2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0759-1 Name: 3L-759 100: DATE: JAN 19 2006 Time: 5:48:51 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 VMV High Voltage Luminaires Ordering by Components 3L VMV High Wattage Luminaires are available in components A complete luminaire consists of: I. Champ Cover (mounting module) II. VMV Ballast Housing - Include voltage and required option(s) III. Optical & Guard Components - Globe, Reflector, Refractor, Guard I. Champ Cover (Mounting Module): Type Pendant Ceiling Wall Stanchion - 25 Degree Angle Stanchion - Straight Quad-Mount Conduit 3⁄4 1 3⁄4 1 3⁄4 1 11⁄2 11⁄2 3⁄4 Cat. No. APM2 APM3 CM2 CM3 TWM2 TWM3 JM5 PM5 QM25 II. Ballast Housings. Complete catalog number must have the voltage suffix (MT shown) and any options suffixes. Lamp Type High Pressure Sodium Metal Halide Mercury Vapor Lamp Watts Catalog Number 200 250 400 70 250 400 250 400 VMVS200/MT VMVS250/MT VMVS400/MT LMVM070/MT VMVM250/MT VMVM400/MT VMVC250/MT VMVC400/MT III. Globe, Refractors, Reflectors, Guards Type Globe Globe Guard Reflector-Dome Reflector-Angle Refractor - Type 2 Refractor - Type 5 Refractor Guard High Bay Reflector/Lens Catalog Number G303 P33 RD739 RA739 GR302 GR305 P23 GRD4 US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:759)) CH0 3 L - 3 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 759 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0754-7 Name: 3L-754 3L 100: DATE: JAN 19 2006 Time: 5:48:44 PM Operator: RB 200-400W VMV High Wattage Series Champ® H.I.D. Luminaires Application: Features: ɀ Cast copper-free aluminum construction (less than 0.4 of 1% copper) and epoxy powder finish provide excellent resistance to corrosion ɀ Six mounting arrangements to suit any lighting layout – pendant, ceiling, wall bracket, angle stanchion, straight stanchion and quad-mount. ɀ Wide range of light sources and wattages to meet specifiers needs: 200, 250, 400 watt high pressure sodium (HPS); 250 and 400 watt mercury vapor (MV); 250 and 400 watt metal halide (MH) ɀ Hinged ballast housing for ease of installation and maintenance ɀ Wide choice of photometric distributions. Glass globes, glass refractors, and reflector/ lens are available ɀ All luminaires designed to perform in a 40° C ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65°C. ɀ Superior gasketing seals between the mounting module, housing, and optical assembly for optimum performance in wet and corrosive environments. ɀ Hubs with integral conduit stop and bushing to help prevent damage to field wiring during installation ɀ Low ambient capability to (–40°C) ɀ Dome and 30° angle reflectors made of bright white Krydon® material and etched Alzak® high bay reflectors provide superior reflectivity ɀ Grounding wire for safety ɀ High power factor ballasts (Min. P. F. 90%) are available in a variety of voltages to meet local area requirements. ɀ Mogul base lamp socket STIBOINFO((CRH:66008com:3L:754)) CH0 3 L - 2 1 ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (with Glass Refractor) ɀ Marine (with Globe or Glass Refractor) & Wet Locations ɀ 3, 3R, 4, 4X; IP66 Standard Materials: VMV high wattage series Champ luminaires are used: ɀ in manufacturing plants, refineries, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, and other heavy industrial applications ɀ in applications involving medium and high mounting heights ɀ in applications where energy efficient, high lumen output is required ɀ in areas in which ignitible concentrations of flammable gases or vapors will be present only due to abnormal, unusual, or accidental conditions ɀ in marine applications where water spray and corrosive atmospheres are considerations ɀ in elevated ambient temperatures often found in industrial applications ɀ in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems ɀ wherever the damaging effects of water, wind, snow, sleet, hot sun, or any combination of these elements, are problems 754 COLOR: CMYK ɀ Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%) ɀ Exterior hardware and guards – stainless steel ɀ Reflectors (dome and angle) – Krydon fiberglass-reinforced polyester material ɀ Globes – heat and impact resistant internally fluted glass ɀ Refractors – glass ɀ Reflector lens – spun Alzak aluminum, tempered glass, stainless steel door frame Standard Finishes: ɀ Copper-free aluminum – epoxy powder coat ɀ Alzak aluminum – natural ɀ Stainless steel – natural ɀ Krydon material – high reflectance white Pendant mount with globe and guard Certifications and Compliances: ɀ NEC and CEC: - Class I, Division 2, Groups A, B, C, D - with Glass Refractor - Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) - Class 1 Zone 2 ɀ IEC: - Zone 2 Ex nR IIC ɀ UL Standards: - 844, 2279 Hazardous (Classified) Locations - 1598 Luminaires - 1598A Marine Locations ɀ CSA Standards - C22.2 No. 137 ɀ IEC Standards - 60079-15 Ceiling mount with etched Alzak reflector and tempered glass lens Options: The following special options are available from the factory by adding suffix to luminaire Cat. No. Suffix to be Description Added to Cat. No. ɀ Restricted Breathting Construction . . S826‡ - Class I Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 . . . . . . . . . S826TB‡ - Furnished with terminal block crimp terminals and dedicated voltage ballasts (no MT, DT, or TT) ɀ Fused – to protect ballast and capacitors against abnormal line conditions . . . . S658†* ɀ Quartz auxilliary lighting – comes to full brightness immediately and remains lit until the HID lamp attains 60-70% of full illumination. For non-hazardous locations only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QTZ (NOTE: Quartz lamp not included use 100W single ended lamp – Q100DC, Q100CL/DC, or 100Q/CL/DC). Consult factory for top-hat limitations. ɀ Ballast-gard TM starter cutout switch – prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 200-400W HPS only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG ɀ Factory assembled with H.I.D. lamps installed for additional labor savings. . . . . . FA ɀ Top hat with stainless steel threaded insert to attach ballast housing. . . . . . . . . . . . . . S806 US: 1-866-764-5454 CAN: 1-800-265-0502 Ceiling mount with glass refractor Electrical Ratings: ɀ 120 to 600 volts and multi-tap刁 ɀ 200, 250, 400W HPS; 250, 400W MV and MH Accessories: ɀ See pages 775 to 776 for complete listing. 刁Alzak is a registered trademark of ALCOA. † Not for use in Canada. ‡Suffix S826 and S826TB cannot be used with GRD4 Reflector/Lens * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Copyright© 2006 Cooper Crouse-Hinds Zoom: 100