINGS AND MECHANICAL DRAWINGS FOR REQUIRED SEQUENCE OF OPERATIONS. 5. 120V POWER CIRCUITS FOR FIRE ALARM REMOTE POWER SUPPLIES ARE NOT SHOWN THIS FIRE ALARM RISER DIAGRAM OR ON THE DRAWINGS. QUANTITY AND LOCATIONS OF REMOTE POWER SUPPLIES SHALL BE DETERMINED BY THE QUALIFIED FIRE ALARM SYSTEM DESIGNER. 120V CIRCUITS SHALL BE PROVIDED AS REQUIRED BY FIRE ALARM SYSTEM DESIGN DOCUMENTS. COSTS ASSOCIATED WITH THESE CIRCUITS SHALL BE CARRIED IN THE CONTRACTOR'S BASE BID. AUXILIARY RELAYS AND ADDRESSABLE MODULES 1. ] 4 # 400 500A3 G PUBLIC OPERATING MODE WITH AUDIBLE AND VISIBLE NOTIFICATION VOICE/ALARM COMMUNICATIONS MANUAL FIRE ALARM SELECTIVE & SUPPLEMENTARY COVERAGE OF AUTOMATIC FIRE AND SMOKE DETECTION MONITORING OF ABNORMAL CONDITIONS ACTIVATION OF FIRE SUPPRESSION SYSTEMS ACTIVATION OF FIRE SAFETY FUNCTIONS TRANSMISSION OF ALARM SIGNALS TO OFF-SITE SUPERVISING STATION REMARK CONDUCTORS 3 5 150A3 G CONTRACTOR SHALL PROVIDE AN ADDRESSABLE ANALOG FIRE ALARM SYSTEM TO INCLUDE, AT A MINIMUM, THE FOLLOWING SYSTEM COMPONENTS AND FUNCTIONS: A. B. C. D. E. F. G. H. "C SETS THE QUALIFIED SYSTEM DESIGNER SHALL DESIGN A SYSTEM COMPLIANT WITH THE REQUIREMENTS OF IFC, NFPA, STATE OF WYOMING (AHJ), CITY OF JACKSON (AHJ), TETON COUNTY (AHJ) AND JACKSON FIRE DEPARTMENT (AHJ). 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: www.megroup.com Job #: 755.011 High Performance Building Consultants (THIS SHEET) PROVIDE LOWER VALLEY ENERGY APPROVED CT CABINET FOR INSTALLATION OF CURRENT TRANSFORMER AND UTILITY METER. 2. PROVIDE STEEL REINFORCED CONCRETE PAD. DESIGNED BY STRUCTURAL ENGINEER AND INSTALLED BY CONTRACTOR. AT A MINIMUM, CONCRETE PAD SHALL EXTEND 1' BEYOND ENCLOSURE FOOTPRINT ON ALL SIDES. 3. DIESEL GENERATOR BASIS OF DESIGN: 480Y/277V, 450kW CUMMINS MODEL DFEJ; WEATHER-PROTECTIVE STEEL ENCLOSURE; SUPER CRITICAL MUFFLER; 1,470 GALLON UL142 DOUBLE WALL BASE FUEL TANK; PACKAGE DIMENSIONS 200" LONG x 82" WIDE x 128" HEIGHT. DIMENSIONS SHALL BE CONFIRMED WITH GENERATOR MANUFACTURER PRIOR TO INSTALLATION. 4. PROVIDE TYPE II SURGE PROTECTION DEVICE WITH MINIMUM SURGE CURRENT CAPACITY OF 250kA PER PHASE AND 125kA PER MODE. CONNECT TO MAIN SWITCHBOARD BY WAY OF CIRCUIT BREAKER DISCONNECT. 5. PROVIDE 25% PREPARED SPACE CAPACITY FOR CONNECTION OF FUTURE CIRCUIT BREAKERS. WG NOTIFICATION APPLIANCE CIRCUITS X 1. INITIATING DEVICE CIRCUITS m GR UP e d e s i g n AUTOMATIC TRANSFER SWITCH SHOWN THIS SHEET SHALL BE OPEN-TRANSITION, BYPASS ISOLATION TYPE. NEUTRAL CONDUCTOR SHALL BE SWITCHED. KEY NOTES HVAC SHUTDOWN, FIRE PUMP, FLOW & TAMPER SWITCHES AND PIV F (THIS SHEET) COPPER CONDUCTORS FIRE ALARM SYSTEM SHALL BE BY DELEGATED-DESIGN SUBMITTAL. REFERENCE SPECIFICATION 283111 FOR GENERAL SUBMITTAL REQUIREMENTS. 