FIRE Conventional Panels Addressable Panels/Communication Commercial Fire/Intrusion Panels Smoke/CO/Gas Detectors Heat/Flame/Beam Detectors Duct Detectors Alarm Stations Notification Appliances & Accessories Voice Evacuation FIrE LINE CARD (ME) 3M (AX) Altronix (AS) Amseco Potter (DS) Bosch Security (BR) BRK Electronics (CO) Chemtronics (FD) Commercial Product Group (DC) Detector Electronics (DK) Ditek (DA) D & S Technologies (D8) Dual-Lite (WH) Eaton (ED) Edwards-Vigilant (ED) Edwards Signaling (EV) EVAX Systems (FN) Fenwal Controls / Kidde (FL) Fire-Lite Alarms, Inc. (FY) Functional Devices (GN) Gentex (HY) Hochiki America (H8) Honeywell Analytics (0H) Honeywell Power Products Honeywell Security (HO) HSI Fire & Safety Group (CA) Interlogix / Caddx (ES) Interlogix / ESL (SR) Interlogix / Sentrol (3K) Kidde (LE) Light Engineered Displays (L.E.D.) (LN) Linear Corp. (MA) Macurco (BW) Mier Products (MI) Mircom (5T) National Training Center (PL) Potter Electric (RE) Raco (5R) Regin (K7) (RJ) (B9) (SF) (2S) (SL) (AN) (VQ) (SK) (O6) (X6) (BK) (PU) (TF) (T8) (AD) (TH) (L3) Rixson RSG / Security Safe Awake Safety Technology, Inc. (STI) SDI Seco-Larm SigCom Silent Call Silent Knight Space Age Electronics Specified Technologies System Sensor Takex Talkaphone Tech Spray Telular Corp. (Telguard) Thermotech Uplink Security 1.800.233.6261 adiglobal.com/us 1 * As of October 2015 Fire Alarm Control Panel Comparison Chart Part Number * All panels are COA (Certificate of Approval) for NYC. MEA no longer used. System Addr. Voltage IDC/Style NAC/Style Points NAC/ Power Outputs 4-Wire Supports Alarm Alarm/ OptionRemote SD 2-Wire Verify Trouble al Aux DACT Walk AnnunTest Outputs SD Relays Relays ciator Listings & Approvals ED-FX64R 24 VDC 4,6,7+ 2/Y or 2/Z 64 3.75A 0.5A Yes Yes Yes Yes Optional Yes Yes 1,2,3,4 ED-FX64RD 24 VDC 4,6,7+ 2/Y or 2/Z 64 3.75A 0.5A Yes Yes Yes Yes Yes Yes Yes 1,2,3,4 Yes 1,2,3,4 ED-FX254R 24 VDC 4,6,7+ 2/Y or 2/Z 254 6A 0.5A Yes Yes Yes Yes Optional Yes ED-FX254RD 24 VDC 4,6,7+ 2/Y or 2/Z 254 6A 0.5A Yes Yes Yes Yes Yes Yes Yes 1,2,3,4 Yes 1,2,3,4 3.5A 0.5A Yes Yes Yes Yes Optional Yes 3.5A 0.5A Yes Yes Yes Yes Yes Yes Yes 1,2,3,4 Yes Yes Optional Yes Yes 1,2,3,4 Yes Yes Yes Yes 1,2,3,4 ED-FX3R 24 VDC 3/B ED-FX5RD 24 VDC 5/B or 2/A 2/B or 1/A ED-FX10R 24 VDC 10/B or 5/B 4/B or 2/A 7A 0.5A Yes Yes ED-FX10RD 24 VDC 10/B or 5/B 4/B or 2/A 7A 0.5A Yes Yes 2/B Yes FIRE Edwards/Kidde Fire-Lite Alarms Part Number System Addr. Voltage IDC/Style NAC/Style Points NAC/ Power Outputs 4-Wire Supports Alarm Alarm/ OptionRemote SD 2-Wire Verify Trouble al Aux DACT Walk AnnunTest Outputs SD Relays Relays ciator Listings & Approvals FL-MS2 24VDC 2:B 1:Y None 3A 0.5A Yes Yes Yes No Opt. Yes No 1, 3, 4 FL-MS4 24VDC 4:A/B 2:Y/Z None 3 to 6A 0.5A Yes Yes Yes Yes Opt. Yes Yes 1, 3, 4 FL-MS5UD3 24VDC 5:A/B 4:Y/Z None 3.0A 0.5A Yes Yes Yes Yes Yes Yes Yes 1, 2, 3, 4 FL-MS10UD7 24VDC 10:A/B 4:Y/Z None 7.0A 0.5A Yes Yes Yes Yes Yes Yes Yes 1, 2, 3, 4 FL-MS9050UD 24VDC 4, 6, 7 2:Y/Z 50 2.5A 0.3A Yes Yes Yes Yes Yes Yes Yes 1, 2, 3, 4 FL-MS9200UDLS 24VDC 4, 6, 7 4:Y/Z 198 3 to 6A 1.0A Yes Yes Yes Yes Yes Yes Yes 1, 2, 3, 4 FL-MS9600LS 24VDC 4, 6, 7 4:Y/Z 636 7A 1.5A Yes Yes Yes Yes Opt. Yes Yes 2, 3, 4, 5 FL-MS9600UDLS 24VDC 4, 6, 7 4:Y/Z 636 7A 1.5A Yes Yes Yes Yes Yes Yes Yes 2, 3, 4, 5 FL-MS25 4 2:Y 25 2.0A 1.0A Yes Yes Yes Yes Yes Yes Yes 1, 2, 3, 4 24VDC Honeywell Part Number System Addr. Voltage IDC/Style NAC/Style Points NAC/ Power Outputs 4-Wire Supports Alarm Alarm/ OptionRemote SD 2-Wire Verify Trouble al Aux DACT Walk AnnunTest Outputs SD Relays Relays ciator Listings & Approvals V32FB-9 12VDC 8/32:B 2:Y 32 2.30A 1.0A Yes Yes 1-Prod. Yes Yes Yes Yes 1, 3, 4, 5 V32FBPT 12VDC 8/32:B 2:Y 32 2.30A 1.0A Yes Yes 1-Prod. Yes Yes Yes Yes 1, 3, 4, 5 V128FBP-9 12VDC 8/128:B 2:Y 128 2.30A 1.0A Yes Yes 1-Prod. Yes Yes Yes Yes 1, 3, 4, 5 V128FBPT 12VDC 8/128:B 2:Y 128 2.30A 1.0A Yes Yes 1-Prod. Yes Yes Yes Yes 1, 3, 4, 5 V250FBP-9 12VDC 8/250:B 2:Y 250 2.30A 1.0A Yes Yes 1-Prod. Yes Yes Yes Yes 1, 3, 4, 5 V250FBPT 12VDC 8/250:B 2:Y 250 2.30A 1.0A Yes Yes 1-Prod. Yes Yes Yes Yes 1, 3, 4, 5 APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 115 FIRE Fire Alarm Control Panel Comparison Chart Potter Part Number NAC/ Power Outputs System Addr. Voltage IDC/Style NAC/Style Points 4-Wire Supports Alarm Alarm/ OptionRemote SD 2-Wire Verify Trouble al Aux DACT Walk AnnunTest Outputs SD Relays Relays ciator Listings & Approvals PL-PFC4410RC 24VDC 4A/B 4 Y/Z None 1.5 0.5A Yes No Yes Yes Opt Yes Yes 1, 2, 3, 4, 5 PL-PFC5004E 24VDC 4B/2A 2 Y/Z None 1.7 0.5A Yes Yes Yes Yes Opt Yes Yes 1, 2, 3, 4, 5 PL-PFC6030 24VDC SLC 4, 6, 7 2 Y/Z 30 3.5 Yes Yes Yes Yes Yes Opt Yes Yes 1, 3, 4 PL-PFC6075 24VDC SLC 4, 6, 7 4 Y/Z 75 5 Yes Yes Yes Yes Yes Opt Yes Yes 1, 3, 4 PL-PFC6075R 24VDC SLC 4, 6, 7 4 Y/Z 75 5 Yes Yes Yes Yes Yes Opt Yes Yes 1, 3, 4 PL-PFC6200 24VDC SLC 4, 6, 7 2 Y/Z 127254 2 Yes Yes Yes Yes Yes Opt Yes Yes 1, 3, 4 PL-PFC6800 24VDC SLC 4, 6, 7 6 Y/Z 1271016 6 Yes Yes Yes Yes Yes Opt Yes Yes 1, 3, 4 Silent Knight Part Number System Addr. Voltage IDC/Style NAC/Style Points NAC/ Power Outputs 4-Wire Supports Alarm Alarm/ OptionRemote SD 2-Wire Verify Trouble al Aux DACT Walk AnnunTest Outputs SD Relays Relays ciator Listings & Approvals SK-SK2 24VDC 2B 1:Y None 2.5A 0.5A Yes Yes Yes No Opt. Yes No 1, 3, 4 SK-SK4 24VDC 4B 2:Y None 5.0A or 2.5 0.5A Yes Yes Yes Yes Opt. Yes Yes 1, 3, 4 SK-5208 24VDC 10 - 30 4:Y None 6.0A 6.0A Total Yes Yes Yes Yes Yes Yes Yes 1, 3, 4, 6 SK-5700 24VDC SLC 4, 6, 7 2:Y 50 2.5A 2.5A Total No Yes Yes Yes Yes Yes Yes 1, 3, 4 SK-5808 24VDC SLC 4, 6, 7 4:Y 127 6.0A 6.0A Total No Yes Yes Yes Yes Yes Yes 1, 3, 4 SK-5820XL 24VDC SLC 4, 6, 7 6:Y 127 508 6.0A 5.0A Total Yes Yes Yes Yes Yes Yes Yes 1, 3, 4, 5 APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago 116 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! FIRE Conventional Panels Fire Alarm Control Panel with Built-In Sync Fire Alarm Control Panel •NAC programmable for strobe synchronization •Up to 2.5 Amps of NAC power •2 Style B (Class B) initiating device circuits •1 Style Y (Class B) notification appliance circuits Fire Alarm Control Panel •5 programmable Style B (Class B) •4 Style Y (Class B) NAC (Notification Appliance Circuit). 3 Amps of NAC power. •Built-in DACT FL-MS5UD3 (MS5UD3) •10 programmable Style B (Class B) •4 Style Y (Class B) NAC (Notification Appliance Circuit). 7 Amps of NAC power. •Built-in DACT FL-MS10UD7 (MS10UD7) FL-MS2 (MS2) GET IT GET IT NOW! Fire Alarm Communicator 4-Zone Conventional Control Panels •4 supervised monitoring inputs: (3) fixed Class B, (1) Class A or Class B •1.0 Amp NAC power. Slave or standalone. •Program via FL-PK411UD or FL-PRO411 •4 Style B (Class B) initiating device circuits •2 Style Y (Class B) notification appliance circuits •3 Amps current expandable to 6 Amps w/opt transformer. Built-in synchronization. FL-411UDAC (411UDAC) GET IT NOW! FL-MS4 (MS4) NOW! Slave Digital Alarm Communicator Transmitter •3 Class B monitoring inputs •“Dialer Runaway” prevention •12 or 24VDC operation, field selectable •Program via FL-PRO411 FL-411 (411) GET IT GET IT NOW! Slave Digital Alarm Communicator Transmitter •4 Class B monitoring inputs •“Dialer Runaway” prevention •12 or 24VDC operation, field selectable •Program via FL-PRO411 or FL-PK411UD GET IT NOW! Lite-Connect Module •Consolidates Central Station communications to a single panel •Uses fiber-optic technology •Protection against ground fault and lightning strikes NOW! 6-Zone Fire Alarm Communicator •Can be used as a stand-alone for sprinkler supervisory. Six fully supervised inputs. •Can be used as a slave dialer •Downloadable for remote programming SK-5104 (5104) FL-ANNLC (ANNLC) FL-411UD (411UD) GET IT GET IT NOW! NOW! 117 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Conventional Panels – Addressable Panels/Communication FIRE 4-Zone Digital Alarm Communicator •Four fully supervised input zones •Compact size allows mounting in most local FACPs •Dual phone line interface and line fault monitors •On-board nonsilencing audible alarm SK-5128 (5128) Remote Fire Alarm Annunciator Remote Fire Alarm Annunciator •Compatible with SK-5104, SK-5128, and SK-5129 fire alarm communicators •Can be used as remote annunciator or programmer. 2-line 16-character LCD display. •Compatible with SK-5208 conventional fire alarm control. 2-line 16-character LCD display. •Operation and appearance comparable to the SK-5208 on-board annunciator SK-5235 (SK-5235) SK-5230 (5230) GET IT GET IT NOW! 10-Zone Conventional Control Panel •10 zones expandable to 30 zones •Supervised zone expander can be remotely mounted. Built-in digital communicator. •Four notification appliance circuits SK-5208 (SK-5208) 4-Zone Conventional Control Panel •4 style B (Class B) initiating device circuits •2 style Y (Class B) notification appliance circuits •Form C alarm and trouble relays •24VDC operation SK-SK4 (SK-4) GET IT FL-MS9200UDL (MS9200UDLS) •Integrated DACT for off-premises monitoring •Single SLC provides support for 50 addressable devices •Annunciator bus supports up to 8 devices FL-MS9050UD (MS9050UD) GET IT NOW! Addressable Fire Alarm Panel •Single SLC provides support for 198 addressable devices on twisted, unshielded fire wire •Built-in digital communicator for off-premises monitoring and remote up/download Addressable Fire Alarm Panel GET IT NOW! Addressable Fire Alarm Panel NOW! NOW! CDRM-300 Module •Up to 318 addressable devices/SLC, expandable to 636. Built-in DACT. •Devices operate on standard unshielded “fire” wire. NAC programmable for strobe synchronization. FL-MS9600UDL (MS9600UDLS) •Two monitor inputs with 2 relay outputs into one standard addressable module. Saves the wiring cost. •Saves the cost of three standard junction boxes •HVAC fan and Smoke/fire dampers Applications FL-CDRM300 (CDRM-300) GET IT NOW! GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 118 FIRE Addressable Panels/Communication Addressable Control Module Remote LCD Annunciator •80-character backlit annunciator. Surface or flush-mount. •Available in red or white •Can be remotely located up to 6,000 feet Addressable Control Relay Module •Compatible with Fire-Lite addressable fire control panels. LED Indicator with wall plate. •Switch 24VDC audible/visual power •Mounts in standard 4" junction box FL-CMF300 (CMF300) FL-ANN80 (FL-ANN80) GET IT •Compatible with Fire-Lite addressable fire control panels. LED Indicator with wall plate. •Monitor dual two independent Class B Circuits •Mounts in standard 4" junction box FL-MDF300 (MDF300) FL-CRF300 (CRF300) GET IT NOW! Addressable Dual Monitor Module •Compatible with Fire-Lite addressable fire control panels. Dry-contact output. •LED Indicator with wall plate •Mounts in standard 4" junction box GET IT NOW! Addressable Two-Wire Monitor Module •Compatible with Fire-Lite addressable fire control panels. LED Indicator with wall plate. •Monitor module, two-wire detectors •Mounts in standard 4" junction box NOW! Isolator Module •Compatible with Fire-Lite addressable fire control panels. LED Indicator with wall plate. •Isolate wire-to-wire short circuits •Mounts in standard 4" junction box FL-I300 (I 300) FL-MMF302 (MMF302) GET IT GET IT NOW! Addressable Mini-Monitor Module •Compatible with Fire-Lite addressable fire control panels. LED Indicator with wall plate. •Miniature Monitor Class B Circuit •Mounts in standard 4" junction box FL-MMF301 (MMF301) NOW! IP & GSM Fire Alarm Communicator •Saves phone line charges. Connects to any contact ID fire Panel Communicator via dialer capture. •Uses Alarmnet - Triple Path •NFPA 72,2013 compliant 0H-IPGSM4G (IPGSM-4G) Commercial Fire Communicator •UL864 compliant via single or dual technologies with Internet or GSM communications •Supervision options to meet NFPA72 2010 and 2013 editions •Compatible with Honeywell VISTA control panels •Communication via AlarmNet service IGSMCFP4G (IGSMCFP4G) GET IT NOW! 119 GET IT GET IT NOW! NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Addressable Panels/Communication FIRE Directory Annunciators Custom Graphic Annunciators •Common negative or positive 12 or 24 VDC •Easy to change wording for zone windows. Fits standard gangable electrical box. Rainproof gasket available. LE-DA Series (DA Series) •Provide quick and easy identification along with location of alarm device. High brightness LED syndicate location on custom floor plan display map. •Lamp test standard LE-LD Series (LD Series) PFC-6200 Analog Addressable Fire Panel •127 points expandable to 254 by use of one •SLCE card. 5 Amp power supply. •2 NACs regulated, rated at 3 amps each •2 input/output (I/O) circuits for flexibility rated PL-PFC6200 (PFC-6200) PFC-6800 Analog Addressable Fire Panel SLCE-127 Addressable Loop Expander •127 points expandable to 1,016 by use of 7 SLCE cards •10 Amp power supply. 6 NACs regulated, rated at 3 Amps PL-PFC6800 (PFC-6800) •May mount in panel, accessory cabinet, or PSN-1000/E power supply •No special wiring. Class A or B capable. •Mounts with included stacker bracket PL-SLCE127 (SLCE-127) Addressable Monitor Module •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using System Sensor protocol •Rotary address switches for faster programming SK-MONITOR (SK-MONITOR) GET IT NOW! Addressable Relay Module Addressable Dual Input Module •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using System Sensor protocol •Rotary address switches for fast programming SK-RELAY (SK-RELAY) •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using System Sensor protocol •Monitor two circuits, with unique addresses, simultaneously •Support for Class B wiring fully supervised. Rotary add. Addressable Mini-Monitor Module •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using System Sensor protocol •Compact footprint allows it to fit inside devices SK-MINIMON (SK-MINIMON) SK-MONITOR2 (MONITOR2) GET IT GET IT NOW! NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 120 FIRE Addressable Panels/Communication Addressable Fire Alarm Control Panel •Up to 100 points using SK devices •Built-in digital alarm communicator •Uses standard wire - no shielded or twisted pair required. Up to 50 points using SD devices. SK-5700 (5700) Addressable Fire Alarm Control Panel •Expandable to 792 points using SK Devices •Expandable to 508 points using SD Devices •Uses standard wire - no shielded or twisted pair required. Built-in digital alarm communicator. SK-5820XL (5820XL) GET IT •Up to 127 points using SD devices •Built-in digital alarm communicator •Uses standard wire - no shielded or twisted pair required. Up to 198 points using SK devices. SK-5808 (5808) GET IT NOW! GET IT NOW! IntelliKnightTM Remote Annunciator Red IntelliKnightTM Remote LCD Annunciator - Light Gray •Compatible with Silent Knight IntelliKnightTM addressable fire control panels •80-character backlit LCD display (4x20) •Surface or flush-mount •Compatible with SK-5700, SK-5808, SK-5820XL & SK-5820XLEVS fire alarm control panels. Tactile & audible feedback & SK-5820XLEVS. •80-character backlit LCD display (4 x 20) SK-5860R (5860R) Addressable Fire Alarm Control Panel NOW! Addressable Relay Module •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using Hochiki protocol. Two form C contacts. •Includes LED indicator and wall plate SK-SD500ARM (SD500-ARM) SK-5860 (5860) GET IT GET IT NOW! Signaling Line Circuit Isolator Module •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using Hochiki protocol. Includes LED indicator and wall plate. •Mounts in a standard 4 inch junction box SK-SD500LIM (SD500-LIM) NOW! Addressable Mini-Input Module Addressable Input Module •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using Hochiki protocol •Includes LED indicator and wall plate •Compatible with Silent Knight IntelliKnight addressable fire control panels using Hochiki protocol •Monitors conventional devices switches SK-SD500MIM (SD500-MIM) SK-SD500AIM (SD500-AIM) GET IT GET IT NOW! 121 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us NOW! Get It Now! Addressable Panels/Communication – Commercial Fire/Intrusion Panels FIRE Fiber Converter •Eliminates the risk of lightning damage caused by running copper between buildings •Distributed intelligence allows multiple buildings to be monitored and protected by one FACP •UL 864 listed •Compatible with all IntelliKnight SBUS devices 10 Zone Expander •Compatible with SK-5208 fire alarm control panel •Adds 10 Class B zones to FACP •Mounts inside SK-5208 cabinet or remotely in SK-2190 accessory cabinet. Up to two SK-5217s per system. SK-5217 (5217) TG-7FS Cellular Alarm Communicator for Commercial Fire •Operates on 2G, 3G and 4G networks and CDMA networks. Full data reporting using virtually all alarm formats including Contact ID, Pulse, SIA 2, Modem IIe & lIIa2 & DMP. AD-TG7GFS04 (TG-7FS) GET IT NOW! •AT&T SK-F485C (F485C) AD-TG7VFS04 •Verizon GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 122 FIRE Commercial Fire/Intrusion Panels Combination High Capacity Fire/Burglary Control Panel •128/250 Protection points •Eight on-board (Class B, Style B, including two (2-wire) smoke detector loops •Two-wire addressable expansion (V-Plex-Class B, Style 3) •Wireless expansion •Two on-board NAC circuits •One on-board programmable relay/96 output expansion •Eight partitions •150/250 user codes •512/1000 event log capacity V128FBP-9 GET IT NOW! •VISTA Fire/Burglary Control Panel - 128 Zones VISTA Fire Control Panels ® Our commercial-grade VISTA® Fire control panels provide the ultimate protection of life and property. These robust, cost-effective fire solutions save you money and installation time, readily integrate with access control and leading third party systems, and are compatible with Honeywell’s wireless accessories. •Fire-ready right out of the box •Supports commercial wireless fire devices •Supports Honeywell fire and high security digital cellular communicators •Supports 6160CR-2 Fire Custom Alpha Keypad VISTA Turbo Fire Control Panels •Our advanced VISTA Turbo Fire Control panels provide these additional benefits: •On-Board serial port eliminates the need to purchase a separate 4100SM module •24V Kits available with HPF602ULADA 24 VDC power supply (6A, four synchronized outputs) •Protects battery from deep discharge in instances of prolonged AC power outage (no BSM required) V250FBP-9 •VISTA Fire/Burglary Control Panel - 250 Zones V128FBPT •VISTA Turbo Fire/Burglary Control Panel - 128 Zones V250FBPT •VISTA Turbo Fire/Burglary Control Panel - 250 Zones V128FBPT24KT •VISTA Turbo Fire/Burglary 24V Kit: Includes 128-Zone Control Panel and 24VDC, 6A external power supply (HPF602ULADA) V250FBPT24KT •VISTA Turbo Fire/Burglary 24V Kit: Includes 250-Zone Control Panel and 24VDC, 6A external power supply HPF602ULADA) Entry-Level Combination Fire/Burglary Control Panel •8-32 protection points *Eight on-board (Class B, Style B, including two (2-wire) smoke detector loops *Two-wire addressable expansion (V-Plex-Class B, Style 3) *Wireless expansion •Two on-board NAC circuits •One on-board relay/96 output expansion •Two partitions •75 user codes •512 event log capacity V32FB-9 GET IT •VISTA Fire/Burglary Control - 32 Zones Commercial Fire Custom Alpha Keypad •Large easy-to-read two line Alpha-numeric display •7 status LED’s •Programmable function keys and built in sounder 6160CR-2 NOW! V32FBPT •VISTA Turbo Fire/Burglary Control - 32 Zones V32FBPT-COM •VISTA Turbo Fire/Burglary Control in Industrial Cabinet with External Transformer V32FBPT24KT •VISTA Fire/Burglary kit Includes control panel and 24VDC, 6A external power supply (HPF602ULADA) 123 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! GET IT NOW! Photoelectric System Smoke Detector Comparison Chart Part Number Voltage Range Thermal 2 or 4-Wire Standby Current Alarm Current Aux Relay Direct Wire/ Plug-In Head Functional Test Method NFPA Sensitivity Test Method Comments/ Notes Listings & Approvals ED-FXPD 15.2 to19.95 VDC No 2-Wire 45uA 45uA No Plug-In Smoke Built-in Circuitry 1,2,3 ED-FXPHD 15.2 to19.95 VDC Yes 2-Wire 45uA 45uA No Plug-In Smoke Built-in Circuitry 1,2,3 2 or 4-Wire Standby Current Alarm Current Aux Relay Functional Test Method NFPA Sensitivity Test Method FIRE Edwards/Kidde Gentex Part Number Voltage Range Thermal Direct Wire/ Plug-In Head Comments/ Notes Listings & Approvals GN-9081201 24VDC No 4-Wire 6mA 60mA Yes Direct Wire Test Switch GN-8243P 24VDC No Test Switch Washable 1, 2, 3, 4, 6 4-Wire 6mA 60mA Yes Direct Wire GN-9081203 24VDC Yes 4-Wire 6mA 60mA Yes Direct Wire Test Switch Test Switch Washable 1, 2, 3, 4, 6 Test Switch Test Switch Washable GN-8243PH 24VDC Yes 4-Wire 6mA 60mA Yes 1, 2, 3, 4, 6 Direct Wire Test Switch Test Switch Washable 1, 2, 3, 4, 6 GN-8243PY 24VDC No 4-Wire 6mA 60mA GN-8243PHY 24VDC Yes 4-Wire 6mA 60mA Yes Direct Wire Test Switch Test Switch Washable 1, 2, 3, 4, 6 Yes Direct Wire Test Switch Test Switch Washable 1, 2, 3, 4, 6 Comments/ Notes Listings & Approvals Interlogix/ESL Part Number ES-511C Voltage Range 12/24VDC Thermal No 2 or 4-Wire 2-Wire Standby Current Alarm Aux Current Relay 70uA 60mA No Direct Wire/ Plug-In Head Direct wire Functional Test Method Magnet NFPA Sensitivity Test Method Built-in circuitry 1, 2, 3 ES-521B 6 to 24VDC No 2-Wire 70uA 60mA No Direct Wire Magnet Built-in Circuitry Clean MeTM Alert ES-521BXT 12/24VDC Yes 2-Wire 70uA 60mA No Direct Wire Magnet Built-in Circuitry Clean MeTM Alert 1, 2, 3, 4 ES541NCSXT 12/24VDC Yes 4-Wire 70uA 60mA No Direct Wire Magnet Built-in Circuitry Low Profile 1, 2, 3 ES541NCRXT 12/24VDC Yes 4-Wire 70uA 60mA Yes Direct Wire Magnet Built-in Circuitry Clean MeTM Alert 1, 2, 3 ES541NCSRH 12/24VDC Yes 4-Wire 70uA 60mA Yes Direct Wire Magnet Built-in Circuitry Isolated Heat 1, 2, 3 1, 2, 3, 4 APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 124 FIRE Photoelectric System Smoke Detector Comparison Chart Potter Part Number Voltage Range Thermal 2 or 4-Wire Standby Current Alarm Current Aux Relay Direct Wire/ Plug-In Head Functional Test Method NFPA Sensitivity Test Method Comments/ Notes Listings & Approvals PL-BPS2 12/24VDC No 2-Wire 38uA, 55uA 150mA No Direct Wire None Built-in Circuitry Low Profile 1, 3, 4, 5 PL-BPS2W 12/24VDC No 2-Wire 38uA, 55uA 150mA No Direct Wire None Built-in Circuitry White Housing 1, 3, 4, 5 PL-BPS4 12/24VDC No 4-Wire 38uA, 55uA 150mA No Direct Wire None Built-in Circuitry Low Profile 1, 3, 4, 5 PL-BPS4W 12/24VDC No 4-Wire 38uA, 55uA 150mA No Direct Wire None Built-in Circuitry White Housing 1, 3, 4, 5 Plug-In Magnet Built-in Circuitry Opt.Sounder, 4-wire or relay 1, 2, 3, 4, 5 Plug-In None Built-in Circuitry Opt.Sounder, 4-wire or relay 1, 2, 3, 4, 5 PL-PS24 24VDC No 2-Wire 45uA 150mA Optional Base PL-PS24H 24VDC Yes 2-Wire 45uA 150mA Optional Base Aux Relay System Sensor Part Number Voltage Range 2 or Thermal 4-Wire Standby Current Alarm Current Direct Wire/ Plug-In Head Functional Test Method NFPA Sensitivity Test Method Comments/ Listings & Notes Approvals BK-2WB 12/24VDC No 2-Wire 50uA 130mA Max No Plug-In with Base Included Mechanical Test Button Test w/ Built-in Circuitry Screwdriver Low Profile 1, 3, 4, 5 BK-2WTB 12/24VDC Yes 2-Wire 50uA 130mA Max No Plug-In with Base Included Mechanical Test Button Test w/ Built-in Circuitry Screwdriver Low Profile 1, 3, 4, 5 BK-4WB 12/24VDC No 4-Wire 50uA 23mA No Plug-In with Base Included Mechanical Test Button Test w/ Built-in Circuitry Screwdriver Low Profile 1, 3, 4, 5 BK-4WTB 12/24VDC Yes 4-Wire 50uA 23mA No Plug-In with Base Included Mechanical Test Button Test w/ Built-in Circuitry Screwdriver Low Profile 1, 3, 4, 5 BK-2WTAB 12/24VDC Yes 2-Wire 50uA 130mA Max No Plug-In with Base Included Mechanical Test Button Test w/ Built-in Circuitry Screwdriver Low Profile/ Sounder 1, 3, 4, 5 BK-2WTRB 12/24VDC Yes 2-Wire 50uA 130mA Max Yes Plug-In with Base Included Mechanical Test Button Test w/ Built-in Circuitry Screwdriver Low Profile 1, 3, 4, 5 BK-4WTAB 12/24VDC Yes 4-Wire 50uA 35mA No Plug-In with Base Included Mechanical Test Button Test w/ Built-in Circuitry Screwdriver Low Profile/ Sounder 1, 3, 4, 5 BK-4WTRB 12/24VDC Yes 4-Wire 50uA 35mA Yes Plug-In with Base Included Mechanical Test Button Test w/ Built-in Circuitry Screwdriver Low Profile 1, 3, 4, 5 BK-4WTARB 12/24VDC Yes 4-Wire 50uA 50mA Yes Plug-In with Base Included Mechanical Test Button Test w/ Built-in Circuitry Screwdriver Low Profile/ Sounder 1, 3, 4, 5 BK-4WITARB 12/24VDC Yes 4-Wire 50uA 50mA Yes Plug-In with Base Included Mechanical Test Button Test w/ Built-in Circuitry Screwdriver Low Profile/ Sounder 1, 3, 4, 5 APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago Smoke Detector Testing NFPA 72 requires functional and sensitivity testing on a regular basis. ADI provides products for this requirement. “Tests shall be performed to ensure that each smoke detector is within its listed and marked sensitivity range.” NFPA 72-2007 Chapter 10 (10.4.2.2 13g) “Each detector shall be tested to confirm that it is within its rated operating range.” CAN/ULC-S536-04, 5.7.4.1.3 125 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! FIRE Smoke/CO/Gas Detectors Two-Piece Smoke Detectors •F220 Series Smoke Detectors Direct Wire Photoelectric Smoke Detectors Photoelectric Smoke Alarm •120VAC with 9V battery backup •Silence feature •Latching alarm feature •10 year warranty DS-D263 DS-F220PTHC •Photoelectric, Heat and Carbon Monoxide Smoke Detector DS-F220PTH •Photoelectric Smoke Detector with Heat DS-F220P •Photoelectric Smoke Detector DS-F220B6R •2-wire DS-D263TH •2-wire with heat DS-D273 BR-7010B (7010B) •4-wire DS-D273TH •4-wire with heat •4-wire Base Photo Smoke/ADA Strobe Combo Alarm •120VAC with 2 AAA battery backup (smoke alarm only) •ADA compliant 177 candela strobe •Silence and latching alarm features •10 year limited warranty GET IT NOW! Smoke/CO Combo-Photoelectric Ionization Smoke Alarm •120VAC with 9V battery backup •Silence feature •Latching alarm feature •10 year CO sensor/10 year end of life/10 year warranty •120VAC with 9V battery backup •Silence feature •Latching alarm feature •10 year limited warranty BR-9120B (9120B) BR-SC7010B (SC7010B) BR-7010BSL (7010BSL) GET IT NOW! By INTERLOGIX Smoke/CO Combo with Voice-Photoelectric •120VAC with 9V battery backup •Voice with location •Silence and latching alarm features •10 year CO sensor/10 year end of life/10 year warranty BR-SC7010BV (SC7010BV) Smoke/CO Combo Alarm-Ionization •120VAC with 9V battery backup •Silence feature •Latching alarm feature •10 year CO sensor/10 year end of life/10 year warranty BR-SC9120B (SC9120B) 500 Series Photoelectric 2-Wire Smoke Detectors with CleanMe® •Photoelectric with replaceable optical chamber •CleanMe® signal can call if cleaning is required •Automatic drift compensation •2-wire, P/E, 6 ~ 24VDC ES-521B (521B) GET IT NOW! 126 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Smoke/CO/Gas Detectors TS7 Series Photoelectric Smoke Detector •Head & base design reduces installation & servicing costs. ES-TS74 (TS7-4) ES-TS74T (TS7-4T) •4-wire head & base with heat By INTERLOGIX By INTERLOGIX Power Supervisory Relay Module, 12/24V •Approved for all listed panels •4-wire smoke detectors •Code compliant for fire & life safety use •Fits easily into junction box ES-2041224V (204-12/24V) FIRE By INTERLOGIX Carbon Monoxide Detector with SafeTest™ •SafeTest feature: functional test w/spray of real CO gas. 10-year end-of-life signal. •Advanced electro-chemical sensing technology •Deep housing w/plenty of room for wiring ES-260CO (260-CO) GET IT NOW! By INTERLOGIX 500 Series Photoelectric 2-Wire Smoke Detector with CleanMe® •Fixed temp and rate-of-rise heat •S10A Compatibility. Temporal 3 sounder. •Remote maintenance (CleanMe) reporting and built-in drift compensation •Replaceable optical chamber makes any required cleaning a snap ES-521NCSXT (521NCSXT) By INTERLOGIX 500 Series Photoelectric 4-Wire Smoke Detector with CleanMe® •Fixed temp and rate-of-rise heat •Temporal 3 sounder •Remote maintenance (CleanMe) reporting and built-in drift compensation •Replaceable optical chamber makes any required cleaning a snap ES-541NCSRXT (541NCSRXT) By INTERLOGIX 500 Series Photoelectric 2-Wire Smoke Detector with CleanMe® •Fixed temp and rate-of-rise heat •S11A compatibility •Remote maintenance (CleanMe) reporting and built-in drift compensation •Replaceable optical chamber makes any required cleaning a snap ES-521NCRXT (521NCRXT) By INTERLOGIX 500 Series Photoelectric 4-Wire Smoke Detector with CleanMe® •Fixed temp and rate-of-rise heat •End-of-Line power supv. relay •Remote maintenance (CleanMe) reporting and built-in drift compensation •Replaceable optical chamber makes any required cleaning a snap ES-541NCXTE (541NCXTE) By INTERLOGIX 500 Series Photoelectric 4-Wire Smoke Detector with CleanMe® •Fixed temp and rate-of-rise heat •Auxiliary Relay •Remote maintenance (CleanMe) reporting and built-in drift compensation •Replaceable optical chamber makes any required cleaning a snap By INTERLOGIX 500 Series Photoelectric 4-Wire Smoke Detector with CleanMe® •Fixed temp and rate-of-rise heat •Remote maintenance (CleanMe) reporting and built-in drift compensation •Replaceable optical chamber makes any required cleaning a snap. Temporal 3 sounder. ES-541NCSXT (541NCSXT) ES-541NCRXT (541NCRXT) GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 127 FIRE Smoke/CO/Gas Detectors By INTERLOGIX 500 Series Photoelectric 2-Wire Smoke Detector with CleanMe® •Fixed temp and rate-of-rise heat •Remote maintenance (CleanMe) reporting and built-in drift compensation •Replaceable optical chamber makes any required cleaning a snap. S09A/S10A compatibility. DETECT-A-FIRE®, Detection & Release Devices Wireless Gateway •Reliable, auto-reset, field testable •Rugged; withstands shock and vibration •Versatile; offers various temperature settings •Factory set and the internal contact area is hermetically sealed in stainless steel •Bridges communication from wired to wireless •Integration with Fire-Lite Addressable panels •Class A mesh network •Built-in Tamper feature FL-WGATE (WGATE) FN-12000 Series (12-E27121-000) ES-521BXT (521BXT) GET IT NOW! Wireless Photoelectric Smoke Detector •Wireless installation •Class A mesh network •Frequency hopping •Built-in tamper feature Intelligent Sounder Base Addressable Photo Sensor Smoke Detector with Base •Sounder Base for addressable detectors •Temporal pattern (ANSI Temporal 3) •Continuous tone •Compatible with Fire-Lite addressable fire control panels. Built-in tamper resistant feature. •Two bicolor LEDs – 360° viewing angle •Photo sensor, B210LP base included FL-B200SR (B200SR) FL-WSD355 (WSD355) FL-SD355 (SD355) GET IT GET IT NOW! NOW! Addressable Photoelectric Smoke Detector with Thermal Sensor Addressable Heat Detectors •Compatible with Fire-Lite addressable fire control panels. Built-in tamper resistant feature. •Two bicolor LEDs 360° viewing angle •Photo/Thermal sensor, B210LP base included FL-SD355T (SD355T) •Compatible with Fire-Lite addressable fire control panels. Built-in tamper resistant feature. •Two bicolor LEDs – 360° viewing angle FL-H355 (H355) FL-H355R (H355R) 9000 Series Photoelectric Smoke Alarm •Temporal 3 Evacuation Piezo Sounder •120VAC with 9VDC battery back-up •Options include: Form A/Form C contacts & heat thermals. Temporal 3 Sounder. GN-9123F (9123F) •Rate-of-rise sensor, B210LP base included FL-H355HT (H355HT) •190º high temperature sensor, B210LP base included GET IT NOW! 128 GET IT GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us NOW! Get It Now! Smoke/CO/Gas Detectors FIRE S1209 Series Photoelectric Smoke Alarms Photoelectric Smoke Alarms •120VAC with 9VDC battery back-up •Photoelectric smoke sensor with temporal 3 sounder •Tandem interconnect with other Gentex alarms including smoke/CO and CO alarms •Low or missing battery indicator •120VAC with 9VDC battery back-up •Photoelectric smoke sensor •Low/missing battery indicator GN-GN303 (GN-303) •Temporal 3 Piezo GN-GN300 GN-S1209 (S1209) GN-S1209F (S1209F) •Continuous Piezo Carbon Monoxide (CO) Alarms •120VAC with 9VDC battery back-up. Electrochemical CO sensor. Optional relay model. •Temporal 4 sounder for CO annunciation •Tandem interconnect with other Gentex alarms GN-CO1209 (CO1209) GN-CO1209F (CO1209F) •Form A/Form C relay contacts •Form A/Form C relay contacts Dual Relay Smoke & Carbon Monoxide Alarm Photoelectric System Smoke Detector Combination Smoke & Carbon Monoxide Alarms •120VAC w/9VDC battery back-up •Two sets of Form A/Form C contacts that activate independently for smoke & CO events •Different tones for smoke & CO annunciation GN-GN503FF (GN-503FF) •120VAC w/9VDC back up. Tandem interconnect with other alarms. •Photoelectric smoke sensor & electrochemical CO sensor GN-GN503 (GN503) GN-GN503F (GN-503F) •Available in 24VDC (120VAC models available) •Form A/Form C contacts. On-site washing program. Optional heat thermal. •Optional sounder in temporal 3 GN-9081233 (8100) •Form A/Form C relay contacts GET IT NOW! ADA Compliant Photoelectric Smoke Alarm •120VAC with 9VDC battery back-up •177 Candela ADA compliant strobe & temporal 3 sounder •Ceiling and wall mount versions available GN-7139CSC (7139CS-C) •Form C Contacts GN-7139LS (7139LS) GET IT NOW! Photoelectric System Smoke Detector •Available in 24VDC (120VAC models available) •Form A/Form C relay contacts •Temporal 3 sounder •Non-latching unit (latching unit available) GN-8243PY (8243PY) GN-8243PHY (8243PHY) Supervised Wireless Smoke Detector •Self-Diagnostics reduces the chance of a nuisance alarm •Replaceable optical chamber make cleaning a snap CA-TX6010011 (TX-6010-01-1) •Isolated 135°F Thermal •9 ft. Line Cord Model GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 129 FIRE Smoke/CO/Gas Detectors Versa-Tools Enclosed Delivery Test Head 8 Ft. Aluminum Open Delivery Test Kit •Kit includes: (1) HO-N30 open delivery test head, (1) HO-N59 50" extension pole, (1) HO-1490 smokin gun aerosol adapter, (1) HO-VTB equipment carrying bag •An economy detector tester starter kit for today’s professionals •Used worldwide for over 20 years HO-VTOD (HO-VTOD) Versa-Tools Complete Inspectors Kit The Versa-Tools VT complete kit contains everything a professional needs for the functional testing of smoke, carbon monoxide and heat detector testers. •Kit includes: (1) HO-VTOD open delivery test kit (1) HO-VTED8 8 ft. enclosed delivery test kit (1) HO-VT694 heat detector test kit (1) HO-VP16 16 ft., 4 section fiberglass extension pole (1) HO-VP4X 4 ft. extension pole (1) HO-VTB professional equipment carrying bag •Professional tools at affordable pricing, used by professionals worldwide. •24" enclosed delivery detector test head •Designed for use in areas where airflow must be restricted •Designed to work with the Versa-Tools extension poles •HO-VP8, HO-VP16 and HO-Vp4x •Up to 24 ft. range plus height of man •Designed for use with smoke and carbon monoxide detectors •Economical, uses less aerosol per test HO-VT1 (HO-VT1) Smoke Check, Smoke Detector Tester •UL/ULC Listed, NFPA72 Compliant, manufacturer approved and preferred. 