Mercmaster LED IMPROVING INDUSTRIAL LIGHTING WITH TODAY’S TECHNOLOGY 1 THE FUTURE OF LIGHTING HAS ARRIVED • Light‐emitting diodes are not a particularly new technology • LED were first used as a replacement for incandescent lamps in indicator lamps on electronic equipment • The first breakthrough that paved the way for modern LEDs was found in 1992 2 CONVENTIONAL LAMPS VS. LED – ENERGY CONSUMPTION AND SAVINGS Significant energy reduction from all categories with LED 3 LIGHT SOURCE LAMP LIFE COMPARISON 4 UNDERSTANDING LED LANGUAGE Junction Temperature • The critical part for temperature of an LED is the “T junction” • “T junction” is the location which determines the temperature code (T rating). The “T junction” also determines the life of the LED. • Dissipating the heat via heatsinks becomes the best solution 5 UNDERSTANDING LED LANGUAGE Color Correlated Color Temperature (CCT) measures the shade of white light: • “Warm” white light: 3200 K and below • “Cool” white light: 4000 K and above • Appleton’s Mercmaster fixtures test at 5650 K 6 UNDERSTANDING LED LANGUAGE Color Color Rendering Index (CRI) measures the ability to accurately render the color of illuminated objects CRI Color Rendering Examples 75‐100 Excellent Incandescent, Halogen, Induction 60‐75 Good LED, Pulse Start Metal Halide 0‐60 (not suitable for color critical applications) Poor High Pressure Sodium 7 UNDERSTANDING LED LANGUAGE Device Efficiency / Efficacy • Efficiency is the ratio of total lumens exiting the fixture to the total lumens initially produced by the light source • Efficacy is how well a light source produces visible light • lumens per watt (LPW or lm/w) • HID/fluorescent efficacy should be calculated based on luminaire lumen (Efficiency) • LED has minor loss, considered 100% efficient BULB: HID lamps emit light in every direction; this light is controlled using a reflector or refractor. The result is poor utilization efficiencies. LED: LED directs the light to where it’s needed without the use of external optics. 8 UNDERSTANDING LED LANGUAGE Equivalent to Mercmaster III KPBU175PMT, 175W PSMH lamp with KR2ST Dome Reflector Mounting Height 12ft – 4 meters Initial Lamp lumen: 17,500 Luminaire lumen: 12,652 System watts: 198W Mercmaster LED MLEDN17P5BU Mounting Height 12ft – 4 meters Luminaire lumen: 6,075 System watts: 74W 9 UNDERSTANDING LED LANGUAGE Equivalent to FEB236BUSN 2 x 36W fluorescent Mounting Height 10ft – 3 meters Initial Lamp lumen: 5,510 Luminaire lumen: 4,433 System watts: 72W Mercmaster LED MLEDN10P5BU Mounting Height 10ft – 3 meters Luminaire lumen: 3,450 System watts: 48.5W 10 LED TESTING COMPLIANCES IES LM 79‐08: Electrical and photometric testing of solid state lighting IES LM‐80‐08: Measuring lumen maintenance of LED light sources IES TM‐21: Projecting long‐ term lumen maintenance of LED light sources IES‐approved method that describes the procedures to be followed in performing reproducible measurements: IES‐approved for measuring lumen maintenance and evaluating operating conditions for LED light sources Provides recommendations for projecting long term lumen maintenance of LED light sources using data obtained per IES LM‐80‐08 1. Total luminous flux (fixture lumens) 2. Luminous efficacy (lm/W) • Operating for at least 6,000 hours at representative operating temperatures 3. Luminous intensity & distribution (candelas) • Photometric data collected at a minimum of every 1,000 hours 4. Color characteristics: • Chromaticity, color temperature, color rendering • Chromaticity – quality of color, independent of brightness • Correlated Color Temperature (CCT) – in kelvins • CRI with 100 defined as black body radiator or daylight The result: Projection of lumen degradation or LED’s operating life in accordance to LM‐80 The result: Photometric reports for long term lumen maintenance The result: Solid‐state lighting photometric reports (absolute) 11 ADVANTAGES OF LED LIGHTING LED lighting is revolutionizing the lighting industry • LED is environmentally sound: No mercury content, no UV or IR, and a much smaller carbon footprint • LED lowers energy costs: Greater lighting efficacy and efficiency and uses far less power than traditional lighting sources • LED lowers maintenance costs: 60,000+ hours between replacements • LED is perfect for demanding environments: Solid‐state resistance to vibration and shock • LED is efficient: Directional light source without the use of external optics • LED is ready when you are: Instant‐on and cold‐start capable at –40°C, with no degradation of lumen output 12 Appleton’s LED Design Advantages 13 APPLETON’S LED DESIGN ADVANTAGES OPTIMIZED NEW FIXTURES • Wide range of LED products for most applications (70‐250W) • • • • Compact light weight design • • • Fewer LEDs and provides higher efficacy Original Mercmaster LED Increased drive current to 700mA • • • • 11.4lbs(5.2kg) lighter (22lbs/10kg down to 10.6lbs/4.8kg) New one piece design Upgraded the LEDs • • Plant retrofits now easily done Uses the same mounting hood as the MMIII Same electrical wiring for HID fixtures with lower electrical rating Same current as Areamaster LED Improved fin design to keep dust and debris out Supplied with terminals which allows for easy wiring Certifications and Compliances will include NEC/CEC • cCSAus • Class I, Div 2, Group A, B, C, D • Class I, Zone 2, Group IIC • Class II, Div 1, Group E, F,G • Class II, Div 2 Group F,G • Class III • Wet Locations and Marine (Salt Water) • Type 3R & 4X • IP66 IECEx/ATEX ‐ Pending • Zone 2 and 22 • II 3 GD • Ex nA II • Ex t IIIC • IP66 NEW Mercmaster LED MERCMASTER LED LINE EXPANSION Equivalent to HPS/PSMH MLEDN70 MLEDN10 MLEDN15 MLEDN17 MLEDN25 70W 100W 150W 175W 250W Voltage Range BU: 120‐277VAC 50/60Hz BH: 347‐480VAC, 50/60Hz LED Lumen 2,300 3,450 4,850 6,075 9,455 Input Power (W) 35/33 47.5/46 61/62 74/72 95.5/92 66 71 80 82 93 ‐40⁰C – T4A 55⁰C – T4 65⁰C – T3C ‐40⁰C – T4A 55⁰C – T4 65⁰C – T4 ‐40⁰C – T4A 55⁰C – T4 ‐40⁰C – T4A 55⁰C – T4 ‐40⁰C – T4A 50⁰C – T4 >14ft/4.27m 18ft/4.88m‐ 25ft/7.62m Efficacy Ambient Temp – T Rating CCT/CRI 5650K/70 Fixture Weight (lbs and kg) Typical Mounting (ft and m) Standard Materials Lifetime 10.6lbs – 4.8Kg Max. 9ft/2.74m 8ft/2.44m‐ 12ft/3.66m 12ft/3.66m‐ 14ft/4.27m Housing – Copper‐free cast aluminum Finish – Baked gray epoxy‐clad, electrostatically applied Lens – polycarbonate 60K+ hours 15 TOOLS/RESOURCES Appleton lighting cost and savings calculator • Tool for comparing industrial lighting systems in terms of total costs and potential savings over time • Available soon at www.egseg.com Lighting Layout • Available upon request 19 MERCMASTER LED Series SEE THE FUTURE. THE MercMaster LED Pulp & paper mills | Processing plants | Chemical plants | Oil refineries SOME THINGS DON’T CHANGE. Hazardous industrial locations demand lighting fixtures that deliver utmost safety and dependable illumination for critical tasks. But some things are changing right before your eyes. Hazardous locations are increasingly responsible for energy efficiency and “green” operations