1600A4 2. GENERAL NOTES SCHEDULE 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f GENERAL FIRE ALARM SYSTEM NOTES FIRE ALARM CONTROL PANEL (FACP) 120V-20A CIRCUIT, LABEL "FIRE ALARM CONTROL PANEL" DEDICATED TELEPHONE LINE TELEPHONE LINE VIA LINE SEIZURE FIRE ALARM DIAGRAM 30A3G 40A3G 500A3G 40A3G 100A4G 100A3P L CONTROL PANEL 600A3P (LSI) ATS-SB2 1000A, 4-POLE 277/480V 65kAIC CONTROL PANEL 500A3G CONTROL PANEL DIESEL GENERATOR 450kW-480Y/277V 1600A3P (LSIG) DISTRIBUTION BOARD "SB2" 1000A, 277/480V, 65kAIC, 3 -4W E G MAIN SWITCHBOARD "MSB2" 1600A, 277/480V, 65kAIC, 3 -4W 3 1 SERVICE TRANSFORMER 480Y/277V 5 N DESIGN DEVELOPMENT 4 SPD JACKSON, WYOMING M TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY M 1000A3P (LSI) M 70A3P (INST) T 150A3G 150A4G 500A3G 300HP COMPRESSOR T-L8 75kVA 480V208Y/120V 150A3P (INST) 150A3P (INST) 600A3P (LSI) 40A3G 70A3P (INST) CONTROL PANEL 20HP COOLER FAN 30A3G HDP4 150A MLO 277/480V 3 -4W #4 GND CONTROL PANEL GAS DRYER 25A3P M 1000A3P (LSI) M L8 250A MCB 120/208V 3 -4W 1000A4G 300HP COMPRESSOR 250A4G 20HP COOLER FAN 500A3G SCALE: NO SCALE 40A3G 2 M N G G N G 2 NOT FOR CONSTRUCTION #6 CU GND IN 1/2"C #3/0 CU GND IN 3/4"C #3/0 CU GND IN 3/4"C SCALE: NO SCALE PRIMARY UTILITY FEEDER; COORDINATE WITH LOWER VALLEY ENERGY (LVE) 1000A4G CONCRETE ENCASED ELECTRODE (UFER) METAL UNDERGROUND WATER PIPE BUILDING STEEL ELECTRICAL ONE−LINE DIAGRAM − CNG AL 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. PROJECT No: 3123 CHECKED BY: Checker ELECTRICAL ONE-LINE DIAGRAM 4/1/2013 9:50:00 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt 1 CONCRETE ENCASED ELECTRODE (UFER) 1600A4 GROUND ROD 1000A4G E-302 KEY DESCRIPTION EQUIV. LISTED LOAD HP FLA KW LOAD (VA) VOLTS NEMA DISCONNECT PH MOTOR CIRCUIT CONDUCTORS CONDUCTORS CONDUIT SWITCH FUSE STARTER SIZE SOURCE PANEL NOTES MAINTENANCE EQUIPMENT SCHEDULE EQUIP # DESCRIPTION QTY LISTED LOAD HP AHU-1 AIR HANDLER (OFFICE/ADMIN) 48 39.91 39906 480 3 3 # 4, 1 # 8 G 1 60 A 3 P 60 - HDP2 - ERV-1 ERV (BUS STORAGE) 66.4 55.2 55204 480 3 3 # 2, 1 # 8 G 1-1/4 - - - HDP2 1 ERV-2 ERV (MAINTENANCE BAY) 148.8 123.7 123710 480 3 3 # 3/0, 1 # 6 G 2 - - - HDP3 1 ERV-3 ERV (RESIDENTIAL) 64.24 23.1 23144 208 3 3 # 2, 1 # 8 G 1-1/4 - - - LDP3 1 HWP-1 HOT WATER CIRC PUMP 5 7.6 6.32 6319 480 3 3 # 12, 1 # 12 G 1/2 - - - HDP2 1 HWP-2 HOT WATER CIRC PUMP 5 7.6 6.32 6319 480 3 3 # 12, 1 # 12 G 1/2 - - - HDP2 1 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f MECHANICAL EQUIPMENT SCHEDULE FLA EQUIV. KW VOLTS PH LOAD (VA) FEEDERS DISCONNECT PANEL / CIRCUIT # CONDUCTORS CONDUIT DISC SW FUSE NOTES LUBE / COMPRESSOR ROOM #112 2165 AIR COMPRESSOR 1 25 28267 480 3 3 # 4, 1 # 8 G 1 1/4 100 A 3 P 70 2231 