350+ test per can. Safe on sensors, leaves no residue, ozone safe. GWP 3.2, environmentally friendly. HO-25S (HO-25S) PurCheck, Smoke Detector Tester •4.6 oz. PurCheck, the only TOTALLY non-flammable smoke detector test aerosol product •UL/ULC Listed, NFPA72 Compliant, manufacturer approved •Safe on sensors, leaves no residue, 350+ test per can •Does not use 134a or 152a propellants •TOTALLY non-flammable version of 25S Smoke Check HO-30S (HO-30S) HO-VTCOMPLET (HO-VTComplete) Smokin’ Gun Aerosol Adapter •A Versa-Tools product designed for use in open delivery testing •Lightweight, durable, quick, easy and very economical •Directionalizes aerosol, while dissipating the propellant to eliminate residue, moisture and dangerous overspray, backwash and aerosol leaks •Used worldwide since 1994 •UL/ULC Listed, manufacturer approved HO-1490 (HO-1490-1) CoCheck, Carbon Monoxide Detector Tester •.786 oz. CoCheck, 100% all natural product •UL Classified •2800ppm, fastest response time available •Safe on sensors •Preferred by manufacturers and technicians world-wide •GWP .0039, environmentally friendly, ozone safe HO-CO2 (HO-CO rev2) 10 oz. Trigger DustAir •DustAir duster cleaner – trigger actuated •For hand use on all electric & electronic products •Uses 152a & more environmentally friendly air duster product HO-DUS9710 (HO-DUS97-10T) 130 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Smoke/CO/Gas Detectors •Sealed for protection against moisture and impact and ideal for exposed applications like wood windows and doors •Voltage is 12VDC •5mA inactive current 5140DLM FIRE Back-Up Dialer Photo Electric Smoke Detector •Facilitates fire verification for false alarm reduction required by NSI/ SIA-CP-01 standards •Sends alarm, tamper, maintenance and battery condition messages to the system’s receiver •Equipped with dual status indicators •UL268-commercial and residential installation 5806W3 Photo Electric Smoke/Heat Detector Manual Pull Station •Aluminum die cast •Key reset and test; Screw terminals •ADA compliant, UL, CSFM, MEA listed and approved 5140MPS-1 •Ideal for commercial and residential use-UL 268 •Includes built-in fixed temperature thermal detector •Capable of sensing a pre-freeze condition if temperature drops below 41° •Includes long life 3V lithium battery 5808W3 GET IT NOW! V-Plex Addressable Smoke Detector •Low profile design – no disassembly for maintenance •Automatic maintenance reporting •Simple 2 wire installation •Automatic drift compensation 5193SD 5193SDT Wireless Fixed Heat Detector •UL listed for 50 ft. (15.2m) spacing •135 degree Fixed temp alarm 5809FXT Wireless Carbon Monoxide Detector •Now with RealTest® technology allowing for functional testing in the field •Send alarm, trouble, end-of-life, tamper and battery condition to system’s wireless receiver •Generates temporal 4 pattern audible warning in an alarm condition •Easy install on wall or ceiling and long life lithium battery GET IT 5800CO NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 131 FIRE Smoke/CO/Gas Detectors Wireless Carbon Monoxide Alarm •Works with any Interlogix Learn Mode panel •Backwards compatible with discontinued 60-652-95 wireless CO alarm •SafeTest enables functional testing with canned CO •Full compliance and Listed to ANSI/UL2034 standard •Industry-leading 7-year sensor life and 5-year battery life with 3 AA alkaline batteries Ionization Smoke Alarm SafeAir™ Wireless Carbon Monoxide Alarm •SafeTest™ enables functional testing with canned CO •Full compliance and listed to ANSI/UL 2034 Standard 3K-21006378 (21006378) CA-TX6310011 (TX-6310-01-1) GET IT CA-600652095 (600-6520-95) NOW! Carbon Monoxide Alarm Smoke/CO Alarm Relay Modules Photoelectric Smoke Alarm •120VAC with DC battery back-up •Nighthawk CO technology offers 40% longer life •Test button •10 year life •Can be interconnected with other Kidde alarms •120VAC with DC battery back-up •Test/Hush button •Can be interconnected with other Kidde alarms •10 year limited warranty 3K-21006371 (21006371) 3K-21006406 (21006406) •3K-CO120X - CO120X CO alarm relay module •120VAC, 0.08A •Activates on signal from interconnected smoke/ CO alarm •Use to activate auxiliary devices such as bells, sirens, lighting, or system inputs 3K-SM120X (SM-120X) 6-Series Low Voltage Gas Detection •12-24VAC or VDC, 2 Relays, 4-20mA output, buzzer, digital display - CM-6 Carbon Monoxide. (CO), GD-6 Combustibles (EX). Dioxide (NO2), RD-6 Refrigerants (REF), CD-6 Carbon Dioxide. (CO2), OX-6 Oxygen (O2). System Carbon Monoxide Detector System Combustible Gas Detector •EZ-Check® technology allows for functional testing in the field. Trouble relay for circuit trouble and end-of-life notification. 10 year electrochemical sensor. Provides wiring supervision. MA-CME1 (CM-E1) MA-CM6 MA-GD6 •Low voltage detector for combustible/heating gases. Flush or surface mountable enclosure. •Listed for use in residential and light commercial apps. SPDT alarm relay & N.C. trouble/supervisory relays. MA-GD2A (GD-2A) GET IT NOW! 132 •120VAC with DC battery back-up. Test button. •Hush button to temporarily silence nuisance alarms •Can be interconnected with other Kidde alarms GET IT GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us NOW! Get It Now! Smoke/CO/Gas Detectors FIRE S moke Sabre 2.6 oz., Aerosol Smoke Detector Tester •SABRE design eliminates harmful residue & helps prevent improper testing •Faster detector activation and clearing 2S-SABRE (SABRE) Smoke Centurion 2.6 oz., Aerosol Smoke Detector Tester BlowOut Canned Air •Universal- use either handheld or with a dispenser •Silicone free formula reduces risk of detector contamination 2S-M8 (Centurion) 2S-SOLOC6 (SOLOC6) A4 Aerosol Smoke Detector •The only nonflammable smoke on the market •8.5 oz. can yields 500+ tests •Economical aerosol usage. For use with SOLO 330 •UL listed and manufacturer approved 2S-SOLOA4AER (SOLOA4) GET IT •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using Hochiki protocol. Fully supervised. SK-SD5056SB (SK-SD5056SB) Addressable Photoelectric Smoke Detector with 135° F Fixed Thermal •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using System Sensor protocol •Sleek, low-profile design with 6" base SK-PHOTOT (SK-PHOTOT) GET IT NOW! Addressable 6" Detector Sounder Base GET IT NOW! NOW! Tester •Manufacturer Endorsed; only gas approved for System Sensor 1224T CO Detectors & UTC CO Alarms •Suits detectors with speed up test mode 2S-BLOWOUT (BlowOut) GET IT GET IT NOW! C6 Carbon Monoxide Detector Tester •Removes dirt and dust from fire detectors •Helps prevent false alarms; No CFC’s •10 oz can includes directional straw for hard to reach areas NOW! Addressable Photoelectric Smoke Detector Advanced Multi-Criteria Fire/CO Detector •Sends a unique signal to fire alarm control for fire alarm and CO alarm •Compatible with version 13.0 IntelligKnight FACPs programmed for System Sensor protocol •Compatible with Silent Knight IntelliKnight addressable fire control panels using System Sensor protocol. Six inch base included. •Rotary address switches for fast programming SK-PHOTO (SK-PHOTO) SK-FIRECO (SK-FIRECO) GET IT GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us NOW! Get It Now! 133 FIRE Smoke/CO/Gas Detectors Series Smoke Detectors Plug-In Smoke Detectors BK-2151 (2151) •Photo detector head Series Form C Relay Detectors BK-2WTRB (2WTR-B) GET IT NOW! •2-wire with Form C relay, thermal BK-4WTRB (4WTR-B) BK-2151T (2151T) •2- and 4-wire bases available •Requires separate 100 series base •With thermal •4-wire with Form C relay, thermal GET IT NOW! Series Sensitivity Reader Series 2-Wire Detectors •Photoelectric detectors •Dual LED indicators •Drift compensation •Plug-in unit with mounting base included •With or without thermal •For i3 Series detectors •Infrared reader •No voltmeter required •Outputs % per foot & text message •Hand held or connect to pole BK-SENSRDR BK-2WB (2WB) BK-2WTB (2WTB) •With thermal Series 4-Wire Detectors •Photoelectric detectors •Remote maintenance signal •Dual LED indicators •With or without thermal •Drift compensation •Plug-in unit with mounting base included BK-4WB (4W-B) Series Accessories BK-RRSMOD (RRS-MOD) •Synchronizes i3 sounders •Reverses power to i3 Series sounder models BK-A77AB2 (A77AB2) •Retrofit adapter bracket •4-wire BK-4WTB (4WT-B) •With thermal Series Temporal Sounder Detectors BK-2WTAB (2WTA-B) •2-wire with sounder, thermal BK-4WTAB (4WTA-B) •4-wire with sounder, thermal GET IT NOW! BK-4WTARB (4WTAR-B) •4-wire with sounder, thermal, Form C relay BK-4WITARB (BK-4WITAR-B) •4-wire with sounder, isolated thermal, Form C relay 134 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! GET IT NOW! Smoke/CO/Gas Detectors FIRE i4 Series Combination CO/Smoke Detector i4 Series Interface Module •12/24 Volt, system connected, combination carbon monoxide/smoke detector available in a 2-wire or 4-wire version •Sends distinct smoke and CO signals to the panel •Compatible with a wide range of control panels with the use of the required i4 Interface Module •Sounds Temporal 3 for smoke and Temporal 4 for CO •Built-in 85 dB sounder •LEDs display both CO and smoke status •Versatile mounting allows for wall or ceiling placement •Replaceable electrochemical CO cell with 6-year end-of-life timer that signals the panel and chirps to alert the homeowner •RealTest® enables functional test using canned •Easily integrates up to 12 compatible detectors to a wide range of control panels •Sends distinct smoke and CO signals from i4 detectors to the panel •LED indication shows when a detector on the loop requires cleaning or maintenance (2-wire detectors only) •Initiates the EZ Walk loop test (2-wire detectors only) BK-COSMOD2W (COSMOD2W) •2-wire BK-COSMOD4W (COSMOD4W) GET IT NOW! •4-wire BK-COSMO2W (COSMO-2W) •2-wire BK-COSMO4W (COSMO-4W) •4-wire GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 135 FIRE Smoke/CO/Gas Detectors – Heat/Flame/Beam Detectors Addressable Photoelectic Smoke Detector Carbon Monoxide Detector 100 Series Smoke Detector Base •Compatible with Silent Knight IntelliKnight addressable fire alarm control panels using Hochiki protocol •Automatic compensation for sensor contamination. Vandal-resistance locking features. •RealTest® technology allows for functional testing in the field. 6 year electrochemical sensor. •Trouble relay for circuit trouble and end-of-life notification. Provides wiring supervision. •2-wire base for use with 100 Series smoke detectors BK-B110LP (B110LP) BK-CO1224T (CO1224T) SK-SD505PHOT (SD505-PHOTO) GET IT GET IT NOW! NOW! Carbon Monoxide Detector Carbon Monoxide Detector Adaptor •RealTest® technology allows for functional testing in the field •Trouble relay for circuit trouble and end-of-life notification BK-CO1224TR (CO1224TR) FX Series Photoelectric Smoke Detector •Compatible with FireworX Addressable Control Panels •Field replaceable photo chamber •Comprehensive self-diagnostics/environmental compensation •CleanMe/Dirty Detector reporting feature •Cover up marks & footprints of expired CO detectors •“Hook” feature keeps BK-CO1224T steady while installing BK-COPLATE (COPLATE) ED-FXPD (FX-PD) GET IT NOW! FX Series Photo and Fixed Temperature Detector •Photoelectric and 135° F, Fixed-Temp Detector •Compatible with FireworX Addressable Control Panels •Field replaceable photo chamber •Comprehensive self-diagnostics/environmental compensation •CleanMe/Dirty Detector reporting feature ED-FXPHD (FX-PHD) 136 FX Series Detector Base HD135 Fixed Temperature Heat Alarm •Standard detector base for use with ED-FXPD, ED-FXHD, ED-PHD intelligent detectors •Mounts on 2-gang or 4"a sq. elect boxes •Twist and lock installation ED-B4U (B4U) •Available in 120VAC with 9VDC battery back-up •135º F fixed temperature. 90dBA temporal 3 piezo horn •Quick disconnect wiring harness. On site maintenance program. •Tandem interconnect with current Gentex alarms GN-9170023 (HD135) GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Heat/Flame/Beam Detectors •WFD 2" through 8" models •Three year warranty •Three EPS models available •Two sup. switch models T-Tap Waterflow Detectors •For residential applications. 1" NPT connection. •Paddles for 1", 1.25", 1.5", and 2" ferrous and copper sweats, 1" CPVC fee •For residential systems and branch line signaling BK-WFDTN (WFDTN) BK-EPS40EXP (EPS40EXP) BK-WFD40EXP (WFD40EXP) BK-PIBVEXP (PIBEXP) FIRE Explosion Proof Fire Sprinkler Monitoring Devices Beam Smoke Detector Accessories BK-BEAMMMK (BEAMMMK) •Multi-mount kit for BK-BEAM1224(S), allows detector to mount on wall, ceiling & various angles BK-BEAMSMK (BEAMSMK) WFD Series Waterflow Detectors •2" through 8" models. NEMA 4, 450 PSI rated. •Three year warranty. Vane type waterflow switch. •Indoor/outdoor use. Visual switch activation. •Allows for surface mounting of the BK- BEAM1224(S), must be used with BK-BEAMMK BK-BEAMLRK (BEAMLRK) •Long range kit for BK- BEAM1224(S), increases beam detector range up to 328' BK-WFD40N (WFD40N) EPS Series Pressure Switches 5600 Series Mechanical Heat Detectors BK-5601P (5601P) •135° F Fixed/ROR BK-5602 (5602) •194° F Fixed/ROR BK-5603 (5603) BK-EPS402 (EPS402) •135° F Fixed BK-5604 (5604) •194° F Fixed GET IT NOW! Thermal Detector •Electronic heat detection •Variety of mounting bases. Three year warranty. •Provides 135° F fixed temp alarm, point and rate-of-rise thermal sensor BK-5151 (5151) Single-Ended Beam Smoke Detector •Single-ended operation •16' to 328' protection range •4-wire, 12/24VDC operation •BK-BEAM1224S integral sensitivity test feature BK-BEAM1224 (BEAM1224) •For use on dry, pre-action and deluge systems or wet systems with alarm check valve. •Alarm pressure switch and supervisory pressure switch models available. •Three pressure settings – 6 models available. Three year warranty. OSY2 Supervisory Switch •For OS & Y valves. 1-piece adjustable mounting bracket. •3 year warranty. 2 SPDT (Form C) contacts. •Single side entry for conduit. Adjustable actuator. GET IT BK-OSY2 (OSY2) NOW! Control Valve Supervisory Switch •For post indicator & butterfly valves •Three year warranty. Adjustable length actuator. Bi-directional actuator for rising and falling flags. 2 SPDT (Form C) contacts. BK-PIBV2 (PIBV2) Plug-In Type Supervisory Switch •For non-rising stem gate and ball & angle valves. 