to save money and precious resources. That’s why this change is huge. LED lighting has come to hazardous locations, and the Mercmaster LED is setting the industry standard for safety, performance and efficiency. To control the future, you need to see it. The Appleton Mercmaster LED Series of Luminaires. | Storage areas | MANUFACTURING PLANTS | Waste & sewage treatment plants Mercmaster LED: the choice for a smart future. Why is LED the future? It’s not just about efficiency. LED lighting delivers real productivity benefits. • Resistant to vibrations and shock. • Directional light can improve efficiency, productivity and safety. • Cold start capable to -40°C and instant-on (<100ns). • Uses no mercury and its beam gives off no heat. • Promises long life, 60,000+ hours. • Delivers reduced maintenance costs. And perhaps most importantly, it’s green – offering an energy reduction up to 68% for similar luminosities compared to the PSMH (Pulse Start Metal Halide) you may be using today. Because of its all-around benefits, LED will soon be the prevalent lamp technology in manufacturing settings worldwide. Your future can start now. No LED industrial fixture surpasses the Appleton Mercmaster LED in efficiency, performance and advanced engineering. In day-to-day use, installation and maintenance, the Appleton Mercmaster LED’s superior design simply shines. In areas requiring better visibility and instant-on illumination, the complete range of Mercmaster LEDs provide a low maintenance, energy efficient solution. Whether low temperatures or retrofit applications Appleton has the answer. FEATURES • 5 LED array choices for light levels equivalent to 70 W HPS/PSMH, 100 W HPS/PSMH, 150 W HPS/PSMH, 175 W PSMH and 250 W HPS/PSMH. • Luminaires rated for NEC/CEC environments (ATEX/IECEx pending). • Upgraded LED array provides higher efficacies. • 700mA drive current. • Ambient temperatures: — 70W equivalent: -40 ˚F to 149 ˚F/-40 ˚C to 65 ˚C — 100W to 175W equivalent: -40 ˚F to 131 ˚F/-40 ˚C to 55 ˚C — 250W equivalent: -40 ˚F to 122 ˚F/-40 ˚C to 50 ˚C LED vs. HID: The future of efficacy. • Electrical: 120-277 Vac, 50/60 Hz BULB: HID lamps emit light in every direction; this light is controlled using a reflector or refractor. The result is poor utilization efficiencies. • Supplied with terminals to allow for easier wiring. 347-480 Vac, 50/60 Hz • Resistant to low temperatures; the lumen output does not decrease. • Compact lightweight low profile design, well suited for low mounting heights. • Utilizes the same electrical wiring for HID fixtures with lower electrical ratings. • Fixture housing and mounting hoods are copperfree cast aluminum for better heat dissipation. All exposed hardware is stainless steel. LED: LED directs the light to where it’s needed without the use of external optics. • Heatsink design to keep dust and debris from accumulating on the fixture, while maintaining the rounded edges to reduce risk of injury during installation and maintenance. • Hinge design increases safety during installation and servicing, assuring 360° compression on ballast housing gasket. • Silicone rubber gasket seals out moisture, dirt and dust; stays flexible and withstands high temperatures. • High impact-resistant polycarbonate lens is threaded for easy removal. • Epoxy powder coat finish and stainless steel latch assembly are corrosion resistant. • Dark Sky Compliant: meets specifications for low glare, focused beam and avoidance of overlighting. Easier installation, easier maintenance, easier to be green – everywhere. The Appleton Mercmaster LED excels in a varied range of demanding locations. LED Testing Compliances IES LM 79-08 “Electrical and Photometric Measurements of SolidState Lighting Products” APPLICATIONS LED fixtures suitable for use in: • Marine and wet locations. • A wide range of industrial, chemical processing and other areas where flammable gases and vapors are present. • Areas of low clearance, low ceiling heights or where fixture weights must be minimized. • Hazardous locations where severe weather conditions, excessive moisture, dirt, dust, corrosive atmosphere or high ambient temperatures are encountered. An IES approved method describes the procedures to be followed in performing reproducible measurements of the following: • Total luminous flux (fixture lumens) • Luminous efficacy (lm/watt) • Luminous intensity & distribution (candelas) • Color Characteristics – Chromaticity-Quality of color, independent of brightness. – CCT-Correlated Color Temp (k) Mounting Hoods – CRI-Color Rendering Index • Six different types of mounting hoods accommodate any application requirement. The Result: Solid-State Lighting Photometric reports (Absolute). • Utilizes the same mounting hoods as the Mercmaster III Series. • Easily accommodates retrofitting. LM80-08 “Measuring Lumen Maintenance of LED Light Sources” An IES approved method covers the measurement of lumen maintenance and procedures by which LED light sources can be operated. • Operating for at least 6,000 hours at representative operating temperatures Pendant Wall • Photometric data collected at a minimum of every 1,000 hours • Chromaticity, color temperature, color rendering The Result: Photometric reports for long term lumen maintenance. Pendant Cone 25° Stanchion IES TM-21 – “Projecting Long Term Lumen Maintenance of LED Light Sources” Provides recommendations for projecting long term lumen maintenance of LED light sources using data obtained per IES LM-80-08. The Result: To project lumen degradation or LED’s operating life in accordance to LM-80. Ceiling 90° Stanchion Certifications and compliances NEC/CEC • UL Standard: UL 1598, UL 1598A, UL 8750, UL 844 • Class I, Division 2, Groups A, B, C, D • CSA Standard: C22.2 No. 250.0, C22.2 No. 137 • Class I, Zone 2, Group IIC • cCSAus • Class II, Division 1, Group E, F, G IEC/ATEX — Pending • Class II, Division 2, Group F, G • Zone 2 and 22 • Class III • II 3 GD • Type 3R, 4X • IP66 • IP66 • Ex Standards: IEC 60079-0; 60079-15; 60079-31 • Suitable for Use in Wet Locations • Marine Outside Type (Salt Water) Catalog Numbering Guide MLEDN A Mercmaster LED Series: MLEDN - NEC/CEC MLEDNA - ATEX/ IECEx 17 2 Light Level Equivalent: 70 - 70 W HPS 10 - 100 W HPS 15 - 150 W HPS 17 - 175 W PSMH 25 - 250 W HPS/ PSMH Mounting: A - Pendant C - Ceiling D - Pendant Cone R - 90º Stanchion S - 25º Stanchion W - Wall P Optical Assembly: P - Polycarbonate Globe Hub Size: 2 - 3/4” NPT 3 - 1” NPT 4 - 1-1/4” NPT stanchion 5 - 1-1/2” NPT stanchion 6 - Metric M20 Certification for ATEX/IECEx pending. Canadian Electrical Code does NOT allow fusing in hazardous locations. Fuse not CEC rated. • Heatsink enables reliable heat transfer via the die-cast, aluminum body • Protective, high impact resistant polycarbonate lens allows for easy maintenance access • 30 LEDs in internal array direct light to where it is needed without the use of external optics 5 BU H1 Voltage: BU - Universal Voltages 120-277 Vac, 50/60 Hz BH - 347-480 Vac, 50/60 Hz Light Distribution: 5 - NEMA Type 5 Symmetrical Options: F - Fusing For NEC/CEC Only: H1 - Photocontrol 120 V H2 - Photocontrol 208 V H3 - Photocontrol 240 V H4 - Photocontrol 277 V Technical Data Equivalent to HPS/PSMH MLEDN70 MLEDN10 MLEDN15 MLEDN17 MLEDN25 70 Watt 100 Watt 150 Watt 175 Watt 250 Watt Voltage Range 120 - 277 Vac, 50/60 Hz, 347 - 480 Vac, 50/60 Hz LED Lumen 2300 3450 4850 6075 9455 Input Power 35 / 33 47.5 / 46 61 / 62 74 / 72 95.5 / 92 Efficacy 66 73 80 82 99 Ambient Temperate / T Rating -40 °C / T4A 55 °C / T4 65 °C / T3C -40 °C / T4A 55 °C / T4 -40 °C / T4A 55 °C / T4 -40 °C / T4A 55 °C / T4 -40 °C / T4A 50 °C / T4 Maximum 14 ft 18 to 25 ft CCT/CRI 5650K / 70 Typical Mounting Height Maximum 9 ft 8 to 12 ft 12 to 14 ft Standard Materials Housing – Copperfree cast aluminium Finish – Baked gray epoxy powder coat, electrostatically applied Lens – Polycarbonate Fixture Weight 10.6 lbs/4.8 kgs Induction/HID/ LED Lamp Comparison LED LED LED LED LED (70 W PSMH (100 W PSMH (150 W PSMH (175 W PSMH (250 W PSMH output) output) output) output) output) 85 W QL 165 W QL 100 W HPS 175 W PSMH System Watts 85 165 130 208 35 47.5 61 74 95.5 CRI 85 80 22 62 70 70 70 70 70 Ignition 0.1 sec 0.1 sec 5 sec 10 sec Instant Instant Instant Instant Instant Warm Up 5 sec 5 sec 3 - 4 min 1.5 min Instant Instant Instant Instant Instant Re-strike 0.1 sec 0.1 sec 1 min 1 min Instant Instant Instant Instant Instant Life 100k 100k 24k+ 15k 60k+ 60k+ 60k+ 60k+ 60k+ Energy Consumption Comparison Light Source Lamp Life Comparision Energy Consumption (Watts) 300 100,000 100K 90,000 250 80,000 70,000 200 60K+ 60,000 150 50,000 40,000 100 30K 30,000 50 0 20,000 10K to 12K 10,000 70W 100W 150W 175W 250W 2x36 2x58 HID Fluorescent LED Pulse Start Metal Halide Fluorescent High Pressure Sodium 0 24K 12K to 24K 11K to 20K 1K 1K to 2K 15K to 20K Mercmaster™ LED Series Luminaires Enclosed and Gasketed Fixtures NEC/CEC Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC Class II, Division 1, Group E, F, G Class II, Division 2, Group F, G Class III NEC/CEC Simultaneous Exposure Type 3R, 4X IP66 Suitable for Use in Wet Locations Marine Outside Type (Salt Water) Applications Features Standard Materials • Mounting hoods and bodies: cast copperfree (4/10 of 1% max.) aluminium • All hardware and catch assemblies: stainless steel • Globes: polycarbonate Standard Finishes • Mounting hoods, bodies and guards: baked gray epoxy-clad finish, electrostatically applied for complete uniform protection Certifications and Compliances • NEC/CEC — UL Standard: UL 1598, UL 1598A, UL 8750, UL 844 — CSA Standard: C22.2 No. 250.0, C22.2 No. 137 — cCSAus Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 Pending Certifications and Compliances • ATEX — Gas: Zone 2 – Conforming to ATEX 94/9/CE: CE 0081 II 3 G – ATEX Protection: Ex nA II – T Rating: • 70W equivalent: T4 (+104 ºF/+40 ºC), T4 (131 ˚F/55 ˚C) T3C (149 ˚F/65 ˚C) • 100W to 175W equivalent: T4 (+104 ºF/+40 ºC), T4 (131 ˚F/55 ˚C) • 250W equivalent: T4 (+104 ºF/+40 ºC), T4 (122 ˚F/50 ˚C) — Dust: Zone 22 – Conforming to ATEX 94/9/CE: CE 0081 II 3 D – ATEX Protection: Ex t IIIC – Surface Temperature: T197.6 ºF/T92 ºC Dc – Ambient Temperature: • 70W equivalent: -40 ˚F to 149 ˚F/-40 ˚C to 65 ˚C • 100W to 175W equivalent: -40 ˚F to 131 ˚F/-40 ˚C to 55 ˚C • 250W equivalent: -40 ˚F to 122 ˚F/-40 ˚C to 50 ˚C – Index of Protection: IP66 • IECEx — Gas: Zone 2 – IEC Protection: Ex nA II – T Rating: • 70W equivalent: T4 (+104 ºF/+40 ºC), T4 (131 ˚F/55 ˚C) T3C (149 ˚F/65 ˚C) • 100W to 175W equivalent: T4 (+104 ºF/+40 ºC), T4 (131 ˚F/55 ˚C) • 250W equivalent: T4 (+104 ºF/+40 ºC), T4 (122 ˚F/50 ˚C) — Dust: Zone 22 – IEC Protection: Ex t IIIC – Surface Temperature: T197.6 ºF/T92 ºC Dc – Ambient Temperature: • 70W equivalent: -40 ˚F to 149 ˚F/-40 ˚C to 65 ˚C • 100W to 175W equivalent: -40 ˚F to 131 ˚F/-40 ˚C to 55 ˚C • 250W equivalent: -40 ˚F to 122 ˚F/-40 ˚C to 50 ˚C – Index of Protection: IP66 • Ex Standards: IEC 60079-0; 60079-15; 60079-31 Related Products • NEC, Class I, Division 2 photocells for classified use are available, see PCD2 Series. • Mounting hoods — With photocontrols are not rated IP66 1 LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION • Compact light-weight low profile design is suited for low mounting heights. • Modular design allows scores of fixture component combinations to meet installation needs. Uses same mounting hoods as Mercmaster III. • Fixture housing and mounting hoods are copperfree cast aluminium with baked epoxy finish. All exposed hardware is stainless steel. • Accommodates a wide range of voltages. • Ambient temperatures: — 70W equivalent: -40 ˚F to 149 ˚F/-40 ˚C to 65 ˚C — 100W to 175W equivalent: -40 ˚F to 131 ˚F/-40 ˚C to 55 ˚C — 250W equivalent: -40 ˚F to 122 ˚F/-40 ˚C to 50 ˚C • Electrical: 120-277 Vac, 50/60 Hz; 347-480 Vac, 50/60 Hz • Pole terminal block: 1 x 8-24 AWG; 1 x 0.75 to 6 mm2. • Hinge has high lip for added safety during installation and servicing. Hinge and bolt construction assures 360º compression at all points on ballast housing gasket for positive sealing. Swing away design of captive bolt and nut simplifies servicing. • All Mercmaster mounting hoods have provision for easy field installation of fuses in fixtures (see Fixture Unit — Electrical Specification). • NPT and metric threads standard. Lighting • Enclosed and gasketed fixtures suitable for use in: — Marine and wet locations — A wide range of industrial, chemical processing and other areas where flammable gases and vapors are present — Areas of low clearance, low ceiling heights or where fixture weights must be minimized — Non-hazardous locations where severe weather conditions, excessive moisture, dirt, dust, corrosive atmosphere or high ambient temperatures are encountered • Typical applications include: — Pulp and paper mills — Processing plants — Chemical plants — Oil refineries — Foundries — Manufacturing plants — Storage areas — Waste and sewage treatment — Parking garages — Other areas where dust, water, dirt and rough usage are a problem Mercmaster™ LED Series Luminaires Enclosed and Gasketed Fixtures NEC/CEC Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC Class II, Division 1, Group E, F, G Class II, Division 2, Group F, G Class III NEC/CEC Simultaneous Exposure Type 3R, 4X IP66 Suitable for Use in Wet Locations Marine Outside Type (Salt Water) Lighting Illustrated Features Heatsink Reliable heat transfer via the cast, epoxy powder coat aluminium body. Provides maximum heat dissipation from the LED assembly to the outside environment. Driver Assembly Utilizing non-sparking components avoiding the ignition of gases or vapors that may be present (nA). LED Chamber Protected by polycarbonate lens, allows for easy maintenance access. LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION Modular Plug between LED and driver. Terminal Blocks (Zone 2) A seven-point terminal block is provided to facilitate wiring. Terminal block accommodates wire size ranging from #8 to #24 AWG. Epoxy Finish Ballast housing, hoods and guards