DRYER, AIR, REFRIGERATED 1 1-1/2 2494 480 3 3 # 12, 1 # 12 G 3/4 30 A 3 P 15 7240 FLUID MANAGEMENT SYSTEM 1 120 1 2 TIRE SHOP & STORAGE #117 HWP-3 HOT WATER CIRC PUMP 5 7.6 6.32 6319 480 3 3 # 12, 1 # 12 G 1/2 - - - HDP2 1 BP-1 MEZZANINE 1 4.6 1.67 1657 208 3 3 # 12, 1 # 12 G 1/2 - - - L2 1 24501 CHARGER, TIRE, BUS-LARGE TRUCK 1 1 49051 BALANCER, SHEEL ELECTRONIC 1 1 m GR UP e d e s i g n 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: BATTERY STORAGE #114 BP-2 MEZZANINE 1 4.6 1.67 1657 208 3 3 # 12, 1 # 12 G 1/2 - - - L2 1 BP-3 MEZZANINE 1 4.6 1.67 1657 208 3 3 # 12, 1 # 12 G 1/2 - - - L2 1 B-1 MEZZANINE 5 600 120 1 2 # 12, 1 # 12 G 1/2 - - - L2 2 B-2 MEZZANINE 5 600 120 1 2 # 12, 1 # 12 G 1/2 - - - L2 2 B-3 MEZZANINE 5 600 120 1 2 # 12, 1 # 12 G 1/2 - - - L2 2 EF-1 ADMIN TOILET ROOMS 1/2 5.4 1.12 1123 208 1 2 # 12, 1 # 12 G 1/2 20 A 2 P 10 - A - EF-2 MAINTENANCE TOILET ROOMS 1/4 5.8 0.7 696 120 1 2 # 12, 1 # 12 G 1/2 - - - L4 3 EF-3 BATTERY STORAGE 1/6 4.4 0.5 528 120 1 2 # 12, 1 # 12 G 1/2 - - - L4 3 EF-4 RESIDENTIAL TOILET ROOM 1/12 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - SEE PLANS 4 EF-5 RESIDENTIAL TOILET ROOM 1/12 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - SEE PLANS 4 EF-6 RESIDENTIAL TOILET ROOM 1/12 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - SEE PLANS 4 EF-7 RESIDENTIAL TOILET ROOM 1/12 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - SEE PLANS 4 EF-8 RESIDENTIAL TOILET ROOM 1/12 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - SEE PLANS 4 EF-9 RESIDENTIAL TOILET ROOM 1/12 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - SEE PLANS 4 EF-10 RESIDENTIAL TOILET ROOM 1/12 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - SEE PLANS 4 EF-11 RESIDENTIAL TOILET ROOM 1/12 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - SEE PLANS 4 EF-12 RESIDENTIAL TOILET ROOM 1/12 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - SEE PLANS 4 EF-13 RESIDENTIAL TOILET ROOM 1/12 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - SEE PLANS 4 EF-14 RESIDENTIAL TOILET ROOM 1/12 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - SEE PLANS 4 EF-15 RESIDENTIAL TOILET ROOM 1/12 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - SEE PLANS 4 EF-16 CNG COMPRESSOR ROOM 1/3 7.2 0.86 864 120 1 2 # 12, 1 # 12 G 1/2 - - - L8 3 20751 UH-1 WASH/EQUIP COMPRESSOR ROOM 16 120 1 2 # 12, 1 # 12 G 1/2 - - - L1 2 UH-2 WASH/EQUIP COMPRESSOR ROOM 16 120 1 2 # 12, 1 # 12 G 1/2 - - - L1 UH-3 WATER ENTRY 16 120 1 2 # 12, 1 # 12 G 1/2 - - - EUH-1 CNG COMPRESSOR ROOM 15 15000 480 3 3 # 10, 1 # 10 G 1/2 - - EUH-2 CNG ELECTRICAL ROOM 5 5000 480 3 3 # 12, 1 # 12 G 1/2 - EUH-3 CNG OFFICE 5 5000 480 3 3 # 12, 1 # 12 G 1/2 EUH-4 VESTIBULE 