360° mounting bracket installs easily. •Adjustable length supervisory cord. Cover tamper switch included •Three year warranty BK-PSP1 (PSP1) For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 137 FIRE Heat/Flame/Beam Detectors – Duct Detectors Wireless Rate of Rise and Fixed Temp Heat Detector •Combines both rate of rise and fixed temperature sensors •Trips at 135 degrees F or when temperature rises more that 15 degrees per minute •CSFM for both commercial and residential applications Addressable Fixed Temp Heat Detector •Compatible with Silent Knight IntelliKnight addressable fire control panels using System Sensor protocol •Rotary address switches for fast programming SK-HEAT (SK-HEAT) Addressable Heat Detector •Compatible with Silent Knight IntelliKnight addressable fire alarm control panels using Hochiki protocol •Absolute temperature device •Vandal-resistance locking features SK-SD505HEAT (SD505-HEAT) 5809SS GET IT NOW! Dual-Circuit Heat Detector Flame Sensor •135° F fixed/rate-of-rise, dual-circuit mechanical heat detector BK-5621 (5621) •Ultraviolet rays detection (detected wave length 180~260nm) •High sensitivity with a range of 33'/10m •External output for security panel •Built-in alarm sounder •10V to 30VDC (non-polarity) •Dry contact relay Form C (NO/NC) Addressable Smoke Duct Detector with Relay •Compatible with Silent Knight IntelliKnight addressable fire control panels using Hochiki protocol •Rugged steel backbox with clear plastic cover SK-SD505DCTR (SD505-DUCTR) PU-FS2000E (FS-2000E) GET IT GET IT NOW! NOW! Addressable Photoelectric Duct Smoke Detector •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using Hochiki protocol •Rugged steel backbox with clear plastic cover Addressable Duct Smoke Detector Duct Detector Remote Test Station •Photoelectric smoke detector head included •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using System Sensor protocol •Remote test station is automatic fire detector accessory designed to test duct smoke detectors from a convenient location BK-RTS151 (RTS151) SK-DUCT (SK-DUCT) SK-SD505DUCT (SD505DUCT) GET IT GET IT NOW! 138 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us NOW! Get It Now! Duct Detectors Multi-Signaling Accessory Piezo Annunciator •Audible annunciator of an alarm signal •Provides green power LED and red alarm LED •Intended for use in 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A FIRE Duct Smoke Detectors, Relays and Accessories •Multi-function accessory. Provides LED detector status. •Audible & visible notification •AOS (Add on Strobe) option. Remote test cable. •Compatible to InnovairFlex 4-wire duct smoke detectors BK-RTS2AOS (RTS2-AOS) •Add on strobe (AOS) BK-RTS2 (RTS2) BK-APA151 (APA151) Multi-Voltage Relays Innovair Flex Duct Smoke Detector •Flexible Housing Footprint – square, rectangular, or anything in between •Plug-in sensor offers ease of maintenance and latest sensor technology •Broad Operating Temperature Range - 4° F to 158° F and broad humidity range (0% to 95% non-condensing) BK-D2 (D2) •End of line epoxy encapsulated SPDT relay •Easy & flexible installation •High current switching applications, such as fan & damper assembly control, door control, air handing unit controls, and more GET IT NOW! •Reliable & robust design BK-PR3 (PR3) •2-wire conventional •Epoxy encapsulated SPDT relays with an activation LED BK-D4120 (D4120) •4-wire conventional Innovair Flex Watertight Duct Smoke Detector •4-wire photo with aux relay. Lowflow technology and NEMA4 rating. •Eliminates need for costly separate enclosures. Airflow speeds of 100 to 400 per minute. •Broad temperature range - 4° F to 158° F. Broad humidity of 0% to 95% non-condensing. •UV-resistant, UL listed housing and cover materials GET IT BK-D4120W (D4120W) BK-PR1 (PR1) BK-EOLR1 (EOLR1) NOW! Multi-Voltage Relays BK-R10T (R-10T) BK-R20T (R-20T) •Single track mount relays, SPDT/DPDT BK-R14T (R-14T) BK-R24T (R-24T) •4-gang track mount relays, SPDT/DPDT BK-R10E (R-10E) BK-R20E (R-20E) •Single steel enclosure relays, SPDT/DPDT BK-R14E (R-14E) BK-R24E (R-24E) •4-gang steel enclosure relays, SPDT/DPDT For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 139 FIRE Duct Detectors – Alarm Stations Duct Sampling Tube Remote Test Station with Key •Key activated test & rest functions •Installs into a single-gang electrical box •Multi-colored LED indicates power (green) and alarm (red) BK-RTS151KEY (RTS151KEY) Duct Sampling Tube •Metal sampling tube •Metal sampling tube BK-DST3 (DST3) BK-DST10 (DST10) •Duct widths 2 ft. to 4 ft. (0.6 to 1.2 m) •Duct widths 8 ft. to 12 ft. (2.4 to 3.7 m) BK-DST5 (DST5) BK-DST15 (DST15) •Duct widths 4 ft. to 8 ft. (1.2 to 2.4 m) •Duct widths 1 ft. to 2 ft. (0.3 to 0.6 m) GET IT GET IT GET IT NOW! NOW! NOW! Image Not Shown 4-Wire Photoelectric No-Flow/Low-Flow Smoke Detector •Replaceable sensor for D4120 & D4120W •For pendant mount applications with 8210LP base and DUP120 power board •Remote test capable BK-2D51 (2D51) Fire Alarm Pull Station FL-BG12 (BG-12) GET IT NOW! NOW! Manual Pull Station •Dual & single action with hex or key lock models •Non-coded manual pull stations •Meets ADA 5 lb. max pull force •Provides manual alarm initiating input signal FL-BG8 (BG8) GET IT NOW! Manual Pull Station •Aluminum die-formed •Wire leads, SPST •Single action, key reset •ADA compliant ED-270GLR (270-GLR) GET IT GET IT Pull Station •Replacement rods for Edwards Pull Station •Package of 20 ED-270ASPO (270A-SPO) NOW! 140 Replacement Glass Rods •Simple positive operation •Break glass. Attractive, streamline design. •Less than 5 lb. pull force complies with ADA •Solid, die-cast metal construction •Pull station dual with key lock •Non-coded manual pull stations •Meets ADA 5 lb. max pull force •Provides manual alarm initiating input signal FL-BG12L (BG-12L) GET IT GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us NOW! Get It Now! Alarm Stations FIRE Dual Pull Station with Key and Back Box Outdoor Pull Station •Listed for outdoor applications •Dual action operation with key lock Addressable Pull Station •Includes outdoor listed backbox, and sealing gasket •Dual & single action with hex or key lock models •Provides manual alarm initiating input signal FL-BG12LO (BG-12LO) FL-BG12LOB (BG12LOB) GET IT •Compatible with Silent Knight IntelliKnightTM addressable fire alarm control panel using Hochiki protocol •Surface mount back box available GET IT NOW! NOW! Addressable Single Action Pull Station •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using System Sensor protocol SK-PULLSA (SK-PULL-SA) SK-SD500PS (SD500-PS) Conventional Single Action Pull Station •Single Action with key lock reset •Meets ADA 5 lb. max pull force •Reset with same key as Silent Knight panel enclosure SK-PSSA (PS-SA) GET IT GET IT NOW! NOW! Addressable Dual Action Pull Station Addressable Dual Action Pull Station •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using Hochiki protocol •Surface mount back box available SK-SD500PSDA (SD500-PSDA) FL-BG12LX (BG12LX) GET IT NOW! Addressable Single Action Pull Station •Addressable manual pull station •Capture screw terminals wire-ready •Use with Fire-Lite addressable FACP’s •Dual action operation •Compatible with Silent Knight IntelliKnightTM addressable fire control panels using System Sensor protocol •LED indicator visible through pull station handle SK-PULLDA (SK-PULL-DA) GET IT NOW! Conventional Dual Action Pull Station •Dual action with key lock reset •Resets with same key as Silent Knight panel enclosure •Meets ADA 5 lb. max pull force SK-PSDA (PS-DA) GET IT GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us NOW! Get It Now! 141 FIRE Alarm Stations RELAY RELAY •24VDC, 24/120/230VAC, 10A, SPDT Polarized code compliant RELAY •12/24VDC, 7A, SPDT Polarized code compliant O6-PAM2 (SSU-PAM-2) O6-MR101CR (SSU-MR-101/C/R) •24VDC, 24/120VAC, 10A, Polarized code compliant O6-PAM1 (SSU-PAM-1) GET IT NOW! GET IT GET IT NOW! NOW! RELAY •24VDC/24/120/230VAC 10A DPDT Polarized code compliant O6-MR201CR (SSU-MR-201/C/R) GET IT NOW! 142 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Notification Appliance Comparison Chart Vendor Model Number Part Number Operating Voltage Strobe Candella Unit Type FSEX-24PMR-150 FD-FSEX24PMR150 24VDC Explosion Proof Strobe 150 LSEX-24CMC FD-LSEX24CMC 24VDC Explosion Proof Strobe LSEX-24WMC FD-LSEX24WMC 24VDC LSEX-24CMR FD-LSEX24CMR LSEX-24WMR DBA Rating Current Draw Mounting Options Box Type Approvals Listing 1.9A Pendant, Ceiling Wall 1, 3 15 500mA Wall Ceiling 1, 3 Explosion Proof Strobe 15 500mA Wall Ceiling 1, 3 24VDC Explosion Proof Strobe 15 500mA Wall Ceiling 1, 3 FD-LSEX24WMR 24VDC Explosion Proof Strobe 15 500mA Wall Ceiling 1, 3 FHEX-24SMR FD-FHEX24SMR 24VDC Explosion Proof Strobe 94dB 1.2A Wall ASHP-24SMR FD-ASHP24SMR 24VDC, 25 or Amplified 70Vrms speaker 97dB 225mA Wall 1, 3, 4 ASHP-ACSMR FD-ASHPACSMR 120AC Amplified speaker 97dB 225mA Wall 1, 3, 4 ASHH-24SMR FD-ASHH24SMR 24VDC, 25 or Amplified 70Vrms speaker 97dB 225mA Wall 1, 3, 4 ASHX-24SMR FD-ASHX24SMR 24VDC, 25 or Amplified 70Vrms speaker 93dB 225mA Wall 1, 3, 4 SPHP-DVSMR FD-SPHPDVSMR output 25 or 70Vrms High speaker 0.5, 1, 2, 7 and 15 Watts NA Wall 1, 3, 4 SPHH-DVSMR FD-SPHHDVSMR output 25 or 70Vrms High speaker 0.5, 1, 2, 7 and 15 Watts NA Wall 1, 3, 4 SPHX-DVSMR FD-SPHXDVSMR output 25 or 70Vrms High speaker 0.5, 1, 2, 7 and 15 Watts NA Wall 1, 3, 4 107 EAB exp. condit box FIRE Commercial Product Group 1, 3 Eaton (Cooper Wheelock) Vendor Model Number RSSWP-2475WFR Part Number Operating Voltage Strobe Candella Unit Type DBA Rating Current Draw Mounting Options Box Type Approvals Listing WH-129013 24VDC Strobe 30 (115) N/A 0.138 Wall WPSBB - WFP 1, 2, 3, 4, 5 MTWP-2475W-FR WH-128420 24VDC Multitone/ Strobe 30 (115) 87-99 .162 - .248 Wall IOBR - WFP 1, 2, 3, 4, 5 ASWP-2475W-FR WH-129012 24VDC Horn/Strobe 30 (115) 90, 95, 99 .150 - .168 Wall WBB - WFPA 1, 2, 3, 4, 5, 6 MIZ-24S-R WH-138485 24VDC Horn N/A 87 0.026 Wall/Ceiling 4" Sq. (S/F) 1, 2, 3, 4, 5 E50-24MCW-FR WH-110226 24VDC Speaker/ Strobe 15/30/75/110 77-88 (Revert) .161 - .220 Wall 4" Sq. (S/F) 1, 3, 5 E50-24MCWH-FR WH-110228 24VDC Speaker/ Strobe 135/185 77-88 (Revert) .300 - .420 Wall 4" Sq. (S/F) 1, 3, 5 E60-24MCC-FW WH-113747 24VDC Speaker/ Strobe 15/30/75/95 77-88 (Revert) .065 - .249 Ceiling 4" or 5" Sq. 1, 3, 5 E60-24MCCH-FW WH-113749 24VDC Speaker/ Strobe 115/177 77-88 (Revert) .300 - .420 Ceiling 4" or 5" Sq. 1, 3, 5 ET70WP-2475WFR WH-119077 24VDC Speaker/ Strobe 30 (115) 77-93 (Revert) 0.138 Wall IOBR - WFP 1, 3, 4 HSR WH-HSRW 12/24VDC Horn/Strobe 15/1575/30/75/ 90,95,99 DB 95/110/135/185 Universal Mounting Base 1, 2, 3, 4, 5 0.0650.384 VDC Depen- Wall dent APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 143 FIRE Notification Appliance Comparison Chart Eaton (Cooper Wheelock) (Cont’d) Vendor Model Number Part Number Operating Voltage Strobe Candella Unit Type DBA Rating Current Draw Mounting Options Box Type Approvals Listing HSW WH-HSW 12/24VDC Horn/Strobe 15/1575/30/75/ 90,95,99 DB 95/110/135/185 0.0650.384 VDC Depen- Wall dent Universal Mounting Base 1, 2, 3, 4, 5 HSRC WH-HSRC 12/24VDC Horn/Strobe 15/30/60/75/ 95/115/150/177 90,95,99 DB 0.0650.378 VDC Depen- Ceiling dent Universal Mounting Base 1, 2, 3, 4, 5 HSWC WH-HSWC 12/24VDC Horn/Strobe 15/30/60/75/ 95/115/150/177 90,95,99 DB 0.0650.378 VDC Depen- Ceiling dent Universal Mounting Base 1, 2, 3, 4, 5 STR WH-STR 12/24VDC Strobe 15/1575/30/75/ N/A 95/110/135/185 0.0570.372 VDC Depen- Wall dent Universal Mounting Base 1, 2, 3, 4, 5 STW WH-STW 12/24VDC Strobe 15/1575/30/75/ N/A 95/110/135/185 0.0570.372 VDC Depen- Wall dent Universal Mounting Base 1, 2, 3, 4, 5 STRC WH-STRC 12/24VDC Strobe 15/30/60/75/ 95/115/150/177 N/A 0.0570.253 VDC Depen- Ceiling dent Universal Mounting Base 1, 2, 3, 4, 5 STWC WH-STWC 12/24VDC Strobe 15/30/60/75/ 95/115/150/177 N/A 0.0570.253 VDC Depen- Ceiling dent Universal Mounting Base 1, 2, 3, 4, 5 HNR WH-HNR 12/24VDC Horn N/A 90,95,99 DB 0.0170.086 DB & VDC Dep. Wall Universal Mounting Base 1, 2, 3, 4, 5 HNW WH-HNW 12/24VDC Horn N/A 90,95,99 DB 0.0170.086 DB & VDC Dep. Wall Universal Mounting Base 1, 2, 3, 4, 5 HNRC WH-HNRC 12/24VDC Horn N/A 90,95,99 DB 0.0170.086 DB & VDC Dep. Ceiling Universal Mounting Base 1, 2, 3, 4, 5 HNWC WH-HNWC 12/24VDC Horn N/A 90,95,99 DB 0.0170.086 DB & VDC Dep. Ceiling Universal Mounting Base 1, 2, 3, 4, 5 LHSR WH-LHSR 24VDC Horn Strobe 15/30/75/110 90, 95 .039 - .258 Wall Single Gang, 4" Sq, Double Gang 1, 2, 3 LSTR WH-LSTR 24VDC Strobe 15/30/75/110 N/A .032 - .246 Wall Single Gang, 4" Sq, Double Gang 1, 2, 3 LHNR WH-LSHNR 24VDC Horn N/A 90, 95 .025 - .028 Wall Single Gang, 4" Sq, Double Gang 1, 2, 3 APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago 144 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Notification Appliance Comparison Chart Vendor Model Number Part Number Operating Voltage Unit Type Strobe Candella 116DEGEX-FJ ED-116DEGXFJ 24VDC/FWR Explosion Proof Strobe 60 wall; 125 ceiling 2447TH-R ED-2447THR 24VDC/FWR Horn 2447TH-W ED-2447THW 24VDC/FWR Horn 2452THS-110-R ED-2452THS11 24VDC/FWR Horn/Strobe 2452THS15/75-R ED-2452T157R 24VDC/FWR Horn/Strobe 438D-10N5 ED-438D10N5 24VDC 438D-10N5-R ED-438D10N5R 438D-6N5 DBA Rating Current Draw Mounting Options Box Type Approvals Listing 0.505 dc; 0.683 fwr Wall/ Ceiling/ Pendant 85 0.040 dc; 0.055 fwr Wall/Ceiling W.P. - Outdoor; 1, 2, 3, 4" sq x 2.5" 4, 5 indoor 85 0.040 dc; 0.055 fwr Wall/Ceiling W.P. - Outdoor; 1, 2, 3, 4" sq x 2.5" 4, 5 indoor 110 85 0.392 dc; 0.420 fwr Wall/Ceiling W.P. - Outdoor; 1, 2, 3, 4" sq x 2.5" 4, 5 indoor 15/75 85 0.150 dc; 0.210 fwr Wall/Ceiling W.P. - Outdoor; 1, 2, 3, 4" sq x 2.5" 4, 5 indoor Bell 88 0.034 Wall Single gang, 3" octogon, 4" 1, 3, 4, 5 square 120VAC Bell 88 0.034 Wall Single gang, 3" octogon, 4" 1, 3, 4, 5 square ED-438D6N5 120VAC Bell 85 0.034 Wall Single gang, 3" octogon, 4" 1, 3, 4, 5 square 438D-6N5-R ED-438D6N5R 120VAC Bell 85 0.034 Wall Single gang, 3" octogon, 4" 1, 3, 4, 5 square 438D-8N5 ED-438D8N5 120VAC Bell 85 0.034 Wall Single gang, 3" octogon, 4" 1, 3, 4, 5 square 438D-8N5-R ED-438D8N5R 120VAC Bell 85 0.034 Wall Single gang, 3" octogon, 4" 1, 3, 4, 5 square 439D-10AW ED-439D10AW 24VDC Bell 85 0.085 Wall Single gang, 3" octogon, 4" 1, 3, 4, 5 square 439D-10AW-R ED-439D10AWR 24VDC Bell 85 0.085 Wall Single gang, 3" octogon, 4" 1, 3, 4, 5 square 439D-6AW ED-439D6AW 24VDC Bell 82 0.085 Wall Single gang, 3" octogon, 4" 1, 3, 4, 5 square 439D-6AW-R ED-439D6AWR 24VDC Bell 82 0.085 Wall Single gang, 3" octogon, 4" 1, 3, 4, 5 square 439D-8AW ED-439D8AW 24VDC Bell 82 0.085 Wall Single gang, 3" octogon, 4" 1, 3, 4, 5 square 439D-8AW-R ED-439D8AWR 24VDC Bell 82 0.085 Wall Single gang, 3" octogon, 4" 1, 3, 4, 5 square 439DEX-10AW ED-439DX10AW 24VDC Explosion Proof Bell 89 0.24 Wall Included 1, 2, 3 FIRE Edwards Signaling 1, 3 APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 145 FIRE Notification Appliance Comparison Chart Edwards Signaling (Cont’d) Vendor Model Number Part Number Operating Voltage Strobe Candella Unit Type DBA Rating Current Draw Mounting Options Box Type Approvals Listing 439DEX-6AW ED-439DEX6AW 24VDC Explosion Proof Bell 86 0.24 Wall Included 1, 3 439DEX-8AW ED-439DEX8AW 24VDC Explosion Proof Bell 83 0.24 Wall Included 1, 3 5530MD-24AW ED-5530MD24A 24VDC/FWR Haz-Loc Multi-tone 110 .63 - 1.0 Wall Included 1, 2 888D-N5 ED-888DN5 120VAC Explosion Proof Horn 90 0.165 Wall Included 1, 3 889D-AW ED-889DAW 24VDC Explosion Proof Horn 84 0.16 Wall Included 1, 3 5530MD-24AW ED-5530MD24A 24VDC/FWR Haz-Loc Multi-tone 110 .63 - 1.0 Wall Included 1, 2 888D-N5 ED-888DN5 120VAC Explosion Proof Horn 90 0.165 Wall Included 1, 3 889D-AW ED-889DAW 24VDC Explosion Proof Horn 84 0.16 Wall Included 1, 3 CS405-7A-T ED-CS4057AT 24VDC/FWR Strobe 15 .150 dc; .392 fwr Wall W.P - Outdoor 1, 2, 3, 4, 5 CS405-8A-T ED-CS4058AT 24VDC/FWR Strobe 110 .21 dc; .42 fwr Wall W.P. - Outdoor 1, 2, 3, 4, 5 EG1-C ED-EG1C 24VDC/FWR Chime 61 .032 dc; .065 fwr Wall Single gang or 4" sq. w/ trim 1, 3, 4 EG1-CVM ED-EG1CVM 24VDC/FWR 30, 75, Chime/Strobe 15, 110 61 .099- .227 dc; .154- .383 fwr Wall Single gang or 4" sq. w/ trim 1, 3, 4 EG1F-C ED-EG1FC 24VDC/FWR Chime 61 .032 dc; .065 fwr Wall Single gang or 4" sq. w/ trim 1, 3, 4 EG1F-CVM ED-EG1FCVM 24VDC/FWR 30, 75, Chime/Strobe 15, 110 61 .099- .227 dc; .154- .383 fwr Wall Single gang or 4" sq. w/ trim 1, 3, 4 EG1F-HD ED-EG1FHD 24VDC/FWR Horn 89 .026 dc; .051 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 EG1F-HDVM ED-EG1FHDVM 24VDC/FWR Horn/Strobe 89 .129- .337 dc; .176- .443 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 EG1F-P ED-EG1FP 24VDC/FWR Horn 77 .013 dc; .011 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 EG1F-VM ED-EG1FVM 24VDC/FWR Strobe .103- .311 dc; .125- .392 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 EG1-HD ED-EG1HD 24VDC/FWR Horn 89 .026 dc; .051 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 EG1-HDVM ED-EG1HDVM 24VDC/FWR Horn/Strobe 89 .129- .337 dc; .176- .443 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 EG1-P ED-EG1P 24VDC/FWR Horn 77 .013 dc; .011 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 EG1R-C ED-EG1RC 24VDC/FWR Chime 61 .032 dc; .065 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 EG1R-CVM ED-EG1RCVM 24VDC/FWR 30, 75, Chime/Strobe 15, 110 61 .099- .227 dc; .154- .383 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 EG1RF-CVM ED-EG1RFCVM 24VDC/FWR 30, 75, Chime/Strobe 15, 110 61 .099- .227 dc; .154- .383 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 15, 30, 75, 110 15, 30, 75, 110 15, 30, 75, 110 APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago 146 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Notification Appliance Comparison Chart Vendor Model Number Part Number Operating Voltage Unit Type Strobe Candella DBA Rating Current Draw Mounting Options Box Type Approvals Listing 89 .026 dc; .051 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 89 .129- .337 dc; .176- .443 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 77 .013 dc; .011 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 .103- .311 dc; .125- .392 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 89 .026 dc; .051 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 89 .129- .337 dc; .176- .443 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 77 .013 dc; .011 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 15, 30, 75, 110 .103- .311 dc; .125- .392 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 Strobe 15, 30, 75, 110 .103- .311 dc; .125- .392 fwr Wall Single gang or 4" sq. w/ trim 1, 2, 3, 4 24VDC/FWR; 25Vrms Speaker/ Strobe 15, 30, 75, 110 .096- .294 dc; .120- .375 fwr Wall 4" sq x 2-1/8 1, 2, 3, 4 ED-EG4FS7 70Vrms Speaker EG4F-S7VM ED-EG4FS7VM 24VDC/ FWR; Speaker/ 70Vrms Strobe EG4RF-S2VM ED-EG4RFS2VM 24VDC/FWR; 25Vrms Speaker/ Strobe EG4RF-S7 ED-EG4RFS7 Speaker EG4RF-S7VM FWR; Speaker/ ED-EG4RFS7VM 24VDC/ 70Vrms Strobe EG4R-S2 ED-EG4RS2 25Vrms Speaker EG4R-S2VM ED-EG4RS2VM 24VDC/FWR; 25Vrms Speaker/ Strobe EG4R-S7 ED-EG4RS7 70Vrms Speaker EG4R-S7VM ED-EG4RS7VM 24VDC/ FWR; Speaker/ 70Vrms Strobe EG4-S2 ED-EG4S2 25Vrms EG4-S2VM ED-EG4S2VM 24VDC/ FWR; Speaker/ 25Vrms Strobe EGCF-S2VMH ED-EGCFS2VMH 24VDC/FWR; 25Vrms Speaker/ Strobe EGCF-S7 ED-EGCFS7 70Vrms Speaker 80, 84, 87, 91 EGCF-S7VM ED-EGCFS7VM 24VDC/ FWR; Speaker/ 70Vrms Strobe 15, 30, 75, 95 80, 