are copperfree aluminium with epoxy powder coat finish. Fuses Two screws secure fuse kit to mounting boss in any Mercmaster mounting hood. Fuse included. Photocell Available for all fixtures except cone and ceiling mount. Installs through knock-out in mounting hood. Provides continuous ON-OFF dusk-to-dawn control. Electrical Protection Ground wire provided to bond mounting hood to ballast housing. Safety Rounded heatsink edges prevent possible injury during installation. Cooler Operating Cone Hood Larger sloped surface sheds dusts, dirt and combustible fibers providing better heat dissipation. Mounting Hood and Globe Gaskets Silicone rubber gaskets seals out moisture, dirt and dust. Stays flexible, withstands high temperatures. Closure design assures uniform gasket compression. "Safety" High Hinge Extra-high hinge provides additional protection against accidental ballast housing disengagement during installation or maintenance. Stainless Steel Latch Assembly Captive, stainless steel latch assembly bolt and nut closes securely, resists attack of corrosive atmospheres. Swing-away design simplifies servicing. 2 Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 Mercmaster™ LED Series Luminaires Enclosed and Gasketed Fixtures NEC/CEC Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC Class II, Division 1, Group E, F, G Class II, Division 2, Group F, G Class III NEC/CEC Simultaneous Exposure Type 3R, 4X IP66 Suitable for Use in Wet Locations Marine Outside Type (Salt Water) Order using catalog numbering guide below or select catalog number from tables on following pages. Catalog Numbering Guide MLEDN A Mercmaster LED Series: MLEDN - NEC/CEC MLEDNA - ATEX/IECEx 17 2 Light Level Equivalent: 70 - 70 W HPS/PSMH 10 - 100 W HPS/PSMH 15 - 150 W HPS/PSMH 17 - 175 W PSMH 25 - 250 W HPS/PSMH 5 Optical Assembly: P - Polycarbonate Globe Hub Size: 2 - 3/4” NPT 3 - 1” NPT 4 - 1-1/4” NPT stanchion 5 - 1-1/2” NPT stanchion 6 - Metric M20 BU H1 Voltage: BU - Universal Voltages 120-277 Vac, 50/60 Hz BH - 347-480 Vac, 50/60 Hz Light Distribution: 5 - NEMA Type 5 Symmetrical Options: F - Fusing Lighting Mounting: A - Pendant C - Ceiling D - Pendant Cone R - 90º Stanchion S - 25º Stanchion W - Wall P For NEC Only: H1 - Photocontrol 120 V H2 - Photocontrol 208 V H3 - Photocontrol 240 V H4 - Photocontrol 277 V LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION IECEx/ATEX Certification pending for: Zone 2 and 22; II 3 GD. Ceiling mount luminaries are not designed to use the PCD2 photocontrol. Ceiling mounts must use an FS/FD box with a photocontrol. Contact your local sales representative for more information. 175 W Pulse Start Metal Halide only. Does not have a High Pressure Sodium equivalent. Canadian Electrical Code does NOT allow fusing in hazardous locations V. Fuse not CEC rated. Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 3 Mercmaster™ LED Series Luminaire Technical Data Enclosed and Gasketed Fixtures NEC/CEC Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC Class II, Division 1, Group E, F, G Class II, Division 2, Group F, G Class III NEC/CEC Simultaneous Exposure Type 3R, 4X IP66 Suitable for Use in Wet Locations Marine Outside Type (Salt Water) Technical Data NEC/CEC Lamp Light Level Equivalent Type LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION 100 Watt HPS 150 Watt HPS 175 Watt PSMH 250 Watt PSMH IECEx/ATEX Gas Dust Ambient Temperature (°F/°C) Supply Wire Temperature (°F/°C) Class I, Division 2/ Class I, Zone 2 104/40 140/66 T4A 131/55 167/75 T4 143/65 194/90 T3C T6 T5 104/40 140/66 T4A T6 T6 131/55 167/75 T4 104/40 140/66 T4A LED Lighting 70 Watt HPS Gas Groups Class II, Division 1 and 2 Ex II 3G Ex NA Groups T6 A, B, C, D LED T6 T6 E, F, G A, B, C, D T5 E, F, G T6 T5 T6 LED T6 A, B, C, D E, F, G 131/55 167/75 T4 T6 T5 104/40 140/66 T4A T6 T6 131/55 167/75 T4 104/40 140/66 T4A LED A, B, C, D E, F, G T6 T5 T6 LED T6 A, B, C, D 122/50 167/75 E, F, G T4 T6 T5 “T” Numbers Represent the Maximum Internal Temperature or Maximum Surface Temperature NEC/CEC “T” # T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Temp. Range (ºF) 351450 326350 301325 281300 261280 231260 216230 201215 181200 166180 161165 136160 121135 101120 86100 85 IEC “T” # T1 T2 T3 T4 T5 T6 Temp. Range (°C) 301-450 201-300 136-200 101-135 86100 85 T numbers represent the maximum internal temperature for Class I, Division 2 and Class I, Zone 2 locations designated by the NEC. T numbers represent the maximum surface temperature under a dust blanket for Class II, Division 1 and Class I, Zone 2 as designated by the NEC or Zone 2 (Gas) and 22 (Dust) locations as designated by the IEC. 4 Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 Mercmaster™ LED Series Luminaire Technical Data Enclosed and Gasketed Fixtures NEC/CEC Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC Class II, Division 1, Group E, F, G Class II, Division 2, Group F, G Class III NEC/CEC Simultaneous Exposure Type 3R, 4X IP66 Suitable for Use in Wet Locations Marine Outside Type (Salt Water) Lamp Comparison Chart Lamp Data Input Power .31 @ 120 V 35 .17 @ 277 V 33 .41 @ 120 V 47.5 .20 @ 277 V 46 .53 @ 120 V 61 .25 @ 277 V 62 .63 @ 120 V 74 .29 @ 277 V 72 .80 @ 120 V 95.5 .36 @ 277 V 92 MLEDN70 MLEDN100 MLEDN150 MLEDN175 MLEDN250 Lumens CRI Lamp Life (Hours) Color Temp CCT 2300 70 60,000+ 5650 3450 70 60,000+ 5650 4850 70 60,000+ 5650 6076 70 60,000+ 5650 9455 70 60,000+ 5650 Lighting Line Current Amps LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION Mercmaster LED Ballast and Mounting Hood Weights Description Weight in Lbs/Kg Description Weight in Lbs/Kg Description Weight in Lbs/Kg Fixture Unit 10.6/4.8 Pendant 2.25/1.0 Wall 4.00/1.8 Pendant Cone 2.50/1.1 25° Stanchion 3.25/1.5 Ceiling 3.00/1.4 90° Stanchion 3.75/1.7 Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 5 Mercmaster™ LED Series Luminaires Enclosed and Gasketed Fixtures NEC/CEC Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC Class II, Division 1, Group E, F, G Class II, Division 2, Group F, G Class III NEC/CEC Simultaneous Exposure Type 3R, 4X IP66 Suitable for Use in Wet Locations Marine Outside Type (Salt Water) LED Wattage BU/BH Lamp Wattage Equivalent Hub Size Conformance Catalog Numbers LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION Lighting Pendant — One Hub, Rigid Mounting 35/33 W 70 W HPS/PSMH 3/4 NEC/CEC MLEDNA702P5 47.5/46 W 100 W HPS/PSMH 3/4 NEC/CEC MLEDNA102P5 61/62 W 150 W HPS/PSMH 3/4 NEC/CEC MLEDNA152P5 74/72 W 175 W PSMH 3/4 NEC/CEC MLEDNA172P5 95.5/92 W 250 W HPS/MH 3/4 NEC/CEC MLEDNA252P5 35/33 W 70 W HPS/PSMH 1 NEC/CEC MLEDNA703P5 47.5/46 W 100 W HPS/PSMH 1 NEC/CEC MLEDNA103P5 61/62 W 150 W HPS/PSMH 1 NEC/CEC MLEDNA153P5 74/72 W 175 W PSMH 1 NEC/CEC MLEDNA173P5 95.5/92 W 250 W HPS/PSMH 1 NEC/CEC MLEDNA253P5 35/33 W 70 W HPS/PSMH M20 ATEX/IECEx MLEDNAA706P5 47.5/46 W 100 W HPS/PSMH M20 ATEX/IECEx MLEDNAA106P5 61/62 W 150 W HPS/PSMH M20 ATEX/IECEx MLEDNAA156P5 74/72 W 175 W PSMH M20 ATEX/IECEx MLEDNAA176P5 95.5/92 W 250 W HPS/PSMH M20 ATEX/IECEx MLEDNAA256P5 Pendant Cone — One Hub, Rigid Mounting 35/33 W 70 W HPS/PSMH 3/4 NEC/CEC MLEDND702P5 47.5/46 W 100 W HPS/PSMH 3/4 NEC/CEC MLEDND102P5 61/62 W 150 W HPS/PSMH 3/4 NEC/CEC MLEDND152P5 74/72 W 175 W PSMH 3/4 NEC/CEC MLEDND172P5 95.5/92 W 250 W HPS/PSMH 3/4 NEC/CEC MLEDND252P5 35/33 W 70 W HPS/PSMH 1 NEC/CEC MLEDND703P5 47.5/46 W 100 W HPS/PSMH 1 NEC/CEC MLEDND103P5 61/62 W 150 W HPS/PSMH 1 NEC/CEC MLEDND153P5 74/72 W 175 W PSMH 1 NEC/CEC MLEDND173P5 95.5/92 W 250 W HPS/PSMH 1 NEC/CEC MLEDND253P5 35/33 W 70 W HPS/PSMH M20 ATEX/IECEx MLEDNAD706P5 47.5/46 W 100 W HPS/PSMH M20 ATEX/IECEx MLEDNAD106P5 61/62 W 150 W HPS/PSMH M20 ATEX/IECEx MLEDNAD156P5 74/72 W 175 W PSMH M20 ATEX/IECEx MLEDNAD176P5 95.5/92 W 250 W HPS/PSMH M20 ATEX/IECEx MLEDNAD256P5 IECEx/ATEX Certification pending for: Zone 2 and 22; Suffix Voltage AC Frequency BU 120 - 277 50/60 Hz BH 347 - 480 50/60 Hz 6 II 3 GD. Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 Mercmaster™ LED Series Luminaires Enclosed and Gasketed Fixtures NEC/CEC Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC Class II, Division 1, Group E, F, G Class II, Division 2, Group F, G Class III NEC/CEC Simultaneous Exposure Type 3R, 4X IP66 Suitable for Use in Wet Locations Marine Outside Type (Salt Water) LED Wattage BU/BH Lamp Wattage Equivalent Hub Size Conformance Catalog Numbers Ceiling — Five Hubs, Four Close-up Plugs 35/33 W 70 W HPS/PSMH 3/4 NEC/CEC MLEDNC702P5 47.5/46 W 100 W HPS/PSMH 3/4 NEC/CEC MLEDNC102P5 61/62 W 150 W HPS/PSMH 3/4 NEC/CEC MLEDNC152P5 74/72 W 175 W PSMH 3/4 NEC/CEC MLEDNC172P5 95.5/92 W 250 W HPS/PSMH 3/4 NEC/CEC MLEDNC252P5 70 W HPS/PSMH 1 NEC/CEC MLEDNC703P5 100 W HPS/PSMH 1 NEC/CEC MLEDNC103P5 61/62 W 150 W HPS/PSMH 1 NEC/CEC MLEDNC153P5 74/72 W 175 W PSMH 1 NEC/CEC MLEDNC173P5 95.5/92 W 250 W HPS/PSMH 1 NEC/CEC MLEDNC253P5 35/33 W 70 W HPS/PSMH M20 ATEX/IECEx MLEDNAC706P5 47.5/46 W 100 W HPS/PSMH M20 ATEX/IECEx MLEDNAC106P5 61/62 W 150 W HPS/PSMH M20 ATEX/IECEx MLEDNAC156P5 74/72 W 175 W PSMH M20 ATEX/IECEx MLEDNAC176P5 95.5/92 W 250 W HPS/PSMH M20 ATEX/IECEx MLEDNAC256P5 Lighting 35/33 W 47.5/46 W LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION Wall — Five Hubs, Four Close-Up Plugs 35/33 W 70 W HPS/PSMH 3/4 NEC/CEC MLEDNW702P5 47.5/46 W 100 W HPS/PSMH 3/4 NEC/CEC MLEDNW102P5 61/62 W 150 W HPS/PSMH 3/4 NEC/CEC MLEDNW152P5 74/72 W 175 W PSMH 3/4 NEC/CEC MLEDNW172P5 95.5/92 W 250 W HPS/PSMH 3/4 NEC/CEC MLEDNW252P5 35/33 W 70 W HPS/PSMH 1 NEC/CEC MLEDNW703P5 47.5/46 W 100 W HPS/PSMH 1 NEC/CEC MLEDNW103P5 61/62 W 150 W HPS/PSMH 1 NEC/CEC MLEDNW153P5 74/72 W 175 W PSMH 1 NEC/CEC MLEDNW173P5 95.5/92 W 250 W HPS/PSMH 1 NEC/CEC MLEDNW253P5 35/33 W 70 W HPS/PSMH M20 ATEX/IECEx MLEDNAW706P5 47.5/46 W 100 W HPS/PSMH M20 ATEX/IECEx MLEDNAW106P5 61/62 W 150 W HPS/PSMH M20 ATEX/IECEx MLEDNAW156P5 74/72 W 175 W PSMH M20 ATEX/IECEx MLEDNAW176P5 95.5/92 W 250 W HPS/PSMH M20 ATEX/IECEx MLEDNAW256P5 IECEx/ATEX Certification pending for: Zone 2 and 22; Suffix Voltage AC Frequency BU 120 - 277 50/60 Hz BH 347 - 480 50/60 Hz II 3 GD. Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 7 Mercmaster™ LED Series Luminaires Enclosed and Gasketed Fixtures NEC/CEC Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC Class II, Division 1, Group E, F, G Class II, Division 2, Group F, G Class III NEC/CEC Simultaneous Exposure Type 3R, 4X IP66 Suitable for Use in Wet Locations Marine Outside Type (Salt Water) LED Wattage BU/BH Lamp Wattage Equivalent Hub Size Conformance Catalog Numbers NEC/CEC NEC/CEC NEC/CEC NEC/CEC NEC/CEC NEC/CEC NEC/CEC NEC/CEC NEC/CEC NEC/CEC MLEDNS704P5 MLEDNS104P5 MLEDNS154P5 MLEDNS174P5 MLEDNS254P5 MLEDNS705P5 MLEDNS105P5 MLEDNS155P5 MLEDNS175P5 MLEDNS255P5 MLEDNAS704P5 MLEDNAS104P5 MLEDNAS154P5 MLEDNAS174P5 MLEDNAS254P5 MLEDNAS705P5 MLEDNAS105P5 MLEDNAS155P5 MLEDNAS175P5 MLEDNAS255P5 LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION Lighting 25° Stanchion — One Hub 35/33 W 47.5/46 W 61/62 W 74/72 W 95.5/92 W 35/33 W 47.5/46 W 61/62 W 74/72 W 95.5/92 W 35/33 W 47.5/46 W 61/62 W 74/72 W 95.5/92 W 35/33 W 47.5/46 W 61/62 W 74/72 W 95.5/92 W 70 W HPS/PSMH 100 W HPS/PSMH 150 W HPS/PSMH 175 W PSMH 250 W HPS/PSMH 70 W HPS/PSMH 100 W HPS/PSMH 150 W HPS/PSMH 175 W PSMH 250 W HPS/PSMH 70 W HPS/PSMH 100 W HPS/PSMH 150 W HPS/PSMH 175 W PSMH 250 W HPS/PSMH 70 W HPS/PSMH 100 W HPS/PSMH 150 W H HPS/PSMH 175 W PSMH 250 W HPS/PSMH 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 35/33 W 47.5/46 W 61/62 W 74/72 W 95.5/92 W 35/33 W 47.5/46 W 61/62 W 74/72 W 95.5/92 W 35/33 W 47.5/46 W 61/62 W 74/72 W 95.5/92 W 35/33 W 47.5/46 W 61/62 W 74/72 W 95.5/92 W 70 W HPS/PSMH 100 W HPS/PSMH 150 W HPS/PSMH 175 W PSMH 250 W HPS/PSMH 70 W HPS/PSMH 100 W HPS/PSMH 150 W HPS/PSMH 175 W PSMH 250 W HPS/PSMH 70 W HPS/PSMH 100 W HPS/PSMH 150 W HPS/PSMH 175 W PSMH 250 W HPS/PSMH 70 W HPS/PSMH 100 W HPS/PSMH 150 W HPS/PSMH 175 W PSMH 250 W HPS/PSMH 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx 90° Stanchion — One Hub IECEx/ATEX Certification pending for: Zone 2 and 22; Suffix Voltage AC Frequency BU 120 - 277 50/60 Hz BH 347 - 480 50/60 Hz 8 NEC/CEC NEC/CEC NEC/CEC NEC/CEC NEC/CEC NEC/CEC NEC/CEC NEC/CEC NEC/CEC NEC/CEC ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx ATEX/IECEx MLEDNR704P5 MLEDNR104P5 MLEDNR154P5 MLEDNR174P5 MLEDNR254P5 MLEDNR705P5 MLEDNR105P5 MLEDNR155P5 MLEDNR175P5 MLEDNR255P5 MLEDNAR704P5 MLEDNAR104P5 MLEDNAR154P5 MLEDNAR174P5 MLEDNAR254P5 MLEDNAR705P5 MLEDNAR105P5 MLEDNAR155P5 MLEDNAR175P5 MLEDNAR255P5 II 3 GD. Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 Mercmaster™ LED Series Luminaire Ballast Bodies Enclosed and Gasketed Fixtures NEC/CEC Simultaneous Exposure Type 3R, 4X IP66 Suitable for Use in Wet Locations Marine Outside Type (Salt Water) NEC/CEC Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC Class II, Division 1, Group E, F, G Class II, Division 2, Group F, G Class III Fixture Unit — Electrical Specification LED Wattage BU/BH Light Level Equivalent 35 / 33 W 70 W HPS Catalog Number Current Draw Fuse Kit 120 Vac @ .31 Amps 277 Vac @ .17 Amps F3 Fixture Unit MLEDN70P5 MLEDNA70P5 70 W HPS 347 Vac @ .32 Amps 480 Vac @ .23 Amps F3 47.5 / 46 W 100 W HPS 120 Vac @ .41 Amps 277 Vac @ .20 Amps F3 100 W HPS 347 Vac @ .32 Amps 480 Vac @ .23 Amps F3 61 / 62 W 150 W HPS 120 Vac @ .53 Amps 277 Vac @ .25 Amps F3 61 / 62 W 74 / 72 W 150 W HPS 347 Vac @ .32 Amps 480 Vac @ .23 Amps 175 W MH 120 Vac @ .63 Amps 277 Vac @ .29 Amps F3 MLEDN10P5 NEC/CEC 95.5 / 92 W 175 W MH 347 Vac @ .32 Amps 480 Vac @ .23 Amps 250 W HPS/MH 120 Vac @ .80 Amps 277 Vac @ .36 Amps NEC/CEC MLEDN15P5 NEC/CEC NEC/CEC MLEDN17P5 NEC/CEC F3 F3 250 W HPS/MH 347 Vac @ .32 Amps 480 Vac @ .23 Amps MLEDN17P5 NEC/CEC MLEDN25P5 NEC/CEC MLEDN25P5 347-480 Vac, 50/60 Hz BH 120-277 Vac, 50/60 Hz BU 347-480 Vac, 50/60 Hz BH 120-277 Vac, 50/60 Hz BU 347-480 Vac, 50/60 Hz BH 120-277 Vac, 50/60 Hz BU 347-480 Vac, 50/60 Hz BH 120-277 Vac, 50/60 Hz BU 347-480 Vac, 50/60 Hz BH ATEX/IECEx F3 F3 BU ATEX/IECEx MLEDN15P5 MLEDNA25P5 95.5 / 92 W ATEX/IECEx MLEDN10P5 MLEDNA17P5 74 / 72 W ATEX/IECEx NEC/CEC MLEDNA15P5 120-277 Vac, 50/60 Hz LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION 47.5 / 46 W Voltage Suffix NEC/CEC MLEDN70P5 MLEDNA10P5 Voltage Range Lighting 35 / 33 W Conformance ATEX/IECEx NEC/CEC IECEx/ATEX Certification pending for: Zone 2 and 22; II 3 GD. Canadian Electrical Code does NOT allow fusing in hazardous locations V. Fuse not CEC rated. Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 9 Mercmaster™ LED Series Luminaire Mounting Hoods Enclosed and Gasketed Fixtures Mounting Hoods Description Hub Size Catalog Number Pendant One Hub, Rigid Mounting 3/4 KPA-75 1 KPA-100 M20 KPA-M20 3/4 KPCH-75 1 KPCH-100 M20 KPCH-M20 3/4 1 KPC-75 KPC-100 M20 KPC-M20 3/4 KPWB-75 1 M20 KPWB-100 KPWB-M20 1-1/4 KPS-125 1-1/2 KPS-150 1-1/4 KPST-125 1-1/2 KPST-150 Pendant Cone One Hub, Rigid Mounting Lighting Ceiling Five Hubs, Four Close-Up Plugs Wall LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION Five Hubs, Four Close-Up Plugs 25° Stanchion One Hub 90° Stanchion One Hub Replacement Parts Description Catalog Number Globe 59607647000 Globe Gasket — Silicone Rubber 10 KRF-GK Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 Mercmaster™ LED Series Luminaire Dimensions Enclosed and Gasketed Fixtures Dimensions in Inches/Millimeters 5.59" [142.0 mm] Depending on the length of the conduit stem 10.92" [277.36 mm] 6.66" [169.16 mm] 15.40" Dia. [391.16 mm] 15.40" Dia. [391.16 mm] Pendant Cone Mount Lighting Pendant Mount 18.63" [473.2 mm] 10.93" [277.6 mm] LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION 7.22" [183.38 mm] 4.06" [103.1 mm] 8.54" [216.9 mm] 15.40" Dia. [391.16 mm] 15.40" Dia. [391.16mm] Ceiling Mount Wall Mount 18.87" [479.3 mm] 16.93" [430.0 mm] 17.22" [437.4 mm] 15.27" [387.9 mm] 9.79" [248.7 mm] 9.25" [235.0 mm] 25° 15.40" Dia. [391.16 mm] 25° Stanchion Mount Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 15.40" Dia. [391.16 mm] 90° Stanchion Mount 11 PCD2 Series Factory Sealed Hazardous Location Photocontrol For Use in Class I, Division 2, Groups A, B, C, D Locations Maintains Class I, Division 2 rating for Mercmaster III, Mercmaster III Low Profile, Mercmaster III 50-250 and 400 Series Luminaires; Mercmaster LED Series. Class I, Division 2, Groups A, B, C, D NEMA 4X Applications Materials • Encapsulated photocontrol provides automatic dusk-to-dawn lighting control in Class I, Division 2 locations. • Typical applications include walkways, security areas and any other outdoor lighting application. • For use with Mercmaster III, Mercmaster III Low Profile, Mercmaster III 50-250 and 400 Series Luminaires; Mercmaster LED Series. • For remote mounting in FS Boxes. • Encapsulated with epoxy sealing compound • FS: aluminium Certifications and Compliances • UL Standard: 1604 – Hazardous (Classified) Locations • cULus Recognized LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION Lighting Features • Factory sealed design eliminates the need for an explosionproof enclosure. • Can be easily installed in the field. • Solid state design for performance and reliability. • Available for 120, 208, 240, or 277 volts. • 50-400 W HID, incandescent, fluorescent and LED, 50/60 Hz. • 1000 VA Voltage/Ampere • Minimum time delay: 15 seconds to eliminate nuisance tripping. • Provided with (3) 18AWG stranded leads 6”/152.4 mm in length. • Will fit through standard 1/2” knockout. Factory-Installed Photocontrol Dimensions Add to fixture catalog after voltage; i.e.: KPWBL1075MTH1. Mercmaster III wall mounting hood with photocontrol installed shown Voltage Range Suffix Designation 120 V, 50/60 Hz H1 208 V, 50/60 Hz H2 240 V, 50/60 Hz H3 277 V, 50/60 Hz H4 1.13/28.7 Photocontrol in FS Cover for Use with FS/FD Box Supplied with two stainless steel screws. For neoprene gasket, order catalog number FS-GKR-1N. Voltage Range Catalog Number 120V, 50/60 Hz FSKA-PC120D2 208-277V, 50/60 Hz FSKA-PC247D2 1.38/34.9 2.56/65.0 Photocontrol for Field Installation Max. Current Catalog Number 120 V, 50/60 Hz Voltage Range 8.3 Amp PC120D2 208-277 V, 50/60 Hz 3.5 Amp PC247D2 0.69/ 17.5 1.19/30.2 1.94/49.2 Fixtures with photocontrols are not rated IP66. 12 Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 Mercmaster™ LED Series Luminaire Photometric Data Enclosed and Gasketed Fixtures DATA SHOWN IS ABSOLUTE Zonal Lumen Summary Zone Lumens % Fixture 0-30 829 36.1 0-40 1326 57.7 0-60 2149 93.5 0-90 2292 99.7 CIE Type - Direct Plane Spacing Criteria 0-Deg 90-Deg 1.3 1.3 90° 75° 400 60° Lighting REPORT NUMBER: MLEDN70P5BU Lamps: Mercmaster LED, Class 1, Div 2, Polycarbonate Optic Candela Distribution 0.0 22.5 45.0 67.5 90.0 Flux 0 1054 1054 1054 1054 1054 5 1048 1047 1051 1047 1048 100 15 1016 1014 1016 1014 1016 287 25 977 961 941 961 977 442 35 805 779 824 779 805 497 45 583 607 603 607 583 465 55 408 425 411 425 408 358 65 185 146 139 146 185 133 75 5 5 4 5 5 9 85 1 0 0 0 1 1 90 0 0 0 0 0 800 45° 0° REPORT NUMBER: MLEDN10P5BU Lamps: Mercmaster LED, Class 1, Div 2, Polycarbonate Optic Candela Distribution 0.0 22.5 45.0 67.5 90.0 Flux 0 1580 1580 1580 1580 1580 5 1569 1568 1568 1568 1569 149 15 1509 1510 1513 1510 1509 427 25 1412 1414 1437 1414 1412 655 35 1177 1215 1171 1215 1177 748 45 934 915 893 915 934 707 55 577 588 632 588 577 527 65 228 218 195 218 228 209 75 6 7 6 7 6 13 85 0 0 0 0 0 1 90 0 0 0 0 0 15° 30° Zonal Lumen Summary Zone Lumens % Fixture 0-30 1231 35.8 0-40 1980 57.6 0-60 3213 93.5 0-90 3438 100.0 CIE Type - Direct Plane Spacing Criteria 0-Deg 90-Deg 1.2 1.2 90° 75° 550 60° 1100 45° 1650 0° Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 15° 30° 13 LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION 1200 Mercmaster™ LED Series Luminaire Photometric Data Enclosed and Gasketed Fixtures Lighting DATA SHOWN IS ABSOLUTE REPORT NUMBER: MLEDN15P5BU Lamps: Mercmaster LED, Class 1, Div 2, Polycarbonate Optic Candela Distribution 0.0 22.5 45.0 67.5 90.0 Flux 0 2208 2208 2208 2208 2208 5 2202 2195 2197 2195 2202 209 15 2137 2131 2127 2131 2137 603 25 2045 2003 1977 2003 2045 926 35 1669 1658 1735 1658 1669 1051 45 1252 1282 1297 1282 1252 988 55 836 850 838 850 834 746 65 276 307 333 307 276 298 75 16 12 11 12 16 22 85 2 1 1 1 2 2 90 1 0 0 0 1 Zonal Lumen Summary Zone Lumens % Fixture 0-30 1738 35.8 0-40 2789 57.5 0-60 4523 93.3 0-90 4844 99.9 CIE Type - Direct Plane Spacing Criteria 0-Deg 90-Deg 1.2 1.2 90° 75° 750 60° 1500 LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION 45° 2250 0° REPORT NUMBER: MLEDN17P5BU Lamps: Mercmaster LED, Class 1, Div 2, Polycarbonate Optic Candela Distribution 0.0 22.5 45.0 67.5 90.0 Flux 0 0.0 22.5 45.0 67.5 90.0 Flux 5 2739 2739 2739 2739 2739 15 2724 2724 2725 2724 2724 259 25 2660 2658 2655 2658 2660 752 35 2553 2508 2462 2508 2553 1156 45 2069 2062 2201 2062 2069 1312 55 1580 1614 1655 1614 1580 1243 65 1047 1093 1046 1093 1047 943 75 353 380 391 390 353 378 85 19 15 16 15 19 28 90 2 1 1 1 2 2 15° 30° Zonal Lumen Summary Zone Lumens % Fixture 0-30 2167 35.7 0-40 3478 57.2 0-60 5664 93.2 0-90 6072 99.9 CIE Type - Direct Plane Spacing Criteria 0-Deg 