162 5 5000 480 3 3 # 12, 1 # 12 G EUH-5 ELEC EQUIP 168 5 5000 480 3 EUH-6 ELEC SWITCHGEAR 168 5 5000 480 GUH-1 WASH BAY 1/3 7.2 0.9 864 GUH-2 CHASSIS WASH 1/3 7.2 0.9 GF-1 GLYCOL FEEDEER TANK 1/3 7.2 DCP-1 BUILDING 1/12 SCP-1 SOLAR DHW 1/2 ESP-1 2045 CHARGER, BATTERY 2 1560 120 1 2 # 12, 1 # 12 G 3/4 2 www.megroup.com LIGHT DUTY REPAIR BAY #1, #2, #3 3466 REEL, VEHICLE EXHAUST, MOTOR OPERATED, 4" HOSE 2 57141 LIFT, SIRFACE MTD, TWIN POST, 15,000lbs 1 5716 LIFT, SIRFACE MTD, TWIN POST, 18,000lbs 1 3/4 1656 120 1 2 # 10, 1 # 10 G 3/4 30 A 1 P Job #: 755.011 25 High Performance Building Consultants 1 3 4077 208 1 2 # 8, 1 # 10 G 3/4 60 A 2 P 35 TOOL BOX STORAGE #113 7540 PUMP, DIAPHRAGM, FLUID 1 7541 PUMP, DIAPHRAGM, FLUID 1 REBUILD SHOP #101 20761 GRINDER 6" WITH PEDESTAL 1 1 22051 DRILL PRESS 1 1 23441 IRON WORKER 1 1 26901 SAW, BAND, HORIZONTAL 1 1 29141 WELDER, MIG 1 1 29151 CUTTER, PLASMA 1 1 29401 WELDER, MIG 1 1 3290 FUME EXTRACTION ARM, WELDING 1 92001 UO BURNER 1 1 BUFFER/GRINDER, BENCH MTD 1 1 21911 CRIMPER, FITTINGS/HOSE ELECTRIC 1 1 2 22201 DRILL PRESS 1 1 L1 2 23601 LATHE, BRAKE DRUM 1 1 - HDP4 6 25501 PRESS, AIR/HYDRAULIC 55 TON 1 1 - - HDP4 6 26981 SAW, CUTOFF, ABRASIVE 1 1 - - - HDP4 6 3784 WASHER, PARTS, AUTOMATIC, FRONT LOAD 1 1/2 - - - HDP1 6 7540 PUMP, DIAPHRAGM (UO) 1 3 # 12, 1 # 12 G 1/2 - - - HDP1 6 7541 PUMP, DIAPHRAGM (UC) 1 3 3 # 12, 1 # 12 G 1/2 - - - HDP1 6 120 1 2 # 12, 1 # 12 G 1/2 - - - L1 3 2340 FLOOR SCRUBBER, 28" PATH 1 864 120 1 2 # 12, 1 # 12 G 1/2 - - - L1 3 29161 WELDER, MIG 1 1 0.9 864 120 1 2 # 12, 1 # 12 G 1/2 - - - L2 3 29351 WELDER, STICK AC/DC 1 1 1 0.12 120 120 1 2 # 12, 1 # 12 G 1/2 - - - L2 5 5.4 1.123 1123 208 1 2 # 12, 1 # 12 G 1/2 - - - L2 5 3460 REEL, VEHICLE EXHAUST, MOTOR OPERATED, 6" HOSE 9 ADMINISTRATION ELEVATOR PIT 120 1 2 # 12, 1 # 12 G 1/2 - - - L2 3 35401 TANK, PART CLEANING 1 ESP-2 RESIDENTIAL ELEVATOR PIT 120 1 2 # 12, 1 # 12 G 1/2 - - - L7 3 5050 CRANE, BRIDGE, TOP RUNNING, 5 TON 1 WH-1 MAIN BLDG 3 120 1 2 # 12, 1 # 12 G 1/2 - - - L2 2 5691 LIFT, AXLE, SCISSOR, ADJUSTABLE, 60,000 lbs. 2 WH-2 MAIN BLDG 3 120 1 2 # 12, 1 # 12 G 1/2 - - - L2 2 5775 LIFT, PARALLELOGRAM, 75,000 lbs., 30' 1 58401 LIFT, COLUMN, MOBILE (SET OF 4), BATTERY OPERATED, 72,000 POUNDS 2 5842 LIFT, COLUMN, MOBILE (SET OF 4), BATTERY OPERATED, 72,000 POUNDS 1 58421 LIFT, COLUMN, MOBILE (SET OF 4), BATTERY OPERATED, 72,000 POUNDS 1 5861 LIFT, COLUMN, MOBILE (SET OF 6), BATTERY POWERED, WIRELESS, 108,000 POUNDS 1 COMMON WORK AREA #105 3 49 6 10192 208 1 2 # 4, 1 # 8 G 1 120 1 2 # 12, 1 # 12 G 3/4 100 A 2 P 80 PORTABLE EQUIPMENT STORAGE #131 3 HEAVY DUTY REPAIR BAY #1 - #8 1 1914 208 1 2 # 12, 1 # 12 G 3/4 30 A 2 P 15 480 3 3 # 4, 1 # 10 G 1 60 A 3 P 60 1. CONNECT SUPPLY CONDUCTORS TO VFD PROVIDED BY DIVISION 23 CONTRACTOR. 