84, 87, 91 EGCF-S7VMH FWR; Speaker/ ED-EGCFS7VMH 24VDC/ 70Vrms Strobe 95, 115, 150, 177 EGCF-VM ED-EGCFVM 24VDC/FWR Strobe EGCF-VMH ED-EGCFVMH 24VDC/FWR EGC-HDVM ED-EGCHDVM EGC-HDVMH ED-EGCHDVMH EG1RF-HD ED-EG1RFHD EG1RF-HDVM ED-EG1RFHDVM 24VDC/FWR Horn/Strobe EG1RF-P ED-EG1RFP 24VDC/FWR Horn EG1RF-VM ED-EG1RFVM 24VDC/FWR Strobe EG1R-HD ED-EG1RHD 24VDC/FWR Horn EG1R-HDVM ED-EG1RHDVM 24VDC/FWR Horn/Strobe EG1R-P ED-EG1RP 24VDC/FWR Horn EG1R-VM ED-EG1RVM 24VDC/FWR Strobe EG1-VM ED-EG1VM 24VDC/FWR EG4F-S2VM ED-EG4FS2VM EG4F-S7 24VDC/FWR 70Vrms Horn 15, 30, 75, 110 15, 30, 75, 110 15, 30, 75, 110 80, 83, 86, 89 80, 83, 86, 89 15, 30, 75, 110 15, 30, 75, 110 Wall 4" sq x 2-1/8 1, 2, 3, 4 80, 83, 86, 89 .096- .294 dc; .120- .375 fwr Wall 4" sq x 2-1/8 1, 2, 3, 4 80, 83, 86, 89 .096- .294 dc; .120- .375 fwr Wall 4" sq x 2-1/8 1, 2, 3, 4 Wall 4" sq x 2-1/8 1, 2, 3, 4 Wall 4" sq x 2-1/8 1, 2, 3, 4 Wall 4" sq x 2-1/8 1, 2, 3, 4 Wall 4" sq x 2-1/8 1, 2, 3, 4 Wall 4" sq x 2-1/8 1, 2, 3, 4 Wall 4" sq x 2-1/8 1, 2, 3, 4 80, 83, 86, 89 15, 30, 75, 110 80, 83, 86, 89 .096- .294 dc; .120- .375 fwr 80, 83, 86, 89 15, 30, 75, 110 80, 83, 86, 89 .096- .294 dc; .120- .375 fwr 80, 83, 86, 89 15, 30, 75, 110 Speaker 80, 83, 86, 89 .096- .294 dc; .120- .375 fwr 80, 83, 86, 89 Wall 4" sq x 2-1/8 1, 2, 3, 4 80, 83, 86, 89 .096- .294 dc; .120- .375 fwr Wall 4" sq x 2-1/8 1, 2, 3, 4 80, 84, 87, 91 .330- .565 dc; .432- .693 fwr Ceiling or Wall 4" sq x 2-1/8 1, 2, 3 Ceiling or Wall 4" sq x 2-1/8 1, 2, 3 .109- .318 dc; .131- .437 fwr Ceiling or Wall 4" sq x 2-1/8 1, 2, 3 .330- .565 dc; .432- .693 fwr Ceiling or Wall 4" sq x 2-1/8 1, 2, 3 15, 30, 75, 95 .109- .318 dc; .131- .437 fwr Ceiling or Wall 4" sq x 2-1/8 1, 2, 3, 4 Strobe 95, 115, 150, 177 .330- .565 dc; .432- .693 fwr Ceiling or Wall 4" sq x 2-1/8 1, 2, 3, 4 24VDC/FWR Horn/Strobe 15, 30, 75, 95 .147- .372 dc; .189- .451 fwr Ceiling or Wall 4" sq x 2-1/8 1, 2, 3, 4 24VDC/FWR Horn/Strobe 95, 115, 150, 177 .341- .570 dc; .487- .711 fwr Ceiling or Wall 4" sq x 2-1/8 1, 2, 3, 4 15, 30, 75, 110 95, 115, 150, 177 80, 84, 87, 91 FIRE Edwards Signaling (Cont’d) APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 147 FIRE Notification Appliance Comparison Chart Edwards Signaling (Cont’d) Vendor Model Number Part Number Operating Voltage Unit Type Strobe Candella DBA Rating Current Draw Mounting Options Box Type Approvals Listing Ceiling or Wall 4" sq x 2-1/8 1, 2, 3 Ceiling or Wall 4" sq x 2-1/8 1, 2, 3 Ceiling or Wall 4" sq x 2-1/8 1, 2, 3 .109- .318 dc; .131- .437 fwr Ceiling or Wall 4" sq x 2-1/8 1, 2, 3 .330- .565 dc; .432- .693 fwr Ceiling or Wall 4" sq x 2-1/8 1, 2, 3 15, 30, 75, 95 .109- .318 dc; .131- .437 fwr Ceiling or Wall 4" sq x 2-1/8 1, 2, 3, 4 95, 115, 150, 177 .330- .565 dc; .432- .693 fwr Ceiling or Wall 4" sq x 2-1/8 1, 2, 3, 4 .069 dc; .135fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1, 2, 3 15, 29, 70, 87 95 .127- .351 dc; .218- .422 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1, 2, 3 102, 123, 147, 95 161 .342- .526 dc; .447- .679 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1, 2, 3 Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 .106- .319 dc; .120-.376 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 .324- .495 dc; .412- .646 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 .069 dc; .135fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1, 2, 3 15, 29, 70, 87 95 .127- .351 dc; .218- .422 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1, 2, 3 102, 123, 147, 95 161 .342- .526 dc; .447- .679 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1, 2, 3 Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 .106- .319 dc; .120-.376 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 .324- .495 dc; .412- .646 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 EGC-S2 ED-EGCS2 25Vrms Speaker 80, 84, 87, 91 EGC-S2VM ED-EGCS2VM 24VDC/FWR; 25Vrms Speaker/ Strobe 15, 30, 75, 95 80, 84, 87, 91 EGC-S7 ED-EGCS7 70Vrms Speaker 80, 84, 87, 91 EGC-S7VM ED-EGCS7VM 24VDC/ FWR; Speaker/ 70Vrms Strobe 15, 30, 75, 95 80, 84, 87, 91 EGC-S7VMH ED-EGCS7VMH 24VDC/ FWR; Speaker/ 70Vrms Strobe 95, 115, 150, 177 EGC-VM ED-EGCVM 24VDC/FWR Strobe EGC-VMH ED-EGCVMH 24VDC/FWR Strobe WG4RF-H ED-WGRFH 24VDC/FWR Horn WG4RF-HVMC ED-WGRFHVMC 24VDC/FWR Horn/Strobe WG4RF-HVMHC ED-WGRFHVMHC 24VDC/FWR Horn/Strobe WG4RF-S ED-WGRFS 25 or 70Vrms Speaker 81, 84, 87, 90 WG4RF-SVMC ED-WGRFSVMC 24VDC/FWR; Speaker/ 25 or 70Vrms Strobe 15, 29, 70, 87 81, 84, 87, 90 WG4RF-SVMHC ED-WGRFSVMH 24VDC/FWR; Speaker/ 25 or 70Vrms Strobe 102, 123, 147, 81, 84, 87, 90 161 WG4RN-H ED-WGRNH 24VDC/FWR Horn WG4RN-HVMC ED-WGRNHVMC 24VDC/FWR Horn/Strobe WG4RN-HVMHC ED-WGRNHVMHC 24VDC/FWR Horn/Strobe WG4RN-S ED-WGRNS 25 or 70Vrms Speaker 81, 84, 87, 90 WG4RN-SVMC ED-WGRNSVMC 24VDC/FWR; Speaker/ 25 or 70Vrms Strobe 15, 29, 70, 87 81, 84, 87, 90 WG4RN-SVMHC ED-WGRNSVMHC 24VDC/FWR; Speaker/ 25 or 70Vrms Strobe 102, 123, 147, 81, 84, 87, 90 161 WG4WA-S ED-WGWAS 25 or 70Vrms Speaker 81, 84, 87, 90 80, 84, 87, 91 95 95 .109- .318 dc; .131- .437 fwr APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago 148 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Notification Appliance Comparison Chart Vendor Model Number Part Number Operating Voltage Unit Type Strobe Candella DBA Rating Current Draw Mounting Options Box Type Approvals Listing WG4WA-SVMA Speaker/ ED-WGWASVMA 24VDC/FWR; 25 or 70Vrms Strobe, Amber 13, 25, 59, 62 81, 84, 87, 90 .106- .319 dc; .120-.376 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 WG4WA-SVMC Speaker/ ED-WGWASVMC 24VDC/FWR; 25 or 70Vrms Strobe .106- .319 dc; .120-.376 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 81, 84, 87, 90 .324- .495 dc; .412- .646 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 102, 123, 147, 81, 84, 87, 90 161 .324- .495 dc; .412- .646 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 .069 dc; .135fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1, 2, 3 15, 29, 70, 87 81, 84, 87, 90 WG4WA-SVMHA ED-WGWASVMHA 24VDC/FWR; Speaker/ 84, 101, 125, 25 or 70Vrms Strobe, Amber 130 WG4WA-SVMHC ED-WGWASVMHC 24VDC/FWR; Speaker/ 25 or 70Vrms Strobe WG4WF-H ED-WG4WFH 24VDC/FWR WG4WF-HVMC ED-WGWFHVMC 24VDC/FWR Horn 95 Horn/Strobe 15, 29, 70, 87 95 .127- .351 dc; .218- .422 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1, 2, 3 Horn/Strobe 102, 123, 147, 95 161 .342- .526 dc; .447- .679 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1, 2, 3 Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 WG4WF-HVMHC ED-WGWFHVMHC 24VDC/FWR WG4WF-S ED-WGWFS 25 or 70Vrms Speaker 81, 84, 87, 90 WG4WF-SVMC Speaker/ ED-WGWFSVMC 24VDC/FWR; 25 or 70Vrms Strobe 15, 29, 70, 87 81, 84, 87, 90 .106- .319 dc; .120-.376 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 102, 123, 147, 81, 84, 87, 90 161 .324- .495 dc; .412- .646 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 .069 dc; .135fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1, 2, 3 WG4WF-SVMHC ED-WGWFSVMHC 24VDC/FWR; Speaker/ 25 or 70Vrms Strobe WG4WN-H ED-WGWNH 24VDC/FWR WG4WN-HVMC ED-WGWNHVMC 24VDC/FWR Horn 95 Horn/Strobe 15, 29, 70, 87 95 .127- .351 dc; .218- .422 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1, 2, 3 Horn/Strobe 102, 123, 147, 95 161 .342- .526 dc; .447- .679 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1, 2, 3 Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 WG4WN-HVMHC ED-WGWNHVMHC 24VDC/FWR WG4WN-S ED-WGWNS 25 or 70Vrms Speaker WG4WN-SVMA Speaker/ ED-WGWNSVMA 24VDC/FWR; 25 or 70Vrms Strobe, Amber 13, 25, 59, 62 81, 84, 87, 90 .106- .319 dc; .120-.376 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 WG4WN-SVMC Speaker/ ED-WGWNSVMC 24VDC/FWR; 25 or 70Vrms Strobe .106- .319 dc; .120-.376 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 81, 84, 87, 90 .324- .495 dc; .412- .646 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 102, 123, 147, 81, 84, 87, 90 161 .324- .495 dc; .412- .646 fwr Wall or Ceiling W.P - Outdoor; 4"sq x 1-1/2 Indoor 1,3 All Available S/D/4" Sq. 1, 2, 3, 4, 5, 6 81, 84, 87, 90 15, 29, 70, 87 81, 84, 87, 90 WG4WN-SVMHA ED-WGWNSVMHA 24VDC/FWR; Speaker/ 84, 101, 125, 25 or 70Vrms Strobe, Amber 130 WG4WN-SVMHC ED-WGWNSVMHC 24VDC/FWR; Speaker/ 25 or 70Vrms Strobe EG1M-RM 24VDC ED-EG1MRM Sync Mod FIRE Edwards Signaling (Cont’d) APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 149 FIRE Notification Appliance Comparison Chart Gentex Vendor Model Number Part Number Operating Voltage Strobe Candella Unit Type DBA Rating Current Draw Mounting Options Box Type Approvals Listing GX93R GN-GX93R 12/24VDC Temp Horn 90 21mA Universal S/D/4" Sq. 1, 2, 3, 4, 6 GX93W GN-GX93W 12/24VDC Temp Horn 90 21mA Universal S/D/4" Sq. 1, 2, 3, 4, 5, 6 GEH24-R GN-9041205 24VDC Horn 100 15-56mA Universal S/D/4" Sq. 1, 2, 3, 4, 5, 6 GEC241575WR GN-9041127 24VDC Horn/Strobe 15/75 104 82-123mA Wall D/4" Sq. 1, 2, 3, 4, 5, 6 GES241575WR GN-9041167 24VDC Strobe 15/75 67mA Wall D/4" Sq. 1, 2, 3, 4, 5, 6 GEC312WR GN-9041231 12VDC Horn/Strobe Selectable 100 115-335mA Wall D/4" Sq. 1, 2, 3, 4, 6 GEC324WR GN-GEC324WR 24VDC Horn/Strobe Selectable 100 65-184mA Wall S/D/4" Sq. 1, 2, 3, 4, 6 GES312WR GN-GES312WR 12VDC Strobe Selectable 92-312mA Wall S/D/4" Sq. 1, 2, 3, 4, 6 GES324WR GN-GES324WR 24VDC Strobe Selectable 42-161mA Wall S/D/4" Sq. 1, 2, 3, 4, 6 GCC24-CR GN-GCC24CR 24VDC Horn/Strobe Selectable 143-344mA Ceiling D/4" Sq. 1, 2, 3, 4, 6 GCS24-CR GN-GCS24CR 24VDC Strobe Selectable 120-321mA Ceiling D/4" Sq. 1, 2, 3, 4, 6 WGEC24-75WR GN-WGEC75WR 24VDC Horn/ Strobe 75 185.226mA Wall GOE 1, 2, 3, 4, 6 WGES24-75WR GN-9041219 24VDC Strobe 75 170mA Wall GOE 1, 2, 3, 4, 6 SSPK24WLPR GN-9041413 24VDC Speaker/ Strobe Selectable 78-96mA Wall S/D/4" Sq. 1, 2, 3, 4, 6 SSPKCLPW GN-9041446 24VDC Speaker Universal S/D/4" Sq. 1, 2, 3, 4, 6 GHLFW GN-GHLFW 24VDC Horn 77.8-83.4 72.1-116.0 Universal D/4" sq. 1,2,3,6 GHLFR GN-GHLFRW 24VDC Horn 77.8-83.4 72.1-116.0 Universal D/4" sq. 1,2,3,6 95 100 APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago 150 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Notification Appliance Comparison Chart Vendor Model Number Part Number SCMC24C177 AS-SC24C177R/W SCM24W75110 SCMC24C3075110 Operating Voltage Strobe Candella DBA Rating Current Draw Mounting Options Box Type Approvals Listing Chime Strobe 177 65 .191 - .390 Universal S/D/4" Sq. 1, 2, 3, 4 AS-S24W75110 16-33VDC Chime Strobe 75/110 65 .100 - .200 Universal S/D/4" Sq. 1, 2, 3, 4 AS-24C307511R 16-33VDC Chime Strobe 30/75/110 105 .113 - .269 Universal S/D/4" Sq. 1, 2, 3, 4 SL24C3075110 AS-SLC375110 16-33VDC Strobe 30/75/110 .072 - .242 Universal S/D/4" Sq. 1, 2, 3, 4 SL24C177 AS-SL24C177R/W 16-33VDC Strobe 177 .191 - .390 Universal S/D/4" Sq. 1, 2, 3, 4 SH24C3075110 AS-SH24C375R 16-33VDC Horn/Strobe 30/75/110 100 .138 - .273 Universal S/D/4" Sq. 1, 2, 3, 4 SH24C177 ASSH24C177R/W 16-33VDC Horn/Strobe 177 100 .220 - .419 Universal S/D/4" Sq. 1, 2, 3, 4 9-33VDC Strobe 12V - 15, 35, or 60 24V - 15, 35, 60, 75, 95, or 110 .061 - .196 Wall S/D/4" Sq. 1, 2, 3 9-33VDC Weatherproof Strobe 12V - 15, 35, or 60 24V - 15, 35, 60, 75, 95, or 110 .100 - .225 Wall BBK-1 or BBX-5 1, 2, 3 9-33VDC Horn/Strobe 12V - 15, 35, or 60 24V - 15, 35, 57-87 60, 75, 95, or 110 .061 - .283 Wall S/D/4" Sq. 1, 2, 3 12V - 15, 35, or 60 24V - 15, 35, 57-87 60, 75, 95, or 110 .100 - .312 Wall BBK-1 or BBX-5 1, 2, 3 SL-1224 SL-1224WP SH-1224 AS-SL1224 AS-SL1224WP AS-SH1224 16-33VDC Unit Type SH-1224WP AS-SH1224WP 9-33VDC Weatherproof Strobe/Horn SH-24H AS-SH24H 16-33VDC High Intensity 95, 110, 135, 57-87 Strobe/Horn 150, 177, 185 .151 - .313 Wall S/D/4" Sq. 1, 2, 3 SL-24H AS-SL24H 16-33VDC High Intensity 95, 110, 135, Strobe 150, 177, 185 .151 - .226 Wall S/D/4" Sq. 1, 2, 3 SH-120 AS-SH120 96-132VDC Horn/Strobe 110 .100 Wall S/D/4" Sq. BBX-5 1, 3 SL-120 AS-SL120 96-132VDC Strobe 110 .100 Wall S/D/4" Sq. BBX-5 1, 3 SS-2 AS-SS2 25V RMS or 70V RMS Speaker Square 81-89 Wall or Ceiling 4BX-3 or 4BX-5 1 SR-2 AS-SR2 25V RMS or 70V RMS Speaker Round 81-89 Wall or Ceiling 4BX-3 or 4BX-5 1 SSS-2 AS-SSS2 25V RMS or 70V RMS Strobe/ Speaker Square 15/30 or 75/110 81-89 .64 - .189 Wall or Ceiling 4BX-3 or 4BX-5 1 SSR-2 AS-SSR2 25V RMS or 70V RMS Strobe/ Speaker Round 30, 75, 95 or 177 81-89 .116 - .274 Wall or Ceiling 4BX-5 1 SS-8 AS-SS8 25V RMS or 70V RMS Speaker Square 90-94 Wall or Ceiling 4BX-3 or 4BX-5 1 SR-8 AS-SR8 25V RMS or 70V RMS Speaker Round 90-94 Wall or Ceiling 4BX-3 or 4BX-5 1 SSS-8 AS-SSS8 25V RMS or 70V RMS Strobe/ Speaker Square 15/30 or 75/110 90-94 .64 - .189 Wall or Ceiling 4BX-3 or 4BX-5 1 SSR-8 AS-SSR8 25V RMS or 70V RMS Strobe/ Speaker Round 30, 75, 95 or 177 90-94 .116 - .274 Wall or Ceiling 4BX-5 1 57-87 FIRE Potter APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 151 FIRE Notification Appliance Comparison Chart System Sensor Vendor Model Number Part Number Operating Voltage Unit Type Strobe Candella DBA Rating Current Draw Mounting Options Box Type Approvals Listing PC2R BK-PC2R 12/24VDC & FWR Horn/Strobe 15 to 115 88 91 to 229 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 PC2RH BK-PC2RH 12/24VDC & FWR Horn/Strobe 135 to 185 88 228 to 286 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 P2R BK-P2R 12/24VDC & FWR Horn/Strobe 15 to 115 88 91 to 229 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 P2RH BK-P2RH 12/24VDC & FWR Horn/Strobe 135 to 185 88 255 to 309 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 P2W BK-P2W 12/24VDC & FWR Horn/Strobe 15 to 115 88 91 to 229 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 P2WH BK-P2WH 12/24VDC & FWR Horn/Strobe 135 to 185 88 255 to 309 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 P2RK BK-P2RK 12/24VDC & FWR Outdoor Horn/ 15 to 115 Strobe 88 91 to 229 Universal Outdoor (Incl.) 1, 2, 3, 4, 5 P2RHK BK-P2RHK 12/24VDC & FWR Outdoor Horn/ 135 to 185 Strobe 88 255 to 309 Universal Outdoor (Incl.) 1, 2, 3, 4, 5 SCR BK-SCR 12/24VDC & FWR Strobe 15 to 115 66 to 210 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 SCRH BK-SCRH 12/24VDC & FWR Strobe 135 to 185 228 to 286 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 SR BK-SR 12/24VDC & FWR Strobe 15 to 115 66 to 210 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 SRH BK-SRH 12/24VDC & FWR Strobe 135 to 185 228 to 286 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 SW BK-SW 12/24VDC & FWR Strobe 15 to 115 66 to 210 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 SWH BK-SWH 12/24VDC & FWR Strobe 135 to 185 228 to 286 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 SRK BK-SRK 12/24VDC & FWR Outdoor Strobe 15 to 115 66 to 210 Universal Outdoor (Incl.) 1, 2, 3, 4, 5 SRHK BK-SRHK 12/24VDC & FWR Outdoor Strobe 135 to 185 228 to 286 Universal Outdoor (Incl.) 1, 2, 3, 4, 5 SW-ALERT BK-SWALERT 12/24VDC & FWR Amber Lens Strobe 15 to 115 66 to 210 Wall S/D 4" Sq./Oct. 1, 3 SWH-ALERT BK-SWHALERT 12/24VDC & FWR Amber Lens Strobe 135 to 185 228 to 286 Wall S/D 4" Sq./Oct. 1, 3 HR BK-HR 12/24VDC & FWR Horn 88 69 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 HW BK-HW 12/24VDC & FWR Horn 88 69 Universal 2, 3, S/D 4" Sq./Oct. 1, 4, 5 HRK BK-HRK 12/24VDC & FWR Outdoor Horn 88 69 Wall Outdoor (Incl.) 1, 2, 3, 4, 5 MHR BK-MHR 12/24VDC & FWR Mini Horn 78 14 - 29 Wall S/4" Sq. 1, 3, 4, 5 MHW BK-MHW 12/24VDC & FWR Mini Horn 78 14 - 29 Wall S/4" Sq. 1, 3, 4, 5 APPROVAL LISTING 1 = UL, Underwriters Laboratories 2 = ULC, Underwriters Laboratories of Canada 3 = CSFM, California State Fire Marshall 4 = MEA, New York City 5 = FM, Factory Mutual 6 = BFP, Chicago 152 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Notification Appliances & Accessories Single Action Manual Pull Station •4 wire pigtail connection •Surface mounting or semi-flush mounting Explosion-Proof Strobe Light FIRE Manual Pull Station •Low current draw •15 candela •Available in wall or ceiling mount and red lens FD-LSEX24WMC (LSEX24WMC) FD-4050001T (405001T) Explosion-Proof Pull Station •Enclosure is made of copper free aluminum alloy •120VAC 60 Hz 6 Amps with 3/4" NPT feed through conduit FD-MPEX (MPEX) Speaker Cluster •Operating voltage 24VDC polarized •Wide selection of tones (U-TC) •4 speaker cluster for 360 coverage indoor and outdoor mounting •Voice capable with PTCK audio connector card FD-ASHP4CLMU (ASHP-4CLMR-U) Explosion-Proof Horn •Nema 4X rated •Corrosion resistant cast aluminum •UL Sound pressure level 94 dB at 10 feet FD-FHEX24SMR (FHEX24SMR) Amplified Speakers •Stand-alone 24VDC operation using tone card FD-UTC •Indoor and outdoor mounting •Available in hazardous or explosion proof •Compatible with voice systems with FD-PTCK25 or FD-PTCK70 Evacuator •Evacuation message (special order up to 4 minute message capacity) •25 or 70 Vrms field selectable •Works with 12VDC or 24VDC fire alarm panel •Works with analog/addressable and conventional fire alarm panels FD-CE25 (CE1-P-25DM) FD-CE50 (CE1-P-50DM) FD-CE100 (CE1-P-100DM) FD-ASHP24SMR (ASHP24SMR) High Output Speaker •Operates on 25 Vrms or 70 Vrms •Multiple power taps 0.5,1,2,7, and 15 •Indoor and outdoor mounting •Available in hazardous or explosion proof FD-SPHPDVSMR (SPHPDVSMR) For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 153 FIRE Notification Appliances & Accessories 177 Candela