90-Deg 1.2 1.2 90° 75° 950 60° 1900 45° 2850 0° 14 15° 30° Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 Mercmaster™ LED Series Luminaire Photometric Data Enclosed and Gasketed Fixtures DATA SHOWN IS ABSOLUTE Zonal Lumen Summary Zone Lumens % Fixture 0-30 3326 35.2 0-40 5372 56.8 0-60 8844 93.5 0-90 9445 99.9 CIE Type - Direct Plane Spacing Criteria 0-Deg 90-Deg 1.2 1.2 90° 75° 1450 60° Lighting REPORT NUMBER: MLEDN250P5BU Lamps: Mercmaster LED, Class 1, Div 2, Polycarbonate Optic Candela Distribution 0.0 22.5 45.0 67.5 90.0 Flux 0 4206 4206 4206 4206 4206 5 4170 4182 4177 4182 4170 397 15 4035 4046 4038 4046 4035 1145 25 3913 3888 3829 3888 3913 1784 35 3211 3233 3380 3233 3211 2046 45 2484 2524 2532 2524 2484 1942 55 1710 1763 1708 1763 1710 1530 65 682 564 606 564 682 568 75 20 18 17 18 20 31 85 2 1 1 1 2 2 90 1 1 0 1 1 2900 45° LIGHTING: ENCLOSED AND GASKETED — AREA — LED/INDUCTION 4350 0° Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 15° 30° 15 Areamaster™ Green LED Flood/High Bay Luminaires General Duty Marine Outside Type (Salt Water) Wet Locations Type 4X IP66 Applications • Locations where a green light is required to see flaws on steel. Features • LED color: green. • Compact in size, attractively styled contemporary design, rugged and dependable. • Easy to install and service. • One-piece housing. • One-piece lens cover. Secured by four M6 captive stainless steel slotted hex-head bolts. • Thermal shock and impact resistant glass lens. • Heavy duty, high temperature silicone rubber gasket, firmly seated. • Floodlight Mounting: — Yoke mount, zinc plated steel yoke with architectural bronze polyester finish. • High Bay Mounting: — (1) Conduit entry on back of luminaire. — Rotate yoke up or remove. • Vibration rated in all configurations. • Cool operating temperatures translate into long luminaire life. • Total of three (3) 3/4" NPT entries with integral bushings. • Two (2) aluminum close up plugs provided. • Electrical: 120-277 Vac, 50/60 Hz. • Nominal input power: 165. • Maximum input Amps: 1.40 - 0.60. • Power factor: > 0.90. • Terminal block (screw type for secure connection) can accept 24-10 AWG wire. Floodlight High Bay • Ballast housing and lens door: copperfree (4/10 of 1% max.) aluminum • Gasket: silicone rubber • Reflector: metallized high reflectance finish • Yoke mount: zinc plated steel • Bolts: stainless steel • Plugs: (2) aluminum provided Standard Finishes • Housing, lens cover and yoke mount: architectural bronze polyester Lighting LIGHTING: GENERAL LIGHTING — AREA — FLOODLIGHTS Standard Materials 1386 Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 Areamaster™ Green LED Flood/High Bay Luminaires General Duty Marine Outside Type (Salt Water) Wet Locations Type 4X IP66 Line Voltage Yoke Mount Catalog Number 120-277 50/60 Hz AMLED77YBUGR Accessories Description Catalog Numbers Crossarm Mounting Bracket Has 180° horizontal adjustment — degree marked. Facilitates mounting floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed, architectural bronze polyester finish. G-AM-8-CA Used with G-AM-8-CA. Clamps to 1” to 2-1/2” pipe, vertical or horizontal, or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts. Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster finish. G-AM-8-WB Slip-fits 1-1/2” or 2” pipe size poletop tenons. Includes floodlight yoke bolts, 3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate sealed, with cast aluminum cap. Assembly has architectural bronze polyester finish. G-SF20 Slip-fits 2” or 2-1/2” poletop tenons. Includes floodlight yoke bolts, 3 locking bolts, and cord grip. Malleable iron, zinc plated, chromate sealed, with architectural bronze polyester finish. G-AM-8-SF Pipe or Wall Mount Bracket Poletop Slip-Fitter LIGHTING: GENERAL LIGHTING — AREA — FLOODLIGHTS Poletop Slip-Fitter Lighting Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 1387 Areamaster™ Green LED Flood/High Bay Luminaire Dimensions General Duty Dimensions in Inches/Millimeters Floodlight 15.30 in./388.6 mm 3.70 in./93.9 mm 7.20 in2/ 4645.2 mm2 14.10 in./ 358.1 mm Conduit Entry (Pendant Mount) 15.40 in./ 391.2 mm Set Screw 5.70 in./ 144.78 mm (4) Yoke Bolts 2.25 in./ 57.2 mm Conduit Entry Yoke 3.64 Turning Radius 180° Rotation (3) hubs for 3/4" NPT Conduit 4.83 in./ 122.7 mm 3.50 in./ 88.9 mm 1.75 in./ (3) Mounting Holes 44.45 mm 0.56 Dia. 3.50 in./88.9 mm LIGHTING: GENERAL LIGHTING — AREA — FLOODLIGHTS High Bay Pendant Mount Lighting 6 in./ 152.4 mm 1388 Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 Areamaster™ Green LED Flood/High Bay Luminaire Photometrics General Duty DATA SHOWN IS ABSOLUTE REPORT NUMBER: AMLED77YBUGR Fixture: Flood Mount, Led Board 60 LED, Specular Reflector 6-1/2 X 6-1/2 Tapered To 3-1/2 X 3-1/2 , Lens Clear 7 x 7" Floodlight Characteristics IES Type 7H X 7V Maximum Candlepower 3424. AT 22.5 H, 25.5 V Horizontal Beam Angle (50%) 101.5 deg Vertical Beam Angle (50%) 100.3 deg Horizontal Field Angle (10%) 134.6 deg Vertical Field Angle (10%) 134.2 deg Beam Lumens (Efficiency) 6436. (79.7) Field Lumens (Efficiency) 7949. (98.4) Total Lumens (Efficiency) 8075. (100.0) Plot(s) is/are single sweep(s) — Stray light is NOT accounted for. Lateral trace thru 90 deg Vertical. Axial Candlepower Deg Horizontal Deg Vertical 90.0 0. 90.0 0. 85.0 20. 85.0 1. 22. 75.0 3. 65.0 438. 65.0 444. 55.0 147 9. 55.0 1460. 47.5 1889. 47.5 1828. 42.5 2146. 42.5 2121. 37.5 2539. 37.5 2515. 33.0 2807. 33.0 2928. 29.0 3043. 29.0 3121. 25.5 3163. 25.5 3186. 22.5 3063. 22.5 3080. 19.5 2968. 19.5 2936. 17.0 2807. 17.0 2758. 15.0 2795. 15.0 2731. 13.0 2771. 13.0 2706. 11.0 2732. 11.0 2704. 9.0 2714. 9.0 2711. 7.0 2721. 7.0 2722. 5.0 2728. 5.0 2731. 3.0 2736. 3.0 2730. 1.0 2729. 1.0 2731. 0.0 2730. 0.0 2730. LIGHTING: GENERAL LIGHTING — AREA — FLOODLIGHTS 75.0 Lighting Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 1389 Areamaster™ LED Flood/High Bay Luminaires NEC/CEC: Class I, Division 2, A, B, C, D Marine Outside Type (Salt Water) Wet Locations Type 4 and 3R Applications • Typical applications include: — Pulp and paper mills — Processing plants — Chemical plants — Oil refineries — Foundries — Storage areas — Waste and sewage treatment — Parking garages — Other areas where dust, water, dirt and rough usage are a problem Features • Compact in size, attractively styled contemporary design, rugged and dependable. • Easy to install and service. • One-piece housing. • One-piece lens hinged cover. Secured by four M6 captive stainless steel slotted hex-head bolts. • Thermal shock and impact resistant glass lens. • Heavy duty, high temperature silicone rubber gasket, mechanically secured. • Universal design for flood and highbay mounting • Floodlight Mounting: — Yoke mount, zinc plated steel yoke with architectural bronze polyester finish. • High Bay Mounting: — (1) Conduit entry on back of luminaire with locking set screw. — Rotate yoke up or remove. • Vibration rated in all configurations. • Cool operating temperatures translate into long luminaire life. • Total of three (3) 3/4" NPT