2. PROVIDE HEAVY DUTY, SINGLE-POLE TOGGLE SWITCH TO SERVE AS LOCAL DISCONNECTING MEANS. 3. PROVIDE HEAVY DUTY, SINGLE-POLE, FRACTIONAL HORSEPOWER MANUAL STARTER WITH OVERLOAD PROTECTION. SIZE PER NAMEPLATE RATING OF UNIT. 4. CONNECT TO DEDICATED TOGGLE SWITCH. GANG WITH TOILET ROOM LIGHTING SWITCH. 1 1 5. UNIT PROVIDED WITH SUPPLY CORD AND NEMA 5-20P PLUG. 6. UNIT PROVIDED WITH FACTORY INSTALLED DISCONNECT SWITCH. CHASSIS WASH #133 5775 LIFT, PARALLELOGRAM, 75,000 lbs., 30' 37181 WASHER, HI PRESSURE/HOT WATER, HG 1 20 22447 480 3 3 # 4, 1 # 10 G 1 60 A 3 P 60 1 VEHICLE DRIVE AISLE #136 FLOOR, SCRUBBER, RIDING 2341 1 3 BUS WASH #153 3841 WASHER, TWO BRUSH, DRIVE-THROUGH 1 WASH EQUIP/COMPRESSOR #166 MAIN CONTROL PANEL 1 15 480 3 3 # 12, 1 # 12 G 3/4 RECYCLING/PUMP CONTROL PANEL 1 60 480 3 3 # 6, 1 # 10 G 1 BLOWER CONTROL PANEL 1 125 480 3 3 # 1, 1 # 6 G 1 1/2 OZONE GENERATOR 1 15 120 1 2 # 12, 1 # 12 G 3/4 480 3 3 # 10, 1 # 10 G 3/4 120 1 2 # 12, 1 # 12 G 3/4 DESIGN DEVELOPMENT 22447 JACKSON, WYOMING 20 NOTES: TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 1 WASH EQUIP/COMPRESSOR #166 2161 COMPRESSOR, AIR RECEIVER MTD, 10HP DUPLEX 1 2228 DRYER, AIR, REFRIGERATEDM 100CFM 1 10 11639 0.93 30 A 3 P 25 NOTES: NOT FOR CONSTRUCTION 1. EXISTING EQUIPMENT - VERIFY EXACT REQUIREMENTS 2. PROVIDE DEDICATED DUPLEX RECEPTACLE FOR CONNECTION TO EQUIPMENT 3. PROVIDE CONNECTION FOR BATTERY CHARGER - VERIFY REQUIREMENTS WITH VENDOR 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker ELECTRICAL SCHEDULES 4/1/2013 9:50:01 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: E-601 RESIDENTIAL & ADMINISTRATION LUMINAIRE SCHEDULE EXTERIOR LUMINAIRE SCHEDULE MANUFACTURER DESCRIPTION AA2 TYPICAL LOCATION 2' X 2' LED TROFFER OR APPROVED CATALOG SERIES NUMBER LAMPS EQUIVALENT OR APPROVED EQUIVALENT (QTY) TYPE CREE AR22 3500 K LED VOLTAGE MOUNTING R 120-277 S P NOTES 2' X 4' RECESSED LAY-IN TROFFER NULITE G2-232T8-UNIV 2 - 32T8 OR APPROVED CATALOG SERIES NUMBER LAMPS INPUT EQUIVALENT OR APPROVED EQUIVALENT (QTY) TYPE WATTS LED 154 UNIVERSAL X 206 UNIVERSAL X 412 UNIVERSAL X 309 UNIVERSAL X 50 UNIVERSAL X 46 UNIVERSAL X 54 UNIVERSAL 15 UNIVERSAL W X 1 SS1 POLE MOUNTED LED LUMINAIRE WITH ONE HEAD, 2 LIGHT SQUARES, GLEON GLEON-AA-02-LED-E1-T3 + 20' TBF TYPE III DISTRIBUTION, MOUNTED AT 20'. 32 WATT AA3 DESCRIPTION TYPE UNIV SS2 X SURFACE MOUNT LED STRIP LIGHT AXIS BSLED-B1-500-35-AP-UNV-SC 3500K LED UNV SS3 X POLE MOUNTED LED LUMINAIRE WITH ONE HEAD, 4 LIGHT SQUARES, GLEON GLEON-AA-04-LED-E1-T4 + 20' TBF AA5 SURFACE MOUNT LED STRIP LIGHT AXIS BSLED-B1-500-35-AP-UNV-SC 3500K LED UNV SS4 X LED AA5 SURFACE MOUNT LED STRIP LIGHT AXIS BSLED-B1-500-35-AP-UNV-SC 3500K LED UNV SA1 X PENDANT MOUNTED UP/DOWN FLUORESCENT LIGHT ARCHITECTURAL LIGHTING LPLUU-S-4-IT8-R-WD 2 - 32T8 GLEON (2) GLEON-AA-04-LED-E1-T3 ROTATED OPTICS + 20' TBF UNIV SA2 X LED POLE MOUNTED LED LUMINAIRE WITH ONE HEAD, 6 LIGHT SQUARES, GLEON GLEON-AA-06-LED-E1-5WQ + 20' TBF PENDANT MOUNTED LED ADJUSTABLE RAIL MOUNTED LIGHT PHILIPS LEDINO 2700K 120 V SW3 X LED 15" X 15" RECESSED CANOPY LED FIXTURE McGRAW-EDISON LRC-B16-1-LED-E1-WST @ 9' TBF FLUORESCENT SOFFIT FIXTURE WITH T8 LAMPS METALUMEN CS3-A-N-W-W-4-B 1 - T32T8 NOTES W LED 4000 DEG. KELVIN 15" X 15" RECESSED CANOPY LED FIXTURE McGRAW-EDISON LRC-B32-4-LED-E1-WST @ 14' TBF LED m GR UP e d e s i g n 4000 DEG. KELVIN WALL MOUNTED LED FIXTURE INVUE LED ENT-C02-LED-E1-BL4 X 707 17th Street, SUITE 3000 DENVER, CO 80202 303 . 382 . 1920 T: 303 . 382 . 1930 F: 4000 DEG. KELVIN (3) 7.5W LED CC1 P 4000 DEG. KELVIN WITH WIDE SYMMETRICAL DISTRIBUTION. BB2 S 4000 DEG. KELVIN WITH WIDE SYMMETRICAL DISTRIBUTION. 500 LM/FT BB1 POLE MOUNTED LED LUMINAIRE WITH TWO HEADS HEAD, 4 LIGHT SQUARES TYPE V SQUARE WIDE DISTRIBUTION, MOUNTED AT 20'. 500 LM/FT R 4000 DEG. KELVIN PER HEAD, TYPE III ROTATED OPTICS, MOUNTED AT 20'. 500 LM/FT MOUNTING 4000 DEG. KELVIN TYPE IV DISTRIBUTION, MOUNTED AT 20'. AA4 VOLTAGE 1050 17th STREET SUITE A200 DENVER, CO 80265 303 295 1717 t 303 292 0845 f MANUFACTURER TYPE 277 V ST4 X LED STEP LIGHT COLE LIGHTING LED L612 @ 18 INCH X 3000 DEG. KELVIN www.megroup.com CC1-D FLUORESCENT SOFFIT FIXTURE WITH T8 LAMPS METALUMEN CS3-A-N-W-W-4-B 1 - T32T8 277 V X 1 GENERAL NOTES: Job #: 755.011 1. TYPICAL LUMINAIRE MOUNTING DESIGNATIONS SHALL BE "R" FOR RECESSED, "S" FOR SURFACE, "P" FOR PENDANT, AND "W" FOR WALL. 2. ALL FLUORESCENT AND LINEAR FLUORESCENT LAMPS SHALL BE 4000 DEGREES KELVIN, UNLESS OTHERWISE NOTED. CC2 GRID MOUNTED ASYMMETRIC LIGHT NULITE X-G44-CM-132-IDP2S32SC-4 1 - 32T8 UNIV X High Performance Building Consultants 3. FLUORESCENT BALLASTS SHALL BE ELECTRONIC PROGRAM START, UNLESS OTHERWISE NOTED. 4. ALL INDOOR FIXTURES WITH DOUBLE ENDED LAMPS AND CONTAINING BALLASTS THAT CAN BE SERVICED IN PLACE SHALL BE FURNISHED WITH MEANS OF DISCONNECTION AS REQUIRED BY N.E.C. ARTICLE 410.73(G). DD1 LED DOWNLIGHT WITH 50 DEGREE CUTOFF COOPER LIGHTING LDSQ4-09-ESQ4-835-4LSQ1-H 3500K LED UNIV X UNIV X UNIV X 900 LUMEN DD2 LED DOWNLIGHT WALL WASH COOPER LIGHTING LDSQ4-09-ESQ4-835-4LQOLWW1-H 3500K LED INTERIOR LUMINAIRE SCHEDULE 900 LUMEN DD3 DD4 LED DOWNLIGHT FIXED DOWNLIGHT LED DOWNLIGHT WALL WASH LUCIFER LUCIFER DL38ZP-IC-SS-9508-35-2 3500K LED DH-IC-ZF-9508-UNIVND 800 LUMEN DL38ZP-IC-SS-9508-35-2 3500K LED DH-IC-ZF-9508-UNIVND 800 LUMEN DD5 SURFACE MOUNTED RECTANGULAR BOX LIGHT FIXTURE TECH LIGHTING 700BX-L-S-CF PP1 PENDANT MOUNT SWAG SOCKETT AND LAMP LIGHTS. CEILING TECH LIGHTING SoCo-RED-SATIN NICKEL-300BHV483 MOUNTED WITH ADJUSTABLE CORD AND LIGHT LENGTHS 700TDSWG-S SWAG HOOK MANUFACTURER 6" lED PENDANT MOUNTED CYLINDER INTENSE ICCLED6-1100-35-55-SV-C-C144 UNIV X 10" FLUORESCENT RECESSED WALL WASHER ELP 118 TTWW-AK C1 (2) 13W 2GX7 120 V 3500K LED 120 V X 120/277 V X X F1 RECESSED MOUNTED BEAM 2-3/8" WIDE LED LUMINAIRE AXIS BRLED-B1-500-35-SO-S-C-UNV-DF 3500K LED F2 VERTICAL MOUNTED BEAM 2-3/8" WIDE LED LUMINAIRE AXIS BRVLED-B1-500-35-SO-8-C-UNV-DF 1 - 18W 120/277 V S1 X SMALL PROFILE SURFACE MOUNTED OPAL ACRYLIC LENSE NULITE 17-1-32T8-UNV CABLE MOUNTED ADJUSTABLE LED FIXTURE OR APPROVED EQUIVALENT C6L1520-DL-35K-CCD-P-C6L20-N TRANSIT CENTER OFFICE 4' FLUORESCENT STRIP FIXTURE WITH WIREGUARD AND CHAIN HANGERS 4' FLUORESCENT STRIP FIXTURE WITH ACRYLIC LENS AND WET LOCATION (QTY) TYPE R LED 120 3500 DEG. KELVIN 277 NOTES MOUNTING S P W X METALUX 2-AC2-232-BP-UNV (2) 32W T8 UNIVERSAL EQUIPMENT ROOMS METALUX SNF-232-UNV-WG/SNF-4FT-CHAIN (2) 32W T8 UNIVERSAL WASH/WET ROOMS METALUX VT2-232-LEX-UNV-WL (2) 32W T8 UNIVERSAL BUS PARKING AND MAINTAINANCE ALBEO LED UNIVERSAL X UNIVERSAL X X X 3500K LED 3500K LED 1 - 32T8 X LED MODULE HIGH BAY FIXTURE WITH STANDARD 120 DEGREE OPTICS, HX-2-ST-4H-U2-1-0 TECHNOLOGIES 4000 DEG. KELVIN HIGH CRI UNI S2 X LED MODULE HIGH BAY FIXTURE WITH STANDARD 120 DEGREE OPTICS, BUS PARKING AND MAINTAINANCE ALBEO HX-6-ST-4H-U2-1-0 TECHNOLOGIES 6 MODULES, AND DIMMING CONTROL LED 4000 DEG. KELVIN HIGH CRI UNI X V1 UNV V2 X 4' FLUORESCENT EMERGENCY STRIP FIXTURE WITH TAMPERPROOF LOCATIONS WITH LED HOUSING, LENS, AND BATTERY BCK-UP GENERAL LIGHTING INDOOR/OUTDOOR LED EMERGENCY LIGHT FIXTURE WITH WET LOCATION EXTERIOR EXITS ATLITE FTP-2-32 (2) 32W T8 120 X X X 277 ISOLITE ELEC-EM-BZ-H1 LED LISTING, BATTERY BACK-UP, COLD WEATHER RATING, AND SELF FLUORESCENT LUMINAIRE TT1 2' X 4' RECESSED INDIRECT/DIRECT FLURESCENT FIXTURE WITH FROSTED ACRYLIC LENS, SHIELDING, AND DIMMING CONTROL 2 MODULES, AND DIMMING CONTROL 500 LM/FT SS1 LIGHTOLIER VOLTAGE LISTING 500 LM/FT RR3 ALL LOCATION TYPES LAMPS A19 8W TRIPLE TUBE RR2 6" RECESSED LED DOWNLIGHT WITH COMFORT CLEAR DIFFUSE CATALOG SERIES NUMBER REFLECTOR 1100 LUMENS RR1 OR APPROVED EQUIVALENT A2 700TDMRD-11-S MINI CANOPIE PP2 TYPICAL LOCATION DESCRIPTION TYPE 120 X 277 DIAGNOSTICS TECH LIGHTING 700KHELLO-3-SATIN ALUMINUM 1 - MR16 120 V W1 X LED EXIT SIGN WITH GREEN LETTERS WHITE HOUSING, AND SELF ALL LOCATION TYPES SURE-LITES WASH/WET ROOMS ISOLITE LPX-6-SD LED UNIVERSAL X X X MAX-AC-G-X-WW-XX-SD LED UNIVERSAL X X X DIAGNOSTICS, NUMBER OF FACES, MOUNTING, AND CHEVRONS PER PLANS WW1 DECORATIVE LED WALL SCONCE ARCHITECTURAL LIGHTING CAS-6 WATT LED-ID-REM-277-AL 3500k LED 277 V X 6W MR-16 LED WW2 3 LIGHT BATH LIGHT SATIN NICKEL FINISH PHILIPS F479036 12v BIPIN GY6.35 W2 LED EXIT SIGN WITH GREEN LETTERS, WHITE HOUSING, SELF DIAGNOSTICS AND WET LOCATION LISTING, NUMBER OF FACES, MOUNTING, AND CHEVRONS PER PLANS 120 V X GENERAL NOTES: 1. TYPICAL LUMINAIRE MOUNTING DESIGNATIONS SHALL BE "R" FOR RECESSED, "S" FOR SURFACE, "P" FOR PENDANT, AND "W" FOR WALL. 2. ALL FLUORESCENT AND LINEAR FLUORESCENT LAMPS SHALL BE 3500 DEGREES KELVIN, UNLESS OTHERWISE NOTED. WW3 DECORATIVE LED WALL SCONCE ARCHITECTURAL LIGHTING CAS-6 WATT LED-ID-REM-277-AL 3500k LED 277 V X (2) 39W T5 120 V X 32700K LED 120 V X CFQ13W/G24Q 277 V X 3500K LED 120 V X 277 V X 6W MR-16 LED WW4 RECTANGULAR MIRROR SURROUNDED BY COVE OF LIGHT TECH LIGHTING 700BCSIB-R-S-CF WW5 BEDSIDE WALL LED SCONCE READING LIGHT CERNOGROUP LEVO 30-120-H 3. FLUORESCENT BALLASTS SHALL BE ELECTRONIC PROGRAM START, UNLESS OTHERWISE NOTED. 4. ALL INDOOR FIXTURES WITH DOUBLE ENDED LAMPS AND CONTAINING BALLASTS THAT CAN BE SERVICED IN PLACE SHALL BE FURNISHED WITH MEANS OF DISCONNECTION AS REQUIRED BY N.E.C. ARTICLE 410.73(G). HESS AMERICA XXL1 LINEAR LED EXTERIOR SIGNAGE LIGHT VISUAL LIGHTING TECHNOLOGIES CS150-13-7-A-SG ELL-2SL-2545-35-AL-PG- 5.5W/FT XXW2 BRONZE LED SLIM WALL PACKS RAB LIGHTING SLIM18Y 3000K LED 18W XXW3 EXTERIOR FLUORESCENT BOLLARD WITH SINGLE SIDE LIGHT BEGA 8844P 24W FL T5HO UNIV 70W MH PAR30 277 V 3000k LED 277 V OUTPUT XXW4 IID1 EXTERIOR GROUND MOUNTED FLAG POLE LIGHT PHILIPS LED 6-1/4" IN GROUND LUMINAIRE COOPER LIGHTING SL-23-70MH-277-SPT-ADA-NA-HL 696-6LED3041-277/12-CS 6LED3041 GENERAL NOTES: A TYPICAL LUMINAIRE MOUNTING DESIGNATIONS SHALL BE "R" FOR RECESSED, "S" FOR SURFACE, "P" FOR PENDANT, AND "W" FOR WALL. B ALL FLUORESCENT AND LINEAR FLUORESCENT LAMPS SHALL BE 3500 DEGREES KELVIN, UNLESS OTHERWISE NOTED. C FLUORESCENT BALLASTS SHALL BE ELECTRONIC PROGRAM START, UNLESS OTHERWISE NOTED. D ALL INDOOR FIXTURES WITH DOUBLE ENDED LAMPS AND CONTAINING BALLASTS THAT CAN BE SERVICED IN PLACE SHALL BE FURNISHED WITH MEANS OF DISCONNECTION AS REQUIRED BY N.E.C. ARTICLE 410.73(G). PROJECT NOTES: 1 PROVIDE 0-10 VOLT DIMMING DESIGN DEVELOPMENT WALL MOUNTED SQUARE COMPACT FLUORESCENT LUMINAIRE JACKSON, WYOMING WW6 TOWN OF JACKSON START BUS MAINTENANCE & OPERATIONS FACILITY 75 LUMENS NOT FOR CONSTRUCTION 1 DESIGN DEVELOPMENT 4/18/13 No REVISION/SUBMISSION DATE COPYRIGHT 2013 - RNL. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of RNL. 3123 CHECKED BY: Checker ELECTRICAL SCHEDULES 4/1/2013 9:50:02 AM DRAWN BY: Author D:\My Data\My Revit Projects\MEG-START_MEP_2013_paul.plewczynski.rvt PROJECT No: E-602