ADA Strobe •120VAC •177 candela ADA compliant strobe light •Compatible with BRK/First Alert smoke and CO alarms •10 year limited warranty BR-SL177 (SL177) Equipment Panel Circuit Surge Protection Complete Fire Control Panel Protection •120VAC power protection, 20A max current •Compact design, parallel connection •Diagnostic LED indicates ground presence, system power and SPD function DK-120HW (DTK-120HW) GET IT •AC Power alarm panel protector and 5-position hardwire base, installed in a Nema 1 steel enclosure •Designed to protect 120VAC power, and up to ten SLC, IDC, NAC and dialer circuits (modules sold separately) •Contact your ADI representative for configuration assistance DK-TSS1 (DTK-TSS1) NOW! Alarm Panel Loop Circuit Protection Kit •2-position hardwire base, installed in Nema 4X enclosure •Designed to protect up to four SLC/IDC/NAC and dialer circuits (modules sold separately) •Perfect for protecting building-to-building communication loops •Also available with 120VAC protection (DK-TSS2) Fire Control Panel Power Protection Kit •120VAC power supply protection, 20A max current. EMI/RFI noise filtering. •Nema 4X enclosure approved for indoor and outdoor applications •Dry contacts for remote monitoring Fire Control Panel Power Protector •54kA Series connected AC Power protection •120V-20A device with UL1283 EMI/RFI noise filtering •Dry contacts for remote monitoring DK-120SRD (DTK-120SRD) DK-TSS4D (DTK-TSS4D) DK-TSS3 (DTK-TSS3) GET IT NOW! Fire Alarm Panel Surge Protection Wheelock Weather-Resistant Back Box •Protects 1 or 2 pairs of SLC loops. Series connection, parallel function adds no resistance to loop circuits. DK-2LVLPF (DTK-2LVLPF) •Weather-resistant back box •Sturdy die cast housing, threaded conduit hole and knockout for outdoor applications •Shown in red – also available in white WH-102959 (WBB-R) Wheelock Weather Proof Surface Mount Back Box •Surface Mount Back Box •For surface mounting for Wheelock Series AS Weatherproof Appliances •Shown in red – also available in white WH-109014 (WPBB-R) GET IT NOW! 154 GET IT GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us NOW! Get It Now! Notification Appliances & Accessories FIRE Wheelock Weatherproof Backbox Wheelock Series MB Motor Bell •Backbox for series RSSWP strobe •Weatherproof •Red Wheelock Series MIZ Mini Horn •High performance motor bell for fire and life safety •High sound output with low current draw •Built-in trimplate for semi-flush mounting •6" low frequency aluminum shells WH-109751 (WPSBB-R) •High sound output mini horn •24VDC, wall mount, white •Continuous or Code 3 output •Mount to single–gang back boxes WH-138484 (MIZ-24S-W) WH-103941 (MB-G6-24-R) GET IT GET IT NOW! NOW! Wheelock Exceder Wall Horn Strobe •Finger slide switches, voltage test points •Selectable 12/24VDC, 3 audible settings (90, 95, 99) •8 candela settings: 15/1575/75/95/110/135/185 WH-HSR (HSR) •Red WH-HSW (HSW) New! Wheelock Exceder LED Strobe New! Wheelock Exceder LED Horn Strobe •Industry’s first LED appliances •Save up to 52% in current draw •Low profile, compact single gang design •4 Selectable candela settings •Industry’s first LED appliances •Save up to 52% in current draw •Low profile, compact single gang design •4 Selectable candela settings, wall mount WH-LSTR (LSTR) WH-LHSR (LHSR) Wheelock Exceder Wall Mount Strobe New! Wheelock Exceder LED Horn Strobe •White GET IT NOW! Wheelock Exceder Wall Mount Strobe •Voltage test points; selectable 12/24VDC •Wall mount, red, strobe •Eight candela settings: 15/1575/75/95/110/135/185 Low current draw WH-STR (STR) •Voltage test points, selectable 12/24VDC •Eight candela settings: 15/1575/75/95/110/135/185 •Universal mounting base •Low current draw WH-STW (STW) •Low-profile, small footprint design •Industry’s lowest current draw •Easy-to-install with finger slide switches •4 convenient mounting options WH-LHSW (LHSW) GET IT NOW! GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 155 FIRE Notification Appliances & Accessories Wheelock Exceder Ceiling Horn Strobe Wheelock Exceder Ceiling Horn Strobe Wheelock Exceder Ceiling Strobe •Selectable 12/24VDC, 3 audible settings (90, 95, 99). Finger slide switches. •Eight candela settings: 15/1575/75/95/115/150/177 •Selectable 12/24VDC, 3 audible settings (90, 95, 99). Finger slide switches. •Eight candela settings: 15/1575/75/95/115/150/177 •Selectable 12/24VDC. Low current draw. •Ceiling mount, red, strobe •Eight candela settings: 15/1575/75/95/115/150/177 WH-HSWC (HSWC) WH-HSRC (HSRC) GET IT GET IT Wheelock Speaker Strobes Wheelock Exceder Ceiling Strobe •Selectable 12/24VDC •Eight candela settings: 15/1575/75/95/115/150/177 •Universal mounting base - mounts to 5 backbox WH-STWC (STWC) GET IT WH-109023 (E70-24MCW-FW) GET IT NOW! Wheelock Exceder LED Horn Strobe •2 Watt speaker strobe •Round, ceiling •24VDC,15/30/75/95cd •White •Ceiling mount LED horns strobe •Industry’s lowest current draw •Selectable 15/30/75/95cd •Also available in red WH-113166 (E90-24MCC-FW) NOW! GET IT NOW! Wheelock Ceiling Speaker Strobe WH-113747 (E60-24MCC-FW) •High efficiency sound output •Dual voltage (25/70 VRMS) capability •Field selectable taps from 1/8 to 2 Watts •Selectable candela settings of 15/30/75/110cd GET IT NOW! •Mounting ceiling, input voltage selectable 25/70 VRMS. Selectable taps 1/8 - 2 Watts. •Grills snap-on plastic, round •Strobe candela selectable 15/30/75/95 NOW! Wheelock Speaker Strobe •High efficiency sound output •Dual voltage (25/70 VRMS) capability •Field selectable taps from 1/8 to 2 Watts •Selectable candela settings of 15/30/75/110cd WH-109022 (E70-24MCW-FR) Wheelock Speaker Strobe GET IT NOW! NOW! 156 WH-STRC (STRC) WH-LHSWC (HSWC) GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Notification Appliances & Accessories FIRE Wheelock Exceder LED Strobe Wheelock Speaker Strobe •Low current ceiling strobe, white •Selectable 15/30/75/95cd •Low profile design •Easy to install with finger slide switches Weatherproof Horn Strobe •Input voltage selectable 25/70 VRMS •Selectable taps 1/8 - 2 Watts •Snap-on grills, wall, white •Strobe candela selectable 15/30/75/110 WH-LSTWC (LSTWC) •Weatherproof horn strobe, red, wall mount •Temperature range: -31° F to 150° F •24VDC WH-129012 (ASWP-2475W-FR) WH-110227 (E50-24MCW-FW) GET IT GET IT NOW! Wheelock Sync Module Wheelock Weatherproof Strobe Wheelock Exceder LED Strobe •Sync module •2 Class “B” or 1 Class “A” circuit •Red •Weatherproof strobe, red, wall mount •Temperature range: -31° F to 150° F •24VDC •Industry’s lowest current draw •15/30/75/110 cd, wall mount, white •Low profile, single gang design •LED strobe - Save on power WH-126374 (DSM-12/24-R) WH-129013 (RSSWP-2475W-FR) NOW! WH-LSTW (LSTW) GET IT GET IT NOW! Wheelock Exceder LED Speaker •Wall mount speaker, white •Crisp, clear voice messages; 300-8000 Hz 1/8 to 2 Watts, 25/70 VRMS •High fidelity sound output, low profile WH-LSPKW (LSPKW) NOW! Wheelock Exceder LED Speaker Strobe •Leading intelligibility - crisp, clear voice messages •Widest frequency range - 300 to 8000 Hz •5 field selectable taps - 1/8 up to 2 Watts •LED technology delivers lowest current draw WH-LSPSTR (LSPSTR) Wheelock Exceder LED Speaker Strobe •Leading intelligibility - crisp, clear voice messages •300 - 8000 Hz frequency range •Field selectable taps 1/8-2 Watts •4 field selectable candela settings WH-LSPSTW (LSPSTW) For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 157 FIRE Notification Appliances & Accessories Wheelock Exceder LED Speaker Strobe •Ceiling mount speaker strobe, white •Crisp, clear voice messages; 300-8000 Hz •1/8 to 2 Watts, 25/70 VRMS, 15/30/75/95cd •High fidelity sound output, low profile WH-LSPSTWC (LSPSTWC) Wheelock Exceder LED Speaker •Ceiling mount speaker, white •Crisp, clear voice messages; 300-8000 Hz •1/8 to 2 Watts, 25/70 VRMS •High fidelity sound output, low profile WH-LSPKWC (LSPKWC) Wheelock Exceder Low Frequency Sounder Strobe •Low frequency sounder for sleeping rooms •4 Settings: T3, T4, Continuous, T3/T4 •Avail with Alert, Fire, CO or no lettering •Selectable 15/30/75/110cd, white WH-LLFHSW (LLFHSW) Wheelock Exceder Low Frequency Sounder Strobe Wheelock Exceder Low Frequency Sounder Wheelock Exceder Low Frequency Sounder •Low frequency sounder for sleeping rooms •4 Settings: T3, T4, Continuous, T3/T4 •Avail with Alert, Fire, CO or no lettering •Selectable 15/30/75/110cd, red •Low frequency sounder for sleeping rooms •4 Settings: T3, T4, Continuous, T3/T4 •Avail with Alert, Fire, CO or no lettering •Low-profile design, white •Low frequency sounder for sleeping rooms •4 Settings: T3, T4, Continuous, T3/T4 •Avail with Alert, Fire, CO or no lettering •Low-profile design, red WH-LLFHSR (LLFHSR) WH-LLFHNWN (LLFHNWN) WH-LLFHNRN (LLFHNRN) GET IT GET IT NOW! NOW! By INTERLOGIX Wheelock Speaker Wheelock Exceder LED Speaker •2 Watt speaker •Round •Wall or ceiling mount •Wall mount speaker, red •Crisp, clear voice messages; 300-8000 Hz •1/8 to 2 Watts, 25/70 VRMS •High fidelity sound output, low profile WH-117869 (E90-W) WH-LSPKR (LSPKR) DH Series Electromagnetic Door Holders •360° swivel mount reduces installation time •Flexible available mounting hardware ES-DHS24120C (DHS-24120C) •Chrome surface mount ES-DHF24120C (DHF-24120C) •Chrome semi-flush mount ES-DHER3C (DH-ER3C) GET IT NOW! 158 •Chrome 3" extension rod For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! GET IT NOW! Notification Appliances & Accessories Image Not Shown DH Series Electromagnetic Fire Door Holders •24V DC/V AC 120V AC •Recess-mount •Chrome •3" extension rod included Addressable Monitor Module FIRE By INTERLOGIX SLC Module •Class A or B IDC (dry contact input devices) •Provides interface to contact devices, waterflow switches or pull stations FL-MMF300 (MMF300) •Optional SLC loop module for MS-9600LS or MS-9600UDLS •159 detectors & 159 control/relay/monitor modules FL-SLC2LS (SLC-2LS) ES-DHR24120C (DHR-24120C) GET IT NOW! Remote Power Supply/Sync Commander3 Colored Lens Series •UL Listed for 2 operating modes •4/6 Amps in standalone & 6/8 Amps in expander mode. Integral battery charger up to 18AH. •Built-in NAC sync FL-FCPS24FS6 (FCPS24FS6) FL-FCPS24FS8 (FCPS24FS8) Commander2 Horns, Strobes and Horn/Strobe GN-9041327 (GECA24WPR) •Amber •24VDC horns, strobes and horn/strobes •SuperSlide® - test for supervision •Checkmate® - instant voltage verification GN-9041330 (GECB24PWW) •Blue GN-9041331 (GECG24PWR) •Green GN-9041127 (GEC24-15/75WR) GN-9041333 (GECR24PWR) •Fixed candela 15/75 •Red GN-9041143 (GEC24-177WR) •Fixed candela 177 GET IT NOW! Commander3 Strobe and Horn/Strobe •24VDC strobe and horn/strobes Commander Outdoor Series GEP/GEPS Colored Lens Expander Plate •24VDC strobe or horn/strobe, shipped as a kit •Features supervision test and voltage verification abilities. Wall mount, red or white faceplate. •Fixed 75 candela strobe and field selectable tones GN-GEC324WW (GEC3-24WW) GN-GEC324WR (GEC3-24WR) GN-GES324WW (GES3-24WW) GN-GES324WR (GES3-24WR) GN-WGEC75WR (WGEC24-75WR) GET IT NOW! •24VDC strobe only expander plate available in amber, blue, green & red lens •Use in conjunction with Gentex speaker or wall mount speaker/strobe •Amber lens models field selectable candela, blue, green & red fixed candela GN-GEPA (GEPA) GN-GEPB (GEPB) GN-GEPG (GEPG) GN-GEPR (GEPR) GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 159 FIRE Notification Appliances & Accessories Commander Outdoor Colored Lens Series •24VDC strobe or horn/strobe available •Fixed 75 candela. Field selectable tones. •Features SuperSlide® bracket & Checkmate® voltage verification •Amber GN-9041343 (WGECA24-75PWR) Outdoor Speaker and Speaker/Strobe •24VDC strobe operation •25 or 70.7 VRMS. Field selectable power taps: 1/8, 1/4, 1/2, 1, 2 or 4 Watts. •Frequency range: 400-4000 Hz GN-9041437 (WSSPKR) •Speaker GN-9041433 (WSSPK24-15/75WR) •Speaker/strobe has fixed 15/75 candela strobe Outdoor Colored Lens Speaker/Strobe •24VDC strobe operation with fixed 15/75 candela strobe •25 or 70.7 VRMS and frequency range 400 - 4000 Hz GN-9041421 (WSSPKA24) •Amber GN-9041423 (WSSPKB24) •Blue GN-9041425 (WSSPKG24) Wall Mount Speaker/Strobes Commander4 Colored Lens Series GN-9041375 (GCCA24PCR) •24VDC strobe operation •Frequency range: 400 - 4000 Hz. Field selectable power taps: 1/8, 1/4, 1/2, 1, 2 or 4 Watts. •Tamperproof field selectable candela options: 15, 30, 60, 75 and 110 •Fixed 15/75 candela model also available •Mounts to a 4" x 2-1/8" square deep back box •Amber GN-9041378 (GCCB24PCW) •Blue GN-9041379 (GCC2G4PCR) •Green GN-9041381 (GCCR24PCR) •Red GN-9041413 (SSPK24WLPR) GN-9041415 (SSPK24WLPW) Ceiling Mount Speaker/Strobes Universal Mount Speaker •24VDC strobe operation •25 or 70.7 VRMS •Field selectable power taps: 1/8, 1/4, 1/2, 1, 2 or 4 Watts •Tamperproof field selectable candela options: 15, 30, 75, 95 & 115 •25 or 70.7 VRMS •Frequency range: 400 - 4000 Hz •Field selectable power taps: 1/8, 1/4, 1/2, 1, 2 or 4 Watts. Ceiling or wall mount applications. •Mounts to a 4" x 2-1/8" square deep back box GN-9041445 (SSPKCLPR) •Red GN-9041441 (SSPK24CLPR) GN-9041443 (SSPK24CLPW) GN-9041446 (SSPKCLPW) Commander4 Strobes and Horn/Strobe Synchronization Module •White •Tamperproof field select. candelas: 15, 30, 75, 95, 115 & 150. 24VDC strobe and horn/strobe. •Field selectable tones. Features SuperSlide® bracket. GN-GCC24CR (GCC24CR) GN-GCC24CW (GCC24CW) GN-GCS24CR (GCS24CR) GN-GCS24CW (GCS24CW) •Synchronize horn and strobe with only 2 wires •Module is rated for 3 Amps continuous current and 5 Amps surge or in-rush current •Option to silence horn while strobe continue to flash •Operates 1 class A circuit or 2 class B circuits GN-9041243 (AVSMR) •Green GET IT NOW! 160 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Notification Appliances & Accessories FIRE Remote Visual Signal •120VAC, terminal blocks, fixed 177 candela strobe •Wall and ceiling mount models •Wide variety of mounting options GN-9040780 (GXS120-177WR) Mini Horns Low Frequency Audible Signal •Field selectable 12VDC or 24VDC operation •Field selectable continuous or temporal 3 sounder •Horn frequency of 3100 Hz •Terminal blocks (12-18AWG) GN-GX93R (GX93R) •Nominal Voltage 24VDC •Produces 520 Hz low frequency temporal 3 tone •Temporal 4 pattern available when used with GTSM synchronization model •Low current draw GN-GHLFW (GHLFW) •Red •White faceplate GN-GX93W (GX93W) GN-GHLFR (GHLFR) •White •Red faceplate GET IT NOW! Fire Alarm Bells - 24VDC •4-wire operation •Mounts to 4" square electrical box •18AWG wire leads •Outdoor listed when used with Gentex GBBB back box RELOCATOR for Pull Station Visual Mass Notification Display •The RELOCATOR is designed to lower the height of a fire alarm Pull Station, strobe or horn strobe combination to meet the ADA requirements. LE-RELW (RELOCATOR) GN-9041278 (GB6-24) •6" housing •Provides 2 visual notifications for evacuate or announcement •High brightness LED bars backlight message •Power from NAC circuit •Custom message wording also available LE-SPCM (SP Series) GN-9041279 (GB10-24) •10" housing Special Application Manual Stations •Single action •Gold plated SPST contacts •Two Form C Contacts •Key resettable •N.O. or N.C. Alarm Contacts Bell •Environment: -40° - 150° F, indoor or outdoor use •Sizes available: 6", 8", 10"/available voltage: 24VAC, 120VAC, 12VDC, 24VDC PL-MBA1024 (MBA-1024) MI-MS703U (MS-703U) OSYSU-1 Outside Screw and Yoke Valve Supervisory Switch •NEMA 6P (submersible) •Factory installed neoprene gasket •One set of SPDT (Form C) •Fits 1/2"-12" valves PL-OSYSU1 (OSYSU-1) •Blue finish MI-MS704U (MS-704U) •Yellow finish GET IT GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us NOW! Get It Now! 161 FIRE Notification Appliances & Accessories OSYSU-2 Outside Screw and Yoke Valve Supervisory Switch VSR Vane Type Waterflow Alarm Switch with Retard •NEMA 4 solid metal enclosure •Factory installed neoprene gasket •0-90 second field replaceable pneumatic retard •Versions available from 2.5" to 10" •NEMA 6P (submersible) •Factory installed neoprene gasket •Two sets of SPDT (Form C) •Fits 1/2"-12" valves PL-VSR4 (VSR-4) PL-OSYSU2 (OSYSU-2) PCVS-2 Control Valve Supervisory Switch •NEMA 6P (submersible) •Factory installed neoprene gasket •Two sets of SPDT (Form C) •1/2" male NPT fitting PL-PCVS2 (PCVS-2) •4" steel pipe PL-VSR6 (VSR-6) •6" steel pipe GET IT GET IT PTS-C Plug Type Supervisory Switch •Factory installed neoprene gasket •SPDT contacts 100mA @ 28VDC/AC, 250mA @ 12VDC/AC. SPDT cover tamper 250mA @ 28VDC/ AC. NEMA 6P (submersible). PL-PTSC (PTS-C) GET IT NOW! NOW! NOW! Surface Mount Magnetic Holder Floor Mount Magnetic Holder •Surface mount •Independently wound tri-voltage coils •Low amperage draw (.02 Amps) •Tamper-proof extension pieces •Independently wound tri-voltage coil •Low amperage draw (.02 Amps) •Tamper-proof extension pieces K7-980TRI689 (980) K7-996TRI689 (996) GET IT GET IT NOW! Semi-Recess Mount Door Magnetic Holder NOW! SafeAwake •A commercially approved smoke alarm notification device that awakens a sleeping person to a fire emergency; designed for the deaf, people with hearing disabilities or difficulties, and seniors. Seconds count in a fire! •Low amperage draw (.02 Amps) •Tamper proof extension pieces