entries with integral bushings. • Two (2) aluminum close up plugs provided. • Electrical: 120-277 Vac, 50/60 Hz; 347 – 480 Vac, 50/60 Hz • Terminal block (screw type for secure connection) can accept 24-10 AWG wire. Floodlight High Bay • • • • • • • • Lighting: Enclosed and Gasketed — Floodlight Standard Materials Ballast housing and lens door: aluminum Gasket: silicone rubber Reflector: polymaris metallized high reflectance finish Yoke mount: zinc plated steel Bolts: stainless steel Plugs: (2) aluminum provided Tempered glass lens Locking set screw: stainless steel Standard Finishes • Housing, lens cover and yoke mount: architectural bronze polyester Certifications and Compliances • NEC/CEC — UL Standard: UL 1598, UL 1598A, UL 8750, UL 844 — CSA Standards: C22.2 No. 250.0, C22.2 No. 137 — cULus Lighting Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © February 2012 1155 Areamaster™ LED Flood/High Bay Luminaires NEC/CEC: Class I, Division 2, A, B, C, D Marine Outside Type (Salt Water) Wet Locations Type 4 and 3R “T” Numbers Lamp Supply Wire Temp. (°F/°C) Ambient Temp. (°F/°C) NEC/CEC Class I, Division 2, Groups A, B, C, D LED 140/60 104/40 T4 “T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations “T” Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Temp. Range (˚ºF) 664842 619662 574617 538572 502536 448500 421446 394419 358392 331356 322329 277320 250275 214248 187212 185 Temp. Range (°C) 351450 326350 301325 281300 261280 231260 216230 201215 181200 166180 161165 136160 121135 101120 86100 85 Electrical Specifications Vac Hz Watts Input Power (Nom.) Input Amps (Max.) Total Harmonic Distortion Power Factor BU 120 - 277 50/60 127 1.40 - 0.60 5% - 10% > 0.90 BH 347 - 480 50/60 127 0.50 - 0.35 7.5% - 9% > 0.90 Lighting Lighting: Enclosed and Gasketed — Floodlight Voltage Range Voltage Suffix 1156 Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © February 2012 Areamaster™ LED Flood/High Bay Luminaires NEC/CEC: Class I, Division 2, A, B, C, D Class I, Zone 2, AEx NR, Ex NR IP66, 67 Marine, Wet Location Type 4X IECEx/ATEX: II 3 GD nA II IP66, 67 Line Voltage For Class 1, Division 2 Classified Duty and Marine Yoke Mount Catalog Number 120-277 50/60 Hz AMLED77YBU 120-277 50/60 Hz AMLED77YBUGR ① 347-480 50/60 Hz AMLED77YBH Accessories Description Catalog Numbers Crossarm Mounting Bracket Has 180° horizontal adjustment — degree marked. Facilitates mounting floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed, architectural bronze polyester finish. G-AM-8-CA Used with G-AM-8-CA. Clamps to 1” to 2-1/2” pipe, vertical or horizontal, or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts. Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster finish. G-AM-8-WB Slip-fits 1-1/2” or 2” pipe size poletop tenons. Includes floodlight yoke bolts, 3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate sealed, with cast aluminum cap. Assembly has architectural bronze polyester finish. G-SF20 Slip-fits 2” or 2-1/2” poletop tenons. Includes floodlight yoke bolts, 3 locking bolts, and cord grip. Malleable iron, zinc plated, chromate sealed, with architectural bronze polyester finish. G-AM-8-SF Pipe or Wall Mount Bracket Poletop Slip-Fitter Lighting ① Green LED. Nema 4X, general duty only. Non certified. Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © October 2012 Lighting: Enclosed and Gasketed — Floodlight Poletop Slip-Fitter 1157 Areamaster™ LED Flood/High Bay Luminaires NEC/CEC: Class I, Division 2, A, B, C, D Marine Outside Type (Salt Water) Wet Locations Type 4 and 3R Dimensions in Inches/Millimeters Floodlight 15.30 in./388.6 mm 3.70 in./93.9 mm 7.20 in2/ 4645.2 mm2 14.10 in./ 358.1 mm Conduit 15.40 in./ Entry 391.2 mm (Pendant Mount) Set 5.70 in./ Screw 144.78 mm 2.25 in./ 57.2 mm Conduit Entry (4) Yoke Bolts 1.75 in./ 44.45 mm 3.50 in./88.9 mm Ground Terminal Yoke 4.83 in./ 122.7 mm 3.50 in./ 88.9 mm 3.64 Turning Radius 180° Rotation (3) hubs for 3/4" NPT Conduit (3) Mounting Holes 0.56 Dia. High Bay Pendant Mount Ceiling Jct Box Set Screw Rotate Yoke Up or Remove 6 in./ 152.4 mm Areamaster LED Weight Description Weight in Lbs/Kg Fixture Unit 22.00/10.0 Lighting Lighting: Enclosed and Gasketed — Floodlight 12 in./ Required Minimum 304.8 mm Mounting Distance 1158 Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © February 2012 Areamaster™ LED Flood/High Bay Luminaires NEC/CEC: Class I, Division 2, A, B, C, D Marine Outside Type (Salt Water) Wet Locations Type 4 and 3R Floodlight Luminaire Lumens = 13138 Mounting Height = 12.00 ft, Tilt = 45° Maximum Calculated Value = 25 Fc Typical Footcandle Values 10 20 .1 fc .5 fc -20 1 fc 2 fc Distance in feet 20 fc 10 fc 5 fc 0 footcandles (fc) -10 -20 Distance in feet Floodlight Luminaire Lumens = 13138 Mounting Height = 20.00 ft, Tilt = 45° Maximum Calculated Value = 10 Fc Typical Footcandle Values 0 20 .5 fc 1 fc 2 fc -10 Distance in feet 5 fc 10 fc 2 fc 0 footcandles (fc) -10 0 24 35 803 2179 3011 3457 3969 4390 4697 4714 4765 4619 4514 4435 4338 4241 4201 4199 4186 4186 4205 4210 Degree 90 85 75 65 55 47.5 42.5 37.5 33 29 25.5 22.5 19.5 17 15 13 11 9 7 5 3 1 0 -1 -3 -5 -7 -9 -11 -13 -15 -17 -19.5 -22.5 -25.5 -29 -33 -37.5 -42.5 -47.5 -55 -65 -75 -85 -90 Vertical 0 3 57 690 2348 3017 3371 3916 4432 4785 4992 4932 4726 4452 4350 4262 4214 4183 4198 4207 4212 4212 4210 4208 4196 4179 4183 4198 4234 4262 4334 4507 4733 4925 4929 4681 4357 3845 3319 2970 2299 648 7 3 0 Distance in feet Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © February 2012 1159 Lighting: Enclosed and Gasketed — Area — HID -10 2 fc 90 85 75 65 55 47.5 42.5 37.5 33 29 25.5 22.5 19.5 17 15 13 11 9 7 5 3 1 0 Horizontal Lighting 0 Axial Candela Degree Areamaster™ LED Flood/High Bay Luminaires NEC/CEC: Class I, Division 2, A, B, C, D Marine Outside Type (Salt Water) Wet Locations Type 4 and 3R High Bay CIE Type - General Diffuse Luminaire Lumens = 13211 Polar Graph - High Bay Coefficients of Utilization - Zonal Cavity Method 4500 3000 Zonal Lumen Summary Zone Lumens 0-30 3849 % Fixture 29.1 1500 Effective Floor Cavity Reflectance 0.20 Rcc 80 Rw 70 50 70 30 10 70 50 50 30 10 50 30 30 10 50 30 10 10 50 30 0 10 0 0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 1 111 107 103 100 108 105 102 99 101 98 96 97 95 93 93 91 90 88 2 102 95 89 84 100 93 88 83 90 85 81 86 83 79 83 80 78 76 6804 51.2 3 94 84 77 71 91 83 76 71 80 74 69 77 72 68 75 71 67 65 12051 91.2 4 86 75 67 61 84 74 66 61 71 65 60 69 63 59 67 62 58 56 0-90 13196 99.9 5 79 67 59 53 77 66 58 52 64 57 52 62 56 51 60 55 51 49 90-120 4 0.00 6 73 60 52 46 71 60 52 46 58 51 45 56 50 45 55 49 45 43 90-130 6 0.1 7 68 55 46 41 66 54 46 40 52 45 40 51 45 40 50 44 39 38 90-150 11 0.1 8 63 50 42 36 61 49 41 36 48 41 36 47 40 35 45 40 35 33 90-180 14 0.1 9 59 46 38 32 57 45 37 32 44 37 32 43 36 32 42 36 32 30 0-180 13211 100.0 10 55 42 34 29 54 41 34 29 40 34 29 39 33 29 39 33 29 27 Lighting Lighting: Enclosed and Gasketed — Floodlight 0-40 0-60 1160 Visit our website at www.appletonelec.com or contact us at (800) 621-1506. © February 2012