K7-998TRI689 (998) B9-SART9V10 (SART 9V 1.0) Conventional Dual Action Pull Station •Cost-effective with hex key reset •Operating instructions molded into handle along with Braille text •Made of durable Lexan SK-PSDAH (PSDAH) GET IT NOW! 162 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Notification Appliances & Accessories FIRE Remote Test Switch 6" Detector Base •Compatible with SK-SD505DUCTR •Uses same key as fire alarm control panel •LED status indication Fire Document Box •Compatible with SK-SD505AIS, SK-SD505APS and SK-SD505AHS •4" Detector Base also available P/N SK-SD5054AB SK-SD505DTSK (SD505DTSK) SK-SD5056AB (SD5056AB) •NFPA 72 code required records box-red •Holds records, keys, CD, cards etc. •Cat 30 lock optional lock sets available •Notes sticker for labeling inside O6-SSU00672 (SSU00672) GET IT GET IT NOW! Stopper II® Protective Cover Stopper II® Protective Cover Fire Circuit Lockout Kit •Helps prevent false fire alarms w/o restricting legitimate alarms •When lifted, cover emits 95/105 dB alarm drawing immediate attention, 9VDC •Clamps circiut to trip breaker •Protects critical systems •Reduces service calls •Includes labels and key GET IT GET IT SF-1200 (STI-1200) NOW! Conduit Spacer for Stopper II® Stopper II® Protective Cover •Helps prevent false fire alarms w/o restricting legitimate alarms •Without horn, for flush mounted units •3 year guarantee on poly. in normal use GET IT NOW! NOW! Stopper II® Protective Cover •Helps prevent false fire alarms w/o restricting legitimate alarms. Includes spacer. •When lifted, cover emits 95/105 dB alarm drawing immediate attention, 9VDC SF-1130 (STI-1130) SF-1100 (STI-1100) O6-ELOCKFA (ELOCK-FA) NOW! •Helps prevent false fire alarms w/o restricting legitimate alarms. Models with horn available. •Without horn, with spacer •Three year guarantee on poly. in normal use •Clear spacer. Has conduit knockouts. •Adds 2" of depth to Stopper II and Weather Stopper®: SF-1100, SF-1200 SF-3100 (STI-3100) SF-1230 (STI-1230) GET IT NOW! GET IT GET IT NOW! NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 163 FIRE Notification Appliances & Accessories Horn/Strobe Damage Stopper® Weather Stopper® Protective Cover •Protective cover helps prevent damage and vandalism •Open backbox with conduit knockout •Slots in cover allow horn to be heard SF-1210D (STI-1210D) •Helps prevent false fire alarms w/o restricting legitimate alarms. Without horn, with spacer. •NEMA 3R Rated, includes gaskets •Three year guarantee on poly. in normal use SF-3150 (STI-3150) GET IT SF-9601 (STI-9601) •Protects System Sensor SpectrAlert® Advance series strobes against vandalism and damage •9-gauge steel wire coated w/corrosion resistant white polyester. UL/cUL Listed; For surface mount. SF-9708 (STI-9708) •Quick to install - 2-piece grommet snaps together for an easy installation. Economical - Eliminates sleeves and the need for firestop putty or sealant. •Can be used for alarm, security, data (CAT 5 & 6) and electrical cables •Applications - single or grouped cables through 1 and 2 hour rated gypsum board wall X6-RFG2 (RFG2) GET IT NOW! Select-Alert Alarm Mini Controller •Helps stop unauthorized use of important devices •85 or 100 dB alarm offers 32 tones •Includes ten high intensity LEDs •Available in red, amber, blue, green or white SF-SA5000W (STI-SA5000-W) GET IT GET IT GET IT NOW! NOW! NOW! EZTM Firestop Grommet SF-9602 (STI-9602) NOW! Horn/Strobe/Speaker Damage Stopper® •Guard protects smoke detectors from vandalism and damage. 9-gauge coated steel wire. •Listed for any smoke detector, no sensitivity adjustment req. Low profile, flush mount. •Guard protects your smoke detectors from vandalism and damage, 9-ga. coated •Listed for any smoke detector, no sensitivity adjustment required GET IT NOW! Steel Web Stopper® Steel Web Stopper® SpecSeal® Series LCI Intumescent Firestop Sealant SpectrAlert Advance Outdoor Strobe •Highly intumescent: Expands up to 10X •Acoustically tested: Reduces sound transmission •UL Tested and Classified for all common constructions. UL leakage tested (L Ratings). •The SpectrAlert Advance SRK is a red, outdoor strobe •-40°F to 151°F (-40°C to 66°C) temperature rate BK-SRK (SRK) X6-LCI300 (LCI300) •Up to 0.53" (14mm) O.D. X6-RFG1 (RFG1) •Up to 0.27" (7mm) O.D. 164 GET IT GET IT NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us NOW! Get It Now! Notification Appliances & Accessories FIRE SpectrAlert Advance Horn Strobe Remote Annunciator •Red •4-wire •Horn strobe •Remote annunciator designed to work with duct smoke detectors •Red LED provides visual indication of an alarm condition BK-P4R (P4R) BK-RA100Z (RA100Z) White Amber Lens Dual Strobe with Speaker Plate •The SpectrAlert Advance BK-SEPSPSW is a White Speaker Strobe Expander Plate with a Standard Candela •White amber lens dual strobe with speaker plate with “ALERT”/plug-in design/standard candelas. This product is compatible with: SPSW, SPSWH, SPSW-P, SPSWV, SPSWV-P, SPSWH-P. BK-SEPSPSW (SEP-SPSW) GET IT GET IT NOW! SpectrAlert Advance Wall Mount Low Frequency Sounders •12 & 24VDC/FWR. Low frequency (520 Hz). •Mounts to single/double gang box, 4" x 4" and 4" octagonal boxes •Plug-in design. Wall & Ceiling. BK-HWLF (HW-LF) NOW! SpectrAlert Advance Wall Mounted Back Box SpectrAlert Advance Wall Mount Low Frequency Sounder Strobes •Red •Wall mounted •Back box •High candelas 135,150,177,185 •12 & 24VDC/FWR. Two tone selections. •Low Frequency tone (520 Hz) BK-SBBSPR (SBBSPR) BK-P2WHLF (P2WH-LF) •White •White BK-HRLF (HR-LF) BK-P2RHLF (P2RH-LF) •Red •Red SpectrAlert Advance Horn Strobe SpectrAlert Advance Surface Mount Back Box SpectrAlert Advance Horn Strobe •White •Indoor •Horn strobe •Red •Indoor •Horn strobe BK-P2W (P2W) •The SpectrAlert Advance SBBR is a surface mount red back box for wall installations BK-SBBR (SBBR) BK-P2R (P2R) GET IT NOW! GET IT GET IT NOW! NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 165 FIRE Notification Appliances Alarm Bells •Available in 6", 8", 10" 120V and 24V options BK-SSM246 (SSM246) •6" diameter – 24V GET IT NOW! BK-SSM2410 (SSM24-10) SpectrAlert Advance Wall Mount Speaker Strobes •10" diameter – 24V BK-SSV1206 (SSV1206) •Standard candelas: 15, 15/75, 30, 75, 95, 110, 115 •“P” suffix plain no-fire printed •“H” suffix candelas: 135, 150, 177, 185 •4 selectable tap settings (1/4 Watt to 2 Watts) •Strobe rated for 12 & 24VDC/FWR •Speaker 25 or 70.7 VRMS selectable •Plug-in design •Red or white •White clear lens strobe •Wall & ceiling BK-SPSR (SPSR) BK-SPSW (SPSW) BK-RP (RP) BK-RH (RH) BK-RHP (RHP) BK-WP (WP) BK-WH (WH) BK-WHP (WHP) •6" diameter – 120V SpectrAlert Advance Speakers •Plug-in design. 25 or 70.7 VRMS. •Four selectable taps (1/4 to 2 Watts) •Red or white. Wall and ceiling. BK-SPCW (SPCW) GET IT NOW! BK-SPW (SPW) BK-SPR (SPR) BK-SPCR (SPCR) GET IT NOW! SpectrAlert Advance High Volume Speakers •High dB output •Plug-in design •Four selectable taps (1/4 to 2 Watts) •25 or 70.7 VRMS •Red or white. Wall and ceiling. SpectrAlert Advance Wall Mount Horns •88dBA @ 16VDC •12 & 24 VDC/FWR •Three volume settings •Mounts to single/double gang, 4" x 4" and 4" octagonal boxes BK-HW (HW) BK-SPWV (SPWV) BK-SPRV (SPRV) BK-SPCWV (SPCWV) BK-SPCRV (SPCRV) SpectrAlert Advance Chimes & Chime Strobe BK-CHR (CHR) •Chime - Red •White BK-CHW (CHW) BK-HR (HR) •Chime – White •Red BK-CHSR (CHSR) •Chime/strobe - Red BK-CHSW (CHSW) SpectrAlert Advance Wall Mount Mini-Horn •Chime/strobe - White •12 or 24 Volt operation •High & low volume settings •Temporal or continuous tones •Able to be synchronized and ideal where a smaller notification device is desired BK-MHR (MHR) •Red BK-MHW (MHW) •White GET IT NOW! SpectrAlert Advance Ceiling Horn/Strobes •Plug-in mounting bracket design •Field selectable candela •Candelas: 15, 15/75, 30, 75, 95, 110, 115. Red or white. “H” suffix candelas: 135, 150, 177, 185. •“P” suffix plain no-fire printed •Three volume and temporal/ non-temporal settings BK-PC2R (PC2R) BK-PC2RH (PC2RH) BK-PC2W (PC2W) BK-PC2RP (PC2RP) BK-PC2WP (PC2WP) 166 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! GET IT NOW! & Accessories FIRE SpectrAlert Advance Ceiling Strobes •Plug-in mounting bracket design •Field selectable candela •Red or white •“P” suffix plain no-fire printed •Candelas: 15, 15/75, 30, 75, 95, 110, 115; “H” suffix candelas: 135, 150, 177, 185 BK-SCR (SCR) BK-SCW (SCW) BK-SCWP (SCWP) BK-SCRH (SCRH) BK-SCWH (SCWH) GET IT NOW! SpectrAlert Advance Wall Strobes •Standard candelas: 15, 15/75, 30, 75, 95, 110, 115 •“H” suffix candelas: 135, 150, 177, 185. Four selectable tap settings (1/4 Watt to 2 Watts). •Strobe rated for 12 & 24VDC/FWR •Plug-in design •Speaker 25 or 70.7 VRMS selectable BK-SPSCW (SPSCW) •Plug-in mounting bracket design •Field selectable candela •Red or white •“P” suffix plain no-fire printed •Candelas: 15, 15/75, 30, 75, 95, 110, 115; “H” suffix candelas: 135, 150, 177, 185 BK-SR (SR) BK-SW (SW) BK-SRP (SRP) BK-SWP (SWP) BK-SRH (SRH) BK-SWH (SWH) BK-SWHP (SWHP) SpectrAlert Advance Ceiling Mount Speaker/Strobes GET IT NOW! BK-WP (WP) BK-WH (WH) BK-WHP (WHP) BK-SPSCR (SPSCR) BK-RH (RH) GET IT NOW! SpectrAlert Advance Emergency Communications Strobes SpectrAlert Advance High Volume Wall Mount Speaker Strobes •High dB output. Plug-in design. •Strobe rated for 12 & 24VDC/FWR •Standard candelas: 15, 15/75, 30, 75, 95, 110, 115. Red or white. •Speaker 25 or 70.7 VRMS selectable BK-SPSWV (SPSWV) BK-SPSRV (SPSRV) •White amber lens strobe with “ALERT”. Standard candela: 15, 15/75, 30, 75, 95, 110, 115. BK-SWALERT (BK-SWALERT) •White ceiling clear lens strobe with “ALERT” BK-SCWCLRALR (BK-SCWCLRALERT) SpectrAlert Advance Emergency Communications Speaker Strobes •White amber lens strobe with “ALERT” SpectrAlert Advance High Volume Ceiling Mount Speaker/Strobes •High dB output. Plug-in design. •Red or white •Speaker 25 or 70.7 VRMS selectable •Standard candelas: 15, 15/75, 30, 75, 95, 110, 115 •“H” suffix candelas: 135, 150, 177, 185. Four selectable tap settings (1/4 Watt to 2 Watts). •Strobe rated for 12 & 24VDC/FWR BK-SPSWALERT (SPSWALERT) BK-SPSCWCLRA (SPSCWCLRALERT) •White ceiling clear lens speaker strobe with “ALERT” BK-SPSWCLRAL (SPSWCLRALERT) •White wall clear lens speaker strobe with “ALERT”. Four selectable tap settings (1/4 Watt to 2 Watts). •Standard candelas. Plug-in design. •Candela: 15, 15/75, 30, 75, 95, 110, 115 BK-SPSCWV (SPSCWV) BK-WVP (WVP) BK-WVH (WVH) BK-SPSCRV (SPSCRV) BK-RVH (RVH) For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 167 FIRE Notification Appliances SpectrAlert Advance Outdoor Wall Horn/Strobe •2-wire and 4-wire •Field selectable candela •Plastic weatherproof back box included •-40° F to 151° F temperature rate SpectrAlert Advance Outdoor Speakers BK-P2RK/RKP (P2RK/RKP) BK-P2RHK/RHKP (P2RHK/RHKP) BK-P2WK/WKP (P2WK/WKP) BK-P2WHK/WHKP (P2WHK/WHKP) BK-P4RK (P4RK) BK-P2RHK120 (P2RHK120) BK-P4WK (P4WK) •-40° F to 151° F temperature rate •NEMA 4X rated. 25 or 70.8 VRMS. •Plastic weatherproof back box included •Wall mount available in red or white BK-SPWK (SPWK) BK-SPRK (SPRK) BK-SPCWK/WHK (SPCWK/WHK) SpectrAlert Advance Outdoor Ceiling Horn/Strobes •2-wire. Red or white. •-40° F to 151° F temperature rate •Field selectable candela •Plastic weatherproof back box included BK-PC2RK (PC2RK) BK-PC2RHK (PC2RHK) BK-PC2WK (PC2WK) BK-PC2WHK (PC2WHK) SpectrAlert Advance Outdoor Ceiling Strobe SpectrAlert Advance Outdoor Speaker/Strobes •-40° F to 151° F temperature rate •Red or white •Field selectable candela •Plastic weatherproof back box included •-40° F to 151° F temperature rate •NEMA 4X rated. Red or white. •Plastic weatherproof backbox included •“P” suffix plain no-fire printed •Standard candelas: 15, 15/75, 30, 75, 95, 110, 115 •“H” suffix candelas: 135, 150, 177, 185 BK-SCRK (SCRK) BK-SCRHK (SCRHK) BK-SCWK (SCWK) BK-SCWHK (SCWHK) BK-SPSWK/WKP (SPSWK/WKP) BK-SPSRK/RKP (SPSRK/RKP) BK-SPSCWK/WHK (SPSCWK/WHK) Dual Strobe •White amber lens dual strobe plate with "ALERT"/plug-in design/standard candelas SpectrAlert Advance Outdoor Horns •-40° F to 151° F temperature rate. 88dBA horn @ 16VDC. •12 & 24VDC/FWR. Three volume settings. •Plastic weatherproof back box included BK-HRK (HRK) BK-SEPSW (SEP-SW) GET IT NOW! •White amber lens dual strobe with speaker plate with "ALERT"/ plug-in design/standard candelas BK-SEPSPSW BK-SEPSWP (SEPSW-P) •White clear lens strobe with Plain/plug-in design/standard candelas BK-SEPSPSWP (SEPSPSW-P) •White clear lens strobe with speaker plate Plain/plug-in design/standard candelas 168 For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! & Accessories FIRE Sync-Circuit Module •Works with SpectrAlert Advance horns, strobes, horn/strobes, chimes, chime/strobes and mini horns •2 wires to horns, strobes and horn/strobe combo •Horns sync to temp 3 •3 year warranty BK-MDL3R (MDL3R) BK-MDL3W (MDL3W) SpectrAlert Advance Surface Mount Back Boxes •For SpectrAlert indoor devices •Available in red or white •For surface mount applications BK-SBBW (SBBW) BK-SBBR (SBBR) BK-SBBCW (SBBCW) BK-SBBCR (SBBCR) SpectrAlert Advance Weatherproof Plates •Flush mount outdoor plates for horns, strobes, and horn/strobes BK-WTP (WTP) BK-WTPW (WTPW) GET IT NOW! •Flush mount outdoor plates for speaker and speaker/strobes •Only for use with SpectrAlert Advance–R outdoor replacement models •NEMA 3R rated BK-WTPSP (WTPSP) BK-WTPSPW (WTPSPW) Colored Lenses •Wall or ceiling; outdoor rated to -46° F to 151° F •UL 1638 listed •Easy to install to any indoor or outdoor SpectrAlert Advanced strobe device •Applications include emergency communication, severe weather emergency response, amber strobe and more •Red, amber, blue and green colors BK-LENSA (LENS-X) BK-LENSAC (LENS-XX) SpectrAlert Advance Speaker/Strobe Accessories •Retrofit plate •9.5" x 7.5" for retrofit applications •Fits footprint of legacy SpectrAlert speaker strobes BK-RFPW (RFPW) BK-TRW (TRW3) •Trim ring •Optional accessory to provide additional space in back box 120VAC Adaptor Mounting Plate •Operates at 120VAC •Indoor/outdoor use •Compatible with all 2-wire SpectrAlert Advance devices •Plug-in design BK-MP120K (BK-MP120K) BK-TRCW (TRCW) •Ceiling •Red or white For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 169 FIRE Notification Appliances & Accessories SpectrAlert Advance Ceiling Speaker Strobe •White ceiling-mount speaker strobe with clear lens BK-SPSCW (SPSCW) SpectrAlert Advance Horn Strobe •Red strobe •Fire markings •Clear lens BK-P2RK (P2RK) SpectrAlert Advance Strobe BK-SR (SR) GET IT GET IT SpectrAlert Advace Speaker Strobe •White •Wall-mount strobe •Fire markings •Clear lens GET IT NOW! SpectrAlert Advance Horn Strobe NOW! SpectrAlert Advance Ceiling Strobe •White •Ceiling-mount strobe •Clear lens •Red •Ceiling-mount horn strobe •Fire markings •Clear lens BK-PC2W (PC2W) GET IT NOW! SpectrAlert Advance Horn Strobe •White •Ceiling-mount horn strobe •Fire markings •Clear lens SpectrAlert Advance Speaker Strobe BK-SPSR (SPSR) BK-SPSW (SPSW) GET IT NOW! •Red •Wall-mount speaker strobe •Fire markings •Clear lens •White •Wall-mount speaker strobe •Fire markings •Clear lens BK-SW (SW) GET IT NOW! NOW! BK-SCW (SCW) BK-PC2R (PC2R) GET IT NOW! 170 SpectrAlert Advance Strobe •Red •Outdoor •Horn strobe GET IT GET IT NOW! NOW! For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! Notification Appliances & Accessories – Voice Evacuation FIRE End-Of-Line Relay Duster •End of line supervision relay Wheelock SAFEPATH Voice Evac System •Clean away dust and contaminants •Clear away smoke alarm testers •100% non-flammable •Safest choice for energized equipment •Moisture free BK-EOLR1 (EOLR-1) •Supervised Emergency Voice Evacuation, Paging, Messaging, and background music system •40 Watts supervised audio power. 8 digitally records •Speaker outputs: 25V or 70.7V power limited WH-109929 (SP40S) T8-167110S (1671-10S) GET IT GET IT NOW! Voice Evac Panels •Include mic, DMR, amplifier, power supply,battery charger. Speaker circuits 25/70V field selectable. •4 or 8 zones optional. Evac & auxiliary messages built-in. EV-EVAX25 (EVAX 25) •25 Watt NOW! Voice Evac Panels •Include mic, DMR, amplifier, power supply, battery charger. Speaker circuits 25/70V field selectable. •8 to 16 zones optional – Remote microphones available. Evac & auxiliary message built-in. •Four minutes message capacity & optional input cards for up to 64 additional messages EV-EVAX50 (EVAX 50) EV-EVAX150 (EVAX 150) EV-EVAX100 (EVAX 100) EV-EVAX200 (EVAX 200) Intelligibility Meter for Fire Evacuation Systems Emergency Voice System FACP •50 Watt •100 Watt •Complies with Code NFPA, Se. 4-3.1.5 (IEC) Standard 60268-16 •Measures STI and CIS plus Sound Pressure Level •Computer Interface to make reports or modify for noise GO-DSP2B GO-DSP2BKIT •Includes TALKBOXX to insert STI-PA CD into building control rooms •150 Watt NEW Mass Notification System •50W expandable to 1100W •Up to 14 recorded messages •True seamless integration with Fire-lite panels •Modular design for max. sys flexibility and expansion FL-ECC50BDA (FL-ECC50) •200 Watt •Integrated addressable fire alarm with emergency voice system •Up to 792 fire alarm points using SK protocol •Up to 500 Watts using 50W or 125W distributed amplifiers •Meets UL 2572 emergency communication system requirements Intelligent 50 Watts Internal Amplifier •Amplifier for use with the SK-5820XLEVS •UL listed for 520 Hz signaling •25 Volt or 70.7 Volt operation •UL 2572 Listed SK-EVSINT50W (EVS-INT50W) SK-5820XLEVS (5820XL-EVS) For orders, call 800-233-6261 | For system sales and support, call 800-234-7971 | adiglobal.com/us Get It Now! 171 EDUCATION Fire Protection & Safety Do You Have the Right Protection for your Educational Facility? Get The Hands-On Service You Deserve! Determine the Educational Facility Size Pre-School or Day Care Facilities Operators & employees must realize that the occupants will not be able to assist in their own self-preservation. » Fire protection features are based on the size of the facility » In some cases, there may be no, or limited, code-required protection » Some facilities may be a converted, or occupied residence Elementary Schools Some students may be able to assist in their own self-preservation, but this cannot be considered when designing and installing fire protection. However, at this age, they may be able to understand and follow assignments. » Simplicity is key » Ability of occupants may be inconsistent Content provided by: High Schools & Colleges These facilities offer more complex and physically larger challenges as they can be a campus environment with more area, more occupants, language barriers and different cultures represented. » Concerned with early detection of developing emergency conditions » Real-time mass notification of the occupants is essential » Students know their surroundings and can assist in their own self-preservation Get Started » What tools are needed to detect a problem, keeping in mind that fire is not the only issue? » In many settings, consideration has to be given to protecting the fire protection system from the occupants – how can this best be accomplished? » What is the most effective way to notify all of the occupants? » What is the message or messages that have to be communicated in an emergency? » What is the best way to notify emergency responders? Other Issues to Consider » Different types of spaces – classrooms, auditoriums, gymnasiums, living areas » Code requirements in place when the structure was built » Local jurisdictional requirements » Size of the structure Requirements are Based on BOTH Fire Codes and Policies Set by the Owners » Protection requirements have to be made on a building-by-building basis » Changes & alterations need to be closely monitored » Historical value should be considered What to Consider: » Is it a single structure or large campus » Size and construction » Variety of occupants: children & adults » Do you need mass notification capabilities Sponsoring Manufacturers: RETAIL Fire Protection & Safety Is your Retail Space Fire Protected, or In Need of an Upgrade? Get The Hands-On Service You Deserve! Fire Protection & Life Safety solutions should be installed in all types & sizes of retail environments. » Education & training of employees is a must » Protect your investment Whether you have a large retail operation, medium sized or small establishment, fire protection & life safety should be priority number one. Are You a Medium Retail Operation? » Fire alarms & protective signaling systems » Smoke detection systems » Life safety systems » Sprinkler systems ...AND More! » Carry out your corporate mission (Strip Mall or Specialty Store) There May Be Some Challenges for Fire Protection and Life Safety High Tenant Turnover Can Create Additional Challenges » Are fire alarm & other systems still Are You a Large Retail Ope- code compliant for next tenant ration? Fire Protection & Life Safety Needs May Be More » Do space changes cause issues with fire protection systems Complex Unique Hazards » Large space; may include retail racks sometimes at heights up to 20 ft. » Significant travel distances to exits & fire protection components » Variation in commodities What’s Important » Protect your investment Content provided by: » Is the owner of the strip mall mindful of these factors; what is their knowledge of code requirements What’s Important » Fire protection will be aligned with the base of the building, & then the spaces occupied by tenants » Changes need to be closely monitored » Systems must be simple and flexible Find out what kind of protection you need from a Certified Fire Professional. Fire Systems can include: - Addressable & conventional fire systems - IP communications - Heat & flame detectors - CO & gas detectors - Fire communicators - Annunciators - Smoke alarms - Smoke detectors - Pull stations - Notification devices - Speakers - Strobes - Power & surge protection - Smoke emitters - Relays - Test equipment - Protective covers - Voice evacuation - Mass notification - Sprinkler systems - Emergency lights Sponsoring Manufacturers: HOSPITALITY Fire Protection & Safety Do You Have the Right Protection for your Hotel, Restaurant, Nightclub or Theater? Get The Hands-On Service You Deserve! Fire Protection Trends & Issues for Hospitality Occupancies Size of the Facility Must Be Considered! With life safety of large crowds in mind, it’s important to consider the purpose of hospitality facilities in fire protection design: Small Facilities » » » » » » Restaurants and lounges Private and country clubs Ballroom and banquet facilities Hotels and motels Theaters Arenas and stadiums » Nightclubs and concert venues Most hospitality locations are all considered assembly spaces. Code requirements are determined by facility size, number of occupants, and the building’s construction, design and materials. Other important matters of fire protection: » Potential loss of property and income » Facility security and its integration with fire protection systems » Staff training for those responsible for fire systems Content provided by: » Occupants are closer to exits and communications » Evacuation procedures are simpler » Less fire protection may be required » Fire systems are easier to operate and manage Large Facilities Special needs due to: » Food service areas with hood suppression system requirements » Larger administrative and management spaces » Transient residential spaces such as sleeping rooms » Mechanical spaces with operational equipment » How will these areas be arranged and protected? » Will occupants not specifically involved with the emergency be notified? What can be Expected of Emergency Responders? In any of these cases, emergency responders are important in making some of these decisions: » What is their standard emergency procedure? » What is the expected response to an emergency? » Will there be any special requirements of the responders? » What, if anything, would enhance their ability to communicate in a large building? » In addition, has the jurisdiction developed any special requirements for these locations? For these larger buildings, some questions must be considered: » Will occupants evacuate totally to safe harbor outside or inside the building? Sponsoring Manufacturers: HEALTHCARE Fire Protection & Safety Do You Have the Right Protection for your Healthcare Facility? Get The Hands-On Service You Deserve! Trends & Issues for Fire Protection in Healthcare Occupancies Because of differences in structures and purpose served by healthcare facilities, it is useful to categorize them for fire protection: » Small outpatient clinics » Long term care, such as nursing homes » Hospitals of dif. sizes & the units within, • Specialized care units • Surgical suites • Patient records • Patient care areas • Administrative spaces • Mechanical spaces Main objective of any fire protection system is life safety, but there are other important objectives to consider » Hospitals have a critical mission that must be protected » The property, structures and utilities, must be protected for the facility to fulfill its mission » Facility security must be part of the program, and this means protection for the fire protection systems Content provided by: » Staff training, understanding and the ability to interface with fire protection systems is necessary Many people in long term facilities will be non-ambulatory, and incapable of self preservation. There can be several types of They will need to be: people in a healthcare facility » Evacuated by staff to safe harbor outside at any given time the building » Caregivers » Those to whom care is provided » Visitors Size of the Facility Must Be Considered! Small Clinics » Occupants in clinics are not able to roam as they would in a larger hospital » Exits and evacuations are more easily managed » Staff can more easily assist occupants in an emergency » Simpler fire protection systems are provided in most cases Different Space Categories » General patient care areas » Extended patient care for those with special needs » Assembly areas or day room » Relocated by staff to different parts of the building » Kept totally under supervision during the emergency Emergency signaling system must be more than a fire alarm system, and signals need to be passed to staff and other emergency responders Things to Consider: » Coded messages only understood by the staff may be necessary » Prearranged coded phrases over the PA system; Coded light signals » Pagers, radios and other private notification means may be useful » Language barriers can be a problem in diverse areas Sponsoring Manufacturers: TRANSPORTATION Fire Protection & Safety Do You Have the Right Protection for Your Train Station, Subway, Airport, Terminal or Cruise Ship? Get The Hands-On Service You Deserve! Trends & Issues for Fire Protection in Transportation Occupancies Recent innovations in transportation-related fire alarm & emergency notification technology offer tremendous advances in potential fire emergencies and traveler notification. Transportation occupancies, especially those used by the public such as airports, train stations & subways, present unique challenges: » Large numbers of potentially confused or panicked occupants in crowded spaces » Transient occupants; the crowd is always in motion » Travelers focused on the areas of interest such as their boarding gate » Those unfamiliar with their overall surroundings » Language barriers » A mix of occupancies such as restaurants & shops » Behind-thescenes spaces such as mechanical & baggage handling operations Emergency Communications Are Critical The need to transmit emergency information rather than generic signals is now widely recognized. Emergency Voice Evacuation Systems and other Mass Notification Systems (MNS) are becoming widespread to manage complex evacuation instructions and provide egress for large crowds in situations such as: » Terroristic threats - transportation hubs are attractive targets » Severe weather such as tornados » Accidental & intentional release of hazardous materials 4 Tiers of Mass Notification Systems: Tier 1: Immediate & Intrusive » Sirens » Indoor/outdoor loudspeakers » Voice evacuation system » Electronic signage Tier 2: Personal Alerting » SMS text messaging Content provided by: » » » » Computer & wireless pop-ups Tone alert radios Email broadcasts Automated voice dialing Tier 3: Public Alerting » Satellite/AM/FM radio broadcasts » Cable/satellite/off-air television broad casts Tier 4: Locally Relevant Alerting » Handheld bullhorns » Two-way radios Multi-Layered Approach Emergency notification systems should be redundant; no single means of communication should be relied upon to reach everyone affected. Additional planning and engineering can employ new fire protection capabilities ideal for underground passages commonly found in terminals. In the past 10 years, new fire protection design tools have been developed to address more effectively the evacuation of occupants, smoke and ventilation management and emergency lighting. Sponsoring Manufacturers: INDUSTRIAL Fire Protection & Safety Do You Have the Right Protection for your Industrial Facility? Get The Hands-On Service You Deserve! Highly Protected Risk Facilities Regardless of its size, if a facility is considered a “highly protected risk,” more fire protection features may be required: » Properly designed sprinkler protection for the occupancy and hazards within the structure » Built-in passive fire protection features, such as fire-rated barriers and penetration seals » Adequate fire alarm and security services » Concerned management that provides adequate protection including fixed emergency plans » No external exposures that can cause a loss in the insured structure » Adequate and trained emergency services response from in-facility teams, public or private emergency response organizations Protective Signaling Systems Building occupants & emergency responders must be notified of an emergency, and this may be accomplished using a protective signaling system. Content provided by: » In many locations, a system of audible & visible devices, such as horns, bells and strobes, will meet the notification requirements » Where hearing protection is required, additional visible notification is needed » A well thought out design considers all aspects of signal transmission and occupant notification » In larger facilities, various levels of mass notification may be needed rather than one universal signal to evacuate Mass notification systems for manufacturing & industrial facilities will often rely on immediate & intrusive components, such as: » » » » Sirens, horns, etc. Indoor/outdoor loudspeakers Voice evacuation system Increased visible signaling, such as electronic signage throughout the building Scenarios to Plan For In an industrial facility, an emergency plan should be tailored to the threats that can impair operations including: » Fire & associated perils such as explosions » Terrorist threats – in particular to nuclear power facilities » Severe weather such as tornadoes » Complex evacuation including employees in large buildings with many obstructions to egress » Safe, orderly shutdown of operations so that any unattended processes do not contribute to the problem » Early detection & response to hazardous materials released into the environment accidentally or intentionally OSHA & Other Requirements The Occupational Safety & Health Administration (OSHA) and similar organizations require plans to keep the workplace safe. Employees must be protected in the following operations or circumstances: » Welding & other hot work operations » Hazardous material spills & cleanups » Fire fighting & similar operations as part of employees’ normal function » Safe handling of materials such as radioactive waste Sponsoring Manufacturers: COMMERCIAL Fire Protection & Safety Do You Have the Right Protection for your Building? Get The Hands-On Service You Deserve! Fire Protection Trends & Issues for Large Commercial Occupancies The practice of reducing fire risk in large commercial facilities for decades has proven to reduce the number of deaths, injuries & property loss from fires. Today, the use of fire protective systems is much greater in high-rise office buildings than in smaller structures. This prevalence of robust fire protection is credited with the lower rate of fire deaths & property damage in high-rises than in smaller structures. Large commercial spaces can house a variety of operations & occupancies: » High rise office & residential buildings » Large multi-screen movie theaters » Warehouses for non-public storage uses such as groceries » Leasable spaces for non-specified occupancies » Data centers » Business parks with shared spaces » Repurposed industrial sites, such as old Content provided by: mill buildings converted to open, shared retail spaces » Research & technology centers for industries such as drug or weapons development Structure & Tenant Considerations One of the biggest challenges of commercial occupancies, such as industrial parks, is that the type of prospective tenants is usually not known at the time of construction. When the building has no specific tenant in mind, several questions need to be considered: » What types of occupancies does the owner allow? » Are automatic sprinklers needed? If so, what design? » Will a protective signaling system be required? » What will need to be included in the design? » What will be universal enough to fit any anticipated occupancy? Is the building’s structure suitable for commerce that will take place in the space? a wooden structure Simplicity is Key Fire protection features must match the characteristics of the larger commercial spaces. Because of the varying nature of the occupancies, and the fact that many locations will have constant changes in tenancy, keeping fire protection as simple as possible is key. Risk Analysis Designers experienced in mass notification should analyze the risks in large commercial facilities, taking into account the wide variation in the characteristics of commercial occupancies. An objective risk analysis must include: » Size of the structure » Locations for “areas of refuge” » Protection of circuits and & pathways that transmit signals » Message content » Message intelligibility » For example, a paper manufacturing or storage operation can’t be located in Sponsoring Manufacturers: